QUICK START GUIDE
1 Carefully unpack box and make sure you have all of the components shown below.
What’s what?
Important components labeled
1 of 4
Model 16-X1Plus
Unit shown with front panel fully open.
Internal wiring not shown for clarity.
Ascent Unit 12-V AC/DC Adapter
(PS-12DC1)
Key r
IMPORTANT!
We recommend mounting Ascent on a gooseneck pedestal using included hardware.
If using alternate mounting, two (2)
Ascent 10' Cable Extension (p/n 16-X-EXT) products should be purchased and installed.
Failure to do so may result in NO SIGNAL!
2
Carriage Bolt
( x4 )
Hex Nut
( x4 )
Unlock and open front panel of unit for wiring and setup.
r
IMPORTANT!
Ascent WILL NOT WORK until the activation process is COMPLETE !
Follow the Activation Guide or call
Summit Control at (844) 259-8265 to activate your unit.
Continued on next page...
WARNING!
AUTOMATIC GATES CAN CAUSE
SERIOUS INJURY OR DEATH!
ALWAYS CHECK that the GATE PATH
IS CLEAR BEFORE OPERATING !
Reversing or other safety devices should ALWAYS BE USED !
Antenna Cables
Wiegand Device Terminals
For wiring to Wiegand-compatible devices.
See summitcontrol.com/resources .
Status and Event Terminals
For wiring to check gate status and for request-to-exit devices. See Page 3 .
Power and Relay Terminals
For wiring to power and gate operator and/or door opener. See Page 2 .
Relay Status LEDs
Relay is active when lit
Ascent Camera
For automatic and on-demand photo capture
SIM Card
If you have your own SIM card, see Page 4 and follow the instructions entitled,
Installing a Third-Party SIM Card .
CAUTION!
Please use all four screws when mounting unit to pedestal. Leave “hockey puck” antenna in place, even if using extension. Seal any holes or gaps created in unit enclosure.
Failure to follow these instructions can result in damage to the unit!
3
Connect wires
Feed wires through back of unit and connect as shown.
Additional wiring diagrams can be found on Page 3 .
QUICK START GUIDE
Ascent Power and Relay Terminals
12–24 VAC/DC
POWER RELAY A RELAY B DIGITAL INPUTS
J3 J4 J5 J8 J9 J12
2 of 4
Model 16-X1Plus
Gate Operator / Door Opener
12–24 VAC/DC
POWER
12-V AC/DC Adapter
(Model PS-12DC1 included)
The GROUND terminal is optional unless required by local code(s). If using, please connect to earth ground or equivalent.
OR
+ –
Third-Party 12–24-VAC/DC
Power Source
4 Close and lock front panel.
STOP!
Before going forward, double check wiring and ensure unit has power!
For additional wiring options, see Page 3 .
© 2017 Security Brands, Inc. All rights reserved.
Relay B can be wired to a second device in the same manner.
CAUTION!
If you will not be using the 12-V AC/DC adapter, please go to Page 4 and follow the procedure,
Using a Third-Party Power Source .
Do not exceed 24 VAC/DC! Failure to choose a compatible power source can damage unit!
5 Make sure gate path is clear, then key in temporary code
2012
on keypad and con fi rm gate opens.
2 0 1 2
Adding and deleting codes is done through
Summit Control and NOT from the keypad!
N
INSTALLATION COMPLETE!
Now follow the Activation Guide to create an account and begin using Ascent.
QSG-16X1P-EN Rev. B (10/2017)
QUICK START
A
Status Check
Wiring to enable Gate Status Check
GUIDE
B
Event Input
Wiring for accessories such as a request-to-exit device
3 of 4
Model 16-X1Plus
Ascent Status and Event Terminals
GATE 1 GATE 2 EVENT
J7 J13 J6
Ascent Status and Event Terminals
GATE 1 GATE 2 EVENT
J7 J13 J6
Optional wire splices
Gate Operator
N/C
N/O
COM
N/C
N/O
COM
Close Limit Switch
Open Limit Switch
(if equipped with limit switches)
Request-to-Exit
( Summit Access Control S-RTE-P is shown)
Using a
Third-Party
Power Source
(Optional)
QUICK START r
IMPORTANT!
If you would like to use a third-party power source, such as solar, verify that it conforms to the following specs:
Input
Current Draw
12–24 VAC/DC no more than 10% beyond this range less than 90 mA @ 12 VDC less than 60 mA @ 24 VDC
3a
GUIDE
Connect wires to unit as shown in
Step 3.
3b Connect wires to your power source, making sure you connect positive to positive and negative to negative.
4 of 4
Model 16-X1Plus
CAUTION!
Double check that you’ve wired from positive on Ascent to positive on your power source and negative on Ascent to negative on your power source.
Reverse polarity can damage Ascent!
2 Remove existing SIM card and locate new SIM card.
3 Insert new SIM card until it locks in place with “click” sound.
Installing a
Third-Party
SIM Card
(Optional)
1 Push existing SIM card in until it unlocks with “click” sound.
?
NEED HELP
Call (844) 259-8265
Text (720) 386-4627
Email [email protected]
We are available Mon–Fri / 8am–5pm Central
© 2017 Security Brands, Inc. All rights reserved.
QSG-16X1P-EN Rev. B (10/2017)
Advertisement