Autonics TK4H, TK4L, TK4M, TK4N, TK4SP, TK4W Instruction Manual
Autonics TK4L, a compact and high-performance temperature controller, offers precise temperature control for various industrial applications. Its key capabilities include:
-
Input/Output Options: Supports thermocouple (TC), resistance temperature detector (RTD), voltage, and current inputs, providing flexibility for different sensor types. It features relay outputs for controlling heating or cooling systems and an alarm output for indicating process deviations. Additionally, it offers a communication output for data transmission and monitoring.
-
Control Modes: The TK4L provides versatile control modes, including ON/OFF, PID (Proportional-Integral-Derivative), and self-tuning PID, allowing users to optimize control strategies based on process requirements.
Advertisement
Advertisement
DRW170598AA Temperature / Process Controller ※1. In case of TK4N/SP Series, option control selection and digital input will be limited due to number of terminals. ※2. " S" represents SSR drive output support models which SSRP function (standard ON/OFF, cycle, phase) control are available. "C" represents selectable current and SSR drive output support models. ※3. Select "R" or "C" type in case of using heating&cooling control and "N" type in case of using standard control. ※4. Does not support in AC/DC voltage type model. ※5. Does not support in TK4N. ※6. The CT input model of TK4N is selectable only for standard model which has alarm output 1. ※7. The heating&cooling model of TK4N-1 has only alarm output 2. ※8. Only for TK4S-D , OUT2 output terminal is used as DI-2 input terminal. ※9. 11Pin socket (PG-11, PS-11(N)) for TK4SP: sold separately. ※Shaded descriptions are upgraded or added functions from the before TK Series. ※The above specifications are subject to change and some models may be discontinued without notice. ※Be sure to follow cautions written in the instruction manual, user manual and the technical descriptions (catalog, homepage). RS485(B-) RS485(A+) + + mA 10 3 4 - + - + mA 6 OUT1: 250VAC 3A 1a RESISTIVE LOAD - DI-1 Current DC0/4-20mA Load 500ΩMax. SSR 11VDC±2V 20mA Max. DI-1 3 - - 4 mA + DI-2 2 + 5 6 DI-2 + + - 7 SOURCE 100-240VAC 50/60Hz 8VA 24VAC 50/60Hz 8VA 24-48VDC 5W + mA - - RS485(A+) 14 15 OUT2: Relay 250VAC 3A 1a RESISTIVE LOAD 8 9 A 10 11 B 12 B' + 24 15 25 16 8 26 17 9 27 18 + + mA RTD TC - - SOURCE 100-240VAC 50/60Hz 8VA 24VAC 50/60Hz 8VA 24-48VDC 5W SENSOR Dimensions ●TK4H Series 94.8 3 1 13 2 14 6 48 + 7 - 8 + + 9 - - 10 + 6 OUT1: Relay 250VAC 3A 1a RESISTIVE LOAD 21 + + mA RTD TC SENSOR - - B' DI-1 DI-2 Transfer Output DC4-20mA + mA - Communication Output Current CT Transformer 0.0-50.0A 20 A 11 23 12 24 + + + mA B' RTD TC SENSOR - - 6 96 TK4N COVER (48×24mm) 44.6 (unit: mm) 64.5 1.5 ●TK4S/SP (48 × 48mm) Series ※Insert the unit into a panel, fasten the bracket by pushing with tools with a (-) driver. (-) driver 64.5 41.5 3 70 1.7 22.5 RHA-COVER (48×96mm, 96×48mm) 47.2 4 64 68.5 9.8 ●Panel cut-out ●Bracket TK4S, TK4SP Series 48.6 45 42 32.4 26.4 5 55 TK4M/W/H/L Series 31 20 46 15 21 12 23.9 10 56 13 13 86 ※TK4N COVER is accessory. 22 18 64.5 1.5 91.5 6 72 45.2 48.6 (-) driver 6 96 RMA-COVER (72×72mm) ●TK4M Series RSA-COVER (48×48mm) 48.4 91.5 ●TK4L Series TK4N Series ●Other Series 72.2 6 48 6.2 21.8 ●TK4SP Series 13 11 (+) driver + B Terminal cover (sold separately) 1. Measured value (PV) display part: RUN mode: It displays currently measured value (PV). Setting mode: It displays the parameter. 2. Set value (SV) display part: RUN mode: It displays the set value (SV). Setting mode: It displays the set value of the parameter. 3. Unit (℃/℉/%) indicator: It displays the unit set at display unit [UNIT] in parameter 3 group. (In case of TK4N, % is not supported) 4. Manual control indicator: It turns ON during manual controlling. 5. Multi SV indicator: One of SV1 to 3 lamps will be ON in case of selecting multi SV function. 6. Auto tuning indicator: It flashes by 1 sec. when executing auto tuning. 7. Alarm output (AL1, AL2) indicator: It turns ON when the alarm output is ON. 8. Control output (OUT1, OUT2) indicator: It turns ON when the control output is ON. ※During cycle/phase controlling in SSRP function model (TK4 - 4S ), when MV is over 5.0%, it turns ON. ※To use current ouput, when MV is 0.0% in manual control, it turns OFF. Otherwise, it always turns ON. When MV is over 3.0% in auto control, it turns ON and when MV is below 2.0%, it turns OFF. 9. key: It is used when switching auto control to manual control. ※TK4N/S/SP do not have the key. The key operates switching simultaneously. 10. key: It is used when entering parameter groups, returning to RUN mode, moving parameter, saving the set value. 11. , , keys: It is used when entering the set value changing mode and moving or changing up/down digit. 12. Digital input key: When pressing + keys for 3 sec. at the same time, it operates the function (RUN/STOP, alarm clear, auto tuning) set at digital input key [DI-K] in parameter 5 group. 13. PC loader port: It is the PC loader port for serial communication to set parameter and monitor with DAQMaster installed in PC. Use this for connecting SCM-US (USB/Serial converter, sold separately). ※Insert the unit into a panel, fasten the bolt with a (+) driver. A RS485(B-) B 12 ●TK4N (48 × 24mm) Series Current CT Transformer 0.0-50.0A 64.5 1.7 2 Installation - Communication Output RS485(A+) 22 3 10 mA 48 ●TK4S Series 48 9 Transfer Output DC4-20mA + RS485(B-) DI-2 18 19 1.5 Digital Input Non-contact, Contact Input 17 OUT2: Relay 250VAC 3A 1a RESISTIVE LOAD ●TK4W Series 64.5 DI-1 RS485(A+) DI-1 16 AL2 OUT: 250VAC 3A 1a RESISTIVE LOAD 6 DI-1 Digital Input Non-contact, Contact Input 15 AL1 OUT: 250VAC 3A 1a RESISTIVE LOAD 5 - mA 12 OUT1: Relay 250VAC 3A 1a RESISTIVE LOAD + mA 21 14 Current SSR DC0/4-20mA 11VDC±2V Load 500ΩMax. 20mA Max. AL2 OUT: 250VAC 3A 1a RESISTIVE LOAD 11 13 4 AL1 OUT: 250VAC 3A 1a RESISTIVE LOAD 10 20 23 3 1 6 8 7 4 5 + - 19 22 ●TK4H, TK4W, TK4L 7 13 RS485(B-) 16 OUT1: Communication Output Relay 17 Current 250VAC 3A 1a CT Transformer RESISTIVE LOAD 18 0.0-50.0A 48 + 6 SOURCE 100-240VAC 50/60Hz 8VA 24VAC 50/60Hz 8VA 24-48VDC 5W OUT2: Relay 250VAC 3A 1a RESISTIVE LOAD SSR 11VDC±2V 20mA Max. Transfer + mA Output DC4-20mA ●TK4N Series 5 Current DC0/4-20mA Load 500Ω Max. 1 + 4 - + 44.7 Digital Input Non-contact, Contact Input + - mA SOURCE 100-240VAC 50/60Hz 6VA 3 + mA AL2 OUT: 250VAC 0.5A 1a RESISTIVE LOAD Digital Input Current SSR Non-contact, DC0/4-20mA 11VDC±2V Contact Input Load 500Ω Max. 20mA Max. SOURCE 100-240VAC 50/60Hz 8VA 24VAC 50/60Hz 8VA 24-48VDC 5W ※ The input selection switch (TC, RTD/mV, V, mA) disappeared. Select input type [IN-T] in parameter 3 group. 12 5 Current DC0/4-20mA Load 500Ω Max. ●TK4S 11 AL1 OUT: 250VAC 3A 1a RESISTIVE LOAD AL2 OUT: 250VAC 3A 1a RESISTIVE LOAD 10 11 1 A RLA-COVER (96×96mm) D B 3 94 C (unit: mm) Size Model TK4N TK4S TK4S (P) TK4M TK4H TK4W TK4L A B C D 55 65 65 90 65 115 115 37 65 65 90 115 65 115 45+00.6 45+00.6 45+00.6 68+00.7 45+00.6 92+00.8 92+00.8 22.2+00.3 45+00.6 45+00.6 68+00.7 92+00.8 45+00.6 92+00.8 86 9999 (4-digit) TK 9 2 DI-2 DI-1 2 91.5 4 A 8 1 Current SSR DC0/4-20mA 11VDC±2V Load 500ΩMax. 20mA Max. Digital Input Non-contact, contact input 9 AL1 : Relay 250VAC 3A 1a RESISTIVE LOAD 13 Digit Item B 7 SSR 11VDC±2V 20mA Max. DI-1 + 1 2 DI-2 3 B A RTD SENSOR ●TK4M 3.3 Size ※1 24VAC 50/60Hz, 24-48VDC 100-240VAC 50/60Hz ※ Standard Alarm output 1+CT input 6 ※ 1 Heating&Cooling Alarm output 2 7 2 Standard Alarm output 1+Alarm output 2 Standard Alarm output 1+Digital input (DI-1, DI-2) N D Heating&Cooling Digital input (DI-1, DI-2) Standard Alarm output 1+Transmission output R Heating&Cooling Transmission output Standard Alarm output 1+RS485 communication output T Heating&Cooling RS485 communication output SP 1 Alarm output 1 1 Alarm output 1 2 Alarm output 1+Alarm output 2 S M R Alarm output 1+Transmission output W T Alarm output 1+RS485 communication output H A Alarm output 1+Alarm output 2+Transmission output L B Alarm output 1+Alarm output 2+RS485 communication output ※ D Alarm output 1+Alarm output 2+Digital input (DI-1, DI-2) 8 N DIN W48×H24mm ※9 SP DIN W48×H48mm (11pin plug type) S DIN W48×H48mm (terminal block type) M DIN W72×H72mm W DIN W96×H48mm H DIN W48×H96mm L DIN W96×H96mm ※5 TC SENSOR RTD B' OUT2/AL1 OUT: 250VAC 3A 1a RESISTIVE LOAD + + 8 4 Input/Output option 2 4 - Communication Output 37.5 40.5 Power supply R Relay output ※ S 4 SSR drive output (standard ON/OFF, cycle control, phase control) C Current output or SSR drive output selectable - mA Current Transformer 0.0-50.0A CT mA + TC + 96 OUT1 control ※ output 2 Heating& R Relay output Cooling C Current output or SSR drive output selectable ●TK4N + 7 91.5 Unit Description OUT2 control Standard N None ※Select in case of standard control (heating or cooling) ※ output 3 Transfer Output DC4-20mA + 16 1 4 R N <Forked> mA 36 TK 4 N At room temperature range (23℃±5℃) Thermocouple K, J, T, N, E type, below -100℃ / Thermocouple L, U, PLⅡ, Cu50Ω, DPt 50Ω: (PV ±0.3% or ±2℃, select the higher one) ±1-digit Thermocouple C, G, R, S type, below 200℃: (PV ±0.3% or ±3℃, select the higher one)±1-digit Thermocouple B type, below 400℃: there is no accuracy standards. Out of room temperature range RTD Cu50Ω, DPt50Ω: (PV ±0.5% or ±3℃, select the higher one) ±1-digit Thermocouple R, S, B, C, G type: (PV ±0.5% or ±5℃, select the higher one) ±1-digit Others, below -100℃: within ±5℃ In case of TK4SP Series, ±1℃ will be added to the degree standard. ※2: The weight includes packaging. The weight in parenthesis is for unit only. ※Environment resistance is rated at no freezing or condensation. - B' - 5 4 + 21.8 Ordering Information ※1: Max. 5.8mm - 45 1. W hen connecting the power input and relay output, use AWG 20 (0.50mm2) cable or over and tighten the terminal screw with a tightening torque of 0.74~0.90N m. When connecting the sensor input and communication cable without dedicated cable, use AWG 28~16 cable or over and tighten the terminal screw with a tightening torque of 0.74~0.90N m. Failure to follow this instruction may result in fire or malfunction due to contact failure. 2. U se the unit within the rated specifications. Failure to follow this instruction may result in fire or product damage. 3. U se dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in electric shock or fire. 4. D o not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in fire or explosion. 5. K eep metal chip, dust, and wire residue from flowing into the unit. Failure to follow this instruction may result in fire or product damage. Min. 3.0mm + - 44.8 Caution b + mA mA + 6 67.5 Warning 1. F ail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in fire, personal injury, or economic loss. 2. Install on a device panel to use. Failure to follow this instruction may result in electric shock. 3. D o not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in electric shock or fire. 4. C heck 'Connections' before wiring. Failure to follow this instruction may result in fire. 5. D o not disassemble or modify the unit. Failure to follow this instruction may result in electric shock or fire. a OUT2: SSR Current Relay 11VDC±2V DC0/4-20mA 250VAC 3A 1a RESISTIVE LOAD 20mA Max. Load 500ΩMax. - OUT1: Current SSR Relay DC0/4-20mA 11VDC±2V 250VAC 3A 1a Load 500ΩMax. 20mA Max. RESISTIVE LOAD <Round> 44.9 ※The symbols used on the product and instruction manual represent the following symbol represents caution due to special circumstances in which hazards may occur. Max. 5.8mm 22 ※Safety considerations are categorized as follows. Warning Failure to follow these instructions may result in serious injury or death. Caution Failure to follow these instructions may result in personal injury or product damage. Min. 3.0mm 36.3 ※Please observe all safety considerations for safe and proper product operation to avoid hazards. b b 3.5 Safety Considerations a a 11.6 Thank you for choosing our Autonics product. Please read the following safety considerations before use. ●TK4SP 7.9 INSTRUCTION MANUAL Connections ※Standard model has shaded terminals only. ※When the operation mode of heating&cooling OUT2 relay output model is heating or cooling control, the OUT2 is usable as alarm output 3 (except TK4N Series). ※When the operation mode of heating&cooling OUT2 current output model is heating or cooling control, the OUT2 is usable as transmission output 2. ※Use teminals of size specified below. 24 TK4 SERIES TK4N TK4SP TK4S TK4M TK4W TK4H TK4L 100-240VAC 50/60Hz 24VAC 50/60Hz, 24-48VDC 90 to 110% of rated voltage Max. 6VA Max. 8VA Max. 8VA (24VAC 50/60Hz), max. 5W (24-48VDC) 7-segment (PV: red, SV: green), other display part (green, yellow, red) LED method 4.5×7.2mm 7.0×14.0mm 9.5×20.0mm 8.5×17.0mm 7.0×14.6mm 11.0×22.0mm 3.5×5.8mm 5.0×10.0mm 7.5×15.0mm 6.0×12.0mm 6.0×12.0mm 7.0×14.0mm JPt 100Ω, DPt 100Ω, DPt 50Ω, Cu 100Ω, Cu 50Ω, Nikel 120Ω (6 types) K, J, E, T, L, N, U, R, S, B, C, G, PLII (13 types) ·Voltage: 0-100mVDC , 0-5VDC , 1-5VDC , 0-10VDC (4 types) ·Current: 0-20mA, 4-20mA (2 types) ※1 RTD ·At room temperature (23℃ ±5℃): (PV ±0.3% or ±1℃, select the higher one) ±1-digit ·Out of room temperature ranges: (PV ±0.5% or ±2℃, select the higher one) ±1-digit Thermcouple In case of TK4SP Series, ±1℃ will be added. Display ·At room temperature (23℃ ±5℃): ±0.3% F.S. ±1-digit accuracy Analog ·Out of room temperature ranges: ±0.5% F.S. ±1-digit CT input ±5% F.S. ±1-digit Relay OUT1, OUT2: 250VAC 3A 1a Control SSR Max. 11VDC ±2V 20mA output Current DC4-20mA or DC0-20mA selectable (resistance load: max. 500Ω) Alarm output Relay AL1, AL2: 250VAC 3A 1a ※TK4N AL2: 250VAC 0.5A, 1a (max. 125VA), TK4SP has only AL1 Transmission DC4-20mA (resistance load: max. 500Ω, output accuracy: ±0.3% F.S.) Option output Communication RS485 communication output (Modbus RTU) CT 0.0-50.0A (primary heater current reading range) ※CT ratio is 1/1000 (except TK4SP) ·Contact input: ON - max. 2kΩ, OFF - min. 90kΩ Option ·Non-contact input: ON - residual votage max. 1.0VDC , OFF - leakage current max. 0.1mA input Digital input ·Outflow current: approx. 0.5mA per input ※TK4S/M: 1 (TK4S-D : 2, TK4SP: none), TK4N/H/W/L: 2 (except TK4SP) Control Heating, Cooling ON/OFF, P, PI, PD, PID control mode method Heating&Cooling Hysteresis ·RTD/Thermcouples: 1 to 100℃/℉ (0.1 to 100.0℃/℉) variable ·Analog: 1 to 100-digit Proportional band (P) 0.1 to 999.9℃/℉ (0.1 to 999.9%) Integral time (I) 0 to 9999 sec Derivative time (D) 0 to 9999 sec ·Relay output, SSR drive output: 0.1 to 120.0 sec Control period (T) ·Current output+SSR drive output: 1.0 to 120.0 sec Manual reset value 0.0 to 100.0% Sampling period 50ms Dielectric strength 2,000VAC 50/60Hz for 1 min (between power source terminal and input terminal) Vibration 0.75mm amplitude at frequency of 5 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours ·OUT1/OUT2: min. 5,000,000 operations, Mechanical Relay ·AL1/AL2: min. 20,000,000 operations (TK4H/W/L: min. 5,000,000 operations) life cycle Electrical OUT1/OUT2, AL1/AL2: min. 100,000 operations Insulation resistance Over 100MΩ (at 500VDC megger) Noise immunity Square shaped noise by noise simulator (pulse width 1㎲) ±2kV R-phase, S-phase Memory retention Approx. 10 years (non-volatile semiconductor memory type) Environ Ambient temp. -10 to 50℃, storage: -20 to 60℃ -ment Ambient humi. 35 to 85%RH, storage: 35 to 85%RH Protection IP65 (front panel) ※TK4SP: IP50 (front panel) Double insulation or reinforced insulation Insulation type (mark: , dielectric strength between the measuring input part and the power part : 2kV) Approval Approx. 140g Approx. 130g Approx. 150g Approx. 210g Approx. 211g Approx. 294g ※2 Weight (approx. 70g) (approx. 85g) (approx. 105g) (approx. 140g) (approx. 141g) (approx. 198g) 28.8 High Accuracy PID Temperature Controller Specifications Series AC voltage Power supply AC/DC voltage Allowable voltage range AC voltage Power consumption AC/DC voltage Display method Character PV (W×H) size SV (W×H) RTD Input Thermcouple type Analog Flow Chart for Setting Group Parameter Mask Run mode Press any key among , , once. PASS ※1 When PW is valid 3 sec 2 sec PASS ※1 ※2 ※2 PASS ※1 When PW is valid PARU※3 H-MV Heating MV Monitoring PAR1 PAR2 Control output RUN/STOP[R-5] Set the set value SV Set user parameters in DAQMaster SV will be automatically saved after 5 sec. ※2 PAR3 Auto-tuning RUN/STOP[AT] 1.5 sec 1.5 sec C-MV Cooliing MV Monitoring PAR4 Input type[IN-T] PAR5 Alarm output1operation mode[AL-1] 1.5 sec PAR2 AT H-P C-P After applying mask PAR2 H-P H-I H-D 1.5 sec Heating proportional band[H-P] Sensor temperature unit[UNIT] Alarm output1 option[AL!T] Digital input key[DI-K] Heater current monitoring[CT-A] Cooling proportional band[C-P] Analog low-limit input value[L-RG] Alarm output1 hysteresis[A!HY] DI-1 input terminal function[DI-1] Alarm output1 low-limit set value[AL!L] Heating integral time[H-I] Analog high-limit input value[H-RG] Alarm1 N.O./N.C.[A!N] DI-2 input terminal function[DI-2] Alarm output1 high-limit set value[AL!H] Cooling integral time[C-I] Scaling decimal point[DOT] Alarm1 ON delay time[A!ON] Manual control, initial MV[ItMV] Alarm output2 low-limit set value[AL@L] Heating derivative time[H-D] Low-limit scale value[L-SC] Alarm1 OFF delay time[A!OF] Manual control, preset MV[PrMV] Alarm output2 high-limit set value[AL@H] Cooling derivative time[C-D] High-limit scale value[H-SC] Alarm output2 operation mode[AL-2] Sensor error, MV[ErMV] Alarm output3 low-limit set value[AL#L] Dead_overlap band[DB] Display unit[dUNT] Alarm output2 option[AL@T] Control stop, MV[StMV] Alarm output3 high-limit set value[AL#H] Manual reset[REST] Input correction[IN-B] Alarm output2 hysteresis[A@HY] Control stop, alarm output[StAL] SV-0 set value[SV-0] Heating hysteresis[hHYS] Input digital filter[MAvF] Alarm 2 N.O./N.C.[A@N] User level[USER] SV-1 set value[SV-1] Heating OFF offset[hOST] SV low-limit[L-SV] Alarm 2 ON delay time[A@ON] SV setting lock[LcSV] SV-2 set value[SV-2] Cooling hysteresis[cHYS] SV high-limit[H-SV] Alarm 2 OFF delay time[A@OF] Parameter 1group lock[LcP1] Cooling OFF offset[cOST] Control output operation mode[O-FT] Alarm output3 operation mode[AL-3] Parameter 2group lock[LcP2] MV low-limit[L-MV] Control type[C-MD] Alarm output3 option[AL#T] Parameter 3group lock[LcP3] MV high-limit[H-MV] Auto-tuning mode[AtT] Alarm output3 hysteresis[A#HY] Parameter 4group lock[LcP4] RAMP-up change rate[RAMU] OUT1 control output selection[OUT1] Alarm 3 N.O./N.C.[A#N] Parameter 5group lock[LcP5] RAMP-down change rate[RAMD] OUT1 SSR drive output type[O!SR] Alarm 3 ON delay time[A#ON] Password setting[PWD] RAMP time unit[rUNT] OUT1 current output range[O!MA] Alarm 3 OFF delay time[A#OF] OUT2 control output selection[OUT2] LBA time[LBaT] OUT2 current output range[O@MA] LBA band[LBaB] Heating control time[H-T] Analog trans. output 1 mode[AoM1] Cooling control time[C-T] Trans. output 1 low-limit value[FsL1] Trans. output 2 high-limit value[FsH2] Comm. address[ADRS] PAR1 AL!L AL!H Input Types and Range Decimal point Display 1 KCaH K (CA) 0.1 KCaL 1 JIcH J (IC) 0.1 JIcL 1 ECrH E (CR) 0.1 ECrL 1 TCcH T (CC) 0.1 TCcL B (PR) 1 B PR Thermocouple R (PR) 1 R PR S (PR) 1 S PR N (NN) 1 N NN C (TT)※1 1 C TT G (TT)※2 1 G TT 1 LIcH L (IC) 0.1 LIcL 1 UCcH U (CC) 0.1 UCcL Platinel II 1 PLII Cu 50Ω 0.1 CU 5 Cu 100Ω 0.1 CU10 1 JPtH JPt 100Ω 0.1 JPtL RTD DPt 50Ω 0.1 DPt5 1 DPtH DPt 100Ω 0.1 DPtL Nickel 120Ω 1 NI12 0-10V AV1 0-5V AV2 Voltage 1-5V AV3 Analog 0-100mV AMV1 0-20mA AMA1 Current 4-20mA AMA2 ※1: C (TT): Same temperature sensor as former W5 (TT) ※2: G (TT): Same temperature sesnor as former W (TT) Input range (℉) -328 to 2463 -199.9 to 999.9 -328 to 1472 -199.9 to 999.9 -328 to 1472 -199.9 to 999.9 -328 to 752 -199.9 to 752.0 32 to 3272 32 to 3182 32 to 3182 -328 to 2372 32 to 4172 32 to 4172 -328 to 1652 -199.9 to 999.9 -328 to 752 -199.9 to 752.0 32 to 2534 -199.9 to 392.0 -199.9 to 392.0 -328 to 1202 -199.9 to 999.9 -199.9 to 999.9 -328 to 1202 -199.9 to 999.9 -112 to 392 When power is supplied, whole display parts flash for 1 sec. Afterwards, model name and input sensor type will be flash twice and then in enters into RUN mode. ① Whole display part ② Model type display ③ Input type display twice ④ Run mode Set Value (SV) Setting , , You can set the temperature to control with keys. Set range is within SV low-limit value [L-SV] to SV high-limit value [H-SV]. Ex) In case of changing set temperature from 210℃ to 250℃ Press any key among ① ② , , in RUN mode to enter into SV setting mode. Last digit (100 digit) on SV display part flashes. ④ Press key to move digit. (100→ 10¹→ 10²→10³→ 100) Description OFF No alarm output DVCC Deviation high-limit alarm ]]DV Deviation low-limit alarm Deviation high/low-limit alarm CDV] Deviation high/low-limit reserve alarm PVCC Absolute value highlimit alarm OFF H OFF H ON ON If deviation between PV and SV as high-limit is higher than set SV PV PV SV value of deviation temperature, 100℃ 110℃ 90℃ 100℃ the alarm output will be ON. High deviation: Set as 10℃ High deviation: Set as -10℃ OFF H ON H OFF If deviation between PV and SV ON PV SV 90℃ 100℃ Low deviation: Set as 10℃ as low-limit is higher than set SV PV value of deviation temperature, 100℃ 110℃ Low deviation: Set as -10℃ the alarm output will be ON. If deviation between PV and SV as high/low-limit is higher than set value of deviation PV SV PV 90℃ 100℃ 120℃ temperature, the alarm output Low deviation : Set as 10℃ , High deviation : Set as 20℃ will be ON. ON H OFF H OFF H ON H OFF ON PV SV PV 90℃ 100℃ 120℃ Low deviation : Set as 10℃ , High deviation : Set as 20℃ OFF H ON OFF H If deviation between PV and SV as high/low-limit is lower than set value of deviation temperature, the alarm output will be OFF. ON If PV is higher than the absolute PV SV SV PV value, the output will be ON. 90℃ 100℃ 100℃ 110℃ Absolute-value: Set as 90℃ Absolute-value: Set as 110℃ ON H OFF ON H OFF ]]PV Absolute value low-limit alarm LBA Loop break alarm - It will be ON when it detects loop break. SBA Sensor break alarm It will be ON when it detects sensor disconnection. If PV is lower than the absoulte PV SV SV PV value, the output will be ON. 90℃ 100℃ 100℃ 110℃ Absolute-value: Set as 90℃ Absolute-value: Set as 110℃ Heater break HBA alarm ※H: Alarm output hysteresis[ A .HY] It will be ON when CT detects heater break. ●Alarm option Mode Name Description AL-A Standard alarm If it is an alarm condition, alarm output is ON. If it is a clear alarm condition, alarm output is OFF. AL-B Alarm latch Press key to save the set value. If there is no additional key operations in 3 sec, the changed SV is automatically saved. + + Press to reset all parameters in memory to default value. Set [INIT] parameter to 'YES' to reset all parameters. In case password function is on, it is required to enter valid password to reset parameters. Password is also reset. SV Parameter 0 Factory default PASS 0001 ●Parameter 1 group [ PAR1 ] Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default R-S SV-N CT-A AL!L RUN SV-0 )0 1550 AL!H AL@L AL@H AL#L 1550 1550 1550 1550 AL#H SV-0 SV-1 SV-2 1550 0000 0000 0000 SV-3 0000 Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default AT H-P C-P H-I C-I OFF 01)0 01)0 0000 0000 H-D C-D DB REST hHYS 0000 0000 0000 05)0 002 hOST cHYS cOST L-MV H-MV 000 002 000 `0)0 10)0 RAMU RAMD rUNT 000 000 MIN Alarm latch AL-D and standby sequence 1 Standby AL-E sequence 2 sequence 2 IN-T UNIT L-RG H-RG DOT L-SC KCaH ?C 0)00 1)00 )0 00)0 H-SC dUNT IN-B MAvF L-SV H-SV 10)0 ?/O 0000 00)1 -200 1350 O-FT C-MD AtT OUT1 HEAT H-C PID pP TUN1 CURR O!SR O!MA OUT2 O@MA H-T C-T STND 4-20 CURR 4-20 02)0 (Relay) 00@0 (SSR) ●Parameter 4 group [ PAR4 ] - AL-F and standby Parameter Reset A@HY Alarm operation Alarm latch -1999 to 9999 (Display point will be changed according to decimal point position.) A!HY - Standby , Press key to raise or lower the set value. IN-B Name AL-C sequence 1 ③ cHYS Mode Initial Display When Power ON Input range (℃) -200 to 1350 -199.9 to 999.9 -200 to 800 -199.9 to 800.0 -200 to 800 -199.9 to 800.0 -200 to 400 -199.9 to 400.0 0 to 1800 0 to 1750 0 to 1750 -200 to 1300 0 to 2300 0 to 2300 -200 to 900 -199.9 to 900.0 -200 to 400 -199.9 to 400.0 0 to 1390 -199.9 to 200.0 -199.9 to 200.0 -200 to 650 -199.9 to 650.0 -199.9 to 600.0 -200 to 650 -199.9 to 650.0 -80 to 200 hHYS Alarm Comm. write[COMW] Input type SV-0 Auto-tunning ]DVC 3 sec ●Password input parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default PAR2 Auto-tuning measures the control subject's thermal characteristics and thermal response rate, and then determines the necessary PID time constant. Application of the PID time constant realizes fast response and high precision temperature control. (when setting control type [C-MD] is set as PID, it is displayed.) Set [AT] parameter to [ON] in parameter 2 group to start auto-tuning. To stop auto-tuning, change the set as [OFF]. (It maintains P, I, D values of before auto-tuning.) If sensor break error [OPEN] occurs during auto-tuning, it stops this operation. If the measured temperature is over or below the input range, it operates continuously. During auto-tuning operation, whole parameters are only available to check. Comm. response waiting time[RSwT] 3 sec Parameter ●Parameter 2 group [ PAR2 ] The above is setting user parameter group in the DAQMaster with alarm output 1 low-limit value [AL!L], alarm output 1 high-limit value [AL!H], SV-0 set value [SV-0] parameter of parameter 1 group, heating hysteresis[hHYS], cooling hysteresis [cHYS] parameters of parameter 2 group, input correction [IN-B] parameter of parameter 3 group, alarm output 1 hysteresis [A!HY], alarm output 2 hysteresis [A@HY] parameters of parameter 4 group. Comm. parity bit[PRTY] Comm. stop bit[STP] Factory Default ●SV setting group [ SV ] ●Parameter 3 group [ PAR3 ] PARU Comm. speed[BPS] 3 sec C-D Run mode Trans. output 2 low-limit value[FsL2] 3 sec H-D This function is able to set the frequently used parameters to the user parameter group. You can quickly and easily set parameter settings. User parameter group can have up to 30 parameters in the integrated device management program (DAQMaster). For more information, refer to the DAQMaster user manual. Visit our website (www.autonics.com) to download the DAQmaster program and the user manual. Analog trans. output 2 mode[AoM2] 3 sec C-I ●Alarm operation Trans. output 1 high-limit value[FsH1] ※Hold the key over 2 sec in RUN mode to enter into setting mode. ※Hold the key for 1.5 sec while in setting mode to move to other parameter group. ※Hold the key over 3 sec while in setting mode to return to RUN mode. ※Press the key at the lowest level of parameter to move parameter group screen and press , key to move to other parameter group. ※If there is no additional key operation within 30 sec after entering into setting mode, it will be automatically returned to RUN mode and previous set value will be remained. ※The not-shaded parameters may not be displayed by other parameters setting, parameter mask setting. H-I User Parameter Group [ PARU] Setting Multi SV Number[SV-N] ※1. P ASS parameter will be displayed only when password is set. It is not displayed when purchasing the unit since default SV-3 set value[SV-3] password is set to 0000. If password is not valid, the screen will be shifted to password code required window. Press any key among , , to return to password entering window. Press key to return to RUN mode. In case you forget password, contact Autonics after checking password code. ※2. T K4N/S/SP do not have key. key replaces key. ※3. It is displayed when setting user parameter group in the integrated device management program (DAQMaster). Before applying mask The above is masking auto tuning [AT], cooling proportional band [C-P], cooling integral time [C-1], cooling derivative time [C-D] parameters in parameter 2 group. Multi SV[MtSV] 1.5 sec This function is able to hide unnecessary parameters to user environment or less frequently used parameters in parameter group. You can set this in the integrated device management program (DAQmaster). Masked parameters are not only displayed. The set value of masked parameters are applied. For more information, refer to the DAQMaster user manual. Visit our website (www.autonics.com) to download the DAQmaster program and the user manual. If it is an alarm condition, alarm output is ON and maintains ON status. First alarm condition is ignored and from second alarm condition, standard alarm operates. When power is supplied and it is an alarm condition, this first alarm condition is ignored and from the second alarm condition, standard alarm operates. If it is an alarm condition, it operates both alarm latch and standby sequence. When power is supplied and it is an alarm condition, this first alarm condition is ignored and from the second 1alarm condition, alarm latch operates. First alarm condition is ignored and from second alarm condition, standard alarm operates. When re-applied standby sequence and if it is alarm condition, alarm output does not turn ON. After clearing alarm condition, standard alarm operates. Basic operation is same as alarm latch and standby sequence1. It operates not only by power ON/OFF, but also alarm set value, or alarm option changing. When reapplied standby sequence and if it is alarm condition, alarm output does not turn ON. After clearing alarm condition, alarm latch operates. ※Condition of re-applied standby sequence for standby sequence 1, alarm latch and standby sequence 1: Power ON Condition of re-applied standby sequence for standby sequence 2, alarm latch and standby sequence 2: Power ON, changing set temperature, alarm temperature [AL1, AL2] or alarm operation [AL-1, AL-2], switching STOP mode to RUN mode. Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default AL-1 AL!T A!HY A!N A!ON A!OF AL-2 AL@T A@HY DVCC AL-A 001 NO 0000 0000 ]]DV AL-A 001 A@N A@ON A@OF AL-3 AL#T A#HY A#N A#ON A#OF NO 0000 0000 OFF AL-A 001 NO 0000 0000 LBaT LBaB AoM1 FsL1 FsH1 AoM2 FsL2 FsH2 ADRS 0000 002 PV -200 1350 PV -200 1350 01 BPS PRTY STP RSWT COMW 96 NONE 2 20 EnA ●Parameter 5 group [ PAR5 ] Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default MtSV DI-K DI-1 DI-2 ItMV 1 STOP OFF OFF AUTO PrMV ErMV StMV StAL USER 00)0 00)0 00)0 CONT STND LcSV LcP1 LcP2 LcP3 LcP4 OFF OFF OFF OFF OFF LcPS PWD OFF 0000 ※Shaded parameters are for the heating&cooling model. User Manual For the detail information and instructions, please refer to user manual and user manual for communication, and be sure to follow cautions written in the technical descriptions (catalog, homepage). Visit our homepage (www.autonics.com) to download manuals. Comprehensive Device Management Program[DAQMaster] DAQMaster is a comprehensive device management software for setting parameters and monitoring processes. DAQMaster can be downloaded from our website at www.autonics.com. Item System Operations Memory Hard disk VGA Others Minimum specifications IBM PC compatible computer with Pentium Ⅲ or above Windows 98/NT/XP/Vista/7/8/10 256MB+ 1GB+ of available hard disk space Resolution: 1024×768 or higher RS232C serial port (9-pin), USB port Cautions during Use 1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents. 2. Check the polarity of the terminals before wiring the temperature sensor. For RTD temperature sensor, wire it as 3-wire type, using cables in same thickness and length. For thermocouple (CT) temperature sensor, use the designated compensation wire for extending wire. 3. Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise. 4. Do not apply excessive power when connecting or disconnecting the connectors of the product. 5. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power. 6. Do not use the unit for other purpose (e.g. voltmeter, ammeter), but temperature controller. 7. When changing the input sensor, turn off the power first before changing. After changing the input sensor, modify the value of the corresponding parameter. 8. 24VAC, 24-48VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device. 9. Do not overlapping communication line and power line. Use twisted pair wire for communication line and connect ferrite bead at each end of line to reduce the effect of external noise. 10. Make a required space around the unit for radiation of heat. For accurate temperature measurement, warm up the unit over 20 min after turning on the power. 11. Make sure that power supply voltage reaches to the rated voltage within 2 sec after supplying power. 12. Do not wire to terminals which are not used. 13. This unit may be used in the following environments. ①Indoors (in the environment condition rated in 'Specifications') ②Altitude max. 2,000m ③Pollution degree 2 ④Installation category II Major Products Photoelectric Sensors Temperature Controllers Fiber Optic Sensors Temperature/Humidity Transducers Door Sensors SSRs/Power Controllers Door Side Sensors Counters Area Sensors Timers Proximity Sensors Panel Meters Pressure Sensors Tachometer/Pulse (Rate) Meters Rotary Encoders Display Units Connector/Sockets Sensor Controllers Switching Mode Power Supplies Control Switches/Lamps/Buzzers I/O Terminal Blocks & Cables Stepper Motors/Drivers/Motion Controllers Graphic/Logic Panels Field Network Devices Laser Marking System (Fiber, CO₂, Nd: YAG) Laser Welding/Cutting System http://www.autonics.com HEADQUARTERS: 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan, South Korea, 48002 TEL: 82-51-519-3232 E-mail: [email protected] DRW170598AA ">
Advertisement
Key features
- PID control algorithm for precise temperature regulation
- Universal input compatibility for thermocouples, RTDs, and voltage/current signals
- Multiple control modes including ON/OFF, PID, and ramp/soak
- Digital input and output for remote control and monitoring
- Alarm functions for over-temperature and other process deviations
- Modbus RTU communication for integration with industrial networks
- Panel mount design for easy installation in control panels