Panduit Atlona OmniStream 111 is a single-channel network AV encoder designed to distribute high-quality audio and video over standard Gigabit Ethernet switches. It supports HDMI 2.0 sources up to 4K resolution, HDR, and embedded audio, making it ideal for distributing Ultra HD and HDR content. With advanced VC-2 video compression technology, it ensures visually lossless video transmission, particularly suitable for computer-generated or motion video content. The encoder also features low latency when paired with OmniStream decoders, providing a smooth and responsive AV experience.
advertisement
Installation Guide
AT-OMNI-111
OmniStream 111 Single-Channel Networked AV Encoder
AT-OMNI-111
The Atlona OmniStream™ 111 ( AT-OMNI-111 ) is a single-channel networked AV encoder for
HDMI 2.0 sources up to 4K @ 60 Hz and HDR (High Dynamic Range), plus embedded audio and RS-232 or IR control pass-through. It is part of the OmniStream Series, designed for high performance, flexible distribution of AV over standard off-the-shelf Gigabit Ethernet switches in commercial audio visual applications. The OmniStream 111 is HDCP 2.2 compliant and ideal for the latest Ultra High-Definition and HDR sources. It features advanced high-quality VC-2 visually lossless video compression technology for computer-generated imaging, or motion video content. The Atlona OmniStream™ 111 achieves extremely low, sub-frame latency when paired with OmniStream Decoders. This single-channel encoder is housed in a half-width rack with front-to-back air flow enclosure, and is ideal for high-density, compact installation in a centralized equipment location.
Package Contents
1 x AT-OMNI-111
1 x Push spring connector, 6-pin
1 x Wall/table mounting brackets
4 x Rubber feet
1 x Installation Guide
IMPORTANT : Visit http://www.atlona.com/product/AT-OMNI-111 for the latest firmware updates and User Manual.
1
Installation Guide
AT-OMNI-111
Operating Notes
• Atlona recommends using the Atlona Management System (AMS) which provides discovery, management, and configuration assistance. AMS is a free application that can be downloaded from the Atlona web site at http://atlona.com/product/at-sw-ams/.
• This product includes a built-in web interface, which can be used to manage and configure this device.
• OmniStream uses mDNS as the discovery mechanism. In order for mDNS to function properly, there must not be restrictions applied to the network. VPN can be used to connect to a computer that is running AMS, on the same network. However, VPN cannot be used when AMS is running on the local machine.
2
Installation Guide
AT-OMNI-111
Panel Descriptions
1 2 3 4 5
PWR HDMI
O
MNI
S
TREAM TM
LINK ID
HDMI IN
AT-OMNI-111
6
ETHERNET
7
RX TX
1
RS-232
8
DC 48V
9
1 PWR
This LED indicator glows bright green when the unit is powered.
2 HDMI
This LED indicator shows the input status.
3 LINK
This LED indicator is green when the link integrity between the encoder and the switch is good.
4 ID
Press this button to identify the unit within the AMS software.
5 REBOOT
Use a small, pointed object to press this recessed button and reboot the unit.
6 HDMI IN
Connect an HDMI cable from this port to an
HD source.
7 ETHERNET
Connect an Ethernet cable from this port to the Local Area Network (LAN).
8 RS-232
Use the included captive screw connector to connect an RS-232 device to this port. Refer to RS-232 on page 6 for more information.
9 DC 48V
Connect the optional 48V DC power supply to this power receptacle. This power supply is available, separately, and is required when connecting the encoder to non-PoE compatible switch.
3
Installation Guide
AT-OMNI-111
Mounting Instructions
The AT-OMNI-111 encoder includes two mounting brackets and four mounting screws, which can be used to attach the unit to any flat surface.
1. Using a small Phillips screwdriver, remove the two screws from the left side of the enclosure.
PWR
AT-OMNI-112
2. Position one of the mounting brackets, as shown below, aligning the holes on the side of the enclosure with one set of holes on the mounting bracket.
5. Repeat steps 1 through 4 to attach the second mounting bracket to the opposite side of the unit.
6. Mount the unit using the oval-shaped holes, on each mounting bracket. If using a drywall surface, a #6 drywall screw is recommended.
1
HDMI 2
1
LINK 2
DISPLA
Y
INPUT
VOLUME
ID
1
NOTE:
PWR
AT-OMNI-112
Mounting brackets can also be inverted to mount the unit under a table or other flat surface.
3. Use the enclosure screws to secure the mounting bracket to the enclosure.
Included screws
PWR
AT-OMNI-112
1
1
LINK
2
DISPLA
Y
INPUT
VOLUME
ID
1
LINK
2
DISPLA
Y
INPUT
VOLUME
ID
4. To provide added stability to the mounting bracket, use two of the included screws and attach them to the two holes, directly below the enclosure screws, as shown above.
4
HDMI IN
AT-OMNI-111
ETHERNET
Installation Guide
AT-OMNI-111
Installation
1. Connect an Ethernet cable from the ETHERNET port on the encoder to a PoE-capable switch on the Local Area Network (LAN). Note that if a PoE-capable switch is not available, the 48V DC power supply (sold separately) must be connected to the encoder.
2. C onnect an HDMI cable from a UHD/HD source to the HDMI port on the encoder.
3. If using RS-232, connect the included 6-pin captive screw connector to the RS-232 port on the encoder.
4. The PWR indicator, on the front panel, display the power status of the encoder. When the encoder is powered, using either PoE or the optional 48V DC power supply (not included), the LED initially turns red. After a few moments it will turn amber, and finally green.
PWR HDMI
O MNI S TREAM TM
LINK
HDMI IN
AT-OMNI-111
PWR indicator
ETHERNET
ID
RX TX
1
RS-232 DC 48V
Power Supply (optional)
The AT-OMNI-111 is powered by PoE (Power over Ethernet), when connected to a PoE-capable switch. If a PoE-switch is not used, then the optional 48 V power supply (Atlona part no. AT-PS-
48083-C) can be purchased, separately. Insert the positive and negative leads, from the power supply, into the terminals of the 2-pin captive screw connector block, as shown. The orange
2-pin captive screw connector block is included with the OmniStream power supply package.
DC 48V
RX
TX
1
RS-232
5
Black
Whit e
NEG
POS
PW
R
O MNI
S TREAM
TM
HD
MI
LINK
Installation Guide
AT-OMNI-111
RS-232
The AT-OMNI-111 provides transport of RS-232 protocol over IP which allows communication between a control system and an RS-232 device. This step is optional.
1. Use wire strippers to remove a portion of the cable jacket.
2. Remove at least 3/16” (5 mm) from the insulation of the RX, TX, and GND wires.
3. Insert the TX, RX, and GND wires into correct terminal on the included push spring connector, following the wiring diagram below. If using non-tinned stranded wire, press the orange tab, above the terminal, while inserting the exposed wire.
NOTE: Typical DB9 connectors use pin 2 for TX, pin 3 for RX, and pin 5 for ground. On some devices, the function of pins 2 and 3 are reversed.
Push tab to unlock
TX
RX
GND
6
Installation Guide
AT-OMNI-111
Configuration
1. Launch a web browser and enter the IP address of AMS, in the address bar.
2. Enter the required login credentials.
3. Click the Login button.
4. The AMS Dashboard will be displayed.
5. Click the icon, in the upper-left corner of the AMS Dashboard.
6. Click Devices from the fly-out menu.
7. Click the Unassigned option.
All available encoders will be displayed under the Unassigned category. When an encoder is unassigned, it means that it has not been assigned to a site, building, and/or room. Refer to the AMS User Manual for more information on these topics.
If a DHCP server is not found within 60 seconds, the encoder will be placed in Auto IP mode and assigned an IP address within the range of 169.254.xxx.xxx
. If this occurs, configure the network interface of the computer that is running AMS, located on the same subnet
( 169.254.xxx.xxx
, subnet mask 255.255.0.0
). Refer to User Manual for more information.
If no OmniStream encoders are found, then verify the following:
• The computer that is running AMS must be on the same network as the OmniStream device.
• Remove any network restrictions that may be in place. In order for mDNS to function properly, there must not be restrictions applied to the network.
7
Installation Guide
AT-OMNI-111
8. Click the desired encoder from the Unassigned device list.
Once the unit is selected, the AMS interface for the encoder will be displayed. Refer to the
User Manual for more information on the AMS interface.
Connection Diagram
OmniStream 111
Encoder
HDMI IN
AT-OMNI-111
ETHERNET
RX
TX
1
RS-232
DC 48V
Video
48V DC
Contr ol
IR OUT
SERIAL
1
SERIAL
2
1
COM NC NO
3
2
COM NC NO
COM NC NO
4
COM NC NO
+12V SI
+12V SI
+12V SI
+12V SI
HDMI
VIDEO OUT
COMPONENT
DIGIT
AL
COAX OUT
AUDIO OUT
R
AUDIO IN
OR
ETHERNET
Contr ol
Automation
Control System
LAN
2
Ethernet
Laptop
8
Installation Guide
AT-OMNI-111
Troubleshooting
Problem
PWR indicator is off.
Solution
• If using a PoE (Power-over-Ethernet) switch, make sure that the port on the switch that is connected to the encoder, has PoE enabled. When the encoder is powered using PoE, the PWR indicator will be green.
• Check the Ethernet cable for possible damage or loose connections.
• Connect the optional 48V DC power supply (available from atlona.com) to the encoder. When using an external power supply, the PWR indicator will be red.
LINK indicator is red.
• Connect an Ethernet cable to the ETHERNET port.
• Check the Ethernet cable for possible damage or loose connections.
OmniStream encoders are not displayed in AMS.
• Verify that AMS and the encoder are on the same network.
• If a DHCP server is not found within 60 seconds, the encoder will be placed in Auto IP mode and assigned an IP address within the range of 169.254.xxx.xxx. If so, then connect a laptop directly to the encoder and configure a static IP address for the encoder.
• Check the Ethernet cable for possible damage or loose connections.
• Make sure that mDNS is enabled on the network.
Also, in order for mDNS to function properly, there must not be any restrictions applied to the network.
9
Notes
Installation Guide
AT-OMNI-111
10
Notes
Installation Guide
AT-OMNI-111
11
Installation Guide
AT-OMNI-111
Toll free US International atlona.com
•
877.536.3976
•
41.43.508.4321
© 2019 Atlona Inc. All rights reserved. “Atlona” and the Atlona logo are registered trademarks of Atlona Inc. All other brand names and trademarks or registered trademarks are the property of their respective owners. Pricing, specifications and availability subject to change without notice. Actual products, product images, and online product images may vary from images shown here.
12
advertisement