Sminn BOX L DC1D Instruction Manual
Sminn BOX L DC1D is a versatile and feature-rich universal motor controller designed for swing, rising, sliding, or overhead gates of one electromechanical 24VDC engine. It offers a wide range of capabilities to enhance the automation, safety, and convenience of your gate system.
Advertisement
Advertisement
#
BOX L DC1D
UNIVERSAL MOTOR CONTROLLER
For one motor doors at 24 VDC
INSTRUCTIONS MANUAL
innovative in electronics
12
11
10
14
13
COMPONENTS SITUATION
Fig.1
9 8
1. VDC power fuse
2. Box cover LED terminal
3. TRSH radio card slot
4. Con guration keyboard
5. TEST start button
6. Terminal strip
7. Battery fuse
1
2
5
7
8. DC motor terminal strip
9. Power input terminal strip
10. Power fuse
11. High voltage zone
12. Semaphore card slot
13. Earth fast-on terminal
14. Toroidal power transformer
6
3
4
INDEX
Description ............................................. 2
Limitations on the use of
motor controllers ................................. 2
Warnings ................................................. 2
Installation ............................................... 3
Important safety instructions
for installation ........................................ 3
Important safety instructions
for usage .................................................. 3
Wiring ...................................................... 4
Setup ........................................................ 6
Door types .............................................. 7
Operating modes ................................. 7
Normal functionality of securities .. 7
Electrical wiring diagram .................. 8
Photocell power wiring....................... 8
Accesories and peripherals .............. 9
Learning maneuver ............................. 10
Options .................................................... 11
Timings ..................................................... 12
Maintenance ............................................ 13
Force diagram ........................................ 13
Warranty .................................................. 14
Waste of electrical and electronic
devices ..........……...................................... 14
Features .................................................... 15
CE declaration of conformity ........... 15
Notes .......................................................... 16
Error messages ...................................... 16
Parts explosion ...................................... 17
Simbols
......................................DC Motor
...........................Encoder pulses
....................................Flash lamp
...................................Electrolock
.................................Safety edge
............Normaly close contact
............Normaly open contact
..............................................Earth
....................High voltage zone
1
12
11
10
14
13
COMPONENTS SITUATION
Fig.1
9 8
1. VDC power fuse
2. Box cover LED terminal
3. TRSH radio card slot
4. Con guration keyboard
5. TEST start button
6. Terminal strip
7. Battery fuse
1
2
5
7
8. DC motor terminal strip
9. Power input terminal strip
10. Power fuse
11. High voltage zone
12. Semaphore card slot
13. Earth fast-on terminal
14. Toroidal power transformer
6
3
4
INDEX
Description ............................................. 2
Limitations on the use of
motor controllers ................................. 2
Warnings ................................................. 2
Installation ............................................... 3
Important safety instructions
for installation ........................................ 3
Important safety instructions
for usage .................................................. 3
Wiring ...................................................... 4
Setup ........................................................ 6
Door types .............................................. 7
Operating modes ................................. 7
Normal functionality of securities .. 7
Electrical wiring diagram .................. 8
Photocell power wiring....................... 8
Accesories and peripherals .............. 9
Learning maneuver ............................. 10
Options .................................................... 11
Timings ..................................................... 12
Maintenance ............................................ 13
Force diagram ........................................ 13
Warranty .................................................. 14
Waste of electrical and electronic
devices ..........……...................................... 14
Features .................................................... 15
CE declaration of conformity ........... 15
Notes .......................................................... 16
Error messages ...................................... 16
Parts explosion ...................................... 17
Simbols
......................................DC Motor
...........................Encoder pulses
....................................Flash lamp
...................................Electrolock
.................................Safety edge
............Normaly close contact
............Normaly open contact
..............................................Earth
....................High voltage zone
1
FEATURES
The BXL-DC1D universal motor controller is designed to be part of a gate automation system for swing, rising, sliding, or overhead gates of one electromechanical 24VDC engine.
Among other features the motor controller provides:
- Control 1 motor of 24VDC - 120W max.
- Automatic activation of the motor relays and lights without spark.
- Independent connection terminals for motor and encoder.
- Independent regulation of the power applied to the motor both in startup, maneuver and stop.
- Quick maneuver learning to ease installation.
- Limit switches control.
- Independent terminals for light barrier and safety edge with safety test option conforming to regulations.
- Connection to electric lock, garage light (impulsive or latched) and beacon light.
- Two independent key inputs for complete and pedestrian maneuvers.
- Connection sockets for radio card and
SMINN semaphore card.
- Status LEDs for all the inputs and outputs.
- Peripheral power output with resettable fuse.
- Optocoupled inputs with high electrical insulation.
- Intuitive menu using a keyboard and
LCD that eases the con guration and maintenance of the panel.
- Ability to protect the con guration with a password.
- Storage of the number of maneuvers and security failures to ease the maintenance.
MOTOR CONTROLLER USAGE
RESTRICTIONS
Operation is not guaranteed when installed in di erent equipment than the speci ed.
The manufacturer reserves the right to change the speci cations of these systems as well as this manual without prior warning. The equipment must be manipulated only by specialized and/or skilled personnel.
WARNING
This product must be used in installations which has been conceived for, considering any other as improper use. The packaging must not be dumped in the environment.
Keep products, packaging, wrapping, documentation, etc., out of the reach of children.
Follow the current local, national or
European regulations. The information contained in this document may have some mistakes that will be corrected in future editions. The manufacturer reserves the right to modify the contents of this document or the product without any prior warning.
2
THE USAGE INSTRUCTIONS OF THIS DEVICE SHALL BE HANDED TO THE USER, WHO WILL
HAVE THEM IN THEIR POSSESSION. IF THEY ARE MISLAID, THE USER CAN ASK FOR A COPY
O R D O W N L O A D I T D I R E C T L Y F R O M T H E W E B S I T E W W W . S M I N N . C O M
INSTALLATION
The motor controller is xed to the wall with just 3 screws, all of them external. See g.3
Make three holes in the wall following the printed cutout template at the bottom of the cardboard box.
Check that the limit switches, and if installed, the light barrier and the safety edge, are all working. See g. 1
Make sure the safety edge is not activated when the door/shutter is fully closed.
Cut the cable glands located at the bottom of the case and pass through them the wiring tube inside the case.
See the IMPORTANT SAFETY
Press the TEST button ( g.1) to start an opening maneuver. If the motor doesn´t move its conection could be reversed.
Correct it and repeat this step.
INSTRUCTIONS FOR INSTALLATION.
Connect the power supply, motor and SMINN MOTOR CONTROLLERS ARE device cables to the terminals of the EQUIPPED WITH A LED TO LET KNOW IF terminal strip as indicated in the printed circuit board. See g 1.
After activating the power supply, the
ON led will switch on . See g.1
Set up the timings and con guration of the board.
T H E D E V I C E I S P O W E R E D .
IMPORTANT SAFETY INSTRUCTIONS
FOR USAGE
IMPORTANT SAFETY INSTRUCTIONS
Once the controller is installed, as a prevention measure, the user must:
FOR INSTALLATIONS
Before installing the panel you should:
- Check that the door/shutter is in good mechanical condition and well balanced.
- Remove from the surroundings anything that is not needed and turn o AC power (VAC).
- Install the motor controller at a minimum height of 1,5m, preferably next to the door.
- Use power and motor cables of enough gauge.
- Power the board through a circuit breaker or security switch that can be easily reached by the end user.
- Keep the controller out of reach of children.
- Observe that there are no objects or people in the way when the gate is moving.
- You must take precautions when handling the gate manually
(unblocked) because it can move without control, due to its own weight, the state of xing points, springs and counterweights.
If you detect a malfunction of the system, call IMMEDIATELY the technical service. You must not use the mechanism as it can cause damage.
The European regulations for doors
EN 12453 and EN 12445 specify the minimum protection and safety levels for doors installed in houses and community and public facilities.
Collision with any object must be prevented or the contact force must be limited (safety edge), and in the case of automatic cycle, a presence detector must be used too (i.e. light barrier).
With the LED associated to each one of these inputs.
3
FEATURES
The BXL-DC1D universal motor controller is designed to be part of a gate automation system for swing, rising, sliding, or overhead gates of one electromechanical 24VDC engine.
Among other features the motor controller provides:
- Control 1 motor of 24VDC - 120W max.
- Automatic activation of the motor relays and lights without spark.
- Independent connection terminals for motor and encoder.
- Independent regulation of the power applied to the motor both in startup, maneuver and stop.
- Quick maneuver learning to ease installation.
- Limit switches control.
- Independent terminals for light barrier and safety edge with safety test option conforming to regulations.
- Connection to electric lock, garage light (impulsive or latched) and beacon light.
- Two independent key inputs for complete and pedestrian maneuvers.
- Connection sockets for radio card and
SMINN semaphore card.
- Status LEDs for all the inputs and outputs.
- Peripheral power output with resettable fuse.
- Optocoupled inputs with high electrical insulation.
- Intuitive menu using a keyboard and
LCD that eases the con guration and maintenance of the panel.
- Ability to protect the con guration with a password.
- Storage of the number of maneuvers and security failures to ease the maintenance.
MOTOR CONTROLLER USAGE
RESTRICTIONS
Operation is not guaranteed when installed in di erent equipment than the speci ed.
The manufacturer reserves the right to change the speci cations of these systems as well as this manual without prior warning. The equipment must be manipulated only by specialized and/or skilled personnel.
WARNING
This product must be used in installations which has been conceived for, considering any other as improper use. The packaging must not be dumped in the environment.
Keep products, packaging, wrapping, documentation, etc., out of the reach of children.
Follow the current local, national or
European regulations. The information contained in this document may have some mistakes that will be corrected in future editions. The manufacturer reserves the right to modify the contents of this document or the product without any prior warning.
2
THE USAGE INSTRUCTIONS OF THIS DEVICE SHALL BE HANDED TO THE USER, WHO WILL
HAVE THEM IN THEIR POSSESSION. IF THEY ARE MISLAID, THE USER CAN ASK FOR A COPY
O R D O W N L O A D I T D I R E C T L Y F R O M T H E W E B S I T E W W W . S M I N N . C O M
INSTALLATION
The motor controller is xed to the wall with just 3 screws, all of them external. See g.3
Make three holes in the wall following the printed cutout template at the bottom of the cardboard box.
Check that the limit switches, and if installed, the light barrier and the safety edge, are all working. See g. 1
Make sure the safety edge is not activated when the door/shutter is fully closed.
Cut the cable glands located at the bottom of the case and pass through them the wiring tube inside the case.
See the IMPORTANT SAFETY
Press the TEST button ( g.1) to start an opening maneuver. If the motor doesn´t move its conection could be reversed.
Correct it and repeat this step.
INSTRUCTIONS FOR INSTALLATION.
Connect the power supply, motor and SMINN MOTOR CONTROLLERS ARE device cables to the terminals of the EQUIPPED WITH A LED TO LET KNOW IF terminal strip as indicated in the printed circuit board. See g 1.
After activating the power supply, the
ON led will switch on . See g.1
Set up the timings and con guration of the board.
T H E D E V I C E I S P O W E R E D .
IMPORTANT SAFETY INSTRUCTIONS
FOR USAGE
IMPORTANT SAFETY INSTRUCTIONS
Once the controller is installed, as a prevention measure, the user must:
FOR INSTALLATIONS
Before installing the panel you should:
- Check that the door/shutter is in good mechanical condition and well balanced.
- Remove from the surroundings anything that is not needed and turn o AC power (VAC).
- Install the motor controller at a minimum height of 1,5m, preferably next to the door.
- Use power and motor cables of enough gauge.
- Power the board through a circuit breaker or security switch that can be easily reached by the end user.
- Keep the controller out of reach of children.
- Observe that there are no objects or people in the way when the gate is moving.
- You must take precautions when handling the gate manually
(unblocked) because it can move without control, due to its own weight, the state of xing points, springs and counterweights.
If you detect a malfunction of the system, call IMMEDIATELY the technical service. You must not use the mechanism as it can cause damage.
The European regulations for doors
EN 12453 and EN 12445 specify the minimum protection and safety levels for doors installed in houses and community and public facilities.
Collision with any object must be prevented or the contact force must be limited (safety edge), and in the case of automatic cycle, a presence detector must be used too (i.e. light barrier).
With the LED associated to each one of these inputs.
3
CONNECTIONS
4
The motor controller is powered with
230VAC 50Hz through terminals 1 and 2 and the ground connection is made in the FAST-ON connector located at the top left of the motor controller, marked
EARTH.
Use the terminals 12-13 to connect a
12V/24VDC - 1A electric lock. The controller can be set to activate the lock when opening and has options like “Reversing stroke” and “Final stroke”.
If desired, connect a 230VAC – 40W lamp in the terminals 3-4 to act as a maneuver beacon.
It is also possible to activate the garage light or turn on a temporization device using the terminals 5-6.
Terminals 14 and 15 are used to connect an optional 24V battery (or 2
12V batteries in series) for emergency maneuver. This connection will charge the battery with up to 150mA.
The motor controller can handle an
24DC electromechanical with encoder.
The 7 and 8 terminals are used for motor connection.
Term. 9: Encoder 5V power
Term. 10: Encoder pulses
Term. 11: Encoder power ground
Note : If the motor has no encoder the terminals 9, 10 and 11 will be left disconected.
The board has a peripheral power output of 15VDC – 3,5VA in the terminals 16 and 17 protected with a resettable fuse designed to power devices like light barriers. Also, terminal 18 is used as an speci c negative for light barrier test.
According to regulations.
The board has speci c inputs for opening and closing limit switches.
The contacts are normally closed and have a shared common to ease installation.
Use the terminals 25-26 to connect a switch that starts a complete maneuver and the terminals 26-27 to connect another switch for pedestrian manuever or closing.
Optional L.S.
EMERGENCY
STOP
It is possible to install an emergency stop button breaking both limit switches at the same time.
See options menu.
The radio socket can be used to connect an SMINN radio card, allowing the controller to be used with radio transmitters.
The controller can manage light barriers and a safety edge. The safety edge input can be set to manage a second light barrier or any kind of safety edge (resistive or contact).
Light barriers must always be normally closed. See options.
The semaphore card socket allows the board to manage, via an SMINN semaphore card, a two light semaphore and optionally use the red light as a maneuver beacon.
5
CONNECTIONS
4
The motor controller is powered with
230VAC 50Hz through terminals 1 and 2 and the ground connection is made in the FAST-ON connector located at the top left of the motor controller, marked
EARTH.
Use the terminals 12-13 to connect a
12V/24VDC - 1A electric lock. The controller can be set to activate the lock when opening and has options like “Reversing stroke” and “Final stroke”.
If desired, connect a 230VAC – 40W lamp in the terminals 3-4 to act as a maneuver beacon.
It is also possible to activate the garage light or turn on a temporization device using the terminals 5-6.
Terminals 14 and 15 are used to connect an optional 24V battery (or 2
12V batteries in series) for emergency maneuver. This connection will charge the battery with up to 150mA.
The motor controller can handle an
24DC electromechanical with encoder.
The 7 and 8 terminals are used for motor connection.
Term. 9: Encoder 5V power
Term. 10: Encoder pulses
Term. 11: Encoder power ground
Note : If the motor has no encoder the terminals 9, 10 and 11 will be left disconected.
The board has a peripheral power output of 15VDC – 3,5VA in the terminals 16 and 17 protected with a resettable fuse designed to power devices like light barriers. Also, terminal 18 is used as an speci c negative for light barrier test.
According to regulations.
The board has speci c inputs for opening and closing limit switches.
The contacts are normally closed and have a shared common to ease installation.
Use the terminals 25-26 to connect a switch that starts a complete maneuver and the terminals 26-27 to connect another switch for pedestrian manuever or closing.
Optional L.S.
EMERGENCY
STOP
It is possible to install an emergency stop button breaking both limit switches at the same time.
See options menu.
The radio socket can be used to connect an SMINN radio card, allowing the controller to be used with radio transmitters.
The controller can manage light barriers and a safety edge. The safety edge input can be set to manage a second light barrier or any kind of safety edge (resistive or contact).
Light barriers must always be normally closed. See options.
The semaphore card socket allows the board to manage, via an SMINN semaphore card, a two light semaphore and optionally use the red light as a maneuver beacon.
5
6
CONFIGURATION
The controller has an advanced menu system using an integrated keyboard and backlit LCD display to make con guration and maintenance easy, fast and intuitive.
Press the BACK and ENTER keys simultaneously to access the con guration menu. The LCD backlight will power on.
There are 4 keys to move through the menu:
BACK (exit)
ENTER (accept)
<- (back)
-> (forward)
The <- / -> keys, are used to move through the selected menu options or settings.
The ENTER key is used to accept and validate the selection.
The controller has a con guration wizard that allows the installer to set up the most important con guration parameters and get the board working faster.
To use the wizard, go into the main menu pressing BACK + ENTER, press
→
until “MANEUVER PROG” is shown in the screen and accept pressing
ENTER.
After this, the controller will ask one by one the most important con guration parameters to the installer. Please choose the appropiate settings using
←
and
→
and press ENTER to continue or BACK to go back.
Once the needed con guration is done, the controller will prompt the installer to press ENTER to start the learning maneuver.
From here on the ENTER key, the LL1 input or a radio transmitter can be used for the learning process.
BACK
SMINN
BOXL DC1D
ENTER
BACK ENTER
CONFIGURATION MENUS
OPTIONS
Automatic closing
Fast beam closing
Optional Automatic
Invert on Key
Partial times
Limit switches
Light Barrier / Light Barrier Test
Light Barrier Mode
Band type
Band mode
Pressure Mode
Hardware short-circuit
Electrolock Type
Soft stop enabled
Close on boot
Flashing semaphore
Auxiliary dead-man
Encoder / Time Encoder
Limit switch Stop
Switch 1 / Switch 2 lock
ADJUSTMENTS
Opening time / Pedestrian
Closing time / Pedestrian
Extra time
Automatic closing / pedestrian
Close on beam
Direc. change time / inversion
Electrolock / reverse stroke
Power
Soft stop
Final stroke time
Pre ashing / Garage light
Pressure sensibility
Pressure limit
Overcurrent limit
MAINTENANCE
Version
Partial / Total counter
Input status
Open / Close
Default values
Enable / Change password
PROGRAMMING WIZARD
DOOR TYPES
The controller can be set up for four
.
di erent kind of gates.
.
- SWING
- RISING (Vertical)
.
- OVERHEAD
.
.
- SLIDING
.
OPERATING MODES
In all the modes securities worked as shown in the attached chart except when indicated otherwise.
The STOP input stops instantaneously
.
the maneuver.
STANDARD
In this mode LL1 and radio starts a full maneuver and LL2 starts a pedestrian maneuver. It is not possible to
.
interrupt the opening in this mode.
OPEN/CLOSE
In this mode LL1 opens and LL2 closes. Any of these signals interrupt
.
the current maneuver immediately.
ALTERNATING STOP
In this mode LL1 and radio starts a full maneuver and LL2 starts a pedestrian maneuver. It is possible to interrupt the maneuver using any of these inputs; when the gate is moving any input will make it stop, when it is stopped any input will make in go the
.
other way.
DEAD MAN
This mode only allows the gate to move while the LL1 input or radio are active (open) or the LL2 input is active (close). The maneuver interrupts immediately when there is no active input.
In this mode securities only pause the
.
maneuver.
SEMIAUTOMATIC DEAD MAN
The gate opens fully when the LL1 input or radio are active but only allows closing while the LL2 input is kept active. Securities function normally while opening and only pause while closing.
NORMAL FUNCTIONALITY OF
SECURITIES
CLOSING LIGHT BARRIER
Closing: Inverts the maneuver
Opening: Nothing
CLOSING SAFETY EDGE
Closing: Inverts 3 seconds and stops
Opening: Stops immediately
OPENING LIGHT BARRIER
Closing: Inverts the maneuver
Opening: Pauses the maneuver
OPENING SAFETY EDGE
Closing: Stops the maneuver.
Opening: Inverts 3 seconds and stops
After STOP or a safety edge collision the next maneuver inverts direction.
7
6
CONFIGURATION
The controller has an advanced menu system using an integrated keyboard and backlit LCD display to make con guration and maintenance easy, fast and intuitive.
Press the BACK and ENTER keys simultaneously to access the con guration menu. The LCD backlight will power on.
There are 4 keys to move through the menu:
BACK (exit)
ENTER (accept)
<- (back)
-> (forward)
The <- / -> keys, are used to move through the selected menu options or settings.
The ENTER key is used to accept and validate the selection.
The controller has a con guration wizard that allows the installer to set up the most important con guration parameters and get the board working faster.
To use the wizard, go into the main menu pressing BACK + ENTER, press
→
until “MANEUVER PROG” is shown in the screen and accept pressing
ENTER.
After this, the controller will ask one by one the most important con guration parameters to the installer. Please choose the appropiate settings using
←
and
→
and press ENTER to continue or BACK to go back.
Once the needed con guration is done, the controller will prompt the installer to press ENTER to start the learning maneuver.
From here on the ENTER key, the LL1 input or a radio transmitter can be used for the learning process.
BACK
SMINN
BOXL DC1D
ENTER
BACK ENTER
CONFIGURATION MENUS
OPTIONS
Automatic closing
Fast beam closing
Optional Automatic
Invert on Key
Partial times
Limit switches
Light Barrier / Light Barrier Test
Light Barrier Mode
Band type
Band mode
Pressure Mode
Hardware short-circuit
Electrolock Type
Soft stop enabled
Close on boot
Flashing semaphore
Auxiliary dead-man
Encoder / Time Encoder
Limit switch Stop
Switch 1 / Switch 2 lock
ADJUSTMENTS
Opening time / Pedestrian
Closing time / Pedestrian
Extra time
Automatic closing / pedestrian
Close on beam
Direc. change time / inversion
Electrolock / reverse stroke
Power
Soft stop
Final stroke time
Pre ashing / Garage light
Pressure sensibility
Pressure limit
Overcurrent limit
MAINTENANCE
Version
Partial / Total counter
Input status
Open / Close
Default values
Enable / Change password
PROGRAMMING WIZARD
DOOR TYPES
The controller can be set up for four
.
di erent kind of gates.
.
- SWING
- RISING (Vertical)
.
- OVERHEAD
.
.
- SLIDING
.
OPERATING MODES
In all the modes securities worked as shown in the attached chart except when indicated otherwise.
The STOP input stops instantaneously
.
the maneuver.
STANDARD
In this mode LL1 and radio starts a full maneuver and LL2 starts a pedestrian maneuver. It is not possible to
.
interrupt the opening in this mode.
OPEN/CLOSE
In this mode LL1 opens and LL2 closes. Any of these signals interrupt
.
the current maneuver immediately.
ALTERNATING STOP
In this mode LL1 and radio starts a full maneuver and LL2 starts a pedestrian maneuver. It is possible to interrupt the maneuver using any of these inputs; when the gate is moving any input will make it stop, when it is stopped any input will make in go the
.
other way.
DEAD MAN
This mode only allows the gate to move while the LL1 input or radio are active (open) or the LL2 input is active (close). The maneuver interrupts immediately when there is no active input.
In this mode securities only pause the
.
maneuver.
SEMIAUTOMATIC DEAD MAN
The gate opens fully when the LL1 input or radio are active but only allows closing while the LL2 input is kept active. Securities function normally while opening and only pause while closing.
NORMAL FUNCTIONALITY OF
SECURITIES
CLOSING LIGHT BARRIER
Closing: Inverts the maneuver
Opening: Nothing
CLOSING SAFETY EDGE
Closing: Inverts 3 seconds and stops
Opening: Stops immediately
OPENING LIGHT BARRIER
Closing: Inverts the maneuver
Opening: Pauses the maneuver
OPENING SAFETY EDGE
Closing: Stops the maneuver.
Opening: Inverts 3 seconds and stops
After STOP or a safety edge collision the next maneuver inverts direction.
7
8
pagina central
ELECTRICAL
CONNECTIONS
3
4
1 230VAC phase
2 230VAC Neutral
Beacon light 230V 40W
5
6
POTENTIAL FREE relay contacts for garage light or auxiliary lamp.
7
8
Motor Connection 24VDC
9 + Encoder power
10 Encoder signal
11 - Encoder power
12
Electrolock 12/24 VDC
13
14 + Battery
24VDC
15 - Battery
16 Positive VDC power for light barriers and other
17 Negative peripherals
18 Negative power output for light barrier with autotest
19 NC opening limit switch
20 Limit switch common
21 NC closing limit switch
22 NC light barrier contact
23 Securities common
24 R8K2/NC contact for safety edge
25 Start complete maneuver input
26 Start/Stop common
27 Pedestrian start / dead-man input
Fig.2
LIGHT BARRIER POWER CONNECTIONS
+
-
RX TX
+
-
Radio card
ACCESORIES
AND PERIPHERALS
Semaphore card
Transmitter-receiver light barrier set
Light barrier transmitter negative must be connected to terminal 18 to use light barrier test
Beacon light and light barrier stand
9
8
pagina central
ELECTRICAL
CONNECTIONS
3
4
1 230VAC phase
2 230VAC Neutral
Beacon light 230V 40W
5
6
POTENTIAL FREE relay contacts for garage light or auxiliary lamp.
7
8
Motor Connection 24VDC
9 + Encoder power
10 Encoder signal
11 - Encoder power
12
Electrolock 12/24 VDC
13
14 + Battery
24VDC
15 - Battery
16 Positive VDC power for light barriers and other
17 Negative peripherals
18 Negative power output for light barrier with autotest
19 NC opening limit switch
20 Limit switch common
21 NC closing limit switch
22 NC light barrier contact
23 Securities common
24 R8K2/NC contact for safety edge
25 Start complete maneuver input
26 Start/Stop common
27 Pedestrian start / dead-man input
Fig.2
LIGHT BARRIER POWER CONNECTIONS
+
-
RX TX
+
-
Radio card
ACCESORIES
AND PERIPHERALS
Semaphore card
Transmitter-receiver light barrier set
Light barrier transmitter negative must be connected to terminal 18 to use light barrier test
Beacon light and light barrier stand
9
10
LEARNING MANEUVER
The learning maneuver is useful to set the temporization parameters of the controller. It is di erent depending on whether slow stop has been activated or not.
LEARNING WITHOUT SOFT STOP
Close door
LEARNING WITH SOFT STOP
Close gate.
Press ENTER to learn opening
Press ENTER to learn opening Press ENTER for soft stop
Press ENTER to stop the gate or wait for opening limit switch (FCA)
STOP
Press ENTER to learn closing
Press ENTER to stop the gate or wait for opening limit switch (FCA)
STOP
Press ENTER to learn closing
Press ENTER for soft close
Press ENTER to stop the gate or wait for closing limit switch (FCC)
Gate closed
Press ENTER to stop the gate or wait for closing limit switch (FCC)
Gate closed
OPTIONS
LCD TEXT
AUTOMATIC CLOSING
Enables automatic closing after pause time
FAST BEAM CLOSING
If the manuever inverts because of a light barrier the pause time is reduced to the one set in Close on Beam
OPTIONAL AUTOMATIC
Allows to end the pause time prematurely
AUTO DELAY ON KEY
Reinicia el tiempo de pausa con cada orden de maniobra
Only visible with Opt. Auto Clossing o
INVERT ON KEY
Allows ton invert the maneuver in STANDARD mode
PARTIAL TIMES
Invert as much times as the gate has closed plus extra time
LIMIT SWITCH
Enables the inputs for limit switch
LIGHT BARRIER
Enables management of light barrier
LIGHT BARRIER TEST 1 - LIGHT BARRIER TEST 2
Enables autotest for light barrier before maneuver
LIGHT BARRIER MODE 1 - LIGHT BARRIER MODE 2
Con gures behavior of each lighbarrier when opening / closing
Opts.: NOTHING / PAUSE / INVERT / STOP / SHORT INVERT
EDGE
Enables the input for a closing safety edge.
Its supports 8K2, NA or NC safety edge or NC light barrier.
Options: NO / R8K2 / NA / NC / BEAM
SAFETY EDGE MODE / IMPACT MODE
Con gures behaviour of security when Opening / Closing
Options: NOTHING / STOP / SHORT INVERT / INVERT
SHORTCIRCUIT HARDWARE SENSOR
Enables the fast detection of short circuit
ELECTROLOCK TYPE
Voltage to apply on the electrolock. 12V or 24V
SOFT STOP
Soft Stop enabled
CLOSE ON BOOT
When the controller is powered on it initiates a closing maneuver if the closing limit switch is not active.
FLASHING SEMAPHORE
Use the red light as maneuver beacon
AUXILIARY DEAD MAN
If the light barrier test fails the controller sets itself in dead-man mode temporarily so the gate can be opened securely.
ENCODER
Maneuver control via encoder
TIME ENCODER
Simulates an encoder counting pulses considering time and power. Maneuver invert timings are more precise but it requires similar speed when opening and closing
STOP IN LIMIT SWITCHES
Enables the emergency stop breaking the limit switches
SWITCH 1 LOCK - SWITCH 2 LOCK
Locks the switch 1 / 2
Only visible when password is enabled
AUTO CLOSE
FAST BEAM CLOSE
OPTIONAL AUTO
AUTO DEL KEY
INVER ON KEY
PARTIAL TIMES
FCA1
FCC1
BEAM
TEST BEAM 1
TEST BEAM 2
BEAM 1 OPEN
BEAM 1 CLOSE
BEAM 2 OPEN
BEAM 2 CLOSE
EDGE
EDGE OPEN
EDGE CLOSE
PUSH OPEN
PUSH CLOSE
HW SC TRIP
ELOCK TYPE
SOFT STOP
CLOSE ON BOOT
FLASHING SEM.
AUX DEAD MAN
ENCODER
TIME ENCODER
STOP LIM SW
LL1 LOCK
LL2 LOCK
DEFAULT
VALUE
YES
NO
YES
NO
YES
NO
YES
YES
NO
NO
NO
NO
NOTHING
INVERT
PAUSE
INVERT
NO
NO
STOP
SHORT INV.
SHORT INV.
SHORT INV.
YES
12V
YES
NO
NO
YES
NO
NO
YES
NO
NO
11
10
LEARNING MANEUVER
The learning maneuver is useful to set the temporization parameters of the controller. It is di erent depending on whether slow stop has been activated or not.
LEARNING WITHOUT SOFT STOP
Close door
LEARNING WITH SOFT STOP
Close gate.
Press ENTER to learn opening
Press ENTER to learn opening Press ENTER for soft stop
Press ENTER to stop the gate or wait for opening limit switch (FCA)
STOP
Press ENTER to learn closing
Press ENTER to stop the gate or wait for opening limit switch (FCA)
STOP
Press ENTER to learn closing
Press ENTER for soft close
Press ENTER to stop the gate or wait for closing limit switch (FCC)
Gate closed
Press ENTER to stop the gate or wait for closing limit switch (FCC)
Gate closed
OPTIONS
LCD TEXT
AUTOMATIC CLOSING
Enables automatic closing after pause time
FAST BEAM CLOSING
If the manuever inverts because of a light barrier the pause time is reduced to the one set in Close on Beam
OPTIONAL AUTOMATIC
Allows to end the pause time prematurely
AUTO DELAY ON KEY
Reinicia el tiempo de pausa con cada orden de maniobra
Only visible with Opt. Auto Clossing o
INVERT ON KEY
Allows ton invert the maneuver in STANDARD mode
PARTIAL TIMES
Invert as much times as the gate has closed plus extra time
LIMIT SWITCH
Enables the inputs for limit switch
LIGHT BARRIER
Enables management of light barrier
LIGHT BARRIER TEST 1 - LIGHT BARRIER TEST 2
Enables autotest for light barrier before maneuver
LIGHT BARRIER MODE 1 - LIGHT BARRIER MODE 2
Con gures behavior of each lighbarrier when opening / closing
Opts.: NOTHING / PAUSE / INVERT / STOP / SHORT INVERT
EDGE
Enables the input for a closing safety edge.
Its supports 8K2, NA or NC safety edge or NC light barrier.
Options: NO / R8K2 / NA / NC / BEAM
SAFETY EDGE MODE / IMPACT MODE
Con gures behaviour of security when Opening / Closing
Options: NOTHING / STOP / SHORT INVERT / INVERT
SHORTCIRCUIT HARDWARE SENSOR
Enables the fast detection of short circuit
ELECTROLOCK TYPE
Voltage to apply on the electrolock. 12V or 24V
SOFT STOP
Soft Stop enabled
CLOSE ON BOOT
When the controller is powered on it initiates a closing maneuver if the closing limit switch is not active.
FLASHING SEMAPHORE
Use the red light as maneuver beacon
AUXILIARY DEAD MAN
If the light barrier test fails the controller sets itself in dead-man mode temporarily so the gate can be opened securely.
ENCODER
Maneuver control via encoder
TIME ENCODER
Simulates an encoder counting pulses considering time and power. Maneuver invert timings are more precise but it requires similar speed when opening and closing
STOP IN LIMIT SWITCHES
Enables the emergency stop breaking the limit switches
SWITCH 1 LOCK - SWITCH 2 LOCK
Locks the switch 1 / 2
Only visible when password is enabled
AUTO CLOSE
FAST BEAM CLOSE
OPTIONAL AUTO
AUTO DEL KEY
INVER ON KEY
PARTIAL TIMES
FCA1
FCC1
BEAM
TEST BEAM 1
TEST BEAM 2
BEAM 1 OPEN
BEAM 1 CLOSE
BEAM 2 OPEN
BEAM 2 CLOSE
EDGE
EDGE OPEN
EDGE CLOSE
PUSH OPEN
PUSH CLOSE
HW SC TRIP
ELOCK TYPE
SOFT STOP
CLOSE ON BOOT
FLASHING SEM.
AUX DEAD MAN
ENCODER
TIME ENCODER
STOP LIM SW
LL1 LOCK
LL2 LOCK
DEFAULT
VALUE
YES
NO
YES
NO
YES
NO
YES
YES
NO
NO
NO
NO
NOTHING
INVERT
PAUSE
INVERT
NO
NO
STOP
SHORT INV.
SHORT INV.
SHORT INV.
YES
12V
YES
NO
NO
YES
NO
NO
YES
NO
NO
11
12
ADJUSTMENTS
Leaf open time
Pedestrian leaf open time
Leaf close time
Pedestrian close
Extra time
Automatic close time
Pedestrian automatic close time
Lightbarrier close time
Short inversion time
Electrolock time
Reversing stroke time
Power
Soft stop power
Final stroke
Pre ashing time
Garage light time
Push current sensitivity
Push current limit
Overcurrent limit
LCD TEXT
LEAF 1 OPEN
PEDESTR. OPEN
LEAF 1 CLOSE
PEDESTR. CLOSE
EXTRA TIME
AUTO CLOSE
PED. AUTO CL.
CLOSE ON BEAM
SHORT INV. T.
ELECTROLOCK
0 sec.
2 sec.
0 sec
REVERS. STROKE
POWER
SOFT POWER
FINAL STROKE
PREFLASHING
GARAGE LIGHT
M1 SENSIB.
M1 PUSH. LIM.
M1 OC. LIM.
0 sec.
75%
40%
0 sec.
2 sec.
120 sec.
3
3A
5A
DEFAULT
VALUE
15 sec.
5 sec.
15 sec.
5 sec.
0 sec.
60 sec.
20 sec.
ADJUSTMENTS
1-240 sec.
0-120 sec.
1-240 sec.
0-120 sec.
No/1-50 sec.
1-360 sec.
1-240 sec.
2-240 sec.
1-240 sec.
2-10 sec
0-5 sec.
30-90%
30-90%
0-3 sec.
0-10 sec.
0-240 sec.
0-9
0-20A
0-25A
Note: The motor controller has a precision current sensor that monitors the motor current displaying in real time the instant current and the overcurrent limit.
3 di erent securities may be set for the maneuver:
- Pressure sensitivity : The controller analyses the difference in motor current between normal movement and an obstacle, acting like a con gurable security that can be set in the adjustments menu.
- Impact current limit : A motor current limit can be set helping to guarantee motor life against steep impacts or gate mechanical problems.
- Overcurrent limit : This security cuts current to the motor when a shortcircuit or overcurrent happens, helping to protect the power supply and the controller electronics.
MAINTENANCE
This menu can be used to check the maneuver counters, input status, password con guration and doing factory reset.
PARTIAL COUNTER
I t shows the total number of maneuvers since the last reset.
Pressing ENTER on this option you can reset the partial meter, starting at 0.
TOTAL COUNTER
Displays the number of maneuvers performed since installation.
This counter can not be set to 0.
INPUT STATUS
Displays the status of all con gured inputs.
The safety edge will not appear unless it is enabled
DEFAULT VALUES
Reset to the default setting
(Factory Reset)
ENABLE PASSWORD
Enables a 4 digit password to access the menu.
The default password is: 1234
CHANGE PASSWORD
Changes the controller 4 digit password.
OPEN
Forces opening while Enter is held.
Use to test the motor direction.
CLOSE
Forces closing while Enter is held.
Use to test the motor direction.
Temporally and depending on use the installation must be thoroughly tested by quali ed personnel to detect any sign of wear.
If the board needs repair please contact the manufacturer or the nearest o cial service.
Once the controller is set up the installer must ensure the power and slow stop adjustments meet the EN12453:2000 regulations by performing the meterings described in the EN12445:2000 regulations. See force graph.
If these requirements are not met additional securities must be installed.
The dynamic force (Fd) must not surpass the following measures:
< 400N in spaces between 5-50cm
< 1400N in spaces greater than 50cm
Force graph
Fd: Dynamic force
Fs: Static force
S M I N N o e r s t h e i n s t a l l e r a pro esional grade technical support service that will solve any problem and extend if needed the device warranty.
13
12
ADJUSTMENTS
Leaf open time
Pedestrian leaf open time
Leaf close time
Pedestrian close
Extra time
Automatic close time
Pedestrian automatic close time
Lightbarrier close time
Short inversion time
Electrolock time
Reversing stroke time
Power
Soft stop power
Final stroke
Pre ashing time
Garage light time
Push current sensitivity
Push current limit
Overcurrent limit
LCD TEXT
LEAF 1 OPEN
PEDESTR. OPEN
LEAF 1 CLOSE
PEDESTR. CLOSE
EXTRA TIME
AUTO CLOSE
PED. AUTO CL.
CLOSE ON BEAM
SHORT INV. T.
ELECTROLOCK
0 sec.
2 sec.
0 sec
REVERS. STROKE
POWER
SOFT POWER
FINAL STROKE
PREFLASHING
GARAGE LIGHT
M1 SENSIB.
M1 PUSH. LIM.
M1 OC. LIM.
0 sec.
75%
40%
0 sec.
2 sec.
120 sec.
3
3A
5A
DEFAULT
VALUE
15 sec.
5 sec.
15 sec.
5 sec.
0 sec.
60 sec.
20 sec.
ADJUSTMENTS
1-240 sec.
0-120 sec.
1-240 sec.
0-120 sec.
No/1-50 sec.
1-360 sec.
1-240 sec.
2-240 sec.
1-240 sec.
2-10 sec
0-5 sec.
30-90%
30-90%
0-3 sec.
0-10 sec.
0-240 sec.
0-9
0-20A
0-25A
Note: The motor controller has a precision current sensor that monitors the motor current displaying in real time the instant current and the overcurrent limit.
3 di erent securities may be set for the maneuver:
- Pressure sensitivity : The controller analyses the difference in motor current between normal movement and an obstacle, acting like a con gurable security that can be set in the adjustments menu.
- Impact current limit : A motor current limit can be set helping to guarantee motor life against steep impacts or gate mechanical problems.
- Overcurrent limit : This security cuts current to the motor when a shortcircuit or overcurrent happens, helping to protect the power supply and the controller electronics.
MAINTENANCE
This menu can be used to check the maneuver counters, input status, password con guration and doing factory reset.
PARTIAL COUNTER
I t shows the total number of maneuvers since the last reset.
Pressing ENTER on this option you can reset the partial meter, starting at 0.
TOTAL COUNTER
Displays the number of maneuvers performed since installation.
This counter can not be set to 0.
INPUT STATUS
Displays the status of all con gured inputs.
The safety edge will not appear unless it is enabled
DEFAULT VALUES
Reset to the default setting
(Factory Reset)
ENABLE PASSWORD
Enables a 4 digit password to access the menu.
The default password is: 1234
CHANGE PASSWORD
Changes the controller 4 digit password.
OPEN
Forces opening while Enter is held.
Use to test the motor direction.
CLOSE
Forces closing while Enter is held.
Use to test the motor direction.
Temporally and depending on use the installation must be thoroughly tested by quali ed personnel to detect any sign of wear.
If the board needs repair please contact the manufacturer or the nearest o cial service.
Once the controller is set up the installer must ensure the power and slow stop adjustments meet the EN12453:2000 regulations by performing the meterings described in the EN12445:2000 regulations. See force graph.
If these requirements are not met additional securities must be installed.
The dynamic force (Fd) must not surpass the following measures:
< 400N in spaces between 5-50cm
< 1400N in spaces greater than 50cm
Force graph
Fd: Dynamic force
Fs: Static force
S M I N N o e r s t h e i n s t a l l e r a pro esional grade technical support service that will solve any problem and extend if needed the device warranty.
13
14
WARRANTY
This product has undergone a complete
TEST during its manufacturing process that guarantees its reliability and proper operation. The manufacturer provides 24 months of warranty to the product from the date printed in the product and against any anomaly that it may present in its appearance or operation.
Any damage caused by third parties, natural causes ( ooding, re, lightning, etc), arising from improper handling or installation, vandalism or any other cause non attributable to the manufacturer will void the warranty.
The warranty only covers repairs or replacement of the damaged device.
Any expenses derived from assembling, travelling, transport, natural wear of parts, etc., and, in general, any expenses that are not part of the repairs or replacement of the damaged element of the system are excluded.
The installer/provider will ask the manufacturer for a RMA number or authorization for transport of the system in warranty. Without this previous requisite, the manufacturer will not be able neither to process nor provide warranty service.
WASTE OF ELECTRICAL AND
ELECTRONIC DEVICES (WEEE)
In accordance with the European
Directive 2002/96/EC about waste electrical and electronic equipment
(WEEE), the presence of this symbol
(see symbol at the bottom of this text) in the product or in the packaging, means that this article shall not be disposed in local nonclassi ed waste streams.
It is the user's responsibility to dispose this product taking it to a collection point designed for waste recycling of electrical and electronic devices. The separate collection of this product helps optimize the waste sorting and recycling of any recyclable material and also decreases the impact on health and the environment. For more information about the correct wasting of this product, please contact the local authority or the distributor where you acquired this product.
TECHNICAL
CHARACTERISTICS
Power supply
Maximun charge
AC main fues
DC main fuse
Battery fuse
Power output
Power output protection
Electrolock output
Battery
Maneuver control inputs
Plug-in cards
LCD display
Operation temp.
Casing
Dimensions
Weight
Watertight
CE DECLARATION OF CONFORMITY
The company ELSON ELECTRÓNICA, S. A.
Pol. Torrelarragoiti, P6 – A3
48170 Zamudio – Vizcaya (SPAIN)
Declares:
The product
Manufactures
Under the trademark
BOX L DC1D motor controller
SMINN
For use in Residential, Commercial or light industry enviroments.
This device meets the provisions as long as its usage is compilant to what was envisaged, having applied the following regulations:
Electromagnetic compatibility:
Low tension:
Machines:
EN 61000-3-2/3
EN 61000-6/1-2-3-4
EN 60335-1
EN 60335-2-95/103
EN 12453:2000
EN 12445:2000
Zamudio a 12.04.2012
230VAC
24V / 120W
2A
6/8A delayed
6A delayed
15VDC / 3.5VA (300mA)
Rearmable fuse
12/24VDC / 1A selectable
24V (2x12V in series)
6 high insulation optoacoupled inputs
1 analog inputs
Radio and semaphore
2x16 characters Chip-on-glass technology - Backlight
-20ºC / 70ºC
ABS
L280 x W196 x H90 mm
2200g
IP54 (IP65 with cable glands)
José Miguel Blanco Pérez
Chief Technical O cer innovative in electronics www. sminn.com
15
14
WARRANTY
This product has undergone a complete
TEST during its manufacturing process that guarantees its reliability and proper operation. The manufacturer provides 24 months of warranty to the product from the date printed in the product and against any anomaly that it may present in its appearance or operation.
Any damage caused by third parties, natural causes ( ooding, re, lightning, etc), arising from improper handling or installation, vandalism or any other cause non attributable to the manufacturer will void the warranty.
The warranty only covers repairs or replacement of the damaged device.
Any expenses derived from assembling, travelling, transport, natural wear of parts, etc., and, in general, any expenses that are not part of the repairs or replacement of the damaged element of the system are excluded.
The installer/provider will ask the manufacturer for a RMA number or authorization for transport of the system in warranty. Without this previous requisite, the manufacturer will not be able neither to process nor provide warranty service.
WASTE OF ELECTRICAL AND
ELECTRONIC DEVICES (WEEE)
In accordance with the European
Directive 2002/96/EC about waste electrical and electronic equipment
(WEEE), the presence of this symbol
(see symbol at the bottom of this text) in the product or in the packaging, means that this article shall not be disposed in local nonclassi ed waste streams.
It is the user's responsibility to dispose this product taking it to a collection point designed for waste recycling of electrical and electronic devices. The separate collection of this product helps optimize the waste sorting and recycling of any recyclable material and also decreases the impact on health and the environment. For more information about the correct wasting of this product, please contact the local authority or the distributor where you acquired this product.
TECHNICAL
CHARACTERISTICS
Power supply
Maximun charge
AC main fues
DC main fuse
Battery fuse
Power output
Power output protection
Electrolock output
Battery
Maneuver control inputs
Plug-in cards
LCD display
Operation temp.
Casing
Dimensions
Weight
Watertight
CE DECLARATION OF CONFORMITY
The company ELSON ELECTRÓNICA, S. A.
Pol. Torrelarragoiti, P6 – A3
48170 Zamudio – Vizcaya (SPAIN)
Declares:
The product
Manufactures
Under the trademark
BOX L DC1D motor controller
SMINN
For use in Residential, Commercial or light industry enviroments.
This device meets the provisions as long as its usage is compilant to what was envisaged, having applied the following regulations:
Electromagnetic compatibility:
Low tension:
Machines:
EN 61000-3-2/3
EN 61000-6/1-2-3-4
EN 60335-1
EN 60335-2-95/103
EN 12453:2000
EN 12445:2000
Zamudio a 12.04.2012
230VAC
24V / 120W
2A
6/8A delayed
6A delayed
15VDC / 3.5VA (300mA)
Rearmable fuse
12/24VDC / 1A selectable
24V (2x12V in series)
6 high insulation optoacoupled inputs
1 analog inputs
Radio and semaphore
2x16 characters Chip-on-glass technology - Backlight
-20ºC / 70ºC
ABS
L280 x W196 x H90 mm
2200g
IP54 (IP65 with cable glands)
José Miguel Blanco Pérez
Chief Technical O cer innovative in electronics www. sminn.com
15
NOTES DC1D EXPLOSION
1 2
3
4
Fig3
5
16
ERROR MESSAGE
When an error happens during maneuver, the controller stores the error along with other previous errors so that next time the con guration menu is accessed they can be displayed. When there are errors to be displayed an “E” appears in the four corners of the screen. When the con guration menu is accessed the controller displays one by one the stored errors.
The possible errors are:
SEG 1 / 2 TEST FAIL
The test procedure of the indicated security has failed. For SEG 1/2 it is the standard test procedure for light barriers.
BND 1 TEST FAIL
The test procedure of the indicated security has failed.
The safety edge may be blocked or have an electrical problem.
SECURITY FAIL SEG BLOCKED
At least one security was blocked before starting the maneuver.
MOTOR OC
The motor stopped because of overconsumption. This security activates when surpassing the current limit set in the menu.
MOTOR SC
The motor stopped because of a shortcircuit.
MOTOR PUSH
The obstacle detection security was activated while operating the motor.
10
9
8
6
11
7
1. Captive screws
2. Power status LED
3. Semaphore card
4. Vacuum rubber gasket
5. External xing with just three screws
6. Access ports for 16/24mm tubes
7. Radio card
8. Plug-in terminal blocks
9. Power relays
10. Display
11. Frontal space for installer/revision
sticker
17
NOTES DC1D EXPLOSION
1 2
3
4
Fig3
5
16
ERROR MESSAGE
When an error happens during maneuver, the controller stores the error along with other previous errors so that next time the con guration menu is accessed they can be displayed. When there are errors to be displayed an “E” appears in the four corners of the screen. When the con guration menu is accessed the controller displays one by one the stored errors.
The possible errors are:
SEG 1 / 2 TEST FAIL
The test procedure of the indicated security has failed. For SEG 1/2 it is the standard test procedure for light barriers.
BND 1 TEST FAIL
The test procedure of the indicated security has failed.
The safety edge may be blocked or have an electrical problem.
SECURITY FAIL SEG BLOCKED
At least one security was blocked before starting the maneuver.
MOTOR OC
The motor stopped because of overconsumption. This security activates when surpassing the current limit set in the menu.
MOTOR SC
The motor stopped because of a shortcircuit.
MOTOR PUSH
The obstacle detection security was activated while operating the motor.
10
9
8
6
11
7
1. Captive screws
2. Power status LED
3. Semaphore card
4. Vacuum rubber gasket
5. External xing with just three screws
6. Access ports for 16/24mm tubes
7. Radio card
8. Plug-in terminal blocks
9. Power relays
10. Display
11. Frontal space for installer/revision
sticker
17
innovative in electronics

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Control 1 motor of 24VDC - 120W max.
- Independent connection terminals for motor and encoder.
- Independent regulation of the power applied to the motor both in startup, maneuver and stop.
- Quick maneuver learning to ease installation.
- Independent terminals for light barrier and safety edge with safety test option conforming to regulations.