Hikvision DS-KD8003-IME2 Video Türsprech Station, 2MP Kamera, H.264, IR, IP65, 2-Draht Owner's Manual
Hikvision DS-KD8003-IME2 is a high-tech video intercom system designed for secure and convenient communication and access control. It allows for two-way audio and video communication, remote door unlocking, and integration with other smart home devices. With its vandal-resistant design and IP65 weatherproof rating, it is suitable for various outdoor scenarios.
Advertisement
Advertisement
Door Station
Installation Guide
Door Station Installation Guide
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol
Danger
Description
Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury.
Caution
Note
Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
Provides additional information to emphasize or supplement important points of the main text.
i
Door Station Installation Guide
Contents
3.3.1 Two-Module Surface Mounting .............................................................. 16
3.3.2 Two-Module Flush Mounting ................................................................. 21
3.4.1 Three-Module Surface Installation ......................................................... 25
3.4.2 Three-Module Flush Mounting ............................................................... 31
3.5.1 More-Than-Three Module Surface Mounting ........................................ 35
3.5.2 More-Than-Three Module Flush Mounting ............................................ 41
ii
Door Station Installation Guide
iii
1 Appearance
Door Station Installation Guide
Front and Side Panel
6
7
2
3
4
5
No.
1
Figure 1-1 Front and Side Panel
Table 1-1 Appearance Description
Description
Microphone
Low Illumination IR Supplement Light
Built-in Camera
Loudspeaker
Call Button
Nametag
TAMPER
1
Bottom Panel
Door Station Installation Guide
No.
8
9
10
Figure 1-2 Bottom Panel
Table 1-2 Appearance Description
Description
Network Interface
Module-connecting Interface (output)
Terminals
2
Door Station Installation Guide
2 Terminal and Wiring
2.1 Terminal Description
A8
B1
B2
B3
B4
B5
A4
A5
A6
A7
No.
A1
A2
A3
Figure 2-1 Terminals and Interfaces
Table 2-1 Descriptions of Terminals and Interfaces
GND
AIN1
AIN2
AIN3
AIN4
485-
Interface
NC1
NO1
COM
NC2
NO2
GND
12 VDC
Description
Door Lock Relay Output (NC)
Door Lock Relay Output (NO)
Common Interface
Door Lock Relay Output (NC)
Door Lock Relay Output (NO)
Grounding
Power Supply Output
Grounding
For the access of Door Magnetic 2
For the access of Door Magnetic 1
For the access of Exit Button 1
For the access of Exit Button 2
Module-connecting Interface
3
No.
B6
B7
B8
C
Interface
485+
12 V OUT
GND
LAN
Door Station Installation Guide
Description
Power and Network Interface
2.2 Wiring Description
2.2.1 Power Supply Wiring
Caution
Make sure all the related equipment is power-off during the installation.
Wire the devices with power supply cables as picture shown below.
Door station should be connected to CH6 of the video/audio distributor with twowire cables.
Indoor Station should be connected to any terminal of CH1 to CH5 of the video/ audio distributor with two-wire cables.
4
Door Station Installation Guide
2.2.2 Door Lock Wiring
Figure 2-2 Wiring Description
Figure 2-3 Door Lock Wiring
5
Door Station Installation Guide
Note
• Terminal NC1/COM is set as default for accessing magnetic lock/electric bolt; terminal NO2/COM is set as default for accessing electric strike.
• Lock should be powered by itself. Max. voltage and current for relay is 30V and
1A.
2.2.3 Door Magnetic Wiring
Figure 2-4 Door Magnetic Wiring
Note
AIN1 and AIN2 are defaulted to connect door magnetic. Door magnetic connected to
AIN1 detects status of the lock that connected to NC1/NO1; Door magnetic connected to AIN2 detects the status of the lock connected to NC2/NO2.
2.2.4 Exit Button Wiring
6
Door Station Installation Guide
Figure 2-5 Exit Button Wiring
Note
AIN3 and AIN4 are set as default for connecting exit button. Exit button connected to
AIN3 opens the lock connected to NC1/NO1; Exit button connected to AIN4 controls the lock that connected to NC2/NO2.
7
3 Installation
Door Station Installation Guide
Note
• Make sure the device in the package is in good condition and all the assembly parts are included.
• Make sure the place for surface mounting is flat.
• Make sure all the related equipment is power-off during the installation.
• Tools that you need to prepare for installation:
Drill (ø6), cross screwdriver (PH1*150 mm), and gradienter.
3.1 Configure Sub Module Address
You need to set the sub module address via DIP before installation.
Steps
1. Remove the rubber cover on the sub module rear panel to expose the DIP switch.
Figure 3-1 DIP Switch
2. Set the sub module address according to the DIP rules, and install the rubber cover back.
Note
• Digit 1, 2, 3, 4 are used to coding the sub module address; Digit 5, 6, 7 are reserved; Digit 8 is a resistance (120Ω) is you set it as on.
• Valid sub module address range is 1 to 8. The No. should be unique for sub modules that connected to the same main unit.
8
Door Station Installation Guide
The sub module address and corresponding switch status as below.
Table 3-1 Description
Digit 1 Digit 2 Digit 3 Digit 4
6
7
8
4
5
2
3
Sub Module
Address
1 ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
3.2 One-Module Installation
3.2.1 Surface Mounting
Before You Start
Figure 3-2 Mounting Frame
9
Door Station Installation Guide
Note
• The dimension of one module mounting frame is: 117(W)×107(H)×32.7(D) mm.
• The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension.
Steps
1. Paste the installation Sticker 1 onto the wall. Make sure the sticker is placed leveled via measuring with the gradienter.
2. Chisel 4 holes with drill align to the screw holes on the sticker.
Note
• The suggested size of hole is 6 (diameter) × 25 (depth) mm.
• The suggested length of cables left outside is 100 mm.
Figure 3-3 Chisel Screw Hole
3. Remove the stricker and insert the expansion sleeves into the screw holes.
4. Fix the mounting frame onto the wall with 4 expansion bolts.
10
Door Station Installation Guide
Figure 3-4 Fix the Mounting Frame
5. Connect the cables to the corresponding interfaces of the main unit and insert it into the frame.
Figure 3-5 Insert the Main Unit
6. Fix the cover onto the frame.
11
Door Station Installation Guide
3.2.2 Flush Mounting
Before You Start
Figure 3-6 Fix the Cover
Figure 3-7 Front and Side View of the Gang Box
12
Door Station Installation Guide
Figure 3-8 Gang Box
Note
• The dimension of one-module gang box is: 115(W)×134(H)×56(D) mm.
• The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension.
Steps
1. Cave the installation hole, and pull the cable out.
Note
• The suggested dimension of installation hole is 118(L)×108(W)×45.5(D) mm.
• The suggested length of cables left outside is 100 mm.
13
Door Station Installation Guide
Figure 3-9 Cave the Installation Hole
2. Remove the plastic sheet in the cable entry.
3. Insert the gang box into the hole and pull out the cables through the cable entry.
Mark the screw holes' position with a marker, and take out the gang box.
Figure 3-10 Mark the Screw Holes
4. Chisel 4 holes with drill align to marks on the wall, and insert the expansion sleeves into the screw holes.
Note
The suggested size of hole is 6 (diameter) × 45 (depth) mm.
5. Fix the gang box with 4 expansion bolts.
14
Door Station Installation Guide
Figure 3-11 Fix the Gang Box
6. Fill and level up the gap between the gang box and wall with concrete. Remove the 4 mounting ears with tool after concrete is dry.
Figure 3-12 Remove the Mounting Ears
7. Insert the mounting frame together with the locating plates into the hole, and fix it with 4 expansion bolts.
8. Connect the cables to the corresponding interfaces of the main unit and insert it into the gang box.
15
Door Station Installation Guide
Figure 3-13 Insert the Main Unit
9. Use the hexagon wrench in the package fix the cover.
Figure 3-14 Fix the Cover
3.3 Two-Module Installation
3.3.1 Two-Module Surface Mounting
16
Before You Start
Door Station Installation Guide
Figure 3-15 Mounting Frame
Note
• The dimension of two-module mounting frame is: 219(W)×107 (H)×32.7(D) mm.
• The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension.
Steps
1. Paste the installation Sticker 1 onto the wall. Make sure the sticker is placed leveled via measuring with the gradienter.
2. Chisel 4 holes with drill align to the screw holes on the sticker. The suggested size of hole is 6 (diameter) × 25 (depth) mm. The suggested length of cables left outside is 270 mm.
17
Door Station Installation Guide
Figure 3-16 Chisel Screw Holes
3. Remove the sticker and insert the expansion sleeves into the screw holes.
4. Fix the mounting frame onto the wall with 4 expansion bolts.
Figure 3-17 Fix the Mounting Frame
5. Thread the module-connecting line across the thread hole of the frame. Pass the main unit connecting lines across the thread hole to the upper grid.
18
Door Station Installation Guide
Figure 3-18 Placement of Lines
6. Connect the cables.
1) Connect the cables and module-connecting line to the corresponding interfaces of the main unit, then place the main unit into the upper grid.
2) Connect the other end of the module-connecting line to the input interface of the sub module.
3) Organize the line with cable tie in the package. The suggested line connection picture as below.
19
Door Station Installation Guide
Figure 3-19 Line Connection Effect Picture
7. Insert the modules into the frame after wiring. Main unit must be placed in the top grid.
Figure 3-20 Insert the Modules
8. Use the hexagon wrench in the package fix the cover onto the frame.
20
Door Station Installation Guide
Figure 3-21 Fix the Cover
3.3.2 Two-Module Flush Mounting
Before You Start
Figure 3-22 Gang Box
21
Door Station Installation Guide
Note
• The dimension of one-module gang box is: 237(W)×134(H)×56(D) mm.
• The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension.
Steps
1. Cave the installation hole, and pull the cable out.The suggested dimension of installation hole is 220(W)×108(H)×45.5(D) mm. The suggested length of cables left outside is 270 mm.
Figure 3-23 Cave the Installation Hole
2. Remove the plastic sheet of the cable entry which will be used.
3. Insert the gang box into the hole and pull out the cables through the cable entry.
Mark the screw holes' position with a marker, and take out the gang box.
22
Door Station Installation Guide
Figure 3-24 Mark the Screw Holes
4. Chisel 4 holes with drill align to marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) × 45
(depth) mm.
5. Fix the gang box with 4 expansion bolts.
Figure 3-25 Fix the Gang Box
6. Fill and level up the gap between the gang box and wall with concrete. Remove the mounting ears with tool after concrete is dry.
23
Door Station Installation Guide
Figure 3-26 Remove the Mounting Ears
7. Connect wires and insert the modules.
1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main unit, then place the main unit into the upper grid.
2) Connect the other end of Cable 2 to the input interface of the sub module.
Insert it into the lower grid.
Figure 3-27 Connect Wires and Insert the Modules
24
Door Station Installation Guide
Note
Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 refers to the module-connecting line in the accessory package.
8. Use the hexagon wrench in the package fix the cover.
Figure 3-28 Fix the Cover
3.4 Three-Module Installation
3.4.1 Three-Module Surface Installation
Before You Start
Figure 3-29 Mounting Frame
25
Door Station Installation Guide
Note
• The dimension of two-module mounting frame is: 320.8 (W) × 107 (H) × 32.7(D) mm.
• The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension.
Steps
1. Paste the installation sticker 1 onto the wall. Make sure the sticker is placed leveled via measuring with the gradienter.
2. Chisel 4 holes with drill align to the screw holes on the sticker.The suggested size of hole is 6 (diameter) × 25 (depth) mm. The suggested length of cables left outside is 270 mm.
Figure 3-30 Chisel Screw Hole
3. Remove the sticker and insert the expansion sleeves into the screw holes.
4. Fix the mounting frame onto the wall with 4 expansion bolts.
26
Door Station Installation Guide
Figure 3-31 Fix the Mounting Frame
Note
The mounting frame should be placed exactly as below for this step. The tamper plate should be at the low right of the first grid.
27
Door Station Installation Guide
Figure 3-32 Mounting Frame
5. Thread the module-connecting lines across the thread holes of the frame. Pass the main unit connecting lines across the thread hole to the top grid.
28
Door Station Installation Guide
Figure 3-33 Placement of Lines
6. Connect the cables.
1) Connect the cables and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid.
2) Connect the other end of the module-connecting line1 to the input interface of the sub module. Connect two sub modules via module-connecting line 2.
3) Organize the line with cable tie in the package. The suggested line connection picture as below.
29
Door Station Installation Guide
Figure 3-34 Line Connection Effect Picture
7. Insert the modules into the frame after wiring. Main unit must be placed in the top grid.
Figure 3-35 Insert the Modules into the Frame
30
Door Station Installation Guide
8. Use the hexagon wrench in the package fix the cover onto the frame.
Figure 3-36 Fix the Cover
3.4.2 Three-Module Flush Mounting
31
Before You Start
Door Station Installation Guide
Figure 3-37 Gang Box
Note
• The dimension of one-module gang box is: 338.8(W)×134(H)×56(D) mm.
• The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension.
Steps
1. Cave the installation hole, and pull the cable out.The suggested dimension of installation hole is 321.8(W)×108(H)×45.5(D) mm. The suggested length of cables left outside is 270 mm.
32
Door Station Installation Guide
Figure 3-38 Cave the Installation Hole
2. Remove the plastic sheet of the cable entry which will be used.
3. Insert the gang box into the hole and pull out the cables through the cable entry.
Mark the screw holes’ position with a marker, and take out the gang box.
Figure 3-39 Mark the Screw Holes
4. Chisel 4 holes with drill align to marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) × 45
(depth) mm.
5. Fix the gang box with 4 expansion bolts.
33
Door Station Installation Guide
Figure 3-40 Fix the Gang Box
6. Fill and level up the gap between the gang box and wall with concrete. Remove the mounting ears with tool after concrete is dry.
Figure 3-41 Remove the Mounting Ears
7. Connect wires and insert the modules.
1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the Main Unit, then place the Main Unit into the upper grid.
2) Connect the other end of Cable 2 to the input interface of Sub Module 1.
Connect one end of Cable 3 to the output interface of Sub Module 1 and insert it into the middle grid.
3) Connect the other end of Cable 3 to the input interface of Sub Module 2.
Insert it into the bottom grid.
34
Door Station Installation Guide
Figure 3-42 Connect Wires and Insert Modules
Note
Cable 1 refers to the cables pulled out from the wall that connected to the main unit. Cable 2 and Cable 3 refer to the module-connecting line in the accessory package.
8. Use the hexagon wrench in the package to fix the cover onto the gang box.
Figure 3-43 Fix the Cover
3.5 More-Than-Three Module Installation
3.5.1 More-Than-Three Module Surface Mounting
35
Before You Start
Door Station Installation Guide
Figure 3-44 Mounting Frame
Note
• It takes two three-module mounting frames. The dimension of three-module mounting frame is: 320.8(W)×107 (H)×32.7(D) mm.
• The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension.
Steps
1. Paste two Sticker 1 onto the wall. Make sure the stickers are placed leveled via measuring with the gradienter.
2. Chisel 8 holes with drill align to the screw holes on the sticker. The suggested size of hole is 6 (diameter) × 25 (depth) mm. The suggested length of cables left outside is 270 mm.
3. Pull out the cable through the cable hole of the left sticker.
36
Door Station Installation Guide
Figure 3-45 Chisel Screw Holes
4. Remove the stickers and insert the expansion sleeves into the screw holes.
5. Thread the module-connecting line (400 mm) and grounding line across the thread hole of both frames.
Figure 3-46 Place the Grounding Line and Module-Connecting Line
37
Door Station Installation Guide
Note
• There are 6 module-connecting lines in the package: 190 mm × 4 and 400 mm × 2.
• Take the 400 mm one for this step.
• The green-yellow line in the package is for grounding.
6. Fix the mounting frame onto the wall with 8 expansion bolts.
Figure 3-47 Fix the Mounting Frame
7. Pass the main unit connecting lines across the thread hole to the top grid of the left frame. Thread the module-connecting line (190 mm) across the thread hole of the frame. The lines should be placed as below:
8. Connect the cables.
Figure 3-48 Placement of Lines
38
Door Station Installation Guide
1) Connect the cables and module-connecting line 1 to the corresponding interfaces of the main unit, then place the main unit into the upper grid.
2) Connect the other end of the module-connecting line1 to the input interface of the sub module. Connect all sub modules via module-connecting lines.
3) Organize the line with cable tie in the package. The suggested line connection picture as below.
Figure 3-49 Line Connection Effect Picture
9. Insert the modules into the frame after wiring. Main unit must be placed in the top grid on the left.
39
Door Station Installation Guide
Figure 3-50 Insert the Modules
10. Pull the grounding line out and fixed its two end to the screw on the cover.
Figure 3-51 Connect the Grounding Line to the Cover
11. Use the hexagon wrench in the package fix the cover onto the frame.
40
Door Station Installation Guide
Figure 3-52 Fix the Cover
3.5.2 More-Than-Three Module Flush Mounting
41
Before You Start
Door Station Installation Guide
Figure 3-53 Gang Box
Note
• It takes two three-module gang boxes. The dimension of the gang box is: 338.8
(W) × 134 (H) × 56 (D) mm.
• The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension.
42
Door Station Installation Guide
Steps
1. Cave the installation hole, and pull the cable out.The suggested dimension of installation hole is 321.8 (W) × 315 (H) × 45.5 (D) mm. The suggested length of cables left outside is 270 mm.
Figure 3-54 Cave the Installation Hole
2. Connect two gang boxes as below.
Figure 3-55 Connect Two Gang Boxes
3. Remove the plastic sheet of the cable entry which will be used.
43
Door Station Installation Guide
4. Remove the plastic sheets on the side of the gang boxes (shown as 1 and 2) below:
Figure 3-56 Remove the Plastic Sheets
5. Insert the gang boxes into the hole and pull out the cables through the cable entry. Mark the screw holes' position with a marker, and take out the gang boxes.
Figure 3-57 Mark the Screw Holes
6. Chisel 8 holes with drill align to marks on the wall, and insert the expansion sleeves into the screw holes. The suggested size of hole is 6 (diameter) × 45
(depth) mm.
7. Fix the gang boxes with 8 expansion bolts.
44
Door Station Installation Guide
Figure 3-58 Fix the Gang Boxes
8. Fill and level up the gap between the gang box and wall with concrete. Remove the mounting ears with tool after concrete is dry. Pass the grounding line through the cable entries.
Figure 3-59 Remove the Mounting Ears
Note
The green-yellow line in the package is for grounding.
9. Connect wires and insert the modules.
1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the Main Unit, then place the Main Unit into the upper grid of the left gang box.
45
Door Station Installation Guide
2) Connect the other end of Cable 2 to the input interface of Sub Module 1.
Connect one end of Cable 3 to the output interface of Sub Module 1 and insert it into the middle grid of the left gang box.
3) Finish the wiring and inserting according to the cable number and the position shown as below.
Figure 3-60 Install Mounting Frame
The cables connect to each module shown as below.
Figure 3-61 Cables Connection
46
Door Station Installation Guide
Note
• Cable 2,3,5 and 6 are the module-connecting lines (190 mm) in the package.
• Cable 4 is the module-connecting line (400 mm) in the package.
• Main unit must be put in the top grid.
10. Pull the grounding line out and fixed its two end to the screw on the cover.
Figure 3-62 Connect the Grounding Line to the Cover
11. Use the hexagon wrench in the package fix the cover onto the gang box.
47
Door Station Installation Guide
Figure 3-63 Fix the Cover
48
Door Station Installation Guide
A. Extension Modules
Module Door station has the modules below:
Table A-1 Modules
Model
DS-KD-KK
Appearance Description
Nametag Module
DS-KD-IN
DS-KD-KP
DS-KD-M(E)
DS-KD-BK
Indicator Module
Keypad Module
Card Reader Module
Blank Module
49
Door Station Installation Guide
B. Cables
Routing Path 24AWG
(0.2mm²)
DS-KAD706 -
DS-KAD706-S
Transmission
Distance ≤ 60 m
DS-KAD706-S -
DS-KAD706-S
DS-KAD706-
DS-KD8003-
IME2
DS-KAD706-
DS-KH6320-
WTE2
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Table B-1 Wiring Cables
20AWG
(0.5mm²)
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
18AWG
(0.8mm²)
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
Transmission
Distance ≤ 60 m
RVV 4
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
Transmission
Distance ≤ 35 m
50
UD13575B
![](http://s3.manualzz.com/store/data/061207461_1-8f37693ead567176a2d916cc37953659-210x147.png)
Advertisement