EnviroVent ATMOS Air Specification

Add to My manuals
3 Pages

Envirovent ATMOS Air is a whole-house positive input ventilation system designed to improve indoor air quality and prevent condensation. It features a durable ABS plastic body with DC motor technology and sealed for life ball bearings, ensuring continuous operation at a preset background rate. The unit's synthetic fibre-based filter captures coarse particles, and its 146mm dual inlet forward curved centrifugal fan provides efficient airflow.

advertisement

EnviroVent ATMOS Air Specification | Manualzz

Technical DATA SHEET

ATMOS ® Air | Whole House Positive Input Ventilation Unit

Product

Whole house positive input ventilation system for properties with a loft space, providing ventilation to improve air quality and resolve condensation related problems.

Applications

The ATMOS ® Air unit is manufactured in the UK and installed in properties with a loft space to meet the Building Regulations Approved Document F.

ATMOS ® Air units supply filtered air from the loft space into a central hallway at a continuous rate via a ceiling mounted diffuser, which comes with two blanking plates to maximise efficiency of airflow and is designed to aid in distribution of heat from ceiling level. The unit provides ventilation in order to improve indoor air quality and resolve condensation related problems taking maximum advantage of the benefits of solar gain from within the loft space.

ATMOS ® Air units have an additional facility to draw air from outside during the warmer months when the temperature in the loft space exceeds 25°C.

This provides efficient perception cooling into the property and maintains the required level of ventilation continuously throughout the year.

Installation

A full installation guide is enclosed with all products, or sent separately in advance if required. The unit is pre-wired with a standard length of cable for connection to the 230V mains supply and a low voltage cable for connection to the Auto comfort heater switch. On W and A versions the low voltage cable is reconfigured as a 0-10V input. Duct from the unit to the diffuser is supplied as standard along with a fixing kit.

Annual Running Costs

At speed 1 and 2 the unit will cost less than £6.00 a year to run. Annual running costs are calculated with the comfort heater disabled (All costs are based on an electricity cost of £0.15 per unit (kWh)).

Integral ‘Intelligent’ Comfort Heater

During cold periods, the unit is capable of maintaining the incoming air temperature consistently at 10°C. The integral heater element is manufactured in a solid tubular sheath material.

Controls

At installation the unit will be set by the installer using the integrated control panel to run at one of the 4 fixed speeds (1,2,3, or 4) depending on the size and occupancy of the property. The unit will run continuously all year round on this setting. An integral hours run meter is fitted on all units for monitoring of operational life and verification of usage.

Optional controls:

Model ATL-AIR-W – these units are supplied with a wireless remote control. The user can view the current status of the unit, increase or decrease airflow as required and enable/disable the Auto comfort heater.

Model ATL-AIR-A – these units are app-enabled. Once the user activates the boost switch in the myenvirovent app, the airflow is boosted for 20 minutes as standard before returning to the commissioned setting. Other functions within the myenvirovent app include: Airflow setting, Filter indicator, Hours run meter,

Summer mode control, Auto comfort heater enable/disable.

0-10V variable control input for use with the AIRSENS is available on both W and

A versions.

BBA Performance & Sound levels

Incoming

Air Temp.

(°C)

Fan Speed

Setting

<19

(1)

<25

(2)

1

2

3

4

1

2

3

4

Specific

Fan

Power

(SFP)

0.28

0.26

0.25

0.27

0.14

0.14

0.15

0.18

Airflow

(l/s)

28

35

44

52

22

29

35

43

Power

Usage

(W)

(3)

(as installed figures)

Outlet

Noise dB(A)

@3m

7.9

9.2

10.9

14

5

8

3

4

-

-

-

-

<15

<15

<15

15

1. Above 19°C the unit increases airflow rates per setting by 10%.

2. The unit switches to Summer Mode at air temperatures at or above 25°C.

3. Power usage with Comfort Heater disabled.

Product Codes

Code

ATL-AIR

ATL-AIR-W

ATL-AIR-A

ATL-I*

Description

ATMOS

ATMOS - Wireless Remote Control Unit

ATMOS - App Control Unit

ATMOS Inline

*ATMOS Inline units are a designed specifically for properties with air restricted loft spaces to draw fresh air from outside throughout the year call us on 0345 27 27 810 now to find out more

Technical DATA SHEET

ATMOS ® Air | Whole House Positive Input Ventilation Unit

Construction

Durable ABS plastic body.

Motor

Incorporates DC motor technology with sealed for life ball bearings designed to operate continuously at a pre-set ‘background’ rate.

Fan

Ø146mm dual inlet forward curved centrifugal fan.

Filter

The unit has a synthetic fibre based filter made to ISO Coarse 65%

(G4) in accordance with the ISO 16890 standard.

Servicing / Maintenance

Filter change/inspection is required at 5 years. Various service options are available towards the end of the warranty period. The existing unit may remain in position to ensure minimal disruption. Any old components may be returned for recycling.

Warranty

Covered by a 10 year warranty, subject to the completion of specified maintenance.

Accreditations

Conforms to the requirements of the UK Building Regulations and the

Technical Standards for Ventilation.

Conforms to requirements of the EC directives relating to

Electromagnetic Compatibility and Electrical Safety (EMC and LVD).

CE Marked.

SPARES & ANCILLARIES

Spares & Ancillaries

REPLACEMENT FILTER – UNIT

REPLACEMENT FILTER – DUCT

ENVIROVENT DIFFUSER

AirSens ® CO2*

AirSens ® VOC*

AirSens ® RH*

*W and A units only

Code

FILTER MIVAS

1AC IL FILT ASSY 150

1DIF PIV

AIR-CO2

AIR-VOC

AIR-RH

Unit Dimensions (mm)

Ø1

50

477

Ø197

355

405

525 call us on 0345 27 27 810 now to find out more

Technical DATA SHEET

ATMOS ® Air | Whole House Positive Input Ventilation Unit

Performance Curves

ATMOS ® Air with summer by-pass NOT activated

ATMOS ® Air with summer by-pass activated

Key

3

4

1

2 Performance curve results are measured at free air, based on the unit running below 19°C and exclude ancillaries

A full Consultant Specification can be sent on request.