Netech MiniSim 330 Instruction Manual
Netech MiniSim 330 is a standalone EEG simulator designed for testing EEG recorders and sleep study monitors. It simulates microvolt levels of ABR, sine, triangle, and square waveforms with frequencies ranging from 0.1 Hz to 60 Hz and amplitudes from 10 μV to 2.5 mV. The compact and portable device features a 2-line LCD display, 8-key keypad, and is powered by a single 9-volt battery.
广告
广告
I N S T R U C T I O N M A N U A L
MiniSim 330
E E G S i m u l a t o r
NETECH CORPORATION
110 Toledo Street, Farmingdale, NY 11735 www.NetechCorp.us
Page 2
Dear User,
We appreciate your purchase of the MiniSim 330 EEG
Simulator. Properly used, the instrument will deliver years of high performance and accuracy.
This instruction manual has been designed as a tool to assist you in getting the most from your MiniSim EEG. In order to properly use and to maintain this instrument, please read the manual carefully.
Netech is recognized as an innovative designer and manufacturer of high quality biomedical and industrial test instruments. We are ISO 9001-2015 Certified and fully committed to a continuous improvement process. Further, we guarantee absolute satisfaction with all our products.
Your business is important to us and we are dedicated to providing you with the best customer and technical service possible. Please contact us should you have any questions or concerns regarding your instrument.
We hope you will consider us again when you have a requirement for accurate, reliable, affordable test instruments.
Sincerely,
Netech Corporation
Page 3
Copyright © 2020 by Netech Corporation. All rights reserved.
No part of this publication may be reproduced or transmitted in any form other than for the purchaser’s personal use without written permission from Netech Corporation.
Quality Assurance
Netech Corporation is ISO 9001-2015 Certified. This instrument was thoroughly tested and inspected according to
Netech’s ISO 9001-2015 quality standards (ISO/IEC 17025) and test procedures, and was found to meet those specifications when it was shipped from the factory.
Warranty
Netech warranties the MiniSim 330 EEG for one year from the date of its original purchase against defects in materials and workmanship.
During the warranty period, we will repair or, at our option, replace at no charge, a product that proves to be defective, provided you return the product shipping prepaid to Netech
Corporation. This warranty does not apply if the product has been damaged by accident or misuse, or as the result of service or modification by other than Netech Corporation, or if its serial number is defaced or removed.
Netech reserves the right to discontinue the MiniSim 330 EEG at any time, and change its specifications, price, or design without notice and without incurring any obligation. Netech guarantees availability of service parts for 5 years after the manufacture of the unit is discontinued.
Page 4
The warranty is void if you elect to have the unit serviced and / or calibrated by someone other than Netech.
The purchaser assumes all liability for any damages or bodily injury that may result from the use or misuse of the unit by the purchaser, his employees, agents or customers.
In no event shall Netech Corporation be liable for consequential damages
Trademarks
Netech and MiniSim 330 EEG are trademarks of Netech
Corporation.
Any other trademark names used in this manual are only for editorial purposes and the benefit of the respective trademark owner, with no intention of improperly using that trademark.
Page 5
TABLE OF CONTENTS
0 6
G E N E R A L
D E S C R I P T I O N
0 7
C O N T R O L S &
I N D I C A T O R S
0 8
C A L I B R A T I O N
0 8
S P E C I F I C A T I O N S
0 9
A C C E S O R I E S w w w . N e t e c h C o r p . u s
Page 6
GENERAL
DESCRIPTION
The MiniSim 330 EEG Simulator is a unique stand-alone simulator designed to test EEG recorders and sleep study monitors.
The MiniSim 330 EEG simulates microvolt levels of ABR, sine, triangle, and square waveforms.
The instrument has a 2 line 16 character LCD display and 8 key keypad. It is menu driven via the tactile keys.
The small hand held instrument is powered by one 9 Volt battery.
The MiniSim 330 is CE marked and is shipped with a
Certificate of Calibration traceable to the NIST.
The MiniSim 330 EEG Simulator is a rugged instrument that performs quickly, accurately, and with ease.
w w w . N e t e c h C o r p . u s
CONTROLS &
INDICATORS
1.
On-Off Key.
2.
AC adapter connection.
3.
Left Arrow Key
4.
F1, F2, F3, F4 Function Keys.
5.
Negative lead connectors.
6.
Reference ground connectors.
7.
LCD Display.
8.
Positive lead connectors.
9.
Right Arrow Key
10.
Menu Key:
Page 7 w w w . N e t e c h C o r p . u s
Page 8
CALIBRATION
The MiniSim 330 EEG Simulator is shipped from the factory fully calibrated with a Certificate of Calibration traceable to the NIST. Annual calibration is recommended. Contact the
Customer Service Department for instructions for returning the instrument to Netech for either calibration or repair.
SPECIFICATIONS
ABR Wav eform: 1 KHz, 0.64 μV
Sine, Square, Triangle Waveforms:
Frequencies: 0.1, 0.5, 2, 5, 50, 60 Hz
Amplitudes: 10, 30, 50, 100, 500 μV and 1, 2, 2.5 mV.
Operating Temperature: 15 deg C to 35 deg C.
Storage Temperature: 0 deg Ct o 55 deg C
Accuracy: ± 2%.
Power: One 9 Volt Alkaline Battery.
Weight: 10 oz. (0.28 kg) With Battery.
Dimensions: 5.5 X 3.5 X 1.5 in (14 X 8.9 X 3.8 cm.) w w w . N e t e c h C o r p . u s
ACCESSORIES
Description Part No.
Hard Carrying Case 301
AC Adapter 302
User Manual 330-Manual
Page 9 w w w . N e t e c h C o r p . u s