Hearth and Home Technologies SILH30E-B Indoor Fireplace Owner's Manual

Add to My manuals
24 Pages

advertisement

Hearth and Home Technologies SILH30E-B Indoor Fireplace Owner's Manual | Manualzz

Owner’s Manual

Installation and Operation

Models:

SILH30E-B

Electric Fireplace/Insert

CAUTION

DO NOT DISCARD THIS MANUAL

operating understand a n d m a i n t e n a n c e a n d f o l l o w t h e s e instructions included.

instructions for safe i n s t a l l a t i o n a n d operation.

party responsible for use and operation.

NOT

WARNING

If the information in these instructions is not followed exactly, a fi re may result causing property damage, personal injury, or death.

• Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.

• Comply with all minimum clearances to combustibles as specifi ed. Failure to comply may cause house fi re.

Made in China

WARNING

HOT! DO NOT TOUCH .

SEVERE BURNS MAY RESULT.

CLOTHING IGNITION MAY RESULT.

Glass and other surfaces are hot during operation and cool down.

• CAREFULLY SUPERVISE children in same room as heater.

• Alert children and adults to hazards of high temperatures.

• Keep clothing, furniture, draperies and other combustibles away.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 1

Read this manual before installing or operating this heater.

Please retain this owner’s manual for future reference.

Congratulations!

Congratulations on selecting a Heatilator electric fi replace/ insert. The insert you have selected is designed to provide the utmost in safety, reliability and effi ciency.

The information contained in this owner’s manual unless noted otherwise, applies to all models.

As the owner of a new fi replace/insert, you’ll want to read and carefully follow all of the instructions contained in this owner’s manual. Pay special attention to all cautions and warnings.

Your new Heatilator electric fi replace/insert will give you years of durable use and trouble-free enjoyment. Welcome to the

Heatilator family of fi replace products!

This owner’s manual should be retained for future reference.

We suggest you keep it with your other important documents and product manuals.

Homeowner Reference Information

Model Name:

Serial Number:

Dealership purchased from:

Notes:

We recommend that you record the following pertinent information about your heater:

Date purchased/installed:

Location on heater:

Dealer phone:

Listing Label Information/Location

The model information regarding your specifi c heater can be found on the rating plate located in the upper left corner of the fi rebox opening.

2

Heater

Model

Serial #

Hearth & Home Technologies Inc.

1915 W. Saunders Street

Mt. Pleasant, IA 52641

UL 2021 FIXED AND LOCATION

DEDICATED ELECTRIC ROOM HEATER

MODEL XXXX DATE

SERIAL XXXXXXX

Made in China

VOLTS: 120V

WATTS: 1500W

FREQUENCY:60Hz

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

Table of Contents

1 Listing and Code Approvals

A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . 4

B. Important Instructions . . . . . . . . . . . . . . . . . . . . . . . . . 4

A. Design and Installation Considerations . . . . . . . . . . . . 5

B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . 5

C. Inspect Heater and Components . . . . . . . . . . . . . . . . . 5

3 Framing and Clearances

A. Selecting Heater Location . . . . . . . . . . . . . . . . . . . . . . 6

B. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

C. Frame the Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

4 Installation

A. As a Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

B. As an Insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

C. Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

5 Accessories

A. Install the Front Face . . . . . . . . . . . . . . . . . . . . . . . . . 13

B. Install other Optional Accessories . . . . . . . . . . . . . . . 13

6 Finishing

A. Finishing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

B. Finishing Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . 14

C. Mantel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

8 Troubleshooting

A. Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . 16

9 Maintenance and Service

A. Access the Firebox . . . . . . . . . . . . . . . . . . . . . . . . . . 17

B. Clean the Firebox Compartment . . . . . . . . . . . . . . . . 17

C. Clean the Back Glass . . . . . . . . . . . . . . . . . . . . . . . . 17

D. Replace the Light Bulbs . . . . . . . . . . . . . . . . . . . . . . 17

E. Maintenance Task List . . . . . . . . . . . . . . . . . . . . . . . . 18

A. Heater Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 19

B. Heater Components . . . . . . . . . . . . . . . . . . . . . . . . . 20

C. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

D. Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

E. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . 27

A. Main Power Switch . . . . . . . . . . . . . . . . . . . . . . . . . . 15

B. Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Note: An arrow ( ) found in the text signifi es change in content.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 3

1

Listing and Code Approvals

A. Certifi cation

This heater has been tested in accordance with the UL2021

Standards for fi xed and location-dedicated electric room heaters in the United States, the current CSA C22.2 No. 46 in Canada and has been listed by Underwriters Laboratories

Inc. for installation as described in this manual. All components are UL or CSA safety certifi ed.

This heater has been tested and listed for use with the optional components specifi ed in this manual. These optional components may be purchased separately and installed at a later date.

Heatilator is a registered trademark of Hearth & Home Technologies Inc.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

Refer to the owner’s information manual provided with this heater. For assistance or additional information consult a qualifi ed installer, service agency or your dealer.

Not intended for use as a primary heat source.

This heater is tested and approved as a decorative heater.

It should not be factored as a primary heat source in residential heating calculations.

• Do not

WARNING

Fire Risk install or operate damaged heater.

• Do not modify heater.

• Installation other than as instructed by Hearth & Home

Technologies Inc. is strictly prohibited.

• Do not operate the heater without fully assembling all components.

• Installation and/or use of any component part not approved by Hearth & Home Technologies.

Hearth & Home Technologies disclaims any responsibility for, and the warranty and agency listing will be voided by the above actions.

B. Important Instructions

When using electrical heaters, basic precautions should always be followed to reduce the risk of fi re, electric shock, and injury to persons, including the following:

• Read all instructions before using this heater.

• This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and

curtains at least 12 in. (305 mm) from the front of the heater and keep them away from the sides and rear.

• Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.

• Always unplug heater when not in use.

• Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped or damaged in any manner. Return heater to authorized service facility for examination, electrical or mechanical adjustment, or repair.

• Do not use outdoors.

4

• This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.

• Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord away from traffi c area and where it will not be tripped over. Do not coil cord.

• To disconnect heater, turn controls to “OFF”, then remove plug from outlet.

• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fi re, or damage the heater.

• To prevent a possible fi re, do not block air intakes or exhaust in any manner.

• A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or fl ammable liquids are used or stored.

• Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fi re, electric shock, or injury to persons.

• Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fi re. However, if you have to use an extension cord, the cord shall be No. 16

AWG minimum size and rated not less than 1875 watts.

Use minimum length and do not coil cord.

• Always use properly grounded fused and polarized outlets.

• Always use ground fault protection where required by electrical code.

• Always disconnect power before performing any cleaning, maintenance or relocation of the heater.

• To prevent a possible fi re, do not burn wood or other materials in this heater.

To prevent electric shock or fi re, always use a certifi ed electrician should new circuits or outlets be required.

• When transporting or storing the heater, keep in a dry place free from excessive vibration and store as to avoid damage.

S AV E T H E S E I N S T R U C T I O N S F O R F U T U R E

REFERENCE.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

2

Getting Started

A. Design and Installation Considerations

CAUTION

Check building codes prior to installation.

• Installation MUST comply with local, regional, state and national codes and regulations.

• Consult insurance carrier, local building inspector, fi re offi cials or authorities having jurisdiction about restrictions, installation inspection, and permits.

C. Inspect Heater and Components

CAUTION

Sharp Edges and safety glasses during installation.

When planning a heater installation, it is necessary to determine the following information before installing:

• Where the heater is to be installed. See Sections

3 and 4.

• Electrical wiring. See Section 4.

• Framing and fi nishing details. See Sections 3 and 6.

• Whether optional accessories—devices such as a fan, wall switch or remote control —are desired. See Section 10.

WARNING

Fire Risk

Inspect heater and components for damage.

Damaged parts may impair safe operation.

• Do NOT install damaged components.

• Do NOT install incomplete components.

• Do NOT install substitute components

Report damaged parts to dealer.

B. Tools and Supplies Needed

Before beginning the installation be sure the following tools and building supplies are available:

Reciprocating saw Framing material

Hammer Gloves

Phillips screwdriver Framing square

Flat blade screwdriver Electric drill and bits

Plumb line Safety glasses

• Carefully remove the heater and components from the packaging.

• Report to your dealer any parts damaged in shipment.

• Read all the instructions before starting the installation.

Follow these instructions carefully during the installation to ensure maximum safety and benefi t.

Surround

1/2-3/4 in. length, #6 or #8 self-drilling screws

Misc. screws and nails

CAUTION

• Mold or rust may cause odors.

Note: Minimum and maximum clearances must be maintained at all times. Illustrations throughout these instructions refl ect typical installations and are for design purposes only. Actual installation may vary slightly due to individual design preferences.

The illustrations and diagrams used throughout these installation instructions are not drawn to scale.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 5

3

Framing and Clearances

WARNING

Fire Risk

Provide adequate clearances.

• Around air openings

• For service access.

Locate heater away from traffi c areas.

Note:

• Illustrations and photos refl ect typical installations and are FOR DESIGN PURPOSES ONLY.

• Illustrations/diagrams are not drawn to scale.

• Actual installation/appearance may vary due to individual design preference.

• Hearth & Home Technologies reserves the right to alter its products.

A. Selecting Heater Location

Several options are available to you when choosing a location for your heater. This heater may be used as a room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 3.1. This heater may be installed directly on the fl oor, carpet or raised on a hearth.

B. Clearances

Figure 3.1 shows all clearances that must be maintained around the heater.

WARNING

DANGER

Electrocution Risk

• NEVER locate this heater where it may fall into a bathtub or other water container.

Fire Risk

Due to high temperature, this heater should be located out of high traffi c areas.

• Keep combustible materials such as furniture, pillows, bedding, papers, clothes and curtains at least 12 in.

(305 mm) from the front of the heater .

WARNING

Fire Risk!

• Prevent contact with sagging, loose insulation.

• Do NOT install against vapor barriers or exposed insulation.

WARNING

Do NOT use this heater if any part has been under water.

Immediately call a qualifi ed service technician to inspect the heater and to replace any part of the control system which has been under water.

6 Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

WARNING

Fire Risk

• Comply with all minimum clearances to combustibles as specifi ed.

Failure to comply may cause fi re.

Note: Minimum and maximum clearances must be maintained at all times. Illustrations throughout these instructions refl ect typical installations and are for design purposes only. Actual installation may vary slightly due to individual design preferences.

The illustrations and diagrams used throughout these installation instructions are not drawn to scale.

D

C

A

B

A

A

9-3/4 in.

(248 mm)

1/2 in. min.

(13 mm)

9-3/4 in.

(248 mm)

1 in. min.

(26 mm)

Model A B C D inches 26-1/2 37 18-1/2 26-1/8

SILH30E-B mm 673 940 470 664

Figure 3.1 Heater Locations

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 7

C. Frame the Heater

Figure 3.2 shows a typical framing (using 2 x 4 lumber) of the heater, assuming combustible materials are used. All required clearances to combustibles around the heater must be adhered to.

22-7/8 in.

(581 mm)

(header height)

NOTE: The height that a combustible mantel is fitted above the heater is dependent on the height of the front selected. The minimum height is 1 in.

(25 mm) above the front. Fronts are available in 24 in. (610 mm), 28 in.

(711 mm) and 32 in. (813 mm) high.

26-1/2 in.

(673 mm)

9-3/4 in.

(248 mm)

Figure 3.2 Framing the Heater

8 Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

4

Installation

CAUTION

Sharp Edges

• Wear protective gloves and safety glasses during installation.

A. As a Fireplace

Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high traffi c areas.

Note: Follow all national and local electrical codes.

WARNING

Shock Risk

Improperly grounded outlets could cause electrical shock.

• Always use properly grounded, fused and polarized outlets.

• Always use ground fault protection where required by electrical code.

WARNING

Shock Risk

Fire Risk

Improperly protected power cords could cause electrical shock or fi re.

• Do not pinch the cord or lay against a sharp object.

• Do not cover the cord with carpeting, throw rugs or runners.

• Secure and arrange cord to avoid a tripping hazard.

Cabinet Installation

The Cabinet must provide access to the wall outlet.

• For ease of electrical hookup, you may wish to install the heater near an existing outlet. A 15 amp, 120 volt circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit trips or fuse blows on a regular basis while the heater is operating. Additional heaters on the same circuit may exceed the current rating of the circuit breaker.

• If using a wall cabinet or corner cabinet, refer to the installation instructions supplied with the kit. For custom cabinets, frame and construct with the opening and depth dimensions listed in Figures 3.1 and 3.2.

• Before plugging the heater into the wall outlet, make sure all control switches are in the “OFF” position.

cabinet and the power cord routed to the electrical outlet.

If the power cord does not reach the outlet, a No. 16-AWG minimum wire size extension cord rated for a minimum of

1875 watts may be used. Use minimum length and do not coil cord.

• To complete the heater installation, refer to Section 5.

Non-Cabinet or Chase Installation

• Follow recommended framing dimensions in Figures 3.1 and 3.2.

• Set the heater into the framed opening. Secure the heater in place using the nailing fl anges on both sides of the heater and nail to the framing.

• To fi nish out the heater, follow the instructions found in

Section 6.

• To complete heater installation, see Section 5.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 9

B. As an Insert

Pre-installation Preparation

This insert and its components are tested and safe when installed in accordance with this manual. Report to your dealer any parts damaged in shipment, particularly the condition of the glass. Do not install any heater with damaged, incomplete or substitute parts.

WARNING

Fire Risk

• Do not install or operate damaged heater.

• Do not modify heater.

• Installation other than as instructed by Hearth & Home

Technologies Inc. is strictly prohibited.

• Do not operate the heater without fully assembling all components.

• Installation and/or use of any component part not approved by Hearth & Home Technologies.

• A retaining method may be needed to secure the heater in place.

• Combustible facing material may be installed over the original combustible or noncombustible facing material on the solid fuel fi replace. The original specifi ed clearances of a factory-built fireplace must be maintained, with the exception of the hearth. Clearances on a masonry fi replace must be maintained at 12 in. from the opening for combustible projections over 1-1/2 in. Clearances for combustible projections under 1-1/2 in. must be maintained per NFPA 211 . Plan the surround size accordingly. A front face must be used with the insert.

• The insert front face is tested and approved with this insert and may cover existing air circulation vents or grilles on the solid fuel fi replace it is installed into. Should the face not cover the entire ventilation grille surface, the grille should be left open.

• The solid fuel fi replace’s fl ue damper must be fully locked in the closed position or removed for installation.

Note: Decorative trim front faces have been tested and approved to cover existing air circulation vents or grills.

Hearth & Home Technologies disclaims any responsibility for, and the warranty and agency listing will be voided by the above actions.

• The chimney must be capped.

• Install the insert without the front face and make all electrical connections.

Installation

• These inserts are designed for installations into solid fuel masonry or factory built noncombustible fi replaces that have been installed in accordance with the national, provincial, state or local building codes.

• You should seal off the area between the termination cap and the top of the existing chimney opening to avoid down drafts, moisture and/or cold air problems.

• Minimum fi replace opening requirements are shown in

Figures 3.1 and 3.2 of this installation manual. The fi rebrick

(refractory) can be removed from a factory built fi replace in order to gain minimum insert opening requirements.

• This insert requires no hearth extensions. Combustible material on the fl oor may be installed up to the insert. Do not obstruct the lower grill of the insert. The original fi replace cannot be returned to solid fuel in this condition.

• The metal fl oor of the solid fuel fi rebox may be removed to facilitate the installation of the insert. The side walls and top structure of the fi rebox may not be altered with the exception of removable baffl es and dampers. The original fi replace cannot be returned to solid fuel in this condition.

• Position, Level and Secure Insert

• Place the heater into position.

• Level the heater from side to side and from front to back. If necessary, use the leveling bolts included in the manual bag. Screw the bolts into the nuts installed in the bottom of the insert (see replacement parts diagram). Turn bolts in until the insert is level.

10

Note: The warning label above, located in the instruction package, must be affi xed to the lower back wall of the existing fi replace prior to installation of the insert.

Note: When the front is installed it will cover the gap between the heater and the framing, cabinet, fi nishing materials or existing fi replace.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

C. Wiring

Model Description

SILH30E-B 26 in. fi replace/insert

Voltage Watts

120 1500

Amps

(120/208/240)

12.5

WARNING

Shock Risk

Improperly grounded outlets could cause electrical shock.

• Always use properly grounded, fused and polarized outlets.

• Always used ground fault protection where required by electrical code.

Note: This heater must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C2.1 as appropriate.

All wiring must be done by a qualifi ed electrician.

Use appropriate wire to meet local and national codes for rated power consumption.

CAUTION

Disconnect remote controls during your extended absence.

This will prevent accidental operation of the heater.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

• A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit trips or fuse blows on a regular basis when the heater is operated. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.

• The heater is wired from the factory with a polarized plug.

No provisions have been made for hardwiring.

• For ease of electrical hook up, you may wish to install the heater near an existing outlet. A 15 amp, 120 volt circuit is required.

• Run the cord out the notch of the front face.

• Before plugging the heater into the wall outlet, make sure the control switch is in the “OFF” position.

• If the cord does not reach the outlet, a No. 16-AWG minimum wire size extension cord rated for a minimum of 1875 watts may be used. Use minimum length and do not coil cord.

• If installing inside a pre-existing fi replace and if permitted by local codes, an electrician may install an outlet box inside the existing fi replace. Place the outlet in the lower back of the fi rebox.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 11

TEMPERATURE

ADJUSTMENT

POTENTIOMETER

ON_BRIGHT

OFF

ON_DIM

SELECTOR

ORANGE

3 PIN

75 WATT

LAMPS

BLK

WHT

BLK

BLK

BLK

RED

BROWN

BLK

BLK

BLK

WHT

RED

RED 2 PIN

FLAME

MOTOR

BLK

WHT

1

2

1 2 3 4

YELLOW 4 PIN

THERMOSTAT

CONTROL MODULE

DIODE

THERMAL

HIGH

LIMIT

WHT

16 Ga

1300 WATT

HEATER

WHT

16 Ga

NC

BLUE

BLK

REMOTE

THERMISTOR

SENSOR

110 VAC

60 HZ

PLUG AC MALE

RED 2 PIN

BLK

.35

AMP AC

BLOWER

MOTOR

1 2 3

ORANGE 3 PIN

Figure 4.1 110V/120V Wiring Diagram

Power Cord

Wire with Ribs

Black

Red

White

Cable

No Connection

Black Wire to Heater

Power Cord

Black Wire

Figure 4.2 110V/120V Wiring Diagram

12

RW RT

Thermistor

Sensor

Brown

Red

Black

Switch

Assembly

Cable

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

5

Accessories

A. Install the Front Face

Install the front face following the instructions packaged with the face.

B. Install other Optional Accessories

Installation of other optional accessories may be done at this time.

The heater is now ready for operation. See Section 7.

WARNING

Shock Risk

Do NOT operate this heater without the front face installed.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 13

6

Finishing

A. Finishing Material C. Mantel

The height that a combustible mantel is fi tted above the heater is dependent on the height of the front selected. Material which is made of or surfaced with wood, compressed paper, plant fi bers, plastics, or any material capable of igniting and burning, whether fl ame proofed or not, plastered or not plastered.

• The minimum height is 1 in. (25 mm) above the front.

• Fronts available for the 26 in. heater:

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

- 28 in. (711 mm) high

Combustible

Finishing

Material

Grilles/

Mesh

3/4 in. - 12 in.

(19 mm - 305 mm)

Figure 6.1 Finishing Materials

B. Finishing Checklist

• Power supply service must be completed prior to fi nishing to avoid reconstruction.

• Grilles and air openings cannot be covered in any circumstances.

Figure 6.2 Mantel Specifi cations

Note: The heater is a zero clearance fi replace and may be fi nished with combustible or noncombustible fi nishing materials.

When using paint or lacquer to fi nish the mantel, they must be heat-resistant to prevent discoloration.

WARNING

Fire Risk

Do NOT obstruct air inlet or outlet grilles.

Do NOT modify grilles.

• Modifying or covering grilles could cause temperature rise and fi re hazard.

Finishing materials must not interfere with:

• Air fl ow through grilles or louvers

• Operation of louvers or doors

Note: Finishing materials are normally installed behind the nailing fl anges or up to the sides of the nailing fl anges.

Allow room for the front to be added and the heater to be anchored.

14 Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

7

Operating Instructions

WARNING WARNING

Fire Risk

• Do not operate heater before reading and understanding operating instructions.

Failure to operate heater properly may cause fi re.

HOT! DO NOT TOUCH.

SEVERE BURNS MAY RESULT.

CLOTHING IGNITION MAY RESULT.

Glass and other surfaces are hot during operation and cool down.

The operating controls are located on the upper right edge of the heater.

A. Main Power Switch

The main power switch is a three-position switch. See Figure 7.1.

• CAREFULLY SUPERVISE children in same room as heater.

• Alert children and adults to hazards of high temperatures.

• Do NOT operate with protective barriers removed.

• Keep clothing, furniture, draperies and other combustibles away.

• Heater “ON” - Lights bright, thermostat active.

• Heater “OFF” - All off.

• Heater “ON” - Lights dim, thermostat active

- When the main power switch is turned “ON”, it provides power to all functions.

- When used in conjunction with the optional remote control, the switch should remain in an “ON” position.

B. Thermostat

• Active only when lights are on.

• The thermostat allows you to adjust the desired room temperature. See Figure 7.1.

- Set at maximum - always on when the room temperature is below 104° F.

- Set at minimum - always off when the room temperature is above 32° F.

Main Power

Switch

CAUTION

O d o r s a n d v a p o r s r e l e a s e d d u r i n g i n i t i a l operation.

• Curing of high temperature paint.

• Open windows for air circulation.

Odors may be irritating to sensitive individuals.

Thermostat

Control

Figure 7.1 General Operating Parts

WARNING

Fire Risk

All electric heaters have hot and arcing or sparking parts inside.

and other fl ammable vapors and liquids clear of heater.

• Do NOT store fl ammable materials close to heater.

• Keep all such liquids well away from the heater while it is in use.

Combustible materials may ignite.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 15

8

Troubleshooting

A. Troubleshooting Guide

Issues

Heater doesn’t turn on with the main switch or remote transmitter.

Possible Causes

1.

Power switch is off.

2.

Circuit breaker is tripped

3.

Heater is unplugged from wall outlet.

4.

Loose wiring.

Heater is on, but no fl ame or low fl ame 1.

The bulbs are burned out intensity.

2.

Loose wiring.

Flames are frozen.

1.

Loose wiring.

2.

Flame element is not attached to the motor.

3.

Motor is defective.

Excessive noise in the lower portion of the heater.

Heater system doesn’t come on.

Fan runs but not heat is put out.

Heater element is on but fan doesn’t run.

The heater system doesn’t turn off.

1.

Flame element isn’t seated properly.

2.

Motor is defective.

1.

2.

Thermostat is set too low.

3.

Heater switch is off.

Heater system is overheated.

4.

Loose wiring.

1.

Loose wiring.

2.

Bad heating element.

1.

Loose wiring.

2.

Fan is defective.

1.

Thermostat is set too low.

Solutions

1. Turn the power switch to the “ON” position.

2. May need to put the heater on a dedicated service or reduce the number of appliances on the circuit.

3. Plug the cord into an outlet.

4. Check all wiring for loose connections.

1. Replace the bulbs.

2. Check all wiring for loose connections.

1. Check all wiring for loose connections.

2. Reattach the fl ame element to the motor.

3. Replace the motor.

1. Reinstall the fl ame element.

2. Replace the motor.

1. Turn the heater switch to the “ON” position.

2. Move the thermostat slide until you hear a “click”.

3. The heater system is protected by a thermal cutout switch. Shut off the switch. Wait fi ve minuites, then turn the heater on.

4. Check all wiring for loose connections.

1. Check all wiring for loose connections.

2. Replace the heater system.

1. Check all wiring for loose connections.

2. Replace the heater system.

1. Move the thermostat slide down until you hear a “click”.

Excessive noise in upper portion of the 1.

Build up of dirt on the fans.

heater.

2.

Heater fan is defective.

Remote control doesn’t work.

1.

Remote is out of range.

2.

Low batteries.

Odor.

The heater may emit a slight, harmless odor when fi rst used. This is a normal condition caused by initial heating of the internal parts and will not occur again.

1. Clean all fans.

2. Replace the heater system.

1. Move remote closer to the heater.

2. Replace the batteries.

16 Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

9

Maintenance and Service

A. Access the Firebox

• Turn the heater off and turn off the circuit breaker.

• Allow the heater to cool before cleaning.

• Remove the front face to access the log area.

Remove the screws from the switch bracket.

Remove by pulling out the bottom of the front and then lifting up

• Replace all parts after cleaning or bulb replacement has been completed.

• Reset the circuit breaker.

B. Clean the Firebox Compartment

Use the brush attachment and gently vacuum the compartment.

C. Clean the Back Acrylic Panel

• The panel is cleaned in the factory during the assembly process. During shipment, installation, handling, etc., the surface may collect dust particles. These can be removed by buffi ng lightly with a clean dry cloth.

• To remove fi ngerprints or other marks, the panel can be cleaned with a damp cloth using a mild soap and water solution. DO NOT USE GLASS CLEANER! IT WILL

DAMAGE THE BACK ACRYLIC PANEL. The panel should be completely dried with a lint free cloth or paper towel.

Hearth

Assembly

D. Replace the Light Bulbs

The light bulbs need to be replaced when the fl ame and/or ember bed is dark on one side. Replace the bulbs with 75 watt halogen bulbs with mini-candelabra base . Do not exceed 75 watts per bulb. Light bulbs can be purchased at a local hardware or lighting store, on-line or by phone. We recommend you use Sylvania model SL58884 or Satco model

S3157.

• Light bulb access is through the hearth assembly. See

Figure 9.1.

• Locate and lift the bent tabs holding the hearth assembly located at each end of the assembly.

• Lift out the hearth assembly.

• Carefully remove the burned out bulb from the light socket.

Place the new bulb in the socket. See Figure 9.2. Follow directions on the light bulb package for handling requirements.

• Reinstall the hearth assembly.

Figure 9.1 - Bulb Access

WARNING

Shock Risk

Burn Risk

Cleaning, performing maintenance or moving this electric heater without disconnecting power and allowing the heater to cool could create a shock or burn hazard.

• Remove plug from outlet or turn off the circuit breaker to the heater.

Bulbs

Sockets

Bulbs

Figure 9.2 - Replacing the Bulbs

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 17

CAUTION

Handle glass assembly with care.

When cleaning glass door:

• Avoid striking, scratching or slamming glass.

• Do NOT use abrasive cleaners.

• Use a hard water deposit glass cleaner on white fi lm.

• Do NOT clean glass when it is hot.

E. Maintenance Task List

Inspect

Glass Doors

Maintenance Tasks

1. Inspect glass panels for cracks. Replace if this condition is present.

2. Confi rm there is no damage to glass or glass frame. Replace as necessary.

3. Clean glass using a non-abrasive cleaner such as Brasso©.

Circulation Compartment 1. Remove any foreign objects.

2. Verify unobstructed air circulation.

18 Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

10

Reference Materials

A. Heater Dimensions

9-1/4 in.

(235 mm)

1/2 in.

(13 mm)

18-5/8 in.

(473 mm)

22-7/8 in.

(581 mm)

22-5/8 in.

(575 mm)

26 in.

(661 mm)

27-5/8 in.

(702 mm)

16 in.

(407 mm)

4-1/4 in.

(108 mm)

1 in.

(26 mm)

1 in.

(26 mm)

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 19

B. Optional Components

Remote Control

SIGNAL

LIGHT

ON/OFF

BUTTONS

ON

OFF

BATTERY

COMPARTMENT

FRONT BACK

RC-ELEC-HTL

Remote Control

Trim Kits

Refractory

Left Right

RF26E (SILH30E-B)

Side Refractory

PBT26EA (SILH30E -B )

SST26EA (SILH30E -B )

PBT = Polished Brass Trim

SST = Stainless Steel Trim

PBT26ER (SILH30E -B )

SST26ER (SILH30E -B )

Cabinets

Several styles of cabinets are available for use with these heaters. See your dealer/distributor for styles and sizes.

20

DFEB2824 DFED2824

Model Description

DFEB2824 Black Front w/Mesh

DFED2824 Deluxe Black Front w/Mesh

DFE4028

DFE4432

Black Front w/Mesh

Black Front w/Mesh

DFED4028

Width Height

28 in.

28 in.

40 in.

40 in.

24 in.

24 in.

28 in.

32 in.

DFED4432

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

C. Service Parts

Service Parts

Exploded Parts Diagram

SILH30E-B

SILH30E-B

Beginning Manufacturing Date: Apr 2005

Ending Manufacturing Date: Active

20

11

19

9

12

13

14

10

17

16

15

6 5

3

4 2

1

18 - Log Set

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 21

Service Parts

Service Parts List

SILH30E-B

# Description of Part

6 Grommet

4 Halogen Light

3 Light Receptacle

11 Top Magnet Assembly

Power Cord

5 Flame Element Kit

1 Motor

20 Hearth Assembly

Ember Bed

19

18

Grate

Log Assembly

13 Refl ective Flame Decal

2 Motor Bracket

12 Heater/Blower Assembly

9 Acrylic Panel

10 Lenticular Lens

14 Leveling Bolts

15 Thermostat Control Assembly

16 Control Board Assembly

17 Switch Assembly

Slide Pot Rubber Boot

Thermostat Wire RBW

Control Switch Wire Assembly

Thermostat

Installation Manual

Glass Retainer - Top

Strain Relief Bushing (switch wires)

Gasket Kit

SILH30E-B

Beginning Manufacturing Date: Apr 2005

Ending Manufacturing Date: Active

SILH30E-B Qty.

25006

33961

33962

4038-109

4030-802

4030-200

4035-860

4038-041

4038-217

4038-880

4038-004

4021-190

4038-009

4038-107

4038-805

4038-810

4038-823

4038-806

4038-108

4038-110

4038-811

4038-111

4038-814

4038-849

4038-896

4038-012

25756

4038-900

1

1

4

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

2

22 Heatilator • SILH30E-B • 4038-896 Rev C • 11/05

D. Limited Warranty

WARRANTY

Hearth & Home Technologies Inc. (HHT) Electric Fireplaces are tested and inspected prior to shipment and are guaranteed from defect to the purchaser of each new product. Any part which proves to be defective in material or workmanship under normal use within one year will be repaired or replaced without charge.* The

Company will not be responsible for any expense incurred for installation, removal from service, or transportation costs. Any such defect should be brought to the attention of the Dealer where the product was purchased and is authorized to repair or replace within the terms of this warranty.

The Company’s only obligation under this warranty will be at its sole option to repair or replace any part proving defective or to refund the purchase price thereof.

The owner/user assumes all other risks, if any, including the risk of any direct, indirect or consequential loss or damage arising out of the use of or inability to use the product.

The warranty will not apply if, in the sole judgement of the Company, damage or failure has resulted from accident, alteration, misuse, abuse, incorrect installation, or operation on an incorrect power source.

The foregoing is in lieu of all other warranties expressed, implied, or statutory, and the Company neither assumes, nor authorizes any person to assume for it any other obligation, or liability in connection with said product.

*Light bulbs are not covered in the warranty.

How to Obtain Service

To obtain service under this warranty you must:

1. Send written notice of the claimed condition to Heatilator Technical Service Department, Hearth & Home

Technologies Inc., 1915 W. Saunders St., Mt. Pleasant, Iowa 52641.

2. Provide proof of purchase, model number, serial number, and manufacturing date code to HHT.

3. Provide HHT reasonable opportunity to investigate the claim, including reasonable opportunity to inspect the

Appliance prior to any repair or replacement work and before the Appliance or any component of the Appliance has been removed from the place of original installation.

4. Obtain HHT’s consent to any warranty work before the work is done.

ADDITIONAL INFORMATION: If you would like information on current Heatilator products or want to locate a dealer in your area, call 1-800-927-6841.

©2003 Heatilator® is a Registered Trademark of Hearth & Home Technologies Inc.

Heatilator • SILH30E-B • 4038-896 Rev C • 11/05 23

E. Contact Information

Hearth & Home Technologies Inc.

1915 W. Saunders Street

Mt. Pleasant, Iowa 52641 www.heatilator.com

Please contact your Heatilator dealer with any questions or concerns. For the number of your nearest Heatilator dealer, please call 1-800-927-6841.

– NOTES –

CAUTION

DO NOT DISCARD THIS MANUAL

operating understand a n d m a i n t e n a n c e a n d f o l l o w t h e s e instructions included.

instructions for safe i n s t a l l a t i o n a n d operation.

party responsible for use and operation.

DO

DISCARD

NOT

This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322,

4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495,

5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112,

5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226,

6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942,

6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884,

D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.

24 Heatilator • SILH30E-B • 4038-896 Rev C • 11/05