Atlona OmniStream R-Type AT-OMNI-512 Installation Manual

Add to My manuals
8 Pages

Atlona OmniStream R-Type AT-OMNI-512 is a high-performance networked AV encoder designed for flexible distribution of AV content over Gigabit Ethernet in various applications. It features dual independent channels, each supporting up to UHD @ 60 Hz and HDR with embedded audio and RS-232 or IR control pass-through. Its visually lossless compression ensures pristine video and graphics quality, while its low sub-frame latency makes it ideal for demanding applications like gaming.

advertisement

Atlona OmniStream R-Type AT-OMNI-512 Installation Manual | Manualzz

Installation Guide

AT-OMNI-512

OmniStream R-Type Dual-Channel Networked AV Encoder

AT-OMNI-512

The Atlona OmniStream™ R-Type (AT-OMNI-512) is a networked AV encoder with two independent channels of encoding for two HDMI sources up to UHD @ 60 Hz and HDR, plus embedded audio and RS-232 or IR control pass-through. It is part of the OmniStream R-Type

Series , designed for high performance, flexible distribution of AV over Gigabit Ethernet in residential and light commercial applications. The OmniStream 512 is HDCP 2.2 compliant and ideal for the latest as well as emerging UHD and HDR sources. It features visually lossless compression with pristine-quality video and graphics performance, plus extremely low, subframe latency from encode to decode – critical for demanding applications such as gaming.

This dual-channel encoder is housed in a half-width rack enclosure and is ideal for high-density, compact installation in a centralized equipment location.

Package Contents

1 x AT-OMNI-512

1 x Push spring connector, 6-pin

1 x Wall/table mounting brackets

4 x Rubber feet

1 x Installation Guide

Operating Notes

• OmniStream R-Type uses mDNS as the discovery mechanism. In order for mDNS to function properly, there must not be restrictions applied to the network.

IMPORTANT : Visit http://www.atlona.com/product/AT-OMNI-512 for the latest firmware updates and User Manual.

1

Installation Guide

AT-OMNI-512

Panel Descriptions

1 2 3 4 5

R -

-

T

YPE

YPE

PWR

PWR

O

MNI

MNI S

TREAM

TREAM

TM

TM

1

1

HDMI

HDMI

2

2

1

1

LINK

LINK

2

2

ID

ID

1

1

AT-OMNI-512

AT-OMNI-512

HDMI IN

HDMI IN

2

2

1

1

ETHERNET

ETHERNET

2

2

RX TX

RX TX

RS-232 / IR

RS-232 / IR

1

1

2

2

DC 48V

DC 48V

6 7 8 9

1 PWR

This LED indicator is green when the unit is powered.

2 HDMI 1 / HDMI 2

These LED indicators show the active input status.

3 LINK 1 / LINK 2

These LED indicators show the link status of the encoder.

4 ID

Press this button to identify the unit within the AMS software.

5 REBOOT

Use a pointed object to press this recessed button and reboot the unit.

6 HDMI 1 / HDMI 2

Connect HDMI cables from these ports to

UHD/HD sources.

7 ETHERNET 1 / ETHERNET 2

Connect Ethernet cables from these ports to the Local Area Network (LAN).

8 RS-232 / IR

Use the included captive screw connector to connect an automation system and an IR emitter or extender. Refer to RS-

232 and IR , on the next page for more information.

9 DC 48V

Connect the optional 48V DC power supply to this power receptacle. This power supply is available, separately.

2

Installation Guide

AT-OMNI-512

RS-232

The AT-OMNI-512 provides RS-232 over IP which allows communication between an automation system and an RS-232 device. This step is optional. Either the top three or bottom three set of terminals can be used for RS-232.

1. Use wire strippers to remove a portion of the cable jacket.

2. Remove at least 3/16” (5 mm) from the insulation of the RX, TX, and GND wires.

3. Insert the TX, RX, and GND wires into correct terminal on the included push spring connector, following the wiring diagram below. If using non-tinned stranded wire, press the orange tab, above the terminal, while inserting the exposed wire.

NOTE: Typical DB9 connectors use pin 2 for TX, pin 3 for RX, and pin 5 for ground.

On some devices, the function of pins 2 and 3 are reversed.

Push tab to unlock

TX

RX

GND

IR

The same port that provides RS-232 connections also supports either an IR extender or IR emitter. This step is optional. Either the top three or bottom three set of terminals can be used for RS-232.

1. Use wire strippers to remove a portion of the cable jacket.

2. Remove at least 3/16” (5 mm) from the insulation from each of the two wires.

3. Insert the wires into the correct terminal on the included push spring connector, following the desired wiring diagram below.

IR emitter configuration IR extender configuration

GND

Control

Unit

SIGNAL (white/black)

SIGNAL (white/black)

GND (black)

IR emitter TX out

GND (black)

RX TX GND RX TX GND

IMPORTANT : The IR emitter must be placed no more than 1” from the IR sensor on the device, in order to function properly.

3

Installation Guide

AT-OMNI-512

Installation

1. Connect an Ethernet cable from the ETHERNET 1 and ETHERNET 2 ports on the encoder to a PoE-capable switch on the Local Area Network (LAN). Note that if a PoE-capable switch is not available, the 48V DC power supply (sold separately) must be connected to the encoder.

2. Connect an HDMI cable from each HD/Ultra HD source to the HDMI 1 and HDMI 2 ports on the encoder.

3. If using RS-232 and/or IR, connect the 6-pin captive screw connector to the RS-232 / IR port on the encoder.

4. The PWR indicator, on the front panel, displays the power status of the encoder. When the encoder is powered, using either PoE or the optional 48V DC power supply (not included), the LED initially turns red. After a few moments it will turn amber, and finally green.

R T YPE

PWR HDMI

1 2

LINK

1 2

ID

O MNI S TREAM TM

PWR indicator

RX TX

1

IP Configuration

1

HDMI IN

2 1 2

2

ETHERNET RS-232 / IR DC 48V

The AT-OMNI-512 is shipped in DHCP mode. If a DHCP server is not found within 60 seconds, the unit will automatically be placed in Auto IP mode and will be assigned an IP address within the range 169.254.xxx.xxx

. If this occurs, a static IP address can be assigned to the encoder, allowing it to be access on the network.

1. Disconnect the AT-OMNI-512 from the network.

2. Make sure that the encoder is powered. Power will need to be supplied either by the external 48V power supply (not included) or by connecting an Ethernet cable, from either

ETHERNET 1 or ETHERNET 2 , to a PoE-capable switch.

3. Connect an Ethernet cable from the PC, to the other unused ETHERNET port on the encoder.

4. Click Start > Settings > Control Panel > Network and Sharing Center .

5. Click Change adapter settings .

6. Right-click on the adapter that is used to establish a wired connection to the network, and select Properties from the context menu.

7. Under the Ethernet Properties dialog box, select Internet Protocol Version 4 and then click the Properties button.

8. Click the Use the following IP address radio button.

IMPORTANT : Before continuing, write down the current IP settings in order to restore them, later. If Obtain an IP address automatically and Obtain DNS server automatically are selected, then this step is not required.

4

Installation Guide

AT-OMNI-512

9. Enter the desired static IP address or the IP address provided by the network administrator.

If the PC does not require Internet access or if a statically-assigned IP address is being used, then an IP address of 169.254.xxx.xxx

can be entered.

10. Set the subnet mask to 255.255.0.0

.

11. Click the OK button then close all Control Panel windows.

12. Reconnect the AT-OMNI-512 to the network.

Connection Diagram

Network

Switch

224

OmniStream 512

Encoder

1

HDMI 1

HDMI IN

AT-OMNI-512

2

HDMI 2

Video

ETHERNET

RX

TX

1

2

RS-232 / IR

DC 48V

Video

Ethernet

Ethernet

Ethernet to additional

OmniStream 521

Decoders

Ethernet

Ethernet

Video

Contr ol

R

T YPE

PW

R

O

S TREAM

TM

LINK OmniStream 521

Decoder

Projector

4 media4

Media

Player

Set-Top Box

5

Installation Guide

AT-OMNI-512

Mounting Instructions

The AT-OMNI-512 encoder includes two mounting brackets and four mounting screws, which can be used to attach the unit to any flat surface.

1. Using a small Phillips screwdriver, remove the two screws from the left side of the enclosure.

PW

R

O MNI

S TREAM

TM

5. Repeat steps 1 through 4 to attach the

6. Mount the unit using the oval-shaped holes, on each mounting bracket. If using

HD

MI

2

1 second mounting bracket to the opposite side of the unit.

a drywall surface, a #6 drywall screw is recommended.

1

LINK

2

ID

R -

PW

R

T YPE

1

HD

MI

2

1

O MNI

S TREAM

TM

2. Position one of the mounting brackets, as shown below, aligning the holes on the side of the enclosure with one set of holes on the mounting bracket.

3. Use the enclosure screws to secure the mounting bracket to the enclosure.

Included screws

PW

R

O MNI

S TREAM

TM

HD

MI

2

1

1

LINK

2

NOTE: Mounting brackets can

also be inverted to mount the

unit under a table or other flat surface.

R -

T YPE

ID

4. To provide added stability to the mounting bracket, use two of the included screws and attach them to the two holes, directly below the enclosure screws, as shown above.

6

ID

R -

T YPE

Installation Guide

AT-OMNI-512

Troubleshooting

Problem

PWR indicator is off.

LINK indicator is red.

Solution

• If using a PoE switch, make sure that the port on the switch that is connected to the encoder, has PoE enabled. When the encoder is powered using PoE, the

PWR indicator will be green.

• Check the Ethernet cable for possible damage or loose connections.

• Connect the optional 48V DC power supply (available from atlona.com) to the encoder. When using an external power supply, the PWR indicator will be red.

• The optional 48V DC power supply is connected, but no

Ethernet cables are connected between the switch and the ETHERNET port(s).

• Check the Ethernet cable for possible damage or loose connections.

7

Installation Guide

AT-OMNI-512 atlona.com

408.962.0515

877.536.3976

© 2017 Atlona Inc. All rights reserved. “Atlona” and the Atlona logo are registered trademarks of Atlona Inc. All other brand names and trademarks or registered trademarks are the property of their respective owners. Pricing, specifications and availability subject to change without notice. Actual products, product images, and online product images may vary from images shown here.

8

advertisement

Frequently Answers and Questions

What is the primary function of Atlona OmniStream R-Type AT-OMNI-512?
The primary function of the AT-OMNI-512 is to serve as a networked AV encoder for high-performance distribution of audio-visual content over Gigabit Ethernet.
How many independent channels of encoding does the device offer?
The AT-OMNI-512 offers two independent channels of encoding, allowing for the simultaneous processing of two HDMI sources.
What is the maximum resolution and frame rate supported by the encoder?
The AT-OMNI-512 supports UHD resolutions up to 3840x2160 @ 60 Hz, ensuring pristine-quality video transmission.
Does the device support High Dynamic Range (HDR) content?
Yes, the AT-OMNI-512 is HDR-compliant, enabling the distribution of high dynamic range video sources with exceptional contrast and color reproduction.
What are the connectivity options available for video sources?
The AT-OMNI-512 features two HDMI input ports, allowing for the connection of various HD/Ultra HD sources like Blu-ray players, media players, and set-top boxes.
Does the encoder offer pass-through for control signals?
Yes, the AT-OMNI-512 provides both RS-232 and IR pass-through, facilitating control of connected devices through automation systems or IR emitters.

Related manuals

Download PDF

advertisement