Vents VK User Manual

Add to My manuals
16 Pages

Vents VK centrifugal inline fan is designed for efficient supply or exhaust ventilation of various premises. It can be used to connect to air ducts of different diameters, ranging from 100 to 315 mm. The fan is equipped with a reliable asynchronous motor and features low noise operation. Some models come with additional options like a speed controller or a built-in timer. Vents VK fans are suitable for various applications, including ventilation of bathrooms, kitchens, offices, and other residential or commercial spaces.

advertisement

Vents VK User Manual | Manualzz

USER'S MANUAL

VK

Centrifugal fan

VK

CONTENTS

Contents .............................................................................................................................................................................................. 2

Safety requirements ..................................................................................................................................................................... 3

Purpose ................................................................................................................................................................................................ 5

Delivery set ........................................................................................................................................................................................ 5

Designation key .............................................................................................................................................................................. 5

Technical data .................................................................................................................................................................................. 6

Design and operating principle ........................................................................................................................................... 7

Mounting and set-up .................................................................................................................................................................. 8

Connection to power mains .................................................................................................................................................. 9

Technical maintenance .............................................................................................................................................................. 10

Storage and transportation regulations .......................................................................................................................... 10

Manufacturer’s warranty ........................................................................................................................................................... 11

Certificate of acceptance ........................................................................................................................................................ 12

Seller information .......................................................................................................................................................................... 12

Installation certificate .................................................................................................................................................................. 12

Warranty card ................................................................................................................................................................................. 12

This user’s manual is a main operating document intended for technical, maintenance, and operating staff.

The manual contains information about purpose, technical details, operating principle, design, and installation of the VK unit and all its modifications.

Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.

2 www.ventilation-system.com

SAFETY REQUIREMENTS

All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical norms and standards must be observed when installing and operating the unit.

Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and repair operations.

Only qualified electricians with a work permit for electrical units up to 1000 V are allowed for installation and maintenance. The present user’s manual should be carefully read before beginning works.

• Check the unit for any visible damage of the impeller, the casing, and the grille before starting installation. The casing internals must be free of any foreign objects that can damage the impeller blades.

• While mounting the unit, avoid compression of the casing! Deformation of the casing may result in motor jam and excessive noise.

• Misuse of the unit and any unauthorised modifications are not allowed.

• Do not expose the device to adverse atmospheric agents (rain, sun, etc.).

• Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous materials.

• Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, insecticides, etc.

• Do not close or block the intake or extract vents in order to ensure the efficient air flow.

• Do not sit on the unit and do not put objects on it.

• The information in this user’s manual was correct at the time of the document’s preparation.

• The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time in order to incorporate the latest technological developments.

WARNING! Similar to the use of any other household electrical appliances when operating this fan, the following basic rules must be followed:

• Never touch the unit with wet or damp hands.

• Never touch the unit when barefoot.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

www.ventilation-system.com

3

The connection to the supply mains must be made through a means of disconnection, which is incorporated in the fixed wiring in accordance with the wiring rules, and has a contact separation in all poles that allows for full disconnection under overvoltage category III conditions.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a safety hazard.

CAUTION: In order to avoid a safety hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.

VK

Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances.

Ensure that the appliance is switched off from the supply mains before removing the guard.

WARNING: If there are any unusual oscillating movements, immediately stop using the appliance and contact the manufacturer, its service agent or suitably qualified persons.

The replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.

4

THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.

DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE.

www.ventilation-system.com

PURPOSE

The product described herein is a centrifugal inline fan for supply or exhaust ventilation of premises.

The fan is designed for connection to ø 100, 125, 150, 200, 250 and 315 mm air ducts.

A model with a duct diameter of 150 mm can be mounted in a duct with a diameter of 150 or 160 mm.

THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED

PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT THE APPROPRIATE

TRAINING.

THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED

PERSONNEL AFTER THE APPROPRIATE BRIEFING.

THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORISED

ACCESS BY UNATTENDED CHILDREN.

Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials, coarse dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust, pathogenic germs).

DELIVERY SET

Name

Fan

Screws and dowels

Mounting bracket

User’s manual

Packing box

Number

1 pc.

4 pcs.

2 pcs.

1 pc.

1 pc.

DESIGNATION KEY

VK 100 Duo U 220V/60 Hz

Network parameters

_: 220-240 V/50 Hz

220 V/60 Hz: supply voltage 220 V, supply frequency 60 Hz

Additional options

Q : low-powered motor

U : speed controller with an electronic thermostat and an integrated temperature sensor.

Temperature-based operation logic

U1 : speed controller with an electronic thermostat and an integrated temperature sensor.

Timer-based operation logic

Un : speed controller with an electronic thermostat and an external temperature sensor fixed on a

4-meter cable. Temperature-based operation logic

U1n : speed controller with an electronic thermostat and an external temperature sensor fixed on a

4-meter cable. Timer-based operation logic

U2 : speed controller with an electronic thermostat and an integrated temperature sensor.

Temperature-based switching on/off

U2n : speed controller with an electronic thermostat and an external temperature sensor fixed on a

4-meter cable. Temperature-based switching on/off

P : integrated smooth speed controller

V : built-in speed switch (for two-speed motors)

R1 : cable with a mains plug

Motor

_ : asynchronous;

Duo : double-speed motor.

Air duct diameter [mm]

100; 125; 150; 200; 250; 315

Unit series

VK : Centrifugal fan

VKS : Centrifugal fan with a high-powered motor www.ventilation-system.com

5

VK

TECHNICAL DATA

The fan is designed for indoor application with the ambient temperature ranging from +1 °C up to +45 °C and relative humidity up to 80 %. Hazardous parts access and water ingress protection rating is IPX4.

The unit is rated as a class II electric appliance.

The unit design is constantly being improved, thus some models may be slightly different from those described in this manual.

Parameter

Voltage [V]

Frequency

Power [W]

Current [A]

Maximum air flow [m 3 /h]

RPM [min -1 ]

Maximum transported air temperature [°C]

Ingress protection rating

Parameter

Voltage [V]

Frequency

Power [W]

Current [A]

Maximum air flow

[m 3 /h]

RPM [min -1 ]

Maximum transported air temperature [°C]

Ingress protection rating

50

107

0.47

780

2660

VK 200

60

132

0.58

890

2765

VK 100 Q

50

62

0.38

205

2650

-25...+60

60

63

0.38

210

2710

50

80

0.34

250

2820

VK 100

60

81

0.34

290

2890

50

61

VK 125 Q

1~220-240

60

64

0.38

260

2610

0.4

270

2680

50

79

0.34

355

2800

VK 125

60

81

0.35

370

2830

50

80

0.35

460

2725

VK 150

60

84

0.37

505

2840

-25...+40 -25...+60 -25...+40 -25...+60 -25...+40 -25...+60 -25...+40 -25...+60 -25...+40

IPХ4

VKS 200

50

173

0.76

930

2125

60

216

0.94

1020

2155

50

VK 250 Q

1~220-240

60

108

0.47

135

0.59

865 930

2560 2570

IPХ4

50

173

0.76

1080

2090

VK 250

60

207

0.9

1090

2120

50

200

0.88

1340

2655

VK 315

60

213

0,95

1290

2590

VKS 315

50

310

1.36

1700

2590

-25...+60 -25...+40 -25...+60 -25...+40 -25...+60 -25...+40 -25...+60 -25...+40 -25...+60 -25...+40 -25...+60

Parameter

Speed

Voltage [V]

Power [W]

Current [A]

Maximum air flow [m 3 /h]

RPM [min -1 ]

Maximum transported air temperature [°C]

Ingress protection rating

Parameter

Speed

Voltage [V]

Power [W]

Current [A]

Maximum air flow [m 3 /h]

RPM [min -1 ]

Maximum transported air temperature [°C]

Ingress protection rating

VK 100 Duo min max

45

0.21

157

1820

57

0.25

264

2440

VK 125 Duo min max

45

0.21

191

1810

VK 150 Duo min max

1~230

58

0.26

329

46

0.22

264

2380

-25...+60

1805

59

0.26

445

2420

IPX4

VK 250 Duo VK 315 Duo

VK 200 Duo min max

83

0.37

430

1920

95

0.43

741

2470 min max min max

1~ 230 1~ 230

147

0.66

642

1940

176

0.76

1126

2370

-25...+60

IPX4

143

0.68

758

1870

173

0.76

1268

2410

6 www.ventilation-system.com

Model

D

VK 100 Q/VK 100/VK 100 Duo 100

VK 125 Q/VK 125/VK 125 Duo 125

VK 150/VK 150 Duo

VK 200/VK 200 Duo

150/160

200

VKS 200 200

VK 250 Q/VK 250/VK 250 Duo 250

VK 315/VK 315 Duo

VKS 315

315

315

Overall dimensions of the unit [mm]

Dimensions [mm]

D1 B

250

250

270

270

300

340

340

340

400

400

310

354

354

354

414

414

L

230

220

286

276

276

265

276

276

Weight

[kg]

2.01

2.2

2.45

3.0

4.3

4.3

4.85

4.85

DESIGN AND OPERATING PRINCIPLE

4

5

3

2

1. Casing

2. Motor

3. Impeller

4. Mounting bracket

5. Terminal box

1

The fan is equipped with a single-phase motor with an external rotor, equipped with a centrifugal impeller. The Duo models are supplied with a two-speed asynchronous motor.

The fan is rated for continuous operation.

Electronics operation algorithm

The VK U / U1 / U2 fan is equipped with an electronic module TSC (speed controller with an electronic thermostat) for automatic speed control (air flow) depending on the air temperature.

The terminal compartment incorporates 2 control knobs: Temperature regulator

• presetting speed

• setting electric thermostat threshold value

The fan is equipped with two indicators:

• temperature sensor indicator (hereinafter referred to as TSI) - yellow colour

Air flow regulator

• motor control indicator (hereinafter referred to as MCI) - green/yellow colour

When the fan turns on, the TSI indicates the unit operation algorithm:

• one pulse - U

• two pulses - U1

22

23

21

20°C

24

25

26

27

28

29

30°C min max

• three pulses - U2

The MCI lights up in green when the motor rotates and in red when it stops (or rotates very slowly).To set the thermostat threshold, rotate the thermostat control knob clockwise to increase or counter-clockwise to decrease the temperature set point. To set the fan speed (air flow), rotate the speed control knob in the same way.

VK U : In this case, fan speed switching operations are rare.

The TSI lights up and the fan switches to the maximum speed as the room air temperature exceeds the set point.

As the air temperature drops 2 °C below the set point or if the initial temperature is below the set point, the TSI goes out and the fan operates with the set speed.

VK U1 : The speed switching operations are more frequent as compared to the temperature-based functioning logic (U), but one speed interval continues at least 5 minutes.

The TSI lights up and the fan switches to the maximum speed as the room air temperature exceeds the set point.

As the air temperature drops down below the set point, the TSI starts blinking, the timer starts a 5-minute countdown and then the fan switches to the set lower speed and the TSI goes out.

VK U2 : The fan starts only at a certain air temperature.

The TSI lights up and the fan switches to the set speed as the room air temperature exceeds the set point.

As the air temperature drops 2 °C below the set point or if the initial temperature is below the set point, the TSI goes out and the fan turns off.

www.ventilation-system.com

7

1

3

8

5

Two short pulses

One pulse

The motor shuts down

Alarm code

MOUNTING AND SET-UP

Temperature sensor failure

Alarm description

Short circuit of the temperature sensor

Breakdown of the temperature sensor

READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT.

The fan is suitable both for horizontal or vertical mounting on the floor, on the wall or on the ceiling. Air motion in the system must be in compliance with the direction of the arrow on the fan casing. Install a hood on the intake spigot side in case of vertical fan installation. When installing the fan horizontally, provide a straight air duct section at least 1 m long on the intake spigot side.

1 m

9

VK

Mounting sequence:

1. Remove the bolts on both sides of the casing, install the mounting brackets and tighten the bolts, aligning the holes in the brackets with the holes in the casing.

2. Mark holes for drilling.

3. Drill the holes in the wall or the ceiling for dowels.

4. Fix the fan with the screws.

5. Connect the air ducts of the corresponding diameter to the fan.

2

4 www.ventilation-system.com

CONNECTION TO POWER MAINS

POWER OFF THE POWER SUPPLY PRIOR TO ANY OPERATIONS WITH THE UNIT.

THE UNIT MUST BE CONNECTED TO POWER SUPPLY BY A QUALIFIED ELECTRICIAN.

THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE GIVEN ON THE

MANUFACTURER’S LABEL.

ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED

AND WILL VOID THE WARRANTY.

• The unit is rated for connection to power mains with the parameters specified in the "Technical specifications” section, according to the wiring diagram.

• The connection must be made using durable, insulated and heat-resistant conductors (cables, wires).

• The actual wire cross section selection must be based on the maximum load current, maximum conductor temperature depending on the wire type, insulation, length and installation method.

• The external power input must be equipped with an automatic circuit breaker QF built into the stationary wiring to open the circuit in the event of overload or short-circuit.

• The position of the external automatic circuit breaker must ensure free access for quick power-off of the unit.

• The trip current of the automatic circuit breaker must exceed the maximum current consumption of the unit (refer to the “Technical data” section or to the unit label).

• The recommended trip current of the circuit breaker is the next current in the standard trip current row following the maximum current of the connected unit.

• The circuit breaker is not included in the delivery set and can be ordered separately.

Diagram 1

Connection of the fan to power mains

QF

WIRING DIAGRAM

Diagram 2

Connection of the fan to power mains with an external switch

QF

X X

N N N N

S

L L L

L

L

QF

Diagram 3

Connection of the Duo fan to power mains

S

L1

L2

N N

Designation:

L – line; N – neutral; QF – automatic circuit breaker; S – external switch (Diagrams 1, 2);

S – switch (Diagram 3); X – input terminal block

X www.ventilation-system.com

9

TECHNICAL MAINTENANCE

DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE

OPERATIONS!

ENSURE THAT THE UNIT IS SWITCHED OFF FROM THE SUPPLY MAINS BEFORE

REMOVING THE GUARD.

Clean the product surfaces regularly (once in 6 months) from dust and dirt. To clean the fan, remove the self-tapping screws and remove the fan cover. To clean the fan, use a soft cloth or a brush wetted in a mild detergent solution.

Do not allow water or liquid come into contact with electric components. Wipe the unit surfaces dry after cleaning.

Install the cover back in place and screw the self-tapping screws.

VK

1 2

15

3 4

15

5 6

STORAGE AND TRANSPORTATION REGULATIONS

• Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range from +5 ˚С to +40 ˚С and relative humidity up to 70 %.

• Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing deformation.

• Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit.

• Follow the handling requirements applicable for the particular type of cargo.

• The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage. The unit must be transported only in the working position.

• Avoid sharp blows, scratches, or rough handling during loading and unloading.

• Prior to the initial power-up after transportation at low temperatures, allow the unit to warm up at operating temperature for at least 3-4 hours.

10 www.ventilation-system.com

MANUFACTURER’S WARRANTY

The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European

Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking

Council Directive 93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above.

The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user's observance of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the course of the unit operation through the Manufacturer's fault during the guaranteed period of operation, the user is entitled to get all the faults eliminated by the manufacturer by means of warranty repair at the factory free of charge. The warranty repair includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation. The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component.

The warranty repair does not include:

• routine technical maintenance

• unit installation/dismantling

• unit setup

To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the payment paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact the Seller for warranty service.

The manufacturer’s warranty does not apply to the following cases:

• User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing component parts previously dismounted by the user.

• Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's manual.

• User’s failure to ensure timely technical maintenance of the unit.

• External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user.

• Redesign or engineering changes to the unit.

• Replacement and use of any assemblies, parts and components not approved by the manufacturer.

• Unit misuse.

• Violation of the unit installation regulations by the user.

• Violation of the unit control regulations by the user.

• Unit connection to power mains with a voltage different from the one stated in the user's manual.

• Unit breakdown due to voltage surges in power mains.

• Discretionary repair of the unit by the user.

• Unit repair by any persons without the manufacturer’s authorization.

• Expiration of the unit warranty period.

• Violation of the unit transportation regulations by the user.

• Violation of the unit storage regulations by the user.

• Wrongful actions against the unit committed by third parties.

• Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).

• Missing seals if provided by the user’s manual.

• Failure to submit the user’s manual with the unit purchase date stamp.

• Missing payment paperwork certifying the unit purchase.

FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND

TROUBLE-FREE OPERATION OF THE UNIT.

USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION

OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH THE

PURCHASE DATE STAMP.

www.ventilation-system.com

11

CERTIFICATE OF ACCEPTANCE

Unit Type

Model

Serial Number

Manufacture Date

Quality Inspector’s

Stamp

Centrifugal fan

VK __________

SELLER INFORMATION

Seller

Address

Phone Number

E-mail

Purchase Date

This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.

Customer’s Signature

INSTALLATION CERTIFICATE

The VK __________ unit is installed pursuant to the requirements stated in the present user's manual.

Company name

Address

Phone Number

Installation

Technician’s Full Name

Installation Date: Signature:

The unit has been installed in accordance with the provisions of all the applicable local and national construction, electrical and technical codes and standards. The unit operates normally as intended by the manufacturer.

Signature:

WARRANTY CARD

Unit Type

Model

Serial Number

Manufacture Date

Purchase Date

Warranty Period

Seller

Centrifugal fan

VK __________

Seller’s Stamp

Installation Stamp

Seller’s Stamp

VK

12 www.ventilation-system.com

www.ventilation-system.com

13

VK

14 www.ventilation-system.com

www.ventilation-system.com

15

V02EN-14