Dell EMC OpenManage Enterprise Power Manager software User's guide

Add to My manuals
84 Pages

advertisement

Dell EMC OpenManage Enterprise Power Manager software User's guide | Manualzz

Dell EMC OpenManage Enterprise Power

Manager Version 2.0

User’s Guide

June 2021

Rev. A00

Notes, cautions, and warnings

NOTE: A NOTE indicates important information that helps you make better use of your product.

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

© 2019 - 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.

Other trademarks may be trademarks of their respective owners.

Contents

Chapter 1: Introduction to Power Manager.................................................................................... 6

Chapter 2: What is new in this release........................................................................................... 7

Chapter 3: Compatibility matrix.................................................................................................... 8

Supported devices in Power Manager........................................................................................................................... 8

Supported PDU device manufacturers................................................................................................................... 10

Hardware requirements.............................................................................................................................................. 10

Supported protocols..........................................................................................................................................................10

Versions of Power Manager compatible with OpenManage Enterprise...............................................................10

Role and scope-based access control in OpenManage Enterprise ....................................................................... 11

Chapter 4: License requirements................................................................................................. 15

Chapter 5: Scalability and performance....................................................................................... 17

Chapter 6: Getting started with Power Manager.......................................................................... 18

Install Power Manager...................................................................................................................................................... 18

Set preferences..................................................................................................................................................................19

Add devices to Power Manager..................................................................................................................................... 21

Add static groups to Power Manager.......................................................................................................................... 22

Chapter 7: Create a device discovery job..................................................................................... 23

Schedule job field definitions..........................................................................................................................................24

Create customized device discovery job protocol for SNMP devices................................................................. 24

Chapter 8: Monitor and manage Power Manager devices............................................................. 25

View metrics, and monitor devices and groups history........................................................................................... 26

Virtual machines................................................................................................................................................................ 28

View virtual machines.................................................................................................................................................28

Thresholds...........................................................................................................................................................................29

Create alert thresholds.............................................................................................................................................. 29

Policies..................................................................................................................................................................................31

Static policy................................................................................................................................................................... 31

Temperature-triggered policy................................................................................................................................... 31

Create static or temperature-triggered policy..................................................................................................... 32

Chapter 9: Rack management......................................................................................................36

Add unmonitored device details.....................................................................................................................................36

Add or edit device details for Power Manager monitored devices....................................................................... 37

Create physical groups.....................................................................................................................................................38

Creating physical groups in OpenManage Enterprise.........................................................................................38

Add devices in physical group.................................................................................................................................. 39

Contents 3

Create physical groups through CSV file.............................................................................................................. 40

Power Distribution Unit.................................................................................................................................................... 41

Associate PDU to rack ...............................................................................................................................................41

Chapter 10: Manage data center during power reduction............................................................. 43

Enable Emergency Power Reduction........................................................................................................................... 43

View active Emergency Power Reduction.................................................................................................................. 44

Disable Emergency Power Reduction.......................................................................................................................... 45

Chapter 11: Quick access to Power Manager data........................................................................ 46

View power and thermal history of Power Manager groups.................................................................................. 46

View top five energy consumers................................................................................................................................... 46

View ratio of devices discovered in OpenManage Enterprise to devices added in Power Manager............ 47

View top ten power offenders....................................................................................................................................... 47

View top ten temperature offenders............................................................................................................................48

View top ten underutilized racks for power and space............................................................................................48

View power and space headroom................................................................................................................................. 49

Chapter 12: Maintain Power Manager ......................................................................................... 50

Manage Power Manager plugin..................................................................................................................................... 50

Disable Power Manager ............................................................................................................................................50

Enable Power Manager ..............................................................................................................................................51

Manage individual devices and static groups..............................................................................................................51

View devices and groups added to Power Manager........................................................................................... 51

Remove devices...........................................................................................................................................................52

Remove groups............................................................................................................................................................ 53

Manage physical groups.................................................................................................................................................. 53

View physical groups and the hierarchies............................................................................................................. 53

View devices added in rack.......................................................................................................................................54

View racks of physical groups..................................................................................................................................55

Edit physical groups....................................................................................................................................................55

Delete physical group................................................................................................................................................. 56

Rearrange rack slot of devices................................................................................................................................ 56

Move device to different rack..................................................................................................................................57

Remove device from rack......................................................................................................................................... 58

Maintain alert thresholds.................................................................................................................................................58

View alert thresholds..................................................................................................................................................58

Edit alert thresholds................................................................................................................................................... 59

Delete alert thresholds...............................................................................................................................................60

Maintain policies................................................................................................................................................................. 61

View policy.....................................................................................................................................................................61

Edit policy......................................................................................................................................................................62

Disable policy................................................................................................................................................................ 63

Enable policy................................................................................................................................................................. 63

Delete policy................................................................................................................................................................. 64

Managing unmonitored devices..................................................................................................................................... 64

View details of Unmonitored Devices.....................................................................................................................64

Edit Unmonitored Devices details............................................................................................................................64

Delete Unmonitored Devices.................................................................................................................................... 65

4 Contents

Manage PDU devices ......................................................................................................................................................65

View PDUs associated to rack in Power Manager.............................................................................................. 65

Remove PDU devices.................................................................................................................................................66

Uninstalling Power Manager ..........................................................................................................................................67

Chapter 13: Alerts....................................................................................................................... 68

Create alert policy ............................................................................................................................................................68

Chapter 14: Reports in Power Manager........................................................................................69

Create custom report.......................................................................................................................................................69

View and download reports............................................................................................................................................ 70

Chapter 15: Update Power Manager.............................................................................................72

Configure OpenManage Enterprise for Power Manager updates......................................................................... 72

Upgrade Power Manager.................................................................................................................................................73

Chapter 16: Frequently Asked Questions......................................................................................74

Chapter 17: Troubleshooting........................................................................................................80

Chapter 18: Appendix.................................................................................................................. 83

Chapter 19: Other information you may need............................................................................... 84

Contents 5

1

Introduction to Power Manager

Dell EMC OpenManage Enterprise Power Manager is a plugin to the Dell EMC OpenManage Enterprise (OME) console and uses fine-grained instrumentation to provide increased visibility to power consumption, system anomalies, and resource utilization on

Dell EMC servers. Also, Power Manager supports virtual machine monitoring, and alerts and reports about power and thermal events in servers, chassis, and custom groups consisting of servers and chassis. This reporting enables increased control, faster response times, greater accuracy, and broader decision-making intelligence than is otherwise possible.

When used with PowerEdge servers, modular systems with an iDRAC Enterprise or iDRAC Datacenter license, or supported chassis and OpenManage Enterprise Advanced license, Power Manager leverages information from the OME console to deliver platform-level power reporting. Power Manager then communicates with Integrated Dell Remote Access Controller (iDRAC) or

Chassis Management Controller (CMC) on each managed device to provide power-management data and execution of control policy—making it easy for administrators to identify areas in which they can gain efficiencies and cut wasteful costs. Also,

Power Manager supports monitoring and managing power load on Power Distribution Units (PDUs) by communicating with the

PDU firmware.

6 Introduction to Power Manager

2

What is new in this release

● Support for monitoring Power Distribution Unit (PDU) devices.

● Support for monitoring Virtual Machines (VM) that are hosted on hypervisors that have been discovered in OpenManage

Enterprise and added to Power Manager.

● Power Manager: Virtual Machine Performance Report integrated to view VM details monitored in Power Manager.

● Support for monitoring 8000 devices that include servers, PDUs, virtual machines, and 500 groups (static and physical).

● Support for Scope-Based Access Control (SBAC) feature enhancing security.

● Support for communicating with servers to collect data through Redfish telemetry protocol.

● Support for creating physical groups by importing a CSV file.

What is new in this release 7

3

Compatibility matrix

Topics:

Supported devices in Power Manager

Supported protocols

Versions of Power Manager compatible with OpenManage Enterprise

Role and scope-based access control in OpenManage Enterprise

Supported devices in Power Manager

Power Manager supports the following list of Dell EMC PowerEdge servers and chassis.

Table 1. Supported servers and chassis models

Category

Server

Model

● Dell EMC VxRail E460

● Dell EMC VxRail E460F

● Dell EMC VxRail E560

● Dell EMC VxRail E560F

● Dell EMC VxRail E560N

● Dell EMC VxRail P470

● Dell EMC VxRail P470F

● Dell EMC VxRail P570

● Dell EMC VxRail P570F

● Dell EMC VxRail P580N

● Dell EMC VxRail S470

● Dell EMC VxRail S570

● Dell EMC VxRail V470

● Dell EMC VxRail V470F

● Dell EMC VxRail V570

● Dell EMC VxRail V570F

● Dell EMC PowerEdge R320

● Dell EMC PowerEdge R330

● Dell EMC PowerEdge R340

● Dell EMC PowerEdge R420

● Dell EMC PowerEdge R430

● Dell EMC PowerEdge R440

● Dell EMC PowerEdge R520

● Dell EMC PowerEdge R530

● Dell EMC PowerEdge R530XD

● Dell EMC PowerEdge R540

● Dell EMC PowerEdge R620

● Dell EMC PowerEdge R630

● Dell EMC PowerEdge R640

● Dell EMC PowerEdge R6415

● Dell EMC PowerEdge R650

● Dell EMC PowerEdge R6515

● Dell EMC PowerEdge R6525

● Dell EMC PowerEdge R720

8 Compatibility matrix

Table 1. Supported servers and chassis models (continued)

Category Model

● Dell EMC PowerEdge R720xd

● Dell EMC PowerEdge R730

● Dell EMC PowerEdge R730Xd

● Dell EMC PowerEdge R740

● Dell EMC PowerEdge R740XD

● Dell EMC PowerEdge R740xd2

● Dell EMC PowerEdge R7415

● Dell EMC PowerEdge R7425

● Dell EMC PowerEdge R750

● Dell EMC PowerEdge R750 XA

● Dell EMC PowerEdge R7515

● Dell EMC PowerEdge R7525

● Dell EMC PowerEdge R820

● Dell EMC PowerEdge R830

● Dell EMC PowerEdge R840

● Dell EMC PowerEdge R920

● Dell EMC PowerEdge R930

● Dell EMC PowerEdge R940

● Dell EMC PowerEdge R940xa

● Dell EMC PowerEdge M620

● Dell EMC PowerEdge M520

● Dell EMC PowerEdge M630

● Dell EMC PowerEdge M640

● Dell EMC PowerEdge M830

● Dell EMC PowerEdge T320

● Dell EMC PowerEdge T330

● Dell EMC PowerEdge T340

● Dell EMC PowerEdge T420

● Dell EMC PowerEdge T620

● Dell EMC PowerEdge T430

● Dell EMC PowerEdge T440

● Dell EMC PowerEdge T630

● Dell EMC PowerEdge FC430

● Dell EMC PowerEdge FC630

● Dell EMC PowerEdge FC640

● Dell EMC PowerEdge FC830

● Dell EMC PowerEdge C6320

● Dell EMC PowerEdge C6320p

● Dell EMC PowerEdge C6420

● Dell EMC PowerEdge C6525

● Dell EMC PowerEdge MX740C

● Dell EMC PowerEdge MX840C

● Dell EMC PowerEdge XE2420

● Dell EMC PowerEdge XE7420

● Dell EMC PowerEdge XE7440

● Dell EMC PowerEdge XE8545

Chassis ● Dell EMC PowerEdge M1000e

● Dell EMC PowerEdge VRTX Blade Enclosure

● Dell EMC PowerEdge FX2/FX2s

● Dell EMC PowerEdge MX7000

Compatibility matrix 9

Supported PDU device manufacturers

The following are the Power Distribution Unit (PDU) device brands that are supported in Power Manager:

● Vertiv Geist

● APC by Schneider Electric

Hardware requirements

The following table lists the minimum set of hardware configurations that are based on the number of devices you want to monitor through Power Manager.

Table 2. Minimum required hardware

Minimum recommended hardware

Large deployments

Number of devices that Power

Manager can manage.

Up to 8000

RAM

Processors

Hard drive

32 GB

8 cores

250 GB

Small deployments

1000

16 GB

4 cores

250 GB

Supported web browsers

Power Manager supports the following versions of web browsers:

● Internet Explorer (64-bit) 11 and later

● Mozilla Firefox 52 and later

● Google Chrome 58 and later

● Microsoft Edge version 41.16299 and later

Power Manager does not support the following:

● PowerEdge M1000e, PowerEdge VRTX, PowerEdge FX2, and PowerEdge FX2s chassis discovered with viewer credentials

● Servers with cabled Power Supply Units (PSUs)

● PowerEdge FM120x4

● Hypervisors with viewer credentials

● iDRAC firmware version 4.00.00.00

Supported protocols

Power Manager supports the following protocols:

● Power Manager modifies the following with respect to Telemetry Streaming service in iDRAC to retrieve metrics through

Redfish protocol:

○ Enables Telemetry Data Stream

○ Adds or uploads a OME-PMP-Power-A custom Metric Report Definition report.

● Simple Network Management Protocol (SNMP) for Power Distribution Unit (PDU) devices.

● Web Services for Management (WSMAN) protocol for servers and chassis.

● Representational State Transfer (REST) protocol for PowerEdge MX7000 chassis.

Versions of Power Manager compatible with

OpenManage Enterprise

The following table shows Power Manager and OpenManage Enterprise version compatibility.

10 Compatibility matrix

Table 3. Compatibility matrix of Power Manager and OpenManage Enterprise

Power Manager Version

Power Manager 2.0

OpenManage Enterprise Version

OpenManage Enterprise 3.6

Power Manager 1.1 and 1.2

Power Manager 1.0

● OpenManage Enterprise 3.4

● OpenManage Enterprise 3.4.1

● OpenManage Enterprise 3.5

● OpenManage Enterprise 3.2

● OpenManage Enterprise 3.2.1

● OpenManage Enterprise 3.3

● OpenManage Enterprise 3.3.1

Role and scope-based access control in OpenManage

Enterprise

OpenManage Enterprise has Role Based Access Control (RBAC) that clearly defines the user privileges for the three built-in roles—Administrator, Device Manager, and Viewer. Additionally, using the Scope-Based Access Control (SBAC) an administrator can limit the device groups that a device manager has access to. The following topics further explain the RBAC and SBAC features.

Role-Based Access Control (RBAC) privileges in OpenManage Enterprise

Users are assigned roles which determine their level of access to the appliance settings and device management features. This feature is termed as Role-Based Access Control (RBAC). The console enforces the privilege required for a certain action before allowing the action.

This table lists the various privileges that are enabled for each role.

Table 4. Role-based user privileges for Power Manager

Features Administrator

Install Power Manager Yes

Upgrade Power

Manager

Yes

Enable Power

Manager

Yes

Device Manager

(scope for assigned groups)

No

No

No

Yes No Disable Power

Manager

Uninstall Power

Manager

Modify Power

Manager Settings.

View Power Manager

Settings

Add supported devices from Power

Manager

Remove supported devices from Power

Manager

Yes

Yes

Yes

Yes

Yes

No

No

Yes

No

Yes

Device Manager (scope for non-assigned groups)

No

No

No

No

No

No

Yes

No

No

Viewer

No

No

No

No

No

No

Yes

No

No

Compatibility matrix 11

Table 4. Role-based user privileges for Power Manager (continued)

Features Administrator

Yes

Device Manager

(scope for assigned groups)

Yes

Device Manager (scope for non-assigned groups)

No Add or remove static groups from Power

Manager

Add or remove unsupported devices from Power Manager.

Add or remove Power

Distribution Units

(PDUs) from Power

Manager.

Yes

Yes

No

No

No

No

Yes

No

No

No

Monitor PDUs.

Create, edit, or delete

Physical Groups.

Import physical groups through CSV file

Yes

Yes

Yes

Manage the devices in rack.

Monitor metrics.

Yes

Yes

Manage power policies for devices.

Yes

Manage power policies for groups.

Yes

Manage temperaturetriggered policies for groups.

Yes

Manage alert thresholds for devices.

Yes

Yes Manage alert thresholds for groups.

View alert thresholds in Power Manager

Manage Emergency

Power Reduction

(EPR) for devices.

Manage EPR for groups.

Run and view reports for devices and groups.

Manage custom reports for devices.

Manage custom reports for groups.

View events

Dashboard

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

Viewer

No

No

No

Yes

No

No

No

Yes

No

No

No

No

No

Yes

No

No

Yes

No

No

Yes

Yes

12 Compatibility matrix

Scope-Based Access Control (SBAC) in OpenManage Enterprise

With the use of Role-Based Access Control (RBAC) feature, administrators can assign roles while creating users. Roles determine their level of access to the appliance settings and device management features. Scope-based Access Control (SBAC) is an extension of the RBAC feature that allows an administrator to restrict a Device Manager role to a subset of device groups called scope.

While creating or updating a Device Manager (DM) user, administrators can assign scope to restrict operational access of DM to one or more system groups, custom groups, and / or plugin groups.

Administrator and Viewer roles have unrestricted scope. That means they have operational access as specified by RBAC privileges to all devices and groups entities.

Scope can be implemented as follows:

1. Create or Edit User

2. Assign DM role

3. Assign scope to restrict operational access

When a Device Manager (DM) user with an assigned scope logs in, the DM can see and manage scoped devices only. Also, the

DM can see and manage entities such as jobs, firmware or configuration templates and baselines, alert policies, profiles, and so on associated with scoped devices, only if the DM owns the entity (DM has created that entity or is assigned ownership of that entity). For more information about the entities a DM can create, see Role-Based Access Control (RBAC) privileges in

OpenManage Enterprise .

In OpenManage Enterprise, scope can be assigned while creating a local or importing AD/LDAP user. Scope assignment for

OIDC users can be done only on Open ID Connect (OIDC) providers.

SBAC for Local users:

While creating or editing a local user with DM role, admin can select one or more device groups that defines the scope for the

DM.

For example, you (as an administrator) create a DM user named dm1 and assign group g1 present under custom groups. Then dm1 will have operational access to all devices in g1 only. The user dm1 cannot access any other groups or entities related to any other devices.

Furthermore, with SBAC, dm1 will also not be able to see the entities created by other DMs (let us say dm2) on the same group g1 . That means a DM user will only be able to see the entities owned by the user.

For example, you (as an administrator) create another DM user named dm2 and assign the same group g1 present under custom groups. If dm2 creates configuration template, configuration baselines, or profiles for the devices in g1 , then dm1 will not have access to those entities and vice versa.

A DM with scope to All Devices has operational access as specified by RBAC privileges to all devices and group entities that are owned by the DM.

SBAC for AD/LDAP users:

While importing or editing AD/LDAP groups, administrators can assign scopes to user groups with DM role. If a user is a member of multiple AD groups, each with a DM role, and each AD group has distinct scope assignments, then the scope of the user is the union of the scopes of those AD groups.

For example,

● User dm1 is a member of two AD groups ( RR5-Floor1-LabAdmins and RR5-Floor3-LabAdmins ). Both AD groups have been assigned the DM role, with scope assignments for the AD groups are as follows: RR5-Floor1-LabAdmins gets ptlab-servers and RR5-Floor3-LabAdmins gets smdlab-servers . Now the scope of the DM dm1 is the union of ptlab-servers and smdlabservers .

● User dm1 is a member of two AD groups ( adg1 and adg2 ). Both AD groups have been assigned the DM role, with scope assignments for the AD groups as follows: adg1 is given access to g1 and adg2 is given access to g2 . If g1 is the superset of g2 , then the scope of dm1 is the larger scope ( g1 , all its child groups, and all leaf devices).

When a user is a member of multiple AD groups that have different roles, the higher-functionality role takes precedence (in the order Administrator, DM, Viewer).

A DM with unrestricted scope has operational access as specified by RBAC privileges to all device and group entities.

SBAC for OIDC users:

Scope assignment for OIDC users does not happen within the OME console. You can assign scopes for OIDC users at an OIDC provider during user configuration. When the user logs in with OIDC provider credentials, the role and scope assignment will be available to OME.

Compatibility matrix 13

For more information about configuring user roles and scopes, see Configure an OpenID Connect provider policy in PingFederate for role section in OpenManage Enterprise User's Guide .

Transfer ownership: The administrator can transfer owned resources from a device manager (source) to another device manager. For example, an administrator can transfer all the resources that are assigned from a source dm1 to dm2. A device manager with owned entities such as policies and EPR can transfer them to another device manager.

For more information see, Transfer of ownership of Device Manager entities section in OpenManage Enterprise User's Guide.

14 Compatibility matrix

4

License requirements

Use OpenManage Enterprise Advanced license together with your iDRAC license to work with all the features of Power

Manager. The following table provides the license combinations that is required to add and monitor servers in Power Manager.

Table 5. License capability with servers

OpenManag e Enterprise

Advanced license iDRAC Base license iDRAC

Express license

Not added Added Not added

Not added

Not added

Not added

Added

Added

Added

Added

Not added

Not added

Not added

Added

Not added

Not added

Not added

Added

Not added

Not added

Not added

Added

Not added

Not added iDRAC

Enterprise license

Not added

Not added

Added

Not added

Not added

Not added

Added

Not added iDRAC Data

Center license

Not added

Not added

Not added

Added

Not added

Not added

Not added

Added

Device and group monitoring

Yes

Yes

Yes

Yes

No

No

No

No

Device and group management

No

No

Yes

Yes

No

No

No

No

The following table provides license information that is required to add chassis for power management through Power Manager.

Table 6. License capability with chassis

Chassis models CMC Enterprise license

PowerEdge VRTX

PowerEdge VRTX

PowerEdge FX2 or PowerEdge FX2s

PowerEdge FX2 or PowerEdge FX2s

PowerEdge M1000e

PowerEdge MX7000

Not added

Added

Not added

Added

NA

NA

Monitoring

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes

Yes

Yes

Power policy Emergency

Power

Reduction

(EPR)

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Licensing behavior in Power Manager for devices:

● If the OpenManage Enterprise Advanced license on the target devices is expired or deleted, the devices are removed from

Power Manager. You must re-add the devices to Power Manager after adding the license.

● If EPR is enabled on a device, and the device is removed from Power Manager due to an expired or deleted license, then you cannot access the device through Power Manager. To disable EPR, go to the iDRAC or CMC page of the device and remove the EPR.

● If policy and alert thresholds are set on a device, and the device is removed from Power Manager due to an expired or deleted license, then the policy and alert thresholds are removed from the device.

Licensing behavior in Power Manager for groups:

● For a group, only the devices that have a valid license are added as part of the group into Power Manager. Metrics are collected only for these devices in the group.

● If the OpenManage Enterprise Advanced license is expired or deleted from the target devices that are part of a group, the devices are removed from Power Manager. After updating the license, these devices are automatically added to Power

Manager in the next inventory cycle.

License requirements 15

● If EPR is enabled on a group, and if the license is expired or deleted for any device in a group, the device is not removed from Power Manager.

● If EPR is enabled on a group, you cannot remove the group or any device that is part of the group from Power Manager.

16 License requirements

5

Scalability and performance

Power Manager supports up to 8,000 target devices that include 500 groups—static and physical groups, servers, virtual machines, and Power Distribution Units (PDUs).

Configure appropriate power and temperature sampling intervals in Power Manager. The sampling intervals impact the system performance and footprint significantly, including network bandwidth consumption, database size, and trend graph display latency.

The default power and temperature intervals in Power Manager are 15 minutes. This value is appropriate for small or mediumsized environments where the device number is less than 1,000. However, when the environment has more managed devices, the interval is automatically set to 30 minutes.

Scalability and performance 17

6

Getting started with Power Manager

Topics:

Install Power Manager

Set preferences

Add devices to Power Manager

Add static groups to Power Manager

Install Power Manager

To monitor power and thermal data for devices or groups, install the Power Manager plugin on OpenManage Enterprise.

Prerequisites

Ensure that the following prerequisites are meet:

● Connectivity to the repository is successful:

○ To connect to an online repository, connect to downloads.dell.com

portal through proxy server, if any, for a secure connection.

○ To connect to an offline repository, ensure that the offline server is configured with required plugin catalog and plugin installation files.

For more details, see OpenManage Enterprise User's Guide.

● Ensure that you have the compatible or latest version of OpenManage Enterprise. To see the list of compatible OpenManage

Enterprise versions with Power Manager, see

Compatibility matrix of Power Manager and OpenManage Enterprise

.

About this task

NOTE: Installing a plugin on OpenManage Enterprise restarts the appliance services.

To install the plugin, perform the following steps:

Steps

1. Launch Dell EMC OpenManage Enterprise, and then click Application Settings > Console and Plugins .

The Console and Plugins page is displayed.

2. In the Power Manager section, click Install .

The Install Plugin page is displayed.

3. Select the plugin version (if there are multiple versions of the plugin that is supported on existing OpenManage Enterprise version) from the Available Version(s) drop-down menu and review to ensure that you meet the list of prerequisites that are mentioned in the Prerequisites section.

NOTE: Only the versions of the plugin that is supported on the installed version of OpenManage Enterprise is listed in the Available Version(s) drop-down menu.

4. Click Download plugin .

The progress of download is displayed, and then the plugin is downloaded and the status of the plugin is updated to

Downloaded on the Console and Plugins page.

5. In Install Details page, click Install plugin .

The Install Plugin window is displayed.

6. Click Install Plugin .

The End User License Agreement window is displayed.

7. Review the agreement and then click Accept option.

18 Getting started with Power Manager

8. The details of the number of users who are logged in to OpenManage Enterprise, tasks in progress, and schedule jobs are displayed in the confirmation window.

To confirm the installation, select the I agree that I have captured a snapshot of the OpenManage Enterprise appliance prior to performing a plugin action.

option, and then click Confirm Install .

The status of the installation is displayed.

● To instantly view the latest list of devices and groups that are part of Power Manager as a result of any license changes made on the target devices, click Run Inventory in OpenManage Enterprise, and then click the Refresh Power

Manager capabilities option on the Power Manager Devices page.

● View the count of overall power-capable devices from the Power Manager Devices Statistics section of the

OpenManage Enterprise dashboard.

Set preferences

The settings on the page enable you to collect data for the devices and groups added to Power Manager. Set the Sampling

Intervals according to your data center recommendations and monitor your devices.

About this task

If you are logging in as a Device Manager, then you can only view the preferences that are configured by an Administrator.

To set the units and sampling intervals, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Settings .

The Settings tab is displayed.

2. Click Edit .

The Edit Power Manager Preferences window is displayed.

3. Select the values for the listed options, and then click Apply .

The following table provides more information about the attributes that are displayed in Power Manager.

Table 7. Power Manager Settings

Field

Data gathering interval

Description

Select the frequency to collect data from devices or groups.

Use your data center requirements such as network traffic, and criticality of data to set the data gathering interval.

NOTE: If you have set the data gathering interval as

15 minutes, and only when the number of devices that are added to Power Manager exceeds 1000, the interval automatically changes to 30 minutes. You cannot return this 30 minutes setting to 15 minutes.

Duration of top energy consumers

Report Duration

Aggregation Period

Delete Power Manager data

Select the duration to view the list of devices or groups that consume maximum energy on the OpenManage Enterprise dashboard for the selected duration.

Only the top five energy consumers are displayed.

View data for the selected duration.

Select the frequency of the level of detailed information that has to be displayed in reports.

NOTE: If you select a Report Duration other than 1

Day, the Aggregation Period is automatically set to 1

Day .

Based on your data requirements, select one of the options:

Getting started with Power Manager 19

Table 7. Power Manager Settings (continued)

Field Description

● Yes —To delete configured alert thresholds and metric data that is collected from devices and groups when they are removed from Power Manager.

● No —To retain the configured alert thresholds and metric data that is collected from devices and groups when they are removed from Power Manager.

NOTE: When you add a device or group and set Delete

Power Manager data to No , all Power Manager-related data for that device or group is removed from view but not deleted, when you remove the device or group from

Power Manager. When you re-add the device or group, data for that device or group is available again.

NOTE: To delete the data after a specific duration, configure the Data purge interval option present in the following location: OpenManage Enterprise > Application Settings > Console Preferences > Metrics Collection Settings .

The following table provides further information about the mandatory fields and the value range for each field.

Table 8. Details about mandatory data intervals and duration

Field

Power Unit

Mandatory

Yes

Watt is the default unit.

Temperature Unit

Data gathering interval

Yes

Celsius is the default unit.

Yes

The default value is 15 minutes.

Value Range

● Watt

● BTU/Hr

● Celsius

● Fahrenheit

Duration of top energy consumers

Report Duration

Aggregation Period

Yes

The default value is 3 Months .

Yes

The default value is 3 Months .

Yes

The default value is 1 Day .

● 15

● 30

● 60

● 1 Day

● 7 Days

● 15 Days

● 1 Month

● 3 Months

● 6 Months

● 1 Year

● 1 Day

● 7 Days

● 15 Days

● 1 Month

● 3 Months

● 6 Months

● 1 Year

1 Day

Delete Power Manager data Yes

The default value is No .

● Yes

● No

20 Getting started with Power Manager

Add devices to Power Manager

To collect and monitor power and thermal utilization, and airflow data of devices, add the devices in Power Manager.

Prerequisites

Ensure that the following prerequisites are met:

● The devices have OpenManage Enterprise Advanced and the required management console licenses. For more information, see the

License requirements .

● Devices are discovered in OpenManage Enterprise. For information about discovering devices, see OpenManage Enterprise

User's Guide .

● The modular server is not in a Proxied state in OpenManage Enterprise.

About this task

To view the list of devices that are compatible with Power Manager, before running the inventory in OpenManage Enterprise and immediately after the installation, perform the following steps:

1. In OpenManage Enterprise, click Devices > Run Inventory option.

2. Click Plugins > Power Management > Power Manager Devices > Refresh the list for Power Manager capabilities option.

The list of devices compatible with Power Manager is displayed when you start to add the devices from OpenManage

Enterprise.

To add devices, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Power Manager Devices .

The Power Manager Devices tab is displayed.

2. Click Individual Devices > Add device(s) .

The Add Devices to Power Manager page is displayed.

3. View all the devices that are discovered in OpenManage Enterprise by expanding the SYSTEM GROUPS section on the left side and in the All Devices tab, select the devices that you want to add.

4. Optional: To filter and view the data: a. Click Advanced Filters .

The following filters are displayed:

● Health State

● Power State

● Connection State

● Name

● Identifier

● Model

● Type

● Managed State

5. Optional: To clear the filters, click Clear All Filters .

6. To view the selected devices, click the Selected Devices tab.

7. To add the devices, click Add Selected .

All the devices added individually to Power Manager are displayed on the Individual Devices tab along with the total count of devices that are added to Power Manager.

All the individual devices and devices that are part of the selected group, are added to Power Manager and are displayed on the All Monitored Devices tab along with the total count of devices.

Results

After adding the devices and groups in Power Manager the following changes are added:

Getting started with Power Manager 21

● After adding the devices or groups to Power Manager, if the server is running iDRAC version 4.40.40.0 or above (and is a

supported model

), Power Manager automatically enables the iDRAC’s Telemetry Streaming configuration and creates a custom Metric Report Definition for collecting data from servers.

● If the added device host Virtual Machines (VMs) and the hypervisors are compatible with Power Manager, then the VMs are listed in the Power Manager Devices tab. For information about viewing VMs, see

View virtual machines . For the list of

compatible operating systems for monitoring VMs, see

Virtual Machines

Add static groups to Power Manager

To collect and monitor custom static group data, add the groups in Power Manager.

Prerequisites

Ensure that the following prerequisites are met:

● Static groups are created in OpenManage Enterprise. For information about creating groups, see OpenManage Enterprise

User's Guide .

● The servers that are part of a group must have an OpenManage Enterprise Advanced license. For information about adding the license, see OpenManage Enterprise User's Guide .

● Modular servers that are part of the group are not in a Proxied state in OpenManage Enterprise.

● It is recommended that each group contains less than or equal to 40 devices.

● The maximum number of groups that you can add to Power Manager is 500.

● The maximum level of group nesting is 5.

About this task

NOTE: Query groups that are created in OpenManage Enterprise are not supported in Power Manager.

NOTE: After adding a group into Power Manager, only devices that are compatible with Power Manager are added as part of the group. Hence, the data is collected only for these devices in a group. For example, if a group you have added to

Power Manager consists of five devices, but only three devices have valid licenses, only three devices are added as part of the group in Power Manager.

To add groups, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Power Manager Devices .

The Power Manager Devices tab is displayed.

2. On the Static Groups tab, click Add Group(s) .

The Add Groups to Power Manager page is displayed.

3. On the left pane, select a group from the Static Groups category and click Add Selected .

The groups added to Power Manager are displayed on the Groups page along with the total count of groups added.

All the individual devices and devices that are part of the selected group, are added to Power Manager and are displayed on the All Monitored Devices tab along with the total count of devices.

Results

If you have created static groups and added devices to OpenManage Enterprise groups and then installed Power Manager, the total number of servers present in the groups is displayed as zero, after adding the groups in Power Manager. Hence, click the

Refresh the list for Power Manager capabilities option on the Power Manager Devices tab after running an inventory in

OpenManage Enterprise.

For more information about running an inventory, see OpenManage Enterprise User's Guide .

After adding the devices or groups to Power Manager, if the server is running iDRAC version 4.40.10.0 or above (and is a supported model), Power Manager automatically enables the iDRAC’s Telemetry Streaming configuration and creates a custom

Metric Report Definition for collecting data from servers. For list of supported models, see Dell EMC OpenManage Enterprise

Power Manager User's Guide.

22 Getting started with Power Manager

7

Create a device discovery job

About this task

NOTE: To perform any tasks in Power Manager, ensure that you have necessary user privileges. For more information, see

Role and scope based access control in OpenManage Enterprise

.

To discover a device:

Steps

1. Launch OpenManage Enterprise and click Monitor > Discovery > Create .

The Create Discovery Job dialog box is displayed.

2. In the Create Discovery Job dialog box, a default job name is populated. To change it, enter the discovery job name.

By default, the dialog box enables you to define properties of similar devices at a time.

● To include more devices or ranges to the current discovery job, click Add . Another set of the following fields is displayed where you can specify the device properties: Type, IP/Hostname/Range, and Settings.

WARNING: A maximum of 8,000 devices can be managed by OpenManage Enterprise. Hence, do not specify large networks that have devices more than the maximum number of devices supported by

OpenManage Enterprise. It may cause the system to abruptly stop responding.

NOTE: When discovering a large number of devices, avoid creating multiple discovery jobs using individual IP address and instead use IP range of the devices.

3. From the Device Type drop-down menu, to discover:

● A server, select SERVER . See Specifying discovery mode for creating a server discovery job section in OpenManage

Enterprise User's Guide.

● A chassis, select CHASSIS . See Specifying discovery mode for creating a chassis discovery job section in OpenManage

Enterprise User's Guide.

● A Dell EMC storage device, or network switch, select DELL STORAGE , or NETWORKING SWITCH . See Specifying discovery mode for creating a storage, Dell storage, and network switch discovery job section in OpenManage Enterprise

User's Guide.

● A Power Distribution Unit (PDU) device, select PDU .

NOTE: Only after installing or enabling Power Manager you can view the PDU device type option.

● To discover various devices by using multiple protocols, select MULTIPLE .

4. In the IP/Hostname/Range box, enter the IP address, hostname, or the range of IP address to be discovered or included.

For more information about the data you can enter in this field, click the i symbol.

NOTE:

● The range size is limited to 16,385 (0x4001).

● IPv6 and IPv6 CIDR formats are supported.

5. In the Settings section, enter the username and password of the protocol that is used for discovering the ranges.

6. Click Additional Settings , to select a different protocol, and change the settings.

NOTE: Ensure you select the SNMP protocol to discover PDU devices.

7. In the Scheduling Discovery Job section, run the job immediately or schedule for a later point of time. See

Schedule job field definitions on page 24.

8. Select the Email when complete check box, and then enter the email address that must receive notification about the discovery job status. If the email is not configured, the Go to SMTP Settings link is displayed. Click the link, and configure the SMTP settings. If you select this but do not configure SMTP, the Finish button is not displayed to continue the task.

9. Click Finish . The Finish button is not displayed if the fields are incorrectly or incompletely filled.

A discovery job is created and run. The status is displayed on the Job Details page.

Topics:

Create a device discovery job 23

Schedule job field definitions

Create customized device discovery job protocol for SNMP devices

Schedule job field definitions

● Run now to start the job immediately.

● Run Later to specify a later date and time.

● Run On Schedule to run repeatedly based on a selected frequency. Select Daily , and then select the frequency appropriately.

NOTE: By default, the job scheduler clock is reset at 12:00 A.M. everyday. The cron format does not consider the job creation time while calculating the job frequency. For example, if a job is started at 10:00 A.M. to run after every 10 hours, the next time the job runs is at 08:00 P.M. However, the subsequent time is not 06:00 A.M. next day but 12:00 A.M. This is because the scheduler clock is reset at 12:00 A.M. everyday.

Create customized device discovery job protocol for

SNMP devices

About this task

By default, the Discover using SNMP check box is selected to enable you detect the storage, networking, or other SNMP devices.

NOTE: Only the IO Modules with Standalone, PMUX (Programmable MUX), VLT (Virtual Link Trunking) Modes are discoverable. Full switch and Stacked Modes will not be discovered.

Steps

1. Under Credentials , select the SNMP version, and then enter the community type.

2. In the Connection Settings section: a. In the Retries box, enter the number of repeated attempts that must be made to discover a server.

b. In the Timeout box, enter the time after which a job must stop running.

c. In the Port box, enter the port number that the job must use to discover.

NOTE: The settings in the Retries box and the Timeout box do not have any functional impact on the discovery jobs for SNMP devices. Hence, these settings can be ignored.

3. Click Finish .

4. Complete the tasks in Creating a device discovery job . For more information, see OpenManage Enterprise User's Guide.

24 Create a device discovery job

8

Monitor and manage Power Manager devices

This section provides high-level information to help administrators get started with Power Manager.

Prerequisites

Ensure that the following prerequisites are met:

● The devices are compatible with Power Manager. For more information, see

List of supported devices .

● Discover the devices in Dell EMC OpenManage Enterprise.

For more information about discovering devices, see OpenManage Enterprise User's Guide .

● For more information about creating static groups, see OpenManage Enterprise User's Guide .

● Add the OpenManage Enterprise Advanced and the management console licenses on the target devices.

For more information about adding a license, see the respective management console guide.

To monitor the data of devices and groups, perform the following steps:

Steps

1. Create static custom groups or physical groups in OpenManage Enterprise.

For more information about creating static groups under CUSTOM GROUPS , see OpenManage Enterprise User's Guide .

For more information about creating physical groups under PLUGIN GROUPS , see

Creating physical groups .

The physical groups that are created or deleted in OpenManage Enterprise are automatically added or removed from Power

Manager.

If you have created a physical group: a. Add the

unmonitored devices in Power Manager.

b. Add the

individual devices and unmonitored devices

in physical groups.

2. Add the supported

individual devices

, or static groups

to Power Manager.

3. Configure your preferences in Power Manager using the Settings page. For more information, see

Setting preferences

.

4. After adding devices and groups to Power Manager, you can perform the following tasks:

● View all the device or group

metrics details

using Metrics and Monitoring History .

Create and apply Power policies

to regulate the power consumption on devices or groups.

Create and apply Temperature-triggered policies

to regulate device temperature.

● During a power emergency, reduce power consumption using the

Emergency Power Reduction feature.

● Create

alert thresholds in Power Manager by configuring the warning and critical values for devices or groups that are

monitored in Power Manager.

● Run the built-in or customized

reports to view in-depth information about the devices or groups, jobs, alerts, and other

parameters of your data center.

● View and acknowledge

alerts that are generated in OpenManage Enterprise through Power Manager in

Alerts > Alert

Logs .

● View and monitor virtual machines that are hosted by hypervisors. For more information, see

Virtual machines .

● View generic Power Manager logs generated in OpenManage Enterprise through Monitor > Audit Logs tabs.

Topics:

View metrics, and monitor devices and groups history

Virtual machines

Thresholds

Policies

Monitor and manage Power Manager devices 25

View metrics, and monitor devices and groups history

View the visual representation of the data that is collected for all devices and groups that are added to Power Manager.

Prerequisites

Ensure that the following prerequisite is met:

● Devices or groups are added to Power Manager. For more information, see

Adding devices to Power Manager

and

Adding groups to Power Manager

.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view the device metrics only for the groups and devices in Device Manager DM1 user scope.

To view Power Manager metrics, perform the following steps:

Steps

1. From OpenManage Enterprise, perform one of the following steps:

● For a device: a. Click the Devices tab.

All the devices that are discovered in OpenManage Enterprise are displayed.

b. From the list of devices, click a device name.

The details of the device are displayed on the Overview page.

c. To view Power Manager-related information, click the Power Management and Monitoring tab.

● For a static group: a. Click Devices > Static Groups > Group name .

All the devices that are part of the static group are displayed.

b. To view Power Manager-related information, click Group Details .

● For a physical group, perform one of the following steps: a. Click Devices > Physical Hierarchy > Group name .

All the devices that are part of the physical group are displayed.

b. To view Power Manager-related information, click Group Details .

OR a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View tab is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

○ Group Name

○ Health State

○ Power State

○ Connection State

○ Type

Select the categories of your choice and view the filtered data.

b. Click the device name or IP address.

2. View metrics and monitoring data in the Metrics and Monitoring History tab.

NOTE: For groups, only power, thermal, and system airflow data are displayed.

The supported metric data is displayed in a graphical format.

26 Monitor and manage Power Manager devices

3. To change the duration, expand the metric and select a duration from the Duration drop-down menu. Hover your mouse pointer over the graph to view the maximum, average, and minimum values.

The values are displayed according to the format that you have specified in the Monitoring Units and Metric gathering interval in the Power Manager Preferences section.

NOTE: You can view only Instant temperature for PowerEdge M1000e, PowerEdge FX2, and PowerEdge FX2s chassis.

NOTE: You can view only the power, temperature, and system airflow history for PowerEdge AMD processor servers.

Based on your selection, details of the granular information available are as follows:

Table 9. Granularity of data

Duration

6 Hours or 12 Hours or 1 Day

7 Days or 1 Month

3 Months or 6 Months or 1 Year

Granularity of data

Data is displayed based on the Metric gathering interval set in the Preferences section.

Data is displayed at an interval of one hour.

Data is displayed at an interval of one day.

4. To view the latest metrics, click the refresh icon.

Table 10. List of Power Manager metrics and supported devices

Metric

Power History (Watt)

Supported devices

● 12 th and later generations of PowerEdge servers

NOTE: Cabled PSU servers are not supported.

Energy Consumption

Thermal History (Celsius)

CPU Utilization (%)

I/O Utilization (%)

Memory Bandwidth Utilization (%)

System Airflow History (CFM)

NOTE: PowerEdge Fm120 aqua is not supported.

● PowerEdge MX7000

● PowerEdge M1000e

● PowerEdge VRTX

● PowerEdge FX2

● PowerEdge FX2s

● 12 th and later generations of PowerEdge servers

● PowerEdge MX7000

● PowerEdge M1000e

● PowerEdge VRTX

● PowerEdge FX2

● PowerEdge FX2s

● 12 th and later generations of PowerEdge servers

● PowerEdge MX7000

● PowerEdge M1000e

● PowerEdge VRTX

● PowerEdge FX2

● PowerEdge FX2s

● 13 th and later generations of PowerEdge Intel servers

● 15 th and later generations of PowerEdge AMD servers with iDRAC version 4.30.30.30 and later

● 13 th and later generations of PowerEdge servers (Intel)

● 13 th and later generations of PowerEdge servers (Intel)

● Nonmodular PowerEdge servers

○ The latest generation of AMD servers with iDRAC

Data Center license and iDRAC version 4.10.10.10 and above

Monitor and manage Power Manager devices 27

Table 10. List of Power Manager metrics and supported devices (continued)

Metric Supported devices

NOTE: 14 th generation AMD servers with iDRAC version 4.10.10.10 and above.

Virtual machines

Discovery feature discovers the hypervisors hosting virtual machines (VM) along with host servers. The virtual machines are listed in Guest Information section in OpenManage Enterprise. After adding the servers in Power Manager, the required hypervisor settings are automatically enabled by Power Manager to retrieve data that is related to virtual machines from the servers and the virtual machines are listed on the Power Manager Devices tab.

Hypervisors do not directly provide the power and energy consumption details of the VMs. Hence, Power Manager collects the

CPU usage data for each VM in the host and approximately calculates the power and energy that is consumed by the server to the individual VMs in the host. Use this feature to view resource consumption of each VM and to monitor and manage the servers hosting the VMs.

The following table lists the various operating system versions that are supported in Power Manager for monitoring virtual machines.

Table 11. Operating Systems and the supported versions

Operating System Supported Versions

Microsoft Windows Hypervisors Microsoft Windows 2022

VMware ESXi

Microsoft Windows 2019

Microsoft Windows 2016

ESXi 7.0

ESXi 7.0 U1

ESXi 6.7 U3

A VM is identified using a unique identifier, UUID for each VM. The list of VMs and their information is refreshed with each metric collection. If a new VM is created, or deleted, this information is reviewed in the next cycle. If the VM is migrated to another server, and if this new server is added to Power Manager, the VM is identified as same using the UUID and the metrics collection continues for the VM. In case the UUIDs do not match then the VM is detected as a new VM and Power Manager starts collecting the data as a new VM.

A VM cannot be added or removed manually from Power Manager. Only if the host server is added to Power Manager, the

VMs are automatically added to Power Manager. And, if the host server is removed from Power Manager or deleted from

OpenManage Enterprise, the VM is automatically removed from Power Manager.

View virtual machines

View all the virtual machines (VM) added in Power Manager.

Prerequisites

Before viewing the virtual machines, ensure the following:

● The server (iDRAC) and the hypervisor (host operating system) are discovered in OpenManage Enterprise.

● The correlation of the discovered server and the hypervisor is successful.

● The credentials provided to discover the hypervisor have Administrator privileges.

● The server is added in Power Manager. To add a server to Power Manager, ensure that you have the required licenses. For more information, see

License requirements

.

28 Monitor and manage Power Manager devices

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, and a group G1 is assigned to the Device Manager DM1 user, you can view only the virtual machines that are hosted by the devices in the G1 group.

Steps

1. Launch OpenManage Enterprise and click Plugins > Power Management > Power Manager Devices .

The Power Manager Devices tab is displayed.

2. To view the virtual machines monitored in Power Manager, expand the Virtual Machines section on the left pane.

3. To view details of a particular VM, click a VM name.

A section with all the VM details is displayed on the right pane.

4. To view the power history of a VM, click View Metrics .

The power history of the server and the VM are displayed.

5. To change the duration, expand and select the required duration from the Duration drop-down menu.

Hover your mouse pointer over the graph to view the device and VM power at a certain time.

6. To view the latest metrics, click the refresh icon.

Next steps

After migrating VMs from source to target server, if you create a VM on the source server, then the same UUID that was allotted to the migrated VM may get assigned to the new VM. Hence, you may not see the VMs displayed in Power Manager, if both the source and target servers are monitored. To view and monitor all the VMs hosted on servers that are monitored by

Power Manager, check and delete the VMs with conflicting UUIDs.

To view the UUIDs of VMs, perform the following steps:

1. Launch OpenManage Enterprise and click Devices .

2. Click a device name.

The device Overview page is displayed.

3. Click Hardware tab and then click Guest Information .

The VM Guest information is displayed.

Thresholds

Thresholds enable you to specify warnings and critical limits for power and temperature metrics on devices and groups. Power

Manager generates alerts through OpenManage Enterprise when the configured limits are violated. The status of power and temperature are displayed in the form of graphs on the Power Management and Monitoring or Group Details tab.

Create alert thresholds

To monitor devices and groups for threshold violations, define the power and temperature threshold values.

Prerequisites

Ensure that you have added devices or groups to Power Manager.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can create and manage alert thresholds that are created by any other Device Manager user only for the devices in Device Manager DM1 user scope.

To configure alert thresholds for power and temperature, perform the following steps:

Monitor and manage Power Manager devices 29

Steps

1. From OpenManage Enterprise, perform one of the following steps:

● For a device: a. Click the Devices tab.

All the devices that are discovered in OpenManage Enterprise are displayed.

b. From the list of devices, click a device name.

The details of the device are displayed on the Overview page.

c. To view Power Manager-related information, click the Power Management and Monitoring tab.

● For a static group: a. Click Devices > Static Groups > Group name .

All the devices that are part of the static group are displayed.

b. To view Power Manager-related information, click Group Details .

● For a physical group, perform one of the following steps: a. Click Devices > Physical Hierarchy > Group name .

All the devices that are part of the physical group are displayed.

b. To view Power Manager-related information, click Group Details .

OR a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View tab is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

○ Group Name

○ Health State

○ Power State

○ Connection State

○ Type

Select the categories of your choice and view the filtered data.

b. Click the device name or IP address.

2. To set thresholds, click the Alert Thresholds tab, and click Edit .

The Edit Alert Thresholds page is displayed.

3. Provide threshold values for Power and Temperature .

NOTE: When the alert threshold value units are set for power in BTU/Hr and temperature in Fahrenheit , ensure that you provide only the values and no other special character as the value may change after saving.

When the power or temperature values exceed the lower or upper warning values, a warning-level alert is generated and forwarded to OpenManage Enterprise.

When the power or temperature value exceeds the lower or upper critical values, a critical-level alert is generated and sent to OpenManage Enterprise.

4. Click Apply to save the values.

The thresholds are saved successfully, and the scales are color-coded based on the current state of the device or group.

See the following tables for each threshold value range.

Table 12. Alert threshold range details for Watt and Celsius scale

Field

Power (Watt)

Mandatory

Upper Warning

Upper Critical

Temperature (Celsius)

Lower Critical

No

No

No

Value Range

Limit: 1–29307121 integers

Limit: 1–29307121 integers

Limit: -10 to 60 degrees

30 Monitor and manage Power Manager devices

Table 12. Alert threshold range details for Watt and Celsius scale (continued)

Field

Lower Warning

Mandatory

No

Value Range

Limit: -10 to 60 degrees

Upper Warning

Upper Critical

No

No

Limit: -10 to 60 degrees

Limit: -10 to 60 degrees

Table 13. Alert threshold range details for BTU/hour and Fahrenheit scale

Field

Power (BTU/hour)

Mandatory Value Range

Upper Warning

Upper Critical

Temperature (Fahrenheit)

Lower Critical

Lower Warning

Upper Warning

Upper Critical

No

No

No

No

No

No

Limit: 3–99937283 integers

Limit: 3–99937283 integers

Limit: 14-140 degrees

Limit: 14-140 degrees

Limit: 14-140 degrees

Limit: 14-140 degrees

Policies

Power Manager supports two types of policies you can use to monitor the power and temperature of your data center devices.

Static policy

A static policy contains various settings that help regulate the power consumption of a specific device or a group. A power management policy is useful in different situations. For example, you can create a policy to:

● Ensure that power consumption does not exceed the capacity of the circuit.

● Schedule power usage according to the workload of the device or group For example, to reduce the overall power use in your data center, apply an aggressive power cap policy when the workload is low.

● Increase rack density. For example, to increase the rack density or number of devices in a group you can set a power cap at a group level and add more servers. The policy cap keeps the power within the defined limit.

Temperature-triggered policy

A temperature-triggered policy is used to prevent damage to devices due to overheating in the event of cooling infrastructure failure. It limits the processing capability of the devices in the group, hence reducing the heat generation. The policy helps in maintaining the data center temperature to align to the standards defined by the American Society of Heating, Refrigerating and

Air-Conditioning Engineers (ASHRAE). Create a temperature-triggered policy on a group of devices by defining a temperature threshold value. After defining the threshold value and enabling the policy, if the average inlet temperature of the group crosses the temperature threshold value, Power Manager enforces an EPR—Throttle on the group. On the EPR page, the source of

EPR is displayed as Temperature-triggered—Throttle on the group.

NOTE: Temperature-triggered policies are applicable only for groups, and only one temperature-triggered policy is supported for a group.

NOTE: After applying a policy on a group, if you add more devices to the group and the power consumption exceeds the power cap, then you receive alerts in Alert Log with the recommended action.

Monitor and manage Power Manager devices 31

In multiple policies scenario, an active policy with a power cap value of 1000 Watts is applied on a device, and then another active policy with a power cap value of 1500 Watts is applied on the same device, the policy with power cap value of 1000 Watts is applied on the device as this policy is the most restrictive policy.

Create static or temperature-triggered policy

Create a static policy to limit the power consumption for devices and groups or apply EPR on devices in a group when the average inlet temperature exceeds the temperature threshold.

Prerequisites

Ensure that the following prerequisites are met:

● Devices or groups are added to Power Manager.

● Servers have the iDRAC and OpenManage Enterprise Advanced licenses.

○ If a device is PowerEdge VRTX or PowerEdge FX2 chassis, it has a Chassis Management Controller (CMC) Enterprise license.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can create policies on devices and groups that are in

Device Manager DM1 user scope.

When Device Manager users have common groups or devices in their scope, and Device Manager DM1 user creates a policy on any of these groups or devices:

● All the policies that are created by Device Manager DM1 user are not listed for other Device Manager users.

● If the Device Manager DM1 user creates a temperature-triggered policy on a group, the Device Manager DM2 user cannot create a temperature-triggered policy on the same group since only one temperature-triggered policy is supported on a group. And, the temperature-triggered policy is not visible or listed for Device Manager DM2 user. However, if the Device

Manager DM2 user has to create a temperature-triggered policy on this group, ensure that the Device Manager DM1 user or the Administrator deletes the existing temperature-triggered policy.

To create a policy, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Policies .

The Policies tab is displayed.

2. Click Create .

The Create Policy wizard is displayed.

3. In the General section, provide the following information and click Next .

a. In Type , select the type of policy.

● Static policy —applies a cap on the power consumption of a device or group.

● Temperature-triggered policy —applies Emergency Power Reduction (EPR) on a group of devices when its temperature equals or exceeds a specified value.

NOTE: After a policy is created, you cannot change the type of policy.

To activate the policy after creation, the Enable option is selected by default.

b. Provide a policy name and description.

4. In the Devices/Groups section, select the required option:

● To add a device: a. Select the Device option and click Select Device .

The Select Device page is displayed.

b. Click Advanced Filters .

The following filters are displayed:

● Health State

● Power State

32 Monitor and manage Power Manager devices

● Connection State

● Name

● Identifier

● Model

● Type

● Managed State

● Part of Group c. Select the device, and click Add Selected .

● To add a group: a. Select the Group option and click Select Group .

The Select Group page is displayed.

b. Click Advanced Filters .

The following filters are displayed:

● Name

● Type c. To clear the filters, click Clear All filters .

d. Select the group and click Add Selected .

NOTE: You can select only one device or group when creating a policy.

NOTE: After you create a policy for a device, you cannot apply the policy to a group. Similarly, after creating a policy for a group, you cannot apply the policy to a device.

5. Click Next .

6. For a static policy:

In the Policy Settings section, select the monitoring period from the Monitoring time period drop-down menu, and provide the Power cap value, and then click Next .

Use the Power History section as a reference to set the power cap value.

● Power History for a device—displays minimum, average, and maximum power consumption with the lower and upper bound values. The values change as you change the duration of the Monitoring time period .

● Power History for a group—displays minimum, average, and maximum power consumption with lower and upper bound values. The minimum, average, and maximum power history of the group is the sum of all the minimum, average, and maximum power consumption of individual devices in the group. The values change as you change the duration of

Monitoring time period . The upper and lower bound value for a group is the sum of upper bound and lower bound values for all devices part of the group. The Power Cap displayed is the sum of all the power cap values of the devices in the group.

Guidance for providing power cap values:

● The default Power Cap Value displayed is the upper bound value of the device. You can change the Power Cap value and the Power Cap percentage gets populated automatically.

● If you change the percentage of Power Cap then the Power Cap value gets populated automatically.

● If you change the Percentage of Range then the Power Cap Value gets populated automatically.

● For groups, provide the power cap value or percentage of consumption at the group level or at every device level.

● Provide the power cap value that ranges between the lower and upper bounds of the device.

NOTE: For the following list of PowerEdge servers, the Lower Bound and Upper Bound threshold range values are always static.

Table 14. Power cap range for servers

Generation of servers

14 th generation

Models

● PowerEdge XE7440

● PowerEdge XE7420

● VxRail G560

● VxRail G560F

● PowerEdge C6420

● PowerEdge R6415

● PowerEdge R7415

Value Range (Watts)

Zero to 32767

Monitor and manage Power Manager devices 33

Table 14. Power cap range for servers (continued)

Generation of servers Models

● PowerEdge R7425

13 th generation ● PowerEdge C6320

● PowerEdge C6320p

Value Range (Watts)

Zero to 700

For a temperature-triggered policy:

In the Policy Settings section, select a monitoring period from the Monitoring time period drop-down menu, select or provide the Temperature Threshold value, and then click Next .

Use the Temperature data section as a reference to set the temperature threshold value. Based on your selection of the

Monitoring time period value, the temperature summary details are displayed.

● The values change as you change the duration of the Monitoring time period .

● Select your preferred American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) temperature threshold from the Temperature Threshold drop-down menu. Based on your ASHRAE class selection, the temperature value is populated.

Select the ASHRAE standard relevant in your region or provide a custom value in Celsius only.

○ ASHRAE Recommended — 27°c (81°f)

○ ASHRAE Class A1 Allowable —32°c (90°f)

○ ASHRAE Class A2 Allowable — 35°c (95°f)

○ ASHRAE Class A3 Allowable — 40°c (104°f)

○ ASHRAE Class A4 Allowable —45°c (113°f)

● You can also provide a custom temperature threshold value.

7. In the Policy Schedule section, provide the following information and click Next .

Power Manager enables you to create and apply multiple policies on a specific device or group. In any instance, if multiple policies are active on a device, either by policies set on the device or by policies set on the group the device is a part of, the most restrictive power cap among the policies is applied on the device.

a. For the Time Span option, select Always for the policy to be active from the time of creation. If the policy does not have to be active always when enabled, click Range and provide a time range during which the policy must be active when it is enabled.

b. For the Day(s) option, select Always for the policy to be active from the time of creation. If the policy does not have to be active always when enabled, click Daily , to select specific days on which the policy must be active when it is enabled.

c. For the Active Date option, select the date range during which the policy must be active when enabled.

NOTE: A temperature-triggered policy cannot be scheduled.

8. In the Summary section, view the policy details and click Finish .

The policy is created successfully.

The following table provides more information about all the fields in the policy wizard.

Table 15. Policy wizard details

Field

Type

Mandatory

Yes

By default, the type is selected as Static .

Name Yes

Value Range

● Static policy

● Temperature-triggered policy

Description No

Combination of characters, special characters, and numbers

Limit: 1–255 characters

Combination of characters, special characters, and numbers

34 Monitor and manage Power Manager devices

Table 15. Policy wizard details (continued)

Field

Enable

Monitoring time period

For static policy

Power cap

Time Span

Day(s)

Active Date

For temperature-triggered policy

Temperature Threshold

Mandatory

No

By default, the check-box is selected.

Value Range

Limit: 0–255 characters

Select

Clear

Yes

By default, the time period is selected as 1 Day .

● 1 Day

● 7 Days

● 1 Month

● 3 Months

Yes

By default, the power cap is populated with the Upper

Bound value and a hundred percent.

Yes

By default, the option is selected as Always .

Yes

By default, the option is selected as Always .

Yes

By default, the option is selected as Always .

Recommended limit: Lower

Bound Upper Bound

Range Limit: 12 hours format

Daily Select at least one day.

Range

● From

● To

Limit: Current and future dates

Yes

By default, the option that is selected is ASHRAE

Recommended .

● Custom value range: -10 to 60 degrees

● ASHRAE

Recommended

● ASHRAE Class A1

● ASHRAE Class A2

● ASHRAE Class A3

● ASHRAE Class A4

Monitor and manage Power Manager devices 35

9

Rack management

Manage the physical groups hierarchy, and perform rack utilization for space and power using rack management features.

Prerequisites

Ensure that the following prerequisites are met:

● The devices have OpenManage Enterprise Advanced and the required management console licenses. For more information, see the

License requirements .

● Devices are discovered in OpenManage Enterprise. For information about discovering devices, see OpenManage Enterprise

User's Guide .

● The modular server is not in a Proxied state in OpenManage Enterprise.

About this task

To monitor and manage racks in your data center, perform the following steps:

Steps

1. Create the

physical groups

to replicate the group hierarchies in a data center.

2. Add the unmonitored devices

in Power Manager.

3. Add the individual devices and unmonitored devices

in physical groups.

4. View Power Manager details like group metrics, policy applied, power and space headroom data, by expanding Physical

Hierachy to a group level and click Group Details .

5. Associate Power Distribution Units (PDUs) to rack. For more information, see

associate PDU to rack .

6. Monitor PDU information. For more information, see View PDUs

.

Topics:

Add unmonitored device details

Add or edit device details for Power Manager monitored devices

Create physical groups

Power Distribution Unit

Add unmonitored device details

Unmonitored devices are user-defined or non-compatible devices that must be considered for accurate rack management. The unmonitored devices are not monitored for any Power Manager capabilities such as power, thermal monitoring, power policy and

EPR, and alert thresholds.

About this task

Add the details of the unmonitored devices in Power Manager to replicate the physical group hierarchy present in your data center and manage the racks.

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can only view and cannot edit the unmonitored devices information that is part of the group in Device Manager DM1 user scope.

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Power Manager Devices >

UNMONITORED > Unmonitored Devices .

The Unmonitored Devices tab is displayed.

36 Rack management

2. To add the Unmonitored Devices, click Add .

The Add Unmonitored Devices page is displayed.

3. Provide the device details and click Finish .

For information about each field, see the following table.

Table 16. Details for Unmonitored Devices

Field Description

Device Name Provide a unique device name.

Mandatory

Yes

Description

Hostname

Identifier

Model

Provide brief information about the device you are adding.

No

Provide a hostname.

No

Provide a unique identifier for the device.

Yes

Provide the model name.

No

Value Ranges

Combination of characters, special characters, and numbers.

Limit: 1-255 characters

Combination of characters, special characters, and numbers.

Limit: 0-255 characters

Combination of characters, special characters, and numbers.

Limit: 1-255 characters

Combination of characters, special characters, and numbers.

Limit: 1-255 characters

Combination of characters, special characters, and numbers.

Limit: 0-255 characters

Numbers only

Limit: 1-80

Numbers only

Limit: 1–629365631

Size of Device (U) Provide the space occupied on the rack.

Yes

Estimated Max Power (W) Provide the defined maximum power that the device can consume.

No

Add or edit device details for Power Manager monitored devices

Add device details for devices monitored through Power Manager for accurate rack management.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view and edit the device details that are part of groups that are in Device Manager DM1 user scope. However, as a Device Manager DM1 user, you cannot add any device to the group in your scope.

To add or edit the device details, perform the following steps:

Rack management 37

Steps

1. Launch OpenManage Enterprise.

2. On the Devices page, select a device by clicking anywhere on the row except on the Name and IP Address columns.

3. Scroll down to the end of the page to view the Device Details for Power Manager section on the bottom-right side of the page.

4. Click Update Details .

The Device Details for Power Manager page is displayed.

5. Provide the size of the device in the rack Unit and maximum power consumption of the device in Watts and click Apply .

The power value is automatically converted to BTU and displayed.

The details for the device are updated.

Create physical groups

Power Manager enables you to replicate and update the physical organization and hierarchy of a data center. Using the following hierarchy—Data Center, Room, Aisle, and Rack create the physical groups and add the devices at the rack level.

About this task

Create physical groups by importing a CSV file having the physical group details or replicate your data center hierarchy virtually in Power Manager.

The physical groups that are created or deleted in OpenManage Enterprise are automatically added or removed from Power

Manager.

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view only the devices and groups that are assigned to a Device Manager DM1 user.

Creating physical groups in OpenManage Enterprise

Steps

1. Launch OpenManage Enterprise.

2. On the Devices page, in the left pane, expand the PLUGIN GROUPS section.

3. In the Physical Hierarchy section, click more options, and then click Create New Physical Group .

The Create New Physical Group page is displayed.

4. Provide a name and description for the group, select the Group Hierarchy and Parent Group with the defined power capacity.

When selecting the Group Hierarchy and Parent Group fields, ensure that you use the following hierarchy.

Table 17. Supported parent and child group hierarchy information

Parent Group Group Hierarchy

Data Center

Room

Aisle

Rack

Room, Aisle, Rack

Aisle, Rack

Rack

NA

Table 18. Physical group attributes details

Field Description

Name Provide a unique name for the physical group.

Mandatory

Yes

Value Range

Combination of characters, special characters, and numbers

Limit: 1–255 characters

38 Rack management

Table 18. Physical group attributes details (continued)

Field

Description

Group Hierarchy

Description

Provide brief information about the physical group.

Defines the category under

Parent Group

Mandatory

No

Yes

Parent Group

Power Capacity (W)

Represents the high-level hierarchy for the physical group

Provide the maximum defined power consumption of the physical group.

Yes

Yes, only for the Rack group.

Optional for data center, room, and aisle groups.

Yes Space Capacity (U-SIZE) Provide the rack capacity for rack management purpose.

NOTE: This option is only applicable for

Racks .

Value Range

Combination of characters, special characters, and numbers

Limit: 0–255 characters

● Data Center

● Room

● Aisle

● Rack

● Physical Hierarchy

● Previously created Physical

Groups

Recommended limit: 1–629365631

Recommended limit: 1U – 80U

NOTE: The power capacity and space capacity of the device is updated only in Power Manager and not in iDRAC or

CMC consoles.

Add devices in physical group

Add devices in physical groups for accurate rack management.

Prerequisites

Ensure that the following prerequisites are met:

● Add the size of the unmonitored device that you plan to add to a physical group.

● Emergency Power Reduction (EPR) is not enabled on the group.

About this task

To add devices in a physical group, perform the following steps:

Steps

1. Launch OpenManage Enterprise and perform one of the following steps: a. On the Devices page, in the left pane, expand the PLUGIN GROUPS section.

b. To view the devices, expand the Physical Hierarchy group until a rack level and right-click and select the Manage

Rack option.

The Manage Rack page is displayed.

Or a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View page is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

● Group Name

Rack management 39

● Health State

● Power State

● Connection State

● Type

Select the categories of your choice and view the filtered data.

b. Click the rack name.

The Manage Rack page is displayed.

2. To add devices discovered in OpenManage Enterprise, click Add To Rack Slot .

The Add Device(s) To Rack Slots wizard is displayed.

3. In the Select Device(s) section, select the devices and click Next .

4. Optional: To filter and view the data, perform the following steps: a. Click Advanced Filters .

b. Select your category of filters.

The following filters are displayed for devices:

● Health State

● Power State

● Connection State

● Name

● Size of Device (U)

● Identifier

● Model

● Type

● Managed State

5. In Add device(s) to rack slots , by default, the devices are automatically added in the available slots in the rack. To add a device at a specific slot, select the Auto drop-down menu and select the required slot.

6. Click Finish .

The devices that are added are graphically displayed on the Manage Rack page.

NOTE: The rack slot option is available for a chassis, rack servers, storage, network switches, and unmonitored devices.

To view details of modular servers inside a chassis and details of the connected Input Output Modules (IOM), locate the chassis in the Manage Rack page and hover the pointer at the IP address or device name.

Create physical groups through CSV file

Use the import feature to create physical groups and add devices to rack slots in Power Manager by importing new or existing physical group details through a CSV file, instead of manually creating the physical groups with hierarchies.

About this task

Consider the following points before creating and importing the CSV file:

● Only Administrators can import the CSV files.

● The script checks if the devices are discovered in OpenManage Enterprise.

● Ensure that the physical group you are creating adheres to the hierarchy as follows:

Table 19. Supported hierarchy format

Physical group

Data Center

Supported hierarchies

Room, Aisle, Rack

Room

Aisle

Aisle, Rack

Rack

Rack Not applicable

● When creating a rack in physical group, ensure that you provide the rack name, power capacity, and space capacity.

● Each physical group and their siblings in a physical group hierarchy are identified by a unique name.

● To add a device in the physical group:

40 Rack management

○ Ensure that only one device detail is entered in each row. A device is identified by a unique identifier. The identical devices are ignored while importing, and only the unique devices are added in a rack slot.

○ To place the device in a particular slot, ensure that you provide the rack slot information.

● When you are considering multiple device allocations on the same physical group hierarchy, you can duplicate the fields.

However, only the rack slot and device identifier are unique fields.

● View details about the import job by selecting the Physical Group CSV Import Task job on the Jobs page. You can view the status about each row added in the file on the Execution Details page.

Steps

1. Launch OpenManage Enterprise and click Plugins > Power Management > Power Manager Devices .

The Power Manager Devices tab is displayed.

2. Click Physical Groups and then click Import .

The Import physical groups from CSV file page is displayed.

3. Optional: To view the format of the CSV file, click Download sample file .

A sample CSV file is downloaded which you can use as a reference for adding the groups information.

4. To upload the CSV file and create the physical groups, click Import CSV file .

The groups are created successfully after importing the CSV file for valid entries.

Power Distribution Unit

Power Distribution Unit (PDU) is a device with multiple outlets capable of supplying power to all the devices within a rack. PDUs can be classified into two categories:

● Non-Intelligent PDUs—distribute power evenly to all the outlets.

● Intelligent PDUs—provide advanced monitoring capabilities and remote control.

There are different types of PDU devices available in the market that you can choose from, however Power Manager supports only metered PDUs.

Metered PDUs are intelligent rack PDUs that display power consumption over a secure network. They help Administrators in avoiding overloading the circuits and in calculating the Power Usage Effectiveness (PUE), provide accurate power usage, and available capacity at rack level. Also, they help in identifying the power consumption at server and various device levels to charge the customers of a data center as per their usage.

Associate PDU to rack

Associate the respective Power Distribution Unit (PDU) devices to a rack to monitor accurate power consumption.

Prerequisites

Ensure that the PDU devices are discovered in OpenManage Enterprise.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager user, you can only view the PDU devices added to the group defined in your scope. You cannot associate any PDUs to a group.

Steps

1. Launch OpenManage Enterprise and perform one of the following steps:

● Click Plugins > Power Management > Rack View , and then right-click and select Manage Rack option.

The Manage Rack page is displayed.

OR a. Click Devices .

The Devices tab is displayed.

Rack management 41

b. Click PLUGIN GROUPS > Physical Hierarchy , expand until rack level and right-click the group, and select Manage

Rack option.

The Manage Rack page is displayed.

2. To Associate the PDUs to a rack, perform one of the following steps:

● Click the Associated Devices tab and then click Associate to Rack .

The Select Device(s) wizard is displayed.

NOTE: On this page only the PDUs are displayed for selection.

OR

● Click the Add to Rack Slot option.

The Select Device(s) wizard is displayed.

NOTE: On this page all the devices added to Power Manager is displayed.

3. Optional: To filter and view the data: a. Click Advanced Filters .

The following filters are displayed:

● Health State

● Power State

● Connection State

● Name

● Identifier

● Model

● Type

● Managed State

4. Optional: To clear the filters, click Clear All Filters .

5. In the Select Device(s) section, select the devices and click Next .

6. In Add device(s) to rack slots section, click Finish .

The PDU devices are associated with the rack and are listed in the Associated Devices tab.

42 Rack management

10

Manage data center during power reduction

The Emergency Power Reduction (EPR) feature helps reduce power consumption of devices immediately during a power emergency. For example, if there is a power failure occurs and your devices are running on a UPS, you can apply EPR to reduce the power consumption of your managed devices.

EPR also helps in preventing device damage due to overheating in an event of cooling infrastructure failure. Use temperaturetriggered policies for enabling EPR on a group of devices when its average inlet temperature crosses a defined threshold value.

NOTE: Applying EPR on the devices throttles down the power to an extremely low level, impacting performance, or shuts down the devices completely. All devices on which an EPR is applied are affected. Use this feature only in an emergency situation.

Following are the EPR options available for servers, chassis, and groups:

● Throttle —set to minimal power consumption state.

NOTE: Only the Throttle option is supported for a chassis.

● Shut down —shut down the server

After applying EPR on devices and groups, they are marked as EPR Enabled (Throttle) or EPR Enabled (Shut down) on the

Power Manager Devices tab. The summary of devices and groups on which EPR is applied is displayed on the Emergency

Power Reduction tab in Power Manager .

Topics:

Enable Emergency Power Reduction

View active Emergency Power Reduction

Disable Emergency Power Reduction

Enable Emergency Power Reduction

During a power shortage, enable the Emergency Power Reduction (EPR) on devices so that they run on minimal power.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can enable EPR on a device or group that is defined in Device Manager DM1 user scope. And, only the Device Manager DM1 user or the Administrator can disable the EPR, if it is applied manually.

When Device Manager users have common groups or devices in their scope, and Device Manager DM1 user applies EPR on any of these groups or devices:

● Other Device Manager users, administrators, and viewers can see the red color banner. However, the active EPR is listed on

Emergency Power Reduction and Policies and EPR tabs only for Device Manager DM1 user and not for any other Device

Manager users since it is not a shared resource.

● If temperature-triggered EPR is applied on a group or device, due to a temperature-triggered policy created by Device

Manager DM1 user, then all the other Device Manager users can see the red color banner with the source of EPR.

NOTE: Temperature-triggered EPR cannot be activated manually. When a temperature-triggered policy is active and the group temperature is equal to or exceeds the threshold value, Power Manager automatically applies the EPR.

To enable EPR, perform the following steps:

Steps

1. From OpenManage Enterprise, perform one of the following steps:

Manage data center during power reduction 43

● For a device: a. Click the Devices tab.

All the devices that are discovered in OpenManage Enterprise are displayed.

b. From the list of devices, click a device name.

The details of the device are displayed on the Overview page.

c. To view Power Manager-related information, click the Power Management and Monitoring tab.

● For a static group: a. Click Devices > Static Groups > Group name .

All the devices that are part of the static group are displayed.

b. To view Power Manager-related information, click Group Details .

● For a physical group, perform one of the following steps: a. Click Devices > Physical Hierarchy > Group name .

All the devices that are part of the physical group are displayed.

b. To view Power Manager-related information, click Group Details .

OR a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View tab is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

○ Group Name

○ Health State

○ Power State

○ Connection State

○ Type

Select the categories of your choice and view the filtered data.

b. Click the device name or IP address.

2. To enable EPR, click the Policies and EPR tab, and then click Apply EPR .

In the confirmation screen, select one of the options and click Apply EPR .

● Throttle —All selected devices and groups are allowed to consume an extremely low level of power. This setting affects performance.

NOTE: The throttle option is supported for servers with iDRAC DC or iDRAC Enterprise licenses and chassis.

● Shut down —All selected devices or devices part of the selected group are shut down gracefully.

NOTE: If a group consists of servers and chassis, and you select the Shut down option, then only the servers in the group are shut down. The shut-down option applies only to servers.

3. Click Yes on the confirmation screen.

EPR is enabled on the selected device or group. A red color bar indicator is displayed on the Policies and EPR tab along with the type of EPR option applied.

View active Emergency Power Reduction

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

If you are logging in as a Device Manager DM1 user, you can view only the EPRs applied by Device Manager DM1 user on the assigned devices and groups.

When Device Manager users have common groups or devices in their scope, and Device Manager DM1 user applies EPR on any of these groups or devices:

● Other Device Manager users, administrators, and viewers can see the red color banner. However, the active EPR is listed on

Emergency Power Reduction and Policies and EPR tabs only for Device Manager DM1 user and not for any other Device

Manager users since it is not a shared resource.

44 Manage data center during power reduction

● If temperature-triggered EPR is applied on a group or device, due to a temperature-triggered policy created by Device

Manager DM1 user, then all the other Device Manager users can see the red color banner with the source of EPR.

To view the list of devices and groups to which Emergency Power Reduction (EPR) is applied, perform the following:

Steps

From OpenManage Enterprise, perform any one of the following:

● To view, an EPR applied on a device or a group, click the Devices tab, click the device name, Power Management and

Monitoring tab, and then click Policies and EPR .

● To view EPRs applied on all devices and groups in Power Manager: a. Click Plugins > Power Management > Emergency Power Reduction .

The Emergency Power Reduction tab is displayed.

The following fields are displayed:

● ASSIGNED TO —Device name or service tag to which the EPR is applied.

● ENTITY TYPE —Type of device. The supported entity types are, devices, and groups.

● EPR TYPE —Type of EPR applied. The supported EPR types are Throttle and Shut down .

● EPR SOURCE —Source of EPR trigger. You can apply an EPR manually or automatically.

● CREATED ON —Time the EPR was applied.

b. To filter and view the data, click Advanced Filters .

You can filter your data using the following components:

● Assigned To —Filters EPRs based on the device name or service tag.

● EPR Source —Filters the EPR source. The supported filters are, All , Manual , and Temperature-triggered .

c. To sort any column alphabetically, click a column name so that an arrow is displayed with the column name.

Disable Emergency Power Reduction

To restore the devices or groups to their normal state, disable the Emergency Power Reduction (EPR).

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can disable only the EPRs that Device Manager DM1 user has applied, and on the devices and groups that Device Manager DM1 user has access to.

NOTE: An EPR activated due to a temperature-triggered event cannot be disabled manually. After the temperature reduces to the normal value, Power Manager automatically removes the EPR.

To disable a manually applied EPR, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Emergency Power Reduction .

2. Select the devices or groups, and click Disable .

On the confirmation page, click Yes .

EPR is disabled successfully.

Manage data center during power reduction 45

11

Quick access to Power Manager data

To quickly view Power Manager data, navigate to the OpenManage Enterprise or Power Manager dashboards.

● To quickly view power and thermal history of your favorite groups, add them to OpenManage Enterprise dashboard. For more information, see

Viewing power and thermal history of Power Manager groups

.

● To view top five devices or groups that consume maximum energy, see the Top Energy Consumer graph on the

OpenManage Enterprise dashboard.

● To view a ratio of number of devices that are added to OpenManage Enterprise and are compatible with Power Manager to total devices that are managed by Power Manager, see Power Manager Devices Statistics graph on the OpenManage

Enterprise dashboard.

To view top 10 offenders of power and temperature, see Viewing top 10 offenders

.

Topics:

View power and thermal history of Power Manager groups

View top five energy consumers

View ratio of devices discovered in OpenManage Enterprise to devices added in Power Manager

View top ten power offenders

View top ten temperature offenders

View top ten underutilized racks for power and space

View power and space headroom

View power and thermal history of Power Manager groups

About this task

Quickly access Power Manager-specific data on the OpenManage Enterprise dashboard.

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view the power and thermal history graphs of devices and groups that are assigned to a Device Manager DM1 user. Only the groups in Device Manager DM1 user scope, and that consume maximum power and generate maximum temperature are listed.

Steps

1. Launch OpenManage Enterprise, click Home and go to the Power Manager section.

2. To view the power or thermal history of a group, click the Power History or Thermal History tab.

The graph is displayed.

3. Optional: To change the duration, select an option from the Duration drop-down menu.

4. Search for a group using the Group search box.

5. Optional: To refresh the data, click the refresh option.

View top five energy consumers

About this task

View the devices consuming most of the energy in the Power Manager section of the OpenManage Enterprise dashboard.

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

46 Quick access to Power Manager data

For example, if you are logging in as a Device Manager user, only the top five devices consuming the most energy from the groups that are assigned to Device Manager DM1 user are displayed.

Steps

1. Launch OpenManage Enterprise, click Home , and then go to the Power Manager section.

2. To view the top five energy consumers, click the Top Energy Consumers tab.

3. View data regarding servers, chassis, and groups using the Filter drop-down menu.

View ratio of devices discovered in OpenManage

Enterprise to devices added in Power Manager

About this task

View the ratio of total devices that are discovered in OpenManage Enterprise and that are compatible with Power Manager to the total number of devices that are monitored through Power Manager.

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view a comparison between total devices that are assigned to Device Manager DM1 user, that are capable with Power Manager for monitoring, to the number of devices added to

Power Manager for monitoring within Device Manager DM1 scope of devices.

Steps

1. Launch OpenManage Enterprise, click Home , and go to the Power Manager section.

2. To view the ratio, click the Devices Statistics tab.

View top ten power offenders

Prerequisites

Ensure that you have configured the power and temperature thresholds in the Alert Thresholds tab under the Power

Management and Monitoring tab for devices, or under Group Details for groups.

About this task

To view a list of devices and groups that have violated the defined threshold values of power, run the in-built for Power

Manager: Metric Thresholds Report for Devices and Power Manager: Metric Thresholds Report for Groups . The total violation count for power is the sum of upper warning, and upper critical violation counts. The total violation count for temperature is the sum of upper warning, upper critical, lower warning, and lower critical violation counts.

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

If you are logging in as a Device Manager DM1 user, the top 10 devices that are assigned to the Device Manager DM1 user and that have violated the defined threshold values for the maximum number of times are displayed.

Steps

1. Launch OpenManage Enterprise and click Plugins > Power Management > Overview tab.

The Overview tab is displayed.

2. View the Top 10 Power Offenders section.

Device information that is provided by default includes details such as device name, service tag, number of times the device has violated the defined power threshold, and the nature of violations that are based on the alert threshold values defined.

3. To view the groups that have violated the power threshold, select the Groups option from the Entity Type drop-down menu.

Device information that is provided by default includes details such as group name, number of times the group has violated the defined power threshold, and nature of violations that are based on the alert threshold values defined.

4. To view devices or groups in a particular violation state, select an option from the State drop-down menu.

Quick access to Power Manager data 47

5. Optional: To refresh the data, click the refresh option.

View top ten temperature offenders

Prerequisites

Ensure that you have configured the power and temperature thresholds in the Alert Thresholds tab under the Power

Management and Monitoring tab for devices, or under Group Details for groups.

About this task

To view a list of devices and groups that have violated the defined threshold values of power, run the in-built for Power

Manager: Metric Thresholds Report for Devices and Power Manager: Metric Thresholds Report for Groups . The total violation count for power is the sum of upper warning, and upper critical violation counts. The total violation count for temperature is the sum of upper warning, upper critical, lower warning, and lower critical violation counts.

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

If you are logging in as a Device Manager DM1 user, all the devices that have violated the temperature maximum number of times within Device Manager DM1 user's scope are displayed.

Steps

1. Launch OpenManage Enterprise and click Plugins > Power Management > Overview tab.

The Overview tab is displayed.

2. To view the devices that have violated the temperature threshold go to the Top 10 Temperature Offenders section.

Device information that is provided by default includes information such as device name, service tag, the number of times the device has violated the defined temperature threshold, and the nature of violations that are based on the alert threshold values defined.

3. To view the groups that have violated the temperature threshold, select the Groups option from the Entity Type dropdown menu.

Device information that is provided by default includes information such as group name, service tag, number of times the group has violated the defined temperature threshold, and nature of violations that are based on the alert threshold values defined.

4. To view devices or groups in a particular violation state, select an option from the State drop-down menu.

5. Optional: To refresh the data, click the refresh option.

View top ten underutilized racks for power and space

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

If you are logging in as a Device Manager DM1 user, the top 10 underutilized racks in the physical groups that are assigned to

Device Manager DM1 user are displayed.

To view the top 10 underutilized racks, perform the following steps:

Steps

1. Launch OpenManage Enterprise and click Plugins > Power Management > Overview tab.

The Overview tab is displayed.

2. To view the racks for unutilized power, go to the Top 10 Underutilized Racks (Power) graph.

By default, the Actual view is displayed.

To change the scale to the percentage, click the View drop-down menu and select the Percentage option.

3. To view the top 10 racks for unutilized space, go to the Top 10 Underutilized Racks (Space) graph.

By default, the Actual view is displayed.

48 Quick access to Power Manager data

To change the scale to the percentage, click the View drop-down menu and select the Percentage option.

4. To view the information in tabular format, click the tabular image.

The respective table is displayed.

5. To refresh the data, click the Refresh option.

View power and space headroom

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

If you are logging in as a Device Manager DM1 user, the power and space headroom data for the physical groups that are assigned only to Device Manager DM1 user is displayed.

To view the consumption of power in a group, perform the following steps:

Steps

1. Launch OpenManage Enterprise and click Plugins > Power Management > Overview tab.

The Overview tab is displayed.

2. Go to the Headroom section.

The power headroom and the space headroom graphs are displayed.

3. To change the group name, provide the group name in the Physical Hierarchy Group field and press the Enter key.

Details of power and space headroom are displayed.

4. Optional: To refresh the data, click the refresh option.

Quick access to Power Manager data 49

12

Maintain Power Manager

Manage the plugin and the devices and groups added to Power Manager along with managing the alerts and thresholds.

Topics:

Manage Power Manager plugin

Manage individual devices and static groups

Manage physical groups

Maintain alert thresholds

Maintain policies

Managing unmonitored devices

Manage PDU devices

Uninstalling Power Manager

Manage Power Manager plugin

Disable or enable the Power Manager plugin to monitor your devices for power and temperature.

Disable Power Manager

Disables all the functionality of Power Manager on OpenManage Enterprise. The REST APIs specific to Power Manager are also disabled.

Prerequisites

Ensure that the following prerequisites are met:

● The Emergency Power Reduction (EPR) is not enabled on the device. View the EPR status of all devices and groups on the

Emergency Power Reduction page.

● There are no active policies.

Information about the number of users using OpenManage Enterprise and details about the jobs running are displayed.

About this task

NOTE: Disabling a plugin in OpenManage Enterprise restarts the appliance services.

Steps

1. Launch OpenManage Enterprise, and click Application Settings > Console and Plugins .

The Console and Plugins tab is displayed.

2. In the Power Manager section, click the Disable option.

The Disable Plugin page is displayed.

3. Click Disable Plugin .

The Confirmation page is displayed.

4. On the Confirmation page, select the I agree that I have captured a snapshot of the OpenManage Enterprise appliance prior to performing a plugin action.

option, and then click Confirm Disable .

Information about the number of users using OpenManage Enterprise and details about the jobs running are displayed.

Results

After disabling Power Manager, you cannot see any information or pages that are related to Power Manager in OpenManage

Enterprise.

50 Maintain Power Manager

Enable Power Manager

All features of Power Manager are enabled in OpenManage Enterprise. The REST APIs specific to Power Manager are also enabled in OpenManage Enterprise .

About this task

NOTE: Enabling a plugin in OpenManage Enterprise restarts the appliance services.

Steps

1. Launch OpenManage Enterprise, and click Application Settings > Console and Plugins .

The Console and Plugins tab is displayed.

2. In the Power Manager section, click the Enable option.

The Enable page is displayed.

3. Click Enable Plugin .

The Confirmation page is displayed.

4. In the Confirmation page, select I agree that I have captured a snapshot of the OpenManage Enterprise appliance prior to performing a plugin action.

, and then click Confirm Enable .

Information about the number of users using OpenManage Enterprise and details about the jobs running are displayed.

Manage individual devices and static groups

Remove existing individual devices or static groups in the Power Manager plugin.

View devices and groups added to Power Manager

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view only the groups that are assigned to the Device

Manager DM1 user.

To view devices or groups that are added to Power Manager, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Power Manager Devices .

The Power Manager Devices tab is displayed.

2. To refresh the list of devices and groups that are added, click Refresh the list for Power Manager Capabilities .

3. To view a device or a group that is added to Power Manager, perform one of the following:

● To view a static group, click the Static Groups tab.

● To view a physical group, click the Physical Groups tab.

NOTE: The location of the physical group is displayed based on the hierarchy that is selected for this particular group at the time of creation.

● To view a device, click the Individual Devices tab.

● To view all the devices added to Power Manager as individual devices and as a part of groups, click the All Monitored

Devices tab.

4. Optional: To filter and view the data on any of the tabs: a. Click a tab.

b. Click Advanced Filters .

c. Select a filter category.

The following filters are displayed for the Static Groups and Physical Groups tabs:

● Group Name

Maintain Power Manager 51

The following filters are displayed for the Individual Devices tab:

● Health State

● Power State

● Connection State

● Name

● Identifier

● Model

● Type

● Managed State

The following filters are displayed for the All Monitored Devices tab:

● Health State

● Power State

● Connection State

● Name

● Identifier

● Model

● Type

● Managed State

● Part of Group

For information about each filter, see the Appendix

.

5. Optional: To clear the filters, click Clear All Filters .

6. Optional: To sort any column alphabetically, click the column name so that an arrow is displayed with the column name.

Remove devices

To stop monitoring the devices, remove them from Power Manager.

Prerequisites

Ensure that the following prerequisite is met:

● The Emergency Power Reduction (EPR) is not enabled on the device.

About this task

NOTE: If a device is removed in OpenManage Enterprise , then that device is automatically removed from Power

Manager.

NOTE: When a device is added individually and as part of a group to Power Manager, ensure that all the instances of the device are removed from Power Manager to stop monitoring the devices.

For example, if you are logging in as a Device Manager user, you can delete the devices from the physical groups that are assigned to you from the Indiviual Devices tab. However, after removing the device from Power Manager, you cannot re-add the device to Power Manager when logged in as a Device Manager user.

To remove a device, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Power Manager Devices .

The Power Manager Devices tab is displayed.

2. Click the Individual Devices tab.

The Individual Devices tab is displayed.

3. Select the devices that you want to remove and click Remove Device(s).

The Remove Device confirmation window is displayed.

4. To confirm removal, click Remove .

The devices are removed from Power Manager.

52 Maintain Power Manager

Remove groups

To stop monitoring the groups, remove them from Power Manager.

Prerequisites

Ensure that the following prerequisite is met:

● The Emergency Power Reduction (EPR) option is not enabled on the specific devices that are part of the group.

About this task

To remove a group, perform the following steps:

NOTE: If a group or a specific device in a group is removed from OpenManage Enterprise , then the changes are automatically reflected in Power Manager.

NOTE: After applying a policy to a group, if you delete the group, the policy is also removed from Power Manager.

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Power Manager Devices .

The Power Manager Devices tab is displayed.

2. Click the Static Groups tab.

The Static Groups tab is displayed.

3. Select the groups and click Remove Group(s) .

The Remove Group confirmation window is displayed.

4. To confirm the removal, click Remove .

The groups are removed from Power Manager.

Manage physical groups

Edit or rearrange devices in existing physical groups in the Power Manager plugin.

View physical groups and the hierarchies

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view only the devices and groups that are assigned to a Device Manager DM1 user.

Use this page to view the physical groups created in Power Manager.

NOTE: To view a complete list of devices in a physical group (including the Unmonitored Devices) click the Rack View tab.

To view the physical groups, perform the following steps:

Steps

Launch OpenManage Enterprise and perform one of the following steps: a. On the Devices page, in the left pane, expand the PLUGIN GROUPS section.

b. Expand the Physical Hierarchy group to view all the physical groups created.

OR a. Click Plugins > Power Management > Power Manager Devices .

The Power Manager Devices tab is displayed.

b. Click Physical Groups .

Maintain Power Manager 53

All the physical groups that are created in Power Manager are displayed with their name, location, total devices in the group, and information about when they were added to Power Manager.

NOTE: The location of the physical group is displayed based on the hierarchy that is selected for this particular group at the time of creation.

View devices added in rack

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, If you are logging in as a Device Manager DM1 user, you can view only the devices and groups that are assigned to a Device Manager DM1 user.

To view the devices added in a rack of a physical group, perform the following steps:

Steps

1. Launch OpenManage Enterprise and perform one of the following steps: a. On the Devices page, in the left pane, expand the PLUGIN GROUPS section.

b. To view the devices, expand the Physical Hierarchy group until a rack level and right-click and select the Manage

Rack option.

The Manage Rack page is displayed.

Or a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View page is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

● Group Name

● Health State

● Power State

● Connection State

● Type

Select the categories of your choice and view the filtered data.

b. Click the rack name.

The Manage Rack page is displayed.

2. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View page is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

● Group Name

● Health State

● Power State

● Connection State

● Type

Select the categories of your choice and view the filtered data.

3. View the devices in the rack by navigating on the Manage Rack page.

All the devices added to the rack are displayed.

4. Optional: View the Space Capacity field at the upper right side of the page to know the amount of space consumed in the rack.

54 Maintain Power Manager

View racks of physical groups

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view only the devices from groups that are assigned to a Device Manager DM1 user in rack view.

To view the devices in a rack, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View page is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

● Group Name

● Health State

● Power State

● Connection State

● Type

Select the categories of your choice and view the filtered data.

2. To view the Power Management and Monitoring details of a device that is monitored by Power Manager, click the device name.

NOTE: Some devices that are part of a physical group do not have a link because, the device is not Power Manager capable.

The Power Management and Monitoring details for the device are displayed.

Edit physical groups

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can only view the groups and devices in the groups that are assigned to Device Manager DM1 user. You cannot perform any management tasks on the physical groups such as editing, moving devices to different racks and so on.

To edit a physical group, perform the followings steps:

NOTE: You cannot edit the Group Hierarchy after creating a physical group.

Steps

1. Launch OpenManage Enterprise.

2. On the Devices page, in the left pane, expand the PLUGIN GROUPS section.

3. To edit a physical group, do one of the following:

● In the Physical Hierarchy section, expand the group, right-click the group, and then select Edit Group .

The Edit Physical Group page is displayed.

NOTE: The power capacity for a group is the sum of power consumption of the devices within the group, and a suggestion for the total group power capacity is displayed below the Power Capacity field.

● To edit the power or space capacity of a physical group, in the Physical Hierarchy section, click the options, and then click Attributes .

The Group Attributes page is displayed.

Maintain Power Manager 55

4. Make the changes and click Finish or Save .

Delete physical group

Delete physical groups that are no longer valid.

Prerequisites

Ensure that the Emergency Power Reduction (EPR) option is disabled on the physical group.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can only view the groups and devices in the groups that are assigned to Device Manager DM1 user. You cannot perform any management tasks on the physical groups such as editing, moving devices to different racks and so on.

To delete a physical group, perform the following steps:

NOTE: After applying a policy to a group, if you delete the group, the policy is also removed from Power Manager.

Steps

1. Launch OpenManage Enterprise.

2. On the Devices page, in the left pane, expand the PLUGIN GROUPS section.

3. In the Physical Hierarchy section, go to the group you want to delete, right-click the group, and then click Delete Group .

4. In the confirmation screen, click Yes .

Results

The group is deleted.

Rearrange rack slot of devices

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can only view the groups and devices in the groups that are assigned to Device Manager DM1 user. You cannot perform any management tasks on the physical groups such as editing, moving devices to different racks and so on.

To rearrange the rack slot of the devices in a rack, perform the following steps:

Steps

1. Launch OpenManage Enterprise and perform one of the following steps: a. On the Devices page, in the left pane, expand the PLUGIN GROUPS section.

b. To view the devices, expand the Physical Hierarchy group until a rack level and right-click and select the Manage

Rack option.

The Manage Rack page is displayed.

Or a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View page is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

● Group Name

● Health State

56 Maintain Power Manager

● Power State

● Connection State

● Type

Select the categories of your choice and view the filtered data.

b. Click the rack name.

The Manage Rack page is displayed.

2. Locate the device that you want to move using the vertical scroll bar of the rack and select the device.

3. Click Rearrange Rack .

The Update Rack Slots page is displayed.

4. To change the slot for a device, click the drop-down menu and select an empty slot.

5. Click Finish .

The device slot is updated.

Move device to different rack

Based on the changes in the data center, you can change the location of the device in a physical group.

Prerequisites

Ensure that the Emergency Power Reduction (EPR) is not enabled on the target rack.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can only view the groups and devices in the groups that are assigned to Device Manager DM1 user. You cannot perform any management tasks on the physical groups such as editing, moving devices to different racks and so on.

To move a device to another rack within the same physical group or to another physical group, perform the following steps:

Steps

1. Launch OpenManage Enterprise and perform one of the following steps: a. On the Devices page, in the left pane, expand the PLUGIN GROUPS section.

b. To view the devices, expand the Physical Hierarchy group until a rack level and right-click and select the Manage

Rack option.

The Manage Rack page is displayed.

Or a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View page is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

● Group Name

● Health State

● Power State

● Connection State

● Type

Select the categories of your choice and view the filtered data.

b. Click the rack name.

The Manage Rack page is displayed.

2. To move the device to another rack, click Move Device to Another Rack .

The Select Group page is displayed.

3. Optional: To filter and view the data, click Advanced Filters .

Search the group using the Group Name field.

To clear the filters, click Clear All Filters .

Maintain Power Manager 57

4. Select the rack and click Move .

The device is moved to the new rack.

Remove device from rack

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager user, you can delete the devices from the physical groups that are assigned to you from the Indiviual Devices tab. However, after removing the device from Power Manager, you cannot re-add the device to Power Manager when logged in as a Device Manager user.

To remove a device from the rack, perform the following steps:

Steps

1. Launch OpenManage Enterprise and perform one of the following steps: a. On the Devices page, in the left pane, expand the PLUGIN GROUPS section.

b. To view the devices, expand the Physical Hierarchy group until a rack level and right-click and select the Manage

Rack option.

The Manage Rack page is displayed.

Or a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View page is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

● Group Name

● Health State

● Power State

● Connection State

● Type

Select the categories of your choice and view the filtered data.

b. Click the rack name.

The Manage Rack page is displayed.

2. Select the devices and click Remove Device(s) From Rack .

3. In the confirmation page, click Yes .

The devices are removed from the rack.

Maintain alert thresholds

View alert thresholds

View the status of the device or group that is based on the configured alert thresholds.

Prerequisites

Ensure that you have added devices or groups to Power Manager.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

58 Maintain Power Manager

For example, if you are logging in as a Device Manager DM1 user, you can view and manage all the alert thresholds that are configured by any Device Manager user or Administrator on the groups and devices that are in Device Manager DM1 user's scope.

To view the alert thresholds graphs for power and temperature:

Steps

1. From OpenManage Enterprise, perform one of the following steps:

● For a device: a. Click the Devices tab.

All the devices that are discovered in OpenManage Enterprise are displayed.

b. From the list of devices, click a device name.

The details of the device are displayed on the Overview page.

c. To view Power Manager-related information, click the Power Management and Monitoring tab.

● For a static group: a. Click Devices > Static Groups > Group name .

All the devices that are part of the static group are displayed.

b. To view Power Manager-related information, click Group Details .

● For a physical group, perform one of the following steps: a. Click Devices > Physical Hierarchy > Group name .

All the devices that are part of the physical group are displayed.

b. To view Power Manager-related information, click Group Details .

OR a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View tab is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

○ Group Name

○ Health State

○ Power State

○ Connection State

○ Type

Select the categories of your choice and view the filtered data.

b. Click the device name or IP address.

2. View the power and temperature status on the Alert Thresholds tab.

The Collected At field displays the last collection time.

The pointer on the scale gives the average power and thermal data.

Power Manager displays the minimum and maximum power and temperature values of the device and the previous readings that were collected. The scale is disabled if the thresholds are not set or if the threshold values are cleared off. The upper and lower warning and critical values are displayed only if the threshold values are set. To view more information about any violations, see the Alert Log on the Alerts page and the Audit Logs on the Monitor page.

Edit alert thresholds

Update alert thresholds based on changes to device utilization or updates in group membership.

Prerequisites

Ensure that you have added devices or groups to Power Manager.

Maintain Power Manager 59

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view and manage all the alert thresholds that are configured by any Device Manager user or Administrator on the groups and devices that are in Device Manager DM1 user's scope.

To edit the threshold values for a device or a group, perform the following steps:

Steps

1. From OpenManage Enterprise, perform one of the following steps:

● For a device: a. Click the Devices tab.

All the devices that are discovered in OpenManage Enterprise are displayed.

b. From the list of devices, click a device name.

The details of the device are displayed on the Overview page.

c. To view Power Manager-related information, click the Power Management and Monitoring tab.

● For a static group: a. Click Devices > Static Groups > Group name .

All the devices that are part of the static group are displayed.

b. To view Power Manager-related information, click Group Details .

● For a physical group, perform one of the following steps: a. Click Devices > Physical Hierarchy > Group name .

All the devices that are part of the physical group are displayed.

b. To view Power Manager-related information, click Group Details .

OR a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View tab is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

○ Group Name

○ Health State

○ Power State

○ Connection State

○ Type

Select the categories of your choice and view the filtered data.

b. Click the device name or IP address.

2. On the Alert Thresholds tab, click Edit .

The Edit Alert Thresholds page is displayed.

3. Provide the values and click Apply .

Threshold values are updated successfully.

Delete alert thresholds

To remove the thresholds that are configured on devices or groups, clear all the thresholds.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

60 Maintain Power Manager

For example, if you are logging in as a Device Manager DM1 user, you can create and manage alert thresholds that are created by any other Device Manager user only for the devices in Device Manager DM1 user scope.

To delete alert thresholds, perform the following steps:

Steps

1. From OpenManage Enterprise, perform one of the following steps:

● For a device: a. Click the Devices tab.

All the devices that are discovered in OpenManage Enterprise are displayed.

b. From the list of devices, click a device name.

The details of the device are displayed on the Overview page.

c. To view Power Manager-related information, click the Power Management and Monitoring tab.

● For a static group: a. Click Devices > Static Groups > Group name .

All the devices that are part of the static group are displayed.

b. To view Power Manager-related information, click Group Details .

● For a physical group, perform one of the following steps: a. Click Devices > Physical Hierarchy > Group name .

All the devices that are part of the physical group are displayed.

b. To view Power Manager-related information, click Group Details .

OR a. Launch OpenManage Enterprise, and then click Plugins > Power Management > Rack View .

The Rack View tab is displayed.

Optional: To filter and view the data, expand the Advanced Filters option. Following is a list of categories available:

○ Group Name

○ Health State

○ Power State

○ Connection State

○ Type

Select the categories of your choice and view the filtered data.

b. Click the device name or IP address.

2. On the Alert Thresholds tab, click Edit .

The Edit Alert Thresholds page is displayed.

3. To remove all the thresholds, clear all the existing threshold values, and click Apply .

Maintain policies

View policy

View all the policies that are created for devices and groups in Power Manager.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view only the policies that are created by Device

Manager DM1 user and apply these policies only on the groups in Device Manager DM1 user scope. However, the Administrator has access to all the policies created by all the Device Manager users.

To view a policy, perform the following steps:

Maintain Power Manager 61

Steps

From OpenManage Enterprise, perform any one of the following:

● To view all the policies created in Power Manager:

Click Plugins > Power Management > Policies .

The Policies tab is displayed.

Select your category of filters, and view the data. Following is a list of categories available:

○ State —Filters the policies based on the state of the policy. The supported filters are All , Enabled , Disabled .

○ Name —Filters the policies based on the name of the policy.

○ Description —Filters the policies based on the description of the policy.

○ Type —Filters the policies based on the type of policy. The supported filters are, All , Static , and Temperature-

Triggered .

○ Assigned To —Filters policies based on device or group it is assigned to.

To filter and view the data, click Advanced Filters .

To clear the filters, click Clear All filters .

To sort any column alphabetically, click a column name so that an arrow is displayed with the column name.

● To view all the policies created for a device—click Devices > Power Management and Monitoring > Policies

All the policies applied to the device are displayed with the details.

● To view all the policies created for a group—click Devices , click a custom group with static membership, click Group

Details , and then click Policies .

The policies applied to the group are displayed with the details.

Edit policy

Update a policy based on the changes in power consumption history or average inlet temperature that is generated by the devices or groups.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can edit only the policies that are created by a Device

Manager DM1 user.

When there are changes to group membership and the group has an active policy, then Power Manager notifies you to reevaluate the policy associated with the group.

NOTE: After you create a policy for a device, you cannot apply the policy to a group. Similarly, after creating a policy for a group, you cannot apply the policy to a device.

NOTE: For a temperature-triggered policy, if the temperature threshold value is increased after the EPR is applied, then

Power Manager automatically removes the EPR if the updated temperature threshold value is greater than the average temperature of the group.

To edit a policy, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Policies .

The Policies tab is displayed.

2. Select a policy and click Edit .

The power policy wizard is displayed.

For more information about each field in the wizard, see

Create power or temperature-triggered policy

.

3. To save your changes, click Finish .

The changes are saved successfully.

62 Maintain Power Manager

Disable policy

To remove power consumption or temperature policy limits, disable the relevant policy.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can disable only the policies that are created by a Device

Manager DM1 user.

To disable a policy, perform one of the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Policies .

The Policies tab is displayed.

2. Perform one of the following methods: a. Select the policy that you want to disable, and click Disable .

b. In the confirmation window, click Yes .

OR a. Select the policy that you want to disable, and click Edit .

The Create Policy wizard is displayed.

b. In the General section, clear the Enable check-box and click Next until you reach the Summary section, and then click

Finish .

The policy is disabled successfully.

Enable policy

On enabling a policy, the power or temperature cap is activated on the devices and groups.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can enable only the policies that are created by a Device

Manager DM1 user.

To enable a policy, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Policies .

The Policies tab is displayed.

2. Enable a policy using any one of the following methods:

● Select the policy that you want to enable, and click Enable .

● At the time of creation or when editing the policy, select the Enable option from Create Power Policy wizard.

3. In the confirmation window, click Yes .

The policy is enabled successfully, and a tick mark is displayed against the policy.

Maintain Power Manager 63

Delete policy

Delete policies that are no longer required.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can delete only the policies that are created by the Device

Manager DM1 user.

When an active policy is deleted, any power consumption restrictions or temperature thresholds that are applied by the policy are also deleted.

NOTE: If you delete an active temperature-triggered policy, the Emergency Power Reduction (EPR) is automatically removed from the group.

To delete a policy, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Policies .

The Policies tab is displayed.

2. Select a policy that you want to delete, and click Delete .

3. In the confirmation window, click Yes .

The policy is deleted successfully.

Managing unmonitored devices

View details of Unmonitored Devices

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view the unmonitored devices that are part of the group in your scope.

To view the details of the devices, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Power Manager Devices .

The Power Manager Devices tab is displayed.

2. Click UNMONITORED > Unmonitored Devices .

All the Unmonitored Devices details are listed on the Unmonitored Devices tab.

After adding the unmonitored devices in a physical group under a rack, the location and rack slot columns are populated for this device.

Edit Unmonitored Devices details

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can only view and cannot edit the unmonitored devices information that is part of the group in Device Manager DM1 user scope.

64 Maintain Power Manager

To edit the details of a device, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Power Manager Devices >

UNMONITORED > Unmonitored Devices .

The Unmonitored Devices tab is displayed.

2. Select a device and click Edit .

For information about the values of fields, see the Details for Unmonitored Devices table in

Adding Details of

Unmonitored Devices

.

3. Provide the details and click Finish .

Delete Unmonitored Devices

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can only view and cannot edit the unmonitored devices information that is part of the group in Device Manager DM1 user scope.

To delete an unmonitored device, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and then click Plugins > Power Management > Power Manager Devices >

UNMONITORED > Unmonitored Devices .

The Unmonitored Devices tab is displayed.

2. Select the devices and click Delete .

3. In the confirmation screen, click Yes .

Manage PDU devices

View PDUs associated to rack in Power Manager

View all the associated Power Distribution Units (PDUs) to a rack on a single page.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can only view all the PDU devices that are part of the group that is assigned to a Device Manager DM1 user.

Steps

1. Launch OpenManage Enterprise and perform one of the following steps:

● Click Plugins > Power Management > Rack View , and then right-click and select Manage Rack option.

The Manage Rack page is displayed.

OR a. Click Devices .

The Devices tab is displayed.

b. Click PLUGIN GROUPS > Physical Hierarchy , expand until rack level and right-click the group, and select Manage

Rack option.

The Manage Rack page is displayed.

Maintain Power Manager 65

2. To view the PDUs, click the Associated Devices tab.

All the PDUs that are associated with this rack are listed with all details.

View PDUs discovered in OpenManage Enterprise

View the details of a PDU after discovering it in OpenManage Enterprise.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can only view all the PDU devices that are part of the group that is assigned to a Device Manager DM1 user.

Steps

1. Launch OpenManage Enterprise and click Devices .

2. Expand ALL DEVICES , click PDU Devices and click a PDU device.

The Overview tab is displayed.

3. All the information about the PDU is displayed.

4. To view the IP address details, click the Hardware tab.

The Device Management Info tab is displayed with IP and MAC address along with the device URL and name.

● To view the NIC card details, click the NIC Information section.

The MAC, IPv4 address, and subnet mask information are displayed.

NOTE: Network Interface Controller (NIC) information is available only for PDUs by APC by Schneider Electric.

● To view PDU Outlet information such as outlet number, name, and power rating, click the PDU Outlet Information section.

For more information about the actions, you can perform on this page, see the Managing Devices section from

OpenManage Enterprise User's Guide.

Remove PDU devices

Remove faulty or old and decommissioned Power Distribution Unit (PDU) devices from a rack.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you cannot remove any PDU devices that are part of the group defined in Device Manager DM1 user scope.

Steps

1. Launch OpenManage Enterprise and perform one of the following steps:

● Click Plugins > Power Management > Rack View , and then right-click and select Manage Rack option.

The Manage Rack page is displayed.

OR a. Click Devices .

The Devices tab is displayed.

b. Click PLUGIN GROUPS > Physical Hierarchy , expand until rack level and right-click the group, and select Manage

Rack option.

The Manage Rack page is displayed.

2. To remove a PDU device, click the Associated Devices tab.

66 Maintain Power Manager

3. Select the device and click Remove Device(s) option.

4. In the confirmation screen, click Yes .

The PDU device is removed successfully from the rack.

Uninstalling Power Manager

Uninstall Power Manager and delete all the data that is collected by Power Manager.

Prerequisites

Ensure that the following prerequisites are met:

● The Emergency Power Reduction (EPR) is not enabled on the device. View the EPR status of all devices and groups on the

Emergency Power Reduction page.

● There are no active policies.

Information about the number of users using OpenManage Enterprise and details about the jobs running are displayed.

About this task

After uninstalling Power Manager, the iDRAC’s telemetry configuration is still enabled on the target servers.

For a list of telemetry services enabled by Power Manager, see the

supported protocols

.

To disable these configurations, perform one of the following actions:

● Create a server configuration template with a disabled telemetry streaming configuration in OpenManage Enterprise and deploy the template across all target devices.

● Manually disable the telemetry services in iDRAC on each device.

To uninstall Power Manager, perform the following steps:

Steps

1. Launch OpenManage Enterprise.

2. In Application Settings , click the Console and Extensions tab.

The Console and Extensions page is displayed.

3. In the Power Manager section, click the Uninstall option.

The Uninstall Extension page is displayed.

4. Click Uninstall Extension .

The Confirmation page is displayed.

5. In the Confirmation page, select I agree that I have captured a snapshot of the OpenManage Enterprise appliance prior to performing a plugin action.

, and then click Confirm Uninstall .

Information about the number of users using OpenManage Enterprise and details about the jobs running are displayed.

Results

After uninstalling Power Manager, you cannot see any information or pages that are related to Power Manager on OpenManage

Enterprise.

Maintain Power Manager 67

13

Alerts

An alert is helpful when monitoring thresholds and you want a notification about when the power of a device or a group exceeds the limits set on them or when there are changes to a group you are monitoring.

An alert is generated under the following circumstances:

● When the values cross the defined alert thresholds

● When the values for a device or group come back to normal state.

● When the policy cap of an active policy is violated.

● When there are changes to a group that has an active policy that is applied on it.

● When a policy is applied on a group and if new devices are added or devices are removed from the group.

You can view alerts by going to OpenManage Enterprise > Alerts > Alert Log :

For information about managing the alerts, see OpenManage Enterprise User's Guide .

Topics:

Create alert policy

Create alert policy

To receive Power Manager alerts, select the Power Manager-specific sub-categories while creating an alert policy.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can view the alert policies that are created by Device

Manager DM1 user and other Device Manager users, only on groups that are in your scope.

Steps

1. Launch OpenManage Enterprise, and click Alerts > Alert Policies .

The Alert Policies page is displayed.

2. On the Alert Policies page, click Create .

The Create Alert Policy wizard is displayed.

3. Provide a name and description for the policy.

To activate the policy after creation, the Enable option is selected by default.

4. In the Category section, expand the Application > System Health category and select the following sub-categories for

Power Manager alerts and click Next .

● Metrics —to receive alerts on alert threshold violations.

● Power Configuration —to receive alerts on policy cap violations.

5. In the Target section, select the required Power Manager devices or groups and click Next .

6. In the Date and Time section, provide a period for which the policy has to be active, select the days when the policy should be active, and click Next .

7. In the Severity section, select the severity level of the alert.

To select all the severity categories, select the All check-box.

8. In the Actions section, select one or more check-boxes to initiate the actions when the policy is run, and click Next .

9. In the Summary section, review the information and click Finish.

The alert policy is successfully created and listed in the Alert Policies section.

For more information about creating and managing the alerts, see OpenManage Enterprise User's Guide .

68 Alerts

14

Reports in Power Manager

Reports contain information about the specific devices or devices part of a group, jobs, alerts, and other elements of your data center. Power Manager supports inbuilt and user-defined reports. Download these reports to view the status of Power Manager devices and groups.

You can create customized reports with Power Manager details along with other device details from OpenManage Enterprise.

Definitions and attributes that are used for an integrated report cannot be edited or deleted, however, you can edit or delete the customized reports.

For information about running and emailing reports, or deleting custom reports, see OpenManage Enterprise User's Guide .

Topics:

Create custom report

View and download reports

Create custom report

Create a custom report to view a detailed report for specific devices or devices that are part of a group.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user, you can create custom reports only on the groups that are assigned to Device Manager DM1 user. Other Device Manager users cannot view the custom reports created on the same group since custom reports are not shared resources.

NOTE: If custom reports are created along with Power Manager categories, these categories are hidden when Power

Manager is disabled or deleted when Power Manager is uninstalled.

To create a custom report, perform the following steps:

Steps

1. Launch OpenManage Enterprise and click Monitor > Reports .

The Reports page is displayed.

2. Click Create .

The Report Definition page is displayed.

3. Provide a name and description, and then click Next .

4. In Category , select one of the following, and in the confirmation screen click Yes :

● To view data of Power Manager devices: a. Select Power Manager Devices .

b. On the confirmation page, click Yes .

c. In Device Group , select the required system groups or search for devices using the search box.

● To view Power Manager groups data: a. Select Power Manager Groups .

b. On the confirmation page, click Yes .

5. Optional: To create a query, click Edit in the Filter section. Create a query and click Finish . For more information about creating a query, see OpenManage Enterprise User's Guide .

6. In Column Selection , Ordering , and Sorting , expand the category and select the required fields using the checkbox to add them into the Column Order box.

Reports in Power Manager 69

The Device Metric Threshold and Device Power and Thermal Metrics columns are populated only for Power Manager devices.

The Group , Group Metric Threshold , Group Policy , Group Power and Thermal Metrics , Physical Group Power

Headroom , and Physical Group Space Headroom columns are populated only for Power Manager groups.

7. To sort by fields, use the Sort by drop-down menu and to sort the values in ascending and descending order, use the

Direction drop-down menu.

● If you have selected any column from the Metric Threshold collection, select the Metric Type of information you want to see.

● If you have selected any column from the Power and Thermal Metrics collection, select the Report Duration and

Aggregation Period to view the information.

NOTE: When creating a custom report, ensure that you select the Aggregation Period option as Daily if the Report

Duration is anything other than 1 Day .

8. Review the fields added, and then click Finish .

View and download reports

Run an integrated or custom report and view or download the report.

About this task

NOTE: If you are logging in as a Device Manager, only the device groups and devices that are in your scope are available for viewing and management.

For example, if you are logging in as a Device Manager DM1 user you can view all the integrated reports for the devices and groups assigned to Device Manager DM1 user. However, if Device Manager DM1 user has created any custom reports, only

Device Manager DM1 user and Administrator can view and access these reports.

NOTE: The reports are generated based on your selection for Report Duration and Aggregation Period in Power

Manager Settings page.

To view and download a report, perform the following steps:

Steps

1. Launch OpenManage Enterprise and click Monitor > Reports .

The Reports page is displayed.

The following integrated reports containing details of listed devices and groups are available for Power Manager related data through OpenManage Enterprise Reports tab:

● Power Manager: Metric Thresholds Report for Devices —Displays the metric and alert threshold details of all Power

Manager devices such as device name, device details, metric type, the threshold values set on the devices, and number of times the values have exceeded the defined thresholds.

● Power Manager: Metric Thresholds Report for Groups —Displays the alert threshold details of all the Power

Manager groups such as group name, metric type, threshold values set on groups, and number of times the values have exceeded the defined thresholds.

● Power Manager: Policies Report of Groups —Displays all the Power Manager policies details such as group name, policy name, policy type, whether the policy enabled, policy active, power cap, temperature threshold, and violations.

● Power Manager: Power and Thermal Report of Devices —Displays all the power and temperature details of Power

Manager devices such as device name, device details, power and temperature values, energy consumed, and what time the data was collected.

● Power Manager: Power and Thermal Report of Groups —Displays all the power and temperature details of Power

Manager groups such as the group name, power and temperature values of groups, energy consumed, and what time the data was collected.

● Power Manager: Power Headroom Report for Physical Groups —Displays the total power consumption of the group and remaining power that is assigned for the group.

NOTE: For the power headroom report, the power value that is considered for the calculation of stranded power is the most recent metric instead of the maximum power value for the selected report duration.

● Power Manager: Space Headroom Report for Physical Groups —Displays the total space that is consumed by the devices and provides information about the remaining rack space.

70 Reports in Power Manager

● Power Manager: Virtual Machine Performance Report —Displays the CPU count, CPU usage, power, and energy that is consumed by Virtual Machines that are monitored in Power Manager.

2. Locate and select the report that you want to view.

3. To run and view the report, click Run .

The report is displayed.

4. To download the report, click Download .

The Download Report page is displayed.

5. To download the report, select the required format, and then click Finish .

Power Manager supports downloading reports in the following formats:

● HTML

● CSV

● PDF

● XLS

The report is downloaded in the selected format.

Reports in Power Manager 71

15

Update Power Manager

About this task

To update Power Manager from OpenManage Enterprise, perform the following:

Steps

1. If you are not using the latest version of OpenManage Enterprise, upgrade OpenManage Enterprise to the latest compatible version of Power Manager.

For the list of compatible versions of Power Manager with OpenManage Enterprise, see

Versions of Power Manager compatible with OpenManage Enterprise

. For information about upgrading OpenManage Enterprise, see OpenManage

Enterprise User's Guide.

2. Configure the location of repository to check for updates. For more information, see Configuring OpenManage Enterprise for

Power Manager updates

.

3. Upgrade Power Manager. For more information, see

Upgrading Power Manager

.

Topics:

Configure OpenManage Enterprise for Power Manager updates

Upgrade Power Manager

Configure OpenManage Enterprise for Power

Manager updates

About this task

Check for Power Manager updates at downloads.dell.com

or an offline location . To configure OpenManage

Enterprise to view updates, perform the following:

Steps

1. Launch OpenManage Enterprise, and click Application Settings > Console and Plugins .

The Console and Plugins tab is displayed.

2. To configure updates, click Update Settings .

The Update Settings page is displayed.

3. In How to check for updates , select one of the following options:

● Automatic —automatically check for updates every week. This frequency cannot be changed.

● Manual —manually check for updates.

4. In Where to check for updates , select one of the following options and click Apply :

● Online —check for updates at downloads.dell.com

.

● Offline —check for updates at the specified offline source.

To use an internal network share as an offline update source, download the relevant files from downloads.dell.com

and save them on a NFS share preserving the same folder structure.

a. In Local Path , provide the location of the downloaded files. The format of a network share is: nfs://<IP

Address>/<Folder_Name> , http://<IP Address>/<Folder_Name> , or https://<IP Address>/

<Folder_Name> .

b. To verify the connection, click Test now .

72 Update Power Manager

Upgrade Power Manager

Prerequisites

Ensure that the version of Power Manager you plan to upgrade is compatible with the OpenManage Enterprise version. For

more information, see Versions of Power Manager compatible with OpenManage Enterprise

.

About this task

To update Power Manager, perform the following steps:

Steps

1. Launch OpenManage Enterprise, and click Application Settings > Console and Plugins .

The Console and Plugins tab is displayed.

2. In the Power Manager section, click Update Available .

The Update Plugin page is displayed.

3. To view the updates for this version, click the Release Notes link.

The support page is displayed.

4. To download the update, click Download Plugin .

The Enable plugin during update option is selected by default.

If you want to disable the plugin post upgrade, clear the Enable plugin during update option.

The plugin is downloaded, and the status of the download is displayed on a green color band.

5. To update Power Manager, click Update Plugin .

6. In the End User License Agreement window, review and click the Accept option.

7. In the Confirmation window, select the I agree that I have captured a snapshot of the OpenManage Enterprise appliance prior to performing a plugin action.

option, and then click Update .

Information about the number of users using OpenManage Enterprise and details about the jobs running in OpenManage

Enterprise is displayed.

After updating Power Manager the version is displayed on the Console and Plugins page in the Power Manager section.

To view the list of devices and groups that are Redfish capable, click Run Inventory in OpenManage Enterprise, and then click the Refresh Power Manager capabilities option on the Power Manager Devices page.

Update Power Manager 73

16

Frequently Asked Questions

Why am I not able to view the metrics?

Cause : After removing the required iDRAC or DC License, or the OpenManage Enterprise Advanced Feature license, the license-dependent features are not available on the User Interface (UI). Therefore, the metric is not available, and the values are not collected by Power Manager from the next inventory cycle.

Why do I see two entries with the same date in the graph when the time duration chosen for showing the graph is changed?

Cause : When viewing the Metrics and Monitoring History graphs for 3 months, 6 months, or 1 year, the data is autoconverted from the UTC time zone to your current time zone and displayed. Due to the time zone differences, there are two entries for the same day on the graphs. Therefore, the last entry is for the current day, and the last but one entry is for the previous day.

Why do I see slight variations in values of power and temperature in the Alert Thresholds section?

Cause : When the power and temperature values are provided in BTU/Hour and Fahrenheit, they are converted to Watt and

Celsius. When the values are displayed, they are reconverted and rounded off to the next highest numbers. Therefore, the values are slightly higher when displayed in BTU/Hour and Fahrenheit scale.

Why are there same number of power cap or threshold violations for all the entries in my report?

Cause : For a in-built or custom report which consists of a violation attribute along with a timestamp attribute, the violation count that is displayed for all the entries is always for the latest value.

Why do I see blank entries for total energy consumed in reports or metrics graphs?

Cause : The Total Energy Consumed field has no entry for servers and PowerEdge MX7000 devices due to the following reasons:

● The energy consumption value is not available until the second metric collection is taken.

● If you change the Data gathering interval to 60 minutes, then for a 60 minutes time period the Energy Consumption value cannot be calculated. This happens when data is collected for a day with hourly granularity for reports.

● If the power metric in iDRAC is reset during the interval that is chosen, and the latest reading has a lower value than the oldest reading.

74 Frequently Asked Questions

Why do I not see all metric types for different types of devices?

Cause : Different devices support different types of metrics.

Table 20. List of supported devices and metrics

Device Type

12 th generation of PowerEdge servers

13 th generation and 14 th generation of PowerEdge servers

PowerEdge M1000e, VRTX, FX2, and FX2s chassis

PowerEdge MX7000 chassis

Supported Metrics

● Maximum, minimum, and average power

● Maximum and average temperature

● System airflow

● Energy consumption

● Maximum, minimum, and average power

● Maximum and average temperature

● Maximum, minimum, and average CPU utilization

● Maximum, minimum, and average Input Output utilization

● Maximum, minimum, and average Memory Utilization

● System airflow

● Energy consumption

● Maximum, minimum, and average power

● Instant temperature

● Energy consumption

● Maximum and minimum power

● Maximum and minimum temperature

● Energy consumption

NOTE: Modular servers do not support System Airflow values.

Also, if all the criteria is met and still you are not able to view Power Manager data, ensure that the Server Power Monitoring feature is enabled on the device you are discovering. To view the discovery log of a device:

1. In OpenManage Enterprise, click Monitor > Jobs .

The Jobs page is displayed.

2. Search for the discovery type job for the device and select the job.

3. Click the View Details on the right side of the tab.

Details about the job are displayed.

In the Messages: section, check the status for Server Power Monitoring feature.

NOTE: If the Server Power Monitoring feature is disabled, then the device is not compatible with Power Manager .

Why do I see a failure of EPR in audit log but EPR is applied successfully for the device?

Cause : Applying EPR on the target device may fail due to the following reasons:

● Connectivity issues between the appliance and the target device.

● If the target device is part of Power Manager with an expired license.

Frequently Asked Questions 75

Why do I see a failure of EPR in audit log but EPR is applied successfully for the group?

Cause : When EPR option is applied for a group, and if the EPR option is applied successfully for at least one device in the group, the EPR banner is displayed at the group level. However, the EPR option may fail on other devices within the group due to connectivity issues or license expiry and so on. Therefore, use the EPR audit logs for successful and failure scenarios for all devices of the group.

Why are devices not listed for addition to Power Manager?

Cause : You cannot view certain devices in Power Manager because of the following reasons:

● If devices do not have OpenManage Enterprise Advanced license.

● If the devices are discovered in OpenManage Enterprise, and then Power Manager is installed, then the devices are not displayed in Power Manager until you Run Inventory on OpenManage Enterprise.

● Devices like switches, storage sleds, I/O modules are not supported in Power Manager.

● Servers that are discovered through the operating system(in-band) are not supported in Power Manager.

Why am I not able to install Power Manager?

Cause : There are two cases in which the installation of Power Manager may fail:

● If you have selected the online updates option in OpenManage Enterprise, check that the connectivity for the online path is successful.

● If you have selected the offline updates option in OpenManage Enterprise, ensure that the ome_powermanager_1.0.0.tar.gz

folder has all the files for the plugin catalog with the sign file and the plugin installer packages, including the RPMs. The installation fails if there is a mismatch between the catalog and .tar files.

Why am I not able to disable or uninstall Power Manager?

Cause : If active policies or an EPR option is enabled, you cannot disable or uninstall Power Manager.

Resolution : Disable the active policies and EPR option, and then try to disable or uninstall Power Manager.

Why are policies being disabled when too many policies are selected for deletion or disable or enable?

Cause : When you select multiple policies for enabling or disabling or deleting, the job is initiated. However, the policies are disabled on the user interface (UI) until the action is complete. After the job is complete, there are entries to the audit logs for these actions.

Why cannot I remove some devices or groups from Power

Manager?

Cause : If you have applied an Emergency Power Reduction (EPR) option on the device or a group, then you cannot remove the device or group from Power Manager.

Resolution : Disable the EPR option on the device or group, and then remove them from Power Manager.

76 Frequently Asked Questions

Why is Power Manager not listed on Console and plugins page?

Cause : Power Manager may not be listed due to the following reasons:

● The offline share folder is not accessible.

● Power Manager plugin and tar folder.s are not present in the offline share folder.

● If the plugin catalog file is edited, then the signature files can get corrupted.

Resolution : Ensure that the offline share folder is reachable through OpenManage Enterprise with the following files:

● ome_powermanager_1.0.0.tar.gz

● plugins_catalog

● plugins_catalog.json.asc

Also, download and replace the corrupt plugins_catalog file.

Why am I not able to apply policies on some devices or groups?

Cause : You can apply a policy only on devices that are supported by Power Manager, having a valid license, and that are added to Power Manager.

You can apply policies on supported PowerEdge servers with iDRAC Enterprise, PowerEdge FX2, FX2s, and VRTX chassis with

CMC Enterprise license.

NOTE: PowerEdge M1000e and PowerEdge MX7000 chassis do not require a CMC Enterprise license.

Why are some alerts not being forwarded using SNMP?

Cause : The following events are not forwarded as SNMP alerts:

● Device membership or group membership changes

● Device management such as change in license status

Alerts are generated by OpenManage Enterprise or Power Manager, that is displayed in the system health category and metric/power configuration subcategory the SNMP trap forwarding is not supported.

Why some email alerts are not getting forwarded?

Cause : The following events are not forwarded as SNMP alerts:

● Device membership or group membership changes.

● Device management such as change in license status.

SNMP trap forwarding is not supported.

Why are some devices automatically removed from Power

Manager?

Cause : If the OpenManage Enterprise Advanced license has expired or is removed from a target node, then the device is removed from Power Manager after the device capability check is run.

Frequently Asked Questions 77

Why do I not see temperature metric for some devices?

Cause : The temperature metric is not visible for devices if they are powered off.

Why can I not select a particular child group?

Cause : When you select a group, all the child groups within this group are also selected. Likewise, when you clear a child group the selection gets cleared at the main group level.

Why am I seeing No Data Available or No

Information available message for some devices metrics?

Cause : When the first metric collection has not yet happened or if the device is not reachable, the following message is displayed: No Data Available

When a device is not added to Power Manager even though it is a supported device, the following message is displayed: No

Information available .

Why are some of the fields in reports empty?

Cause : The fields may be empty in a report due to the following reasons:

● The device was not reachable for that duration.

● That category is not applicable for that device.

● The values are not defined for certain fields in Power Manager and these fields are part of the report.

For example, when you have not configured the power and temperature threshold values for a device, the following fields are added to the report, but the values are not populated:

○ Upper Warning Power

○ Upper Critical Power

○ Lower Critical Temperature

○ Lower Warning Temperature

○ Upper Warning Temperature

○ Upper Critical Temperature

If you have configured the above threshold values and only when the threshold values are violated, the following fields are populated and displayed in the report:

● Lower Critical Violation Count

● Lower Warning Violation Count

● Upper Critical Violation Count

● Upper Warning Violation Count

Why do I not see regular metric data points in the metric graphs?

Cause : A metric graph having irregular metric points indicate that data was not collected for that device at that duration of time.

78 Frequently Asked Questions

Why can I not clear the checkbox for policies?

Cause : The checkbox for policies in the Power Policies page is disabled if that policy is being enabled, disabled, or edited. After the job is completed, you can clear the policy.

How do I see the old metric data?

Cause : The old metric data is not available after a few days because the data is deleted. This configuration depends on the selection of the Delete Power Manager data option available in the Power Manager Preferences section.

Why are the values I set using threshold REST API not configured?

Cause : If you use threshold REST API before installing and adding the devices to Power Manager, the values are not retained.

Resolution : Install and add the devices to Power Manager, and then use the threshold REST APIs.

How to delete power cap from devices when they are removed from Power Manager?

Cause : When a power policy is applied on a static group through Power Manager and a member device is removed from that static group in OpenManage Enterprise, and the policy is active, then the power cap on the device is retained on the management console of the device.

Resolution : To remove the power cap on the device, login to the respective management console and disable the power cap policy.

How to remove EPR on device that was part of deleted physical group

Cause :

Resolution : If one of the devices part of a physical group, have an Emergency Power Reduction (EPR) applied on them, and you delete the physical group from OpenManage Enterprise, the EPR is still active on the device.

Resolution : Though the device being a part of physical group is deleted in OpenManage Enterprise, the device is still part of

Power Manager. To remove EPR on the device:

1. Click Power Manager > Emergency Power Reduction .

The Emergency Power Reduction tab is displayed.

2. Select the device and click Disable .

Frequently Asked Questions 79

17

Troubleshooting

Data purge interval not reset

Scenario :

After reinstalling or updating to the latest version of Power Manager, the data purge interval is not reset to the default value.

Resolution :

Reset the data purge value at the following location after you reinstall or update to the latest version of Power Manager:

OpenManage Enterprise > Application Settings > Console Preferences > Metrics Collection Settings

Failure to add devices in Power Manager

Scenario :

When you rediscover a device or an inventory job is in progress in OpenManage Enterprise, the following error message is displayed: Value entered for id is invalid

Resolution :

Add the devices in Power Manager after the discovery or inventory job is completed.

Why cannot I apply Emergency Power Reduction (EPR) on target device or a group?

Scenario :

When you are trying to apply EPR on a device, the EPR operation may fail and there is an entry in the Audit Logs .

When you are trying to apply EPR option on a group, the EPR operation may fail with the following error message:

The Emergency Power Reduction feature cannot be enabled on the group <group name> because either the member devices of the group cannot be accessed, do not have necessary license, or the Emergency Power Reduction (EPR) feature is already enabled.

Resolution :

Ensure that all the following conditions are met:

● There is at least one device in the group that is eligible for applying EPR.

● Throttle option is applicable for the following devices:

○ If the device is a server, then iDRAC Enterprise license is applied.

○ If the device is PowerEdge M1000e or PowerEdge MX7000 chassis.

● Shutdown option is applicable only for servers.

Power and temperature units are not updated on UI

Scenario :

When you change the power and temperature units in Power Manager through REST APIs and check for the unit change updates in UI, the updates are not reflected on the UI.

Resolution :

To view the updates on the UI after changing the power and temperature units through REST APIs, refresh the browser.

80 Troubleshooting

Why is OpenManage Enterprise unresponsive when I try to perform plugin lifecycle-related actions (install/uninstall/ enable/disable)?

Scenario :

After rebooting OpenManage Enterprise appliance, if you try to perform any plugin lifecycle-related actions for Power Manager, the job is initiated in the back-end but you still see the Console and Plugins page. And, the following message is displayed after some time: This page isn't working

Resolution :

Wait for some time, and view the status. The plugin lifecycle-related action is completed successfully.

Power cap value or the percentage for MX 7000 chassis is not updated when either one of the entries is changed

Scenario :

For an MX7000 chassis, the power cap value is displayed as same as the upper bound value. When you manually change the power cap percentage, the value is not updated and even if you change the value, the percentage is not updated.

Resolution :

Provide the power cap value, and save the policy. The policy imposes the specified power cap value on the selected devices or groups.

Events not generated for alert thresholds

Scenario :

Events are not generated for the following combination of temperature threshold violations:

● Lower Warning to Upper Warning

● Lower Critical to Upper Critical

● Upper Warning to Lower Warning

● Upper Critical to Lower Critical

Resolution :

Provide realistic warning and critical values so that there are no immediate alert generating temperature changes.

Error when removing a device from a group using REST API

Scenario :

When you try to remove a device that is part of multiple groups using the REST API, then an error message is displayed.

Resolution :

To remove a device that is part of multiple groups, remove the device from the group in OpenManage Enterprise. The changes are automatically reflected in Power Manager.

Multiple alerts for group membership changes in Audit Logs

Scenario :

Multiple entries on group membership changes in Audit Logs .

Resolution :

Troubleshooting 81

When devices are simultaneously added to and removed from a static group through OpenManage Enterprise, there are multiple entries of this update in the Audit Logs and Alert Log .

All options for managing physical groups are not displayed

Scenario :

After creating a physical group, you may not see Create New Physical Group , Edit Group , Manage Rack , Delete Group , or

Attributes options when you right-click any group.

Resolution :

As a workaround, wait for some time or refresh the page, and then right-click the group. All the relevant options are displayed.

82 Troubleshooting

18

Appendix

Here are the details about all the filters that are used in the Individual Devices tab of Power Manager.

● Health State indicates the working state of the device. The health status—OK, critical, and warning—are identified by respective color symbols.

Table 21. Device health statuses in OpenManage Enterprise

Health status Definition

Critical

Warning

Ok

Indicates an occurrence of a failure of an important aspect of the device or environment.

The device is about to fail. Indicates that some aspects of the device or environment are not normal. Requires immediate attention.

The device is fully functional.

Unknown The device status is unknown.

● Power State indicates that the device is turned on or off.

● Connection State indicates whether the device is connected to OpenManage Enterprise.

● Name indicates device name.

● Service Tag/Identifier indicates the unique code for the device.

● Model indicates the device model.

● TYPE indicates the type of devices—Server chassis, Dell EMC Storage, and networking switch.

● Managed State indicates the onboarding status of the device.

○ Error : Device cannot be onboarded. Try by logging in by using the recommended privileges in OpenManage Enterprise

User's Guide.

○ Managed : Device successfully onboarded, and can be managed by the OpenManage Enterprise console.

○ Monitored : Device does not have management option (such as the one discovered by using SNMP).

○ Managed with alerts : Device is successfully onboarded, and the OpenManage Enterprise console has successfully registered its IP address with the device as a trap destination during discovery.

○ Proxied : Available only for MX7000 chassis. Indicates that the device is discovered through an MX7000 chassis and not directly.

● Part of Group indicates if the device is part of any group that is monitored in Power Manager.

● State indicates that the Power Manager policy is enabled or disabled.

● Description indicates the device, policy, or job description.

● Hostname indicates the unique name of the device.

● Type indicates static power or temperature-triggered policy.

● Assigned To indicates to which device the policy is assigned to.

● EPR Source indicates if the policy is applied manually or system-triggered policy.

● Size of Device (U) indicates the rack space that is consumed by the device.

● Estimated Max Power (W) indicates the maximum power that is defined for the device.

Appendix 83

19

Other information you may need

In addition to this guide, you can access the following documents that provide more information about Dell EMC OpenManage

Enterprise Power Manager and other related products.

Table 22. Other information you may need

Document

Dell EMC OpenManage

Enterprise Power Manager

Release Notes

Dell EMC OpenManage

Enterprise Power Manager

REST API Guide

Description

Provides information about known issues and workarounds in Power Manager.

Provides information about integrating Power

Manager by using Representational State

Transfer (REST) APIs and also includes examples of using REST APIs to perform common tasks.

Availability

1. Go to Dell.com/OpenManageManuals .

2. Click Dell OpenManage Enterprise and select the required version of OpenManage

Enterprise.

3. Click Manuals & documents to access these documents.

Dell EMC OpenManage

Enterprise User's Guide

Dell EMC OpenManage

Enterprise Release Notes

Provides information about using the features of OpenManage Enterprise.

Provides information about known issues and workarounds in OpenManage Enterprise.

Dell EMC OpenManage

Enterprise Support Matrix

Lists the devices that are supported by

OpenManage Enterprise.

Dell EMC OpenManage

Enterprise and

OpenManage Enterprise -