BWT AQUADIAL softlife 10 Bio Fitting And Operating Instructions
BWT AQUADIAL softlife 10 Bio is a domestic water softener designed to soften or partially soften domestic water. It features a microprocessor controller, blending valve, softening column with ion exchange resin, and various connections for water inlet, outlet, and drainage. The device comes with a hardness tester, drain hose, and fixing material. It offers adjustable settings for water hardness, regeneration time, and salt dosage. Additionally, it includes a salt alarm and the option to use care cubes or block salt.
Advertisement
Advertisement
Fitting and operating instructions EN
Einbau- und Bedienungsanleitung D
Important notice: Always keep the fitting and operating instructions close at hand to avoid any mistakes and before carrying out any work on the device you should read the fitting and operating instructions carefully and follow them. While our data sheets and brochures should provide advice to the best of our knowledge, the content thereof is not legally binding. deliquatinim acin henis at.
Wichtige Hinweise: Um Fehler zu vermeiden, ist die Einbau- und Bedienungsanleitung stets griffbereit aufzubewahren, vor der Ausführung von
Arbeiten am Gerät vollständig durchzulesen und zu beachten. Unsere
Merkblätter und Druckschriften sollen nach bestem Wissen beraten, der
Inhalt ist jedoch ohne Rechtsverbindlichkeit. Im Übrigen gelten unsere allgemeinen Geschäftsbedingungen.
BWT AQUADIAL softlife
Domestic water softener
10, 15, 20, 25
Weichwasseranlage
10, 15, 20, 25
Table of contents
1. Introduction ........................................................................................................................................ 4
1.1 General comments ............................................................................................................... 4
1.2 Manufactor .......................................................................................................................... 4
1.3 Safety instructions ................................................................................................................. 4
1.4 Intended use ........................................................................................................................ 4
1.5 Scope of delivery ................................................................................................................. 5
2. Quick Operation ................................................................................................................................ 6
2.1 Display and control elements ................................................................................................. 6
2.2 Standard factory settings ....................................................................................................... 6
2.3 Programming procedure ........................................................................................................ 7
3. Installation ......................................................................................................................................... 8
3.1 Installation requirements ........................................................................................................ 8
3.2 Initial commissioning ............................................................................................................ 8
3.3 Installation and operation considerations ................................................................................ 9
3.4 Installation Layout ............................................................................................................... 11
3.5 Technical overview of device: .............................................................................................. 12
3.6 Installing your softener ........................................................................................................ 13
4. Operation ........................................................................................................................................ 14
4.1 Function ............................................................................................................................ 14
4.2 Operation ......................................................................................................................... 14
4.3 Setting the hardness of blended water .................................................................................. 16
5. Maintenance .................................................................................................................................... 16
5.1 Maintenance work ............................................................................................................. 16
5.2 Operator responsibilities ..................................................................................................... 16
5.3 Maintenance & wearing parts ............................................................................................. 16
5.4 Disposal ............................................................................................................................ 16
6. Fault finding ..................................................................................................................................... 17
6.1 Trouble shooting Guide ....................................................................................................... 17
7. Technical data .................................................................................................................................. 19
7.1 BWT AQUADIAL softlife 10 / 10 Bio* ................................................................................. 19
7.2 BWT AQUADIAL softlife 15 / 15 Bio* ................................................................................. 20
7.3 BWT AQUADIAL softlife 20 / 20 Bio* ................................................................................. 21
7.4 BWT AQUADIAL softlife 25 / 25 Bio* ................................................................................. 22
EN
EN
1. Introduction
1.1 General comments
Please read this manual carefully and famliarise yourself with the operating instructions before using this equipment.
Models covered by this manual:
BWT AQUADIAL for the device types:
- softlife 10 / 10 Bio
- softlife 15 / 15 Bio
- softlife 20 / 20 Bio
- softlife 25 / 25 Bio
The local standards as well as technical specifications have to be observed.
The operating instructions must be read in conjunction with any national regulations concerning accident prevention and environmental protection.
Prior to putting the device into operation, read the operating instructions completely and thoroughly.
Please keep this manual close to hand for quick reference to the unit’s operation.
The device shall only be used for its intended purpose, in line with the operating instructions and only in the environment to which intended.
Note: Never exceed the defined maintenance and service intervals.
1.3 Safety instructions
Danger caused by electric current or voltage!
Always consult a qualified electrician when working on places denoted by
this symbol.
The complete power supply unit must be replaced in the event of damage to the mains cable.
Warning:
Do not use any aggressive cleaning agents!
If a power failure occurs when regeneration waste water and overflow are being drained into a sump, flooding may occur.
Please observe:
Use only trained or instructed staff.
Stipulate clear staff responsibilities for operation, set-up, maintenance and repair work.
Please observe:
NEVER operate the device with the housing covers removed.
Note:
If needed use protective clothing.
1.2 Manufactor
BWT UK Ltd.
Coronation Road, BWT House
High Wycombe
Buckinghamshire, HP12, 3SU
Phone: +44 / 1494 / 838 100
Fax: +44 / 1494 / 838 101
E-Mail: [email protected]
Note:
Additional information for the operator.
1.4 Intended use
The domestic application AQUADIAL softlife is designed for softening or partially softening domestic water (in accordance with the relevant regulations.)
All other use is strictly forbidden and your own responsibility.
4
1.5 Scope of delivery
BWT AQUADIAL softlife water softer with:
Standard delivery:
1. Multi-way control valve with microprocessor controller
2. Blending valve
3. Softening column with ion exchange resin
4. Softened water outlet
5. Hard water inlet
6. Drain water
7. Overflow connection
8. Mains plug power supply connection
9. Operating manual
10. Hose clamp connection
11. 2 m drain water hose
12. Cover with short user instructions
13. AQUATEST hardness tester
Please open the cover (12), (See page 9):
14. Salt storage
15. Cabinet
16. Fixing material (See page 9)
17. Rating plate and serial number (See page 9)
Additional delivery:
18. Non-return valve BSP: ¾” (DN: 20/20)
9
12
8
18
13
10
11
6
7
3
2
5
12
14
15
4
5
1
EN
EN
2. Quick Operation
2.1 Display and control elements
Note:
In the programming mode the respective
>target value< flash.
The display shows: the current time and the remaining
capacity in %
[UP] [DOWN]
= Moves cursor changes entries
[SET]
= Confirms entries
[RECHARGE]
= Programming recharge tonight
2.2 Standard factory settings
Operating range:
Regeneration time: depends on model free input at RECHARGE TONIGHT
Hardness of drinking water / capacity: 300 ppm, 1566 litres for 10 litre model
BWT AQUADIAL softlife
Display
Operating range
Recharge tonight
Salt alarm
Salt setting - care cubes (CC)
Salt setting - block salt (BS)
Standard
Yes
UK/EU
Yes
No
UK/EU
UK only
BIO
Yes
UK/EU
Yes
No
UK/EU
UK only
UK
Yes
EU
Yes
1.7 ... 5.0 bar 1.0 ... 8.0 bar
Yes Yes
OPTION
Yes
Yes
OPTION
Yes
No
6
2.3 Programming procedure 2. Setting the water hardness (see Fig. 2)
The display default is 300 ppm (typical hardness level) which indicates a setting suitable for hard water with a value of 300 parts per million of hardness minerals. Use the keys [UP] [DOWN] keys to adjust the setting to match that of the one you obtained / identified earlier. See page 6 for details.
EN
1. Setting the time of day (see Fig. 1)
The first two digits (00) of the display will flash prompting the installer to set the time.
Pressing the [SET] set key once enters the hardness and moves the display to Set Recharge Time Mode.
The time is adjusted by using the [UP], [DOWN] keys.
Pressing the [SET] key enters the hours.
The minutes are set by using the [UP], [DOWN] keys.
3. Setting the recharge time (see Fig. 3)
To operate effectively, your water softener needs to regenerate periodically (dependent on the hardness of the supply and amount of water used). The default time of day when this is to occur is 2.00am. To alter this setting use the [UP] [DOWN] keys.
Pressing the [SET] key once enters the minutes and moves the display into the Set Hardness mode.
Pressing the [SET] key once enters the recharge time and moves the display into Set Salt Type
Mode.
This option is only available on certain models - not standard
7
EN
3. Installation
3.1 Installation requirements
National guidelines and regulations:
Observe all applicable installation regulations, general guidelines, hygiene requirements, and technical specifications. The hard water to be fed into the unit must always meet the specifications of the national Drinking Water Ordinance or EU Directive
98/83/EC. The total dissolved iron and manganese may not exceed 0.1 mg/l. The hard water to be fed into the unit must always be free of air bubbles.
Frost protection and ambient temperature:
The installation site must be free of frost and kept free of chemicals, paint, solvents and fumes.
The ambient temperature should not exceed 40°C , even before the machine is started. Please avoid direct heat sources, e.g. radiators and exposure to sunlight.
General safety:
The rated mains power (see technical data) and the requisite inlet water pressure must be present at all times. No protection against a lack of water is provided. This must be installed on-site if required.
Overpressure and fluctuation protection:
Attention: Water pressure must never exceed the unit‘s maximum of 5.0 bar UK, 8.0 bar EU.
If the network water-pressure is higher than 4.0 bar
UK, 6.0 bar EU (or you are unsure about pressure), a pressure reducer (pressure reducing valve) must be installed upstream of the unit.
During pressure fuctuations or surges, the sum of the pressure surge and the standing pressure is not to exceed the nominal pressure.
Electrical interference:
The emission of interference (voltage peaks, high-frequency electromagnetic fields, interference voltages, voltage fuctuations…) by the surrounding electrical systems may not exceed the maximum values specified in EN 61000-6-3.
Data analysis of the hard water in your area:
Continuous operation of the water softener with water containing chlorine or chlorine dioxide is possible if the concentration of free chlorine/chlorine dioxide does not exceed 0.5 mg/l.
The type of pre-treatment must be determined individually.
Principle of intelligent regeneration:
The unit should be sized according your current water consuption. If water consumption is reduced, e.g. during holidays, a shut-off device must be fully opened for at least 5 minutes before water can be used again.
8
Inlet- and outlet connections:
When installing the unit, select a location where the unit can easily be connected to the water supply network. A connection to the waste water system (at least DN 50) , a floor drain and a separate mains socket (see technical data) must be nearby.
Overflow hose connection:
A suitable overflow hose connection is required to remove the waste water.
Preconditions for the hydraulic installation:
Observe the hydraulic and electrical requirements for installation for first commission. (see “chapter 5”)
Exclusion of warranty:
Non-compliance with the installation conditions and the operator responsibilities voids the warranty.
Guarantee:
In the event of a malfunction of the unit during the guarantee period, please contact your after-sales service department and quote the model type and the production number (see technical data or the rating plate on unit).
Note: Only your local after-sales service staff may perform any works under the guarantee.
Any work performed by a third party must be directly commissioned by your after-sales service.
3.2 Initial commissioning for professional installation by a qualified fitter.
- Has all packaging material (16) been removed from the brine cabinet?
- Is there a protective filter upstream from the unit in the immediate vicinity?
- Is the water and power supply to the unit continuous (network pressure of at least 1.7 bar UK
/1 bar EU)
- Have you opened the pressure reducing valve to the limit stop ?
- Have the water hoses been properly connected?
- (Observe the flow direction arrows and hard water inlet at the non-return valve of the unit).
- Have the drain water hose and the overflow been routed separately to the waste water system and connected? (See Installation)
- Have you informed the operator of the inspection schedule? (Check supply of salt and hardness of blended water at least every two months)
- Have you informed the operator of the maintenance schedule? (Tasks in accordance with manufacturer’s instructions. Interval annually, every 6 months with communal units)
Please check connections and pipeline junctions for leaks.
Handing over the unit to the operator:
If there is a delay between the installation/startup of the unit and transfer to the operator, a manual regeneration must be performed. The operator must be told how the unit works as well as how to operate and inspect it. Ensure that the operator receives the installation and operating manual.
16
15
17
Please open the cover (12)
14. Salt storage
15. Cabinet
16. Fixing material
17. Rating plate and serial numberin
14
3.3 Installation and operation considerations
1. Before you begin
The installation of your new water softener is relatively straightforward. However, we would recommend that either a qualified plumber or a person with relevant plumbing experience carries out the installation.
Before embarking on the installation, please ensure you have familiarised yourself with both these instructions and the components required to complete the installation.
EN
2. Positioning the water softener
Please measure your water softener to ensure that it will fit into the area you are placing the unit into.
PLEASE remember to include additional space for connecting pipe work in your calculations along with the regular access that is needed for topping the unit up with salt and future service.
Where possible, the distance of both the incoming water supply and nearest drain should be kept to a minimum. Two metres is an ideal distance, however, longer distances are permissible, dependant on the incoming water pressure.
Please remember the weight of your new water softener will considerably increase once installed and filled with salt. Therefore, please ensure your chosen location is strong enough to support an approximate total weight of (see table). Your new water softener has been designed to operate efficiently and effectively with an incoming water pressure of between
1.7 to 5.0 bar UK, 1.0 to 8.0 bar EU. If your water supply is likely to fall outside these limits, then we would recommend that a booster pump or pressure reducing valve should be fitted respectively.
Operating pressure
3.5 bar UK /
4.5 bar EU
If pressure more than:
5.0 bar UK / 8.0 bar
EU install pressure reducing valve
Do not operate with a pressure less than:
1.7 bar UK / 1.0 bar EU
12
Important - Never install the water softener where it, or its connections (including the drain overflow lines) will be subject to temperatures under 0°C or above 40°C.
If you are planning to install the water softener above ground level e.g. In the loft,the following instructions should be strictly adhered to.
9
EN
3. Loft installation
The water softener should be installed within a container of not less than 100 litre capacity, to which there should be connected an overflow pipe of not less than 20 mm diameter. The overflow should be connected at the bottom of the container and not less than 15 0mm below the height of any electrical components mounted on the water softener. It is recommended that an anti vacuum valve be fitted to the inlet pipework supplying the water softener.
4. Plumbing systems
There are several types of plumbing systems in common use:
For 15 mm pipework (e.g.Static Head systems)
The water softener can be supplied optionally with a high flow installation kit and flexible high flow hoses suitable for 22mm pipework, for 15 mm pipework use the reducing bushes supplied with the kit, (see diagram on page 11).
5. Backflow prevention device
When fitted to the supply feeding a single dwelling, a check valve complying with national regulations must be fitted on the cold water feed prior to the installation. All other types of installation require the fitting of a double check valve.
6. Drinking water
Your water softener installation must include at least one drinking water tap that is not fed by the water softener.
In case of low sodium diet follow the local “department of health‘s“ advice concerning the use of softened water for drinking.
Note: Water that is used for mixing powdered milk for babies must only be taken from an unsoftened mains tap as some powdered milks and softened water both contain sodium for which young babies have a limited tolerance.rer. Original spare parts and accessories authorized by the manufacturer guarantee operational safety. Using non-authorized parts may void any liability on the part of the manufacturer in case of consequential damage.
10
3.4 Installation Layout
To rising
main
Inlet from
mains
I.
Outlet from softener
N.
Key to the diagram:
A.
Non return valve
B.
Pressure reducing valve (where required)
C.
Inlet valve ¾ “
D.
Bypass valve
E.
Outlet valve ¾ “
G. Brine storage cabinet
Waste water hose
H.
Fixing clip
C. Inlet
M.
Rising Main
Valve Head
L.
E. Outlet
Inlet to softener
Key to the diagram:
H.
Fixing clip
I.
Waste water hose
J.
Drainage
K.
Flexible hose, Overflow
L.
Control valve (green)
M.
Servo-motor for valve positioning
N.
Distance device & ceiling of room
O.
Overflow connection ½“
P.
Hose barb
20 mm
O.
Overflow *
G.
Brine storage
Cabinet
F . Mains stop valve
Water softener
P.
J.
Drainage (
K. Overflow flexible hose
* Existing or new “Trapped“ stand pipe or to external drainage)
Observe a minimum distance to the ceiling (N) of 0.5 m.
11
EN
EN
3.5 Technical overview of device:
C. Inlet connection (feed water) for flexible hose, with thread ¾“
E. Outlet connection (softened water) for flexible hose, with thread ¾“
G1. Brine storage cabinet
G2. Connection to brine
O. Overflow connection
L. Control valve
M. Servo motor
I. Waste water connection
salt filling
internal connection
for flexible hose, threadless ½ “
flow regulation
for control valve
external drainage of waste water
M.
I.
C.
I.
E.
L.
G2.
G1.
O.
C.
E.
L.
Attention: Pipework sized min. DN50. Use only the flexible hoses included in the delivery.
Ensure a correct sealing and setting of all pipes before first commissioning.
Attention: To comply with good plumbing practice the external waste-water-drainage must have a minimum space of air: 20mm (according to guideline EN 14743).
Attention: Drainage from the overflow of the brine tank, Connections between the channel and two flexible hoses (according to standard EN 3131).
Protection of device: To increase the lifetime of your softener ensure it is kept in a clean, dry place with an ambient temperature between 5 and 40 °C. Do not mention damage to resin or components.
12
3.6 Installing your softener
1. Positioning the water softener
It is very important to establish the water pressure before installing the water softener. If the water pressure is low then the water softener may not operate effectively. If it is too high, then components inside the unit may be damaged.
Water pressure should be tested with a gauge at the kitchen tap or outside tap. It should be noted that water pressure can increase at periods of low water usage e.g. overnight.
If therefore, the daytime pressure exceeds 5.0 bar UK, 8.0 bar EU or if you are unsure about pressure, then a pressure reducing valve should be fitted.
Where the pressure is less than 1.7 bar UK, 1.0 bar
EU a booster pump may be required.
2. Inlet and outlet connections
With the bypass valve open and the inlet / outlet valves closed the unit can be connected to the plumbing system. Arrows on the inlet and outlet piping from the valve will confirm the direction of flow.
Connections can be made with either conventional copper tube and fittings or the high flow flexible hoses supplied, ensure hoses are not kinked as this may restrict flow.
3. Drain connection
Push the flexible drain hose onto the barbed connector (Drain) as shown on page 7 and secure with the clip provided. Run the drain hose to a stand pipe or to a drain. The air gap needs to be at least 20 mm . Softened water will have no adverse effect on a septic tank. You can extend the drain up to 9m if you have sufficient pressure (greater than 3 bar ). The drain hose must not be kinked or restricted in any way as this will cause an overflow from the brine cabinet.
Frost protection
If the drain hose or connecting pipework is likely to be subject to temperatures below 0°C it must be protected to prevent freezing. Failure to observe this precaution could lead to the water softener overflowing.
Raising the drain hose
If you have a water pressure of 3 bar or more, you can raise the drain to a maximum of 3 metres above the valve head.
4. Overflow connections
The hose barb overflow pipe (not supplied with the softener) should be connected to the push fit elbow at the rear of the cabinet (see page 9).
Run the pipe downhill to the drainage. Take care that the overflow does not discharge where damage could occur.
If the water softener is fitted in a cellar or basement, the overflow can be run to a storage tank. Do not elevate the overflow hose.
Note: Do not use jointing cement on the fitting.
EN
5. Electrical connections
For added safety, peace of mind and ease of installation, your water softener is powered by low voltage via a plug in transformer. This transformer must be connected to a switched socket.
Attention: Plug the transformer into the socket with the switch in the OFF-position .
6. Filling the brine cabinet, salt- usage and alarm
Now place the water softener salt in the brine cabinet. Use the care cubes (tablet salt) or block salt
(UK), from your local dealer.
Notes on salt usage: Your water softener will only perform effectively if there is salt in the brine cabinet during the regeneration process.
It is therefore essential that the salt level does not fall lower than 150mm in depth when measured from the base of the brine cabinet. N.B. The softener requires no priming, add no water to the brine tank.
During regeneration, salt will not enter your water system as the salt used in the regeneration process is rinsed safely away to drain.
Salt alarm is optional - not standard on most models.
Depending on your model your water softener may be equipped with a low salt alarm, this monitors your salt usage and sounds an audible alarm while displaying the low salt error code “SALt“ when your salt levels falls to the minimum level. To reset the salt alarm fill the system with salt and press the SET-key.
7. Blending control
All machines are factory set to producewater that is soft. Note: If you prefer water which is less soft, turn the blending knob on the left side of the valve anticlockwise until the water meets your requirements.
8. Testing for the water hardness in your area
Water hardness can vary from one location to another. To determine the hardness of the water feeding your water softener (unsoftened supply) use the hardness test kit supplied.
- Fill the test bottle supplied to the fill line with
water from a hard water tap.
- Add the tablets to the solution one tablet at a time.
13
EN
- Shake the bottle in between and keep adding tablets to the water until the solution turns from wine red to blue, record the number of tablets as you go.
- Using the data table supplied with your kit, match up the number of tablets with the hardness. You will need this figure when programming your water softener in the next section of this manual.
9. Switching on for the first time
- Check that the inlet hoses and outlet hoses or couplings are properly connected i.e. inlet-toinlet, outlet-to-outlet.
The by-pass arrangement (see page 09) should be in the open position in example:
- the inlet and outlet valves closed (E), (C)
- Check that the by-pass valve (D) open
- Check that the mains stop valve (F) open.
- Check that the Brine Cabinet (G) contains salt.
- Check that the water softener is connected to the drain (H) and the overflow pipe is be linked to each other connected .
Note: The drain and overflow must not be linked to each other.
- Gently open the inlet valve (C) so that water flows into the resin vessel.
- Turn ON the power, you will hear the valve move quietly into the start position. When the positioning process has been completed (which can take up to 5 minutes) you will hear the movement stop, the valve has now reached its start position in preparation for the programming procedure.
- Close the by-pass valve (D).
- Gently open the outlet valve (E).
- Check for leaks, take corrective action to stop leaks if required.
- Your water softener is now on line and you may start the valve programming procedure set out in the next section of this manual. connect jack plug here
Lift off this cover and connect the jack plug of the lead to the control box behind the front panel
4. Operation
4.1 Function
Capacity requirement-dependent of the unit controller:
The unit operates according to the principle of intelligent regeneration. The average capacity level of each model is preset and updates automatically to the actual consumption within 14 days.
The presetting is appropriate for the most common applications. It is not necessary to adjust the unit for individual requirements.
Intelligent quantity-dependent regeneration
When the unit is started, the available supply of softened water is programmed (depending on the hardness of the water).
At a user-defined time (e.g. at night), the unit checks whether the remaining supply of softened water is sufficient for the following day. If this is not the case, the softening column is regenerated by only the exact percentage necessary to fully replenish the supply of softened water to 100%.
Note: With intelligent regeneration, the remaining supply of softened water is not wasted.
This intelligent regeneration method is possible because of the precision flowmeter, which is able to adjust the amount of brine required for partial regeneration. The consumption of regenerative and water is reduced to the required minimum.
In the event of a power failure, the data and the time are retained (for approx 72 hours).
The unit is optionally equipped with a device that disinfects the ion exchange resin during the regeneration. A spring-loaded non-return valve (18) is optionally available (see page 5).
Automatic regeneration triggering:
This is an optional setting - not as standard on all softeners.
4.2 Operation
Setting the Type of Salt used
To operate effectively, your water softener must be set to the type of salt you intend to use in the system.
The Care cubes are suitable.
Pressing the [SET] button will return the display to the Normal Operation mode. Programming is now complete and no further adjustment of the water softener is required.
Remember to check the salt and water level in the brine cabinet weekly.
14
Charge Bar
Having set the display on the control facia, you will notice that during normal operation there is a charge bar running along the bottom of the display. This charge bar shows the percentage of water softener capacity remaining since the last regeneration. Immediately following a regeneration, the charge bar returns to 100%.
Resetting the display during operation.
If the time is to be adjusted during normal operation, press any key to illuminate the display, press the
[SET] key once. The display will flash and indicate present time. Using the keys will alter the time as described on page 7.
Power loss
The AMECS system will maintain the individual programming parameters of the water softener for up to 72 hours.
If the power cut lasts longer than 72 hrs, the control will flash “00:00“ when power is returned to the control. The unit will continue to keep time from the moment power is restored. In this situation the time of day will need to be reset.
Flow indicator
During normal operation, a flow indicator will flash on the display at a rate of one litre per pulse when water is passing through the softener.
Cleaning
Your water softener may be cleaned using a damp cloth and a mild detergent. Do not use bleaches, solvents or spirits as they may damage the surfaces.
Manual regeneration [recharge] button
Under normal operating conditions your water softener will regenerate automatically and you should not normally have to regenerate the unit manually.
If however a manual regeneration is required then follow the procedure set out below.
1. Press any key to illuminate the display.
2. Momentarily pressing the button (symbol underneath the display and furthest to the right) will illuminate Recharge Tonight on the display and perform a regeneration at 2.00 a.m. regar less of the remaining water softener capacity.
3. If the button is subsequently pressed, this will clear the Recharge Tonight indicator from the display and cancel the Recharge Tonight feature.
4. If the [recharge] button is pressed down for six seconds, the controller will flash the Recharge display and immediately commence the regeneration cycle which cannot be cancelled.
Adding regenerative
Refill the salt no later than when SALt is indicated on the display or 150mm above the base of the softener.
Acknowledge - low SALt alarm:
NOTE: This function is optional - not standard on all models.
Open the cover (4). Pour regenerative into the storage area (5).
Press [SET] and hold until the SALt display goes out.
Refill the unit in such a way that no dirt can get into the storage area (5) (if necessary, clean the packages containing the regenerative before use).
Clean the storage area or brine cavity (6) with clean water if it gets dirty.
Salt usage
Your water softener is controlled by a microprocessor which constantly monitors water usage.
The system will build up a history of your water requirements and calculate the most economical regeneration pattern. This will ensure a constant supply of softened water whilst maintaining high levels of water and salt efficiency. As your water softener uses a proportional brining system, more frequent regenerations do not necessarily mean high water
/ salt usage.
Increase in number or residents
Sudden changes in your water usage should not affect your water softeners performance. If however, the number of guests staying with you increases, you will notice that the water usage patterns will alter.
This may cause your water softener to regenerate more often than normal. As the water usage returns to its normal level, the number of regenerations will also return to normal.
Cabinet Water Level
During normal operation the water level inside the water softener cabinet will rise and fall as required by the regeneration process. If the water softener is used within the specified operational parameters the water level should not reach the overflow connection. If however an overflow situation occurs please refer to the troubleshooting section on page 17 to diagnose the problem.
15
EN
EN
Following any overflow situation reduce the water level by half and initiate a manual regeneration as described above.
NB: Check the water level weekly and following any unplanned event, e.g. powerfailure.
4.3 Setting the hardness of blended water
The unit is preset to 300 ppm.
To test the water hardness, allow the nearest cold water tap to run for a while and check the hardness of the blended water using the AQUATEST hardness tester.
Adjust with the blending valve V until the desired value is reached.
150
200
250
300
350
400
Hardness in ppm
No. of people
02
8
7
6
6
5
03
7
04
6
5
4
5
4
4
3
3
2
3 2 1
= Days between regeneration
2
1
1
4
3
05
5
5. Maintenance
5.1 Maintenance work
The operator must regularly perform the following checks to guarantee that the unit functions properly.
Check the regenerative and refill after use.
Check the water hardness: The hardness of drinking water and the set blended water hardness must be checked 2x annually and the hardness of the blended water must be corrected when required (see
Start-up).
Check for leaks, visual inspection: Check connection lines and connections for leaks. Check for dirt in the regenerative storage area and brine cavity every two months and clean and flush with clear water if necessary.
The intervals between checks are recommended minimums and must be adjusted according to site conditions.
1
1
1
3
2
06
4
5.2 Operator responsibilities
All technical equipment requires regular servicing in order to guarantee optimal functionality.
Keep yourself up to date with regard to the quality and pressure ratio of the water which is to be treated. If the water quality changes, the settings may need to be changed. Consult a specialist if this is the case.
Regular checks by the operator are required for the warranty and proper functioning of the unit. The water softener must be inspected regularly in accordance with the conditions of operation and use.
Operator checks intervalls:
After use:
2x Annually:
2x Annually:
1x Annually:
Refill regeneration salt
Check pressure
Check water quality
Clean brine container
5.3 Maintenance & wearing parts
Wearing parts must also be replaced within the prescribed maintenance intervals in order to guarantee functionality and fulfil the warranty conditions.
The water softener should be serviced once a year.
Wearing parts may only be replaced by qualified personnel (fitters or after-sales service team).
We recommend that you enter into a maintenance agreement with your fitter or the aftersales service team.
Cleaning information: Do not use alcohol or alcohol based cleaning agents, otherwise the plastic surfaces of the device will be damaged.
5.4 Disposal
At the end of product life please contact BWT Customer
Services to arrange a new replacement for your softener.
Disposal of your softener and any electrical parts should only be carried out at authorised WEEE recycling centres.
16
6. Fault finding
6.1 Trouble shooting Guide
Attention:
If your water softener is not performing as it should, please run through the check list below.
Checklist
Problem: Water still remains hard.
Is there a minimum of 150mm of salt in the brine cabinet?
Is the power on?
Is the softener online?
Solution
Fill the brine cabinet with salt.
Switch the power on and check connections.
Close the by-pass valve and open the inlet and outlet valves.
Reset the hardness if required.
Page
13
13
13
13, 16 Is the hardness setting correct?
Problem: Water level in brine cabinet reaches overflow.
Is the line pressure within the specification of the water softener?
Pressure falls outside of the water softener specification.
Is there flow through the drain line?
Has there been a power interruption?
Connect a pressure gauge to a water outlet and check the pressure is between: 1.7 - 5.0 bar for the UK / 1.0 - 8.0 bar for EU.
Fit a pressure reducing valve or booster pump as required. (see note below)
Check the drain line is not kinked, blockedor frozen.
Check that the power is on and the connections are secure.
8, 9, 10
8, 9, 10
11, 12
8, 14
Problem: No water.
Is the mains stop valve open?
Are the inlet and outlet valves of the water softener open?
Open the mains stop valve.
Open the inlet and outlet valves to the watersoftener.
13
13
EN
Note:
If any overflow situation occurs or if any of the above requires action reduce the water level by half and initiate a regeneration by pressing and holding the manual regeneration key [RECHARGE] for more than six seconds.
17
EN
Attention:
If your water softener is not performing as it should, please run through the check list below.
Checklist
Problem: Water runs from the drain constantly.
Is the unit in recharge mode?
Solution Page
Is the power on?
If yes, this is normal, wait until the recharge is complete.
7
There should be no flow to drain in the service position.
8
Problem: Excessive salt usage.
Check the hardness setting.
Problem: Electronic Display.
The display shows error code: “Err 1“, audible alarm sounds, (see note below).
OPTIONAL: The display shows error code:“SALt“, audible alarm sounds.
Is the digital display blank?
Reduce the hardness if incorrect.
7, 16
Check all the connections are secure. Turn the power off for 10 seconds then turn back on, allow the system to reset.
15
The low salt alarm is active. Fill the brine cabinet with salt. Pressing the [SET] key will reset the salt alarm to full capacity of salt.
15
Check the power is turned on and all theconnections are secure.
15
Problem: Unit regenerates at the wrong time.
Is the present time correct?
Reset the present time.
7
Note:
If the home position is not detected within 10 minutes , the main display will show an “Err 1“ message to indicate a controller error and an audible alarm will sound.
The error condition can only be cleared by removing and re-applying the power.
Attention:
If problem persists, please call your local dealer or after sales service team.
18
7. Technical data
7.1 BWT AQUADIAL softlife 10 / 10 Bio*
BWT AQUADIAL softlife
Nominal connection (outside thread)
Nominal flow rate in accordance with EN 14743
Nominal pressure (PN)
Operating pressure EU (min./max.)
Operating pressure UK (min./max.)
Pressure drop down at nominal flow in accordance with
EN 14743
Quantity of ion-exchange resin
Nominal capacity (EN 14743) / (CaCO3 mmol/l)
Capacity salt reservoir
Salt consumption per regeneration
Water consumption per regeneration
Protection class
Water temperature (min./max.)
Ambient temperature (min./max.)
Electrical connection
Dimension Width x Depth x Height (W x D2 x H)
Connection height (A) / Overflow height (S)
Operating weight, approx.
*Tested with HiFlow connection available in option
Type
BSP l/h bar bar bar bar l m³x°dH7mol/ppm kg kg l
IP
°C
°C
V / Hz mm mm kg
10 / 10 Bio
¾“ (DN 20)
1440
4
1.0 / 8.0
1.7 / 5.0
1.0
10
26 / 4.6 / 460
12
1.5
85
51
5 / 30
5 / 40
230 / 50
270 x 480 x 532
403 / 270
40
EN
D
1
D
2
W
19
EN
7.2 BWT AQUADIAL softlife 15 / 15 Bio*
BWT AQUADIAL softlife
Nominal connection (outside thread)
Nominal flow rate in accordance with EN 14743
Nominal pressure (PN)
Operating pressure EU (min./max.)
Operating pressure UK (min./max.)
Pressure drop down at nominal flow in accordance with
EN 14743
Quantity of ion-exchange resin
Nominal capacity (EN 14743) / (CaCO3 mmol/l)
Capacity salt reservoir
Salt consumption per regeneration
Water consumption per regeneration
Protection class
Water temperature (min./max.)
Ambient temperature (min./max.)
Electrical connection
Dimension Width x Depth x Height (W x D2 x H)
Connection height (A) / Overflow height (S)
Operating weight, approx.
*Tested with HiFlow connection available in option
Type
BSP l/h bar bar bar bar l m³x°dH7mol/ppm kg kg l
IP
°C
°C
V / Hz mm mm kg
15 / 15 Bio
¾“ (DN 20)
1560
4
1.0 / 8.0
1.7 / 5.0
1.0
15
43 / 7.7 / 770
16
2.0
105
51
5 / 30
5 / 40
230 / 50
270 x 480 x 602
473 / 350
50
20
D
1
D
2
W
7.3 BWT AQUADIAL softlife 20 / 20 Bio*
BWT AQUADIAL softlife
Nominal connection (outside thread)
Nominal flow rate in accordance with EN 14743
Nominal pressure (PN)
Operating pressure EU (min./max.)
Operating pressure UK (min./max.)
Pressure drop down at nominal flow in accordance with
EN 14743
Quantity of ion-exchange resin
Nominal capacity (EN 14743) / (CaCO3 mmol/l)
Capacity salt reservoir
Salt consumption per regeneration
Water consumption per regeneration
Protection class
Water temperature (min./max.)
Ambient temperature (min./max.)
Electrical connection
Dimension Width x Depth x Height (W x D2 x H)
Connection height (A) / Overflow height (S)
Operating weight, approx.
*Tested with HiFlow connection available in option
Type
BSP l/h bar bar bar bar l m³x°dH7mol/ppm kg kg l
IP
°C
°C
V / Hz mm mm kg
20 / 20 Bio
¾“ (DN 20)
1680
4
1.0 / 8.0
1.7 / 5.0
1.0
10
60 / 10.7 / 1070
24
2.5
125
51
5 / 30
5 / 40
230 / 50
270 x 480 x 532
675 / 540
65
EN
D
1
D
2
W
21
EN
7.4 BWT AQUADIAL softlife 25 / 25 Bio*
BWT AQUADIAL softlife
Nominal connection (outside thread)
Nominal flow rate in accordance with EN 14743
Nominal pressure (PN)
Operating pressure EU (min./max.)
Operating pressure UK (min./max.)
Pressure drop down at nominal flow in accordance with
EN 14743
Quantity of ion-exchange resin
Nominal capacity (EN 14743) / (CaCO3 mmol/l)
Capacity salt reservoir
Salt consumption per regeneration
Water consumption per regeneration
Protection class
Water temperature (min./max.)
Ambient temperature (min./max.)
Electrical connection
Dimension Width x Depth x Height (W x D2 x H)
Connection height (A) / Overflow height (S)
Operating weight, approx.
*Tested with HiFlow connection available in option
Type
BSP l/h bar bar bar bar l m³x°dH7mol/ppm kg kg l
IP
°C
°C
V / Hz mm mm kg
25 / 25 Bio
¾“ (DN 20)
1680
4
1.0 / 8.0
1.7 / 5.0
1.0
15
75 / 13.4 / 1340
24
3.0
145
51
5 / 30
5 / 40
230 / 50
270 x 480 x 602
675 / 540
70
22
D
1
D
2
W
EC declaration of incorporation *
)
BWT UK Ltd.
Coronation Road, BWT House
High Wycombe
Buckinghamshire, HP12, 3SUH
The company BWT UK Ltd.
declares that the product domestic water softener with the following specifications:
Trade name of product Type of product Model
• BWT AQUADIAL softlife 10 / 10 BIO 10 litres
• BWT AQUADIAL softlife
• BWT AQUADIAL softlife
• BWT AQUADIAL softlife
15 / 15 BIO
20 / 20 BIO
25 / 25 BIO
15 litres
20 litres
25 litres with a serial number higher than: 1105 000101 and with a production- and reference no.: see rating plate & technical specifications have been designed, manufactured and assembled according to the following
EC Directives (guidelines):
2006/95/EC Guideline for low voltage (LVD)
2004/108/EC Guideline for electromagnetic compatibility (EMC)
Note: Do not perform any changes, extension and reconstruction work on the device which might impair safety without the approval of BWT UK Ltd., otherwise this declaration loses its validity.
Note: Please ensure that all conditions of the installation preconditions are met!
Buckinghamshire, 30 th May 2011
Ian Threadgill
General Manager (Supply Chain)
Manufacturer: BWT UK Ltd. – Coronation Road – Buckinghamshire, HP12, 3SUH
23
EN