Keysight ESA and EMC Analyzers option AYX, BAA, AYQ, A4H, 1AX, A4J and 106 Installation Guide
Advertisement
Advertisement
Installation Note
Agilent Technologies ESA Spectrum Analyzers and EMC Analyzers Kits
Fast Time Domain Sweeps (Option AYX)
FM Demodulation (Option BAA)
Quasi Peak Detector (Option AYQ)
GPIB/Parallel (Option A4H)
RS-232/Parallel (Option 1AX)
IF, Sweep, and Video Output (Option A4J)
Bluetooth FM Demodulator (Option 106)
Part Number E4401-90485 Supersedes: E4401-90452
Printed in USA May 2009
Notice.
The information contained in this document is subject to change without notice.
Agilent Technologies makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Microsoft
®
is a U.S. registered trademark of Microsoft Corp.
© Copyright 1999-2009 Agilent Technologies, Inc.
Introduction
This procedure can be used for all of the following assemblies:
• A7A1 IF Sweep, Video Output Assembly (Option A4J)
• A7A2 GPIB/Parallel Assembly (Option A4H)
• A7A3 RS-232/Parallel Assembly (Option 1AX)
• A7A5 Fast ADC Assembly (Option AYX)
• A7A6 FM Demod Assembly (Option BAA)
• A7A10 Bluetooth FM Demod Assembly (Option 106)
• A7A11 Quasi Peak Detector and FM Demod Assembly (Option AYQ)
Products Affected: . . . . . . . . . . . . . . . . . . . . . . . . . E4401B
E4402B
E4403B
E4404B
E4405B
E4407B
E4408B
E4411B
E7401A
E7402A
E7403A
E7404A
E7405A
Serial Numbers: . . . . . . . . . . . . . . . . . . . . . . . . . . . US00000000/US99999999
MY00000000/MY99999999
SG00000000/SG99999999
Options: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4H, 1AX, A4J, AYX, BAA, 106, and AYQ
To Be Performed By: . . . . . . . . . . . . . . . . . . . . . . (X) Agilent Technologies Service Center
(X) Personnel Qualified by Agilent
(X) Customer
Estimated Installation Time: . . . . . . . . . . . . . . . . 0.5 Hours per option
Estimated Verification Time: . . . . . . . . . . . . . . . . .
0.5 Hours per option
Installation Note E4401-90485 3
Installation Kit Parts Lists
Option AYX, Fast Time Domain Sweeps Parts Kit
Quantity
1
1
1
Description
Board Assembly, Fast ADC
Screw M3 x 8-mm (crest washer - pan head - TORX)
Installation Note
Option BAA, FM Demodulation Parts Kit
Quantity
1
1
1
Description
Board Assembly, FM Demodulation
Screw M3 x 8-mm (crest washer - pan head - TORX)
Installation Note
Option A4H, GPIB/Parallel Port Parts Kit
Quantity
1
1
1
1
Description
Board Assembly, GPIB/Parallel
ESA CD ROM Doc Set / Intuilink Toolbar
Screw M3 x 8-mm (crest washer - pan head - TORX)
Installation Note
Option AYQ, Quasi Peak Detector Parts Kit
Quantity
1
1
1
Description
Board Assembly, Quasi Peak/FM Demod
Screw M3 x 8-mm (crest washer - pan head - TORX)
Installation Note
Part Number
E4401-60083
0515-0372 this note
Part Number
E4401-60408
0515-0372 this note
Part Number
E4401-60320
–––––––––
0515-0372 this note
Part Number
E7401-60003
0515-0372 this note
4 Installation Note E4401-90485
Option 1AX, RS-232/Parallel Port Parts Kit
Quantity
1
1
1
1
1
Description
Board Assembly, RS-232/Parallel
ESA CD ROM Doc Set / Intuilink Toolbar
Screw M3 x 8-mm (crest washer - pan head - TORX)
RS-232 Cable
Installation Note
Option A4J, IF, Sweep, and Video Output Parts Kit
Quantity
1
1
1
Description
Board Assembly, IF, Sweep and Video Output
Screw M3 x 8-mm (crest washer - pan head - TORX)
Installation Note
Option 106, Bluetooth FM Demod Kit
Quantity
1
1
1
Description
Board Assembly, Bluetooth FM Demod
Screw M3 x 8-mm (crest washer - pan head - TORX)
Installation Note
Part Number
E4401-60364
–––––––––
0515-0372
RS232-61601 this note
Part Number
E4401-60096
0515-0372 this note
Part Number
E4401-60223
0515-0372 this note
Installation Note E4401-90485 5
Tools Required
❏
T-10 TORX screwdriver
❏ T-15 TORX screwdriver
❏
Oscilloscope (Option A4J only)
❏ 50 Ω termination
Torque Settings
To avoid potential RFI leakage and prevent connector damage, tighten to the following torque limits:
Item
SMA Connectors
3-mm, T-10 TORX screws
4-mm, T-15 TORX screws
In-lb
8.5
9
21
Torque
N-cm
95
102
236
6 Installation Note E4401-90485
Procedure
WARNING Before you disassemble the instrument, turn the power switch OFF and unplug the instrument. Failure to unplug the instrument can result in personal injury.
CAUTION Electrostatic discharge (ESD) can damage or destroy electronic components. All work on electronic assemblies should be performed at a static-safe workstation.
Refer to the documentation that pertains to your instrument for information about static-safe workstations and ordering static-safe accessories.
Outer Cover Removal
1. Refer to
. Disconnect the spectrum analyzer from ac power (1) .
2. Remove any adapters or cables (2) connected to the front frame.
3. Carefully place the analyzer on the work surface with the front frame (3) facing down.
4. Position the handle (4) as shown.
5. Remove the four screws (5) that hold the rear frame and outer case in place.
6. Remove the rear frame (6) .
7. Pull the outer cover (7) off towards the rear of the instrument.
Installation Note E4401-90485 7
Figure 1 Outer Cover and Rear Frame Removal
8 Installation Note E4401-90485
Inner Shield Removal
1. Lay the instrument flat as shown in
.
2. Remove the 15 screws (2) and (3) attaching the inner shield to the chassis. Note that the number of screws attaching the inner shield may vary with option mixes.
3. Remove the inner shield (1) from the chassis.
Figure 2 Inner Shield Removal
Installation Note E4401-90485 9
Installing the Option
1. Refer to
. Loosen, but do not remove, all 9 of the screws (1) securing the boards and blank plates at the rear of the chassis.
2. Refer to
. Remove the vibration support bar (1) at the top rear of the instrument by pressing in the locking tabs (2) and rotating the bar upward. The bar can be removed by sliding it out of the holes in each assembly.
Figure 3 Instrument, Rear View
10 Installation Note E4401-90485
CAUTION The vibration support bar can easily be broken if it is forced.
Remove it with care.
Figure 4 Removing the Vibration Support
3. Refer to
and Table 1 to locate where the new assembly will be installed.
4. Remove the single screw (1) securing the assembly or blank panel to the chassis.
5. Carefully pull up on the blank panel or assembly, to remove it from the instrument.
6. Carefully plug the assembly into one of the slots according to Table 1 .
7. Replace the screw (1) that secures the assembly being installed, but do not tighten it yet.
Installation Note E4401-90485 11
Table 1 Option and Slot Compatibility
Description Option Slot
A7A2 GPIB/Parallel Assembly a
A7A3 RS-232/Parallel Assembly a
A7A5 Fast Time Domain Sweep Assembly
A4H
1AX
AYX
1
1
3 or 4
A7A6 FM Demod Assembly
A7A1 IF Sweep, Video Output Assembly
A7A10 Bluetooth FM Demod Assembly
BAA
A4J
106
3 or 4
5 or 6
3 or 4
A7A11 Quasi Peak/FM Demod Assembly AYQ 3 or 4 a. Only the A7A2 GPIB/Parallel assembly OR the A7A3
RS-232/Parallel assembly should be installed at any one time. If both assemblies are installed, only the assembly in the lowest-numbered slot will be functional.
8. Refer to
. Replace the vibration support bar (1) as follows: a. Position the vibration support bar (1) as shown and insert the hook (2) into the IF’s support arm.
b. Engage each hook (3) of the other assemblies or blanks in turn.
c. As you position each of the assemblies or blanks, rotate (4) the support bar to lock each one in place.
d. Refer to Figure 6 . Make sure that the tab
(1) is positioned in the slot of the power supply chassis and the vibration bar is fully seated and locked (2) into position.
12 Installation Note E4401-90485
CAUTION The vibration support bar can easily be broken if it is forced. Install it with care.
Figure 5 Installing the Vibration Support Bar
Installation Note E4401-90485 13
Figure 6 Seating the Vibration Support Bar
9. Tighten all the screws that were loosened in the removal procedure to 101 N-cm (9 in-lb).
10.Refer to Figure 2 . Carefully position the inner shield
(1) on the instrument.
11.Replace the screws (2) and (3) , and tighten them to 101 N-cm (9 in-lb).
12.Carefully place the spectrum analyzer on the work surface with the front frame facing down.
13.Replace the instrument outer cover aligning the grill on the side of the case to the fan on the A5 power supply assembly.
14.Fit the leading edge of the case completely into the slot on the back of the front frame assembly.
15.Refer to
Figure 1 . Replace the rear frame assembly
(6) using the four screws (5) to fasten the rear frame to the instrument. Tighten the screws to 236 N-cm (21 in-lb).
14 Installation Note E4401-90485
Important Information
If the upgrade being installed is Option A4H, GPIB/Parallel or Option 1AX, RS-232/Parallel, the instrument firmware may need to be upgraded.
Firmware Revision Verification for Upgrade Options A4H and 1AX
Instructions for all ESA Spectrum Analyzers (E4401B, E4402B, E4403B, E4404B, E4405B,
E4407B, E4408B, E4411B):
NOTE If you have upgraded an EMC analyzer with GPIB/Parallel or RS-232/Parallel (E7401A,
E7402A, E7403A, E7404A, or E7405A) go to the section “Instructions For All EMC
Analyzers (E7401A, E7402A, E7403A, E7404A, E7405A)”
below
1. Turn on the analyzer and wait for the power-on alignments to complete. Check that there are no error messages displayed.
2. Press System , More , Show System . Make a note of the firmware revision and see if Option B72,
Expansion Memory, is listed on the display.
3. If Option B72 is installed, the firmware revision MUST be A.12.00 or greater. If the firmware revision is A.12.00 or greater, you can proceed to the performance and functional testing for the upgrade being performed. If the firmware revision is less than A.12.00, the firmware MUST be upgraded to the latest version using one of the following methods:
• Download the instrument firmware via the world-wide web at http://www.agilent.com/find/esa_firmware. This entire process of upgrading firmware will take approximately 45 minutes.
• Receive the latest firmware upgrade disk set by ordering upgrade Option UE2.
4. If Option B72 is not installed, you should upgrade the instrument firmware to the latest version for instruments that do not have Option B72 installed using one of the following methods:
• Download the instrument firmware via the world-wide web at http://www.agilent.com/find/esa_firmware_std-mem. This entire process of upgrading firmware will take approximately 45 minutes. If the version of firmware in your instrument is the same as at this website, you can proceed to the performance and functional testing for the upgrade being performed.
• Order upgrade Option B72, which includes the expansion memory and the latest ESA firmware upgrade disk set.
Instructions For All EMC Analyzers (E7401A, E7402A, E7403A, E7404A, E7405A)
1. Press System , More , Show System . Make a note of the firmware revision.
2. If the firmware revision is A.12.00 or greater, you do not need to upgrade the instrument firmware and you can proceed to the performance and functional testing for the upgrade being performed. If the firmware revision is less than A.12.00, the firmware MUST be upgraded to the latest version using one of the following methods
• Download the instrument firmware via the world-wide web at http://www.agilent.com/find/emc_firmware. This entire process of upgrading firmware will take approximately 45 minutes.
• Receive the latest firmware upgrade disk set by ordering upgrade Option UE2.
Installation Note E4401-90485 15
Performance Testing
Refer to the calibration guide for the instrument being upgraded and perform the following performance verification tests:
• Displayed Average Noise Level
• Residual Responses
• Sweep Time Accuracy (Option AYX only)
Functional Testing
❏ Option A4H, GPIB/Parallel.
1. Connect to GPIB Controller.
2. Send and receive data.
3. Remove cable from the GPIB connector and install the protective caps on the GPIB and parallel connectors.
NOTE A CD-ROM containing IntuiLink Toolbar software is included with this Option
A4H installation kit. This program allows you to download spectrum analyzer display or data files to a personal computer using Microsoft
®
Word or Microsoft
®
Excel. The IntuiLink Toolbar program is not required for the installation, functional testing, or operation of Option A4H. IntuiLink Toolbar installation instructions are included with the CD-ROM should you wish to install this program.
❏ Option 1AX, RS-232/Parallel.
1. Connect to RS-232 Controller.
2. Send and receive data.
3. Remove cable from the RS-232 connector and install the protective caps on the RS-232 and parallel connectors.
NOTE A CD-ROM containing IntuiLink Toolbar software is included with this Option
1AX installation kit. This program allows you to download spectrum analyzer display or data files to a personal computer using Microsoft Word ® 1
or
Microsoft
®
Excel. The IntuiLink Toolbar program is not required for the installation, functional testing, or operation of Option 1AX. IntuiLink Toolbar installation instructions are included with the CD-ROM should you wish to install this program.
1. Microsoft
®
is a U.S. registered trademark of Microsoft Corp.
16 Installation Note E4401-90485
❏ Option A4J, IF, Sweep, and Video Output.
Use an oscilloscope on the following outputs and confirm the presence of a signal.
1. SWP OUT a. Analyzer settings
Preset
Frequency 50 MHz
Span 0 Hz b. Check for a sweep ramp of 0 to +10 volts.
2. HI SWP OUT a. Analyzer settings
Preset
Frequency 50 MHz
Span 0 Hz b. Check for a 0 to 5 volt signal, TTL signal.
3. AUX VIDEO OUT a. Connect a BNC cable and type-N to BNC adapter between the AMPTD REF OUT and INPUT 50
Ω
. (E4402B, E4403B, E4404B, E4405B, E4407B, E4408B, E7402A,
E7403A, E7404A, and E7405A only) b. Analyzer settings
Preset
Input/Output , Amptd Ref (On) (E4401B, E4411B, and E7401A only)
Input/Output , Amptd Ref Out (On) (E4402B, E4403B, E4404B, E4405B, E4407B,
E4408B, E7402A, E7403A, E7404A, and E7405A only)
Frequency 50 MHz
Span 5 MHz , Bw/Avg 1 MHz
Amplitude , More , Amptd Units , dBm
Amplitude − 20 dBm
Scale Type (Lin) c. Press Amplitude and adjust the reference level to place the signal peak at the reference level. d. Trigger oscilloscope from HI SWP OUT (positive edge). Check for a 0 to 1 volt signal similar to that displayed on the analyzer’s display during the time when
HI SWP OUT is high.
4. AUX IF OUT a. Connect a BNC cable and type-N to BNC adapter between the AMPTD REF OUT and INPUT 50 Ω . (E4402B, E4403B, E4404B, E4405B, E4407B, E4408B, E7402A,
E7403A, E7404A, and E7405A only)
Installation Note E4401-90485 17
b. Analyzer settings
Preset
Input/Output , Amptd Ref (On) (E4401B, E4411B, and E7401A only)
Input/Output , Amptd Ref Out (On) (E4402B, E4403B, E4404B, E4405B, E4407B,
E4408B, E7402A, E7403A, E7404A, and E7405A only)
Frequency 50 MHz
Span 0 Hz
Amplitude , More , Amptd Units , dBm
Amplitude − 20 dBm
Scale Type (Lin) c. Press Amplitude and adjust the reference level to place the signal—the flat line—at the reference level. d. Check for a 21.4 MHz signal, approximately 200 mV p-p, with the oscilloscope input terminated in 50 Ω .
5. HI SWP IN a. Analyzer settings
Preset b. Connect a 50 Ω termination or short from the center lead of the HI SWP IN to ground.
Check to see that the analyzer stops sweeping.
❏
Option BAA, FM Demodulation and Option AYQ, Quasi Peak Detector/FM
Demodulation
1. Connect a BNC cable and type-N to BNC adapter between the AMPTD REF OUT and
INPUT 50 Ω . (E4402B, E4404B, E4405B, and E4407B only)
2. Analyzer settings
Preset
Input/Output , Amptd Ref (On) (E4401B only)
Input/Output , Amptd Ref Out (On) (E4402B, E4404B, E4405B, and E4407B only)
Frequency 50 MHz
Span , Zero Span
Bw/Avg , 3 MHz
Det/Demod , Demod , FM
Demod View (On)
1
Amplitude , Scale/Div , 20 kHz
2
Frequency 49.95
MHz
Marker , Delta
Frequency 50.05
MHz
3. The Marker Delta reading should be 100 kHz ± 5 kHz.
1.
2.
( firmware version A.03.03 or later only )
( firmware version earlier than A.03.03, use FM Deviation
,
100 kHz
)
18 Installation Note E4401-90485
❏ Option AYX, Fast Time Domain Sweeps
No functional testing is necessary; the Sweep Time Accuracy test is sufficient to verify performance.
❏
Option 106, Bluetooth FM Demodulation
1. Connect a BNC cable and type-N to BNC adapter between the AMPTD REF OUT and
INPUT 50
Ω
. (E4402B, E4404B, E4405B, and E4407B only)
2. Analyzer settings
Preset
Input/Output , Amptd Ref Out (On)
Frequency 50 MHz
Span , Zero Span
Bw/Avg , 3 MHz
Det/Demod , Demod , FM
BW/Avg , Average (On), 25 , ENTER
Frequency 49.85
MHz
Marker , Delta
Frequency 50.15
MHz
3. The Marker Delta reading should be 300 kHz
±
6 kHz.
Installation Note E4401-90485 19

Download