INSTALLATION

INSTRUCTIONS

QUENTIN™

WIDESPREAD LAVATORY

7440.801

7440.851

FAUCET with Speed Connect

®

Drain

74 4 0 . 8 01

Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.

74 4 0 . 8 5 1

Speed Connect Drain*

• Fewer parts, installs in less time

• Never needs adjustment

• Guaranteed to seal properly the first time, every time.

Certified to comply with ANSI A112.18.1

*Your new American Standard faucet is designed to work only with the Speed Connect drain.

To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

M965238 REV. 1.4 (3/15)

Recommended tools

Tubing Cutter Flat Blade Screwdriver

1

INSTALL SPOUT

CAUTION

Channel Locks

Turn off hot and cold water supplies before beginning.

Seat SEAL (1) into under side of ESCUTCHEON BASE (2) .

Feed FAUCET SUPPLIES (3) , MOUNTING STUD (4) and DRAIN

CABLE ASSEMBLY (5) through the mounting hole of lavatory or mounting surface.

From below, push GASKET (6) with RETAINING WASHER (7) onto

MOUNTING STUD (4) . Secure Faucet with MOUNTING NUT (8) , pushing faucet to back of sink, so SUPPLIES (3) rests against mounting hole.

Adjust Faucet so that it is centered. Tighten MOUNTING NUT (8) to complete faucet mounting.

SPOUT CAN BE FIXED OR SWIVEL.

CONVERT TO A FIXED SPOUT IF DESIRED.

To change from swivel to fixed spout, proceed as follows:

Remove PLUG BUTTON (9) from back of spout. VIEW “A”

Remove SET SCREW (10) using screwdriver.

Install FIXING SET SCREW (11) (supplied with faucet) using Hex Wrench.

Align SPOUT (12) and tighten FIXING SET SCREW (11) to secure SPOUT (12) . Replace PLUG BUTTON (9) .

2

1

3

Adjustable Wrench

74 4 0 . 8 5 1

GROOVE IN

(FAUCET BASE)

4

MOUNTING

SURFACE

74 4 0 . 8 01

9

11

10

VIEW "A"

12

6

7

8

VIEW "A"

9 5

1

2

VALVE INSTALLATION

Place RUBBER RING (1) into DECK ADAPTER (2) .

Install LOCKNUT (3) and RUBBER WASHER (4) onto VALVE BODY (5) .

From under side of mounting surface, install VALVE BODY (5) through valve mounting hole. Threads of VALVE BODY (5) should extent at least 5/16 of a inch above mounting surface top. Fig. A.

Thread DECK ADAPTER (2) onto VALVE BODY (5) until snug against internal stop. If necessary, adjust

LOCKNUT (3) . Tighten LOCKNUT (3) with WRENCH (6) supplied.

2

5/16'' MIN.

2

1

MOUNTING

SURFACE

1

Fig.

A.

4

3

4

3

5

5

6

3

VALVE OUTLET SUPPLY CONNECTION

Connect Red Banded Hose to Left Valve and Blue Banded Hose to Right Valve.

Attach COUPLING NUTS (1) of SUPPLY HOSES (2) and tighten making water tight connections.

Important: Loop SUPPLY HOSES (2) as illustrated so they do not kink.

5

HOT

2

BLUE

BAND

COLD

1

RED BAND

4

INSTALL HANDLES

Push ADAPTER (1) on VALVE STEM (2).

See Fig. A . Tighten

STEM SCREW (3) to secure ADAPTER (1) .

Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting male teeth on ADAPTER (1) to female teeth in HANDLE (4) .

Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5) until snug against mounting surface .

THREAD ON

TO DECK

ADAPTER

TOP

Figure "A"

SPLINE

END DOWN

4

1

3

2

5

M965238 REV. 1.4 (3/15)

5

POP-UP DRAIN

Remove CLEAR PLASTIC COVER (1) .

Remove CARDBOARD SPACER (2) from under

DRAIN POP-UP (3) .

Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig.

B.

Fig.

A.

1

3

2

6

REMOVE FLANGE

Thread FLANGE (1) counter-clockwise and remove

FLANGE (1) and FOAM GASKET (2) from drain body. Fig.

A.

Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against

LOCKNUT (3). Fig.

B.

Fig.

A.

1

2

4

3

Fig.

B.

Fig.

B.

DRAIN

BODY

4

7

INSTALL DRAIN FROM

BELOW FIXTURE

From under side of SINK install DRAIN BODY (1) up through drain outlet.

Note: No plumber’s putty or caulk is required.

The CABLE ATTACHMENT

POINT (2) must face towards the rear of the SINK.

Install FOAM GASKET (3) and

FLANGE (4) onto drain body from above SINK and tighten

FLANGE (4) firmly.

4

3

REAR OF SINK

DRAIN

OUTLET

1

2

8

TIGHTEN LOCKNUT

Tighten LOCKNUT (1) firmly with Adjustable

Wrench or Channel Locks.

9

FLANGE GASKET AND POP-UP KNOB

Check DRAIN FLANGE in SINK to ensure that

WHITE FOAM GASKET (3) is fully compressed and not visible. Fig.

A.

POP-UP KNOB (1) must be fully down. Fig.

B.

Fig.

A.

WHITE FOAM

GASKET

NOT VISIBLE DRAIN

FLANGE

1

1

DOWN

M965238 REV. 1.4 (3/15)

3

10

ATTACH CABLE CONNECTOR

Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig.

A.

Your new POP-UP DRAIN installation is now complete. Fig.

B.

Note: Tailpeice on pop-up drain is 1-1/4” O.D.

Fig.

B.

Fig.

A.

1

Fig.

B.

2

11

CHECK OPERATION OF POP-UP

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.

Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.

12

MAKE WATER SUPPLY AND WASTE CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE

PURCHASED SEPARATELY.

Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE

SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3) . Use adjustable wrench to tighten connections.

Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.

1

2

COUPLING

NUT

3

FERRULE

2

1

1-1/4” O.D.

M965238 REV. 1.4 (3/15)

4

13

TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3) .

Operate both HANDLES (1) to flush water lines thoroughly.

Replace AERATOR (3) .

1

14

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (5) and fill Sink with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Sink. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.

Release POP-UP KNOB (5) down and check all drain connections and "P" trap for leaks. Tighten if necessary.

5

4

1

3

WASTE

OUTLET

2

COLD

2

“P” TRAP

HOT

15

SERVICE

To change direction of handle rotation, proceed as follows:

Turn valve to OFF position.

Thread counter-clock wise HANDLE BASE (1) to remove

HANDLE ASSEMBLY (2) from ESCUTCHEON BASE (3) .

Use a flat blade screw driver to remove SPRING CLIP (4) .

Lift STOP WASHER (5) , turn 90˚ and replace.

Replace SPRING CLIP (4) .

Reinstall HANDLE ASSEMBLY (2) .

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

1 2

5

3

90˚

VALVE

4

16

CARE INSTRUCTIONS:

DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

M965238 REV. 1.4 (3/15)

5

Speed Connect

®

Drain

Troubleshooting Guide

If sink does not hold water even though Stopper is in the “down” position:

• Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

• Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

• Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode .

CABLE ADJUSTMENT PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. Fig.

B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. Fig.

B, C.

Push DOWN on the Lift-Knob to make sure it is fully down. Fig.

C.

Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the

Drain Body Connection (2) and hand-tighten. Fig.

A.

Fig.

A.

Fig.

B.

Fig.

C.

DOWN

1 CAM

RE-ATTACH

CAM CAP

DISCONNECT

2

STOPPER

STOPPER REMOVAL PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig.

B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig.

D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig.

E.

The Stopper can now be removed by lifting it out of the Drain. Fig.

F.

Fig.

D.

Fig.

E.

REMOVE

CAM

Fig.

F.

REMOVE

CAM CAP

M965238 REV. 1.4 (3/15)

6

STOPPER INSTALLATION PROCEDURE

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).

Locked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig.

G.

To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the

Sink and the American Standard logo is facing front . Rotate

Stopper slightly if necessary so that the Stopper slides all the way down.

Fig.

G.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig.

J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig.

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.

LOGO

LOOP TOWARD

REAR OF SINK

DRAIN

Locked Mode

(Vandal Proof)

Fig.

G.

Unlocked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig.

H.

To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the

Sink and the American Standard logo is facing rear . Rotate Stopper slightly if necessary so that the Stopper slides all the way down.

Fig.

H.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig.

J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig.

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

“Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable .

LOGO

180˚

Fig.

LOOP TOWARD

FRONT OF SINK

DRAIN

Unlocked Mode

H.

Fig.

J.

INSTALL CAM

CAM

Fig.

K.

INSTALL

CAM CAP

M965238 REV. 1.4 (3/15)

7

QUENTIN™

WIDESPREAD

LAVATORY FAUCET with Speed Connect ® Drain

MODEL NUMBER

7440.801

7440.851

M964159-YYY0A

HANDLE KIT

M962619-0070A

DECK ADAPTER KIT

M962412-YYY0A

SPOUT SCREW KIT

918555-0070A

HANDLE SCREW

918049-0070A

HANDLE ADAPTER

M964156 -YYY0A

LIFT ROD & KNOB

994053-0070A

CARTRIDGE

M961634-0070A

VALVE

MOUNTING

KIT

A904917-0070A

COUPLING NUT

Replace the "YYY" with appropriate finish code

CHROME

OIL RUBBED BRONZE

SATIN NICKEL

002

224

295

M922894-YYY0A

AERATOR

A911830-0070A

SEAL

M961714-0070A

MOUNTING KIT

M952425-YYY0A

DRAIN ASSEMBLY

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1 (800) 442-1902

Weekdays 8:00 a.m. to 6:00 p.m. EST

IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

IN MEXICO 01-800-839-1200

Product names listed herein are trademarks of American Standard Inc.

© AS America,Inc. 2011

M919660-0020A

6” TAILPIECE

(NOT INCLUDED

WITH FAUCET)

8

M962544-YYY0A

STOPPER

ASSEMBLY

M952430-0070A

CABLE ASSEMBLY

M962457-YYY0A

FLANGE

ASSEMBLY

M922872-0070A

CAM SEAT INSERT

M962552-0070A

CAM ASSEMBLY

M913207-0070A

TAILPIECE INSERT

A919661-0020A

TAILPIECE

M962458-0070A