Keysight M9260A PXIe Audio Analyzer is a high-performance audio analyzer designed for a wide range of audio test applications. With its wide frequency range, high dynamic range, and low distortion, the M9260A is ideal for testing audio devices such as amplifiers, speakers, and microphones. The M9260A also includes a variety of built-in test functions, such as frequency response analysis, distortion analysis, and noise analysis. These functions make the M9260A a versatile tool for both design and manufacturing applications.
Here are some of the key features of the Keysight M9260A PXIe Audio Analyzer:
Advertisement
Advertisement
Keysight M9260A PXIe Audio
Analyzer
Startup Guide
2
Notices
Copyright Notice
© Keysight Technologies 2017 - 2018
No part of this manual may be reproduced in any form or by any means
(including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies as governed by United States and international copyright laws.
Manual Part Number
M9260-90000
Edition
Edition 3, May 2018
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies
Bayan Lepas Free Industrial Zone,
11900 Penang, Malaysia
Technology Licenses
The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this product and for other Keysight products may be downloaded from the
Web. Go to http://www.keysight.com/ go/conformity . You can then search by product number to find the latest Declaration of Conformity.
U.S. Government Rights
The Software is “commercial computer software,” as defined by Federal Acquisition Regulation (“FAR”) 2.101. Pursuant to FAR 12.212 and 27.405-3 and
Department of Defense FAR Supplement (“DFARS”) 227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly,
Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License
Agreement (EULA), a copy of which can be found at http://www.keysight.com/ find/sweula . The license set forth in the
EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight:
(1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, display, or disclose commercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS
227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR 27.401 or DFAR
227.7103-5 (c), as applicable in any technical data.
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,”
AND IS SUBJECT TO BEING
CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO THE
MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, KEYSIGHT DIS-
CLAIMS ALL WARRANTIES, EITHER
EXPRESS OR IMPLIED, WITH REGARD
TO THIS MANUAL AND ANY INFORMA-
TION CONTAINED HEREIN, INCLUD-
ING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. KEYSIGHT
SHALL NOT BE LIABLE FOR ERRORS
OR FOR INCIDENTAL OR CONSE-
QUENTIAL DAMAGES IN CONNECTION
WITH THE FURNISHING, USE, OR
PERFORMANCE OF THIS DOCUMENT
OR OF ANY INFORMATION CON-
TAINED HEREIN. SHOULD KEYSIGHT
AND THE USER HAVE A SEPARATE
WRITTEN AGREEMENT WITH WAR-
RANTY TERMS COVERING THE MATE-
RIAL IN THIS DOCUMENT THAT
CONFLICT WITH THESE TERMS, THE
WARRANTY TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.
Safety Information
CAUTION
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
WARNING
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death.
Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
Keysight M9260A Startup Guide
Safety Symbols
The following symbol on the instrument and in the documentation indicate precautions which must be taken to maintain safe operation of the instrument.
Caution, risk of danger (refer to this manual for specific Warning or Caution information)
Safety Considerations
Read the information below before using this instrument.
The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards for design, manufacture, and intended use of the instrument. Keysight
Technologies assumes no liability for the customer’s failure to comply with these requirements.
WARNING
– If this product is not used as specified, the protection provided by the equipment could be impaired. This product must be used in a normal condition (in which all means for protection are intact) only.
– No operator serviceable inside. Refer servicing to qualified personnel. To prevent electrical shock do not remove covers.
– To prevent electrical shock, disconnect the Keysight Technologies instrument from mains before cleaning. Use a dry cloth or one slightly dampened with water to clean the external case parts. Do not attempt to clean internally. To clean the connectors, use alcohol in a well ventilated area. Allow all residual alcohol moisture to evaporate, and the fumes to dissipate prior to energizing the instrument.
Keysight M9260A Startup Guide 3
CAUTION
– To maintain protection from electric shock and fire, replacement components in mains circuits - including the power transformer, test leads, and input jacks - must be purchased from Keysight. Standard fuses with applicable national safety approvals may be used if the rating and type are the same. Other components that are not safety-related may be purchased from other suppliers as long as they are equivalent to the original component (note that selected parts should be purchased only through Keysight to maintain accuracy and functionality of the product).
If you are unsure about the applicability of a replacement component, call a Keysight office for information.
– The maximum working voltage for the M9260A input port is ±46 Vp while the output port can only source up to ±10 Vp. Do not exceed the maximum M9260A input voltage to prevent damage to the module.
4 Keysight M9260A Startup Guide
Environmental Conditions
The M9260A is designed for indoor use and in an area with low condensation. The table below shows the general environmental requirements for this instrument.
Environmental condition
Temperature
Humidity
Altitude
Pollution degree
Requirement
Operating condition
– 0 °C to 55 °C
Storage condition
– –40 °C to 71 °C
Operating condition
– Up to 95% RH at 40 °C (non-condensing)
Storage condition
– Up to 90% RH at 65 °C (non-condensing)
Up to 3000 m
2
Keysight M9260A Startup Guide 5
6
Regulatory Information
The M9260A complies with the following safety and Electromagnetic
Compatibility (EMC) compliances:
Safety compliance
IEC 61010-1/EN 61010-1
EMC compliance
– IEC 61326-1/EN 61326-1 (Immunity for industrial electromagnetic environment)
– Canada: ICES/NMB-001: Issue 4, June 2006
– Australia/New Zealand: AS/NZS CISPR 11
Supplementary information:
– The product was tested in a typical configuration with Keysight Technologies test systems.
– This is a sensitive measurement apparatus by design and may have some performance loss when exposed to ambient continuous electromagnetic phenomenon.
Keysight M9260A Startup Guide
South Korean Class A EMC declaration:
Information to the user:
This equipment has been conformity assessed for use in business environments. In a residential environment this equipment may cause radio interference.
– This EMC statement applies to the equipment only for use in business environment.
사 용 자 안 내 문
이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서 가
정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다 .
– 사용자 안내문은 “ 업무용 방송통신기자재 ” 에만 적용한다 .
For Class B equipment there is no current statement required.
Keysight M9260A Startup Guide 7
8
Regulatory Markings
The CE mark is a registered trademark of the European Community. This CE mark shows that the product complies with all the relevant European Legal
Directives.
ICES/NMB-001 indicates that this ISM device complies with the
Canadian ICES-001.
Cet appareil ISM est conforme a la norme NMB-001 du Canada.
ISM GRP.1 Class A indicates that this is an Industrial Scientific and Medical
Group 1 Class A product.
This symbol is a South Korean Class A
EMC Declaration. This is a Class A instrument suitable for professional use and in electromagnetic environment outside of the home.
This symbol indicates the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use.
Forty years is the expected useful life of the product.
The RCM mark is a registered trademark of the Australian
Communications and Media Authority.
This instrument complies with the
WEEE Directive (2002/96/EC) marking requirement. This affixed product label indicates that you must not discard this electrical or electronic product in domestic household waste.
Keysight M9260A Startup Guide
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/
96/EC
This instrument complies with the WEEE Directive (2002/96/EC) marking requirement. This affixed product label indicates that you must not discard this electrical or electronic product in domestic household waste.
Product category
With reference to the equipment types in the WEEE directive Annex 1, this instrument is classified as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://about.keysight.com/en/companyinfo/environment/takeback.shtml
for more information.
Sales and Technical Support
To contact Keysight for sales and technical support, refer to the support links on the following Keysight websites:
– www.keysight.com/find/M9260A
(product-specific information and support, software and documentation updates)
– www.keysight.com/find/assist
(worldwide contact information for repair and service)
Keysight M9260A Startup Guide 9
10
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
Keysight M9260A Startup Guide
Table of Contents
Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Safety compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
EMC compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
South Korean Class A EMC declaration: . . . . . . . . . . . . . . . . . . . . . . .7
Waste Electrical and Electronic Equipment (WEEE) Directive
Product category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Sales and Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
1 Inspection, Installation, and Verification
Related documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Step 1: Unpack and Inspect the Module . . . . . . . . . . . . . . . . . . . . . . . .19
ESD precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Inspect the module for damage . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Return the module for service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Step 2: Verify the Shipment Contents . . . . . . . . . . . . . . . . . . . . . . . . . .23
Step 3: Install the Controller and Software . . . . . . . . . . . . . . . . . . . . . .24
System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Set up the controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Install the software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Step 4: Install the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
M9260A front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
M9260A audio analyzer functional block diagram . . . . . . . . . . . . . .33
Step 5: Verify the Operation of the M9260A Module . . . . . . . . . . . . . . .34
Conduct operational verification (optional) . . . . . . . . . . . . . . . . . . . .35
2 Characteristics and Specifications
Keysight M9260A Startup Guide 11
12
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
Keysight M9260A Startup Guide
List of Figures
Example of a static-safe work station . . . . . . . . . . . . .20
InstallShield Wizard for Keysight M9260A . . . . . . . . .27
Installing the module to the chassis . . . . . . . . . . . . . .29
Module installation procedures . . . . . . . . . . . . . . . . . .31
M9260A PXIe Audio Analyzer front panel . . . . . . . . . .32
M9260A functional block diagram . . . . . . . . . . . . . . . .33
M9260A SFP interface . . . . . . . . . . . . . . . . . . . . . . . . .34
Configuring the Analog Generator . . . . . . . . . . . . . . . .38
Configuring the Analog Analyzer . . . . . . . . . . . . . . . . .38
Configuring the Measurement . . . . . . . . . . . . . . . . . . .39
Initiating M9260A audio analyzer data acquisition . . .39
Keysight M9260A Startup Guide 13
14
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
Keysight M9260A Startup Guide
List of Tables
System requirements . . . . . . . . . . . . . . . . . . . . . . . . . .24
Configuration for M9260A audio analyzer . . . . . . . . . .37
Operational verification table . . . . . . . . . . . . . . . . . . . .40
Keysight M9260A Startup Guide 15
16
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
Keysight M9260A Startup Guide
Keysight M9260A PXIe Audio Analyzer
Startup Guide
1 Inspection, Installation, and Verification
Step 1: Unpack and Inspect the Module 19
Step 2: Verify the Shipment Contents 23
Step 3: Install the Controller and Software 24
Step 5: Verify the Operation of the M9260A Module 34
This chapter describes the inspection, installation, and verification of the M9260A
PXIe Audio Analyzer.
17
1 Inspection, Installation, and Verification
Introduction
The purpose of this Startup Guide is to describe the processes of inspecting and setting up the Keysight M9260A PXIe Audio Analyzer, installing the required software, and verifying the basic operation of the M9260A module.
If you have any questions after reviewing this information, please contact your local Keysight Technologies representative or contact us through our website at http://www.keysight.com/find/M9260A .
Related documentation
The Keysight M9260A PXIe Audio Analyzer documentation listed below can be downloaded for free through our website at http://www.keysight.com/find/
M9260A . You can check the manual revision on the second page of each manual.
– Keysight M9260A PXIe Audio Analyzer Startup Guide . This manual.
– Keysight M9260A PXIe Audio Analyzer Soft Front Panel Software and Help .
Embedded in the Soft Front Panel software.
– Keysight M9260A PXIe Audio Analyzer Programming Guide . For IVI-COM console applications.
– Keysight M9260A PXIe Audio Analyzer LabVIEW G Drivers Help .
– Keysight M9260A PXIe Audio Analyzer Data Sheet .
– Keysight M9260A PXIe Audio Analyzer Service Guide .
18 Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Step 1: Unpack and Inspect the Module
CAUTION
The M9260A PXIe Audio Analyzer is shipped in materials which prevent damage from static. The module should only be removed from the packaging in an anti-static area after ensuring that correct anti-static precautions are taken. Store all modules in anti-static envelopes when not in use.
ESD precaution
Electrostatic discharge (ESD) can damage or destroy electronic components. All work on electronic assemblies should be performed at a static-safe work station.
The following are the recommended ESD accessories and can be purchased from your local supplier.
– Conductive table mat with wrist-strap combination.
– Conductive floor mat with heel-strap combination.
Both types, when used together, provide a significant level of ESD protection. Of the two, only the table mat with wrist-strap combination provides adequate ESD protection when used alone. To ensure user safety, the static-safe accessories must provide at least 1 Ω of isolation from ground.
Figure 1-1 shows an example of a static-safe work station using both types of ESD
protection: conductive table mat with wrist-strap combination, and conductive floor mat with heel-strap combination.
Keysight M9260A Startup Guide 19
1 Inspection, Installation, and Verification
20
Figure 1-1 Example of a static-safe work station
WARNING
These techniques for a static-safe work station should not be used when working on circuitry with a voltage potential greater than 500 V.
Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Inspect the module for damage
Unpack the M9260A module from the shipping container. Keep the plastic port protectors and the shipping container for possible reuse.
After unpacking the M9260A module, carefully inspect the unit for any shipping damage. Report any damage to the shipping agent immediately, as such damage is not covered by the warranty.
The warranty also does not cover:
– Damage from contamination
– Normal wear and tear of mechanical components
– Manuals or fuses
CAUTION
To avoid damage when handling the M9260A module, do not touch the exposed connector pins.
NOTE
Information on preventing damage to your Keysight equipment can be found at www.keysight.com/find/tips .
Keysight M9260A Startup Guide 21
1 Inspection, Installation, and Verification
Return the module for service
Should it become necessary to return the M9260A for repair or service, follow the steps below:
1 Review the warranty information shipped with your product.
2 Contact Keysight to obtain a Return Material Authorization (RMA) and return address. If you need assistance finding Keysight’s contact information, go to www.keysight.com/find/assist (worldwide contact information for repair and service) or refer to the Support information on the product website at www.keysight.com/find/M9260A .
3 Write the following information on a tag and attach it to the defective M9260A.
– Name and address of owner. A P.O. box is not acceptable as a return address.
– Product model number (for example, M9260A).
– Product serial number (for example, MYXXXXXXXX). The serial number label is located on the side panel of the module. The serial number can also be read from the Soft Front Panel interface, but only after the software is installed.
– Description of failure or service required.
4 Carefully pack the module in its original ESD bag and packing carton. If the original carton is not available, use bubble wrap or packing peanuts and place the instrument in a sealed container and mark the container “FRAGILE” .
5 On the shipping label, write “ATTENTION REPAIR DEPARTMENT” and the RMA number.
NOTE
Refer to the product by its serial number and model number if any correspondence is required.
22 Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Step 2: Verify the Shipment Contents
The following items are included in the M9260A shipment:
– M9260A PXIe Audio Analyzer module
– Certificate of Calibration
NOTE
All software and product information files can be downloaded for free at www.keysight.com/find/M9260A.
Keysight M9260A Startup Guide 23
1 Inspection, Installation, and Verification
Step 3: Install the Controller and Software
System requirements
The following table lists the minimum system requirements for Keysight IO
Libraries Suite and controllers. In general, any x86 or x64 (except Itanium) architecture should work but there may be a significant decrease in performance if the processor speed is below the minimum requirements.
Table 1-1 System requirements
Operating system
Processor speed
Windows ® 7 SP1 (32 or 64-bit) or higher
– 1.5 GHz (x86 and x64) or higher
– Itanium 64 is not supported
2 GB minimum Available memory
Available hard-disk space [a]
Display Resolution
Input Device
Browser
Chassis
Embedded Controller
Remote Controller
2 GB available hard-disk space
1024 × 768
Mouse or a compatible pointing device
Microsoft ® Internet Explorer 7 or greater
A PXIe or PXI-H chassis peripheral slot
A Keysight embedded controller running one of the above operating systems.
Note: The embedded controller must be compatible with the Keysight chassis.
A desktop/laptop PC running one of the above operating systems and a Keysight interface cable
(e.g. Y1202) with PCIe (desktop) or ExpressCard (laptop) interface card.
[a] Because of the installation procedures, less memory may be required for the operation than is required for the installation.
24 Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Set up the controller
The following steps describe setting up the remote controller:
1 Install a compatible PCIe adapter in the PC.
2 Connect your I/O peripherals (mouse, keyboard, and monitor) to the PC.
3 Connect a compatible interface cable (e.g. Keysight Y1202) from the PC to the
PXIe chassis.
4 Power up the PXIe chassis.
5 Power up the PC and install the PCIe adapter drivers.
CAUTION
– During startup, power up the chassis before you power up the PC.
– During shutdown, power down the PC before you power down the chassis.
NOTE
The following steps describe setting up the embedded controller:
1 Install the embedded controller module into a compatible PXIe chassis.
2 Connect your I/O peripherals (mouse, keyboard, and monitor) to the embedded controller module.
3 Power up the PXIe chassis.
Do not install the M9260A module in the PXIe chassis yet. The software must be installed first to allow the Keysight IO Libraries Connection Expert software to detect the M9260A module.
Keysight M9260A Startup Guide 25
1 Inspection, Installation, and Verification
Install the software
Install the software for the M9260A PXIe Audio Analyzer. The latest software revision can be downloaded for free at www.keysight.com/find/M9260A .
The M9260A software consists of the following:
– Keysight IO Libraries Suite (IOLS), which includes the Keysight Connection
Expert.
– Soft Front Panel (SFP), device drivers (IVI-C,IVI-COM, LabVIEW G), and related user documentation for the M9260A.
NOTE
Every PXIe module comes with its own device driver (IVI-C, IVI-COM,
LabVIEW G), and soft front panel (SFP) software.
1 Download and launch the M9260A software installer.
2 Follow the installer prompts to install all software and documentation for the
M9260A PXIe Audio Analyzer.
26 Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Figure 1-2 InstallShield Wizard for Keysight M9260A
3 Once installation is complete, power down the PC and the PXIe chassis.
Keysight M9260A Startup Guide 27
1 Inspection, Installation, and Verification
Step 4: Install the Module
CAUTION
– The PXIe hardware does not support “hot-swapping” capabilities
(changing modules while power is applied to the chassis).
– Before installing the M9260A module into the chassis, ensure that the chassis is powered off and unplugged to prevent damage to the module.
NOTE
The M9260A module can be used in a chassis with a PXIe or PXI-H chassis peripheral slot.
The module can be installed in any PXIe slot marked with a peripheral slot compatibility image (a solid circle containing the slot number).
The module can also be installed in any hybrid PXI slot marked with a peripheral slot compatibility image (the letter “H” and a solid circle containing the slot number).
1 Ensure that the PXIe chassis power switch is at the Off (Standby) position and the chassis power cable is unplugged.
2 If the chassis has multiple fan speed settings, ensure that the fans are set to automatic. Do not set the fan speed to low or turn it off.
3 Position the chassis so that there is ample space between the chassis fan intake and exhaust vents. Blockage by walls or obstructions affect the air flow needed for cooling. (Refer to the chassis documentation for more information about cooling).
28 Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Figure 1-3 Installing the module to the chassis
4 Hold the module by the injector/ejector handle, and slide it into an available
PXIe or hybrid slot, as shown in
– Install the module into the PXIe slot of the chassis by placing the module card edges into the front module guides (top and bottom).
– Slide the module to the rear of the chassis and ensure that the injector/ ejector handle is pushed down in the unlatched (downward) position.
– Slide the module completely into the chassis.
– When you begin to feel resistance, push up on the injector/ejector handle to fully seat the module into the chassis.
5 Latch the module by pulling up on the injector/ejector handle and secure the front panel to the chassis using the module front-panel mounting screws.
6 Tighten the screws on the module front panel. Performance may suffer if the screws are not tightened properly.
Keysight M9260A Startup Guide 29
1 Inspection, Installation, and Verification
WARNING
7 Verify that the PXIe chassis fans are operable and free of dust that may restrict airflow.
8 Install all chassis covers and filler panels after installing the module. Missing filler panels may disrupt necessary air circulation in the chassis.
9 Plug in the power cable and power up the PXIe chassis.
Tighten the screws on the module front panel. Protection provided by the equipment could be impaired if the screws are not tightened properly.
30 Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Module installation procedures
1 Press down the ejector.
2 Slide the M9260A module into any slot until the backplane connectors touch.
3 Seat the M9260A module into the chassis by pulling up the ejector.
4 Tighten the top and bottom screws to secure the M9260A module to the chassis.
Figure 1-4 Module installation procedures
Keysight M9260A Startup Guide 31
1 Inspection, Installation, and Verification
M9260A front panel
32
Figure 1-5 M9260A PXIe Audio Analyzer front panel
Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
M9260A audio analyzer functional block diagram
Figure 1-6 M9260A functional block diagram
Keysight M9260A Startup Guide 33
1 Inspection, Installation, and Verification
Step 5: Verify the Operation of the M9260A Module
The purpose of the verification procedure for the M9260A is to ensure that the module is operating within its specifications.
The verification procedure is run using the M9260A Soft Front Panel (SFP) software included with this product. Launch the M9260A SFP by clicking its desktop shortcut icon or by clicking:
– Start > All Programs > Keysight M9260 PXIe Module > M9260 SFP
(Windows 7)
The M9260 SFP module selection interface will display all modules that are connected and installed. Review the configuration data and launch the M9260A
SFP.
The M9260A SFP will provide control over the module for operational verification
procedures. A screen capture of the SFP interface is shown in Figure 1-7 .
34
Figure 1-7 M9260A SFP interface
Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
NOTE
– The SFP can be used as a learning tool to help you experience the module's capability and behavior through an easy-to-use GUI.
– Refer to the Keysight M9260A Soft Front Panel Help for details on how to use the SFP software.
Conduct operational verification (optional)
The verification procedure in this section helps to ensure the M9260A module is operational. No external equipment is required except for two BNC to BNC cables to enable loopback configuration from the audio generator outputs to the audio analyzer inputs.
M9260A operational verification procedure
The M9260A verification procedure involves measuring the Vac, Frequency,
THD+N, and THD parameters. The average value from the measured data samples will then be calculated. The measurement results (average) are then compared to the known values output from the audio generator.
1 Launch the M9260A Soft Front Panel (SFP).
2 Connect the Generator CH1 output to the Analyzer CH1 input, and the
Generator CH2 output to the Analyzer CH2 input using BNC cables as shown in
Keysight M9260A Startup Guide 35
1 Inspection, Installation, and Verification
36
Figure 1-8 Connecting the BNC-BNC cables from the generator outputs to the analyzer inputs
3 Configure the M9260A PXIe Audio Analyzer using the SFP based on the settings in the following table and figures.
Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Table 1-2
Function
Analog Generator
Analog Analyzer
Measurement
Configuration for M9260A audio analyzer
Parameter
Channels
Impedance
Output
Waveform
Amplitude
Frequency
DC Offset
Channels
Range
Connection
Input
Impedance
Coupling
Sample Size
Sampling Rate
Function 1
Function 2
Function 3
Function 4
Low Pass Filter (LPF)
High Pass Filter (HPF)
Weighting
Setting
1 & 2 (Configure one channel at a time)
50 Ω
Differential
Sine
1 Vp
1 kHz
0 V
1 & 2 (Configure one channel at a time)
1 Vp
BNC
Differential
1 M Ω
DC
32768
192 kHz
AC
Frequency
THDN-Ratio
THD-Ratio
20 kHz
20 Hz
None
Keysight M9260A Startup Guide 37
1 Inspection, Installation, and Verification
Figure 1-9 Configuring the Analog Generator
38
Figure 1-10 Configuring the Analog Analyzer
Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Figure 1-11 Configuring the Measurement
4 On the Analog Generator tab, turn on the generator by clicking Generator: Off so that it becomes Generator: On .
5 On the Acquire section, select Continuous to initiate the audio analyzer to acquire data and perform the measurement. The results will be displayed under the Measurement Function Result section.
shows the
Acquire and Measurement Function Result section.
Figure 1-12 Initiating M9260A audio analyzer data acquisition
Keysight M9260A Startup Guide 39
1 Inspection, Installation, and Verification
6 Compare the measured values to the accuracy values as stipulated in
.
7 Repeat Step 3 to Step 6 using different output amplitude and input range
values for all voltage ranges and channels. Refer to Table 1-3 for the
suggested output amplitude and input range values.
Table 1-3
Output Amplitude
0.316 V
1 V
3.16 V
10 V
Operational verification table
Input Range
0.32 V
1 V
3.2 V
10 V
32 V
46 V
Measurement
Vac
Freq
THD+N
THD
Vac
Freq
THD+N
THD
Vac
Freq
THD+N
THD
Vac
Freq
THD+N
THD
Vac
Freq
THD+N
THD
Vac
Low Limit
0.2123 V
999.998 Hz
0.7000 V
999.998 Hz
2.2121 V
999.998 Hz
7.0004 V
999.998 Hz
7.0004 V
999.998 Hz
7.0004 V
< -110 dB
7.1418 V
1000.02 Hz
< -95 dB
< -105 dB
7.1418 V
High Limit
0.2346 V
1000.02 Hz
< -103 dB
< -110 dB
0.7142 V
1000.02 Hz
< -103 dB
< -110 dB
2.2568 V
1000.02 Hz
< -103 dB
< -110 dB
7.1418 V
1000.02 Hz
40 Keysight M9260A Startup Guide
Inspection, Installation, and Verification 1
Table 1-3
Output Amplitude
10 V
Operational verification table (continued)
Input Range
46 V
Measurement
Freq
THD+N
THD
Low Limit
999.998 Hz
High Limit
1000.02 Hz
8 If any of the values are out of range, refer to
service.
Keysight M9260A Startup Guide 41
1 Inspection, Installation, and Verification
42
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
Keysight M9260A Startup Guide
Keysight M9260A PXIe Audio Analyzer
Startup Guide
2 Characteristics and
Specifications
For the characteristics and specifications of the M9260A PXIe Audio Analyzer, refer to the datasheet at http://literature.cdn.keysight.com/litweb/pdf/5992-1918EN.pdf
.
43
2 Characteristics and Specifications
44
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
Keysight M9260A Startup Guide
This information is subject to change without notice. Always refer to the
Keysight website for the latest revision.
© Keysight Technologies 2017 - 2018
Edition 3, May 2018
Printed in Malaysia
*M9260-90000*
M9260-90000 www.keysight.com

Public link updated
The public link to your chat has been updated.
Advertisement