Keysight M8195A Arbitrary Waveform Generator Quick Start Guide
Advertisement
Advertisement
Keysight M8195A
Arbitrary Waveform
Generator Revision 1
Getting Started Guide
Notices
Copyright Notice
© Keysight Technologies 2017
No part of this manual may be repro- duced in any form or by any means
(including electronic storage and retrieval or translation into a foreign language) without prior agreement and written con- sent from Keysight Technologies, Inc. as governed by United States and interna- tional copyright laws.
Manual Part Number
M8195-91010
Edition
Edition 3.0, October 2017
Printed in
Printed in Malaysia
Published by
Keysight Technologies
Deutschland GmbH,
Herrenberger Str. 130,
71034 Böblingen, Germany
Technology Licenses
The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
ESD Sensitive Device
All front-panel connectors of the
M8195A are sensitive to Electrostatic discharge (ESD). We recommend to operate the instrument in an electrostatic safe environment.
There is a risk of instrument malfunction when touching a connector.
Please follow this instruction:
Before touching the front-panel connectors, discharge yourself by touching the properly grounded mainframe.
U.S. Government
Rights
The Software is “commercial computer software,” as defined by Federal Acquisi- tion Regulation (“FAR”) 2.101. Pursuant to FAR 12.212 and 27.405-3 and Depart- ment of Defense FAR Supplement
(“DFARS”) 227.7202, the U.S. govern- ment acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight pro- vides the Software to U.S. government customers under its standard commercial license, which is embodied in its End
User License Agreement (EULA), a copy of which can be found at http:// www.keysight.com/find/sweula . The li- cense set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical infor- mation related to commercial computer software or commercial computer soft- ware documentation that is not custom- arily provided to the public; or (2) Relin- quish to, or otherwise provide, the gov- ernment rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, dis- play, or disclose commercial computer software or commercial computer soft- ware documentation. No additional gov- ernment requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer soft- ware pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the
U.S. government acquires no greater than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as appli- cable in any technical data.
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,”
AND IS SUBJECT TO BEING
CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO
THE MAXIMUM EXTENT PERMITTED
BY APPLICABLE LAW, KEYSIGHT
DISCLAIMS ALL WARRANTIES, EI-
THER EXPRESS OR IMPLIED, WITH
REGARD TO THIS MANUAL AND
ANY INFORMATION CONTAINED
HEREIN, INCLUDING BUT NOT LIM-
ITED TO THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PUR-
POSE. KEYSIGHT SHALL NOT BE
LIABLE FOR ERRORS OR FOR INCI-
DENTAL OR CONSEQUENTIAL DAM-
AGES IN CONNECTION WITH THE
FURNISHING, USE, OR PERFOR-
MANCE OF THIS DOCUMENT OR OF
ANY INFORMATION CONTAINED
HEREIN. SHOULD KEYSIGHT AND
THE USER HAVE A SEPARATE
WRITTEN AGREEMENT WITH WAR-
RANTY TERMS COVERING THE MA-
TERIAL IN THIS DOCUMENT THAT
CONFLICT WITH THESE TERMS,
THE WARRANTY TERMS IN THE
SEPARATE AGREEMENT SHALL
CONTROL.
Safety Information
CAUTION
A CAUTION notice denotes a hazard.
It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met .
WARNING
A WARNING notice denotes a haz- ard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a
WARNING notice until the indicated conditions are fully understood and met.
Safety Summary
General Safety
Precautions
The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. For safe operation the general safety precautions for the M9502A and M9505A AXIe chassis, must be followed.
See: http://www.keysight.com/find/M9505A Keysight Technologies Inc. assumes no liability for the customer's failure to comply with these requirements. Before operation, review the instrument and manual for safety markings and instructions.
You must follow these to ensure safe operation and to maintain the instrument in safe condition.
Initial Inspection
Inspect the shipping container for damage. If there is damage to the container or cushioning, keep them until you have checked the contents of the shipment for completeness and verified the instrument both mechanically and electrically. The
Performance Tests give procedures for checking the operation of the instrument. If the contents are incomplete, mechanical damage or defect is apparent, or if an instrument does not pass the operator’s checks, notify the nearest Keysight
Technologies Sales/Service Office.
WARNING To avoid hazardous electrical shock, do not perform electrical tests when there are signs of shipping damage to any portion of the outer enclosure
(covers, panels, etc.).
General
This product is a Safety Class 3 instrument. The protective features of this product may be impaired if it is used in a manner not specified in the operation instructions.
Environment
Conditions
This instrument is intended for indoor use in an installation category II, pollution degree 2 environment. It is designed to operate within a temperature range of 0
°C – 40 °C (32 °F – 105 °F) at a maximum relative humidity of 80% and at altitudes of up to 2000 meters.
This module can be stored or shipped at temperatures between -40 °C and +70 °C.
Protect the module from temperature extremes that may cause condensation within it.
Before Applying Power
Verify that all safety precautions are taken including those defined for the mainframe.
Line Power
Requirements
The Keysight M8190A operates when installed in an Keysight AXIe mainframe.
Do Not Operate in an
Explosive Atmosphere
Do not operate the instrument in the presence of flammable gases or fumes.
Do Not Remove the
Instrument Cover
Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made only by qualified personnel. Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel.
Safety Symbols
Table 1 Safety Symbol
Symbol Description
Indicates warning or caution. If you see this symbol on a product, you must refer to the manuals for specific Warning or Caution information to avoid personal injury or damage to the product.
C-Tick Conformity Mark of the Australian ACA for EMC compliance.
CE Marking to state compliance within the European Community: This product is in conformity with the relevant European Directives.
General Recycling Mark
Table 2 Compliance and Environmental Information
Symbol Description
This product complies with the WEEE Directive (2002/96/EC) marketing requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste.
Product category: With reference to the equipment types in the WEEE Directive Annexure I, this product is classed as a “Monitoring and Control instrumentation” product.
Do not dispose in domestic household waste.
To return unwanted products, contact your local Keysight office, or see http://about.keysight.com/en/companyinfo/environment/takeback.shtml
for more information.
1
Contents
Introduction
Power and Ventilation Requirements 29
Contents
M8195A Getting Started Guide 7
Introduction
Keysight M8195A – Arbitrary Waveform Generator
Getting Started Guide
1 Introduction
The Keysight M8195A is a 65 GSa/s Arbitrary Waveform Generator with highest bandwidth and channel density. It offers up to 16 GSa waveform memory. The
M8195A is ideally suited to address following key applications:
• Coherent optical – a single M8195A module can generate 2 independent
I/Q baseband signals (dual polarization = 4 channels) at up to 32 Gbaud and beyond.
• Multi-level / Multi-channel digital signals – generate NRZ, PAM4, PAM8,
DMT, etc. signals at up to 32 Gbaud. Embed/De-embed channels, add
Jitter, ISI, noise and other distortions.
• Physics, chemistry, and electronics research – generate any mathematically defined arbitrary waveforms, ultra-short yet precise pulses and extremely wideband chirps.
• Wideband RF/µW – generate extremely wideband RF signals with an instantaneous bandwidth of DC to 20 GHz for aerospace/defense/communication applications.
Introduction
Features and
Benefits
The M8195A is an arbitrary waveform generator with highest sample rate, bandwidth, and channel density:
• Sample rate up to 65 GSa/s (on each channel)
• Analog bandwidth: 20 GHz
• Vertical resolution: 8 bits
• 1, 2, or 4 differential channels per 1-slot high AXIe module (number of channels is software upgradable)
• Built-in frequency and phase response calibration
• Amplitude up to 1 Vpp (single ended) (2 Vpp (differential))
• VT
Rise,20%...80%
T
Fall,20%...80%
:18 ps (typ.)
• Ultra low intrinsic Random Jitter RJ rms
< 200 fs
• Form factor: 1-slot AXIe module controlled via external PC or embedded
AXIe system controller M9536A
10 M8195A Getting Started Guide
Introduction
Getting Started with
M8195A
The M8195A is a modular instrument packaged in the AXIe form factor. AXIe is an open standard for high-performance modular instrumentation. Different form factors of AXIe chassis are available: 13-slot, 5-slot and 2-slot AXIe chassis.
An M9536A AXIe embedded controller can control one or multiple M8195A AWG.
This embedded controller consumes one module slot of the AXIe chassis. Besides using an embedded controller, the M8195A AWG can be controlled by an external desktop PC or an external laptop as well through PCIe or USB port. In case of PCIe, a
PCIe adapter card and PCIe cable are needed whereas USB connection simply requires a USB cable.
There are two different ordering possibilities:
• M8195A AWG, AXIe chassis, PCIe cable, PCIe adapter card and PC are ordered separately. The different components come in different packages and need to be installed. Please follow the instructions given in chapter 3 of
M8195A user’s guide or the instructions given in the user’s guide of the
AXIe chassis.
• M8195S system configuration
System that is dynamically configured depending on the required number of M8195A AWG modules and AXIe chassis type. An embedded controller or PC connectivity will automatically be added and the system ships preconfigured.
• In case an M9536A embedded controller has been ordered as part of the
M8195S system configuration, the M8195A firmware is already installed and configured on the embedded controller.
User set up:
Username: M8195a_admin
Password: admin!123
Directory of the software:
Firmware:
C:\Program Files (x86)\Keysight\M8195\bin
M8195A Getting Started Guide 11
Introduction
Additional
Documents
Additional documentation can be found at:
• http://www.keysight.com/find/M9514A for 13-slot chassis related documentation.
• http://www.keysight.com/find/M9505A for 5-slot chassis related documentation.
• http://www.keysight.com/find/M9502A for 2-slot chassis related documentation.
• http://www.keysight.com/find/M9045A for PCIe laptop adapter card related documentation.
• http://www.keysight.com/find/M9047A for PCIe desktop adapter card related documentation.
• http://www.keysight.com/find/M9536A for embedded AXIe controller related documentation.
• http://www.keysight.com/find/M8195A for AXIe based AWG module related documentation.
12 M8195A Getting Started Guide
Keysight M8195A – Arbitrary Waveform Generator
Getting Started Guide
2 M8195A Software
Installation
2.1
Pre-Requisites
2.1
2.2
2.3
2.4
Pre-Requisites
/ 13
Installation Process
/ 14
Post Installation Steps
/ 22
How to use the Instrument
/ 23
This chapter explains the steps required to install M8195A software package.
The following are the pre-requisites for installing Keysight M8195A software:
• The supported operating systems are:
− Windows 8.1 (32 bit or 64 bit)
− Windows 8 (32 bit or 64 bit)
− Windows 7 (32 bit or 64 bit)
• Ensure that you have Keysight IO Libraries Suite Version 16.3 or higher installed on your system. The Keysight IO Libraries Suite can be found on the CD that is part of shipment content or at http://www.keysight.com/find/iosuite
.
Even if a non-Keysight I/O library is already installed on your PC, it is still necessary to install the Keysight I/O library. The Keysight I/O library will install as “secondary”
I/O library in this case. This use case is fully supported. There only needs to be some additional considerations when doing SCPI remote programming. For more information on SCPI remote programming, refer to M8195A User's Guide.
M8195A Software Installation
2.2
Installation Process
Follow the given steps to install Keysight M8195A software on your system.
1.
Double-click the executable (M8195_Setup.exe). This executable file is available either on CD or Web.
The installer will first check and list some pre-requisites. Click Install to install them.
It is possible that your PC requests a reboot during this step. Reboot your PC, if requested.
14
2.
The Keysight M8195A Setup will prepare the InstallShield Wizard for the installation process. The following window will appear.
M8195A Getting Started Guide
M8195A Software Installation
3.
Follow the onscreen instructions to begin the installation process.
Click Next.
M8195A Getting Started Guide
4.
We recommend you to read the document to check if your hardware configuration is supported.
Click Next to proceed to the license agreements.
15
M8195A Software Installation
5.
Accept the terms of Keysight software end-user license agreement.
16
6.
Click Next.
M8195A Getting Started Guide
M8195A Software Installation
7.
Select Yes if you want to read the post-installation instructions when finished.
Click Next to select setup type.
M8195A Getting Started Guide
8.
Select a setup type either Complete or Custom.
Click Next.
17
M8195A Software Installation
If you select Custom and click Next, you can specify which optional features will be installed:
18 M8195A Getting Started Guide
M8195A Software Installation
9.
Click Next to begin installation.
10.
The Setup Wizard will now install M8195 beginning with USB driver installation
M8195A Getting Started Guide 19
M8195A Software Installation
11.
The Keysight M8195A will configure the new software installation.
20
12.
The following screen will appear once the Keysight M8195A software is successfully installed on your system.
Click Finish to restart your system. Do not connect the AXIe chassis to your system using the PCIe or USB cable during this reboot.
M8195A Getting Started Guide
M8195A Software Installation
This completes the Keysight M8195A software installation.
M8195A Getting Started Guide 21
M8195A Software Installation
2.3
Post Installation Steps
Follow the post installation steps as shown below:
If M8195A is already powered up and connected to PC using the PCIe, just reboot the
PC and start with step 5. No such reboot step is required in case of USB connection.
1.
Shut down PC and instrument.
2.
Connect the instrument to the PC using the PCIe or USB cable.
3.
Switch on the instrument. Wait until the ‘Access’ LED of the M8195A has switched from red to green.
4.
Switch on the PC.
5.
The PC should automatically recognize the instrument.
Check this in the device manager; e.g. via Start > Control Panel > Device Manager, or right-click Computer > Manage > Device Manager:
• In case of PCIe:
The instrument should be visible in the device tree as Agilent Technologies
Modular Devices > M8195A
• In case of USB:
The instrument should be visible in the device tree as Agilent Modular
Platform (AMP/AXIe) > Agilent Technologies USB AMP/AXIe Chassis.
In case of PCIe, post installation steps must be followed strictly in the same order as mentioned for successful connection of the PC with M8195A. However, in case of
USB no such restriction is applicable i.e. the PC can be powered before the M8195 is turned ON.
Your PC might request a reboot. Reboot your PC, if requested.
6.
Check if the M8195 is also visible in the Connection Expert. The connection expert can be opened by clicking its icon in the system tray.
If something went wrong and the instrument is not showing in the PXI section, it may be necessary to reboot the PC once more.
22 M8195A Getting Started Guide
M8195A Software Installation
2.4
How to use the Instrument
In order to use the instrument:
1.
If you use a PCIe link to control the M8195A, the AXIe chassis must be switched on before you start the PC. If you use an USB link to control the
M8195A, it’s not mandatory that the AXIe chassis is powered and has booted prior to turn-on the PC.
2.
Start the
M8195A Soft Front Panel
(Start > All Programs > Keysight
M8195 > Keysight M8195 Soft Front Panel). The user interface will display the VISA resource strings for different kinds of connection.
3.
Using the appropriate VISA resource string you can:
− Start the Soft Front Panel (Start > All Programs > Keysight M8195 >
Keysight M8195 Soft Front Panel).
− Control the instrument with your own application using the M8195 IVI
Drivers or add it as a LAN instrument in the Keysight Connection
Expert (TCPIP0::localhost::…) and control it using SCPI (with e.g. the
VISA Assistant or your own application).
You must start the M8195A Soft Front Panel in order to send SCPI commands to the instrument.
The M8195 IVI Drivers start the M8195A Soft Front Panel automatically.
M8195A Getting Started Guide 23
Keysight M8195A – Arbitrary Waveform Generator
Getting Started Guide
3 AXle Chassis
3.1
ESM Front Panel Connector
/ 25
Introduction This chapter describes the usage of the AXIe chassis in combination with the M8195A.
The detailed documentation for the AXIe chassis can be found at:
• http://www.keysight.com/find/M9514A for 13-slot chassis
• http://www.keysight.com/find/M9505A for 5-slot chassis
• http://www.keysight.com/find/M9502A for 2-slot chassis
3.1
ESM Front Panel Connector
The ESM Front Panel Connector is shown in the figure below:
AXle Chassis
5
6
3
4
1
2
PCle
USB
Multiframe Input
Multiframe Output
Trigger In
Trigger Out
7
8
9
Clock In
Clock Out
LAN
10 Status Light
Connects a host PC to the chassis via PCle.
Connects a host PC to the chassis via USB 2.0. The USB 2.0 port is only available for AXIe chassis with option -U20.
Synchronizes timing signals with multiple daisy-chained chassis.
External Trigger connections.
The Trigger In of the AXIe ESM cannot be used to trigger the M8195A.
The M8195A has its own Trigger In.
The Trigger Out of the AXIe ESM cannot be controlled by the M8195A.
External clock connections.
Connects the host PC to the chassis, via 10/100/1000 Ethernet.
In particular, the LAN connector is used for ESM configuration, but
NOT to communicate to the M8195A.
Indicates the chassis status.
26 M8195A Getting Started Guide
Keysight M8195A – Arbitrary Waveform Generator
Getting Started Guide
4 M8195A Maintenance
4.1
4.2
4.3
4.4
4.5
ESD Protection
/ 28
Power and Ventilation Requirements
/ 29
Thermal Protection
/ 29
Battery
/ 29
Cleaning Recommendation
/ 29
Introduction This chapter explains how to install and maintain the M8195A. It covers the following topics:
• ESD Protection
• Power & Ventilation Requirements
• Thermal Protection
• Battery
• Operating Environment
• Cleaning Recommendation
4.1
ESD Protection
Caution
All the connectors are very sensitive to electrostatic discharge (ESD). When you connect a device or cable that is not fully discharged to these connectors, you risk damage to the instrument and expensive instrument repairs.
Caution
Electrostatic discharge (ESD) can damage the circuits of the M8195A. Avoid applying static discharges to the front-panel connectors. Before connecting any coaxial cable to the connectors, momentarily short the center and outer conductors of the cable together. Avoid touching the front-panel connectors without first touching the frame of the instrument. Be sure the instrument and all connected devices (DUT, etc.) are properly earth-grounded (to a common ground) to prevent buildup of static charge and electrical over-stress.
M8195A Maintenance
4.2
Power and Ventilation Requirements
For power and ventilation requirements, refer to:
• http://www.keysight.com/find/M9514A for 13-slot chassis related documentation.
• http://www.keysight.com/find/M9505A for 5-slot chassis related documentation.
• http://www.keysight.com/find/M9502A for 2-slot chassis related documentation.
4.3
Thermal Protection
Overheating
Detection
The instrument monitors its internal temperature. If the temperature exceeds approximately 80°C the power supply is switched off. The instrument will not turn on automatically if the temperature is decreasing again.
Fan Failure If a fan is broken or prevented from operating by a blockage the temperature will increase. When the temperature exceeds approximately 80°C the overheating detection switches off the instrument for safety reasons. For reliability it is recommended to send instruments with broken or defective fans immediately to
Keysight Service for repair.
4.4
Battery
The M8195A does not have a battery.
4.5
Cleaning Recommendation
WARNING
To prevent electrical shock, disconnect the instrument from mains before cleaning.
Use a dry cloth or one slightly dampened with water to clean external case parts. Do not attempt to clean internally.
29 M8195A Getting Started Guide
Keysight M8195A – Arbitrary Waveform Generator
Getting Started Guide
5 Characteristics
5.1
5.2
5.3
Performance Specification
/ 31
Operating Environment
/ 31
General
/ 31
5.1
Performance Specification
The performance specification can be found in the Data Sheet of the M8195A at: http://www.keysight.com/find/M8195A
5.2
Operating Environment
Storage Temperature
Operating Temperature
Humidity
Altitude
Installation
Pollution
−40 °C to +70 °C
0 °C to 40 °C
95%R.H. (at 40 °C)
Up to 2000 m
Category II
Degree 2
5.3
General
Power consumption
Safety designed to
EMC tested to
Warm-up time
Calibration interval
Cooling
Requirements
60 W (nom), 65 GSa/s operation
IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1
IEC61326-1
30 min
2 years recommended
When operating the M8195A choose a location that provides at least 80 mm of clearance at rear, and at least 30 mm of clearance at each side for the
AXIe chassis.
Keysight M8195A – Arbitrary Waveform Generator
Getting Started Guide
This information is subject to change without notice.
© Keysight Technologies 2017
Edition 3.0, October 2017
Printed in Malaysia www.keysight.com

Public link updated
The public link to your chat has been updated.
Advertisement