INSTALLATION
INSTRUCTIONS
QUENTIN™
WIDESPREAD LAVATORY
7440.801
7440.851
FAUCET with Speed Connect
®
Drain
74 4 0 . 8 01
Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.
74 4 0 . 8 5 1
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
Certified to comply with ANSI A112.18.1
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
M965238 REV. 1.4 (3/15)
Recommended tools
Tubing Cutter Flat Blade Screwdriver
1
INSTALL SPOUT
CAUTION
Channel Locks
Turn off hot and cold water supplies before beginning.
Seat SEAL (1) into under side of ESCUTCHEON BASE (2) .
Feed FAUCET SUPPLIES (3) , MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (5) through the mounting hole of lavatory or mounting surface.
From below, push GASKET (6) with RETAINING WASHER (7) onto
MOUNTING STUD (4) . Secure Faucet with MOUNTING NUT (8) , pushing faucet to back of sink, so SUPPLIES (3) rests against mounting hole.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (8) to complete faucet mounting.
SPOUT CAN BE FIXED OR SWIVEL.
CONVERT TO A FIXED SPOUT IF DESIRED.
To change from swivel to fixed spout, proceed as follows:
Remove PLUG BUTTON (9) from back of spout. VIEW “A”
Remove SET SCREW (10) using screwdriver.
Install FIXING SET SCREW (11) (supplied with faucet) using Hex Wrench.
Align SPOUT (12) and tighten FIXING SET SCREW (11) to secure SPOUT (12) . Replace PLUG BUTTON (9) .
2
1
3
Adjustable Wrench
74 4 0 . 8 5 1
GROOVE IN
(FAUCET BASE)
4
MOUNTING
SURFACE
74 4 0 . 8 01
9
11
10
VIEW "A"
12
6
7
8
VIEW "A"
9 5
1
2
VALVE INSTALLATION
Place RUBBER RING (1) into DECK ADAPTER (2) .
Install LOCKNUT (3) and RUBBER WASHER (4) onto VALVE BODY (5) .
From under side of mounting surface, install VALVE BODY (5) through valve mounting hole. Threads of VALVE BODY (5) should extent at least 5/16 of a inch above mounting surface top. Fig. A.
Thread DECK ADAPTER (2) onto VALVE BODY (5) until snug against internal stop. If necessary, adjust
LOCKNUT (3) . Tighten LOCKNUT (3) with WRENCH (6) supplied.
2
5/16'' MIN.
2
1
MOUNTING
SURFACE
1
Fig.
A.
4
3
4
3
5
5
6
3
VALVE OUTLET SUPPLY CONNECTION
Connect Red Banded Hose to Left Valve and Blue Banded Hose to Right Valve.
Attach COUPLING NUTS (1) of SUPPLY HOSES (2) and tighten making water tight connections.
Important: Loop SUPPLY HOSES (2) as illustrated so they do not kink.
5
HOT
2
BLUE
BAND
COLD
1
RED BAND
4
INSTALL HANDLES
Push ADAPTER (1) on VALVE STEM (2).
See Fig. A . Tighten
STEM SCREW (3) to secure ADAPTER (1) .
Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting male teeth on ADAPTER (1) to female teeth in HANDLE (4) .
Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5) until snug against mounting surface .
THREAD ON
TO DECK
ADAPTER
TOP
Figure "A"
SPLINE
END DOWN
4
1
3
2
5
M965238 REV. 1.4 (3/15)
5
POP-UP DRAIN
Remove CLEAR PLASTIC COVER (1) .
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3) .
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig.
B.
Fig.
A.
1
3
2
6
REMOVE FLANGE
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain body. Fig.
A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against
LOCKNUT (3). Fig.
B.
Fig.
A.
1
2
4
3
Fig.
B.
Fig.
B.
DRAIN
BODY
4
7
INSTALL DRAIN FROM
BELOW FIXTURE
From under side of SINK install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body from above SINK and tighten
FLANGE (4) firmly.
4
3
REAR OF SINK
DRAIN
OUTLET
1
2
8
TIGHTEN LOCKNUT
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
9
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed and not visible. Fig.
A.
POP-UP KNOB (1) must be fully down. Fig.
B.
Fig.
A.
WHITE FOAM
GASKET
NOT VISIBLE DRAIN
FLANGE
1
1
DOWN
M965238 REV. 1.4 (3/15)
3
10
ATTACH CABLE CONNECTOR
Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig.
A.
Your new POP-UP DRAIN installation is now complete. Fig.
B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig.
B.
Fig.
A.
1
Fig.
B.
2
11
CHECK OPERATION OF POP-UP
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.
Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.
12
MAKE WATER SUPPLY AND WASTE CONNECTIONS
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3) . Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.
1
2
COUPLING
NUT
3
FERRULE
2
1
1-1/4” O.D.
M965238 REV. 1.4 (3/15)
4
13
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3) .
Operate both HANDLES (1) to flush water lines thoroughly.
Replace AERATOR (3) .
1
14
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (5) and fill Sink with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Sink. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.
Release POP-UP KNOB (5) down and check all drain connections and "P" trap for leaks. Tighten if necessary.
5
4
1
3
WASTE
OUTLET
2
COLD
2
“P” TRAP
HOT
15
SERVICE
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position.
Thread counter-clock wise HANDLE BASE (1) to remove
HANDLE ASSEMBLY (2) from ESCUTCHEON BASE (3) .
Use a flat blade screw driver to remove SPRING CLIP (4) .
Lift STOP WASHER (5) , turn 90˚ and replace.
Replace SPRING CLIP (4) .
Reinstall HANDLE ASSEMBLY (2) .
If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.
1 2
5
3
90˚
VALVE
4
16
CARE INSTRUCTIONS:
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M965238 REV. 1.4 (3/15)
5
Speed Connect
®
Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode .
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.
A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig.
B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig.
B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig.
C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig.
A.
Fig.
A.
Fig.
B.
Fig.
C.
DOWN
1 CAM
RE-ATTACH
CAM CAP
DISCONNECT
2
STOPPER
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.
A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig.
B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig.
D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig.
E.
The Stopper can now be removed by lifting it out of the Drain. Fig.
F.
Fig.
D.
Fig.
E.
REMOVE
CAM
Fig.
F.
REMOVE
CAM CAP
M965238 REV. 1.4 (3/15)
6
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig.
G.
To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front . Rotate
Stopper slightly if necessary so that the Stopper slides all the way down.
Fig.
G.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig.
J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig.
K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.
LOGO
LOOP TOWARD
REAR OF SINK
DRAIN
Locked Mode
(Vandal Proof)
Fig.
G.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig.
H.
To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear . Rotate Stopper slightly if necessary so that the Stopper slides all the way down.
Fig.
H.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig.
J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig.
K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable .
LOGO
180˚
Fig.
LOOP TOWARD
FRONT OF SINK
DRAIN
Unlocked Mode
H.
Fig.
J.
INSTALL CAM
CAM
Fig.
K.
INSTALL
CAM CAP
M965238 REV. 1.4 (3/15)
7
QUENTIN™
WIDESPREAD
LAVATORY FAUCET with Speed Connect ® Drain
MODEL NUMBER
7440.801
7440.851
M964159-YYY0A
HANDLE KIT
M962619-0070A
DECK ADAPTER KIT
M962412-YYY0A
SPOUT SCREW KIT
918555-0070A
HANDLE SCREW
918049-0070A
HANDLE ADAPTER
M964156 -YYY0A
LIFT ROD & KNOB
994053-0070A
CARTRIDGE
M961634-0070A
VALVE
MOUNTING
KIT
A904917-0070A
COUPLING NUT
Replace the "YYY" with appropriate finish code
CHROME
OIL RUBBED BRONZE
SATIN NICKEL
002
224
295
M922894-YYY0A
AERATOR
A911830-0070A
SEAL
M961714-0070A
MOUNTING KIT
M952425-YYY0A
DRAIN ASSEMBLY
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
Product names listed herein are trademarks of American Standard Inc.
© AS America,Inc. 2011
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
8
M962544-YYY0A
STOPPER
ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M962457-YYY0A
FLANGE
ASSEMBLY
M922872-0070A
CAM SEAT INSERT
M962552-0070A
CAM ASSEMBLY
M913207-0070A
TAILPIECE INSERT
A919661-0020A
TAILPIECE
M962458-0070A
DRAIN MOUNTING KIT