GE CVW93643PDS Café™ 36" Commercial Hood Installation instructions


Add to my manuals
28 Pages

advertisement

GE CVW93643PDS Café™ 36

TM

Owner’s Manual & Installation Instructions

Vented Range Hoods

With QuietBoost™ Blower

Models: CVW9304 and CVW9364

Contents

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Using the Hood

Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Chef Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Wi-Fi Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Care And Cleaning

Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . .9

Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

Consumer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

Write the model and serial numbers here:

Model # _______________________________

Serial # _______________________________

You can find them on a label on the inside of the hood.

Español

Para consultar una version en español de este manual de instrucciones, visite nuestro sitio de internet cafeappliances.com

.

49-2000706 Rev. 3 05-21 GEA

2

THANK YOU FOR MAKING CAFÉ A PART OF YOUR HOME.

We take pride in the craftsmanship, innovation and design that goes into every Café product, and we think you will too. Among other things, registration of your appliance ensures that we can deliver important product information and warranty details when you need them.

Register your Café appliance now online. Helpful websites are available in the Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration card included in the packing material.

TM

49-2000706 Rev. 3

WARNING

TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

C. Do not use this unit with any solid-state speed control device.

D. This unit must be grounded.

CAUTION

FOR GENERAL VENTILATING USE

ONLY. DO NOT USE TO EXHAUST HAZARDOUS

OR EXPLOSIVE MATERIALS AND VAPORS.

CAUTION

To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

WARNING

TO REDUCE THE RISK OF INJURY

TO PERSONS IN THE EVENT OF A RANGE TOP

GREASE FIRE, OBSERVE THE FOLLOWING*:

A. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE

CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL

THE FIRE DEPARTMENT.

B. NEVER PICK UP A FLAMING PAN—You may be burned.

C. DO NOT USE WATER, including wet dishcloths or towels—a violent steam explosion will result.

D. Use an extinguisher ONLY if:

1. You know you have a Class ABC extinguisher, and you already know how to operate it.

2. The fire is small and contained in the area where it started.

3. The fire department is being called.

4. You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

WARNING

TO REDUCE THE RISK OF A

RANGE TOP GREASE FIRE:

A. Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B. Always turn hood ON when cooking on high heat or when flambéing food (i.e. Crepes Suzette, Cherries

Jubilee, Peppercorn Beef Flambé).

C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

D. Use proper pan size. Always use cookware appropriate for the size of the surface element.

49-2000706 Rev. 3

READ AND SAVE THESE INSTRUCTIONS

3

WARNING

TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting.

Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection

Association (NFPA), the American Society for

Heating, Refrigeration and Air Conditioning

Engineers (ASHRAE) and the local code authorities.

When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit cafeappliances.com

for available makeup air solutions.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.

E. Turn off breaker to adjacent rooms while working.

WARNING

TO REDUCE THE RISK OF FIRE,

USE ONLY METAL DUCTWORK.

Do not attempt to repair or replace any part of your hood unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician.

How to Remove Protective Shipping Film and Packaging Tape

Carefully grasp a corner of the protective shipping film with your fingers and slowly peel it from the appliance surface. Do not use any sharp items to remove the film.

Remove all of the film before using the appliance for the first time.

To assure no damage is done to the finish of the product, the safest way to remove the adhesive from packaging tape on new appliances is an application of a household liquid dishwashing detergent. Apply with a soft cloth and allow to soak.

NOTE: The adhesive must be removed from all parts.

4

READ AND SAVE THESE INSTRUCTIONS

49-2000706 Rev. 3

Controls

1 2 3

Fan Settings

4

Off

Delay O

Hold 3 Sec

Low

WiFi

Pairing

Med High

Boost

Hold 3 Sec

Light WiFi

7

1. Rangehood Control Panel:

The control panel is located under the front edge of the canopy. The position and function of each control button are noted below.

2. Fan On/Off:

On/Off switch for the fan. The fan can be operated by pressing any of the fan setting buttons. Hold Power for 3 seconds to activate Delay

Off feature, which automatically turns the fan off after

15 minutes. Low, Med and High buttons LEDs will rolling blink to indicate Delay Off feature is activated.

3. Fan Settings:

Speed control for fan. Fan speed is powered by QuietBoost™ Technology.

This unique technology is designed to minimize ventilation noise and enhance motor efficiency for a peacefully-quiet, odor-free kitchen. Press the button

Low for LOW speed, Med for MEDIUM speed, and

High for HIGH speed. Hold down the High button for 3 seconds to activate the Boost speed that will run for 15 minutes. High button LED will blink on/off to indicate Boost feature is activated.

5 6

4. Light:

Off/On/Night Light switch for the LED lights.

Press the Light button to turn the lights on, again to set the lights to night light setting, and again to turn the lights off.

5. Chef Connect:

This is a Bluetooth ® pairing feature for use with other compatible Chef Connect enabled products on a cooktop or range. When the device is paired, the default sync settings will be activated upon receiving a command from the range or cooktop. To change the default sync setting, refer to the Chef

Connect section.

To pair devices, hold down the Light button for 3 seconds. To turn it back off, hold the button down for another 3 seconds. See the Chef Connect section for more details.

6. IR Sensor:

Remote control receiver when used with remote control kit.

7. Wi-Fi:

Hold down the Low button for 3 seconds to initiate the Wi-Fi connection. The Wi-Fi indicator light turns on when connected, see the Wi-Fi

Connect section for details.

Chef Connect

Chef Connect Operation Bluetooth

®

Connection

To pair with another device: Default Sync Settings:

To start the pairing process on the hood, press and hold the Light button for 3 seconds. The backlight for all the icons will flash until the hood is paired with the range or other device. If the pairing is successful, the backlights of all buttons will flash simultaneously three times and then turn off. The hood lights and fan default sync setting will be activated.

It will time out after 2 minutes if the pairing is not completed, after which the pairing sequence will need to be restarted.

To cancel pairing:

To cancel the pairing, hold the Light button down for 3 seconds and then turn off the hood.

The factory default setting for the light will be the brightest.

The factory default setting for the fan sync will be OFF.

The user can change the Default Sync Settings by pressing and holding the Med button for 3 seconds.

This will enter the Default Settings Mode. Once in this mode, the backlights for all buttons will blink on/ off indefinitely and the fan and light will switch to the current Default Sync Setting, so the user knows what the current default value is. At this time, set the light and fan to the desired default levels. Once the user is satisfied with the selection, press and hold the Power button for 3 seconds. This will exit this mode. At that time the backlights will stop blinking and the state of the fan and light will change back to their prior state before entering the Default Settings Mode.

49-2000706 Rev. 3

5

Wi-Fi Connect

Connecting your Wi-Fi Connect Enabled hood (on some models)

Your Café hood is designed to provide you with two-way communication between your appliance and smart device. By using the Café Appliances Wi-Fi Connect features, you will be able to control essential hood operations such as fan speed, light functions, delay off and filter notification using your smartphone or tablet.

Connect your Café hood

1. On your smart phone or tablet visit caféppliances.

com/connect to learn more about connected appliance features and to download the appropriate app.

2. Follow the app onscreen instructions to connect your

Café hood.

This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions: (1)

This device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that may cause undesired operation.

What you will need

Your Café hood uses your existing home Wi-Fi network to communicate between the appliance and your smart device. In order to setup your Café, you will need to gather some information:

1. Each Café hood has a connected appliance information label that includes an Appliance Network

Name and Password. These are the two important details that you will need to connect to the appliance.

The label is located on the side of the unit behind the filters.

3. Once the process is complete, the indicator light located on your Café hood display will stay on solid and the app will confirm you are connected.

4. If the indicator light does not turn on or is blinking, follow the instructions on the app to reconnect. If issues continue please visit caféppliances.com/ connect regarding hood wireless connectivity.

To connect additional smart devices, repeat steps 1 and 2.

Note that any changes or modifications to the remote enable device installed on this hood that are not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

Enhanced Wi-Fi Features

Once your product is connected to Wi-Fi, you have access to enhanced features via phone app.

Connected Appliance Information

FCC ID: ZKJ-WCATA005 Network: ************

Delay Off Timer: This feature allows the user to adjust delay off time from 1 minute to 15 minutes. The default delay off time is 15 minutes.

IC: 10229A-WCATA001 Password: **********

MAC ID: ************

Sample Label

Boost Timer: This feature allows the user to adjust the boost time from 1 minute to 15 minutes. The default boost time is 15 minutes

2. Have your smart phone or tablet ready with the ability to access the internet and download apps.

3. You will need to know the password of your home

Wi-Fi router. Have this password ready while you are setting up your Café hood.

Night Light Timer: This feature allows the user to set time for the night light to turn on and off automatically.

Grease/Charcoal Filter Notifications: This feature sends a regular reminder to the user to clean their grease filters, and/or to replace their charcoal filter, if the hood is setup in recirculation mode.

6

* Compatible Apple or Android devices and home Wi-Fi network required.

49-2000706 Rev. 3

Filters

Be sure the circuit breaker is off and all surfaces are cool before cleaning or servicing any part of the vent hood.

The baffle filters and drip trays are dishwasher safe and should be cleaned every month, depending on the usage of the hood

Grease Drip Tray

To install:

Place and seat the drip trays into the designated hood track. Slide them left or right until all trays are side-byside in place in the track.

To remove:

Carefully, use the grease tray lip to lift the tray upwards and out. The tray will be free of the designated hood track.

To clean:

Swish the drip tray in hot soapy water and rinse in clean water or wash it in the dishwasher. Do not use abrasive cleaners.

NOTE: Some discoloration of the grease drip tray may occur in the dishwasher.

Drip Tray Replacement

Baffle Grease Filter

The baffle filters channel grease released by foods on the cooktop into the drip trays. The baffle filters also help prevent flaming foods on the cooktop from damaging the inside of the hood.

The baffle filters must ALWAYS be in place when the hood is in use.

To install:

Insert the top of the baffle (side without knob) into the track behind the control panel. Push knob side into the back, twist to lock into place.

To remove:

Pull and twist knob and slowly pull filter down. Hold with other hand and pull filter away from the track behind the control panel.

It is important for baffle filters to be placed correctly to channel grease to the drip trays and avoid grease accumulation in the baffles.

To clean:

Swish the filter in hot soapy water and rinse in clean water or wash it in the dishwasher. Do not use abrasive cleansers.

2

NOTE: Some discoloration of the filter may occur in the dishwasher.

To clean hard to reach areas of the filter, use a soft brush.

1

Baffle Replacement

49-2000706 Rev. 3

7

8

Filters (Cont.)

Charcoal Filter (for recirculation installation on select models only)

NOTE: DO NOT rinse, or put charcoal filter in an automatic dishwasher.

4. Clip the charcoal filter in until it is locked

5. Repeat with second filter on the other side of the motor.

The charcoal filter is NOT included with the unit.

Order Charcoal Filter UXCF91. It cannot be cleaned; it must be replaced. It is recommended that the charcoal filter be replaced every 6 months or if it is noticeably dirty or discolored.

6. Reattach the metal filters. See Filters section.

To Remove

1. Remove grease filters-See Filters section

2. Unclip the charcoal filter by pressing the release clip.

To reduce the risk of fire and shock, when used in recirculation mode, use only charcoal filter UXCF91.

To inquire about purchasing replacement charcoal filters or to find the location of a dealer nearest you, please call our toll-free number:

3. Carefully remove charcoal filter from tab.

Charcoal Filter Mount

National Parts Center 800.626.2002

To Install

1. Remove the grease filters. See Filters section.

2. Install the charcoal filter mounts to either side of the motor using three screws per side.

3. Insert the tab on the charcoal filter into the triangular slot on the mount.

Surfaces

Painted Surfaces

Do not use a steel wool pads or other abrasive cleaners; they will scratch the surface.

Clean grease-laden surfaces of the hood frequently. To clean the hood surface, use a hot, damp cloth with a mild detergent suitable for painted surfaces. About one tablespoon of ammonia may be added to the water. Use a clean, hot, damp cloth to remove soap. Dry with a dry, clean cloth.

NOTE: When cleaning, take care not to come in contact with filters and other surfaces.

CAUTION

When cleaning the hood surfaces, be certain that you do not touch the light with moist hands or cloth. A warm or hot light may break if touched with a moist surface. Always let the light cool completely before cleaning around it.

Lights

To change the LED lamps, schedule a service appointment. See Consumer Support page in the front of this manual for a list of websites and contact information.

49-2000706 Rev. 3

Installation Instructions

If you have questions, visit us at cafeappliances.com or visit our website at: cafeappliances.ca.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT

— Save these instructions for local inspector’s use.

IMPORTANT

— Observe all governing codes and ordinances.

■ Note to Installer – Be sure to leave these instructions with the Consumer.

■ Note to Consumer – Keep these instructions for future reference.

■ Skill level – Installation of this vent hood requires basic mechanical and electrical skills.

■ Completion time – Approximately 1 to 3 hours

■ Proper installation is the responsibility of the installer.

■ Product failure due to improper installation is not covered under the Warranty.

CAUTION

Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product, TWO PEOPLE ARE

REQUIRED FOR PROPER INSTALLATION.

WARNING

TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting.

Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection

Association (NFPA), the American Society for

Heating, Refrigeration and Air Conditioning

Engineers (ASHRAE) and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.

E. Turn off breaker to adjacent rooms while working.

WARNING

TO REDUCE THE RISK OF FIRE,

USE ONLY METAL DUCT WORK.

WARNING

Disconnect all electrical power at the main circuit breaker or fuse box before installing.

FOR YOUR SAFETY

WARNING

Before beginning the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

49-2000706 Rev. 3

9

10

Installation Preparation

PRODUCT DIMENSIONS

12-1/4”

18”

21”

30” Models

Requires a 30” opening.

12-1/4”

18”

30”

21”

36” Models

Requires a 36” opening.

36”

49-2000706 Rev. 3

TOOLS AND MATERIALS

REQUIRED (NOT SUPPLIED)

Pencil and tape measure

Level

Electric drill with #2 Phillips with 1/8" and 5/16" drill bits

UL listed wire nuts

Wire Nuts

8” round duct

Installation Preparation

Safety glasses

Phillips screwdriver with at least 6" shank

Wire cutter/stripper

Aluminized duct tape

Strain relief for junction box, 1” diameter knockout

Strain Relief I

PLAN THE INSTALLATION

CAUTION

To reduce risk of fire and to properly exhaust air, be sure to duct the air outside.

Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

PARTS SUPPLIED FOR INSTALLATION

■ 1 Hardware Package

■ 1 Literature Package

■ 1 Installation Template

PARTS NEEDED FOR INSTALLATION

■ 1 Strain Relief

■ 1 Wall or Roof Cap (for vented installation only)

■ All Metal Ductwork

WARNING

PERSONAL INJURY HAZARD

Because of the weight and size of the rangehood canopy. It is recommended that 2 people are used to install the range hood. Failure to properly lift rangehood could result in damage to the product or personal injury.

NOTE: Before making any cuts or holes for installation, determine which venting method will be used and carefully calculate all measurements.

Gloves

Needed for back venting only

12" round duct

8”x12” to 12” round duct transition

REMOVE THE PACKAGING

CAUTION sharp edges.

Wear gloves to protect against

■ Remove the hood body.

■ Remove the hardware bag, literature package and other boxed parts.

■ Remove and properly discard the protective plastic wrapping and other packaging materials.

49-2000706 Rev. 3

11

12

Installation Preparation

PARTS PROVIDED

Locate the parts packed with the hood.

HARDWARE PACKAGE

Locate and check contents.

761Dia28

Hood Body

2 Baffle Filters

(3 with 36” models)

Top Damper

Motor

Grease Drip Trays

Metal Installation Bracket

A B

(QTY: 4) 2.9mm x 6mm

PZ screws. Used to attach the damper

(QTY: 4) 8 x 1-3/4 AB screw. Used to mount the installation bar. Use 1/8" drill for pilot hole.

D

(QTY: 4) M4 screws.

Used to mount motor

C

(QTY: 2) 3/16” dry wall anchors with screws. Used for hood bottom mounting screw holes. Use 5/16" drill for pilot hole.

49-2000706 Rev. 3

Installation Preparation

DUCT COVER REQUIREMENTS

Duct cover kits must be purchased separately.

We recommend that the vent hood and duct cover

(if used) be on site before final framing and wall finishing. This will help to accurately locate studs, ductwork and electrical service.

INSTALLATION DIMENSIONS

The hood duct covers can be adjusted for different ceiling heights depending on the distance between the bottom of the hood and the cooktop (distance

X). See Installation Height Table on the next page.

5" min

27" max

Upper Duct

Cover

19-1/2” Lower Duct Cover Y

18”

• Duct cover accessory comes with a lower and upper duct cover and installation hardware.

• The installation hardware includes mounting brackets to secure duct covers to the wall.

• For vented installations, recirculation holes can be hidden by installing the upper duct cover upside down.

• See table below for duct cover kit part numbers based on finish.

Model #

30” & 36"

Model (Matte

Black)

30” & 36"

Model (Matte

White)

Duct Cover Kit #

CX8DC9SPDS

CX10DC9SPDS

CX12DC9SPDS

CX8DC9SPWM

CX10DC9SPWM

CX12DC9SPWM

Max Ceiling

Installation

8’ 4”

11’ 1/4”

13’ 4”

8’ 4”

11’ 1/4”

13’ 4”

NOTE: Duct Cover Kits CX8DC9SPDS and

CX8DC9SPWM only support vented installation mode.

X

Required Min & Recommended Max Ceiling Height

Examples for 10’ Duct Cover Kit (Vented)

Electric Gas

X = 24”

Y = Min 8’ 2”

Max 9’ 10”

X = 30”

Y = Min 8’ 10”

Max 10’ 6”

X = 36”

Y = Min 9’ 4”

Max 11’ 0"

X = Distance from hood to cooktop. (Varies depending on the installation) Required 24” minimum over electric range or 30” minimum over gas range. The recommended maximum is 36".

36” or

38"

Typical Range

NOTE: 36" for typical electric range and 38" for gas range.

49-2000706 Rev. 3

13

14

9’ 6”

9’ 7”

9’ 8”

9’ 9”

9’ 10”

9’ 11”

10’ 0”

10’ 1”

10’ 2”

10’ 3”

10’ 4”

10’ 5”

10’ 6”

10’ 7”

10’ 8”

10’ 9”

10’ 10”

10’ 11”

11’

11’ 1”

11’ 2”

11’ 3”

11’ 4”

Installation Preparation

7’ 7”

7’ 8”

7’ 9”

7’ 10”

7’ 11”

8’ 0”

8’ 1”

8’ 2”

8’ 3”

8’ 4”

INSTALLATION HEIGHT TABLE

CX8DC9SPDS OR

CX8DC9SPWM

CX10DC9SPDS OR CX10DC9SPWM

High Ceiling Duct Cover up to 10 ft.

Ceiling Duct Cover Kit up to 8ft.

Installation over Gas

Range

Installation over Electric

Range

Ceiling

Height

(ft./in.)

7’ 0”

Installation over Gas

Range

Vented

Installation

Height

Installation over Electric

Range

Vented

Installation

Height

24

Ceiling

Height

(ft./in.)

8’ 2”

Recirc

Installation

Height

Vented

Installation

Height

(Recirc holes hidden)

Recirc

Installation

Height

Vented

Installation

Height

(Recirc holes hidden

24

7’ 1”

24-25

8’ 3” 24-25

7’ 2”

24-26

8’ 4” 24-26

7’ 3”

25-27

8’ 5” 24-27

7’ 4”

26-28

8’ 6” 24-28

7’ 5”

27-29

8’ 7” 24 24-29

7’ 6”

28-30

8’ 8” 24-25 24-30

30

30-31

30-32

31-33

32-34

33-35

34-36

35-36

36

29-31

30-32

31-33

32-34

33-35

34-36

35-36

36

8’ 9”

8’ 10”

8’ 11”

9’ 0”

9’ 1”

9’ 2”

9’ 3”

9’ 4”

9’ 5”

30

30-31

30-32

30

30-31

30-32

30-33

30-34

30-35

24-26

24-27

24-28

24-29

24-30

24-31

24-32

24-33

24-34

24-31

24-32

24-33

24-34

24-35

30-33

30-34

30-35

30-36

31-36

32-36

33-36

34-36

35-36

36

30-36

31-36

32-36

33-36

34-36

35-36

36

24-35

24-36

25-36

26-36

27-36

28-36

29-36

30-36

31-36

32-36

33-36

34-36

35-36

36

24-36

25-36

26-36

27-36

28-36

29-36

30-36

31-36

32-36

33-36

34-36

35-36

36

Ceiling

Height

(ft./in.)

9’ 1”

9’ 2”

9’ 3”

9’ 4”

9’ 5”

9’ 6”

9’ 7”

12’ 8”

12’ 9”

12’ 10”

12’ 11”

13

13’ 1”

13’ 2”

12’ 2”

12’ 3”

12’ 4”

12’ 5”

12’ 6”

12’ 7”

11’ 8”

11’ 9”

11’ 10”

11’ 11”

12’

12’ 1”

11’ 2”

11’ 3”

11’ 4”

11’ 5”

11’ 6”

11’ 7”

10’ 8”

10’ 9”

10’ 10”

10’ 11”

11’

11’ 1”

10’ 2”

10’ 3”

10’ 4”

10’ 5”

10’ 6”

10’ 7”

9’ 8”

9’ 9”

9’ 10”

9’ 11”

10’ 0”

10’ 1” 30

30-31

30-32

30-33

30-34

30-35

30-36

31-36

32-36

33-36

34-36

35-36

36

CX12DC9SPDS OR CX12DC9SPWM

High Ceiling Duct Cover up to 12 ft.

Installation over Gas

Range

Recirc

Installation

Height

Vented

Installation

Height

(Recirc holes hidden)

30

30-31

30-32

30-33

30-34

30-35

30-36

31-36

32-36

33-36

34-36

35-36

36

Installation over Electric

Range

Recirc

Installation

Height

Vented

Installation

Height (Recirc holes hidden

24

24-25

24-26

24-27

24-28

24-29

24-30

24-31

24-32

24-33

24-34

24-35

24-36

25-36

26-36

27-36

28-36

29-36

30-36

31-36

32-36

33-36

34-36

35-36

36

24

24-25

24-26

24-27

24-28

24-29

24-30

24-31

24-32

24-33

24-34

24-35

24-36

25-36

26-36

27-36

28-36

29-36

30-36

31-36

32-36

33-36

34-36

35-36

36

49-2000706 Rev. 3

Installation Preparation

ADVANCE PLANNING

Duct Install Planning

■ This hood is designed to be vented vertically through the ceiling with a 8” round duct or, horizontally through a wall with an 8”x12” duct transition and 12” round duct.

■ Use metal ductwork only.

■ Plan the route for venting exhaust to the outdoors.

To maximize the ventilation performance of the vent system:

1. Minimize the duct run length and number of transitions and elbows.

2. Maintain a constant duct size.

3. Seal all joints with duct tape to prevent any leaks.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduces performance.

■ Maximum equivalent duct length for 100 CFM: 150 foot for vent hoods.

■ Install a wall cap or roof cap with damper at the exterior opening. Purchase the wall or roof cap and any transition and length of duct needed in advance.

■ When applicable, install any makeup

(replacement) air system in accordance with local building code requirements. 8” round duct makeup air kit JXMUA8 can be purchased from cafeappliances.com

.

Vent system can terminate either through the roof or the wall.

Add Insulation and/or Caulk

Roof Cap

Round Duct

POWER SUPPLY

IMPORTANT – (Please read carefully)

WARNING

FOR PERSONAL SAFETY, THIS APPLIANCE

MUST BE PROPERLY GROUNDED.

Remove house fuse or open circuit breaker before beginning installation.

Do not use an extension cord or adapter plug with this appliance. Follow National Electrical Codes or prevailing local codes and ordinances.

Electrical supply

These vent hoods must be supplied with 120V,

60Hz, and connected to a properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.

■ Wiring must be 2 wire with ground.

■ If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.

■ Route house wiring as close to the installation location as possible in the ceiling or wall.

■ Connect the wiring to the house wiring in accordance with local codes.

Grounding instructions

The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood.

WARNING

The improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded.

Top Venting Setup

Add tape to joint

Hood

Add Insulation and/or Caulk

Wall Cap

Add Tape to

Joint

49-2000706 Rev. 3

15

16

Installation Preparation

NEW CONSTRUCTION, PRE-PLANNING, OR REMODELING

NOTE: For existing instruction, skip to the next section.

FOR TOP VENTING

■ For ducted installation through the top, the 8” diameter hole for the duct in the ceiling must be centered 6-1/4” away from the finished rear wall in the installation space.

FOR BACK VENTING

■ For ducted installation through the back, the 10-1/2" x 13-1/4" cut out for the duct in the wall must be centered in the installaton space, left to right and located 3-3/4” above intended install height from bottom of the hood.

■ The hood junction box knockout is located 10-1/2” to the left from center of the hood. Ensure enough wire length is available to make electrical connection.

6-1/4”

3-3/4”

10-1/2" x 13-1/4"

Bottom of Hood

49-2000706 Rev. 3

Installation Instructions

DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS

• This hood can be installed onto the wall or underneath the soffit or cabinet.

Centerline to Wall

• For installing the hood to soffit or cabinet, refer to page 19 for alternate mounting method.

• A wall mounting template is included with the product for ease of installation. Follow the instructions below if the template is not being used.

• Measure desired distance from the bottom of the hood to the cooking surface, 24” minimum over electric range or 30” minimum over gas range and 36” recommended maximum.

Duct Hole

Top of Hood

• Use a level to draw a horizontal line indicating the bottom of the hood.

• Measure 16-3/4” up from the horizontal line indicating the bottom of the hood. Draw another horizontal line to indicate the bottom of the installation bar.

• Use a level to draw the cooktop or range centerline location.

3-3/4”

6-5/8”

Bottom of Hood

For Ceiling Ducting:

• If venting out the ceiling, extend the centerline forward on the ceiling to the back wall.

- Measure 6-1/4” from back wall to mark center point for an 8” diameter duct hole on the ceiling.

- Cut 8" dia. duct hole on the ceiling.

For Ducting Through Rear Wall:

FOR CEILING VENT

DUCTING

Installation

Bar

10-1/2” 16-3/4”

FOR REAR WALL DUCTING

Note: Check to make sure back damper will not interfere with studs, electrical or plumbing before making cut out.

Venting Through a Soffit or Cabinet:

• Follow the same procedure for ceiling ducting to cut the hole through the top of the soffit or cabinet.

• Back damper accessory UXBDA812 must be purchased separately for venting through the rear wall.

• Measure 3-3/4” up along the centerline from the horizontal line indicating bottom of the hood.

• Make an 10-1/2" x 13-1/4” cut out centered left to right along the centerline.

House Wiring Location:

• The junction box is located inside the hood body on the left side. See Illustrations for hood knockout locations.

House wiring may enter the junction box from the rear or the top of the hood on the left side.

To route house wiring through the ceiling, soffit or cabinet:

• Cut a hole approximately 1-1/4” dia. forward on the ceiling at a distance (X) to the left of the centerline based on table below.

To route house wiring through the wall:

Note: For back venting, the house wiring must be routed through the rear knockout so it is hidden.

• Measure 15-3/4" from the bottom of the hood and mark location.

• Cut a hole approximately 1-1/4” dia. at the marked location at a distance (X) to the left of the centerline based on table below.

• Remove top or rear knockout depending on your installation.

Models "X"

30" 9-3/4"

36" 10-1/2"

1-1/4”

Top View

X

Rear View

X

15-3/4”

49-2000706 Rev. 3

17

18

Installation Instructions

1

INSTALL HOOD SUPPORT

IMPORTANT: Framing must be capable of supporting 100 lbs.

• Locate a minimum of 2 vertical studs for the installation bar by tapping drywall with a hammer or use a stud finder.

• Level the installation bar and center left to right above the marked line. Hold bar against the wall.

1

INSTALL HOOD SUPPORT (cont.)

• Install wall anchors (C) by tapping the anchors with a hammer to seat the teeth of the flanges into the wall. This keeps anchor from rotating.

• Drive the anchor screws until the barrels crimp against the inside of the wall.

• Remove the screws from the wall anchors before installing the hood.

16-3/4”

Installation Bar

Centerline of

Installation Space

2

INSTALL DAMPER

IMPORTANT: Remove shipping tape from damper and check that damper moves freely.

Install Top Damper:

• The motor mounting plate comes pre-installed in the hood for top venting.

• Install the top damper to the hood body as shown in Figure A using screws (B) from top of hood.

Figure A

Figure B

• Drill 1/8” pilot holes at the 2 vertical stud locations through holes in the installation bracket. Secure the installation bar with supplied screws (A) as shown above.

Drill Bottom Mounting Hole Locations:

• Hang hood on installation bar to mark anchor locations. Mark hole locations through the back of the hood. NOTE : If installing to the soffit or cabinet, push hood flush to the soffit or cabinet before marking screw hole locations.

• Remove the hood and drill 5/16” clearance holes centered at the marks you made.

Bottom of Hood

Centerline of

Installation Space

Wall Anchor

Locations

Install Back Damper:

• In case of back venting through the wall, back damper accessory UXBDA812 must be purchased separately.

• Remove the square knockout panel on hood body for back venting.

• Install the back damper to the hood body as shown in

Figure B using screws provided with the accessory.

• Uninstall the motor mounting plate from top venting position. Save the screws.

• Install the metal plate provided with the accessory to cover the opening for top damper.

Figure C (Single motor will look different)

Metal Brackets

• Remove the two screw knockout holes on the motor mounting plate as shown in Figure C.

• Install the motor mounting plate so that Screw Knockouts arrow is pointing upwards and on right side.

Metal Clips

• Slide plate into the metal brackets and push in until metal clips at the bottom engage.

• Fasten the plate through the two screw hole knockouts as shown in Figure C. Use the two screws you saved.

49-2000706 Rev. 3

Installation Instructions

3

INSTALL HOOD ONTO WALL

• Pull house wiring through knockout at the back or top of the hood.

• Lift the hood and place over the hooks on the installation bar. Allow the hood to slide down into position.

• Check to be sure the hood is level and centered.

• Tighten wall anchor screws (C) to finish hood body installation to the wall.

• Remove cover from junction box inside the hood.

4 (Alternate Mounting Method)

INSTALL HOOD TO SOFFIT OR

CABINET

SKIP THIS STEP IF USING WALL MOUNTING

METHOD

IMPORTANT: Soffit or cabinet framing must be capable of supporting 100 lbs.

When necessary the hood may be installed so that it is supported by the soffit or cabinet.

• The soffit should be constructed with 2"x4"s.

• Use a level to draw the cooktop or range center line.

• Continue the centerline forward on the bottom of the soffit.

• Install horizontal wood supports between the 2”x4”, at distance A to the left and right, as per the table below.

Centerline of

Installation Space

24” minimum over electric range or cooktop, or 30” minimum over gas range or cooktop, and 36” recommended maximum.

B

A

C

A

30”

Models

36”

Models

“A”

Center-line to Center

Stud

8-3/4”

13-3/4”

“B”

Opening for

Ductwork for top venting

8-3/8”x11-1/4”

“C”

Opening for

Ductwork for back venting

10-1/2”x13-1/4”

49-2000706 Rev. 3

19

20

Installation Instructions

4 (Alternate Mounting Method) INSTALL HOOD TO SOFFIT OR CABINET

(Cont.)

• Drill two 1/8” pilot holes at a distance of 10” from the back wall in the horizontal wood supports. This is the vertical distance between mounting keyholes and back wall as shown in Figure C

• The hood must also be secured to the back wall.

Follow instruction on page 18, “ Drill Bottom

Mounting Hole Locations ” section for installation to the back wall.

• Drill two more 1/8” pilot holes at a distance of 3” from the back wall in the horizontal wood supports. This is the vertical distance between mounting screw holes and back wall as shown in Figure C.

• Follow instructions on page 17, " House Wiring

Locations " section for wiring setup.

• Lift hood onto mounting screws. Slide back against the rear wall.

• For top venting, allow minimum opening (Dim. B) to accommodate damper in soffit or cabinet.

• Pull house wiring through the knockout at the rear or top of the hood.

• For back venting, allow minimum opening (Dim. C) to accommodate damper in back wall

• Tighten mounting screws (A).

• Once the hood is secured to the soffit or cabinet, drive screws (C) to secure the hood to the back wall.

Back Wall

3”

Soffit or

Cabinet

10"

1/4” Gap

A

Figure C or Cabinet

Mounting

• Drive mounting screws (A) into the studs until they protrude 1/4”. This 1/4” gap will provide clearance to engage the keyhole slots in the top of the hood.

Engage Keyhole Slots and Push Back at Wall

Back

Wall

49-2000706 Rev. 3

Installation Instructions

5 INSTALL MOTOR

I) Align the motor exhaust with the top damper as shown in the Figure A for top venting. In case of back venting, rotate the motor 90° to align with the back damper as shown in Figure B.

Figure A

Figure B

6 CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING

If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use UL approved anti-oxidant compound and aluminum-to-copper connectors.

• Remove junction box cover.

Top Venting Back Venting

II) Secure the motor to motor mounting plate using screws (D).

• Pull the house wiring through the knockout at the top or back of the hood and secure with the strain relief.

Motor Mounting Plate

III) Plug the motor connector into the mating connector on top of the control housing.

Motor mating connector location

Top Venting Installation

49-2000706 Rev. 3

• Use UL listed wire nuts to connect incoming white to white, and black to black wires.

• Loosen the green grounding screw (with grounding bracket) in the junction box. Loop solid copper house wire clockwise around the green grounding screw and above the bracket. Firmly tighten the screw over the loop.

Grounding Bracket

Green Grounding Screw

• Replace junction box cover and ensure wires are not pinched.

NOTE: For corded installation:

Use only with range hood cord-connection kits that have been investigated and found acceptable for use with this model range hood.

21

22

Installation Instructions

7 CONNECT DUCTWORK

A. Vented Installation

• Connect the house ducting to the top damper as shown in Figure A.

• For back venting, connect the transition piece to the back damper and the house ducting to the transition as shown in Figure B.

• Seal all connections with duct tape.

Ceiling

House Ducting

B. Recirculation (non-vented) Installation

NOTE: A recirculation duct (WB34X30519), and

Charcoal Filter (UXCF91), are not included with the hood and are necessary for recirculation installation.

1. Attach the recirculation duct to the duct cover mounting bracket with screws provided.

2. Connect the ducting from the exhaust outlet on the hood to the recirculation duct. Use duct tape to seal the connections.

Recirculation Duct

Figure A

Duct Cover

Mounting Bracket

Use tape

(Do not use screws.)

Wall

Figure B

Duct

Transition

House

Ducting

CAUTION

Do not use sheet metal screws at the transition to ductwork connection. Doing so will prevent proper damper operations. Seal connection with tape only.

49-2000706 Rev. 3

Installation Instructions

8 INSTALL DUCT COVERS

• Refer to section “Duct Cover Requirements” section for duct cover accessory part numbers.

• Follow instructions included with the duct cover accessory to install duct covers.

9 INSTALL GREASE TRAYS AND

FILTERS

• Remove protective film.

• Place grease drip trays into slots.

• Install the baffle filters.

• See page 7 for instructions to install or remove filters and grease trays.

2

1

49-2000706 Rev. 3

23

24

Installation Instructions

MAKE UP AIR TECHNOLOGY

This operation must be performed by a qualified technician or installer.

Note to Installers and Inspectors: This product comes equipped with a simple installation feature that limits maximum CFM levels in order to comply with certain local codes or regulations. This installation method may not be necessary for all installations, please refer to your local codes for further guidelines.

This makeup air feature applies to single motor models only.

CAUTION

Hood must be disconnected from main power prior performing the conversion instructions listed below. Failure to do so could result in personal injury or damage to the product.

To modify unit (if needed for local codes):

390CFM

By design, the maximum blower speed is greater than

400 CFM. For local codes requiring reduced CFM, modify the wiring as described below:

1. Remove the baffle filters.

2. Disconnect all the harnesses from the top of control box located on right side of motor.

3. Loosen the screws on top of control box and slide out to remove it from the hood.

4. Uninstall the control box cover.

5. For a maximum of 390 CFM Unit can operate with 4 speeds (Low, Medium, High, Boost). i. Disconnect connectors of the BROWN wire.

ii. Remove the cap attached to the connector of the

RED wire.

iii. Connect the mating connector of the BROWN wire and the RED wire.

iv. Attach the cap to the open BROWN wire connector.

6. Reinstall control box cover and secure control box to the bracket in the hood using the two screws.

7. Connect all harnesses on top of the control box.

8. Reinstall filters.

Note to Inspectors: To verify this product installation, check motor wiring connections as described above.

Motor Harness Connector

Red

Brown

Red

Motor Harness

Factory Installed

Wiring Setup

Red

Brown

Red

Motor Harness

Max 390 CFM Boost

Wiring Setup

49-2000706 Rev. 3

Troubleshooting tips ...

Before you schedule service

Save time and money! Review the charts on the following pages first and you may not need to schedule service.

Problem

Fan/Light does not operate when button is turned ON

Loud or abnormal airflow noise

Possible Cause

A house fuse may be blown or a circuit breaker tripped.

Wrong duct size used in installation.

What To Do

Replace fuse or reset circuit breaker.

Fan fails to circulate air or moves air slower than normal and/or fan is making loud or abnormal airflow noise

Obstructions in duct work.

Damper blade on wall or roof cap may not be open.

Fan keeps going off and on

Hood will not work remotely

Metal grease filter and charcoal filter (if present) may be dirty.

The motor is probably overheating and turning itself off. This can be harmful to the motor.

Router issues, no wireless signal, etc.

Hood is not connected.

This hood requires 8” ducting to perform optimally.

Using smaller duct pipe will cause reduced venting.

Minimize the duct run length and number of transitions and elbows. GE Appliances service technicians cannot correct this issue if installed improperly.

Make sure nothing is blocking the vent. Make sure your wall or roof cap has a blade or door.

Make sure damper swings freely. Damper blades may flip over and will not fully open when this happens.

Adjust to original position.

Clean the metal grease filter and replace charcoal filter

(if present). See Care and Cleaning of the Vent Hood.

Check to be sure the filters are clean. If off and on cycling continues, call for service.

For assistance with hood wireless network connectivity, please call 800.220.6899.

49-2000706 Rev. 3

25

Café Vented Range Hood Limited Warranty

cafeappliances.com

All warranty service is provided by our Factory Service Centers, or an authorized service technician. To schedule service online, visit us at cafeappliances.com/service . Please have your serial number and your model number available when scheduling service.

Servicing your appliance may require the use of the onboard data port for diagnostics. This gives a Café factory service technician the ability to quickly diagnose any issues with your appliance and helps Café improve its products by providing

Café with information on your appliance. If you do not want your appliance data to be sent to Café, please advise your technician not to submit the data to Café at the time of service.

For the period of Café will replace

One year

From the date of the original purchase

Any part of the cooking product which fails due to a defect in materials or workmanship.

During this limited one-year warranty , Café will provide, service costs to replace the defective part.

free of charge , all labor and related

What Café will not cover:

■ Service trips to your home to teach you how to use the product.

■ Improper installation, delivery, or maintenance.

■ Failure of the product if it is abused, misused, modified, or used for other than the intended purpose or used commercially.

■ Replacement of house fuses or resetting of circuit breakers.

■ Damage to the product caused by accident, fire, floods, or acts of God.

■ Damage to finish, such as surface rust, tarnish, or small blemishes not reported within 48 hours of delivery.

■ Incidental or consequential damage caused by possible defects with this appliance.

■ Damage caused after delivery.

■ Product not accessible to provide required service.

■ Service to repair or replace light bulbs, except for

LED lamps.

EXCLUSION OF IMPLIED WARRANTIES

Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty

This limited warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a Café Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized Café Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: GE Appliances, a Haier company

Louisville, KY 40225

Extended Warranties: Purchase a Café extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it online anytime at cafeappliances.com/extended-warranty

Café Service will still be there after your warranty expires.

26

49-2000706 Rev. 3

Accessories

Looking For Something More?

Café offers a variety of accessories to improve your cooking and maintenance experiences!

Refer to the Consumer Support page for website information.

The following products and more are available:

Parts

Baffle Filters

Grease Drip trays

Duct Covers

Remote Control

Charcoal Filters

Recirculation Kit

Back Venting Damper

15” Cabinet Filler Panel

Power Cord Kit

Cleaning Supplies

CitruShine™ Stainless Steel Wipes

Stainless Steel Appliance Cleaner

Bar Keepers Friend Soft Cleanser™

49-2000706 Rev. 3

27

28

Consumer Support

Café Website

Have a question or need assistance with your appliance? Try the Café website 24 hours a day, any day of the year!

You can also shop for more great Café products and take advantage of all our on-line support services designed for your convenience. In the US: cafeappliances.com

Register Your Appliance

Register your new appliance on-line at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material. In the US: cafeappliances.com/register

Schedule Service

Expert Café repair service is only one step away from your door. Get on-line and schedule your service at your convenience any day of the year. In the US: cafeappliances.com/service

Extended Warranties

Purchase a Café extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime. Café Service will still be there after your warranty expires.

In the US: cafeappliances.com/extended-warranty

Remote Connectivity

For assistance with wireless network connectivity (for models with remote enable), visit our website at cafeappliances.com/connect

Parts and Accessories

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes

(VISA, MasterCard and Discover cards are accepted). Order on-line today 24 hours every day.

In the US: cafeappliances.com/parts

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

Contact Us

If you are not satisfied with the service you receive from Café, contact us on our website with all the details including your phone number, or write to:

In the US: General Manager, Customer Relations | Café Appliances, Appliance Park | Louisville, KY 40225 cafeappliances.com/contact

Printed in Mexico

49-2000706 Rev. 3

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • QuietBoost™ Blower for powerful yet quiet operation
  • Chef Connect for wireless connection to compatible GE cooktops
  • Wi-Fi Connect for remote control
  • 3-speed fan control for optimal ventilation
  • Sleek design to complement any kitchen décor

Related manuals

Frequently Answers and Questions

How do I connect the hood to my Wi-Fi network?
Refer to the Wi-Fi Connect section of the Owner's Manual for instructions.
How do I use the Chef Connect feature?
The hood will automatically adjust its fan speed based on the settings of your compatible GE cooktop.
How do I clean the filter?
The filter can be cleaned in the dishwasher or by hand. Refer to the Filter section of the Owner's Manual for detailed instructions.

advertisement

Table of contents