www.netafim.com

The smart valve with

3 Independent

programs + 2

extra modes

o opcional en f

READ & KEEP

2

AQUA PRO Irrigation Controller

Easy to use battery operated irrigation controller.

Two in one: an irrigation controller and AQUANET, a state of the art electric valve combined.

Offers 3 independent programs + 2 extra modes.

Programs:

P1 : Once a day at the same time every day.

(Factory preset 15 minutes at 06:00 A.M).

P2 : Once a day at the same time on selected Active days.

P3 : Up to three start times per day on selected days.

Extra Modes

OFF : stops all irrigation activities.

Manual : to start/stop a program manually.

Start: press both <SET> and keys.

Stop: press both <SET> and keys.

Automatic stop: when the duration time of the active program (P) passes.

Waterproof: I.P. 67.

Contains a backup battery to safeguard your settings.

Available in sizes: 3/4” and 1”.

Stick your language sticker on the inside cover.

Programm

Press and hold

Press the

Increase

P1

- Sets the entry and proceed.

briefly: Once for P1.

Decrease

P2

2

. 4 times -

Four times for

Manual Operation:

To start: press &

To stop: press &

OFF button

Seconds

blinking digit.

P3

P3. -

Once daily at same time.

Up to 3 irrigations per day:

<SET> battery duration.

start time.

Table of contents:

Installation

Controller Keyboard

Controller Icons & Display

Electric valve control button

Battery Insertion or replacement

Installation into the watering system

Programming steps

Set P1

Set p2

Set P3

Programming guide table

Controller display in operating mode

Technical information

Warranty

Programm

Press and hold

Press the

Increase

- Sets the entry and proceed.

briefly: Once for P1.

Decrease

. 4 times -

2

Seconds

P2. -

P3. -

P1. -

Four times for

Manual Operation:

To start: press &

Once daily on selected days.

Up to 3 irrigations per day:

OFF

<SET>

<SET> button

blinking digit.

Low battery

P3 start time.

4

9

10

7

8

11

12

14

5

6

15

3

E

E

Installation

Controller Keyboard

<MODE> : To select operating sequence and to enter programming.

<SET> : To set program values and advance to next step.

: Increase program values.

: Decrease program values.

4

Controller Icons & Display

Days - represented by the digits 1-7.

Chosen day is framed.

Current day is blinking.

Hours - represented in 24 hours format.

P1, P2 or P3 - operating modes.

Set current

time and day.

Irrigation duration.

start time.

.e.g. 1, 3, 5, 7, Active Days.

P3 -3 start times per day.

Manual irrigation.

Low battery.

Electric valve control buttons

Auto:

Close:

Open:

Note: If the override button

(marked with a red arrow) is in Close position the AQUA

PRO will remain closed.

If the override button

(marked with a red arrow) is in Open position the AQUA

PRO will remain open.

Flow Control:

Flow Direction:

(see page 7)

5

E

Battery Insertion or replacement

E

Note: to operate your controller you need a high quality

9V alkaline battery (not included)

The Low battery sign appears - insert or replace the battery

To insert or to replace the battery:

1. Release the four screws of the

battery compartment cover.

2. Gently remove the cover, seal

and screws. Take care to keep

the screws and seal in a safe place.

3. Insert/replace a new battery.

4. Replace the seal cover

and screws

5. Tighten the screws.

6

Installation into the watering system

1. Turn off the main water supply

2. Install the AQUA PRO into the

watering system making sure

that the water flow is in the

direction of the arrow on the

base of the valve.

3. Turn on the main water supply

4. You can control the flow using

the Flow Control lever on the

base marked from <+> to <->.

When installing the AQUA PRO, hold the valve only.

E

7

E

Programming steps

Note: Make sure that the override button (marked

with a red arrow) is in the central position AUTO).

Set Clock current time and day

Press <MODE> for 2 seconds.

1. Use or keys to adjust (MINS.)

2. Press <SET> to continue.

3. Use or keys to adjust (HRS.)

4. Press <SET> to continue.

5. Use or keys to select day of the week.

6. Press <SET>.

Clock setting is completed.

Important!

If no key is pressed for more than 30 seconds during

programming,the controller resumes operating mode.

8

Set P1

Once a day at the same time every day.

Press <MODE> twice for 2 seconds.

Set Irrigation duration

7. Use or keys to adjust (MINS.)

8. Press <SET> to continue.

9. Use or keys to adjust (HRS.)

10. Press <SET> to continue.

Set irrigation starting time

11. Use or keys to adjust (MINS.)

12. Press <SET> to continue.

13. Use or keys to adjust (HRS.)

14. Press <SET> to continue.

P1 programming is completed.

E

9

E

Set P2

Once a day at the same time on selected Active days

Note: Irrigation duration and start time has already

been set at P1.To change irrigation duration and/or

start time, go back to P1 (7-14)

Press <MODE> three times for 2 seconds.

15. Press to activate day 1.

16. Press to deactivate day 1.

17. Press <SET> to continue to day 2

18. Press to activate day 2.

19. Press to deactivate day 2.

20. Set in a similar way days 3,4,5,6,7.

P2 programming is completed. day 1 ÒblinksÓ

10

Set P3

Up to three start times per day on selected Active days.

Press <MODE> four times for 2 seconds.

21. To Set duration for

(follow the instruction of P1. 7-14)

22. Set in a similar way for

and

23. To Select active days

(follow the instruction of P2. 15-20)

P3 programming is completed.

Note: To select an active program: press the <MODE> button

briefly: once for P1, twice for P2 three times for P3. and

four times to turn the controller OFF.

E

11

E

Programming guide table (example)

Example Day Active day Duration Start time

P1 0:15 08:00

6

7

4

5

1

2

3 x x x x x x x

Example

P2

Day

1

4

5

2

3

6

7

Active day x x x x

Duration

0:15

Start time

08:00

12

Example

P3

Day

6

7

4

5

1

2

3

Active day x x x x

Duration

0:15

0:15

0:15

Start time

1

2

3

Hour

08:00

13:00

18:00

Your program guide table

P1 Day Active day Duration Start time

6

7

4

5

1

2

3 x x x x x x x

P2

Day

1

4

5

2

3

6

7

Active day Duration Start time

P3 Day

6

7

4

5

1

2

3

Active day Duration Start time Hour

13

E

E

Controller display in operating mode

Real time clock

Current day (blinking)

Active mode (P1, P2, P3 or OFF).

Technical information

Flow Range: 25-6000L/H (0.1 to 26 GPM).

Minimum pressure: 0.2 BAR (3 PSI.).

Maximum pressure: 10 BAR (150 PSI).

Valve cable 0.6 M. connected to the Controller. Maximum extension from the valve to the Controller 100 M (330- feet)

(cable 1.0mm Ø).

AQUA PRO controller is compatible also with

Aquanet 1.5”, 2”. (D.C).

Operating Temperature: 0

°

to 50

°

C (32

°

-122

°

F).

Storage Temperature: -10

°

to 60

°

C (14

°

-140

°

F).

14

Warranty

Basic Netafim Warranty.

Netafim products are guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of delivery.

Netafim reserves the right to alter, modify or redesign its products, pricing and warranty at all times without creating any liability for the obsolescence of customer inventory of such parts or products.

This warranty does not apply where equipment is not used and installed strictly in accordance with Netafim specifications and

User Manual. Neither does it apply to failures caused by lightning strikes or damage due to freezing temperatures or mechanical causes (e.g. lawnmowers) Netafim is not liable for indirect, incidental or consequential damage in connection with the use of equipment.

This manufacturer warranty policy may apply differently in different countries.

For more information, contact your Netafim distributor

Email: [email protected]

E

To receive warranty benefits, customers should return defective parts to the nearest Netafim distributor.

15