Steamist SM-11 is a compact yet powerful steam generator designed to provide a relaxing and rejuvenating steam bath experience in the comfort of your home. Ideal for small to medium-sized bathrooms, this generator can fill up to 500 cubic feet of space with soothing steam. With its simple controls and easy installation, you can enjoy a spa-like ambiance and the therapeutic benefits of steam whenever you desire.
Advertisement
Advertisement
®
®
Electrical Installation Instructions
C
®
US
®
Steambath Generator Model: SM-11
The Steamist “SM” Generator operates with one or two controls appropriately located inside and/or outside the steamroom. It’s small enough in size to be tucked away using very little space in a vanity, closet, basement, or an insulated attic, but large enough to provide steam for most residential baths.
The Steamist “SM” Steambath Generator comes factory assembled, carefully wired and tested.
NOTE: The SMC-120, SMC-150, TC-125, TC-150, TC-110,
TC-135, DSC-425, and DSP Controls are designed to work with all Steamist “SM” Generators.
1.
Pre-Installation a) Proper electrical supply (208 or 240 Volt): See rating label on Steam Generator and Chart on back page. Determine proper size of wire, voltage, amperage, and phase for the
Steam Generator. 90°C copper wire is required for generator connection.
b) Dedicated overcurrent protection device, such as an in-line fuse/circuit breaker required: Fuse/circuit breaker to be installed must be sized in accordance with chart on back page. Do NOT install a GFI (Ground Fault
Interrupter) to this equipment (per article 210-8 in the
National Electric Code).
c) Route power supply cable to the location where the
Steam Generator will be installed (before walls are closed).
2.
Electrical Rough-in
a) At this time read through the installation instructions for the selected control(s).
b) Route appropriate power cable to the location the
Steam Generator will be installed. If receptacle is desired, mount the box for the receptacle near the location of the Steam Generator.
relief into knockout hole (see Figure 2: Internal
Electrical Connections).
c) Strip back power cable’s outer insulation jacket eight inches and insert into Steam Generator.
Strip back insulation ½" from the three (3) incoming wires (two power and one ground).
d) Connect incoming ground wire to floating green pigtail labeled “GND.”
CAUTION: Be sure the ground wire does not come in contact with a live electrical part. e) Connect incoming power to floating black pigtail leads labeled “L1” and “L2” (see Figure 2: Internal
Electrical Connections).
f) The Steam Generator is ready for operation once the installation of the controls is completed (refer to separate Installation and Operating Instructions).
4.
Optional Auto Drain Valve Connection a) Open knockout for Auto Drain Valve conduit connection.
b) Route flexible conduit from valve to knockout
and secure. c) Connect two wires from valve to the two place terminal strip provided (see figure 2).
Figure 1 - Steam Generator
Electrical
Panel Cover
Knockouts for
Control Cable
Water Inlet
⅜ " Compression
Fitting
!
less than 250V and proper amperage. Refer to chart on page 4 for amperage rating.
After the walls are complete, the Steam Generator and
Control can be wired.
3.
Steam Generator Electrical Installation
WARNING: All power to the Steam Generator must be turned off.
a) Remove the four screws holding the electrical access cover and remove cover.
b) Locate the supply line knockout. Mount proper strain
Install Upright and Level
Knockouts for
Electrical
Supply Line
¾" Safety
Relief Valve
¾" Steam
Outlet
Optional Auto
Drain Installed
Model SM-900
WARNING: Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or who are otherwise not in good health, do not use this device unless directed to do so by a physician. Also, do not use steambath while under the influence of alcohol. For additional Important Safety Information, please see a separate instruction Pub. No. 199.
IMPORTANT: The warranty of this product is voided if it is used in a commercial application or for anything other than a residential steambath installation. All electrical connections must be performed by a licensed electrician in accordance with Local and National
Electric Codes. This product is not intended for use with Home Automation systems.
05/11
- 1 -
Pub. No. 327-M
®
®
®
Electrical Installation Instructions
Checklist Model: SM-11
Before starting, insure that the conditions of the following checklist have been met:
The proper size Steam Generator has been selected by using the sizing page in the “Full Line Brochure,” “Pricing
Guide,” or “The Generator Sizing Guide” in the Residential Systems/Steambath Product Information section of the Steamist website - www.steamist.com.
CAUTION: An improperly sized Steam Generator will
NOT produce the amount of steam necessary to reach selected temperature.
The proper voltage Steam Generator has been selected
(i.e., 208V or 240V). A 208V Generator operating on
240V will damage the heating element, and a 240V
Generator operating on 208V will result in a 25% loss of power.
The Steam Generator is installed in an upright position.
The proper sized 90°C copper wire and circuit breaker have been used.
The circuit breaker is NOT a GFI (Ground Fault
Interrupter) type.
The Steam Generator is properly grounded.
The circuit breaker or disconnect switch is on.
Water supply is open to the Steam Generator.
Figure 2 - Major Electrical Components
Optional Steamist Splitter for Two Controls
Plug
Protective Covering
“Remove Before
Installation”
Modular Jack
Test Switch
Water
Level
Probe
Printed
Circuit
Board
Terminal Strip for Auto Drain
Connection
Optional Auto
Drain Connection
Knockout for Auto Drain
Water Inlet
⅜ " Compression
Fitting
¾" Steam
Outlet
Safety
Relief
Valve
½" Outlet
When not equipped with Auto Drain leave drain line capped and closed
05/11
- 2 -
Pub. No. 327-M
®
®
®
Figure 3 - Typical Installation
Electrical Installation Instructions
Model: SM-11
The Electrical Instructions must be given to the homeowner for future use.
NOTE: Unit must be wired with 90°C copper wire in a suitable raceway, or, if local codes allow, provide twist lock plug on a 90°C copper wire cord from generator to a 250V 2-pole, 3-wire grounding receptacle (amperage rating as required).
SMC-120 or TC-125
Auxilary Outside
Control
Inside Installation
Control should be mounted four feet from the floor. Select a location convenient to the bather but not in a direct line of
Shower or Body Sprays and not directly above the Steamhead.
START
STOP
®
Control Cable
Route from
Control to Steam
Generator in a
¾" conduit.
SMC-150 or TC-150
Control MUST be installed inside the steam room.
TEMPERATURE
START
STOP
Appropriately fuse protected
208/240V field wiring to Steam
Generator.
WARNING
HOLD THIS FITTING SECURELY WITH A PIPE
WRENCH WHILE MAKING A PLUMBING
CONNECTION TO THE WATER INLET IN ORDER
TO PREVENT INTERNAL DAMAGE TO THE WATER
SOLENOID VALVE.
009-1054
STEAMBATH GENERATOR
MODEL NO.
SERIAL NO.
VOLTS
C US
LISTED 995C kW
VOLTS
CONTROL CIRCUIT
AMPS 50/60 HZ
SERVICE BY AUTHORIZED PERSONNEL ONLY
A PRODUCT OF STEAMIST CO., RUTHERFORD, NJ
IMPORTANT: Run the Control Cable through a ¾" conduit. Remove protective cap when making the final connection to Control.
05/11
- 3 -
Pub. No. 327-M
240/208 Volt Single Phase Schematic
Electrical Installation Instructions
Model: SM-11
LED Color Chart
DS1
DS2
DS3
DS4
GRN
YEL
AMB
RED
TIMER ON
HEAT ON
WATER FILL ON
POWER ON
TEMPERATURE
®
START
STOP
Typical Steamist
Control
(Low Voltage)
Multi-Conductor
Cable*
LLC-1300-3 Circuit Board
WHT
GREY
P4
P3
P5
P13
L
H
XL
DS1 DS3
DS2 DS4
See
Chart
Fuse 0.15 AMP
Test
Switch
P18 P17
P14
GRN
GND
NOTES:
* Supplied with Controller.
**
***
Field connections, use 90ºC copper wire
Fuses only supplied with 208 Volt Single
Phase Generators.
Water
Solenoid
Valve
BLU
BLU
WHT BLK
Auto Drain
Thermostat
BLK
BLK
GRN
L1
L2
GND
**Field
Connections
Water
Level
Probe Terminal
Block
*** Fuses
GRN
GRN
Heating
Elements
Optional
Auto Drain
Valve
TANK
240/208 Three Phase Schematic
TEMPERATURE
START
STOP
®
Typical Steamist
Control
(Low Voltage)
Multi-Conductor
Cable*
LLC-1300-3 Circuit Board
WHT
GREY
P4
P3
P5
P13
L
H
XL
DS1 DS3
DS2 DS4
See
Chart
Fuse 0.15 AMP
Test
Switch
P18 P17
P14
GND
BRN
BRN
Water
Level
Probe
BLU
BLU
GRN
GRN
LED Color Chart
DS1
DS2
GRN
YEL
TIMER ON
HEAT ON
DS3
DS4
AMB
RED
WATER FILL ON
POWER ON
TANK
Heating
Elements
BLK
BLK
ORG
Terminal
Block
Auto-Drain
Sensor
Water
Solenoid
Valve
GND
L1
L2
L3
Field
Connections**
Contactor / Relay
L3 T3
L2 COIL
L1
T2
T1
Noise
Filter
Optional
Auto Drain
Valve
NOTES: * Supplied with Controller.
** Field connections, use 90ºC copper wire
Specification Chart
Model
No.
Max. Cu. Ft.
For Area Up To KW
SM-11 500 11
Volt
240
208
240
208
Phase
3
3
1
1
Amps
46
53
27
31
Line
Fuse
60
70
40
40
90°C copper wire is required for generator connection. Installation shall be in accordance with NEC and local electrical codes.
®