Assembly Instruction Sheet #IS-SER5009IF
For Style SER5009IF
Tools Required: Flathead screwdriver, Phillips screwdriver, pliers, wire cutters, wire strippers, electrical tape, safety glasses.
Bulb Recommended:
(9) Candelabra Base 60W Maximum, Alternate bulb (9) 13W CFL
Estimated Assembly Time:
30-45 minutes
Preparation: Identify and inspect all parts before beginning installation. Check package content list and diagrams below to be sure all parts are present. If any parts are missing or damaged, do not attempt to assemble, install, or operate the fixture. Contact customer service for replacement parts.
Warnings and Cautions
Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.
These instructions are provided for your safety. It is very important you read them completely before installing the fixture. We strongly recommend that a licensed, professional electrician perform the installation.
Disconnect fixture from power source before replacing bulbs. Make sure bulbs are given sufficient time to cool before removal. Do not subject glass parts to any shock while in operation or shattering may result.
Package Contents Hardware Contents
QUOIZEL
R
A
Fixture Loop x 1
D
Banding Iron x 3
B
Lock Ball x 3
C
Lock Screw x 3
Socket Assembly x 1
F
E
Center
Column x 1
AA
Crossbar x 1
BB
Lock Washer x 2
CC
Hex Nut x 2
DD
Nipple x 1
EE
Canopy Chain Loop x 1
FF
Canopy Lock Ring x 1
GG
Fixture Chain x 1
HH
Quick Link x 2
II
Ceiling Canopy x 1
STEP 1 Install Center Column
A. Thread the end of the Center Column (E) onto the nipple on the top center of the
Socket Assembly (F). Line up the Holes on the bottom of the upper body and the
Mounting Holes on the top of the junction box before tighten them together.
Figure 1
F
Hole
E
Mounting
Hole
STEP 3 Install Fixture Loop
A. Thread the Fixture Loop (A) onto the nipple in the top center of the Center Column (E). Hand tighten until snug.
A
E
Figure 3
STEP 4
-
Install Crossbar
A.
Attach the Crossbar ( AA) to the Outlet Box with the head of the
Green Ground Screw facing you. Secure it with Outlet Box Screws
(not included)
.
Tighten until snug
.
STEP 2
-
Install Decorative Arms
A. Line up the Hole on the end of the
Banding Iron (D) to the Mounting Hole on the top of the Junction Box and secure with the Lock Screw (C). Do not tighten the Lock Screw (C) now.
B. Insert the nipple at the top end of the
Banding Iron (D) into the Hole on the bottom of the Upper Body and secure with the Lock Ball (B). Tighten the Lock
Ball (B) and Lock Screw (C) until the
Banding Iron (D) is tighten.
2014 QuoizelInc.
Hole
Mounting
Hole
C
B
Figure 2
D
Outlet Box
AA
Outlet Box Screw
(not included)
Green Ground Screw
STEP 5 Install Canopy Chain Loop and Nipple
Figure 4
*
Pliers is required for this step.
A. Thread one Hex Nut (CC) to one end of the Nipple (DD) until it is at least 0.25” from the end. Pass one Lock Washer (BB) over the end of
Thank you for purchasing a Quoizel product.
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700 or visit us on-line at www.quoizel.com
May2014
1of3
the Nipple (DD) and thread the Canopy Chain Loop (EE) onto the
Nipple (DD). By using pliers, thread the Hex Nut (CC) against the
Canopy Chain Loop (EE) and hand tighten until snug.
B. Thread another Hex Nut (CC) to the middle of the Nipple (DD). Place another Lock Washer (BB) over the Nipple (DD) and then thread the
Nipple (DD) into the Crossbar (AA) until the Nipple (DD) is about
0.375” above the Crossbar (AA).
C. Remove the Canopy Lock Ring (FF) from the Canopy Chain Loop
(EE). Place the Ceiling Canopy (II) over the Canopy Chain Loop
(EE) against the ceiling to determine the correct position of the
Nipple (DD). Thread the Canopy Lock Ring onto the Canopy Chain
Loop (EE). Adjust the Nipple (DD) to allow the Ceiling Canopy (II) to rest against the ceiling when held in place by the Canopy Lock Ring
(FF).
D. Remove the Canopy Lock Ring (FF) and the Ceiling Canopy (II).
Tighten the Hex Nut (CC) against the Crossbar (AA) to secure in place.
through the Canopy Lock Ring (FF) and the Ceiling Canopy (II) in order.
C. Attach one end of the Fixture Chain (GG) to the Fixture Loop (A) with one Quick Link (HH). Lift the fixture and Fixture Chain (GG) up And
Attach the other end of the Fixture Chain (GG) onto the Canopy
Chain Loop (EE) with another Quick Link (HH). The fixture will now hang safely. Close the chain loop at the Ceiling Canopy Loop (EE).
D. Feed the Supply Wires and Ground Wire through the Canopy Chain
Loop (EE) and Nipple (DD) into the Outlet Box. Cut the wires leaving approximately 8” of wire extending from the Outlet Box.
E. Refer to Step 7 for wire connections.
F. Raise the Ceiling Canopy (II) and Canopy Lock Ring (FF) up the
Fixture Chain (GG) and over the Canopy Chain Loop (EE). Tighten the Canopy Lock Ring (FF) onto the Canopy Chain Loop (EE) until tight.
Suggested chain length for Ceiling height :
9’ ceiling : use 7 links of chain and 2 quick links
10’ ceiling : use 16 links of chain and 2 quick links
STEP 7 - Wire Connections
AA
BB
CC
DD
CC
EE
FF
BB
II
Step B
Step A
Figure 5
A. Use standard wire connectors (not included) to make all wire connections. (Connectors are not included with fixture.) Strip and prepare wire ends according to instructions supplied with connectors.
B. Connect White Supply Wire from the Outlet Box to Ribbed side Wire from fixture.
C. Connect Black (or Red) Supply Wire from the Outlet Box to Smooth side Wire from fixture.
D. Connect Ground Wire from the Outlet Box to Ground Wire from fixture.
E. Twist connectors until wires are tightly joined together.
F. Wrap each connection with approved electrical tape and carefully stuff all the connected wires into the Outlet Box.
STEP 6 - Install Fixture Chain and Ceiling Canopy
A. Adjust the Fixture Chain (GG) to your desired length by removing the links if needed.
*
Pliers is required for this step.
B. With the Fixture Chain (GG) not attached to the Fixture Loop (A) and the Canopy Chain Loop (EE), pull the supply wires through the
Fixture Chain (GG) alternating links. After the wires are through the
Fixture Chain (GG), pull the Supply Wires and the Ground Wire
White wire from supply
Black wire from supply (or Red)
Ground wire from supply
Figure 7
Ribbed side wire from fixture
Smooth side wire from fixture
Ground wire from fixture
STEP 8 - Install Bulb
Supply Wires and Ground Wire DD
EE
HH
A. This fixture uses candelabra bulb with standard screw base. Maximum 60 watts.
B. Insert bulb and screw snugly into place.
Your fixture is now assembled and ready to use. Enjoy!
Bulb
Figure 8
GG
II
2014 QuoizelInc.
FF
HH
A
Figure 6
Thank you for purchasing a Quoizel product.
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700 or visit us on-line at www.quoizel.com
2of3
May2014
SER5009IF
FINISH: ITALIAN FRESCO
QUOIZEL
R
NOTE: SEVEN LIGHTS SHOWN FOR
ILLUSTRATION PURPOSES ONLY.
5” Dia.
1”
136”
OVERALL HEIGHT
(
INCLUDES 96” CHAIN
AND 2 QUICK LINKS
)
34”
(9) 60W Candelabra
Base Bulbs
(Not Supplied)
NO.
PART NUMBER
1
30” Dia.
NOTE: ALL DIMENSIONS ARE ROUNDED UP TO THE NEAREST 1/2 "
REPLACEMENT PART DESCRIPTION REQ.
2014 QuoizelInc.
Thank you for purchasing a Quoizel product.
Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700 or visit us on-line at www.quoizel.com
3of3
May2014

Public link updated
The public link to your chat has been updated.
Advertisement