Oase AquaMax Eco Classic 9000 C Operating Instructions Manual
The OASE AquaMax Eco Classic 12000 C is a reliable and efficient filter pump for garden ponds, combining high performance with energy efficiency. With a maximum flow rate of 12000 l/h and a maximum head of 5.5 m, this pump is perfect for operating filter systems, waterfalls, and watercourses. The pump's innovative design ensures quiet operation and low energy consumption, making it an excellent choice for eco-conscious pond owners.
Advertisement
Advertisement
Downloaded from http://www.watergardeningdirect.com
AquaMax
Eco Classic 9000 C / 12000 C / 18000 C
-
A
B
C
D
2
AMX0002
AMX0003
AMX0096
AMX0090
Downloaded from http://www.watergardeningdirect.com
E
F
-
AMX0089
AMX0094
3
-
G H
4
I
AMX0091 AMX0092
AMX0095
Downloaded from http://www.watergardeningdirect.com
J
- -
AMX0093
5
Downloaded from http://www.watergardeningdirect.com
- EN -
Translation of the original Operating Instructions
- EN -
EN
WARN ING
W ARNING
• This unit can be used by children aged 8
and above and
by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved.
• Do not allow children to play with the unit.
• Only allow children to carry out cleaning and user maintenance under supervision.
• Ensure that the unit is fused for a rated fault current of max.
30
mA by means of a fault current protection device.
• Only connect the unit if the electrical data of the unit and the power supply correspond. The unit data is to be found on the unit type plate, on the packaging or in this manual.
• Possible death or severe injury from electrocution! Before reaching into the water, disconnect all electrical units in the water from the mains.
• Only operate the unit if no persons are in the water.
• Do not use the unit if electrical cables or housings are damaged.
• A damaged connection cable cannot be replaced. Dispose of the unit.
17
Table of Contents
1
1.1
Information about these operating instructions
You made a good choice with the purchase of this product AquaMax Eco Classic 9000 C / 12000 C /
18000 C .
Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. Ensure that all work on and with this unit is only carried out in accordance with these instructions.
Adhere to the safety information for the correct and safe use of the unit.
Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new owner.
Warnings used in these instructions
The warning information is categorised by signal words, which indicate the extent of the hazard.
W A R N I N G
Indicates a possibly dangerous situation, which could lead to death or severe injuries, if not avoided.
N O T E
Indicates a possibly dangerous situation, which could lead to damage to property or the environment, if not avoided.
T I P
Useful tip.
18
Downloaded from http://www.watergardeningdirect.com
1.2 Cross-references used in these instructions
A reference to a figure, e.g. figure A.
→ Reference to another section.
- EN -
2
2.1
2.2
Safety information
Correct electrical installation
• Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
• A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regulations.
• For your own safety, please consult a qualified electrician.
• Route cables such that they are protected from damage and do not present a tripping hazard.
• Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash proof).
• Protect the plug connection from moisture.
• Only connect the unit to a correctly fitted socket.
Safe operation
• The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators (ICDs). Always keep magnets at least 0.2 m away from implanted devices.
• Never carry or pull the unit by the electrical cable.
• Never carry out technical changes to the unit.
• Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an authorised customer service point or, if in doubt, the manufacturer.
• Only use original spare parts and accessories for the unit.
3
3.1
3
4
5
6
Product Description
Overview
A
1
2
Description
Filter pump
Controller for regulating the speed of the filter pump
• Control via the OASE App "Easy Switch"
Retaining frame for mounting controller to the wall
Ground stake for mounting controller at ground level
Stepped hose adapter with ball joint, seal, coupling nut and hose clip
Stepped hose adapter with coupling nut and hose clip
19
3.2 Intended use
Only use the product described in this manual as follows:
• For pumping normal pond water for filter systems, waterfall systems and water course systems.
• Operate in accordance with instructions.
• Use for private purposes only.
The following restrictions apply to the unit:
• Do not use in swimming ponds.
• Never use the unit with fluids other than water.
• Never run the unit without water.
• Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
• Do not connect to the domestic water supply.
4 Installation and connection
The unit can be placed submerged or dry.
B
W A R N I N G
Death or serious injuries from hazardous electrical voltage due to operation of this unit in a swimming pond.
• Never operate this unit in a swimming pond.
4.1 Submerged installation of the pump
C
• Only install the unit below water level.
Place the unit horizontally on the ground ensuring its stable position.
How to proceed:
D
1. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
– This reduces pressure losses.
2. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
– Align the stepped hose adapter prior to tightening the union nut.
3. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
20
Downloaded from http://www.watergardeningdirect.com
4.2
- EN -
Install the unit at a dry place
E
• Swimming pond or pool that may be accessed by people.
– Install the unit at least 2 m away from the water.
• Do not expose the pump to direct sunlight.
How to proceed:
F
1. Remove screws.
– The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
– This reduces pressure losses.
5. Screw the stepped hose adapter including sealing ring onto the inlet.
6. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
– Align the stepped hose adapter prior to tightening the union nut.
7. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
– This reduces pressure losses.
8. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
– Align the stepped hose adapter prior to tightening the union nut.
9. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
4.3
4.4
4.5
Mounting the controller on the ground stake
How to proceed:
G
1. Fully insert the ground stake into the ground.
2. Slide the device onto the ground stake.
3. Check its stability.
Mounting the controller to the wall
How to proceed:
H
1. Affix the retaining frame using suitable screws.
2. Fit the device into the retaining frame.
– Ensure that the device is properly engaged in the retaining frame.
Connecting the controller
How to proceed:
I
1. Remove the protection cap from the unit.
2. Attach the connector and secure with the coupling nut.
– The connector and coupling must be clean and dry.
21
5 Commissioning/start-up
N O T E
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.
• Do not connect the unit to a dimmable power supply.
Switching on
The pump must be connected to the controller before the controller is switched on.
• First connect the controller to the mains supply, then switch on the pump at the controller.
Switching off
• Switch the pump off at the controller.
– Disconnect the controller from the mains before performing any work on the unit.
When started up, the pump automatically performs a pre-programmed self-test ( Environmental Function Control (EFC) ). The pump detects if it is running dry / blocked or submerged. The pump switches off automatically after approx. 90 seconds if it runs dry/is blocked. In the event of a malfunction, disconnect the power supply and “flood the pump” or remove the obstacle. Afterwards, the unit can be restarted.
6
6.1
Operation
Controller overview
Description
1 Four-digit LED display
2 “On/Off” button
3 Arrow keys
4 “Mode” button
5 LED wireless connection
Speed / %
Runtime / h
Power / W
RPM
ON
Error
22
AMX0087
Function
For displaying values
• Standard display is "Power / W" mode.
For switching the pump on or off
For increasing or decreasing rotation speed/power output
• For selecting the next mode
• For switching the wireless connection on/off
• The LED lights up when the wireless connection is switched on.
• The LED blinks when connected to the OASE App.
The respective LED lights up for the mode that is selected.
• The current mode appears in the display.
The LED lights up when the pump is switched on.
The LED lights up when an error occurs.
• The error code appears in the display.
Downloaded from http://www.watergardeningdirect.com
6.2 Operating functions
Switching the pump on/off
Proceed as follows
Press the button briefly to turn the pump on or off.
Information
–
- EN -
Increasing or decreasing rotation speed
Proceed as follows
Press the desired button several times or push continually in order to change the rotation speed in percent.
Information
• Adjustable range: 1 % … 100 %
• Increment: 1 %
• Adjustment is only possible in "Speed / %" or "Power / W” modes.
• The adjusted value is immediately adopted.
• By pressing a button the controller automatically switches to
"Speed / %” mode.
After 15 s without operation the controller automatically switches to "Power / W"mode.
Displaying current status values
Proceed as follows
Press the button briefly to select the next mode.
Information
"Runtime / h” mode
• Displays the total operating hours of the pump
• Displays up to 9999 operating hours: 0 to 9999
− Displayed increments: 1 hour
• Displays from 10000 to 99900 operating hours: 100H to 999H
− Displayed increments: 100 hours
− Example: 022H = 22 × 100 = 2200 operating hours
"Power / W” mode
• Displays the current power consumption of the pump in watts
− Tolerance: ±5 % of the max. power consumption.
"RPM" mode
• Displays the current speed of the pump in revolutions per minute
"Speed / %" mode
• Displays the current speed in percentage
− Display range: 1 to 100
After 15 s without operation the controller automatically switches to "Power / W"mode.
Switching the wireless connection on/off
Proceed as follows
Press and hold the button for longer than
10 s.
Information
• If boF appears in the display, the wireless connection is switched off.
• If bon appears in the display, the wireless connection is switched on.
− The LED in the display lights up when the wireless connection is switched on.
− The LED in the display blinks when connected to the
OASE App.
−
• When the unit is delivered, the wireless connection is switched on.
After 15 s without operation the controller automatically switches to "Power / W"mode.
23
Connecting the controller to the smart phone/tablet
The maximum distance for interference-free communication between the controller and smartphone/tablet depends on the transmission power of the smartphone/tablet. Brick walls, walls made of reinforced concrete, large metal objects or bushes and trees can dampen radio waves and decrease the distance.
Proceed as follows
1. Download and install the OASE App "Easy Switch" to the smartphone/tablet.
2. If you have not already done so, switch on the wireless connection at the controller.
3. Activate the Bluetooth feature on the smartphone/tablet. –
Information
The OASE App is available on iOS (App Store) and Android
(Play Store).
(→ Switching the wireless connection on/off )
4. Start the App "Easy Switch" .
5. Select your pump from the list.
After a brief search, a list of available products will appear.
An authentication code will be displayed on the controller for two minutes.
6. Enter the authentication code in the smartphone/tablet. Upon successful connection, the display will change to the operating instruction page for the pump.
• Now, the pump can be controlled via the smartphone/tablet.
• The LED in the controller display blinks.
7
7.1
Remedy of faults
Troubleshooting overview
Malfunction
Pump does not start
Pump does not transport fluid
Insufficient delivered quantity
Cause
No mains voltage
Faulty connection between pump and controller
Pump not switched on
Filter housing clogged
Excessively soiled water
Pump is set too low
The impeller unit is blocked
Filter housing clogged
Excessive loss in the supply lines
Pump is set too low
Pump switches off after operating briefly Excessively soiled water
The impeller unit is blocked
Pump has run dry.
Remedy
• Check the mains voltage.
• Check supply lines.
Check connection, and if needed reconnect
Switch the pump on at the controller
Clean strainer casings
Clean the pump. The pump automatically switches on again once the motor has cooled down.
Increase the rotation speed of the pump at the controller
Disconnect the power supply and remove obstacle. Then switch the pump on again.
Clean strainer casings
• Select larger hose diameter
• Adjust stepped hose adapter to hose diameter
• Reduce hose length to minimum necessary
• Avoid unnecessary connection elements
Increase the rotation speed of the pump at the controller
Clean the pump. The pump automatically switches on again once the motor has cooled down.
Disconnect the power supply and remove obstacle. Then switch the pump on again.
Flood the pump. Fully submerge the pump for operation in the pond.
24
Downloaded from http://www.watergardeningdirect.com
7.2
- EN -
Error messages
The error message automatically disappears after the error has been corrected.
Error message
Er1
Er2
Er3
Er4
Er5
Er6
Er7
Er8
Cause
No pump connected or connection to pump is faulty
Communication error between controller and pump
Excess temperature
Overcurrent
Pump blocked
Pump has run dry
Overvoltage
Undervoltage
Remedy
• Check that cable is connected correctly to pump
• Connect the pump to the controller
• Check that cable is connected correctly to pump.
• Connect the pump to the controller
• Check that impeller unit moves freely
− If the impeller unit is sluggish, the pump is requiring too much power
• The ambient temperature is too high
Check that impeller unit moves freely
• If the impeller unit is sluggish, the pump is requiring too much power
Check pump and remove obstacle
• Submerge pump in water
• For dry installation ensure adequate water supply
Connect the pump to the correct mains voltage
• The unit is not suitable for use with the existing mains voltage range
• Keep extension cable to the pump as short as possible.
− The voltage to the pump is too low due to the voltage drop in long cables.
• Use extension cable to the pump with greater conductor cross-section
− The voltage to the pump is too low due to the voltage drop in cables with too small of a conductor cross-section.
8 Maintenance and cleaning
T I P
Recommendation regarding cleaning:
• Clean the unit as required but at least twice a year.
• When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
• In the event of the filter housing capacity reducing, clean the unit under running water using a brush.
• Do not not use cleaning agents or chemical solutions.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
25
8.1 Cleaning the pump
How to proceed:
J
1. Screw off the stepped hose adapter.
2. Remove screws.
– The screws are used as transport protection and not required for operation.
3. Actuate the engagement hook and fold up the strainer top casing.
4. Remove pump.
5. Remove screws.
6. Remove the pump housing including its holding ring, sealing and impeller unit.
– Clean all components under running water using a soft brush, replace damage parts.
7. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed when closing the filter housing.
9 Wear parts
• Impeller unit
10 Spare parts
The use of original parts from OASE ensures continued safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare parts. www.oase.com/spareparts
11 Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
• Thoroughly clean the unit, check it for damage and replace any damaged parts.
• Store the pump submerged and in a frost-free environment.
• Protect open plug connections from moisture and dirt.
12 Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the regulations.
13 Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided for this purpose.
26
Downloaded from http://www.watergardeningdirect.com
14 Technical data
14.1 Unit data
Description
Connection voltage
Mains frequency
Power consumption
Pump protection type
Controller protection type
Connection Discharge port
Inlet port
Hose
Max. pump capacity
Max. pump head
Filter supply surface area
Max. particle size, coarse dirt particles
Max. immersion depth
Length of mains cable to controller
Length of mains cable to pump
Dimensions Length
Width
Height
Weight
V AC
Hz
W mm l/h m cm² mm m m m mm mm mm kg
9000°C
220 … 240
50/60
23 … 90
IP 68
IP 44
G1½
G1½
25/32/38
8800
4.5
810
8
4
2
10
280
230
140
4.4
AquaMax Eco Classic
12000°C
220 … 240
50/60
26 … 120
IP 68
IP 44
G2
G1½
25/32/38
12000
4.7
810
8
4
2
10
280
230
140
5.0
- EN -
18000°C
220 … 240
50/60
33 … 175
IP 68
IP 44
G2
G1½
25/32/38
17600
5.3
810
8
4
2
10
280
230
140
5.35
14.2 Water values
Type pH value
Hardness
Free chlorine
Chloride content
Overall dry residue
Temperature
Fresh water/Pond water
6.8 … 8.5
8 … 15 DH
<0.3 mg/l
<250 mg/l
<50 mg/l
+4 … +35°C
15 Symbols on the unit
Dust tight. Watertight to a depth of 4 m.
Dust protected. Protected against water splashed from all directions. Do not immerse.
Remove the unit at temperatures below zero (centigrade).
Possible danger for persons with pacemakers.
Protect from direct sunlight.
Do not dispose of with household waste.
Read the instructions for use.
27
Downloaded from http://www.watergardeningdirect.com

Download
Advertisement