Boca Flasher HPNFC-RT Installation Manual
Boca Flasher HPNFC-RT is a versatile line voltage fixture designed for both indoor and outdoor use. Its durable construction and weather-resistant anodized aluminum housing make it suitable for various applications, including wet locations. With its simple installation process and twist-lock or rigid connections, you can easily create continuous runs of light. The HPNFC-RT offers energy efficiency with low power consumption, making it an ideal choice for projects where cost-effectiveness is a priority.
Advertisement
Advertisement
Installation Manual
HPNFC-RT
WARNING: DO NOT LIFT FIXTURE BY CABLES.
Do not attempt to install or use the HPNFC-RT
fixture without reading the installation instructions and safety labels completely.
This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/or putting undue pressure on the cable connections will not be covered under the warranty!
FAILURE TO ADHERE TO THESE INSTRUCTIONS COULD RESULT IN SERIOUS
INJURY OR PROPERTY DAMAGE.
DO NOT MODIFY, ALTER OR ATTEMPT TO SERVICE THE HPNFC-RT
DOING SO WILL VOID THE WARRANTY.
Installation Instructions
HPNFC-RT
Indoor/Outdoor Shallow Profile Line Voltage
Introduction:
The Boca HPNFC-RT is a line voltage fixture that eliminates the need for secondary transformers, making installation contractor friendly. The housing is a clear anodized aluminum with a durable finish making it weather and abrasion resistant. It is UL Listed for dry, damp or wet location (model dependent). See layout drawings for model provided.
Maintenance:
CLEANING Dry and Damp (IP65) Rated Fixtures: To clean surface use a soft damp cloth.
Wet (IP68) Rated Fixtures: To clean surface use a soft cloth with mild soap and water.
STORAGE Store in a dry, well-ventilated area when product is not in use. Keep the electrical cord away from heated surfaces when in use or not in use. If cord shows signs of damage do not use, return product to manufacturer.
Electrical Specifications:
1. Input Voltage: 90-120VAC, 230-277VAC
2. Total linear ft per 20A breaker: HO8 = 175’
Total linear ft per 20A breaker: HO6 = 200’
Total linear ft per 15A breaker: HO8 = 130’
Total linear ft per 15A breaker: HO6 = 150’
3. Input Current: HO8 = 114mA RMS per linear ft.
Input Current: HO6 = 95mA RMS per linear ft.
Fixtures must be installed by a qualified and licensed electrician in accordance with all national, state and local electrical codes and regulations.
If any part of this manual does not meet the necessary codes and regulations, contact the factory for more information before attempting to install.
IP65
DAMP LISTING
IP68
WET LISTING
Model Dependent
Max temp: 55C
Min. temp: -40C
Turn Power Off At Circuit Breaker
Before Beginning Installation!
INCLUDED IN THIS PACKAGE:
1 HPNFC-RT Fixtures
(In lengths shown on job specific drawings)
2 Mounting Brackets
(2 brackets per fixture)
Fixed
OR
Swivel
3 Job Specific Drawings
Power cord length is
6.5ft per UL standard
3" Arc
OR
PAGE 2 OF 8
6" Arc
Installation Instructions
HPNFC-RT
CAUTION: Before installing any type of clip (fixed, swivel or arc) onto the mounting surface determine if the fixtures have rigid or twist lock connections at each end (examples of the rigid and twist lock types are shown in section 4).
Installation of clips for light fixtures with RIGID Connections
1. Light fixtures that have rigid connections on each end must be installed in the same plane and must also be in a straight alignment.
Using a chalk line or laser, mark a line on the flat surface where the clips are to be mounted. Align each clip to the chalk line using the same reference point on each clip (clip edge or hole) and space the clips according to the length of each fixture (see figure A).
Clip placement: Boca Flasher recommends clips to be installed 1.5” from end cap.
2. Snap in the first light fixture into the clips (see section 2, installing fixtures into clips). Snap the 2nd. light fixture into adjacent clips ensuring that the connections will mate (male to female, see figure B).
3. Slide the second light fixture into the first light fixture until fully seated. ( see figure B & 4d).
4. Install #2 lock screw (see figure 4e).
THIS CAN CAUSE PERMANENT DAMAGE TO FIXTURE CONNECTION AND OPERATION. ( see figure B).
6. Continue this process until all light fixtures are installed according to the job specific layout drawings.
7. Connect fixtures to power per section 5 and 6.
FIGURE A:
CLIP ALIGNMENT
PAGE 3 OF 8
Installation Instructions
HPNFC-RT
1. INSTALL CLIPS INTO SUBSTRATE
Fixed Clips Swivel Clips
1b
1a 1a
1b Locking Swivel Bracket:
1. Boca Flasher
recommends using an
off set Philips screw
driver with a #2 bit.
2. Screwdriver should be
capable of making
90° bend.
3” Arc and 6” Arc Bracket Installation
1a
1b
Screw Information:
1. Screws not provided by Boca Flasher.
2. Boca Flasher recommends wide
washer flat head Philips #8 screw
(not to exceed .418” in diameter).
3. Length of screw will vary depending
on mounting surface.
4. For outdoor installations, installer
should use a screw with
weatherproof coating.
2. INSTALL FIXTURE INTO CLIPS
2a Place the notch on the clip into the first notch of the fixture.
2b Fixture will pivot on notch as it is pushed down.
2c
Clip will securely snap into place.
2d
If using the Swivel Clip or Arc Bracket loosen the screw where the clip and swivel bracket meet to adjust angle of the fixture.
▶ snap!
▶
PAGE 4 OF 8
Installation Instructions
HPNFC-RT
3. CLIP POSITIONING
3a
Fixed Mounting Clip
3b Swivel Mounting Clip
FIXTURE LENGTH
FIXTURE LENGTH
3c
Arc Mounting Clip
FIXTURE LENGTH
FIXTURE LENGTH
FIXTURE LENGTH
FIXTURE LENGTH
4. CONNECT DMX CABLES TOGETHER
AS SHOWN ON JOB SPECIFIC DRAW-
4a
Rotate fixture to see bottom and note each label.
4b Cross-reference with Job
Specific Drawing.
4c
▶
▶
◀
BF-01 ▶
Labels on fixtures correspond with nomenclatures on drawings.
▶
HPNFC-HO
IMPORTANT NOTE:
Not screwing fixtures together represents an incomplete install and voids the warranty. If any fixtures are damaged as a result of improper installation.
1
4d
Push together until you hear a “Click” then twist until secure.
2
Click
▶
PAGE 5 OF 8
2
Installation Instructions
HPNFC-RT
Installation of clips for light fixtures with TWIST LOCK Connections
1. Light fixtures that have twist lock connections on each end may be installed in areas where the surface plane may be at slightly different levels between light fixtures. Also, the light fixtures do not have to be in straight alignment and can be laid out to different angles and patterns.
2. Using a chalk line or laser mark a line on the flat surface where the 2 clips for the 1st. fixture are to be mounted. (See Figure: A)
3. Snap in the first light fixture into the clips (see section 2 installing fixtures into clips).
4. Using a chalk line or laser mark a line on the flat surface where the 2 clips for the 2nd fixture are to be mounted, this fixture can be placed on a slightly different plane as long as the cord between the 2 fixtures is long enough. Also, this fixture can be placed at a different angle than the first fixture (see figure 4).
5. Snap in the 2nd light fixture into the clips (see section 2 installing fixtures into clips).
6. Continue this process until all light fixtures are installed according to the job specific layout drawings.
7. Connect fixtures to power per section 5 and 6.
Light fixtures can be mounted at various angles and levels.
4. CONNECT FIXTURES TOGETHER
TWIST LOCK CONNECTION
4a
See above for information on determining layout.
4c Push together and then twist until completely connected and sealed if outdoors.
4b
Connect Male and Female twist lock cables in order shown on job specific drawings.
Add tape to twist locks.
Place thumb over tape at starting point and PULL around connector area until tape overlaps itself.
PAGE 6 OF 8
Installation Instructions
HPNFC-RT
4. CONNECT FIXTURES TO POWER
Recommended Install - Option 1
12V
CLASS-1
120/277V
NEMA 4R
12V - CLASS-1
12V - CLASS 2 (8 outputs)
4. CONNECT FIXTURES TO POWER
Recommended Install - Option 2
12V
CLASS-1
NEMA 4R
120/277V
12V - CLASS-1
5. CONNECT TO A DIMMING SYSTEM
12V - CLASS 2 (8 outputs)
120/277V
12V
CLASS-1
12V - CLASS-1
NEMA 4R
12V - CLASS 2 (8 outputs)
PAGE 7 OF 8
Installation Instructions
HPNFC-RT
7. REMOVING FIXTURES FROM CLIPS
IF NECESSARY
7a Slide a flat head screwdriver in between the clip and fixture.
7b While holding the fixture with your other hand, pull back on screwdriver to release from notch.
7c Once released from one notch, fixture can be fully removed.
IMPORTANT SAFETY REMINDERS:
1. DANGER:
To reduce the risk electric shock, always unplug the HPNFC-RT from electrical outlet before cleaning. Cut breaker
if outlet is not available.
2. To reduce the risk of burns, fire, electric shock or injury to persons:
• Use the HPNFC-RT only for its intended use as described in these instructions.
• Do not use attachments not recommended by Boca Flasher.
• Never operate the HPNFC-RT if it has a damaged cord, cable or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. If the seal appears to be damaged/broken/torn return the fixture
to a service center for examination or repair.
• Keep cables away from heated surfaces
• Never drop or insert any object into any opening.
• Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
3. WARNING:
Do not attempt to install or use the HPNFC-RT without reading the installation instructions and safety labels.
Failure to adhere to these instructions could result in serious injury or property damage.
4. Do not modify, alter or attempt to service the HPNFC-RT:
Doing so will void the warranty.
5. There are no serviceable parts within the HPNFC-RT:
Please contact your local representative if issues arise on site during or after installation.
6. Do not use sharp tools near or on the fixture lens:
Doing so will result in property damage and void the warranty.
Boca Flasher, Inc.
508 S. Military Trail n Deerfield Beach, Florida n 33442 USA
Phone: 561-989-5338 n Fax: 561-982-8323 www.bocaflasher.com
We are constantly improving our fixtures and reserve the right to change options and specifications. Additional information & details at www.
bocaflasher.com. For specific requirements, contact your Boca Flasher sales representative. Boca Flasher, Inc. 552 NW 77th Street Boca Raton,
Florida 33487 USA Phone: 561.989.5338 Fax: 561.982.8323 © 2015 Boca Flasher, Inc. All rights reserved. All names and trademarks are property of their respective owners. REV 07-2017
IP65
DAMP LISTING
IP68
WET LISTING
Advertisement