Advertisement
Advertisement
Automation
Power Management
Command and Signalling
Motor Applications
Product Overview for Machinery.
Build it in.
2
Planning safety and process optimization: CAD data at the click of a mouse!
• 10,800 article data items and macros
• Convenient selection tool
• Version P8
• Models for approx.
11,000 products
• 80 different neutral & native formats
Eaton is providing its customers with CAD data to offer optimum support during planning. Both electrical and mechanical design data can be called up quickly and conveniently from the Internet at any time. This reduces processing times, minimizes errors and thus reduces costs already in the engineering phase of control panels, systems and machinery.
eCAD: Eaton has product data and macros available for EPLAN Electric P8.
After downloading the small EPLANSelection program, you will not only be able to select the items you need from a database containing more than
10,800 products, but will also be able to export them and import them into your own EPLAN item database.
mCAD: Eaton makes 2D and 3D data available for more than 11,000 products.
Over 80 different neutral and native formats guarantee compatibility with the project engineering systems of the customer. The models can either be integrated directly into the planning software from the Partcommunity Portal on the Internet or via the CADENAS Partsolution software.
www.eaton.eu/cad
EATON CA08103003Z-EN-INT
Contents
Solutions for machine builders
Browse, Find, and Order – Flip Catalog and Online Catalog
Page
Touch panels XV300, XV100, XV(S)400
Remote I/O systems: XN300, XI/ON
EC4P compact PLCs, XC modular PLCs
easy control relays, MFD-Titan multi-function displays
60
easyPower, ELC-PS and PSG power supply units
ESR5 safety relays, easySafety control relays
Software: GALILEO, XSOFT-CODESYS
RMQ-Titan Pilot Devices, RMQ compact solution, FAK Foot and Palm Switches
LS position switches, iProx Series and E Series Sensors
Electronic timing relays, measuring and monitoring relays
Switching, Protecting and Driving Motors
DIL E mini contactor relays, DILER and DILA contactor relays,
DILM contactors, Z and ZEB overload relays
PKZ, PKE motor-protective circuit breakers
DS7, S801+ and S811+ soft starters
PowerXL DE1 variable speed starters, DC1, DA1, DG1 variable frequency drives
Automation with hydraulic components
NZM circuit breakers, P and PN switch-disconnectors,
BreakerVisu visualization and logging system, XMC measuring modules 230
Hydraulic magnetic circuit breakers to design a more reliable machine 244
FAZ miniature circuit breakers, FI residual current circuit breakers
A complete line of circuit protection solutions for UL markets
T rotary switches, P switch-disconnectors
CS sheet steel wall-mounting enclosures
Single-phase and three-phase UPS systems
Worldwide export of machines and plants
All-around service for your machine control systems
EATON CA08103003Z-EN-INT 3
At Eaton, we serve the needs of machine builders and their customers across the globe.
As one of the world’s leading power management companies, we provide energy efficient solutions designed to help our customers use electrical, fluid and mechanical power more reliably, efficiently, safely and sustainably. With a commitment to innovation, our solutions can help you differentiate and build a more sustainable business.
Eaton brings a new dimension of expertise.
With shorter product lifecycles, customers now expect you to design and build highly customized machines, or retrofit existing ones, faster, and at a lower cost than ever before.
Your customers demand machines that operate without fault for longer, and at the highest possible level of energy efficiency.
When designed with our best-in-class electrical and hydraulic solutions, your machines are guaranteed to deliver higher levels of accuracy, speed, energy efficiency, reliability, and flexibility. Eaton is the only solutions provider that combines hydraulic and electrical systems for a machine with power density and precision power control.
A legacy of innovation
As we have developed, our portfolio of solutions has diversified; integrating the unique capabilities of industry leading product ranges from the likes of Aeroquip, Moeller,
Vickers, Bussmann, F&G and Heinemann we now deliver innovation on a greater scale than ever before. This gives our clients the opportunity to choose the best technologies from a broad offer.
4 EATON CA08103003Z-EN-INT
For a more profitable business, build an integrated machine with Eaton solutions
A more simplified, compact and lower cost machine
Eaton significantly speeds time to market for machine builders and reduces the footprint and operating costs of machines without compromising performance. We reduce the time and expense of machine wiring, with our unique
SmartWire-DT panel-wiring solution. Our solutions, including compact hydraulic systems, also reduce machine equipment footprint and increase the speed of the manufacturing process while reducing errors.
A more reliable machine
Machines and production facilities equipped with Eaton products are more reliable, minimizing costly downtime.
Extend the service life of products by predicting hose failure before it happens with our intelligent hydraulic hose monitoring system. Uninterruptible power supplies at the machine level minimize production downtime and data loss caused by voltage dips, power outages or surges.
A safer machine
Safety needs to be a top priority as machines can create risk for your people, operation and the environment. It is vital these risks are identified and mitigated in both the design and build phases. Eaton's functional safety solutions help you meet and exceed safety regulations through product design that reduces risk of machine overload, damage and fire.
A more energy efficient machine
Increase energy efficiency with Eaton solutions that enable advanced control of electric motors and hydraulic pumps, valves and cylinders. We control and protect energy efficient
IE3 and IE4 motors. Our monitoring solutions help to reduce energy consumption.
EATON CA08103003Z-EN-INT 5
Optimise space and budget
Eaton are dedicated to offering innovative solutions that are safe, compact, reliable and financially efficient.
With budgets across the sector increasingly squeezed, the importance of reducing costs across engineering, wiring, testing and commissioning is paramount to future profitability. Eaton can help you achieve this cost reduction and improve downtime in the process.
Standardize Operations
Our portfolio of standardised solutions can revolutionise your operational efficiency. Designed to meet global standards, manage costs and reduce energy consumption,
Eaton can help you build state-of-the-art systems that are both easy to maintain and service.
Improve integrated performance
Offering compatibility with a wide variety of technology our solutions can be integrated into ready built systems to enhance flexibility, improve diagnostic output and increase communication between machines within a network.
Prioritize Safety
Safety is one of Eaton’s greatest priorities throughout the machine building process, we are dedicated to developing safer working environments and reducing operational risks.
Our solutions have been efficiently designed to meet all regulatory requirements without duplicating wiring or generating resource waste. The safeguards we implement at every stage of the process ensure risk of overload, damage or fire is minimized.
6 EATON CA08103003Z-EN-INT
Helping you to improve all parts of the machine
Intelligent Wiring
Using state-of-the-art intelligent wiring technology Eaton can help significantly reduce the costs and downtimes of your machines and systems. Our intelligent wiring solutions enhance productivity, simplify maintenance and increase flexibility when designing, installing and commissioning a plant. With a potential cost saving of up to 85% on installation costs and a guaranteed fast, error free connection, intelligent wiring presents machine builders with a great opportunity to improve profitability and performance.
Control and operation
Human machine Interfaces can help improve ergonomic performance, maximizing user comfort, efficiency and creates a better looking machine. Our XV300 touch panel delivers intuitive operation, precise gesture control and multimedia integration enabling you to manage your system effectively.
Our pilot devices help to design an attractive machine.
They are flexible and can be combined for a wide range of applications.
Energy Efficiency
The implementation of new ErP directives presents significant opportunities for machine builders. Eaton enables you to achieve compliance simply and efficiently while reducing energy costs in the process.
Circuit Protection
Eaton offers a wide range of protective solutions designed to maximise safety and protect assets. Delivering a high level of reliability our broad portfolio of solutions reduces downtime and maintenance costs, improving efficiency and reducing the risk of operational issues. Designed for the worldwide market,
Eaton’s circuit protection solutions are ideal for machine builders operating in the engineering, production, maintenance and exporting sectors globally.
EATON CA08103003Z-EN-INT 7
Energizing a world that demands more.
•
We deliver:
Electrical solutions
that use less energy, improve power reliability and make the places we live and work safer and more comfortable
•
Hydraulic and electrical solutions
that enable machines to deliver more productivity without wasting power
•
Aerospace solutions
that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently
•
Vehicle drivetrain and powertrain solutions
that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions
We provide integrated solutions that help make energy, in all its forms, more practical and accessible.
With 2014 sales of
$22.6 billion, Eaton has approximately
100,000 employees around the world and sells products in more than 175 countries.
Discover today’s Eaton.
Powering business worldwide
As a global power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses.
Eaton’s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, effi ciently, safely and sustainably.
Eaton’s electrical business
Eaton is a global leader with expertise in:
•
•
•
Power distribution and circuit protection
Backup power protection
Solutions for harsh and hazardous environments
•
•
•
•
Lighting and security
Structural solutions and wiring devices
Control and automation
Engineering services
Eaton is positioned through its global solutions to answer today’s most critical electrical power management challenges.
With 100 years of electrical experience behind us, we’re energized by the challenge of powering up a world that demands twice as much energy as today. We’re anticipating needs, engineering products and creating solutions to energize our markets today and in the future.
We are dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most.
Eaton.com
2/9/15 10:36 AM
EATON CA08103003Z-EN-INT
Energizing a world that demands more.
•
We deliver:
Electrical solutions
that use less energy, improve power reliability and make the places we live and work safer and more comfortable
•
Hydraulic and electrical solutions
that enable machines to deliver more productivity without wasting power
•
Aerospace solutions
that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently
•
Vehicle drivetrain and powertrain solutions
that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions
We provide integrated solutions that help make energy, in all its forms, more practical and accessible.
With 2014 sales of
$22.6 billion, Eaton has approximately
100,000 employees around the world and sells products in more than 175 countries.
Discover today’s Eaton.
Powering business worldwide
As a global power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses.
Eaton’s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, effi ciently, safely and sustainably.
Eaton’s electrical business
Eaton is a global leader with expertise in:
•
•
•
Power distribution and circuit protection
Backup power protection
Solutions for harsh and hazardous environments
•
•
•
•
Lighting and security
Structural solutions and wiring devices
Control and automation
Engineering services
Eaton is positioned through its global solutions to answer today’s most critical electrical power management challenges.
With 100 years of electrical experience behind us, we’re energized by the challenge of powering up a world that demands twice as much energy as today. We’re anticipating needs, engineering products and creating solutions to energize our markets today and in the future.
We are dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most.
Eaton.com
Catalog_Insert_A4_Spread_English.indd All Pages
EATON CA08103003Z-EN-INT
Our flip catalog: Get information, select, order – the fast and easy way!
http://eaton.eu/flipcat
The direct link to our flip catalog
10
This product overview is designed as a quick selection aid for our core range of machine building products. And to make it even more powerful, we have an online version with comprehensive extra features available: our digital flip catalog. The result? Getting information and placing orders is easier and faster than ever before.
How does our digital flip catalog work? Easy: Its contents are linked to the Eaton online catalog and to the relevant product pages on the Internet, meaning that clicking on a part number or article number will take you directly to all the pertinent product information. In other words, the flip catalog is the perfect way to obtain comprehensive, up-to-date information, perfectly complementing our hard copy catalog.
EATON CA08103003Z-EN-INT
Our flip catalog: Get information, select, order – the fast and easy way!
Explore our flip catalog and its powerful features
Our full range of products and our product pages only a mouse click away
Often you need more than just the items in our core range of products. This is why the pages in the flip catalog feature deep links to relevant accessories, products with expanded performance ranges, and additional product versions. And when it comes to introduction pages with general information on a product, the deep link function will take you to the relevant detailed product pages on the Internet.
Technical data at a glance
Clicking on a product will show the corresponding data sheet with all technical data and dimensional drawings. In addition, you can use the available options to access CAD data, trip characteristics, manuals, instruction leaflets, and other information.
Easily generate parts lists and place orders
You can use the flip catalog to select products and group them together in a parts list. This parts list can then be used together with the online catalog to request quotations, place orders, or maintain required documentation.
The InfoPlus icon: your access to more information
Clicking on the InfoPlus icon will show additional information such as configurators, selection aids, software, tutorial videos, technical essays, and Internet pages. This information ensures that you will get a comprehensive view that perfectly complements our product overview for machinery.
M22-PV
216876
M22-PV
216876
M22-PV
216876
Up-to-date information on the entire range of products in the online catalog
More than 25,000 data sheets, extensive selection aids, and up-to-date product information in a variety of languages – all in our online catalog http://eaton.eu/ecat
EATON CA08103003Z-EN-INT 11
M22-PV
216876
SmartWire-DT®
SmartWire-DT in the control panel
“Connect, don't wire” standard devices
HMI/PLC, Open HMI
• Display sizes of 7" and 10,1"
• Gesture-based controls made possible by capacitive multi-touch technology
Remote I/O
XN300, slice-card-based modular I/O system
• Compact, up to 20 channels per slice card
• Display sizes of 3.5", 5.7", 7"; flush-mounting devices
• Display sizes of 5.7", 7"; rear-mounting devices
• Display sizes: 5.7", 8.4", 10"
PLC
EC4P compact PLC
• Centralized and decentralized expandable
Compact PLC XC152
• Onboard SmartWire-DT (depending on model)
• Control and visualization software in one single device
ea
yRelay, MFD-Titan
• For applications with up to 12 I/Os
• “Circuit diagram programming” ea s y700 control relay
• For applications with up to 40 I/Os
• “Circuit diagram programming”
MFD-80 MFD-Titan display/operating unit
• Remote monochrome text display for all easyRelays
MFD-CP8/CP10 MFD-Titan power supply/
• easy800 functionality plus visualization
MFD-CP4 MFD-Titan power supply/CPU module
Safety Technology
Detect hazards quickly with the RMQ-Titan emergency-stop actuator
• A variety of emergency stop switch designs
• Self-monitoring contact elements
12 EATON CA08103003Z-EN-INT
Keeping movement safely under control with the LS-Titan position switch
SmartWire-DT in distributed devices
“Connect, don't wire” sensors and actuators
Page 14
HMI and HMI/PLC
XV400 / XVS400
• Display sizes: 5.7", 8.4", 10.4", 12.1", 15"
• Versatile and powerful communications
Multi-touch industrial panel PC
XP-503
• 10.1"; 15.6"; 21.5", wide-screen
• Same intuitive ease of use as a smartphone
Page 34
Page 84 ff.
XI/ON standard, modular I/O system
• Fine granularity
• Communicative
XI/ON PLC
• Featuring a CANopen gateway that can be programmed with CODESYS
Galileo
CODESYS
XC101 modular PLC
• Expandable with XI/OC modules
• Fiber optic CAN interface
(depending on model)
Programming and visualization software
• HMI
• HMI/PLC
• PLC
• easy control relay
• MFD-Titan
Page 48
Page 88
Page 60
XC201/202 modular PLC
• High computing power
• High processing speed
• CODESYS Target Viso ea s y800 control relay
• Expandable, networkable via easyNet
• For applications with up to 328 I/Os
• “Circuit diagram programming”
MFD-Titan I/O modules
• For digital and analog I/Os
• Pt100
• Ni1000
ESR5 Safety Relays
• A separate safety relay for each safety application
Page 68
Control relay ea s y800 with SmartWire-DT
• Can be networked with easyNet
(depending on the model)
• Can accommodate up to a max. of
1,328 I/Os
• “Circuit diagram programming”
24 V DC power supplies
• Single-phase or three-phase devices with currents of 0.35 A to 40 A
Page 80
Safety manual Page 82
Control relays suitable for safety circuits
– easySafety
• “All-in-one” versatile safety functions and easy functionality combined in a single device
SmartWire-DT®
SmartWire-DT in the control panel
“Connect, don't wire” standard devices
HMI/PLC, Open HMI
HMI and HMI/PLC
XV 300
• Display sizes of 7" and 10,1"
• Gesture-based controls made possible by capacitive multi-touch technology
Remote I/O
XN300, slice-card-based modular I/O system
• Compact, up to 20 channels per slice card
(12.5 x 102 mm)
• Easy and efficient to use
HMI and HMI/PLC
XV102
• Display sizes of 3.5", 5.7", 7"; flush-mounting devices
XV112
• Display sizes of 5.7", 7"; rear-mounting devices
XV152
• Display sizes: 5.7", 8.4", 10"
XI/ON ECO, modular I/O system
• Space-saving
• High channel density
PLC
EC4P compact PLC
• Centralized and decentralized expandable
Compact PLC XC152
• Onboard SmartWire-DT (depending on model)
• Control and visualization software in one single device
ea
s
yRelay, MFD-Titan
ea s y500 control relay
• For applications with up to 12 I/Os
• “Circuit diagram programming” ea s y700 control relay
• For applications with up to 40 I/Os
• Expandable
• “Circuit diagram programming”
MFD-80 MFD-Titan display/operating unit
• Remote monochrome text display for all easyRelays
MFD-CP8/CP10 MFD-Titan power supply/
CPU module
• easy800 functionality plus visualization
MFD-CP4 MFD-Titan power supply/CPU module
• For remote text display
Safety Technology
Detect hazards quickly with the RMQ-Titan emergency-stop actuator
• A variety of emergency stop switch designs
• Self-monitoring contact elements
Page 96 ff.
Page 122 ff.
Keeping movement safely under control with the LS-Titan position switch
• Safety door switches
• Safety position switch
SmartWire-DT in distributed devices
“Connect, don't wire” sensors and actuators
• Display sizes: 5.7", 8.4", 10.4", 12.1", 15"
• Versatile and powerful communications
Multi-touch industrial panel PC
• 10.1"; 15.6"; 21.5", wide-screen
• Same intuitive ease of use as a smartphone
XI/ON standard, modular I/O system
• Featuring a CANopen gateway that can be programmed with CODESYS
XC101 modular PLC
• Expandable with XI/OC modules
• Fiber optic CAN interface
(depending on model)
Programming and visualization software
Page 60
XC201/202 modular PLC
• High computing power
• High processing speed
• CODESYS Target Viso
• Expandable, networkable via easyNet
• For applications with up to 328 I/Os
• “Circuit diagram programming”
Control relay ea s y800 with SmartWire-DT
• Can be networked with easyNet
• Can accommodate up to a max. of
• “Circuit diagram programming”
• Single-phase or three-phase devices with currents of 0.35 A to 40 A
• A separate safety relay for each safety application
Control relays suitable for safety circuits
• “All-in-one” versatile safety functions and easy functionality combined in a single device
EATON CA08103003Z-EN-INT 13
®
SmartWire-DT®: The communication and wiring system for more profitability
Catalog download: www.eaton.eu/catalog
Customer expectations today are focused on increased performance in a more compact design, shorter delivery times, and the right price. To meet these requirements, machines need to be built in shorter time frames, using smaller control cabinets with intelligent, energy-saving devices that allow a smaller footprint compared with existing components.
For plants and systems the availability is the key to higher profitability.
SmartWire-DT is a unique wiring solution that streamlines connection and communications inside and outside control panels.
Machine and system builders globally are finding that SmartWire-DT can be integrated easily into machines in a smaller control cabinet, reducing the time and effort for wiring their machines and systems by up to 85 %.
In Operation the profitability of the machines and system can be raised.
Digital and analog data help to improve the performance and to avoid downtimes.
14 www.eaton.eu/swdproducts
EATON CA08103003Z-EN-INT
Simplify wiring. Reduce costs. Improve flexibility
Today, control wires are used to connect devices like switchgear or pilot devices to PLC I/O-modules. Using SmartWire-DT, these modules and the control wiring becomes obsolete. All devices are connected to this intelligent wiring system, reducing engineering and installation costs for the machine builder.
Less complex, more compact machines
Eliminating the PLC I/O and the control wiring means more compact control panels and machines, and makes automation structures simple to design and configure.
Simplified connectivity
By replacing conventional, time-consuming control circuit
wiring with one single cable, SmartWire-DT enables the simple connection of switchgear in control panels, as well as sensors and actuators outside control panels. This results in safe and error-free switchgear installations combined with significantly shorter commissioning times.
Higher flexibility
With industrial fieldbus gateways, SmartWire-DT can be connected to PLCs from any manufacturer, giving the machine builder the flexibility to easier meet customer demand.
More compact machines with Eaton controllers
For small and medium machines, Eaton offers HMI/PLCs, compact PLC and control relays with integrated SmartWire- DT communication interface. This offers machine builders the opportunity to develop simpler, more compact automation solutions.
Extended communication improves system effectiveness
Plants need multiple drives, control and pilot devices to be designed, installed and controlled, along with distributed sensors and actuators. Automation of the process environment can be quite challenging, especially if continuous process availability is required. SmartWire-DT is an intelligent wiring system that provides more data on installed devices, central to increased availability and preventive maintenance.
More data, increased availability
More detailed information enables better process control, more detailed diagnostics, reduced downtime and increased availability. SmartWire-DT switchgear devices provide continuous real-time data information on motor load conditions that allows an interaction before an overload situation occurs and the system stops. Monitoring motor current values also helps with preventive maintenance. The overall result is improved system availability and higher economic effectiveness.
Easy expansion
SmartWire-DT makes it easy to add expansions during operation. New devices are simply connected to the communication cable inside or outside the control panel. An overall length of up to 600m simplifies distributed control architectures.
EATON CA08103003Z-EN-INT 15
16
®
Automate with CODESYS
The compact PLC series XC152 combines a modern control architecture and comprehensive communication interfaces in a single device.
Meanwhile, HMI PLCs combine the latest IT technologies with traditional PLC and HMI technologies by grouping control, visualization, and data management tasks together in a single device. In both cases, the integrated SmartWire-DT interface makes it much easier to communicate with switchgear.
SmartWire-DT – twice as easy with easySoft
Our new easy800 devices with SmartWire-DT combine the functions of an easy800 control relay with a direct connection to SmartWire-DT. Instead of having to connect switchgear inputs and outputs to the corresponding controller individually, they can simply be connected via a SmartWire-DT line instead.
Programming remains the same, using ladder diagrams in easySoft-Pro.
Open for every master with different gateways
Eaton offers gateways for a wide variety of standard field bus systems so that you can establish communications with any controller. The following protocols are supported: PROFIBUS-
DP, CANopen, EtherNet/IP, Modbus/TCP, PROFINET, Ethercat and Powerlink.
EATON CA08103003Z-EN-INT
Convenient control and signaling
Due to the fact that every single contact and indicator light has to be wired individually to a controller's input/output modules, conventional pilot device wiring is associated with a high level of complexity and cost. The perfect alternative is SmartWire-
DT, which instead connects pilot devices with just a single click.
Functions that previously needed to be set up separately, such as those in double pushbuttons with LED indicators, now require a single SmartWire-DT function element only. Moreover, SL signal towers can also be connected to SmartWire-DT.
SmartWire-DT: All the information you need regarding your motors
With SmartWire-DT, PKE motor-protective circuit breakers rated for currents of up to 65 A can be easily integrated into automation systems. The function element for these circuit breakers not only reports their trip setting, but also their trip state and the cause of any trips. Moreover, it also sends data concerning the motor current and the thermal motor load, providing advance warning of potential faults and shutdowns due to overload. The result is increased availability and serviceability.
Efficient power distribution monitoring
The modular design behind PKE motor-protective circuit breakers ensures that they can also be used as circuit breakers for load currents of 15 A to 65 A in power distribution applications. In addition, combining them with the PKE-SWD-CP
SmartWire-DT module makes it possible to evaluate phase current, trip state, breaker setting, and advance overload warning monitoring signals, eliminating the need for conventional measuring equipment.
Starting
Protecting
Connect machine sensors directly
IP67 I/O modules provide SmartWire-DT systems with a finegrained I/O solution that features a high degree of protection and can be used directly on machines. The small number of
I/O channels means that even individual sensors and actuators can be connected to a SmartWire-DT system directly in the field by using these modules. This not only reduces the amount of wiring needed, but also renders a machine's wiring simpler. All in all, digital and analog sensors and actuators can be easily connected in any order and amount, and expansions can be conveniently added by simply adding new cards.
Reversing
Stopping
Compact motor start
Combining an EMS electronic motor starter with
SmartWire-DT results in a compact package with a width of
30 mm that can be used to drive and monitor motor feeders carrying up to 3 kW (400 V). Moreover, integrated functions for motor DOL starting, reversing starting, motor protection, and emergency stop functionality up to SIL 3 not only eliminate the need to use several standard components, but also the need to wire them. Finally, driving and monitoring the electronic motor starter's drive via SmartWire-DT makes wiring faster and enables users to detect critical machine states in advance.
PowerXL variable frequency drives/variable speed starters – communicate efficiently
PowerXL variable frequency drives and variable speed starters can be combined with SmartWire-DT as well.
To do so, it is only necessary to plug a SmartWire-DT function element into the device, completely eliminating the need for conventional control circuit wiring. The new interface makes it possible to configure the variable frequency drives centrally, and the network connection can be used to send control commands to the devices and read diagnostic data from them.
DS7 soft starters – direct access to all parameters
DS7 soft starters are available within a performance range of
1.1 to 110 kW, and by connecting them to SmartWire-DT, you can obtain easy and convenient access to all their parameters.
Users can read and overwrite potentiometer settings.
Extended status, error, and diagnostic messages can be retrieved directly. The result: absolute data transparency.
The plug-in units make installation fast and error-free, and the resulting connection includes the soft starter's control current supply.
Visualization and logging system – BreakerVisu
Measuring electrical parameters is the foundation of any energy management system. With SmartWire-DT, the operational data of NZM circuit breakers and PKE motor-protective circuit breakers can be visualized and logged using Breaker-
Visu. This self-configuring system allows for up to 16 cards to be connected to it via SmartWire-DT and, alternatively, another 32 via Modbus RTU. Once connected, it can be used to read important information, such as phase currents, trip states, and configuration parameters, via SmartWire-DT. In addition, energy values can be obtained via energy measuring modules.
EATON CA08103003Z-EN-INT 17
18
One system, countless possibilities.
Visualization
HMI
XV100/XV300 any
PLC
Control relay easy806
SmartWire-DT enables distributed intelligence that changes automation. Interface modules installed on standard switchgear replace the digital and analog I/O layer on PLCs. Gateways to any industrial fieldbus make it not just possible, but simple to access the SmartWire-DT network independent of the PLC system. At the same time,
SmartWire-DT technology is available as an integrated part of our controllers. The result: easy-to-configure, linear automation structures with few components.
Powerful technology
Up to 99 devices can be connected on a single SmartWire-DT line. The maximum permissible total length is 600m, while the maximum data volume for cyclic process data is 1,000 bytes. The
SmartWire-DT cable also includes the required power supply for the SmartWire-DT electronics as well as for installed contactors.
Flexible integration in every automation environment
Fieldbus gateways are used to connect the SmartWire-DT communication system to your individual PLC system.
SmartWire-DT can communicate via industrial fieldbus using standardised mechanisms for configuring and parameter setting.
SmartWire-DT modules
Two different types of SmartWire-DT modules are available.
Special function modules replace the electrical interfaces of contactors, pushbuttons, pilot devices and auxiliary switches.
Intelligent devices like electronic motor protective devices, softstarters and drives transmit digital and analog information (e.g. current, overload..) directly onto the SmartWire-DT network.
KEY
Control
Compact PLC
XC152
HMI/PLC
XV100/XV300
SmartWire-DT ®
Any fieldbus
Inside and outside the cabinet
SmartWire-DT can also be used to directly connect sensors and actuators in the field. This is done with T-Connectors, available as digital and analog I/O modules with an IP67 degree of protection.
EATON CA08103003Z-EN-INT
KEY
SmartWire-DT ®
Any fieldbus
SmartWire-DT gateway
Operate
Signal tower SL
Start a motor
Variable frequency drive
DC1, DA1
Input/Output
Inside the cabinet
Digital
Analog
Temperature
Outside the cabinet
Variable speed starter DE1 / DE11
Control circuit devices RMQ-Titan
Circuit breaker
NZM
Circuit
Protection
Control circuit devices in surface mounting enclosure
Module for NZM
Soft starter
DS7
Electronic motor starter EMS
Motor-protective circuit breaker PKE 65
Miniature circuit breaker FAZ
Residual current circuit breaker FRC
Motor starter combination with PKE/PKZ
10 V
; 20 mA
°C
°C
Actuator
Valve
Valve
Electrical and Hydraulic
Special dedicated SmartWire-DT modules can be used to directly control 2/3-position or proportional hydraulic valves.
EATON CA08103003Z-EN-INT 19
CA08103003Z_MOEM2015-EN.book Seite 20 Donnerstag, 7. April 2016 12:02 12
SmartWire-DT®
System overview
System overview
3
6
6
4
6
5
7
10
10
10
12
Moeller® series
2
56
7
49
6
48
6
37
6
8
9
11
1
17 19
20
55
16
14
6
10
10
13
10
15
10
15
10
18
10
7
21
22
23
6
6
27
7
10
28
6
47
10
35
29
36
30
22
24
10
23
30
32
24
26
26
31
32
39
40
40
38
33
34
25
26
10
DE1
41
23
26
35
44
6
53
54
45
6
42
10
50
10
51
10
50
10
49
52
10
42
10
6
43
46
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 21 Donnerstag, 7. April 2016 12:02 12
Moeller® series
1 Compact PLC
2 Touch panel
3 PLC with field bus interface
4 Gateways
5 Control relays
6 SWD blade terminal, 8 pole
7 SWD ribbon cable, 8 pole
8 SWD I/O module
9 SWD module for circuit-breakers and residual current circuitbreakers
10 SWD external device plug, 8 pole
11 SWD interface for NZM
12 NZM circuit-breakers
13 SWD contactor module
14 DILM contactor
15 SWD contactor module with manual 0 automatic switch
SmartWire-DT®
Communication system
45 DA1 variable frequency drives 17 MSC motor starters
18 SWD PKE module (motor starter)
32 SWD LED elements for base fixing
19 Motor starters with PKE electronic motor protection
33 SWD function elements for base fixing
20 DS7 soft starters with PKE electronic motor protection
34 SWD universal modules, base fixing
21 SWD universal module, front mount
35 SWD plug-in connector, 8 pole
22 SWD LED element, front mount
31 SWD card for function elements, base fixing
36 SWD round cable, 8 pole
23 RMQ-Titan mounting clamps for flush mounting plates 37 SWD adapter for flat/round cable for top-hat rail mounting
24 RMQ-Titan indicator lights
38 SWD PKE module (motorprotective circuit-breaker)
25 SWD function elements for front mount
26 SWD operating elements
39 PKE motor-protective circuitbreakers
27 SWD power feeder module
40 Soft Starter DS7
41 DE1 Variable speed starter
28 SWD control panel bushing ribbon cable to 8 pole round cable, M20 42 SWD function element for
DC1 variable frequency drive,
DE1 variable speed starter
29 SWD control panel bushing ribbon cable to 5 pole round cable, M12
30 Surface mounting enclosure
RMQ-Titan
43 SWD function element for
DA1 variable frequency drive
44 DC1 variable frequency drives
46 SWD bus termination resistor for
8 pole flat band conductor
47 M12 plug connector, 5 pole
48 Round cable, 5-pole
49 SWD I/O module IP67, 2 I/O
50 SWD I/O module IP67, 4 I/O
51 SWD I/O module IP67, max. 16 I/O
52 SWD bus termination resistor
IP67 for 5 pole round cable, M12
53 Base module signal tower
SL4/SL7
54 Signal towers SL4 /SL7
55 Electronic Motor Starter EMS
56 SmartWire-DT planning and ordering aid (SWD-Assist)
Features
SmartWire-DT coordinators
Touch panel
With SWD master switch and PLC function
3.5“ , 5.7“, 7“ or 10“ TFT-LCD screen, additional field bus interfaces, Ethernet, WEB server
C ompact controller
With SWD master switch
Additional fieldbus interfaces, Ethernet, WEB server
Control relay
With SWD master switch
Gateways
Connection of SmartWire-DT to fieldbus (e.g. CANopen,
Profibus, Profinet …)
Supply voltage for the SmartWire-DT modules
Feeder unit for the control voltage for the motor starter or contactor
Support of up to 99 SmartWire-DT modules
SmartWire-DT module
I/O modules to connect digital and analog input/output signals in IP20, IP67 degree of protection
DS7 Soft starter with integrated connection
Function element to connect to:
• Pilot devices RMQ-Titan
• SL4/7 signal tower
• Contactor DILM
• Motor-protective circuit-breaker PKZ/PKE
• PKE32,65 circuit-breaker
• NZM2,3,4 circuit-breakers
• Miniature circuit breaker (MCB)
• DE1 Variable speed starter
• DC1, DA1 variable frequency drives
SmartWire-DT-Assist (SWD-Assist)
Easily create SmartWire-DT networks integrated validity check
Generate order lists.
Online functions:
• Configuration check and comparison
• Display of all input/output data, setting outputs
• Display of parameters and diagnostics
Free download at www.eaton.eu/swd
Communication system
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 22 Donnerstag, 7. April 2016 12:02 12
SmartWire-DT®
Coordinators
Coordinators
Screen diagonal
Inch
Resolution
Pixel
Built-in interfaces Part no.
Moeller® series
Article no.
Touch display with integrated controller
XV100
Windows CE 5.0 (licence incl.), Approvals: cUL (UL508)
Slots for SD card: 1
Resistive touch with TFT display, 64 k colors
Standard front with standard membrane (fully enclosed)
Insulating enclosure and front plate
3.5
5.7
QVGA
320 x 240
VGA
640 x 480
7 WVGA
800 x 480
XV150
Metal enclosure and front plate
5.7
VGA
640 x 480
8.4
10.4
✓
✓
✓
✓
✓
-
✓
✓
✓
✓
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
✓
-
✓
-
-
✓
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
✓
-
✓
-
✓
-
✓
-
✓
-
✓
✓
✓
✓
✓
✓
✓
XV-102-BE-35TQRC-10
XV-102-E6-57TVRC-10
XV-102-E8-57TVRC-10
XV-102-E6-70TWRC-10
XV-102-E8-70TWRC-10
153524
153525
153526
153527
153528
XV-152-E6-57TVRC-10
XV-152-E8-57TVRC-10
XV-152-E6-84TVRC-10
XV-152-E8-84TVRC-10
XV-152-E6-10TVRC-10
XV-152-E8-10TVRC-10
166700
166701
166702
166703
166704
166705
Built-in interfaces Part no.
Article no.
XV300
Windows Embedded Compact 7 Pro, Approvals: cUL 61010-2-201
Slots for SD card: 1
Resolution: WSVGA 1024 x 600 Pixel
PLC licence inclusive
Capacitive multi-touch technology (PCT), Number of colours: 16 mil.
Model: Plastic enclosure and glass panel in plastic frame
XV300 7"
-
-
✓
✓ -
-
✓
✓
XV300 10.1"
-
✓
-
✓
-
✓
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
✓
✓
✓
✓
✓
✓
✓
✓
XV-303-70-BE0-A00-1C
XV-303-70-CE0-A00-1C
XV-303-70-BE2-A00-1C
XV-303-70-CE2-A00-1C
179655
179656
179657
179658
XV-303-10-BE0-A00-1C
XV-303-10-CE0-A00-1C
XV-303-10-BE2-A00-1C
XV-303-10-CE2-A00-1C
179667
179668
179669
179670
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 23 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Built-in interfaces
SmartWire-DT®
Part no.
Coordinators
Article no.
XC compact PLCs
24 V DC power supply
Lot for memory card
RUN/STOP switch and LED displays
OPC Server
Integrated Web server
Approvals: CE, cULus
Application/marker/retain data 64 MB/4 KB/32 KB KByte
Cycle time for 1 k of instructions (Bit, Byte) 0.04 ms
✓
✓
✓ -
-
✓ -
✓
✓
✓
✓
✓
-
-
✓
-
-
✓
✓
✓
✓
XC-152-E3-11
XC-152-E6-11
XC-152-E8-11
167850
167851
167852
Inputs
Digital Of which can be used as outputs
SmartWire-DT
Outputs
Transistor SmartWire-DT
Real time clock Part no.
easy800 control relay
Combines the functionality of an easy800 with direct connection to SmartWire-DT communication system
Up to 99 SmartWire-DT modules with a total of up to 166 digital inputs/outputs and/or up to 128 analog inputs/outputs can be connected via a SmartWire-DT line
Supply voltage 24 V DC
83 83 ✓
Article no.
EASY802-DC-SWD 152901
4 2 83 2 83 ✓ EASY806-DC-SWD 152902
Baud Rates Number of
SmartWire-DT slaves
Gateways
Used to connect the SmartWire-DT communication system to industrial field bus systems. Powers SmartWire-DT modules and switchgear
For connection to PROFIBUS-DP field bus
Field bus connection via 9 pole SUB-D socket
Separate RS232 diagnostics interface (RJ45)
For connection to CANopen® field bus
Field bus connection via 9 pole SUB-D plug
Separate RS232 diagnostics interface (RJ45) up to
12 MBit/s
Max. 58 up to 1 MBit/s Max. 99
For connection to the Ethernet-IP/MODBUS-TCP field bus
Field bus connection via Ethernet Switch
Separate RS232 diagnostics interface (RJ45)
10/100 MBit/s Max. 99
Part no.
EU5C-SWD-CAN
EU5C-SWD-DP
Article no.
116307
116308
EU5C-SWD-EIP-MODTCP 153163
For connection to field bus PROFINET as PROFINET IO-Device
Field bus connection via Ethernet Switch
Separate USB diagnostics interface (Mini-USB)
For connection to a POWERLINK field bus as a slave
Field bus connection via Ethernet hub
Separate USB diagnostics interface (Mini-USB)
For connection to an EtherCAT fieldbus as a slave
Field bus connection via Ethernet Switch
Separate USB diagnostics interface (Mini-USB)
100 MBit/s
100 MBit/s
100 MBit/s
Max. 99
Max. 99
Max. 99
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
EU5C-SWD-PROFINET 170124
EU5C-SWD-POWERLINK 171797
EU5C-SWD-ETHERCAT 177354
CA08103003Z_MOEM2015-EN.book Seite 24 Donnerstag, 7. April 2016 12:02 12
SmartWire-DT®
Module, Input/output modules (IP20)
Module, Input/output modules (IP20)
Input/output modules (IP20)
Digital modules IP20
For connection of digital I/O signals
For use with: ribbon cable, SWD coordinators
The outputs are short-circuit proof.
The outputs are short-circuit proof.
Inputs with supply for sensor system.
Analog modules IP20
For connection of analog I/O signals
For use with ribbon cable, SWD coordinators
Inputs configurable: 0 - 10 V, 0 - 20 mA
Inputs/outputs, configurable: 0 - 10 V, 0 - 20 mA -
-
Configurable inputs: PT100, PT1000, Ni1000
Temperature range °C :
PT100, PT1000: -50 - +200
Ni1000: -50 - +150
Configurable inputs: PT100, PT1000, Ni1000
Temperature range °C :
PT100, PT1000: -100 - +400
Ni1000: -50 - +200
-
-
4
4
8
4
Inputs Outputs
Digital Analog Relay
-
-
-
-
-
4
2
4
4
-
-
2
-
-
-
-
-
-
-
-
-
Transistor Analog
-
-
8
-
4
-
-
-
-
-
-
-
-
2
Part no.
EU5E-SWD-8DX
EU5E-SWD-4D4D
EU5E-SWD-4D2R
EU5E-SWD-X8D
EU5E-SWD-4DX
EU5E-SWD-4AX
EU5E-SWD-2A2A
EU5E-SWD-4PT
EU5E-SWD-4PT-2
Moeller® series
Article no.
116381
116382
116383
144061
144060
144062
144063
144064
172560
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 25 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Module, Input/output modules (IP67)
Short Description
Input/output modules (IP67)
Digital modules IP67
For connection of digital I/O signals
-
Freely configurable inputs/outputs, max. 2
The outputs are short-circuit proof.
Inputs
Digital
2
≤ 2 -
-
Analog
Outputs
Transistor Analog
Part no.
-
≤ 2
Module, Input/output modules (IP67)
-
-
SmartWire-DT®
EU1E-SWD-2DX
EU1E-SWD-2DD
Article no.
174711
174715
-
Freely configurable inputs/outputs, max. 4
The outputs are short-circuit proof.
4
≤ 4
Analog modules IP67
For connection of analog I/O signals
Input: 0 - 10 V
Input: 0 - 20 mA
Output: 0 - 10 V
Output: 0 - 20 mA
Configurable inputs: PT100, PT1000,
Ni1000Temperature range °C :
PT100, PT1000: -100 - +400
Ni1000: -50 - +200
-
-
-
-
-
Counter module IP67
For connecting a meter
Meter/incremental encoder 24 V DC, max. 30 kHz
-
-
-
-
-
1
1
2
-
-
-
-
-
-
-
≤ 4 -
EU2E-SWD-4DX
EU2E-SWD-4DD
174726
174732
-
-
-
-
1
1
EU1E-SWD-1AX-1
EU1E-SWD-1AX-2
EU1E-SWD-1XA-1
EU1E-SWD-1XA-2
EU2E-SWD-2PT
EU1E-SWD-1CX
174717
174718
174719
174720
174733
174721
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 26 Donnerstag, 7. April 2016 12:02 12
SmartWire-DT®
Module, Control and Indication
Module, Control and Indication
Contacts Colour
SmartWire-DT RMQ connections
For combination with RMQ-Titan operating elements M22-...
Function elements
1 changeover contact
2 changeover contact without LED without LED
Front fixing
Part no.
M22-SWD-K11
M22-SWD-K22
Article no.
Base fixing
Part no.
Moeller® series
Article no.
115964
115965
M22-SWD-KC11
M22-SWD-KC22
115995
115996
LED elements
-
-
-
-
1 changeover contact
2 changeover contact
M22-SWD-K11LED-W
M22-SWD-K11LED-B
M22-SWD-K11LED-G
M22-SWD-K11LED-R
M22-SWD-K22LED-W
M22-SWD-K22LED-B
M22-SWD-K22LED-G
M22-SWD-K22LED-R
115972
115973
115974
115975
115978
115979
115980
115981
M22-SWD-LED-W
M22-SWD-LED-B
M22-SWD-LED-G
M22-SWD-LED-R
115966
115967
115968
115969
Description
Signal towers Basic modules
For horizontal mounting, including cover, max. 5 modules,
Base with base adapter for slipping onto place (rapid mounting and wiring system)
Blade terminal SWD4-8MF2 max. 0.3 A per module
External power supply connectable (24 V DC)
Configurable with SWD ‐ Assist (planning and ordering help)
Further technical data, see manual MN05006001Z.
Tube length For use with
100 mm
100 mm
SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
Part no.
SL4-SWD
SL7-SWD
M22-SWD-K11LEDC-W 116003
M22-SWD-K11LEDC-B 116004
M22-SWD-K11LEDC-G
M22-SWD-K11LEDC-R
116005
116006
M22-SWD-K22LEDC-W 116009
M22-SWD-K22LEDC-B
M22-SWD-K22LEDC-G
M22-SWD-K22LEDC-R
116010
116011
116012
M22-SWD-LEDC-W
M22-SWD-LEDC-B
M22-SWD-LEDC-G
M22-SWD-LEDC-R
115997
115998
115999
116000
Article no.
171311
171459
Encoder
Description
Potentiometer
Front element SmartWire-DT potentiometer
Only in conjunction with M22-SWD-R function element
Function element SmartWire-DT potentiometer
Only in conjunction with M22-R-SWD front element
Front element SmartWire-DT encoder
With actuation function
Only in conjunction with M22-SWD-INC function element
Function element SmartWire-DT encoder
Only in conjunction with M22-INC-SWD front element
EATON CA08103003Z-EN-INT
Configuration Part no.
M22-R-SWD
Article no.
179292
179293 14 36 25
M22-SWD-R
M22-SWD-INC
M22-SWD-R
M22-INC-SWD 179981
14 36 25 M22-SWD-INC 179982
M22-SWD-R
M22-SWD-INC
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 27 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Module, Switching, protecting and driving motors
Description
Contactor modules 1),2)
For connecting the contactors to SmartWire-DT
Per contactor 1 module necessary.
Messages
Switch status Contactor, status of the digital inputs 1 and 2
Commands
Contactor actuation
SmartWire-DT®
Module, Switching, protecting and driving motors
For use with Part no.
Article no.
1-0-A switch for manual or automatic operation.
Messages
Switch status Contactor, status of the digital inputs 1 and 2, 1-0-A switch position
Commands
Contactor actuation
DILM(C)7… -
DILM(C)32
DILM38
DILA
MSC-D(E)-...(24VDC)
DIL-SWD-32-001
118560
DILM(C)7… -
DILM(C)32
DILM38
DILA
MSC-D(E)-...(24VDC)
DIL-SWD-32-002
118561
PKE module (motor-starter combinations) 1)
For connecting PKE motor-starter combination MSC-DEA… with PKE-XTUA-... trip blocks with a rated motor output of 15 kW/400 V to SmartWire-DT
SmartWire-DT module for connection of motor-starter combination, model “Extended” 24 V DC (MSC-DEA-…) up to 15 kW.
1 module per contactor and PKE.
Mounting on DILM contactor with 24 V DC control voltage.
One module per contactor and PKE necessary
Additional SWD contactor module required fir actuation of reversing starter.
1 electrical interlock for the surface mounting of reversing starters.
1-0-A switch for manual or automatic operation.
Selectable overload relay function (ZMR) for switching off the contactor on overload.
Connecting cable between module and trip block PKE-XTUA-… included as standard.
Messages
Switch position contactor/PKE/1-0-A switch
Motor current in %
Thermal motor image in %
Trip indications (Overload, Short-circuit,...)
Set value of overload releases
Set time lag (CLASS)
Part no. of trip block
Commands
Contactor actuation
Activation Overload relay function (ZMR)
DILM(C)7… -
DILM(C)32
MSC-DEA
PKE module (motor-protective circuit-breaker)
For connecting the motor-protective circuit-breaker with PKE-XTU(W)A-... trip blocks(motor protection) to SmartWire-DT
Fitted on PKE motor-protective circuit-breaker
Messages
Contactor state PKE
Motor current in %
Thermal motor image in %
Trip indications (Overload, Short-circuit,...)
Set value of overload releases
Set time lag (CLASS)
Part no. of trip block
Commands
Remote disconnection of motor-protective circuit-breaker
PKE module (circuit-breaker)
For connecting the PKE circuit-breaker with PKE-XTU(W)ACP-... trip blocks(motor protection) to SmartWire-DT for 2 function elements M22-SWD-K22…
For attachment to PKE circuit-breakers
Messages
Contactor state PKE
All phase currents in %
Thermal load as a %
Trip indications (Overload, Short-circuit,...)
Set value of overload releases
Set short-circuit release value
Part no. of trip block
Commands
Remote circuit-breaker de-energization
PKE12
PKE32
PKE65
PKE32
PKE65
Notes 1)
2)
For current consumption of the contactor coils > 3 A (UL: 2 A) use additional power feed module.
A2 connections must not be bridged.
Wiring sets DILM 12-XRL and PKZM0-XRM12 cannot be used.
Connection terminals for electrical interlocking are not suitable for safety technology.
PKE-SWD-32
126895
PKE-SWD-SP
150614
PKE-SWD-CP
172735
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 28 Donnerstag, 7. April 2016 12:02 12
SmartWire-DT®
Module, Switching, protecting and driving motors
Description
Moeller® series
Article no.
Setting range of overload releases Part no.
I r
A_x
Electronic motor starter
For connecting to SmartWire-DT for expanded diagnostics.
DOL starters
(complete devices)
Reversing starters
(completedevices)
Controlled stop via additional enable signal terminal up to SIL3/Ple.
DOL starters
(complete devices)
Reversing starters
(complete devices)
0,18 - 2,4
1,5 - 7 (AC-53a)
9 (AC-51)
0,18 - 2,4
1,5 - 7 (AC-53a)
9 (AC-51)
0,18 - 2,4
1,5 - 7 (AC-53a)
9 (AC-51)
0,18 - 2,4
1,5 - 7 (AC-53a)
9 (AC-51)
EMS-DO-T-2,4-SWD
EMS-DO-T-9-SWD
EMS-RO-T-2,4-SWD
EMS-RO-T-9-SWD
170106
170107
170108
170109
EMS-DOS-T-2,4-SWD
EMS-DOS-T-9-SWD
EMS-ROS-T-2,4-SWD
EMS-ROS-T-9-SWD
170110
170111
170112
169790
I e
A
Rated operational current device
(AC-53)
Soft starters
Soft starters for three-phase loads, Mains supply voltage (50/60 Hz) U
LN
200 - 480 V AC
Control voltage U
C
= 24 V DC, Supply voltage U s
= 24 V DC
4
Assigned motor rating at 400 V, 50 Hz at 460 V, 60 Hz
P P kW HP
1.5
2
7
9
3
4
5
5
24
32
12
16
11
15
5.5
7.5
15
25
10
10
135
160
200
70
81
41
55
100
75
90
110
37
45
22
30
55
100
125
150
50
60
30
40
75
Part no.
Article no.
DS7-34DSX004N0-D
134943
DS7-34DSX007N0-D
134945
DS7-34DSX009N0-D
134946
DS7-34DSX012N0-D
134947
DS7-34DSX016N0-D
134948
DS7-34DSX024N0-D
134949
DS7-34DSX032N0-D
134950
DS7-34DSX041N0-D
134952
DS7-34DSX055N0-D
134953
DS7-34DSX070N0-D
134954
DS7-34DSX081N0-D
134955
DS7-34DSX100N0-D
134956
DS7-34DSX135N0-D
134957
DS7-34DSX160N0-D
134958
DS7-34DSX200N0-D
134959
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 29 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Module, SWD function elements
Connection technique
Power XL™ variable frequency drives
Fieldbus connection (optional)
For connecting DA1 variable frequency drives (IP20/IP55) to SmartWire-DT
Plug-in module with slot for SWD4-8SF2-5 external device plug
For use with
SmartWire-DT®
Module, SWD function elements
Part no.
Article no.
DA1 (IP20, IP55) DX-NET-SWD1
169129
For connecting DE1 variable speed starter and DC1 variable frequency drives (IP20) to SmartWire-DT
Plug-in module (front) with slot for SWD4-8SF2-5 external device plug
DE1, DE11, DC1 (IP20) DX-NET-SWD3
169131
Description Part no.
Article no.
NZM compact circuit breakers
SmartWire-DT interface for NZM
The module implements the data connection between the NZM2/3/4 with electronic release and the SmartWire-DT.
A switch with a remote operator can also be remotely operated with the module.
Two digital inputs for the switch status
2 transistor outputs for remote switching
Retentive memory for energy data (kWh)
Energy data is transmitted through digital input (S0) from an external energy measuring module NZN...-XMC-SO.
A connection cable (1.90 m) for the circuit-breaker and two NZM auxiliary contacts (1 x NO, 1 x NC) are included as standard.
NZM-XSWD-704
135530
Part no.
Article no.
Short Description Side mounting
Safety switching devices XEffect
The module establishes the connection to miniature circuit-breakers, residual current circuit-breakers, and residual current operated circuit-breakers with overcurrent protection
Fuse auxiliary contact
Accessories for combined residual-current/power circuit-breakers
Accessories for residual current circuit breakers
Accessories for miniature circuit breaker for fitting on left to: FI for fitting on right to: LS, FI/LS
MCB-HK-SWD
177175
Power feeder module
Description
For feeding control voltage in order to connect additional motor starters and contactors to the
SmartWire-DT ribbon cable
For the formation of emergency switching off groups for motor starters and contactors
Part no.
Article no.
EU5C-SWD-PF1-1
116309
For feeding supply voltage in order to connect additional SmartWire-DT modules to the SmartWire-DT ribbon cable
For additional control voltage feeder for the motor starter and contactors
For the formation of emergency switching off groups for motor starters and contactors
For feeding supply voltage in order to connect additional SmartWire-DT modules (IP 67) and connected sensors/actuators
EU5C-SWD-PF2-1
116380
EU1S-SWD-PF1-2
174724
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 30 Donnerstag, 7. April 2016 12:02 12
SmartWire-DT®
Accessories
Accessories
Description Protection type
(IEC/EN 60529,
EN50178, VBG 4)
Length m
SWD Connection cables
SWD ribbon cable
For connecting the SmartWire-DT modules within the control panel
8 pole
Not ready-assembled
8 pole
Prefabricated with two blade terminals SWD4-8MF2
SWD round cable
For connecting pilot devices in Cl surface mounting enclosures
8 pole
HK-S0-Li2YY, 8 mm diameter
IP67
IP67
SWD round cable
For connecting peripheral SmartWire-DT cards
5 pole
Prefabricated with M12 socket and M12 plug, A-keyed
I/O round cable
For directly connecting sensors/actuators to IP67 SWD modules
5 pole prefabricated on one side with M12 plug, A-keyed
I/O round cable
For directly connecting sensors/actuators to IP67 SWD modules
5 pole
Prefabricated with M12 socket and M12 plug, A-keyed
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP20
IP20
IP20
IP20
1
2
0.3
0.6
1
2
0.3
0.6
3
5
100
10
50
250
3
4
1.5
2
5
10
0.6
1
0.1
0.3
20
Part no.
Article no.
Moeller® series
SWD4-100LF8-24
116026
SWD4-10LF8-24-2S
116029
SWD4-3LF8-24-2S
116027
SWD4-5LF8-24-2S
116028
SWD4-50LR8-24
116030
SWD4-250LR8-24
144878
SWD4-M1LR5-2S
174760
SWD4-M3LR5-2S
174761
SWD4-M6LR5-2S
174762
SWD4-1LR5-2S
174763
SWD4-1M5LR5-2S
174764
SWD4-2LR5-2S
174765
SWD4-3LR5-2S
174766
SWD4-4LR5-2S
174767
SWD4-5LR5-2S
174768
SWD4-10LR5-2S
174769
SWD4-20LR5-2S
174770
SWD4-M3LR5-S
174771
SWD4-M6LR5-S
174772
SWD4-1LR5-S
174697
SWD4-2LR5-S
174698
SWD4-M3LR5-1-2S
179543
SWD4-M6LR5-1-2S
179544
SWD4-1LR5-1-2S
179545
SWD4-2LR5-1-2S
179546
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 31 Donnerstag, 7. April 2016 12:02 12
Moeller® series
SmartWire-DT®
Accessories
Description Function Protection type
(IEC/EN 60529,
EN50178, VBG 4)
Length m
SWD enclosure and control panel cable gland
8 pole M20 socket
8 prefabricated cables for connection to PCB M22-SWD-I...
For flush mounting in
M22-I... surface mounting enclosure
IP67 0.15
8 pole M20 plug
8 prefabricated cables for connection to PCB M22-SWD-I...
IP67 0.15
Part no.
Article no.
SWD4-SF8-20
116031
SWD4-SM8-20
116032
Connection round cable via socket
Connection of ribbon cable with blade terminal SWD4-8MF2
8 pole
Double conductor run pluggable
Additional control voltage feeder for the motor starter and contactors.
Connection round cable via plug
Connection of ribbon cable with blade terminal SWD4-8MF2
8 pole
Double conductor run pluggable
Additional control voltage feeder for the motor starter and contactors.
SmartWire-DT control panel bushing for 8-conductor ribbon cable to 5-conductor round cable, separate 24 VDC 4 A power supply for round cable
From IP67 to IP20, from 5-conductor round cable to
8-conductor ribbon cable, integrated 15 VDC 180 mA power supply unit for SmartWire-DT modules on the ribbon cable
Control panel cable gland for 5-conductor SWD4-…LR8-24
M12 SmartWire-DT round cable, M12 plug/socket
For transition from
SWD ribbon cable to
SWD round cable
SWD4-…LR8-24
For transition from
SWD round cable to
SWD ribbon cable
SWD4-…LR5-2S
For transition from
SWD round cable
SWD4-…LR5-2S to
SWD ribbon cable
For flush mounting in an enclosure
IP67
IP67
IP67
IP67
IP67
5 pole M12 socket, A-coded
5 prefabricated cables
5 pole M12 plug, A-coded
5 prefabricated cables
5 pole M12 socket, A-coded
5 prefabricated cables
5 pole M12 plug, A-coded
5 prefabricated cables
For flush mounting in an enclosure
For flush mounting in an enclosure
For flush mounting in an enclosure
For flush mounting in an enclosure
IP67
IP67
IP67
IP67
-
-
-
-
-
1
1
0.15
0.15
SWD4-SFL8-20
121380
SWD4-SML8-20
121381
Description Function Protection type
(IEC/EN 60529,
EN50178, VBG 4)
Part no.
Article no.
SWD plugs and plug-in connections
8-pin SmartWire-DT external device plug that can be connected at any point on the ribbon cable.
External device plugs can be used to connect the function elements of any SmartWire-DT module in a control panel.
For connecting the ribbon cable to
SmartWire-DT modules in the control panel
IP20 SWD4-8SF2-5
116022
SWD4-SFL8-12
174756
SWD4-SML8-12
174755
SWD4-SML5-12
174757
SWD4-PRF5-1-S
174758
SWD4-PRM5-1-S
174759
SWD4-PRF5-2-S
179541
SWD4-PRM5-2-S
179542
SWD4-8MF2
116023
8-pin SmartWire-DT blade terminal that can be installed at both ends of the SmartWire-DT ribbon cable.
The following components can be connected: SmartWire-DT coordinators such as easy800-SWD / SmartWire-DT gateway, SmartWire-DT power feeder module,
SmartWire-DT coupling, SmartWire-DT bus termination resistor, SmartWire-DT control panel bushings
Cap with monitoring function for M12 bushings on SWD connector (IP67)
For connecting the ribbon cable to the gateway, power feeder module, coupling, SWD4-RC8-10 bus termination resistor
Cover cap with monitoring function for M12 socket
IP20
IP67
Cap for M12 sockets on SWD connector (IP67)
Cap for M12 plugs on SWD connector (IP67)
Cap for M12 socket
Cover cap for M12 plug
IP67
IP67
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
SWD4-ACAP-10
174751
SWD4-PCAP-F
174752
SWD4-PCAP-M
174753
CA08103003Z_MOEM2015-EN.book Seite 32 Donnerstag, 7. April 2016 12:02 12
SmartWire-DT®
Accessories Moeller® series
Description Function
SWD plugs and plug-in connections
8 pole socket
Straight
Soldering connection
8-pinplug connector
Straight
Soldering connection
Splitter with IP67 degree of protection, M12 plug into two
M12 sockets with I/O signal on pin 4
Splitter with IP67 degree of protection, M12 plug into two
M12 sockets with I/O signal on pin 2
Splitter with IP67 degree of protection, M12 plug into two
4 pole M8 sockets with I/O signal on pin 2
Splitter with IP67 degree of protection, M12 plug into two
4 pole M8 sockets with I/O signal on pin 4
Splitter with IP67 degree of protection, M12 plug into two
3 pole M8 sockets
5 pole socket
Straight
Screw connection
Plug connector for 8-pole
SWD4-…LR8-24 round cables
For splitting an M12 I/O connection's I/O signals
Plug connector for 5 pole
SWD4-…LR5-.. round cables
IP67
IP67
IP67
IP67
IP67
IP67
Protection type
(IEC/EN 60529,
EN50178, VBG 4)
Part no.
Article no.
IP67
IP67
SWD4-SF8-67
116033
SWD4-SM8-67
116034
SWD4-SP-4124
174703
SWD4-SP-4122
174704
SWD4-SP-4084
174705
SWD4-SP-4082
174706
SWD4-SP-3084
174707
SWD4-SF5-67
179547
5 pole plug
Straight
Screw connection
Plug connector for 5 pole
SWD4-…LR5-.. round cables
IP67 SWD4-SM5-67
179548
SWD coupling
Coupling via two 8-pin blade terminals To connect SWD ribbon cables over SWD4-8MF2 blade terminals
IP20 SWD4-8SFF2-5
116024
SWD cable adapters
For connection flat cable (plug) on round cable (terminal) SWD cable adapters IP20
SWD power supply module for modules (IP20) on a local
SWD segment
SmartWire-DT cable adapter for putting together a local
SmartWire-DT segment
SWD power supply module
SWD cable adapters
IP20
IP20
SWD4-8FRF-10
121377
SWD4-FFR-PF1-1
168880
SWD4-FFR-ST1-1
168881
To set up a local SWD network with SWD modules (IP67)
SWD bus termination resistor
SmartWire-DT bus termination resistor; plugged onto
SWD4-8MF2 blade terminal at the end of the SmartWire-DT ribbon cable
Local SmartWire-DT branch
For the SmartWire-DT bus termination resistor on the
SmartWire-DT ribbon cable
SmartWire-DT bus termination resistor with IP67 degree of protection, connected to 5-conductor SWD4-..LR5.. round cable or directly to SmartWire-DT T-Connectors
(IP67 I/O modules)
For IP67, M12 SWD bus termination resistor
IP67
IP20
IP67
EU2A-SWD-PBWN
174734
SWD4-RC8-10
116020
SWD4-RC5-10
174754
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z-en-EN_030-033__SWD_A4_g.fm Seite 33 Donnerstag, 7. April 2016 1:11 13
Moeller® series
Link
SmartWire-DT®
Accessories
Function
For bridging open mounting locations for SWD4-8SF2-5 external device plugs
-
Protection type
(IEC/EN 60529,
EN50178, VBG 4)
Part no.
Article no.
SWD4-SEL8-10
116021
RMQ
For 2 function elements M22-SWD-K22…
For two M22-SWD-NOP universal modules
For mounting 1 base function element
For mounting 2 base function elements
For mounting 3 base function elements
For mounting 4 base function elements
For mounting 6 base function elements
For bridging of open mounting locations on card
-
-
-
-
-
-
M22-SWD-A4
116016
M22-SWD-I1-LP01
115990
M22-SWD-I2-LP01
115991
M22-SWD-I3-LP01
115992
M22-SWD-I4-LP01
115993
M22-SWD-I6-LP01
115994
M22-SWD-SEL8-10
116698
Universal module
For configured but not yet installed SWD modules connected to the SWD ribbon cable
IP20
For configured but not yet installed SWD modules on the
M22-SWD-I... card
IP20
Tools for plugs
For configured but not yet installed SWD modules connected to the SWD ribbon cable SWD4-..LR5-2S
IP67
Crimping tool for joining external device plugs and ribbon cable -
Crimping tool for making contacts with blade terminals and ribbon cables -
Programming accessories
For transferring the user program to the PLC or for diagnosing
SmartWire-DT networks
For transferring the user program to the PLC or for diagnosing
SmartWire-DT networks
Programming and visualisation software
-
-
-
M22-SWD-NOP
147637
M22-SWD-NOPC
147638
EU1M-SWD-NOP
174716
SWD4-CRP-1
116025
SWD4-CRP-2
116699
EU4A-RJ45-CAB1
106726
EU4A-RJ45-USB-CAB1
115735
EASY-SOFT-PRO
266040
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
34
XV HMI/PLC: Systematic visualization and control
All devices can also be used in portrait format
With the XV HMI-PLC touch panels Eaton is offering customers in the machine and system building sector a systematically coordinated range that can be integrated perfectly into different performance classes.
The smart implementation of the PLC runtime into a slim and efficient embedded platform strategy in combination with powerful processors creates a state-of-the-art, scalable and cost-efficient automation concept. The use of the CODESYS programming standard, together with a comprehensive range of ports and interfaces and the ability to use over 100 protocols as an HMI, demonstrates the system's open nature.
Display sizes from 3.5" to 15"; plastic, metal, and stainless steel models; and the option of using capacitive, resistive, or infrared touch panels allow for an extremely wide range of applications.
Unique on the market: XV panels with an onboard SmartWire-DT master interface. This offers potential savings affecting all aspects of a project, from hardware planning to software creation, to wiring and commissioning.
www.eaton.eu/xv
EATON CA08103003Z-EN-INT
XV300: The new face of today's industry
Intuitive user guidance, precise gesture-based controls, multimedia integration – the ease of use we experience every day on our smartphones and tablets has now become a reality in industrial applications as well: Our new XV300 panels with capacitive multi-touch technology are not just tremendously intuitive – they are redefining how man and machine interact.
Streamlined, high-resolution devices ready to meet your needs
– even in harsh industrial conditions. The devices are cULus type approved.
XV300
• Two display sizes: 7 " and 10.1
" widescreen
• Available in front-mounting and rear-mounting versions
• Sleek, space-saving design
• Flat, anti-glare toughened glass panel
• The ability to switch between landscape and portrait mode as needed
• Perfect fit in control consoles, resulting in a flat surface without any sharp edges
• High system performance and a powerful graphics processing unit
3
4 5 6
7 8 9
SD-Card Slot
2 USB-Host
3 Two or one
Ethernet ports
4 RS232
5 RS486
6 SmartWire-DT available
7 Profibus DP/MPI/
PPI available
8 CAN
9 24 VDC
Numerous interfaces and expandable memory
An impressive variety of ports and interfaces provides maximum versatility for extensive networking. Whether you need CANopen ® , EtherNet/IP, EtherCAT, Modbus (TCP/
RTU), PROFIBUS-DP ® , or SmartWire-DT ® – the wide variety of fieldbus interfaces ensures that you will be able to use the right protocol for your application. Moreover, the two Ethernet ports, which are independent from each other, make it possible to safely and reliably separate the open control layer from the function-specific field layer. An SD card slot makes it possible to expand the device's internal memory if necessary. In addition, the SD card can be used to conveniently load system updates or to boot and run the entire system from it if necessary.
One-stop hardware and software
With Galileo Version 10, Eaton has brought its visualization software to a whole new level designed to make planning and configuring systems easier than ever. Featuring design styles and gestures such as swipe, scroll, and pinch-to-zoom,
Galileo is the ideal companion to the advantages provided by the XV300 series. Moreover, HMI/PLC models can be programmed with either XSoft-CODESYS Version 2 or 3.
SmartWire-DT on board
SmartWire-DT supports Eaton's concept by helping create flexible automation solutions with fewer components and less engineering work. How? Simple: SmartWire-DT integrates communications and the I/O layer directly into the corresponding operating units, display devices, and switchgear. This enables PLCs to use SmartWire-DT to directly access digital and analog data from sensors all the way to circuit breakers and lets systems efficiently process control commands, eliminating the need for a separate gateway and I/O layer.
EATON CA08103003Z-EN-INT 35
XV100: Compact and powerful operating units
XV100 touchscreen panels are based on a common hardware platform. More specifically, all of them run on Windows CE
5.0, are powered by the same high-performance 400 MHz processor, and feature a modular interface concept, which makes it possible to offer devices with a wide variety of interface and interface combinations. Moreover, all the devices in the XV100 family have been cULus type approved.
• Can be used in portrait or landscape mode
• Removable SD card
• Integrated web server
• Programmable with CODESYS V2 and V3
• CODESYS Targetvisu
• Visualization with GALILEO
XV-102
Resistive touchscreen panel in a plastic enclosure with a plastic bezel ; 3.5", 5.7", 7" wide
• Devices at the perfect price point and with the ideal functions for applications requiring pure HMIs, HMI PLCs, or HMIs that can be retrofitted with a PLC function
• Shallow mounting depth
• Interface and interface combinations: CAN, PROFIBUS/MPI,
SmartWire-DT, RS485, RS232
SD memory card
2 USB device
3 USB Host
4 Ethernet
SD memory card
2 USB device
3 USB Host
4 Ethernet
5 POW and AUX
24-V power supplies
6 SmartWire-DT interface
7 On-board interfaces, depending on type
5 POW and AUX
24-V power supplies
6 SmartWire-DT interface
7 On-board interfaces, depending on type
XV-152
Resistive touchscreen panel in a metal housing with an aluminum bezel; 5.7", 8.4", 10.4"
• With their shallow mounting depth, heavy-duty metal housing, fully laminated aluminum structure bezel, and plenty of basic features, XV-152 devices are as compelling as it gets.
• Versions for use as HMI PLCs or as HMIs that can be retrofitted with a PLC function
• Interface and interface combinations: CAN, PROFIBUS/MPI,
SmartWire-DT, RS485, RS232
• Mounting dimensions fully compatible with XV(S)400 devices
XV-112
Resistive touchscreen panel in a metal enclosure for use as a rear-mounted unit; 5.7" and 7" wide
XV-112 devices are designed to be mounted from behind on an enclosure door or with a front frame of your choice. A film on the front, which is flexible and transparent in the display's viewing area, seals off the structure in the front. These rearmounting devices can be used as operating and monitoring devices or as integrated operating and control devices. A 7" version meets with the approval requirements of the following classification societies:
Lloyd’s Register (LR), Germanischer Lloyd (GL), Det Norske
Veritas (DNV), and Bureau Veritas (BV).
36 EATON CA08103003Z-EN-INT
15
16
1
5
2
180°
5
8
180°
3
8
5
1
9
10
2
11
3
HMI/PLC
System overview
6
6
4
180°
8
4
12
13
14
1 XV-102/XV-112 touch display with PLC, resistive touch technology 3.5", 5.7" and 7.0" widescreen
2 XV-152 touch display with PLC, resistive touch technology
5.7", 8.4" and 10.4"
3 XV-3x3 touch display with PLC, capacitive multi-touch technology, 7.0" or 10.1" widescreen
4 XV(S)-400 touch display with PLC, infrared or resistive touch technology, 5.7", 8.4", 10.4", 12.1", or 15"
5 SD memory card
6 Compact flash memory card
7 Communication module for XV-400
8 SmartWire-DT
7
9 License product certificate PLC for XV-1x2
10 License product certificate for communication expansion for XV-1x2
11 License product certificate PLC for XV-3x3
12 License product certificate PLC for XV(S)-400
13 License product certificate for communication expansion for XV(S)-400
14 License product certificate for Windows CE5
15 License product certificate GALILEO
16 License product certificate XSOFT-CODESYS-2/3
EATON CA08103003Z-EN-INT 37
CA08103003Z-en-EN_038-040__Touchdisplay_A4_g.fm Seite 38 Mittwoch, 13. April 2016 9:23 09
XV100
HMI/HMI-PLC touch display with PLC
HMI/HMI-PLC touch display with PLC
Screen diagonal
Inch
PLC-licence Built-in interfaces Part no.
Article no.
XV100 without PLC
Resistive-Touch
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
1 x Ethernet 10/100 Mbps
1 x USB device
Number of colours: 32 grey levels
3.5
Number of colours: 64 k Colours
3.5
5.7
7
No PLC function possible -
-
✓
-
✓
-
-
-
-
✓
No PLC function possible ✓
-
-
✓
-
✓
-
✓
-
✓
-
✓
-
-
-
-
-
-
-
-
-
-
✓
✓
✓
-
-
✓
✓
-
-
-
-
-
-
-
-
-
-
-
-
-
✓
-
-
XV-102-A0-35MQR-10
XV-102-A2-35MQR-10
XV-102-A3-35MQR-10
XV-102-A4-35MQR-10
XV-102-A5-35MQR-10
XV-102-H3-35TQRL-10
XV-102-H4-35TQRL-10
XV-102-H3-57TVRL-10
XV-102-H4-57TVRL-10
XV-102-H3-70TWRL-10
XV-102-H4-70TWRL-10
141759
141820
141821
141822
141823
171158
171159
171160
171161
171162
171163
PLC-licence Built-in interfaces Part no.
Article no.
XV100 3.5"
Resistive-Touch, QVGA 320 x 240 Pixel
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
1 x Ethernet 10/100 Mbps
1 x USB device
Number of colours: 32 grey levels
Including
Number of colours: 64 k Colours
Can be fitted by user with article no. 142581
LIC-PLC-MXP-COMPACT
Including
-
-
-
✓
-
-
✓
-
-
-
✓
✓
-
-
✓
-
✓
-
-
✓
✓
-
-
-
-
-
-
-
✓
-
✓
✓
-
-
-
-
✓
✓
-
-
✓
-
-
-
-
✓
-
✓
-
-
✓
-
-
-
-
-
-
✓
-
-
-
-
-
-
-
-
-
-
-
-
-
✓
-
-
-
-
-
-
-
✓
-
-
-
-
✓
EATON CA08103003Z-EN-INT
XV-102-B0-35MQR-10-PLC
XV-102-B3-35MQR-10-PLC
XV-102-B5-35MQR-10-PLC
XV-102-B6-35MQR-10-PLC
XV-102-B8-35MQR-10-PLC
XV-102-B0-35TQR-10
XV-102-B2-35TQR-10
XV-102-B3-35TQR-10
XV-102-B4-35TQR-10
XV-102-B5-35TQR-10
XV-102-B0-35TQR-10-PLC
XV-102-B3-35TQR-10-PLC
XV-102-B4-35TQR-10-PLC
XV-102-B5-35TQR-10-PLC
XV-102-B6-35TQR-10-PLC
XV-102-B8-35TQR-10-PLC
XV-102-BE-35TQRC-10
140012
140013
140015
140016
140017
140007
140008
140009
140010
140011
140018
140019
140020
140021
140022
140023
153524
Complete assortment -> www.eaton.eu/ecat
CA08103003Z-en-EN_038-040__Touchdisplay_A4_g.fm Seite 38 Mittwoch, 13. April 2016 9:23 09
XV100
HMI/HMI-PLC touch display with PLC
HMI/HMI-PLC touch display with PLC
Screen diagonal
Inch
PLC-licence Built-in interfaces Part no.
Article no.
XV100 without PLC
Resistive-Touch
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
1 x Ethernet 10/100 Mbps
1 x USB device
Number of colours: 32 grey levels
3.5
Number of colours: 64 k Colours
3.5
5.7
7
No PLC function possible -
-
✓
-
✓
No PLC function possible ✓
-
-
✓
-
✓
-
✓
-
✓
-
✓
-
-
-
-
✓
-
-
-
-
-
-
-
-
-
-
✓
✓
✓
-
-
✓
✓
-
-
-
-
-
-
-
-
-
-
-
-
-
✓
-
-
XV-102-A0-35MQR-10
XV-102-A2-35MQR-10
XV-102-A3-35MQR-10
XV-102-A4-35MQR-10
XV-102-A5-35MQR-10
XV-102-H3-35TQRL-10
XV-102-H4-35TQRL-10
XV-102-H3-57TVRL-10
XV-102-H4-57TVRL-10
XV-102-H3-70TWRL-10
XV-102-H4-70TWRL-10
141759
141820
141821
141822
141823
171158
171159
171160
171161
171162
171163
PLC-licence Built-in interfaces Part no.
Article no.
XV100 3.5"
Resistive-Touch, QVGA 320 x 240 Pixel
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
1 x Ethernet 10/100 Mbps
1 x USB device
Number of colours: 32 grey levels
Including
Number of colours: 64 k Colours
Can be fitted by user with article no. 142581
LIC-PLC-MXP-COMPACT
Including
-
-
-
✓
-
-
✓
-
-
-
✓
✓
-
-
✓
-
✓
-
-
✓
✓
-
-
-
-
-
-
-
✓
-
✓
✓
-
-
-
-
✓
✓
-
-
✓
-
-
-
-
✓
-
✓
-
-
✓
-
-
-
-
-
-
✓
-
-
-
-
-
-
-
-
-
-
-
-
-
✓
-
-
-
-
-
-
-
✓
-
-
-
-
✓
XV-102-B0-35MQR-10-PLC
XV-102-B3-35MQR-10-PLC
XV-102-B5-35MQR-10-PLC
XV-102-B6-35MQR-10-PLC
XV-102-B8-35MQR-10-PLC
XV-102-B0-35TQR-10
XV-102-B2-35TQR-10
XV-102-B3-35TQR-10
XV-102-B4-35TQR-10
XV-102-B5-35TQR-10
XV-102-B0-35TQR-10-PLC
XV-102-B3-35TQR-10-PLC
XV-102-B4-35TQR-10-PLC
XV-102-B5-35TQR-10-PLC
XV-102-B6-35TQR-10-PLC
XV-102-B8-35TQR-10-PLC
XV-102-BE-35TQRC-10
140012
140013
140015
140016
140017
140007
140008
140009
140010
140011
140018
140019
140020
140021
140022
140023
153524
38 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 39 Donnerstag, 7. April 2016 12:02 12
HMI-PLC touch display with PLC
PLC-licence Built-in interfaces Part no.
XV100
HMI-PLC touch display with PLC
Article no.
XV100 5.7"
Resistive-Touch, VGA 640 x 480 Pixel
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
Number of colours: 64 k Colours
1 x Ethernet 10/100 Mbps
1 x USB device
Can be fitted by user with article no. 142581 LIC-PLC-MXP-
COMPACT
Including
-
-
✓
✓
✓
✓
✓
✓
Without front plate
Rear mounting
Including ✓
-
-
✓
✓
-
✓
-
-
✓
✓
✓
✓
✓
✓
-
✓
✓
✓
-
-
-
-
-
-
-
-
-
✓
✓
✓
✓
✓
✓
✓
✓
✓ -
-
-
✓
-
-
-
-
✓
-
-
-
✓
-
✓
-
-
✓
XV-102-D0-57TVR-10
XV-102-D4-57TVR-10
XV-102-D6-57TVR-10
XV-102-D8-57TVR-10
XV-102-D6-57TVRC-10
XV-102-D8-57TVRC-10
XV-102-E6-57TVRC-10
XV-102-E8-57TVRC-10
XV-112-D6-57TVRC-00
142530
150620
142531
142532
142533
142534
153525
153526
153469
XV100 7"
Resistive-Touch, WVGA 800 x 480 Pixel
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
Number of colours: 64 k Colours
1 x Ethernet 10/100 Mbps
1 x USB device
Can be fitted by user with article no. 142581 LIC-PLC-MXP-
COMPACT
Including
-
✓
-
✓
✓
✓
✓
✓
Without front plate
Rear mounting
Including ✓ -
-
✓
-
✓
-
✓
-
-
-
✓
✓
✓
✓
✓
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
-
-
-
-
-
-
✓ -
-
-
✓
-
-
-
-
✓
-
-
-
✓
-
✓
-
-
✓
XV-102-D0-70TWR-10
XV-102-D4-70TWR-10
XV-102-D6-70TWR-10
XV-102-D8-70TWR-10
XV-102-D6-70TWRC-10
XV-102-D8-70TWRC-10
XV-102-E6-70TWRC-10
XV-102-E8-70TWRC-10
XV-112-DB-70TWRC-00
142535
150621
142536
142537
142538
142539
153527
153528
153470
Without front plate
Rear mounting
Shipping classification GL, LR,
DNV, BV
Including ✓ ✓ ✓ XV-112-DB-70TWRC-70 172909
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 40 Donnerstag, 7. April 2016 12:02 12
XV150
HMI-PLC touch display with PLC
HMI-PLC touch display with PLC
PLC-licence Built-in interfaces Part no.
Article no.
XV150 5.7"
Resistive-Touch, VGA 640 x 480 Pixel, Recommended flush mounting cutout 198 x 142 MM
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
Number of colours: 64 k Colours
1 x Ethernet 10/100 Mbps
1 x USB host 2.0
1 x USB device
Can be fitted by user with article no. 142581 LIC-PLC-MXP-
COMPACT
✓
✓
✓
-
✓
✓
-
-
✓
✓ ✓ -
Including ✓
-
✓
✓
✓
✓
✓
-
✓
✓ -
XV150 8.4"
Resistive-Touch, VGA 640 x 480 Pixel, Recommended flush mounting cutout 261 x 194 MM
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
Number of colours: 64 k Colours
1 x Ethernet 10/100 Mbps
1 x USB host 2.0
1 x USB device
Can be fitted by user with article no. 142581 LIC-PLC-MXP-
COMPACT
✓
✓
✓
-
✓
✓
-
-
✓
✓ ✓ -
Including ✓
-
✓
✓
✓
✓
✓
-
✓
✓ -
XV150 10.4"
Resistive-Touch, VGA 640 x 480 Pixel, Recommended flush mounting cutout 329 x 238 MM
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
Number of colours: 64 k Colours
1 x Ethernet 10/100 Mbps
1 x USB host 2.0
1 x USB device
Can be fitted by user with article no. 142581 LIC-PLC-MXP-
COMPACT
✓
✓
✓
-
✓
✓
-
-
✓
✓ ✓ -
Including ✓
-
✓
✓
✓
✓
✓
-
✓
✓ -
-
-
-
✓
-
-
✓
✓
-
-
-
-
-
-
✓
✓
-
-
✓
-
✓
-
-
✓
-
-
✓
-
-
-
-
✓
-
-
✓
-
✓
-
-
✓
-
-
✓
-
-
-
-
✓
XV-152-D0-57TVR-10
XV-152-D4-57TVR-10
XV-152-D6-57TVR-10
XV-152-D8-57TVR-10
XV-152-D6-57TVRC-10
XV-152-D8-57TVRC-10
XV-152-E6-57TVRC-10
XV-152-E8-57TVRC-10
XV-152-D0-84TVR-10
XV-152-D4-84TVR-10
XV-152-D6-84TVR-10
XV-152-D8-84TVR-10
XV-152-D6-84TVRC-10
XV-152-D8-84TVRC-10
XV-152-E6-84TVRC-10
XV-152-E8-84TVRC-10
XV-152-D0-10TVR-10
XV-152-D4-10TVR-10
XV-152-D6-10TVR-10
XV-152-D8-10TVR-10
XV-152-D6-10TVRC-10
XV-152-D8-10TVRC-10
XV-152-E6-10TVRC-10
XV-152-E8-10TVRC-10
150601
150602
150603
150604
150605
150606
166702
166703
150607
150608
150609
150610
150611
150612
166704
166705
150525
150526
150527
150528
150529
150600
166700
166701
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 40 Donnerstag, 7. April 2016 12:02 12
XV150
HMI-PLC touch display with PLC
HMI-PLC touch display with PLC
PLC-licence
40
Built-in interfaces
EATON CORPORATION CA08103003Z-EN
Part no.
XV150 5.7"
Resistive-Touch, VGA 640 x 480 Pixel, Recommended flush mounting cutout 198 x 142 MM
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
Number of colours: 64 k Colours
1 x Ethernet 10/100 Mbps
1 x USB host 2.0
1 x USB device
Can be fitted by user with article no. 142581 LIC-PLC-MXP-
COMPACT
✓
✓
✓
-
✓
✓
-
-
✓
✓ ✓ -
Including ✓
-
✓
✓
✓
✓
✓
-
✓
✓ -
XV150 8.4"
Resistive-Touch, VGA 640 x 480 Pixel, Recommended flush mounting cutout 261 x 194 MM
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
Number of colours: 64 k Colours
1 x Ethernet 10/100 Mbps
1 x USB host 2.0
1 x USB device
Can be fitted by user with article no. 142581 LIC-PLC-MXP-
COMPACT
✓
✓
✓
-
✓
✓
-
-
✓
✓ ✓ -
Including ✓
-
✓
✓
✓
✓
✓
-
✓
✓ -
XV150 10.4"
Resistive-Touch, VGA 640 x 480 Pixel, Recommended flush mounting cutout 329 x 238 MM
Windows CE 5.0 (licence incl.), Approvals cUL (UL508)
Slots for SD card: 1
Number of colours: 64 k Colours
1 x Ethernet 10/100 Mbps
1 x USB host 2.0
1 x USB device
Can be fitted by user with article no. 142581 LIC-PLC-MXP-
COMPACT
✓
✓
✓
-
✓
✓
-
-
✓
✓ ✓ -
Including ✓
-
✓
✓
✓
✓
✓
-
✓
✓ -
-
-
✓
-
✓
-
-
✓
-
-
✓
-
✓
-
-
✓
-
-
-
✓
-
-
✓
✓
-
-
✓
-
-
-
-
✓
-
-
✓
-
-
-
-
✓
-
-
-
-
-
-
✓
✓
XV-152-D0-57TVR-10
XV-152-D4-57TVR-10
XV-152-D6-57TVR-10
XV-152-D8-57TVR-10
XV-152-D6-57TVRC-10
XV-152-D8-57TVRC-10
XV-152-E6-57TVRC-10
XV-152-E8-57TVRC-10
XV-152-D0-84TVR-10
XV-152-D4-84TVR-10
XV-152-D6-84TVR-10
XV-152-D8-84TVR-10
XV-152-D6-84TVRC-10
XV-152-D8-84TVRC-10
XV-152-E6-84TVRC-10
XV-152-E8-84TVRC-10
XV-152-D0-10TVR-10
XV-152-D4-10TVR-10
XV-152-D6-10TVR-10
XV-152-D8-10TVR-10
XV-152-D6-10TVRC-10
XV-152-D8-10TVRC-10
XV-152-E6-10TVRC-10
XV-152-E8-10TVRC-10
150601
150602
150603
150604
150605
150606
166702
166703
150607
150608
150609
150610
150611
150612
166704
166705
150525
150526
150527
150528
150529
150600
166700
166701
Article no.
CA08103003Z_MOEM2015-EN.book Seite 41 Donnerstag, 7. April 2016 12:02 12
HMI PLC touch display
PLC-licence Built-in interfaces Part no.
XV300
HMI PLC touch display
Article no.
XV-303 Front installation
Windows Embedded Compact 7 Pro, Approvals: cUL 61010-2-201
Slots for SD card: 1
Resolution: WSVGA 1024 x 600 Pixel
Capacitive multi-touch technology (PCT), Number of colours: 16 mil.
Front type: Anti-glare tempered glass in plastic bezel
7"
Can be fitted by user with article no. 181585
LIC-PLC-A
PLC licence inclusive ✓
-
✓
-
✓
-
✓
-
✓
-
-
✓
-
✓
-
✓
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
✓ -
✓
✓
✓
✓
✓
10.1"
Can be fitted by user with article no. 181585
LIC-PLC-A
PLC licence inclusive ✓
-
-
✓
✓
-
-
✓
✓
-
-
✓
XV-313 Rear flush mounting
Windows Embedded Compact 7 Pro, Approvals: cUL 61010-2-201
Slots: for SD card: 1
Resolution: WSVGA 1024 x 600 Pixel
Capacitive multi-touch technology (PCT)
Number of colours: 16 mil.
Front type: Anti-glare tempered glass without bezel
7"
PLC licence inclusive ✓ -
-
✓
-
-
✓
-
✓
-
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
✓
-
-
-
-
-
-
✓
-
✓
-
-
✓
-
✓
✓
✓
-
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
✓
-
-
-
-
-
-
✓
-
✓
-
✓
✓
-
-
-
-
✓
✓
✓
✓ ✓ ✓ ✓ -
XV-303-70-B00-A00-1B
XV-303-70-C00-A00-1B
XV-303-70-B02-A00-1B
XV-303-70-C02-A00-1B
XV-303-70-B00-A00-1C
XV-303-70-C00-A00-1C
XV-303-70-B02-A00-1C
XV-303-70-C02-A00-1C
XV-303-70-BE0-A00-1C
XV-303-70-CE0-A00-1C
XV-303-70-BE2-A00-1C
XV-303-70-CE2-A00-1C
XV-303-10-B00-A00-1B
XV-303-10-C00-A00-1B
XV-303-10-B02-A00-1B
XV-303-10-C02-A00-1B
XV-303-10-B00-A00-1C
XV-303-10-C00-A00-1C
XV-303-10-B02-A00-1C
XV-303-10-C02-A00-1C
XV-303-10-BE0-A00-1C
XV-303-10-CE0-A00-1C
XV-303-10-BE2-A00-1C
XV-303-10-CE2-A00-1C
XV-313-70-B00-A00-1C
179659
179660
179663
179664
179661
179662
179665
179666
179667
179668
179669
179670
179647
179648
179651
179652
179649
179650
179653
179654
179655
179656
179657
179658
179671
10.1"
PLC licence inclusive ✓ ✓ ✓ ✓ ✓ ✓ XV-313-10-B00-A00-1C 179672
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 42 Donnerstag, 7. April 2016 12:02 12
XV400
HMI-PLC touch display with PLC
HMI-PLC touch display with PLC
PLC-licence Touch-technology Front type Part no.
Article no.
XV400
Built-in interfaces
- 1 x CAN
- 1 x Ethernet 100base-TX/10base-T
- 1 x RS232
- 1 x USB device
Number of colours: Adjustable: 65536 or 256 colours
Windows CE (license required), CompactFlash card required, Approvals cUL (UL508)
XV400 5.7"
Slots
- for Compact-Flash TMCards: 1
- for communication modules: 1
1 x USB host
QVGA 320 x 240 Pixel, Recommended flush mounting cutout 198 x 142 MM
Can be fitted by user with ✓ article no. 140389 LIC-PLC-MXP-
SMALL
-
✓
-
-
✓
XV400 8.4"
Slots
- for Compact-Flash TMCards: 1
- for communication modules: 1
1 x USB host
VGA 640 x 480 Pixel, Recommended flush mounting cutout 261 x 194 MM
Can be fitted by user with ✓ article no. 140389 LIC-PLC-MXP-
SMALL
-
-
-
✓
✓
-
✓
✓
-
✓
XV-460-57TQB-1-10
XV-460-57TQB-1-50
XV-450-57TQB-1-10
139897
139898
139899
✓ ✓ XV-460-84TVB-1-10 139900
XV400 10.4"
Slots
- for Compact-Flash TMCards: 2
- for communication modules: 2
2 x USB host
VGA 640 x 480 Pixel, Recommended flush mounting cutout 329 x 238 MM
Can be fitted by user with article no. 140390 LIC-PLC-MXP-
MEDIUM
✓
✓ -
-
✓
-
-
✓ -
✓
✓
-
✓
✓
XV-430-10TVB-1-10
XV-440-10TVB-1-10
XV-440-10TVB-1-50
139902
139904
139908
XV400 12.1"
Slots
- for Compact-Flash TMCards: 2
- for communication modules: 2
2 x USB host
SVGA 800 x 600 Pixel, Recommended flush mounting cutout 344 x 262 MM
Can be fitted by user with article no. 140390 LIC-PLC-MXP-
MEDIUM
-
✓
✓
✓ -
-
-
✓
-
✓
-
-
-
✓
✓
✓
✓
✓
-
✓
XV-430-12TSB-1-10
XV-440-12TSB-1-10
XV-460-12TSB-1-10
XV-440-12TSB-1-50
139909
139911
169824
139915
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 42 Donnerstag, 7. April 2016 12:02 12
XV400
HMI-PLC touch display with PLC
HMI-PLC touch display with PLC
PLC-licence Touch-technology Front type Part no.
Article no.
CA08103003Z_MOEM2015-EN.book Seite 43 Donnerstag, 7. April 2016 12:02 12
PLC-licence
XV400
HMI/HMI-PLC touch display with PLC, Visualisation solutions
Touch-technology Front type Part no.
Article no.
XV400
Built-in interfaces
- 1 x CAN
- 1 x Ethernet 100base-TX/10base-T
- 1 x RS232
- 1 x USB device
Number of colours: Adjustable: 65536 or 256 colours
Windows CE (license required), CompactFlash card required, Approvals cUL (UL508)
XV400 5.7"
Slots
- for Compact-Flash TMCards: 1
- for communication modules: 1
1 x USB host
QVGA 320 x 240 Pixel, Recommended flush mounting cutout 198 x 142 MM
Can be fitted by user with ✓ article no. 140389 LIC-PLC-MXP-
SMALL
-
✓
-
-
✓
XV400 8.4"
Slots
- for Compact-Flash TMCards: 1
- for communication modules: 1
1 x USB host
VGA 640 x 480 Pixel, Recommended flush mounting cutout 261 x 194 MM
Can be fitted by user with ✓ article no. 140389 LIC-PLC-MXP-
SMALL
-
-
-
✓
✓
-
✓
✓
-
✓
XV-460-57TQB-1-10
XV-460-57TQB-1-50
XV-450-57TQB-1-10
139897
139898
139899
✓ ✓ XV-460-84TVB-1-10 139900
XV400 10.4"
Slots
- for Compact-Flash TMCards: 2
- for communication modules: 2
2 x USB host
VGA 640 x 480 Pixel, Recommended flush mounting cutout 329 x 238 MM
Can be fitted by user with article no. 140390 LIC-PLC-MXP-
MEDIUM
✓
✓ -
-
✓
-
-
✓ -
✓
✓
-
✓
✓
XV-430-10TVB-1-10
XV-440-10TVB-1-10
XV-440-10TVB-1-50
139902
139904
139908
XV400 12.1"
Slots
- for Compact-Flash TMCards: 2
- for communication modules: 2
2 x USB host
SVGA 800 x 600 Pixel, Recommended flush mounting cutout 344 x 262 MM
Can be fitted by user with article no. 140390 LIC-PLC-MXP-
MEDIUM
-
✓
✓
✓ -
-
-
✓
-
✓
-
-
-
✓
✓
✓
✓
✓
-
✓
XV-430-12TSB-1-10
XV-440-12TSB-1-10
XV-460-12TSB-1-10
XV-440-12TSB-1-50
139909
139911
169824
139915
XV400
Built-in interfaces
- 1 x CAN
- 1 x Ethernet 100base-TX/10base-T
- 1 x RS232
- 1 x USB device
Number of colours: Adjustable: 65536 or 256 colours
Windows CE (license required), CompactFlash card required, Approvals cUL (UL508)
XV400 15"
Slots
- for Compact-Flash TMCards: 2
- for communication modules: 2
2 x USB host
XVGA 1024 x 768 Pixel, Recommended flush mounting cutout 410 x 315 MM
Can be fitted by user with ✓ article no. 140390 LIC-PLC-MXP-
MEDIUM
✓ -
-
✓ -
✓ ✓
✓
XV-460-15TXB-1-10
XV-460-15TXB-1-50
139916
139918
HMI/HMI-PLC touch display with PLC, Visualisation solutions
Description
Communication modules for XV4...
Multiple protocol board MPI
Multiple protocol board
Log board
Log board
Supported protocols
Eaton Suconet
Siemens MPI
Matsushita FP series
Mitsubishi A-Series/F-Series
Omron C-H-K-Series
Telemecanique Unitelway new
See manual for other protocols
Eaton Suconet
Matsushita FP series
Mitsubishi A-Series/F-Series
Omron C-H-K-Series
Telemecanique Unitelway new
See manual for other protocols
Profibus DP-Slave (12 MBaud)
Profibus DP-Master (12 MBaud)
Part no.
COM-MPB2-TP
Article no.
139847
COM-MPB1-TP 139850
COM-PDP-TP
COM-DPM-MC2
139849
139853
42 EATON CORPORATION CA08103003Z-EN Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 44 Donnerstag, 7. April 2016 12:02 12
XVS400
HMI/HMI-PLC touch display with PLC
HMI/HMI-PLC touch display with PLC
PLC-licence Touch-technology Front type Part no.
Article no.
XVS400
Built-in interfaces
- 1 x Ethernet 100base-TX/10base-T
- 1 x RS232
- 1 x PROFIBUS/MPI
- 1 x USB device
Number of colours: Adjustable: 65536 or 256 colours
Windows CE (license required), CompactFlash card required, Approvals cUL (UL508)
XVS400 5.7"
Slots
- for Compact-Flash TMCards: 1
1 x USB host
QVGA 320 x 240 Pixel, Recommended flush mounting cutout 198 x 142 MM
Can be fitted by user with article no.
140389 LIC-PLC-MXP-SMALL
-
✓ -
✓
-
✓
✓
-
✓
XVS-450-57MPI-1-10
XVS-460-57MPI-1-10
139969
139970
XVS400 8.4"
Slots
- for Compact-Flash TMCards: 1
1 x USB host
VGA 640 x 480 Pixel, Recommended flush mounting cutout 261 x 194 MM
Can be fitted by user with article no.
140389 LIC-PLC-MXP-SMALL
XVS400 10.4"
Slots
- for Compact-Flash TMCards: 2
2 x USB host
VGA 640 x 480 Pixel, Recommended flush mounting cutout 329 x 238 MM
Can be fitted by user with article no.
140390 LIC-PLC-MXP-MEDIUM
XVS400 12.1"
Slots
- for Compact-Flash TMCards: 2
2 x USB host
SVGA 800 x 600 Pixel, Recommended flush mounting cutout 344 x 262 MM
Can be fitted by user with article no.
140390 LIC-PLC-MXP-MEDIUM
XVS400 15"
Slots
- for Compact-Flash TMCards: 2
2 x USB host
XVGA 1024 x 768 Pixel, Recommended flush mounting cutout 410 x 315 MM
-
Can be fitted by user with sarticle no.
140390 LIC-PLC-MXP-MEDIUM
✓
-
✓
-
✓
✓
-
-
-
✓
-
✓ -
-
-
-
-
✓ ✓
✓
✓
✓
✓
✓
-
-
✓
✓
✓
XVS-460-84MPI-1-10 139971
XVS-430-10MPI-1-10
XVS-440-10MPI-1-10
XVS-430-12MPI-1-10
XVS-440-12MPI-1-10
XVS-460-15MPI-1-10
139972
139973
139974
139975
139976
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 44 Donnerstag, 7. April 2016 12:02 12
XVS400
HMI/HMI-PLC touch display with PLC
HMI/HMI-PLC touch display with PLC
PLC-licence Touch-technology Front type Part no.
Article no.
XVS400
Built-in interfaces
- 1 x Ethernet 100base-TX/10base-T
- 1 x RS232
- 1 x PROFIBUS/MPI
- 1 x USB device
Number of colours: Adjustable: 65536 or 256 colours
Windows CE (license required), CompactFlash card required, Approvals cUL (UL508)
XVS400 5.7"
Slots
- for Compact-Flash TMCards: 1
1 x USB host
QVGA 320 x 240 Pixel, Recommended flush mounting cutout 198 x 142 MM
Can be fitted by user with article no.
140389 LIC-PLC-MXP-SMALL
-
✓ -
✓
-
✓
✓
-
✓
XVS-450-57MPI-1-10
XVS-460-57MPI-1-10
139969
139970
XVS400 8.4"
Slots
- for Compact-Flash TMCards: 1
1 x USB host
VGA 640 x 480 Pixel, Recommended flush mounting cutout 261 x 194 MM
Can be fitted by user with article no.
140389 LIC-PLC-MXP-SMALL
XVS400 10.4"
Slots
- for Compact-Flash TMCards: 2
2 x USB host
VGA 640 x 480 Pixel, Recommended flush mounting cutout 329 x 238 MM
Can be fitted by user with article no.
140390 LIC-PLC-MXP-MEDIUM
XVS400 12.1"
Slots
- for Compact-Flash TMCards: 2
2 x USB host
SVGA 800 x 600 Pixel, Recommended flush mounting cutout 344 x 262 MM
Can be fitted by user with article no.
140390 LIC-PLC-MXP-MEDIUM
XVS400 15"
Slots
- for Compact-Flash TMCards: 2
2 x USB host
XVGA 1024 x 768 Pixel, Recommended flush mounting cutout 410 x 315 MM
-
Can be fitted by user with sarticle no.
140390 LIC-PLC-MXP-MEDIUM
✓
-
✓
-
✓
✓
-
-
-
✓
-
✓ -
-
-
-
-
✓ ✓
✓
✓
✓
✓
✓
-
-
✓
✓
✓
XVS-460-84MPI-1-10 139971
XVS-430-10MPI-1-10
XVS-440-10MPI-1-10
XVS-430-12MPI-1-10
XVS-440-12MPI-1-10
XVS-460-15MPI-1-10
139972
139973
139974
139975
139976
CA08103003Z_MOEM2015-EN.book Seite 45 Donnerstag, 7. April 2016 12:02 12
XV400
Visualisation solutions
Visualisation solutions
Description
Windows CE licenses
License for Windows CE 5.0 Core, incl. license label
License for Windows CE 5.0 Professional Plus incl. license label
For use with
XV-4…
XVS-4…
XV-4…
XVS-4…
Part no.
LIC-OS-CE50-C
LIC-OS-CE50-PP
Article no.
140406
140408
Memory cards
SD memory card with min. 1 GB
Without operating system
SD memory card with min. 256 MByte
Without operating system
Compact flash with min. 128 MByte
Without operating system
Compact flash with min. 128 MByte
WINDOWS CE 5.0 CORE preinstalled
Windows license, article no. 140406 LIC-OS-CE50-C, required
XV-3…
XV-1..
XV-3…
XV-1..
XV-4…
XVS-4…
XV-4…
XVS-4…
MEMORY-SD-A2-S
MEMORY-SD-A1-S
MEMORY-CF-A1-S
OS-FLASH-A1-C
181638
139807
139528
140368
XV license product certificates
Notes
License product certificate for PLC upgrading
License product certificate for PLC upgrading with COMPACT license label
License product certificate for PLC upgrading with SMALL license label
License product certificate for PLC upgrading with MEDIUM license label
License product certificate 40 points
License product certificate 80 points
XV-3.3-..-...-...-1B
XV-1…-B…
XV-1…-D…
XV-4…-57…
XV-4…-84…
XVS-4…-57…
XVS-4…-84…
XV-4…-10…
XV-4…-12…
XV-4…-15…
XVS-4…-10…
XVS-4…-12…
XVS-4…-15…
XV-1…
XV-4…
XVS-4…
XV-1…
XV-4…
XVS-4…
LIC-PLC-A
LIC-PLC-MXP-COMPACT
LIC-PLC-MXP-SMALL
LIC-PLC-MXP-MEDIUM
LIC-OPT-1ST-LEVEL
LIC-OPT-2ND-LEVEL
181585
142581
140389
140390
140391
140392
Licensing for Panel XV100, XV400 and XVS400
The panels of the device series XV100, XV400 und XVS400 are supplied with license points saved to the device. License points are required to be able to perform certain functions with the device
- XSOFT-CODESYS runtime for the PLC function (not possible with: XV-102-A… and XV-102-H…)
- Galileo runtime for visualization
- Communication (e. g. Ethernet, CANopen, Siemens MPI)
Number of license points supplied with standard devices:
- 140 license points: XV100 (without PLC function), XV400, XVS400
- 240 license points: XV100 with PLC function
Additional license points must be purchased if the license points of the device are not sufficient for the required functions or if the XV panel is to be upgraded with the PLC function. For this you need one or more license certificates. They are:
- License certificates for the PLC function: The LIC-PLC-MXP license certificates are required to activate the PLC function on XSOFT-CODESYS; they contain an appropriate license sticker for the device type, which must be affixed to the device for licensing reasons.
- License certificates for the extended communication with Galileo (LIC-OPT-...)
Determining required license points
Add the required license points by function for visualization and communication options used. Communication options for several devices with the same protocol only have to be counted once. Deduct from this total the number of points already on the device (e.g. 140 points). The difference is the number of the license points that you have to install using license certificates for the communication options (LIC-OPT-…).
Detailed information and examples can be obtained at: www.eaton.eu/XV for XV devices on the “Licensing” tab
Licensing for Panel XV300
If you want to add the PLC function to the XV-3.3-..-...-...-1B panel, you will need to purchase an additional license. To do this, you will need license product certificate LIC-PLC-A. Due to licensing reasons, the license sticker must be affixed to the device.
44 EATON CORPORATION CA08103003Z-EN Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
XP500 industrial touch panel PC
Zoom, scroll, swipe with two fingers – the industrial world can now enjoy the benefits of intuitive ease-of-use as well!
The XP500 series from Eaton, developed especially for the requirements of mechanical and plant engineering, enhances the field of automation with contemporary control interfaces and command methods familiar from consumer electronics. The Projected Capacitive Touch (PCT) technology provides a more intuitive user interface. This includes multitouch functionality, allowing users to press functional buttons on the screen either with multiple fingers on one hand or using two hands.
The devices are being launched onto the market with the following three widescreen display sizes: 10.1", 15.6", and 21.5". Their slim design, featuring a non-reflective glass front, delivers a modern look. In addition, their heavy-duty, scratch-resistant front and their open Windows operating system make these panel IPCs ideal for use in virtually any industrial branch in the field of machine building and plant engineering.
46 www.eaton.eu/xp500
EATON CA08103003Z-EN-INT
XP500
Industrial PC
2 x USB 3.0
RS 485
2 x Ethernet 10/100/1000 Mbps
RS 232
DVI-I
24 VDC
CFast removable storage
High availability guaranteed by the Eaton ProtectMode , even without a UPS.
Thanks to the Eaton Protect Mode and two separate mass memory devices, drive C (internal solid-state drive) can be protected against data corruption and other undesirable changes. Process data can be written to the second mass memory device (CFast memory card). All three device sizes are also available with ATEX Zone 22, Cat. 3D certification.
XP-503
• Elegant, slim design
• Heavy-duty glass front in protective aluminum bezel
• Industrial capacitive multi-touch technology
(PCT)
• Widescreen display
• Tempered glass with anti-reflective coating
• Powder-coated diecast aluminum housing for flush mounting
• Passively cooled
XP‐503‐xx‐A10‐
1.65 GHz dual-core CPU
Powerful integrated graphics processor
4GB DDR3‐RAM
≥ 32 GB of internal flash memory
≥ 4 GB CFast Removable memory
2x Ethernet 10/100/1000 Mbps
2x USB 3.0
1x RS232
1x RS485
1x DVI‐I
Windows Embedded Standard 7
GALILEO Open Runtime License
CE, cUL508 cUL Class 1 Div 2
Display Resolution
10.1" widescreen 1024 x 600
15.6" widescreen 1366 x 768
Fitting dimensions Part no.
Article no.
261 x 164mm
388 x 239mm
21.5" widescreen 1920 x 1080 519 x 313mm
XP‐503‐10‐A10‐A00‐1B
174474
XP‐503‐15‐A10‐A00‐1B
174475
XP‐503‐21‐A10‐A00‐1B
174476
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT 47
48
XN300: The slice card modular I/O system for the machine building industry
Eaton‘s ultra-compact, slice-card-based XN300 modular I/O system features a high channel density plug-in connection system and can be combined with HMI PLC products in order to create the ideal system solution for your applications. The secret? Application-oriented functions that result in lower device costs and make it possible to obtain the perfect system solution while taking up a minimal amount of space.
All this is combined with a sleek design and a convenient installation concept that makes handling easier and allows users to pre-assemble their I/O stations and the components they will be connecting. Moreover, the plug-in terminal system and the way in which signals are clearly identified make commissioning easier and round off the system‘s characteristics, making it the perfect solution for the needs of machine building applications meant for mass production.
www.eaton.eu/xn300
EATON CA08103003Z-EN-INT
4
1
Ideal assistance: XN300 Assist
XN300 Assist provides maximum convenience and outstanding ease of use when planning your systems. For example, the tool will run a plausibility check while you are putting together your system configuration, preventing misconfigurations from the get-go. Moreover, XN300 Assist can be used to generate order lists and device description files (e.g., EDS files) even when offline. And in addition to these offline functions, online functions such as „signal state reading and setting“ can prove invaluable during commissioning and installation.
2
5
3
6
1 Bus connector with multiple contacts
2
Module status LED
3
Individual module label
4
Toolless Top-hat rail mounting
5 Signal LED right next to channel
6
Toolless push-in wiring
7 Plug connector
7
Simple, quick and intuitive
A plug-in connection system and the ability to conveniently split installation work into two different steps (putting together a block and then installing it on a mounting rail) are just two examples of how the XN300 system is unbeatable when it comes to saving time: In fact, its installation can be broken down into perfectly efficient steps that allow for pre-assembly
– and all without the need for any tools!
Moreover, a clear functional layout makes it possible to easily keep track of things despite the modules' high channel density. LEDs are used to show signal states right next to where channels are connected.
7
1
2
3
6
4
17
18
19
20
13
14
15
16
9
10
11
12
1
7
8
5
6
2
3
4
X2
20DI
PF
6
7
8
1
2
3
4
X2
5
16DO
P05
7
8
5
6
1
2
3
4
X2
9
10
11
12
9
10
11
12
13
14
15
16
13
14
15
16
+1
+2
17
18
0V
0V
13
14
15
16
9
10
11
12
+1
+2
M
S
U
C1
2
3
4
X2
5
6
7
8
5
13
14
15
16
9
10
11
12
17
18
24
24
7
8
5
6
1
2
3
4
X2
18PD
P
X2
20DI
PF
13
14
15
16
9
10
11
12
17
18
19
20
R
R
R
R
-
1+
-
2+
-
3+
-
4+
3+
3-
4+
4-
1+
1-
2+
2-
X2
8AIO
U2
9
10
11
12
13
14
15
16
17
18
19
20
1
2
7
8
5
6
3
4
X2
20DI
PCNT
13
14
15
16
9
10
11
12
17
18
19
20
1
2
3
4
X2
5
6
7
8
20DI
PF
13
14
15
16
9
10
11
12
+1
+2
S
U
4DO
RNO
C1
R1
R1
C2
EATON CA08103003Z-EN-INT
1 Gateway
2 Digital input modules
3 Digital output modules
4 Relay modules
5 Analog input/output modules
6 Power distributor
7 End bracket
Other module models
• Digital input/output modules
• Analog input modules
• Analog output modules
• Technology modules
• Power supply modules
49
CA08103003Z_MOEM2015-EN.book Seite 50 Donnerstag, 7. April 2016 12:02 12
I/O system
Modular I/O system XN300
Modular I/O system XN300
Description
XN300 gateway
Digital gateway for CANopen field bus in the form of an XN300 I/O system slice module
Field bus connection CANopen®
Addressing DIP switches
Data transfer rate 10, 20, 50, 125, 250, 500, 800, 1000 kBit/s
Maximum station configuration 32 modules (XN-322) in slice design
System supply 24 V DC
Push-in spring-cage terminal
Approvals: CE, cULus
XN300 power supply modules
Push-in spring-cage terminal
Approvals: CE, cULus
Field potential distributor module
Power distribution with XN-322 slice module in XN300 I/O system, 18 channels, GND.
Part no.
Article no.
XN-312-GW-CAN
178782
Power distribution with XN-322 slice module in XN300 I/O system, 18 channels, VCC.
XN-322-18PD-M
178769
XN-322-18PD-P
178770
Power supply module
The power supply module distributes the supplied power to XN300 system components. The module features nine short-circuit proof outputs (24 VDC/GND) grouped into four power supply groups, with each group being able to handle a max. load of 2 A.
XN-322-4PS-20
178796
XN300 technology modules
Push-in spring-cage terminal
Counter module
Counter module with RS422/TTL inputs for frequencies of up to 125 kHz and 4 digital inputs and 4 digital outputs with 2 A. These modules are particularly useful for reading counter values used in positioning applications.
XN-322-1CNT-8DIO
178795
Interface module
Interface module for interpreting data from two absolute encoders via the RS422 interface, specifically designed with SSI encoders (e.g., absolute linear encoders) in mind. Natural binary and Gray code encoders
(Gray code is internally converted to natural binary) are supported. 32-bit / 125 kHz, 250 kHz, 500 kHz, 1 MHz.
XN-322-2SSI
178773
Weigh module
Weigh slice module for connecting two Wheatstone bridges (strain gauge load cells). With a 24-bit resolution, readings will be available with an accuracy of ±0.035%.
XN-322-2DMS-WM
178793
Motor driver module
Current regulator module for operating a DC motor (brushed motor) with a supply voltage of 12–30 V and a max. motor current of 3.5 A. In addition, this module features two 20 mA / 350 mA (maximum current) LED drivers.
XN-322-1DCD-B35
178794
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 51 Donnerstag, 7. April 2016 12:02 12
XN300 I/O slice modules
Short Description
Digital input cards
Push-in spring-cage terminal
Approvals: CE, cULus
8 digital inputs 24 V DC each, pulse-switching, 5.0 ms
16 digital inputs 24 V DC each, pulse-switching, 5.0 ms
20 digital inputs 24 V DC each, pulse-switching, 5.0 ms
20 digital inputs 24 V DC each, pulse-switching, 0.5 ms
20 digital inputs 24 V DC each, pulse-switching, 2/4 CNT, 25 kHz
20 digital inputs 24 V DC each, negative switching, 5.0 ms
Digital output modules
Push-in spring-cage terminal
Approvals: CE, cULus
8 digital outputs short-circuit proof 24 V DC/0.5 A each, pulse-switching
16 digital outputs short-circuit proof 24 V DC/0.5 A each, pulse-switching
12 digital outputs short-circuit proof 24 V DC/1.7 A each, pulse-switching
Digital input/output modules
Push-in spring-cage terminal
Approvals: CE, cULus
4 digital inputs and 4 digital outputs 24 V DC each, pulse-switching
8 digital inputs and 8 digital outputs 24 V DC each, pulse-switching
8 digital inputs and 8 digital outputs 24 V DC each, pulse-switching, CNT, 25 kHz
Relay modules
Push-in spring-cage terminal
4 digital relay outputs, N/O
Analog input cards
Push-in spring-cage terminal
Approvals: CE, cULus
4 analog resistance inputs, Pt/Ni/KTY/R with 2-wire or 3-wire connection
6 analog inputs, +/-10V, 1 PT/KTY, Uref
8 analog current inputs, 0/4 up to 20 mA
8 analog thermocouple inputs and two KTY inputs
Analog output modules
Push-in spring-cage terminal
Approvals: CE, cULus
8 analog outputs , +/-10 V
Analog input/output modules
Push-in spring-cage terminal
Approvals: CE, cULus
2 analog inputs and 2 analog outputs, +/-10 V, Uref
4 analog inputs and 4 analog outputs, +/-10 V, Uref
2 analog inputs and 2 analog outputs, 0/4 to 20 mA
4 analog inputs and 4 analog outputs, 0/4 to 20 mA
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Part no.
I/O system
XN300 I/O slice modules
Article no.
XN-322-8DI-PD
XN-322-16DI-PD
XN-322-20DI-PD
XN-322-20DI-PF
XN-322-20DI-PCNT
XN-322-20DI-ND
183172
183173
178786
178768
178767
183174
XN-322-8DO-P05
XN-322-16DO-P05
XN-322-12DO-P17
183175
178787
178788
XN-322-8DIO-PD05
XN-322-16DIO-PD05
XN-322-16DIO-PC05
183178
183179
183180
XN-322-4DO-RNO 178779
XN-322-4AI-PTNI
XN-322-7AI-U2PT
XN-322-8AI-I
XN-322-10AI-TEKT
178772
178789
179288
178792
XN-322-8AO-U2 178790
XN-322-4AIO-U2
XN-322-8AIO-U2
XN-322-4AIO-I
XN-322-8AIO-I
183181
178791
183182
178771
XI/ON: The modular I/O system
Ethernet
Whether for controlling movements, measuring temperature or speed, or logging currents and voltagesl the application ranges for remote
I/Os are as extensive as the different applications involved. They are used wherever decentralized signal processing is the essential element of the automation concept.
Thanks to the high modularity of the XI/ON system and the wide range of functions, Eaton is able to offer the right I/O solution for every application. XI/ON: A modular concept with simple handling – adaptable to any application, intelligent and ready for future developments.
52 www.eaton.eu/xion
EATON CA08103003Z-EN-INT
13 mm
CA08103003Z-en-EN_046-051__XI-ON_A4_g.fm Seite 46 Dienstag, 14. Oktober 2014 6:13 18
XI/ON
System overview
System overview
XI/ON ECO gateways and ECO modules
XI/ON ECO completes the XI/ON I/O system with price and space optimized
I/O modules and gateways. The ECO gateways use the CAN, PROFIBUS and
Ethernet bus systems.
• ECO gateways with integrated bus terminating resistors
• Full compatibility with the standard XI/ON system
• No base module required
• High channel density (up to 16 DI/DO on 13 mm width)
• “Push-In” spring-loaded terminals
• Multi-functional slices
• Diagnostics interface
I/Oassistant – the universal configuration and diagnostics tool
The I/Oassistant provides you with a universal tool that offers interactive support with the entire planning and implementation of your XI/ON installation.
The I/Oassistant is integrated in XSOFT-CODESYS.
A project is first of all created and structured on the screen. For this you choose gateways, electronic and base modules as well as the appropriate accessories. The individual stations are then configured offline or online. Once everything is set to your satisfaction, you simply put your installation into operation. The I/Oassistant also automatically generates a parts list for your order.
I/Oassistant checks the station, reads the process data, outputs values and visualizes the diagnostics data of the channel. This enables you to commission your station without a higher-level PLC and ensure that a section of the system is functioning correctly.
4
7
1
2
3
3
5
6
7
1 Gateways
2 Relay modules
3 Coding element
4 Base modules
5 Relay jumpers
6 Cover plate
7 End bracket
8 Power supply modules
9 Analog input cards
10 Digital output modules
11 Analog output modules
12 Technology modules
13 Marker
12 11 10 9 8
4
46
1 Gateways
2 Relay modules
3 Coding element
4 Base modules
5 Relay jumpers
6 Cover plate
7 End bracket
13
8 Power supply modules
9 Analog input cards
10 Digital output modules
11 Analog output modules
12 Technology modules
13 Marker
EATON CORPORATION CA08103003Z-DE-DE
EATON CA08103003Z-EN-INT 53
CA08103003Z_MOEM2015-EN.book Seite 54 Donnerstag, 7. April 2016 12:02 12
XI/ON
ECO modules
ECO modules
Field bus connection Data transfer rate
XI/ON ECO Gateways
Push-In spring-cage terminals
System supply 24 /5 V DC
Approvals CE, cULus
PROFIBUS-DP
(DPV0/DPV1 protocol)
CANopen®
Ethernet (Ethernet-IP protocol)
Ethernet (Modbus-TCP protocol)
9.6 Kbit/s to 12 Mbit/s
1000 Kbit/s, 800 Kbit/s, 500 Kbit/s,
250 Kbit/s, 125 kbit/s, 50 Kbit/s,
20 Kbit/s
10/100 MBit/s
10/100 MBit/s
Channels Rated voltage through supply terminal
U
L
Connection design for field bus
Addressing Part no.
Article no.
Input delay t
Rising edge
μ s
Push-In spring-cage terminals
Push-In spring-cage terminals
2 x RJ45 (Ethernet
Switch)
2 x RJ45 (Ethernet
Switch)
DIP switches
DIP switches
DIP switch, BootP,
DHCP or PGM
DIP switch, BootP,
DHCP or PGM
XNE-GWBR-PBDP
140045
XNE-GWBR-CANOPEN
140044
XNE-GWBR-2ETH-IP
140047
XNE-GWBR-2ETH-MB
152279 t
μ
Falling edge s
Input voltage
High level
U e
H
V
Part no.
Article no.
XI/ON ECO digital input modules
Integrated base module
Approvals CE, cULus
8 24 V DC
16 24 V DC
< 100
< 150
< 200
< 300
11 - 30 V
11 - 30 V
XNE-8DI-24VDC-P
140035
XNE-16DI-24VDC-P
140040
Channels Rated voltage through supply terminal
U
L f
Operating frequency at resistive load
Hz
Utilization factor
% g
XI/ON ECO digital output modules
Integrated base module
Can be connected Resistive loads, Inductive loads, Lamp loads
Approvals CE, cULus
8 24 V DC
16 24 V DC
100
100
100
50 %, max. 4 A
Part no.
Article no.
XNE-8DO-24VDC-0.5A-P
140036
XNE-16DO-24VDC-0.5A-P
140039
Channels Rated voltage through supply terminal
U
L
Measured variables 1)
XI/ON ECO analog input modules
Integrated base module
Approvals CE, cULus
8 (U/I), 4
(PT/NI/R)
24 V DC Voltage, current, temperature
(PT, NI), resistance R
Measurement ranges Measured value representation
-10/0 to +10 V DC
0/4 - 20 mA
PT: -200 - +850 (-328 - +1562)/
-200 - +150 (-328 - +302) °C, (°F)
Ni: -60 - +250 (-76 - +482)/
-60 - +150 (-76 - +302) °C, (°F)
16-bit signed integer
12-bit full range, flush left
Standard/extended range/PA (NE43)
1.5
Limit frequency
(-3 db)
Hz
Part no.
Article no.
XNE-8AI-U/I-4PT/NI
140037
Notes 1) : Platinum sensors: Pt100, Pt500, Pt1000 (as per IEC 751) Nickel sensors: Ni100, Ni1000 (as per DIN 43760)
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 54 Donnerstag, 7. April 2016 12:02 12
XI/ON
ECO modules
ECO modules
Field bus connection Data transfer rate
XI/ON ECO Gateways
Push-In spring-cage terminals
System supply 24 /5 V DC
Approvals CE, cULus
PROFIBUS-DP
(DPV0/DPV1 protocol)
CANopen®
Ethernet (Ethernet-IP protocol)
Ethernet (Modbus-TCP protocol)
9.6 Kbit/s to 12 Mbit/s
1000 Kbit/s, 800 Kbit/s, 500 Kbit/s,
250 Kbit/s, 125 kbit/s, 50 Kbit/s,
20 Kbit/s
10/100 MBit/s
10/100 MBit/s
Channels Rated voltage through supply terminal
U
L
Connection design for field bus
Addressing Part no.
Article no.
Input delay t
Rising edge
μ s
Push-In spring-cage terminals
Push-In spring-cage terminals
2 x RJ45 (Ethernet
Switch)
2 x RJ45 (Ethernet
Switch)
DIP switches
DIP switches
DIP switch, BootP,
DHCP or PGM
DIP switch, BootP,
DHCP or PGM
XNE-GWBR-PBDP
140045
XNE-GWBR-CANOPEN
140044
XNE-GWBR-2ETH-IP
140047
XNE-GWBR-2ETH-MB
152279 t
μ
Falling edge s
Input voltage
High level
U e
H
V
Part no.
Article no.
XI/ON ECO digital input modules
Integrated base module
Approvals CE, cULus
8 24 V DC
16 24 V DC
< 100
< 150
< 200
< 300
11 - 30 V
11 - 30 V
XNE-8DI-24VDC-P
140035
XNE-16DI-24VDC-P
140040
Channels Rated voltage through supply terminal
U
L f
Operating frequency at resistive load
Hz
Utilization factor
% g
XI/ON ECO digital output modules
Integrated base module
Can be connected Resistive loads, Inductive loads, Lamp loads
Approvals CE, cULus
8 24 V DC
16 24 V DC
100
100
100
50 %, max. 4 A
Part no.
Article no.
XNE-8DO-24VDC-0.5A-P
140036
XNE-16DO-24VDC-0.5A-P
140039
Channels Rated voltage through supply terminal
U
L
Measured variables 1)
XI/ON ECO analog input modules
Integrated base module
Approvals CE, cULus
8 (U/I), 4
(PT/NI/R)
24 V DC Voltage, current, temperature
(PT, NI), resistance R
Measurement ranges Measured value representation
-10/0 to +10 V DC
0/4 - 20 mA
PT: -200 - +850 (-328 - +1562)/
-200 - +150 (-328 - +302) °C, (°F)
Ni: -60 - +250 (-76 - +482)/
-60 - +150 (-76 - +302) °C, (°F)
16-bit signed integer
12-bit full range, flush left
Standard/extended range/PA (NE43)
1.5
Limit frequency
(-3 db)
Hz
Part no.
Article no.
XNE-8AI-U/I-4PT/NI
140037
Notes
54
1) : Platinum sensors: Pt100, Pt500, Pt1000 (as per IEC 751) Nickel sensors: Ni100, Ni1000 (as per DIN 43760)
EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 55 Donnerstag, 7. April 2016 12:02 12
XI/ON
ECO modules
ECO modules
Channels Rated voltage through supply terminal
U
L
Measured variables
XI/ON ECO analog output modules
Integrated base module
Approvals CE, cULus
4 24 V DC
Measurement ranges
Voltage, Current -10/0…+10 V DC
0/4 - 20 mA
Measured value representation Part no.
Article no.
16-bit signed integer
12-bit full range, flush left
Standard/extended range/PA
(NE43)
XNE-4AO-U/I
140034
Channels Control mode Pulse duration
XI/ON ECO meter, PWM module
Integrated base module
Rated voltage through supply terminal 24 V DC
Signal evaluation A, B: Pulse and direction; single/double/quadruple rotary transducer
Approvals CE, cULus
PWM (parameters can be defined): 0.01 Hz - 20 kHz
Output Number of pulses : 32 Bit
Operating modes Pulse output: Once, endless
2 Infinite counter, once only count, periodic count
32 Bit/max. 120 s
Resolution
Bit
32
Part no.
Article no.
XNE-2CNT-2PWM
140038
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 56 Donnerstag, 7. April 2016 12:02 12
XI/ON
Standard modules
Standard modules
Field bus connection Data transfer rate Connection design for field bus
XI/ON standard gateways with integrated power supply module
Spring-loaded/screw terminal
System supply 24 /5 V DC
Approvals CE, cULus
PROFIBUS-DP (DPV1 protocol)
CANopen®
9.6 Kbit/s to 12 Mbit/s
DeviceNet
Ethernet (Modbus-TCP protocol)
CANopen®
10 Kbit/s, 20 Kbit/s, 50 Kbit/s,
125 kbit/s, 250 Kbit/s, 500
Kbit/s, 800 Kbit/s, 1000 Kbit/s
125 kbit/s, 250 Kbit/s, 500
Kbit/s
10/100 MBit/s adjustable up to 1 Mbit/s
1 x D-SUB socket,
9-pin
Open style connector
Open style connector
RJ45-bus
Open style connector
Addressing Part no.
Article no.
2 decimal rotary coding switches
XN-GWBR-DPV1
148561
2 decimal rotary coding switch XN-GWBR-CANOPEN
140155
2 decimal rotary coding switch XN-GWBR-DNET
140156
Decimal rotary coding switch,
BootP, DHCP or I/Oassistant
Software
XN-GWBR-MODBUS-TCP
140162
XN-PLC-CANOPEN
140157
Field voltage
U
L
System supply
U sys
V DC
Rated current consumption from module bus
I
MB mA
Maximum system supply current
I
MB
A
Part no.
Article no.
XI/ON Standard power supply module
Base module required
Number of diagnostic bytes: 4
Approvals CE, cULus
24 V DC
24 V DC
120/230 V AC -
-
24 -
≦ 28
≦ 25 -
-
1.5
XN-BR-24VDC-D
140071
XN-PF-24VDC-D
140070
XN-PF-120/230VAC-D
140072
Channels Rated voltage through supply terminal
U
L
Input delay t
Rising edge
μ s t
Falling edge
μ s
Input voltage
High level
U e
H
V
Part no.
Article no.
XI/ON standard digital input modules
Base module required
Approvals CE, cULus
2
4
4
2
2
16
32
24 V DC
24 V DC
120/230 V AC
24 V DC
24 V DC
24 V DC
24 V DC
< 200
< 200
< 20000
< 200
< 200
< 200
< 200
< 200
< 200
< 20000
< 200
< 200
< 200
< 200
11 - 30 V
0 - 5 V
79 - 265 V AC
15 - 30 V
0 - 5 V
15 - 30 V
15 - 30 V
XN-2DI-24VDC-P
140056
XN-2DI-24VDC-N
140057
XN-2DI-120/230VAC
140058
XN-4DI-24VDC-P
140052
XN-4DI-24VDC-N
140059
XN-16DI-24VDC-P
140142
XN-32DI-24VDC-P
140147
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 56 Donnerstag, 7. April 2016 12:02 12
XI/ON
Standard modules
Standard modules
Field bus connection Data transfer rate Connection design for field bus
XI/ON standard gateways with integrated power supply module
Spring-loaded/screw terminal
System supply 24 /5 V DC
Approvals CE, cULus
PROFIBUS-DP (DPV1 protocol)
CANopen®
9.6 Kbit/s to 12 Mbit/s
DeviceNet
Ethernet (Modbus-TCP protocol)
CANopen®
10 Kbit/s, 20 Kbit/s, 50 Kbit/s,
125 kbit/s, 250 Kbit/s, 500
Kbit/s, 800 Kbit/s, 1000 Kbit/s
125 kbit/s, 250 Kbit/s, 500
Kbit/s
10/100 MBit/s adjustable up to 1 Mbit/s
1 x D-SUB socket,
9-pin
Open style connector
Open style connector
RJ45-bus
Open style connector
Addressing Part no.
Article no.
2 decimal rotary coding switches
XN-GWBR-DPV1
148561
2 decimal rotary coding switch XN-GWBR-CANOPEN
140155
2 decimal rotary coding switch XN-GWBR-DNET
140156
Decimal rotary coding switch,
BootP, DHCP or I/Oassistant
Software
XN-GWBR-MODBUS-TCP
140162
XN-PLC-CANOPEN
140157
Field voltage
U
L
System supply
U sys
V DC
Rated current consumption from module bus
I
MB mA
Maximum system supply current
I
MB
A
Part no.
Article no.
XI/ON Standard power supply module
Base module required
Number of diagnostic bytes: 4
Approvals CE, cULus
24 V DC
24 V DC
120/230 V AC -
-
24 -
≦ 28
≦ 25 -
-
1.5
XN-BR-24VDC-D
140071
XN-PF-24VDC-D
140070
XN-PF-120/230VAC-D
140072
Channels Rated voltage through supply terminal
U
L
Input delay t
Rising edge
μ s t
Falling edge
μ s
Input voltage
High level
U e
H
V
Part no.
Article no.
XI/ON standard digital input modules
Base module required
Approvals CE, cULus
2
4
4
2
2
16
32
24 V DC
24 V DC
120/230 V AC
24 V DC
24 V DC
24 V DC
24 V DC
< 200
< 200
< 20000
< 200
< 200
< 200
< 200
< 200
< 200
< 20000
< 200
< 200
< 200
< 200
11 - 30 V
0 - 5 V
79 - 265 V AC
15 - 30 V
0 - 5 V
15 - 30 V
15 - 30 V
XN-2DI-24VDC-P
140056
XN-2DI-24VDC-N
140057
XN-2DI-120/230VAC
140058
XN-4DI-24VDC-P
140052
XN-4DI-24VDC-N
140059
XN-16DI-24VDC-P
140142
XN-32DI-24VDC-P
140147
56 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 57 Donnerstag, 7. April 2016 12:02 12
XI/ON
Standard modules
Part no.
Article no.
Channels Rated voltage through supply terminal
U
L
XI/ON Standard digital output modules
Base module required
Connectable: Resistive loads, Inductive loads, Lamp loads
Approvals CE, cULus
2 24 V DC
2
4
2
2
16
32
24 V DC
120/230 V AC (45 - 65 Hz)
24 V DC
24 V DC
24 V DC
24 V DC f
Operating frequency at resistive load Utilization factor
%
Hz g
5000 (R
LO
< 1 k Ω )
100 (R
LO
< 1 kohm)
-
5000 (R
LO
< 1 k Ω )
1000 (R
LO
< 1 k Ω )
100 (R
LO
< 1 k Ω )
100 (R
LO
< 1 k Ω )
100
100
100 (observe derating)
100
100
100
Max. 10 A (total module current)
XN-2DO-24VDC-0.5A-P
140053
XN-2DO-24VDC-0.5A-N
140060
XN-2DO-120/230VAC-0.5A
140150
XN-2DO-24VDC-2A-P
140055
XN-4DO-24VDC-0.5A-P
140148
XN-16DO-24VDC-0.5A-P
140141
XN-32DO-24VDC-0.5A-P
140161
Channels Measured variables Measurement ranges Measured value representation Limit frequency
(-3 db)
Hz
Part no.
Article no.
XI/ON Standard analog input modules
Base module required
Rated voltage through supply terminal: 24 V DC
Approvals CE, cULus
1 Current
2
1
2
4
Current
Voltage
Voltage
Voltage, Current
0/4 - 20 mA
0/4 - 20 mA
-10/0 to +10 V DC
-10/0 to +10 V DC
-10/0 to +10 V DC
16-bit signed integer
12-bit full range left-justified
16-bit signed integer
12-bit full range left-justified
16-bit signed integer
12-bit signed integer left-justified
12-bit full range left-justified
16-bit signed integer
12-bit full range left-justified
16-bit signed integer
12-bit signed integer, flush-left
> 50
20
200
> 50
200
Channels Measured variables Temperature range Measured value representation
°C, (°F)
XI/ON standard temperature modules
Base module required
Rated voltage through supply terminal: 24 V DC
Approvals CE, cULus
2 Temperature
(Thermocouple) 1)
Notes
2 Temperature (PT,
NI), resistance R 2)
Type B: +100 - +1820 (+212 - +3308)
Type E: -270 - +1000 (-454 - +1832)
Type J: -210 - +1200 (-346 - +2192)
Type K: -270 - +1370 (-454 - +2498)
Type N: -270 - +1300 (-454 - +2372)
Type R: -50 - +1760 (-58 - +3200)
Type S: -50 - +1540 (-58 - +2804)
Type T: -270 - +400 (-454 - +752)
PT: -200 - +850 (-328 - +1562)/-200 - +150 (-328 - +302)
Ni: -60 - +250 (-76 - +482)/-60 - +150 (-76 - +302)
16-bit signed integer
12-bit full range leftjustified
16-bit signed integer
12-bit full range leftjustified
1)
2)
According to DIN IEC 584, Class 1, 2, 3
Platinum sensors: PT100, PT200, PT500, PT1000 (according to DIN IEC 751)
Nickel sensors: Ni100, Ni1000 (according to DIN 43760)
XN-1AI-I(0/4...20MA)
140063
XN-2AI-I(0/4...20MA)
140144
XN-1AI-U(-10/0...+10VDC)
140064
XN-2AI-U(-10/0...+10VDC)
140145
XN-4AI-U/I
140158
Part no.
Article no.
XN-2AI-THERMO-PI
140068
XN-2AI-PT/NI-2/3
140067
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 58 Donnerstag, 7. April 2016 12:02 12
XI/ON
Standard modules
Channels Measured variables
XI/ON Standard analogue output modules
Base module required
Rated voltage through supply terminal: 24 V DC
Approvals CE, cULus
1 Current
2
2
Current
Voltage
Measurement ranges Measured value representation
0/4 - 20 mA
0/4 - 20 mA
-10/0…+10 V DC
16-bit signed integer
12-bit full range left-justified
16-bit signed integer
12-bit full range left-justified
16-bit signed integer
12-bit signed integer left-justified
12-bit full range left-justified
Part no.
Article no.
XN-1AO-I(0/4...20MA)
140065
XN-2AO-I(0/4...20MA)
140146
XN-2AO-U(-10/0...+10VDC)
140066
Contact type art Rated load voltage
XI/ON Standard relay modules
Base module required
Rated voltage through supply terminal: 24 V DC
Connectable sensors: Resistive loads, Inductive loads, Lamp loads
Approvals CE, cULus
2 break contacts 230 V AC, 30 V DC
2 make contacts
2 Changeover contact
230 V AC, 30 V DC
230 V AC, 30 V DC
Maximum continuous current, resistive load Part no.
Article no.
5 A
5 A
5 A
XN-2DO-R-NC
140061
XN-2DO-R-NO
140062
XN-2DO-R-CO
140054
Type Transmission channels
XI/ON Standard interface modules
Base module required
Rated voltage through supply terminal: 24 V DC
Approvals CE, cULus
RS232 RxD, TxD, RTS, CTS
RS 484/RS 422 RxD, TxD
SSI CL, D
Bit transfer rate Cable length RS232 m
Max. 115200 bit/s (parameterizable), default setting: 9600 Bit/s, 7 data bits, odd parity,
2 stop bits
Max. 115200 bit/s (parameterizable), default setting: 9600 Bit/s, 7 data bits, odd parity,
2 stop bits
Max. 1 MHz (parameterizable), default settings: 500 kBit/s max. 15 max. 30 max. 30
Part no.
Article no.
XN-1RS232
140151
XN-1RS485/422
140152
XN-1SSI
140153
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 58 Donnerstag, 7. April 2016 12:02 12
XI/ON
Standard modules
Channels Measured variables
XI/ON Standard analogue output modules
Base module required
Rated voltage through supply terminal: 24 V DC
Approvals CE, cULus
1 Current
2
2
Current
Voltage
Measurement ranges Measured value representation
0/4 - 20 mA
0/4 - 20 mA
-10/0…+10 V DC
16-bit signed integer
12-bit full range left-justified
16-bit signed integer
12-bit full range left-justified
16-bit signed integer
12-bit signed integer left-justified
12-bit full range left-justified
Part no.
Article no.
XN-1AO-I(0/4...20MA)
140065
XN-2AO-I(0/4...20MA)
140146
XN-2AO-U(-10/0...+10VDC)
140066
Contact type art Rated load voltage
XI/ON Standard relay modules
Base module required
Rated voltage through supply terminal: 24 V DC
Connectable sensors: Resistive loads, Inductive loads, Lamp loads
Approvals CE, cULus
2 break contacts 230 V AC, 30 V DC
2 make contacts
2 Changeover contact
230 V AC, 30 V DC
230 V AC, 30 V DC
Maximum continuous current, resistive load Part no.
Article no.
5 A
5 A
5 A
XN-2DO-R-NC
140061
XN-2DO-R-NO
140062
XN-2DO-R-CO
140054
Type Transmission channels
XI/ON Standard interface modules
Base module required
Rated voltage through supply terminal: 24 V DC
Approvals CE, cULus
RS232 RxD, TxD, RTS, CTS
RS 484/RS 422 RxD, TxD
SSI CL, D
Bit transfer rate Cable length RS232 m
Max. 115200 bit/s (parameterizable), default setting: 9600 Bit/s, 7 data bits, odd parity,
2 stop bits
Max. 115200 bit/s (parameterizable), default setting: 9600 Bit/s, 7 data bits, odd parity,
2 stop bits
Max. 1 MHz (parameterizable), default settings: 500 kBit/s max. 15 max. 30 max. 30
Part no.
Article no.
XN-1RS232
140151
XN-1RS485/422
140152
XN-1SSI
140153
58 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 59 Donnerstag, 7. April 2016 12:02 12
Selection aids
XI/ON
Selection aids
Electronic modules
Analog input cards
XN-1AI-I(0/4...20MA)
XN-2AI-I(0/4...20MA)
XN-1AI-U(-10/0...+10VDC)
XN-2AI-U(-10/0...+10VDC)
XN-2AI-PT/NI-2/3
XN-2AI-THERMO-PI
XN-4AI-U/I
XNE-8AI-U/I-4PT/NI 1)
Analog output modules
XN-1AO-I(0/4...20MA)
XN-2AO-I(0/4...20MA)
XN-2AO-U(-10/0...+10VDC)
XNE-4AO-U/I 1)
Technology modules
XN-1RS232
XN-1RS485/422
XN-1SSI
XNE-1SWIRE 1)
XNE-2CNT-2PWM 1)
Power supply modules
XN-BR-24VDC-D
XN-PF-24VDC-D
XN-PF-120/230VAC-D
Notes
Digital input cards
XN-2DI-24VDC-P
XN-2DI-24VDC-N
XN-2DI-120/230VAC
XN-4DI-24VDC-P
XN-4DI-24VDC-N
XN-16DI-24VDC-P
XN-32DI-24VDC-P
XNE-8DI-24VDC-P 1)
XNE-16DI-24VDC-P 1)
Digital output modules
XN-2DO-24VDC-0.5A-P
XN-2DO-24VDC-0.5A-N
XN-2DO-24VDC-2A-P
XN-2DO-120/230VAC-0.5A
XN-4DO-24VDC-0.5A-P
XN-16DO-24VDC-0.5A-P
XN-32DO-24VDC-0.5A-P
XNE-8DO-24VDC-0.5A-P 1)
XNE-16DO-24VDC-0.5A-P 1)
Relay modules
XN-2DO-R-NC
XN-2DO-R-NO
XN-2DO-R-CO
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Complete assortment -> www.eaton.eu/ecat
1)
2)
3)
No base module required
Base modules for gateway power supply
Base modules for bus refreshing within the station
EATON CA08103003Z-EN-INT
●
●
●
● 2)
●
●
● 3) ● 2)
●
●
● 3)
Compact and modular PLCs
The compact PLCs XC152 facilitate cost-effective solutions of automation tasks using their computing power, the SmartWire-DT interface as well as a whole range of further interfaces.
An important feature is their ability to be integrated in modern communication concepts. Innovative solutions can be created thanks to the possibility to exchange data with OPC clients via the Ethernet interface and the integrated web server.
The compact class with the EC4P controllers now offer the performance of a PLC in the housing of the renowned easy control relay. This enables the convenient creation of solutions for small and medium-sized control tasks.
The XC100 and XC200 modular PLCs stand out on account of their highly scalable design. Different CPU performance classes and a wide range of expansion modules are available.
www.eaton.eu/xc152
www.eaton.eu/ec4p
www.eaton.eu/xc
60 EATON CA08103003Z-EN-INT
1
XC152 – Compact PLC
The compact PLCs combine PLC performance with a range of communication interfaces.
• OS: Windows CE 5
• Processor: RISC CPU, 32 bit, 400 MHz
• USB device, USB-Host
• Ethernet interface
• Communication interface depending on the type: RS232, RS485,
Profibus/MPI and CANopen
• SmartWire-DT interface depending on the type
• Program, data and retain variable memory: 64MB
• External memory: 1 x SD card
• Programming: CODESYS
• Web server: CODESYS
• Target visualization: GALILEO/CODESYS (remotely viewable)
1
2
1 Compact PLCs XC152
2 SD-Memory Card
Built-in interfaces Application / marker / retain data
KByte
Part no.
Article no.
XC compact PLCs
24 V DC power supply
Slot for memory card
RUN/STOP switch and LED displays
OPC Server
WEB server
Remote Server
Approvals: CE, cULus
Compact PLC XC152
-
-
✓
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
✓
✓
-
✓
-
✓
✓
-
✓
-
✓
✓
✓
✓
-
-
✓
-
✓
64 MB / 4 KB / 32 KB
64 MB / 4 KB / 32 KB
64 MB / 4 KB / 32 KB
64 MB / 4 KB / 32 KB
64 MB / 4 KB / 32 KB
EATON CA08103003Z-EN-INT
XC-152-D8-11
167849
XC-152-E3-11
167850
XC-152-E6-11
167851
XC-152-E8-11
167852
XC-152-D6-11
167855
61
CA08103003Z_MOEM2015-EN.book Seite 62 Donnerstag, 7. April 2016 12:02 12
Compact PLCs
System overview
System overview
3
2
2
4
Moeller® series
1
DEL AL
T T
ESC
9
10
ESC
10
11
11
1
6
7
5
9
11
6
8
7
1 Compact PLC EC4P
2 Display/operating unit MFD-80-B
3 MFD-CP4-CO CANopen® connection
4 Power supply unit/communication module, including connection cable for EC4P
5 EASY202-RE output expansion
EATON CA08103003Z-EN-INT
6 EASY410... I/O expansion, digital
7 EASY6... I/O expansion, digital
8 EASY200-EASY Coupling module
9 CANopen® expansion EC4E-221-…6
10 EU4A-MEM-CARD1 memory card
11 EASY-LINK-DS bus connector plug
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 63 Donnerstag, 7. April 2016 12:02 12
Compact PLCs
Moeller® series
EC4P
Inputs
Digital Of which can be used as analog
Compact PLC EC4P
Expandable: Inputs/outputs and bus systems
Individual laser inscription possible with EC4-COMBINATION-*
Supply voltage 24 V DC
UL/CSA approvals
DNV, GL, ABS, BV, LR shipping classifications easyNet/CANopen® on board
12
12
12
4
4
4
12
12
12
12
12 easyNet/CANopen® and Ethernet on board
12
12
4
4
4
4
4
4
4
12
12
12
12
12
12
Memory card
Adapter with at least 128 MByte memory card
4
4
4
4
4
4
-
6
-
6
-
-
6
6
-
6
6
-
-
-
6
6
Outputs
Relay 10 A
(UL)
Inputs
Digital
Outputs
Relay 10 A (UL)
Expansions usable via CANopen®
6
6 -
4
Transistor
-
-
8
8
8
-
-
8
-
-
8
-
8
-
8
8
Transistor
-
4
Analog
-
-
1
-
-
1
1
1
1
1
-
1
-
-
-
1
24 V DC
24 V DC
Display & keypad
Supply voltage
-
✓
✓
-
✓
-
-
✓
-
-
✓
-
✓
-
✓
✓
Part no.
Part no.
EC4E-221-6D4R1
EC4E-221-6D4T1
EC4P
Article no.
EC4P-221-MTXD1
EC4P-221-MTXX1
EC4P-221-MRXD1
EC4P-221-MRXX1
EC4P-221-MTAD1
EC4P-221-MTAX1
EC4P-221-MRAD1
EC4P-221-MRAX1
EC4P-222-MTXD1
EC4P-222-MTXX1
EC4P-222-MRXD1
EC4P-222-MRXX1
EC4P-222-MTAD1
EC4P-222-MTAX1
EC4P-222-MRAD1
EC4P-222-MRAX1
EU4A-MEM-CARD1
106399
106400
106401
106402
106403
106404
106405
106406
106391
106392
106393
106394
106395
106396
106397
106398
106409
Article no.
114296
114297
More digital and analog expansions → Page 78
Description
Remote text display
Display/operating unit
Monochrome display 132 × 64 pixels with switchable backlight
Removable Titan front frame
Custom laser inscriptions possible with MFD-COMBINATION (article no. 2010801) product
IP65
With keypad
With Eaton company logotype
NEMA type 3R; NEMA type 12; NEMA type 4x together with MFD-XM-80 protective diaphragm
With keypad
Without Eaton company logotype
NEMA type 3R; NEMA type 12; NEMA type 4x together with MFD-XM-80 protective diaphragm
CANopen® connection for multi-function display
Communication module with CANopen® interface
Automatic baud rate setting up to 1 Mbaud
Up to 64 display pages can be saved
For use with display/operating unit MFD-80-B(-X) and connection cable EU4A-RJ45-CAB2
Supply voltage 24 V DC
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Part no.
MFD-80-B
MFD-80-B-X
MFD-CP4-CO
Article no.
265251
284905
115736
CA08103003Z_MOEM2015-EN.book Seite 64 Donnerstag, 7. April 2016 12:02 12
Modular PLCs
System overview
System overview
4
2
1
5
3
5
4
7
3
6
6
6
1 Modular PLCs XC100/XC200
2 Battery
3 Memory card
4 Rack
5 XI/OC I/O and communications modules
6 XI/OC terminal block (screw or spring-cage terminal)
7 XC121 expandable compact PLC
8 I/O expansion for XC121
6
4
8
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z-en-EN_064-067__Modulsteuerung+EC4P_A4_g.fm Seite 65 Mittwoch, 13. April 2016 8:52 08
XC100, XC200, XC121
Digital input count
Quantity of outputs
Built-in interfaces
Modular PLCs
XC100, XC200, XC121
Cycle time for 1 k of instructions
(Bit, Byte) ms
Application/ marker/retain data
KByte
Integrated
Web server
Part no.
Article no.
Modular PLCs
24 V DC power supply
Can be locally expanded with 15 XI/OC modules and remotely extendable
Slot for memory card
RUN/STOP switch and LED displays
UL/CSA approval
The following accessory equipment is required: terminal clamps, module rack, battery
Modular PLC XC-CPU101
Digital: 8; of which usable as interrupt: 4
Transistor:
6
✓ -
✓ -
-
-
✓ -
✓ -
-
✓ ✓ -
✓ ✓ -
< 0.5
< 0.5
< 0.5
< 0.5
Modular PLC XC-CPU201
Digital: 8; of which usable as interrupt: 6
Transistor:
6
✓ ✓ ✓ -
✓ ✓ ✓ -
✓ ✓ ✓ -
✓ ✓ ✓ -
< 0.15
< 0.15
< 0.15
< 0.15
Modular PLC XC-CPU202
Digital:8; of which usable as interrupt: 6
Transistor:
6
✓ ✓ ✓ ✓ < 0.03
64 KB/4 KB/
4 KB
128 KB/8 KB/
8 KB
128 KB/8 KB/
8 KB
256 KB/8 KB/
8 KB
No
No
No
No
XC-CPU101-C64K-8DI-6DO
262152
XC-CPU101-C128K-8DI-6DO
262146
XC-CPU101-FC128K-8DI-6DO
289169
XC-CPU101-C256K-8DI-6DO
274399
256 KB/16 KB/
32 KB
256 KB/16 KB/
32 KB
2 MB/16 KB/
32 KB
2 MB/16 KB/
32 KB
No
Yes
No
Yes
XC-CPU201-EC256K-8DI-6DO
262155
XC-CPU201-EC256K-8DI-6DO-XV
262156
XC-CPU201-EC512K-8DI-6DO
262157
XC-CPU201-EC512K-8DI-6DO-XV
262158
4 MB/16 KB/
32 KB
Yes XC-CPU202-EC4M-8DI-6DO-XV
134238
Modular PLC XC-CPU121
Can be locally expandable with I/O module XIO-EXT-121-1
244 kByte data memory shipping classification: DNV,
LR, BV, GL, ABS
✓ ✓ ✓
I/O Expansion for XC-CPU121
Inputs expansion (number)
Digital: 10; of which can be used as interrupts: 6; analog: 6 (0 - 10V:
2 or 0 - 20 mA: 2 or Pt100: 2)
Digital: An additional 8 (also usable as outputs)
Outputs expansion (number)
Digital: 8 (also usable as inputs)
Analog: 2 (0 - 10 V)
-
< 0.3
-
256 KB/16 KB/
8 KB
No XC-CPU121-2C256K
290446
XIO-EXT121-1
290450
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 66 Donnerstag, 7. April 2016 12:02 12
I/O expansions
XI/OC
XI/OC
Description
I/O expansions XI/OC
Compact I/O system for connection to XC100/200 Modular PLCs
XC100/200 expandable with up to 15 XI/OC modules
Optionally, screw terminals or spring-loaded terminals for digital/analog modules
UL/CSA approvals
Analog modules Inputs
8 Inputs 4 - 20 mA
Inputs
8 voltage input 0 - 10 V
Inputs
8 voltage inputs, ±10 V
Inputs
4 inputs for temperature monitoring, Pt100/1000
Inputs
4 inputs for thermocouples
Type K, J, B, N, E, R, S, T
Outputs
2 outputs, ±10 V
Outputs
2 Outputs 0 - 10 V
2 outputs 4 - 20 mA
Outputs
4 Outputs 0 - 10 V
Digital modules
Combination modules
2 Inputs and 1 Output 0 - 10 V
1 ms conversion time
Combination modules
2 Inputs and 1 Output 0 - 10 V, 0 - 20 mA
1 ms conversion time individual changeover
Combination modules
4 Inputs und 2 Outputs 0 - 10 V
1 ms conversion time
Combination modules
4 Inputs and 2 Outputs 0 - 10 V, 0 - 20 mA
1 ms conversion time individual changeover
8 inputs, 24 V DC
16 inputs, 24 V DC
32 inputs, 24 V DC
Counter modules
Communication modules
8 outputs, 24 V DC, 0.3 A
12 relay outputs
16 outputs, 24 V DC, 0.3 A
16 outputs, 24 V DC, 0.8 A short-circuit proof
16 connections, 4 inputs, 12 freely parameterizable as inputs/outputs, 24 V DC outputs
0.5 A
32 outputs, 24 V DC, 0.2 A
1 input up to 100 kHz, (24 V DC, 5 V DC)
2 digital transistor outputs
Optocoupled, 24 V DC
30 pole connector required for counter module
2 inputs up to 100 kHz, (24 V DC or 5 V diff), 2 inputs up to 100 kHz, (24 V DC or 5 V diff),
4 digital transistor outputs, optocoupled, 24 V DC, 30 pole connector required for counter module
2 incremental encoders up to 400 kHz, 5 V DC, 2 analog outputs, ±10 V
PROFIBUS-DP master module
PROFIBUS DP slave module
Suconet K master module
Serial interface RS232C, RS485, RS422
Modes of operation: Transparent mode MODBUS Master/Slave SUCOM-A
Suconet-K slave
Serial interface RS232C, RS485, RS422
Modes of operation: Transparent mode MODBUS Master/Slave SUCOM-A
DNP3-Protocol
Part no.
XIOC-8AI-I2
XIOC-8AI-U1
XIOC-8AI-U2
XIOC-4T-PT
XIOC-4AI-T
XIOC-2AO-U2
XIOC-2AO-U1-2AO-I2
XIOC-4AO-U1
XIOC-2AI-1AO-U1
XIOC-2AI-1AO-U1-I1
XIOC-4AI-2AO-U1
XIOC-4AI-2AO-U1-I1
XIOC-8DI
XIOC-16DI
XIOC-32DI
XIOC-8DO
XIOC-12DO-R
XIOC-16DO
XIOC-16DO-S
XIOC-16DX
XIOC-32DO
XIOC-1CNT-100KHZ
XIOC-2CNT-100KHZ
XIOC-2CNT-2AO-INC
XIOC-NET-DP-M
XIOC-NET-DP-S
XIOC-NET-SK-M
XIOC-SER
XIOC-TC1
Article no.
262405
281544
257891
257892
267411
257894
257897
257896
257895
262322
267413
257906
257907
262417
257908
286419
289982
267191
135265
257904
257902
257903
262409
281545
262549
257899
257900
257901
289933
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 67 Donnerstag, 7. April 2016 12:02 12
XI/OC
Description
Terminations
One 18 pole terminal plug is required for each digital and analog module as well as XC modular PLCs.
18 pole terminal connector with spring-cage terminals for digital or analog I/O
-
For use with
18-pin terminal connector with screw terminals for digital or analog I/O
-
30 pole connector for counter module, with 4 m cable
Part no.
XIOC-TERM-18T
XIOC-TERM-18S
XIOC-1CNT-100KHZ
XIOC-2CNT-100KHZ
XIOC-TERM30-CNT4
Accessories
XI/OC
Article no.
258104
258102
262248
40 pole connector for digital module, with 4 m cable XIOC-32DI
XIOC-32DO
XIOC-TERM32 267414
Racks
Add-on functions
Basic rack for mounting XC100/200 on top-hat rail, expandable
Width: 2 slots for controller
Expander rack for mounting XI/OC modules on top-hat rail, expandable
Width: 2 slots for controller
Basic rack for mounting XC100/200 on top-hat rail, expandable
Width: 3 slots for controller and one XI/OC module
Expander rack for mounting XI/OC modules on top-hat rail, expandable
Width: 3 slots for XI/OC modules
Expander rack for mounting XI/OC modules on top-hat rail, expandable
Width: 3 slots for XI/OC modules
Note: Module rack for expansion with up to 15 modules, must be plugged into the 6th slot
-
-
-
For storage of programs, data, recipes
512 MByte
For storage of programs, data, recipes
256 MByte
-
-
For back-up of real-time clock and retentive data
XIOC-BP-XC
XIOC-BP-2
XIOC-BP-XC1
XIOC-BP-3
XIOC-BP-EXT
XT-MEM-MM512M
XT-MEM-MM32M
138257
262731
XT-CPU-BAT1
260792
260794
260793
260795
274291
256209
Empty module to cover free XI/OC slots XIOC-NOP 288894
System overview
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
easyRelay control relays
MFD-Titan multi-function display
The easy500/easy700/800 control relays as well as the MFD-Titan multi-function display come with a full range of technical resources to implement applications for industrial and building automation, machine building or plant construction. A host of different device versions with various functions, voltage types, expansion and networking options are available for implementing the right solution. As well as offering the main functions of the easy500/easy700 such as multi-function timing relays, counters, analog value comparators, time switches etc., the easy800 and
MFD-Titan offer a host of function blocks such as PID controllers, maths and value scaling function blocks and many more. The MFD-Titan also offers user-friendly operator and visualization options such as button functions, bitmaps or bar graphs as well as text displays, value entry and display functions. Protection to IP65 means that the display can be used in aggressive environments.
www.eaton.eu/easy
www.eaton.eu/mfd
68 EATON CA08103003Z-EN-INT
S1
K3
K1 S4 S6
S5
K3
K1 K2 K3 ea s y500
For small-scale applications with up to 12 I/O:
• 1:1 electronic circuit diagram entry
• Circuit diagram entry directly on the device possible
• 128 rungs with 3 contacts each and 1 coil in series
• Functions such as multi-function timing relays, impulse relays, counters, analog value comparators, week and year time switches, value entry, value display...
• Connection possible to Ethernet (programming and OPC functionality) ea s y700
For solving medium-sized control tasks up to 40 I/O:
• Full functional range of an easy500
• 128 rungs with 3 contacts each and 1 coil in series
• Local and remote expansion possible for flexibility in the application
• Connection possible to standard bus systems (Profibus, CANopen, Device-
Net, Asi) and Ethernet (programming and OPC functionality)
U
U
U t t t
22.5mm
ea s y800
Ideal for large open-loop and closed-loop control tasks with up to 328 I/O:
• Full functional range of an easy700
• A host of additional functions such as PID controller, maths functions, pulse width modulation, value scaling, high-speed counters (5 kHz),…
• 256 rungs with 4 contacts each and 1 coil in series
• Digital and analog expandability
• Integrated communication via easyNet (up to 8 stations – up to 1000 m)
• Connection possible to standard bus systems (Profibus, CANopen, Device-
Net, Asi) and Ethernet (programming and OPC functionality) ea s y800 with SmartWire-DT
Combines the functions of an easy800 with the direct connection to the communication system for switchgear SmartWire-DT (SW-DT):
• Exchange of data as well as power supply for the SmartWire-DT devices and contactors via the communication system SmartWire-DT
• Up to 99 SmartWire-DT devices in total with up to 166 inputs/outputs can be connected
• ea s yNet as well as 4 additional fast inputs, 2 of which can be used as fast
outputs
• Serial interface for programming or for connection of a remote text display or touch panel or for connection to the Ethernet
MFD-Titan
Combines the functions of an easy800 with user-friendly visualization for largescale applications with more than 300 I/O:
• Display, operation, open and closed-loop control as well as communication in a single device
• Fast and easy to install in 22.5 mm standard fixing holes
• I/O modules for direct temperature measuring (Pt100 / Ni1000)
• Individual laser inscription of devices, for example with own company logo
• Digital and analog expandability
• Communication via easyNet possible (up to 8 stations – up to 1000 m)
• Connection possible to standard bus systems (Profibus, CANopen, Device-
Net, Asi) and Ethernet (programming and OPC functionality)
EATON CA08103003Z-EN-INT 69
Download easyApps from
Ethernet easyNet easy800
Packaging
Machine
SAFETY GATE 4
OPEN easySafety
EASY802-DC-SWD / EASY806-DC-SWD
In addition to the easy800 features with which the industry is already familiar, these two control relays feature an integrated
SmartWire-DT master. This means that the SmartWire-DT line can be configured by simply pressing a button. After this,
SmartWire-DT module switching states, status messages, motor load currents, and diagnostic data can all be easily processed in the corresponding circuit diagram. On top of the functionalities featured by the EASY802-DC-SWD, the
EASY806-DC-SWD comes with an additional 4 fast inputs
(5 kHz), 2 of which can also be configured as fast outputs
(5 kHz) (24 VDC, 0.1 A transistor). Finally, in addition to this extra I/O, the EASY806-DC-SWD can be connected to easyNet.
easySoft-Basic / easySoft-Pro
This programming software is used to program the various easyRelay output classes, as well as the MFD-Titan. To do so, the corresponding circuit diagram is created in the form of a ladder diagram with the use of straightforward dragging and dropping. Moreover, the software programs feature simulation, real-time communication, and documentation options. On top of the functions available in easySoft-
Basic, easySoft-Pro features a screen editor that can be used to create screens for the MFD-Titan. The integrated
SmartWire-DT Assist program is used to integrate the
SmartWire-DT line into the program. Finally, the easySoft-Pro
CD comes with a free OPC server that makes it possible to connect to higher-level computer systems (OPC clients) in a standardized manner. Both software programs can be installed in 13 languages.
Bluetooth-Adapater and easyApps for Android Smartphones
Commissioning and operation of machines and equipment is now easier than ever – thanks to the Bluetooth adapter and easyApps. The free easyRemote Display App offers convenient access for Android smartphones to all available display and operating functions on the easy800 – almost like working on the control relay itself. The easyParameter App allows for customization of individual smartphone user interfaces. The administrator has flexibility in adjusting the user interface for the app user and determines which parameters can be read and modified from the smartphone. Thanks to the practical
Bluetooth adapter, Android smartphones and easy800 can communicate directly via Bluetooth. It is also used for communications between the control relay and the computer.
up to 8 easyNet devices, up to 1000m
COM easy800
Timer
Set: 15.00sec
Act: 04.34sec
- on delay -
70 EATON CA08103003Z-EN-INT
Remote text display
For display and operation in the control panel door, on the machine or on the operator panel up to 5 m from the basis unit. This makes it possible to remotely display texts and values and enter values. The remote text display can be used for all easyRelay, easySafety, and easyControl units. It is made up of an MFD-80(-B) display/operating unit, an MFD(-AC)-CP4 power supply unit/communication module, and an
MFD-CP4-...CAB5 or EU4A-RJ45-CAB2 connecting cable.
Moreover, a high degree of protection of IP65 makes it suitable for use in harsh environments as well.
RS232 EASY-PC-CAB
MFD-CP4-500-CAB5
EU4A-RJ45-CAB1 RS232 EASY800-PC-CAB oder
EASY800-MO-CAB oder
MFD-CP4-800-CAB5
Packaging
Machine
SAFETY GATE 4
OPEN easy500/700 with XV Touch Panel as a HMI
Via the programming cable EASY-PC-CAB, control relays such as the easy500/700 can be connected to the XV Touch Panels.
The touch panel reads data from the control relay or writes setting values to it. easy500/700 assumes the control of the application. Display and operation are implemented through the comfortable visualisation options of the HMIs.
This was created using the GALILEO visualization software.
After selecting “easy 500/700” in Communications, the corresponding data types for the control relay are automatically created in GALILEO in the correct structure. This provides the visualization software with convenient access to the function block parameters for easy, allowing them to be linked to the visualization elements.
easy800 with XV Touch Panel as a HMI
In addition to the connection of easy800 and easySafety to an
XV Touch Panel via the programming cable EASY800-PC-CAB, a connection via EASY-MO-CAB is also possible. Baud transfer rates up to 57600 Baud can be implemented here. Both cables are about 2 m in length. The MFD-CP4-800-CAB facilitates an extended cable length up to 5 m between the devices.
As with easy500/700, the touch panel accesses the control relay data via the GALILEO visualization software. In Communications, select “easy 800/MFD” and enjoy easy access to the function block parameter for the control relay.
easyControl
SmartWire-DT
MFD-CP8/CP10 easy800
Communication and data exchange
In addition to the communication via easyNet, it is possible to exchange data with higher-level automation systems. Bus modules for connection to the AS-i, PROFI-
BUS-DP, CANopen and DeviceNet are available for this purpose. With the EASY209-SE, a connection possibility is available from
easyRelay and MFD-Titan to the Ethernet.
This facilitates remote access and programming via easySoft, as well as OPC functionality.
EATON CA08103003Z-EN-INT 71
CA08103003Z_MOEM2015-EN.book Seite 72 Donnerstag, 7. April 2016 12:02 12 ea y500, ea y700
System overview
System overview
1
1
3
3
2
2
5
6
7
8
Moeller® series
4
1 Control relay easy500
2 easy700 control relay
3 Remote text display: display/operating unit MFD-80(-B) + power supply unit/communication module with connection cable
MFD-(AC)-CP4-500
4 Ethernet gateway EASY209-SE
+ connection cable
MFD-CP4-500-CAB5
5 PROFIBUS-DP bus module-DP
EASY204-DP
6 ASi EASY205-ASI bus module
7 CANopen ® bus module EASY221-CO
8 DeviceNet bus module
EASY222-DN
9 EASY202-RE output expansion
10 EASY410... I/O expansion, digital
11 EASY6... I/O expansion, digital
12 EASY200-EASY Coupling module
POW
BUS
POWER
COM-ERR
ADR
ERR
MS
NS
9
10
11
12
11
10
Functions
• 16 counting relays (0 to 32000, up and down counting)
• 2 frequency counters (max. 1 kHz)
• 2 high-speed counters (max. 1 kHz)
• 4 hours-run counters (the operating hours value is super retentive, i.e. also retained with program change)
• 8 weekly timers (4 channels per time switch, 1 on/off point per channel)
• 8 year time switches
• 16 timing relays (0.01 s – 99 h 59 min, on-delayed and/or off-delayed (optional random switching), pulse shaping, flashing)
• 8 jump function blocks
• 3 master reset function blocks
• 16 analog value comparators
• 16 comparators
• 16 text displays (4 x 12 characters, editable via programming software)
• Value entry (counter values, setpoints, …)
• Value display (actual values, …)
• Date and time entry
• Date and time display
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 73 Donnerstag, 7. April 2016 12:02 12
Moeller® series ea y500, ea y700
Control Relays
Control Relays
Inputs
Digital Of which can be used as analog
Outputs
Relay 10 A
(UL)
Transistor
Additional features
Real time clock
Display & keypad
Supply voltage easy500
Stand alone
Customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
8 2 4 ✓ ✓ 24 V AC
8
8
8
8
8
8
8
8
2
2
2
2
-
-
-
2
4
4
4
4
4
4
4
4
-
-
-
-
-
-
-
-
-
✓
✓
✓
✓
✓
-
✓
✓
✓
-
✓
-
✓
-
✓
24 V AC
100 - 240 V AC
100 - 240 V AC
100 - 240 V AC
12 V DC
12 V DC
24 V DC
24 V DC
8
8
8
2
2
2 -
-
4 -
4
4
✓
✓
✓ -
-
✓
24 V DC
24 V DC
24 V DC easy700
Expandable: Digital inputs/outputs, bus systems AS-Interface, PROFIBUS-DP, CANopen®, DeviceNet
Customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
12 4 6 ✓ ✓ 24 V AC
12
12
12
12
-
4
-
4
6
6
6
6
-
-
-
-
✓
✓
✓
✓
-
✓
-
✓
24 V AC
100 - 240 V AC
100 - 240 V AC
12 V DC
12
12
12
12
12
4
4
4
4
4 -
-
6
6
6
-
8
-
-
8
✓
✓
✓
✓
✓ -
-
✓
-
✓
12 V DC
24 V DC
24 V DC
24 V DC
24 V DC
Programming and visualization software
Operating systems: Windows XP SP3, Windows Vista (32 bit), Windows 7 (32 bit + 64 bit), Windows 8 (32 bit + 64 bit)
For use with easy400/500/600/700
13 installation languages
For use with easy400/500/600/700/800/MFD-…-CP8/CP10
Function Description Length
Programming cable
For downloading the user program from PC to device
For use with easy500, easy700
SUB-D, 9 pole, serial
2 m
Part no.
Article no.
EASY719-AB-RC
274113
EASY719-AB-RCX
274114
EASY719-AC-RC
274115
EASY719-AC-RCX
274116
EASY719-DA-RC
274117
EASY719-DA-RCX
274118
EASY719-DC-RC
274119
EASY719-DC-RCX
274120
EASY721-DC-TC
274121
EASY721-DC-TCX
274122
EASY512-AB-RC
274101
EASY512-AB-RCX
274102
EASY512-AC-R
274103
EASY512-AC-RC
274104
EASY512-AC-RCX
274105
EASY512-DA-RC
274106
EASY512-DA-RCX
274107
EASY512-DC-R
274108
EASY512-DC-RC
274109
EASY512-DC-RCX
274110
EASY512-DC-TC
274111
EASY512-DC-TCX
274112
EASY-SOFT-BASIC
284545
EASY-SOFT-PRO
266040
EASY-PC-CAB
202409
For downloading the user program from PC to device
For use with easy500, easy700
USB 2 m EASY-USB-CAB
107926
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 74 Donnerstag, 7. April 2016 12:02 12 ea y800, MFD-Titan
System overview
System overview
1
1 5
3
2
5
6
7
8
9
10
Moeller® series
1 Control relay easy800
2 Control relay easy800 with
SmartWire-DT
3 Multi-function display MFD-Titan
4 easySafety safety relays
5 Remote text display: display/ operating unit MFD-80(-B)
+ power supply unit/communication module
MFD-(AC)-CP4
+ connection cable
MFD-CP4-800-CAB5
and EU4A-RJ45-CAB2
6 Ethernet gateway EASY209-SE
+ connection cable
MFD-CP4-800-CAB5 and EU4A-RJ45-CAB2
7 PROFIBUS-DP bus module
EASY204-DP
8 ASi EASY205-ASI bus module
9 CANopen ® bus module
EASY221-CO
10 DeviceNet bus module
EASY222-DN
11 EASY202-RE output expansion
12 I/O expansion, analog
EASY406-DC-ME /
EASY411-DC-ME
13 EASY410... I/O expansion, digital
14 EASY6... I/O expansion, digital
15 EASY200-EASY Coupling module
4
3
4
11
12 , 13
14
13
15
14
Functions easy800 / MFD-Titan (MFD-CP8/CP10)
• 32 counter relays (+/-2 31 , up, down counting)
• 4 frequency counters (easy800: max.
5 kHz, MFD-CP8/CP10: max. 3 kHz)
• 4 high-speed counters (easy800: max. 5 kHz, MFD-CP8/CP10: max. 3 kHz)
• 2 incremental counters
(easy800: max. 5 kHz, MFD-CP8/
CP10: max. 3 kHz)
• 4 hours-run counters (operating hours value is super retentive, i.e., also retained after program change)
• 32 weekly timers (4 channels per time switch, 1 on/off point per channel)
• 32 year time switches
• 1 set cycle time
• 32 timing relays (0.005 s – 2 32 min, on-delayed and/or off-delayed
(optional random switching), pulse shaping, flashing)
• 32 jump function blocks
• 32 conditional jumps
• 32 master resets
• 32 analog value comparators
• 32 comparators
(ADD, SUB, MUL, DIV)
• 32 PID controllers
• 32 PT1 signal smoothing filters
• 32 value scaling function blocks
• 32 numerical converters
• 2 pulse outputs (easy800)
• 2 pulse width modulations
• 32 value limitations
• 32 block comparisons
• 32 block transfers
• 32 Boolean sequences (AND, OR,
NOT)
• 32 comparators
• 32 data function blocks
• 32 data multiplexers
(easy800 and MFD-CP10..)
• 32 shift registers
• 32 table functions
• 32 get values from NET
• 32 put values to NET
• 32 Bit outputs via NET
• 32 Bit inputs via NET
• 32 serial protocols (easy800)
• 9 diagnostic alarms
• 1 synchronize clock via NET
• 32 text displays (4 x 16 characters)
(easy800)
• Value entry (counter values, setpoints, etc.) (easy800)
• Value display (actual values, …)
(easy800)
• Date and time input (easy800)
• Date and time display (easy800)
Visualization elements
MFD-Titan (MFD-CP8/CP10)
• Static text
• Message text
• Screen menu
• Running text
• Rolling text
• Date and time display
• Numerical value display (actual values, …)
• Timing relay value display
• Value entry (counter values, setpoints, etc.)
• Timing relay value entry
• Date and time entry
• Weekly timer entry
• Year time switch entry
• Latching pushbutton
• button field
• Bit display
• Bitmap
• Message bitmap
• Bargraph
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 75 Donnerstag, 7. April 2016 12:02 12
Moeller® series ea y800
Control Relays
Control Relays
Inputs
Digital be used as analog
Outputs
Relay 10 A
(UL)
Transistor Analog
Additional features
Real time clock
Display & keypad easy800
Expandable: Digital/analog inputs/outputs and AS-Interface, PROFIBUS-DP, CANopen®, DeviceNet bus systems
Bus system easyNet on board
Customized laser inscription or delivery with user program possible with EASY-COMBINATION-* product (article No. 2010781)
12 4 6 ✓ ✓
12
12
12
12
12
12
12
12
12
4
-
-
4
4
4
4
4
4
4
2
-
6
-
-
-
6
6
6
6
83
-
-
8
8
8
-
8
-
-
2
-
-
1
-
1
-
1
-
1
83
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓ -
-
-
✓
-
✓
-
✓
-
✓
Supply voltage
Inputs
Digital
Outputs
Transistor SmartWire-
Additional features
Real time clock
Display & keypad
Supply voltage be used as outputs easy800 with SmartWire-DT
Combines the functionality of an easy800 with direct connection to SmartWire-DT communication system
Up to 99 SmartWire-DT modules with a total of up to 166 digital inputs/outputs and/or up to 128 analog inputs/outputs can be connected via a
SmartWire-DT line
83 83 ✓ 24 V DC
Part no.
Article no.
24 V DC
24 V DC
24 V DC
24 V DC
EASY819-DC-RC
256269
EASY819-DC-RCX
256270
EASY820-DC-RC
256271
EASY820-DC-RCX
256272
24 V DC
24 V DC
EASY821-DC-TC
256273
EASY821-DC-TCX
256274
24 V DC
24 V DC
EASY822-DC-TC
256275
EASY822-DC-TCX
256276
100 - 240 V AC EASY819-AC-RC
256267
100 - 240 V AC EASY819-AC-RCX
256268
Part no.
Article no.
24 V DC
EASY802-DC-SWD
152901
EASY806-DC-SWD
152902
Programming and visualization software
Operating systems: Windows XP SP3, Windows Vista (32 bit), Windows 7 (32 bit + 64 bit), Windows 8 (32 bit + 64 bit)
For use with easy400/500/600/700/800/MFD-…-CP8/CP10
EASY-SOFT-PRO
266040
Programming cable
Function
For downloading the user program from PC to device
For use with easy800, MFD-…-CP8, MFD-…-CP10, ES4P
Description
SUB-D, 9 pole, serial
Length m
2
Part no.
Article no.
EASY800-PC-CAB
256277
For downloading the user program from PC to device
For use with easy800, MFD-…-CP8, MFD-…-CP10, EC4P, ES4P
USB 2 EASY800-USB-CAB
106408
For transferring the user program to the PLC or for diagnosing
SmartWire-DT networks
For use with EC4P, XC100, XC200, XC121, easy800-SWD, EU5C
For transferring the user program to the PLC or for diagnosing
SmartWire-DT networks
For use with EC4P, XC100 XC200, XC121, easy800-SWD, EU5C
SUB-D, 9 pole, serial
USB
2
2
EU4A-RJ45-CAB1
106726
EU4A-RJ45-USB-CAB1
115735
Bluetooth adapter
For secure radio connection between control relay and PC (programming and online communication)/Android smartphone and tablet (easyRemote display app, easyParameter app)
For use with easy81..., easy82..., MFD-CP8, MFD-CP10 ≧ V. 3.0, EC4P
EASY800-BLT-ADP
167651
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 76 Donnerstag, 7. April 2016 12:02 12
MFD-Titan
Multi-function display
Multi-function display
Description
Display/keypad
Monochrome display 132 × 64 pixels with switchable backlight, removable Titan front frame,
Custom laser inscriptions possible with MFD-COMBINATION (article no. 2010801) product
IP65
With keypad, with Eaton company logotype
NEMA type 3R; NEMA type 12; NEMA type 4x together with MFD-XM-80 protective diaphragm
With keypad, without Eaton company logotype
NEMA type 3R; NEMA type 12; NEMA type 4x together with MFD-XM-80 protective diaphragm
Without keypad, with Eaton company logotype
NEMA type 3R, NEMA type 12, NEMA type 4x
Without keypad, without Eaton company logotype
NEMA type 3R, NEMA type 12, NEMA type 4x
Supply voltage Description
Power supply unit/CPU modules
Can be combined with display/operating unit MFD-80-.. and I/O module,
Expandable: Digital/analog inputs/outputs and AS-Interface, PROFIBUS-DP, CANopen®, DeviceNet bus systems,
Bussystem easyNet optional on board, Program and screen memory,
Delivery with user program possible with MFD-COMBINATION product (Article no. 201801)
IP20, Spring-cage terminals
100 - 240 V AC Program and screen memory
100 - 240 V AC
24 V DC
24 V DC
24 V DC
Program and screen memory, with easyNet
Program and screen memory
Program and screen memory, with easyNet
Double program and screen memory like MFD-CP8…
24 V DC Double program and screen memory, as MFD-CP8…, with easyNet
Supply voltage Description
Power supply unit/communication module
Degree of protection IP20
Can be combined with display/operating unit MFD-80...as stand-alone text display
24 V DC
24 V DC
100 - 240 V AC
100 - 240 V AC
24 V DC
With connection cable (5 m, can be cut to length)
With connection cable (5 m, can be cut to length)
With connection cable (5 m, can be cut to length)
With connection cable (5 m, can be cut to length)
Without connection cable
100 - 240 V AC Without connection cable
For use with easy500 easy700 easy800
ES4P easy500 easy700 easy800
ES4P
MFD-80…
MFD-80…
Moeller® series
Part no.
Article no.
MFD-80-B
265251
MFD-80-B-X
284905
MFD-80
265250
MFD-80-X
284904
Part no.
Article no.
MFD-AC-CP8-ME
274091
MFD-AC-CP8-NT
274092
MFD-CP8-ME
267164
MFD-CP8-NT
265253
MFD-CP10-ME
133801
MFD-CP10-NT
133800
Part no.
Article no.
MFD-CP4-500
274094
MFD-CP4-800
274095
MFD-AC-CP4-500
286823
MFD-AC-CP4-800
286824
MFD-CP4
280888
MFD-AC-CP4
286822
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 76 Donnerstag, 7. April 2016 12:02 12
MFD-Titan
Multi-function display
Multi-function display
Description
Display/keypad
Monochrome display 132 × 64 pixels with switchable backlight, removable Titan front frame,
Custom laser inscriptions possible with MFD-COMBINATION (article no. 2010801) product
IP65
With keypad, with Eaton company logotype
NEMA type 3R; NEMA type 12; NEMA type 4x together with MFD-XM-80 protective diaphragm
With keypad, without Eaton company logotype
NEMA type 3R; NEMA type 12; NEMA type 4x together with MFD-XM-80 protective diaphragm
Without keypad, with Eaton company logotype
NEMA type 3R, NEMA type 12, NEMA type 4x
Without keypad, without Eaton company logotype
NEMA type 3R, NEMA type 12, NEMA type 4x
Supply voltage Description
Power supply unit/CPU modules
Can be combined with display/operating unit MFD-80-.. and I/O module,
Expandable: Digital/analog inputs/outputs and AS-Interface, PROFIBUS-DP, CANopen®, DeviceNet bus systems,
Bussystem easyNet optional on board, Program and screen memory,
Delivery with user program possible with MFD-COMBINATION product (Article no. 201801)
IP20, Spring-cage terminals
100 - 240 V AC Program and screen memory
100 - 240 V AC
24 V DC
24 V DC
24 V DC
Program and screen memory, with easyNet
Program and screen memory
Program and screen memory, with easyNet
Double program and screen memory like MFD-CP8…
24 V DC Double program and screen memory, as MFD-CP8…, with easyNet
Supply voltage Description
Power supply unit/communication module
Degree of protection IP20
Can be combined with display/operating unit MFD-80...as stand-alone text display
24 V DC
24 V DC
100 - 240 V AC
100 - 240 V AC
24 V DC
With connection cable (5 m, can be cut to length)
With connection cable (5 m, can be cut to length)
With connection cable (5 m, can be cut to length)
With connection cable (5 m, can be cut to length)
Without connection cable
100 - 240 V AC Without connection cable
For use with easy500 easy700 easy800
ES4P easy500 easy700 easy800
ES4P
MFD-80…
MFD-80…
Moeller® series
Part no.
Article no.
MFD-80-B
265251
MFD-80-B-X
284905
MFD-80
265250
MFD-80-X
284904
Part no.
Article no.
MFD-AC-CP8-ME
274091
MFD-AC-CP8-NT
274092
MFD-CP8-ME
267164
MFD-CP8-NT
265253
MFD-CP10-ME
133801
MFD-CP10-NT
133800
Part no.
Article no.
MFD-CP4-500
274094
MFD-CP4-800
274095
MFD-AC-CP4-500
286823
MFD-AC-CP4-800
286824
MFD-CP4
280888
MFD-AC-CP4
286822
CA08103003Z_MOEM2015-EN.book Seite 77 Donnerstag, 7. April 2016 12:02 12
Moeller® series
MFD-Titan
Multi-function display
Supply voltage For use with
I/O modules
24 V DC
24 V DC
24 V DC
24 V DC
MFD-CP8..
MFD-CP10..
100 - 240 V AC MFD-AC-CP8…
I/O modules with temperature measuring
24 V DC
24 V DC
MFD-CP8… from device version 08
MFD-CP10..
24 V DC
24 V DC
24 V DC
24 V DC
6
6
6
6
6
6
12
12
12
12
12
Inputs
Digital Of which can be used as analog
Pt100
-
4
4
4
4
-
-
-
-
-
2
2
2
2
2
2 -
2
2
2
2
-
-
-
-
-
-
-
-
-
4
4
4
Outputs
Relay
10 A (UL)
Transistor Analog
Temperature range
Part no.
Article no.
-
-
-
4
4
4
4
4
4
4
4
-
-
-
-
-
-
1
1
1
1
1
-
-
-
-
-
MFD-R16
265254
MFD-T16
265255
MFD-RA17
265364
MFD-TA17
265256
MFD-AC-R16
274093
-40…+90 °C
0…+250 °C
0…+400 °C
-200…+200 °C
0…+850 °C
-40…+90 °C
0…+250 °C
MFD-TP12-PT-A
106042
MFD-TAP13-PT-A
106045
MFD-TP12-PT-B
106043
MFD-TAP13-PT-B
106046
MFD-TP12-NI-A
106044
MFD-TAP13-NI-A
106047
76 EATON CORPORATION CA08103003Z-EN Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 78 Donnerstag, 7. April 2016 12:02 12
Accessories
Expansions
Expansions
Inputs
Digital
I/O expansions, digital
Can be used through easyLink
-
12
12
12
6
-
6
2
Outputs
Relay 10 A (UL) Transistor
-
-
-
8
Supply voltage
100 - 240 V AC
24 V DC
24 V DC
24 V DC
Moeller® series
Part no.
Article no.
EASY618-AC-RE
EASY620-DC-TE
EASY618-DC-RE
EASY202-RE 1)
212314
212313
232112
232186
6
6 -
4 -
4
Fir remote connection of a digital I/O extension up to 30 m.
24 V DC
24 V DC
EASY410-DC-RE
EASY410-DC-TE
114293
114294
EASY200-EASY 212315
Inputs
Digital Analog Of which usable as digital inputs
I/O expansions, analog
Can be used through easyLink
1
1
2 2)
6 3)
2
2 -
-
Outputs
Relay
10 A (UL)
Transistor Analog
Supply voltage
2
2
1
2
24 V DC
24 V DC
Notes 1)
2)
3)
Not for use in combination with EASY719-DA-… basic devices
Cannot be used on the EASY200-EASY coupling module
2 x 0 - 10 V or 2 x 0 - 20 mA or 2 x RTD (2/3-wire connection);
Voltage inputs (0 -10 V), optionally usable as digital inputs
2 x 0 - 10 V and 2 x 0 - 20 mA and 2 x RTD (2/3-wire connection);
Voltage inputs (0 -10 V), optionally usable as digital inputs
Part no.
Article no.
EASY406-DC-ME
EASY411-DC-ME
114295
116567
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 78 Donnerstag, 7. April 2016 12:02 12
Accessories
Expansions
Expansions
Inputs
Digital
I/O expansions, digital
Can be used through easyLink
-
12
12
12
6
-
6
2
Outputs
Relay 10 A (UL) Transistor
-
-
-
8
Supply voltage
100 - 240 V AC
24 V DC
24 V DC
24 V DC
Moeller® series
Part no.
Article no.
EASY618-AC-RE
EASY620-DC-TE
EASY618-DC-RE
EASY202-RE 1)
212314
212313
232112
232186
6
6 -
4 -
4
Fir remote connection of a digital I/O extension up to 30 m.
24 V DC
24 V DC
EASY410-DC-RE
EASY410-DC-TE
114293
114294
EASY200-EASY 212315
CA08103003Z_MOEM2015-EN.book Seite 79 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Inputs
Bus modules
Can be used through easyLink
AS-Interface
PROFIBUS-DP
Slave
4 inputs
4 outputs
4 parameter bits
Addresses available: 0 - 31
Slave
Addresses available: 1 - 126
CANopen® Addresses available: 1 - 127
DeviceNet Addresses available: 0 - 63
-
Supply voltage
24 V DC
24 V DC
24 V DC
Ethernet gateway
Serial interface easyRelay or MFD-...CP8/CP10... to Ethernet for connection to easyOPC server, easySoft, or easyCom
24 V DC
Inputs
Digital Analog Of which usable as digital inputs
I/O expansions, analog
Can be used through easyLink
1
1
2 2)
6 3)
2
2 -
-
Outputs
Relay
10 A (UL)
Transistor Analog
Supply voltage
2
2
1
2
24 V DC
24 V DC
Notes 1)
2)
3)
Not for use in combination with EASY719-DA-… basic devices
Cannot be used on the EASY200-EASY coupling module
2 x 0 - 10 V or 2 x 0 - 20 mA or 2 x RTD (2/3-wire connection);
Voltage inputs (0 -10 V), optionally usable as digital inputs
2 x 0 - 10 V and 2 x 0 - 20 mA and 2 x RTD (2/3-wire connection);
Voltage inputs (0 -10 V), optionally usable as digital inputs
Part no.
Article no.
EASY406-DC-ME
EASY411-DC-ME
114295
116567
Part no.
Article no.
Accessories
Expansions
EASY205-ASI
221598
EASY204-DP
212316
EASY221-CO
233539
EASY222-DN
233540
EASY209-SE
101520
78 EATON CORPORATION CA08103003Z-EN Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
easyPower, ELC-PS and PSG power supply units
Whether at the machine or plant, in the control cabinet or service distribution board – the easyPower, ELC-PS and PSG 24 V DC power supply units provide the right solution and design for any requirement. These rail-mounted power supply units provide a reliable 1-phase and 3-phase supply for efficient operation. In addition to the wide range inputs and approvals for worldwide use, these devices stand out on account of their optimum efficiency and large temperature range. The short-circuit proof design and overload withstand capability ensure a safe power supply. The compact housing saves space and costs. The adjustable output voltage range of the PSG power supply units ensures optimum adaptability. With an output current of 1 A to 40 A, the power supply units are designed to supply machines and plants with low power requirements as well as large current loads.
80 www.eaton.eu/psg
EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 81 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Power supplies
Input voltage range
Single-phase power supplies
Nominal input voltage: 100 - 240 V AC
85 - 264 V AC
85 - 264 V AC
Setting range for the output voltage: 22-28 V DC
85 - 264 V AC
(120 - 375 V DC)
Rated output voltage Rated output power
W
Rated output current
A
Part no.
Article no.
24 V DC (± 3%)
12 V DC (± 4%)
24 V DC (± 3%)
24 V DC (± 3%)
24 V DC (± 3%)
24 V DC (± 2%)
-
-
-
24
48
60
60
120
240
480 easyPower, ELC-PS, PSG
Power supplies
1
2
0.35
0.02
1.25
2.5
5
10
2.5
2.5
20
EASY200-POW
229424
EASY400-POW
212319
EASY500-POW
110941
ELC-PS01
135239
ELC-PS02
135240
PSG60N24RP
172890
PSG60E24RM
172891
PSG120E24RM
172892
PSG240E24RM
172893
PSG480E24RM
172894
3-phase power supplies
Nominal input voltage: 3 x 400 - 500 V AC
Setting range for the output voltage: 24 - 28 V DC
320 - 600 V AC
(450 - 800 V DC)
24 V DC (± 2%) 60
120
240
480
960
10
20
2.5
5
40
PSG60F24RM
172882
PSG120F24RM
172883
PSG240F24RM
172884
PSG480F24RM
172885
PSG960F24RM
172886
Power supplies PSG, Redundancy module
For decoupling power supplies of the same type that are connected in parallel on the output side for redundancy purposes
Input voltage range 22 - 60 V DC
Rated output current 20 A
Rated output current 40 A
Power supplies PSG, Buffer module
For maintaining operation during brief power failures; the backup time can be multiplied by connecting in parallel
Input voltage range 22,8 - 28,8 V DC
Rated output current 20 A
Backup time depends on load current 250 ms (20 A) to max. 5 s (1 A)
Part no.
Article no.
PSG480R24RM
172888
PSG960R24RM
172889
PSG480B24RM
172887
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Titel
Untertitel
82
Functional safety for persons, machine and environment
A machine poses dangers to persons, machinery and the environment over the entire life cycle of a machine – from manufacture to dismantling. It is therefore vital that these dangers are identified already during the design phase of the machine and reduced with suitable measures.
The Machinery Directive 2006/42/EC requires that machines do not pose any dangers. However, as there is no such thing as 100 % safety in engineering, the objective is to reduce these sources of danger to a tolerable level of residual risk. The overall safety of a machine defines the state which is deemed to be free of unwarranted risks for persons or which is deemed to be danger free. The functional safety describes the proportion of the overall safety of a system that is dependent on the correct function of the safetyrelated systems and external devices in order to reduce the risks.
www.eaton.eu/fusi
EATON CA08103003Z-EN-INT
Functional safety for persons, machine and environment
Risk reduction through the use of safety-related parts of control systems
The elements of machine controls which assume safety-related tasks are designated by international standards as “safety-related parts of control systems” (SRP/CS). Safety-related parts of control systems each incorporate the entire functional chain of a safety function, consisting of the input level (sensor), the logic
(safe signal processing) and the output level (actuator).
The general objective is to design these parts so that the safety of the control functions as well as the reaction of the control system in the event of a malfunction complies with the degree of risk reduction determined in the risk analysis. The higher the level of risk reduction to be provided by the safety-related parts of a control system, the higher the safety level or the technical safety performance level demanded of the control section.
Fast and secure detection Safe monitoring and processing Reliable shutdown
Input Logic Output
Safety manual for machines and plants in accordance with EN ISO 13849-1 and IEC 62061
Eaton has written the Safety Manual for machine and plant builders, trainers and trainees as well as interested customers having to deal with the issue of
“machine and plant safety”.
This provides an easy entry level into the extensive range of material on safety technology. The Eaton Safety Manual contains an overview of the most important factors involved in directives, standards and regulations that have to be taken into consideration when using safety equipment on machines. The safety-related contents in this manual have been checked by TÜV Rheinland Industrie Service
GmbH.
The manual uses example circuits to show how the functional safety can be implemented with electrical, electronic and programmable components and systems in safety applications.
t009d.book Seite 25 Freitag, 17. September 2010 9:49 09
+24 V
-F2 -F1
-K1
+24V 0V
DC 24 V
0V
-S1
Start
IS1 IS2
Input 14 x DC
-S2
Stopp
Kat
Kat
PL
B 1 2 3 a b c d
4 e
PL
IS4
SIL
IS5 IS6 IS7 IS8 IS9
-Q2
3
IS10 e
IS3
SIL 1 2 3
IS11 IS12 IS13 IS14
NET
L1
L2
L3
PL
-Q4 a b c d e
SIL 1 2 3
-Q1
-Q2
B 1 2 3 4
I > I > I >
L1
L2
L3
PE
Funktionsweise
P1
P2
P3
Funktionsweise
ESC
P4
OK
Der NOT-HALT-Taster S4 muss sich in Freigabe-Stellung (Öffnerkontakte geschlossen) befinden, damit die Freigabe über den
-Q3
T2
RESET-Taster S3 erteilt werden kann. Mit dem Betätigen des
T3
START-Tasters S1 wird die Gefahr bringende Bewegung in Gang
Programm realisiert. Die beiden Schütze fallen ab, ein erneutes
T4
Starten ist durch Betätigen der START-Taste möglich. Wird während
-R1
PE
Schütze fallen ab. Ein erneutes Starten ist erst nach Rücksetzen des
RESET-Taste möglich.
RESET-Taste möglich.
Mit der Verwendung des Ausgangs QS4 kann der Antrieb aktiv gebremst werden. Diese Option wird jedoch nicht in die Sicherheitsbetrachtung einbezogen, da der Frequenzumrichter den sicheren
Bremsvorgang nicht unterstützt.
The Safety Manual also provides a description of the functions as well as a clear presentation of a possible evaluation of each circuit example.
The calculated characteristic values apply to the assumptions made in the safety applications and the safety-related switchgear in use.
Condition Bedingung
Bedingung
Structure
Struktur d
EN ISO 13849-1:2008
Kat. 4
Kat. 4 100 years
Condition
Struktur
Structure d
IEC 62061
M
3 h
PE
TS D, symmetrisch
1,74 x 10 -8
Simply register online at www.eaton.eu/shb and work online with the safety manual or download the safety manual free-of-charge.
MTTF d
B10 d
B10 d n op n op
CCF 1800 80
DEL ALT
PFH d
B10
B10 l d
/ l l d
/ l
C
For safety-relevant characteristic values for our products, please visit our website www.eaton.eu/fusi
CCF DC avg
DC avg
PL
PL
T10 d
T10 d
80 99 %
99 % e e >20 years
>20 Jahre
C
ß
DC
SIL
ß
DC
SIL
0,05 S4: 99 %, K1: 99 %, Q1 - Q2: 99 %
3
EATON CA08103003Z-EN-INT 83
Sicherheitsgerichtete Schaltgeräte
Sicherheitsgerichtete Schaltgeräte
Fuß- und Grobhandtaster FAK
Fuß- und Grobhandtaster FAK
Sicherheitsnormen
Norm
EN ISO 13849-1/2
EN ISO 13849-1/2
IEC 62061
IEC 62061
IEC 60947-4-1
IEC 60947-4-1
EN ISO 13850
EN ISO 13850
Sicherheitsgerichtetes Steuerrelais
E
Safety
ES4P-221-DMXD1
E Safety
ES4P-221-DMXD1
Leistungschütze DILM12
Leistungschütze DILM12
Inhalt a Seite
Inhalt
Sicherheit von Maschinen - Sicherheitsbezogene Teile von Steuerungen -
Teil 1: Allgemeine Gestaltungsleitsätze a
96
Teil 1: Allgemeine Gestaltungsleitsätze
Teil 2: Validierung tronischer und programmierbarer elektronischer Steuerungssysteme
97 Sicherheit von Maschinen - Funktionale Sicherheit sicherheitsbezogener elektrischer, elektronischer und programmierbarer elektronischer Steuerungssysteme
Niederspannungsschaltgeräte - Teil 4-1: Schütze und Motorstarter; Elektromechanische
Schütze und Motorstarter
–
Seite
96
97
–
101
Sicherheit von Maschinen - Not-Halt - Gestaltungsleitsätze 101
10/10 PU05907001Z-DE
10/10 PU05907001Z-DE 25
25
Safe monitoring and processing
Machines and plants contain potentially dangerous motion sequences that require a technical solution to make them safe. Safety devices such as emergency-stop pushbuttons, guard doors, light curtains and operating elements for safe setting must be controlled and monitored, and the installation may have to be switched to a safe state. For these tasks,
Eaton is offering two safety logic series, the ESR5 electronic safety relay and the easySafety control relay.
Whether on a simple or complex machine, the required protection of personnel and process can be ensured using these Eaton safety products that have been approved by TÜV Rheinland:
• Performance Level PL e to EN ISO 13849-1
• Safety Integrity Level SILCL 3 according to IEC 62061
www.eaton.eu/esr5
www.eaton.eu/es4p
84 EATON CA08103003Z-EN-INT
Designing logic processes safely
ESR5 series safety relays monitor the signals of safety devices reliably and switch off safely and rapidly in the event of an emergency. The internal logic of the safety relays monitors the wired safety circuits and activates the enable paths when no faults are present.
The easySafety control relay monitors all typically used safety devices and also performs the control tasks required for the machine. Armed with a host of conventional safety relays in the form of safety function blocks, easySafety not only integrates safety but also standard functions in a single all-inone device.
Economical monitoring with the ESR5 safety relay
• Many safety switch contacts with up to 5 enable and
2 signal current paths
• Immediate (stop category 0) or delayed (stop category 1) stopping
• Duplication using contact expansion modules
• Optimum space saving thanks to slim 22.5 mm mounting width
• Pluggable screw terminals for fast and fault-free exchange
• Multi-voltage versions 24 – 230 V AC/DC for flexible application range
• World market devices with UL, cUL and TÜV Rheinland certification
All in one – safety and control relay rolled into one
• Safety circuit diagram and standard circuit diagram integrated in the same device
• TÜV-approved safety function blocks
• 14 safety inputs
• 4 safety transistor outputs and 1 redundant relay output or 4 safety relay outputs
• 4 test signals
• Local expandable via integrated easyLink interface
• Remotely expandable via integrated easyNet interface
• With or without display
• Additional stand-alone display can be connected via integrated RS232 interface
EATON CA08103003Z-EN-INT 85
CA08103003Z_MOEM2015-EN.book Seite 86 Donnerstag, 7. April 2016 12:02 12
Functional safety
Monitoring and Processing
Functional safetyMonitoring and Processing
Part no.
Article no.
ESR5
Overall width: 22.5 mm or 45 mm
✓ ✓
✓
✓
✓
✓
✓
✓ -
-
-
-
-
-
-
-
✓
✓
✓
✓
✓
✓
-
-
✓
✓
✓
✓
✓
✓
✓
✓
3
3
2
2
-
-
-
-
1
1
1
1
-
-
-
PL e / Kat. 4
PL e / Kat. 4
PL e / Kat. 4
PL e / Kat. 4
SILCL 3
SILCL 3
SILCL 3
SILCL 3
ESR5-NO-21-24VAC-DC
118700
ESR5-NO-31-24VAC-DC
118702
ESR5-NO-31-230VAC
119380
ESR5-NO-31-AC-DC
118704
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
-
-
-
-
-
✓
✓
✓
-
✓
-
-
✓
✓
✓
✓
✓
✓
-
-
2
3
4
3
2
2
-
-
-
-
1
1
-
1
-
PL c / Kat. 1
PL c / Kat. 1
PL e / Kat. 4
PL e / Kat. 4
SILCL 1
SILCL 1
SILCL 3
SILCL 3
ESR5-NO-41-24VAC-DC
118701
ESR5-NOS-31-230VAC
153152
ESR5-NV3-30
118705
ESR5-NV3-300
171858
✓ ✓ ✓ 2 1 PL e / Kat. 4 SILCL 3 ESR5-NZ-21-24VAC-DC
118703
-
-
-
-
✓
✓ -
-
-
✓
✓ -
-
-
5 -
4
1
1 -
PL e / Kat. 4
PL d / Kat. 3
SILCL 3
SILCL 3
ESR5-NE-51-24VAC-DC
118707
ESR5-VE3-42
118706
With light curtain functionality
✓ ✓ ✓ ✓ 3 1 PL e / Kat. 4 SILCL 3 ESR5-BWS-31-24VAC-DC
180413
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 87 Donnerstag, 7. April 2016 12:02 12
Moeller® series
ES4P
– Stopping in the event of an emergency
– Protective door
– ESPE with muting function
– Two-hand control
– Highest speed monitoring
– Zero speed monitoring
– Safety timing relay
– Mode selection
– Enabling switch
– Feedback circuit
– Mounting width: 107.5 mm
– 14 Inputs (safety) 24 V DC
– Rated operational voltage: 24 V DC
Safety related characteristics
– Performance level according to EN ISO 13849-1 PL e / Cat. 4
– Safety integrity level claim limit in accordance with 62061 SILCL 3
Functional safety
Monitoring and Processing
Transistor outputs
Relay outputs Display & keypad
Part no.
Article no.
-
4
-
4
1 (redundant) ✓
4 ✓
1 (redundant)
4
-
-
ES4P-221-DMXD1
111017
ES4P-221-DRXD1
111019
ES4P-221-DMXX1
111016
ES4P-221-DRXX1
111018
Description
ES4P add-on functions
Programming Software easySoft-Safety
Menu selection in German, English, French, and Italian
Operating systems: Windows XP SP3, Windows 7 (32 bit + 64 bit), Windows 8 (32 bit + 64 bit)
Memory card
256-kB module
Part no.
Article no.
ESP-SOFT
111460
ES4A-MEM-CARD1
111461
Function
Programming cable
For downloading the user program from PC to device
For use with easy800, MFD-…-CP8, MFD-…-CP10, ES4P
For downloading the user program from PC to device
For use with easy800, MFD-…-CP8, MFD-…-CP10, EC4P, ES4P
Description Length m
SUB-D, 9 pole, serial 2
USB 2
Part no.
Article no.
EASY800-PC-CAB
256277
EASY800-USB-CAB
106408
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
GALILEO:
Visualization at a whole new Level
Eaton's GALILEO is a powerful and comprehensive visualization program that can be used to configure any XV or XP touch panel.
GALILEO is an intuitive and powerful engineering environment that not only takes little time to master, but that also meets virtually every requirement involved in on-site machine operation. The visualization software, developed by Eaton, is designed to meet the needs of any industry while providing comprehensive configuration options for all XV devices and PC runtime solutions. As part of this approach, GALILEO puts its full functionality at the disposal of design engineers at all times, avoiding nested variable and screen limitations.
A single visualization program for all XV/XP families
88 www.eaton.eu/galileo
EATON CA08103003Z-EN-INT
GALILEO
Visualization Software
Easy and intuitive to use and test
• An intuitive and powerful design environment
• There are no limits on the number of tags and images that can be used by functions
• Project simulations on the development computer reduce design and
commissioning times
• Thanks to the full forward compatibility of all your projects, you can rest assured knowing your investment will yield dividends for a long time
Custom-tailored for international mechanical engineering
• Pre-defined, language-specific keypad configurations
• Change languages online
• Change units in runtime (e.g., °C to °F or cm to inches)
• Unicode support (also Asian character sets)
• The ability to import text from and export text to Excel makes it possible to quickly create error-free translations
• All devices are UL approved
Varied communication possibilities
• Over 100 protocols for almost all current PLCs makes it possible to use
GALILEO in conjunction with PLC systems from other makers as well
• Communication to CODESYS-V2 and CODESYS-V3
• Easily import PLC variables in XML format
• Secure, reliable, and easy connection to your control system level and to
Office
• Up to eight simultaneous communication processes
• Remote client/server and OPC client
• Remote control via smartphone
Further Galileo highlights
• Powerful and easy-to-use design features such as styles, color gradients, semi-transparency, and full transparency
• Gesture-based controls (swipe, scroll, zoom)
• The ability to reuse object groups
• The ability to scroll through subscreens (that cannot be displayed in their entirety) by using a viewing window
• Supports switching between 16:9 and 4:3 panel aspect ratios
• Single-line and multi-line alarm messages with integrated variables
• Variables, objects, bitmaps, and styles can be copied between projects
Which visualization software for which device?
Galileo 8
Galileo 10
Galileo 10 Webserver
•
XV‐102‐A… XV‐102‐H… XV‐102‐B/‐D/‐E‐… XV‐112…
•
•
1) Except XV-102 with monochrome 3.5" displays 2)
•
• 1 •
•
Except XV(S) devices with 256 colors
Description
•
•
XV‐152…
•
•
XV‐3x3‐…
•
XV(S)‐4…
• 2 •
•
XC‐152‐…
•
•
•
XP‐503‐…‐1B
Part no.
Article no.
GALILEO
License certificate for visualization software GALILEO
MS Windows TM -based intelligent and intuitive visualization tool, single-workstation license
License certificate for visualization software GALILEO
MS Windows TM -based intelligent and intuitive visualization tool, multi-workstation license
GALILEOOpen license for PC
For continuous, unrestricted operation of the GALILEO runtime systems on a standard PC.
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
SW-GALILEO-S
171500
SW-GALILEO
140379
LIC-GALILEO-OPEN-PC
140385
89
90
XSOFT-CODESYS: PLC programming to international standards
Software tools make both engineering and commissioning easier:
• XN300 Assist
• I/O-Assist
• SWD-Assist
Download free of charge at www.eaton.eu/software
CODESYS is a programming system that is based on 3S' CODESYS standard. And with its sophisticated technical features, ease of use, and popularity as a programming system for automation components from a wide variety of manufacturers, it is no surprise that it has become the system of choice for many a successful company. Eaton offers both
CODESYS Version 2 and Version 3, and most XV/XC controllers can be programmed with either version.
CODESYS is the ideal programming tool for applications in which a powerful PLC or HMI PLC with various field bus connections is required.
The reason why is its integrated field bus configurators for PROFIBUS,
CAN, SmartWire-DT, Modbus TCP/RTU (in Version 3), and EtherNet/
IP (in Version 3), which make it possible to quickly, intuitively, and easily connect devices to the field bus of your choice. In short, the software is the ideal programming tool for all machine and process-relevant applications in mechanical and plant engineering environments.
www.eaton.eu/codesys
EATON CA08103003Z-EN-INT
•
•
•
•
3
3
3
3
• • • •
XV-102-B/-D/-E-…
XV-112…
• • • •
XV-152…
XV-3x3-…
• • • •
XV(S)-4…
XC-152-…
• • • •
XC-CPU202-…
XC-CPU201-…-XV
•
XC-CPU201-/101-…
•
XC-CPU121
•
EC4P-…
• XN-PLC-CANOPEN •
•
•
• •
•
•
•
XN-312-GW-CAN
XNE-GWBR-…
• • XN-GWBR-…
3) for devices with SmartWire-DT interface
Maximum flexibility
CODESYS is the programming tool for all Eaton XV/XC controllers. It enables users to program systems as per IEC-1131-3 with the following programming languages: instruction list (IL), ladder diagram (LD), function block diagram
(FBD), sequential function chart (SFC), structured text (ST), continuous function chart (CFC).
Eaton offers targets for the XV100, XV400, XVS400, XC-152, and XC-CPU202 automation systems both for CODESYS V3 and CODESYS V2, meaning that the same hardware can be used in new (configured with CODESYS 3) and existing (programmed with CODESYS 2) machine generations!
Multitasking
The structuring of the application into several user-defined runtime programs
(multitasking) optimizes your PLC's resources and simplifies the implementation of time-critical requirements. Give high-speed processes priority and slower processes as much processing time as is necessary.
Web visualization
XSOFT CODESYS can generate an XML description based on visualization information. In CODESYS V2, this description will be stored on the controller together with a Java applet. In CODESYS V3, HTML5-based pages
( CODESYS V3) will be generated instead. These pages can then be displayed on a browser via TCP/IP.
Application libraries
Eaton Automation offers several ready-to-use libraries for programming PLCs with XSOFT-CODESYS for a wide range of applications:
• Control technology toolbox
• Motion control toolbox
• FTP server
• FTP client
• UDP and TCP/IP
• Modbus RTU/TCP master/slave
• OS functions
• File handling
XSOFT CODESYS Version 3 features:
• a programming tool that can be expanded using plugins to handle
customer-specific adaptations
• expanded language options (object-oriented programming)
• Know-how protection for targets and the programming tool
• multiple PLC programs in one project
• New and improved TargetVisu functions
• improved IT safety functions
• Websites based on HTML5
• Field bus configurations: Modbus TCP/RTU, EtherNet/IP
• SAE J1939 protocol
Description
XSOFT-CODESYS-2
Programming to IEC 61131-3, supports XV100, XV300, XV(S)400, XC100, XC200, EC4P, XN-PLC
Single user license
Multi-user license
XSOFT-CODESYS-3
Programming to IEC 61131-3, supports XV100, XV300, XV(S)400, XC-152, XC-202
Single user license
Multi-user license
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Part no.
Article no
SW-XSOFT-CODESYS-2-S
142582
SW-XSOFT-CODESYS-2-M
142583
SW-XSOFT-CODESYS-3-S
171886
SW-XSOFT-CODESYS-3-M
171887
91
Control circuit devices RMQ Titan, 22 mm range
Push-button Indicator lights flush, titanium ring
IP67, IP69K – spring-return / stay-put flush
IP66 spring-return / stay-put extended, titanium ring
IP67, IP69K – spring-return / stay-put
IP67, IP69K – spring-return / stay-put
IP66 extended / flush extended
Illuminated push-button actuators flush, titanium ring
IP67, IP69K spring-return / stay-put extended, titanium ring
IP67, IP69K spring-return / stay-put
Illuminated thumb-grip selector switch
– opposing buttons not mechanically interlocked
– opposing buttons mechanically interlocked
2 and 4 positions horizontal and vertical
RMQ compact solution
FAK switch
Illuminated push-button actuators
IP67, IP67K tamper proof stay-put
92 EATON CA08103003Z-EN-INT
IP66, IP69K pull or turn to reset illuminated / not-illuminated
IP66, IP69K pull or turn to reset, mechanical switch position indication
Front and base fixing, screw / spring-loaded terminals,
Front and base fixing with and without LED
Signal towers SL
Card with continuous / flashing light
Single-channel, dualchannel, dual-channel with signaling contact for front and base
Control circuit devices RMQ 16
Illuminated actuators Selector switch actuators
IP65 flush / extended
18 x 18 mm and
25 x 25 mm
Illuminated push-button actuators
IP65 spring-return / stay-put
18 x 18 mm and
25 x 25 mm
IP65 spring-return / stay-put
2 / 3 positions
18 x 18 mm and
25 x 25 mm
Key-operated actuators
IP65 spring-return / stay-put
2 / 3 positions
18 x 18 mm and
25 x 25 mm
Push-button actuators
IP65 spring-return / stay-put
18 x 18 mm and
25 x 25 mm
See Online Catalog
EMERGENCY-STOP/OFF buttons
IP65, 25 x 25 mm illuminated / not-illuminated
Emergency-Stop labels in four languages / blank
Contact blocks
EATON CA08103003Z-EN-INT
N/O / N/C terminal connection
Screw connection with screw connection adapter for N/O, N/C, and lamp sockets
93
Mechanical position detection
Safe position detection
Optical product recognition
Comet series photoelectric sensors / emitters
Spring-powered or magnet-powered interlock
94
Analog electronic position switch
EATON CA08103003Z-EN-INT
Inductive metal detection
Intelligent sensor adaption
Detection of times, fill levels and currents
Checking capacitive fill levels
Electronic measuring and monitoring relays EMR4
Premium Plus series
Monitoring pressure
See Online Catalog
Pressure switch
Monitoring of liquid and gaseous media
See Online Catalog
EATON CA08103003Z-EN-INT 95
Catalog download: www.eaton.eu/catalog
96
In great shape: The ergonomic control circuit devices RMQ-Titan®
® www.eaton.en/rmq
Modern styling has been combined with an optimum range of functions.
The perfect outfit for use at machines and on panels. The ergonomically shaped button elements are matched to the shape of a fingertip for even more comfortable operation.
RMQ-Titan pilot devices can be flexibly used in a wide range of applications thanks to their IP67/IP69K degree of protection. The RMQ compact solution series is not only characterized by compact dimensions, but also by an unbeatably high degree of protection (IP65) at the back of its devices.
The Emergency-STOP buttons 1) for the worldwide usable control circuit device product range RMQ-Titan are available as palm switches/ mushroom actuators with a diameter of 38, 45 or 60 mm.
RMQ-Titan pilot devices have been granted numerous national approvals and ship classifications, meaning they are ready for use anywhere in the world.
Control circuit devices RMQ-Titan are ingeniously simple to connect with SmartWire-DT.
1) The EMERGENCY-STOP devices from Eaton can also be used as EMERGENCY-OFF devices.
EATON CA08103003Z-EN-INT
Direct installation in machine rooms
Safe shutdown with RMQ-Titan
The EMERGENCY-STOP or EMERGENCY-OFF buttons are available with and without a key, turn-release, non-illuminated, illuminated with standard LED or with mechanical switch position display (green/red) in the centre of the actuation element. Self-monitoring contact blocks guarantee comprehensive operational safety: even with incorrect installation or after unduly powerful actuation.
The new devices in the RMQ compact solution series come with their cables, plug connector, and housing already integrated and installed in a non-detachable manner. This turns them into an all-in-one solution that provides full protection against dust, fine foreign particles, and liquids thanks to IP67 and IP69K degrees of protection in the front and IP65 in the back. In other words, these devices can be used right where the corresponding machines are, without the need for any extra enclosures.
Flush RMQ pushbuttons Flush and modular: flat rear elements
RMQ-Titan units with a flush design are the perfect complement to the industry's move towards stylish front panels for machines.
These flush pushbuttons feature a modular design and are the perfect match for the RMQ-Titan series, flush contacts, and LED elements. Moreover, the flush transition between their operator and bezel make these units ideal when it comes to sleek looks and cutting-edge applications.
The flush contact and LED elements, which have a mounting depth of only 30 mm, are perfect for control panels in which every bit of space counts. These elements feature a one-of-a-kind modular design when it comes to operators, contacts, LED colors, and accessories, making it possible to make customer-specific changes in control panels in record time and without any extra effort.
Fast, flexible labelling – The Labeleditor High-precision settings made easy
Use the Labeleditor program to easily and conveniently create your own custom company-specific and project-specific labels, logos, and images for RMQ button plates.
www.eaton.eu/rmq
The M22-SWD encoder makes it possible to set extremely precise settings on machines by simply turning it and confirming. Moreover, its modular design, combined with a direct SmartWire-DT connection, allows for maximum installation flexibility and ease of diagnostics. The M22-SWD encoder also completely eliminates any potential extra costs that would normally be associated with the use of an encoder, such as those involved in establishing a connection to a PLC. And to top it all off, it is tremendously easy to use with gloves on.
EATON CA08103003Z-EN-INT 97
CA08103003Z_MOEM2015-EN.book Seite 98 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
System overview
RMQ-Titan pilot devicesSystem overview
2
3
1
21
2
3
20
4
4
5
6
4
Moeller® series
4
19
10
18
17
16
15
14
8
4
7
4
3
9
22
23
10
6
5
4
3
2
1
11 24
11
12
4-way selector switch actuators
Labels with label mounts
Mounting clamp
Contact/LED elements
Individual inscription
Surface mounting enclosure
7
9
8
10
11
12
Telescopic clip
Centring adapter
IVS top-hat rail adapter
Label mounts
Acoustic device
Buzzer
EATON CA08103003Z-EN-INT
17
18
15
16
13
14
13
Potentiometer
Controlled stop pushbuttons/ emergency-stop buttons
Indicator light
Key-operated actuators
Changeover switches
Button plates/lenses
19
20
21
22
23
24
Pushbutton actuators
Joystick
4-way pushbutton
Bezels
Accessories
SmartWire-DT ribbon cable
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 98 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
System overview
RMQ-Titan pilot devicesSystem overview
2
3
1
21
2
3
20
4
4
5
6
4
Moeller® series
4
19
10
18
17
16
15
14
8
4
7
4
3
9
22
23
10
6
5
4
3
2
1
98
4-way selector switch actuators
Labels with label mounts
Mounting clamp
Contact/LED elements
Individual inscription
Surface mounting enclosure
7
9
8
10
11
12
Telescopic clip
Centring adapter
IVS top-hat rail adapter
Label mounts
Acoustic device
Buzzer
EATON CORPORATION CA08103003Z-EN
17
18
15
16
13
14
11 24
11
12
13
Potentiometer
Controlled stop pushbuttons/ emergency-stop buttons
Indicator light
Key-operated actuators
Changeover switches
Button plates/lenses
23
24
21
22
19
20
Pushbutton actuators
Joystick
4-way pushbutton
Bezels
Accessories
SmartWire-DT ribbon cable
CA08103003Z_MOEM2015-EN.book Seite 99 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devicesDouble actuators
Double actuators
IP66
White lens
Actuators and indicator lights non-flush
Button plate
Actuators and indicator lights flush
Pushbutton actuator I and indicator light flush, pushbutton actuator 0 non-flush
Part no.
RMQ-Titan pilot devices
Article no.
Part no.
Momentary
M22-DDL-GR 216698
M22-DDL-GR-X1/X0 216700
M22-DDL-GR-GB1/GB0 216702
M22-DDL-WS 216704
M22-DDL-WS-X1/X0 216706
M22-DDL-WS-GB1/GB0 216708
M22-DDL-S-X4/X5
M22-DDL-S-X7/X7
218145
216710
M22-DDL-S-X226/X26 105227
M22-DDLF-GR-X1/X0 284814
M22-DDLF-WS-X1/X0 284816
M22-DDLM-GR-X1/X0 284830
M22-DDLM-WS-X1/X0 284832
Double actuators
Article no.
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 100 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
Pushbutton actuators, Mushroom-headed pushbutton
Button plate
Pushbutton actuators
IP67, IP69K
Flat
Part no.
Article no.
Part no.
Moeller® series
Article no.
Extended
-
Guard-ring -
Mushroom-headed pushbutton
IP67, IP69K
Notes
Pushbutton actuators, Mushroom-headed pushbutton
Mushroom
1) Stay-put/spring-return function can be changed on device
Momentary
M22-DP-S
M22-DP-R
M22-DP-G
M22-DP-Y
M22-DP-R-X0
M22-DP-G-X1
M22-DP-S-X0
M22-DP-W-X1
M22-DH-S
M22-DH-W
M22-DH-R
M22-DH-G
M22-DH-Y
M22-DH-B
M22-DH-R-X0
M22-DH-G-X1
M22-DH-S-X0
M22-DH-W-X1
Momentary
M22-D-S
M22-D-W
M22-D-R
M22-D-G
M22-D-Y
M22-D-B
M22-D-GR
M22-D-X
M22-D-R-X0
M22-D-G-X1
M22-D-S-X0
M22-D-W-X1
M22-DG-X
216636
216638
216641
216643
216646
216649
216655
216657
216659
216661
220921
216590
216592
216594
216596
216598
216600
132671
216602
216605
216607
216609
216611
Maintained 1)
M22-DR-S
M22-DR-W
M22-DR-R
M22-DR-G
M22-DR-Y
M22-DR-B
M22-DR-X
M22-DR-R-X0
M22-DR-G-X1
M22-DR-S-X0
M22-DR-W-X1
M22-DRH-S
M22-DRH-W
M22-DRH-R
M22-DRH-G
M22-DRH-Y
M22-DRH-B
M22-DRH-R-X0
M22-DRH-G-X1
M22-DRH-S-X0
M22-DRH-W-X1
216663
216665
216667
216669
216671
216673
216675
216677
216679
216681
216625
216628
216630
216632
216634
216613
216615
216617
216619
216621
216623
216712
216714
216716
216718
216720
216722
216724
216726
Maintained 1)
M22-DRP-S
M22-DRP-R
M22-DRP-G
M22-DRP-Y
M22-DRP-R-X0
M22-DRP-G-X1
M22-DRP-S-X0
M22-DRP-W-X1
216743
216745
216747
216749
216751
216753
216755
216757
CA08103003Z_MOEM2015-EN.book Seite 101 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devices Stop buttons, Selector switch actuators
Stop buttons
Diameter 38 mm
Base yellow
IP66, IP69K
Non-illuminated
Non-illuminated
Illuminated with LED element
Illuminated with LED element
Non-illuminated
Pull-to-release function
Turn-to-release function
Pull-to-release function
Turn-to-release function
Turn-to-release function
Mushroom head
RMQ-Titan pilot devices
Stop buttons, Selector switch actuators
Part no.
Article no.
M22S-PV
M22S-PVT
M22S-PVL
M22S-PVLT
M22Y-PVT
225528
271499
230962
271540
147403
Function:
= spring-return
= stay-put
Selector switch actuators
IP66
Stay-put/spring-return function, can be changed with coding parts M22-XC-Y
With rotary head 2 positions 40°
2 positions 60°
2 positions 60°
2 positions 60°
With thumb-grip
Notes
3 positions
3 positions
1)
1)
40° 40°
60° 60°
3 positions 1) 60° 60°
4 positions
2 positions
2 positions
2)
2 positions (V position)
3 positions
3 positions
4 positions
1)
1)
2)
4
0
3
0 1
0
2
0
40°
60°
60°
40° 40°
60° 60°
4
0
3
0 1
0
0
2
1)
2)
With plunger bridge for the middle contact
Not suitable for coding adapters
Use M22 ‐ A4 xing adapter → accessories
Button plate
AUTO HAND
-
-
-
-
-
Auto
0 Man.
Part no.
Article no.
M22-W
M22-WR
M22-WR-X92
M22-WR-X91
216853
216855
216857
216859
M22-W3
M22-WR3
M22-WR3-X94
M22-WR4
M22-WK
M22-WRK
M22-WKV
M22-WK3
M22-WRK3
M22-WRK4
216861
216863
226838
279419
216865
216867
216874
216870
216872
279431
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 101
CA08103003Z_MOEM2015-EN.book Seite 101 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devices Stop buttons, Selector switch actuators
Stop buttons
Diameter 38 mm
Base yellow
IP66, IP69K
Non-illuminated
Non-illuminated
Illuminated with LED element
Illuminated with LED element
Non-illuminated
Pull-to-release function
Turn-to-release function
Pull-to-release function
Turn-to-release function
Turn-to-release function
Mushroom head
RMQ-Titan pilot devices
Stop buttons, Selector switch actuators
Part no.
Article no.
M22S-PV
M22S-PVT
M22S-PVL
M22S-PVLT
M22Y-PVT
225528
271499
230962
271540
147403
Function:
= spring-return
= stay-put
Selector switch actuators
IP66
Stay-put/spring-return function, can be changed with coding parts M22-XC-Y
With rotary head 2 positions 40°
2 positions 60°
2 positions 60°
2 positions 60°
With thumb-grip
Notes
3 positions
3 positions
1)
1)
40° 40°
60° 60°
3 positions 1) 60° 60°
4 positions
2 positions
2 positions
2)
2 positions (V position)
3 positions
3 positions
4 positions
1)
1)
2)
4
0
3
0 1
0
2
0
40°
60°
60°
40° 40°
60° 60°
4
0
3
0 1
0
0
2
1)
2)
With plunger bridge for the middle contact
Not suitable for coding adapters
Use M22 ‐ A4 xing adapter → accessories
Button plate
AUTO HAND
-
-
-
-
-
Auto
0 Man.
Part no.
Article no.
M22-W
M22-WR
M22-WR-X92
M22-WR-X91
216853
216855
216857
216859
M22-W3
M22-WR3
M22-WR3-X94
M22-WR4
M22-WK
M22-WRK
M22-WKV
M22-WK3
M22-WRK3
M22-WRK4
216861
216863
226838
279419
216865
216867
216874
216870
216872
279431
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 102 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
Key-operated buttons, Joystick, Pushbuttons
RMQ-Titan pilot devices Key-operated buttons, Joystick, Pushbuttons
Key-operated buttons
IP66
Not suitable for master key systems
With 1 key
Stay-put/spring-return function, can be changed with coding parts M22-XC-Y
Key withdraw convertible with coding adapters M22-XC-...
2 positions
2 positions
40°
60°
3 positions
3 positions
40° 40°
60° 60°
Key withdrawable in position Part no.
Moeller® series
Article no.
I
-
-
-
0
0
0
0
-
II
I
M22-WS
M22-WRS
216881
216887
M22-WS3
M22-WRS3
216894
216900
Joystick
With metal shaft
IP66
Notes
Pushbuttons
Actuators non-flush
IP66
Function:
= spring-return
Description
= stay-put
Part no.
Article no.
2 positions
4 positions
With one operating point per operating direction
With 2 operating points per operating direction
With one operating point per operating direction
With 2 operating points per operating direction
With one operating point per operating direction
With one operating point per operating direction
With one operating point per operating direction
With 2 operating points per operating direction
M22-WJS2H
M22-WJS2H-2P 1)
M22-WJS2V
M22-WJS2V-2P
M22-WRJS2H
M22-WRJS2V
M22-WJS4
M22-WJS4-2P 1)
1)
178570
178565
178571
178564
178574
178575
178568
178563
With one operating point per operating direction M22-WRJS4 178566
1) These joysticks are combined with normal normally open contacts M22-K10 and NO early-make contacts M22-K10P.
4-fold
Opposing pushbuttons not mechanically interlocked
Part no.
M22-D4-S
Article no.
279411
4-fold
Opposing pushbuttons not mechanically interlocked
4-fold
Opposing pushbuttons mechanically interlocked
M22-D4-S-X7
M22-DI4-S-X7
286336
286338
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 103 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devices Indicator lights, Illuminated pushbutton actuators
Indicator lights
IP67, IP69K
Flush
Extended, conical
Lens
Without lens
RMQ-Titan pilot devices
Indicator lights, Illuminated pushbutton actuators
Part no.
Article no.
M22-L-W
M22-L-R
M22-L-G
M22-L-Y
M22-L-B
M22-L-A
M22-L-X
M22-LH-W
M22-LH-R
M22-LH-G
M22-LH-Y
M22-LH-B
M22-LH-A
216771
216772
216773
216774
216775
164374
216776
216778
216779
216780
216781
216782
164375
Illuminated pushbutton actuators
IP67, IP69K
Flush
Extended
Guard-ring
Notes
Button plate
Without button plate
Part no.
Article no.
momentary
M22-DL-W
M22-DL-R
M22-DL-G
M22-DL-Y
M22-DL-B
M22-DL-A
M22-DL-X
M22-DL-R-X0
M22-DL-G-X1
M22-DL-W-X0
M22-DL-W-X1
M22-DLH-W
M22-DLH-R
M22-DLH-G
M22-DLH-Y
M22-DLH-B
M22-DLH-A
M22-DLH-R-X0
M22-DLH-G-X1
M22-DLH-W-X0
M22-DLH-W-X1
M22-DGL-X
216922
216925
216927
216929
216931
167429
216933
216936
216938
216940
216942
216965
216967
216969
216971
216973
167433
216975
216977
216979
216981
230961
Part no.
Article no.
maintained 1)
M22-DRL-W
M22-DRL-R
M22-DRL-G
M22-DRL-Y
M22-DRL-B
M22-DRL-A
M22-DRL-X
M22-DRL-R-X0
M22-DRL-G-X1
M22-DRL-W-X0
M22-DRL-W-X1
M22-DRLH-W
M22-DRLH-R
M22-DRLH-G
M22-DRLH-Y
M22-DRLH-B
M22-DRLH-A
M22-DRLH-R-X0
M22-DRLH-G-X1
M22-DRLH-W-X0
M22-DRLH-W-X1
216944
216946
216948
216950
216952
167431
216954
216957
216959
216961
216963
216788
216789
216796
216799
216802
167435
216804
216805
216806
216807
Without button plate
1) Stay-put/spring-return function can be changed on device
EATON CORPORATION CA08103003Z-EN 103
CA08103003Z_MOEM2015-EN.book Seite 103 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devices Indicator lights, Illuminated pushbutton actuators
Indicator lights
IP67, IP69K
Flush
Extended, conical
Lens
Without lens
RMQ-Titan pilot devices
Indicator lights, Illuminated pushbutton actuators
Part no.
Article no.
M22-L-W
M22-L-R
M22-L-G
M22-L-Y
M22-L-B
M22-L-A
M22-L-X
M22-LH-W
M22-LH-R
M22-LH-G
M22-LH-Y
M22-LH-B
M22-LH-A
216771
216772
216773
216774
216775
164374
216776
216778
216779
216780
216781
216782
164375
Illuminated pushbutton actuators
IP67, IP69K
Flush
Extended
Button plate
Without button plate
Part no.
Article no.
momentary
M22-DL-W
M22-DL-R
M22-DL-G
M22-DL-Y
M22-DL-B
M22-DL-A
M22-DL-X
M22-DL-R-X0
M22-DL-G-X1
M22-DL-W-X0
M22-DL-W-X1
M22-DLH-W
M22-DLH-R
M22-DLH-G
M22-DLH-Y
M22-DLH-B
M22-DLH-A
M22-DLH-R-X0
M22-DLH-G-X1
M22-DLH-W-X0
M22-DLH-W-X1
M22-DGL-X
216922
216925
216927
216929
216931
167429
216933
216936
216938
216940
216942
216965
216967
216969
216971
216973
167433
216975
216977
216979
216981
230961 Guard-ring Without button plate
Notes 1) Stay-put/spring-return function can be changed on device
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Part no.
Article no.
maintained 1)
M22-DRL-W
M22-DRL-R
M22-DRL-G
M22-DRL-Y
M22-DRL-B
M22-DRL-A
M22-DRL-X
M22-DRL-R-X0
M22-DRL-G-X1
M22-DRL-W-X0
M22-DRL-W-X1
M22-DRLH-W
M22-DRLH-R
M22-DRLH-G
M22-DRLH-Y
M22-DRLH-B
M22-DRLH-A
M22-DRLH-R-X0
M22-DRLH-G-X1
M22-DRLH-W-X0
M22-DRLH-W-X1
216944
216946
216948
216950
216952
167431
216954
216957
216959
216961
216963
216788
216789
216796
216799
216802
167435
216804
216805
216806
216807
CA08103003Z_MOEM2015-EN.book Seite 104 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
Illuminated selector switch actuator
RMQ-Titan pilot devicesIlluminated selector switch actuator
Function:
= spring-return
= stay-put
Illuminated selector switch actuator
With thumb-grip
IP66
Stay-put/spring-return function, can be changed with coding parts M22-XC-Y
2 positions 40°
3 positions
60°
60°
60°
60°
40° 40°
40° 40°
40° 40°
40° 40°
40° 40°
60° 60°
60° 60°
60° 60°
60° 60°
60° 60°
40°
40°
40°
40°
60°
60°
60°
60°
60°
60°
Part no.
Moeller® series
Article no.
M22-WLK-W
M22-WLK-R
M22-WLK-G
M22-WLK-Y
M22-WLK-B
M22-WRLK-W
M22-WRLK-R
M22-WRLK-G
M22-WRLK-Y
M22-WRLK-B
M22-WLKV-W
M22-WLKV-R
M22-WLKV-G
M22-WLKV-Y
M22-WLKV-B
M22-WLK3-W
M22-WLK3-R
M22-WLK3-G
M22-WLK3-Y
M22-WLK3-B
M22-WRLK3-W
M22-WRLK3-R
M22-WRLK3-G
M22-WRLK3-Y
M22-WRLK3-B
216835
216837
216839
216841
216843
216845
216847
216849
216851
284394
284395
284396
284397
216833
216812
216814
216816
216818
216820
216823
216825
216827
216829
216831
284393
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 105 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devices Contact elements, Mounting adapter
Contacts
N/O = Normally open
N/C = Normally closed 1)
Part no.
RMQ-Titan pilot devices
Contact elements, Mounting adapter
Article no.
Part no.
Article no.
Contact elements
IP20
Single contact
Double contact
Front fixing
Base fixing
Front fixing
Screw terminals
1 N/O
-
1 N/O
-
-
1 NC
M22-K10
-
-
1 NO early-make -
1 NC M22-K01
M22-K10P
1 NC late-break M22-K01D
M22-KC10
M22-KC01
-
2 N/O
1 N/O
-
2 NC
1 NC
216376
216378
110835
262165
216380
216382
Cage Clamp 2)
M22-CK10
M22-CK01
M22-CK01D
M22-CKC10
M22-CKC01
M22-CK20
M22-CK02
M22-CK11
216384
216385
262510
216386
216387
107898
107899
107940
Self-monitoring contact elements 3)
Front fixing
Base fixing
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 NC
2 NC
1 NC
2 NC
3 NC
2 N/O 2 NC
Combination of contact element with screw terminals, M22-A fixing adapter and M22-XSMC indication contact actuator.
3)
M22-K01SMC10
M22-K02SMC10
121472
121474
M22-KC01SMC10 121473
M22-KC02SMC10 121720
M22-KC03SMC10 173028
M22-KC12SMC10 173029
Notes
Front fixing 1 N/O
2 N/O
3 NC
2 NC
M22-AK03SMC10 173026
M22-AK12SMC10 173027
1)
2)
3)
= safety function, by positive opening to IEC/EN 60947-5-1
Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/Minden, Germany
The N/O is actuated when mounted on the pushbutton.
Part no.
M22-A
Mounting adapter
Mounting clamp (front mounting) for 3-contact LED elements
-
Mounting clamp (front mounting) for 4-contact LED elements
-
Front fixing
For 2 function elements M22-SWD-K22…
For use with M22-WR4, -WRJ4, -D4 in conjunction with M22-(SWD)-K
M22-A4
Article no.
216374
279437
M22-SWD-A4 116016
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 106 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
LED elements, Potentiometer, Acoustic device
Rated operational voltage
U e
V
LED elements
IP20
Front fixing
Base fixing 2)
Notes
Part no.
Article no.
Part no.
Moeller® series
Article no.
12 - 30 V AC/DC, 50/60 Hz
Screw terminals
M22-LED-W
M22-LED-R
M22-LED-G
M22-LED-B
85 - 264 V AC, 50/60 Hz
12 - 30 V AC/DC, 50/60 Hz
M22-LED230-W
M22-LED230-R
M22-LED230-G
M22-LED230-B
M22-LEDC-W
M22-LEDC-R
M22-LEDC-G
M22-LEDC-B
85 - 264 V AC, 50/60 Hz M22-LEDC230-W 216566
M22-LEDC230-R
M22-LEDC230-G
M22-LEDC230-B
216567
216568
218060
1)
2)
Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/Minden, Germany
Can be used for M22-I... surface mounting enclosure
216557
216558
216559
218057
216563
216564
216565
218059
216560
216561
216562
218058
Cage Clamp 1)
M22-CLED-W
M22-CLED-R
M22-CLED-G
M22-CLED-B
216569
216570
216571
218061
M22-CLED230-W 216575
M22-CLED230-R 216576
M22-CLED230-G
M22-CLED230-B
216577
218063
M22-CLEDC-W
M22-CLEDC-R
M22-CLEDC-G
M22-CLEDC-B
216572
216573
216574
218062
M22-CLEDC230-W 216578
M22-CLEDC230-R 216579
M22-CLEDC230-G 216580
M22-CLEDC230-B 218064
Part no.
Article no.
Potentiometer
IP66
1
2.2
4.7
10
47
100
470
Impedance
R k Ω
M22-R1K
M22-R2K2
M22-R4K7
M22-R10K
M22-R47K
M22-R100K
M22-R470K
229489
171157
229490
229491
229492
229493
229494
Part no.
M22-AMC
Article no.
229015
Acoustic device
Without buzzer
With BA 9s lamp socket
IP40
Buzzer for acoustic device
Continuous tone, 18 - 30 V AC/DC
Pulsed tone, 24 V DC (+10 %/-15 %)
RMQ-Titan pilot devices LED elements, Potentiometer, Acoustic device
EATON CA08103003Z-EN-INT
M22-XAM
M22-XAMP
229025
229028
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 107 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devicesAccessories
Legend holder
IP66
For use with
For actuators
For double actuators
Insert label
-
Bulkhead interface, RJ45 socket
IP65 (with closed cover)
IP20 (with plug connected)
Front mounting
RJ45, socket to socket 8/8, CAT5e
Front mounting
USB 3.0, Type A socket to socket
Bulkhead interface, USB socket
IP65 (with closed cover)
IP20 (with plug connected)
Front mounting
Prefabricated cable with permanently connected USB 2.0 Type A plug, 60 cm.
Front mounting
Type A socket with prefabricated cable (150 cm) with permanently connected USB 3.0, Type A plug
-
-
-
-
Width mm
30
30
27
-
-
-
-
18
50
75
Height mm
RMQ-Titan pilot devices
Accessories
Part no.
Article no.
M22S-ST-X
M22S-STDD-X
216392
216394
M22-XST
M22-RJ45-SA 107413
M22-USB
216480
147539
M22-USB-SA
M22-USB-SA-150
107412
147543
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 108 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
Complete units
RMQ-Titan pilot devicesComplete units
Number of locations
Surface mounting enclosure
With high-grade steel screws
1
2
3
4
6
Degree of Protection
IP67, IP69K
IP67, IP69K
IP67, IP69K
IP67, IP69K
IP66
Part no.
M22-I1
M22-I2
M22-I3
M22-I4
M22-I6
Moeller® series
Article no.
216535
216537
216538
216539
216540
Pushbutton actuators
IP67, IP69K
1
1
2
3
Key-operated buttons
IP66
1
Number of locations
Contacts
1 NC
1 NC
2 NC
3 NC
1 NC
1 N/O
1 N/O
2 N/O
3 N/O
1 N/O
Key withdrawable in position
Button plate Part no.
-
-
-
-
0
-
-
-
-
I -
Article no.
M22-D-G-X1/KC11/I
M22-D-R-X0/KC11/I
M22-I2-M1
M22-I3-M1
216522
216521
216529
216532
M22-WRS/KC11/I 216526
Notes = safety function, by positive opening to IEC/EN 60947-5-1
CA08103003Z_MOEM2015-EN.book Seite 109 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devicesControlled stop pushbuttons/emergency-stop buttons
Part no.
RMQ-Titan pilot devices
Controlled stop pushbuttons/emergency-stop buttons
Article no.
Part no.
Article no.
Controlled stop pushbuttons/emergency-stop buttons
Tamper-proof according to ISO 13850/EN 418
IP66, IP69K
Mushroom-shaped
Palm-tree shape
Notes
Pull-to-release function Non-illuminated
Non-illuminated
Illuminated with
LED element
Turn-to-release function Non-illuminated
Key-release
Illuminated with
LED element
Non-illuminated
Diameter 38 mm
M22-PV-ESS
M22-PV
M22-PVL
M22-PVT
M22-PVLT
M22-PVS
178983
216876
216878
263467
263469
216879
Pull-to-release function Non-illuminated
Illuminated with
LED element
Non-illuminated
Turn-to-release function Non-illuminated
Illuminated with
LED element
Non-illuminated
Key-release Non-illuminated
Non-illuminated
Diameter 45 mm
M22-PV45P
M22-PVL45P
M22-PV45P-MPI 1)
152862
152860
152863
M22-PVT45P
M22-PVLT45P
121462
121460
M22-PVT45P-MPI 1) 121463
M22-PVS45P-MS1 121468
M22-PVS45P-RS 121466
Max. number of contacts: four M22-(C)K01, …10 or two M22-(C)K02, …20, …11
1) With mechanical switch position indication
Switch position indicator red → pushbutton actuated
Switch position indication green → pushbutton released
Diameter 60 mm
M22-PV60P
M22-PVL60P
M22-PV60P-MPI 1)
152864
152861
152865
M22-PVT60P
M22-PVLT60P
121464
121461
M22-PVT60P-MPI 1) 121465
M22-PVS60P-MS1 121469
M22-PVS60P-RS 121467
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 109
CA08103003Z_MOEM2015-EN.book Seite 108 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
Complete units
RMQ-Titan pilot devicesComplete units
Number of locations
Surface mounting enclosure
With high-grade steel screws
1
2
3
4
6
Degree of Protection
IP67, IP69K
IP67, IP69K
IP67, IP69K
IP67, IP69K
IP66
Part no.
M22-I1
M22-I2
M22-I3
M22-I4
M22-I6
Moeller® series
Article no.
216535
216537
216538
216539
216540
Pushbutton actuators
IP67, IP69K
1
1
2
3
Key-operated buttons
IP66
1
Number of locations
Contacts
1 NC
1 NC
2 NC
3 NC
1 NC
1 N/O
1 N/O
2 N/O
3 N/O
1 N/O
Key withdrawable in position
Button plate Part no.
-
-
-
-
0
-
-
-
-
I -
Article no.
M22-D-G-X1/KC11/I
M22-D-R-X0/KC11/I
M22-I2-M1
M22-I3-M1
216522
216521
216529
216532
M22-WRS/KC11/I 216526
Notes = safety function, by positive opening to IEC/EN 60947-5-1
CA08103003Z_MOEM2015-EN.book Seite 109 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devicesControlled stop pushbuttons/emergency-stop buttons
Part no.
RMQ-Titan pilot devices
Controlled stop pushbuttons/emergency-stop buttons
Article no.
Part no.
Article no.
Controlled stop pushbuttons/emergency-stop buttons
Tamper-proof according to ISO 13850/EN 418
IP66, IP69K
Mushroom-shaped
Palm-tree shape
Notes
Pull-to-release function Non-illuminated
Non-illuminated
Illuminated with
LED element
Turn-to-release function Non-illuminated
Key-release
Illuminated with
LED element
Non-illuminated
Diameter 38 mm
M22-PV-ESS
M22-PV
M22-PVL
M22-PVT
M22-PVLT
M22-PVS
178983
216876
216878
263467
263469
216879
Pull-to-release function Non-illuminated
Illuminated with
LED element
Non-illuminated
Turn-to-release function Non-illuminated
Illuminated with
LED element
Non-illuminated
Key-release Non-illuminated
Non-illuminated
Diameter 45 mm
M22-PV45P
M22-PVL45P
M22-PV45P-MPI 1)
152862
152860
152863
M22-PVT45P
M22-PVLT45P
121462
121460
M22-PVT45P-MPI 1) 121463
M22-PVS45P-MS1 121468
M22-PVS45P-RS 121466
Max. number of contacts: four M22-(C)K01, …10 or two M22-(C)K02, …20, …11
1) With mechanical switch position indication
Switch position indicator red → pushbutton actuated
Switch position indication green → pushbutton released
Diameter 60 mm
M22-PV60P
M22-PVL60P
M22-PV60P-MPI 1)
152864
152861
152865
M22-PVT60P
M22-PVLT60P
121464
121461
M22-PVT60P-MPI 1) 121465
M22-PVS60P-MS1 121469
M22-PVS60P-RS 121467
108 EATON CORPORATION CA08103003Z-EN Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 110 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
Complete units EMERGENCY STOP/EMERGENCY SWITCHING OFF
RMQ-Titan pilot devicesComplete units EMERGENCY STOP/EMERGENCY SWITCHING OFF
For use with
Surface mounting enclosure
With high-grade steel screws
IP67, IP69K
-
M22-XPV60… illuminated ring
Part no.
Moeller® series
Article no.
M22-IY1
M22-IY1-XPV60
216536
167798
Lock mechanism
Contacts
N/O = Normally open
Controlled stop pushbuttons/emergency-stop buttons
Tamper-proof according to ISO 13850/EN 418
Non-illuminated
Mushroom-shaped
Pull-to-release function 1 N/O
N/C = Normally closed
1 NC
Part no.
Diameter 38 mm
M22-PV/KC11/IY
Article no.
Part no.
216525
Article no.
Key-release 1 N/O 1 NC M22-PVS/KC11/IY 216523
Palm-tree shape
Key-release MS1
MS1
-
1 N/O
2 NC
1 NC
Diameter 45 mm
C22-PVS45P-MS1-K02 121619
C22-PVS45P-MS1-K11 121618
Diameter 60 mm
C22-PVS60P-MS1-K02 121621
C22-PVS60P-MS1-K11 121620
Turn-to-release function
-
-
1 N/O
2 NC
1 NC
C22-PVT45P-K02
C22-PVT45P-K11
121611
121610
C22-PVT60P-K02
C22-PVT60P-K11
121613
121612
Notes = safety function, by positive opening to IEC/EN 60947-5-1
CA08103003Z_MOEM2015-EN.book Seite 111 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devicesEmergency stop accessories
Name
Emergency stop labels
IP66
Symbol (5638) for CONTROLLED
STOP
Symbol (5638) for CONTROLLED
STOP
Symbol (5638) for CONTROLLED
STOP
Symbol (5638) for CONTROLLED
STOP
Symbol (5638) for CONTROLLED
STOP
Emergency-stop labels
IP66
Form
Diameter = 90 mm
Diameter = 60 mm
33 x 50 mm
33 x 50 mm
50 x 50 mm
Diameter = 90 mm
Diameter = 60 mm
NOT-AUS 33 x 50 mm
NOT-AUS
50 x 50 mm
-
-
-
-
-
Language
RMQ-Titan pilot devices
Emergency stop accessories
Part no.
Article no.
M22-XAK-ESS
M22-XBK-ESS
M22-XZK-ESS
M22-XZK-ESS2
M22-XYK-ESS
180469
180472
180470
180474
180471 de, en, fr, it de, en, fr, it
M22-XAK1
M22-XBK1 de M22-XZK-D99
216465
216483
216471 de, en, fr, it M22-XYK1 216484
Rated operational voltage
U e
V
Diameter d mm
LED-Luminous ring
IP67, IP69K
Three groups of 4 LEDs each (series-connected), can be actuated separately (e.g. for continuous light)
One group of 8 LEDs (series-connected)
One group of 8 LEDs (series-connected)
24 V AC/DC
120 V AC
230 V AC
60 mm
60 mm
60 mm
Guard-ring
IP65
Protection against accidental actuation -
Sealable shroud
IP65
For devices with mushroom diameter 38 mm
Transparent with collapse point, can be reused after
Emergency-Stop, Emergency switching off operation.
With grid 30 x 50 mm the drilling dimensions can be closed with M22(S)-B blanking plug
-
Part no.
M22-XPV60-Y-24
M22-XPV60-Y-120
M22-XPV60-Y-230
121477
121476
138280
M22-XGPV
M22-PL-PV
Article no.
231273
216397
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 111
CA08103003Z_MOEM2015-EN.book Seite 110 Donnerstag, 7. April 2016 12:02 12
RMQ-Titan pilot devices
Complete units EMERGENCY STOP/EMERGENCY SWITCHING OFF
RMQ-Titan pilot devicesComplete units EMERGENCY STOP/EMERGENCY SWITCHING OFF
For use with
Surface mounting enclosure
With high-grade steel screws
IP67, IP69K
-
M22-XPV60… illuminated ring
Part no.
Moeller® series
Article no.
M22-IY1
M22-IY1-XPV60
216536
167798
Lock mechanism
Contacts
N/O = Normally open
Controlled stop pushbuttons/emergency-stop buttons
Tamper-proof according to ISO 13850/EN 418
Non-illuminated
Mushroom-shaped
Pull-to-release function 1 N/O
N/C = Normally closed
1 NC
Part no.
Diameter 38 mm
M22-PV/KC11/IY
Article no.
Part no.
216525
Article no.
Key-release 1 N/O 1 NC M22-PVS/KC11/IY 216523
Palm-tree shape
Key-release MS1
MS1
-
1 N/O
2 NC
1 NC
Diameter 45 mm
C22-PVS45P-MS1-K02 121619
C22-PVS45P-MS1-K11 121618
Diameter 60 mm
C22-PVS60P-MS1-K02 121621
C22-PVS60P-MS1-K11 121620
Turn-to-release function
-
-
1 N/O
2 NC
1 NC
C22-PVT45P-K02
C22-PVT45P-K11
121611
121610
C22-PVT60P-K02
C22-PVT60P-K11
121613
121612
Notes = safety function, by positive opening to IEC/EN 60947-5-1
CA08103003Z_MOEM2015-EN.book Seite 111 Donnerstag, 7. April 2016 12:02 12
Moeller® series
RMQ-Titan pilot devicesEmergency stop accessories
Name
Emergency stop labels
IP66
Symbol (5638) for CONTROLLED
STOP
Symbol (5638) for CONTROLLED
STOP
Symbol (5638) for CONTROLLED
STOP
Symbol (5638) for CONTROLLED
STOP
Symbol (5638) for CONTROLLED
STOP
Emergency-stop labels
IP66
Form
Diameter = 90 mm
Diameter = 60 mm
33 x 50 mm
33 x 50 mm
50 x 50 mm
Diameter = 90 mm
Diameter = 60 mm
NOT-AUS 33 x 50 mm
NOT-AUS
50 x 50 mm
-
-
-
-
-
Language
RMQ-Titan pilot devices
Emergency stop accessories
Part no.
Article no.
M22-XAK-ESS
M22-XBK-ESS
M22-XZK-ESS
M22-XZK-ESS2
M22-XYK-ESS
180469
180472
180470
180474
180471 de, en, fr, it de, en, fr, it
M22-XAK1
M22-XBK1 de M22-XZK-D99
216465
216483
216471 de, en, fr, it M22-XYK1 216484
Rated operational voltage
U e
V
Diameter d mm
LED-Luminous ring
IP67, IP69K
Three groups of 4 LEDs each (series-connected), can be actuated separately (e.g. for continuous light)
One group of 8 LEDs (series-connected)
One group of 8 LEDs (series-connected)
24 V AC/DC
120 V AC
230 V AC
60 mm
60 mm
60 mm
Guard-ring
IP65
Protection against accidental actuation -
Sealable shroud
IP65
For devices with mushroom diameter 38 mm
Transparent with collapse point, can be reused after
Emergency-Stop, Emergency switching off operation.
With grid 30 x 50 mm the drilling dimensions can be closed with M22(S)-B blanking plug
-
Part no.
M22-XPV60-Y-24
M22-XPV60-Y-120
M22-XPV60-Y-230
121477
121476
138280
M22-XGPV
M22-PL-PV
Article no.
231273
216397
110 EATON CORPORATION CA08103003Z-EN Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 112 Donnerstag, 7. April 2016 12:02 12
RMQ pilot devices
compact
solution
Pushbutton actuators, Indicator lights Moeller® series
Pushbutton actuators, Indicator lights
Momentary Maintained
Complete unit
IP66, IP67, IP69K (front)
IP65 (on rear)
M12A plug with cable (black)
Flat
Pushbutton actuators
0.5
1
0.5
1
0.5
1
0.5
1
Without button plate
Without button plate
0.5
1
0.5
1
0.5
1
0.5
1
0.5
Without button plate
Without button plate
Without button plate
Without button plate
Without button plate
Without button plate
Without button plate
1
Illuminated pushbutton actuators
Rated operational voltage LED: 24 V AC/DC
0.5
Without button plate
1
0.5
1
0.5
1
0.5
1
Cable
Length m
Indicator lights
Rated operational voltage LED: 24 V AC/DC
0.5
Lens
1
0.5
1
0.5
1
0.5
1
0.5
1
Notes
Cable
Length m
Button plate
-
-
-
-
-
-
-
-
-
-
Contacts
N/C =
Normally closed 1)
-
-
-
-
-
-
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
-
-
1 NC
1 NC
2 NC
2 NC
-
-
-
-
-
-
1 NC
1 NC
-
-
-
-
-
-
-
-
-
-
N/O =
Normally open
-
-
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
-
-
1 N/O
1 N/O
-
-
-
-
-
-
1 N/O
1 N/O
2 N/O
2 N/O
Part no.
C22-D-G-K10-P3
C22-D-G-K10-P5
C22-D-W-K10-P3
C22-D-W-K10-P5
C22-D-X-K10-P3
C22-D-X-K10-P5
C22-D-R-K01-P3
C22-D-R-K01-P5
C22-D-S-K01-P3
C22-D-S-K01-P5
C22-D-X-K01-P3
C22-D-X-K01-P5
C22-D-X-K11-P3
C22-D-X-K11-P5
C22-D-X-K20-P3
C22-D-X-K20-P5
C22-D-X-K02-P3
C22-D-X-K02-P5
C22-L-B-24-P3
C22-L-B-24-P5
C22-L-G-24-P3
C22-L-G-24-P5
C22-L-R-24-P3
C22-L-R-24-P5
C22-L-W-24-P3
C22-L-W-24-P5
C22-L-Y-24-P3
C22-L-Y-24-P5
1) = safety function, by positive opening to IEC/EN 60947-5-1
Article no.
Part no.
C22-DL-B-K10-24-P3 181624
C22-DL-B-K10-24-P5 181298
C22-DL-G-K10-24-P3 181625
C22-DL-G-K10-24-P5 181300
C22-DL-W-K10-24-P3 181627
C22-DL-W-K10-24-P5 181307
C22-DL-R-K01-24-P3 181626
C22-DL-R-K01-24-P5 181303
181632
181041
181635
181047
181607
181051
181633
181043
181634
181045
181605
181049
181608
181052
181609
181053
181606
181050
181619
181137
181620
181139
181621
181141
181622
181059
181623
181061
C22-DR-G-K10-P3
C22-DR-G-K10-P5
C22-DR-W-K10-P3
C22-DR-W-K10-P5
C22-DR-X-K10-P3
C22-DR-X-K10-P5
C22-DR-R-K01-P3
C22-DR-R-K01-P5
C22-DR-S-K01-P3
C22-DR-S-K01-P5
C22-DR-X-K01-P3
C22-DR-X-K01-P5
C22-DR-X-K11-P3
C22-DR-X-K11-P5
C22-DR-X-K20-P3
C22-DR-X-K20-P5
C22-DR-X-K02-P3
C22-DR-X-K02-P5
Article no.
C22-DRL-B-K10-24-P3 181628
C22-DRL-B-K10-24-P5 181364
C22-DRL-G-K10-24-P3 181629
C22-DRL-G-K10-24-P5 181366
C22-DRL-W-K10-24-P3 181631
C22-DRL-W-K10-24-P5 181370
C22-DRL-R-K01-24-P3 181630
C22-DRL-R-K01-24-P5 181368
181610
181079
181613
181085
181616
181089
181611
181081
181612
181083
181614
181087
181617
181090
181618
181091
181615
181088
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 113 Donnerstag, 7. April 2016 12:02 12
Moeller® series
System overview
8
7
6
5
1 - 4 Operator only with button
Contact elements
BA9s base
Enclosure base
Indicator light (optional)
1
2
5
3
6
7
Foot and palm switches FAK
System overview
8
4
Function
Foot and palm switches, IP67, IP69K
Momentary
Colour
Button Enclosure top
Enclosure base
Contacts
= safety function, by positive opening to IEC/EN 60947-5-1
N/O = Normally open
N/C = Normally closed
Part no.
Article no.
1 N/O 1 NC FAK-S/KC11/I
229749
Momentary 1 N/O 1 NC FAK-R/KC11/I
229746
Maintained
-
-
1 N/O
1 NC
1 NC
2 NC
FAK-R/V/KC01/IY
229747
FAK-R/V/KC11/IY
229748
FAK-R/V/KC02/IY
256790
EATON CORPORATION CA08103003Z-EN 113
CA08103003Z_MOEM2015-EN.book Seite 112 Donnerstag, 7. April 2016 12:02 12
RMQ pilot devices
compact
solution
Pushbutton actuators, Indicator lights Moeller® series
Pushbutton actuators, Indicator lights
Momentary Maintained
Complete unit
IP66, IP67, IP69K (front)
IP65 (on rear)
M12A plug with cable (black)
Flat
Pushbutton actuators
0.5
1
0.5
1
0.5
1
0.5
1
Without button plate
Without button plate
0.5
1
0.5
1
0.5
1
0.5
1
0.5
Without button plate
Without button plate
Without button plate
Without button plate
Without button plate
Without button plate
Without button plate
1
Illuminated pushbutton actuators
Rated operational voltage LED: 24 V AC/DC
0.5
Without button plate
1
0.5
1
0.5
1
0.5
1
Cable
Length m
Indicator lights
Rated operational voltage LED: 24 V AC/DC
0.5
Lens
1
0.5
1
0.5
1
0.5
1
0.5
1
Notes
Cable
Length m
Button plate
-
-
-
-
-
-
-
-
-
-
Contacts
N/C =
Normally closed 1)
-
-
-
-
-
-
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
-
-
1 NC
1 NC
2 NC
2 NC
-
-
-
-
-
-
1 NC
1 NC
-
-
-
-
-
-
-
-
-
-
N/O =
Normally open
-
-
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
-
-
1 N/O
1 N/O
-
-
-
-
-
-
1 N/O
1 N/O
2 N/O
2 N/O
Part no.
C22-D-G-K10-P3
C22-D-G-K10-P5
C22-D-W-K10-P3
C22-D-W-K10-P5
C22-D-X-K10-P3
C22-D-X-K10-P5
C22-D-R-K01-P3
C22-D-R-K01-P5
C22-D-S-K01-P3
C22-D-S-K01-P5
C22-D-X-K01-P3
C22-D-X-K01-P5
C22-D-X-K11-P3
C22-D-X-K11-P5
C22-D-X-K20-P3
C22-D-X-K20-P5
C22-D-X-K02-P3
C22-D-X-K02-P5
C22-L-B-24-P3
C22-L-B-24-P5
C22-L-G-24-P3
C22-L-G-24-P5
C22-L-R-24-P3
C22-L-R-24-P5
C22-L-W-24-P3
C22-L-W-24-P5
C22-L-Y-24-P3
C22-L-Y-24-P5
1) = safety function, by positive opening to IEC/EN 60947-5-1
Article no.
Part no.
C22-DL-B-K10-24-P3 181624
C22-DL-B-K10-24-P5 181298
C22-DL-G-K10-24-P3 181625
C22-DL-G-K10-24-P5 181300
C22-DL-W-K10-24-P3 181627
C22-DL-W-K10-24-P5 181307
C22-DL-R-K01-24-P3 181626
C22-DL-R-K01-24-P5 181303
181632
181041
181635
181047
181607
181051
181633
181043
181634
181045
181605
181049
181608
181052
181609
181053
181606
181050
181619
181137
181620
181139
181621
181141
181622
181059
181623
181061
C22-DR-G-K10-P3
C22-DR-G-K10-P5
C22-DR-W-K10-P3
C22-DR-W-K10-P5
C22-DR-X-K10-P3
C22-DR-X-K10-P5
C22-DR-R-K01-P3
C22-DR-R-K01-P5
C22-DR-S-K01-P3
C22-DR-S-K01-P5
C22-DR-X-K01-P3
C22-DR-X-K01-P5
C22-DR-X-K11-P3
C22-DR-X-K11-P5
C22-DR-X-K20-P3
C22-DR-X-K20-P5
C22-DR-X-K02-P3
C22-DR-X-K02-P5
Article no.
C22-DRL-B-K10-24-P3 181628
C22-DRL-B-K10-24-P5 181364
C22-DRL-G-K10-24-P3 181629
C22-DRL-G-K10-24-P5 181366
C22-DRL-W-K10-24-P3 181631
C22-DRL-W-K10-24-P5 181370
C22-DRL-R-K01-24-P3 181630
C22-DRL-R-K01-24-P5 181368
181610
181079
181613
181085
181616
181089
181611
181081
181612
181083
181614
181087
181617
181090
181618
181091
181615
181088
112 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 113 Donnerstag, 7. April 2016 12:02 12
Moeller® series
System overview
8
7
6
5
1 - 4 Operator only with button
Contact elements
BA9s base
Enclosure base
Indicator light (optional)
1
2
5
3
6
7
Foot and palm switches FAK
System overview
8
4
Function
Foot and palm switches, IP67, IP69K
Momentary
Colour
Button Enclosure top
Enclosure base
Contacts
= safety function, by positive opening to IEC/EN 60947-5-1
N/O = Normally open
N/C = Normally closed
Part no.
Article no.
1 N/O 1 NC FAK-S/KC11/I
229749
Momentary 1 N/O 1 NC FAK-R/KC11/I
229746
Maintained
-
-
1 N/O
1 NC
1 NC
2 NC
FAK-R/V/KC01/IY
229747
FAK-R/V/KC11/IY
229748
FAK-R/V/KC02/IY
256790
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
SL4
40 mm
SL7
70 mm
Implement efficient signaling and see your equipment's availability soar
Catalog download: www.eaton.eu/catalog
IP66 www.eaton.eu/signaltower
Signal towers are just as essential to the smooth and safe operation of machines and systems as they are at airports and supermarkets. Moreover, the tasks they have to perform are as varied as the locations where they have to be used. This is why Eaton has designed its signal towers in such a way as to be able to accommodate extremely versatile light and acoustic modules. On top of this, their high IP66 degree of protection ensures that they can be used virtually anywhere.
In terms of signaling systems, light intensity and signal strength are as crucial to a system's efficiency as are the speed and ease with which complete towers can be assembled and disassembled, e.g., in order to transport a machine.
Moreover, this efficiency can be increased even further by effectively integrating signal towers into an automation solution. Within this context, a
SmartWire-DT connection not only significantly reduces wiring complexity, but also considerably enhances a system's communication capabilities. Intelligent switchgear can send alarm messages through the system – when, for example, overloading is imminent – in order to avoid stops and downtimes.
Following these signals, signal towers can output their own clearly recognizable signals, thus ensuring higher machine and system availability.
114 EATON CA08103003Z-EN-INT
Two signal tower configurations: SL4 and SL7
The signal towers are available with a compact diameter of
40 mm or with a standard diameter of 70 mm. In this way
Eaton provides an optimal solution for your signaling tasks, even in places where space is scarce.
Seamless style
Actuators and indicator lamps have a decisive impact on a machine's appearance. In fact, they are the first thing an operator notices. Because of this, Eaton has designed these elements with a common style, featuring such appealing design elements as sleek, smoothly rounded shapes.
Significantly brighter and louder signals
All six lamp modules are available with filament lamps, continuous light LEDs, flashing LEDs, strobe LEDs, or high-performance LEDs. This way, the modules' brightness and colors can be adapted to the specific needs of customers and to varying international market requirements. The same holds true for the acoustic modules. 8 different signals and volume that can be adjusted up to 100 dB allow for optimal adaptation to any ambient conditions.
Extremely flexible mounting options
Our new signal towers can be installed in any of 11 different ways. Not only can the cup-shaped base be mounted on the side of equipment, but it can also be mounted directly in a variety of other configurations. If there is not enough clearance to the ceiling, for example, the modules can be installed horizontally. Tubes with lengths of 100, 250, 400 and 800 mm, make the system even more flexible.
www.eaton.eu/selectiontools a b c Assemble and disassemble in a matter of seconds
Signal towers can be disassembled in order to transport the corresponding machine. With
Eaton's rapid mounting system, this can be done in a matter of seconds: a) Loosen the mounting ring.
b) Remove the signal tower.
c) Put the protection cap on. You are ready to go!
Re-assembling and mounting the signal tower, both electrically and mechanically, is just as simple.
EATON CA08103003Z-EN-INT 115
CA08103003Z_MOEM2015-EN.book Seite 116 Donnerstag, 7. April 2016 12:02 12
Signal towers SL7, SL4
System overview
5
6
6
5
5
1
3
2
4
8
8
Moeller® series
6
6
6
6
6
6 6
6
7
1
3
2
4
System overview
Card for filament lamp, continuous light
Module with LED/high power LED, continuous light
Card with LED, flashing light
Module with LED/high power LED, strobe light
EATON CA08103003Z-EN-INT
8
7
6
8
5 Acoustic module
Base module
Base module with SWD connection
Accessory consideration
8
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 117 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Complete devices, Light modules
Rated operational voltage
U e
V
Number of modules
IP66 complete units
Continuous light, LED, IP66, Base module with foot and 100 mm tube
24 V AC/DC 2
Colour
3
Module width
70 mm
Part no.
Article no.
Signal towers
Complete devices, Light modules
Module width
40 mm
Part no.
Article no.
SL7-100-L-RG-24LED
171424
SL7-100-L-RYG-24LED
171425
SL4-100-L-RG-24LED
171295
SL4-100-L-RYG-24LED
171296
Customised complete unit
Order on request
-
Rated operational voltage 1)
U e
V
Module with LED, IP66
24 V AC/DC
Colour
230/240 V AC
SL7-COMBINATION
2011955
Continuous light
Part no.
Article no.
SL7-L24-B
171461
SL7-L24-G
171462
SL7-L24-R
171463
SL7-L24-W
171464
SL7-L24-Y
171465
SL7-L24-A
171466
SL7-L230-B
171473
SL7-L230-G
171474
SL7-L230-R
171475
SL7-L230-W
171476
SL7-L230-Y
171477
SL7-L230-A
171426
Flashing light
2 Hz
Part no.
Article no.
SL7-BL24-B
171439
SL7-BL24-G
171440
SL7-BL24-R
171441
SL7-BL24-W
171442
SL7-BL24-Y
171388
SL7-BL24-A
171389
SL7-BL230-B
171396
SL7-BL230-G
171397
SL7-BL230-R
171398
SL7-BL230-W
171399
SL7-BL230-Y
171400
SL7-BL230-A
171401
SL4-COMBINATION
2011956
Strobe light
1.4 Hz
Part no.
Article no.
SL7-FL24-B
171402
SL7-FL24-G
171403
SL7-FL24-R
171404
SL7-FL24-W
171405
SL7-FL24-Y
171406
SL7-FL24-A
171407
SL7-FL230-B
171414
SL7-FL230-G
171415
SL7-FL230-R
171416
SL7-FL230-W
171417
SL7-FL230-Y
171418
SL7-FL230-A
171419
Notes 1) 110/120 V AC → Online Catalog
EATON CORPORATION CA08103003Z-EN 117
CA08103003Z_MOEM2015-EN.book Seite 116 Donnerstag, 7. April 2016 12:02 12
Signal towers SL7, SL4
System overview
5
6
6
5
5
1
3
2
4
8
8
Moeller® series
6
6
6
6
6
6 6
6
7
1
3
2
4
System overview
Card for filament lamp, continuous light
Module with LED/high power LED, continuous light
Card with LED, flashing light
Module with LED/high power LED, strobe light
116 EATON CORPORATION CA08103003Z-EN
8
7
6
8
5 Acoustic module
Base module
Base module with SWD connection
Accessory consideration
8
CA08103003Z_MOEM2015-EN.book Seite 117 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Complete devices, Light modules
Rated operational voltage
U e
V
Number of modules
IP66 complete units
Continuous light, LED, IP66, Base module with foot and 100 mm tube
24 V AC/DC 2
Colour
3
Module width
70 mm
Part no.
Article no.
Signal towers
Complete devices, Light modules
Module width
40 mm
Part no.
Article no.
SL7-100-L-RG-24LED
171424
SL7-100-L-RYG-24LED
171425
SL4-100-L-RG-24LED
171295
SL4-100-L-RYG-24LED
171296
Customised complete unit
Order on request
-
Rated operational voltage 1)
U e
V
Module with LED, IP66
24 V AC/DC
Colour
230/240 V AC
SL7-COMBINATION
2011955
Continuous light
Part no.
Article no.
SL7-L24-B
171461
SL7-L24-G
171462
SL7-L24-R
171463
SL7-L24-W
171464
SL7-L24-Y
171465
SL7-L24-A
171466
SL7-L230-B
171473
SL7-L230-G
171474
SL7-L230-R
171475
SL7-L230-W
171476
SL7-L230-Y
171477
SL7-L230-A
171426
Flashing light
2 Hz
Part no.
Article no.
SL7-BL24-B
171439
SL7-BL24-G
171440
SL7-BL24-R
171441
SL7-BL24-W
171442
SL7-BL24-Y
171388
SL7-BL24-A
171389
SL7-BL230-B
171396
SL7-BL230-G
171397
SL7-BL230-R
171398
SL7-BL230-W
171399
SL7-BL230-Y
171400
SL7-BL230-A
171401
SL4-COMBINATION
2011956
Strobe light
1.4 Hz
Part no.
Article no.
SL7-FL24-B
171402
SL7-FL24-G
171403
SL7-FL24-R
171404
SL7-FL24-W
171405
SL7-FL24-Y
171406
SL7-FL24-A
171407
SL7-FL230-B
171414
SL7-FL230-G
171415
SL7-FL230-R
171416
SL7-FL230-W
171417
SL7-FL230-Y
171418
SL7-FL230-A
171419
Notes 1) 110/120 V AC → Online Catalog
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 118 Donnerstag, 7. April 2016 12:02 12
Signal towers
Light modules
Light modules
Rated operational voltage 1)
U e
V
Card with high power LED, IP66
24 V AC/DC
Colour
Continuous light
Part no.
Article no.
Flashing light
2 Hz
Part no.
Article no.
Strobe light
1.4 Hz
Part no.
Article no.
Module with LED, IP66
24 V AC/DC
230/240 V AC
Moeller® series
Multistrobe light
1 - 2.6 Hz
Part no.
Article no.
-
-
-
-
-
-
SL4-BL24-B
171337
SL4-BL24-G
171338
SL4-BL24-R
171339
SL4-BL24-W
171340
SL4-BL24-Y
171341
SL4-BL24-A
171342
SL4-BL230-B
171349
SL4-BL230-G
171350
SL4-BL230-R
171351
SL4-BL230-W
171352
SL4-BL230-Y
171353
SL4-BL230-A
171354
SL7-L24-B-HP
171427
SL7-L24-G-HP
171428
SL7-L24-R-HP
171429
SL7-L24-W-HP
171430
SL7-L24-Y-HP
171431
SL7-L24-A-HP
171432
SL4-L24-B
171313
SL4-L24-G
171314
SL4-L24-R
171315
SL4-L24-W
171316
SL4-L24-Y
171317
SL4-L24-A
171318
SL4-L230-B
171325
SL4-L230-G
171326
SL4-L230-R
171327
SL4-L230-W
171328
SL4-L230-Y
171329
SL4-L230-A
171330
SL7-FL24-B-HP
171420
SL7-FL24-G-HP
171421
SL7-FL24-R-HP
171422
SL7-FL24-W-HP
171423
SL7-FL24-Y-HP
171273
SL7-FL24-A-HP
171274
SL4-FL24-B
171355
SL4-FL24-G
171356
SL4-FL24-R
171357
SL4-FL24-W
171358
SL4-FL24-Y
171359
SL4-FL24-A
171360
SL4-FL230-B
171367
SL4-FL230-G
171368
SL4-FL230-R
171369
SL4-FL230-W
171370
SL4-FL230-Y
171371
SL4-FL230-A
171372
SL7-FL24-B-HPM
171275
SL7-FL24-G-HPM
171276
SL7-FL24-R-HPM
171277
SL7-FL24-W-HPM
171278
SL7-FL24-Y-HPM
171279
SL7-FL24-A-HPM
171280
-
-
-
-
-
-
SL4-FL24-B-M
171373
SL4-FL24-G-M
171374
SL4-FL24-R-M
171375
SL4-FL24-W-M
171376
SL4-FL24-Y-M
171377
SL4-FL24-A-M
171378
Notes 1) 110/120 V AC → Online Catalog
Continuous light
Filament lamp max. 7 W
Part no.
Article no.
Continuous light
Filament lamp max. 4 W
Part no.
Article no.
Rated operational voltage
U e
V
Card for filament lamp, IP66
Without light elements, Filament bulbs → Accessories
< 250 V AC/DC
Colour
EATON CA08103003Z-EN-INT
SL7-L-B
171433
SL7-L-G
171434
SL7-L-R
171435
SL7-L-W
171436
SL7-L-Y
171437
SL7-L-A
171438
SL4-L-B
171331
SL4-L-G
171332
SL4-L-R
171333
SL4-L-W
171334
SL4-L-Y
171335
SL4-L-A
171336
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 119 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Acoustic modules, Basic modules
Description Rated operational voltage 1)
U e
V
Acoustic modules, IP66
Place only at the highest position on a pole
Continuous tone or pulsed tone, adjustable with internal dip switches.
Sound pressure 100 db, adjustable with internal potentiometer.
f = 2800 Hz
Continuous tone or pulsed tone, external actuation. Assigned two inputs (2 modules).
Sound pressure 100 db, adjustable with internal potentiometer.
f = 2800 Hz
Multi-tone; 8 tones, adjustable with internal dip switch.
Sound pressure 100 db, adjustable with internal potentiometer.
f = 500 - 2700 Hz
Continuous tone or pulsed tone, adjustable with internal dip switches.
Sound pressure 80 dB.
f = 4000 Hz
24 V AC/DC
230/240 V AC
24 V AC/DC
230/240 V AC
24 V AC/DC
230/240 V AC
24 V AC/DC
230/240 V AC
Rated operational current
I e mA
Colour max. 92 max. 43 max. 92 max. 43 max. 115 max. 43 max. 39 max. 21
Notes 1) 110/120 V AC → Online Catalog
Signal towers
Acoustic modules, Basic modules
Sound type Part no.
Article no.
SL7-AP24
171281
SL7-AP230
171283
SL7-AP24-E
171284
SL7-AP230-E
171286
SL7-AP24-M
171287
SL7-AP230-M
171289
SL4-AP24
171379
SL4-AP230
171381
Description
Basic modules
For horizontal mounting
Including cover
Max. 5 modules
Base with aluminium tube and plastic foot
Tube length
100 mm
250 mm
400 mm
800 mm
For use with
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
Base with aluminum tube and banjo bolt 100 mm
250 mm
400 mm
800 mm
Part no.
Article no.
For use with Part no.
Article no.
Spring-loaded terminals
SL7-CB-100
171443
SL7-CB-250
171444
SL7-CB-400
171445
SL7-CB-800
177312
SL7-CB-T-100
171452
SL7-CB-T-250
171453
SL7-CB-T-400
171454
SL7-CB-T-800
178460
SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
Push in terminals
SL4-PIB-100
171297
SL4-PIB-250
171298
SL4-PIB-400
171299
SL4-PIB-800
177313
SL4-PIB-T-100
171305
SL4-PIB-T-250
171306
SL4-PIB-T-400
171307
SL4-PIB-T-800
178461
EATON CORPORATION CA08103003Z-EN 119
CA08103003Z_MOEM2015-EN.book Seite 118 Donnerstag, 7. April 2016 12:02 12
Signal towers
Light modules
Light modules
Rated operational voltage 1)
U e
V
Card with high power LED, IP66
24 V AC/DC
Colour
Continuous light
Part no.
Article no.
Flashing light
2 Hz
Part no.
Article no.
Strobe light
1.4 Hz
Part no.
Article no.
Module with LED, IP66
24 V AC/DC
230/240 V AC
Moeller® series
Multistrobe light
1 - 2.6 Hz
Part no.
Article no.
-
-
-
-
-
-
SL4-BL24-B
171337
SL4-BL24-G
171338
SL4-BL24-R
171339
SL4-BL24-W
171340
SL4-BL24-Y
171341
SL4-BL24-A
171342
SL4-BL230-B
171349
SL4-BL230-G
171350
SL4-BL230-R
171351
SL4-BL230-W
171352
SL4-BL230-Y
171353
SL4-BL230-A
171354
SL7-L24-B-HP
171427
SL7-L24-G-HP
171428
SL7-L24-R-HP
171429
SL7-L24-W-HP
171430
SL7-L24-Y-HP
171431
SL7-L24-A-HP
171432
SL4-L24-B
171313
SL4-L24-G
171314
SL4-L24-R
171315
SL4-L24-W
171316
SL4-L24-Y
171317
SL4-L24-A
171318
SL4-L230-B
171325
SL4-L230-G
171326
SL4-L230-R
171327
SL4-L230-W
171328
SL4-L230-Y
171329
SL4-L230-A
171330
SL7-FL24-B-HP
171420
SL7-FL24-G-HP
171421
SL7-FL24-R-HP
171422
SL7-FL24-W-HP
171423
SL7-FL24-Y-HP
171273
SL7-FL24-A-HP
171274
SL4-FL24-B
171355
SL4-FL24-G
171356
SL4-FL24-R
171357
SL4-FL24-W
171358
SL4-FL24-Y
171359
SL4-FL24-A
171360
SL4-FL230-B
171367
SL4-FL230-G
171368
SL4-FL230-R
171369
SL4-FL230-W
171370
SL4-FL230-Y
171371
SL4-FL230-A
171372
SL7-FL24-B-HPM
171275
SL7-FL24-G-HPM
171276
SL7-FL24-R-HPM
171277
SL7-FL24-W-HPM
171278
SL7-FL24-Y-HPM
171279
SL7-FL24-A-HPM
171280
-
-
-
-
-
-
SL4-FL24-B-M
171373
SL4-FL24-G-M
171374
SL4-FL24-R-M
171375
SL4-FL24-W-M
171376
SL4-FL24-Y-M
171377
SL4-FL24-A-M
171378
Notes 1) 110/120 V AC → Online Catalog
Continuous light
Filament lamp max. 7 W
Part no.
Article no.
Continuous light
Filament lamp max. 4 W
Part no.
Article no.
Rated operational voltage
U e
V
Card for filament lamp, IP66
Without light elements, Filament bulbs → Accessories
< 250 V AC/DC
Colour
SL7-L-B
171433
SL7-L-G
171434
SL7-L-R
171435
SL7-L-W
171436
SL7-L-Y
171437
SL7-L-A
171438
SL4-L-B
171331
SL4-L-G
171332
SL4-L-R
171333
SL4-L-W
171334
SL4-L-Y
171335
SL4-L-A
171336
118 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 119 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Acoustic modules, Basic modules
Description Rated operational voltage 1)
U e
V
Acoustic modules, IP66
Place only at the highest position on a pole
Continuous tone or pulsed tone, adjustable with internal dip switches.
Sound pressure 100 db, adjustable with internal potentiometer.
f = 2800 Hz
Continuous tone or pulsed tone, external actuation. Assigned two inputs (2 modules).
Sound pressure 100 db, adjustable with internal potentiometer.
f = 2800 Hz
Multi-tone; 8 tones, adjustable with internal dip switch.
Sound pressure 100 db, adjustable with internal potentiometer.
f = 500 - 2700 Hz
Continuous tone or pulsed tone, adjustable with internal dip switches.
Sound pressure 80 dB.
f = 4000 Hz
24 V AC/DC
230/240 V AC
24 V AC/DC
230/240 V AC
24 V AC/DC
230/240 V AC
24 V AC/DC
230/240 V AC
I
Rated operational current e mA
Colour max. 92 max. 43 max. 92 max. 43 max. 115 max. 43 max. 39 max. 21
Notes 1) 110/120 V AC → Online Catalog
Signal towers
Acoustic modules, Basic modules
Sound type Part no.
Article no.
SL7-AP24
171281
SL7-AP230
171283
SL7-AP24-E
171284
SL7-AP230-E
171286
SL7-AP24-M
171287
SL7-AP230-M
171289
SL4-AP24
171379
SL4-AP230
171381
Description
Basic modules
For horizontal mounting
Including cover
Max. 5 modules
Base with aluminium tube and plastic foot
Tube length
100 mm
250 mm
400 mm
800 mm
For use with
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
Base with aluminum tube and banjo bolt 100 mm
250 mm
400 mm
800 mm
Part no.
Article no.
For use with Part no.
Article no.
Spring-loaded terminals
SL7-CB-100
171443
SL7-CB-250
171444
SL7-CB-400
171445
SL7-CB-800
177312
SL7-CB-T-100
171452
SL7-CB-T-250
171453
SL7-CB-T-400
171454
SL7-CB-T-800
178460
SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
Push in terminals
SL4-PIB-100
171297
SL4-PIB-250
171298
SL4-PIB-400
171299
SL4-PIB-800
177313
SL4-PIB-T-100
171305
SL4-PIB-T-250
171306
SL4-PIB-T-400
171307
SL4-PIB-T-800
178461
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 120 Donnerstag, 7. April 2016 12:02 12
Signal towers
Basic modules
Basic modules
Description
Basic modules
For horizontal mounting
Including cover
Max. 5 modules
Base with internal (on the inside) fixing holes -
Tube length For use with
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
Base with built-in (pre-assembled) fixing screws
-
Part no.
Article no.
For use with
Moeller® series
Part no.
Article no.
Spring-loaded terminals
SL7-CB-IMH
171447
SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
SL7-CB-IMS
171448
Push in terminals
SL4-PIB-IMH
171300
SL4-PIB-IMS
171301
Base with external fixing holes -
Base: Can hold tubes with a diameter of 25 mm
(±0.5)
-
SL7-CB-EMH
171449
SL7-CB-TM
179987
SL4-PIB-EMH
171302
SL4-PIB-TM
179986
Base with base adapter for slipping onto place
(rapid mounting and wiring system)
100 mm
250 mm
400 mm
800 mm
Base with base adapter for slipping onto place
(rapid mounting and wiring system)
Max. 0.3 A per module
External power supply connectable (24 V DC)
Configurable with SWD ‐ Assist (planning and ordering help)
For vertical mounting
Including cover
One-sided base with bracket
Max. 5 modules
100 mm
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
For vertical mounting on both sides
Including cover
Base with external fixing holes
Max. 2 x 5 modules
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
For vertical mounting on one sides
Including cover
Base with external fixing holes
Max. 3 modules
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
Screw terminals
SL7-FMS-100
171456
SL7-FMS-250
171457
SL7-FMS-400
171458
SL7-FMS-800
178462
Blade terminal
SWD4-8MF2
SL7-SWD
171459
Spring-loaded terminals
SL7-CB-FW
171450
SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
Spring-loaded terminals
SL7-CB-D
171451
SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
M12 plug, 4 pole
SL7-CB-D-M12A4
177351
Screw terminals
SL4-FMS-100
171308
SL4-FMS-250
171309
SL4-FMS-400
171310
SL4-FMS-800
178463
Blade terminal
SWD4-8MF2
SL4-SWD
171311
Push in terminals
SL4-PIB-FW
171303
Push in terminals
SL4-PIB-D
171304
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 121 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Accessories
Lifespan h
Magnetic base including M20 cable gland
For vertical mounting, Metal and plastic
-
Rated operational voltage Power
U e
V
-
Mounting brackets
For vertical mounting, Plastic
-
Including mounting bracket M20 cable gland
For vertical mounting, Metal
-
Tool for replacing filament lamp
-
-
-
-
-
For use with
Signal towers
Accessories
Part no.
Article no.
SL4-PIB-100(250)(400)
SL7-CB-100(250)(400)
SL7/4-MMS
172954
SL4-PIB-100(250)(400)
SL4-FMS…
SL7/4-FW
171446
-
SL4-PIB-T…
SL7-CB-T...
SL7/4-FW-T
171455
SL7/4-BET
171294
Filament bulbs
Mounting: Ba15d
> 3000 SL7-L-…
> 3000 12 V
24 V
120 V
230 V
12 V
24 V
120 V
230 V
5 W
6.5 W
7 W
6.5 W
4 W SL4-L-…
SL7-L12
171290
SL7-L24
171291
SL7-L120
171292
SL7-L230
171293
SL4-L12
171382
SL4-L24
171383
SL4-L120
171384
SL4-L230
171385
EATON CORPORATION CA08103003Z-EN 121
CA08103003Z_MOEM2015-EN.book Seite 120 Donnerstag, 7. April 2016 12:02 12
Signal towers
Basic modules
Basic modules
Description
Basic modules
For horizontal mounting
Including cover
Max. 5 modules
Base with internal (on the inside) fixing holes -
Tube length For use with
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
Base with built-in (pre-assembled) fixing screws
-
Part no.
Article no.
For use with
Moeller® series
Part no.
Article no.
Spring-loaded terminals
SL7-CB-IMH
171447
SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
SL7-CB-IMS
171448
Push in terminals
SL4-PIB-IMH
171300
SL4-PIB-IMS
171301
Base with external fixing holes -
Base: Can hold tubes with a diameter of 25 mm
(±0.5)
-
SL7-CB-EMH
171449
SL7-CB-TM
179987
SL4-PIB-EMH
171302
SL4-PIB-TM
179986
Base with base adapter for slipping onto place
(rapid mounting and wiring system)
100 mm
250 mm
400 mm
800 mm
Base with base adapter for slipping onto place
(rapid mounting and wiring system)
Max. 0.3 A per module
External power supply connectable (24 V DC)
Configurable with SWD ‐ Assist (planning and ordering help)
For vertical mounting
Including cover
One-sided base with bracket
Max. 5 modules
100 mm
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
For vertical mounting on both sides
Including cover
Base with external fixing holes
Max. 2 x 5 modules
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
For vertical mounting on one sides
Including cover
Base with external fixing holes
Max. 3 modules
SL7-L-…
SL7-BL-…
SL7-FL-…
SL7-AP-…
Screw terminals
SL7-FMS-100
171456
SL7-FMS-250
171457
SL7-FMS-400
171458
SL7-FMS-800
178462
Blade terminal
SWD4-8MF2
SL7-SWD
171459
Spring-loaded terminals
SL7-CB-FW
171450
SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
Spring-loaded terminals
SL7-CB-D
171451
SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
M12 plug, 4 pole
SL7-CB-D-M12A4
177351
Screw terminals
SL4-FMS-100
171308
SL4-FMS-250
171309
SL4-FMS-400
171310
SL4-FMS-800
178463
Blade terminal
SWD4-8MF2
SL4-SWD
171311
Push in terminals
SL4-PIB-FW
171303
Push in terminals
SL4-PIB-D
171304
120 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 121 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Accessories
Lifespan h
Magnetic base including M20 cable gland
For vertical mounting, Metal and plastic
-
Rated operational voltage Power
U e
V
-
Mounting brackets
For vertical mounting, Plastic
-
Including mounting bracket M20 cable gland
For vertical mounting, Metal
-
Tool for replacing filament lamp
-
-
-
-
-
For use with
Signal towers
Accessories
Part no.
Article no.
SL4-PIB-100(250)(400)
SL7-CB-100(250)(400)
SL7/4-MMS
172954
SL4-PIB-100(250)(400)
SL4-FMS…
SL7/4-FW
171446
-
SL4-PIB-T…
SL7-CB-T...
SL7/4-FW-T
171455
SL7/4-BET
171294
Filament bulbs
Mounting: Ba15d
> 3000 SL7-L-…
> 3000 12 V
24 V
120 V
230 V
12 V
24 V
120 V
230 V
5 W
6.5 W
7 W
6.5 W
4 W SL4-L-…
SL7-L12
171290
SL7-L24
171291
SL7-L120
171292
SL7-L230
171293
SL4-L12
171382
SL4-L24
171383
SL4-L120
171384
SL4-L230
171385
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Movements safely under control detect positions mechanically, optically and inductively
Wherever exact positioning is required, safety/position switches from
Eaton with positively opening contacts are used. They are equipped with
Cage Clamp or screw terminals and are available with metal and insulated enclosures. Their large connection area ensures that they can be wired quickly. Easy to fit and flexible operating heads are a further feature.
Safety-door switches and safety position switches protect persons and processes. They are used to ensure that protective doors are safely locked and ensure a safe shutdown.
Catalog download: www.eaton.eu/catalog
www.eaton.eu/positionswitches
www.eaton.eu/sensors
122
A variety of sensors makes it possible to use inductive, capacitive, or photoelectric object detection as necessary. These sensors are available in AC and DC versions, as well as in various cubic and tubular designs that make it easy to adapt to any type of location. One of the main highlights of this range consists of the programmable iProx series, which can be easily configured for any application at hand. In fact, E59 iProx can be used to replace a wide variety of standard sensors, e.g., when a replacement is necessary due to servicing.
EATON CA08103003Z-EN-INT
30°
More than a mechanical switch LSE-Titan
• Variable, adjustable switching point
• Precisely defined and reproducible
• Quick and bounce-free PNP-switching outputs facilitate high operating frequency
• Analog voltage output for precise position control
• Certified by the TÜV Rheinland
• With variable switching point or analog output
Reliable machine protection with non-contacting safety switches
The non-contacting safety switches of the
RS-Titan model series from Eaton were specially developed for monitoring of protective coverings.
• Non-contacting: long lifespan, easy installation, high tolerance for doors and hinged flaps that do not close precisely, low maintenance
• High IP67, IP69K degree of protection: easy to clean, rugged, and reliable
• Symmetrical enclosure: easy mounting, low inventory levels
• 2 or 3 switching contacts: suitable for many applications
• Potential-free contacts: easy connection
• SILCL3, PLe: safe and reliable
• M12 plug or cable: quick and easy connection
Eaton sensors: versatile and reliable
Eaton inductive and photoelectric sensors are available in a variety of designs and versions and are characterized by their unmatched reliability.
• Rugged design
• Nine different inductive sensor series
• E59 AccuProx with analog output
• E56 Pancake with a nominal range of
100 mm
• Opposed mode, refracted-light and diffused mode light barriers and more
• Perfect Prox technology for unparalleled background suppression
• A large signal reserve prevents failures and downtimes and extends maintenance intervals
EATON CA08103003Z-EN-INT 123
CA08103003Z_MOEM2015-EN.book Seite 124 Donnerstag, 7. April 2016 12:02 12
Position switches
Safety position switches LS-Titan
1
1
EATON CA08103003Z-EN-INT
Moeller® series
1
1
2
180°
1 Basic device LS, LSM
2 Mounting clamp
3 Roller lever
4 Angled roller lever
5 Rotary lever
6 Roller plunger
Safety position switches LS-Titan
3
4
5
6
7
8
9
7 Adjustable roller lever
8 Rounded plunger, centre fixing
9 Roller plunger, centre fixing
10 Actuating rod
11 Spring-rod actuator
12 Actuating rod
10
11
12
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 125 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Safety position switches LS-Titan
Contacts
Positive opening safety function according to
IEC/EN 60947-5-1
N/O =
Normally open
N/C =
Normally closed
Contact travel
■ = Contact closed
□ = Contact open
Contact sequence
Housing
Position switches
Safety position switches LS-Titan
Cage Clamp 1)
Part no.
Article no.
Screw terminal
Part no.
Article no.
Basic device, expandable
Operating heads → Page 129
IP66, IP67 analog electronic position switches
Visual status indication
Q1 = analog output
Q2 = diagnostics output
10
U [V]
0 100
S [%]
Insulated material
LSE-AU
274096
IP66, IP67 operating point electronically adjustable
Visual status indication, comparable with positive opening function
Partly short-circuit proof, Restart after reset
1 N/O
Rounded plunger, IP66, IP67
Notes
-
1 NC
2 NC
Q1
0 0.5
Q2
0 default = 3.0
0.5
Q1
Q2 default = 3.0
5.5
6.1
5.5
6.1
Insulated material
Insulated material
LSE-11
266121
LSE-02
266122
-
-
-
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
2 N/O
2 N/O
2 N/O
2 N/O
2 N/O
-
-
-
-
-
2 NC
1 NC
1 NC
2 NC
2 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
11-12
0 3.0
21-22
Zw = 4.5 mm
3.0
6.1
NC
NC
11-12
21-22
0 2.0
4.0
Zw (11-12) = 3.3 mm
Zw (21-22) = 5.3 mm
4.3
13-14
21-22
0
Zw = 4.5 mm
3.0
6.1
NC
NC
6.1
NO
NC
13-14
21-22
0
1.0
Zw = 2,3 mm
3.0
15-16
0
27-28
2.1
Zw = 4.5 mm
3.0
15-16
0
27-28
2.1
ZW = 5.5 mm
4.0
0
21-22
13-14
21-22
13-14
0
1.6
Zw = 5.5 mm
3.0
4.3
13-14
23-24
2.1
6.1
NO
NC
6.1
NC
NO
6.1
NC
NO
6.1
6.1
NO
NO
13-14
23-24
0 2.1
2.1
6.1
NO
NO
13-14
0
23-24
1.3
6.1
NO
NO
Insulated material
Metal
Insulated material
Insulated material
Metal
Insulated material
Insulated material
Metal
Insulated material
Metal
Insulated material
Metal
Insulated material
Metal
Insulated material
Metal
Insulated material
LS-02
266107
LSM-02
266142
LS-02A
116702
LS-11
266109
LSM-11
266144
LS-11A
116704
LS-11D
266114
LSM-11D
266149
LS-11DA
292361
LSM-11DA
292363
LS-11S
266105
LSM-11S
266140
LS-20
266120
LSM-20
266155
LS-20A
292362
LSM-20A
100051
LS-20B
116706
LS-S02
106729
LS-S02A
116703
LS-S11
106783
LS-S11A
116705
LS-S11D
106791
LS-S11DA
106795
LS-S11S
106798
LS-S20
106808
LS-S20A
106810
1) Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany.
Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402
EATON CORPORATION CA08103003Z-EN 125
CA08103003Z_MOEM2015-EN.book Seite 124 Donnerstag, 7. April 2016 12:02 12
Position switches
Safety position switches LS-Titan
1
1
Moeller® series
1
1
2
180°
1 Basic device LS, LSM
2 Mounting clamp
3 Roller lever
4 Angled roller lever
5 Rotary lever
6 Roller plunger
Safety position switches LS-Titan
3
4
5
6
7
8
9
7 Adjustable roller lever
8 Rounded plunger, centre fixing
9 Roller plunger, centre fixing
10 Actuating rod
11 Spring-rod actuator
12 Actuating rod
10
11
12
124 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 125 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Safety position switches LS-Titan
Contacts
Positive opening safety function according to
IEC/EN 60947-5-1
N/O =
Normally open
N/C =
Normally closed
Contact travel
■ = Contact closed
□ = Contact open
Contact sequence
Housing
Position switches
Safety position switches LS-Titan
Cage Clamp 1)
Part no.
Article no.
Screw terminal
Part no.
Article no.
Basic device, expandable
Operating heads → Page 129
IP66, IP67 analog electronic position switches
Visual status indication
Q1 = analog output
Q2 = diagnostics output
10
U [V]
0 100
S [%]
Insulated material
LSE-AU
274096
IP66, IP67 operating point electronically adjustable
Visual status indication, comparable with positive opening function
Partly short-circuit proof, Restart after reset
1 N/O
Rounded plunger, IP66, IP67
Notes
-
1 NC
2 NC
Q1
0 0.5
Q2
0 default = 3.0
0.5
Q1
Q2 default = 3.0
5.5
6.1
5.5
6.1
Insulated material
Insulated material
LSE-11
266121
LSE-02
266122
-
-
-
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
2 N/O
2 N/O
2 N/O
2 N/O
2 N/O
-
-
-
-
-
2 NC
1 NC
1 NC
2 NC
2 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
11-12
0 3.0
21-22
Zw = 4.5 mm
3.0
6.1
NC
NC
11-12
21-22
0 2.0
4.0
Zw (11-12) = 3.3 mm
Zw (21-22) = 5.3 mm
4.3
13-14
21-22
0
Zw = 4.5 mm
3.0
6.1
NC
NC
6.1
NO
NC
13-14
21-22
0
1.0
Zw = 2,3 mm
3.0
15-16
0
27-28
2.1
Zw = 4.5 mm
3.0
6.1
NO
NC
6.1
NC
NO
15-16
0
27-28
2.1
ZW = 5.5 mm
4.0
0
21-22
13-14
21-22
13-14
13-14
0
23-24
1.6
Zw = 5.5 mm
3.0
4.3
2.1
6.1
NC
NO
6.1
6.1
NO
NO
13-14
23-24
0 2.1
2.1
6.1
NO
NO
13-14
0
23-24
1.3
6.1
NO
NO
Insulated material
Metal
Insulated material
Insulated material
Metal
Insulated material
Insulated material
Metal
Insulated material
Metal
Insulated material
Metal
Insulated material
Metal
Insulated material
Metal
Insulated material
LS-02
266107
LSM-02
266142
LS-02A
116702
LS-11
266109
LSM-11
266144
LS-11A
116704
LS-11D
266114
LSM-11D
266149
LS-11DA
292361
LSM-11DA
292363
LS-11S
266105
LSM-11S
266140
LS-20
266120
LSM-20
266155
LS-20A
292362
LSM-20A
100051
LS-20B
116706
LS-S02
106729
LS-S02A
116703
LS-S11
106783
LS-S11A
116705
LS-S11D
106791
LS-S11DA
106795
LS-S11S
106798
LS-S20
106808
LS-S20A
106810
1) Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany.
Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 126 Donnerstag, 7. April 2016 12:02 12
Position switches
Safety position switches LS-Titan Moeller® series
Contacts
Positive opening safety function according to IEC/EN 60947-5-1
N/O = Normally open N/C = Normally closed
Housing
Complete devices
Roller plungers, IP66, IP67
1 N/O
1 N/O
1 N/O
1 NC
1 NC
1 NC
1 N/O
Spring-rod actuator IP66, IP67
1 NC
Not to be used as a safety position switch
1 N/O 1 NC
1 N/O 1 NC material
Metal material
Metal material
Metal
Snap-action contact
Connection type 1)
Part no.
Article no.
Screw terminal
Part no.
Article no.
-
-
Yes
Yes
Yes
Yes
LS-11/P
LSM-11/P
LS-11S/P
LSM-11S/P
266112
266147
266118
266153
LS-11S/S
LSM-11S/S
266104
266139
LS-S11/P
LS-S11S/P
106788
106801
LS-S11S/S 106805
Roller lever IP66, IP67
Long
-
-
1 N/O
1 N/O
1 N/O
1 N/O
Short
1 N/O
1 N/O
Large
1 N/O
Rotary lever, IP66, IP67
1 N/O
1 N/O
1 N/O
1 N/O
Adjustable roller levers, IP66, IP67
1 N/O
1 N/O
1 N/O
1 N/O
1 NC
1 NC
1 NC
1 NC
1 NC
2 NC
2 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
IP66, IP67 actuating rod
1 N/O
1 N/O
1 NC
1 NC
material
Metal material
Metal material
Metal material material material
Metal material
Metal
-
-
-
Yes
Yes
-
-
-
-
-
-
Yes
Yes material
Metal material
Metal
-
-
Yes
Yes material
Metal
Yes
Yes
LS-02/L
LSM-02/L
LS-11/L
LSM-11/L
LS-11S/L
LSM-11S/L
LS-11/LS
LS-11D/LS
LS-11/LB 290175
LS-11/RL
LSM-11/RL
LS-11S/RL
266111
266146
266117
LSM-11S/RL 266152
266108
266143
266110
266145
266116
266151
290173
290174
LS-S02/L
LS-S11/L
LS-S11S/L
106781
106785
106800
LS-S11/LS 106787
LS-S11D/LS 106794
LS-S11/LB 106786
LS-S11/RL 106789
LS-S11S/RL 106802
LS-11/RLA 266113
LSM-11/RLA 266148
LS-11S/RLA 266119
LSM-11S/RLA 266154
LS-S11/RLA 106790
LS-S11S/RLA 106803
LS-11S/RR 266106
LSM-11S/RR 266141
LS-S11S/RR 106804
Notes 1) Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany.
Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 127 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Position switches
Safety position switches LS-Titan
Basic device, expandable
-40 - +70, IP65, Insulated material
Rounded plunger -
Contacts
= safety function, by positive opening to IEC/EN 60947-5-1
N/O = Normally open N/C = Normally closed
Snap-action contact
2 NC -
-
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
2 N/O
2 N/O
2 N/O -
-
-
2 NC
1 NC
1 NC
1 NC
1 NC
1 NC
-
-
-
-
-
-
-
-
-
Contact travel
■ = Contact closed
□ = Contact open
Contact diagram
11-12
0 3.0
21-22
Zw = 4.5 mm
3.0
11-12
21-22
0 2.0
4.0
Zw (11-12) = 3.3 mm
Zw (21-22) = 5.3 mm
4.3
13-14
0
21-22
Zw = 4.5 mm
3.0
13-14
0
21-22
1.0
Zw = 2,3 mm
3.0
0
15-16
27-28
2.1
Zw = 4.5 mm
3.0
15-16
0
27-28
2.1
ZW = 5.5 mm
4.0
0
21-22
13-14
21-22
13-14
1.6
Zw = 5.5 mm
3.0
13-14
23-24
0 4.3
2.1
13-14
23-24
0 2.1
2.1
6.1
NC
NC
6.1
NC
NC
6.1
NO
NC
6.1
NO
NC
6.1
NC
NO
6.1
NC
NO
6.1
6.1
NO
NO
6.1
NO
NO
13-14
23-24
0 1.3
6.1
NO
NO
Cage Clamp 1)
Part no.
Article no.
Screwed terminal
Part no.
Article no.
LS-02-CC
LS-20-CC
176880 LS-S02-CC 176890
LS-02A-CC 176886 LS-S02A-CC 176895
LS-11-CC 176879 LS-S11-CC 176889
LS-11A-CC 176887 LS-S11A-CC 176896
LS-11D-CC 176882 LS-S11D-CC 176891
LS-11DA-CC 176884 LS-S11DA-CC 176893
LS-11S-CC 176881 LS-S11S-CC 144118
176883 LS-S20-CC 176892
LS-20A-CC 176885 LS-S20A-CC 176894
LS-20B-CC 176888 LS-S20B-CC 176897
Basic device, expandable
With M12 connector, IP66
Rounded plunger -
Notes
1 N/O
1 N/O
1 N/O
1 N/O
2 N/O
2 N/O
2 N/O -
-
-
2 NC
1 NC
1 NC
1 NC
1 NC
-
-
-
-
-
-
-
-
11-12
0 3.0
21-22
Zw = 4.5 mm
3.0
13-14
0
21-22
Zw = 4.5 mm
3.0
15-16
27-28
0
2.1
Zw = 4.5 mm
3.0
15-16
0
27-28
2.1
ZW = 5.5 mm
4.0
0
21-22
13-14
21-22
13-14
1.6
Zw = 5.5 mm
3.0
4.3
13-14
0
23-24
2.1
13-14
23-24
0 2.1
4.3
2.1
6.1
NC
NC
6.1
NO
NC
6.1
NC
NO
6.1
NC
NO
6.1
6.1
NO
NO
6.1
NO
NO
13-14
23-24
0 1.3
6.1
NO
NO
LS-02-M12A
LS-11-M12A
LS-11D-M12A
LS-11DA-
M12A
178131
LS-11S-M12A 178132
LS-20-M12A
LS-20A-M12A
LS-20B-M12A
178128
178129
178130
178133
178134
178135
1) Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany.
Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402
EATON CORPORATION CA08103003Z-EN 127
CA08103003Z_MOEM2015-EN.book Seite 126 Donnerstag, 7. April 2016 12:02 12
Position switches
Safety position switches LS-Titan Moeller® series
Contacts
Positive opening safety function according to IEC/EN 60947-5-1
N/O = Normally open N/C = Normally closed
Housing
Complete devices
Roller plungers, IP66, IP67
1 N/O
1 N/O
1 N/O
1 NC
1 NC
1 NC
1 N/O
Spring-rod actuator IP66, IP67
1 NC
Not to be used as a safety position switch
1 N/O 1 NC
1 N/O 1 NC material
Metal material
Metal material
Metal
Snap-action contact
Connection type 1)
Part no.
Article no.
Screw terminal
Part no.
Article no.
-
-
Yes
Yes
Yes
Yes
LS-11/P
LSM-11/P
LS-11S/P
LSM-11S/P
266112
266147
266118
266153
LS-11S/S
LSM-11S/S
266104
266139
LS-S11/P
LS-S11S/P
106788
106801
LS-S11S/S 106805
Roller lever IP66, IP67
Long
-
-
1 N/O
1 N/O
1 N/O
1 N/O
Short
1 N/O
1 N/O
Large
1 N/O
Rotary lever, IP66, IP67
1 N/O
1 N/O
1 N/O
1 N/O
Adjustable roller levers, IP66, IP67
1 N/O
1 N/O
1 N/O
1 N/O
1 NC
1 NC
1 NC
1 NC
1 NC
2 NC
2 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
IP66, IP67 actuating rod
1 N/O
1 N/O
1 NC
1 NC
material
Metal material
Metal material
Metal material material material
Metal material
Metal
-
-
-
Yes
Yes
-
-
-
-
-
-
Yes
Yes material
Metal material
Metal
-
-
Yes
Yes material
Metal
Yes
Yes
LS-02/L
LSM-02/L
LS-11/L
LSM-11/L
LS-11S/L
LSM-11S/L
LS-11/LS
LS-11D/LS
LS-11/LB 290175
LS-11/RL
LSM-11/RL
LS-11S/RL
266111
266146
266117
LSM-11S/RL 266152
266108
266143
266110
266145
266116
266151
290173
290174
LS-S02/L
LS-S11/L
LS-S11S/L
106781
106785
106800
LS-S11/LS 106787
LS-S11D/LS 106794
LS-S11/LB 106786
LS-S11/RL 106789
LS-S11S/RL 106802
LS-11/RLA 266113
LSM-11/RLA 266148
LS-11S/RLA 266119
LSM-11S/RLA 266154
LS-S11/RLA 106790
LS-S11S/RLA 106803
LS-11S/RR 266106
LSM-11S/RR 266141
LS-S11S/RR 106804
Notes
126
1) Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany.
Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402
EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 127 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Position switches
Safety position switches LS-Titan
Basic device, expandable
-40 - +70, IP65, Insulated material
Rounded plunger -
Contacts
= safety function, by positive opening to IEC/EN 60947-5-1
N/O = Normally open N/C = Normally closed
Snap-action contact
2 NC -
-
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
2 N/O
2 N/O
2 N/O -
-
-
2 NC
1 NC
1 NC
1 NC
1 NC
1 NC
-
-
-
-
-
-
-
-
-
Contact travel
■ = Contact closed
□ = Contact open
Contact diagram
11-12
0 3.0
21-22
Zw = 4.5 mm
3.0
11-12
21-22
0 2.0
4.0
Zw (11-12) = 3.3 mm
Zw (21-22) = 5.3 mm
4.3
13-14
0
21-22
Zw = 4.5 mm
3.0
13-14
0
21-22
1.0
Zw = 2,3 mm
3.0
0
15-16
27-28
2.1
Zw = 4.5 mm
3.0
15-16
0
27-28
2.1
ZW = 5.5 mm
4.0
0
21-22
13-14
21-22
13-14
1.6
Zw = 5.5 mm
3.0
13-14
23-24
0 4.3
2.1
13-14
23-24
0 2.1
2.1
6.1
NC
NC
6.1
NC
NC
6.1
NO
NC
6.1
NO
NC
6.1
NC
NO
6.1
NC
NO
6.1
6.1
NO
NO
6.1
NO
NO
13-14
23-24
0 1.3
6.1
NO
NO
Cage Clamp 1)
Part no.
Article no.
Screwed terminal
Part no.
Article no.
LS-02-CC
LS-20-CC
176880 LS-S02-CC 176890
LS-02A-CC 176886 LS-S02A-CC 176895
LS-11-CC 176879 LS-S11-CC 176889
LS-11A-CC 176887 LS-S11A-CC 176896
LS-11D-CC 176882 LS-S11D-CC 176891
LS-11DA-CC 176884 LS-S11DA-CC 176893
LS-11S-CC 176881 LS-S11S-CC 144118
176883 LS-S20-CC 176892
LS-20A-CC 176885 LS-S20A-CC 176894
LS-20B-CC 176888 LS-S20B-CC 176897
Basic device, expandable
With M12 connector, IP66
Rounded plunger -
1 N/O
1 N/O
1 N/O
1 N/O
2 N/O
2 N/O
2 N/O -
-
-
2 NC
1 NC
1 NC
1 NC
1 NC
-
-
-
-
-
-
-
-
11-12
0 3.0
21-22
Zw = 4.5 mm
3.0
13-14
0
21-22
Zw = 4.5 mm
3.0
15-16
27-28
0
2.1
Zw = 4.5 mm
3.0
15-16
0
27-28
2.1
ZW = 5.5 mm
4.0
0
21-22
13-14
21-22
13-14
1.6
Zw = 5.5 mm
3.0
4.3
13-14
0
23-24
2.1
13-14
23-24
0 2.1
4.3
2.1
6.1
NC
NC
6.1
NO
NC
6.1
NC
NO
6.1
NC
NO
6.1
6.1
NO
NO
6.1
NO
NO
13-14
23-24
0 1.3
6.1
NO
NO
LS-02-M12A
LS-11-M12A
LS-11D-M12A
LS-11DA-
M12A
178131
LS-11S-M12A 178132
LS-20-M12A
LS-20A-M12A
LS-20B-M12A
178128
178129
178130
178133
178134
178135
Notes 1) Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany.
Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 128 Donnerstag, 7. April 2016 12:02 12
Position switches
Safety position switches LS-Titan
Contacts
= safety function, by positive opening to IEC/EN 60947-5-1
N/O = Normally open
N/C = Normally closed
Snap-action contact
Contact travel
■ = Contact closed
□ = Contact open
Contact diagram
Complete device
With M12 connector, IP66
Roller plunger 1 N/O
1 N/O
Spring-rod actuator
Not to be used as a safety position switch
1 N/O
1 NC
1 NC
1 NC
-
Yes
Yes
13-14
21-22
0
Zw = 4.5 mm
3.0
0
21-22
13-14
21-22
13-14
1.6
Zw = 5.5 mm
3.0
13°
21-22
13-14
21-22
13-14
0°
7°
4.3
6.1
NO
NC
6.1
26°
Roller lever
Rotary lever
Adjustable roller lever
Actuating rod
Notes
Cage Clamp 1)
Part no.
LS-11/P-M12A
LS-11S/P-M12A
LS-11S/S-M12A
Moeller® series
Article no.
178137
178141
178145
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
-
-
-
Yes
Yes
Yes
Yes
Zw = 48˚
0˚
21-22
13-14
21-22
13-14
15˚
Zw = 60˚
0˚
21-22
13-14
21-22
13-14
15˚
Zw = 60˚
13-14
0
21-22
Zw = 7.1 mm
4.7
21-22
13-14
21-22
13-14
0
2.3
Zw = 8.7 mm
4.4
13-14
0˚
21-22
32˚
Zw = 48˚
0˚
21-22
13-14
21-22
13-14
15˚
Zw = 60˚
30˚
13-14
21-22
0˚
32˚
30˚
30˚
6.5
46˚
46˚
9.6
NO
NC
9.6
65˚
NO
NC
65˚
65˚
NO
NC
65˚
65˚
LS-11/L-M12A
LS-11S/L-M12A
LS-11/RL-M12A
LS-11S/RL-M12A
LS-11/RLA-M12A
LS-11S/RLA-M12A
LS-11S/RR-M12A
1) Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany.
Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402
178136
178140
178138
178142
178139
178143
178144
CA08103003Z_MOEM2015-EN.book Seite 129 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Operating heads
Insulated material
Part no.
Article no.
Roundet plunger, centre fixing
For mounting in enclosure wall or mounting plate drilling
M18 x 1
LS-XZS
114024
Metal
Part no.
Article no.
Roller plunger, centre fixing
For mounting in enclosure wall or mounting plate drilling
M18 x 1
LS-XZRS
114025
Roller plungers
-
Roller lever
Large
Short
Long
Angled roller lever
-
Rotary lever
-
Adjustable roller levers
⌀ 18 mm
⌀ 30 mm
⌀ 40 mm Roller: Rubber
⌀ 40 mm
Actuating rods
Bar: Insulated material
Bar: Metal
LS-XP
266125
LS-XLB
290178
LS-XLS
290177
LS-XL
266123
LS-XLA
266124
LS-XRL
266126
LS-XRLA
266127
LS-XRLA30
266128
LS-XRLA40R
266130
LS-XRLA40
266129
LS-XRR
266131
LS-XRRM
266132
LSM-XP
266158
LSM-XRR
266161
LSM-XRRM
266162
LSM-XL
266156
LSM-XLA
266157
LSM-XRL
266159
LSM-XRLA
266160
Notes
Position switches
Operating heads
The operating head can be rotated at 90° intervals to adapt to the specified approach direction.
Spring-rod
Not to be used as a safety position switch
Only permissible with snap-action contact
LS-XS
266133
LSM-XS
266163
Actuating rod
LS-XOR
290190
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 129
CA08103003Z_MOEM2015-EN.book Seite 128 Donnerstag, 7. April 2016 12:02 12
Position switches
Safety position switches LS-Titan
Contacts
= safety function, by positive opening to IEC/EN 60947-5-1
N/O = Normally open
N/C = Normally closed
Snap-action contact
Contact travel
■ = Contact closed
□ = Contact open
Contact diagram
Complete device
With M12 connector, IP66
Roller plunger 1 N/O
1 N/O
Spring-rod actuator
Not to be used as a safety position switch
1 N/O
1 NC
1 NC
1 NC
-
Yes
Yes
13-14
21-22
0
Zw = 4.5 mm
3.0
0
21-22
13-14
21-22
13-14
1.6
Zw = 5.5 mm
3.0
13°
21-22
13-14
21-22
13-14
0°
7°
4.3
6.1
NO
NC
6.1
26°
Roller lever
Rotary lever
Adjustable roller lever
Actuating rod
Notes
Cage Clamp 1)
Part no.
LS-11/P-M12A
LS-11S/P-M12A
LS-11S/S-M12A
Moeller® series
Article no.
178137
178141
178145
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 N/O
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
1 NC
-
-
-
Yes
Yes
Yes
Yes
Zw = 48˚
0˚
21-22
13-14
21-22
13-14
15˚
Zw = 60˚
0˚
21-22
13-14
21-22
13-14
15˚
Zw = 60˚
13-14
0
21-22
Zw = 7.1 mm
4.7
21-22
13-14
21-22
13-14
0
2.3
Zw = 8.7 mm
4.4
13-14
0˚
21-22
32˚
Zw = 48˚
0˚
21-22
13-14
21-22
13-14
15˚
Zw = 60˚
30˚
13-14
21-22
0˚
32˚
30˚
30˚
6.5
46˚
46˚
9.6
NO
NC
9.6
65˚
NO
NC
65˚
65˚
NO
NC
65˚
65˚
LS-11/L-M12A
LS-11S/L-M12A
LS-11/RL-M12A
LS-11S/RL-M12A
LS-11/RLA-M12A
LS-11S/RLA-M12A
LS-11S/RR-M12A
1) Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany.
Accessories for the Cage-Clamp terminals from Wago:power comb, gray, Wago Article No. 264-402
178136
178140
178138
178142
178139
178143
178144
CA08103003Z_MOEM2015-EN.book Seite 129 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Operating heads
Insulated material
Part no.
Article no.
Roundet plunger, centre fixing
For mounting in enclosure wall or mounting plate drilling
M18 x 1
LS-XZS
114024
Metal
Part no.
Article no.
Roller plunger, centre fixing
For mounting in enclosure wall or mounting plate drilling
M18 x 1
LS-XZRS
114025
Roller plungers
-
Roller lever
Large
Short
Long
Angled roller lever
-
Rotary lever
-
Adjustable roller levers
⌀ 18 mm
⌀ 30 mm
⌀ 40 mm Roller: Rubber
⌀ 40 mm
Actuating rods
Bar: Insulated material
Bar: Metal
LS-XP
266125
LS-XLB
290178
LS-XLS
290177
LS-XL
266123
LS-XLA
266124
LS-XRL
266126
LS-XRLA
266127
LS-XRLA30
266128
LS-XRLA40R
266130
LS-XRLA40
266129
LS-XRR
266131
LS-XRRM
266132
LSM-XP
266158
LSM-XRR
266161
LSM-XRRM
266162
LSM-XL
266156
LSM-XLA
266157
LSM-XRL
266159
LSM-XRLA
266160
Notes
Position switches
Operating heads
The operating head can be rotated at 90° intervals to adapt to the specified approach direction.
Spring-rod
Not to be used as a safety position switch
Only permissible with snap-action contact
LS-XS
266133
LSM-XS
266163
Actuating rod
LS-XOR
290190
128 EATON CORPORATION CA08103003Z-EN Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 130 Donnerstag, 7. April 2016 12:02 12
Position switches
Safety position swtich LS-ZBZ Moeller® series
1
7
6
5
5
4
3
1 Basic device
2 Flat flexible actuator
3 Angled flexible actuator
4 Flat actuator
5 Angled actuator
6 Flat compensating actuator
7 Angled compensating actuator
Order actuators separately → online catalog
2
Safety position swtich LS-ZBZ
Contacts
Positive opening safety function according to
IEC/EN 60947-5-1
N/O =
Normally open
N/C = Normally closed
Rated control voltage for magnetic drive
U s
V
Basic units with spring-powered interlock (closed-circuit principle) IP65
1 N/O 1 NC 24 V DC
2 NC 24 V DC
-
1 N/O
-
1 N/O
1 NC
2 NC
1 NC
2 NC
120 V 50/60 Hz
120 V 50/60 Hz
230 V 50/60 Hz
230 V 50/60 Hz
Part no.
Article no.
LS-S11-24DFT-ZBZ/X
106829
LS-S02-24DFT-ZBZ/X
106823
LS-S11-120AFT-ZBZ/X
106825
LS-S02-120AFT-ZBZ/X
106778
LS-S11-230AFT-ZBZ/X
106827
LS-S02-230AFT-ZBZ/X
106821
Notes
Switch must never be used as a mechanical stop!
The operating head can be rotated manually in 90° steps without tools to suit the specified level of actuation.
With the actuator inserted, the N/O contact is open and the N/C contact is closed.
For degree of protection IP65, use V-M20 (206910) cable glands with connecting thread of max. 9 mm length.
In the event of power failure (e.g., during commissioning), the device can be released with a screwdriver. The auxiliary release mechanism must be sealed! → Instructional lea et IL 05208005Z
Basic devices with magnet-powered interlock (open-circuit principle)
IP65
1 N/O 1 NC 24 V DC
-
-
1 N/O
-
1 N/O
2 NC
1 NC
2 NC
1 NC
2 NC
24 V DC
120 V 50/60 Hz
120 V 50/60 Hz
230 V 50/60 Hz
230 V 50/60 Hz
LS-S11-24DMT-ZBZ/X
106830
LS-S02-24DMT-ZBZ/X
106824
LS-S11-120AMT-ZBZ/X
106826
LS-S02-120AMT-ZBZ/X
106820
LS-S11-230AMT-ZBZ/X
106828
LS-S02-230AMT-ZBZ/X
106822
Switch must never be used as a mechanical stop!
The operating head can be rotated manually in 90° steps without tools to suit the specified level of actuation.
With the actuator inserted, the N/O contact is open and the N/C contact is closed.
For degree of protection IP65, use V-M20 (206910) cable glands with connecting thread of max. 9 mm length.
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 131 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Safety position switches
Contacts
Positive opening safety function according to
IEC/EN 60947-5-1
Approval
Safety door flap switch LSR-…/TKG. IP65
2 NC
1 N/O 1 NC
Connection type
Part no.
Article no.
Notes
Screw terminal
LSR-S02-1-I/TKG
106848
LSR-S11-1-I/TKG
106847
Position switches
Safety position switches
Hinge-operated safety switch LSR-…/TS, IP65
-
1 N/O
2 NC
1 NC
Screw terminal
LSR-S02-1-I/TS
106852
LSR-S11-1-I/TS
106851
Safety position switches LS…-ZB, IP65
2 NC
-
1 N/O
1 N/O
1 N/O
1 N/O
2 NC
1 NC
1 NC
1 NC
1 NC
Safety/ position switch LS4…/ZB, IP65
1 N/O 1 NC
1 N/O
1 N/O
1 NC
2 NC
Cage Clamp LS-02-ZB
106817
Screw terminal
LS-S02-ZB
106874
Cage Clamp LS-11-ZB
106819
Screw terminal
LS-S11-ZB
106876
Cage Clamp LS-11S-ZB
106870
Screw terminal
LS-S11S-ZB
106877
Screw terminal
LS4/S11-1/I/ZB
106857
LS4/S11-1/IA/ZB
106858
LS4/S12-7/IB/ZB
106859
Switch must never be used as a mechanical stop!
Actuator can be repositioned for horizontal or vertical mounting.
The operating heads can be turned manually in 90° steps to suit the specified level of actuation.
With the actuator inserted, the N/O contact is open and the
N/C contact is closed.
For degree of protection IP65, use V-M20 (206910) cable glands with connecting thread of max. 9 mm length.
Part no.
Article no.
Contacts
N/O = Normally open N/C = Normally closed
Non-contacting safety switch
IP67, IP69K
Reed contacts
Part no.
-
1 N/O
1 N/O
2 NC
1 NC
2 NC
Article no.
3 m connection cable
RS2-02-C3
RS2-11-C3
RS2-12-C3
177286
177287
177288
Plug-in connection M12 x 1
RS2-02-Q4
RS2-11-Q4
RS2-12-Q6
177289
177290
177291
-
1 N/O
1 N/O
-
1 N/O
-
1 N/O
1 N/O
1 N/O
2 NC
1 NC
2 NC
2 NC
1 NC
2 NC
2 NC
1 NC
2 NC
RS2R-02-C3
RS2R-11-C3
RS2R-12-C3
177292
177293
177294
10 m connection cable
RS2-02-C10
RS2-11-C10
RS2-12-C10
RS2R-02-C10
177300
177301
177302
177303
RS2R-11-C10
RS2R-12-C10
177304
177305
RS2R-02-Q4
RS2R-11-Q4
RS2R-12-Q6
EATON CORPORATION CA08103003Z-EN
177295
177296
177297
131
CA08103003Z_MOEM2015-EN.book Seite 130 Donnerstag, 7. April 2016 12:02 12
Position switches
Safety position swtich LS-ZBZ Moeller® series
1
7
6
5
5
4
3
1 Basic device
2 Flat flexible actuator
3 Angled flexible actuator
4 Flat actuator
5 Angled actuator
6 Flat compensating actuator
7 Angled compensating actuator
Order actuators separately → online catalog
2
Safety position swtich LS-ZBZ
Contacts
Positive opening safety function according to
IEC/EN 60947-5-1
N/O =
Normally open
N/C = Normally closed
Rated control voltage for magnetic drive
U s
V
Basic units with spring-powered interlock (closed-circuit principle) IP65
1 N/O 1 NC 24 V DC
2 NC 24 V DC
-
1 N/O
-
1 N/O
1 NC
2 NC
1 NC
2 NC
120 V 50/60 Hz
120 V 50/60 Hz
230 V 50/60 Hz
230 V 50/60 Hz
Part no.
Article no.
LS-S11-24DFT-ZBZ/X
106829
LS-S02-24DFT-ZBZ/X
106823
LS-S11-120AFT-ZBZ/X
106825
LS-S02-120AFT-ZBZ/X
106778
LS-S11-230AFT-ZBZ/X
106827
LS-S02-230AFT-ZBZ/X
106821
Notes
Switch must never be used as a mechanical stop!
The operating head can be rotated manually in 90° steps without tools to suit the specified level of actuation.
With the actuator inserted, the N/O contact is open and the N/C contact is closed.
For degree of protection IP65, use V-M20 (206910) cable glands with connecting thread of max. 9 mm length.
In the event of power failure (e.g., during commissioning), the device can be released with a screwdriver. The auxiliary release mechanism must be sealed! → Instructional lea et IL 05208005Z
Basic devices with magnet-powered interlock (open-circuit principle)
IP65
1 N/O 1 NC 24 V DC
-
-
1 N/O
-
1 N/O
2 NC
1 NC
2 NC
1 NC
2 NC
24 V DC
120 V 50/60 Hz
120 V 50/60 Hz
230 V 50/60 Hz
230 V 50/60 Hz
LS-S11-24DMT-ZBZ/X
106830
LS-S02-24DMT-ZBZ/X
106824
LS-S11-120AMT-ZBZ/X
106826
LS-S02-120AMT-ZBZ/X
106820
LS-S11-230AMT-ZBZ/X
106828
LS-S02-230AMT-ZBZ/X
106822
Switch must never be used as a mechanical stop!
The operating head can be rotated manually in 90° steps without tools to suit the specified level of actuation.
With the actuator inserted, the N/O contact is open and the N/C contact is closed.
For degree of protection IP65, use V-M20 (206910) cable glands with connecting thread of max. 9 mm length.
130 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 131 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Safety position switches
Contacts
Positive opening safety function according to
IEC/EN 60947-5-1
Approval
Safety door flap switch LSR-…/TKG. IP65
2 NC
1 N/O 1 NC
Connection type
Part no.
Article no.
Notes
Screw terminal
LSR-S02-1-I/TKG
106848
LSR-S11-1-I/TKG
106847
Position switches
Safety position switches
Hinge-operated safety switch LSR-…/TS, IP65
-
1 N/O
2 NC
1 NC
Screw terminal
LSR-S02-1-I/TS
106852
LSR-S11-1-I/TS
106851
Safety position switches LS…-ZB, IP65
2 NC
-
1 N/O
1 N/O
1 N/O
1 N/O
2 NC
1 NC
1 NC
1 NC
1 NC
Safety/ position switch LS4…/ZB, IP65
1 N/O 1 NC
1 N/O
1 N/O
1 NC
2 NC
Cage Clamp LS-02-ZB
106817
Screw terminal
LS-S02-ZB
106874
Cage Clamp LS-11-ZB
106819
Screw terminal
LS-S11-ZB
106876
Cage Clamp LS-11S-ZB
106870
Screw terminal
LS-S11S-ZB
106877
Screw terminal
LS4/S11-1/I/ZB
106857
LS4/S11-1/IA/ZB
106858
LS4/S12-7/IB/ZB
106859
Switch must never be used as a mechanical stop!
Actuator can be repositioned for horizontal or vertical mounting.
The operating heads can be turned manually in 90° steps to suit the specified level of actuation.
With the actuator inserted, the N/O contact is open and the
N/C contact is closed.
For degree of protection IP65, use V-M20 (206910) cable glands with connecting thread of max. 9 mm length.
Part no.
Article no.
Contacts
N/O = Normally open N/C = Normally closed
Non-contacting safety switch
IP67, IP69K
Reed contacts
Part no.
-
1 N/O
1 N/O
2 NC
1 NC
2 NC
Article no.
3 m connection cable
RS2-02-C3
RS2-11-C3
RS2-12-C3
177286
177287
177288
Plug-in connection M12 x 1
RS2-02-Q4
RS2-11-Q4
RS2-12-Q6
177289
177290
177291
-
1 N/O
1 N/O
2 NC
1 NC
2 NC
-
1 N/O
-
1 N/O
1 N/O
1 N/O
Complete assortment -> www.eaton.eu/ecat
2 NC
1 NC
2 NC
2 NC
1 NC
2 NC
RS2R-02-C3
RS2R-11-C3
RS2R-12-C3
177292
177293
177294
10 m connection cable
RS2-02-C10
RS2-11-C10
RS2-12-C10
RS2R-02-C10
177300
177301
177302
177303
RS2R-11-C10
RS2R-12-C10
177304
177305
EATON CA08103003Z-EN-INT
RS2R-02-Q4
RS2R-11-Q4
RS2R-12-Q6
177295
177296
177297
CA08103003Z_MOEM2015-EN.book Seite 132 Donnerstag, 7. April 2016 12:02 12
Sensors
Inductive Sensors
Inductive Sensors
Design (outer dimensions)
Rated switching distance
S n
mm mm
E52 Cube Series
2 LEDs for current and output status
Housing adapter, 4-wire, Plug-in connection M12 x 1,
Rated operational voltage U e
Switching type: NPN, PNP
Zinc/Insulated material
10 – 48 V DC
40 x 40 x 40
25
30
35
40
15
15
20
20
E56 Pancake Series
2 LEDs for current and output status
4-wire, Plug-in connection M12 x 1,
Rated operational voltage U e
Switching type: NPN, PNP
Insulated material
10 – 48 V DC
79 x 79 x 39
79 x 79 x 39
40
40
Type of mounting
Flush
Non-flush
Flush
Non-flush
Flush
Non-flush
Contacts
N/C = Normally closed
N/O = Normally open
Degree of
Protection
Part no.
1 NC
1 NC
1 N/O
1 N/O
IP67
IP67 E56ADL40SAD01
E56ADL40UAD01
Article no.
E52Q-DL15SAD01
E52Q-DL15UAD01
E52Q-DL20SAD01
E52Q-DL20UAD01
E52Q-DL25UAD01
E52Q-DL30UAD01
E52Q-DL35UAD01
E52Q-DL40UAD01
135804
135805
135806
135807
135808
135809
135810
135811
136234
136235
109 x 110 x 41 70
171.5 x 171.5 x 67.4
100
Non-flush
Non-flush
E56BDL70UAD01
E56CDL100UAD01
136236
136237
E57 Global Series
LED for output status
3-wire, Plug-in connection M12 x 1,
Rated operational voltage U e
Switching type: PNP
Metal
10 - 30 V DC
M8 x 1 1 N/O
M12 x 1
M18 x 1
M30 x 1.5
2
4
5
10
1
2
3
6
10
15
15
29
5
8
8
18
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Flush
Non-flush
Flush
Non-flush
Flush
Non-flush
Flush
Non-flush
Flush
Flush
Non-flush
Non-flush
Flush
Flush
Non-flush
Non-flush
IP67,
IP69K
E57-08GS01-GDB
E57-08GU02-GDB
E57-08GE03-GDB
E57-08GE06-GDB
E57-12GS02-GDB
E57-12GU04-GDB
E57-12GE05-GDB
E57-12GE10-GDB
E57-18GS05-GDB
E57-18GE08-GDB
E57-18GU08-GDB
E57-18GE18-GDB
E57-30GS10-GDB
E57-30GE15-GDB
E57-30GU15-GDB
E57-30GE29-GDB
135862
135866
135854
135858
135886
135895
135870
135878
135932
135915
135940
135924
135978
135960
135986
135968
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 133 Donnerstag, 7. April 2016 12:02 12
Sensors
Inductive and capacitive sensors
Design (outer dimensions)
mm
E57 miniature series (inductive)
3-wire, 2 m connection cable,
Rated operational voltage U e
10 - 30 V DC
Switching type: PNP
Stainless steel
M5 x 1
⌀ 4
⌀ 6,5
⌀ 6,5 iProx Series (inductive)
3-wire, Plug-in connection M12 x 1,
Rated operational voltage U e
6 - 48 V DC
Switching type: NPN, PNP
Stainless steel
M12 x 1
M18 x 1
M18 x 1
M30 x 1.5
4
8
18
15
1
2
0.8
0.8
Rated switching distance
S n mm
Type of mounting
Contacts
N/C = Normally closed
N/O = Normally open
Degree of
Protection
Part no.
Flush
Flush
Flush
Non-flush -
-
-
-
Flush
Flush
Non-flush
Flush
-
-
-
-
1 N/O
1 N/O
IP67
Article no.
E57EAL5T111SP
E57EAL4T111SP
E57EAL6T111SP
E57EAL6T111EP
136241
136239
136245
136244
IP67,
IP69K
E59-M12A105D01-D1 136207
E59-M18A108D01-D1 136215
E59-M18C116D01-D1 136219
E59-M30A115D01-D1 136223
Programming cable
For use with iProx
E59RP1 136229
Programming software
For use with iProx
-
4-wire
Plug-in connection M12 x 1
Rated operational voltage: U e
10 – 48 V DC
Switching type: NPN, PNP
Zinc/Insulated material
M18 x 1
M30 x 1.5
34 ⌀ 25
25
35
35
20
20
25
25
8
8
15
15
E59SW1 136230
Flush
Flush
Non-flush
Non-flush
-
-
1 NC
1 NC
-
1 N/O
-
1 N/O
IP65 E53KBL18T111SD
E53KAL18T111SD
E53KBL18T111ED
E53KAL18T111ED
134802
134768
134801
134767
Flush
Flush
Non-flush
Non-flush
Flush
Flush
Non-flush
Non-flush
-
1 NC
-
1 NC
-
1 NC
-
1 NC
-
-
-
-
1 N/O
1 N/O
1 N/O
1 N/O
EATON CORPORATION CA08103003Z-EN
E53KBL30T111SD
E53KAL30T111SD
E53KBL30T111ED
E53KAL30T111ED
E53KBL34T111SD
E53KAL34T111SD
E53KBL34T111ED
E53KAL34T111ED
134814
134780
134813
134779
134824
134790
134823
134789
133
CA08103003Z_MOEM2015-EN.book Seite 132 Donnerstag, 7. April 2016 12:02 12
Sensors
Inductive Sensors
Inductive Sensors
Design (outer dimensions)
Rated switching distance
S n
mm mm
E52 Cube Series
2 LEDs for current and output status
Housing adapter, 4-wire, Plug-in connection M12 x 1,
Rated operational voltage U e
Switching type: NPN, PNP
Zinc/Insulated material
10 – 48 V DC
40 x 40 x 40
25
30
35
40
15
15
20
20
E56 Pancake Series
2 LEDs for current and output status
4-wire, Plug-in connection M12 x 1,
Rated operational voltage U e
Switching type: NPN, PNP
Insulated material
10 – 48 V DC
79 x 79 x 39
79 x 79 x 39
40
40
Type of mounting
Flush
Non-flush
Flush
Non-flush
Flush
Non-flush
Contacts
N/C = Normally closed
N/O = Normally open
Degree of
Protection
Part no.
1 NC
1 NC
1 N/O
1 N/O
IP67
IP67
Article no.
E52Q-DL15SAD01
E52Q-DL15UAD01
E52Q-DL20SAD01
E52Q-DL20UAD01
E52Q-DL25UAD01
E52Q-DL30UAD01
E52Q-DL35UAD01
E52Q-DL40UAD01
135804
135805
135806
135807
135808
135809
135810
135811
E56ADL40SAD01
E56ADL40UAD01
136234
136235
109 x 110 x 41 70
171.5 x 171.5 x 67.4
100
Non-flush
Non-flush
E56BDL70UAD01
E56CDL100UAD01
136236
136237
E57 Global Series
LED for output status
3-wire, Plug-in connection M12 x 1,
Rated operational voltage U e
Switching type: PNP
Metal
10 - 30 V DC
M8 x 1 1 N/O
M12 x 1
M18 x 1
M30 x 1.5
2
4
5
10
1
2
3
6
10
15
15
29
5
8
8
18
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Flush
Non-flush
Flush
Non-flush
Flush
Non-flush
Flush
Non-flush
Flush
Flush
Non-flush
Non-flush
Flush
Flush
Non-flush
Non-flush
IP67,
IP69K
E57-08GS01-GDB
E57-08GU02-GDB
E57-08GE03-GDB
E57-08GE06-GDB
E57-12GS02-GDB
E57-12GU04-GDB
E57-12GE05-GDB
E57-12GE10-GDB
E57-18GS05-GDB
E57-18GE08-GDB
E57-18GU08-GDB
E57-18GE18-GDB
E57-30GS10-GDB
E57-30GE15-GDB
E57-30GU15-GDB
E57-30GE29-GDB
135862
135866
135854
135858
135886
135895
135870
135878
135932
135915
135940
135924
135978
135960
135986
135968
132 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 133 Donnerstag, 7. April 2016 12:02 12
Design (outer dimensions)
mm
E57 miniature series (inductive)
3-wire, 2 m connection cable,
Rated operational voltage U e
10 - 30 V DC
Switching type: PNP
Stainless steel
M5 x 1
⌀ 4
⌀ 6,5
⌀ 6,5 iProx Series (inductive)
3-wire, Plug-in connection M12 x 1,
Rated operational voltage U e
6 - 48 V DC
Switching type: NPN, PNP
Stainless steel
M12 x 1
M18 x 1
M18 x 1
M30 x 1.5
4
8
18
15
1
2
0.8
0.8
Sensors
Inductive and capacitive sensors
Article no.
Rated switching distance
S n mm
Type of mounting
Contacts
N/C = Normally closed
N/O = Normally open
Degree of
Protection
Part no.
Flush
Flush
Flush
Non-flush -
-
-
-
Flush
Flush
Non-flush
Flush
-
-
-
-
1 N/O
1 N/O
IP67 E57EAL5T111SP
E57EAL4T111SP
E57EAL6T111SP
E57EAL6T111EP
136241
136239
136245
136244
IP67,
IP69K
E59-M12A105D01-D1 136207
E59-M18A108D01-D1 136215
E59-M18C116D01-D1 136219
E59-M30A115D01-D1 136223
Programming cable
For use with iProx
E59RP1 136229
Programming software
For use with iProx
-
4-wire
Plug-in connection M12 x 1
Rated operational voltage: U e
10 – 48 V DC
Switching type: NPN, PNP
Zinc/Insulated material
M18 x 1
M30 x 1.5
34 ⌀
Complete assortment -> www.eaton.eu/ecat
25
25
35
35
20
20
25
25
8
8
15
15
E59SW1 136230
Flush
Flush
Non-flush
Non-flush
-
-
1 NC
1 NC
-
1 N/O
-
1 N/O
Flush
Flush
Non-flush
Non-flush
Flush
Flush
Non-flush
Non-flush
-
1 NC
-
1 NC
-
1 NC
-
1 NC
-
-
-
-
1 N/O
1 N/O
1 N/O
1 N/O
EATON CA08103003Z-EN-INT
IP65 E53KBL18T111SD
E53KAL18T111SD
E53KBL18T111ED
E53KAL18T111ED
134802
134768
134801
134767
E53KBL30T111SD
E53KAL30T111SD
E53KBL30T111ED
E53KAL30T111ED
E53KBL34T111SD
E53KAL34T111SD
E53KBL34T111ED
E53KAL34T111ED
134814
134780
134813
134779
134824
134790
134823
134789
CA08103003Z_MOEM2015-EN.book Seite 134 Donnerstag, 7. April 2016 12:02 12
Sensors
Optical sensors
Optical sensors
Function Description
Comet Series
4-wire,
Rated operational voltage U e
10 - 30 V DC
Switching type: NPN, PNP
Insulated material
Plug-in connection M12 x 1
Degree of Protection IP67
M18 x 1 Reflected-light beam
Beam: straight
With background suppression (Perfect Prox)
Can be expanded with fiber optic cable → Accessories
With background suppression (Perfect Prox)
Beam: straight
50
200
225
610
Rated switching distance
S n mm
Type of light
Switching principle
Part no.
Visible red
Infra-red
Adjustable bright/dark switching
13104AQD07
13106AQD07
13103AQD07
13100AQD07
Visible red
14102AQD07 Reflex photoelectric sensor
Thru-beam photoelectric sensor
E58 Harsh Duty Series
4-wire,
Rated operational voltage U e
10 - 30 V DC
Switching type: NPN, PNP
Stainless steel
Plug-in connection M12 x 1
Degree of Protection IP69K
M18 x 1 Reflected-light beam
Non-polarized
Beam: straight
With background suppression
(Perfect Prox)
7600
24000
24000
M30 x 1.5
M30 x 1.5
Reflex photoelectric sensor
Reflex photoelectric sensor
Thru-beam photoelectric sensor
For combination with reflector
E67 Long Range Series
4-wire,
Rated operational voltage U e
18 – 30 V DC
Switching type: NPN
Plug-in connection M12 x 1, PNP
Degree of Protection IP67
Rectangular
(166 x 59 x 43)
Reflected-light beam with background suppression
(Perfect Prox) with background suppression
(Perfect Prox)
18000
Source (for combination with detector)
Detector (for combination with source)
250000
250000
250000
1000
1000
100
280
280
50
50
100
18000
-
12102AQD07
11102AQD07
Article no.
135577
135565
Visible red
-
-
Visible red
Light switching
Dark switching
Light switching
Dark switching
Dark switching
Light switching
Dark switching
Light switching
-
Dark switching
Light switching
E58-18DP50-HLP
E58-18DP50-HDP
E58-18DP100-HLP
135673
135671
135667
E58-18DP100-HDP 135665
E58-30DPS280-HDP 135681
E58-30DPS280-HLP 135683
E58-30RS18-HDP 135689
E58-30RS18-HLP
E58-30TS250-HAP
E58-30TD250-HDP
E58-30TD250-HLP
135691
135697
135693
135695
Infra-red Light switching
Dark switching
E67-LRDP100-HLD
E67-LRDP100-HDD
100548
100547
135605
135621
135597
135581
135657
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 135 Donnerstag, 7. April 2016 12:02 12
Sensors
Optical sensors, connecting cables
Function Description
E65 SM Series
4-wire,
Rated operational voltage U e
10 - 30 V DC
Switching type: NPN, PNP
Insulated material
Plug-in connection M12 x 1
Degree of Protection IP68, IP69K
33 x 41 x 37 Reflected-light beam
With background suppression (Perfect Prox)
With background suppression (Perfect Prox)
100
100
Rated switching distance
S n mm
Type of light
Switching principle
Part no.
-
Light switching
Article no.
E65-SMPP100-HLD 135713
E65-SMPP100-HDD 135711
-
-
switching
E65-SMTD15-HLD
E65-SMTD15-HDD
E65-SMTS15-HAD
135733
135731
135735
Thru-beam photoelectric sensor
Source (for combination with detector)
Detector (for combination with source)
Source (for combination with detector)
E71 NanoView Series
4-wire,
Rated operational voltage U e
10 - 30 V DC
Switching type: PNP
Insulated material
Rectangular (20 x 12 x 32)
Degree of Protection IP66/IP67
Plug-in connection M8 x 1 Reflected-light beam
2 m connection cable
Reflex photoelectric sensor
Thru-beam photoelectric sensor
Plug-in connection M8 x 1 Reflex photoelectric sensor
Thru-beam photoelectric sensor
E76 IntelliView Series
8 conductor,
Rated operational voltage U e
10 - 30 V DC
Switching type: PNP
Plug-in connection M12 x 1
Degree of Protection IP67
Rectangular (50 x 50 x 25) Reflected-light beam
Beam: focused, forward viewing
Beam: straight
For combination with reflector
Detection of transparent objects
Source (for combination with detector)
Polarized light
Detector (for combination with source)
Color sensing
3 NO PNP outputs
100
350
800
1500
15000
15000
15000
2500
6000
450
Visible red
Infra-red
Visible red
Infra-red
Adjustable bright/dark switching
E71-FFDP-M8
E71-SDP-M8
E71-COP-M8
E71-NTBS-CA
Visible red
Infra-red
Infra-red -
E71-PRP-M8
E71-TBRP-M8
100518
100530
100428
100521
100526
100534
E76-CLRMKP-M12 166927
Connecting cables
Optical sensors, connecting cables
Style output side Style input side Length mm
Cable end, open
Plug, straight
Plug, angled
Coupling, straight
Coupling, angled
Coupling, straight
For use with Part no.
Article no.
2000
5000
10000
2000
5000
10000
1500
3000
5000
1500
3000
5000
DC sensors, 4 pole, 2, 3 or 4-wire connection,
M12
CSDS4A4CY2202
CSDS4A4CY2205
CSDS4A4CY2210
136292
136294
136296
CSDR4A4CY2202
CSDR4A4CY2205
CSDR4A4CY2210
136279
136282
136284
CSDS4A4CY2201.5-D 136316
CSDS4A4CY2203-D 136293
CSDS4A4CY2205-D 136295
CSDR4A4CY2201.5-D 136313
CSDR4A4CY2203-D 136315
CSDR4A4CY2205-D 136283
EATON CORPORATION CA08103003Z-EN 135
CA08103003Z_MOEM2015-EN.book Seite 134 Donnerstag, 7. April 2016 12:02 12
Sensors
Optical sensors
Optical sensors
Function Description
Comet Series
4-wire,
Rated operational voltage U e
10 - 30 V DC
Switching type: NPN, PNP
Insulated material
Plug-in connection M12 x 1
Degree of Protection IP67
M18 x 1 Reflected-light beam
Beam: straight
With background suppression (Perfect Prox)
50
200
Can be expanded with fiber optic cable → Accessories
With background suppression (Perfect Prox)
Beam: straight
225
610
Rated switching distance
S n mm
Type of light
Switching principle
Part no.
Visible red
Infra-red
Adjustable bright/dark switching
13104AQD07
13106AQD07
13103AQD07
13100AQD07
Visible red
14102AQD07 Reflex photoelectric sensor
Thru-beam photoelectric sensor
E58 Harsh Duty Series
4-wire,
Rated operational voltage U e
10 - 30 V DC
Switching type: NPN, PNP
Stainless steel
Plug-in connection M12 x 1
Degree of Protection IP69K
M18 x 1 Reflected-light beam
Non-polarized
Beam: straight
With background suppression
(Perfect Prox)
7600
24000
24000
M30 x 1.5
M30 x 1.5
Reflex photoelectric sensor
Reflex photoelectric sensor
Thru-beam photoelectric sensor
For combination with reflector
E67 Long Range Series
4-wire,
Rated operational voltage U e
18 – 30 V DC
Switching type: NPN
Plug-in connection M12 x 1, PNP
Degree of Protection IP67
Rectangular
(166 x 59 x 43)
Reflected-light beam with background suppression
(Perfect Prox) with background suppression
(Perfect Prox)
18000
Source (for combination with detector)
Detector (for combination with source)
250000
250000
250000
1000
1000
100
280
280
50
50
100
18000
-
12102AQD07
11102AQD07
Article no.
135577
135565
Visible red
-
-
Visible red
Light switching
Dark switching
Light switching
Dark switching
Dark switching
Light switching
Dark switching
Light switching
-
Dark switching
Light switching
E58-18DP50-HLP
E58-18DP50-HDP
E58-18DP100-HLP
135673
135671
135667
E58-18DP100-HDP 135665
E58-30DPS280-HDP 135681
E58-30DPS280-HLP 135683
E58-30RS18-HDP 135689
E58-30RS18-HLP
E58-30TS250-HAP
E58-30TD250-HDP
E58-30TD250-HLP
135691
135697
135693
135695
Infra-red Light switching
Dark switching
E67-LRDP100-HLD
E67-LRDP100-HDD
100548
100547
135605
135621
135597
135581
135657
134 EATON CORPORATION CA08103003Z-EN
CA08103003Z_MOEM2015-EN.book Seite 135 Donnerstag, 7. April 2016 12:02 12
Sensors
Optical sensors, connecting cables
Function Description
E65 SM Series
4-wire,
Rated operational voltage U e
10 - 30 V DC
Switching type: NPN, PNP
Insulated material
Plug-in connection M12 x 1
Degree of Protection IP68, IP69K
33 x 41 x 37 Reflected-light beam
With background suppression (Perfect Prox)
With background suppression (Perfect Prox)
100
100
Rated switching distance
S n mm
Type of light
Switching principle
Part no.
-
Light switching
Article no.
E65-SMPP100-HLD 135713
E65-SMPP100-HDD 135711
-
-
switching
E65-SMTD15-HLD
E65-SMTD15-HDD
E65-SMTS15-HAD
135733
135731
135735
Thru-beam photoelectric sensor
Source (for combination with detector)
Detector (for combination with source)
Source (for combination with detector)
E71 NanoView Series
4-wire,
Rated operational voltage U e
10 - 30 V DC
Switching type: PNP
Insulated material
Rectangular (20 x 12 x 32)
Degree of Protection IP66/IP67
Plug-in connection M8 x 1 Reflected-light beam
2 m connection cable
Reflex photoelectric sensor
Thru-beam photoelectric sensor
Plug-in connection M8 x 1 Reflex photoelectric sensor
Thru-beam photoelectric sensor
E76 IntelliView Series
8 conductor,
Rated operational voltage U e
10 - 30 V DC
Switching type: PNP
Plug-in connection M12 x 1
Degree of Protection IP67
Rectangular (50 x 50 x 25) Reflected-light beam
Beam: focused, forward viewing
Beam: straight
For combination with reflector
Detection of transparent objects
Source (for combination with detector)
Polarized light
Detector (for combination with source)
Color sensing
3 NO PNP outputs
100
350
800
1500
15000
15000
15000
2500
6000
450
Visible red
Infra-red
Visible red
Infra-red
Adjustable bright/dark switching
E71-FFDP-M8
E71-SDP-M8
E71-COP-M8
E71-NTBS-CA
Visible red
Infra-red
Infra-red -
E71-PRP-M8
E71-TBRP-M8
100518
100530
100428
100521
100526
100534
E76-CLRMKP-M12 166927
Connecting cables
Optical sensors, connecting cables
Style output side
Cable end, open
Plug, straight
Plug, angled
Complete assortment -> www.eaton.eu/ecat
Style input side
Coupling, straight
Coupling, angled
Coupling, straight
Length mm
For use with Part no.
Article no.
2000
5000
10000
2000
5000
10000
1500
3000
5000
1500
3000
5000
DC sensors, 4 pole, 2, 3 or 4-wire connection,
M12
CSDS4A4CY2202
CSDS4A4CY2205
CSDS4A4CY2210
136292
136294
136296
CSDR4A4CY2202
CSDR4A4CY2205
CSDR4A4CY2210
136279
136282
136284
CSDS4A4CY2201.5-D 136316
CSDS4A4CY2203-D 136293
CSDS4A4CY2205-D 136295
CSDR4A4CY2201.5-D 136313
CSDR4A4CY2203-D 136315
CSDR4A4CY2205-D 136283
EATON CA08103003Z-EN-INT
Safe and reliable: Timing relay, measuring relay and monitoring relay
136
C US
www.eaton.eu/Relays
NRTL
The range of electronic timing relay incorporates two different construction designs, which are adapted for differing application fields.
All timing relays are mounted on DIN top-hat rails. The measuring and monitoring relay EMR range is approved for worldwide use. Most of the relays feature multi-voltage coils.
They cover a wide range of applications:
– Current monitors for universal use
– Phase monitors for monitoring damage protection for individual system sections
– Phase sequence relays monitoring the rotating field
– Unbalance relays for reliable phase loss detection
US
of a rotating field
– Level monitoring relays for monitoring fill levels
– Earth leakage monitors for enhanced operational safety.
NRTL/C
EATON CA08103003Z-EN-INT
Timing Relay ETR –
Precision and Economic Switching
• Large choice of setting ranges
• Many timing functions for every requirement
• Remote setting via potentiometer
• Flexible connection using wide voltage range power supply
• Additional signal input even for different control voltage levels
Multi-functional three-phase monitor – compact rotary field monitoring
• Monitoring of phase sequence, phase loss, phase unbalance, overvoltage and undervoltage to protect the motor
• With optional neutral conductor monitoring
• Thresholds for overvoltage and undervoltage can be adjusted or fixed
• 2 changeover contacts for higher flexibility
Earth-leakage monitor and level relay EMR – the right solution for every application
• Enhanced safety by monitoring for earth-leakage using an earth-leakage monitor
• Fault correction without long standstill times
• Test button facilitates simple function testing
• Simple level monitoring and/or dry running protection
• Enhanced safety via open circuit principle
Single-phase current monitor EMR – for universal use
Precision current monitoring in AC and DC networks
• Adjustable triggering delay for bridging transitory current peaks.
• Status display via colored
LEDs
• Expansion of the measurement range possible via external current transformers
EATON CA08103003Z-EN-INT 137
CA08103003Z_MOEM2015-EN.book Seite 138 Donnerstag, 7. April 2016 12:02 12
Electronic relays
ETR timing relays
Electronic relaysETR timing relays
Function
Moeller® series
Time range Number of changeover contacts
Width mm
24 - 240 V AC,
50/60 Hz
24 - 240 V DC
Part no.
Article no.
400 V AC,
50/60 Hz
Part no.
Article no.
ETR4 timing relays
Changeover contact with a changeover time of 50 ms
Fixed timing function
Adjustable timing functions
With connection for potentiometer
Changeover contact can be converted to 2 timed contacts or
1 non-delayed contact and 1 timed contact
✓ -
✓ -
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -
3 - 60 s
0.05 s - 100 h
1
2
ETR2 timing relays
Fixed timing function
✓ -
✓ -
✓ -
✓ -
✓ -
✓ -
Pulse and pause times independently adjustable
Adjustable timing functions
✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
0.05 s - 100 h 1
2
1
2
1
2
22.5
ETR4-51-A
031884
ETR4-11-A
031882
ETR4-69-A
031891
ETR4-70-A
031888
ETR4-51-W
031885
-
ETR4-11-W
031883
ETR4-69-W
031887
17.5
-
-
-
-
-
-
-
-
12 - 240 V AC,
50/60 Hz
12 – 240 V DC
ETR2-69-D
119428
24 - 240 V AC,
50/60 Hz
24 - 48 V DC
ETR2-11
262684
ETR2-11-D
119426
ETR2-12
262686
ETR2-12-D
119427
ETR2-21
262687
ETR2-42
262688
ETR2-44
262730
-
ETR2-69
262689
CA08103003Z_MOEM2015-EN.book Seite 139 Donnerstag, 7. April 2016 12:02 12
Electronic relaysEMR Measuring and monitoring relays
Monitoring of
Electronic relays
EMR Measuring and monitoring relays
Monitoring voltage per phase
U
N
V AC
Adjustable threshold values
Threshold value Supply voltage Part no.
Article no.
Phase sequence relays
Monitoring of threephase networks
Phase failure detection at < 0.6 x U
Power supply from the measuring circuit
✓ ✓ - - - 200 - 500 V AC,
50/60 Hz
-
Phase imbalance monitoring relays
Power supply from the measuring circuit
On delay: None = 0 or adjustable from 0.1 to 30 s
Imbalance threshold values adjustable 2 - 25 % of mean value of phase voltages
Phase monitoring relays
Multi-functional
Power supply from the measuring circuit
On-delay/off-delay: none = 0 or adjustable between 0.1 - 30 s
Imbalance threshold values adjustable
2 - 25 % of mean value of phase voltages
✓ ✓ ✓ - - -
✓ ✓ ✓ - - -
22.5 mm Automatic phase sequence correction
Automatic phase sequence correction
160 - 300 V AC,
50/60 Hz
300 - 500 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ ✓ 90 - 170 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ 160 - 300 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ ✓ 180 - 280 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ ✓ 180 - 280 V AC,
50/60/400 Hz
✓ ✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ ✓ -
300 - 500 V AC,
50/60 Hz
300 - 500 V AC,
50/60/400 Hz
✓ ✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ ✓ -
350 - 580 V AC,
50/60 Hz
450 - 720 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ 530 - 820 V AC,
50/60 Hz
45 mm
On- and Off-delayed
Power supply from the measuring circuit
On-delay/off-delay: none = 0 or adjustable between 0.1 - 30 s
✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ -
160 - 300 V AC,
50/60 Hz
300 - 500 V AC,
50/60 Hz
380 V AC,
50/60 Hz
✓ -
✓ -
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓
-
✓ ✓ ✓ ✓ 400 V AC,
50/60 Hz
-
-
-
-
200 - 500 V AC,
50/60 Hz
EMR4-F500-2
221784
160 - 300 V AC,
50/60 Hz
300 - 500 V AC,
50/60 Hz
EMR5-A300-1-C
134230
EMR5-A400-1
134222
U
U
U max min.
max
120 - 170 V AC
90 - 130 V AC
U min
U max
220 - 300 V AC
160 - 230 V AC
U min
240 - 280 V AC
180 - 220 V AC
U
U
U max min max
240 - 280 V AC
180 - 220 V AC
U min
U max
420 - 500 V AC
300 - 380 V AC
U min
420 - 500 V AC
300 - 380 V AC
U max
U min
480 - 580 V AC
350 - 460 V AC
U max
U min
600 - 720 V AC
450 - 570 V AC
U max
U min
690 - 820 V AC
530 - 660 V AC
90 - 170 V AC,
50/60 Hz
160 - 300 V AC,
50/60 Hz
180 - 280 V AC,
50/60 Hz
180 - 280 V AC,
50/60/400 Hz
300 - 500 V AC,
50/60 Hz
300 - 500 V AC,
50/60/400 Hz
350 - 580 V AC,
50/60 Hz
450 - 720 V AC,
50/60 Hz
530 - 820 V AC,
50/60 Hz
EMR5-AWN170-1-E
134225
EMR5-AW300-1-C
134223
EMR5-AWN280-1-F
134226
EMR5-AWN280-1
134233
EMR5-AW500-1-D
134224
EMR5-AWN500-1
134234
EMR5-AWM580-2
134235
EMR5-AWM720-2
134236
EMR5-AWM820-2
134237
U max
U min
220 - 300 V AC
160 - 230 V AC
U max
U min
420 - 500 V AC
300 - 380 V AC
U
U max min
418 V AC,
342 V AC, fixed
U
U max min
440 V AC,
360 V AC, fixed
160 - 300 V AC,
50/60 Hz
300 - 500 V AC,
50/60 Hz
380 V AC,
50/60 Hz
400 V AC,
50/60 Hz
EMR5-W300-1-C
134227
EMR5-W500-1-D
134221
EMR5-W380-1
134228
EMR5-W400-1
134229
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 139
CA08103003Z_MOEM2015-EN.book Seite 138 Donnerstag, 7. April 2016 12:02 12
Electronic relays
ETR timing relays
Electronic relaysETR timing relays
Function
Moeller® series
Time range Number of changeover contacts
Width mm
24 - 240 V AC,
50/60 Hz
24 - 240 V DC
Part no.
Article no.
400 V AC,
50/60 Hz
Part no.
Article no.
ETR4 timing relays
Changeover contact with a changeover time of 50 ms
Fixed timing function
Adjustable timing functions
With connection for potentiometer
Changeover contact can be converted to 2 timed contacts or
1 non-delayed contact and 1 timed contact
✓ -
✓ -
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ -
3 - 60 s
0.05 s - 100 h
1
2
ETR2 timing relays
Fixed timing function
✓ -
✓ -
✓ -
✓ -
✓ -
✓ -
Pulse and pause times independently adjustable
Adjustable timing functions
✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
0.05 s - 100 h 1
2
1
2
1
2
22.5
ETR4-51-A
031884
ETR4-11-A
031882
ETR4-69-A
031891
ETR4-70-A
031888
ETR4-51-W
031885
-
ETR4-11-W
031883
ETR4-69-W
031887
17.5
-
-
-
-
-
-
-
-
12 - 240 V AC,
50/60 Hz
12 – 240 V DC
ETR2-69-D
119428
24 - 240 V AC,
50/60 Hz
24 - 48 V DC
ETR2-11
262684
ETR2-11-D
119426
ETR2-12
262686
ETR2-12-D
119427
ETR2-21
262687
ETR2-42
262688
ETR2-44
262730
-
ETR2-69
262689
CA08103003Z_MOEM2015-EN.book Seite 139 Donnerstag, 7. April 2016 12:02 12
Electronic relaysEMR Measuring and monitoring relays
Monitoring of
Electronic relays
EMR Measuring and monitoring relays
Monitoring voltage per phase
U
N
V AC
Adjustable threshold values
Threshold value Supply voltage Part no.
Article no.
Phase sequence relays
Monitoring of threephase networks
Phase failure detection at < 0.6 x U
Power supply from the measuring circuit
✓ ✓ - - - 200 - 500 V AC,
50/60 Hz
-
Phase imbalance monitoring relays
Power supply from the measuring circuit
On delay: None = 0 or adjustable from 0.1 to 30 s
Imbalance threshold values adjustable 2 - 25 % of mean value of phase voltages
Phase monitoring relays
Multi-functional
Power supply from the measuring circuit
On-delay/off-delay: none = 0 or adjustable between 0.1 - 30 s
Imbalance threshold values adjustable
2 - 25 % of mean value of phase voltages
✓ ✓ ✓ - - -
✓ ✓ ✓ - - -
22.5 mm Automatic phase sequence correction
Automatic phase sequence correction
160 - 300 V AC,
50/60 Hz
300 - 500 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ ✓ 90 - 170 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ 160 - 300 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ ✓ 180 - 280 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ ✓ 180 - 280 V AC,
50/60/400 Hz
✓ ✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ ✓ -
300 - 500 V AC,
50/60 Hz
300 - 500 V AC,
50/60/400 Hz
✓ ✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ ✓ -
350 - 580 V AC,
50/60 Hz
450 - 720 V AC,
50/60 Hz
✓ ✓ ✓ ✓ ✓ 530 - 820 V AC,
50/60 Hz
45 mm
On- and Off-delayed
Power supply from the measuring circuit
On-delay/off-delay: none = 0 or adjustable between 0.1 - 30 s
✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ -
✓ ✓ ✓ ✓ -
160 - 300 V AC,
50/60 Hz
300 - 500 V AC,
50/60 Hz
380 V AC,
50/60 Hz
✓ -
✓ -
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓
-
✓ ✓ ✓ ✓ 400 V AC,
50/60 Hz
-
-
-
-
200 - 500 V AC,
50/60 Hz
EMR4-F500-2
221784
160 - 300 V AC,
50/60 Hz
300 - 500 V AC,
50/60 Hz
EMR5-A300-1-C
134230
EMR5-A400-1
134222
U
U
U max min.
max
120 - 170 V AC
90 - 130 V AC
U min
U max
220 - 300 V AC
160 - 230 V AC
U min
240 - 280 V AC
180 - 220 V AC
U
U
U max min max
240 - 280 V AC
180 - 220 V AC
U min
U max
420 - 500 V AC
300 - 380 V AC
U min
420 - 500 V AC
300 - 380 V AC
U max
U min
480 - 580 V AC
350 - 460 V AC
U max
U min
600 - 720 V AC
450 - 570 V AC
U max
U min
690 - 820 V AC
530 - 660 V AC
90 - 170 V AC,
50/60 Hz
160 - 300 V AC,
50/60 Hz
180 - 280 V AC,
50/60 Hz
180 - 280 V AC,
50/60/400 Hz
300 - 500 V AC,
50/60 Hz
300 - 500 V AC,
50/60/400 Hz
350 - 580 V AC,
50/60 Hz
450 - 720 V AC,
50/60 Hz
530 - 820 V AC,
50/60 Hz
EMR5-AWN170-1-E
134225
EMR5-AW300-1-C
134223
EMR5-AWN280-1-F
134226
EMR5-AWN280-1
134233
EMR5-AW500-1-D
134224
EMR5-AWN500-1
134234
EMR5-AWM580-2
134235
EMR5-AWM720-2
134236
EMR5-AWM820-2
134237
U max
U min
220 - 300 V AC
160 - 230 V AC
U max
U min
420 - 500 V AC
300 - 380 V AC
U
U max min
418 V AC,
342 V AC, fixed
U
U max min
440 V AC,
360 V AC, fixed
160 - 300 V AC,
50/60 Hz
300 - 500 V AC,
50/60 Hz
380 V AC,
50/60 Hz
400 V AC,
50/60 Hz
EMR5-W300-1-C
134227
EMR5-W500-1-D
134221
EMR5-W380-1
134228
EMR5-W400-1
134229
138 EATON CORPORATION CA08103003Z-EN Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 140 Donnerstag, 7. April 2016 12:02 12
Electronic relays
EMR Measuring and monitoring relays
Electronic relaysEMR Measuring and monitoring relays
Level monitoring relays
Selectable: protection against running dry or overflowing
On-delay/off-delay: adjustable between
0.1 - 10 s
-
Monitoring of Adjustable pick-up time
Supply voltage Width mm
Fill level of conductive liquids 5 - 100 k Ω 220 - 240 V AC, 50/60 Hz 22.5
Fill level of conductive liquids
Mixture ratio of conductive liquids
250 Ω - 500 k Ω
250 Ω - 500 k Ω
5 - 100 k Ω
24 - 240 V AC, 50/60 Hz
24 - 240 V DC
45
220 - 240 V AC, 50/60 Hz 45
220 - 240 V AC, 50/60 Hz 22.5
Moeller® series
Part no.
Article no.
EMR4-N100-1-B
221789
EMR4-N500-2-A
221791
EMR4-N500-2-B
221790
EMR5-N80-1-B
134232
Insulation monitoring relays
Status indication via LEDs
Open-circuit principle
Test or reset with button on device or with control input
Configurable fault memory/ memory function
Configurable non-volatile fault memory
Status indication via LEDs
Open-circuit principle
Test or reset with button on device or with control input
Configurable fault memory/ memory function
Configurable non-volatile fault memory
Status indication via LEDs
Open-circuit principle
Test or reset with button on device or with control input
Configurable fault memory/ memory function
Configurable non-volatile fault memory
Wire break detection
Coupling module
Expands the rated voltage range for the EMR5-400-2-A to 690 V AC or 1000 V DC no supply voltage required
-
Insulation resistance in non-earthed
AC supply systems (two-phase, three-phase, four-phase systems)
Insulation resistance in non-earthed
DC supply systems (two-phase, three-phase systems)
Insulation resistance in non-earthed
AC supply systems (two-phase, three-phase, four-phase systems)
Insulation resistance in non-earthed
AC supply systems (three-phase, four-phase systems) insulation resistance in non-earthed
DC supply systems (three-phase systems)
-
1 - 110 k Ω
1 - 110 k Ω
1 - 110 k Ω
2 - 200 k Ω
Activation by dip switch
-
24 - 240 V AC,
13,5 - 400 Hz
24 - 240 V DC
24 - 240 V AC,
13,5 - 400 Hz
24 - 240 V DC
24 - 240 V AC,
13,5 - 400 Hz
24 - 240 V DC
Current monitoring relays
Monitoring of single-phase DC and AC networks
Switching hysteresis adjustable from 3 – 30 %
On delay: None = 0 or adjustable from 0.1 to 30 s
Extension of the measurement range possible with current transformers
Current measuring range
I ∼ /I=
A
3 - 30 mA
10 - 100 mA
0.1 - 1 A
0.3 - 1.5 A
1 - 5 A
3 - 15 A
0.3 - 1.5 A
1 - 5 A
3 - 15 A
22.5
22.5
45
45
EMR5-R250-1-A
153442
EMR5-R400-1-A
153443
EMR5-R400-2-A
153444
EMR5-RC690
153445
Supply voltage Width Part no.
Article no.
mm
24 - 240 V AC, 50/60 Hz
24 - 240 V DC
24 - 240 V AC, 50/60 Hz
24 - 240 V DC
22.5
22.5
220 - 240 V AC, 50/60 Hz 22.5
EMR4-I1-1-A
106942
EMR4-I15-1-A
106943
EMR4-I15-1-B
106944
CA08103003Z_MOEM2015-EN.book Seite 141 Donnerstag, 7. April 2016 12:02 12
Electronic relaysNotes
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
Electronic relays
Notes
EATON CORPORATION CA08103003Z-EN 141
CA08103003Z_MOEM2015-EN.book Seite 140 Donnerstag, 7. April 2016 12:02 12
Electronic relays
EMR Measuring and monitoring relays
Electronic relaysEMR Measuring and monitoring relays
Level monitoring relays
Selectable: protection against running dry or overflowing
On-delay/off-delay: adjustable between
0.1 - 10 s
-
Monitoring of Adjustable pick-up time
Supply voltage Width mm
Fill level of conductive liquids 5 - 100 k Ω 220 - 240 V AC, 50/60 Hz 22.5
Fill level of conductive liquids
Mixture ratio of conductive liquids
250 Ω - 500 k Ω
250 Ω - 500 k Ω
5 - 100 k Ω
24 - 240 V AC, 50/60 Hz
24 - 240 V DC
45
220 - 240 V AC, 50/60 Hz 45
220 - 240 V AC, 50/60 Hz 22.5
Moeller® series
Part no.
Article no.
EMR4-N100-1-B
221789
EMR4-N500-2-A
221791
EMR4-N500-2-B
221790
EMR5-N80-1-B
134232
Insulation monitoring relays
Status indication via LEDs
Open-circuit principle
Test or reset with button on device or with control input
Configurable fault memory/ memory function
Configurable non-volatile fault memory
Status indication via LEDs
Open-circuit principle
Test or reset with button on device or with control input
Configurable fault memory/ memory function
Configurable non-volatile fault memory
Status indication via LEDs
Open-circuit principle
Test or reset with button on device or with control input
Configurable fault memory/ memory function
Configurable non-volatile fault memory
Wire break detection
Coupling module
Expands the rated voltage range for the EMR5-400-2-A to 690 V AC or 1000 V DC no supply voltage required
-
Insulation resistance in non-earthed
AC supply systems (two-phase, three-phase, four-phase systems)
Insulation resistance in non-earthed
DC supply systems (two-phase, three-phase systems)
1 - 110 k Ω
Insulation resistance in non-earthed
AC supply systems (two-phase, three-phase, four-phase systems)
1 - 110 k Ω
Insulation resistance in non-earthed
AC supply systems (three-phase, four-phase systems) insulation resistance in non-earthed
DC supply systems (three-phase systems)
1 - 110 k Ω
2 - 200 k Ω
Activation by dip switch
-
24 - 240 V AC,
13,5 - 400 Hz
24 - 240 V DC
24 - 240 V AC,
13,5 - 400 Hz
24 - 240 V DC
24 - 240 V AC,
13,5 - 400 Hz
24 - 240 V DC
Current monitoring relays
Monitoring of single-phase DC and AC networks
Switching hysteresis adjustable from 3 – 30 %
On delay: None = 0 or adjustable from 0.1 to 30 s
Extension of the measurement range possible with current transformers
Current measuring range
I ∼ /I=
A
3 - 30 mA
10 - 100 mA
0.1 - 1 A
0.3 - 1.5 A
1 - 5 A
3 - 15 A
0.3 - 1.5 A
1 - 5 A
3 - 15 A
22.5
22.5
45
45
EMR5-R250-1-A
153442
EMR5-R400-1-A
153443
EMR5-R400-2-A
153444
EMR5-RC690
153445
Supply voltage Width Part no.
Article no.
mm
24 - 240 V AC, 50/60 Hz
24 - 240 V DC
24 - 240 V AC, 50/60 Hz
24 - 240 V DC
22.5
22.5
220 - 240 V AC, 50/60 Hz 22.5
EMR4-I1-1-A
106942
EMR4-I15-1-A
106943
EMR4-I15-1-B
106944
CA08103003Z_MOEM2015-EN.book Seite 141 Donnerstag, 7. April 2016 12:02 12
Electronic relaysNotes
140 EATON CORPORATION CA08103003Z-EN Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Electronic relays
Notes
Motors switching and protecting
DIL M Contactors and overload relays Z
• Trip indication auxiliary contact
Motor starter MSC-D
Operational motor switching
• Overload protection
• Short-circuit protective device
• Disconnector
Networked motors switching and protection
DIL M Contactor with
SmartWire-DT and electronic overload relay
• Remote actuation of the contactor
• Switching state read back
Motor starter MSC with
SmartWire-DT
• Remote actuation of the contactor
• Read back of the contactor switch state and PKZ
Motor starter MSC-DE
Operational motor switching
• Electronic wide-range overload protection
• Short-circuit protective device
• Disconnector
• Current range can be changed with interchangeable trip blocks
• DOL and reversing starter functionality
• Integrated emergency stop contactor for PLe / SIL 3 applications
• Wide-range overload protection
Circuit breaker NZM and contactor DIL M
• Short-circuit protective device
Motor starter MSC-DEA with
SmartWire-DT
• Remote actuation of the contactor
• Read back
– Contactor switch state and PKE
– Motor current
– Settings
– Motor thermal image
– Trip indication, overload/ short circuit/phase failure
EMS Electronic motor starters with SmartWire-DT
• Integrated control circuit supply
• Clockwise/counterclockwise actuation
• Feedback motor direction
• Toolless push-in connection
Circuit breaker NZM with SmartWire-DT and contactor DIL M
• Contactor PLC actuation
• Read back
– Circuit breaker switching state
– Motor current
– Load warnings
– Settings
– Trip reason
142 EATON CA08103003Z-EN-INT
Soft motor start and drives
Motor-protective circuit breakers PKZ and soft starter DS 7
• Overload protection
• Short-circuit protective device
• Soft start
PowerXL DE1 Variable speed starter to 7.5 kW
• Out-of-the-box commissioning without parameterization
• No special drives engineering skills or knowledge required
• Parameters can be set with a screwdriver when using the DXE-EXT-SET optional module
• Maximum machine availability thanks to trip-free design
PowerXL DC1 Variable frequency drives up to 22 kW
• V/Hz control with voltage boost
• Speed control for threephase motors and AC motors
PowerXL DA1 Variable frequency drives up to 250 kW
• EMC filter and braking transistor integrated
PowerXL DG1 Variable frequency drives to 160 kW
• For constant and variable torque applications
• Two freely usable slots for expansion cards
Networking motors soft motor start and drives
Motor starter MSC-DE with SmartWire-DT and soft starter DS 7
• Electronic wide-range
overload protection
• Short-circuit protective device
• Soft start
• Read back status
information
PowerXL DE1 Variable speed starter to 7.5 kW
Communication:
• CANopen (variant DE11)
• Integrated Modbus RTU
• Full integration into
SmartWire-DT (optional)
PowerXL DC1 Variable frequency drives up to 22 kW
Communication:
• Integrated CANopen,
Modbus RTU
• Full integration into
SmartWire-DT (optional)
PowerXL DA1 Variable frequency drives up to 250 kW
Communication:
• Integrated CANopen,
Modbus RTU
• Fieldbus modules optional
• Full integration into
SmartWire-DT (optional)
PowerXL DG1 Variable frequency drives to 160 kW
(PROFIBUS, PROFINET, etc.) optional
EATON CA08103003Z-EN-INT 143
Switch, protect, and drive your motors: Today and tomorrow
Using Eaton devices is the best way to make sure you are ready for the new ErP Directive. Our existing range of products for safely switching, protecting, and driving motors has not only been re-engineered in order to meet the Directive's requirements, but has also been expanded with ingenious new solutions, including the new PowerXL™ DE1 variable speed starter.
WP042001.indd 1
WP040003_EN.indd 1
White Paper
ErP directive 2009/125/EC www.eaton.eu
Motor protection for the
IE3 revolution
What the ErP directive means for switching and protection systems for electric motors
I>
re gu ion EC 640/20
09
Effect ive
1.1.20
15
White Paper
Jan Nowak
1st edition 2015
White Paper
ErP Directive 2009/125/EC www.eaton.eu
Successful implementation of the ErP Directive
Reducing losses with speed control
160 %
158 %
152 %
142 %
100 %
White Paper
Dipl.-Ing. Heribert Joachim
2nd edition, 2014
25.06.15 09:56
17.06.15 09:59
Successfully Implement the
ErP Directive
The third stage of the ErP directive will come into effect on 01/01/2017.
After this date, the directive will not only govern the use of IE2, IE3, and
IE4 motors, but will also place new requirements on motor starters and drives for the entire output range of 0 to 375 kW. For detailed information, please consult the white paper found at the following address: www.eaton.eu/moem-ee
IE3 motors – a new challenge for switchgear
IE3 premium efficiency motors are characterized not only by significantly improved efficiency, but also by lower internal resistance. As a result, their inrush currents can reach magnitudes of 14 x IN. This means that the contact mechanism in contactors may wear out very quickly and that nuisance tripping may become a problem with protective devices when used with these motors.
To consult our white paper on the subject, please visit: www.eaton.eu/moem-ee
On the safe side with Eaton motor starters
Eaton motor starters rated up to 375 kW have been specifically tested for operation with IE3 motors. The results show that the higher inrush currents produced by these motors pose no problem for our motor starters, meaning that there is absolutely no risk of having to deal with faster wear or increased maintenance. For detailed information, please visit our IE3 page: www.eaton.eu/IE3
Ingeniously connected with SmartWire-DT
The SmartWire-DT intelligent connection system is designed to lower wiring costs by up to 85 %. Moreover, it helps eliminate installation faults and reduces the amount of planning work required, not to mention it provides greater flexibility when it comes to selecting a PLC. In addition, connected devices can send analog and digital data concerning states, motor currents, and/or energy consumption, helping improve machine and system availability and optimize the use of power.
Build it in.
BreakerVisu – monitoring & analysis
NZM – circuit breaker
XV300 – HMI/PLC with multi-touch technology
KEY
SmartWire-DT
Data
Power
Module NZM – for SmartWire-DT
144 EATON CA08103003Z-EN-INT
Variable frequency
drive
DA1
Variable speed
starter
DE1
PKE 65 – motor-protective
circuit breakers
Soft starter
PKZ
+
DS7
Motor starter
PKE
+
DIL
Motor starter
PKZ
+
DIL
EATON CA08103003Z-EN-INT
HPU
145
Contactors DIL up to a high-performance
2600 A, efficiently and flexibly combinable
www.eaton.eu/moem-ee
146 www.eaton.eu/dil
The contactor series covers the entire performance range from minicontactor relay with 7 A up to a vacuum contactor at 2600 A. The combination with electronic overload relays or bimetal relays provides motor starters for the most varied of applications. All circuit breakers fulfil the demands for world-wide use and are compliant to UL/CSA,
CCC and shipping classifications. The motor protection systems are also
ATEX certified. The contactors are becoming more efficient, particularly due to the new Eco types for 15.5, 38, 72, 170 und 570 A, as well as through the many innovations with the motor starters, for example, such as SmartWire-DT.
An even higher level of operational safety is now guaranteed, for example, by the auxiliary contacts for electronic signals, which can reliably switch even the smallest signals such as feedback to the PLC.
EATON CA08103003Z-EN-INT
Contactor DILM up to 170 A Speedier wiring using spring-loaded terminals
The contactor series up to 170 A stands out with its compact dimensions. Contactors with DC and AC operation now have identical geometries.
• An identical range of accessories available for AC and DC operated devices simplifies engineering requirements
All contactor with DC actuation from DILM17 or higher feature an electronically controlled drive unit.
• Significantly less heat dissipation due to reduced sealing consumption
• Smaller control transformers because of lower pick-up
consumption
• Direct actuation from the PLC without coupling contactors up to 38 A.
Eaton provides proven quality with spring-loaded terminals.
The main current paths on PKZM0 and motor contactors up to
15.5 A all use spring-loaded terminals.
• Speedy wiring
• Highly reliable even with machines that vibrate excessively.
New electronic overload relay ZEB
The new electronic overload relay can be fitted directly to the contactors DILM. They cover a current range up to 175 A.
• Adjustable Class setting for protection at heavy duty start
• Manual or automatic reset can be selected to enable
universal application
• GF devices provide enhanced protection with earth faults.
100
95
90
85
80
75
70
0.1
Motor power (kW)
IE1
IE4
IE3
IE2
1 10 100 1000
Class Classifi cation speed
[1/min]
Continuos duty torque [Nm]
Classifi cation power
[kW]
Nominal effi ciency
[%]
Energy loss [W] as per IE1
IE3-ready with Eaton switchgear
IE2 1.500
35 5.5
87.4
87.7
693
676.5
-2.4%
IE3
IE4
1.500
1.500
35
35
5.5
5.5
89.6
92.0
572
440
-21.2%
-57.5% motors. The contactors' increased contact pressure force is designed to achieve an ideal balance between switchgear safety and energy efficiency, ensuring that the high-efficiency motors' higher inrush currents can be safely and reliably.
Simple, fast and reliable wiring
• The universally used standard components are combined for tool-less plug connection technology. On contactors up to
15.5 A, the DILM12-XSL or DILM12-XRL are fitted into the connectors rapidly and with optimum space savings without the need for tools.
• Front coil connections enable quick and reliable wiring
operations.
• Double box terminals on all contactors DILM up to 170 A guarantee reliable wiring even with different conductor cross-sections.
EATON CA08103003Z-EN-INT 147
4-pole contactors Contactors for reactive current compensation systems
The new 4-pole contactors from Eaton are optimized for AC-1 switched loads.
They are the specialists for applications, where the mains power is switched off or over, heating systems are switched and 4-pole loads are switched.
• Four compact contactors cover the performance range up to
200 A
• Identical accessories for 3 and 4-pole contactors guarantee efficient engineering.
The contactors for capacitor DILK have been developed on the basis of the DILM contactors. The installation and connection as well as the handling are identical with the standard contactors. These contactors feature series resistors in addition to special, weld-free contact material. The capacitors are precharged via a special early-make auxiliary switch, and only then do the main contacts close and conduct continuous
current.
Mini Contactor Relays DILE
Contactor relays DILA
Safety technology
The range of mini contactor relays has been extended by three performance ranges. The new DILEM12 allows motors up to
5.5 kW to be controlled reliably.
• Compact dimensions for small installation spaces
• Extension of the small contactor relay range up to 5.5 kW
Safety technology is constantly increasing in significance.
Contactors for a safe standstill are used here.
• Reliable feedback of the switching state of the contactor using mirror contacts.
• Long enabling circuits with low magnitude signals are switched reliably by the new electronic-enabled auxiliary switches. The integrated microswitches safely switch through the lowest signals. The auxiliary contactor DILA perfectly complements the motor contactors DILM.
• Auxiliary contacts specially designed for the contactor relays ensure safe identification.
Thermistor overload relay EMT6
Remarkable functional versatility in the smallest possible space. The EMT 6 thermistor overload relay protects machines against overtemperatures during severe starting duty, braking duty, undervoltage and overvoltage and high switching frequency. The temperature is monitored by means of a thermistor, directly on the motor winding. Another field of application for the EMT 6 is the monitoring of temperatures in bearings, gearboxes, oils and coolants. Three types with differing functions are available: EMT6, EMT6-DB, EMT6-DBK.
The EMT 6-DBK is the most versatile with functions such as automatic or manual operation, recognition of short circuits in the sensor circuit and zero-voltage safety.
148 EATON CA08103003Z-EN-INT
B 1 2 3 4 EN/ISO13849-1, PL "d"
Contactor monitoring device CMD
The CMD (Contactor Monitoring Device) monitors the main contacts of a contactor for welding. For this purpose, it compares the contactor control voltage with the state of the main contacts, which are indicated reliably by a mirror contact (IEC
EN 60947-4-1 Ann. F). If the contactor coil is de-energized and the contactor does not drop out, the CMD trips the backup
circuit breaker, motor-protective circuit breaker or switch- disconnector via an undervoltage release.
Large contactors up to 2600 A
All contactors DILM and DILH from 185 A to 2200 A are
available with electronically-controlled drives. This provides outstanding benefits for your application:
• Flexible actuation
• Considerably lower control panel temperatures due to reduced sealing power
• Considerably greater control voltage tolerance than required by the standard, ensuring greater reliability with voltage deviations
• Integrated suppressor
• Auxiliary contact contacts: 2 NO, 2 NC
• In the premium version, four wide-range devices cover the entire voltage range.
Contactors DILM from 580 A and DILH from 1400 A are
vacuum contactors with significant benefits in comparison to air contactors:
• The electrical service life is significantly longer than on air contactors.
• A higher packing density and cleaner distribution compartment are possible, since there are no open arcs and therefore no escaping gases.
Intelligent networking
The conventional wiring used in control circuits for motor starters and contactors requires considerable time and effort: each motor starter or contactor needs to be wired individually and then separately connected to the PLC’s input/output modules. This not only takes a lot of time, but also makes wiring and operating faults much more likely. When used together with SmartWire-DT, our xStart contactors eliminate the need for this control wiring, as well as for the PLC’s input/ output modules, minimizing the time required for wiring and commissioning.
EATON CA08103003Z-EN-INT 149
Overview of motor protection up to 1000 A
Electronic and electrical overload relays, thermistor protective relays
Contactor
Moeller® series
TYPE DIL EEM EM EM12* M7
Rated operational power AC-3
Rated operational
current AC-3
400V
400V
3
6.6
4
9
5.5
12
3
7
Rated operational power AC-1
*For motors up to IE2!
40°C
22 22 22 22
Bimetal relays
M9 M12 M15* M17 M25 M32 M38* M40 M50 M65 M72*
4 5.5
7.5
7.5
11 15 18.5
18.5
22 30 37
9
22
12
22
15.5
22
18
40
25
45
32
45
38
45
40
60
50
80
65
98
72
98
TYPE
Overload release setting range
Electronic
overload relays
ZE
0.1 - 12 A
ZB12
0.1 - 16 A
ZB32
0.1 - 38 A
ZB65
6 - 75 A
TYPE
Overload release setting range
Thermistor
overload relay
ZEB12
0.33 - 20 A
ZEB32
0.33 - 45 A
ZEB65
9 - 100 A
TYPE
150 EATON CA08103003Z-EN-INT
EMT6, EMT6-K, EMT6-DB, …
M80 M95 M115 M150 M170* M185A M225A M250 M300A M400 M500 M580 M650 M750 M820 M1000
37 45 55 75 90 90 110 132 160 200 250 315 355 400 450 560
80 95
110 130
*For motors up to IE2!
115
160
150
190
170
225
185
337
225
356
250
400
300
430
400
612
500
857
580
980
650
1041
750
1102
820
1225
1000
1225
ZB150
35 - 175 A
Z5-../FF225A
50 - 250 A
Z5-../FF250
50 - 300 A
ZW7
42 - 630 A
ZEB150
20 - 175 A
ZEB225A
35 - 175 A
… EMT6KDB, EMT6-DBK
EATON CA08103003Z-EN-INT 151
CA08103003Z_MOEM2015-EN.book Seite 152 Donnerstag, 7. April 2016 12:02 12
Mini contactor relays, contactor relays
Contactors, miniature contactors, Contactor relays Moeller® series
Contactors, miniature contactors, Contactor relays
DILEM contactors
Screw terminals
3
4
5.5
3
4
Max. rating for three-phase motors, 50 - 60 Hz
AC-3
380 V
400 V
660 V
690 V
P kW
P kW
Rated operational current
AC-1
Conventional free air thermal current, 3 pole,
50 - 60 Hz
Open at 40 °C
I th
=I e
A
4
4
4
4
3
3
22
22
22
22
22
22
5.5
Spring-loaded terminals
3
3
4
4
4
4
3
3
22
22
22
22
Contacts AC operation
230 V 50 Hz, 240 V 60 Hz
N/O =
Normally open
N/C =
Normally closed
Part no.
Article no.
-
1 N/O DILEEM-10(230V50HZ,240V60HZ)
051608
1 NC DILEEM-01(230V50HZ,240V60HZ)
051633
-
-
1 N/O -
1 N/O -
DILEM-10(230V50HZ,240V60HZ)
051786
1 NC DILEM-01(230V50HZ,240V60HZ)
051795
DILEM12-10(230V50HZ,240V60HZ)
127075
1 NC DILEM12-01(230V50HZ,240V60HZ)
127091
AC operation
110 V 50 Hz, 120 V 60 Hz
Part no.
Article no.
DILEEM-10(110V50HZ,120V60HZ)
051611
DILEEM-01(110V50HZ,120V60HZ)
051636
DILEM-10(110V50HZ,120V60HZ)
051783
DILEM-01(110V50HZ,120V60HZ)
051792
DILEM12-10(110V50HZ,120V60HZ)
127072
DILEM12-01(110V50HZ,120V60HZ)
127088
-
-
1 N/O -
1 N/O -
DILEEM-10-C(230V50HZ,240V60HZ)
230042
1 NC DILEEM-01-C(230V50HZ,240V60HZ)
230135
DILEM-10-C(230V50HZ,240V60HZ)
230164
1 NC DILEM-01-C(230V50HZ,240V60HZ)
230166
-
-
DILEM-10-C(110V50HZ,120V60HZ)
231658
DILEM-01-C(110V50HZ,120V60HZ)
231681
DILER Mini-contactors
Screw terminals
10
-
-
-
10
10
4 N/O DILER-40(230V50HZ,240V60HZ)
051759
3 N/O 1 NC DILER-31(230V50HZ,240V60HZ)
051768
2 N/O 2 NC DILER-22(230V50HZ,240V60HZ)
051777
DILER-40(110V50HZ,120V60HZ)
051756
DILER-31(110V50HZ,120V60HZ)
051765
DILER-22(110V50HZ,120V60HZ)
051774
DC operation
24 V DC
Part no.
Article no.
DILEEM-10-G(24VDC)
051643
DILEEM-01-G(24VDC)
051650
DILEM-10-G(24VDC)
010213
DILEM-01-G(24VDC)
010343
DILEM12-10-G(24VDC)
127132
DILEM12-01-G(24VDC)
127137
DILEEM-10-G-C(24VDC)
230052
DILEEM-01-G-C(24VDC)
230155
DILEM-10-G-C(24VDC)
230165
DILEM-01-G-C(24VDC)
230167
DILER-40-G(24VDC)
010223
DILER-31-G(24VDC)
010157
DILER-22-G(24VDC)
010042
Spring-loaded terminals
-
-
-
-
-
10
10
10
4 N/O DILER-40-C(230V50HZ,240V60HZ)
230239
3 N/O 1 NC DILER-31-C(230V50HZ,240V60HZ)
230178
2 N/O 2 NC DILER-22-C(230V50HZ,240V60HZ)
230176
DILER-40-C(110V50HZ,120V60HZ)
231841
DILER-31-C(110V50HZ,120V60HZ)
231818
DILER-22-C(110V50HZ,120V60HZ)
231793
DILER-40-G-C(24VDC)
230241
DILER-31-G-C(24VDC)
230179
DILER-22-G-C(24VDC)
230177
DILA relays
Screw terminals
-
-
-
-
-
16
16
16
4 N/O DILA-40(230V50HZ,240V60HZ)
276329
3 N/O 1 NC DILA-31(230V50HZ,240V60HZ)
276364
2 N/O 2 NC DILA-22(230V50HZ,240V60HZ)
276399
DILA-40(110V50HZ,120V60HZ)
276326
DILA-31(110V50HZ,120V60HZ)
276361
DILA-22(110V50HZ,120V60HZ)
276396
DILA-40(24VDC)
276344
DILA-31(24VDC)
276379
DILA-22(24VDC)
276414
Spring-loaded terminals
-
-
-
-
-
16
16
16
4 N/O DILAC-40(230V50HZ,240V60HZ)
276441
3 N/O 1 NC DILAC-31(230V50HZ,240V60HZ)
276473
2 N/O 2 NC DILAC-22(230V50HZ,240V60HZ)
276505
DILAC-40(110V50HZ,120V60HZ)
276438
DILAC-31(110V50HZ,120V60HZ)
276470
DILAC-22(110V50HZ,120V60HZ)
276502
DILAC-40(24VDC)
276456
DILAC-31(24VDC)
276488
DILAC-22(24VDC)
276520
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 153 Donnerstag, 7. April 2016 12:02 12
Moeller® series
DILE auxiliary contact modules, DILE accessories
For use with
Auxiliary contact modules
Screw terminals
DILEM-10(-G)(…)
DILEM-4(-G)(…)
DILEEM-10(-G)(…)
DILEM12-10(-G)(…)
DILEM-10(-G)(…)
DILEM-01(-G)(…)
DILEM-4(-G)(…)
DILER40(-G)
DILER31(-G)
DILER22
DILEEM-10(-G)(…)
DILEEM-01(-G)(…)
DILEM12-10(-G)(…)
DILEM12-01(-G)(…)
Spring-loaded terminals
DILE(E)M-10-C(-G)(…)
DILE(E)M-01-C(-G)(…)
DILER40(-G)-C
DILER31(-G)-C
DILER22-C
Suppressor circuit
Varistor suppressor
DILE...
Mini contactor relays, contactor relays
DILE auxiliary contact modules, DILE accessories
Contacts
N/O = Normally open
N/O
E make
: NO earlyN/C = Normally closed
NC
L
=NC latebreak
Part no.
Article no.
-
-
-
-
-
-
-
-
-
-
-
1 N/O
E
-
1 N/O
E
-
-
-
-
-
-
1 N/O
E
-
-
1 N/O
2 N/O
-
1 N/O
2 N/O
-
-
1 N/O
2 N/O
3 N/O
4 N/O
1 N/O
-
1 N/O
1 N/O
2 N/O
3 N/O
4 N/O
1 N/O
-
-
-
-
-
-
-
-
-
-
-
1 NC
L
-
1 NC
L
-
-
-
-
-
-
1 NC
L
-
2 NC
1 NC
2 NC
-
2 NC
1 NC
-
4 NC
3 NC
2 NC
1 NC
-
1 NC
1 NC
4 NC
3 NC
2 NC
-
1 NC
1 NC
02DILEM
11DILEM
22DILEM
02DILE
11DILE
20DILE
11DDILE
04DILE
13DILE
22DILE
31DILE
40DILE
22DDILE
11DILE-C
04DILE-C
13DILE-C
22DILE-C
31DILE-C
40DILE-C
22DDILE-C
010064
010080
010112
010240
010224
010208
049824
010256
002397
010288
048912
010304
049823
230257
230258
230259
230260
230262
230263
230264
VGDILE250 010336
RC suppressor
DILE...
RCDILE250 046320
Mechanical interlock
For contactors with the same or different magnet system.
0 mm distance between relays.
Mechanical lifespan 2.5 x 10 6 Operations.
Additional auxiliary contact modules possible.
DILE… -
Paralleling link
Consisting of two 4 pole paralleling links
DILEEM
DILEM12
DILEM
-
-
-
-
-
MVDILE 010113
P1DILEM 019095
EATON CORPORATION CA08103003Z-EN 153
CA08103003Z_MOEM2015-EN.book Seite 153 Donnerstag, 7. April 2016 12:02 12
Moeller® series
DILE auxiliary contact modules, DILE accessories
For use with
Auxiliary contact modules
Screw terminals
DILEM-10(-G)(…)
DILEM-4(-G)(…)
DILEEM-10(-G)(…)
DILEM12-10(-G)(…)
DILEM-10(-G)(…)
DILEM-01(-G)(…)
DILEM-4(-G)(…)
DILER40(-G)
DILER31(-G)
DILER22
DILEEM-10(-G)(…)
DILEEM-01(-G)(…)
DILEM12-10(-G)(…)
DILEM12-01(-G)(…)
Spring-loaded terminals
DILE(E)M-10-C(-G)(…)
DILE(E)M-01-C(-G)(…)
DILER40(-G)-C
DILER31(-G)-C
DILER22-C
Suppressor circuit
Varistor suppressor
DILE...
Mini contactor relays, contactor relays
DILE auxiliary contact modules, DILE accessories
Contacts
N/O = Normally open
N/O
E make
: NO earlyN/C = Normally closed
NC
L
=NC latebreak
Part no.
Article no.
-
-
-
-
-
-
-
-
-
-
-
1 N/O
E
-
1 N/O
E
-
-
-
-
-
-
1 N/O
E
-
-
1 N/O
2 N/O
-
1 N/O
2 N/O
-
-
1 N/O
2 N/O
3 N/O
4 N/O
1 N/O
-
1 N/O
1 N/O
2 N/O
3 N/O
4 N/O
1 N/O
-
-
-
-
-
-
-
-
-
-
-
1 NC
L
-
1 NC
L
-
-
-
-
-
-
1 NC
L
-
2 NC
1 NC
2 NC
-
2 NC
1 NC
-
4 NC
3 NC
2 NC
1 NC
-
1 NC
1 NC
4 NC
3 NC
2 NC
-
1 NC
1 NC
02DILEM
11DILEM
22DILEM
02DILE
11DILE
20DILE
11DDILE
04DILE
13DILE
22DILE
31DILE
40DILE
22DDILE
11DILE-C
04DILE-C
13DILE-C
22DILE-C
31DILE-C
40DILE-C
22DDILE-C
010064
010080
010112
010240
010224
010208
049824
010256
002397
010288
048912
010304
049823
230257
230258
230259
230260
230262
230263
230264
VGDILE250 010336
RC suppressor
DILE...
RCDILE250 046320
Mechanical interlock
For contactors with the same or different magnet system.
0 mm distance between relays.
Mechanical lifespan 2.5 x 10 6 Operations.
Additional auxiliary contact modules possible.
DILE… -
Paralleling link
Consisting of two 4 pole paralleling links
DILEEM
DILEM12
DILEM
-
-
-
-
-
MVDILE 010113
P1DILEM 019095
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 154 Donnerstag, 7. April 2016 12:02 12
Contactors
System overview
System overview
7 1
5
57
NO
58
65
NC
66
Range (s)
1
10
100
Time
6
8
5
2
3
9
4
4
3
2
1
6
5
7
Contactors
Suppressor circuits
Overload relays, thermal
Overload relay, electronic
Top mounting auxiliary contact
Top mounting auxiliary contact, spring-cage terminals
Side-mounting auxiliary contact
7 1
2
3
5
5
6
EATON CA08103003Z-EN-INT
7
1
Moeller® series
8
7
9
6
5
4
3
2
1 Contactors
Suppressor circuits
Overload relays, thermal
Overload relay, electronic
Top mounting auxiliary contact
Electronic timer module
Side-mounting auxiliary contact
Motor suppressor module
SmartWire-DT contactor module
3
7
1
4
CA08103003Z_MOEM2015-EN.book Seite 155 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Basic devices up to 170 A, screw terminals
Max. rating for three-phase motors, 50 - 60 Hz
AC-3
380 V
400 V
660 V
690 V
P kW
P kW
Rated operational current
AC-1
Conventional free air thermal current,
3 pole, 50 - 60 Hz
Open at 40 °C
I th
=I e
A
AC operation
230 V 50 Hz, 240 V 60 Hz
Part no.
Article no.
Basic device
Screw terminals
17
21
14
17
21
23
11
14
7
11
30
35
35
6.5
6.5
7
4.5
4.5
3.5
3.5
90
96
63
75
96
11
15
15
18.5
7.5
11
7.5
7.5
18.5
18.5
22
30
37
5.5
5.5
7.5
4
4
3
3
55
75
37
45
90
45
45
45
45
45
60
40
45
22
40
80
98
98
22
22
22
22
22
22
22
110
130
160
190
225
Basic devices up to 170 A, screw terminals
AC operation
110 V 50 Hz, 120 V 60 Hz
Part no.
Article no.
Contactors
DC operation
24 V DC
Part no.
Article no.
DILM7-10(230V50HZ,240V60HZ)
276550
DILM7-01(230V50HZ,240V60HZ)
276585
DILM9-10(230V50HZ,240V60HZ)
276690
DILM9-01(230V50HZ,240V60HZ)
276725
DILM12-10(230V50HZ,240V60HZ)
276830
DILM12-01(230V50HZ,240V60HZ)
276865
DILM15-10(230V50HZ,240V60HZ)
290058
DILM15-01(230V50HZ,240V60HZ)
290093
DILM17-10(230V50HZ,240V60HZ)
277004
DILM17-01(230V50HZ,240V60HZ)
277036
DILM25-10(230V50HZ,240V60HZ)
277132
DILM25-01(230V50HZ,240V60HZ)
277164
DILM32-10(230V50HZ,240V60HZ)
277260
DILM32-01(230V50HZ,240V60HZ)
277292
DILM38-10(230V50HZ,240V60HZ)
112428
DILM38-01(230V50HZ,240V60HZ)
112456
DILM40(230V50HZ,240V60HZ)
277766
DILM50(230V50HZ,240V60HZ)
277830
DILM65(230V50HZ,240V60HZ)
277894
DILM72(230V50HZ,240V60HZ)
107670
DILM80(230V50HZ,240V60HZ)
239402
DILM95(230V50HZ,240V60HZ)
239480
DILM115(RAC240)
239548
DILM150(RAC240)
239588
DILM170(RAC240)
107013
DILM7-10(110V50HZ,120V60HZ)
276547
DILM7-01(110V50HZ,120V60HZ)
276582
DILM9-10(110V50HZ,120V60HZ)
276687
DILM9-01(110V50HZ,120V60HZ)
276722
DILM12-10(110V50HZ,120V60HZ)
276827
DILM12-01(110V50HZ,120V60HZ)
276862
DILM15-10(110V50HZ,120V60HZ)
290055
DILM15-01(110V50HZ,120V60HZ)
290090
DILM17-10(110V50HZ,120V60HZ)
277001
DILM17-01(110V50HZ,120V60HZ)
277033
DILM25-10(110V50HZ,120V60HZ)
277129
DILM25-01(110V50HZ,120V60HZ)
277161
DILM32-10(110V50HZ,120V60HZ)
277257
DILM32-01(110V50HZ,120V60HZ)
277289
DILM38-10(110V50HZ,120V60HZ)
112425
DILM38-01(110V50HZ,120V60HZ)
112453
DILM40(110V50HZ,120V60HZ)
277763
DILM50(110V50HZ,120V60HZ)
277827
DILM65(110V50HZ,120V60HZ)
277891
DILM72(110V50HZ,120V60HZ)
109191
DILM80(110V50HZ,120V60HZ)
239399
DILM95(110V50HZ,120V60HZ)
239477
DILM115(RAC120)
239547
DILM150(RAC120)
239587
DILM170(RAC120)
107012
DILM7-10(24VDC)
276565
DILM7-01(24VDC)
276600
DILM9-10(24VDC)
276705
DILM9-01(24VDC)
276740
DILM12-10(24VDC)
276845
DILM12-01(24VDC)
276880
DILM15-10(24VDC)
290073
DILM15-01(24VDC)
290108
DILM17-10(RDC24)
277018
DILM17-01(RDC24)
277050
DILM25-10(RDC24)
277146
DILM25-01(RDC24)
277178
DILM32-10(RDC24)
277274
DILM32-01(RDC24)
277306
DILM38-10(RDC24)
112442
DILM38-01(RDC24)
112470
DILM40(RDC24)
277780
DILM50(RDC24)
277844
DILM65(RDC24)
277908
DILM72(RDC24)
107671
DILM80(RDC24)
239416
DILM95(RDC24)
239510
DILM115(RDC24)
239555
DILM150(RDC24)
239591
DILM170(RDC24)
107016
Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 155
CA08103003Z_MOEM2015-EN.book Seite 155 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Basic devices up to 170 A, screw terminals
Max. rating for three-phase motors, 50 - 60 Hz
AC-3
380 V
400 V
660 V
690 V
P kW
P kW
Rated operational current
AC-1
Conventional free air thermal current,
3 pole, 50 - 60 Hz
Open at 40 °C
I th
=I e
A
AC operation
230 V 50 Hz, 240 V 60 Hz
Part no.
Article no.
Basic device
Screw terminals
17
21
14
17
21
23
11
14
7
11
30
35
35
6.5
6.5
7
4.5
4.5
3.5
3.5
90
96
63
75
96
11
15
15
18.5
7.5
11
7.5
7.5
18.5
18.5
22
30
37
5.5
5.5
7.5
4
4
3
3
55
75
37
45
90
45
45
45
45
45
60
40
45
22
40
80
98
98
22
22
22
22
22
22
22
110
130
160
190
225
Basic devices up to 170 A, screw terminals
AC operation
110 V 50 Hz, 120 V 60 Hz
Part no.
Article no.
Contactors
DC operation
24 V DC
Part no.
Article no.
DILM7-10(230V50HZ,240V60HZ)
276550
DILM7-01(230V50HZ,240V60HZ)
276585
DILM9-10(230V50HZ,240V60HZ)
276690
DILM9-01(230V50HZ,240V60HZ)
276725
DILM12-10(230V50HZ,240V60HZ)
276830
DILM12-01(230V50HZ,240V60HZ)
276865
DILM15-10(230V50HZ,240V60HZ)
290058
DILM15-01(230V50HZ,240V60HZ)
290093
DILM17-10(230V50HZ,240V60HZ)
277004
DILM17-01(230V50HZ,240V60HZ)
277036
DILM25-10(230V50HZ,240V60HZ)
277132
DILM25-01(230V50HZ,240V60HZ)
277164
DILM32-10(230V50HZ,240V60HZ)
277260
DILM32-01(230V50HZ,240V60HZ)
277292
DILM38-10(230V50HZ,240V60HZ)
112428
DILM38-01(230V50HZ,240V60HZ)
112456
DILM40(230V50HZ,240V60HZ)
277766
DILM50(230V50HZ,240V60HZ)
277830
DILM65(230V50HZ,240V60HZ)
277894
DILM72(230V50HZ,240V60HZ)
107670
DILM80(230V50HZ,240V60HZ)
239402
DILM95(230V50HZ,240V60HZ)
239480
DILM115(RAC240)
239548
DILM150(RAC240)
239588
DILM170(RAC240)
107013
DILM7-10(110V50HZ,120V60HZ)
276547
DILM7-01(110V50HZ,120V60HZ)
276582
DILM9-10(110V50HZ,120V60HZ)
276687
DILM9-01(110V50HZ,120V60HZ)
276722
DILM12-10(110V50HZ,120V60HZ)
276827
DILM12-01(110V50HZ,120V60HZ)
276862
DILM15-10(110V50HZ,120V60HZ)
290055
DILM15-01(110V50HZ,120V60HZ)
290090
DILM17-10(110V50HZ,120V60HZ)
277001
DILM17-01(110V50HZ,120V60HZ)
277033
DILM25-10(110V50HZ,120V60HZ)
277129
DILM25-01(110V50HZ,120V60HZ)
277161
DILM32-10(110V50HZ,120V60HZ)
277257
DILM32-01(110V50HZ,120V60HZ)
277289
DILM38-10(110V50HZ,120V60HZ)
112425
DILM38-01(110V50HZ,120V60HZ)
112453
DILM40(110V50HZ,120V60HZ)
277763
DILM50(110V50HZ,120V60HZ)
277827
DILM65(110V50HZ,120V60HZ)
277891
DILM72(110V50HZ,120V60HZ)
109191
DILM80(110V50HZ,120V60HZ)
239399
DILM95(110V50HZ,120V60HZ)
239477
DILM115(RAC120)
239547
DILM150(RAC120)
239587
DILM170(RAC120)
107012
DILM7-10(24VDC)
276565
DILM7-01(24VDC)
276600
DILM9-10(24VDC)
276705
DILM9-01(24VDC)
276740
DILM12-10(24VDC)
276845
DILM12-01(24VDC)
276880
DILM15-10(24VDC)
290073
DILM15-01(24VDC)
290108
DILM17-10(RDC24)
277018
DILM17-01(RDC24)
277050
DILM25-10(RDC24)
277146
DILM25-01(RDC24)
277178
DILM32-10(RDC24)
277274
DILM32-01(RDC24)
277306
DILM38-10(RDC24)
112442
DILM38-01(RDC24)
112470
DILM40(RDC24)
277780
DILM50(RDC24)
277844
DILM65(RDC24)
277908
DILM72(RDC24)
107671
DILM80(RDC24)
239416
DILM95(RDC24)
239510
DILM115(RDC24)
239555
DILM150(RDC24)
239591
DILM170(RDC24)
107016
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 156 Donnerstag, 7. April 2016 12:02 12
Contactors
Basic devices up to 170 A, spring-cage terminals Moeller® series
Basic devices up to 170 A, spring-cage terminals
Max. rating for three-phase motors, 50 - 60 Hz
AC-3
380 V
400 V
660 V
690 V
P kW
P kW
Basic device
Spring-loaded terminals
5.5
5.5
7.5
4
4
3
3
6.5
6.5
7
4.5
4.5
3.5
3.5
7.5
7 22
Spring-cage terminals on auxiliary and control circuit terminals
7.5
11 40
7.5
11
11
11
14
14
40
45
45
15
15
18.5
22
30
23
30
17
17
35
60
80
45
45
98
22
22
22
22
22
22
22
Rated operational current
AC-1
Conventional free air thermal current,
3 pole, 50 - 60 Hz
Open at 40 °C
I th
=I e
A
AC operation
230 V 50 Hz, 240 V 60 Hz
Part no.
Article no.
AC operation
110 V 50 Hz, 120 V 60 Hz
Part no.
Article no.
DILMC7-10(230V50HZ,240V60HZ)
277389
DILMC7-01(230V50HZ,240V60HZ)
277421
DILMC9-10(230V50HZ,240V60HZ)
277453
DILMC9-01(230V50HZ,240V60HZ)
277485
DILMC12-10(230V50HZ,240V60HZ)
277517
DILMC12-01(230V50HZ,240V60HZ)
277549
DILMC15-10(230V50HZ,240V60HZ)
293911
DILMC15-01(230V50HZ,240V60HZ)
293946
DILMC7-10(110V50HZ,120V60HZ)
277386
DILMC7-01(110V50HZ,120V60HZ)
277418
DILMC9-10(110V50HZ,120V60HZ)
277450
DILMC9-01(110V50HZ,120V60HZ)
277482
DILMC12-10(110V50HZ,120V60HZ)
277514
DILMC12-01(110V50HZ,120V60HZ)
277546
DILMC15-10(110V50HZ,120V60HZ)
293908
DILMC15-01(110V50HZ,120V60HZ)
293943
DILMC17-10(230V50HZ,240V60HZ)
277581
DILMC17-01(230V50HZ,240V60HZ)
277611
DILMC25-10(230V50HZ,240V60HZ)
277641
DILMC25-01(230V50HZ,240V60HZ)
277671
DILMC32-10(230V50HZ,240V60HZ)
277701
DILMC32-01(230V50HZ,240V60HZ)
277731
DILMC40(230V50HZ,240V60HZ)
277965
DILMC50(230V50HZ,240V60HZ)
277995
DILMC65(230V50HZ,240V60HZ)
278025
DILMC17-10(110V50HZ,120V60HZ)
277578
DILMC17-01(110V50HZ,120V60HZ)
277608
DILMC25-10(110V50HZ,120V60HZ)
277638
DILMC25-01(110V50HZ,120V60HZ)
277668
DILMC32-10(110V50HZ,120V60HZ)
277698
DILMC32-01(110V50HZ,120V60HZ)
277728
DILMC40(110V50HZ,120V60HZ)
277962
DILMC50(110V50HZ,120V60HZ)
277992
DILMC65(110V50HZ,120V60HZ)
278022
DC operation
24 V DC
Part no.
Article no.
DILMC7-10(24VDC)
277404
DILMC7-01(24VDC)
277436
DILMC9-10(24VDC)
277468
DILMC9-01(24VDC)
277500
DILMC12-10(24VDC)
277532
DILMC12-01(24VDC)
277564
DILMC15-10(24VDC)
293926
DILMC15-01(24VDC)
293961
DILMC17-10(RDC24)
277595
DILMC17-01(RDC24)
277625
DILMC25-10(RDC24)
277655
DILMC25-01(RDC24)
277685
DILMC32-10(RDC24)
277715
DILMC32-01(RDC24)
277745
DILMC40(RDC24)
277979
DILMC50(RDC24)
278009
DILMC65(RDC24)
278039
55
75
37
45
90
96
63
75
110
130
160
190
DILMC80(230V50HZ,240V60HZ)
239618
DILMC95(230V50HZ,240V60HZ)
239685
DILMC115(RAC240)
239736
DILMC150(RAC240)
239751
-
-
-
DILMC80(RDC24)
239652
DILMC95(RDC24)
239715
DILMC115(RDC24)
239741
DILMC150(RDC24)
239765
CA08103003Z_MOEM2015-EN.book Seite 157 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Contactors
Complete devices up to 170 A
Complete devices up to 170 A
DILM complete units
Screw terminals
3
4
5.5
7.5
11
15
Max. rating for three-phase motors, 50 - 60 Hz Rated operational current
AC-3
380 V 400 V 660 V 690 V
AC-1
Conventional free air thermal current,
3 pole, 50 - 60 Hz
Open at 40 °C
P kW
P kW
I th
=I e
A
AC operation
230 V 50 Hz, 240 V 60 Hz
Part no.
Article no.
3.5
4.5
6.5
11
14
17
22
22
22
40
45
45
DILM7-32(230V50HZ,240V60HZ)
276655
DILM9-32(230V50HZ,240V60HZ)
276795
DILM12-32(230V50HZ,240V60HZ)
276935
DILM17-32(230V50HZ,240V60HZ)
277100
DILM25-32(230V50HZ,240V60HZ)
277228
DILM32-32(230V50HZ,240V60HZ)
277356
18.5
22
30
23
30
35
60
80
98
DILM40-22(230V50HZ,240V60HZ)
277798
DILM50-22(230V50HZ,240V60HZ)
277862
DILM65-22(230V50HZ,240V60HZ)
277926
DC operation
24 V DC
Part no.
Article no.
DILM7-32(24VDC)
276670
DILM9-32(24VDC)
276810
DILM12-32(24VDC)
276950
DILM17-32(RDC24)
277114
DILM25-32(RDC24)
277242
DILM32-32(RDC24)
277370
DILM40-22(RDC24)
277812
DILM50-22(RDC24)
277876
DILM65-22(RDC24)
277940
55
75
37
45
90
96
63
75
110
130
160
190
DILM80-22(230V50HZ,240V60HZ)
239449
DILM95-22(230V50HZ,240V60HZ)
239527
DILM115-22(RAC240)
239578
DILM150-22(RAC240)
239598
DILM80-22(RDC24)
239463
DILM95-22(RDC24)
239541
DILM115-22(RDC24)
239581
DILM150-22(RDC24)
239601
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 157
CA08103003Z_MOEM2015-EN.book Seite 157 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Contactors
Complete devices up to 170 A
Complete devices up to 170 A
DILM complete units
Screw terminals
3
4
5.5
7.5
11
15
Max. rating for three-phase motors, 50 - 60 Hz Rated operational current
AC-3
380 V 400 V 660 V 690 V
AC-1
Conventional free air thermal current,
3 pole, 50 - 60 Hz
Open at 40 °C
P kW
P kW
I th
=I e
A
AC operation
230 V 50 Hz, 240 V 60 Hz
Part no.
Article no.
3.5
4.5
6.5
11
14
17
22
22
22
40
45
45
DILM7-32(230V50HZ,240V60HZ)
276655
DILM9-32(230V50HZ,240V60HZ)
276795
DILM12-32(230V50HZ,240V60HZ)
276935
DILM17-32(230V50HZ,240V60HZ)
277100
DILM25-32(230V50HZ,240V60HZ)
277228
DILM32-32(230V50HZ,240V60HZ)
277356
18.5
22
30
23
30
35
60
80
98
DILM40-22(230V50HZ,240V60HZ)
277798
DILM50-22(230V50HZ,240V60HZ)
277862
DILM65-22(230V50HZ,240V60HZ)
277926
DC operation
24 V DC
Part no.
Article no.
DILM7-32(24VDC)
276670
DILM9-32(24VDC)
276810
DILM12-32(24VDC)
276950
DILM17-32(RDC24)
277114
DILM25-32(RDC24)
277242
DILM32-32(RDC24)
277370
DILM40-22(RDC24)
277812
DILM50-22(RDC24)
277876
DILM65-22(RDC24)
277940
55
75
37
45
90
96
63
75
110
130
160
190
DILM80-22(230V50HZ,240V60HZ)
239449
DILM95-22(230V50HZ,240V60HZ)
239527
DILM115-22(RAC240)
239578
DILM150-22(RAC240)
239598
DILM80-22(RDC24)
239463
DILM95-22(RDC24)
239541
DILM115-22(RDC24)
239581
DILM150-22(RDC24)
239601
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Contactors and contactor relays
Basic devices with screw terminals
AC3
380 V
400 V
P kW
AC3
660 V
690 V
P kW
I
AC1 th
A
=I
*1 e
Part no.
Article No.
Part no.
Article No.
-
-
-
-
-
3
3
4
4
3
3
4
4
5.5
5.5
7.5
7.5
11
11
15
15
18.5
22
30
37
45
55
75
-
-
-
-
-
3
3
4
4
3.5
3.5
4.5
4.5
6.5
6.5
11
11
14
14
17
17
23
30
35
63
75
90
96
10
10
10
16
16
16
22
22
22
22
22
22
22
22
22
22
40
40
45
45
45
45
60
80
98
110
130
160
190
DILM12-01(230V50/60HZ)
276873
DILM17-10(230V50/60HZ)
277012
DILM17-01(230V50/60HZ)
277044
DILM25-10(230V50/60HZ)
277140
DILM25-01(230V50/60HZ)
277172
DILM32-10(230V50/60HZ)
277268
DILM32-01(230V50/60HZ)
277300
DILM40(230V50/60HZ)
277806
DILM50(230V50/60HZ)
277870
DILM65(230V50/60HZ)
277902
DILM80(230V50/60HZ)
239410
DILM95(230V50/60HZ)
239488
DILM115(RAC240)
239548
DILM150(RAC240)
239588
DILER-40(230V50/60HZ)
52725
DILER-31(230V50/60HZ)
52509
DILER-22(230V50/60HZ)
52508
DILA-40(230V50/60HZ)
276337
DILA-31(230V50/60HZ)
276372
DILA-22(230V50/60HZ)
276407
DILEEM-10(230V50/60HZ)
56674
DILEEM-01(230V50/60HZ)
58771
DILEM-10(230V50/60HZ)
52302
DILEM-01(230V50/60HZ)
51114
DILM7-10(230V50/60HZ)
276558
DILM7-01(230V50/60HZ)
276593
DILM9-10(230V50/60HZ)
276698
DILM9-01(230V50/60HZ)
276733
DILM12-10(230V50/60HZ)
276838
*1 Conventional thermal current, 3 pole, 50-60 Hz, open at 40 °C
RAC240≙190-240V 50/60Hz; RAC≙100-120V 50/60Hz; RAC≙42-48V 50/60Hz; RAC24≙24V 50/60Hz
For more contactors and coil voltages please look in our Online catalog: www.eaton.eu/ecat
DILM12-01(110V50/60HZ)
276871
DILM17-10(110V50/60HZ)
277010
DILM17-01(110V50/60HZ)
277042
DILM25-10(110V50/60HZ)
277138
DILM25-01(110V50/60HZ)
277170
DILM32-10(110V50/60HZ)
277266
DILM32-01(110V50/60HZ)
277298
DILM40(110V50/60HZ)
277772
DILM50(110V50/60HZ)
277836
DILM65(110V50/60HZ)
277900
DILM80(110V50/60HZ)
239408
DILM95(110V50/60HZ)
239486
DILM115(RAC120)
239547
DILM150(RAC120)
239587
DILER-40(110V50/60HZ)
21961
DILER-31(110V50/60HZ)
21624
DILER-22(110V50/60HZ)
21871
DILA-40(110V50/60HZ)
276335
DILA-31(110V50/60HZ)
276370
DILA-22(110V50/60HZ)
276405
DILEEM-10(110V50/60HZ)
51592
DILEEM-01(110V50/60HZ)
51618
DILEM-10(110V50/60HZ)
21455
DILEM-01(110V50/60HZ)
20436
DILM7-10(110V50/60HZ)
276556
DILM7-01(110V50/60HZ)
276591
DILM9-10(110V50/60HZ)
276696
DILM9-01(110V50/60HZ)
276731
DILM12-10(110V50/60HZ)
276836
158 EATON CA08103003Z-EN-INT
Part no.
Article No.
Part no.
Article No.
Moeller® series
DILM12-01(24V50/60HZ)
276869
DILM17-10(24V50/60HZ)
277008
DILM17-01(24V50/60HZ)
277040
DILM25-10(24V50/60HZ)
277136
DILM25-01(24V50/60HZ)
277168
DILM32-10(24V50/60HZ)
277264
DILM32-01(24V50/60HZ)
277296
DILM40(24V50/60HZ)
277770
DILM50(24V50/60HZ)
277834
DILM65(24V50/60HZ)
277898
DILM80(24V50/60HZ)
239406
DILM95(24V50/60HZ)
239484
DILM115(RAC24)
239545
DILM150(RAC24)
239585
DILER-40(24V50/60H)
21924
DILER-31(24V50/60HZ)
21594
DILER-22(24V50/60HZ)
21704
DILA-40(24V50/60HZ)
276333
DILA-31(24V50/60HZ)
276368
DILA-22(24V50/60HZ)
276403
DILEEM-10(24V50/60HZ)
51596
DILEEM-01(24V50/60HZ)
51621
DILEM-10(24V50/60HZ)
21417
DILEM-01(24V50/60HZ)
20402
DILM7-10(24V50/60HZ)
276554
DILM7-01(24V50/60HZ)
276589
DILM9-10(24V50/60HZ)
276694
DILM9-01(24V50/60HZ)
276729
DILM12-10(24V50/60HZ)
276834
DILM12-01(42V50HZ,48V60HZ)
276861
DILM17-10(42V50HZ,48V60HZ)
277000
DILM17-01(42V50HZ,48V60HZ)
277032
DILM25-10(42V50HZ,48V60HZ)
277128
DILM25-01(42V50HZ,48V60HZ)
277160
DILM32-10(42V50HZ,48V60HZ)
277256
DILM32-01(42V50HZ,48V60HZ)
277288
DILM40(42V50HZ,48V60HZ)
277762
DILM50(42V50HZ,48V60HZ)
277826
DILM65(42V50HZ,48V60HZ)
277890
DILM80(42V50HZ,48V60HZ)
239394
DILM95(42V50HZ,48V60HZ)
239476
DILM115(RAC48)
239546
DILM150(RAC48)
239586
DILER-40(42V50HZ,48V60HZ)
51755
DILER-31(42V50HZ,48V60HZ)
51764
DILER-22(42V50HZ,48V60HZ)
51773
DILA-40(42V50HZ,48V60HZ)
276325
DILA-31(42V50HZ,48V60HZ)
276360
DILA-22(42V50HZ,48V60HZ)
276395
DILEEM-10(42V50HZ,48V60HZ)
51612
DILEEM-01(42V50HZ,48V60HZ)
51637
DILEM-10(42V50HZ,48V60HZ)
51782
DILEM-01(42V50HZ,48V60HZ)
51791
DILM7-10(42V50HZ,48V60HZ)
276546
DILM7-01(42V50HZ,48V60HZ)
276581
DILM9-10(42V50HZ,48V60HZ)
276686
DILM9-01(42V50HZ,48V60HZ)
276721
DILM12-10(42V50HZ,48V60HZ)
276826
Complete assortment -> www.eaton.eu/ecat
Moeller® series
AC3
380 V
400 V
P kW
AC3
660 V
690 V
P kW
AC1
I
A th
=I
*1 e
Part no.
Article No.
Part no.
Article No.
-
-
-
-
-
3
4
4
3
3
4
4
5.5
22
30
37
45
-
-
-
-
-
3
4
4
3.5
3.5
4.5
4.5
6.5
30
35
63
75
10
10
10
16
16
16
22
22
22
22
22
22
22
22
80
98
110
130
-
-
DILER-40-C(230V50/60HZ)
231850
DILER-31-C(230V50/60HZ)
231827
DILER-22-C(230V50/60HZ)
231802
DILAC-40(230V50/60HZ)
276449
DILAC-31(230V50/60HZ)
276481
DILAC-22(230V50/60HZ)
276513
DILEEM-10-C(230V50/60HZ)
230049
DILEM-10-C(230V50/60HZ)
231667
DILEM-01-C(230V50/60HZ)
231690
DILMC7-10(230V50/60HZ)
277397
DILMC7-01(230V50/60HZ)
277429
DILMC9-10(230V50/60HZ)
277461
DILMC9-01(230V50/60HZ)
277493
DILMC12-10(230V50/60HZ)
277525
5.5
6.5
22
Spring-cage terminals on auxiliary and control circuit terminals
7.5
11 40 DILMC17-10(230V50/60HZ)
277589
7.5
11 40
DILMC12-01(230V50/60HZ)
277557
11 14 45
DILMC17-01(230V50/60HZ)
277619
DILMC25-10(230V50/60HZ)
277649
11 14 45
15
15
18.5
17
17
23
45
45
60
DILMC25-01(230V50/60HZ)
277679
DILMC32-10(230V50/60HZ)
277709
DILMC32-01(230V50/60HZ)
277739
DILMC40(230V50/60HZ)
277973
DILMC50(230V50/60HZ)
278003
DILMC65(230V50/60HZ)
278033
-
DILER-40-C(48V50HZ)
231835
DILER-31-C(48V50HZ)
231812
DILER-22-C(48V50HZ)
231787
DILAC-40(48V50HZ)
276432
DILAC-31(48V50HZ)
276464
DILAC-22(48V50HZ)
276496
DILEM-10-C(48V50HZ)
231652
DILEM-01-C(48V50HZ)
231675
DILMC7-10(48V50HZ)
277380
DILMC7-01(48V50HZ)
277412
DILMC9-10(48V50HZ)
277444
DILMC9-01(48V50HZ)
277476
DILMC12-10(48V50HZ)
277508
DILMC12-01(48V50HZ)
277540
DILMC17-10(48V50HZ)
277571
DILMC17-01(48V50HZ)
277601
DILMC25-10(48V50HZ)
277631
DILMC25-01(48V50HZ)
277661
DILMC32-10(48V50HZ)
277691
DILMC32-01(48V50HZ)
277721
DILMC40(48V50HZ)
277955
DILMC50(48V50HZ)
277985
DILMC65(48V50HZ)
278015
DILMC80(48V50HZ)
239606
DILMC95(48V50HZ)
239657
* 1 Conventional thermal current, 3 pole, 50-60 Hz, open at 40 °C
For more contactors and coil voltages please look in our Online catalog: www.eaton.eu/ecat
Contactors and contactor relays
Basic devices with spring-cage terminals
Part no.
Article No.
DILER-40-C(24V50/60HZ)
231847
DILER-31-C(24V50/60HZ)
231824
DILER-22-C(24V50/60HZ)
231799
-
DILAC-40(24V50/60HZ)
276445
DILAC-31(24V50/60HZ)
276477
DILAC-22(24V50/60HZ)
276509
DILEM-10-C(24V50/60HZ)
231664
DILEM-01-C(24V50/60HZ)
231687
DILMC7-10(24V50/60HZ)
277393
DILMC7-01(24V50/60HZ)
277425
DILMC9-10(24V50/60HZ)
277457
DILMC9-01(24V50/60HZ)
277489
DILMC12-10(24V50/60HZ)
277521
DILMC12-01(24V50/60HZ)
277553
-
-
-
-
DILMC17-10(24V50/60HZ)
277585
DILMC17-01(24V50/60HZ)
277615
DILMC25-10(24V50/60HZ)
277645
DILMC25-01(24V50/60HZ)
277675
DILMC32-10(24V50/60HZ)
277705
DILMC32-01(24V50/60HZ)
277735
DILMC40(24V50/60HZ)
277969
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT 159
CA08103003Z_MOEM2015-EN.book Seite 160 Donnerstag, 7. April 2016 12:02 12
Contactors
Comfort devices and standard devices greater than 170 A
Comfort devices and standard devices greater than 170 A
Comfort devices DILM
Screw connection
90
110
Max. rating for three-phase motors, 50 - 60 Hz
AC-3
380 V
400 V
660 V
690 V
P kW
P kW
Rated operational current
AC-1
Conventional free air thermal current,
3 pole, 50 - 60 Hz
Open at 40 °C
I th
=I e
A
AC operation
230 V 50 Hz, 240 V 60 Hz
Part no.
Article no.
140
150
337
386
DILM185A/22(RAC240)
139537
DILM225A/22(RAC240)
139547
Screw connection
250
315
355
400
450
560
132
160
200
800
980
1041
1102
1225
1225
430
490
612
344
560
630
720
750
1000
240
240
344
132
160
200
250
240
240
344
344
430
490
612
800
AC operation
110 V 50 Hz, 120 V 60 Hz
Part no.
Article no.
Moeller® series
DC operation
24 V DC
Part no.
Article no.
DILM185A/22(RAC120)
139536
DILM225A/22(RAC120)
139546
DILM185A/22(RDC24)
139540
DILM225A/22(RDC24)
139550
DILM250/22(RA250)
208201
DILM300A/22(RA250)
139556
DILM400/22(RA250)
208209
DILM500/22(RA250)
208213
DILM580/22(RA250)
208216
DILM650/22(RA250)
208219
DILM750/22(RA250)
208222
DILM820/22(RA250)
208225
DILM1000/22(RA250)
267214
-
DILM250/22(RA110)
208200
DILM300A/22(RA110)
139555
DILM400/22(RA110)
208208
DILM500/22(RA110)
208212
DILM580/22(RA110)
208215
DILM650/22(RA110)
208218
DILM750/22(RA110)
208221
DILM820/22(RA110)
208224
DILM250-S/22(220-240V50/60HZ)
274190
DILM300A-S/22(220-240V50/60HZ)
139559
DILM400-S/22(220-240V50/60HZ)
274196
DILM500-S/22(220-240V50/60HZ)
274199
DILM250-S/22(110-120V50/60HZ)
274189
DILM300A-S/22(110-120V50/60HZ)
139558
DILM400-S/22(110-120V50/60HZ)
274195
DILM500-S/22(110-120V50/60HZ)
274198
-
-
-
-
-
-
-
-
DILM250/22(RDC48)
208199
DILM300A/22(RDC48)
139554
-
DILM400/22(RDC48)
208207
DILM500/22(RDC48)
208211
CA08103003Z_MOEM2015-EN.book Seite 161 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Basic devices up to 200 A, 4 pole
Basic devices DILMP
Screw terminals
22
Rated operational current
AC-1
Conventional free air thermal current, 3 pole, 50 - 60 Hz
Open at 40 °C at 60 °C
I th
=I e
A
I th
A
=I e
AC operation
230 V 50 Hz, 240 V 60 Hz
Part no.
Article no.
20 DILMP20(230V50HZ,240V60HZ)
276970
Basic devices up to 200 A, 4 pole
AC operation
110 V 50 Hz, 120 V 60 Hz
Part no.
Article no.
Contactors
DC operation
24 V DC
Part no.
Article no.
DILMP20(110V50HZ,120V60HZ)
276967
DILMP20(24VDC)
276985
80
80
63
63
45
45
32
32
28
28
39
39
54
54
69
69
125
160
200
108
138
172
DILMP32-01(230V50HZ,240V60HZ)
118911
DILMP32-10(230V50HZ,240V60HZ)
109797
DILMP45-01(230V50HZ,240V60HZ)
118914
DILMP45-10(230V50HZ,240V60HZ)
109826
DILMP63(230V50HZ,240V60HZ)
109855
DILMP63(RAC240)
167512
DILMP80(230V50HZ,240V60HZ)
109884
DILMP80(RAC240)
167513
DILMP32-01(110V50HZ,120V60HZ)
118912
DILMP32-10(110V50HZ,120V60HZ)
109790
DILMP45-01(110V50HZ,120V60HZ)
118915
DILMP45-10(110V50HZ,120V60HZ)
109819
-
DILMP63(110V50HZ,120V60HZ)
109848
-
DILMP80(110V50HZ,120V60HZ)
109877
DILMP32-01(RDC24)
118913
DILMP32-10(RDC24)
109811
DILMP45-01(RDC24)
118916
DILMP45-10(RDC24)
109840
-
DILMP63(RDC24)
109869
-
DILMP80(RDC24)
109898
DILMP125(RAC240)
109905
DILMP160(RAC240)
109915
DILMP200(RAC240)
109925
DILMP125(RAC120)
109903
DILMP160(RAC120)
109913
DILMP200(RAC120)
109923
DILMP125(RDC24)
109910
DILMP160(RDC24)
109920
DILMP200(RDC24)
109930
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 161
CA08103003Z_MOEM2015-EN.book Seite 161 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Basic devices up to 200 A, 4 pole
Basic devices DILMP
Screw terminals
22
Rated operational current
AC-1
Conventional free air thermal current, 3 pole, 50 - 60 Hz
Open at 40 °C at 60 °C
I th
=I e
A
I th
A
=I e
AC operation
230 V 50 Hz, 240 V 60 Hz
Part no.
Article no.
20 DILMP20(230V50HZ,240V60HZ)
276970
Basic devices up to 200 A, 4 pole
AC operation
110 V 50 Hz, 120 V 60 Hz
Part no.
Article no.
Contactors
DC operation
24 V DC
Part no.
Article no.
DILMP20(110V50HZ,120V60HZ)
276967
DILMP20(24VDC)
276985
80
80
63
63
45
45
32
32
28
28
39
39
54
54
69
69
125
160
200
108
138
172
DILMP32-01(230V50HZ,240V60HZ)
118911
DILMP32-10(230V50HZ,240V60HZ)
109797
DILMP45-01(230V50HZ,240V60HZ)
118914
DILMP45-10(230V50HZ,240V60HZ)
109826
DILMP63(230V50HZ,240V60HZ)
109855
DILMP63(RAC240)
167512
DILMP80(230V50HZ,240V60HZ)
109884
DILMP80(RAC240)
167513
DILMP32-01(110V50HZ,120V60HZ)
118912
DILMP32-10(110V50HZ,120V60HZ)
109790
DILMP45-01(110V50HZ,120V60HZ)
118915
DILMP45-10(110V50HZ,120V60HZ)
109819
-
DILMP63(110V50HZ,120V60HZ)
109848
-
DILMP80(110V50HZ,120V60HZ)
109877
DILMP32-01(RDC24)
118913
DILMP32-10(RDC24)
109811
DILMP45-01(RDC24)
118916
DILMP45-10(RDC24)
109840
-
DILMP63(RDC24)
109869
-
DILMP80(RDC24)
109898
DILMP125(RAC240)
109905
DILMP160(RAC240)
109915
DILMP200(RAC240)
109925
DILMP125(RAC120)
109903
DILMP160(RAC120)
109913
DILMP200(RAC120)
109923
DILMP125(RDC24)
109910
DILMP160(RDC24)
109920
DILMP200(RDC24)
109930
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 162 Donnerstag, 7. April 2016 12:02 12
Contactors
Contactors for capacitors, Lighting contactors
Contactors for capacitors, Lighting contactors
DILK contactors for capacitors
With series resistors
Basic Units
7.5
11
Rated power of three-phase capacitors
50 - 60 Hz
Open
230 V 400 V 525 V kVAr kVAr kVAr
12.5
20
16.7
25
15
20
25
25
33.3
50
33.3
40
65
690 V kVAr
40
55
20
33.3
85
Contact sequence
A1
A2
1 3 5 13 21
2 4 6 14 22
A1
A2
1 3 5 13
2 4 6 14
Part no.
Article no.
Moeller® series
DILK12-11(230V50HZ,240V60HZ)
293988
DILK20-11(230V50HZ,240V60HZ)
294010
DILK25-11(230V50HZ,240V60HZ)
294032
DILK33-10(230V50HZ,240V60HZ)
294054
DILK50-10(230V50HZ,240V60HZ)
294076
Lighting contactors DILL
12
18
20
Rated operational current
AC-5a AC-5b
Conventional free air thermal current, 3 pole,
50 - 60 Hz AC-1 at 60 °C
220 V 230 V 380 V 400 V 220 V 230 V 380 V 400 V Open
I e
A
I e
A
I e
A
I e
A
I th
A
= I e
Part no.
Article no.
12
18
20
14
21
27
14
21
27
24
35
40
DILL12(230V50HZ,240V60HZ)
104402
DILL18(230V50HZ,240V60HZ)
104405
DILL20(230V50HZ,240V60HZ)
104408
Switchgear for lighting systems
DIL
Permissible compensation capacitance C max
L12
[mF] 470
Filament lamp
Mercury blended lamps
Fluorescent lamps, conventional
-reactor – starter – connection
Fluorescent lamps, duo circuit
(series compensated)
Electronic upstream devices
High-pressure mercury-arc lamps
Metal-halide lamps
High-pressure sodium lamps
Low-pressure sodium lamps
I e
I e
I e
[A]
[A]
[A]
I e
[A]
[A]
[A]
[A]
[A]
[A]
I e
I e
I e
I e
I e
12
12
12
12
7.5
14
12
20
20
L18
470
21
16
26
26
18
18
18
18
10
L20
470
27
23
35
35
20
20
20
20
12
5
6
9
M7
47
5.5
3
5
3.5
3.5
3.5
8
M9
80
7.5
6.5
10
4
6
6
6
6.5
M12
100
10
8.5
15
13
6
8.5
10
10
10
M17
220
14
12
20
15
12
12
12
12
7.5
DIL M65
Permissible compensation capacitance C max
[mF] 500
Filament lamp
Mercury blended lamps
Fluorescent lamps, conventional
-reactor – starter – connection
Fluorescent lamps, duo circuit (series compensated)
Electronic upstream devices
I
I
I
I e e e e
[A]
[A]
[A]
[A]
I e
[A]
High-pressure mercury vapor lamps I e
Metal-halide lamps
High-pressure sodium lamps
Low-pressure sodium lamps
I e
I e
I e
[A]
[A]
[A]
[A]
55
45
55
59
45.5
36
36
36
25
M80
550
67
65
95
71
56
55
55
55
35
M95
620
79
67
100
95
66.5
60
60
60
40
M115 M150 M185A M225A M250
830 970 2055 2300 2600
95
80
125
100
80.5
80
80
80
50
125
110
145
138
105
95
95
95
70
153
123
207
186
130
138
138
138
100
187
150
237
213
158
158
158
158
111
208
167
263
236
175
175
175
175
123
In compensated lamps, the sum of the capacitances must not exceed the contactors' max. permissible capacitor load (C max
The values in the table are for each contact in the contactors.
)!
M25
330
21
16
26
22.5
17.5
17.5
17.5
17.5
10
EATON CA08103003Z-EN-INT
M32
470
27
23
35
29
22.5
20
20
20
12
270
210
200
200
200
140
M300A M400
3000 3250
249
200
300
332
266
375
338
280
250
250
250
175
M40
470
33
30
41
36
28
25
25
25
15
Complete assortment -> www.eaton.eu/ecat
M50
500
42
38
45
47
35
30
30
30
22
473
350
350
350
350
245
M500
3500
415
332
525
CA08103003Z_MOEM2015-EN.book Seite 163 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Contactors
Star-delta starter combinations
Star-delta starter combinations
Rated operational current
AC-3 e
A
I
380 V 400 V
Star-delta combinations SDAINL
Operating frequency: maximum 30 starts per hour
12
30
45
16
22
55
70
90
115
18.5
22
30
140
165
200
260
37
45
55
75
Components for self-assembly of star-delta combinations
Max. motor rating for three-phase motors 50 – 60 Hz
AC-3 Changeover time 1)
7.5
11
15
3
4
5.5
230 V 400 V 500 V 690 V 1000 V kW kW kW kW kW
90 160 200 250 132 up to
12 s
●
Max. rating for three-phase motors, 50 - 60 Hz up to
20 s
●
AC-3
220 V 230 V 380 V 400 V 500 V
P kW
P kW
P kW up to
30 s
●
15
22
30
5.5
7.5
11
75
90
110
132
37
45
55
18.5
30
37
5.5
7.5
11
90
110
132
160
45
55
75
37
45
55
660 V 690 V
P kW
18.5
22
30
5.5
7.5
11
90
132
160
160
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
Max. changeover time s
Individual components of the combination
Part no.
Article no.
Coil in accordance with 50005
Contacts EN 50005 and EN 50012
Mains contactor
Delta contactor
Star contactor
Timing relay
K1
Q11 Q15 Q13
Part no. DIL Part no. DIL Part no. DIL Part no.
M185A/22 M185A/22 M115/22 ETR4-51
SDAINLM12(230V50HZ,240V60HZ)
278286
SDAINLM16(230V50HZ,240V60HZ)
278311
SDAINLM22(230V50HZ,240V60HZ)
278336
SDAINLM30(230V50HZ,240V60HZ)
278361
SDAINLM45(230V50HZ,240V60HZ)
278386
SDAINLM55(230V50HZ,240V60HZ)
278411
SDAINLM70(230V50HZ,240V60HZ)
239895
SDAINLM90(230V50HZ,240V60HZ)
239937
SDAINLM115(230V50HZ,240V60HZ)
239963
SDAINLM140(230V50HZ,240V60HZ)
240009
SDAINLM165(230V50HZ,240V60HZ)
240035
SDAINLM200(230V50HZ,240V60HZ)
101010
SDAINLM260(230V50HZ,240V60HZ)
101031
Spare auxiliary contacts
Q11
21 31
Q15
31 43
Q13
31 43
110 200 250 315 160 ● ● – M225A/22 M225A/22 M150/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
132 250 315 400 200 ● ● ● M250/22 M250/22 M185A/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
160 300 355 450 200 ● ● ● M300A/22 M300A/22 M185A/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
200 355 450 560 220 ● ● – M400/22 M400/22 M250/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
250 450 560 600 220 ● ● ● M500/22 M500/22 M300A/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
300 560 710 900 355 ● ● ● M580/22 M580/22 M400/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
350 630 750 950 355 ● ● ● M650/22 M650/22 M400/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
400 710 900 1200 1400 ● ● ● M750/22 M750/22 M580/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
450 800 950 1300 1400 ● ● ● M820/22 M820/22 M580/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
560 1000 1200 1700 1700 ● ● – M1000/22 M1000/22 M650/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
22 32 32 44 32 44
Notes 1) Longer changeover times please enquire
EATON CORPORATION CA08103003Z-EN 163
CA08103003Z_MOEM2015-EN.book Seite 163 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Contactors
Star-delta starter combinations
Star-delta starter combinations
Rated operational current
AC-3 e
A
I
380 V 400 V
Star-delta combinations SDAINL
Operating frequency: maximum 30 starts per hour
12
30
45
16
22
55
70
90
115
18.5
22
30
140
165
200
260
37
45
55
75
Components for self-assembly of star-delta combinations
Max. motor rating for three-phase motors 50 – 60 Hz
AC-3 Changeover time 1)
7.5
11
15
3
4
5.5
230 V 400 V 500 V 690 V 1000 V kW kW kW kW kW
90 160 200 250 132 up to
12 s
●
Max. rating for three-phase motors, 50 - 60 Hz up to
20 s
●
AC-3
220 V 230 V 380 V 400 V 500 V
P kW
P kW
P kW up to
30 s
●
15
22
30
5.5
7.5
11
75
90
110
132
37
45
55
18.5
30
37
5.5
7.5
11
90
110
132
160
45
55
75
37
45
55
660 V 690 V
P kW
18.5
22
30
5.5
7.5
11
90
132
160
160
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
< 20
Max. changeover time s
Individual components of the combination
Part no.
Article no.
Coil in accordance with 50005
Contacts EN 50005 and EN 50012
Mains contactor
Delta contactor
Q11 Q15
Part no. DIL Part no. DIL
Star contactor
Timing relay
K1
Q13
Part no. DIL Part no.
M185A/22 M185A/22 M115/22 ETR4-51
SDAINLM12(230V50HZ,240V60HZ)
278286
SDAINLM16(230V50HZ,240V60HZ)
278311
SDAINLM22(230V50HZ,240V60HZ)
278336
SDAINLM30(230V50HZ,240V60HZ)
278361
SDAINLM45(230V50HZ,240V60HZ)
278386
SDAINLM55(230V50HZ,240V60HZ)
278411
SDAINLM70(230V50HZ,240V60HZ)
239895
SDAINLM90(230V50HZ,240V60HZ)
239937
SDAINLM115(230V50HZ,240V60HZ)
239963
SDAINLM140(230V50HZ,240V60HZ)
240009
SDAINLM165(230V50HZ,240V60HZ)
240035
SDAINLM200(230V50HZ,240V60HZ)
101010
SDAINLM260(230V50HZ,240V60HZ)
101031
Spare auxiliary contacts
Q11
21 31
Q15
31 43
Q13
31 43
110 200 250 315 160 ● ● – M225A/22 M225A/22 M150/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
132 250 315 400 200 ● ● ● M250/22 M250/22 M185A/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
160 300 355 450 200 ● ● ● M300A/22 M300A/22 M185A/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
200 355 450 560 220 ● ● – M400/22 M400/22 M250/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
250 450 560 600 220 ● ● ● M500/22 M500/22 M300A/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
300 560 710 900 355 ● ● ● M580/22 M580/22 M400/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
350 630 750 950 355 ● ● ● M650/22 M650/22 M400/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
400 710 900 1200 1400 ● ● ● M750/22 M750/22 M580/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
450 800 950 1300 1400 ● ● ● M820/22 M820/22 M580/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
560 1000 1200 1700 1700 ● ● – M1000/22 M1000/22 M650/22 ETR4-51
22 32
21 31
32 44
31 43
32 44
31 43
22 32 32 44 32 44
Notes 1) Longer changeover times please enquire
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 164 Donnerstag, 7. April 2016 12:02 12
Contactors
Reversing combinations Moeller® series
Reversing combinations
DIUL reversing combinations
AC operation
9
Rated operational current
AC-3 e
A
I
380 V 400 V
9
2.2
2.2
Max. rating for three-phase motors, 50 - 60 Hz
AC-3 AC-4
220 V 230 V 380 V 400 V 660 V 690 V 220 V 230 V 380 V 400 V 660 V 690 V
P kW
P kW
P kW
P kW
P kW
P kW
Part no.
Article no.
4
4
4
4
1.5
1.5
3
3
3
3
DIULEM/21/MV(230V50HZ,240V60HZ)
051849
DIULEM/21/MV-G(24VDC)
214655
25
25
32
18
18
12
12
9
9
7
7
50
65
32
40
7.5
7.5
10
5
5
3.5
3.5
2.5
2.5
2.2
2.2
10
12.5
15.5
20
11
11
15
7.5
7.5
5.5
5.5
4
4
3
3
22
30
15
18.5
14
14
17
11
11
6.5
6.5
3.5
3.5
4.5
4.5
30
35
17
23
3.5
3.5
4
2.5
2.5
2
2
1.5
1.5
1
1
6
7
4
5
6
6
7
4.5
4.5
3
3
2.5
2.5
2.2
2.2
10
12
7
9
8.5
8.5
10
4.4
4.4
6.5
6.5
2.9
2.9
3.6
3.6
14
17
10
12
DIULM7/21(230V50HZ,240V60HZ)
278061
DIULM7/21(24VDC) 2)
107021
DIULM9/21(230V50HZ,240V60HZ)
278086
DIULM9/21(24VDC)
107022
DIULM12/21(230V50HZ,240V60HZ)
278111
DIULM12/21(24VDC)
107023
DIULM17/21(230V50HZ,240V60HZ)
278136
DIULM17/21(RDC24)
107024
DIULM25/21(230V50HZ,240V60HZ)
278161
DIULM25/21(RDC24)
107025
DIULM32/21(230V50HZ,240V60HZ)
278186
DIULM32/21(RDC24)
107026
DIULM40/11(230V50HZ,240V60HZ)
278211
DIULM50/11(230V50HZ,240V60HZ)
278236
DIULM65/11(230V50HZ,240V60HZ)
278261
CA08103003Z_MOEM2015-EN.book Seite 165 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Contactors
SmartWire-DT® module, Auxiliary contact modules
SmartWire-DT® module, Auxiliary contact modules
Contacts
N/O = Normally open
N/O
E
: NO early-make
N/C = Normally closed
NC
L
=NC late-break
SmartWire-DT protective modules
For connecting the contactors to SmartWire-DT
Per contactor 1 module necessary.
Messages Switch status Contactor, status of the digital inputs 1 and 2
Commands Contactor actuation
Messages Contactor switching position, status of the digital inputs 1 and 2, 1-0-A switch position
Commands Contactor actuation
For use with
DILM(C)7… - DILM(C)32
DILM38
DILA
MSC-D(E)-...(24VDC)
Auxiliary contact modules
With interlocked opposing contacts, except for …XHI(C)V
Top mounting auxiliary contacts
Screw terminals 1 N/O
-
1 NC
2 NC
2 N/O
3 N/O
2 NC
1 NC
DILM(C)7-10…
DILM(C)9-10…
DILM(C)12-10…
DILM(C)15-10…
DILM(C)17-10…
DILM(C)25-10…
DILM(C)32-10…
DILM38-10…
DILMP20…
DILMP32-10…
DILMP45-10…
Part no.
DIL-SWD-32-001
DIL-SWD-32-002
DILM32-XHI11
DILM32-XHI02
DILM32-XHI22
DILM32-XHI31
Article no.
118560
118561
277376
277375
277377
106112
Spring-loaded terminals
-
1 N/O 1 NC
2 NC
DILM32-XHIC11
DILM32-XHIC02
277751
277750
2 N/O 2 NC DILM32-XHIC22 277752
Screw terminals 2 N/O
1 N/O
-
1 N/O
E
4 N/O
3 N/O
2 N/O
1 N/O
-
1 N/O
1 N/O
E
-
1 NC
2 NC
1 NC
L
-
1 NC
2 NC
3 NC
4 NC
1 NC
1 NC
L
DILA…
DILM(C)7…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILM(C)17…
DILM(C)25…
DILM(C)32…
DILM38…
DILMP20…
DILMP32…
DILMP45…
DILA-XHI20
DILA-XHI11
DILA-XHI02
DILA-XHIV11
DILA-XHI40
DILA-XHI31
DILA-XHI22
DILA-XHI13
DILA-XHI04
DILA-XHIV22
276422
276421
276420
276423
276428
276427
276426
276425
276424
276429
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 165
CA08103003Z_MOEM2015-EN.book Seite 165 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Contactors
SmartWire-DT® module, Auxiliary contact modules
SmartWire-DT® module, Auxiliary contact modules
Contacts
N/O = Normally open
N/O
E
: NO early-make
N/C = Normally closed
NC
L
=NC late-break
SmartWire-DT protective modules
For connecting the contactors to SmartWire-DT
Per contactor 1 module necessary.
Messages Switch status Contactor, status of the digital inputs 1 and 2
Commands Contactor actuation
Messages Contactor switching position, status of the digital inputs 1 and 2, 1-0-A switch position
Commands Contactor actuation
For use with
DILM(C)7… - DILM(C)32
DILM38
DILA
MSC-D(E)-...(24VDC)
Auxiliary contact modules
With interlocked opposing contacts, except for …XHI(C)V
Top mounting auxiliary contacts
Screw terminals 1 N/O
-
1 NC
2 NC
2 N/O
3 N/O
2 NC
1 NC
DILM(C)7-10…
DILM(C)9-10…
DILM(C)12-10…
DILM(C)15-10…
DILM(C)17-10…
DILM(C)25-10…
DILM(C)32-10…
DILM38-10…
DILMP20…
DILMP32-10…
DILMP45-10…
Part no.
DIL-SWD-32-001
DIL-SWD-32-002
DILM32-XHI11
DILM32-XHI02
DILM32-XHI22
DILM32-XHI31
Article no.
118560
118561
277376
277375
277377
106112
Spring-loaded terminals
-
1 N/O 1 NC
2 NC
DILM32-XHIC11
DILM32-XHIC02
277751
277750
2 N/O 2 NC DILM32-XHIC22 277752
Screw terminals 2 N/O
1 N/O
-
1 N/O
E
4 N/O
3 N/O
2 N/O
1 N/O
-
1 N/O
1 N/O
E
-
1 NC
2 NC
1 NC
L
-
1 NC
2 NC
3 NC
4 NC
1 NC
1 NC
L
DILA…
DILM(C)7…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILM(C)17…
DILM(C)25…
DILM(C)32…
DILM38…
DILMP20…
DILMP32…
DILMP45…
DILA-XHI20
DILA-XHI11
DILA-XHI02
DILA-XHIV11
DILA-XHI40
DILA-XHI31
DILA-XHI22
DILA-XHI13
DILA-XHI04
DILA-XHIV22
276422
276421
276420
276423
276428
276427
276426
276425
276424
276429
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 166 Donnerstag, 7. April 2016 12:02 12
Contactors
Auxiliary contact modules
Auxiliary contact modules
Contacts
N/O = Normally open
N/O
E
: NO early-make
N/C = Normally closed
NC
L
=NC late-break
Auxiliary contact modules
With interlocked opposing contacts, except for …XHI(C)V
Top mounting auxiliary contacts
Screw terminals 1 N/O (for electronic applications)
1 NC (for electronic applications)
2 N/O (1 N/O above microswitch for electronic applications)
2 NC (1 NC above microswitch for electronic applications)
For use with
DILA…
DILM(C)7…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILM(C)17…
DILM(C)25…
DILM(C)32…
DILM38…
DILMP20…
DILMP32…
DILMP45…
Spring-loaded terminals 2 N/O
1 N/O
-
1 N/O
E
-
1 NC
2 NC
1 NC
L
Screw terminals 2 N/O
-
1 N/O
1 N/O
4 N/O
3 N/O
2 N/O
2 N/O
1 N/O
-
1 N/O
1 N/O
E
4 N/O
3 N/O
-
2 N/O
1 N/O
1 N/O
1 N/O
E
-
1 NC
1 NC
2 NC
-
1 NC
2 NC
2 NC
3 NC
4 NC
1 NC
1 NC
L
-
1 NC
2 NC
3 NC
4 NC
1 NC
1 NC
L
DILA…
DILM(C)7…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILM(C)17…
DILM(C)25…
DILM(C)32…
DILM38…
DILMP20…
DILMP32…
DILMP45…
DILM40…
DILM50…
DILM65…
DILM72…
DILM80…
DILM95…
DILM115…
DILM150…
DILM170…
DILMP63…
DILMP80…
DILMP125…
DILMP160…
DILMP200…
Part no.
DILA-XHIR11 110140
DILA-XHIR22
DILA-XHIC20
DILA-XHIC11
DILA-XHIC02
DILA-XHICV11
DILA-XHIC40
DILA-XHIC31
DILA-XHIC22
DILA-XHIC13
DILA-XHIC04
DILA-XHICV22
DILM150-XHI20
DILM150-XHI11
DILM150-XHIA11
DILM150-XHI02
DILM150-XHI40
DILM150-XHI31
DILM150-XHI22
DILM150-XHIA22
DILM150-XHI13
DILM150-XHI04
DILM150-XHIV22
139580
276528
276527
276526
276529
276534
276533
276532
276531
276530
276535
277945
277946
283463
277947
277948
277949
277950
283464
277951
277952
277953
Moeller® series
Article no.
CA08103003Z_MOEM2015-EN.book Seite 167 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Contacts
N/O = Normally open
N/O
E
: NO early-make
N/C = Normally closed
NC
L
=NC late-break
Auxiliary contact modules
With interlocked opposing contacts, except for …XHI(C)V
Side-mounting auxiliary contact
Screw terminals
-
1 N/O -
1 NC
1 N/O
1 N/O
1 N/O
1 N/O
E
1 N/O
1 N/O
E
1 N/O
Spring-loaded terminals 1 N/O
1 NC
-
1 NC
1 NC
1 NC
L
1 NC
1 NC
1 NC
L
For use with
DILM7…
DILM9…
DILM12…
DILM15…
DILMP20…
DILA…
DILM17…
DILM25…
DILM32…
DILM38…
DILM250 - DILH2600
DILM40 - DILM225A
DILMP63 - DILMP200
DILMC7…
DILMC9…
DILMC12…
DILMC15…
DILAC…
1 NC
Part no.
Contactors
Auxiliary contact modules
Article no.
DILA-XHI10-S
DILA-XHI01-S
115948
115949
DILM32-XHI11-S
DILM820-XHI11-SI
DILM820-XHI11-SA
DILM820-XHI11V-SI
DILM1000-XHI11-SI
DILM1000-XHIV11-SI
DILM1000-XHI11-SA
DILA-XHIC10-S
101371
208281
208282
208283
278425
278426
278427
115950
DILA-XHIC01-S 115951
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 167
CA08103003Z_MOEM2015-EN.book Seite 167 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Contacts
N/O = Normally open
N/O
E
: NO early-make
N/C = Normally closed
NC
L
=NC late-break
Auxiliary contact modules
With interlocked opposing contacts, except for …XHI(C)V
Side-mounting auxiliary contact
Screw terminals
-
1 N/O -
1 NC
1 N/O
1 N/O
1 N/O
1 N/O
E
1 N/O
1 N/O
E
1 N/O
Spring-loaded terminals 1 N/O
1 NC
-
1 NC
1 NC
1 NC
L
1 NC
1 NC
1 NC
L
For use with
DILM7…
DILM9…
DILM12…
DILM15…
DILMP20…
DILA…
DILM17…
DILM25…
DILM32…
DILM38…
DILM250 - DILH2600
DILM40 - DILM225A
DILMP63 - DILMP200
DILMC7…
DILMC9…
DILMC12…
DILMC15…
DILAC…
1 NC
Part no.
Contactors
Auxiliary contact modules
Article no.
DILA-XHI10-S
DILA-XHI01-S
115948
115949
DILM32-XHI11-S
DILM820-XHI11-SI
DILM820-XHI11-SA
DILM820-XHI11V-SI
DILM1000-XHI11-SI
DILM1000-XHIV11-SI
DILM1000-XHI11-SA
DILA-XHIC10-S
101371
208281
208282
208283
278425
278426
278427
115950
DILA-XHIC01-S 115951
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 168 Donnerstag, 7. April 2016 12:02 12
Contactors
Suppressors
Suppressors
For use with
Suppressors
RC suppressors
DILM7 - DILM15
DILMP20
DILA
DILM17 - DILM32
DILMP32 - DILMP45
DILM40 - DILM95
DILMP63 - DILMP200
Varistor suppressors
DILM7 - DILM15
DILMP20
DILA
DILM17 - DILM32
DILMP32 - DILMP45
DILM40 - DILM95
DILMP63 - DILMP200
Varistor suppressors with integrated LED
DILM7 - DILM12
DILMP20
DILA
DILM17 - DILM32
DILMP32 - DILMP45
DILM40 - DILM95
DILMP63 - DILMP200
Free-wheel diode suppressor
DILM7 - DILM15
DILMP20
DILA
AC operation
230 V 50 Hz, 240 V 60 Hz
Part no.
Article no.
AC operation
110 V 50 Hz, 120 V 60 Hz
Part no.
Article no.
Moeller® series
DC operation
24 V DC
Part no.
Article no.
DILM12-XSPR240
281200
DILM32-XSPR240
281203
DILM95-XSPR240
281206
-
DILM12-XSPV240
281210
DILM32-XSPV240
281214
DILM95-XSPV240
281218
DILM12-XSPVL240
281221
DILM32-XSPVL240
281223
DILM95-XSPVL240
281225
DILM12-XSPR240
281200
DILM32-XSPR240
281203
DILM95-XSPR240
281206
-
DILM12-XSPV130
281209
DILM32-XSPV130
281213
DILM95-XSPV130
281217
DILM12-XSPVL240
281221
DILM32-XSPVL240
281223
DILM95-XSPVL240
281225
-
-
-
-
-
-
-
-
-
DILM12-XSPD
101672
CA08103003Z_MOEM2015-EN.book Seite 169 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Accessories
Mechanical interlock
Paralleling links for main contacts
Consisting of 2 paralleling links
Star-point bridges
DILM40 - DILM72
DILM80 - DILM170
DILM185A
DILM7 - DILM15
DILM17 - DILM32
DILM40 - DILM72
DILM80 - DILM170
DILM185A - DILM400
DILM500
For use with
DILM7 - DILM15
DILMP20
DILA
DILM17 - DILM38
DILMP32 - DILMP45
DILM40 - DILM72
DILMP63 - DILMP80
DILM80 - DILM170
DILMP125 - DILMP200
DILM185A, DILM225A,
DILM250, DILM300A,
DILM400, DILM500,
DILM580, DILM650
DILM750, DILM820
DILM1000
DILM7 - DILM15
DILM17 - DILM32
DILM12-XP1
281193
DILM32-XP1
281194
DILM65-XP1
281195
DILM150-XP1
284769
DILM185-XP1
208292
DILM12-XS1
281190
DILM32-XS1
281191
DILM65-XS1
281192
DILM150-XS1
284768
DILM400-XS1
208291
DILM500-XS1
208290
Part no.
Article no.
DILM12-XMV
281196
DILM32-XMV
281197
DILM65-XMV
281198
DILM150-XMV
240081
DILM500-XMV
208289
DILM820-XMV
208288
Contactors
Accessories
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 169
CA08103003Z_MOEM2015-EN.book Seite 169 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Accessories
Mechanical interlock
Paralleling links for main contacts
Consisting of 2 paralleling links
Star-point bridges
DILM40 - DILM72
DILM80 - DILM170
DILM185A
DILM7 - DILM15
DILM17 - DILM32
DILM40 - DILM72
DILM80 - DILM170
DILM185A - DILM400
DILM500
For use with
DILM7 - DILM15
DILMP20
DILA
DILM17 - DILM38
DILMP32 - DILMP45
DILM40 - DILM72
DILMP63 - DILMP80
DILM80 - DILM170
DILMP125 - DILMP200
DILM185A, DILM225A,
DILM250, DILM300A,
DILM400, DILM500,
DILM580, DILM650
DILM750, DILM820
DILM1000
DILM7 - DILM15
DILM17 - DILM32
DILM12-XP1
281193
DILM32-XP1
281194
DILM65-XP1
281195
DILM150-XP1
284769
DILM185-XP1
208292
DILM12-XS1
281190
DILM32-XS1
281191
DILM65-XS1
281192
DILM150-XS1
284768
DILM400-XS1
208291
DILM500-XS1
208290
Part no.
Article no.
DILM12-XMV
281196
DILM32-XMV
281197
DILM65-XMV
281198
DILM150-XMV
240081
DILM500-XMV
208289
DILM820-XMV
208288
Contactors
Accessories
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 170 Donnerstag, 7. April 2016 12:02 12
Contactors
Accessories
For use with
Star-delta wiring kit Including star-point bridge
Main current wiring for star-delta combination
DILM7/9/12/15 mains contactor
DILM7/9/12/15 delta contactor
DILM7/9/12/15 star contactor
DILM17/25/32 mains contactor
DILM17/25/32 delta contactor
DILM17/25/32 star contactor
DILM40/50/65 mains contactor
DILM40/50/65 delta contactor
DILM40/50/65 star contactor
Reversing wiring kits
Main current wiring for reversing combinations
DILM7
DILM9
DILM12
DILM17
DILM25
DILM32
DILM40
DILM50
DILM65
IP2X cover
DILM17
DILM25
DILM32
DILM38
DILMP32
DILMP45
DILM40
DILM50
DILM65
DILM72
DILMP63
DILMP80
DILM80
DILM95
DILM115
DILM150
DILM170
DILMP125
DILMP160
DILMP200
ZB150
Covers
DILM185A
DILM225A
Z5-… FF225A
DILM250
DILM300A
DILM400
DILM500
DILM570
DILM580
DILM650
DILM750
DILM820, DILM1000
Cable terminal block
With control cable connection consisting of 3 box terminals
Connection options: round conductors, flexible and stranded, ribbon cables.
DILM185A
DILM225A
DILM250
DILM300A
DILM400
DILM225A-XHB
139560
DILM400-XHB
208287
DILM500-XHB
208286
DILM650-XHB
208285
DILM820-XHB
208284
DILM225A-XKU-S
139561
DILM400-XKU-S
208293
Part no.
Article no.
DILM12-XSL
283130
DILM32-XSL
283131
DILM65-XSL
101058
DILM12-XRL
283108
DILM32-XRL
283109
DILM65-XRL
101057
DILM32-XIP2X
118855
DILM65-XIP2X
106491
DILM150-XIP2X
106492
Moeller® series
CA08103003Z_MOEM2015-EN.book Seite 171 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Bimetal Overload Relay
Overload relays
Bimetal Overload Relay
I r
A
Setting range
Overload releases
For use with
DILEM
Part no.
DILM7 - DILM15
Article no.
Part no.
Article no.
DILM17 - DILM38
Part no.
Article no.
DILM40 - DILM72
Part no.
Article no.
DILM80 - DILM170
Part no.
Article no.
Overload relay ZE, ZB
0.1 - 0.16
0.16 - 0.24
0.24 - 0.4
ZE-0,16
ZE-0,24
ZE-0,4
9 - 12
10 - 16
12 - 16
16 - 24
24 - 32
24 - 40
32 - 38
35 - 50
0.4 - 0.6
0.6 - 1
1 - 1.6
1.6 - 2.4
2.4 - 4
4 - 6
6 - 9
6 - 10
40 - 57
50 - 65
50 - 70
65 - 75
70 - 100
95 - 125
120 - 150
145 - 175
ZE-0,6
ZE-1,0
ZE-1,6
-
-
-
-
-
-
-
-
ZE-12
-
-
-
-
-
-
-
-
ZE-2,4
ZE-4
ZE-6
ZE-9
-
-
-
-
-
-
-
-
-
-
-
-
014518
014565
-
014708
-
-
-
014752
014263
014285
014300
014333
014376
014432
014479
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZB12-0,16 278431
ZB12-0,24 278432
ZB12-0,4 278433
ZB12-0,6
ZB12-1
ZB12-1,6
ZB12-2,4
ZB12-4
278434
278435
278436
278437
ZB12-6
ZB12-10
ZB12-12
278438
278439
-
278440
ZB12-16
-
278441
-
290168
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZB32-0,16 278442
ZB32-0,24 278443
ZB32-0,4 278444
ZB32-0,6
ZB32-1
ZB32-1,6
ZB32-2,4
ZB32-4
278445
278446
278447
278448
ZB32-6
ZB32-10
278449
278450
-
278451
ZB32-24
ZB32-32
ZB32-38
-
-
-
278453
-
278454
-
112474
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZB65-10
-
ZB65-16
-
ZB65-24
-
-
-
ZB65-40
ZB65-57
ZB65-65
-
-
-
-
ZB65-75
-
-
-
278455
-
278456
-
278457
-
-
-
-
-
-
-
-
-
-
278458
278459
278460
-
-
-
-
108792
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZB150-50
-
-
-
ZB150-70
ZB150-100 278464
ZB150-125 278465
ZB150-150 278466
ZB150-175 107316
-
-
-
278462
-
-
-
278463
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 171
CA08103003Z_MOEM2015-EN.book Seite 171 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Bimetal Overload Relay
Overload relays
Bimetal Overload Relay
I r
A
Setting range
Overload releases
For use with
DILEM
Part no.
DILM7 - DILM15
Article no.
Part no.
Article no.
DILM17 - DILM38
Part no.
Article no.
DILM40 - DILM72
Part no.
Article no.
DILM80 - DILM170
Part no.
Article no.
Overload relay ZE, ZB
0.1 - 0.16
0.16 - 0.24
0.24 - 0.4
ZE-0,16
ZE-0,24
ZE-0,4
9 - 12
10 - 16
12 - 16
16 - 24
24 - 32
24 - 40
32 - 38
35 - 50
0.4 - 0.6
0.6 - 1
1 - 1.6
1.6 - 2.4
2.4 - 4
4 - 6
6 - 9
6 - 10
40 - 57
50 - 65
50 - 70
65 - 75
70 - 100
95 - 125
120 - 150
145 - 175
ZE-0,6
ZE-1,0
ZE-1,6
-
-
-
-
-
-
-
-
ZE-12
-
-
-
-
-
-
-
-
ZE-2,4
ZE-4
ZE-6
ZE-9
-
-
-
-
-
-
-
-
-
-
-
-
014518
014565
-
014708
-
-
-
014752
014263
014285
014300
014333
014376
014432
014479
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZB12-0,16 278431
ZB12-0,24 278432
ZB12-0,4 278433
ZB12-0,6
ZB12-1
ZB12-1,6
ZB12-2,4
ZB12-4
278434
278435
278436
278437
ZB12-6
ZB12-10
ZB12-12
278438
278439
-
278440
ZB12-16
-
278441
-
290168
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZB32-0,16 278442
ZB32-0,24 278443
ZB32-0,4 278444
ZB32-0,6
ZB32-1
ZB32-1,6
ZB32-2,4
ZB32-4
278445
278446
278447
278448
ZB32-6
ZB32-10
278449
278450
-
278451
ZB32-24
ZB32-32
ZB32-38
-
-
-
278453
-
278454
-
112474
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZB65-10
-
ZB65-16
-
ZB65-24
-
-
-
ZB65-40
ZB65-57
ZB65-65
-
-
-
-
ZB65-75
-
-
-
278455
-
278456
-
278457
-
-
-
-
-
-
-
-
-
-
278458
278459
278460
-
-
-
-
108792
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZB150-50
-
-
-
ZB150-70
ZB150-100 278464
ZB150-125 278465
ZB150-150 278466
ZB150-175 107316
-
-
-
278462
-
-
-
278463
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 172 Donnerstag, 7. April 2016 12:02 12
Overload relays
Overload relay, thermistor overload relay for machine protection
Overload relay, thermistor overload relay for machine protection
Setting range Overload releases
I r
A
For use with
Overload relay Z5
50 - 70
70 - 100
95 - 125
120 - 160
160 - 220
200 - 250
DILM185A
DILM225A
50 - 70
70 - 100
95 - 125
120 - 160
160 - 220
200 - 250
200 - 300
DILM250
DILM250
DILM300A
DILM300A
Part no.
Moeller® Series
Article no.
Z5-70/FF225A
Z5-100/FF225A
Z5-125/FF225A
Z5-160/FF225A
Z5-220/FF225A
Z5-250/FF225A
Z5-70/FF250
Z5-100/FF250
Z5-125/FF250
Z5-160/FF250
Z5-220/FF250
Z5-250/FF250
Z5-300/FF250
210070
210071
210072
210073
210074
210075
139578
139572
139573
139574
139575
139576
139577
Function
EMT6 thermistor overload relay for machine protection
Without manual reset
Mains and fault LED display
Without manual reset
Mains and fault LED display
With 2 sensor circuits
Without manual reset
Mains and fault LED display
Trip with short-circuit in the sensor cable
Part no.
EMT6
EMT6(230V)
EMT62
EMT6-K
Selector switch with/without manual reset
For manual or remote resetting
Test button
Mains and fault LED display
Selector switch with/without manual reset
For manual or remote resetting
Test button
Mains and fault LED display
With 2 sensor circuits
Selector switch with/without manual reset
For manual or remote resetting
Test button
Mains and fault LED display
Trip with short-circuit in the sensor cable
Multifunction device
Selector switch with/without manual reset
Trip with short-circuit in the sensor cable
Zero-voltage safe
For manual or remote resetting
Test button
Short-circuit recognition and zero-voltage safety can be deactivated
Mains and fault LED display
EMT6-DB
EMT6-DB(230V)
EMT62-DB
EMT6-KDB
EMT6-DBK
Article no.
066166
066400
171889
269470
066167
066401
171890
269471
066168
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 173 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Electronic motor-protective relay
Overload relays
Electronic motor-protective relay
Earth-fault protection
Setting range
Overload releases
I r
A
For use with
DILM7 - DILM15
Part no.
Article no.
Electronic overload relays ZEB
Direct mounting
None 0.33 - 1.65
1 - 5
4 - 20
9 - 45
20 - 100
35 - 175
With 0.33 - 1.65
1 - 5
4 - 20
9 - 45
20 - 100
35 - 175
Separate mounting
None
With 0.33 - 1.65
1 - 5
4 - 20
9 - 45
20 - 100
35 - 175
0.33 - 1.65
1 - 5
4 - 20
9 - 45
20 - 100
35 - 175
-
-
ZEB12-1,65
136480
ZEB12-5
136481
-
ZEB12-20
136482
-
-
ZEB12-1,65-GF
136483
ZEB12-5-GF
136484
-
ZEB12-20-GF
136485
-
-
-
-
-
-
-
-
-
-
-
-
DILM17 - DILM38
Part no.
Article no.
DILM40 - DILM72
Part no.
Article no.
DILM80 - DILM150
Part no.
Article no.
DILM185A - DILM225A
Part no.
Article no.
-
ZEB32-1,65
136486
ZEB32-5
136487
-
ZEB32-20
136488
ZEB32-45
136489
-
ZEB32-1,65-GF
136490
ZEB32-5-GF
136491
-
ZEB32-20-GF
136492
ZEB32-45-GF
136493
-
ZEB32-1,65/KK
136494
ZEB32-5/KK
136495
-
ZEB32-20/KK
136496
ZEB32-45/KK
136497
-
ZEB32-1,65-GF/KK
136498
ZEB32-5-GF/KK
136499
-
ZEB32-20-GF/KK
136500
ZEB32-45-GF/KK
136501
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZEB65-45
136502
-
ZEB65-100
136504
ZEB65-45-GF
136503
ZEB65-100-GF
136505
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZEB225-175
164307
-
-
-
ZEB225-175-GF
164308
-
-
-
-
-
-
ZEB150-100
136506
ZEB150-175
164303
-
-
ZEB150-100-GF
136507
ZEB150-175-GF
164304
-
-
-
-
-
ZEB150-100/KK
136508
ZEB150-175/KK
164305
-
-
-
ZEB150-100-GF/KK
136509
ZEB150-175-GF/KK
164306
EATON CORPORATION CA08103003Z-EN 173
CA08103003Z_MOEM2015-EN.book Seite 173 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Electronic motor-protective relay
Overload relays
Electronic motor-protective relay
Earth-fault protection
Setting range
Overload releases
I r
A
For use with
DILM7 - DILM15
Part no.
Article no.
DILM17 - DILM38
Part no.
Article no.
DILM40 - DILM72
Part no.
Article no.
DILM80 - DILM150
Part no.
Article no.
DILM185A - DILM225A
Part no.
Article no.
Electronic overload relays ZEB
Direct mounting
None 0.33 - 1.65
1 - 5
4 - 20
9 - 45
20 - 100
35 - 175
With 0.33 - 1.65
1 - 5
4 - 20
9 - 45
20 - 100
35 - 175
Separate mounting
None
With 0.33 - 1.65
1 - 5
4 - 20
9 - 45
20 - 100
35 - 175
0.33 - 1.65
1 - 5
4 - 20
9 - 45
20 - 100
35 - 175
-
-
ZEB12-1,65
136480
ZEB12-5
136481
-
ZEB12-20
136482
-
-
ZEB12-1,65-GF
136483
ZEB12-5-GF
136484
-
ZEB12-20-GF
136485
-
-
-
-
-
-
-
-
-
-
-
-
Complete assortment -> www.eaton.eu/ecat
-
ZEB32-1,65
136486
ZEB32-5
136487
-
ZEB32-20
136488
ZEB32-45
136489
-
ZEB32-1,65-GF
136490
ZEB32-5-GF
136491
-
ZEB32-20-GF
136492
ZEB32-45-GF
136493
-
ZEB32-1,65/KK
136494
ZEB32-5/KK
136495
-
ZEB32-20/KK
136496
ZEB32-45/KK
136497
-
ZEB32-1,65-GF/KK
136498
ZEB32-5-GF/KK
136499
-
ZEB32-20-GF/KK
136500
ZEB32-45-GF/KK
136501
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZEB65-45
136502
-
ZEB65-100
136504
-
-
-
-
ZEB65-45-GF
136503
ZEB65-100-GF
136505
EATON CA08103003Z-EN-INT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ZEB225-175
164307
-
-
-
ZEB225-175-GF
164308
-
-
-
-
-
-
ZEB150-100
136506
ZEB150-175
164303
-
-
ZEB150-100-GF
136507
ZEB150-175-GF
164304
-
-
-
-
-
ZEB150-100/KK
136508
ZEB150-175/KK
164305
-
-
-
ZEB150-100-GF/KK
136509
ZEB150-175-GF/KK
164306
Motor-protective circuit breakers
PKZ and PKE: Simple, intelligent, pluggable, versatile
ATEX www.eaton.eu/moem-ee
Motor-protective circuit breakers PKZ have been manufactured by
Eaton since 1932. Our ideas and developments have decisively influenced the trends in the protection of motors since then. The results are progressive concepts and marketable product innovations that again and again assume the role of international trendsetting, pioneering products, e.g. such as the motor-protective circuit breaker PKE.
Standstill times of machines and installation should be as short as possible. The fuseless motor-protective circuit breakers PKZ combine short-circuit protection and overload protection in a single device. This enables a short recovery time. PKZM0, PKZM01, PKZM4 and PKE feature the same range of accessories. They can be easily combined with contactors DILM and soft starters DS7. Switching technology can be this easy.
www.eaton.eu/pkz
174 EATON CA08103003Z-EN-INT
Perfect for actuation by pressing or hitting
The motor-protective circuit breaker PKZM01 for motors up to
25 A is ideal for small machines and other applications, which primarily prefer the use of push or impact operation. In addition to the auxiliary contacts from the PKZM0 range, there are also special enclosures in IP65 and IP40 degree of protection, also with an EMERGENCY STOP button. The short-circuit breaking capacity is 50 kA.
Common accessories – tool-less installation
Only two motor-protective circuit breakers are required to cover the range from 0.1 to 63 A. And this with only 20 different types. The motor-protective circuit breakers are matched to the contactor series DIL and can be easily combined to motor starters.
20min
10min
5min
2min
1min tripping characteristics
2s
1s
500ms
20s
10s
5s
200ms
100ms
50ms motor characteristics
20ms
10ms
5ms
2ms
1ms
1 1,2 1,5 2 2,5 3 4 5 7 10 12 15 20 25 30 40 50 70 100 120 150 200 250 300 400 500
The current when the motor is started and the inrush peak current both fall below the trip characteristic.
Possible magnetic release tolerances must be taken into account within the inrush peak current range
Modular design. Highest level of flexibility.
Highest level of performance
IE3-ready with Eaton switchgear
Motor- and system-protective circuit breaker PKE with electronic overload protection offers here an interesting alternative to the bimetal solution and complements the intelligent PKZ series. The motor-protective circuit breaker PKE provides the highest level of flexibility featuring a compact and modular design with plug-in control unit for motor currents up to 65 A.
Eaton's PKZM0, PKZM4, and PKE motor-protective circuit breakers are IE3-ready, and will safely and reliably switch and protect motors in the event of overloads and short-circuits.
The pick-up values for the short-circuit releases have been adjusted in line with the higher starting currents of IE3 motors.
This not only effectively prevents nuisance tripping, but also ensures safe operation.
Information at your fingertips thanks to SmartWire-DT
Motor starter combinations with PKZ and PKE enable integration into the automation environment via SmartWire-DT. The actual flow of current in the PKE can also be detected via the modular COM circuits. The data can be transferred directly into the control and is available across the system.
EATON CA08103003Z-EN-INT 175
3 basic units + 8 trip blocks = current range up to 65 A
12 A (45 mm)
PKE 12
32 A (45 mm)
PKE 32
65 A (55 mm)
PKE 65
Motor protection
0.3 A
0.09 - 5.5 kW (400 V)
System protection
12 A 1 A
0.37 - 15 kW (400 V)
32 A
15 A 36 A
8 A
15 A
4 - 30 kW (400 V)
65 A
65 A
8 plug-in trip blocks up to 65 A in 2 versions
0.3 A
1 A
3 A
1.2 A
4 A
8 A
16 A
15 A
12 A
32 A
16 A
65 A
36 A
65 A
Modular with a wide setting range
The functional safety and the service life of a motor depends mainly on the motor protection. Motor-protective circuit breaker PKE with electronic overload protection offers here an interesting alternative to the bimetal solution and complements the intelligent PKZ series from Eaton. The motor-protective circuit breaker PKE provides the highest level of flexibility featuring a compact and modular design with plugin control unit for motor currents up to
65 A. The large current setting ranges decisively reduce the number of variants and minimise the engineering work and costs accordingly.
PKZ and PKE in system xStart
The motor-protective circuit breakers
PKZ and PKE feature versatile, approved accessories available from the xStart range for safe and rational control panel construction. With most applications, an auxiliary switch is required with varying contact assignment for interlock or for signalling purposes. The motor starter design with two separate contact systems including visible isolating gaps enables a unique assignment of the protective devices
PKZ or PKE and switching device DIL, whereby switchgear devices can be exchanged individually. A universal accessory series from the system xStart facilitates economy in logistical terms and reduces engineering costs.
Always well informed
• Current values
• Diagnostics data
• Status messages
• Overload relay function
176 EATON CA08103003Z-EN-INT
Information at your fingertips thanks to SmartWire-DT
Motor starter combinations with PKZ and PKE enable integration into the automation environment via Smart-
Wire-DT. The most varying array of signalling functions can be transferred with the PKZ using the modular COM circuits. The motor-protective circuit breaker PKE also utilizes diagnostics, status and overload messages and detects the current flow. The data can be transferred directly into the control and is available across the system. The data transparency created enhances the efficiency and the operational reliability of the drives in the operation environment of the motor-protective circuit breaker.
Moeller® series
4
3
5
1
Motor-protective circuit breakers
System Overview
6
7
2
8
9
12
13
10
17
10
11
14
15
21 18
10
22
19
11
16
22
20
28
29
23
27
23
24
25
T
24
26
26
26
1 Motor-protective circuit breaker PKE 12/32
2 Motor-protective circuit breaker PKE 65
3 Motor-protective circuit breaker PKZM01
4 Undervoltage release/shunt release
5 Feeder terminal block
6 Trip-indicating auxiliary contact
7 Side mounted auxiliary contact
8 PKE-XZMR electronic overload relay module
9 Door-coupling rotary handle and shaft extension
10 Front mounted auxiliary contact
11 SmartWire-DT communication interface for PKE
12 Combination plug-in connector
13 Mechanical plug-in connector
14 Motor starter link
15 Electrical plug-in connector
16 Electrical plug-in connector
17 Contactor up to 15 A
18 Contactor up to 38 A
30
19 Contactor up to 65 A
20 Side mounted auxiliary contact
21 Side mounted auxiliary contact
22 Side mounted auxiliary contact
23 Suppressor
24 Surface mounted auxiliary contact
25 Electronic timer
26 Surface mounted auxiliary contact
27 DOL starter MSC-DEA up to 5.5 kW with PKE
28 Busbar adapter
29 DIN rail adapter plate
30 SmartWire-DT PKE module
EATON CA08103003Z-EN-INT 177
CA08103003Z_MOEM2015-EN.book Seite 178 Donnerstag, 7. April 2016 12:02 12
Motor-protective circuit-breakers
Basic devices Moeller® series
Basic devices
Setting range
Overload releases
I r
A
Screw terminals
Part no.
Article no.
PKZM01 motor-protective circuit-breaker, Type "1" and "2" coordination
0.1 - 0.16
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4
4 - 6.3
6.3 - 10
8 - 12
10 - 16
16 - 20
20 - 25
PKZM0 motor-protective circuit-breaker, Type "1" and "2" coordination
4 - 6.3
6.3 - 10
8 - 12
10 - 16
16 - 20
20 - 25
25 - 32
0.1 - 0.16
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4
PKZM4 motor-protective circuit-breaker, Type "1" and "2" coordination
10 - 16
16 - 25
24 - 32
32 - 40
40 - 50
50 - 58
55 - 65
UL circuit-breaker in accordance with NFPA 79
10 - 16
16 - 25
24 - 32
PKZM01-0,16
PKZM01-0,25
PKZM01-0,4
PKZM01-0,63
PKZM01-1
PKZM01-1,6
PKZM01-2,5
PKZM01-4
PKZM01-6,3
PKZM01-10
PKZM01-12
PKZM01-16
PKZM01-20
PKZM01-25
PKZM0-0,16
PKZM0-0,25
PKZM0-0,4
PKZM0-0,63
PKZM0-1
PKZM0-1,6
PKZM0-2,5
PKZM0-4
PKZM0-6,3
PKZM0-10
PKZM0-12
PKZM0-16
PKZM0-20
PKZM0-25
PKZM0-32
PKZM4-16
PKZM4-25
PKZM4-32
PKZM4-40
PKZM4-50
PKZM4-58
PKZM4-63
PKZM4-16-CB 132591
PKZM4-25-CB 132592
PKZM4-32-CB 132593
222350
222352
222353
222354
222355
222394
222413
278475
278476
278477
278478
278479
278480
278481
278482
278483
278484
278485
283390
283383
288893
072738
072739
278486
046938
046988
046989
278489
072730
072731
072732
072733
072734
072735
072736
072737
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Incoming side screw terminals outgoer side springloaded terminals
Part no.
Article no.
Spring-loaded terminals
Part no.
Article no.
PKZM0-0,16-SC 229828
PKZM0-0,25-SC 229829
PKZM0-0,4-SC 229830
PKZM0-0,63-SC 229831
PKZM0-1-SC 229832
PKZM0-1,6-SC 229833
PKZM0-2,5-SC 229834
PKZM0-4-SC
-
-
229835
PKZM0-6,3-SC 229836
PKZM0-10-SC 229837
PKZM0-12-SC 278487
-
PKZM0-16-SC 229838
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
PKZM0-0,16-C 229669
PKZM0-0,25-C 229670
PKZM0-0,4-C 229671
PKZM0-0,63-C 229672
PKZM0-1-C
PKZM0-1,6-C
PKZM0-2,5-C
PKZM0-4-C
PKZM0-6,3-C
229673
229674
229675
229676
PKZM0-10-C
PKZM0-12-C
PKZM0-16-C
-
-
-
229677
229678
278488
229679
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Transformer-protective circuit-breaker
0.1 - 0.16
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4
4 - 6.3
6.3 - 10
8 - 12
10 - 16
16 - 20
20 - 25
PKZM0-0,16-T 088907
PKZM0-0,25-T 088908
PKZM0-0,4-T 088909
PKZM0-0,63-T 088910
PKZM0-1-T
PKZM0-1,6-T
PKZM0-2,5-T
PKZM0-4-T
PKZM0-6,3-T
088911
088912
088913
088914
PKZM0-10-T
PKZM0-12-T
PKZM0-16-T
PKZM0-20-T
PKZM0-25-T
088915
088916
278492
088917
088918
278493
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 179 Donnerstag, 7. April 2016 12:02 12
Moeller® series
PKE basic devices and trip blocks
Motor-protective circuit-breakers
PKE basic devices and trip blocks
Setting range of overload releases
Basic device with standard knob Trip block motor protection
Standard
I r
A
Part no.
Article no.
Part no.
Article no.
Motor-protective circuit-breakers PKE, type “1” and “2”coordination
0.3 - 1.2
1 - 4
3 - 12
8 - 32
PKE12
PKE12
PKE12
PKE12
121721
121721
121721
121721
PKE-XTU-1,2
PKE-XTU-4
PKE-XTU-12
PKE-XTU-32
121723
121724
121725
121726
Trip block motor protection
Advanced
Connection to SmartWire-DT with PKE-SWD-32 or PKE-SWD-SP
Part no.
Article no.
Complete device with standard knob
Part no.
Article no.
PKE-XTUA-1,2
PKE-XTUA-4
PKE-XTUA-12
PKE-XTUA-32
121727
121728
121729
121730
PKE12/XTU-1,2
PKE12/XTU-4
PKE12/XTU-12
PKE32/XTU-32
121731
121732
121733
121734
I r
A
Setting range of overload releases
Basic device with standard knob
Part no.
Article no.
Trip block system protection
Standard
Part no.
Article no.
PKE system protective circuit-breaker, short-circuit release 5-8 x l
15 - 36 PKE32 121722 r
PKE-XTUCP-36 153164
Trip block system protection
Advanced
Connection to SmartWire-DT with PKE-SWD-CP
Part no.
Article no.
PKE-XTUACP-36 168795
Complete device with standard knob
Part no.
PKE32/XTUCP-36
Article no.
168972
Setting range of overload releases
Basic device with standard knob Trip block motor protection
Standard
I r
A
Part no.
Article no.
Part no.
Article no.
Motor-protective circuit-breakers PKE, type “1” and “2”coordination
8 - 32
16 - 65
PKE65
PKE65
138258
138258
PKE-XTUW-32 138261
PKE-XTU-65 138259
Trip block motor protection
Advanced
Connection to SmartWire-DT with PKE-SWD-SP
Part no.
Article no.
Complete device with standard knob
Part no.
Article no.
PKE-XTUWA-32
PKE-XTUA-65
138262
138260
PKE65/XTUW-32
PKE65/XTU-65
138517
138516
I r
A
Setting range of overload releases
Basic device with standard knob
Part no.
Article no.
Trip block system protection
Standard
Part no.
Trip block system protection
Advanced
Connection to SmartWire-DT with PKE-SWD-CP
Article no.
Part no.
Article no.
PKE system protective circuit-breaker, short-circuit release 5-8 x l
15 - 36 PKE65 138258 r
PKE-XTUWCP-36 168796
30 - 65 PKE65 138258 PKE-XTUCP-65 168798
PKE-XTUWACP-36
PKE-XTUACP-65
168797
168799
Complete device with standard knob
Part no.
Article no.
PKE65/XTUWCP-36 168973
PKE65/XTUCP-65 168974
EATON CORPORATION CA08103003Z-EN 179
CA08103003Z_MOEM2015-EN.book Seite 179 Donnerstag, 7. April 2016 12:02 12
Moeller® series
PKE basic devices and trip blocks
Motor-protective circuit-breakers
PKE basic devices and trip blocks
Setting range of overload releases
Basic device with standard knob Trip block motor protection
Standard
I r
A
Part no.
Article no.
Part no.
Article no.
Motor-protective circuit-breakers PKE, type “1” and “2”coordination
0.3 - 1.2
1 - 4
3 - 12
8 - 32
PKE12
PKE12
PKE12
PKE12
121721
121721
121721
121721
PKE-XTU-1,2
PKE-XTU-4
PKE-XTU-12
PKE-XTU-32
121723
121724
121725
121726
Trip block motor protection
Advanced
Connection to SmartWire-DT with PKE-SWD-32 or PKE-SWD-SP
Part no.
Article no.
Complete device with standard knob
Part no.
Article no.
PKE-XTUA-1,2
PKE-XTUA-4
PKE-XTUA-12
PKE-XTUA-32
121727
121728
121729
121730
PKE12/XTU-1,2
PKE12/XTU-4
PKE12/XTU-12
PKE32/XTU-32
121731
121732
121733
121734
I r
A
Setting range of overload releases
Basic device with standard knob
Part no.
Article no.
Trip block system protection
Standard
Part no.
Article no.
PKE system protective circuit-breaker, short-circuit release 5-8 x l
15 - 36 PKE32 121722 r
PKE-XTUCP-36 153164
Trip block system protection
Advanced
Connection to SmartWire-DT with PKE-SWD-CP
Part no.
Article no.
PKE-XTUACP-36 168795
Complete device with standard knob
Part no.
PKE32/XTUCP-36
Article no.
168972
Setting range of overload releases
Basic device with standard knob Trip block motor protection
Standard
I r
A
Part no.
Article no.
Part no.
Article no.
Motor-protective circuit-breakers PKE, type “1” and “2”coordination
8 - 32
16 - 65
PKE65
PKE65
138258
138258
PKE-XTUW-32 138261
PKE-XTU-65 138259
Trip block motor protection
Advanced
Connection to SmartWire-DT with PKE-SWD-SP
Part no.
Article no.
Complete device with standard knob
Part no.
Article no.
PKE-XTUWA-32
PKE-XTUA-65
138262
138260
PKE65/XTUW-32
PKE65/XTU-65
138517
138516
I r
A
Setting range of overload releases
Basic device with standard knob
Part no.
Article no.
Trip block system protection
Standard
Part no.
Trip block system protection
Advanced
Connection to SmartWire-DT with PKE-SWD-CP
Article no.
Part no.
Article no.
PKE system protective circuit-breaker, short-circuit release 5-8 x l
15 - 36 PKE65 138258 r
PKE-XTUWCP-36 168796
30 - 65 PKE65 138258 PKE-XTUCP-65 168798
PKE-XTUWACP-36
PKE-XTUACP-65
168797
168799
Complete device with standard knob
Part no.
Article no.
PKE65/XTUWCP-36 168973
PKE65/XTUCP-65 168974
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 180 Donnerstag, 7. April 2016 12:02 12
Motor-protective circuit-breakers
SmartWire-DT® PKE modules, busbar adapter
SmartWire-DT® PKE modules, busbar adapter
SmartWire-DT PKE (motor-protective circuit-breaker)
For connecting the motor-protective circuit-breaker with PKE-XTU(W)A-... trip blocks(motor protection) to SmartWire-DT
Fitted on PKE motor-protective circuit-breaker
Messages
Contactor state PKE
Motor current in %
Thermal motor image in %
Trip indications (Overload, Short-circuit,...)
Set value of overload releases
Set time lag (CLASS)
Part no. of trip block
Commands
Remote disconnection of motor-protective circuit-breaker
SmartWire-DT PKE module (circuit-breakers)
For connecting the PKE circuit-breaker with PKE-XTU(W)ACP-... trip blocks(motor protection) to SmartWire-DT
For attachment to PKE circuit-breakers
Messages
Contactor state PKE
All phase currents in %
Thermal load as a %
Trip indications (Overload, Short-circuit,...)
Set value of overload releases
Set short-circuit release value
Part no. of trip block
Commands
Remote circuit-breaker de-energization
Busbar adapters for PKZ and PKE
25
Rated operational current
I e
A
For use with
25
32
PKZM0, PKE + DILM7
PKZM0, PKE + DILM9
PKZM0, PKE + DILM12
PKZM0, PKE + DILM15
MSC-D-0.25-M7… - MSC-D-16-M15…
PKZM0, PKE + 2 x DILM7-01
PKZM0, PKE + 2 x DILM9-01
PKZM0, PKE + 2 x DILM12-01
MSC-R-0,25-M7… - MSC-R-12-M12…
PKZM0, PKE + DILM(C)17
PKZM0, PKE + DILM(C)25
PKZM0, PKE + DILM(C)32
32
63
PKZM0, PKE + 2 x DILM(C)17-01
PKZM0, PKE + 2 x DILM(C)25-01
PKZM0, PKE + 2 x DILM(C)32-01
PKZM4, PKE65 + DILM(C)17
PKZM4, PKE65 + DILM(C)25
PKZM4, PKE65 + DILM(C)32
PKZM4, PKE65 + DILM(C)40
PKZM4, PKE65 + DILM(C)50
PKZM4, PKE65 + DILM(C)65
Part no.
Moeller® series
Article no.
PKE-SWD-SP 150614
PKE-SWD-CP 172735
Part no.
Article no.
BBA0-25 101451
BBA0R-25 101453
BBA0-32 101452
BBA0R-32 101454
BBA4L-63 101459
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 181 Donnerstag, 7. April 2016 12:02 12
Motor-protective circuit-breakers
Moeller® series
Accessories
Contacts
N/O = Normally open
Standard auxiliary contact
1 N/O
1 N/O
1 N/O
2 N/O
N/C = Normally closed
1 NC
1 NC
2 NC
1 NC
For use with
PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE
1 N/O
-
1 N/O
1 N/O
1 NC
-
-
1 NC
Trip-indicating auxiliary contacts
2 x 1 N/O
-
-
2 x 1 NC
PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE
Auxiliary contacts, early-make
2 N/O -
2 N/O -
PKZM0
PKZM0-T
PKM0
PKZM4
PKZM01
Shunt release
-
-
-
PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE
Undervoltage release
-
-
-
-
Overload relay function module
1 N/O
1 N/O
1 NC
1 NC
Part no.
NHI11-PKZ0
NHI11-PKZ0-C
NHI12-PKZ0
NHI21-PKZ0
NHI-E-11-PKZ0
NHI-E-10-PKZ0
NHI-E-10-PKZ0-C
NHI-E-01-PKZ0-C
AGM2-10-PKZ0
AGM2-01-PKZ0
VHI20-PKZ0
VHI20-PKZ01
A-PKZ0(230V50HZ)
A-PKZ0(24VDC)
PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE
U-PKZ0(230V50HZ)
U-PKZ0(24VDC)
PKE12
PKE32
PKE65 with XTUA trip block with release 04 and higher
PKE-XZMR(24VDC)
PKE-XZMR(230V50HZ)
Accessories
Article no.
072896
229680
072895
072894
082882
082884
229681
229682
072898
072899
203595
278495
073187
073200
073135
157862
173425
173416
Rotary handle, lockable
For locking motor-protective circuit-breakers PKZM0, PKZM4 and PKE as a main switch in compliance with EN 60204
Can be padlocked in the “0” position with a padlock
Hasp thickness: 3 – 6.35 mm
AK-PKZ0 030851
EATON CORPORATION CA08103003Z-EN 181
CA08103003Z_MOEM2015-EN.book Seite 181 Donnerstag, 7. April 2016 12:02 12
Motor-protective circuit-breakers
Moeller® series
Accessories
Contacts
N/O = Normally open
Standard auxiliary contact
1 N/O
1 N/O
1 N/O
2 N/O
N/C = Normally closed
1 NC
1 NC
2 NC
1 NC
For use with
PKZM01
PKZM0
PKZM4
PKZM0-T
PKM0
PKE
1 N/O
-
1 N/O
1 N/O
1 NC
-
-
1 NC
Trip-indicating auxiliary contacts
2 x 1 N/O
-
-
2 x 1 NC
PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE
Auxiliary contacts, early-make
2 N/O -
2 N/O -
PKZM0
PKZM0-T
PKM0
PKZM4
PKZM01
Shunt release
-
-
-
PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE
Undervoltage release
-
-
-
-
Overload relay function module
1 N/O
1 N/O
1 NC
1 NC
Part no.
NHI11-PKZ0
NHI11-PKZ0-C
NHI12-PKZ0
NHI21-PKZ0
NHI-E-11-PKZ0
NHI-E-10-PKZ0
NHI-E-10-PKZ0-C
NHI-E-01-PKZ0-C
AGM2-10-PKZ0
AGM2-01-PKZ0
VHI20-PKZ0
VHI20-PKZ01
A-PKZ0(230V50HZ)
A-PKZ0(24VDC)
PKZM0
PKZM4
PKZM0-T
PKM0
PKZM01
PKE
U-PKZ0(230V50HZ)
U-PKZ0(24VDC)
PKE12
PKE32
PKE65 with XTUA trip block with release 04 and higher
PKE-XZMR(24VDC)
PKE-XZMR(230V50HZ)
Accessories
Article no.
072896
229680
072895
072894
082882
082884
229681
229682
072898
072899
203595
278495
073187
073200
073135
157862
173425
173416
Rotary handle, lockable
For locking motor-protective circuit-breakers PKZM0, PKZM4 and PKE as a main switch in compliance with EN 60204
Can be padlocked in the “0” position with a padlock
Hasp thickness: 3 – 6.35 mm
AK-PKZ0 030851
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 182 Donnerstag, 7. April 2016 12:02 12
Motor-protective circuit-breakers
Accessories
Accessories
For use with
Three-phase commoning link, incoming unit via terminals 1, 3, 5
For PKZM0-... or PKE without side mounted auxiliary contacts or shunt releases
-
-
-
-
Attached on the right, for motor-protective circuit-breakers, with an auxiliary contact or trip-indicating auxiliary contact
-
-
-
-
For PKZM0-... or PKE: attached with an auxiliary contact and a trip-indicating auxiliary contact on the right or attached on the left with a shunt release
-
-
Incoming terminal
PKZM0
PKE
PKZM0
Shroud for unused terminals
Protection against direct contact.
For covering unused terminals on three-phase commoning link B3...-PKZ0
Wiring set
For DOL Starter
Plug-in
Screwable
PKZM0, PKE + DILM7
PKZM0, PKE + DILM9
PKZM0, PKE + DILM12
PKZM0, PKE + DILM15
PKZM0, PKE + DILM7
PKZM0, PKE + DILM9
PKZM0, PKE + DILM12
PKZM0, PKE + DILM15
PKZM0, PKE + DILM17
PKZM0, PKE + DILM25
PKZM0, PKE + DILM32
PKZM0, PKE + DILM7
PKZM0, PKE + DILM9
PKZM0, PKE + DILM12
PKZM0, PKE + DILM15
For reversing starters
PKZM0, PKE + DILM7-01
PKZM0, PKE + DILM9-01
PKZM0, PKE + DILM12-01
PKZM0, PKE + DILM17
PKZM0, PKE + DILM25
PKZM0, PKE + DILM32
EATON CA08103003Z-EN-INT
Part no.
Article no.
B3.0/2-PKZ0
B3.0/3-PKZ0
B3.0/4-PKZ0
B3.0/5-PKZ0
B3.1/2-PKZ0
B3.1/3-PKZ0
B3.1/4-PKZ0
B3.1/5-PKZ0
B3.2/2-PKZ0
B3.2/4-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0-E
H-B3-PKZ0
063961
232289
063960
232290
044945
044946
044947
044948
063963
063959
032720
262518
032721
Moeller® series
PKZM0-XDM12 283149
PKZM0-XDM15ME 179646
PKZM0-XDM32 283153
PKZM4-XDM65 101053
PKZM0-XRM12
PKZM0-XRM32
283185
283189
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 183 Donnerstag, 7. April 2016 12:02 12
Motor-protective circuit-breakers
Moeller® series
Accessories, Type E starters
Description For use with
Wiring set
Electric contact module
Door coupling handles
For use as main switch to IEC/EN 60204
For use as a main switch to EN 60204 in MCC power distribution systems and with PKZM0 installed when rotated by 90°
For use as main switch to IEC/EN 60204
For use as a main switch to EN 60204 in MCC power distribution systems and with PKE installed when rotated by 90°
For use as a main switch with Emergency-Stop function, to EN 60204
For use as a main switch with Emergency-Stop function to EN 60204 in
MCC power distribution systems and with PKZM0 installed when rotated by 90°
For use as a main switch with Emergency-Stop function, to EN 60204
For use as a main switch with Emergency-Stop function to EN 60204 in MCC power distribution systems and with PKE installed when rotated by 90°
PKZM0
PKZM4
PKZM0
PKZM4
PKE
PKE
PKZM0
PKZM4
PKZM0
PKZM4
PKE
PKE
PKZM0, PKE + DILM17
PKZM0, PKE + DILM25
PKZM0, PKE + DILM32
DS7-34…SX016…
DS7-34…SX024…
DS7-34…SX032…
PKZM4, PKE65 + DILM40
PKZM4, PKE65 + DILM50
PKZM4, PKE65 + DILM65
Accessories, Type E starters
Part no.
PKZM0-XM32DE
PKZM4-XM65DE
PKZ0-XH
PKZ0-XH-MCC
PKE-XH
PKE-XH-MCC
PKZ0-XRH
PKZ0-XRH-MCC
PKE-XRH
PKE-XRH-MCC
Article no.
239349
101056
106132
106136
142416
142418
106133
106137
142417
142419
Manual Self-Protected Combination Controller UL 60947-4-1, Type E
PKZM0(4) motor-protective circuit-breakers, used as "Manual self-protected Motor Starters" – UL 508 Type E
Maximum motor output
HP = PS
200 V
208 V
230 V
240 V
460 V
480 V
575 V
600 V
Setting ranges
Overload releases
Short-circuit releases
Interrupting Capacity =
Short Circuit Current Rating SCCR
240 V 480Y/
277 V 2)
600Y/
347 V 2)
[HP] [HP] [HP] [HP] [A] [A] [kA] [kA] [kA]
1)
7½
10
–
15
–
5
7½
10
–
5
–
3
3
½
¾
1½
5
7½
10
–
–
3
–
7½
–
5
3
3
2
½
¾
½
Notes
Components
Motor
Protector
Accessories
Type Type
20
30
30
40
50
20
25
10
50
7½
10
10
15
5
3
¾
1½
15
20
30
30
40
15
20
10
40
5
7½
10
–
3
2
1
¾
0.1 – 0.16
0.16 – 0.25
0.25 – 0.4
0.4 – 0.63
0.63 – 1
1 – 1.6
1.6 – 2,5
2.5 – 4
4 – 6.3
6.3 – 10
8 – 12
10 – 16
16 – 20
20 – 25
25 – 32
10 – 16
16 – 25
25 – 32
32 – 40
40 – 50
50 – 58
55 – 65
2.5
3.9
6.2
9.8
16
25
39
62
98
155
186
248
310
388
496
248
388
496
620
775
899
977
65
65
65
65
65
65
65
65
65
65
65
42
18
18
18
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
42
18
18
18
65
65
65
65
65
65
65
50
–
–
50
50
50
50
50
50
50
50
50
–
–
–
25
25
25
25
–
–
–
PKZM0-0.16
PKZM0-0.25
PKZM0-0.4
PKZM0-0.63
PKZM0-1
PKZM0-1.6
PKZM0-2.5
PKZM0-4
PKZM0-6.3
PKZM0-10
PKZM0-12
PKZM0-16
PKZM0-20
PKZM0-25
PKZM0-32
PKZM4-16
PKZM4-25
PKZM4-32
PKZM4-40
PKZM4-50
PKZM4-58
PKZM4-63
1)
2)
Calculate instance motor power in this range according to the rated operational current. Stated values to NEC Table 430 -150
Suitable for networks with earthed star-point
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
EATON CORPORATION CA08103003Z-EN 183
CA08103003Z_MOEM2015-EN.book Seite 183 Donnerstag, 7. April 2016 12:02 12
Motor-protective circuit-breakers
Moeller® series
Accessories, Type E starters
Description For use with
Wiring set
Electric contact module
Door coupling handles
For use as main switch to IEC/EN 60204
For use as a main switch to EN 60204 in MCC power distribution systems and with PKZM0 installed when rotated by 90°
For use as main switch to IEC/EN 60204
For use as a main switch to EN 60204 in MCC power distribution systems and with PKE installed when rotated by 90°
For use as a main switch with Emergency-Stop function, to EN 60204
PKZM0
PKZM4
PKZM0
PKZM4
PKE
PKE
For use as a main switch with Emergency-Stop function to EN 60204 in
MCC power distribution systems and with PKZM0 installed when rotated by 90°
For use as a main switch with Emergency-Stop function, to EN 60204
For use as a main switch with Emergency-Stop function to EN 60204 in MCC power distribution systems and with PKE installed when rotated by 90°
PKZM0
PKZM4
PKZM0
PKZM4
PKE
PKE
PKZM0, PKE + DILM17
PKZM0, PKE + DILM25
PKZM0, PKE + DILM32
DS7-34…SX016…
DS7-34…SX024…
DS7-34…SX032…
PKZM4, PKE65 + DILM40
PKZM4, PKE65 + DILM50
PKZM4, PKE65 + DILM65
Accessories, Type E starters
Part no.
PKZM0-XM32DE
PKZM4-XM65DE
PKZ0-XH
PKZ0-XH-MCC
PKE-XH
PKE-XH-MCC
PKZ0-XRH
PKZ0-XRH-MCC
PKE-XRH
PKE-XRH-MCC
Article no.
239349
101056
106132
106136
142416
142418
106133
106137
142417
142419
Manual Self-Protected Combination Controller UL 60947-4-1, Type E
PKZM0(4) motor-protective circuit-breakers, used as "Manual self-protected Motor Starters" – UL 508 Type E
Maximum motor output
HP = PS
200 V
208 V
230 V
240 V
460 V
480 V
575 V
600 V
Setting ranges
Overload releases
Short-circuit releases
Interrupting Capacity =
Short Circuit Current Rating SCCR
240 V 480Y/
277 V 2)
600Y/
347 V 2)
[HP] [HP] [HP] [HP] [A] [A] [kA] [kA] [kA]
1)
10
–
15
–
7½
10
5
7½
–
5
–
3
3
½
¾
1½
–
–
7½
10
5
3
–
7½
–
5
3
3
2
½
¾
½
Notes
Components
Motor
Protector
Accessories
Type Type
30
30
40
50
20
25
10
20
50
7½
10
10
15
5
3
¾
1½
20
30
30
40
15
20
10
15
40
5
7½
10
–
3
2
1
¾
0.1 – 0.16
0.16 – 0.25
0.25 – 0.4
0.4 – 0.63
0.63 – 1
1 – 1.6
1.6 – 2,5
2.5 – 4
4 – 6.3
6.3 – 10
8 – 12
10 – 16
16 – 20
20 – 25
25 – 32
10 – 16
16 – 25
25 – 32
32 – 40
40 – 50
50 – 58
55 – 65
2.5
3.9
6.2
9.8
16
25
39
62
98
155
186
248
310
388
496
248
388
496
620
775
899
977
65
65
65
65
65
65
65
65
65
65
65
42
18
18
18
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
42
18
18
18
65
65
65
65
65
65
65
50
–
–
50
50
50
50
50
50
50
50
50
–
–
–
25
25
25
25
–
–
–
PKZM0-0.16
PKZM0-0.25
PKZM0-0.4
PKZM0-0.63
PKZM0-1
PKZM0-1.6
PKZM0-2.5
PKZM0-4
PKZM0-6.3
PKZM0-10
PKZM0-12
PKZM0-16
PKZM0-20
PKZM0-25
PKZM0-32
PKZM4-16
PKZM4-25
PKZM4-32
PKZM4-40
PKZM4-50
PKZM4-58
PKZM4-63
1) Calculate instance motor power in this range according to the rated operational current. Stated values to NEC Table 430 -150
2) Suitable for networks with earthed star-point
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK25/3-PKZ0-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 184 Donnerstag, 7. April 2016 12:02 12
Motor-protective circuit-breakers
PKZM0 switching capacity Moeller® series
PKZM0 switching capacity Circuit-breaker switching capacity from serial no. 04
Rated uninterrupted current I u
Rated conditional short-circuit current I q
IEC/EN 60947-4-1
Rated ultimate short-circuit breaking capacity I
Rated service short-circuit breaking capacity I cu cs
IEC/EN 60947-2
IEC/EN 60947-2
I u
A
I
230 V q
I cu
I cs kA kA kA A 1)
I
400 V q
I cu
PKZM0, PKZM0...-T, PKM0 with type 1 and 2 coordination
I cs kA kA kA A 1)
20
25
32
6.3
10
12
16
0.16 – 1
1.6
4
2.5
150 150 150 N
150 150 150 N
150 150 150 N
150 150 150 N
150 150 150 N
150 150 150 N
50 50
50 50
50 50
50 50
50 40
38
38
38
38
10
50
50
50
50
50
150 150 150 N
150 150 150 N
150 150 150 N
150 150 150 N
150 150 150 N
150 150 150 N
50 50
50 50
50 50
50 50
50 40
38
38
38
38
10
50
50
50
50
50
PKZM0 (PKZM0...-T, PKM0) + CL-PKZ0
20
25
32
6.3
10
12
16
0.16 – 1
1.6
4
2.5
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
I
440 V q
I cu
I cs kA kA kA A
50
50
50
50
50
50
50
15
15
10
10
10
3
3
3
50
12
12
1)
N
N
N
N
N
50
50
50
50
50
50
N
N
N
N
N
N
N
N
N
N
N
I
500 V q kA kA kA A
42
15
15
10
10
10
10
10
10
I
3
3
3 cu
42
15
15
10
10
10
I
3
3
4
4
3 cs
11
10
10
10
50
20
20
20
1)
N
N
N
N
N
50
50
50
50
50
50
N
N
N
N
N
N
N
N
N
N
N
3
3
3
3
3
3
3
I
690 V q kA kA kA A
50
5
5
5
5
5
20
20
20
20
3
3
3
3
3
3
3
I cu
50
5
5
5
5
5
20
20
20
20
1
1
2
2
2
3
1
I cs
50
1)
PKZM0 (PKZM0...-T, PKM0) + 2 CL-PKZ0
20
25
32
6.3
10
12
16
0.16 – 1
1.6
4
2.5
Notes
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
20
20
20
20
20
20
20
20
20
50
40
40
40
N
N
N
N
N
N
N
N
N
N
N
10
10
10
10
10
40
40
20
20
10
10
10
10
10
40
40
20
20
20
20
20
20
20
20
N
N
2.5
N
2.5
N
N
N
N
N
2.5
N
2.5
N
2.5
N
No upstream protective device required, as it is the auto-protected range (100/150 kA)
N Not Required
1) Necessary back-up fuse when the short-circuit current exceeds the rated conditional short-circuit current of the device (I cc
. I q
).
20
20
20
20
20
20
N
N
2.5
N
2.5
N
N
N
N
N
2.5
N
2.5
N
2.5
N
50
50
50
50
N
N
N
50
50
50
50
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 185 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Motor-protective circuit-breakers
PKZM01, PKZM4 switching capacity
PKZM01, PKZM4 switching capacity Circuit-breaker switching capacity
Rated uninterrupted current I u
Rated conditional short-circuit current I q
IEC/EN 60947-4-1
Rated ultimate short-circuit breaking capacity I
Rated service short-circuit breaking capacity I cu cs
IEC/EN 60947-2
IEC/EN 60947-2
I u
A
32
40
50
58
63
Notes
50
50
50
50
50
I
230 V q
I cu
I cs kA kA kA A 1)
PKZM01 with type 1 and 2 coordination
0.16 – 1 50 50 50
10
12
16
1.6
2.5
4
6.3
50
50
50
50
50
50
50
50
50
50
50
50
50
50
20, 25 50 50 10
PKZM4 with type 1 and 2 coordination
16
25
150 150 25
150 150 25
50
10
10
50
50
50
50
50
50
50
50
50
25
25
25
25
25
50
50
50
50
50
50
50
50
50
N
N
100
100
100
160
160
I
400 V q kA kA kA A 1)
50
50
50
50
50
50
50
50
I cu
50 50
50
50
50
50
50
50
50
50
I cs
50
50
50
50
50
50
10
10
10
150 150 25
150 150 25
50 50
50 50
50 50
50 50
50 50
25
25
25
25
25
N
N
100
100
100
160
160
No upstream protective device required,as it is the auto-protected range (150 kA)
50
50
50
50
50
50
50
50
50
I
440 V 2) q
I cu
I cs kA kA kA A 1)
42
15
15
10
50 50
50
50
50
50
50
50
50
50
42
15
15
10
N Not Required
3
10
10
10
50
50
50
50
50
50
50
50
50
50
50
50
50
50
I
500 V q
2)
I cu
I cs kA kA kA A 1)
I
690 V q
2)
I cu
I cs kA kA kA A 1)
45
45
45
45
45 45
45 45
45 45
45 45
45 45
1)
2)
25
25
25
25
25
25
25
100
100
100
100
100
160
160
15
15
15
15
15
15
15
15
15
15
15
15
15
15
100
100
100
100
100
160
160
8
8
5
5
5
5
5
8
8
5
5
5
5
5
2.5
2.5
2.5
2.5
100
100
2.5
100
2.5
100
2.5
100
160
160
Fuse (A gG/gL) for enhancing the switching capacity of the motor-protective circuit-breaker to 100 kA
Please enquire for additional information regarding voltages > 400 V and device combinations with CL-PKZ0.
I u
A
I
230/400 V q kA
I cu kA
I cs kA
I
415 V q kA
I cu kA
I cs kA
I
440 V q kA
4
PKE12/XTU(A)-... with type 1 and 2 coordination
1.2
100
100
50
50
12 100
PKE32/XTU(A)-... with type 1 and 2 coordination
50
32 100 50
PKE32/XTUCP(A)-... with type 1 and 2 coordination
15
50
20
25
36 - 50 12.5
-
PKE65/XTU(W)(A) with type 1 and 2 coordination
-
32 - 65 80 80 45
Motor-starter combinations MSC-DE(A)-…-M7(12)... with type 1 coordination
4
1.2
100
100
50
50
15
50
12 100 50 50
Motor-starter combinations MSC-DE(A)-…-M17(32)... with type 1 coordination
4
12
32
100
100
65
100
65
65
Motor-starter combinations MSC-DE(A)-…-M17(32)... with type 2 coordination
1.2
100 65 65
12
32
100
100
100
65
65
100
PKE12/XTU-...+DILM17+CL-PKZ0 with type 2 coordination
1.2 - 12 100 100
PKE32/XTU-32+DILM32+CL-PKZ0 with type 2 coordination
32 100 100
PKE65/XTU(A)-65+DILM(40, 50)65 with type 2 coordination
65 80 50
65
65
65
100
100
50
I cu kA
I cs kA
6
-
I
500 V q kA
I cu kA
10
10
20
15
10
50
20
50
50
10
50
50
50
100
100
50
I cs kA
3
5
3
-
-
-
I
525 V q kA
I cu kA
10
10
10
10
-
-
50
3
50
20
-
10
I cs kA
5
3
-
-
5
-
3
3
3
3
-
-
5
-
-
-
I
690 V q kA
I cu kA
-
10
I cs kA
EATON CORPORATION CA08103003Z-EN 185
CA08103003Z_MOEM2015-EN.book Seite 185 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Motor-protective circuit-breakers
PKZM01, PKZM4 switching capacity
PKZM01, PKZM4 switching capacity Circuit-breaker switching capacity
Rated uninterrupted current I u
Rated conditional short-circuit current I q
IEC/EN 60947-4-1
Rated ultimate short-circuit breaking capacity I
Rated service short-circuit breaking capacity I cu cs
IEC/EN 60947-2
IEC/EN 60947-2
I u
A
32
40
50
58
63
Notes
I
230 V q
I cu
I cs kA kA kA A 1)
PKZM01 with type 1 and 2 coordination
0.16 – 1 50 50 50
10
12
16
1.6
2.5
4
6.3
50
50
50
50
50
50
50
50
50
50
50
50
50
50
20, 25 50 50 10
PKZM4 with type 1 and 2 coordination
16
25
150 150 25
150 150 25
50
10
10
50
50
50
50
50 50
50 50
50 50
50 50
50 50
25
25
25
25
25
50
50
50
50
50
50
50
50
50
N
N
100
100
100
160
160
I
400 V q kA kA kA A 1)
50
50
I cu
50
50 50
50 50
50 50
50 50
50 50
50 50
50 50
50
I cs
50
50
50
50
50
50
10
10
10
150 150 25
150 150 25
50 50
50 50
50 50
50 50
50 50
25
25
25
25
25
N
N
100
100
100
160
160
No upstream protective device required,as it is the auto-protected range (150 kA)
50
50
50
50
50
50
50
50
50
N Not Required
440 V 2)
I q
I cu
I cs kA kA kA A 1)
50 50
50 50
50 50
50 50
50 50
42 42
15 15
15 15
10 10 3
10
10
10
50
50
50
50
50
50
50
50
50
50
50
50
50
50
I
500 V 2) q
I cu
I cs kA kA kA A 1)
I
690 V 2) q
I cu
I cs kA kA kA A 1)
45 45
45 45
45 45
45 45
45 45
45 45
45 45
1)
2)
25
25
25
25
25
25
25
100
100
100
100
100
160
160
15
15
15 15
15 15
15
15
15
15
15
15
15
15
100
100
100
100
100
160
160
8
8
5
5
5
5
5
8
8
5
5
5
5
5
2.5
2.5
2.5
2.5
100
100
2.5
100
2.5
100
2.5
100
160
160
Fuse (A gG/gL) for enhancing the switching capacity of the motor-protective circuit-breaker to 100 kA
Please enquire for additional information regarding voltages > 400 V and device combinations with CL-PKZ0.
I u
A
I
230/400 V q kA
I cu kA
I cs kA
I
415 V q kA
I cu kA
I cs kA
I
440 V q kA
4
PKE12/XTU(A)-... with type 1 and 2 coordination
1.2
100
100
50
50
12 100
PKE32/XTU(A)-... with type 1 and 2 coordination
50
32 100 50
PKE32/XTUCP(A)-... with type 1 and 2 coordination
15
50
20
25
36 - 50 12.5
-
PKE65/XTU(W)(A) with type 1 and 2 coordination
-
32 - 65 80 80 45
Motor-starter combinations MSC-DE(A)-…-M7(12)... with type 1 coordination
4
1.2
100
100
50
50
15
50
12 100 50 50
Motor-starter combinations MSC-DE(A)-…-M17(32)... with type 1 coordination
4
12
32
100
100
65
100
65
65
Motor-starter combinations MSC-DE(A)-…-M17(32)... with type 2 coordination
1.2
100 65 65
12
32
100
100
100
65
65
100
PKE12/XTU-...+DILM17+CL-PKZ0 with type 2 coordination
1.2 - 12 100 100
PKE32/XTU-32+DILM32+CL-PKZ0 with type 2 coordination
32 100 100
PKE65/XTU(A)-65+DILM(40, 50)65 with type 2 coordination
65 80 50
65
65
65
100
100
50
I cu kA
I cs kA
6
-
I
500 V q kA
I cu kA
10
10
20
15
10
50
20
50
50
10
50
50
50
100
100
50
I cs kA
3
5
3
-
-
-
I
525 V q kA
I cu kA
10
10
10
10
-
-
50
3
50
20
-
10
I cs kA
5
3
-
-
5
-
3
3
3
3
-
-
5
-
-
-
I
690 V q kA
I cu kA
-
10
I cs kA
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Motor starter system xStart
Fast and flexible assembly and connection
www.eaton.eu/moem-ee
Eaton offers a comprehensive offer for starting the motor with the motor start system xStart: From protective to soft starting devices and motor protection using bimetal relays, to motor-protective circuit breakers with electronic wide-range overload protection. All of these standard components can be easily combined using simple mechanical and electronic connectors. Three-phase commoning links offer comfortable assistance for motor current wiring. SmartWire-DT also replaces the control current wiring and integrates comprehensive communication options into the system.
186 www.eaton.eu/xstart
EATON CA08103003Z-EN-INT
Motor starter system xStart
Fast and flexible assembly and connection
Just a short step to a starter combination Flexible energy distribution
On xStart switchgear up to 15.5 A, plug-in main and auxiliary current connections replace the classical wiring. With the standard individual components PKZM0 / PKE and the wiring set for direct-on-line starters or reversing starters for contactors or soft start devices with screw terminals, DOL starters, soft starters or reversing starters can be created in seconds.
The wiring kits include the complete main current wiring between the motor-protective circuit breaker and contactor
DIL up 15.5 A or the soft starter DS7. The electrical interlock and the reversing links are included in addition to the main current connection with the reversing starter set PKZM0-XRM12.
Whether it’s a motor starter, soft starter or just motor-protective circuit breakers, with the product-specific BBA busbar adapters from Eaton, a flexible energy supply/distribution can be quickly and easily established. The users have the specific adapters for the motor-protective circuit breakers, such as the
PKZM0, PKE and PKZM4 with rated currents of 0.1 to 63 A, as well as other universal adapters up to 80 A. Their standardcompliant dimensions fit on all 60 mm busbar systems from leading manufacturers. They are approved for both the European and North American markets with their UL/ CSA approvals. The new busbar adapters support installation of starter combinations, which have been assembled using tool-less plug connection technology from the motor starter range.
They are available as individual units or complete motor starters.
➞ Complete solutions save time and money
The wiring classic
Eaton offers the optimum wiring links for every motor-protective circuit breaker type such as the PKZM0, PKZM4 or PKE.
Optionally, several motor-protective circuit breakers are available on cut-to-fit three-phase commoning links for parallel power feed. Matched to the corresponding application, whether it is a side-mounted auxiliary contact or undervoltage or shunt release.
Important for machine export to North America!
New National Electrical Code (NEC 2011) for the USA.
The UL 508 Type E – Manual Self-Protected Combination
Motor Controllers – used in great numbers in the USA, and for even longer in Canada, must be equipped with a padlockable knob. The levers can be exchanged with padlockable types on the motor-protective circuit breakers from Eaton.
EATON CA08103003Z-EN-INT 187
Motor-starter combinations with PKE, all information accessible
The motor-protective circuit breaker PKE with electronic widerange overload protection can be integrated in just a few simple steps via SmartWire-DT into the communication structure of the automation system. This facilitates a more in-depth view of the motor output circuit load and provides additional optimization potential for system availability. The respective
SmartWire-DT modules facilitate the communication connection for compact PKE motor starter combinations up to 32 A motor current and the direct connection to the motor-protective circuit breaker PKE up to 65 A motor current.
Connection technology in the control panel
Manufacturers of machines and systems strive to achieve a balance between the maximum level of functionality and cost optimization. SmartWire-DT is a communication system for industrial switchgear based on the concept of continued development in the control panel and peripherals: from control through to protection and switching, and extending to driving, operation and monitoring.
Electronic motor starter EMS – longer life at only 30 mm
Starting Reversing
Protecting Stopping
A key requirement in machinery construction is the availability of compact, multifunctional switchgear that saves space in in today’s ever smaller control panels as well as cutting engineering and installation times.
With electronic motor starter EMS Eaton offers a multifunctional device complete with built-in motor protection in a device that measures only 30 mm in width. The electronic motor starter offers up to four motor starter functions in a single device, which saves space in the control panel as well as time in installation and commissioning.
The standardized push-in technology for main and control current terminals further minimizes the time needed to install the electronic motor starter.
The electronic motor starter is used for reliably controlling and protecting motors in the performance range of
0.06 kW/400 V to 3 kW/400 V.
188 EATON CA08103003Z-EN-INT
The multifunctional interface Lean solutions: Direct-on-line starters/Reversing starters made of standard components
Unbeatable time-saving applications such as reversing starters or star-delta combinations can be implemented with the integrated tool-less plug connection interface of the contactors
DILM(C) up to 15.5 A. The plug-on accessories or the wiring sets for the tool-less plug connections also offer the opportunity for motor interference suppression, the adaptation of customized contactor controls using solder pin adapters or the external motor cables with the PE connection of the contactor.
Direct-on-line starters made of standard components are available in four narrow sizes. Contactors and circuit breakers feature the same compact width. No precious millimeter of control panel space is wasted. The convenient MSC motor starters using tool-less plug connection technology are available up to
15 A and require only a top-hat rail for mounting. The mechanical connector ensures a secure hold, and the electrical connector provides optimum reliability and safety. Complete mounting connectors are offered for DOL and reversing starters from 16 up to
32 A. This prevents fitting errors and cuts down on wiring time.
➞ Up to a rating of 170 A, the circuit breaker and the contactor will have the same width. This ensures that the motor starter will take up as little space as possible when installed in an enclosure.
➞ Compact motor starters with a rating of up to 65 A can be implemented by using the PKE motor-protective circuit breaker with electronic wide-range overload protection.
Tested motor-starter combinations: quick selection – easy ordering
Enter motor data Select a motor starter
Select a contactor Generate order list
Whether you want to configure your motor starter as a DOL, reversing, or wyedelta starter. Whether you prefer a fused or fuseless configuration. Whether you want an electromechanical motor starter or an electronic motor starter: Eaton’s motor starter configurator will take you through the process step by step in just a few clicks. You can have only IE3-ready switchgear and combinations be shown. Moreover, the configurator is linked to our online catalog, ensuring that you will enjoy convenient access to our entire range of products, including wiring sets.
Once finished, you can then send the finished list to your sales partner -- it’s as simple as that.
www.eaton.eu/ selectiontools
EATON CA08103003Z-EN-INT 189
Motor-starter combinations
Standard
Motor data
AC-3
380V
400V
415V
P I
Rated operational current
400V e kW A
11
15
18.5
22
30
34
3
4
1.5
2.2
5.5
7.5
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
37
45
55
75
90
110
132
160
200
250
21.7
29.3
36
41
55
63
3.6
5
6.6
8.5
11.3
15.2
0.6
0.8
1.1
1.5
1.9
2.6
0.21
0.31
0.41
68
81
99
134
161
196
231
279
349
437
Rated shortcircuit current
380-415V
I q kA
50
50
50
50
50
50
150 / 50*
150 / 50*
150 / 50*
150
50
50
150 / 50*
150 / 50*
150 / 50*
150 / 50*
150 / 50*
150 / 50*
150 / 50*
150 / 50*
150 / 50*
50
50
50
50
50
50
50
50
50
50
Motor-protective circuit breaker
PKZM0-4
PKZM0-6,3
PKZM0-10
PKZM0-10
PKZM0-12
PKZM0-16
PKZM0-25
PKZM0-32
PKZM4-40
PKZM4-50
PKZM4-58
PKZM4-63
PKZM0-0,25
PKZM0-0,4
PKZM0-0,63
PKZM0-0,63
PKZM0-1
PKZM0-1,6
PKZM0-1,6
PKZM0-2,5
PKZM0-4
NZMN1-M80
NZMN1-M100
NZMN1-M100
NZMN2-M160
NZMN2-M200
NZMN2-M200
DILM80
DILM95
DILM115
DILM150
DILM185A
DILM225A
DILM80
DILM95
DILM115
DILM150
DILM185A
DILM225A
NZMN3-ME350 DILM250
NZMN3-ME350 DILM300A
DILM250
DILM300A
NZMN3-ME350 DILM400 DILM400
NZMN3-ME450 DILM500 DILM500
* Coordination type 2
DILM7-…
DILM7-…
DILM7-…
DILM9-…
DILM12-…
DILM17-...
DILM25-…
DILM32-…
DILM40
DILM50
DILM65
DILM65
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM25-…
DILM32-…
DILM40
DILM50
DILM65
DILM65
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
190 EATON CA08103003Z-EN-INT
Contactor coordination type “1”
Moeller® series
Contactor coordination type “2”
Moeller® series
22
30
34
37
45
55
4
5.5
7.5
11
15
18.5
0.55
0.75
1.1
1.5
2.2
3
0.06
0.09
0.12
0.18
0.25
0.37
75
90
110
132
160
200
250
Motor data
AC-3
380V
400V
415V
P
Rated operational current
400V
I e kW A
Rated shortcircuit current
380-415V
I q kA
41
55
63
68
81
99
8.5
11.3
15.2
21.7
29.3
36
1.5
1.9
2.6
3.6
5
6.6
0.21
0.31
0.41
0.6
0.8
1.1
134
161
196
231
279
349
437
80
80
80
100
100
100
100
100
100
100
100
80
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Motor-starter combinations
with Electronic Overload Release
Motor-protective circuit breaker
Contactor coordination type “1”
PKE12/XTU-1,2
PKE12/XTU-1,2
PKE12/XTU-1,2
PKE12/XTU-1,2
PKE12/XTU-1,2
PKE12/XTU-1,2
PKE12/XTU-4
PKE12/XTU-4
PKE12/XTU-4
PKE12/XTU-4
PKE12/XTU-12
PKE12/XTU-12
PKE12/XTU-12
PKE12/XTU-12
PKE32/XTU-32
PKE32/XTU-32
DILM9-…
DILM12-…
DILM17-…
DILM25-…
PKE32/XTU-32 DILM32-…
PKE65/XTUW-65 DILM40
PKE65/XTUW-65 DILM50
PKE65/XTUW-65 DILM65
PKE65/XTUW-65 DILM65
NZMH2-ME90 DILM80
NZMH2-ME90 DILM95
NZMH2-ME140 DILM115
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
DILM7-…
NZMH2-ME140 DILM150
NZMH2-ME220 DILM185A
NZMH2-ME220 DILM225A
NZMH3-ME350 DILM250
NZMH3-ME350 DILM300A
NZMH3-ME350 DILM400
NZMH3-ME450 DILM500
Contactor coordination type “2”
DILM17-…
DILM17-…
DILM17-…
DILM25-…
DILM32-…
DILM40
DILM50
DILM65
DILM65
DILM80
DILM95
DILM115
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM17-…
DILM150
DILM185A
DILM225A
DILM250
DILM300A
DILM400
DILM500
EATON CA08103003Z-EN-INT 191
CA08103003Z_MOEM2015-EN.book Seite 192 Donnerstag, 7. April 2016 12:02 12
Motor-starter combinations
DOL starters, reversing starters
Complete devices MSC-R
150
150
150
150
150
150
150
150
150
150
50
50
50
50
50
50
-
-
50
50
-
50
50
50
50
50
50
50
50
50
50
50
0.16 - 0.25
MSC-R-0,25-M7(230V50HZ) 283171
0.25 - 0.4
MSC-R-0,4-M7(230V50HZ) 283172
0.4 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
MSC-R-0,63-M7(230V50HZ)
MSC-R-1-M7(230V50HZ)
283173
283175
MSC-R-1,6-M7(230V50HZ) 283176
MSC-R-2,5-M7(230V50HZ) 283178
2.5 - 4
4 - 6.3
6.3 - 10
6.3 - 10
8 - 12
MSC-R-4-M7(230V50HZ)
MSC-R-12-M12(230V50HZ)
283179
MSC-R-6,3-M7(230V50HZ) 283181
MSC-R-10-M7(230V50HZ) 283182
MSC-R-10-M9(230V50HZ) 283183
283184
6.3 - 10
8 - 12
10 - 16
20 - 25
25 - 32
MSC-R-10-M17(230V50HZ) 101049
MSC-R-12-M17(230V50HZ) 101050
MSC-R-16-M17(230V50HZ) 283186
MSC-R-25-M25(230V50HZ) 283187
MSC-R-32-M32(230V50HZ) 283188
MSC-R-0,25-M7(24VDC)
MSC-R-0,4-M7(24VDC)
MSC-R-0,63-M7(24VDC)
MSC-R-1-M7(24VDC)
MSC-R-1,6-M7(24VDC)
MSC-R-2,5-M7(24VDC)
MSC-R-4-M7(24VDC)
MSC-R-6,3-M7(24VDC)
MSC-R-10-M7(24VDC)
MSC-R-10-M9(24VDC)
MSC-R-12-M12(24VDC)
MSC-R-10-M17(24VDC)
MSC-R-12-M17(24VDC)
MSC-R-16-M17(24VDC)
MSC-R-25-M25(24VDC)
MSC-R-32-M32(24VDC)
283190
283191
283192
283194
283195
283197
283198
283200
283201
283202
283203
101051
101052
283204
283205
283206
EATON CA08103003Z-EN-INT
Moeller® series
Motor-starter combinationsDOL starters, reversing starters
Complete units MSC-D
150
150
150
50
50
150
150
150
150
150
150
150
50
50
50
50
50
Motor ratings
Rated short-circuit current 380 - 415 V
Type of coordination “1”
I q
Type of coordination “2”
I q kA kA
-
-
-
-
50
50
50
50
50
50
50
50
50
50
50
50
50
I
A r
Setting range of overload releases
AC operation
230 V 50 Hz
Part no.
DC operation
24 V DC
Article no.
Part no.
0.16 - 0.25
MSC-D-0,25-M7(230V50HZ) 281925
0.25 - 0.4
MSC-D-0,4-M7(230V50HZ) 281926
0.4 - 0.63
MSC-D-0,63-M7(230V50HZ) 281927
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4
MSC-D-1-M7(230V50HZ) 281929
MSC-D-1,6-M7(230V50HZ) 283140
MSC-D-2,5-M7(230V50HZ) 283142
MSC-D-4-M7(230V50HZ) 283143
4 - 6.3
6.3 - 10
6.3 - 10
8 - 12
10 - 16
MSC-D-6,3-M7(230V50HZ) 283145
MSC-D-10-M7(230V50HZ) 283146
MSC-D-10-M9(230V50HZ) 283147
MSC-D-12-M12(230V50HZ) 283148
MSC-D-16-M15(230V50HZ) 100414
6.3 - 10
8 - 12
10 - 16
20 - 25
25 - 32
MSC-D-10-M17(230V50HZ) 101045
MSC-D-12-M17(230V50HZ) 101046
MSC-D-16-M17(230V50HZ) 283150
MSC-D-25-M25(230V50HZ) 283151
MSC-D-32-M32(230V50HZ) 283152
Article no.
MSC-D-0,25-M7(24VDC)
MSC-D-0,4-M7(24VDC)
MSC-D-0,63-M7(24VDC)
MSC-D-1-M7(24VDC)
MSC-D-1,6-M7(24VDC)
MSC-D-2,5-M7(24VDC)
MSC-D-4-M7(24VDC)
MSC-D-6,3-M7(24VDC)
MSC-D-10-M7(24VDC)
MSC-D-10-M9(24VDC)
MSC-D-12-M12(24VDC)
MSC-D-16-M15(24VDC)
MSC-D-10-M17(24VDC)
MSC-D-12-M17(24VDC)
MSC-D-16-M17(24VDC)
MSC-D-25-M25(24VDC)
MSC-D-32-M32(24VDC)
283154
283155
283156
283158
283159
283161
283162
283164
283165
283166
283167
100415
101047
101048
283168
283169
283170
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 193 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Motor-starter combinations
DOL starters, Type F starter combinations
Motor-starter combinations DOL starters, Type F starter combinations
Motor ratings
Rated short-circuit current 380 - 400 V
Type of coordination “1”
I q
Type of coordination “2”
I q kA kA
MSC-DE complete devices with PKE
100
100
100
100
100
100
100
100
100
-
-
100
100
-
-
-
100
100
I r
A
Setting range of overload releases
AC operation
230 V 50 Hz
Part no.
0.3 - 1.2
1 - 4
3 - 12
3 - 12
3 - 12
3 - 12
8 - 32
8 - 32
8 - 32
Article no.
MSC-DE-1,2-M7(230V50HZ) 121735
MSC-DE-4-M7(230V50HZ) 121737
MSC-DE-12-M7(230V50HZ) 121739
MSC-DE-12-M9(230V50HZ) 121741
MSC-DE-12-M12(230V50HZ) 121743
MSC-DE-12-M17(230V50HZ) 121745
MSC-DE-32-M17(230V50HZ) 121747
MSC-DE-32-M25(230V50HZ) 121749
MSC-DE-32-M32(230V50HZ) 121751
DC operation
24 V DC
Part no.
MSC-DE-1,2-M7(24VDC)
MSC-DE-4-M7(24VDC)
MSC-DE-12-M7(24VDC)
MSC-DE-12-M9(24VDC)
MSC-DE-12-M12(24VDC)
MSC-DE-12-M17(24VDC)
MSC-DE-32-M17(24VDC)
MSC-DE-32-M25(24VDC)
MSC-DE-32-M32(24VDC)
Article no.
5
5
7½
3
3
1½
3
½
½
1
1
1½
3
7½
7½
10
2
3
1
2
10
15
20
½
¾
1
½
¾
5
7½
10
3
5
1½
3
½
½
1
1
1½
10
15
15
PKZM4, DIL, BK modules
3
5
7½
10
5
7½
10
15
10
15
25
30
15
20
30
30
15
15
15
30
40
40
-
-
-
-
-
5
10
3
5
1½
3
-
-
-
½
½
1
1
1½
Notes
Combination Motor Starter UL 60947-4-1, Type F
Maximum motor rating Setting range
Alternating current HP = PS
200 V
208 V
230 V
240 V
460 V
480 V
575 V
600 V
Overload trip Short-circuit releases
Non-delayed
HP HP HP HP I r
A
I rm
A
I
PKZM0, DIL, BK modules
1)
1.6 - 2.5
2.5 - 4
2.5 - 4
4 - 6.3
4 - 6.3
6.3 - 11
9 - 12
10 - 16
16 - 20
20 - 25
25 - 32
0.1 - 0.16
0.1 - 0.16
0.16 - 0.25
0.16 - 0.25
0.25 - 0.4
0.25 - 0.4
0.4 - 0.63
0.4 - 0.63
0.63 - 1
0.63 - 1
1 - 1.6
1 - 1.6
1.6 - 2.5
88
140
168
224
35
56
56
88
280
350
448
14
22
22
35
5.6
8.8
8.8
14
2.2
2.2
3.4
3.4
5.6
65
65
65
18
50
50
50
50
18
18
18
50
50
50
50
50
50
50
50
50
50
50
50
50
Rated short-circuit breaking capacity I cn
240 V 480 Y
277 V
600 Y
347 V kA kA
65
65
65
18
50
50
50
50
18
18
18
50
50
50
50
50
50
50
50
50
50
50
50
50 kA
18
18
-
18
18
50
18
50
-
-
-
18
50
18
50
18
50
18
50
50
18
50
18
50
Extension terminal
Type
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
Motor protective circuit breakers
Contactor
Type
PKZM0-2,5
PKZM0-4
PKZM0-4
PKZM0-6,3
PKZM0-6,3
PKZM0-10
PKZM0-12
PKZM0-16
PKZM0-20
PKZM0-25
PKZM0-32
PKZM0-0,16
PKZM0-0,16
PKZM0-0,25
PKZM0-0,25
PKZM0-0,4
PKZM0-0,4
PKZM0-0,63
PKZM0-0,63
PKZM0-1
PKZM0-1
PKZM0-1,6
PKZM0-1,6
PKZM0-2,5
Type
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILM9-…(…)
DILM12-…(…)
DILM17-…(…)
DILM25-…(…)
DILM25-…(…)
DILM32-…(…)
10 - 16
16 - 27
24 - 34
32 - 40
40 - 52
50 - 56
52 - 58
224
350
448
560
700
812
882
65
65
65
65
65
65
65
65
65
65
65
65
65
65
-
-
-
30
30
50
50
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
PKZM4-16
PKZM4-25
PKZM4-32
PKZM4-40
PKZM4-50
PKZM4-58
PKZM4-63
DILM17-…(…)
DILM25-…(…)
DILM32-…(…)
DILM40(…)
DILM50(…)
DILM65(…)
DILM65(…)
1) Calculate motor power in this range according to the rated operational current. Stated values to NEC Table 430 - 150.
121736
121738
121740
121742
121744
121746
121748
121750
121752
EATON CORPORATION CA08103003Z-EN 193
CA08103003Z_MOEM2015-EN.book Seite 193 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Motor-starter combinations
DOL starters, Type F starter combinations
Motor-starter combinations DOL starters, Type F starter combinations
Motor ratings
Rated short-circuit current 380 - 400 V
Type of coordination “1”
I q
Type of coordination “2”
I q kA kA
MSC-DE complete devices with PKE
100
100
100
100
100
100
100
100
100
-
-
100
100
-
-
-
100
100
I r
A
Setting range of overload releases
AC operation
230 V 50 Hz
Part no.
0.3 - 1.2
1 - 4
3 - 12
3 - 12
3 - 12
3 - 12
8 - 32
8 - 32
8 - 32
Article no.
MSC-DE-1,2-M7(230V50HZ) 121735
MSC-DE-4-M7(230V50HZ) 121737
MSC-DE-12-M7(230V50HZ) 121739
MSC-DE-12-M9(230V50HZ) 121741
MSC-DE-12-M12(230V50HZ) 121743
MSC-DE-12-M17(230V50HZ) 121745
MSC-DE-32-M17(230V50HZ) 121747
MSC-DE-32-M25(230V50HZ) 121749
MSC-DE-32-M32(230V50HZ) 121751
DC operation
24 V DC
Part no.
MSC-DE-1,2-M7(24VDC)
MSC-DE-4-M7(24VDC)
MSC-DE-12-M7(24VDC)
MSC-DE-12-M9(24VDC)
MSC-DE-12-M12(24VDC)
MSC-DE-12-M17(24VDC)
MSC-DE-32-M17(24VDC)
MSC-DE-32-M25(24VDC)
MSC-DE-32-M32(24VDC)
Article no.
5
5
7½
3
3
1½
3
½
½
1
1
1½
3
7½
7½
10
2
3
1
2
10
15
20
½
¾
1
½
¾
5
7½
10
3
5
1½
3
½
½
1
1
1½
10
15
15
PKZM4, DIL, BK modules
3
5
7½
10
5
7½
10
15
10
15
25
30
15
20
30
30
15
15
15
30
40
40
-
-
-
-
-
5
10
3
5
1½
3
-
-
-
½
½
1
1
1½
Notes
Combination Motor Starter UL 60947-4-1, Type F
Maximum motor rating Setting range
Alternating current HP = PS
200 V
208 V
230 V
240 V
460 V
480 V
575 V
600 V
Overload trip Short-circuit releases
Non-delayed
HP HP HP HP I r
A
I rm
A
I
PKZM0, DIL, BK modules
1)
1.6 - 2.5
2.5 - 4
2.5 - 4
4 - 6.3
4 - 6.3
6.3 - 11
9 - 12
10 - 16
16 - 20
20 - 25
25 - 32
0.1 - 0.16
0.1 - 0.16
0.16 - 0.25
0.16 - 0.25
0.25 - 0.4
0.25 - 0.4
0.4 - 0.63
0.4 - 0.63
0.63 - 1
0.63 - 1
1 - 1.6
1 - 1.6
1.6 - 2.5
88
140
168
224
35
56
56
88
280
350
448
14
22
22
35
5.6
8.8
8.8
14
2.2
2.2
3.4
3.4
5.6
65
65
65
18
50
50
50
50
18
18
18
50
50
50
50
50
50
50
50
50
50
50
50
50
Rated short-circuit breaking capacity I cn
240 V 480 Y
277 V
600 Y
347 V kA kA
65
65
65
18
50
50
50
50
18
18
18
50
50
50
50
50
50
50
50
50
50
50
50
50 kA
18
18
-
18
18
50
18
50
-
-
-
18
50
18
50
18
50
18
50
50
18
50
18
50
Extension terminal
Type
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
BK25/3-PKZ0
Motor protective circuit breakers
Contactor
Type
PKZM0-2,5
PKZM0-4
PKZM0-4
PKZM0-6,3
PKZM0-6,3
PKZM0-10
PKZM0-12
PKZM0-16
PKZM0-20
PKZM0-25
PKZM0-32
PKZM0-0,16
PKZM0-0,16
PKZM0-0,25
PKZM0-0,25
PKZM0-0,4
PKZM0-0,4
PKZM0-0,63
PKZM0-0,63
PKZM0-1
PKZM0-1
PKZM0-1,6
PKZM0-1,6
PKZM0-2,5
Type
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILEM…(…)
DILM7-…(…)
DILM9-…(…)
DILM12-…(…)
DILM17-…(…)
DILM25-…(…)
DILM25-…(…)
DILM32-…(…)
10 - 16
16 - 27
24 - 34
32 - 40
40 - 52
50 - 56
52 - 58
224
350
448
560
700
812
882
65
65
65
65
65
65
65
65
65
65
65
65
65
65
-
-
-
30
30
50
50
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
BK50/3-PKZ4-E
PKZM4-16
PKZM4-25
PKZM4-32
PKZM4-40
PKZM4-50
PKZM4-58
PKZM4-63
DILM17-…(…)
DILM25-…(…)
DILM32-…(…)
DILM40(…)
DILM50(…)
DILM65(…)
DILM65(…)
1) Calculate motor power in this range according to the rated operational current. Stated values to NEC Table 430 - 150.
121736
121738
121740
121742
121744
121746
121748
121750
121752
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 194 Donnerstag, 7. April 2016 12:02 12
Motor-starter combinations
DOL starters, connection to SmartWire-DT
Motor-starter combinationsDOL starters, connection to SmartWire-DT
Motor ratings
Rated short-circuit current 380 - 400 V
Type of coordination “1”
I q
Type of coordination “2”
I q kA kA
I r
A
Setting range of overload releases
MSC-DEA complete devices with PKE, prepared for SmartWire-DT connection
100 0.3 - 1.2
100
100 -
1 - 4
3 - 12
100
100 -
3 - 12
3 - 12
-
-
-
-
-
AC operation
230 V 50 Hz
Part no.
-
-
-
-
-
DC operation
24 V DC
Article no.
Part no.
Moeller® series
Article no.
MSC-DEA-1,2-M7(24VDC) 121753
MSC-DEA-4-M7(24VDC) 121754
MSC-DEA-12-M7(24VDC) 121755
MSC-DEA-12-M9(24VDC) 121756
MSC-DEA-12-M12(24VDC) 121757
100
100
100
100
100
100
100
100
3 - 12
8 - 32
8 - 32
8 - 32
-
-
-
-
-
-
-
MSC-DEA-12-M17(24VDC) 121758
MSC-DEA-32-M17(24VDC) 121759
MSC-DEA-32-M25(24VDC) 121760
MSC-DEA-32-M32(24VDC) 121761
CA08103003Z_MOEM2015-EN.book Seite 195 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Motor-starter combinations
DOL starters/Reversing starter on busbar adapter
Motor-starter combinations DOL starters/Reversing starter on busbar adapter
Motor ratings
Rated short-circuit current
380 - 415 V
Type of coordination
Type of coordination
I
“1” q
I
“2” q kA kA
PKZ and DILM complete devices on BBA for DOL starters
100 50
100
50
50
50
100
100
50
100
100
100
100
100
100
100
100
100
50
50
50
50
-
-
-
50
50
50
-
50
50
50
50
50
I r
A
Setting range of overload releases
AC operation
230 V 50 Hz
Part no.
Article no.
0.16 - 0.25
MSC-D-0,25-M7(230V50HZ)/BBA 102737
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
MSC-D-0,4-M7(230V50HZ)/BBA
MSC-D-0,63-M7(230V50HZ)/BBA
MSC-D-1-M7(230V50HZ)/BBA
MSC-D-1,6-M7(230V50HZ)/BBA
102738
102739
102950
102951
1.6 - 2.5
2.5 - 4
4 - 6.3
6.3 - 10
6.3 - 10
8 - 12
10 - 16
6.3 - 10
8 - 12
10 - 16
20 - 25
25 - 32
MSC-D-2,5-M7(230V50HZ)/BBA
MSC-D-4-M7(230V50HZ)/BBA
MSC-D-6,3-M7(230V50HZ)/BBA
MSC-D-10-M7(230V50HZ)/BBA
MSC-D-10-M9(230V50HZ)/BBA
MSC-D-12-M12(230V50HZ)/BBA
MSC-D-16-M15(230V50HZ)/BBA
MSC-D-10-M17(230V50HZ)/BBA
MSC-D-12-M17(230V50HZ)/BBA
MSC-D-16-M17(230V50HZ)/BBA
MSC-D-25-M25(230V50HZ)/BBA
MSC-D-32-M32(230V50HZ)/BBA
102952
102953
102954
102955
102956
102957
102958
102959
102960
102961
102962
102963
DC operation
24 V DC
Part no.
Article no.
MSC-D-0,25-M7(24VDC)/BBA 102964
MSC-D-0,4-M7(24VDC)/BBA 102965
MSC-D-0,63-M7(24VDC)/BBA 102966
MSC-D-1-M7(24VDC)/BBA 102967
MSC-D-1,6-M7(24VDC)/BBA 102968
MSC-D-2,5-M7(24VDC)/BBA 102969
MSC-D-4-M7(24VDC)/BBA 102970
MSC-D-6,3-M7(24VDC)/BBA 102971
MSC-D-10-M7(24VDC)/BBA 102972
MSC-D-10-M9(24VDC)/BBA 102973
MSC-D-12-M12(24VDC)/BBA 102974
MSC-D-16-M15(24VDC)/BBA 102975
MSC-D-10-M17(24VDC)/BBA 102976
MSC-D-12-M17(24VDC)/BBA 102977
MSC-D-16-M17(24VDC)/BBA 102978
MSC-D-25-M25(24VDC)/BBA 102979
MSC-D-32-M32(24VDC)/BBA 102980
Part no.
Article no.
SmartWire-DT PKE module (motor-starter combinations)
For connecting PKE motor-starter combination MSC-DEA… with PKE-XTUA-... trip blocks with a rated motor output of 15 kW/400 V to
SmartWire-DT
Mounting on DILM contactor with 24 V DC control voltage.
One module per contactor and PKE necessary
Additional SWD contactor module required fir actuation of reversing starter.
1 electrical interlock for the surface mounting of reversing starters.
1-0-A switch for manual or automatic operation.
Selectable overload relay function (ZMR) for switching off the contactor on overload.
Wiring sets DILM 12-XRL and PKZM0-XRM12 cannot be used.
For current consumption of the contactor coils > 3 A (UL/CSA > 2 A) use additional power feeder module.
A2 connections must not be bridged.
Messages
Switch position contactor/PKE/1-0-A switch
Motor current in %
Thermal motor image in %
Trip indications (Overload, Short-circuit,...)
Set value of overload releases
Set time lag (CLASS)
Part no. of trip block
Commands
Contactor actuation
Activation Overload relay function (ZMR)
PKE-SWD-32 126895
PKZ and DILM complete devices on BBA for reversing starters
100
100
100
100
50
50
50
50
0.16 - 0.25
MSC-R-0,25-M7(230V50HZ)/BBA 102981
0.25 - 0.4
MSC-R-0,4-M7(230V50HZ)/BBA 102982
0.4 - 0.63
0.63 - 1
MSC-R-0,63-M7(230V50HZ)/BBA
MSC-R-1-M7(230V50HZ)/BBA
102983
102984
100
100
100
100
100
100
100
-
-
-
50
50
50
50
1 - 1.6
1.6 - 2.5
2.5 - 4
4 - 6.3
6.3 - 10
6.3 - 10
8 - 12
MSC-R-1,6-M7(230V50HZ)/BBA 102985
MSC-R-2,5-M7(230V50HZ)/BBA 102986
MSC-R-4-M7(230V50HZ)/BBA 102987
MSC-R-6,3-M7(230V50HZ)/BBA 102988
MSC-R-10-M7(230V50HZ)/BBA 102989
MSC-R-10-M9(230V50HZ)/BBA 102990
MSC-R-12-M12(230V50HZ)/BBA 102991
100
100
50
50
50
50
50
50
50
50
6.3 - 10
8 - 12
10 - 16
20 - 25
25 - 32
MSC-R-10-M17(230V50HZ)/BBA 102992
MSC-R-12-M17(230V50HZ)/BBA 102993
MSC-R-16-M17(230V50HZ)/BBA 102994
MSC-R-25-M25(230V50HZ)/BBA 102995
MSC-R-32-M32(230V50HZ)/BBA 102996
MSC-R-0,25-M7(24VDC)/BBA 102997
MSC-R-0,4-M7(24VDC)/BBA 102998
MSC-R-0,63-M7(24VDC)/BBA 102999
MSC-R-1-M7(24VDC)/BBA 103000
MSC-R-1,6-M7(24VDC)/BBA 103001
MSC-R-2,5-M7(24VDC)/BBA 103002
MSC-R-4-M7(24VDC)/BBA 103003
MSC-R-6,3-M7(24VDC)/BBA 103004
MSC-R-10-M7(24VDC)/BBA 103005
MSC-R-10-M9(24VDC)/BBA 103006
MSC-R-12-M12(24VDC)/BBA 103007
MSC-R-10-M17(24VDC)/BBA 103008
MSC-R-12-M17(24VDC)/BBA 103009
MSC-R-16-M17(24VDC)/BBA 103010
MSC-R-25-M25(24VDC)/BBA 103011
MSC-R-32-M32(24VDC)/BBA 103012
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 195
CA08103003Z_MOEM2015-EN.book Seite 195 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Motor-starter combinations
DOL starters/Reversing starter on busbar adapter
Motor-starter combinations DOL starters/Reversing starter on busbar adapter
Motor ratings
Rated short-circuit current
380 - 415 V
Type of coordination
Type of coordination
I
“1” q
I
“2” q kA kA
PKZ and DILM complete devices on BBA for DOL starters
100 50
100
50
50
50
100
100
50
100
100
100
100
100
100
100
100
100
50
50
50
50
-
-
-
50
50
50
-
50
50
50
50
50
I r
A
Setting range of overload releases
AC operation
230 V 50 Hz
Part no.
Article no.
0.16 - 0.25
MSC-D-0,25-M7(230V50HZ)/BBA 102737
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
MSC-D-0,4-M7(230V50HZ)/BBA
MSC-D-0,63-M7(230V50HZ)/BBA
MSC-D-1-M7(230V50HZ)/BBA
MSC-D-1,6-M7(230V50HZ)/BBA
102738
102739
102950
102951
1.6 - 2.5
2.5 - 4
4 - 6.3
6.3 - 10
6.3 - 10
8 - 12
10 - 16
6.3 - 10
8 - 12
10 - 16
20 - 25
25 - 32
MSC-D-2,5-M7(230V50HZ)/BBA
MSC-D-4-M7(230V50HZ)/BBA
MSC-D-6,3-M7(230V50HZ)/BBA
MSC-D-10-M7(230V50HZ)/BBA
MSC-D-10-M9(230V50HZ)/BBA
MSC-D-12-M12(230V50HZ)/BBA
MSC-D-16-M15(230V50HZ)/BBA
MSC-D-10-M17(230V50HZ)/BBA
MSC-D-12-M17(230V50HZ)/BBA
MSC-D-16-M17(230V50HZ)/BBA
MSC-D-25-M25(230V50HZ)/BBA
MSC-D-32-M32(230V50HZ)/BBA
102952
102953
102954
102955
102956
102957
102958
102959
102960
102961
102962
102963
DC operation
24 V DC
Part no.
Article no.
MSC-D-0,25-M7(24VDC)/BBA 102964
MSC-D-0,4-M7(24VDC)/BBA 102965
MSC-D-0,63-M7(24VDC)/BBA 102966
MSC-D-1-M7(24VDC)/BBA 102967
MSC-D-1,6-M7(24VDC)/BBA 102968
MSC-D-2,5-M7(24VDC)/BBA 102969
MSC-D-4-M7(24VDC)/BBA 102970
MSC-D-6,3-M7(24VDC)/BBA 102971
MSC-D-10-M7(24VDC)/BBA 102972
MSC-D-10-M9(24VDC)/BBA 102973
MSC-D-12-M12(24VDC)/BBA 102974
MSC-D-16-M15(24VDC)/BBA 102975
MSC-D-10-M17(24VDC)/BBA 102976
MSC-D-12-M17(24VDC)/BBA 102977
MSC-D-16-M17(24VDC)/BBA 102978
MSC-D-25-M25(24VDC)/BBA 102979
MSC-D-32-M32(24VDC)/BBA 102980
PKZ and DILM complete devices on BBA for reversing starters
100
100
100
100
50
50
50
50
0.16 - 0.25
MSC-R-0,25-M7(230V50HZ)/BBA 102981
0.25 - 0.4
MSC-R-0,4-M7(230V50HZ)/BBA 102982
0.4 - 0.63
0.63 - 1
MSC-R-0,63-M7(230V50HZ)/BBA
MSC-R-1-M7(230V50HZ)/BBA
102983
102984
100
100
100
100
100
100
100
-
-
-
50
50
50
50
1 - 1.6
1.6 - 2.5
2.5 - 4
4 - 6.3
6.3 - 10
6.3 - 10
8 - 12
MSC-R-1,6-M7(230V50HZ)/BBA 102985
MSC-R-2,5-M7(230V50HZ)/BBA 102986
MSC-R-4-M7(230V50HZ)/BBA 102987
MSC-R-6,3-M7(230V50HZ)/BBA 102988
MSC-R-10-M7(230V50HZ)/BBA 102989
MSC-R-10-M9(230V50HZ)/BBA 102990
MSC-R-12-M12(230V50HZ)/BBA 102991
100
100
50
50
50
50
50
50
50
50
6.3 - 10
8 - 12
10 - 16
20 - 25
25 - 32
MSC-R-10-M17(230V50HZ)/BBA 102992
MSC-R-12-M17(230V50HZ)/BBA 102993
MSC-R-16-M17(230V50HZ)/BBA 102994
MSC-R-25-M25(230V50HZ)/BBA 102995
MSC-R-32-M32(230V50HZ)/BBA 102996
MSC-R-0,25-M7(24VDC)/BBA 102997
MSC-R-0,4-M7(24VDC)/BBA 102998
MSC-R-0,63-M7(24VDC)/BBA 102999
MSC-R-1-M7(24VDC)/BBA 103000
MSC-R-1,6-M7(24VDC)/BBA 103001
MSC-R-2,5-M7(24VDC)/BBA 103002
MSC-R-4-M7(24VDC)/BBA 103003
MSC-R-6,3-M7(24VDC)/BBA 103004
MSC-R-10-M7(24VDC)/BBA 103005
MSC-R-10-M9(24VDC)/BBA 103006
MSC-R-12-M12(24VDC)/BBA 103007
MSC-R-10-M17(24VDC)/BBA 103008
MSC-R-12-M17(24VDC)/BBA 103009
MSC-R-16-M17(24VDC)/BBA 103010
MSC-R-25-M25(24VDC)/BBA 103011
MSC-R-32-M32(24VDC)/BBA 103012
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 196 Donnerstag, 7. April 2016 12:02 12
Motor-starter combinations
Electronic motor starter
Motor-starter combinationsElectronic motor starter
Description
Moeller® series
Max. rating for three-phase motors,
50 - 60 Hz
AC-53a
380 V 400 V 415 V
P kW
I r
A
Setting range of overload releases
DC operation
24 V DC
Part no.
EMS complete devices
DOL starting, Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
DOL starting, Motor protection, Emergency-stop actuator
Circuit design: safety output stage with bypass, three-phase disconnect.
0.06 - 0.75
0.55 - 3
0.06 - 0.75
0.55 - 3
Article no.
0,18 - 2,4
1,5 - 6,5 (AC-53a)
9 (AC-51)
0,18 - 2,4
1,5 - 6,5 (AC-53a)
9 (AC-51)
EMS-DO-T-2,4-24VDC
EMS-DO-T-9-24VDC
EMS-DOS-T-2,4-24VDC
EMS-DOS-T-9-24VDC
170099
170100
170103
170104
DOL starting
Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
For connecting to SmartWire-DT for expanded diagnostics.
DOL starting
Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
Controlled stop via additional enable signal terminal up to SIL3/Ple.
For connecting to SmartWire-DT for expanded diagnostics.
DOL starting, Reversing start, Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
DOL starting, Reversing start, Motor protection,
Emergency-stop actuator
Circuit design: safety output stage with bypass, three-phase disconnect.
0.06 - 0.75
0.55 - 3
0.06 - 0.75
0.55 - 3
0.06 - 0.75
0.55 - 3
0.06 - 0.75
0.55 - 3
0,18 - 2,4
1,5 - 7 (AC-53a)
9 (AC-51)
EMS-DO-T-2,4-SWD
EMS-DO-T-9-SWD
170106
170107
0,18 - 2,4
1,5 - 7 (AC-53a)
9 (AC-51)
EMS-DOS-T-2,4-SWD
EMS-DOS-T-9-SWD
170110
170111
0,18 - 2,4
1,5 - 6,5 (AC-53a)
9 (AC-51)
0,18 - 2,4
1,5 - 6,5 (AC-53a)
9 (AC-51)
EMS-RO-T-2,4-24VDC
EMS-RO-T-9-24VDC
EMS-ROS-T-2,4-24VDC
EMS-ROS-T-9-24VDC
170101
170102
170105
169789
DOL starting
Reversing start
Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
For connecting to SmartWire-DT for expanded diagnostics.
DOL starting
Reversing start
Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
Controlled stop via additional enable signal terminal up to SIL3/Ple.
For connecting to SmartWire-DT for expanded diagnostics.
0.06 - 0.75
0.55 - 3
0.06 - 0.75
0.55 - 3
0,18 - 2,4
1,5 - 7 (AC-53a)
9 (AC-51)
EMS-RO-T-2,4-SWD
EMS-RO-T-9-SWD
170108
170109
0,18 - 2,4
1,5 - 7 (AC-53a)
9 (AC-51)
EMS-ROS-T-2,4-SWD
EMS-ROS-T-9-SWD
170112
169790
CA08103003Z_MOEM2015-EN.book Seite 197 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Motor-starter combinationsAccessories
Pole
Three-phase current connector with plug
3
Connection links
3
4
5
2
3
10
2
3
4
5
Devices
Number
Motor-starter combinations
Accessories
For use with Part no.
Article no.
EMS-D...
EMS-D…-SWD-…
EMS-R...
EMS-R…-SWD-…
EMS-XBR3-2
EMS-XBR3-3
EMS-XBR3-4
EMS-XBR3-5
177248
177249
177250
177251
EMS-D...
EMS-D…-SWD-…
EMS-R...
EMS-R…-SWD-…
EMS-XBR-2
EMS-XBR-3
EMS-XBR-4
EMS-XBR-5
EMS-XBR-10
171268
171269
171270
171271
171272
1 2
3
4
5
EMS-D...
EMS-DOS…-SWD-…
EMS-R...
EMS-ROS…-SWD-…
EMS-XCW-2
EMS-XCW-3
EMS-XCW-4
EMS-XCW-5
172741
172742
172743
172744
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 197
CA08103003Z_MOEM2015-EN.book Seite 197 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Motor-starter combinationsAccessories
Pole
Three-phase current connector with plug
3
Connection links
3
4
5
2
3
10
2
3
4
5
Devices
Number
Motor-starter combinations
Accessories
For use with Part no.
Article no.
EMS-D...
EMS-D…-SWD-…
EMS-R...
EMS-R…-SWD-…
EMS-XBR3-2
EMS-XBR3-3
EMS-XBR3-4
EMS-XBR3-5
177248
177249
177250
177251
EMS-D...
EMS-D…-SWD-…
EMS-R...
EMS-R…-SWD-…
EMS-XBR-2
EMS-XBR-3
EMS-XBR-4
EMS-XBR-5
EMS-XBR-10
171268
171269
171270
171271
171272
1 2
3
4
5
EMS-D...
EMS-DOS…-SWD-…
EMS-R...
EMS-ROS…-SWD-…
EMS-XCW-2
EMS-XCW-3
EMS-XCW-4
EMS-XCW-5
172741
172742
172743
172744
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
DS7
S801+ / S811+
DS7, S801+ and S811+ soft starter a soft start for any task
U
U
-Start t
-Start t
-Stop
Soft starters make it possible to perfectly adapt motors to any application, as well as to configure stop functions and a start voltage.
t
The soft starter has become increasingly established as an alternative to the star-delta starter. Electronic soft starter fulfil the customer demand for an impact free rise in torque and a determined reduction in current during the start phase. You control the power supply of the three-phase motor in the start phase so that the motor matches the load behaviour of the load machine. The mechanical equipment is accelerated with the minimum of stress as a result. The operating behaviour and the work processes are influenced positively which means that negative influences are avoided.
With its DS7 devices for currents of up to 200 A and S801+/S811+ devices for currents of up to 1,700 A, Eaton offers two different soft starter series with different strengths: DS7 units are ideal for standard applications, while S811+ models make a compelling case with their powerful range of functionalities.
www.eaton.eu/softstarters
198 EATON CA08103003Z-EN-INT
DS7 soft starters – soft starting and powerful torque all in one
Soft starters have become increasingly popular as an alternative to the star-delta starter. DS7 units not only replace the mechanical contactor, but also add a “soft motor startup” function to it. A patented method ensures that motor run-ups will be exceptionally soft while providing a higher torque than other available solutions. Longer service intervals and reduced operating costs are welcome side effects of this. DS7 compact soft starters are designed for normal applications, such as those involving pumps, fans, and small conveyor belts.
Application examples
• Three-phase inductive loads
• Noiseless and soft motor start in transport and conveying systems
• Soft starting of pumps reduces the load on the entire installation (water impact)
• Solid-state switching of pumps in the extreme environments of chemical plants and filling stations
• Smooth start that reduces wear on V-belts in fan drives.
S801+/S811+ soft starters – a powerful presence in a small design
These three-phase-controlled soft starters, which feature an internal bypass and comprehensive monitoring and protection mechanisms, provide a soft start and ensure that threephase motors can remain safely in continuous operation even in applications with large load torques. In addition, they can be used not only in a standard line (outside the delta) configuration, but also with inside-the-delta connection. S801+ soft starters have been specifically designed for standard applications and make a strong case with their ease of use, while
S811+ devices feature a digital control and display unit that provides access to advanced functions for sophisticated applications. With only five sizes and rated operational currents of
37 A to 1,000 A for mains voltages of 200 V to 690 V, S801+ and S811+ units are some of the world’s smallest compact soft starters.
Current characteristic in the uncontrolled phase
Conventional methods:
Symmetrical control with high level of DC components
New process from Eaton:
Asymmetric control without DC components
Asymmetric control: It does not get any softer
The special starting method (asymmetrical trigger control) for the soft starter function prevents DC components that normally occur with a two-phase controlled starter (Eaton patent). They suppress the formation of an elliptical rotating field, which leads to an irregular acceleration of the motor and unnecessarily extends acceleration times. The smooth starting behaviour of the DS7 is thus similar to that of a three-phase soft starter.
DS7 soft starters with SmartWire-DT ® – Direct access to all parameters
Being able to use a controller to directly access all of a soft starter’s parameters via SmartWire-DT is the epitome of ease of operation. Users can read and overwrite potentiometer settings. Extended status, error, and diagnostic messages can be retrieved directly. The result: absolute data transparency.
The plug-in units make installation fast and foolproof, and the resulting connection includes the soft starter’s control current supply.
Advantages:
• Reduced I/O level
• Plug-in control wiring prevents wiring errors
• Integrated solution does not require any additional options
EATON CA08103003Z-EN-INT 199
CA08103003Z_MOEM2015-EN.book Seite 200 Donnerstag, 7. April 2016 12:02 12
Soft starters
DS7 < 32 A system overview
18
17
19
13
5
7
15
14
10
13
9
6
7
1
4
16
20
21
2
12
4
22
23
3
11
4
24
25
Moeller® series
CA08103003Z_MOEM2015-EN.book Seite 201 Donnerstag, 7. April 2016 12:02 12
4
5
1
8
8
7
6
5
4
3
2
1
9, 10
11
12
13
DS7 < 32 A system overview
Soft starter DS7 with SmartWire-DT
DS7 soft starters in construction size 1 for assigned motor current up to 12 A
DS7 soft starters in construction size 2 for assigned motor current up to 32 A
Device fan (DS7-FAN-32)
SmartWire-DT gateway
SmartWire-DT external device plug
SmartWire-DT flat band conductor
Overload relay
PKZM0-XDM wiring set in tool-less plug connection
PKZM0-XM wiring set
Three-phase commoning link
Standard auxiliary contacts
18
19
20
21
14
15
16
17
22
23
24
25
Early-make auxiliary contact
Door coupling handle
PKZM0 motor-protective circuit-breakers
PKE motor-protective circuit-breakers
Connection clamp
Voltage release
Trip indicator
Standard auxiliary contacts
Motor-starter combination with PKZ
Motor-starter combination with PKE
Busbar adapter
Top-hat rail adapter
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
2
1
4
3
5
S811+ system overview
Soft starter S811+
Fuse bases and fuses
Connection terminals
Fieldbus connection
Operating unit
2
EATON CORPORATION CA08103003Z-EN
3
Soft starters
S811+ system overview
201
CA08103003Z_MOEM2015-EN.book Seite 201 Donnerstag, 7. April 2016 12:02 12
2
Soft starters
S811+ system overview
5
1
3
4
2
1
4
3
5
S811+ system overview
Soft starter S811+
Fuse bases and fuses
Connection terminals
Fieldbus connection
Operating unit
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
81
100
135
160
32
41
55
70
200
4
7
9
12
16
24
Notes
CA08103003Z_MOEM2015-EN.book Seite 202 Donnerstag, 7. April 2016 12:02 12
Soft starters
DS7
DS7
I e
A
Rated operational current device
(AC-53)
Assigned motor rating at 400 V, 50 Hz
P kW at 460 V, 60 Hz
P
HP
100
135
160
32
41
55
70
81
200
4
7
9
12
16
24
Soft starters
Soft starters for three-phase loads
Mains supply voltage (50/60 Hz)
U
LN
200 - 480 V AC
55
75
90
15
22
30
37
45
110
1.5
3
4
5.5
7.5
11
75
100
125
25
30
40
50
60
150
2
5
5
10
10
15
45
55
75
90
15
22
30
37
110
1.5
3
4
5.5
7.5
11
60
75
100
125
25
30
40
50
150
2
5
5
10
10
15
Part no.
U
C
U s
24 V AC/DC
24 V AC/DC
Standard temperature range
Moeller® series
Article no.
Article no.
Part no.
U
C
U s
24 V AC/DC
24 V AC/DC
Expanded temperature range down to -40 °C
DS7-340SX004N0-N
DS7-340SX007N0-N
DS7-340SX009N0-N
DS7-340SX012N0-N
DS7-340SX016N0-N
DS7-340SX024N0-N
DS7-340SX032N0-N
DS7-340SX041N0-N
DS7-340SX055N0-N
DS7-340SX070N0-N
DS7-340SX081N0-N
DS7-340SX100N0-N
DS7-340SX135N0-N
DS7-340SX160N0-N
DS7-340SX200N0-N
U
C
U s
110 - 230 V AC
110 - 230 V AC
DS7-342SX004N0-N
DS7-342SX007N0-N
DS7-342SX009N0-N
DS7-342SX012N0-N
DS7-342SX016N0-N
DS7-342SX024N0-N
DS7-342SX032N0-N
DS7-342SX041N0-N
DS7-342SX055N0-N
DS7-342SX070N0-N
DS7-342SX081N0-N
DS7-342SX100N0-N
DS7-342SX135N0-N
DS7-342SX160N0-N
DS7-342SX200N0-N
134932
134934
134935
134936
134937
134938
134939
134940
134941
134925
134927
134928
134929
134930
134931
134914
134916
134917
134918
134919
134920
134921
134922
134923
134847
134849
134910
134911
134912
134913
DS7-340SX004N0-L
DS7-340SX007N0-L
DS7-340SX009N0-L
DS7-340SX012N0-L
DS7-340SX016N0-L
DS7-340SX024N0-L
DS7-340SX032N0-L
DS7-340SX041N0-L
DS7-340SX055N0-L
DS7-340SX070N0-L
DS7-340SX081N0-L
DS7-340SX100N0-L
DS7-340SX135N0-L
DS7-340SX160N0-L
DS7-340SX200N0-L
U
C
U s
24 V DC
24 V DC
DS7-34DSX004N0-D
DS7-34DSX007N0-D
DS7-34DSX009N0-D
DS7-34DSX012N0-D
DS7-34DSX016N0-D
DS7-34DSX024N0-D
DS7-34DSX032N0-D
DS7-34DSX041N0-D
DS7-34DSX055N0-D
DS7-34DSX070N0-D
DS7-34DSX081N0-D
DS7-34DSX100N0-D
DS7-34DSX135N0-D
DS7-34DSX160N0-D
DS7-34DSX200N0-D
134950
134952
134953
134954
134955
134956
134957
134958
134959
134943
134945
134946
134947
134948
134949
171746
171747
171748
171749
171750
171751
171752
171753
171754
171740
171741
171742
171743
171744
171745
CA08103003Z_MOEM2015-EN.book Seite 203 Donnerstag, 7. April 2016 12:02 12
DS7 Accessories, S811+
For use with
Device fans
Device fan for increasing the load cycle (more starts per hour higher or longer-lasting starting current)
Flush-mounted fan DS7-34…SX004…
DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…
DS7-34…SX016…
DS7-34…SX024…
Bottom fans
DS7-34…SX032…
DS7-34…SX041…
DS7-34…SX055…
DS7-34…SX070…
DS7-34…SX081…
DS7-34…SX100…
DS7-34…SX135…
DS7-34…SX160…
DS7-34…SX200…
Part no.
DS7-FAN-032
DS7-FAN-100
DS7-FAN-200
Frame size
I e
A
Rated operational current
AC-53
Assigned motor rating at 230 V,
50 Hz kW at 230 V,
60 Hz
HP
Soft starters S811+
Soft starter for three-phase loads, with control unit
Mains supply voltage (50/60 Hz) U
LN
: 200 - 600 V AC
In-line configuration/In-delta configuration
Supply voltage U s
: 24 V DC
Control voltage U
C
: 24 V DC
With internal bypass contacts
Terminal blocks for the terminals are required for frame sizes T, U, and V -> Accessories
N 37 7.5
10
66 18.5
20
R
T
U
V
105
135
180
240
304
361
420
361
420
500
650
720
850
1000
30
37
55
75
90
110
132
-
-
110
132
160
200
250
40
50
60
75
100
125
150
-
-
125
150
200
-
250
Notes
Sizes S811+ at 400 V,
50 Hz kW
200
200
200
200
250
315
400
450
560
90
132
160
18.5
30
55
75 at 460 V,
60 Hz
HP
300
350
300
350
400
500
600
600
750
150
200
250
25
50
75
100
Part no.
S811+N37N3S
S811+N66N3S
S811+R10N3S
S811+R13N3S
S811+T18N3S
S811+T24N3S
S811+T30N3S
S811+U36N3S
S811+U42N3S
S811+V36N3S
S811+V42N3S
S811+V50N3S
S811+V65N3S
S811+V72N3S
S811+V85N3S
S811+V10N3S
Soft starters
DS7 Accessories, S811+
Article no.
135553
169021
169022
Article no.
168976
168978
168980
168982
168984
168987
168990
169869
169870
168993
168996
168999
169002
169005
169008
169011
4 - 12 A 16 - 32 A 41 - 100 A 135 -200 A
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
N R T U V
EATON CORPORATION CA08103003Z-EN 203
CA08103003Z_MOEM2015-EN.book Seite 203 Donnerstag, 7. April 2016 12:02 12
DS7 Accessories, S811+
For use with
Device fans
Device fan for increasing the load cycle (more starts per hour higher or longer-lasting starting current)
Flush-mounted fan DS7-34…SX004…
DS7-34…SX007…
DS7-34…SX009…
DS7-34…SX012…
DS7-34…SX016…
DS7-34…SX024…
Bottom fans
DS7-34…SX032…
DS7-34…SX041…
DS7-34…SX055…
DS7-34…SX070…
DS7-34…SX081…
DS7-34…SX100…
DS7-34…SX135…
DS7-34…SX160…
DS7-34…SX200…
Part no.
DS7-FAN-032
DS7-FAN-100
DS7-FAN-200
Frame size
I e
A
Rated operational current
AC-53
Assigned motor rating at 230 V,
50 Hz kW at 230 V,
60 Hz
HP
Soft starters S811+
Soft starter for three-phase loads, with control unit
Mains supply voltage (50/60 Hz) U
LN
: 200 - 600 V AC
In-line configuration/In-delta configuration
Supply voltage U s
: 24 V DC
Control voltage U
C
: 24 V DC
With internal bypass contacts
Terminal blocks for the terminals are required for frame sizes T, U, and V -> Accessories
N 37 7.5
10
66 18.5
20
R
T
U
V
105
135
180
240
304
361
420
361
420
500
650
720
850
1000
30
37
55
75
90
110
132
-
-
110
132
160
200
250
40
50
60
75
100
125
150
-
-
125
150
200
-
250
Notes
Sizes S811+ at 400 V,
50 Hz kW
200
200
200
200
250
315
400
450
560
90
132
160
18.5
30
55
75 at 460 V,
60 Hz
HP
300
350
300
350
400
500
600
600
750
150
200
250
25
50
75
100
Part no.
S811+N37N3S
S811+N66N3S
S811+R10N3S
S811+R13N3S
S811+T18N3S
S811+T24N3S
S811+T30N3S
S811+U36N3S
S811+U42N3S
S811+V36N3S
S811+V42N3S
S811+V50N3S
S811+V65N3S
S811+V72N3S
S811+V85N3S
S811+V10N3S
Soft starters
DS7 Accessories, S811+
Article no.
135553
169021
169022
Article no.
168976
168978
168980
168982
168984
168987
168990
169869
169870
168993
168996
168999
169002
169005
169008
169011
N R
Complete assortment -> www.eaton.eu/ecat
T U
EATON CA08103003Z-EN-INT
V
PowerXL™: The right drive for each application
Our customers have a wide range of requirements that is only matched by the wide range of devices and functionalities in Eaton's range of high-efficiency drives engineering products – from starting motors in simple machines to speed control for complex applications and heavy loads.
In fact, the PowerXL™ and 9000X* device families cover every single application from variable speed starters to liquid-cooled variable frequency drives. Especially now that the PowerXL family has been expanded with two impressive new additions: the extremely efficient DE1 variable speed starter and the general-purpose DG1 variable frequency drive.
Catalog download: www.eaton.eu/catalog
* For more detailed information on 9000X variable frequency drives, please refer to our product range catalog.
www.eaton.eu/powerxl
PowerXL™ selection aid
Simple planning and engineering
An electronic selection aid provides simple planning, helping you quickly select the drive required for your application and the associated switchgear, protective elements, chokes, and filters complete with the corresponding article number. www.eaton.eu/selectiontools
204 EATON CA08103003Z-EN-INT
PowerXL™ DE1/DE11 variable speed starters
PowerXL™ DE1/DE11 variable speed starters combine ease of use and maximum reliability with variable motor speeds and improved machine energy efficiency. With them, Eaton offers a device class that closes the gap between conventional motor starters and variable frequency drives while combining all the advantages of both in a single unit. The DE11 is the latest addition to this product range, and adds CANopen, plug-in control signal terminals, and a configurable output relay to the list of features already found in its predecessor.
Performance range:
• 0.25 … 2.2 kW (Ue: 1~ 230 V, U2: 3~ 230 V)
• 0.37 … 7.5 kW (Ue: 3~ 400 V, U2: 3~ 400 V)
Features:
• Compact: 45-mm width
• Out-of-the-box commissioning without parameterization
• No special drives engineering skills or knowledge required
• Screwdriver parameterization can be set with DXE-EXT-
SET optional configuration module
• Trip-free-design ensures maximum machine availability
• Suitable for use in ambient temperatures of up to 60 °C
• International standards (CE, UL, cUL, cTick, RoHS)
• DE11: CANopen, plug-in control signal terminals, configurable output relay
Commissioning
As easy to use as a motor starter
No special knowledge of drives is required for the new DE1 Variable Speed Starter – either for installation or commissioning. The compact Variable Speed Starter is as easy and convenient to use as a conventional motor starter.
The device is unpacked and simply wired like a motor starter – that's it. The DE1 Variable Speed
Starter is ready to go. It couldn't be easier! In addition, the "out-of-the-box comissioning" reduces the chances of installation faults to a minimum and at the same time it makes installation faster and more cost-efficient!
1 2 3 4
Snap the variable speed starter on the DIN-Rail.
Connect mains and motor cables.
Wire control terminals.
Parameterization by screwdriver
DXE-EXT-SET (plug-in configuration module)
Beyond the out-of-the-box commissioning that eliminates the need for parameterization, the user also has the option of using the plug-in DXE-EXT-SET configuration module to adjust the default settings of key parameters such as ramp time, motor protection and control terminal function to fit the current application. All that is needed is a screwdriver.
Switch on and the motor runs with its speed controlled.
EATON CA08103003Z-EN-INT 205
PowerXL™ DC1 variable frequency drives – Compact machinery drive
The compact PowerXL™ variable frequency drive is particularly well-suited for use with simple pump, fan, and conveyor belt systems. It can be quickly and easily configured and commissioned, resulting in tangible savings.
Performance range:
• 0.37 … 0.55 kW (Ue: 1~ 115 V, U2: 1~ 115 V)
• 0.37 … 1.1 kW (Ue: 1~ 115 V, U2: 3~ 230 V)
• 0.37 … 1.1 kW (Ue: 1~ 230 V, U2: 1~ 230 V)
• 0.37 … 4 kW (Ue: 1~ 230 V, U2: 3~ 230 V)
• 0.37 … 11 kW (Ue: 3~ 230 V, U2: 3~ 230 V)
• 0.75 … 22 kW (Ue: 3~ 400 V, U2: 3~ 400 V)
Features:
• Fast commissioning with 14 basic parameters
• Large overload capability: 150% for 60 seconds, 175% for 2 seconds
• Ambient air temperature up to 50 °C without derating
• Integrated CANopen and Modbus RTU
• Degrees of protection IP20 and IP66
• Integrated EMC filter
• Integrated braking transistor
• Integrated PI controller
• V/F control
• Voltage boost
• DC braking
• Detachable control signal terminal strip
• International standards (CE, UL, cUL, c-Tick, RoHS, EAC,
UkrSEPRO)
Simply use a COM stick to copy parameter configurations
Our communications stick makes it possible to quickly and easily transfer parameters from your laptop to PowerXL variable frequency drives using Bluetooth. The convenience of this feature is only matched by the stick’s copy function, which can be used to transfer parameters from one variable frequency drive to another.
Communicate like never before
Our new variable frequency drives also come with the latest in communication features, including a CANopen and Modbus
RTU interface as standard. In addition, DA1 drives can also be connected to Ethernet-based protocols (PROFINET,
Ethernet/IP, EtherCAT, Modbus TCP, BACnet/IP), the widespread PROFIBUS, and, for American markets, DeviceNet.
206
50 °C
EATON CA08103003Z-EN-INT
No derating at 50 °C
All DE1, DC1, and DA1 IP20 devices are able to work at an ambient air temperature of 50 °C without derating, i.e., the units can be operated at their rated current even under these conditions. In addition, the option of installing the devices side by side ensures that the space inside your control panel will be used as efficiently as possible.
The advantages:
• Optimized control cabinet configuration
• Eliminates the costs of additional ventilation/cooling
PowerXL™ DA1 variable frequency drive – Advanced machinery drive
The PowerXL™ DA1 variable frequency drive, designed for the machine and system building industry, is characterized by its enormous flexibility in terms of communications protocols, a function block editor (PLC) that makes it possible to configure the drive as necessary for specific applications, and a powerful vector control mode for highly dynamic applications.
Performance range:
• 0.75 … 2.2 kW (Ue: 1~ 230 V, U2: 3~ 230 V)
• 0.75 … 75 kW (Ue: 3~ 230 V, U2: 3~ 230 V)
• 0.75 … 250 kW (Ue: 3~ 400 V, U2: 3~ 400 V)
• 0.75 … 110 kW (Ue: 3~ 575 V, U2: 3~ 575 V)
Features:
• Large overload capability: 150 % for 60 seconds, 200 % for 4 seconds.
• Integrated Modbus RTU and CANopen
• Ambient air temperature up to 50 °C without derating
• Integrated EMC filter
• Integrated braking transistor
• Various I/O expansions
• V/F control, vector SL and CL, PM motors, BLDC motors,
SynRel motors
• Optional field bus connections
• Safe Torque Off (STO, SIL 2/Pl d)
• Optional high-resolution OLED display
• International standards (CE, UL, cUL, c-Tick, RoHS,
EAC, UkrSEPRO, DNV)
The built-in STO (Safe Torque Off) safety function
The Safe Torque-Off (STO) function is how the most fundamental drive-integrated safety function is implemented in the DA1, ensuring that torque will be fully removed from the motor and preventing accidental starts. This also eliminates the need for an additional mains contactor.
High communications flexibility
The new DE1 series comes with Modbus RTU as its integrated default communications protocol, while the DC1 and DA1 series come with the CANopen protocol already integrated at the factory. Moreover, all the variable frequency drives in these three series can be expanded with SmartWire-DT modules. Smart-
Wire-DT can be used with cyclic and acyclic services in order to control, configure and diagnose these drives by using the corresponding PROFIdrive profile. In addition, the DA1 series specifically comes with an expansion slot that can be used to expand its communication capabilities with a PROFIBUS, PROFINET, Ethernet/IP, EtherCAT, DeviceNet, or Modbus/TCP plug-in module.
Finally, there are function blocks available for connecting DE1,
DC1, and DA1 devices to PLCs or HMIs.
Function block editor – Simple programming
The function block editor can be used to create separate logic operations for the DA1 – with time dependencies, for example
- within the variable frequency drive in order to generate original applications. This makes it possible to configure the variable frequency drive for any application, cutting down on additional hardware costs in the process.
EATON CA08103003Z-EN-INT 207
PowerXL™ DG1variable frequency drive – General purpose drive
PowerXL™ DG1 multi-purpose drives are variable frequency drives belonging to Eaton's next-generation PowerXL™ series.
They are specifically designed for modern, sophisticated applications: In fact, a patented energy-saving algorithm, high short-circuit specifications, and a heavy-duty design all enable them to provide maximum efficiency, safety, and reliability
– all combined with a conformal coating designed to provide protection against aggressive environments.
Performance range::
• 0.75 … 90/132 kW (Ue: 3~ 230 V, U2: 3~ 230 V)
• 0.75 … 160 kW (Ue: 3~ 400 V, U2: 3~ 400 V)
• 1.5 … 150 kW (Ue: 3~ 575 V, U2: 3~ 575 V)
• Dual Rating (150% and 110% overload)
Features:
• Can be used within a temperature range of -30 °C to
+50 °C (60 °C with derating)
• STO
• Internal EMC filter (C2)
• Internal DC link choke (5%)
• On Board:
– Extensive I/O: 8 DIs, 1 DO, 3 ROs, 2 AIs, 2 AOs
– 2 expansion slots
– Internal braking chopper (with the option of not having one for 61 A and higher)
– Modbus RTU&TCP, Bacnet MSTP and Ethernet IP
• All sizes available in IP21 and IP54
• LCD graphic display
• Real-time clock (with battery backup)
Can be flexibly configured as required for your application:
• 4 applications with custom-tailored parameter sets
• Comprehensive monitor functions: 43 monitor values
• 2 PID
• Comprehensive multi-pump functionality (single master, multi-master, multi-follower, time control)
Expandable:
• Profibus
• In brief:
– Profinet, SWD, CANopen, DeviceNet
IO expansions
• Digital IO (3DI, 3DO, 1 thermistor)
• Analog IO (1AI, 2AO)
• Digital IO 240V (6DI)
• Relay board (3RO)
• PT100 board (3PT100)
Flange mounting
Global acceptance:
• CE, UL, cUL, C-Tick, EAC, UkrSepro, RoHS
The same ease of use as in all other PowerXL variable frequency drives
Startup Wizard with standard parameters just like in DC1 and
DA1 units; efficient diagnostics; switching between local and remote operation; removable control panel with copy & paste functionality. Extensive I/O and on-board COM can be expanded further with two slots.
f max
RPM f min
P1 P2 P3
A t
Control algorithms for complex pump systems already integrated
The internal multi-pump functionality makes it possible to use the DG1 to control virtually any pump system without the need for any expansions. When the unit is used this way, its real-time clock controls the uniform use of all available pumps.
208
Power Xpert inControl
The new PC software platform for all future communicationcapable Eaton devices. It is designed to assist users with programming, control, and monitoring. The following functions are included: loading, saving, and printing parameter sets; setting setpoints; controlling the variable frequency drive.
Monitoring is done in text or graphic format.
Supported products as of this writing:
• PowerXL DG1 drives
• C445 overload relays
EATON CA08103003Z-EN-INT
PowerXL™ variable speed starters DE1, variable frequency drives DC1
System overview
DE1
7
1
2
1 DE1 variable speed starter
2 Radio interference suppression filter
3 Mains choke, motor choke, sine filter
4 SmartWire-DT module
5 Configuration module
6 Memory and Bluetooth communication stick
7 External keypad
DE1
3
6
5
Fixed Freq.
Mode
I Motor
4
8
DC1
2
1 DC1 variable frequency drives
2 Radio interference suppression filter
3 Mains choke, motor choke, sine filter
4 Braking resistance
5 Expansion modules
6 SmartWire-DT module
7 Memory and Bluetooth communication stick
8 External keypad
1
3
7
6
5
EATON CA08103003Z-EN-INT
4
209
CA08103003Z_MOEM2015-EN.book Seite 210 Donnerstag, 7. April 2016 12:02 12
PowerXL™ DA1, DG1 variable frequency drives
System overview
System overview
2
DA1
1
8
3
8
7
6
5
4
3
2
1 DA1 variable frequency drive
Radio interference suppression filter
Mains choke, motor choke, sine filter
Brake Resistor
SmartWire-DT module
Communication modules, expansion modules
Memory and Bluetooth communication stick
External keypad
4
7
6
5
7
6
5
4
3
2
1 DG1 Variable frequency drive
Mounting frame for push-through mounting
Radio interference suppression filter
Brake Resistor
Mains choke, motor choke, sine filter
Communication modules, expansion modules
Mounting frame for operating unit
DG1
7
1
2
3
4
EATON CA08103003Z-EN-INT
6
5
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 211 Donnerstag, 7. April 2016 12:02 12
Moeller® series
PowerXL™ variable speed starter
DE1/DE11, for three-phase motors 230 V/400 V, IP20
DE1/DE11, for three-phase motors 230 V/400 V, IP20
Rated operational current 1) Assigned motor rating 1), 2), 3) Radio interference suppression filter
Frame size Degree of
Protection
Part no.
Article no.
I e
A
5
6.6
8.5
11.3
16
P kW
P
HP
Mains voltage (50/60Hz) U
U e
= 1 phase / U
2
= 3 phase
LN
200 (-10%) - 240 (+10%) V
1.4
2.3
2.7
0.25
0.37
0.55
0.33
0.5
0.5
4.3
7
0.75
1.5
1
2
9.6
2.2
3
Mains voltage (50/60Hz) U
LN
U e
1.3
= 3 phase / U
2
= 3 phase
380 (-10%) - 480 (+10%) V
0.37
0.5
2.1
0.75
1
3.6
1.5
2.2
3
4
5.5
7.5
2
3
3
5
7.5
10
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
FS1
FS2
FS1
FS2
IP20/NEMA 0
IP20/NEMA 0
DE1-121D4FN-N20N
DE1-122D3FN-N20N
DE1-122D7FN-N20N
DE1-124D3FN-N20N
DE1-127D0FN-N20N
DE1-129D6FN-N20N
DE1-341D3FN-N20N
DE1-342D1FN-N20N
DE1-343D6FN-N20N
DE1-345D0FN-N20N
DE1-346D6FN-N20N
DE1-348D5FN-N20N
DE1-34011FN-N20N
DE1-34016FN-N20N
9.6
5
6.6
8.5
11.3
16
Mains voltage (50/60Hz) U
U e
= 1 phase / U
2
= 3 phase
LN
200 (-10%) - 240 (+10%) V
1.4
2.3
2.7
4.3
0.25
0.37
0.55
0.75
0.33
0.5
0.5
1
7 1.5
2
Notes
2.2
2.2
3
4
5.5
7.5
3
Mains voltage (50/60Hz) U
U e
= 3 phase / U
2
= 3 phase
LN
380 (-10%) - 480 (+10%) V
1.3
2.1
3.6
0.37
0.75
1.5
0.5
1
2
3
3
5
7.5
10
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
FS1
FS2
FS1
FS2
IP20/NEMA 0
IP20/NEMA 0
DE11-121D4FN-N20N 4) 180650
DE11-122D3FN-N20N 4) 180651
DE11-122D7FN-N20N 4) 180652
DE11-124D3FN-N20N 4) 180653
DE11-127D0FN-N20N 4) 180654
DE11-129D6FN-N20N 4) 180655
DE11-341D3FN-N20N
DE11-342D1FN-N20N
DE11-343D6FN-N20N
4)
4)
4)
180662
180663
180664
DE11-345D0FN-N20N 4) 180665
DE11-346D6FN-N20N 4) 180666
DE11-348D5FN-N20N 4) 180667
DE11-34011FN-N20N 4) 180668
DE11-34016FN-N20N 4) 180669
1) Overload cycle: 150 % for 60 s every 600 s
2) DE1/DE11-12…: at 230 V, 50 Hz/at 220 - 240 V, 60 Hz
3)
DE1/DE11-34…: at 400 V, 50 Hz/at 440 - 480 V, 60 Hz
For normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm -1 at 50 Hz or 1800 min -1 at 60 Hz
4) DE11… with additional features in comparison to DE1…: CANopen, plug-in control signal terminals, configurable output relay
174327
174328
174329
174330
174331
174332
174333
174334
174335
174336
174337
174338
174339
174340
DE1/DE11, FS1 DE1/DE11, FS2
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 212 Donnerstag, 7. April 2016 12:02 12
PowerXL™ variable frequency drives
DC1, for AC motors, 115 V/230 V, IP20
DC1, for AC motors, 115 V/230 V, IP20
Rated operational current 1) Assigned motor rating 1), 2), 3) Fitted with Frame size Degree of Protection Part no.
Moeller® series
Article no.
I e
A
P kW
P
HP
Mains voltage (50/60Hz) U
LN
U e
7
= 1 phase / U
2
= 1 phase
110 (-10%) - 115 (+10%) V
0.37
0.5
10.5
7
10.5
Notes
0.55
0.75
0.75
1
-
-
Mains voltage (50/60Hz) U
LN
U e
4.3
= 1 phase / U
2
= 1 phase
200 (-10%) - 240 (+10%) V
0.37
0.5
-
✓ -
-
-
✓ -
-
✓
✓ ✓
✓
✓
✓
✓
FS1
FS2
FS1
IP20/NEMA 0
IP20/NEMA 0
DC1-S17D0NN-A20N
DC1-S1011NB-A20N
DC1-S24D3NN-A20N
DC1-S24D3FN-A20N
DC1-S27D0NN-A20N
DC1-S27D0FN-A20N
1.1
1.5
✓ ✓
✓ ✓ ✓
FS2 DC1-S2011NB-A20N
DC1-S2011FB-A20N
1)
2)
3)
Overload cycle: 150 % for 60 s every 600 s
DC1-S1…: at 115 V, 50 Hz/at 110 - 120 V, 60 Hz
DC1-S2…: at 230 V, 50 Hz/at 220 - 240 V, 60 Hz
For AC motors with internal and external ventilation with 50/60 Hz without additional start capacitor
169497
169500
169512
169521
169515
169524
169518
169527
DC1, FS1 DC1, FS2 DC1, FS3 DC1, FS4
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 213 Donnerstag, 7. April 2016 12:02 12
Moeller® series
DC1, for three-phase motors 230 V/400 V, IP20
Rated operational current 1) Assigned motor rating 1), 2), 3) Fitted with Frame size
PowerXL™ variable frequency drives
DC1, for three-phase motors 230 V/400 V, IP20
Degree of Protection Part no.
Article no.
I e
A
P kW
P
HP
Mains voltage (50/60Hz) U
U e
110 (-10%) - 115 (+10%) V
The mains voltage of 115 V is raised to 230 V (output voltage) through an internal voltage double connection.
2.3
= 1 phase / U
2
= 3 phase
LN
0.37
0.5
✓ FS1 IP20/NEMA 0
4.3
0.75
1 ✓
FS2 5.8
4.3
1.1
0.75
1.5
1
-
Mains voltage (50/60Hz) U
LN
U e
2.3
= 1 phase / U
2
= 3 phase
200 (-10%) - 240 (+10%) V
0.37
0.5
-
✓ -
-
-
✓ -
-
✓ ✓
✓
✓
✓
✓
FS1 IP20/NEMA 0
7
10.5
2.2
3
-
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
✓ ✓ 15 4 5
Mains voltage (50/60Hz) U
U e
= 3 phase / U
2
= 3 phase
LN
380 (-10%) - 480 (+10%) V
2.2
0.75
1 -
✓ -
✓
✓
4.1
5.8
1.5
1.5
2.2
2
2
3
-
✓ -
-
-
✓ -
-
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
✓
✓
✓
✓
FS2
FS3
FS1
FS2
IP20/NEMA 0
9.5
4 5
Mains voltage (50/60Hz) U
U e
= 3 phase / U
2
= 3 phase
LN
380 (-10%) - 480 (+10%) V
14 5.5
10 ✓ ✓
✓ ✓ ✓
18 7.5
✓ ✓
✓ ✓ ✓
24 11 15
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
30
39
46
Notes
15
18.5
22
20
25
30
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
FS3
FS4
IP20/NEMA 0
DC1-1D2D3NN-A20N
DC1-1D4D3NN-A20N
DC1-1D5D8NB-A20N
DC1-122D3NN-A20N
DC1-122D3FN-A20N
DC1-124D3NN-A20N
DC1-124D3FN-A20N
DC1-127D0NN-A20N
DC1-127D0FN-A20N
DC1-127D0NB-A20N
DC1-127D0FB-A20N
DC1-12011NB-A20N
DC1-12011FB-A20N
DC1-12015NB-A20N
DC1-342D2NN-A20N
DC1-342D2FN-A20N
DC1-344D1NN-A20N
DC1-344D1FN-A20N
DC1-344D1NB-A20N
DC1-344D1FB-A20N
DC1-345D8NB-A20N
DC1-345D8FB-A20N
DC1-349D5NB-A20N
DC1-349D5FB-A20N
DC1-34014NB-A20N
DC1-34014FB-A20N
DC1-34018NB-A20N
DC1-34018FB-A20N
DC1-34024NB-A20N
DC1-34024FB-A20N
DC1-34030NB-A20N
DC1-34030FB-A20N
DC1-34039NB-A20N
DC1-34039FB-A20N
DC1-34046NB-A20N
DC1-34046FB-A20N
169503
169506
169509
169453
169475
169456
169478
169459
169481
169462
169484
169465
169487
169222
169240
169225
169243
169228
169246
169231
169249
169234
169252
169237
169468
169490
169471
169493
169474
169496
180464
180461
180465
180462
180466
180463
1)
2)
3)
Overload cycle: 150 % for 60 s every 600 s
DC1-1D…, DC1-12…, DC1-32…: at 230 V, 50 Hz/at 220 - 240 V, 60 Hz
DC1-34…: at 400 V, 50 Hz/at 440 - 480 V, 60 Hz
For normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm -1 at 50 Hz or 1800 min -1 at 60 Hz
EATON CORPORATION CA08103003Z-EN 213
CA08103003Z_MOEM2015-EN.book Seite 213 Donnerstag, 7. April 2016 12:02 12
Moeller® series
DC1, for three-phase motors 230 V/400 V, IP20
Rated operational current 1) Assigned motor rating 1), 2), 3) Fitted with Frame size
PowerXL™ variable frequency drives
DC1, for three-phase motors 230 V/400 V, IP20
Degree of Protection Part no.
Article no.
I e
A
P kW
P
HP
Mains voltage (50/60Hz) U
U e
110 (-10%) - 115 (+10%) V
The mains voltage of 115 V is raised to 230 V (output voltage) through an internal voltage double connection.
2.3
= 1 phase / U
2
= 3 phase
LN
0.37
0.5
✓ FS1 IP20/NEMA 0
4.3
0.75
1 ✓
FS2 5.8
4.3
1.1
0.75
1.5
1
-
Mains voltage (50/60Hz) U
LN
U e
2.3
= 1 phase / U
2
= 3 phase
200 (-10%) - 240 (+10%) V
0.37
0.5
-
✓ -
-
-
✓ -
-
✓ ✓
✓
✓
✓
✓
FS1 IP20/NEMA 0
7
10.5
2.2
3
-
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
✓ ✓ 15 4 5
Mains voltage (50/60Hz) U
U e
= 3 phase / U
2
= 3 phase
LN
380 (-10%) - 480 (+10%) V
2.2
0.75
1 -
✓ -
✓
✓
4.1
5.8
1.5
1.5
2.2
2
2
3
-
✓ -
-
-
✓ -
-
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
✓
✓
✓
✓
FS2
FS3
FS1
FS2
IP20/NEMA 0
9.5
4 5
Mains voltage (50/60Hz) U
U e
= 3 phase / U
2
= 3 phase
LN
380 (-10%) - 480 (+10%) V
14 5.5
10 ✓ ✓
✓ ✓ ✓
18 7.5
✓ ✓
✓ ✓ ✓
24 11 15
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
30
39
46
Notes
15
18.5
22
20
25
30
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓ ✓
FS3
FS4
IP20/NEMA 0
DC1-1D2D3NN-A20N
DC1-1D4D3NN-A20N
DC1-1D5D8NB-A20N
DC1-122D3NN-A20N
DC1-122D3FN-A20N
DC1-124D3NN-A20N
DC1-124D3FN-A20N
DC1-127D0NN-A20N
DC1-127D0FN-A20N
DC1-127D0NB-A20N
DC1-127D0FB-A20N
DC1-12011NB-A20N
DC1-12011FB-A20N
DC1-12015NB-A20N
DC1-342D2NN-A20N
DC1-342D2FN-A20N
DC1-344D1NN-A20N
DC1-344D1FN-A20N
DC1-344D1NB-A20N
DC1-344D1FB-A20N
DC1-345D8NB-A20N
DC1-345D8FB-A20N
DC1-349D5NB-A20N
DC1-349D5FB-A20N
DC1-34014NB-A20N
DC1-34014FB-A20N
DC1-34018NB-A20N
DC1-34018FB-A20N
DC1-34024NB-A20N
DC1-34024FB-A20N
DC1-34030NB-A20N
DC1-34030FB-A20N
DC1-34039NB-A20N
DC1-34039FB-A20N
DC1-34046NB-A20N
DC1-34046FB-A20N
169503
169506
169509
169453
169475
169456
169478
169459
169481
169462
169484
169465
169487
169222
169240
169225
169243
169228
169246
169231
169249
169234
169252
169237
169468
169490
169471
169493
169474
169496
180464
180461
180465
180462
180466
180463
1)
2)
3)
Overload cycle: 150 % for 60 s every 600 s
DC1-1D…, DC1-12…, DC1-32…: at 230 V, 50 Hz/at 220 - 240 V, 60 Hz
DC1-34…: at 400 V, 50 Hz/at 440 - 480 V, 60 Hz
For normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm -1 at 50 Hz or 1800 min -1 at 60 Hz
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 214 Donnerstag, 7. April 2016 12:02 12
PowerXL™ variable frequency drives
DA1, for three-phase motors 230 V/400 V, IP20/IP55
DA1, for three-phase motors 230 V/400 V, IP20/IP55
Rated operational current 1) Assigned motor rating 1), 2), 3)
Fitted with Frame size Degree of
Protection
Part no.
Moeller® series
Article no.
I e
A
P kW
P
HP
240
302
370
450
90
110
150
180
202
30
39
46
61
72
18
24
4.1
5.8
9.5
14
Mains voltage (50/60Hz) U
LN
U e
4.3
= 1 phase / U
2
= 3 phase
200 (-10%) - 240 (+10%) V
0.75
1 ✓ ✓
7
10.5
1.5
2.2
2
3
✓
✓
✓
✓
Mains voltage (50/60Hz) U
LN
U e
2.2
= 3 phase / U
2
= 3 phase
380 (-10%) - 480 (+10%) V
0.75
1 ✓ ✓
1.5
2.2
4
5.5
7.5
11
5
10
2
3
10
15
132
160
200
250
45
55
75
90
110
30
37
15
18.5
22
200
250
300
350
20
25
30
40
50
60
75
100
150
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Notes
-
-
✓
✓
✓ -
-
✓
✓
✓ -
-
FS2 IP20/NEMA 0 DA1-124D3FB-A20C
DA1-127D0FB-A20C
DA1-12011FB-A20C
169078
169081
169084
-
-
-
-
-
-
-
-
-
✓
✓
✓
✓
✓
✓
✓
-
-
-
-
✓
✓
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
✓
✓
✓
✓
✓
✓
✓ -
-
-
-
-
-
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓ -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FS2
FS3
FS4
FS5
FS6
FS7
FS8
IP20/NEMA 0
DA1-34014FB-A20C
DA1-34018FB-A20C
DA1-34024FB-A20C
IP55/NEMA 12 DA1-34024FB-B55C
DA1-34030FB-B55C
DA1-34039FB-B55C
DA1-34046FB-B55C
DA1-34061FB-B55C
DA1-34072FB-B55C
DA1-34090FB-B55C
DA1-34110FB-B55C
DA1-34150FB-B55C
DA1-34180FB-B55C
IP20/NEMA 0
DA1-342D2FB-A20C
DA1-344D1FB-A20C
DA1-345D8FB-A20C
DA1-349D5FB-A20C
DA1-34202FB-B55C
DA1-34240FB-B55C
DA1-34302FB-B55C
DA1-34370FB-B20C
DA1-34450FB-B20C
169117
169120
169051
169054
169057
169060
169063
169390
169391
169392
169393
169394
169395
169397
169399
169401
169403
169405
169407
169217
169219
169221
1)
2)
3)
Overload cycle for 60 s every 600 s
DA1-12…: at 230 V, 50 Hz/at 220 - 240 V, 60 Hz
DA1-34…: at 400 V, 50 Hz/at 440 - 480 V, 60 Hz
For normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm -1 at 50 Hz or 1800 min -1 at 60 Hz
CA08103003Z_MOEM2015-EN.book Seite 215 Donnerstag, 7. April 2016 12:02 12
Moeller® series
DA1, for three-phase motors 230 V/400 V, IP20/IP55
PowerXL™ variable frequency drives
DA1, for three-phase motors 230 V/400 V, IP20/IP55
DA1, FS2 DA1, FS3 DA1, FS4 DA1, FS5
DA1, FS6 DA1, FS7 DA1, FS8
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 215
CA08103003Z_MOEM2015-EN.book Seite 215 Donnerstag, 7. April 2016 12:02 12
Moeller® series
DA1, for three-phase motors 230 V/400 V, IP20/IP55
PowerXL™ variable frequency drives
DA1, for three-phase motors 230 V/400 V, IP20/IP55
DA1, FS2 DA1, FS3 DA1, FS4 DA1, FS5
DA1, FS6 DA1, FS7 DA1, FS8
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 216 Donnerstag, 7. April 2016 12:02 12
PowerXL™ variable frequency drives
DG1, for three-phase motors 400 V, IP21
DG1, for three-phase motors 400 V, IP21
Assigned motor rating
1), 2), 3)
Assigned motor rating 1), 2), 3)
Fitted with
Moeller® series
Article no.
Frame size
Part no.
I
H
= 150 % I
H
= 150 % I
H
= 150 % I
L
= 110 % I
L
= 110 % I
L
= 110 %
I e
P P I e
P P
A kW HP A kW HP
31
38
46
61
72
4.3
5.6
12
16
23
7.6
9
Mains voltage (50/60Hz) U
LN
U e
= 3 phase / U
2
= 3 phase
: 380 (-15%) - 500 (+10%) V
2.2
3.3
87
105
140
170
Notes
0.75
1.1
3
4
1.5
2.2
5.5
7.5
11
1
1.5
2
3
5
7.5
10
15
3.3
4.3
5.6
7.6
9
12
16
23
31
1.1
1.5
2.2
3
4
5.5
7.5
11
15
1.5
2
3
10
15
20
5
7.5
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓
✓
✓
✓
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓
✓ ✓
✓ ✓
✓ ✓ ✓
✓ ✓
✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
FS1
FS2
IP21/
NEMA1
DG1-342D2FB-C21C
DG1-343D3FB-C21C
DG1-344D3FB-C21C
DG1-345D6FB-C21C
DG1-347D6FB-C21C
DG1-349D0FB-C21C
DG1-34012FB-C21C
DG1-34016FB-C21C
DG1-34023FB-C21C
9702-1002-00P
9702-1004-00P
9702-1006-00P
9702-1008-00P
9702-1001-00P
9702-1011-00P
9702-2002-00P
9702-2004-00P
9702-2001-00P
15
18.5
22
30
37
20
25
30
40
50
38
46
61
72
87
18.5
22
30
37
45
25
30
40
50
60
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓ ✓
✓
✓
✓
✓
FS3 DG1-34031FB-C21C
DG1-34038FB-C21C
DG1-34046FB-C21C
9702-3002-00P
9702-3004-00P
9702-3001-00P
9702-4002-00P
45 60 105 55 75
✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓
✓
✓
✓
✓
✓
FS4 DG1-34061FB-C21C
DG1-34072FN-C21C
DG1-34072FB-C21C
DG1-34087FN-C21C
DG1-34087FB-C21C
9702-4008-00P
9702-4006-00P
9702-4001-00P
9702-4010-00P
9702-5004-00P 55
75
90
75
100
125
140
170
205
75
90
110
100
125
150
✓ ✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓ ✓
✓
✓
✓
✓
✓
FS5 DG1-34105FN-C21C
DG1-34105FB-C21C
DG1-34140FN-C21C
DG1-34140FB-C21C
DG1-34170FN-C21C
DG1-34170FB-C21C
9702-5002-00P
9702-5008-00P
9702-5006-00P
9702-5001-00P
9702-5010-00P
1)
2)
3)
Overload cycle for 60 s every 600 s
For normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm -1 at 50 Hz or 1800 min -1 at 60 Hz
DG1-34…:at 400 V, 50 Hz/at 480 V, 60 Hz
CA08103003Z_MOEM2015-EN.book Seite 217 Donnerstag, 7. April 2016 12:02 12
Moeller® series
DG1, for three-phase motors 400 V/500 V, IP21
PowerXL™ variable frequency drives
DG1, for three-phase motors 400 V/500 V, IP21
DG1, FS1
DG1, FS4
DG1, FS2
DG1, FS5
DG1, FS3
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 217
CA08103003Z_MOEM2015-EN.book Seite 217 Donnerstag, 7. April 2016 12:02 12
Moeller® series
DG1, for three-phase motors 400 V/500 V, IP21
PowerXL™ variable frequency drives
DG1, for three-phase motors 400 V/500 V, IP21
DG1, FS1 DG1, FS2 DG1, FS3
DG1, FS4 DG1, FS5
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 218 Donnerstag, 7. April 2016 12:02 12
PowerXL™ variable frequency drives
Accessories
Accessories
External keypad
Description For use with Part no.
With 7-digital display assembly
Front IP54
With approx. 3 m-long, plug-in connection cable (RJ45, 8-pin)
DE1, DE11, DC1, DA1 DX-KEY-LED
With OLED display
Front IP54
Multilingual
With approx. 3 m-long, plug-in connection cable (RJ45, 8-pin)
DC1, DA1
With LCD display
Front IP54
Multilingual
DG1
DX-KEY-OLED
DXG-KEY-LCD
Mounting frame
With approx. 0.5 m-long, plug-in connection cable
Mounting frame
DXG-KEY-LCD DXG-KEY-RMTKIT
DXG-KEY-HOLDER
Moeller® series
Article no.
169132
169133
730-32047-00P
730-32033-00P
730-32032-00P
Cover for RJ45 interface DXG-KEY-N12PLUG 730-32038-00P
Configuration module
Plug-in module (front)
With selector switch for ramp time and operating mode
With potentiometer for motor protection and fixed frequency
DE1, DE11 DXE-EXT-SET 174621
Expansion modules
Output expansion
2 relay outputs (N/O, 250 V AC/220 V DC, max. 1 A)
1 analog output (0 - +10 V, max. 20 mA)
For connecting to the control signal terminals on the DC1
2 relay outputs (N/O, 250 V AC/220 V DC, max. 1 A)
For connecting to the control signal terminals on the DC1
DC1
DC1
Plug-in module with plug-in terminal block, 5 pole
3 relay outputs (N/O, 250 V AC, max. 6 A/ 30 V DC, max. 5 A)
3 relay outputs
DA1
DG1
DXC-EXT-2RO1AO 169030
DXC-EXT-2RO
DXA-EXT-3RO
DXG-EXT-3RO
169031
169121
744-A2614-00P
I/O expansion
Plug-in module with plug-in terminal blocks, 6 pole
3 digital inputs (+24 V)
1 relay output (N/O, 250 V AC, max. 6 A/ 30 V DC, max. 5 A)
3 digital inputs
3 Digital outputs
1 Thermistor input
DA1
DG1
1 Analog input
2 Analog outputs
DG1
EATON CA08103003Z-EN-INT
DXA-EXT-3DI1RO 169036
DXG-EXT-3DI3DO1T 744-A2612-00P
DXG-EXT-1AI2AO 744-A2613-00P
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 219 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Expansion modules
Input expansion
Description
Thermistor input
PowerXL™ variable frequency drives
For use with
DG1
Part no.
DXG-EXT-THER1
Accessories
Article no.
744-A2615-00P
240-V-AC input (electrically isolated) for 6 digital inputs
DG1 DXG-EXT-6DI 744-A2616-00P
Encoder module
Plug-in module with plug-in terminal block, 5 pole
2-channel
Max. 500 kHz
5 V TTL, A & B, /A & /B, 5 V DC, max. 200 mA
24 V HTL, A & B, /A & /B, 24 V DC, external power supply required, max. 30 V DC
Coupling module
115-V-AC input (electrically isolated)
For 4 digital inputs
For connecting to the control signal terminals on the DC1
230-V-AC input (electrically isolated)
For 4 digital inputs
For connecting to the control signal terminals on the DC1
Simulator
Commissioning and testing simulator
3 digital inputs (+24 V)
1 relay output (max. 30 V DC)
3 microswitches
1 reference value potentiometer (0 - +10 V / = 0 - f max
)
For connecting to the control signal terminals on the DC1
Fieldbus modules
PROFIBUS-DP
SUB-D socket, 9-pole
PROFINET
2 x RJ45, 8 pole
Plug-in module
Modbus TCP
2 x RJ45, 8 pole
EtherNet-IP
2 x RJ45, 8 pole
EtherCAT
2 x RJ45, 8 pole
DeviceNet
DA1
DC1
DC1
DC1
DA1
DA1
DA1
DA1
DA1
DA1
DXA-EXT-ENCOD 169035
DXC-EXT-IO110
DXC-EXT-IO230
169032
169033
DXC-EXT-LOCSIM 169034
DX-NET-PROFIBUS 169124
DX-NET-PROFINET-2 169125
DX-NET-MODBUSTCP-2 169126
DX-NET-ETHERNET-2 169122
DX-NET-ETHERCAT-2
DX-NET-DEVICENET
169127
169123
PROFIBUS-DP
SUB-D socket, 9-pole
DG1 DXG-NET-PROFIBUS 744-A2617-00P
Interface converter from 9-pin SUB-D plug to 3-pin control signal terminal
DXG-NET-PROFIBUS DXG-MNT-PROFIBUS 744-A2618-00P
SmartWire-DT Modules
Plug-in module with slot for SWD4-8SF2-5 external device plug DA1 (IP20, IP55) DX-NET-SWD1 169129
EATON CORPORATION CA08103003Z-EN 219
CA08103003Z_MOEM2015-EN.book Seite 219 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Expansion modules
Input expansion
Description
Thermistor input
PowerXL™ variable frequency drives
For use with
DG1
Part no.
DXG-EXT-THER1
Accessories
Article no.
744-A2615-00P
240-V-AC input (electrically isolated) for 6 digital inputs
DG1 DXG-EXT-6DI 744-A2616-00P
Encoder module
Plug-in module with plug-in terminal block, 5 pole
2-channel
Max. 500 kHz
5 V TTL, A & B, /A & /B, 5 V DC, max. 200 mA
24 V HTL, A & B, /A & /B, 24 V DC, external power supply required, max. 30 V DC
Coupling module
115-V-AC input (electrically isolated)
For 4 digital inputs
For connecting to the control signal terminals on the DC1
230-V-AC input (electrically isolated)
For 4 digital inputs
For connecting to the control signal terminals on the DC1
Simulator
Commissioning and testing simulator
3 digital inputs (+24 V)
1 relay output (max. 30 V DC)
3 microswitches
1 reference value potentiometer (0 - +10 V / = 0 - f max
)
For connecting to the control signal terminals on the DC1
Fieldbus modules
PROFIBUS-DP
SUB-D socket, 9-pole
PROFINET
2 x RJ45, 8 pole
Plug-in module
Modbus TCP
2 x RJ45, 8 pole
EtherNet-IP
2 x RJ45, 8 pole
EtherCAT
2 x RJ45, 8 pole
DeviceNet
DA1
DC1
DC1
DC1
DA1
DA1
DA1
DA1
DA1
DA1
DXA-EXT-ENCOD 169035
DXC-EXT-IO110
DXC-EXT-IO230
169032
169033
DXC-EXT-LOCSIM 169034
DX-NET-PROFIBUS 169124
DX-NET-PROFINET-2 169125
DX-NET-MODBUSTCP-2 169126
DX-NET-ETHERNET-2 169122
DX-NET-ETHERCAT-2
DX-NET-DEVICENET
169127
169123
PROFIBUS-DP
SUB-D socket, 9-pole
DG1 DXG-NET-PROFIBUS 744-A2617-00P
Interface converter from 9-pin SUB-D plug to 3-pin control signal terminal
DXG-NET-PROFIBUS DXG-MNT-PROFIBUS 744-A2618-00P
SmartWire-DT Modules
Plug-in module with slot for SWD4-8SF2-5 external device plug DA1 (IP20, IP55) DX-NET-SWD1 169129
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 220 Donnerstag, 7. April 2016 12:02 12
PowerXL™ variable frequency drives
Accessories
Description
Plug-in module (front) with slot for SWD4-8SF2-5 external device plug
For use with
DE1, DE11, DC1 (IP20)
Part no.
DX-NET-SWD3
Moeller® series
Article no.
169131
PC communication
Parameter storage unit and Bluetooth communication stick
For storage, copying parameters, and/or transferring parameters to a PC with the drivesConnect software via
Bluetooth
With 2 function keys for uploading and downloading parameters
With configuration memory
Interface converter
Interface converter USB/RS485 with connection cable, RJ45,
8 pole
Electrically isolated
1 × SUB-D plug, 9-pole
Terminal strip, 5-terminal
Status-LED
DE1, DE11, DC1, DA1
DE1, DE11, DC1, DA1
DX-COM-STICK
DX-COM-PCKIT
169134
169135
Interface converter USB/RS485 with connection cable, RJ45,
8 pole electrically isolated
RJ45/USB, with CD
DE1, DE11, DC1, DA1
DG1
DX-CBL-PC-1M5
DXG-CBL-PCCABLE
171018
730-32037-00P
License Keys
To activate the function block editor in the DrivesConnect software
USB flash drive DA1 DX-COM-SOFT 169136
Connection cable
Parameter software
Patch cord with RJ45 plugs, 8 pole
-
Patch cord with RJ45 plugs, 8 pole
Patch cord with RJ45 plugs, 8 pole
Length 0.5 m
Length 1 m
Length 3 m
Length 1 m
Length 3 m
DE1, DE11, DC1, DA1
DG1
DG1
DX-CBL-RJ45-0M5
DX-CBL-RJ45-1M0
DX-CBL-RJ45-3M0
DXG-CBL-1M0
DXG-CBL-3M0
169137
169138
169139
730-32034-00P
730-32035-00P
DXG-ACC-SOFTWARE 730-32036-00P
Bus terminating resistor
RJ45
8 pole
Connection to CANopen® (pin 1/2, 124 Ω ) or to Modbus RTU
(pin 7/8, 120 Ω ) easyNet
DX-SPL-RJ45-2SL-1PL
EASY-NT-R 256281
CA08103003Z_MOEM2015-EN.book Seite 221 Donnerstag, 7. April 2016 12:02 12
Moeller® series
PC communication
Splitter
Battery
Description
RJ45, 8-pin, 3 sockets
For CANopen ® and Modbus RTU
RJ45, 8-pin, 2 sockets/1 plug
With cable approx. 10 cm
For CANopen ® and Modbus RTU
RJ45, 8-pin, 2 sockets/1 plug
For CANopen ® and Modbus RTU
RJ45, 8 pole, 1 socket/1 plug
For CANopen ® and Modbus RTU
With 2 resistors, 120 Ω
Battery for real-time clock
Mounting accessories
Mounting frame
For the power section's push-through installation outside the control panel
Frame parts and fixing screws
PowerXL™ variable frequency drives
Accessories
For use with Part no.
Article no.
DX-CBL-RJ45… DX-SPL-RJ45-3SL
DE1, DE11, DC1, DA1 DX-SPL-RJ45
169141
DE1, DE11, DC1, DA1 DX-SPL-RJ45-2SL1PL 169142
179313
DE1, DE11, DC1, DA1 DX-SPL-RJ45-TERM 179314
DXG-ACC-RTBATT 730-32039-00P
DG1 (frame size FS1)
DG1 (frame size FS2)
DG1 (frame size FS3)
DG1 (frame size FS4)
DG1 (frame size FS5)
DXG-ACC-FR1N12FK
DXG-ACC-FR2N12FK
DXG-ACC-FR3N12FK
DXG-ACC-FR4N12FK
DXG-ACC-FR5N12FK
730-32022-00P
730-32023-00P
730-32024-00P
730-32025-00P
730-32026-00P
Mounting set
For increasing the degree of protection from IP21/NEMA 1 to IP54/NEMA 12
Enclosure cover with seals and extra fan DG1-34... (frame size
FS1, 400/480 V)
DG1 (frame size FS2)
DG1 (frame size FS3)
DG1-32... (frame size
FS1, 230 V)
DXG-ACC-4FR1N12KIT
DXG-ACC-FR2N12KIT
DXG-ACC-FR3N12KIT
DXG-ACC-2FR1N12KIT
730-32029-00P
730-32030-00P
730-32031-00P
744-A2815-00P
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 221
CA08103003Z_MOEM2015-EN.book Seite 221 Donnerstag, 7. April 2016 12:02 12
Moeller® series
PC communication
Splitter
Battery
Description
RJ45, 8-pin, 3 sockets
For CANopen ® and Modbus RTU
RJ45, 8-pin, 2 sockets/1 plug
With cable approx. 10 cm
For CANopen ® and Modbus RTU
RJ45, 8-pin, 2 sockets/1 plug
For CANopen ® and Modbus RTU
RJ45, 8 pole, 1 socket/1 plug
For CANopen ® and Modbus RTU
With 2 resistors, 120 Ω
Battery for real-time clock
Mounting accessories
Mounting frame
For the power section's push-through installation outside the control panel
Frame parts and fixing screws
PowerXL™ variable frequency drives
Accessories
For use with Part no.
Article no.
DX-CBL-RJ45… DX-SPL-RJ45-3SL
DE1, DE11, DC1, DA1 DX-SPL-RJ45
169141
DE1, DE11, DC1, DA1 DX-SPL-RJ45-2SL1PL 169142
179313
DE1, DE11, DC1, DA1 DX-SPL-RJ45-TERM 179314
DXG-ACC-RTBATT 730-32039-00P
DG1 (frame size FS1)
DG1 (frame size FS2)
DG1 (frame size FS3)
DG1 (frame size FS4)
DG1 (frame size FS5)
DXG-ACC-FR1N12FK
DXG-ACC-FR2N12FK
DXG-ACC-FR3N12FK
DXG-ACC-FR4N12FK
DXG-ACC-FR5N12FK
730-32022-00P
730-32023-00P
730-32024-00P
730-32025-00P
730-32026-00P
Mounting set
For increasing the degree of protection from IP21/NEMA 1 to IP54/NEMA 12
Enclosure cover with seals and extra fan DG1-34... (frame size
FS1, 400/480 V)
DG1 (frame size FS2)
DG1 (frame size FS3)
DG1-32... (frame size
FS1, 230 V)
DXG-ACC-4FR1N12KIT
DXG-ACC-FR2N12KIT
DXG-ACC-FR3N12KIT
DXG-ACC-2FR1N12KIT
730-32029-00P
730-32030-00P
730-32031-00P
744-A2815-00P
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Hydraulic solutions for productive and economic machines
In a world of increasing pressure for “better, faster, cheaper,” manufacturers face more significant challenges than ever before. Whether making automobiles, clothing, computer chips, plastic bottles, or anything in between, you need every cell in your fine-tuned operation working at its optimal state. When Eaton is on the inside, you can experience the assurance of tireless production.
Produce at peak efficiency with the superior precision and repeatability of Eaton products. Eaton hydraulic components provide the precise control and consistent operation required for virtually every step in your manufacturing operation. With Eaton, we’ll help you redefine the meaning of productivity.
Whether your primary business is mass production or mass customisation, you can count on superior precision and repeatability for increased uptime, year after year.
222 EATON CA08103003Z-EN-INT
Perfect interaction of electrical and
hydraulic technology
Lean Solution ultimately brings together the world of hydraulics and the world of electrical engineering in automation. A fully integrated electro-hydraulic system is a complete solution for your machine. Automation components such as HMI/PLCs communicate perfectly via CANopen with intelligent
Eaton hydraulic valves. The brain of the system is implemented by the HMI/PLC which combines control, visualization and data management tasks with state-of-the-art networking features in a single device. Via a
CANopen fieldbus, the HMI/PLC communicates with drives, I/Os and now with the new AxisPro Proportional Hydraulic valves as well, thus providing full control of machine axis movement. The HMI/PLC can also communicate on SmartWire-DT with pushbutton actuators, indicator lights, and switchgear right up to the sensors, thus providing an efficient solution for connectivity. Eaton’s fully integrated electro-hydraulic system enhances in every respect the machine productivity and performance and simultaneously reduces the wiring, test and commissioning requirement.
EATON CA08103003Z-EN-INT 223
What are your
requirements?
Irrespective of whether you supply original parts for machine components or are an end customer, Eaton is aware of the most critical energy management requirements in the machine-building sector. We are aware of your requirement to reduce the time to market due to the increasingly shorter timespans between the market launch of new models. We also know that the operating costs must be reduced ensuring that you remain a valuable and preferred supplier. Just as we know that you place great emphasis on efficiency, reliability and sustainability.
And this is why we can develop the best solutions together with you, employing products complying to global standards and thus assuring world-wide availability.
Open-Circuit Piston Pumps Eaton AxisPro™ Proportional Valve
Featuring robust bearing designs, Eaton medium-duty PVM pumps deliver longer life and reliable operation for CNC machining tools in metal-cutting applications. The pressure/flow-compensated pumps provide dependable component and system operation without costly breakdowns and maintenance.
Special design techniques reduce both structure- and fluid-born noise and yield extended pump life.
Eaton AxisPro proportional valves provide integrated programmable control capabilities in sophisticated electro-hydraulic axis control applications. These valves contain both programmable onboard electronics and integral spool Linear Voltage Differential Transformer
(LVDT) sensors to provide precise, accurate, responsive axis control capabilities. Their modular design delivers four levels of control ranging from an entry level valve that is quick and easy to configure, right through to a valve that can be customized by uploading application code created by Eaton’s Pro-FX Control software.
Hydraulic Hoses
Eaton offers a wide variety of hose constructions that are ideally suited to a vast array of applications. Our hoses are designed to meet the most demanding applications providing maximum durability and long-lasting performance.
224 EATON CA08103003Z-EN-INT
Walterscheid ® Fittings and
Connectors
Eaton is known worldwide for the breadth, quality, and ease of use of its product line,
Walterscheid ® fittings and connectors. They are used in a broad range of mobile and industrial equipment including agricultural and construction vehicles and machine tools.
Proportional Directional Valves LifeSense™ Hose
Eaton’s specially designed injection P/Q valves provide precise control of injection velocity, smooth transition from velocity to pressure control, and back pressure control that is highly repeatable to produce parts with tight dimensional accuracy and high quality.
The valves are pre-wired with ruggedly
constructed onboard electronics. Factory-set adjustments, including gain, spool dead-band compensation, and offset, ensure high valveto-valve reproducibility.
Eaton is an industry leader in developing new hydraulic hose solutions. Our hydraulic hose products are suitable for nearly any application, pressure level, and fluid type. With
Eaton’s new LifeSense™ condition-based hydraulic hose monitoring system, hydraulic hose failures will no longer be a major concern. LifeSense hose monitors the health of hydraulic hose assemblies, detects events that have been shown to be symptomatic of the hose beginning to fail, and notifies the user prior to failure with enough time to replace the hose before it fails.
Tie Rod Cylinders
Eaton’s Vickers and Hydro-
Line G, N, I, and L Series cylinders include a broad range of NFPA and ISO hydraulic, pneumatic, and electrohydraulic styles focused on industrial markets. This comprehensive line features a proven design coupled with the Eaton SureSeal™ system for improved performance and better serviceability. Virtually unlimited options are available.
EATON CA08103003Z-EN-INT 225
Safe switching and isolation.
• maintenance / manual override switch
• Non-standard switches possible
• maintenance / manual override switch
• Diverse installation and actuation options
INX switchdisconnector
• Disconnectors up to
6300 A
See online catalog
Recording energy consumption and communication
Line and system protection
• Measured value display on location
• BreakerHealth: contact wear indicator
• Installation / extension without removal from the rail
• Integrated auxiliary contact
• Display with error current trip
Visualization and logging software –
BreakerVisu
• Data acquisition for up to 48 devices
• 7" or 3.5" touchscreen display
• Automatic configuration and logging
• Import of 3rd party devices possible
• Gateway function: can forward data to supervisory system
Page 232
• Up to 22xIn start-up current
• No derating with T° variation
• Four NZM switches up to 1600 A
• Very versatile installation and actuation
• Motor, system and generator protection
• IZMX circuit breaker to 6300 A
Page 230 ff.
IZM see
Online catalog
Circuit breakers
NZM + RCCB
• Up to 250 A
• Pulse current sensitive/
AC/DC sensitive
• Rated fault current
I
Δ n
=0.003 A … 3.0 A
See online catalog
226 EATON CA08103003Z-EN-INT
Enclosures
• Reliable protection for all types of distributed switching and automation devices
• Robust and high resistance to chemicals
• Glass-fibre reinforced polycarbonate
• Individual facility for inscription
• Metric cable entry knockouts
• Degree of protection IP66/IK09
• Innovative device adapters and
• Adapters establish an electrical contact without the need to drill holes up to a current of 630 A
Bussmann series fuses
D & DO Fuse links and fuse bases
• Full range of bases and accessories
Cylindrical fuse links and fuse holders
UL Branch circuit and supplementary fuse links
• Full range of fuse holders and fuse blocks
Assuring
Power Quality
• Compact protection from mains power problems
• Diverse communication options
• Power from 8 kVA to 4,400 kVA
• Diverse communication options
• Paralleling capability using HotSync technology
• Battery life management with the Eaton ABM technology
High Speed – Square body fuse links
• Free-of-charge shutdown and management software
• Management of large numbers of
CI enclosure
• Protection on six fronts: dust, moisture, water, corrosive substances, mechanical damage, extreme short-circuits
• Cover lifting mechanism with overpressure compensation
See online catalog
High speed – British standard fuse links
• 240 and 690 VAC
• 6 to 710 Amps
• BS88 part 4 and IEC
60269-4
EATON CA08103003Z-EN-INT 227
228
Circuit protection
Our comprehensive range of circuit protection to reliably protect people, machines and plant, in order to have a safe, productive production line.
Solutions to meet your circuit protection needs
Our expertise and our value-added, modular approach to circuit protection means that we have a reliable solution to meet every application need regardless of machine complexity.
Helping you to speed the machine design and build process while significantly reducing complexity and cost.
Breadth and depth
Our comprehensive range of solutions enables you to overcome increasing complexity and risk to protect for short circuit, overload, overvoltage, arc fault or residual current and cover every aspect of circuit safety:
• Cable and system protection
• Operator protection
• Power conversion protection
• Long distance cable protection
Single supplier
To keep you ahead of complex, changing customer needs and meet global acceptable standards, it’s useful to be able to consolidate your supply network and source components from a single supplier. With Eaton, you can do exactly this.
Cable and system protection
Residual current circuit breaker
Miniature circuit breaker
Long distance cable protection
Modular fuse holder and fuse link
Operator protection
in standard applications
Residual current circuit breaker
Communication and visualization for more energy efficiency
BreakerVisu our logging and visualization system collect the data coming from single devices. This helps to control and optimize energy consumption. SmartWire-DT is only one solution to communicate in the system.
EATON CA08103003Z-EN-INT
Cable and system protection
Communication and visualization
Industrial fuse link
Surge protection device
NZM circuit breaker
SmartWire-DT gateways
Miniature circuit breaker
Long distance cable protection
PKE 65 circuit breaker
SmartWire-DT® module for NZM
Heinemann hydraulic magnetic circuit breaker
Energy measuring module
XMC
Use the right technologies to minimize downtime
BreakerVisu visualization and logging
Power conversion protection
Bolted tags high speed fuse links
Fuse bases for square body high speed fuse links
DIN 43653
High speed fuse links in standard applications in variable frequency drive application
Combined RCD/
MCB devices
All protection technologies available for circuit protection:
• Electronic
• Thermomagnetic
• Hydraulic magnetic
• Fuses
Modular fuse holder and fuse link
Residual current circuit breaker
EATON CA08103003Z-EN-INT
Variable frequency drive
229
Provide, log, and visualize main switch energy data
Eaton NZM circuit breakers and P switch-disconnectors are used as main switches for a wide variety of machines. On top of this, NZM circuit breakers provide reliable short-circuit and overload protection. But they also offer much more: Their field bus interfaces make it possible to send advance warnings and transmit diagnostic data, as well as energy consumption values. Critical current warnings make it possible to take countermeasures and prevent overload tripping. Diagnostic data provides information regarding the cause behind faults and malfunctions and makes it possible to obtain trend analyses designed to identify load peaks. Moreover, NZM circuit breakers make it easy to tackle today's focus on energy consumption by measuring and communicating operational data. This data, in turn, can be easily integrated into the
BreakerVisu visualization and logging system in a user-friendly manner.
230 www.eaton.eu/nzm
EATON CA08103003Z-EN-INT
Main switch application
The voltage is switched off on all current conducting circuits when the switch is switched off using the undervoltage release with two integrated early-make auxiliary contacts. This makes it possible to use Eaton's new products in order to easily and cost-effectively implement a main switch application with an emergency stop function for currents of up to 1,600 A that complies with standard
IEC 60204-1, VDE 0113, Part 1.
Rear operator
If a power disconnecting device with door coupling rotary handle is to be used in a confined space: up to 300 A rated operational current can be quickly mounted using the compact mechanical features and comfortably operated using the solid rotary handle. All switch variants from the NZM1 and NZM2 range – regardless of if they are circuit breakers or switchdisconnectors – can be combined with a rear operator.
Flange operator
Up to 1600 A, the flange operator enables the switch to be operated from the right or left hand side as desired.
Optional fitting of our mounting bracket results in optimum use of space in the control panel. The mounting plate can thus be used for other machine control elements.
Load warnings
Flexible measuring points Smaller NZM-XMC designs
Preventive safety
Remote switching
By providing valuable real-time diagnostic information regarding connected devices, BreakerVisu works together with the reliable short-circuit and overload protection provided by NZM circuit breakers in order to help prevent expensive production downtimes. This setup not only includes standard alarm messages, but also ensures that the advance overload warning function in the PKE motor-protective circuit breaker will send a warning before tripping and make it possible to determine how close the circuit breaker is to tripping. If a trip does occur, the BreakerHealth function will indicate the condition of the NZM circuit breakers' main contacts, making it possible to schedule preventive maintenance appropriately.
Measuring electrical parameters is the foundation of energy management in machine main switches. This is where NZM-XMC measuring and communication modules come in as an ideal alternative to integrated measuring systems. In fact, the new
NZM-XMC-TC-MB measuring transducer is particularly well-suited to being retrofitted in existing systems thanks to the use of external current transformers. Moreover, its compact design and top hat DIN rail mounting system mean that it can be installed pretty much anywhere.
With its NZM-XMC-MB-250 unit, Eaton offers a compact frame size for currents of up to 250 A that is specifically customized for size 2 NZM devices. In fact, the unit's clearance between cables and busbars is perfectly configured for NZM2 models.
This eliminates the need for cable and bar bends and cuts down on both costs and installation times.
EATON CA08103003Z-EN-INT 231
BreakerVisu – Functionality overview
Operational data acquisition
With its BreakerVisu system, Eaton offers a cost-effective solution for state-of-the-art power management needs. The system features a multi-breaker display that shows all the operational data for connected circuit breakers and measuring devices in a centralized and clearly laid out manner. This ability to have all important operational data be displayed on a single 3.5" or 7" touch panel human-machine interface has multiple advantages, not the least of which is the fact that the availability of this data is automatically increased. Moreover, it significantly lowers costs in comparison to conventional switchgear with individual indicators and displays for each individual circuit breaker. And to top it all off, BreakerVisu is a turnkey solution that is immediately ready for operation out of the box.
Function overview
• Collects data from multiple devices
(up to 32 Modbus RTU & 16 SmartWire-DT)
• Visualizes data locally or via remote Ethernet access
• Logs data (data, energy, and event logging)
• Can be connected to a control system via Modbus TCP, as well as to a CoDeSys OPC server
• Can accommodate non-Moeller devices through Modbus
RTU
• New version with turnkey design (hardware and software)
• Plug & play
• Visit www.eaton.eu/breakervisu
The menu guidance is simple and clearly structured. The menu bar used to select the individual menu items is located in the upper area. A simple “touch” is all it takes to get to an overview screen for one of the field bus networks, e.g. Modbus.
Network overview
This screen lists all connected devices. A compact overview shows information on the circuit breaker types and states, as well as on the current currents and power meters. In addition to this, the screen also shows alarm messages and a custom name.
This view provides users with a quick and compact overview of their switchgear or machine, as well as the corresponding measuring points. More extensive operational data is displayed if a switch is selected. Moreover, the logging function can be enabled and diagnostic data can be displayed and exported.
Logging function
With BreakerVisu, logging operational data is as simple as never before. You can select which specific data you want to log, with three ready-to-use settings making things easier:
1. Event logging:
Automatically collects status and error messages from the entire system. Always active.
2. Energy logging:
Collects power consumption data from all connected devices with a single click.
3. Data logging:
Collects all measured data for a connected device. Can be enabled individually for each device.
BreakerVisu speaks many languages
BreakerVisu's default language is English. It also comes with
German and French out of the box. You can select a language the first time you start BreakerVisu or later on from the home screen. But BreakerVisu is not limited to just three languages: additional language packages, such as English – Russian – Polish, can be downloaded and installed. English is included in all language packages as the default language.
As of this writing, BreakerVisu has a total of 18 different languages available. Additional language packages can be created if necessary.
Language packages are available at www.eaton.eu/breakervisu.
232 EATON CA08103003Z-EN-INT
Moeller® series
33
31
34
3
4
2
5
1
6
NZM circuit breakers, switch-disconnectors
System overview
9 7
8
10
11 12
13
14
30
32
15
17
18
29
16
28
27
26
23
20
24
25
21
19
35
22
1 Switch-disconnector; circuit breaker; circuit breaker for North
America; Molded case switches for North
America
2 IP2X protection against contact with a finger
3 Terminal cover, knockout
4 Terminal cover
5 IP2X protection against contact with a finger
6 Tunnel terminals
7 Box terminals
8 Control circuit terminal
9 Connection width extension
10 Plug-in and withdrawable unit
11 Adapter plate
12 Busbar adapter
13 Connection on rear
14 Spacer
15 Standard auxiliary contacts, trip-indicating auxiliary switches
16 Measuring and communication module
17 Residual-current protection device
18 Rear operator
19 Main switch rotary handle for side panel mounting
20, Door coupling rotary
22 handle
21 Extension shaft
23 Rotary handle
24 Insulating surround
25 External warning plate/ marking plate
26 Remote operator
EATON CA08103003Z-EN-INT
27 Toggle lever interlock device
28 Side operator handle
29 Mechanical interlock
30 Display
31 BreakerVisu Display
32 NZM communication module for
SmartWire-DT
33 Voltage release/Earlymake auxiliary contact
34 Delay unit for undervoltage releases
35 Insulated enclosure
233
CA08103003Z_MOEM2015-EN.book Seite 234 Donnerstag, 7. April 2016 12:02 12
NZM circuit-breakers, switch-disconnectors
Circuit-breaker, 3 pole Moeller® series
Circuit-breaker, 3 pole
Rated current = rated uninterrupted current
Setting range
Overload trip Short-circuit releases
Nondelayed
I i
= I n
x … I
Delayed sd
= I r
x … I n
= I u
A
I r
17
A
System and cable protection: Thermomagnetic release
Fixed, Box terminal
100
125
160
Fixed, Screw connection
160
200
250
300
320
400
500
40
50
63
80
20
25
32
15 - 20
20 - 25
25 - 32
32 - 40
40 - 50
50 - 63
63 - 80
80 - 100
100 - 125
125 - 160
125 - 160
160 - 200
200 - 250
240 - 300
250 - 320
320 - 400
400 - 500
6 - 10
6 - 10
6 - 10
5 - 8.3
6 - 10
6 - 10
6 - 10
350 A fixed -
350 A fixed -
350 A fixed -
8 - 10
6 - 10
6 - 10
6 - 10 -
-
-
-
6 - 10
6 - 10
1280 A fixed -
-
-
Systems, cable, selectivity and generator protection: Electronic release
Fixed, Screw connection
-
-
-
-
-
-
-
100
160
250
50 - 100
80 - 160
125 - 250
1200 A fixed 2 - 10
1920 A fixed 2 - 10
3000 A fixed 2 - 10
Switching capacity
400/415 V 50/60 Hz
Part no.
Switching capacity
400/415 V 50/60 Hz
Article no.
Part no.
Article no.
Basic switching capacity
25 kA
NZMB1-A20
NZMB1-A25
280987
280988
NZMB1-A32 280989
NZMB1-A40
NZMB1-A50
NZMB1-A63
NZMB1-A80
NZMB1-A100
NZMB1-A125
NZMB1-A160
259075
259076
259077
259078
259079
259080
281230
NZMB2-A160
NZMB2-A200
NZMB2-A250
-
-
-
NZMB2-A300
259088
259089
259090
107518
Normal switching capacity
50 kA
NZMN2-VE100
NZMN2-VE160
NZMN2-VE250
259122
259123
259124
Normal switching capacity
50 kA
NZMN1-A20
NZMN1-A25
281231
281232
NZMN1-A32 281233
NZMN1-A40
NZMN1-A50
NZMN1-A63
NZMN1-A80
NZMN1-A100
NZMN1-A125
NZMN1-A160
259081
259082
259083
259084
259085
259086
281234
NZMN2-A160
NZMN2-A200
NZMN2-A250
NZMN2-A300
NZMN3-A320
NZMN3-A400
NZMN3-A500
259092
259093
259094
107580
109669
109670
109671
High switching capacity
150 kA
NZMH2-VE100
NZMH2-VE160
NZMH2-VE250
259125
259126
259127
250
400
630
125 - 250
200 - 400
315 - 630
2 - 11
2 - 11
2 - 8
2 - 10
2 - 10
1.5 - 7
NZMN3-VE250
NZMN3-VE400
NZMN3-VE630
259131
259132
259133
NZMH3-VE250
NZMH3-VE400
NZMH3-VE630
259134
259135
259136
CA08103003Z_MOEM2015-EN.book Seite 235 Donnerstag, 7. April 2016 12:02 12
Moeller® series
NZM circuit-breakers, switch-disconnectors
Circuit-breaker, Switch-disconnectors, 3 pole
Circuit-breaker, Switch-disconnectors, 3 pole
Rated current
= rated uninterrupted current
Setting range
Overload trip
Short-circuit releases
Non-delayed
I n
= I u
A
I r
A
I i
= I n
x …
Motor protection: Thermomagnetic release
Tripping class 10 A
Fixed, Box terminal
With phase-failure sensitivity
40
50
63
80
Fixed, Screw connection
100
125
160
200
32 - 40
40 - 50
50 - 63
63 - 80
80 - 100
100 - 125 8 - 14
125 - 160 8 - 14
160 - 200 8 - 14
8 - 14
8 - 14
8 - 14
8 - 14
8 - 12.5
Motor rating
AC-3 50/60 Hz
55
75
110
380 V 400 V
P kW
18.5
22
30
37
45
36
41
55
68
81
99
134
196
Rated operational current AC-3
50/60 Hz
400 V
I e
A
Switching capacity
400/415 V 50/60 Hz
Part no.
Switching capacity
400/415 V 50/60 Hz
Article no.
Part no.
Article no.
Basic switching capacity
25 kA
NZMB1-M40
NZMB1-M50
265710
265711
NZMB1-M63
NZMB1-M80
265712
265713
NZMB1-M100 265714
NZMB2-M125 265715
NZMB2-M160 265716
NZMB2-M200 265717
Normal switching capacity
50 kA
NZMN1-M40
NZMN1-M50
265718
265719
NZMN1-M63
NZMN1-M80
265720
265721
NZMN1-M100 265722
NZMN2-M125 265723
NZMN2-M160 265724
NZMN2-M200 265725
Motor protection: Electronic release
Fixed, Screw connection
With phase-failure sensitivity, Adjustable release class
220 110 - 220 2 - 14
350
450
175 - 350 2 - 14
225 - 450 2 - 14
110
200
250
196
349
437
Normal switching capacity
50 kA
NZMN3-ME220 265781
NZMN3-ME350 265782
NZMN3-ME450 284468
High switching capacity
150 kA
NZMH3-ME220 265789
NZMH3-ME350 265790
NZMH3-ME450 284469
Rated current = rated uninterrupted current
I n
= I u
A
Switch-disconnectors
3 contactor states I, +, 0
Can be remotely operated with voltage release XU/XA, remote operator XR,
Can be equipped with M22-K… trip-indicating auxiliary switch
Fixed, Box terminal
63
100
125
160
Fixed, Screw connection
160
200
250
400
630
250
250
250
630
630
125
125
125
160
Short-circuit protection max. fuse gL-characteristic Part no.
A gL
Article no.
N1-63
N1-100
N1-125
N1-160
N2-160
N2-200
N2-250
N3-400
N3-630
259143
259144
259145
281236
266008
266009
266010
266019
266020
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 235
CA08103003Z_MOEM2015-EN.book Seite 235 Donnerstag, 7. April 2016 12:02 12
Moeller® series
NZM circuit-breakers, switch-disconnectors
Circuit-breaker, Switch-disconnectors, 3 pole
Circuit-breaker, Switch-disconnectors, 3 pole
Rated current
= rated uninterrupted current
Setting range
Overload trip
Short-circuit releases
Non-delayed
I n
= I u
A
I r
A
I i
= I n
x …
Motor protection: Thermomagnetic release
Tripping class 10 A
Fixed, Box terminal
With phase-failure sensitivity
40
50
63
80
Fixed, Screw connection
100
125
160
200
32 - 40
40 - 50
50 - 63
63 - 80
80 - 100
100 - 125 8 - 14
125 - 160 8 - 14
160 - 200 8 - 14
8 - 14
8 - 14
8 - 14
8 - 14
8 - 12.5
Motor rating
AC-3 50/60 Hz
55
75
110
380 V 400 V
P kW
18.5
22
30
37
45
36
41
55
68
81
99
134
196
Rated operational current AC-3
50/60 Hz
400 V
I e
A
Switching capacity
400/415 V 50/60 Hz
Part no.
Switching capacity
400/415 V 50/60 Hz
Article no.
Part no.
Article no.
Basic switching capacity
25 kA
NZMB1-M40
NZMB1-M50
265710
265711
NZMB1-M63
NZMB1-M80
265712
265713
NZMB1-M100 265714
NZMB2-M125 265715
NZMB2-M160 265716
NZMB2-M200 265717
Normal switching capacity
50 kA
NZMN1-M40
NZMN1-M50
265718
265719
NZMN1-M63
NZMN1-M80
265720
265721
NZMN1-M100 265722
NZMN2-M125 265723
NZMN2-M160 265724
NZMN2-M200 265725
Motor protection: Electronic release
Fixed, Screw connection
With phase-failure sensitivity, Adjustable release class
220 110 - 220 2 - 14
350
450
175 - 350 2 - 14
225 - 450 2 - 14
110
200
250
196
349
437
Normal switching capacity
50 kA
NZMN3-ME220 265781
NZMN3-ME350 265782
NZMN3-ME450 284468
High switching capacity
150 kA
NZMH3-ME220 265789
NZMH3-ME350 265790
NZMH3-ME450 284469
Rated current = rated uninterrupted current
I n
= I u
A
Switch-disconnectors
3 contactor states I, +, 0
Can be remotely operated with voltage release XU/XA, remote operator XR,
Can be equipped with M22-K… trip-indicating auxiliary switch
Fixed, Box terminal
63
100
125
160
Fixed, Screw connection
160
200
250
400
630
250
250
250
630
630
125
125
125
160
Short-circuit protection max. fuse gL-characteristic Part no.
A gL
Article no.
N1-63
N1-100
N1-125
N1-160
N2-160
N2-200
N2-250
N3-400
N3-630
259143
259144
259145
281236
266008
266009
266010
266019
266020
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 236 Donnerstag, 7. April 2016 12:02 12
NZM circuit-breakers, switch-disconnectors
UL/CSA, IEC circuit-breaker, Molded case switches for North America, 3 pole
UL/CSA, IEC circuit-breaker, Molded case switches for North America, 3 pole
Rated current = rated uninterrupted current
Setting range
Overload trip
I n
= I u
A
I r
A
System and cable protection: Thermomagnetic release
Adjustable overload releases Ir
Fixed, Box terminal
Fixed, Screw connection
100
125
20
25
32
40
50
63
80
50
63
80
100
125
20
25
32
40
15 - 20
20 - 25
25 - 32
32 - 40
40 - 50
50 - 63
63 - 80
80 - 100
100 - 125
15 - 20
20 - 25
25 - 32
32 - 40
40 - 50
50 - 63
63 - 80
80 - 100
100 - 125
160
200
250
125 - 160
160 - 200
200 - 250
System and cable protection: Electronic release
Adjustable overload releases Ir
R.m.s. value measurement and “thermal memory”
Fixed, Screw connection
250
400
600
125 - 250
200 - 400
300 - 600
Moeller® series
Short-circuit releases
Non-delayed
I i
= I n
x …
Switching capacity
480 V 60 Hz
Part no.
Article no.
Switching capacity
480 V 60 Hz
Part no.
Article no.
350 A fixed
350 A fixed
350 A fixed
8 - 10
6 - 10
6 - 10
6 - 10
6 - 10
6 - 10
350 A fixed
350 A fixed
350 A fixed
8 - 10
6 - 10
6 - 10
6 - 10
6 - 10
6 - 10
6 - 10
6 - 10
6 - 10
2 - 11
2 - 11
2 - 8
Normal switching capacity
35 kA
NZMN1-A20-NA
NZMN1-A25-NA
281570
281571
NZMN1-A32-NA
NZMN1-A40-NA
281572
274237
NZMN1-A50-NA
NZMN1-A63-NA
NZMN1-A80-NA
NZMN1-A100-NA
NZMN1-A125-NA
274239
274240
274241
274242
281573
NZMN2-A20-NA
NZMN2-A25-NA
NZMN2-A32-NA
NZMN2-A40-NA
NZMN2-A50-NA
NZMN2-A63-NA
NZMN2-A80-NA
NZMN2-A100-NA
NZMN2-A125-NA
269217
269218
269219
269220
269221
269222
269223
269224
269225
NZMN2-A160-NA
NZMN2-A200-NA
NZMN2-A250-NA
269226
269227
271106
Normal switching capacity
42 kA
NZMN3-AE250-NA 269299
NZMN3-AE400-NA 269300
NZMN3-AE600-NA 269301
-
-
-
-
-
-
-
-
-
High switching capacity
150 kA
NZMH2-A20-NA
NZMH2-A25-NA
269228
269229
NZMH2-A32-NA
NZMH2-A40-NA
NZMH2-A50-NA
NZMH2-A63-NA
269230
269231
269232
269233
NZMH2-A80-NA
NZMH2-A100-NA
269234
269235
NZMH2-A125-NA 269236
High switching capacity
100 kA
NZMH2-A160-NA
NZMH2-A200-NA
NZMH2-A250-NA
269237
269238
271107
High switching capacity
100 kA
NZMH3-AE250-NA 269302
NZMH3-AE400-NA 269303
NZMH3-AE600-NA 269304
Molded case switches for North America
Fixed short-circuit release (self-protection)
3 contactor states I, +, 0
Can be remotely operated with voltage release XU/XA, remote operator XR,
Can be equipped with M22-K… trip-indicating auxiliary switch
Fixed, Box terminal
Fixed, Screw connection
63
100
125
160
200
250
400
600
-
-
-
-
-
-
-
-
1250 A fixed
1250 A fixed
1250 A fixed
2500 A fixed
2500 A fixed
2500 A fixed
6600 A fixed
6600 A fixed
EATON CA08103003Z-EN-INT
High switching capacity
35 kA
NS1-63-NA
NS1-100-NA
102681
102682
NS1-125-NA 102683
High switching capacity
100 kA
NS2-160-NA
NS2-200-NA
102684
102685
NS2-250-NA
NS3-400-NA
NS3-600-NA
102686
102687
102688
-
-
-
-
-
-
-
-
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 237 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Connection types
For use with
NZM circuit-breakers, switch-disconnectors
Connection types
Terminal capacities
Connection Terminal capacities mm 2
Part no. suffix Article no.
When ordering with basic device
Part no.
Article no.
When ordered separately
Connection types NZM1
Control circuit terminal
Multi tunnel terminal
NZM1, PN1, N(S)1
NZM1, N(S)1 ≦ 160 A
Terminal cover, knockout, not UL/CSA approved
For box terminal
NZM1, N1
Shroud
NZM1, N(S)1
IP2X protection against contact with a finger
For box terminal
NZM1, N1
For cover NZM1-XKSA or NZM1 or NZM1...(C)NA und N(S)1...NA
NZM1, N(S)1 -
Phase isolators
NZM1, N(S)1 -
-
-
-
Box terminal 1 x 0.75 - 2.5
2 x 0.75 - 1.5
-
Cu cable 6 x 2.5 - 16 -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NZM-XSTK 266739
NZM1-XKAM 144112
NZM1-XKSFA 100780
NZM1-XKSA 260021
NZM1-XIPK 266744
NZM1-XIPA 266748
NZM1-XKP 119862
Connection types NZM2
Box terminal
NZM2, N(S)2 ≦ 160 A
NZM2, N(S)2 > 160 A
Multi tunnel terminal
NZM2, N(S)2 ≦ 250 A
Control circuit terminal
NZM2, PN2, N(S)2
NZM2, PN2, N(S)2
Cable lug-cover
NZM2, N(S)2
Cu cable
Cu cable
1 x 10 - 185
2 x 4 - 70
6 x 2.5 - 35 -
+NZM2-160-XKCO 262218
+NZM2-160-XKCU 262223
+NZM2-250-XKCO 262242
+NZM2-250-XKCU 262243
-
-
NZM2-160-XKC 262240
-
-
NZM2-250-XKC 262244
-
NZM2-XKAM 144113
Screw connection
Box terminal
1 x 0.75 - 2.5
2 x 0.75 - 1.5
1 x 0.75 - 2.5
2 x 0.75 - 1.5
-
-
Copper cable lugs
Aluminium cable lug
1 x 10 - 185
2 x 4 - 70
1 x 10 - 50
2 x 10 - 50
-
-
-
-
NZM2-XSTS 260156
NZM-XSTK 266739
NZM2-XKSAE 119868
EATON CORPORATION CA08103003Z-EN 237
CA08103003Z_MOEM2015-EN.book Seite 237 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Connection types
For use with
NZM circuit-breakers, switch-disconnectors
Connection types
Terminal capacities
Connection Terminal capacities mm 2
Part no. suffix Article no.
When ordering with basic device
Part no.
Article no.
When ordered separately
Connection types NZM1
Control circuit terminal
Multi tunnel terminal
NZM1, PN1, N(S)1
NZM1, N(S)1 ≦ 160 A
Terminal cover, knockout, not UL/CSA approved
For box terminal
NZM1, N1
Shroud
NZM1, N(S)1
IP2X protection against contact with a finger
For box terminal
NZM1, N1
For cover NZM1-XKSA or NZM1 or NZM1...(C)NA und N(S)1...NA
NZM1, N(S)1 -
Phase isolators
NZM1, N(S)1 -
-
-
-
Box terminal 1 x 0.75 - 2.5
2 x 0.75 - 1.5
-
Cu cable 6 x 2.5 - 16 -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NZM-XSTK 266739
NZM1-XKAM 144112
NZM1-XKSFA 100780
NZM1-XKSA 260021
NZM1-XIPK 266744
NZM1-XIPA 266748
NZM1-XKP 119862
Connection types NZM2
Box terminal
NZM2, N(S)2 ≦ 160 A
NZM2, N(S)2 > 160 A
Multi tunnel terminal
NZM2, N(S)2 ≦ 250 A
Control circuit terminal
NZM2, PN2, N(S)2
NZM2, PN2, N(S)2
Cable lug-cover
NZM2, N(S)2
Cu cable
Cu cable
1 x 10 - 185
2 x 4 - 70
6 x 2.5 - 35 -
+NZM2-160-XKCO 262218
+NZM2-160-XKCU 262223
+NZM2-250-XKCO 262242
+NZM2-250-XKCU 262243
-
-
NZM2-160-XKC 262240
-
-
NZM2-250-XKC 262244
-
NZM2-XKAM 144113
Screw connection
Box terminal
1 x 0.75 - 2.5
2 x 0.75 - 1.5
1 x 0.75 - 2.5
2 x 0.75 - 1.5
-
-
Copper cable lugs
Aluminium cable lug
1 x 10 - 185
2 x 4 - 70
1 x 10 - 50
2 x 10 - 50
-
-
-
-
NZM2-XSTS 260156
NZM-XSTK 266739
NZM2-XKSAE 119868
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 238 Donnerstag, 7. April 2016 12:02 12
NZM circuit-breakers, switch-disconnectors
Connection types
For use with Terminal capacities
Connection Terminal capacities mm 2
Phase isolators
NZM2, N(S)2 -
Moeller® series
-
Part no. suffix Article no.
When ordering with basic device
Part no.
NZM2-XKP
Article no.
When ordered separately
119864
IP2X protection against contact with a finger
For box terminal
NZM2, PN2, N2 -
For cover NZM2-XKSA or NZM2 or NZM2...(C)NA und N(S)2...NA
NZM2, PN2, N(S)2 -
CU-Cable lug
Not UL/CSA approved.
When using without cover NZM2 (-4)-XKSA, the cable lug must be insulated.
NZM2, N2 -
-
-
-
Connection types NZM3
Box terminal
NZM3, N(S)3 Cu cable
Control circuit terminal
NZM3, PN3, N(S)3 Screw connection
Box terminal
-
-
95
120
150
185 -
-
-
-
-
-
-
-
-
-
-
-
1 x 35 … 240
2 x 16 … 120
+NZM3-XKCO
+NZM3-XKCU
262246
262245
1 x 0.75 … 2.5
2 x 0.75 … 1.5
-
1 x 0.75 - 2.5
2 x 0.75 - 1.5
-
-
Cable lug-cover
Phase isolator
NZM3, N(S)3
NZM3, N(S)3 -
Copper cable lugs
Aluminium cable lug
1 x 16 - 240
2 x 16 - 240
1 x 10 - 120
2 x 10 - 120
-
-
-
-
NZM2-XIPK 266773
NZM2-XIPA 266777
KS95-NZM7 059775
KS120-NZM7 059776
KS150-NZM7 059777
NZM2-XKS185 260032
-
NZM3-XKC
-
260042
NZM3/4-XSTS 266797
NZM-XSTK 266739
NZM3-XKSAE 119869
NZM3-XKP 100512
IP2X protection against contact with a finger
For box terminal
NZM3, N3 -
For cover NZM3-XKSA or NZM3 or NZM3...(C)NA und N(S)3...NA
NZM3, N(S)3 -
CU-Cable lug
Not UL/CSA approved.
When using without cover NZM3(-4)-XKSA, the cable lug must be insulated.
NZM3, N3 -
-
-
-
-
185
240
300
-
-
-
-
-
-
-
-
-
-
NZM3-XIPK 266804
NZM3-XIPA 266808
NZM3-XKS185 260040
NZM3-XKS240 260041
NZM3-XKS300 153186
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 239 Donnerstag, 7. April 2016 12:02 12
NZM circuit-breakers, switch-disconnectors
Moeller® series
Auxiliary contacts
For use with Contacts
= safety function, by positive opening to IEC/EN 60947-5-1
N/O =
Normally open
N/C =
Normally closed
Part no.
Auxiliary contact with screw connection/spring-cage terminal
Standard auxiliary contact (HIN)
Switching with the main contacts Used for indicating and interlocking tasks.
Single contact NZM1, 2, 3
N(S)1, 2, 3
-
1 N/O -
1 NC
M22-K10
M22-K01
Early-make auxiliary contact
For interlocking and load shedding circuits, as well as for early make of the undervoltage release in main switch/Emergencystop applications with terminal block on the left-hand switch side
NZM1
N(S)1
2 N/O NZM1-XHIV
Auxiliary contacts
Article no.
216376
216378
259426
NZM2, 3
N(S)2, 3
2 N/O NZM2/3-XHIV 259430
Trip-indicating auxiliary switch (HIA)
General trip indication '+', when tripped by shunt release, overload release, short-circuit release or by the residual-current release due to residual-current.
Single contact NZM1, 2, 3
N(S)1, 2, 3
-
1 N/O -
1 NC
M22-K10
M22-K01
Part no.
For use with Rated control voltage
U s
V
Undervoltage releases
Without auxiliary contacts
Non-delayed disconnection of NZM circuit-breaker or N switch-disconnector when the control voltage sinks below
35 – 70% U
S
.
For use with emergency switching off devices in conjunction with Emergency switching off button.
With terminal block on the left-hand switch side
NZM1
N(S)1
208 - 240 V 50/60 Hz
380 - 440 V 50/60 Hz
24 V DC
With bolt connection NZM2, 3
N(S)2, 3
208 - 240 V 50/60 Hz
380 - 440 V 50/60 Hz
24 V DC
216376
216378
Article no.
NZM1-XU208-240AC
NZM1-XU380-440AC
NZM1-XU24DC
NZM2/3-XU208-240AC
NZM2/3-XU380-440AC
NZM2/3-XU24DC
259442
259444
259452
259499
259501
259509
Shunt releases
Without auxiliary contacts
Switches are tripped by a voltage pulse or by the application of uninterrupted voltage.
With terminal block on the left-hand switch side
NZM1
N(S)1
24 V AC/DC
208 - 250 V AC/DC
With bolt connection NZM2, 3
N(S)2, 3
24 V AC/DC
208 - 250 V AC/DC
NZM1-XA24AC/DC
NZM1-XA208-250AC/DC
259708
259726
NZM2/3-XA24AC/DC
NZM2/3-XA208-250AC/DC
259754
259763
EATON CORPORATION CA08103003Z-EN 239
CA08103003Z_MOEM2015-EN.book Seite 239 Donnerstag, 7. April 2016 12:02 12
NZM circuit-breakers, switch-disconnectors
Moeller® series
Auxiliary contacts
For use with Contacts
= safety function, by positive opening to IEC/EN 60947-5-1
N/O =
Normally open
N/C =
Normally closed
Part no.
Auxiliary contact with screw connection/spring-cage terminal
Standard auxiliary contact (HIN)
Switching with the main contacts Used for indicating and interlocking tasks.
Single contact NZM1, 2, 3
N(S)1, 2, 3
-
1 N/O -
1 NC
M22-K10
M22-K01
Early-make auxiliary contact
For interlocking and load shedding circuits, as well as for early make of the undervoltage release in main switch/Emergencystop applications with terminal block on the left-hand switch side
NZM1
N(S)1
2 N/O NZM1-XHIV
Auxiliary contacts
Article no.
216376
216378
259426
NZM2, 3
N(S)2, 3
2 N/O NZM2/3-XHIV 259430
Trip-indicating auxiliary switch (HIA)
General trip indication '+', when tripped by shunt release, overload release, short-circuit release or by the residual-current release due to residual-current.
Single contact NZM1, 2, 3
N(S)1, 2, 3
-
1 N/O -
1 NC
M22-K10
M22-K01
Part no.
For use with Rated control voltage
U s
V
Undervoltage releases
Without auxiliary contacts
Non-delayed disconnection of NZM circuit-breaker or N switch-disconnector when the control voltage sinks below
35 – 70% U
S
.
For use with emergency switching off devices in conjunction with Emergency switching off button.
With terminal block on the left-hand switch side
NZM1
N(S)1
208 - 240 V 50/60 Hz
380 - 440 V 50/60 Hz
24 V DC
With bolt connection NZM2, 3
N(S)2, 3
208 - 240 V 50/60 Hz
380 - 440 V 50/60 Hz
24 V DC
216376
216378
Article no.
NZM1-XU208-240AC
NZM1-XU380-440AC
NZM1-XU24DC
NZM2/3-XU208-240AC
NZM2/3-XU380-440AC
NZM2/3-XU24DC
259442
259444
259452
259499
259501
259509
Shunt releases
Without auxiliary contacts
Switches are tripped by a voltage pulse or by the application of uninterrupted voltage.
With terminal block on the left-hand switch side
NZM1
N(S)1
24 V AC/DC
208 - 250 V AC/DC
With bolt connection NZM2, 3
N(S)2, 3
24 V AC/DC
208 - 250 V AC/DC
NZM1-XA24AC/DC
NZM1-XA208-250AC/DC
259708
259726
NZM2/3-XA24AC/DC
NZM2/3-XA208-250AC/DC
259754
259763
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 240 Donnerstag, 7. April 2016 12:02 12
NZM circuit-breakers, switch-disconnectors
Door coupling rotary handles
Door coupling rotary handles
For use with
Door coupling rotary handles
Complete including rotary drive and coupling parts
Extension shaft additionally required.
Protection class IP66 UL/CSA Type 4X, Type 12
Standard, black/grey
Lockable on the 0 position on the handle using up to 3 padlocks
With door interlock
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3
Lockable on the handle on the switch using up to 3 padlocks
Modifiable on handle in I position as well
With door interlock
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3
Part no.
NZM1-XTVD
NZM2-XTVD
NZM3-XTVD
NZM1-XTVDV
NZM2-XTVDV
NZM3-XTVDV
Article no.
Notes
Moeller® series
260166
260168
260170
Door interlock
• Not defeated in the locked OFF and ON positions
• Can be modified in the unlocked ON position
• Can be modified such that it can be defeated from the outside using a screwdriver
• Door can be opened in OFF
• External warning plate/designation label can be clipped on.
260172
260174
260176
Red-yellow for emergency switching off
Lockable on the handle on the switch using up to 3 padlocks
With door interlock
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3
NZM1-XTVDVR
NZM2-XTVDVR
NZM3-XTVDVR
260178
260180
260182
Door interlock
• Not defeated in the locked OFF position.
• Can be modified in the unlocked ON position
• Can be modified such that it can be defeated from the outside using a screwdriver
• Door can be opened in OFF
• External warning plate/designation label can be clipped on.
Door coupling rotary handle for North America
Complete including rotary drive and coupling parts
Extension shaft additionally required.
Protection class IP66 UL/CSA Type 4X, Type 12
Standard, black/grey
Lockable on the 0 position on the handle using up to 3 padlocks
With door interlock
NZM1, N1
NZM2, N2
NZM3, N3
Red-yellow for emergency switching off
Lockable on the handle on the switch using up to 3 padlocks
With door interlock
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3
NZM1-XTVD-NA
NZM2-XTVD-NA
NZM3-XTVD-NA
271445
271446
271447
Door interlock
• Not defeated in the locked OFF position.
• Door opens only with active rotation beyond the
0 position
• Cannot be combined with mechanical interlock
• External warning plate/designation label can be clipped on.
NZM1-XTVDVR-NA
NZM2-XTVDVR-NA
271449
271450
NZM3-XTVDVR-NA 271451
Door interlock
• Not defeated in the locked OFF position.
• Door opens only with active rotation beyond the
0 position
• Cannot be combined with mechanical interlock
• External warning plate/designation label can be clipped on.
Extension shaft
400 mm max. mounting depth
600 mm max. mounting depth
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3
NZM1/2-XV4
NZM3/4-XV4
NZM1/2-XV6
NZM3/4-XV6
261232
261234
260191
260193
Length 290 mm, can be cut to desired length
Length 425 mm, can be cut to desired length
CA08103003Z_MOEM2015-EN.book Seite 241 Donnerstag, 7. April 2016 12:02 12
Moeller® series
NZM circuit-breakers, switch-disconnectors
Main switch assembly kit, remote operator
Main switch assembly kit, remote operator
For use with Rated control voltage Part no.
U s
Article no.
V
Main switch assembly kit for IEC, UL/CSA
Equipment supplied
• Door coupling rotary handle with rotary drive
• NZM...-XV4 extension shaft
• External warning plate/marking plate in German/English
• Black and yellow lightning symbol
Protection class IP66 UL/CSA Type 4X, Type 12
With black door coupling rotary handle
Door interlock on OFF with max. 3 padlocks
Can also be modified in I position
After the door interlock is activated, must not be opened while on ON or
TRIP. Must only be opened on OFF
Can be modified such that it can be defeated from the outside using a screwdriver
Not defeated in the locked OFF position.
Can only be switched ON when the door is closed
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3 -
-
-
With red door coupling rotary handle for use of switch as emergency switching off device to IEC/EN 60204-1, VDE 0113 part 1
Door interlock on OFF with max. 3 padlocks
After the door interlock is activated, must not be opened while on ON or
TRIP. Must only be opened on OFF
Can be modified such that it can be defeated from the outside using a screwdriver
Not defeated in the locked OFF position.
Can only be switched ON when the door is closed
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3 -
-
-
Main switch assembly kit with additional rotary handle for IEC, UL/CSA
Equipment supplied
• Door coupling rotary handle with rotary drive
• Add-on rotary handle on switch with "Deliberate Action" operation as per NFPA79 and UL508A Part 2
• NZM1/2-XV4 shaft extension for mounting depth of 400 mm
• External warning plate/marking plate in German/English
• Black and yellow lightning symbol
Protection class IP66 UL/CSA Type 4X, Type 12
With black door coupling rotary handle
NZM1, N(S)1 Door interlock on OFF with max. 3 padlocks
With activated door interlock. Cannot be opened in ON, OFF, or TRIP. Can only be opened in RESET.
Can be modified such that it can be defeated from the outside using a screwdriver
Not defeated in the locked OFF position.
NZM2, N(S)2
NZM3, N(S)3 -
-
-
NZM1-XHB
266626
NZM2-XHB
266627
NZM3-XHB
266628
NZM1-XHBR
266632
NZM2-XHBR
266633
NZM3-XHBR
266634
NZM1-XHB-DA-NA
125958
NZM2-XHB-DA-NA
116897
NZM3-XHB-DA-NA
119000
With red door coupling rotary handle for use of switch as emergency switching off device
Door interlock on OFF with max. 3 padlocks
With activated door interlock. Cannot be opened in ON, OFF, or TRIP. Can only be opened in RESET.
Can be modified such that it can be defeated from the outside using a screwdriver
Not defeated in the locked OFF position.
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3 -
-
NZM1-XHB-DAR-NA
125959
NZM2-XHB-DAR-NA
116898
NZM3-XHB-DAR-NA
119001
Remote operator
For remote switching of circuit-breakers and switch-disconnectors.
ON and OFF switching and resetting by means of two-wire or three-wire control.
Local switching by hand possible.
Lockable in the 0 position of the remote operator with up to 3 padlocks (hasp thickness: 4 – 8 mm)
Closing delay 110 - 170 ms, Break time 110 - 170 ms
-
Sliding switch for "Auto" or "Manual"
Max. number auxiliary contacts: 2 standard auxiliary contacts,
1 trip-indicating auxiliary switches
NZM2, N(S)2
NZM2, N(S)2
208 - 240 V 50/60 Hz
24 - 30 V DC
NZM2-XRD208-240AC
115391
NZM2-XRD24-30DC
115393
Closing delay 60 - 100 ms, Break time 300 - 3000 ms
Synchronized
NZM3, N(S)3
NZM3, N(S)3
208 - 240 V 50/60 Hz
24 - 30 V DC
NZM3-XR208-240AC
259850
NZM3-XR24-30DC
259854
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 241
CA08103003Z_MOEM2015-EN.book Seite 241 Donnerstag, 7. April 2016 12:02 12
Moeller® series
NZM circuit-breakers, switch-disconnectors
Main switch assembly kit, remote operator
Main switch assembly kit, remote operator
For use with Rated control voltage Part no.
U s
Article no.
V
Main switch assembly kit for IEC, UL/CSA
Equipment supplied
• Door coupling rotary handle with rotary drive
• NZM...-XV4 extension shaft
• External warning plate/marking plate in German/English
• Black and yellow lightning symbol
Protection class IP66 UL/CSA Type 4X, Type 12
With black door coupling rotary handle
Door interlock on OFF with max. 3 padlocks
Can also be modified in I position
After the door interlock is activated, must not be opened while on ON or
TRIP. Must only be opened on OFF
Can be modified such that it can be defeated from the outside using a screwdriver
Not defeated in the locked OFF position.
Can only be switched ON when the door is closed
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3 -
-
-
With red door coupling rotary handle for use of switch as emergency switching off device to IEC/EN 60204-1, VDE 0113 part 1
Door interlock on OFF with max. 3 padlocks
After the door interlock is activated, must not be opened while on ON or
TRIP. Must only be opened on OFF
Can be modified such that it can be defeated from the outside using a screwdriver
Not defeated in the locked OFF position.
Can only be switched ON when the door is closed
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3 -
-
-
Main switch assembly kit with additional rotary handle for IEC, UL/CSA
Equipment supplied
• Door coupling rotary handle with rotary drive
• Add-on rotary handle on switch with "Deliberate Action" operation as per NFPA79 and UL508A Part 2
• NZM1/2-XV4 shaft extension for mounting depth of 400 mm
• External warning plate/marking plate in German/English
• Black and yellow lightning symbol
Protection class IP66 UL/CSA Type 4X, Type 12
With black door coupling rotary handle
NZM1, N(S)1 Door interlock on OFF with max. 3 padlocks
With activated door interlock. Cannot be opened in ON, OFF, or TRIP. Can only be opened in RESET.
Can be modified such that it can be defeated from the outside using a screwdriver
Not defeated in the locked OFF position.
NZM2, N(S)2
NZM3, N(S)3 -
-
-
NZM1-XHB
266626
NZM2-XHB
266627
NZM3-XHB
266628
NZM1-XHBR
266632
NZM2-XHBR
266633
NZM3-XHBR
266634
NZM1-XHB-DA-NA
125958
NZM2-XHB-DA-NA
116897
NZM3-XHB-DA-NA
119000
With red door coupling rotary handle for use of switch as emergency switching off device
Door interlock on OFF with max. 3 padlocks
With activated door interlock. Cannot be opened in ON, OFF, or TRIP. Can only be opened in RESET.
Can be modified such that it can be defeated from the outside using a screwdriver
Not defeated in the locked OFF position.
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3 -
-
NZM1-XHB-DAR-NA
125959
NZM2-XHB-DAR-NA
116898
NZM3-XHB-DAR-NA
119001
Remote operator
For remote switching of circuit-breakers and switch-disconnectors.
ON and OFF switching and resetting by means of two-wire or three-wire control.
Local switching by hand possible.
Lockable in the 0 position of the remote operator with up to 3 padlocks (hasp thickness: 4 – 8 mm)
Closing delay 110 - 170 ms, Break time 110 - 170 ms
-
Sliding switch for "Auto" or "Manual"
Max. number auxiliary contacts: 2 standard auxiliary contacts,
1 trip-indicating auxiliary switches
NZM2, N(S)2
NZM2, N(S)2
208 - 240 V 50/60 Hz
24 - 30 V DC
NZM2-XRD208-240AC
115391
NZM2-XRD24-30DC
115393
Closing delay 60 - 100 ms, Break time 300 - 3000 ms
Synchronized
NZM3, N(S)3
NZM3, N(S)3
208 - 240 V 50/60 Hz
24 - 30 V DC
NZM3-XR208-240AC
259850
NZM3-XR24-30DC
259854
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 242 Donnerstag, 7. April 2016 12:02 12
NZM circuit-breakers, switch-disconnectors
Diagnostics, communication
Diagnostics, communication
Description Part no.
Article no.
Diagnostics and configuration software for NZM and DMI (local)
PC software for direct connection to all NZM circuit-breakers with electronic releases (IEC and UL/CSA devices), including the connection cable required in order to connect to an NZM device.
NZM-XPC-KIT
265631
Moeller® series
Notes
Only in combination with circuitbreakers with electronic trip blocks.
Touch display with integrated controller BreakerVisu (HMI-PLC)
Visualize and log circuit-breaker and/or measuring device data
Read diagnostic memories
Create energy logs
Connect NZM using NZM-XSWD-704
Connect all NZM…-XMC-MB… measuring modules and NZM-XMC-TC-MB
Connection of IZMX16/40 using IZMX-MCAM
Connect IZM26… using IZM-MMINT
Connect PKE with XTUA or XTUWA using PKE-SWD-SP
Connect PKE with XTUACP or XTUWACP using PKE-SWD-CP
Connect RCCBs, MCBs, RCBOs using MCB-HK-SWD
Ethernet connection for display on web browsers
FTP connection for data transfers
Gateway function for forwarding data
Non-Eaton devices can be connected
Max. 8 devices via MODBUS RTU
3.5 Inch
Color display, TFT
NZM-XMC-MDISP35-MOD
172764
Max. 8 devices via SmartWire-DT
3.5 Inch
Color display, TFT
NZM-XMC-MDISP35-SWD
172765
Max. 32 devices via MODBUS RTU and/or max. 16 devices via
SmartWire-DT
7 Inch
Color display, TFT
NZM-XMC-MDISP70
172766
SmartWire-DT interface for NZM circuit-breakers
The module implements the data connection between the NZM2/3/
4 with electronic release and the SmartWire-DT.
• Status data NZM: ON/OFF/TRIPPED
• Load warnings
• Reason for last trip
• Actual current value in A
• Switch type
• Actual settings of the rotary coding switches
Measuring and communication module
For measuring current, voltage, power and energy.
The module has three built-in current transformers and three voltage taps, which are contacted with self-tapping screws, which penetrate the the cable insulation.
Power supply 24 VDC
Two SO pulse outputs
Modbus interface (Slave)
The total energy consumption value is permanently stored in the module.
Display device NZM-XMC-DISP can be connected for local indication of the readings.
NZM-XSWD-704
135530
NZM2-XMC-MB-250
156641
NZM2-XMC-MB
129961
NZM3-XMC-MB
129962
A connection cable (1.90 m) for the circuit-breaker and two NZM auxiliary contacts (1 x NO, 1 x NC) are included as standard.
The minimum clearances relative to the NZM circuit-breaker need to be maintained for installation.
The module can be installed on the input or outgoer side and can be set up using the Eaton Modbus
Configurator(www.eaton.eu).
CA08103003Z_MOEM2015-EN.book Seite 243 Donnerstag, 7. April 2016 12:02 12
NZM circuit-breakers, switch-disconnectors
Moeller® series
Description Part no.
Article no.
Measuring and communication module for external current transformers
For measuring current, voltage, power, and energy.
In addition, the module requires three current transformers and three voltage taps wired externally. X/5A standard current transformers rated for up to 6,300 A are suitable.
230 VAC power supply
2 configurable outputs (S0 pulse, alarm, etc.)
RS-485 Modbus port (slave)
The total energy consumption value will be stored in retentive memory on the module.
BreakerVisu displays (NZM-XMC-MDISP...) can be used for visualization and logging purposes.
Digital display device
For flush mounting on doors (connection to local display)
For all measuring and communication modules with a Modbus interface
Phase-specific indication of currents, voltages, power, and energy values
Pre-configured screens available
Cannot be combined with NZM-XMC-TC-MB
Front dimensions 96 x 96 mm
Front cutout 92 x 92 mm
NZM-XMC-TC-MB
169832
NZM-XMC-DISP
129967
Diagnostics, communication
Notes
The minimum clearances relative to the NZM circuit-breaker need to be maintained for installation.
The module can be installed on the input or outgoer side, as well as on a top hat DIN rail.
The Eaton Modbus Configurator
(www.eaton.eu) can be used to set up the module.
Cannot be combined with NZM-XMC-
DISP display device.
Connection to NZM...XMC-MB using four-wire data cable (not included as standard).
Cannot be combined with NZM-XMC-
TC-MB.
Number of poles Rated current = rated uninterrupted current
I n
= I u
A
I r
A
Setting range
Overload trip Short-circuit releases
I i
A
I >
Circuit-breakers with earth-fault release
For equipment with power electronics, such as inverters and variable frequency drives
Not UL/CSA approved
Suitability for the application in three-phase systems
Rated operating voltage 400 V 50 Hz (+/- 10 %)
Rated fault current I
Δ n
= 0.03 A
Internal power supply U e
= 50 – 400 V
AC/DC sensitive according to core-balance principle in range of 0 – 100 kHz residual-current frequency.
Prefabricated combination of current-limiting circuit-breaker and residual current device
Adjusting buttons can be sealed.
3 pole 125
160
200
250
100 - 125
125 - 160
160 - 200
200 - 250
750 - 1250
960 - 1600
1200 - 2000
1500 - 2500
High switching capacity 150 kA
Part no.
Article no.
Screw connection
NZMH2-A125-FIA30
129710
NZMH2-A160-FIA30
112627
NZMH2-A200-FIA30
112628
NZMH2-A250-FIA30
112629
EATON CA08103003Z-EN-INT Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN 243
CA08103003Z_MOEM2015-EN.book Seite 243 Donnerstag, 7. April 2016 12:02 12
NZM circuit-breakers, switch-disconnectors
Moeller® series
Description Part no.
Article no.
Measuring and communication module for external current transformers
For measuring current, voltage, power, and energy.
In addition, the module requires three current transformers and three voltage taps wired externally. X/5A standard current transformers rated for up to 6,300 A are suitable.
230 VAC power supply
2 configurable outputs (S0 pulse, alarm, etc.)
RS-485 Modbus port (slave)
The total energy consumption value will be stored in retentive memory on the module.
BreakerVisu displays (NZM-XMC-MDISP...) can be used for visualization and logging purposes.
Digital display device
For flush mounting on doors (connection to local display)
For all measuring and communication modules with a Modbus interface
Phase-specific indication of currents, voltages, power, and energy values
Pre-configured screens available
Cannot be combined with NZM-XMC-TC-MB
Front dimensions 96 x 96 mm
Front cutout 92 x 92 mm
NZM-XMC-TC-MB
169832
NZM-XMC-DISP
129967
Diagnostics, communication
Notes
The minimum clearances relative to the NZM circuit-breaker need to be maintained for installation.
The module can be installed on the input or outgoer side, as well as on a top hat DIN rail.
The Eaton Modbus Configurator
(www.eaton.eu) can be used to set up the module.
Cannot be combined with NZM-XMC-
DISP display device.
Connection to NZM...XMC-MB using four-wire data cable (not included as standard).
Cannot be combined with NZM-XMC-
TC-MB.
Number of poles Rated current = rated uninterrupted current
I n
= I u
A
I r
A
Setting range
Overload trip Short-circuit releases
I i
A
I >
Circuit-breakers with earth-fault release
For equipment with power electronics, such as inverters and variable frequency drives
Not UL/CSA approved
Suitability for the application in three-phase systems
Rated operating voltage 400 V 50 Hz (+/- 10 %)
Rated fault current I
Δ n
= 0.03 A
Internal power supply U e
= 50 – 400 V
AC/DC sensitive according to core-balance principle in range of 0 – 100 kHz residual-current frequency.
Prefabricated combination of current-limiting circuit-breaker and residual current device
Adjusting buttons can be sealed.
3 pole 125
160
200
250
100 - 125
125 - 160
160 - 200
200 - 250
750 - 1250
960 - 1600
1200 - 2000
1500 - 2500
High switching capacity 150 kA
Part no.
Article no.
Screw connection
NZMH2-A125-FIA30
129710
NZMH2-A160-FIA30
112627
NZMH2-A200-FIA30
112628
NZMH2-A250-FIA30
112629
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
Hydraulic magnetic circuit breakers to design a more reliable machine
Catalog download: www.eaton.eu/HMCB
Hydraulic magnetic circuit breakers offer optimal protection for your equipment avoiding risks of unexpected tripping due to starting current peaks (motor) or caused by inductive circuits with long cables: it therefore also enables cable cross-section optimization.
It’s difficult to get low DC voltage on long cables right. This can be because of T° variation modifying circuit resistivity, interferences caused by the long wiring acting like an antenna or just a peak generated by inductive circuits or motor start. Configuration like this can often lead to unexpected tripping of the circuit protection.
By design, this technology offers an accurate, robust and repeatable means of protecting your electrical equipment without creating a nuisance tripping. The benefits of Eaton Heinemann's hydraulic magnetic circuits breakers include the ability to manage current peaks generated by motor starts, a fixed tripping point insensitive to ambient T° variations, proven resistance to shocks and vibrations and no derating over time and usage.
244 EATON CA08103003Z-EN-INT
Special tripping characteristics prevent the nuisance tripping
What makes this technology different
Triggering of the mechanism in hydraulic magnetic circuit breakers is based on the solenoid principle. The coil is wired around an hermetic tube containing a movable core, damped with silicon oil and held by a spring, and moves by the attraction of a magnetic field. The combined action of the spring and oil's viscosity gives a specific dynamic to the core's movement and allows special tripping characteristics that prevent the nuisance tripping while ensuring accurate and repeatable protection over time and usage.
In the event of overload or fault condition, the increase of the current in the coil makes the core moves toward a pole piece: the reluctance of the magnetic circuit that contains the armature is then reduced. Once the core reaches the pole piece, the armature is attracted and the mechanism of the breaker trips, causing the separation of contact. In the event of a short circuit, the magnetic field generated by the current in the coil immediately attracts the armature without any delay. This is what makes the technology different: two different actions using only one technology and the principles of magnetism.
ADS – DIN mounted Hydraulic magnetic circuit breaker
The ADS Supplementary Protector is a dual rated product for both AC and DC supplies, in accordance with UL 1077, CSA 22.2, VDE 0660 and IEC 60947-2 standards.
It is to be applied in conjunction with a branch protector (if branch protection is required) and can be a replacement for similarly applied fuses. Its advantages over fuses are that it is resettable and the device’s status is easily and clearly identified by the position of the handle.
In addition to this, the user is able to select a device that precisely fits the application (of which here are many) due to the availability of a wide range of current ratings, three levels of inrush tolerance (8 x, 15 x, 22 x for 50 Hz) and flexible time characteristic curves (Short, Medium and Long Delay).
In addition to this, the ADS’s protection performance is not adversely affected and is resistant to abnormal or changing ambient temperatures or even excessive environmental factors.
The design allows it to be utilized in environments that can expose it to fungus, shock or out of the ordinary vibration.
Accessories
The large choice of internal circuits, handles, terminals, auxiliary contacts, mounting styles and range of protections makes those circuit breakers the ideal choice for demanding applications.
EATON CA08103003Z-EN-INT 245
Features, Benefits and Functions
• Used to provide overcurrent protection where branch protection (for example UL 489 MCCB) is already provided or not required
• Installed as a component within or part of an appliance or a piece of electrical equipment
• Ideal replacement for uses that are applied as a supplementary protector i.e., in addition to branch protection
(if required)
• Light Gray case with White handle, that is marked “O” for
OFF and “I” for ON
• Environmental, Vibration and Shock Resistant: Mil-spec qualification for fungus resistance, humidity, salt spray resistance and shock vibration resistance
• Heat Induced Nuisance Tripping Eliminated:
The protector is designed to “hold in” at 100 % continuous rated current, regardless of ambient temperatures from
- 40 °C to + 85 °C
• Immediate Reset After Trip:
The circuit breaker can be reset (closed) immediately after an overcurrent trip without a “cooling off” period
• 1/2 Cycle High Inrush Tolerance – 8 x (standard),
15 x and 22 x for 50 Hz (20 - 18 - 25 x for 60 Hz):
The protector is available with different levels of tolerance to 1/2 cycle current pikes – standard tolerance is 8 x the continuous current rating; in addition 18 x and 25 x are also available
• Overcurrent curves, Long, Medium or Short Delay:
Time characteristic curves are available as Short, Medium and Long Delay
• Integral Auxiliary Switch (optional selection):
One auxiliary switch (NO or NC) can be factory installed per pole – a separate pole for auxiliary is NOT required.
• Precise Overcurrent Calibration:
The protector can be precisely calibrated to a wide variety of current ratings, from 0.1 to 63 continuous amperes
• DIN Rail Mountable:
The protector can be easily mounted, utilizing its quick release spring clip to attach it to a 35 mm DIN rail.
• Standards and Certifications
– UL recognized under UL 1077
– UL File No. E69553
– CSA 22.2 No. 235
– IEC 60947-2
– CE marked
– CCC marked
Inrush
ADS circuit breakers are available with various levels of highinrush currents avoiding nuisance trip during short starting periods at turn on.
In case of motor protections for example causing a steep wave front transient of very high current amplitude and short duration of overload, the breaker does not trip.
By using AS high-inrush types, unnecessary and dangerous overcalibrations involving use of thicker cables or wires can be avoided, thus saving energy and money.
The magnetic shunt used offers maximum possibilities on half wave which is 10 ms when frequency is 50 Hz.
At 60 Hz half wave periode is 8 ms based on value of 1800 % instead of 1500 % and 2500 % instead of 2200 % at 50 Hz.
246 EATON CA08103003Z-EN-INT
Medium delay
Approvals
VDE 60947-2 : 80 VDC / 400 VAC
1-2 Poles
63 A maxi
Ic 1500 A
UL 1077 : 65 VDC / 250 – 277 VAC
1-4 Poles
50 A maxi
Ic 5000 A
In.% 135 200 300 400 500 600 700 800 900 1000 1100 1200
MAX 85.0 20.0 4.50 2.00 1.20 1.00 .750 .600 .450 .290 – –
MIN 8.0 2.5 .85 .45 .25 .13 .045 .012 .010 .010 – –
Ordering data
30
32
35
20
25
15
16
40
50
63
10
12
13
7
8
5
6
1.6
2
2.5
3
3.5
4
Amps
0.16
0.25
0.5
0.75
1
1.5
15x InRush (50 Hz) – Medium Delay Curve 20 (AC / DC)
Part no.
1 Pole
AD1S-Y50x-1
AD1S-Y50x-2
AD1S-Y50x-3
AD1S-Y50x-4
AD1S-Y50x-5
AD1S-Y50x-6
AD1S-Y50x-7
AD1S-Y50x-8
AD1S-Y50x-9
AD1S-Y50x-10
AD1S-Y50x-11
AD1S-Y50x-12
AD1S-Y50x-13
AD1S-Y50x-14
AD1S-Y50x-15
AD1S-Y50x-16
AD1S-Y50x-17
AD1S-Y50x-18
AD1S-Y50x-19
AD1S-Y50x-20
AD1S-Y50x-21
AD1S-Y50x-22
AD1S-Y50x-23
AD1S-Y50x-24
AD1S-Y50x-25
AD1S-Y50x-26
AD1S-Y50x-27
AD1S-Y50x-28
AD1S-Y50x-29
Part no.
2 Poles
AD2S-Y50x-1
AD2S-Y50x-2
AD2S-Y50x-3
AD2S-Y50x-4
AD2S-Y50x-5
AD2S-Y50x-6
AD2S-Y50x-7
AD2S-Y50x-8
AD2S-Y50x-9
AD2S-Y50x-10
AD2S-Y50x-11
AD2S-Y50x-12
AD2S-Y50x-13
AD2S-Y50x-14
AD2S-Y50x-15
AD2S-Y50x-16
AD2S-Y50x-17
AD2S-Y50x-18
AD2S-Y50x-19
AD2S-Y50x-20
AD2S-Y50x-21
AD2S-Y50x-22
AD2S-Y50x-23
AD2S-Y50x-24
AD2S-Y50x-25
AD2S-Y50x-26
AD2S-Y50x-27
AD2S-Y50x-28
AD2S-Y50x-29
This is only given as example but large choice of internal circuits, tripping characteristics, Inrush are available.
Information on: www.eaton.eu/HMCB
Part no.
3 Poles
AD3S-Y50x-1
AD3S-Y50x-2
AD3S-Y50x-3
AD3S-Y50x-4
AD3S-Y50x-5
AD3S-Y50x-6
AD3S-Y50x-7
AD3S-Y50x-8
AD3S-Y50x-9
AD3S-Y50x-10
AD3S-Y50x-11
AD3S-Y50x-12
AD3S-Y50x-13
AD3S-Y50x-14
AD3S-Y50x-15
AD3S-Y50x-16
AD3S-Y50x-17
AD3S-Y50x-18
AD3S-Y50x-19
AD3S-Y50x-20
AD3S-Y50x-21
AD3S-Y50x-22
AD3S-Y50x-23
AD3S-Y50x-24
AD3S-Y50x-25
AD3S-Y50x-26
AD3S-Y50x-27
AD3S-Y50x-28
AD3S-Y50x-29
Part no.
4 Poles
AD4S-Y50x-1
AD4S-Y50x-2
AD4S-Y50x-3
AD4S-Y50x-4
AD4S-Y50x-5
AD4S-Y50x-6
AD4S-Y50x-7
AD4S-Y50x-8
AD4S-Y50x-9
AD4S-Y50x-10
AD4S-Y50x-11
AD4S-Y50x-12
AD4S-Y50x-13
AD4S-Y50x-14
AD4S-Y50x-15
AD4S-Y50x-16
AD4S-Y50x-17
AD4S-Y50x-18
AD4S-Y50x-19
AD4S-Y50x-20
AD4S-Y50x-21
AD4S-Y50x-22
AD4S-Y50x-23
AD4S-Y50x-24
AD4S-Y50x-25
AD4S-Y50x-26
AD4S-Y50x-27
AD4S-Y50x-28
AD4S-Y50x-29
0 : Without Aux Contact
X choice 1 : With Aux contact NO
2 : With Aux contact NC
”Aux contact on first pole per default, but other configuration are possible“.
EATON CA08103003Z-EN-INT 247
248
up to 25 kA
to IEC/EN 60947-2
Protection for all applications:
Safety up to 125 A
Industry, system builders and the trade sector worldwide place their trust in Eaton products and solutions. Tested quality, approvals and shipping register classifications vouch for the functional scope and reliability of xEffect industrial miniature circuit breakers being suitable for world markets. In conjunction with the versatile complete range of modular installation devices and accessories, the user is provided with more options for solving complex technical problems.
Eaton offers a comprehensive range of residual current devices for residual current protection of persons against electrical shock and to protect installations against fire.
www.eaton.eu/cp
EATON CA08103003Z-EN-INT
When it comes to protection and switching, industry in many countries relies on Eaton products
Powerful range for machine and system builders
Optimum product quality and tested reliability and safety stand for optimum protection of personnel, installations and plant.
Approvals in many countries confirm that Eaton builds its products to comply with the latest national and international regulations. The high IEC/EN 60947-2 switching capacity of 15 kA with FAZ and 15 to 25 kA with AZ and FAZT, as well as effective current limitation and selectivity provide optimum system protection and maximum availability.
The xEffect Industrial FAZ is available with B, C and D characteristic to IEC/EN 60898-1. An additional special characteristic has become necessary for effective protection, due to the growing proportion of sensitive electronics. The Z characteristic with a short-circuit response current of 2 to 3 x I n
offers quick overload protection reaction for this purpose.
The K characteristic with a high short-circuit response current of 8 to 12 x I n
prevents nuisance tripping during connection of three-phase loads.
The S characteristic with a limited response current of 13 to
17 x I n
has become established in system building.
Attention
protects
warns
monitors
Digital residual-current protection designed to keep your equipment running
Whether using three-pole or four-pole standards, Eaton‘s new digital residual current devices are powerful multifunctional
“bodyguards” designed to ensure safety in distributed environments and work with a wide variety of machines and systems. They are as intelligent as they are vigilant, and will prevent even the smallest fault current from passing. Moreover, these digital guardians will immediately indicate any inconsistencies. This advance warning function is designed to enable operators to intervene and ensure that operations keep running smoothly. If there really is any danger, the digital residual current device will trip with utmost precision – much more accurately, in fact, than conventional analog circuit breakers.
This high-precision tripping behavior keeps accidental tripping to a minimum and will improve the continuity of your operations.
Gradual fault warning
Digital circuit breakers use a potential-free switching contact to communicate with their surroundings. This means that it will not be necessary to run all the way to the distribution board to figure out what the system‘s status is, as an automatic advance warning can be issued when I
> 0,3 x I
n
, for example. From driving external lights and/or buzzers to establishing a connection to monitoring systems able to send SMS notifications to your cell phone: the sky's the limit when it comes to the ways you can use this option.
Continuous electrical system monitoring
An LED traffic light indicator on the device makes it possible to immediately determine the system‘s status locally.
Green = Normal range
Yellow = The leakage current or fault current is 30 – 50 % of I
n
Red = The leakage current or fault current is > 50 % of I
n
The device will trip very closely to the 100 % value.
.
EATON CA08103003Z-EN-INT 249
Combine convenience with efficiency and safety The key to effortless connections and smart communication
The test button on the digital residual current circuit breaker only needs to be pressed once a year.
In addition, an integrated overload functionality makes it possible to eliminate the need for a thermal back-up fuse for the residual current device, while an integrated short time delay (type G) ensures that it will not trip in response to short transient overvoltages
(e.g., caused by a lightning strike). The upper and lower ring tongue/spring clamp double terminals provide added convenience, matched by the added safety provided by the accessories for the device. Both the integrated red/green position indicator and the white/blue tripped current indicator provide all the necessary information right on the unit. Finally, a wide range of accessories, such as the Z-HK, can be retrofitted, and the fact that the device can be sealed provides even greater levels of safety.
The SmartWire-DT auxiliary contact module makes it possible to easily connect a circuit breaker, fault current switch or combination protective switch to the SmartWire DT line using plug-in connection and to in this way easily and quickly integrate the protective switching devices. This eliminates the need for an I/O interface, with the required information being implemented in controllers and drives. SmartWire-DT auxiliary contacts can be used to relay the ON, OFF, and Tripped (by a fault) states.
Flexibility using modular installation devices
Lightning and surge protection Practical complete product range
Eaton offers a broad range of modular installation devices for the control circuit and for switching, as well as for signalling and alarms. All these devices are suitable for DIN-rail mounting and offer tangible installation and wiring benefits for industrial applications.
The lightning and surge protective device SPB-12/280 is a combined lightning and surge arrester (arrester class
B+C) in just one space unit. The world’s first complies with required lighting surge currents of protection classes
III and IV of the IEC 62305 and thus achieves the required minimum lightning surge current of 12.5 kA per protected circuit specified in standard IEC 60364-5-
53. The transient voltage surge suppression is achieved with a nominal impulse discharge current of 25 kA that greatly exceeds the minimum requirement of
5 kA per protected circuit.
The comprehensive range is complemented by equipment required in industrial installations, such as DIN-rail mounting Schuko sockets, ammeters and voltmeters, power consumption and operational hours meters, as well as analog and digital timers, staircase timers, light intensity switches, buzzers and bells. Eaton offers an extensive product range for the perfect installation, all from a single source.
250 EATON CA08103003Z-EN-INT
Areas of
Application
Light and wall socket circuits with resistive loads
Characteristic
B
Inductive, capacitive loads
M
Large transformers, motors with heavy starting duty, large groups of light elements
M
Semiconductor protection, high-impedance cables
C
D
Z
Motors, transformers, upstream electronics
M Electronics
Contactors, motors, control transformers
K M
K
S
Tripping characteristics of the xEffect Industrial FAZ minature circuit breaker
The versatile, individual tripping
characteristics offer cable protection, individual device protection and protection in the control circuit.
The high levels of rated switching capacity from 10 to 25 kA, as well as effective current limitation and selectivity ensure optimum system protection and availability.
The B characteristic is utilised in the
protection of light and wall socket circuits.
The C characteristic is utilised wherever operational current peaks and other surges occur that must not lead to tripping.
For large transformers, motors with heavy starting duty or extensive groups of light elements, the D characteristic is the correct solution.
The characteristics are available on single- and multi-pole component versions in all the ratings up to 63 A.
Enhanced cable protection at high operational continuity
The K characteristic trips out at short circuits of 8 to 12 times rated current and is utilised wherever operational current peaks and other current surges can occur, but must not cause tripping.
Thus it lies in the upper reach of the C and in the lower reach of the D
characteristic. This allows motors, capacitors, welding transformers and electronically controlled upstream devices to be connected in the optimum way. The K characteristic from Eaton offers enhanced cable protection due to its narrower bimetal tripping range for overload protection.
Safety for control circuits
The control circuit protective switch with S characteristic is designed for the protection of control circuits with high inrush currents. At 13 to 17 x I n
, the magnitude of the short-circuit current here lies in a limited band of the D
characteristic above the starting peak of the typical control transformer. Thus, unintentional tripping is prevented by the S characteristic device, which is tested to IEC/EN 60947-2. Compliant with this Standard, the control circuit protective switch only permits an overload of between 5 and 30 %.
Rapid-response protection for electronics
Electronic components and devices can be destroyed by even small current surges. The protective switches xEffect Industrial FAZ with Z characteristic trip out instantly even at surges of 2 to 3 times rated current. This property also renders these protective circuit breakers suitable for the protection of highimpedance cables.
EATON CA08103003Z-EN-INT 251
CA08103003Z_MOEM2015-EN.book Seite 252 Donnerstag, 7. April 2016 12:02 12
Miniature circuit-breaker, residual current circuit-breaker
System overview
System overview
9
1
1
9
FAZ-2 1
7
FAZ-3
3
FAZ-2
3
13
4
11
1
2
11
5
10
FI-40
5
FIP-4
11
12
6
6
8
6
6
Moeller® series
4
3
2
1
1
6
5
FAZ miniature circuit-breakers 7
FAZT miniature circuit-breakers
FAZ-PN miniature circuit-breaker 9
8
FBSmV residual-current protective modules for fitting to FAZ 10
FRBmM combination switch 11
FRCmM residual current circuit breaker
AZ miniature circuit-breakers
12
13
EATON CA08103003Z-EN-INT
FAZ auxiliary contact module or SmartWire-DT connection module
AZ auxiliary contacts
FAZ voltage releases
AZ voltage releases
Remote switching module
FBHmV residual-current protective modules for fitting to AZ
Residual-current auxiliary contact module or SmartWire-DT connection module
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 253 Donnerstag, 7. April 2016 12:02 12
Moeller® series
FAZ miniature circuit-breakers
Circuit-breaker
FAZ miniature circuit-breakers
Rated current Switching capacity
(IEC/EN 60947-2)
I n
A kA
FAZ miniature circuit-breakers
15
16
20
25
32
10
12
13
40
50
63
5
6
8
3
3.5
4
1.6
2
2.5
0.5
0.75
1
1.5
5
6
8
3
3.5
4
1.5
1.6
2
2.5
(please enquire for circuit-breakers with 3+N and 4 poles)
Characteristic B
Instantaneous release response current
3 - 5 x In
1 15
15
15
15
15
15
15
15
15
15
15
15
16
20
25
32
10
12
13
15
15
15
15
15
15
15
15
40
50
63
15
15
15
Characteristic C
Instantaneous release response current
5 - 10 x In
0.16
0.25
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
1 pole
Part no.
FAZ-B1/1
FAZ-B1,5/1
FAZ-B1,6/1
FAZ-B2/1
FAZ-B2,5/1
FAZ-B3/1
FAZ-B3,5/1
FAZ-B4/1
FAZ-B5/1
FAZ-B6/1
FAZ-B8/1
FAZ-B10/1
FAZ-B12/1
FAZ-B13/1
FAZ-B15/1
FAZ-B16/1
FAZ-B20/1
FAZ-B25/1
FAZ-B32/1
FAZ-B40/1
FAZ-B50/1
FAZ-B63/1
FAZ-C10/1
FAZ-C12/1
FAZ-C13/1
FAZ-C15/1
FAZ-C16/1
FAZ-C20/1
FAZ-C25/1
FAZ-C32/1
FAZ-C40/1
FAZ-C50/1
FAZ-C63/1
FAZ-C0,16/1
FAZ-C0,25/1
FAZ-C0,5/1
FAZ-C0,75/1
FAZ-C1/1
FAZ-C1,5/1
FAZ-C1,6/1
FAZ-C2/1
FAZ-C2,5/1
FAZ-C3/1
FAZ-C3,5/1
FAZ-C4/1
FAZ-C5/1
FAZ-C6/1
FAZ-C8/1
1 pole+N
Article no.
Part no.
278531
278532
278533
278534
278535
278536
278537
278538
278539
278540
278541
278520
278521
278522
278523
278524
278525
278526
278527
278528
278529
278530
278554
278555
278556
278557
278558
278559
278560
278561
278562
278563
278564
278565
278566
278567
278542
278543
278544
278545
278546
278547
278548
278549
278550
278551
278552
278553
2 pole
Article no.
Part no.
FAZ-B1/1N
FAZ-B1,5/1N
FAZ-B1,6/1N
FAZ-B2/1N
FAZ-B2,5/1N
FAZ-B3/1N
FAZ-B3,5/1N
FAZ-B4/1N
FAZ-B5/1N
FAZ-B6/1N
FAZ-B8/1N
FAZ-B10/1N
FAZ-B12/1N
FAZ-B13/1N
FAZ-B15/1N
FAZ-B16/1N
FAZ-B20/1N
FAZ-B25/1N
FAZ-B32/1N
FAZ-B40/1N
FAZ-B50/1N
FAZ-B63/1N
278644
278645
278646
278647
278648
278649
278650
278651
278652
278653
278654
278633
278634
278635
278636
278637
278638
278639
278640
278641
278642
278643
3 pole
Article no.
Part no.
FAZ-C0,16/1N 278655
FAZ-C0,25/1N 278656
FAZ-C0,5/1N 278657
FAZ-C0,75/1N 278658
FAZ-C1/1N 278659
FAZ-C1,5/1N
FAZ-C1,6/1N
FAZ-C2/1N
FAZ-C2,5/1N
278660
278661
278662
278663
FAZ-C3/1N
FAZ-C3,5/1N
FAZ-C4/1N
FAZ-C5/1N
FAZ-C6/1N
FAZ-C8/1N
278664
278665
278666
278667
278668
278669
FAZ-C10/1N
FAZ-C12/1N
FAZ-C13/1N
FAZ-C15/1N
FAZ-C16/1N
FAZ-C20/1N
FAZ-C25/1N
FAZ-C32/1N
FAZ-C40/1N
FAZ-C50/1N
FAZ-C63/1N
278670
278671
278672
278673
278674
278675
278676
278677
278678
278679
278680
EATON CORPORATION CA08103003Z-EN
FAZ-C0,16/2 278741
FAZ-C0,25/2 278742
FAZ-C0,5/2 278743
FAZ-C0,75/2 278744
FAZ-C1/2 278745
FAZ-C1,5/2 278746
FAZ-C1,6/2 278747
FAZ-C2/2 278748
FAZ-C2,5/2 278749
FAZ-C3/2 278750
FAZ-C3,5/2 278751
FAZ-C4/2
FAZ-C5/2
FAZ-C6/2
FAZ-C8/2
278752
278753
278754
278755
FAZ-C10/2
FAZ-C12/2
FAZ-C13/2
FAZ-C15/2
FAZ-C16/2
FAZ-C20/2
FAZ-C25/2
FAZ-C32/2
278756
278757
278758
278759
278760
278761
278762
278763
FAZ-C40/2
FAZ-C50/2
FAZ-C63/2
278764
278765
278766
FAZ-B1/2 278719
FAZ-B1,5/2 278720
FAZ-B1,6/2 278721
FAZ-B2/2 278722
FAZ-B2,5/2 278723
FAZ-B3/2 278724
FAZ-B3,5/2 278725
FAZ-B4/2
FAZ-B5/2
FAZ-B6/2
FAZ-B8/2
278726
278727
278728
278729
FAZ-B10/2
FAZ-B12/2
FAZ-B13/2
FAZ-B15/2
FAZ-B16/2
FAZ-B20/2
FAZ-B25/2
FAZ-B32/2
278730
278731
278732
278733
278734
278735
278736
278737
FAZ-B40/2
FAZ-B50/2
FAZ-B63/2
278738
278739
278740
FAZ-B1/3
FAZ-B1,5/3
FAZ-B1,6/3
FAZ-B2/3
FAZ-B2,5/3
FAZ-B3/3
FAZ-B3,5/3
FAZ-B4/3
FAZ-B5/3
FAZ-B6/3
FAZ-B8/3
FAZ-B10/3
FAZ-B12/3
FAZ-B13/3
FAZ-B15/3
FAZ-B16/3
FAZ-B20/3
FAZ-B25/3
FAZ-B32/3
FAZ-B40/3
FAZ-B50/3
FAZ-B63/3
Article no.
278866
278867
278868
278869
278870
278871
278872
278873
278874
278875
278876
278877
278878
278879
278854
278855
278856
278857
278858
278859
278860
278861
278862
278863
278864
278865
253
FAZ-C10/3
FAZ-C12/3
FAZ-C13/3
FAZ-C15/3
FAZ-C16/3
FAZ-C20/3
FAZ-C25/3
FAZ-C32/3
FAZ-C40/3
FAZ-C50/3
FAZ-C63/3
FAZ-C0,16/3
FAZ-C0,25/3
FAZ-C0,5/3
FAZ-C0,75/3
FAZ-C1/3
FAZ-C1,5/3
FAZ-C1,6/3
FAZ-C2/3
FAZ-C2,5/3
FAZ-C3/3
FAZ-C3,5/3
FAZ-C4/3
FAZ-C5/3
FAZ-C6/3
FAZ-C8/3
278843
278844
278845
278846
278847
278848
278849
278850
278851
278852
278853
278832
278833
278834
278835
278836
278837
278838
278839
278840
278841
278842
CA08103003Z_MOEM2015-EN.book Seite 253 Donnerstag, 7. April 2016 12:02 12
Moeller® series
FAZ miniature circuit-breakers
Circuit-breaker
FAZ miniature circuit-breakers
Rated current Switching capacity
(IEC/EN 60947-2)
I n
A kA
FAZ miniature circuit-breakers
15
16
20
25
32
10
12
13
40
50
63
5
6
8
3
3.5
4
1.6
2
2.5
0.5
0.75
1
1.5
5
6
8
3
3.5
4
1.5
1.6
2
2.5
(please enquire for circuit-breakers with 3+N and 4 poles)
Characteristic B
Instantaneous release response current
3 - 5 x In
1 15
15
15
15
15
15
15
15
15
15
15
15
16
20
25
32
10
12
13
15
15
15
15
15
15
15
15
40
50
63
15
15
15
Characteristic C
Instantaneous release response current
5 - 10 x In
0.16
0.25
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
1 pole
Part no.
FAZ-B1/1
FAZ-B1,5/1
FAZ-B1,6/1
FAZ-B2/1
FAZ-B2,5/1
FAZ-B3/1
FAZ-B3,5/1
FAZ-B4/1
FAZ-B5/1
FAZ-B6/1
FAZ-B8/1
FAZ-B10/1
FAZ-B12/1
FAZ-B13/1
FAZ-B15/1
FAZ-B16/1
FAZ-B20/1
FAZ-B25/1
FAZ-B32/1
FAZ-B40/1
FAZ-B50/1
FAZ-B63/1
FAZ-C10/1
FAZ-C12/1
FAZ-C13/1
FAZ-C15/1
FAZ-C16/1
FAZ-C20/1
FAZ-C25/1
FAZ-C32/1
FAZ-C40/1
FAZ-C50/1
FAZ-C63/1
FAZ-C0,16/1
FAZ-C0,25/1
FAZ-C0,5/1
FAZ-C0,75/1
FAZ-C1/1
FAZ-C1,5/1
FAZ-C1,6/1
FAZ-C2/1
FAZ-C2,5/1
FAZ-C3/1
FAZ-C3,5/1
FAZ-C4/1
FAZ-C5/1
FAZ-C6/1
FAZ-C8/1
Complete assortment -> www.eaton.eu/ecat
1 pole+N
Article no.
Part no.
278531
278532
278533
278534
278535
278536
278537
278538
278539
278540
278541
278520
278521
278522
278523
278524
278525
278526
278527
278528
278529
278530
278554
278555
278556
278557
278558
278559
278560
278561
278562
278563
278564
278565
278566
278567
278542
278543
278544
278545
278546
278547
278548
278549
278550
278551
278552
278553
2 pole
Article no.
Part no.
FAZ-B1/1N 278633
FAZ-B1,5/1N 278634
FAZ-B1,6/1N 278635
FAZ-B2/1N 278636
FAZ-B2,5/1N 278637
FAZ-B3/1N 278638
FAZ-B3,5/1N 278639
FAZ-B4/1N
FAZ-B5/1N
FAZ-B6/1N
FAZ-B8/1N
278640
278641
278642
278643
FAZ-B10/1N
FAZ-B12/1N
FAZ-B13/1N
FAZ-B15/1N
FAZ-B16/1N
FAZ-B20/1N
FAZ-B25/1N
FAZ-B32/1N
278644
278645
278646
278647
278648
278649
278650
278651
FAZ-B40/1N
FAZ-B50/1N
FAZ-B63/1N
278652
278653
278654
3 pole
Article no.
Part no.
FAZ-C0,16/1N 278655
FAZ-C0,25/1N 278656
FAZ-C0,5/1N 278657
FAZ-C0,75/1N 278658
FAZ-C1/1N 278659
FAZ-C1,5/1N 278660
FAZ-C1,6/1N 278661
FAZ-C2/1N 278662
FAZ-C2,5/1N 278663
FAZ-C3/1N 278664
FAZ-C3,5/1N 278665
FAZ-C4/1N
FAZ-C5/1N
FAZ-C6/1N
FAZ-C8/1N
278666
278667
278668
278669
FAZ-C10/1N
FAZ-C12/1N
FAZ-C13/1N
FAZ-C15/1N
FAZ-C16/1N
FAZ-C20/1N
FAZ-C25/1N
FAZ-C32/1N
278670
278671
278672
278673
278674
278675
278676
278677
FAZ-C40/1N
FAZ-C50/1N
FAZ-C63/1N
278678
278679
278680
EATON CA08103003Z-EN-INT
FAZ-C0,16/2 278741
FAZ-C0,25/2 278742
FAZ-C0,5/2 278743
FAZ-C0,75/2 278744
FAZ-C1/2 278745
FAZ-C1,5/2 278746
FAZ-C1,6/2 278747
FAZ-C2/2 278748
FAZ-C2,5/2 278749
FAZ-C3/2 278750
FAZ-C3,5/2 278751
FAZ-C4/2
FAZ-C5/2
FAZ-C6/2
FAZ-C8/2
278752
278753
278754
278755
FAZ-C10/2
FAZ-C12/2
FAZ-C13/2
FAZ-C15/2
FAZ-C16/2
FAZ-C20/2
FAZ-C25/2
FAZ-C32/2
278756
278757
278758
278759
278760
278761
278762
278763
FAZ-C40/2
FAZ-C50/2
FAZ-C63/2
278764
278765
278766
FAZ-B1/2 278719
FAZ-B1,5/2 278720
FAZ-B1,6/2 278721
FAZ-B2/2 278722
FAZ-B2,5/2 278723
FAZ-B3/2 278724
FAZ-B3,5/2 278725
FAZ-B4/2
FAZ-B5/2
FAZ-B6/2
FAZ-B8/2
278726
278727
278728
278729
FAZ-B10/2
FAZ-B12/2
FAZ-B13/2
FAZ-B15/2
FAZ-B16/2
FAZ-B20/2
FAZ-B25/2
FAZ-B32/2
278730
278731
278732
278733
278734
278735
278736
278737
FAZ-B40/2
FAZ-B50/2
FAZ-B63/2
278738
278739
278740
FAZ-B1/3
FAZ-B1,5/3
FAZ-B1,6/3
FAZ-B2/3
FAZ-B2,5/3
FAZ-B3/3
FAZ-B3,5/3
FAZ-B4/3
FAZ-B5/3
FAZ-B6/3
FAZ-B8/3
FAZ-B10/3
FAZ-B12/3
FAZ-B13/3
FAZ-B15/3
FAZ-B16/3
FAZ-B20/3
FAZ-B25/3
FAZ-B32/3
FAZ-B40/3
FAZ-B50/3
FAZ-B63/3
Article no.
FAZ-C10/3
FAZ-C12/3
FAZ-C13/3
FAZ-C15/3
FAZ-C16/3
FAZ-C20/3
FAZ-C25/3
FAZ-C32/3
FAZ-C40/3
FAZ-C50/3
FAZ-C63/3
FAZ-C0,16/3
FAZ-C0,25/3
FAZ-C0,5/3
FAZ-C0,75/3
FAZ-C1/3
FAZ-C1,5/3
FAZ-C1,6/3
FAZ-C2/3
FAZ-C2,5/3
FAZ-C3/3
FAZ-C3,5/3
FAZ-C4/3
FAZ-C5/3
FAZ-C6/3
FAZ-C8/3
278866
278867
278868
278869
278870
278871
278872
278873
278874
278875
278876
278877
278878
278879
278854
278855
278856
278857
278858
278859
278860
278861
278862
278863
278864
278865
278843
278844
278845
278846
278847
278848
278849
278850
278851
278852
278853
278832
278833
278834
278835
278836
278837
278838
278839
278840
278841
278842
CA08103003Z_MOEM2015-EN.book Seite 254 Donnerstag, 7. April 2016 12:02 12
Circuit-breaker
FAZ miniature circuit-breakers
Rated current Switching capacity
(IEC/EN 60947-2)
I n
A kA
FAZ miniature circuit-breakers
16
20
25
8
10
12
13
15
32
40
50
63
4
5
6
2.5
3
3.5
1
1.5
1.6
2
(please enquire for circuit-breakers with 3+N and 4 poles)
Characteristic D
Instantaneous release response current
10 - 20 x In
0.5
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
10
10
13
16
20
6
8
10
25
32
40
50
63
1.6
2
3
4
Characteristic K
Instantaneous release response current
8 - 12 x In
0.5
1
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
1 pole
Part no.
FAZ-D0,5/1
FAZ-D1/1
FAZ-D1,5/1
FAZ-D1,6/1
FAZ-D2/1
FAZ-D2,5/1
FAZ-D3/1
FAZ-D3,5/1
FAZ-D4/1
FAZ-D5/1
FAZ-D6/1
FAZ-D8/1
FAZ-D10/1
FAZ-D12/1
FAZ-D13/1
FAZ-D15/1
FAZ-D16/1
FAZ-D20/1
FAZ-D25/1
FAZ-D32/1
FAZ-D40/1
FAZ-D50/1
FAZ-D63/1
FAZ-K0,5/1
FAZ-K1/1
FAZ-K1,6/1
FAZ-K2/1
FAZ-K3/1
FAZ-K4/1
FAZ-K6/1
FAZ-K8/1
FAZ-K10/1
FAZ-K13/1
FAZ-K16/1
FAZ-K20/1
FAZ-K25/1
FAZ-K32/1
FAZ-K40/1
FAZ-K50/1
FAZ-K63/1
1 pole+N
Article no.
Part no.
278589
278590
278591
278592
278593
278594
278595
278596
278597
278598
278599
278600
278601
278602
278603
278604
278605
278579
278580
278581
278582
278583
278584
278585
278586
278587
278588
115370
115371
278568
278569
278570
278571
278572
278573
278574
278575
278576
278577
278578
2 pole
Article no.
Part no.
FAZ-D0,5/1N 278681
FAZ-D1/1N 278682
FAZ-D1,5/1N 278683
FAZ-D1,6/1N 278684
FAZ-D2/1N 278685
FAZ-D2,5/1N 278686
FAZ-D3/1N 278687
FAZ-D3,5/1N 278688
FAZ-D4/1N
FAZ-D5/1N
278689
278690
FAZ-D6/1N
FAZ-D8/1N
FAZ-D10/1N
278691
278692
278693
FAZ-D12/1N
FAZ-D13/1N
FAZ-D15/1N
FAZ-D16/1N
FAZ-D20/1N
FAZ-D25/1N
278694
278695
278696
278697
278698
278699
FAZ-D32/1N
FAZ-D40/1N
FAZ-D50/1N
FAZ-D63/1N
278700
278701
115378
115379
FAZ-K0,5/1N 278702
FAZ-K1/1N 278703
FAZ-K1,6/1N 278704
FAZ-K2/1N
FAZ-K3/1N
278705
278706
FAZ-K4/1N
FAZ-K6/1N
FAZ-K8/1N
FAZ-K10/1N
278707
278708
278709
278710
FAZ-K13/1N
FAZ-K16/1N
FAZ-K20/1N
FAZ-K25/1N
FAZ-K32/1N
FAZ-K40/1N
FAZ-K50/1N
FAZ-K63/1N
278711
278712
278713
278714
278715
278716
278717
278718
3 pole
Article no.
Part no.
FAZ-D0,5/2 278767
FAZ-D1/2 278768
FAZ-D1,5/2 278769
FAZ-D1,6/2 278770
FAZ-D2/2 278771
FAZ-D2,5/2 278772
FAZ-D3/2 278773
FAZ-D3,5/2 278774
FAZ-D4/2
FAZ-D5/2
278775
278776
FAZ-D6/2
FAZ-D8/2
FAZ-D10/2
278777
278778
278779
FAZ-D12/2
FAZ-D13/2
FAZ-D15/2
FAZ-D16/2
FAZ-D20/2
FAZ-D25/2
278780
278781
278782
278783
278784
278785
FAZ-D32/2
FAZ-D40/2
FAZ-D50/2
FAZ-D63/2
278786
278787
115372
115373
FAZ-K0,5/2 278788
FAZ-K1/2 278789
FAZ-K1,6/2 278790
FAZ-K2/2
FAZ-K3/2
278791
278792
FAZ-K4/2
FAZ-K6/2
FAZ-K8/2
FAZ-K10/2
278793
278794
278795
278796
FAZ-K13/2
FAZ-K16/2
FAZ-K20/2
FAZ-K25/2
FAZ-K32/2
FAZ-K40/2
FAZ-K50/2
FAZ-K63/2
278797
278798
278799
278800
278801
278802
278803
278804
Article no.
FAZ-D0,5/3
FAZ-D1/3
FAZ-D1,5/3
FAZ-D1,6/3
FAZ-D2/3
FAZ-D2,5/3
FAZ-D3/3
FAZ-D3,5/3
FAZ-D4/3
FAZ-D5/3
FAZ-D6/3
FAZ-D8/3
FAZ-D10/3
FAZ-D12/3
FAZ-D13/3
FAZ-D15/3
FAZ-D16/3
FAZ-D20/3
FAZ-D25/3
FAZ-D32/3
FAZ-D40/3
FAZ-D50/3
FAZ-D63/3
278891
278892
278893
278894
278895
278896
278897
278898
278899
278900
115374
115375
278880
278881
278882
278883
278884
278885
278886
278887
278888
278889
278890
FAZ-K0,5/3
FAZ-K1/3
FAZ-K1,6/3
FAZ-K2/3
FAZ-K3/3
FAZ-K4/3
FAZ-K6/3
FAZ-K8/3
FAZ-K10/3
FAZ-K13/3
FAZ-K16/3
FAZ-K20/3
FAZ-K25/3
FAZ-K32/3
FAZ-K40/3
FAZ-K50/3
FAZ-K63/3
278901
278902
278903
278904
278905
278906
278907
278908
278909
278910
278911
278912
278913
278914
278915
278916
278917
EATON CA08103003Z-EN-INT
Moeller® series
Complete assortment -> www.eaton.eu/ecat
CA08103003Z-en-EN_253-255__FAZ_GG_A4_g.fm Seite 255 Mittwoch, 13. April 2016 8:59 08
Moeller® series
FAZ, FAZ-DC miniature circuit-breaker
Circuit-breaker
FAZ, FAZ-DC miniature circuit-breaker
Rated current Switching capacity
(IEC/EN 60947-2)
I n
A kA
FAZ miniature circuit-breakers
Characteristic S
Instantaneous release response current
13 - 17 x In
1 10
8
10
16
20
4
6
2
3
25
32
40
50
10
16
20
25
4
6
2
3
10
10
10
10
10
10
10
10
0.5
1
1.6
32
40
10
10
Characteristic Z
Instantaneous release response current
2 - 3 x In
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
63 15
FAZ miniature circuit-breakers for DC applications
25
32
40
50
10
13
16
20
4
6
2
3
Characteristic C
Instantaneous release response current
5 - 10 x In
10
10
10
10
10
10
10
10
10
10
10
10
1 pole
Part no.
FAZ-S1/1
FAZ-S2/1
FAZ-S3/1
FAZ-S4/1
FAZ-S6/1
FAZ-S10/1
FAZ-S16/1
FAZ-S20/1
FAZ-S25/1
FAZ-S32/1
FAZ-S40/1
FAZ-Z0,5/1
FAZ-Z1/1
FAZ-Z1,6/1
FAZ-Z2/1
FAZ-Z3/1
FAZ-Z4/1
FAZ-Z6/1
FAZ-Z8/1
FAZ-Z10/1
FAZ-Z16/1
FAZ-Z20/1
FAZ-Z25/1
FAZ-Z32/1
FAZ-Z40/1
FAZ-Z50/1
FAZ-Z63/1
FAZ-C2/1-DC
FAZ-C3/1-DC
FAZ-C4/1-DC
FAZ-C6/1-DC
FAZ-C10/1-DC
FAZ-C13/1-DC
FAZ-C16/1-DC
FAZ-C20/1-DC
FAZ-C25/1-DC
FAZ-C32/1-DC
FAZ-C40/1-DC
FAZ-C50/1-DC
Article no.
2 pole
Part no.
278606
278607
278608
278609
278610
278611
278612
278613
278614
278615
278616
278624
278625
278626
278627
278628
278629
278630
278631
278632
278617
278618
278619
278620
278621
278622
278623
279122
279123
279124
279125
279126
279127
279128
279129
279130
279131
279132
279133
FAZ-S1/2
FAZ-S2/2
FAZ-S3/2
FAZ-S4/2
FAZ-S6/2
FAZ-S10/2
FAZ-S16/2
FAZ-S20/2
FAZ-S25/2
FAZ-S32/2
FAZ-S40/2
FAZ-Z0,5/2
FAZ-Z1/2
FAZ-Z1,6/2
FAZ-Z2/2
FAZ-Z3/2
FAZ-Z4/2
FAZ-Z6/2
FAZ-Z8/2
FAZ-Z10/2
FAZ-Z16/2
FAZ-Z20/2
FAZ-Z25/2
FAZ-Z32/2
FAZ-Z40/2
FAZ-Z50/2
FAZ-Z63/2
FAZ-C2/2-DC
FAZ-C3/2-DC
FAZ-C4/2-DC
FAZ-C6/2-DC
FAZ-C10/2-DC
FAZ-C13/2-DC
FAZ-C16/2-DC
FAZ-C20/2-DC
FAZ-C25/2-DC
FAZ-C32/2-DC
FAZ-C40/2-DC
FAZ-C50/2-DC
Article no.
3 pole
Part no.
278805
278806
278807
278808
278809
278810
278811
278812
278813
278814
278815
278823
278824
278825
278826
278827
278828
278829
278830
278831
278816
278817
278818
278819
278820
278821
278822
279134
279135
279136
279137
279138
279139
279140
279141
279142
279143
279144
279145
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FAZ-Z0,5/3
FAZ-Z1/3
FAZ-Z1,6/3
FAZ-Z2/3
FAZ-Z3/3
FAZ-Z4/3
FAZ-Z6/3
FAZ-Z8/3
FAZ-Z10/3
FAZ-Z16/3
FAZ-Z20/3
FAZ-Z25/3
FAZ-Z32/3
FAZ-Z40/3
FAZ-Z50/3
FAZ-Z63/3
-
-
-
-
-
-
-
-
-
-
-
-
Article no.
278925
278926
278927
278928
278929
278930
278931
278932
278933
278918
278919
278920
278921
278922
278923
278924
-
-
-
-
-
-
-
-
-
-
-
EATON CORPORATION CA08103003Z-EN 255
CA08103003Z-en-EN_253-255__FAZ_GG_A4_g.fm Seite 255 Mittwoch, 13. April 2016 8:59 08
Moeller® series
FAZ, FAZ-DC miniature circuit-breaker
Circuit-breaker
FAZ, FAZ-DC miniature circuit-breaker
Rated current Switching capacity
(IEC/EN 60947-2)
I n
A kA
FAZ miniature circuit-breakers
Characteristic S
Instantaneous release response current
13 - 17 x In
1 10
8
10
16
20
4
6
2
3
25
32
40
50
10
16
20
25
4
6
2
3
10
10
10
10
10
10
10
10
0.5
1
1.6
32
40
10
10
Characteristic Z
Instantaneous release response current
2 - 3 x In
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
63 15
FAZ miniature circuit-breakers for DC applications
25
32
40
50
10
13
16
20
4
6
2
3
Characteristic C
Instantaneous release response current
5 - 10 x In
10
10
10
10
10
10
10
10
10
10
10
10
1 pole
Part no.
FAZ-S1/1
FAZ-S2/1
FAZ-S3/1
FAZ-S4/1
FAZ-S6/1
FAZ-S10/1
FAZ-S16/1
FAZ-S20/1
FAZ-S25/1
FAZ-S32/1
FAZ-S40/1
FAZ-Z0,5/1
FAZ-Z1/1
FAZ-Z1,6/1
FAZ-Z2/1
FAZ-Z3/1
FAZ-Z4/1
FAZ-Z6/1
FAZ-Z8/1
FAZ-Z10/1
FAZ-Z16/1
FAZ-Z20/1
FAZ-Z25/1
FAZ-Z32/1
FAZ-Z40/1
FAZ-Z50/1
FAZ-Z63/1
FAZ-C2/1-DC
FAZ-C3/1-DC
FAZ-C4/1-DC
FAZ-C6/1-DC
FAZ-C10/1-DC
FAZ-C13/1-DC
FAZ-C16/1-DC
FAZ-C20/1-DC
FAZ-C25/1-DC
FAZ-C32/1-DC
FAZ-C40/1-DC
FAZ-C50/1-DC
Article no.
2 pole
Part no.
278606
278607
278608
278609
278610
278611
278612
278613
278614
278615
278616
278624
278625
278626
278627
278628
278629
278630
278631
278632
278617
278618
278619
278620
278621
278622
278623
279122
279123
279124
279125
279126
279127
279128
279129
279130
279131
279132
279133
FAZ-S1/2
FAZ-S2/2
FAZ-S3/2
FAZ-S4/2
FAZ-S6/2
FAZ-S10/2
FAZ-S16/2
FAZ-S20/2
FAZ-S25/2
FAZ-S32/2
FAZ-S40/2
FAZ-Z0,5/2
FAZ-Z1/2
FAZ-Z1,6/2
FAZ-Z2/2
FAZ-Z3/2
FAZ-Z4/2
FAZ-Z6/2
FAZ-Z8/2
FAZ-Z10/2
FAZ-Z16/2
FAZ-Z20/2
FAZ-Z25/2
FAZ-Z32/2
FAZ-Z40/2
FAZ-Z50/2
FAZ-Z63/2
FAZ-C2/2-DC
FAZ-C3/2-DC
FAZ-C4/2-DC
FAZ-C6/2-DC
FAZ-C10/2-DC
FAZ-C13/2-DC
FAZ-C16/2-DC
FAZ-C20/2-DC
FAZ-C25/2-DC
FAZ-C32/2-DC
FAZ-C40/2-DC
FAZ-C50/2-DC
Article no.
3 pole
Part no.
278805
278806
278807
278808
278809
278810
278811
278812
278813
278814
278815
278823
278824
278825
278826
278827
278828
278829
278830
278831
278816
278817
278818
278819
278820
278821
278822
279134
279135
279136
279137
279138
279139
279140
279141
279142
279143
279144
279145
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FAZ-Z0,5/3
FAZ-Z1/3
FAZ-Z1,6/3
FAZ-Z2/3
FAZ-Z3/3
FAZ-Z4/3
FAZ-Z6/3
FAZ-Z8/3
FAZ-Z10/3
FAZ-Z16/3
FAZ-Z20/3
FAZ-Z25/3
FAZ-Z32/3
FAZ-Z40/3
FAZ-Z50/3
FAZ-Z63/3
-
-
-
-
-
-
-
-
-
-
-
-
Article no.
278925
278926
278927
278928
278929
278930
278931
278932
278933
278918
278919
278920
278921
278922
278923
278924
-
-
-
-
-
-
-
-
-
-
-
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 256 Donnerstag, 7. April 2016 12:02 12
Circuit-breaker
FAZ-T miniature circuit-breaker
FAZ-T miniature circuit-breaker
Moeller® series
CA08103003Z_MOEM2015-EN.book Seite 257 Donnerstag, 7. April 2016 12:02 12
Moeller® series
FAZ-NA miniature circuit-breakers for North America
Rated current Switching capacity
(IEC/EN 60947-2)
I n
A kA
FAZ-T miniature circuit-breaker
16
20
25
32
40
6
10
12
13
15
2
3
4
3
4
6
10
(please enquire for circuit-breakers with 3+N and 4 poles)
Characteristic B
Response current of short-circuit release
3-5 x In
1 25
2 25
25
25
25
25
20
25
32
40
12
13
15
16
25
25
25
25
25
25
20
20
Characteristic C
Response current of short-circuit release
5-10 x In
1 25
10
12
13
15
4
6
2
3
25
25
25
25
25
25
25
25
16
20
25
32
25
25
25
20
40 20
Characteristic D
Response current of short-circuit release
10-20 x In
1 25
20
20
15
15
15
25
25
25
25
20
25
25
25
1 pole
Part no.
FAZT-B1/1
FAZT-B2/1
FAZT-B3/1
FAZT-B4/1
FAZT-B6/1
FAZT-B10/1
FAZT-B12/1
FAZT-B13/1
FAZT-B15/1
FAZT-B16/1
FAZT-B20/1
FAZT-B25/1
FAZT-B32/1
FAZT-B40/1
FAZT-C1/1
FAZT-C2/1
FAZT-C3/1
FAZT-C4/1
FAZT-C6/1
FAZT-C10/1
FAZT-C12/1
FAZT-C13/1
FAZT-C15/1
FAZT-C16/1
FAZT-C20/1
FAZT-C25/1
FAZT-C32/1
FAZT-C40/1
FAZT-D1/1
FAZT-D2/1
FAZT-D3/1
FAZT-D4/1
FAZT-D6/1
FAZT-D10/1
FAZT-D12/1
FAZT-D13/1
FAZT-D15/1
FAZT-D16/1
FAZT-D20/1
FAZT-D25/1
FAZT-D32/1
FAZT-D40/1
1 pole+N
Article no.
Part no.
240798
240799
240800
240801
240802
240803
240804
240805
240806
240807
240808
240809
141909
142480
240792
240793
240794
240795
240796
240797
141907
141908
240770
240771
240772
240777
240782
240787
240810
240811
240812
240813
240814
240815
240816
240817
240818
240819
142481
142482
142483
142484
2 pole
Article no.
Part no.
FAZT-B1/1N
FAZT-B2/1N
240994
240995
FAZT-B3/1N
FAZT-B4/1N
240996
240997
FAZT-B6/1N 240998
FAZT-B10/1N 240999
FAZT-B12/1N 241000
FAZT-B13/1N 241001
FAZT-B15/1N 241005
FAZT-B16/1N 241009
FAZT-B20/1N 241015
FAZT-B25/1N 241019
FAZT-B32/1N 142509
FAZT-B40/1N 142510
FAZT-C1/1N
FAZT-C2/1N
FAZT-C3/1N
FAZT-C4/1N
FAZT-C6/1N
241022
241023
241024
241025
241026
FAZT-C10/1N 241027
FAZT-C12/1N 241028
FAZT-C13/1N 241029
FAZT-C15/1N 241030
FAZT-C16/1N 241034
FAZT-C20/1N 241038
FAZT-C25/1N 241044
FAZT-C32/1N 142511
FAZT-C40/1N 142512
FAZT-D1/1N
FAZT-D2/1N
FAZT-D3/1N
FAZT-D4/1N
241048
241051
241052
241053
FAZT-D6/1N 241054
FAZT-D10/1N 241055
FAZT-D12/1N 241056
FAZT-D13/1N 241057
FAZT-D15/1N 241058
FAZT-D16/1N 241059
FAZT-D20/1N 142513
FAZT-D25/1N 142514
FAZT-D32/1N 142515
FAZT-D40/1N 142516
EATON CA08103003Z-EN-INT
FAZT-B1/2
FAZT-B2/2
FAZT-B3/2
FAZT-B4/2
FAZT-B6/2
FAZT-B10/2
FAZT-B12/2
FAZT-B13/2
FAZT-B15/2
FAZT-B16/2
FAZT-B20/2
FAZT-B25/2
FAZT-B32/2
FAZT-B40/2
FAZT-C1/2
FAZT-C2/2
FAZT-C3/2
FAZT-C4/2
FAZT-C6/2
FAZT-C10/2
FAZT-C12/2
FAZT-C13/2
FAZT-C15/2
FAZT-C16/2
FAZT-C20/2
FAZT-C25/2
FAZT-C32/2
FAZT-C40/2
FAZT-D1/2
FAZT-D2/2
FAZT-D3/2
FAZT-D4/2
FAZT-D6/2
FAZT-D10/2
FAZT-D12/2
FAZT-D13/2
FAZT-D15/2
FAZT-D16/2
FAZT-D20/2
FAZT-D25/2
FAZT-D32/2
FAZT-D40/2
3 pole
Article no.
Part no.
240864
240865
240866
240867
240868
240869
240870
240871
240872
240873
142489
142490
142491
142492
240832
240833
240838
240843
240850
240855
240858
240859
240860
240861
240862
240863
142487
142488
240826
240827
240828
240829
240830
240831
142485
142486
240820
240821
240822
240823
240824
240825
FAZT-D1/3
FAZT-D2/3
FAZT-D3/3
FAZT-D4/3
FAZT-D6/3
FAZT-D10/3
FAZT-D12/3
FAZT-D13/3
FAZT-D15/3
FAZT-D16/3
FAZT-D20/3
FAZT-D25/3
FAZT-D32/3
FAZT-D40/3
FAZT-C1/3
FAZT-C2/3
FAZT-C3/3
FAZT-C4/3
FAZT-C6/3
FAZT-C10/3
FAZT-C12/3
FAZT-C13/3
FAZT-C15/3
FAZT-C16/3
FAZT-C20/3
FAZT-C25/3
FAZT-C32/3
FAZT-C40/3
FAZT-B1/3
FAZT-B2/3
FAZT-B3/3
FAZT-B4/3
FAZT-B6/3
FAZT-B10/3
FAZT-B12/3
FAZT-B13/3
FAZT-B15/3
FAZT-B16/3
FAZT-B20/3
FAZT-B25/3
FAZT-B32/3
FAZT-B40/3
Article no.
240898
240899
240900
240901
240902
240903
240904
240905
240910
240915
142497
142498
142499
142500
240886
240887
240888
240889
240890
240891
240892
240893
240894
240895
240896
240897
142495
142496
240880
240881
240882
240883
240884
240885
142493
142494
240874
240875
240876
240877
240878
240879
Complete assortment -> www.eaton.eu/ecat EATON CORPORATION CA08103003Z-EN
Circuit-breaker
FAZ-NA miniature circuit-breakers for North America
Rated current Switching capacity
(IEC/EN 60947-2)
I n
A kA
Miniature circuit-breakers FAZ for North
America
Characteristic B
Response current of short-circuit release
3-5 x In
1 10
1.5
10
30
32
35
40
15
16
20
25
7
8
10
13
5
6
3
4
25
30
32
13
15
16
20
7
8
5
6
10
2
3
4
10
10
10
10
10
10
10
10
10
14
14
14
14
10
10
0.5
1
1.5
2
35
40
10
10
Characteristic C
Response current of short-circuit release
5-10 x In
10
10
10
10
10
10
10
10
14
14
14
14
10
10
10
10
10
10
10
10
1 pole
Part no.
FAZ-B1/1-NA
FAZ-B1,5/1-NA
FAZ-B2/1-NA
FAZ-B3/1-NA
FAZ-B4/1-NA
FAZ-B5/1-NA
FAZ-B6/1-NA
FAZ-B7/1-NA
FAZ-B8/1-NA
FAZ-B10/1-NA
FAZ-B13/1-NA
FAZ-B15/1-NA
FAZ-B16/1-NA
FAZ-B20/1-NA
FAZ-B25/1-NA
FAZ-B30/1-NA
FAZ-B32/1-NA
FAZ-B35/1-NA
FAZ-B40/1-NA
FAZ-C0,5/1-NA
FAZ-C1/1-NA
FAZ-C1,5/1-NA
FAZ-C2/1-NA
FAZ-C3/1-NA
FAZ-C4/1-NA
FAZ-C5/1-NA
FAZ-C6/1-NA
FAZ-C7/1-NA
FAZ-C8/1-NA
FAZ-C10/1-NA
FAZ-C13/1-NA
FAZ-C15/1-NA
FAZ-C16/1-NA
FAZ-C20/1-NA
FAZ-C25/1-NA
FAZ-C30/1-NA
FAZ-C32/1-NA
FAZ-C35/1-NA
FAZ-C40/1-NA
Article no.
2 pole
Part no.
102085
102086
102087
102088
102089
102090
102091
102092
102077
102078
102079
102080
102081
102082
102083
102084
102093
102094
102095
102096
132414
132415
132416
132417
132418
132419
132680
132681
132682
132683
132684
132685
132686
132687
132688
132689
132690
132691
132692
FAZ-C0,5/2-NA
FAZ-C1/2-NA
FAZ-C1,5/2-NA
FAZ-C2/2-NA
FAZ-C3/2-NA
FAZ-C4/2-NA
FAZ-C5/2-NA
FAZ-C6/2-NA
FAZ-C7/2-NA
FAZ-C8/2-NA
FAZ-C10/2-NA
FAZ-C13/2-NA
FAZ-C15/2-NA
FAZ-C16/2-NA
FAZ-C20/2-NA
FAZ-C25/2-NA
FAZ-C30/2-NA
FAZ-C32/2-NA
FAZ-C35/2-NA
FAZ-C40/2-NA
Article no.
3 pole
Part no.
FAZ-B1/2-NA
FAZ-B1,5/2-NA
FAZ-B2/2-NA
FAZ-B3/2-NA
FAZ-B4/2-NA
FAZ-B5/2-NA
FAZ-B6/2-NA
FAZ-B7/2-NA
FAZ-B8/2-NA
FAZ-B10/2-NA
FAZ-B13/2-NA
FAZ-B15/2-NA
FAZ-B16/2-NA
FAZ-B20/2-NA
FAZ-B25/2-NA
FAZ-B30/2-NA
FAZ-B32/2-NA
FAZ-B35/2-NA
FAZ-B40/2-NA
132693
132694
132695
132696
132697
132698
132699
132700
132701
132702
132703
132704
132705
132706
132707
132708
132709
132710
132711
102165
102166
102167
102168
102169
102170
102171
102172
102157
102158
102159
102160
102161
102162
102163
102164
102173
102174
102175
102176
FAZ-C0,5/3-NA
FAZ-C1/3-NA
FAZ-C1,5/3-NA
FAZ-C2/3-NA
FAZ-C3/3-NA
FAZ-C4/3-NA
FAZ-C5/3-NA
FAZ-C6/3-NA
FAZ-C7/3-NA
FAZ-C8/3-NA
FAZ-C10/3-NA
FAZ-C13/3-NA
FAZ-C15/3-NA
FAZ-C16/3-NA
FAZ-C20/3-NA
FAZ-C25/3-NA
FAZ-C30/3-NA
FAZ-C32/3-NA
FAZ-C35/3-NA
FAZ-C40/3-NA
Article no.
FAZ-B1/3-NA
FAZ-B1,5/3-NA
FAZ-B2/3-NA
FAZ-B3/3-NA
FAZ-B4/3-NA
FAZ-B5/3-NA
FAZ-B6/3-NA
FAZ-B7/3-NA
FAZ-B8/3-NA
FAZ-B10/3-NA
FAZ-B13/3-NA
FAZ-B15/3-NA
FAZ-B16/3-NA
FAZ-B20/3-NA
FAZ-B25/3-NA
FAZ-B30/3-NA
FAZ-B32/3-NA
FAZ-B35/3-NA
FAZ-B40/3-NA
132712
132713
132714
132715
132716
132717
132718
132719
132720
132721
132722
132723
132724
132725
132726
132727
132728
132729
132730
102245
102246
102247
102248
102249
102250
102251
102252
102237
102238
102239
102240
102241
102242
102243
102244
102253
102254
102255
102256
257
CA08103003Z_MOEM2015-EN.book Seite 257 Donnerstag, 7. April 2016 12:02 12
Moeller® series
FAZ-NA miniature circuit-breakers for North America
Circuit-breaker
FAZ-NA miniature circuit-breakers for North America
Rated current Switching capacity
(IEC/EN 60947-2)
I n
A kA
Miniature circuit-breakers FAZ for North
America
Characteristic B
Response current of short-circuit release
3-5 x In
1 10
1.5
10
30
32
35
40
15
16
20
25
7
8
10
13
5
6
3
4
25
30
32
13
15
16
20
7
8
5
6
10
2
3
4
10
10
10
10
10
10
10
10
10
14
14
14
14
10
10
0.5
1
1.5
2
35
40
10
10
Characteristic C
Response current of short-circuit release
5-10 x In
10
10
10
10
10
10
10
10
14
14
14
14
10
10
10
10
10
10
10
10
1 pole
Part no.
FAZ-B1/1-NA
FAZ-B1,5/1-NA
FAZ-B2/1-NA
FAZ-B3/1-NA
FAZ-B4/1-NA
FAZ-B5/1-NA
FAZ-B6/1-NA
FAZ-B7/1-NA
FAZ-B8/1-NA
FAZ-B10/1-NA
FAZ-B13/1-NA
FAZ-B15/1-NA
FAZ-B16/1-NA
FAZ-B20/1-NA
FAZ-B25/1-NA
FAZ-B30/1-NA
FAZ-B32/1-NA
FAZ-B35/1-NA
FAZ-B40/1-NA
FAZ-C0,5/1-NA
FAZ-C1/1-NA
FAZ-C1,5/1-NA
FAZ-C2/1-NA
FAZ-C3/1-NA
FAZ-C4/1-NA
FAZ-C5/1-NA
FAZ-C6/1-NA
FAZ-C7/1-NA
FAZ-C8/1-NA
FAZ-C10/1-NA
FAZ-C13/1-NA
FAZ-C15/1-NA
FAZ-C16/1-NA
FAZ-C20/1-NA
FAZ-C25/1-NA
FAZ-C30/1-NA
FAZ-C32/1-NA
FAZ-C35/1-NA
FAZ-C40/1-NA
Article no.
2 pole
Part no.
102085
102086
102087
102088
102089
102090
102091
102092
102077
102078
102079
102080
102081
102082
102083
102084
102093
102094
102095
102096
132414
132415
132416
132417
132418
132419
132680
132681
132682
132683
132684
132685
132686
132687
132688
132689
132690
132691
132692
FAZ-C0,5/2-NA
FAZ-C1/2-NA
FAZ-C1,5/2-NA
FAZ-C2/2-NA
FAZ-C3/2-NA
FAZ-C4/2-NA
FAZ-C5/2-NA
FAZ-C6/2-NA
FAZ-C7/2-NA
FAZ-C8/2-NA
FAZ-C10/2-NA
FAZ-C13/2-NA
FAZ-C15/2-NA
FAZ-C16/2-NA
FAZ-C20/2-NA
FAZ-C25/2-NA
FAZ-C30/2-NA
FAZ-C32/2-NA
FAZ-C35/2-NA
FAZ-C40/2-NA
Article no.
3 pole
Part no.
FAZ-B1/2-NA
FAZ-B1,5/2-NA
FAZ-B2/2-NA
FAZ-B3/2-NA
FAZ-B4/2-NA
FAZ-B5/2-NA
FAZ-B6/2-NA
FAZ-B7/2-NA
FAZ-B8/2-NA
FAZ-B10/2-NA
FAZ-B13/2-NA
FAZ-B15/2-NA
FAZ-B16/2-NA
FAZ-B20/2-NA
FAZ-B25/2-NA
FAZ-B30/2-NA
FAZ-B32/2-NA
FAZ-B35/2-NA
FAZ-B40/2-NA
132693
132694
132695
132696
132697
132698
132699
132700
132701
132702
132703
132704
132705
132706
132707
132708
132709
132710
132711
102165
102166
102167
102168
102169
102170
102171
102172
102157
102158
102159
102160
102161
102162
102163
102164
102173
102174
102175
102176
FAZ-C0,5/3-NA
FAZ-C1/3-NA
FAZ-C1,5/3-NA
FAZ-C2/3-NA
FAZ-C3/3-NA
FAZ-C4/3-NA
FAZ-C5/3-NA
FAZ-C6/3-NA
FAZ-C7/3-NA
FAZ-C8/3-NA
FAZ-C10/3-NA
FAZ-C13/3-NA
FAZ-C15/3-NA
FAZ-C16/3-NA
FAZ-C20/3-NA
FAZ-C25/3-NA
FAZ-C30/3-NA
FAZ-C32/3-NA
FAZ-C35/3-NA
FAZ-C40/3-NA
Article no.
FAZ-B1/3-NA
FAZ-B1,5/3-NA
FAZ-B2/3-NA
FAZ-B3/3-NA
FAZ-B4/3-NA
FAZ-B5/3-NA
FAZ-B6/3-NA
FAZ-B7/3-NA
FAZ-B8/3-NA
FAZ-B10/3-NA
FAZ-B13/3-NA
FAZ-B15/3-NA
FAZ-B16/3-NA
FAZ-B20/3-NA
FAZ-B25/3-NA
FAZ-B30/3-NA
FAZ-B32/3-NA
FAZ-B35/3-NA
FAZ-B40/3-NA
132712
132713
132714
132715
132716
132717
132718
132719
132720
132721
132722
132723
132724
132725
132726
132727
132728
132729
132730
102245
102246
102247
102248
102249
102250
102251
102252
102237
102238
102239
102240
102241
102242
102243
102244
102253
102254
102255
102256
Complete assortment -> www.eaton.eu/ecat EATON CA08103003Z-EN-INT
CA08103003Z_MOEM2015-EN.book Seite 258 Donnerstag, 7. April 2016 12:02 12
Circuit-breaker
FAZ-NA, FAZ-NA-DC miniature circuit-breakers for North America
FAZ-NA, FAZ-NA-DC miniature circuit-breakers for North America
Rated current Switching capacity
(IEC/EN 60947-2)
I n
A kA
FAZ miniature circuit-breakers for North
America
25
30
32
35
40
10
13
15
16
20
6
7
8
4
5
2
3
Characteristic D
Response current of short-circuit release
10-20 x In
0.5
1
1.5
10
10
10
10
10
10
10
10
10
10
10
10
14
14
14
14
10
10
10
10
Miniature circuit-breaker for North
America for DC applications
20
25
30
32
10
13
15
16
35
40
7
8
5
6
2
3
Characteristic C
Response current of short-circuit release
5-10 x In
4
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
1 pole
Part no.
FAZ-C2/1-NA-DC
FAZ-C3/1-NA-DC
FAZ-C4/1-NA-DC
FAZ-C5/1-NA-DC
FAZ-C6/1-NA-DC
FAZ-C7/1-NA-DC
FAZ-C8/1-NA-DC
FAZ-C10/1-NA-DC
FAZ-C13/1-NA-DC
FAZ-C15/1-NA-DC
FAZ-C16/1-NA-DC
FAZ-C20/1-NA-DC
FAZ-C25/1-NA-DC
FAZ-C30/1-NA-DC
FAZ-C32/1-NA-DC
FAZ-C35/1-NA-DC
FAZ-C40/1-NA-DC
FAZ-D0,5/1-NA
FAZ-D1/1-NA
FAZ-D1,5/1-NA
FAZ-D2/1-NA
FAZ-D3/1-NA
FAZ-D4/1-NA
FAZ-D5/1-NA
FAZ-D6/1-NA
FAZ-D7/1-NA
FAZ-D8/1-NA
FAZ-D10/1-NA
FAZ-D13/1-NA
FAZ-D15/1-NA
FAZ-D16/1-NA
FAZ-D20/1-NA
FAZ-D25/1-NA
FAZ-D30/1-NA
FAZ-D32/1-NA
FAZ-D35/1-NA
FAZ-D40/1-NA
Article no.
113759
113760
113761
113762
113763
113764
113765
113766
113767
113768
113752
113753
113754
113755
113756
113757
113758
102104
102105
102106
102107
102108
102109
102110
102111
102097
102098
102099
102100
102101
102102
102103
102112
102113
102114
102115
102116
2 pole
Part no.
FAZ-D0,5/2-NA
FAZ-D1/2-NA
FAZ-D1,5/2-NA
FAZ-D2/2-NA
FAZ-D3/2-NA
FAZ-D4/2-NA
FAZ-D5/2-NA
FAZ-D6/2-NA
FAZ-D7/2-NA
FAZ-D8/2-NA
FAZ-D10/2-NA
FAZ-D13/2-NA
FAZ-D15/2-NA
FAZ-D16/2-NA
FAZ-D20/2-NA
FAZ-D25/2-NA
FAZ-D30/2-NA
FAZ-D32/2-NA
FAZ-D35/2-NA
FAZ-D40/2-NA
Article no.
3 pole
Part no.
FAZ-C2/2-NA-DC
FAZ-C3/2-NA-DC
FAZ-C4/2-NA-DC
FAZ-C5/2-NA-DC
FAZ-C6/2-NA-DC
FAZ-C7/2-NA-DC
FAZ-C8/2-NA-DC
FAZ-C10/2-NA-DC
FAZ-C13/2-NA-DC
FAZ-C15/2-NA-DC
FAZ-C16/2-NA-DC
FAZ-C20/2-NA-DC
FAZ-C25/2-NA-DC
FAZ-C30/2-NA-DC
FAZ-C32/2-NA-DC
FAZ-C35/2-NA-DC
FAZ-C40/2-NA-DC
120641
120642
120643
120644
120645
120646
120647
120648
120649
120650
137239
137250
137251
137252
120638
120639
120640
102184
102185
102186
102187
102188
102189
102190
102191
102177
102178
102179
102180
102181
102182
102183
102192
102193
102194
102195
102196
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FAZ-D0,5/3-NA
FAZ-D1/3-NA
FAZ-D1,5/3-NA
FAZ-D2/3-NA
FAZ-D3/3-NA
FAZ-D4/3-NA
FAZ-D5/3-NA
FAZ-D6/3-NA
FAZ-D7/3-NA
FAZ-D8/3-NA
FAZ-D10/3-NA
FAZ-D13/3-NA
FAZ-D15/3-NA
FAZ-D16/3-NA
FAZ-D20/3-NA
FAZ-D25/3-NA
FAZ-D30/3-NA
FAZ-D32/3-NA
FAZ-D35/3-NA
FAZ-D40/3-NA
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Article no.
102264
102265
102266
102267
102268
102269
102270
102271
102257
102258
102259
102260
102261
102262
102263
102272
102273
102274
102275
102276
EATON CA08103003Z-EN-INT
Moeller® series
Complete assortment -> www.eaton.eu/ecat
CA08103003Z_MOEM2015-EN.book Seite 259 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Residual current circuit breakers FRC
Circuit-breaker
Residual current circuit breakers FRC
Rated current
I n
A
Rated fault current
I
Δ N
A
Part no.
Article no.
Residual current circuit breakers FRCdM, digital
(please enquire for 60-Hz products)
Type G, Short time-delayed
25 0.03
40
63
25
40
63
0.3
0.3
Type S, selective switch off
25 0.3
40
63
0.03
0.03
0.3
0.3
0.3
Residual current circuit breakers FRCmM-125
125 0.03
125
125
125
125
0.03
0.1
0.3
0.5
Type B, All current sensitive,
240/415 V
FRCDM-25/4/003-G/B
FRCDM-40/4/003-G/B
FRCDM-63/4/003-G/B
FRCDM-25/4/03-G/B
FRCDM-40/4/03-G/B
FRCDM-63/4/03-G/B
FRCDM-25/4/03-S/B
FRCDM-40/4/03-S/B
FRCDM-63/4/03-S/B
FRCMM-125/4/003-G/B
FRCMM-125/4/003-B
FRCMM-125/4/01-B
FRCMM-125/4/03-B
FRCMM-125/4/05-B
167892
167893
167894
167896
167897
167898
167900
167901
167902
171188
171184
171185
171186
171187
Type U, pulse-current sensitive, suitable for variable frequency drives, 240/415 V
FRCdM residual current circuit-breaker, digital
80
25
40
63
Type G, Short time-delayed
25 0.03
40
63
0.03
0.03
0.03
0.3
0.3
0.3
80
Type S, selective switch off
0.3
40
63
0.3
0.3
80 0.3
FRCmM Residual current circuit-breaker
Type G, Short time-delayed
16 0.03
40
63
80
100
40
63
16
25
25
40
63
80
100
Type S, selective switch off
0.03
16
25
0.1
0.1
0.03
0.03
0.03
0.03
0.3
0.3
0.3
0.3
0.1
0.1
0.3
0.3
-
FRCDM-40/4/003-U
-
-
-
-
-
FRCDM-63/4/003-U
FRCDM-40/4/03-U
FRCDM-63/4/03-U
FRCDM-80/4/03-U
FRCMM-16/4/003-U
FRCMM-25/4/003-U
FRCMM-40/4/003-U
FRCMM-63/4/003-U
FRCMM-80/4/003-U
FRCMM-100/4/003-U
FRCMM-16/4/01-U
FRCMM-25/4/01-U
FRCMM-40/4/01-U
FRCMM-63/4/01-U
FRCMM-16/4/03-U
FRCMM-25/4/03-U
FRCMM-40/4/03-U
FRCMM-63/4/03-U
FRCMM-80/4/03-U
FRCMM-100/4/03-U
-
-
-
-
-
-
168643
168640
168644
168641
168642
170452
170453
170454
170455
170456
170457
170458
170459
170460
170461
170462
170463
170464
170465
170466
170467
-
-
-
Part no.
Article no.
Type B+, All current sensitive,
240/415 V
FRCDM-25/4/003-G/B+
FRCDM-40/4/003-G/B+
FRCDM-63/4/003-G/B+
FRCDM-25/4/03-G/B+
FRCDM-40/4/03-G/B+
FRCDM-63/4/03-G/B+
FRCDM-25/4/03-S/B+
FRCDM-40/4/03-S/B+
FRCDM-63/4/03-S/B+
167880
167881
167882
167884
167885
167886
167888
167889
167890
-
-
-
-
FRCMM-125/4/003-G/B+ 171189
-
-
-
-
Type R, Radiography applications,
240/415 V
-
-
-
-
-
-
-
FRCDM-63/4/003-R
FRCMM-16/4/003-R
FRCMM-25/4/003-R
FRCMM-40/4/003-R
FRCMM-63/4/003-R
FRCMM-80/4/003-R
FRCMM-100/4/003-R
-
-
-
170308
170309
170310
170311
170312
170313
-
-
-
-
-
-
-
168636
-
-
-
-
-
-
Part no.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
EATON CORPORATION CA08103003Z-EN
-
-
-
-
-
-
-
-
-
-
FRCDM-25/4/03-S/BFQ
FRCDM-40/4/03-S/BFQ
FRCDM-63/4/03-S/BFQ
-
-
-
-
-
FRCMM-125/4/03-S/BFQ 171190
FRCMM-125/4/05-S/BFQ 171191
Type A, Pulse-current sensitive,
240/415 V
FRCDM-25/4/003-G/A
FRCDM-40/4/003-G/A
FRCDM-63/4/003-G/A
FRCDM-80/4/003-G/A
FRCDM-25/4/03-G/A
FRCDM-40/4/03-G/A
FRCDM-63/4/03-G/A
FRCDM-80/4/03-G/A
FRCDM-40/4/03-S/A
FRCDM-63/4/03-S/A
FRCDM-80/4/03-S/A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Article no.
Type Bfq, All current sensitive - frequency converter-proof, 240/415 V
FRCDM-25/4/003-G/BFQ 179530
FRCDM-40/4/003-G/BFQ 179531
FRCDM-63/4/003-G/BFQ 179532
FRCDM-25/4/03-G/BFQ 167904
FRCDM-40/4/03-G/BFQ
FRCDM-63/4/03-G/BFQ
167905
167906
167908
167909
167910
168646
168648
168650
168634
168647
168649
168651
168635
168637
168638
168639
259
CA08103003Z_MOEM2015-EN.book Seite 259 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Residual current circuit breakers FRC
Circuit-breaker
Residual current circuit breakers FRC
Rated current
I n
A
Rated fault current
I
Δ N
A
Part no.
Article no.
Residual current circuit breakers FRCdM, digital
(please enquire for 60-Hz products)
Type G, Short time-delayed
25 0.03
40
63
25
40
63
0.3
0.3
Type S, selective switch off
25 0.3
40
63
0.03
0.03
0.3
0.3
0.3
Residual current circuit breakers FRCmM-125
125 0.03
125
125
125
125
0.03
0.1
0.3
0.5
Type B, All current sensitive,
240/415 V
FRCDM-25/4/003-G/B
FRCDM-40/4/003-G/B
FRCDM-63/4/003-G/B
FRCDM-25/4/03-G/B
FRCDM-40/4/03-G/B
FRCDM-63/4/03-G/B
FRCDM-25/4/03-S/B
FRCDM-40/4/03-S/B
FRCDM-63/4/03-S/B
FRCMM-125/4/003-G/B
FRCMM-125/4/003-B
FRCMM-125/4/01-B
FRCMM-125/4/03-B
FRCMM-125/4/05-B
167892
167893
167894
167896
167897
167898
167900
167901
167902
171188
171184
171185
171186
171187
Type U, pulse-current sensitive, suitable for variable frequency drives, 240/415 V
FRCdM residual current circuit-breaker, digital
80
25
40
63
Type G, Short time-delayed
25 0.03
40
63
0.03
0.03
0.03
0.3
0.3
0.3
80
Type S, selective switch off
0.3
40
63
0.3
0.3
80 0.3
FRCmM Residual current circuit-breaker
Type G, Short time-delayed
16 0.03
40
63
80
100
40
63
16
25
25
40
63
80
100
Type S, selective switch off
0.03
16
25
0.1
0.1
0.03
0.03
0.03
0.03
0.3
0.3
0.3
0.3
0.1
0.1
0.3
0.3
-
FRCDM-40/4/003-U
-
-
-
-
-
FRCDM-63/4/003-U
FRCDM-40/4/03-U
FRCDM-63/4/03-U
FRCDM-80/4/03-U
FRCMM-16/4/003-U
FRCMM-25/4/003-U
FRCMM-40/4/003-U
FRCMM-63/4/003-U
FRCMM-80/4/003-U
FRCMM-100/4/003-U
FRCMM-16/4/01-U
FRCMM-25/4/01-U
FRCMM-40/4/01-U
FRCMM-63/4/01-U
FRCMM-16/4/03-U
FRCMM-25/4/03-U
FRCMM-40/4/03-U
FRCMM-63/4/03-U
FRCMM-80/4/03-U
FRCMM-100/4/03-U
-
-
-
-
-
-
168643
168640
168644
168641
168642
170452
170453
170454
170455
170456
170457
170458
170459
170460
170461
170462
170463
170464
170465
170466
170467
Complete assortment -> www.eaton.eu/ecat
-
-
-
Part no.
FRCDM-25/4/003-G/B+
FRCDM-40/4/003-G/B+
FRCDM-63/4/003-G/B+
FRCDM-25/4/03-G/B+
FRCDM-40/4/03-G/B+
FRCDM-63/4/03-G/B+
FRCDM-25/4/03-S/B+
FRCDM-40/4/03-S/B+
FRCDM-63/4/03-S/B+
-
-
-
-
FRCMM-125/4/003-G/B+ 171189
-
-
-
-
Type R, Radiography applications,
240/415 V
FRCMM-16/4/003-R
FRCMM-25/4/003-R
FRCMM-40/4/003-R
FRCMM-63/4/003-R
FRCMM-80/4/003-R
FRCMM-100/4/003-R
Article no.
Type B+, All current sensitive,
240/415 V
-
-
-
-
-
-
-
FRCDM-63/4/003-R
-
-
-
-
-
-
-
-
-
-
EATON CA08103003Z-EN-INT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
168636
170308
170309
170310
170311
170312
170313
167880
167881
167882
167884
167885
167886
167888
167889
167890
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Part no.
FRCDM-25/4/003-G/BFQ 179530
FRCDM-40/4/003-G/BFQ 179531
FRCDM-63/4/003-G/BFQ 179532
FRCDM-25/4/03-G/BFQ 167904
FRCDM-40/4/03-G/BFQ
FRCDM-63/4/03-G/BFQ
167905
167906
FRCDM-25/4/03-S/BFQ
FRCDM-40/4/03-S/BFQ
FRCDM-63/4/03-S/BFQ
167908
167909
167910
-
-
-
-
-
FRCMM-125/4/03-S/BFQ 171190
FRCMM-125/4/05-S/BFQ 171191
Type A, Pulse-current sensitive,
240/415 V
FRCDM-25/4/003-G/A
FRCDM-40/4/003-G/A
FRCDM-63/4/003-G/A
FRCDM-80/4/003-G/A
FRCDM-25/4/03-G/A
FRCDM-40/4/03-G/A
FRCDM-63/4/03-G/A
FRCDM-80/4/03-G/A
FRCDM-40/4/03-S/A
FRCDM-63/4/03-S/A
FRCDM-80/4/03-S/A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Article no.
Type Bfq, All current sensitive - frequency converter-proof, 240/415 V
168646
168648
168650
168634
168647
168649
168651
168635
168637
168638
168639
CA08103003Z_MOEM2015-EN.book Seite 260 Donnerstag, 7. April 2016 12:02 12
Circuit-breaker
Residual current circuit breakers FRC, FRC-NA
Residual current circuit breakers FRC, FRC-NA
Moeller® series
Rated current
I n
A
Rated fault current
I
Δ N
A
2 pole
240/415 V
Part no.
FRCmM Residual current circuit-breaker
16
25
40
80
100
125
25
40
63
(please enquire for products for other voltage ranges)
Type A, Pulse-current sensitive
16 0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.3
0.3
0.3
25
40
63
63
80
100
125
16
80
100
125
0.5
0.5
0.5
Type G/A (ÖVE E 8601), Short time-delayed
16 0.03
0.5
0.5
0.5
0.3
0.3
0.3
0.3
0.5
25
40
63
80
100
125
16
25
40
63
80
100
125
Type S/A, selective switch off
40
63
0.3
0.3
0.3
0.3
0.3
0.3
0.03
0.03
0.03
0.03
0.03
0.03
0.3
0.3
0.3
FRCMM-16/2/003-A
FRCMM-25/2/003-A
FRCMM-40/2/003-A
FRCMM-63/2/003-A
FRCMM-80/2/003-A
FRCMM-100/2/003-A
FRCMM-125/2/003-A
FRCMM-16/2/03-A
FRCMM-25/2/03-A
FRCMM-40/2/03-A
-
-
-
FRCMM-125/2/03-A
FRCMM-16/2/05-A
FRCMM-25/2/05-A
FRCMM-40/2/05-A
FRCMM-63/2/05-A
-
-
FRCMM-125/2/05-A
FRCMM-16/2/003-G/A
FRCMM-25/2/003-G/A
FRCMM-40/2/003-G/A
FRCMM-63/2/003-G/A
FRCMM-80/2/003-G/A
FRCMM-100/2/003-G/A
FRCMM-125/2/003-G/A
FRCMM-16/2/03-G/A
FRCMM-25/2/03-G/A
FRCMM-40/2/03-G/A
-
-
-
FRCMM-125/2/03-G/A
-
-
FRCmM-NA residual current circuit-breakers for North America IEC: 240/415 V; UL: 480Y/277 V
Type A, Pulse-current sensitive
FRCMM-25/2/003-A-NA
40
63
25
40
63
25
40
63
25
40
63
0.03
0.03
0.03
0.3
0.3
0.3
Type G/A (ÖVE E 8601), Short time-delayed
25 0.03
0.03
0.03
0.3
0.3
0.3
FRCMM-40/2/003-A-NA
FRCMM-63/2/003-A-NA
FRCMM-25/2/03-A-NA
FRCMM-40/2/03-A-NA
FRCMM-63/2/03-A-NA
FRCMM-25/2/003-G/A-NA
FRCMM-40/2/003-G/A-NA
FRCMM-63/2/003-G/A-NA
FRCMM-25/2/03-G/A-NA
FRCMM-40/2/03-G/A-NA
FRCMM-63/2/03-G/A-NA
EATON CA08103003Z-EN-INT
4 pole
240/415 V
Article no.
Part no.
Article no.
167113
167114
167115
167116
167117
167118
167119
167120
167121
167122
167123
167124
-
-
170382
170383
170384
170385
170386
170387
171168
170290
-
-
170291
170292
-
171170
170278
170279
170280
-
-
-
171166
170281
170430
170431
170432
170433
170434
170435
171164
170282
170283
170284
-
-
171167
FRCMM-16/4/003-A
FRCMM-25/4/003-A
FRCMM-40/4/003-A
FRCMM-63/4/003-A
FRCMM-80/4/003-A
FRCMM-100/4/003-A
FRCMM-125/4/003-A
FRCMM-16/4/03-A
FRCMM-25/4/03-A
FRCMM-40/4/03-A
FRCMM-63/4/03-A
FRCMM-80/4/03-A
FRCMM-100/4/03-A
FRCMM-125/4/03-A
FRCMM-16/4/05-A
FRCMM-25/4/05-A
FRCMM-40/4/05-A
FRCMM-63/4/05-A
FRCMM-80/4/05-A
FRCMM-100/4/05-A
FRCMM-125/4/05-A
FRCMM-16/4/003-G/A
FRCMM-25/4/003-G/A
FRCMM-40/4/003-G/A
FRCMM-63/4/003-G/A
FRCMM-80/4/003-G/A
FRCMM-100/4/003-G/A
FRCMM-125/4/003-G/A
FRCMM-16/4/03-G/A
FRCMM-25/4/03-G/A
FRCMM-40/4/03-G/A
FRCMM-63/4/03-G/A
FRCMM-80/4/03-G/A
FRCMM-100/4/03-G/A
FRCMM-125/4/03-G/A
FRCMM-40/4/03-S/A
FRCMM-63/4/03-S/A
IEC: 240/415 V; UL: 480Y/277 V
FRCMM-25/4/003-A-NA
FRCMM-40/4/003-A-NA
FRCMM-63/4/003-A-NA
FRCMM-25/4/03-A-NA
FRCMM-40/4/03-A-NA
FRCMM-63/4/03-A-NA
FRCMM-25/4/003-G/A-NA
FRCMM-40/4/003-G/A-NA
FRCMM-63/4/003-G/A-NA
FRCMM-25/4/03-G/A-NA
FRCMM-40/4/03-G/A-NA
FRCMM-63/4/03-G/A-NA
167125
167102
167103
167104
167105
167106
167107
167108
167109
167110
167111
167112
Complete assortment -> www.eaton.eu/ecat
170293
170294
170295
170296
170297
170298
171178
170302
170303
170304
170305
170306
170307
171180
170448
170449
170340
170341
170342
170343
170344
170345
171176
170346
170285
170332
170333
170334
170335
170336
171174
170347
170348
170349
170350
170351
171177
CA08103003Z_MOEM2015-EN.book Seite 261 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Residual current circuit breakers FRC-NA, FBS, FBH residual current circuit-breaker unit
Circuit-breaker
Residual current circuit breakers FRC-NA, FBS, FBH residual current circuit-breaker unit
Rated current
I n
A
Rated fault current
I
Δ N
A
Residual current circuit breakers FRCmM-NA-110 for North
America
63
25
40
63
IEC: 110/190 V; UL: 208/120 V
Type A, Pulse-current sensitive
25
40
25
40
63
Type G/A (ÖVE E 8601), Short time-delayed
25 0.03
40
63
0.03
0.03
0.3
0.3
0.3
0.03
0.03
0.03
0.3
0.3
0.3
Add-on residual current protection unit FBSmV
63
40
63
63
40
63
40
40
63
40
240/415 V
(please enquire for products for 120 V and 440 V)
Type A, Pulse-current sensitive
0.03
0.03
0.1
63
40
63
Type S/A, selective switch off
40
0.5
1
1
0.1
0.3
0.3
0.5
0.1
0.1
0.3
0.3
Add-on residual current protection unit FBHmV
125
80
125
80
240/415 V
(please enquire for products for 440 V)
Type A, Pulse-current sensitive
80
125
80
0.03
0.03
0.3
0.3
0.5
0.5
1
1
80
125
80
125
125
Type A, selective switch off
80
125
0.3
0.3
1
1
0.5
0.5
2 pole
Part no.
FBSMV-40/2/003-A
FBSMV-63/2/003-A
FBSMV-40/2/01-A
FBSMV-63/2/01-A
FBSMV-40/2/03-A
FBSMV-63/2/03-A
FBSMV-40/2/05-A
FBSMV-63/2/05-A
FBSMV-40/2/1-A
FBSMV-63/2/1-A
FBSMV-40/2/01-S/A
FBSMV-63/2/01-S/A
FBSMV-40/2/03-S/A
FBSMV-63/2/03-S/A
4 pole
Article no.
Part no.
-
-
-
-
-
-
FRCMM-25/2/003-G/A-NA-110
FRCMM-40/2/003-G/A-NA-110
FRCMM-63/2/003-G/A-NA-110
FRCMM-25/2/03-G/A-NA-110
FRCMM-40/2/03-G/A-NA-110
FRCMM-63/2/03-G/A-NA-110
167693
167694
167695
167696
167697
167698
-
-
-
-
-
-
170207
170208
170209
170210
170211
170212
170213
170214
170215
170216
170158
170159
170160
170161
Article no.
FRCMM-25/4/003-A-NA-110
FRCMM-40/4/003-A-NA-110
FRCMM-63/4/003-A-NA-110
FRCMM-25/4/03-A-NA-110
FRCMM-40/4/03-A-NA-110
FRCMM-63/4/03-A-NA-110
FRCMM-25/4/003-G/A-NA-110
FRCMM-40/4/003-G/A-NA-110
FRCMM-63/4/003-G/A-NA-110
FRCMM-25/4/03-G/A-NA-110
FRCMM-40/4/03-G/A-NA-110
FRCMM-63/4/03-G/A-NA-110
167705
167706
167707
167708
167709
167710
167699
167700
167701
167702
167703
167704
FBSMV-40/4/003-A
FBSMV-63/4/003-A
FBSMV-40/4/01-A
FBSMV-63/4/01-A
FBSMV-40/4/03-A
FBSMV-63/4/03-A
FBSMV-40/4/05-A
FBSMV-63/4/05-A
FBSMV-40/4/1-A
FBSMV-63/4/1-A
FBSMV-40/4/01-S/A
FBSMV-63/4/01-S/A
FBSMV-40/4/03-S/A
FBSMV-63/4/03-S/A
FBHMV-80/2/003-A
FBHMV-125/2/003-A
FBHMV-80/2/03-A
FBHMV-125/2/03-A
FBHMV-80/2/05-A
FBHMV-125/2/05-A
FBHMV-80/2/1-A
FBHMV-125/2/1-A
FBHMV-80/2/03-S/A
FBHMV-125/2/03-S/A
FBHMV-80/2/05-S/A
FBHMV-125/2/05-S/A
FBHMV-80/2/1-S/A
FBHMV-125/2/1-S/A
170137
170138
170139
170140
170141
170170
170257
170258
170259
170260
170261
170262
170263
170264
EATON CORPORATION CA08103003Z-EN
FBHMV-80/4/003-A
FBHMV-125/4/003-A
FBHMV-80/4/03-A
FBHMV-125/4/03-A
FBHMV-80/4/05-A
FBHMV-125/4/05-A
FBHMV-80/4/1-A
FBHMV-125/4/1-A
FBHMV-80/4/03-S/A
FBHMV-125/4/03-S/A
FBHMV-80/4/05-S/A
FBHMV-125/4/05-S/A
FBHMV-80/4/1-S/A
FBHMV-125/4/1-S/A
170227
170228
170229
170230
170231
170232
170233
170234
170235
170236
170166
170167
170168
170169
170171
170172
170173
170174
170175
170176
170265
170130
170131
170132
170133
170134
170135
170136
261
CA08103003Z_MOEM2015-EN.book Seite 261 Donnerstag, 7. April 2016 12:02 12
Moeller® series
Residual current circuit breakers FRC-NA, FBS, FBH residual current circuit-breaker unit
Circuit-breaker
Residual current circuit breakers FRC-NA, FBS, FBH residual current circuit-breaker unit
Rated current
I n
A
Rated fault current
I
Δ N
A
Residual current circuit breakers FRCmM-NA-110 for North
America
63
25
40
63
IEC: 110/190 V; UL: 208/120 V
Type A, Pulse-current sensitive
25
40
25
40
63
Type G/A (ÖVE E 8601), Short time-delayed
25 0.03
40
63
0.03
0.03
0.3
0.3
0.3
0.03
0.03
0.03
0.3
0.3
0.3
Add-on residual current protection unit FBSmV
63
40
63
63
40
63
40
40
63
40
240/415 V
(please enquire for products for 120 V and 440 V)
Type A, Pulse-current sensitive
0.03
0.03
0.1
63
40
63
Type S/A, selective switch off
40
0.5
1
1
0.1
0.3
0.3
0.5
0.1
0.1
0.3
0.3
Add-on residual current protection unit FBHmV
125
80
125
80
240/415 V
(please enquire for products for 440 V)
Type A, Pulse-current sensitive
80
125
80
0.03
0.03
0.3
0.3
0.5
0.5
1
1
80
125
80
125
125
Type A, selective switch off
80
125
0.3
0.3
1
1
0.5
0.5
Complete assortment -> www.eaton.eu/ecat
2 pole
Part no.
FBSMV-40/2/003-A
FBSMV-63/2/003-A
FBSMV-40/2/01-A
FBSMV-63/2/01-A
FBSMV-40/2/03-A
FBSMV-63/2/03-A
FBSMV-40/2/05-A
FBSMV-63/2/05-A
FBSMV-40/2/1-A
FBSMV-63/2/1-A
FBSMV-40/2/01-S/A
FBSMV-63/2/01-S/A
FBSMV-40/2/03-S/A
FBSMV-63/2/03-S/A
4 pole
Article no.
Part no.
-
-
-
-
-
-
FRCMM-25/2/003-G/A-NA-110
FRCMM-40/2/003-G/A-NA-110
FRCMM-63/2/003-G/A-NA-110
FRCMM-25/2/03-G/A-NA-110
FRCMM-40/2/03-G/A-NA-110
FRCMM-63/2/03-G/A-NA-110
167693
167694
167695
167696
167697
167698
-
-
-
-
-
-
170207
170208
170209
170210
170211
170212
170213
170214
170215
170216
170158
170159
170160
170161
Article no.
FRCMM-25/4/003-A-NA-110
FRCMM-40/4/003-A-NA-110
FRCMM-63/4/003-A-NA-110
FRCMM-25/4/03-A-NA-110
FRCMM-40/4/03-A-NA-110
FRCMM-63/4/03-A-NA-110
FRCMM-25/4/003-G/A-NA-110
FRCMM-40/4/003-G/A-NA-110
FRCMM-63/4/003-G/A-NA-110
FRCMM-25/4/03-G/A-NA-110
FRCMM-40/4/03-G/A-NA-110
FRCMM-63/4/03-G/A-NA-110
167705
167706
167707
167708
167709
167710
167699
167700
167701
167702
167703
167704
FBSMV-40/4/003-A
FBSMV-63/4/003-A
FBSMV-40/4/01-A
FBSMV-63/4/01-A
FBSMV-40/4/03-A
FBSMV-63/4/03-A
FBSMV-40/4/05-A
FBSMV-63/4/05-A
FBSMV-40/4/1-A
FBSMV-63/4/1-A
FBSMV-40/4/01-S/A
FBSMV-63/4/01-S/A
FBSMV-40/4/03-S/A
FBSMV-63/4/03-S/A
FBHMV-80/2/003-A
FBHMV-125/2/003-A
FBHMV-80/2/03-A
FBHMV-125/2/03-A
FBHMV-80/2/05-A
FBHMV-125/2/05-A
FBHMV-80/2/1-A
FBHMV-125/2/1-A
FBHMV-80/2/03-S/A
FBHMV-125/2/03-S/A
FBHMV-80/2/05-S/A
FBHMV-125/2/05-S/A
FBHMV-80/2/1-S/A
FBHMV-125/2/1-S/A
170137
170138
170139
170140
170141
170170
170257
170258
170259
170260
170261
170262
170263
170264
EATON CA08103003Z-EN-INT
FBHMV-80/4/003-A
FBHMV-125/4/003-A
FBHMV-80/4/03-A
FBHMV-125/4/03-A
FBHMV-80/4/05-A
FBHMV-125/4/05-A
FBHMV-80/4/1-A
FBHMV-125/4/1-A
FBHMV-80/4/03-S/A
FBHMV-125/4/03-S/A
FBHMV-80/4/05-S/A
FBHMV-125/4/05-S/A
FBHMV-80/4/1-S/A
FBHMV-125/4/1-S/A
170171
170172
170173
170174
170175
170176
170265
170130
170131
170132
170133
170134
170135
170136
170227
170228
170229
170230
170231
170232
170233
170234
170235
170236
170166
170167
170168
170169
CA08103003Z_MOEM2015-EN.book Seite 262 Donnerstag, 7. April 2016 12:02 12
Circuit-breaker
FRB combined residual-current/power circuit-breakers
FRB combined residual-current/power circuit-breakers
Moeller® series
Rated current
I n
A
FRBmM combined residual-current/power circuit-breakers
16
20
25
32
40
4
6
10
13
Rated fault current
I
Δ N
A
Digital FRBmM residual current operated circuit-breakers with overcurrent protection
6
10
13
16
13
16
20
25
20
25
6
Type A, Pulse-current sensitive, 240 V
1 pole+N, Short time-delayed
6
10
0.01
0.01
0.01
0.01
0.01
0.01
0.03
0.03
0.03
0.03
0.03
0.03
0.1
0.1
0.1
0.1
0.1
0.1
13
16
20
25
6
10
13
16
13
16
20
25
20
25
6
10
10
13
16
20
25
2 pole, Short time-delayed
6
10
0.03
0.03
0.03
0.03
0.1
0.1
0.01
0.01
0.03
0.03
0.01
0.01
0.01
0.01
0.1
0.1
0.1
0.1
Type A, Pulse-current sensitive, 240 V (please enquire for products for other voltage ranges)
1 pole+N, non-delayed
2
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
Tripping characteristic: B
Response current of short-circuit release
3-5 x I n
Part no.
Article no.
Tripping characteristic: C
Response current of short-circuit release
5-10 x I
Part no.
n
Article no.
Tripping characteristic: D
Response current of short-circuit release
10-20 x I n
Part no.
Article no.
-
-
-
-
-
-
-
-
-
-
-
-
FRBDM-B10/1N/001-G/A 168249
FRBDM-B13/1N/001-G/A 168250
FRBDM-B16/1N/001-G/A 168251
-
-
-
-
-
FRBDM-B10/1N/003-G/A 168264
-
-
-
FRBDM-B13/1N/003-G/A 168265
FRBDM-B16/1N/003-G/A 168266
-
-
-
FRBDM-B10/1N/01-G/A
FRBDM-B13/1N/01-G/A
FRBDM-B16/1N/01-G/A
-
168279
168280
-
168281
FRBDM-B10/2/001-G/A
FRBDM-B13/2/001-G/A
FRBDM-B16/2/001-G/A
FRBDM-B10/2/003-G/A
FRBDM-B13/2/003-G/A
FRBDM-B16/2/003-G/A
FRBDM-B10/2/01-G/A
FRBDM-B13/2/01-G/A
FRBDM-B16/2/01-G/A
-
168294
168295
168296
-
-
-
168198
-
-
168199
168200
-
168213
-
-
168214
168215
-
-
FRBMM-B6/1N/003-A
FRBMM-B10/1N/003-A
FRBMM-B13/1N/003-A
FRBMM-B16/1N/003-A
FRBMM-B20/1N/003-A
FRBMM-B25/1N/003-A
FRBMM-B32/1N/003-A
FRBMM-B40/1N/003-A
EATON CA08103003Z-EN-INT
FRBDM-C6/1N/001-G/A 168252
FRBDM-C10/1N/001-G/A 168253
FRBDM-C13/1N/001-G/A 168254
FRBDM-C16/1N/001-G/A 168255
FRBDM-C20/1N/001-G/A 168256
FRBDM-C25/1N/001-G/A 168257
FRBDM-C6/1N/003-G/A 168267
FRBDM-C10/1N/003-G/A 168268
FRBDM-C13/1N/003-G/A 168269
FRBDM-C16/1N/003-G/A 168270
FRBDM-C20/1N/003-G/A 168271
FRBDM-C25/1N/003-G/A 168272
FRBDM-C6/1N/01-G/A 168282
FRBDM-C10/1N/01-G/A 168283
FRBDM-C13/1N/01-G/A 168284
FRBDM-C16/1N/01-G/A 168285
FRBDM-C20/1N/01-G/A 168286
FRBDM-C25/1N/01-G/A 168287
FRBDM-C6/2/001-G/A
FRBDM-C10/2/001-G/A
FRBDM-C13/2/001-G/A
FRBDM-C16/2/001-G/A
FRBDM-C20/2/001-G/A
FRBDM-C25/2/001-G/A
FRBDM-C6/2/003-G/A
FRBDM-C10/2/003-G/A
FRBDM-C13/2/003-G/A
FRBDM-C16/2/003-G/A
FRBDM-C20/2/003-G/A
FRBDM-C25/2/003-G/A
FRBDM-C6/2/01-G/A
FRBDM-C10/2/01-G/A
FRBDM-C13/2/01-G/A
FRBDM-C16/2/01-G/A
FRBDM-C20/2/01-G/A
FRBDM-C25/2/01-G/A
168297
168298
168299
168300
168301
168302
168201
168202
168203
168204
168205
168206
168216
168217
168218
168219
168220
168221
-
-
170702
170703
170704
170705
170706
170707
170708
170709
FRBMM-C2/1N/003-A
FRBMM-C4/1N/003-A
FRBMM-C6/1N/003-A
FRBMM-C10/1N/003-A
FRBMM-C13/1N/003-A
FRBMM-C16/1N/003-A
FRBMM-C20/1N/003-A
FRBMM-C25/1N/003-A
FRBMM-C32/1N/003-A
FRBMM-C40/1N/003-A
FRBDM-D6/1N/001-G/A 168258
FRBDM-D10/1N/001-G/A 168259
FRBDM-D13/1N/001-G/A 168260
FRBDM-D16/1N/001-G/A 168261
FRBDM-D20/1N/001-G/A 168262
FRBDM-D25/1N/001-G/A 168263
FRBDM-D6/1N/003-G/A 168273
FRBDM-D10/1N/003-G/A 168274
FRBDM-D13/1N/003-G/A 168275
FRBDM-D16/1N/003-G/A 168276
FRBDM-D20/1N/003-G/A 168277
FRBDM-D25/1N/003-G/A 168278
FRBDM-D6/1N/01-G/A 168288
FRBDM-D10/1N/01-G/A 168289
FRBDM-D1