Aquasure AS-PR75A-BN Owner's Manual
Advertisement
Advertisement
PREMIER SERIES
DRINKING WATER SYSTEM
OWNER’S MANUAL
FOR MODEL NO.
AS-PR50S
AS-PR75A
AS-PR100P www.AquasureUSA.com
818 N Mountain Ave #203c, Upland, CA 91786
800.661.0680 | [email protected]
TABLE OF CONTENTS
4
5
2
2
6
7
INSPECTION & PREPARATION
Be Familiar with the System Before Installation
System Operation Parameters and Installation checklist
Feed Water Adapter with 3/8” or 1/2” Connection Setup
Quick Connect / Compression Fitting Installation Instruction
Drinking Water Faucet Mounting Hole Preparation
13
14
15
16
10
10
12
13
INSTALLING THE SYSTEM
STEP1. Feed Water Adapter Installation
STEP 2. Drain Saddle Installation
STEP 3. Tank Ball Valve Installation
STEP 4. Drinking Water Faucet Installation
STEP 5. Mounting or Placement of the System
STEP 6. Connecting the System
STEP 7. System Startup
18
18
18
19
20
SYSTEM MAINTENANCE
Filter Replacement Time Frame
Removing the FLOWLOK™ Tray
Replacing Stage 1 & 2 Pre-Filters
Replacing Stage 3 & 4 RO membrane and Post Carbon Filter
22 SYSTEM TROUBLESHOOTING
26 LIMITED PRODUCT WARRANTY
Manual Ver 1.0 - 05/2018
You can also visit online for system installation tutorial.
http://www.aquasureusa.com/aquasure-ro-installation-guide-feed-water-adapter/
AQUASURE
PREMIER SERIES 1
WELCOME
Thank you for choosing Aquasure. Before you start using your Aquasure drinking water system, take a few minutes to become familiar with the basics.
Filter replacement
Be sure to change your Aquasure water filters according to the recommended filter replacement schedule. This helps keep your Aquasure drinking water system running in top condition. See page 18
Register your system and extend your warranty
Help experdite any support needed and also receive additional 2 years of limited warranty by registering your system online at http://www.aquasureusa.com/warranty-registration
INSPECTION & PREPARATION
I. Be Familiar with the System Before Installation
IMPORTANT!
Please read the entire manual and become familiar with instructions and parts needed before proceeding with the installation. Hiring a professional plumber who will adhere to all local, state and federal guidelines is recommended for a proper installation.
Inspect the System
Please take the system and all the components out of the box. Inspect the system and all the connection fittings carefully, make sure nothing is damaged during shipping. If any part is cracked or broken, please do not proceed with the installation and contact Aquasure or your distributor for an exchange or diagnosis.
System Components Breakdown (See Dia A)
1. System Cover
2. System Head
3. Stage 1 Sediment Filter
4. Stage 2 Carbon Block Filter
5. Stage 3 Reverse Osmosis Membrane
6. Stage 4 Post Filter
7. Pressurized Water Storage Tank
8. Faucet
9. Flowlok Safety Tray
10. Flowlok Leak Detector
11. ShokBlok Pressure Protection Valve
12. Tank Ball Valve
13. Feed Water Adapter
14. Flow Restrictor
15. Faucet Adapter
16. Color-Coded Tubing
17. Drain Saddle Valve
18. Teflon Tape
Recommended Tool List for System Installation
• Cordless Drill
• Carbide Grinding Burr
• 1/4” (6mm) Drill Bit
• 7/16” (11mm) Drill Bit
• 1/2” (13mm) and 5/8” (16mm) open-end wrenches
(or adjustable)
• Philips screwdriver
• Flashlight or Drop Light
• Protective eye wear (i.e. goggles)
2 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
Dia. A
1
2
7
6 5 4 3
9
10 11 12
8
13 14
15
16
Instruction continues on the next page
17 18
AQUASURE
PREMIER SERIES 3
II. System Operation Parameters and Installation checklist
IMPORTANT!
The following conditions for the feed water supply must be met or warranty will be void and manufacturer assumes no responsibility for damage to system or property.
1. Water Temperature Parameters
• Maximum: 105º F (40.6º C)
• Minimum: 33º F (0.55º C)
WARNING: Do not allow the system to freeze, the membrane always contains water and will be destroyed if frozen. Do not plumb system to hot water, The tubing will expand or burst, and membrane will be destroyed which will void warranty and manufacturer’s responsibility.
2. Water Pressure Parameters
• Maximum: 75 PSI (5.27 kg/cm2)
• Minimum: 40 PSI (2.81 kg/cm2) / 0 PSI for system equipped with electric pump.
WARNING: This system is designed to operate at a water pressure in the range of 40 PSI to 75 PSI
(2.81 kg/cm2 to 5.27 kg/cm2). Operating at a pressure lower than the minimum required PSI will result in lower quality and quantity of product water. Operating at a pressure higher than the maximum allowed PSI will cause severe damage to the system.
WARNING: Do not proceed with the installation until water pressure is confirmed to be lower than 75 psi. A pressure regulator must be installed on the feed water source coming into the home to reduce water pressure going into the system and ensuring water pressure does not exceeds 75 psi.
3. Water Condition Parameters
• Turbidity: <5 NTU
• pH: 4 - 11
• Hardness: < 7 grains per gallon (< 120 ppm)
• Sulfide, Iron Manganese: < 0.01 ppm
• Chlorine: < 2 ppm
• Total Dissolved Solids (TDS): < 1,000 ppm
WARNING: If the hardness of your water is above 10 gpg (171mg/L), lime scale will build up rapidly on the membrane. Scale buildup will plug the membrane and make the system ineffective. We do not recommend this reverse osmosis systems be used with water in excess of 10 gpg (171 mg/L) hardness unless the water is softened prior to the reverse osmosis system.
4. Pre-install environment checklist
• Installation needs to comply with state and local laws and regulations.
• System must be installed indoor away from possible environmental damage
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
• The system is best installed under the kitchen sink. But if that is not feasible, you can install the system anywhere where there is a cold water supply with sufficient water pressure, and an outlet to drain off the rinse water from the system.
4 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
5. System Dimensions & Specifications
IMPORTANT!
Please make sure there is sufficient space for the system to be installed properly. It is best to first place the system in the space to see if there is room for the system to be mounted and installed properly. Do not install the system in an area where it is exposed to extreme hot and/or cold weather or under direct sunlight.
WARNING: It is recommended to mount the system on the wall with the correct screws appropriate for the mounting location. If mounting the system is not an option, please make sure system is installed in a space with secure footing. Improper placement of the system may cause the system to tip over and break due to the added weight of the water.
• System Dimensions: 15”w x 5.25”d x 15”h
• System Weight: 8 lbs (3.6kg)
• Tank Dimensions (with Valve): 11.3”d x 16.75”h
• Tank Capacity: 1.9 - 3.2 gal. (7.2 - 12.1L)
• Tank Weight: 6.6 lbs (Empty) / 40 lbs (Full - Varies by water pressure)
III. Feed Water Adapter with 3/8” and 1/2” Connection Setup
Note: The feed water adapter is setup to work with either 3/8” or 1/2” cold water line. Please make sure the o-ring is properly placed before installation.
1. Converting 3/8” connection to 1/2” (See Diagram B)
• Install the 3/8” to 1/2” outlet converter to the adapter by rotating clockwise until tightened.
• Install the 3/8” to 1/2 inlet converter to the adapter by rotating counter-clockwise until tightened.
Dia. B
Rotate clockwise to tighten
Please make sure there are O-rings inside the connector
3/8” Connection
Rotate counter-clockwise to tighten
Instruction continues on the next page
1/2” Connection
AQUASURE
PREMIER SERIES 5
IV. Quick Connect / Compression Fitting Installation Instruction
Note: This systems is equipped with quick connect fittings. These user-friendly fittings provide superior performance and leak-free seal if installed correctly.
1. Quick Connect Tubing Installation
• Inspect Tubing (See Diagram C-1) - The system comes with pre-cut tubing that is cut cleanly and squarely to ensure proper connection. Please ensure that the tube has a smooth outside diameter without any burrs, chamfers or score marks prior to inserting it into the fitting. Tubing that has not been cut properly can cause drips and leaks
• Insert Tubing (See Diagram C-2) - Push the tubing through the collet and o-rings until it bottoms out against the tube stop.
The collet holds the tube in place and the
O-ring provides a leak resistant seal. If you need to remove the tubing always re-cut before connecting tubing again. Scores on tubing can cause failure.
• Push and pull the tubing toward and away from the fitting to ensure that is installed properly. (See Diagram C-3)
Dia. C-1
Dia. C-2
Tubing Collet
CORRECT
INCORRECT
Quick Connect Fitting
O-Ring Tube Stop
Dia. C-3
2. Quick Connect Tubing Removal
• Release the Tubing (See Diagram B-4)
- Relieve pressure from the tubing and fitting. Push the collet flange against the fitting body while pulling the tubing away from the fitting to release it.
Dia. C-4
IMPORTANT!
Should a leak occur at a fitting, the cause is generally defectively cut tubing. To fix a leak, relieve pressure, release tubing, cut o at least 1/4” from the end (square cut), reattach the tubing and confirm the connection is leak free. Each time a new connection is made, it is advisable to cut off 1/4” from the end of the tubing using these fittings.
6 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
3. Optional Compression Nut Fitting (See
Diagram B-5)
• Slip the compression nut onto the tubing.
• Slide the plastic sleeve onto the tubing
• Place the insert inside the tubing
• Slide the compression nut up and tighten it onto the flange using a wrench.
Dia. C-5
Tube
Nut
Sleeve Insert
V. Drinking Water Faucet Mounting Hole Preparation
IMPORTANT!
Extreme care must be taken in drilling the hole for the dispensing faucet. The surface material of most sinks is extremely hard and brittle and can be easily chipped or cracked. If you are uncomfortable performing the following procedure it is recommended that an experienced plumber is consulted for techniques, installation or other assistance. The system’s manufacturer accepts no responsibility for sink top damage resulting from system installation. Before grinding or drilling put on appropriate eye protection (i.e. goggles) to protect yourself from porcelain or metal chips. EXTREME
CAUTION SHOULD BE TAKEN WITH GRANITE, MARBLE AND LIKE MATERIAL.
WARNING: Many homes are electrically grounded through the plumbing. To protect yourself from serious injury or fatal shock, use a battery-powered hand drill only to make the hole. DO NOT USE AN
ELECTRIC DRILL.
1. Using an Existing Hole
• Spare Hole: If there is a spare hole covered by a rubber or chrome cover, simply remove the cover and install the drinking water faucet at the location.
• Spray Hose: If the spray hose is not in use, remove the hose and mount the drinking water faucet at the location. Remember to plug up the outlet under the main faucet. If the spray hose uses a diverter at the base of the spout, be sure to remove it to avoid trouble later on.
• Hanging faucet: If drilling a hole is not feasible (i.e. rental home, drill tool not available etc.), the faucet can be placed inside the sink cabinet or wherever convenient without mounting.
2. Pre-drilling preparation
• Check under the sink in the area that you plan to install the faucet and make sure that there is ample of room to secure the mounting hardware. A space of approximately 2 inches in diameter is needed.
• REMOVE EVERYTHING FROM INSIDE THE SINK AND SURROUNDING AREA. Place paper towels in the sink to catch the shavings from the grinding and drilling.
• REMOVE EVERYTHING FROM UNDER THE SINK. Place newspaper or paper towels directly under drilling location in order to catch the drill shavings.
3. Drilling Porcelain or Enamel
WARNING: Metal shavings can oxidize and discolor porcelain. Be extrememly careful to cover porcelain sinks. Always wear gloves and protective eyewear when drilling.
• Using a cordless drill with a carbide grinding burr, gently grind away enough porcelain or enamel to more than accommodate the 7/16” (11 mm) drill bit. Approximately the size of a dime. Enough surface material must be removed to expose the base metal.
• Using the 1/4” (6 mm) drill bit, drill a centering or pilot hole in the center of the desired faucet location. It will make it easier for the 7/16” (11 mm) drill bit to cut through the sink
• Switch to 7/16” (11 mm) drill bit and operate the drill slowly and carefully— Especially when the drill bit is about to penetrate the metal. Otherwise, damage to sink may occur. Use lubricating oil to keep the drill bit cool while drilling.
Instruction continues on the next page
AQUASURE
PREMIER SERIES 7
4. Drilling Stainless Steel
• Use a hole punch and hammer to mark the location of where you want to install the faucet. Keep your taps short and control until a dent is visible, this will help keep your drill bit seated when start drilling.
• Apply lubricant to the drill area as drilling at high speed will create a lot of heat which can cause the metal to warp or burn.
• Using the ¼” (6mm) drill bit, at half speed to drill the hole. This would help prevent it from overheating.
• Switch to 7/16” (11 mm) drill bit and do the same to widen the hole.
• Once the hole is drilled, use the file to smooth out the edges and wipe away the shaving.
• Clean The Area
• Discard paper towels and newspaper used in the sink and below sink. Be very careful not to drop any shavings in the sink or on the floor as they will oxidize and stain surfaces very quickly.
8 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
AQUASURE
PREMIER SERIES 9
INSTALLING THE SYSTEM
WARNING!
Do not proceed with the installation until you have gone over the System Operation
Parameters and Installation Checklist section on page 4 of this owners manual and comply with all the conditions listed in that section. Failure to comply may result in property damage and your system warranty will be voided due to non-compliance with the operation parameters.
IMPORTANT!
Locate and test the main water supply valve to the house before installing the system.
If the main water supply valve fails to shut off the water completely during the test, we recommend contacting your local plumber to fixed the valve before begin installing the system.
Scan QR Code Here to get support Faster! Feel free to contact our support at
1-800-661-0680 during our normal business hour of Monday - Friday from 8:30 am to 5:30 pm PDT. You can also email us at [email protected] or visit us on the web at http://www.aquasureusa.com/support for installation assistant or support.
STEP 1. Feed Water Adapter Installation
Locating the Cold Water Supply Valve:
1. Locate the Cold water supply valve under the kitchen sink. Turn off the incoming cold water completely by turning the shut-off handle clockwise.
2. Test to see if the cold water line is completely shut off by turning on the faucet in the cold water position. If cold water cannot be turned off, the main water supply to the house must be shut off for the installation.
Dia. D-1
Connecting with Flex Line Riser: (See Diagram
D-1)
1. Loosen the nut and separate cold water riser tube from faucet shank. Gently bent riser tube so that the feed water adapter fits onto the faucet shank.
2. Attached the feed water adapter to cold water supply valve.
3. Attached the cold water riser to the other side of the feed water adapter. (If necessary, apply 3 to 5 rounds of Teflon tape onto the feed water adapter before attaching the cold water riser.)
Feed Water
Adapter
Riser Tube
Cold Water Line
Shut-off Valve
10 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
Test For Leaks:
1. Make sure the feed water adapter is in the shut-off position, perpendicular to the feed connection (See Diagram D-2)
2. Turn on the cold water supply to the sink faucet.
3. Check for leaks
Note: If there’s a water leak, check the connection and apply more Teflon or tighten the connection more to stop the leak.
Dia. D-2
Optional connection for connecting on Solid Copper Riser with Self-Piercer (Sold Separately): (See
Diagram D-3)
1. Firmly clamp the self-piercer onto the riser tube by adjusting and tightening the lock nut
CAUTION!
Do not overtightened! This will crush and damage the copper riser.
2. Pierce the line by simply screw the T-handle valve clockwise until it stops.
Note: If the hole in the copper tube is not adequately pierced, this may prevent sufficient cold water supply to flow to the system and reduce the system performance. In this event, open and close the self-piercing valve several times to ensure an adequate pierced tube.
Dia. D-3
Instruction continues on the next page
AQUASURE
PREMIER SERIES 11
STEP 2.
Drain Saddle Installation
1. Locate the optimal placement on the drain pipe to install the drain saddle. (See Diagram E-1)
Note: The drain saddle should be installed above the trap and on the vertical or horizontal tail piece. To reduce potential drainage noise, it is ideal to mount the drain saddle as low as possible on the vertical pipe above the trap or on the horizontal tail piece. If the drain saddle is to be installed on the horizontal tail piece, it is recommended to install the drain saddle where the drain tube connection is on top of the horizontal pipe.
2. Mark the position of the hole on the drain pipe and drill a ¼” hole through one side of the drain pipe.
(See Diagram E-2)
Dia. E-1 Dia. E-2
3. There is a piece of self-adhesive sponge gasket provided. Glue this sponge gasket to the inside of the saddle, this will cushion any gap between the saddle and the pipe. Make sure the hole on the sponge is thoroughly punched out and is aligned with the hole on the saddle.
Note: Make sure to align the drain saddle hole to the drilled hole perfectly. Mis-aligning these two holes will block the rinse water and damage the membrane.
4. Attached the drain saddle to the pipe by gently tighten the two screws evenly on both sides of the clamp until the clamp is sung on the pipe. (See Diagram E-3)
CAUTION!
Do not over tighten! Over tightening may cause the drain saddle to break or crush the drain pipe.
Dia. E-3
Make sure the self-adhesive sponge is glued to the saddle
12 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
STEP 3. Tank Ball Valve Installation (See Diagram F-1)
1. Attached the tank ball valve on top of the tank.
CAUTION!
Do Not over tighten the adapter to avoid breaking and leak.
Dia. F-1
STEP 4.
Drinking Water Faucet Installation (See Diagram G-1)
1. Place the faucet base over the drilled hole and make sure the hole is completed covered by the faucet base.
2. Insert the faucet shank through the faucet base and drilled hole completely.
3. From under the sink slip the large, black washer over the faucet shank. Next, slip the lock washer over the faucet shank followed by the thin chrome nut.
4. While holding the faucet assembly above the sink tighten the chrome nut below the sink with an adjustable wrench. Tighten the chrome nut until the faucet assembly does not move.
(A faucet wrench is recommended if the space for proper mounting is very limited)
CAUTION!
Do Not over tighten the adapter to avoid breaking and leak.
5. Attached the faucet adapter to the shank.
Counter
Dia. G-1
Faucet Base
Black Washer
Faucet Shank
Faucet Adapter
Lock Washer
Chrome Nut
Pure Water Line
Instruction continues on the next page
AQUASURE
PREMIER SERIES 13
STEP 5.
Mounting or Placement of the System
WARNING!
If mounting the system is not an option, please make sure system is installed in a space with secure footing. Improper placement of the system may cause the system to tip over and break due to the added weight of the water.
1. Position the system on the wall at the desired mounting location 3 - 4 inches from the cabinet floor to the base of the system. (See Diagram H-1)
IMPORTANT!
Be careful not to kink any of tubing on the system as kinked tubing can rupture and leak.
2. Using a pencil or marker and mark the mounting hole on the back of the bracket onto the wall.
Note: Please make sure the bracket mount is leveled using a level tool to ensure evenly distributed stress on the bracket.
3. Set the system aside.
4. Screw the two screws into the wall at the marked position and make sure there is some protrusion space for the bracket to seat securely.
5. Mount the system onto the screw.
Dia. H-1
We recommend 4” of ground clearance from cabinet floor
to the base of the system
4”
14 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
STEP 6. Connecting the System (See Diagram I-1)
Note: Remove all end plugs from the system by following the fitting-removal instruction on page 6, and please follow the proper fitting installation instruction to prevent any possible leak.
IMPORTANT!
Be careful not to kink any of tubing on the system as kinked tubing can rupture and leak.
1. Connect the WHITE color-coded tubing from the SHOKBLOK protection valve (A) to feed water adapter (B)
2. Connect the BLACK color-coded tubing from drain water connection (C) to Drain saddle (D)
3. Connect the BLUE color-coded tubing from system (E) to Pressurized Water Storage Tank (F)
4. Connect the BLUE color-coded tubing from the system post filter (G) to faucet adapter (H)
Note: if you purchase the optional extra-output kit, please follow to supplied installation instruction first before moving on to the next step.
Dia. I-1
Drain Pipe
Cold water Line
D
H
G
E
C
B
Supply Water Valve
A
Kitchen Counter
F
Instruction continues on the next page
AQUASURE
PREMIER SERIES 15
STEP 7.
System Startup
WARNING! Immediately shut off the cold water supply valve or main water supply valve if there are leaks. Check the leak area and see if there’s a loose connection or if more Teflon tape is needed to prevent leaks from happening.
1. Turn on the feed water adapter valve and cold water supply valve to allow the water to pass through. (See Diagram J-1)
Dia. J-1
3. Turn on the Tank Ball Valve lever parallel to the tubing connection to allow the water to enter the tank. (See Diagram J-3)
Dia. J-3
2. Turn on the FLOWLOK™ valve to allow the water to enter the system. (See Diagram J-2)
Dia. J-2
4. Wait 2 to 3 hours for the water storage tank to fill. The system will automatically shut off once the tank is full.
5. Check for leaks! The system is now filled with water and pressurized.
6. Drain out the first tank of water by turning on the dispensing faucet. Have the water run till it becomes a slow stream of water, or when it starts to trickle. (See Diagram J-4)
Dia. J-4
16 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
Mount the system onto the wall or placed in a secure location.
Turn off the FLOWLOK™ lever and insert the compressed safety disc inside the holder and turn the lever back on. (See Diagram J-5)
Turn off the drinking water faucet to let the water storage tank replenish the product water.
Check one last time on all the connections and joints to make sure there’s no leak.
Dia. J-5
Disc Holder
Safety Disc
CONGRATULATIONS!
You have finished installing your very own drinking water system.
Don’t forget to register your system to get additional 2 years of limited warranty.
Simply scan the QR code using your mobile phone, or go directly to our website http://www.aquasureusa.com/warranty-registration to begin the online registration process.
AQUASURE
PREMIER SERIES 17
SYSTEM MAINTENANCE
Note: The system requires very little maintenance as long as the filter cartridges are regularly replaced at the recommended time frame. Please only use genuine Aquasure replacement filter at http://www.aquasureusa.com/water-filter/drinking-water/premier
Filter Replacement Time Frame
• Pre-Stage Filters: Replace every 6 to 12 months
(Private well water source may need to replace pre-filters sooner than 12 months due to heavy sediments and other particulates.)
• RO-Membrane: Replace every 2 years
(Private well water source may need to replace membrane sooner than 2 year due to lower source water quality)
• Post-Stage Taste Refining Filter: Recommend replacing with the RO-Membrane
CAUTION! Before working on any system maintenance, prepare a clean cloth or microfiber towel to wipe off excess water that might spill during the filter replacements and or system maintenance.
I. Removing the FLOWLOK™ Tray
CAUTION! If the system is equipped with FLOWLOK™ leak detector. The tray must be removed before replacing the filters. Failure to do so may cause the safety disc to expand and trip the auto-shut-off safety lever.
1. Remove the FLOWLOK tray by unscrewing the locking screw behind the filters (See Diagram K)
2. Unseat the tray by lowering it from the filters
Dia. K
18 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
II. Replacing Stage 1 & 2 Pre-Filters
1. Turn OFF tank’s ball-valve. (See Diagram L-1)
Dia. L-1
4. Twist the Pre-Stage Filters quarter turn to the right to unseat the filters from the system.
(See Diagram L-4)
Dia. L-4
2. Turn OFF cold water supply from feed water adapter to the system. (See Diagram L-2)
Dia. L-2
5. Replace the system with new Pre-Stage
Filters by setting them on to the system and twisting them quarter turn to the left. (See
Diagram L-5)
Dia. L-5
3. Turn on drinking water faucet lever briefly to release the water and relief the built-up pressure inside the system. This will make removing of filters easier. (See Diagram L-3)
Dia. L-3
Instruction continues on the next page
6. Repeat the same process for stage 2.
7. Turn ON cold water supply and Tank Ball
Valve.
8. Check for leaks.
9. Secure the FLOWLOK tray by screwing the locking screw behind the filters.
AQUASURE
PREMIER SERIES 19
III. Replacing Stage 3 & 4 RO membrane and Post Carbon Filter
1. Turn OFF cold water supply from the feed water adapter to the system.
2. Turn on the dispensing faucet to empty out the tank and store all the product water in a spare water container for usage.
3. When the water starts to trickle, turn OFF tank’s ball-valve, but leave the drinking water faucet lever on briefly to release the remaining water and relieve the built-up pressure inside the system. This will make removing of membrane easier.
4. Disconnect the black tubing with the flow restrictor from the Elbow Valve. (See
Diagram L-6)
Dia. L-6
5. Twist the RO-Membrane and Post-Stage
Taste Refining Filter quarter turn to the right to unseat the filters from the system.
6. Replace the system with new RO-Membrane and Post-Stage Taste Refining Filter by twisting the filters quarter turn to the left.
7. Make sure the RO-Membrane and Post-
Stage Taste Refining Filter are firmly locked in with the system.
8. Re-attached the black tubing with the flow restrictor on to the Elbow Valve.
9. Turn ON cold water supply from feed water adapter and tank ball valve.
13. Check for leaks.
14. Turn off the dispensing faucet and wait 2 to
3 hours for the water storage tank to fill.
15. Drain out the first tank of water by turning on the dispensing faucet. Have the water run till it becomes a slow stream of water, or when it starts to trickle.
16. Turn off the dispensing faucet to let the water storage tank replenish the product water.
17. Secure the FLOWLOK tray back onto the system.
20 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
AQUASURE
PREMIER SERIES 21
SYSTEM TROUBLESHOOTING
IMPORTANT!
Please shut off cold water supply valve to the system if the system is malfunctioning or leaking and contact our support department immediately!
For any system troubleshooting, feel free to contact our support department at
1-800-661-0680 during our business hour of Monday - Friday from 8:30 am ~ 5:30 pm PDT. You can also e-mail us at [email protected] or visit us on the web at http://www.aquasureusa.com/support for all the latest update and support.
1. Not enough water from holding tank
CAUSE:
A Feed water valve is plugged
B Sediment/Carbon pre-filters or carbon post filter is clogged
C Low incoming water pressure
CORRECTION:
Open valve or unclog the valve
Replace the filters
D Reverse osmosis membrane is fouled
E Air pressure in holding tank is incorrect
F Air bladder in holding tank is ruptured.
G Holding tank valve is closed
Incoming water pressure must be above the recommended psi level. Install a booster pump or permeate pump if water pressure is lower than the recommended level.
Make sure incoming water pressure is within operating limits. Make sure drain line is not clogged and replace the membrane.
Empty water from holding tank. Air pressure in valve stem should be between 5-10 psi.
Replace the holding tank
Open valve
H No water to drain. Drain flow restrictor is clogged
Replace the drain flow restrictor.
I Check valve on RO membrane housing is stuck Replace the check valve.
J The automatic shut-off valve is malfunctioning.
Replace automatic shut-off valve.
2. Taste and odors in product water
CAUSE:
A Carbon post filter is exhausted.
B There is foreign matter in holding tank.
C Product water and drain water lines are reversed.
D Dissolved gases in feed water.
E Increase in product water TDS.
CORRECTION:
Replace the filters
Clean, flush and sanitize the holding tank. Replace filters.
Correct plumbing
Pre-treat feed water to remove gases
See “Product water is high in total dissolved solids” for troubleshoot.
22 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
3. Low water pressure from dispensing faucet
CAUSE:
A Air pressure in holding tank is incorrect. This is the #1 reason for low flow from reverse osmosis system.
B Carbon post filter is clogged
C Holding tank valve is partially closed
D The faucet is out of adjustment of faulty.
E Heavy water use. Holding tank is empty.
F Low water production
CORRECTION:
Open faucet and empty water from holding tank. Shut off feed water to system and remove holding tank from under sink. Locate the air valve stem and add air. If there’s still water in the tank, continue to add air until all the water is removed. Once all the water is removed, continue to add air and pressurize to 8 psi.
Re-install the tank under the sink, turn on the feed water supply to the system and allow the tank to fill.
Replace post filter.
Open tank ball valve fully.
Repair or replace the faucet
Allow holding tank to refill for about an hour or so before using the water.
See “Not enough water from holding tank” for troubleshoot.
4. Drain water overflows at the air gap faucet
CAUSE:
A Air gap is clogged
B Drain line is clogged
C Drain flow rate is too high
CORRECTION:
Clear Air Gap
Clear Tubing
Replace flow restrictor
5. Product water is high in total dissolved solids (TDS)
CAUSE:
A Clogged pre-filters
CORRECTION:
Replace Filter
B
C
Low Incoming water pressure
Reverse osmosis membrane is expanded
Incoming water pressure must be above 40 psi. Install a booster pump or permeate pump
If membrane life is unusually short, check the TDS level of incoming water to see if it exceed the range of recommended operating condition. Pretreatment may be needed if the incoming TDS level is too high.
An average life of membrane should be around 2 - 3 years. Replace the RO membrane
D Product water and drain water line are reversed Check the connection and correct plumbing
Replace drain flow restrictor E No water to drain. Drain flow restrictor is clogged.
F No water to drain. Air Gap faucet is clogged.
G The automatic shut-off is not closing
Clear or replace air gap faucet
Repair or replace automatic shut-off valve
H New carbon post-filter has not been rinsed completely
I The incoming feed water TDS has increased
Drain holding tank twice to rinse new carbon postfilter
An increase in feed water TDS will also give an increase in product water TDS
AQUASURE
PREMIER SERIES 23
6. Faucet leaks or drips
CAUSE:
A Water leaks from faucet spouts
CORRECTION:
Adjust the faucet by turning the tee bar located under the handle to provide a small amount of free play in the handle when shut off. Should this not work, repair or replace the faucet.
Repair or replace the faucet.
B Water leaks from beneath the handle
7. Little to no water at dispensing faucet.
CAUSE:
A Water is shut off at stop valve
B Flowlok is set to off position
C Output line is crimped
D Tank is not pre-charged
E Tank is defective or does not hold pressure
F Tank is not filled with water yet
G Insufficient water pressure
H Incorrect installation
CORRECTION:
Open main stop valve.
Make sure Flowlok main lever is in open position.
Lever should be lowered.
Reroute the line so they are not restricting the water from existing the faucet.
Empty out the tank and recharge the tank pressure
Replace the tank
Allow holding tank to refill for about an hour or so before using the water.
Incoming water pressure must be above 40 psi. Install a booster pump or permeate pump
Check the installation guide and make sure all the steps are installed properly.
8. System makes humming noise
CAUSE:
A Air bubble trapped inside the housing
CORRECTION:
Purge the air by tilting the system on one side, shut off the tank ball valve and turn on the dispensing faucet for about 1 minute. Repeat 3 or 4 time to purge out all the air.
9. Tank takes a long time to fill
CAUSE:
A Insufficient water pressure
B Lower water temperature
CORRECTION:
Incoming water pressure must be above 40 psi. Install a booster pump or permeate pump
Cold water affects the performance of system. Install a booster pump or permeate pump to compensate for lower water temperature.
10. System slow to shut off
CAUSE:
B Feed water valve is not open fully
CORRECTION:
A Insufficient water pressure for system to shut off Incoming water pressure must be above 40 psi. Install a booster pump or permeate pump
Open feed water valve fully to lessen the restricted flow
C Sediment/Carbon pre-filters is clogged Replace the filter
24 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
11. System does not shut off
CAUSE:
A Automatic shut-off valve is defective
B Automatic shut-off valve is not defective and incoming water pressure is too low
C System is feeding multiple outlets or an outlet that demands water constantly.
CORRECTION:
Test the functionality of automatic shut-off valve by closing the tank ball valve to see if the system will shut off. If the system continues producing water, the automatic shut-off valve is defective and needs to be replaced.
Incoming water pressure must be above 40 psi. Install a booster pump or permeate pump.
It is normal in this situation as system needs to constantly produce water to supply the multiple outlets.
AQUASURE
PREMIER SERIES 25
MANUFACTURER’S WARRANTY
1-YEAR LIMITED WARRANTY
For AQUASURE Drinking Water Systems
AQUASURE Drinking Water Systems warrants product to be free from defects in material and workmanship for a period of twelve (12) months from the date of purchase. During this time, we will repair or replace, at its option, any AQUASURE Drinking Water System. Please request and RMA and upon RMA approval return the AQUASURE Drinking Water Systems and we will either make the necessary repairs or, if it is determined that a replacement is required, we will provide a replacement part. This warranty does not include shipping and handling charges which will be collected from you by the dealer. Parts repaired or replaced under this one (1) year warranty will be covered under warranty to the end of the original one (1) year warranty period. This warranty is also subject to the conditions and limitations outlined under the heading “General Conditions and Limitations” section.
ONE-YEAR LIMITED PRORATED WARRANTY
For Structural, Hardware and Electrical Components
AQUASURE Drinking Water Systems warrants the structural, hardware, and any electrical components to be free from defects in material and workmanship for a period of one (1) year pro-rated from the date of purchase. During this time, we will repair or replace, at its option, any defective parts covered by the warranty. Defective part(s) will need to be returned to AQUASURE. We will either make the necessary repairs or, if it is determined that a replacement is required, we will provide a replacement part. We will then return the part to the buyer. This warranty does not include shipping and handling charges which will be collected from you. Parts repaired or replaced under this one (1) year pro- rated warranty will be covered under warranty to the end of the original one (1) year prorated warranty period. This warranty is also subject to the conditions and limitations outlined under the heading “General Conditions and
Limitations” section.
One-Year Limited Warranty for fittings, tubing, valves, flow-lok and shok blok.
AQUASURE Drinking Water Systems warrants these parts to be free from defects in material and workmanship for a period of one (1) year from the date of purchase. During this time, we will repair or replace, at its option, any defective parts covered by the warranty. The warranty may be verified using date codes in addition to purchase receipts and AQUASURE Drinking Water System’s database of serial number sales date. We will advise you whether the defective item needs to be returned to the
AQUASURE Drinking Water Systems dealer you purchased the equipment from for failure analysis.
Replacement parts provided under warranty will be sent to your AQUASURE Drinking Water Systems dealer. Parts replaced under this one (1) year warranty will be covered under warranty to the end of the original one (1) year warranty period. This warranty is also subject to the conditions and limitations outlined under the heading “General Conditions and Limitations” section.
General Conditions and Limitations
None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor scratches or imperfections that do not materially impair the operation of the product.
The warranties also do not cover products that are not installed as outlined in the applicable Owner’s
Manual. AQUASURE Drinking Water Systems System warranty will be deemed null and void if any of the product labels are removed. The limited warranties described above are the only warranties applicable to the AQUASURE Drinking Water Systems products. These limited warranties outline the exclusive remedy for all claims whether based on contract, tort (including negligence), strict liability or otherwise.
Disclaimer of warranties. Except as expressly warranted in writing by, the goods sold by AQUASURE are purchased by the buyer “as is.” AQUASURE does not warrant that the goods are of merchantable quality or that they can be used for any particular purpose. Except as expressly warranted in writing by
AQUASURE, AQUASURE makes no representation or warranty of any kind with respect to the products.
26 www.
AQUASURE
USA .com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
Non-Covered Defects
THIS LIMITED PRODUCT WARRANTY DOES NOT COVER DEFECTS CAUSED BY:
1. Improper storage, installation, maintenance, handling, use and/or alterations of the Product, including, but not limited to, noncompliance with the installation, maintenance and standard operation conditions stated in the Manual and this Limited Product Warranty.
2. Unreasonable use, unintended use, or misuse of the Product for something other than its intended purpose as a drinking water system.
3. Use of replacement parts, filters, membranes or other accessories that are not sold or manufactured by Aquasure for use with this particular Product.
4. Damage not resulting from manufacturing defects that occur while the Product is in the original purchaser’s possession.
5. Installation of the Product with known or visible manufacturing defects at the time of installation.
6. Damage caused by freezing, flood, fire or Act of God.
Condition that render this limited product warranty void
THIS LIMITED PRODUCT WARRANTY SHALL BE VOID IF:
1. The Product is not operated in compliance with normal municipal water conditions for which the particular model of this Product is intended.
2. The person seeking to invoke the warranty is not the original purchaser. That is, this Limited Product
Warranty only extends to original purchasers.
3. The product is purchased used. That is, this Limited Product Warranty only covers new products.
4. The Product is purchased from someone other than Aquasure or one of Aquasure’s authorized dealers. This is because, unless the Product was sold by Aquasure or one of its authorized dealers,
Aquasure cannot verify or guarantee the integrity or authenticity of the Product.
Limitation of liability.
In no event shall AQUASURE be liable to the purchaser or any other entity for more than the invoice price received by AQUASURE for any non-conforming products. AQUASURE shall not be liable to the purchaser or any other entity for personal injury, property damage, or any direct, indirect, special, incidental, consequential, punitive, exemplary, or other damages of any kind, including without limitation the cost of procurement of substitute goods, the loss of profits, products, or production, or the interruption of business, however caused and on any theory of liability, and whether or not AQUASURE has been advised of the possibility of such damages. The essential purpose of this provision is to limit the liability of AQUASURE arising out of the sale of products to the purchaser whether for breach of contract, negligence, or otherwise. These limitations shall apply notwithstanding any failure of essential purpose of any limited remedy and notwithstanding the provisions of any other agreement between
AQUASURE and the purchaser.
Obtaining Warranty Coverage or General Inquiries
If coverage is available, you may obtain coverage under this Limited Product Warranty by providing
Aquasure with proof of original purchase, and that you are the original purchaser. For service under this Limited Product Warranty, you must notify Aquasure by phone at 1-800-661-0680, by email at [email protected], or in writing at 12403 Central Ave #536, Chino, CA 91710. In making the claim, please provide your name, address, phone number, a description of the product involved, and an explanation of the defect.
AQUASURE
PREMIER SERIES 27
GENERAL CONDITIONS AND LIMITATIONS
The products described in this document are hereby offered for sale to be established by Aquasure any of its subsidiaries and its authorized distributors. This offer and its acceptance by any customer (the “Buyer”) shall be governed by all of the following
Terms and Conditions. Buyer’s order for any item described in this document, when communicated to Aquasure, its subsidiaries or an authorized distributor (the “Seller”) verbally or in writing, shall constitute acceptance of this offer. Provided, however, that these terms and conditions shall not operate as a rejection of the Buyer’s offer unless such offer contains variances in the description, quantity, price, or delivery schedule of the items.
1. Terms and Conditions of Sale.
All descriptions, quotations, proposals, offers, acknowledgments, acceptances and sales of the Seller’s products are subject to and shall be governed exclusively by the terms and conditions stated herein (the “Agreement”). The Buyer’s acceptance of any offer to sell is limited to the terms and conditions in the Agreement. Any terms or conditions in addition to or inconsistent with those stated in the Agreement, proposed by the Buyer in any acceptance of an offer by the Seller, are hereby rejected. No such additional, different or inconsistent terms and conditions shall become part of the agreement between the Buyer and the Seller unless expressly accepted in writing by the Seller. The Seller’s acceptance of any offer to purchase by the Buyer is expressly conditioned upon the Buyer’s assent to all the terms and conditions in this Agreement, irrespective of any terms in addition to, or inconsistent with those contained in the
Buyer’s offer. Acceptance of the Seller’s products shall in all events constitute such assent.
2. Documents.
Unless provided otherwise in the Agreement, all catalog descriptions, illustrations, drawings and literature or independently submitted estimates of performance, weights and measurements or other specifications provided by the Seller are mere approximations and the Seller reserves the right to alter or amend them at any time.
The Seller reserves the right to correct clerical or technical errors in the contract documents. The Buyer shall furnish with his order all necessary specifications and information. The Seller takes no responsibility for goods manufactured, priced or delivered not in accordance with the order or the specifications unless the Buyer’s order and specifications are clear and correct.
3. Prices.
Unless otherwise provided, all prices contained in our quotations and written acceptances are ex-works and do not include the cost of packing. All orders are accepted on the condition that all such prices are subject to revision by the Seller at any time before the goods are dispatched to take account of any price change. In the event that the Buyer does not place the entire order quoted by the Seller for the Buyer, the
Seller reserves the right to revise its prices. The Seller also reserves the right to revise its prices if the Buyer modifies the specification or quantity of the goods or the delivery requirements after the order has been accepted by the Seller.
4. Advice.
All advice given in connection with the Seller’s goods is provided without charge to the Buyer. ANY ADVICE AND ASSISTANCE GIVEN BY THE SELLER TO THE BUYER
IS GIVEN AT THE BUYER’S RISK, AND THE SELLER SHALL NOT BE LIABLE FOR
ANY LOSS, DAMAGE OR CLAIM ARISING THERE FROM Unless otherwise provided in the Agreement, or explicitly agreed upon in writing by the Seller, payment is due in accordance to the terms upon placement of order. If credit terms are in effect at time of purchase payment is due in full in 30 days. days from date of shipment of the items purchased herein under.
(a) Amounts not timely paid shall bear interest at the rate of 2-1/2% above the Seller’s bank’s prime rate from time to time in force.
(b) In the event that the Buyer fails within one calendar month of the date for payment to effect any payment which may be due under the Agreement or any agreement with the Seller, or if the Buyer commits any breach of the Agreement, or if the Buyer becomes insolvent or commits any act of bankruptcy or contemplation of liquidation, the Seller will be entitled, without prejudice to the Seller’s other rights, to terminate the Agreement or any unfulfilled part thereof, or at the Seller’s option to make partial deliveries.
5. Modifications and Cancellations.
This Agreement is not subject to oral modification or cancellation. A Buyer’s request for modification or cancellation will not be incorporated into the Agreement unless the request is accepted by the Seller in a writing that amends the Agreement. Acceptance of any such requested modification or cancellation shall be at the Seller’s discretion and shall be upon such terms and conditions as the Seller may require.
6. Handling Charge.
Goods supplied in accordance with the Buyer’s order may later be returned to the
Seller at the Seller’s discretion provided the return is pre-authorized in writing, and the merchandise is unused, in original packages, unaltered, clean and no older than 60 days from the date of shipment by the Seller. The Buyer will be required to pay to the
Seller a handling charge of 25% of the purchase price of the returned goods. A copy of the original invoice for the merchandise must accompany all returns.
7. Delivery.
(a) Any delivery dates quoted are approximate only and the Seller shall have no liability for any delays in delivery.
(b) Delivery of goods purchased from 3rd party marketplace are solely marketplace’s responsibility and Seller will not be responsible for any delay, missing or unshipped goods sent from 3rd party marketplace.
(c) Unless provided otherwise, delivery of the goods shall be made when the Seller has notified the Buyer that the goods are ready for dispatch. Regardless of the method of delivery, delivery shall be made F.O.B. Seller’s plant, where the risk of loss shall thereupon pass to the Buyer upon the Seller’s delivery to a carrier. Notwithstanding that the Seller’s prices are ex-works, the Seller is prepared by special contract to procure carriage or freight and insurance on behalf of the Buyer and at Buyer’s cost in which event the Seller shall be under no liability for damage in transit or loss or damage to the goods beyond the point at which the Seller contracts to deliver the same.
8. Inspection and Rejection.
(a) The following provisions shall apply in relation to all deliveries of goods: the Seller shall not be held liable for any claims of damage in transit, shortage of delivery or loss of goods, unless in the case of shortage of delivery, a separate notice in writing is given to the carrier concerned and to the Seller within three (3) days of the receipt of the goods, followed by a complete claim in writing within five (5) days of receipt of the goods and in the case of loss of goods, a separate notice in writing is given to the carrier concerned and to the Seller and a complete claim in writing made within thirty (30) days of the date of consignment. The Buyer must inspect the goods on arrival from the carrier; however, where goods are accepted from the carrier concerned without being inspected, the delivery book of the carrier concerned must be signed “not examined”.
The Seller shall have the right to inspect the goods at the Buyer’s premises in respect to any such claims made by the Buyer and the Buyer shall retain such goods until the
Seller has inspected such goods or until the Seller has notified the Buyer that the Seller does not wish to inspect such goods. Any breach of these conditions in this provision shall serve as a waiver to any claim brought by the buyer.
(b) Without prejudice to the Seller’s other rights, should the Buyer fail for any reason to send the Seller forwarding instructions within ninety (90) days after the date of the
Seller’s notification that the goods are ready for dispatch or to accept delivery of the goods, the Seller shall be entitled at the Buyer’s risk and expense to store the goods and/or to procure or effect storage of the goods elsewhere. Goods so stored shall be paid for as if they had been dispatched and/or accepted
9. Test and Performance.
(a) The Seller’s goods are, where practicable, submitted to the Seller’s standard test before delivery. If special tests are required, these shall be made at the Seller’s premises unless otherwise agreed, and will be subject to an extra charge.
(b) The Seller accepts no liability for failure to attain any performance figures quoted by the Seller unless the Seller specifically has guaranteed them with an agreed sum as liquidated damages and the Buyer has suffered actual loss by reason of the failure to attain the figures quoted.
(c) Any particulars of weights and measurements, power and consumption, power output or performance relating to the goods and like matters furnished by the Seller to the Buyer in the Seller’s catalogs, literature or otherwise, are approximate and are intended only to present a general idea of the goods to be supplied and unless previously agreed specifically in writing shall not form part of the Agreement.
10. Taxes.
Unless otherwise indicated, all prices and charges are exclusive of excise, sales, use, property, occupational or like taxes which may be imposed by any taxing authority upon the manufacture, sale or delivery of the items sold hereunder. If any such taxes must be paid by the Seller, or if the Seller is liable for the collection of such tax, the amount thereof shall be in addition to the amounts for the item sold. The Buyer agrees to pay all such taxes or to reimburse the Seller therefore upon receipt of its invoice. If the Buyer claims exemption from any sales, use or other tax imposed by any taxing authority, the
Buyer shall promptly indemnify and hold the Seller harmless from and against any such tax, as well as any interest or penalties thereon which may be assessed if the items are held to be taxable.
11. Warranty.
EXCEPT AS EXPRESSLY WARRANTED IN WRITING BY THE SELLER, THE GOODS
SOLD BY THE SELLER ARE PURCHASED BY THE BUYER “AS IS.” THE SELLER
DOES NOT WARRANT THAT THE GOODS ARE OF MERCHANTABLE QUALITY
OR THAT THEY CAN BE USED FOR ANY PARTICULAR PURPOSE. EXCEPT AS
EXPRESSLY WARRANTED IN WRITING BY THE SELLER, THE SELLER MAKES
NO REPRESENTATION OR WARRANTY OF ANY KIND WITH RESPECT TO THE
PRODUCTS.
(a) The Seller warrants that the items sold hereunder shall be free from defects in material or workmanship at the time of shipment by the Seller. The Seller warrants that if within 12 months of delivery of the goods to the Buyer the Buyer returns immediately to the Seller’s premises any of the said goods which the Buyer believes to be defective, carrier paid, properly packed and clearly marked with the Buyer’s full name and address and any other information such as serial numbers which may be necessary to enable the goods to be identified, together with a complete description of the alleged defect, they will be repaired or new goods will be supplied in exchange and the goods so repaired or such new goods will be delivered to the Buyer free of charge at the Seller’s premises; provided, however, that the foregoing warranty shall be applicable only if upon demand by the Seller, the Buyer proves to the Seller’s satisfaction: (i) that the defect was due solely to defective workmanship; (ii) that no alterations or repairs have been made to the goods except with the Seller’s written consent; (iii) that the defect was not caused by any act of the Buyer or its agents; and
(iv) that the defect was not caused by any matter beyond the reasonable control of the
Seller, including, without limitation, accident or normal wear and tear.
(b) THIS WARRANTY DOES NOT APPLY UNLESS THE SELLER’S PRODUCTS ARE: (I)
USED IN DOMESTIC PLUMBING APPLICATIONS; (II) INSTALLED BY A LICENSED
CONTRACTOR, PLUMBER OR QUALIFIED EQUIPMENT INSTALLATION
PROFESSIONAL; AND (III) INSTALLED AND OPERATED IN ACCORDANCE WITH
PUBLISHED AQUASURE DRINKING WATER SYSTEM SPECIFICATIONS.
(c) All costs and expenses, including freight charges, customs duties, and insurance incurred in returning the goods to the Seller’s premises in accordance with this provision shall be paid by the Buyer. The benefit of this warranty shall not be assignable by the Buyer.
(d) THIS WARRANTY DOES NOT EXTEND TO ANY GOODS NOT MANUFACTURED
BY THE SELLER EVEN THOUGH SUPPLIED BY THE SELLER NOR DOES IT
EXTEND TO ANY SECOND-HAND OR RECONDITIONED GOODS NOR DOES IT
EXTEND TO COMPONENTS MANUFACTURED BY THE SELLER BUT INSTALLED,
ATTACHED OR WELDED BY THE BUYER OR HIS CUSTOMER ON EQUIPMENT
NOT MANUFACTURED BY THE SELLER. GOODS NOT MANUFACTURED BY THE
SELLER CARRY ONLY THE WARRANTY (IF ANY) OF THEIR MAKERS AND THE
BUYER IS ENTITLED TO THE BENEFIT THEREOF ONLY SO FAR AS THE SELLER
HAS THE POWER TO TRANSFER IT.
(e) THIS WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY
PERTAINING TO ITEMS PROVIDED HEREUNDER; THE SELLER MAKES NO
OTHER WARRANTY, GUARANTEE, OR REPRESENTATION OF ANY KIND
WHATSOEVER. ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO
MERCHANTABILITY AND FITNESS FOR PURPOSE, WHETHER EXPRESSED OR
IMPLIED, OR ARISING BY OPERATION OF LAW, TRADE USAGE, OR COURSE OF
DEALING, ARE HEREBY DISCLAIMED.
(f) NOTWITHSTANDING THE FOREGOING, THERE ARE NO WARRANTIES
WHATSOEVER ON ITEMS BUILT OR ACQUIRED WHOLLY OR PARTIALLY TO THE
BUYER’S DESIGNS OR SPECIFICATIONS.
12. Limited Remedy.
THE SELLER’S LIABILITY ARISING FROM OR IN ANY WAY CONNECTED WITH
THE ITEMS SOLD OR THIS AGREEMENT SHALL BE LIMITED EXCLUSIVELY TO
REPAIR OR REPLACEMENT OF THE ITEMS SOLD. IN NO EVENT SHALL THE
SELLER BE LIABLE TO THE BUYER OR ANY THIRD PARTY FOR ANY INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY KIND OR NATURE
WHATSOEVER, INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING
FROM OR IN ANY WAY CONNECTED WITH THIS AGREEMENT OR ANY ITEMS
SOLD, WHETHER ALLEGED TO ARISE FROM BREACH OF CONTRACT, EXPRESS
OR IMPLIED WARRANTY, OR IN TORT, INCLUDING WITHOUT LIMITATION,
NEGLIGENCE, FAILURE TO WARN OR STRICT LIABILITY. IN NO EVENT
SHALL THE SELLER BE LIABLE TO THE BUYER OR ANY OTHER ENTITY FOR
MORE THAN THE INVOICE PRICE RECEIVED BY THE SELLER FOR ANY NON-
CONFORMING PRODUCTS. THE SELLER SHALL NOT BE LIABLE TO THE BUYER
OR ANY OTHER ENTITY FOR PERSONAL INJURY, PROPERTY DAMAGE, OR
ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, PUNITIVE,
EXEMPLARY, SPECIAL, OR OTHER DAMAGES OF ANY KIND, INCLUDING
WITHOUT LIMITATION THE COST OF PROCUREMENT OF SUBSTITUTE GOODS,
THE LOSS OF PROFITS, PRODUCTS, OR PRODUCTION, OR THE INTERRUPTION
OF BUSINESS, HOWEVER CAUSED. THE SELLER SHALL NOT BE LIABLE TO THE
BUYER OR ANY OTHER ENTITY ON ANY THEORY OF LIABILITY INCLUDING
WITHOUT LIMITATION BREACH OF CONTRACT OR EXPRESS OR IMPLIED
WARRANTY, TORT, NEGLIGENCE, FAILURE TO WARN, OR STRICT LIABILITY, AND
WHETHER OR NOT THE SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. THE ESSENTIAL PURPOSE OF THIS PROVISION IS TO LIMIT THE
LIABILITY OF THE SELLER ARISING OUT OF THE SALE OF PRODUCTS TO THE
BUYER WHETHER FOR BREACH OF CONTRACT, NEGLIGENCE, OR ANY OTHER
THEORY OF LIABILITY. THESE LIMITATIONS SHALL APPLY NOTWITHSTANDING
ANY FAILURE OF ESSENTIAL PURPOSE OF ANY LIMITED REMEDY AND
NOTWITHSTANDING THE PROVISIONS OF ANY OTHER AGREEMENT BETWEEN
THE SELLER AND THE BUYER.
13. Indemnity for Infringement of Intellectual Property Rights.
(a) The Buyer shall defend and indemnify the Seller against all actions, claims, demands, penalties and costs by third parties in tort, or for infringement, or alleged infringement, of patents, trademarks, copyrights, trade dress, trade secret or other rights of any third party resulting from the goods manufactured in accordance with the Buyer’s specifications or based on any information provided by the Buyer. The
Buyer will defend any action against the Seller for title, patent, trademark, copyright infringement, or other claimed by a third party at the Buyer’s sole cost and expense.
(b) The Seller shall have no liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets or similar rights except as provided in this provision. The Seller will defend and indemnify the Buyer against allegations of infringement of patents, trademarks, copyrights, trade dress and trade secrets
(“Intellectual Property Rights”). The Seller will defend at its expense and will pay the cost of any settlement or damages awarded in an action brought against the
Buyer based on an allegation that an item sold pursuant to this contract infringes the Intellectual Property Rights of a third party. The Seller’s obligation to defend and indemnify the Buyer is contingent on the Buyer notifying the Seller within 10 days after sole control over the defense of any allegations or actions, including all negotiations for settlement or compromise. If an item sold hereunder is subject to a claim that it infringes the Intellectual Property Rights of a third party, the Seller may, at its sole expense and option, procure for the Buyer the right to continue using said item, replace or modify said item so as to make it non-infringing, or offer to accept return of said item and return the purchase price less a reasonable allowance for depreciation.
Notwithstanding the foregoing, the Seller shall have no liability for claims of infringement based on information provided by Buyer, or directed to items delivered hereunder for which the designs are specified in combination or use in a system of any item sold hereunder. The foregoing in this provision shall constitute the Seller’s sole and exclusive liability and the Buyer’s sole and exclusive remedy for infringement of
Intellectual Property Rights.
14. Waiver.
The Seller’s rights shall not be affected or restricted by any indulgence or forbearance granted to the Buyer. No waiver by the Seller of any breach shall operate as a waiver of any later breach.
15. Force Majeure.
The Seller shall be excused from performing any of its obligations under this Agreement which are prevented or delayed by any occurrence not within the reasonable control of the Seller, including but not limited to, accidents, acts of God, destruction or damage to the goods or the Seller’s manufacturing plant, delays or failures in delivery of carriers or suppliers, shortages of materials, strikes or other labor matters, floods, earthquakes, fire, riots, explosions, or any regulations, rules, ordinances or orders of any governmental authority, federal, state or local, whether such cause exists at the date of the order or not.
16. Buyer’s Representation of Solvency.
The Buyer hereby represents that as of the signing of this Agreement it was not insolvent within the meaning of the Uniform Commercial Code or any Bankruptcy
Laws.
17. Assignment and Delegation.
The rights and obligations of the parties under this Agreement may not be assigned or delegated, except on the express written consent of the other party to the assignment or delegation.
18. Integration.
The rights and obligations of the parties and the terms and conditions set forth herein, together with any amendments, modifications and any different terms and conditions expressly accepted by the Seller in writing, shall constitute a complete and exclusive statement of the terms of this Agreement. This Agreement supersedes not only all prior agreements, but also oral agreements made contemporaneously with the execution of this Agreement. All such materials may not be used to supplement, explain, or contradict the terms of this Agreement
19. Severability.
If any of these conditions or any part thereof purports to exclude or restrict or limit any liability and such exclusion or restriction or limitation is prohibited or rendered void or unenforceable by any legislation to which it is subject, or is itself prohibited or rendered void or unenforceable by any legislation to which it is subject, then the exclusion, restriction or limitation on the condition or part thereof in question shall be so prohibited or rendered void or unenforceable and the validity or enforceability of any other part of these provisions shall not thereby be affected.
20. Governing Law/Limitation on Actions.
The terms, conditions, rights, and obligations under this Agreement shall be construed under the laws of the State of California, without regard to principles of conflicts of laws. No actions arising out of the sale of the items sold hereunder or this Agreement may be brought by the Buyer more than two (2) years after such cause of action accrues.
www.AquasureUSA.com | 818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]

Public link updated
The public link to your chat has been updated.
Advertisement