Stahl ET-xx7 Operating instructions
Stahl ET-xx7 is a line of high-performance HMI devices designed for use in hazardous areas. These devices offer a range of features that make them ideal for use in a variety of applications, including process control, monitoring, and data acquisition. Stahl ET-xx7 devices are available in a variety of configurations, including panel PCs, thin clients, and KVM systems. All devices are designed to meet the highest safety standards and are backed by Stahl's commitment to quality and reliability. With its rugged construction and advanced features, Stahl ET-xx7 is the perfect choice for demanding applications in hazardous areas.
Advertisement
Advertisement
Operating Instructions
Device platform MANTA
ET-xx7
SERIES 400 Panel PC
SERIES 500 Thin Clients
SERIES 600 KVM Systems
Doc. No.: 6000076
HW-Rev. ET-6x7:
HW-Rev. ET-4x7-*-BT:
HW-Rev. ET-5x7-*-BT:
HW-Rev. ET-4x7-*-P2:
HW-Rev. ET-5x7-*-P2:
Operating Instructions version:
Issue date:
Order number:
01.03.05
01.03.05
01.03.05
01.03.04
01.03.04
01.03.22
30.09.2021
296926
Operating Instructions ET-xx7 Disclaimer
Disclaimer
Publisher and copyright holder:
R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Köln
Telephone: (Sales Support)
Fax:
E-mail:
(Technical Support)
(Sales Support)
+49 221 768 06 - 1000
- 5000
- 4100 [email protected]
(Technical Support)
All rights reserved.
This document may not be reproduced in whole or in part except with the written consent of the publisher.
Subject to alterations.
Any warranty claims are limited to the right to demand amendments. Liability for any damage that might result from the contents of these instructions or all other documentation is limited to clear cases of premeditation.
We reserve the right to change our products and their specifications at any time, provided it is in the interest of technical progress. The information in the current manual (online or on CD / DVD
/ USB stick) or in the operating instructions included in the delivery applies.
Trademarks
The terms and names used in this document are registered trademarks and / or products of the companies in question.
Copyright © 2021 by R. STAHL HMI Systems GmbH. Subject to alterations
Page 2 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Specific markings Operating Instructions ET-xx7
Specific markings
The markings in these operating instructions refer to specific features that must be noted.
In detail, these are:
DANGER
This sign alerts users to hazards that will result in death or serious injury if ignored !
WARNING
This sign alerts users to hazards that may result in death or serious injury if ignored !
CAUTION
This sign alerts users to hazards that may damage machinery or equipment or result in injury if ignored !
ATTENTION
Information highlighted by this symbol indicates measures for the prevention of damage to machinery or equipment !
NOTICE
Information highlighted by this symbol indicates important information of which particular note should be taken !
DOCUMENTATION
Information highlighted by this symbol (with and without lettering) refers to a different chapter or section in this manual or other documentation or a web-page !
Warnings
Caution !
In ambient temperatures exceeding +45 °C the surface of the devices may heat up. Caution when touching !
Caution !
The laser diodes installed in our Exicom operator devices, media converters and switches emit invisible laser radiation:
100Base-FX - 1300 nm
FO-MM / 1000Base-SX - 770 … 860 nm
FO-SM / 1000Base-LX -
1270 … 1355 nm
Acc. to EN 60825-1 the laser diode is classified as a class 1M laser / Do not view directly with optical instruments. The viewing of the laser beam through certain optical instruments (e.g. magnifying glasses, telescopes and microscopes) from a distance of less than 100 mm may damage eyesight. (beam output at the emitting diode (TD-A, TD-B) or the fibre optic end).
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 3 of 92
Operating Instructions ET-xx7 Table of contents
Table of contents
Page 4 of 92
Description
Activation pressure touchscreen
ET-5x7 (SERIES 500 Thin Clients)
ET-6x7 (SERIES 600 KVM Systems)
Additionally for ET-4x7 (Panel PC)
All devices up to hardware revision 01.03.00
All devices starting from hardware revision 01.03.01
All devices starting from hardware revision 01.03.03
ET-477 devices starting from hardware revision 01.03.04
Additionally for ET-5x7 (Thin Clients)
All devices up to hardware revision 01.03.00
All devices starting from hardware revision 01.03.01
All devices starting from hardware revision 01.03.03
ET-577 devices starting from hardware revision 01.03.04
Resolution at ET-6x7 (KVM Systems) with DVI3
External, non-intrinsically safe circuits
External inherently safe optical interface
External intrinsically safe circuits
Page
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Table of contents Operating Instructions ET-xx7
Installation safety information
Only for HMI devices with DVI3 30
HMI installation in enclosures with degree of protection "e" or "t" 30
Conditions of safe use according to CEC / NEC / CSA 31
Safety information for operation
ET-4x7 (Panel PC) and ET-5x7 (Thin Client)
Up to Windows 7 operating systems
Note on Windows Embedded operating systems
Windows® 10 IoT Enterprise 2019 LTSC operating system
Company-specific Windows installations
Initial start-up ET-4x7 (Panel PC)
Repairs / hazardous substances
Disposal / Restricted substances
Declaration of substances and restricted substances
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Page 5 of 92
Operating Instructions ET-xx7
Control Drawing CEC / NEC / CSA
Mounting inside enclosure with ET-xx7 mounting-set
Table of contents
Page 6 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Preface Operating Instructions ET-xx7
1 Preface
These Operating Instructions contain all aspects relevant to explosion protection for the ET-xx7 devices - device platform MANTA - (SERIES 400 Open HMI - Panel PC´s, SERIES 500 Thin
Clients and SERIES 600 KVM Systems). They also contain information on the connection and installation (etc.) of these devices.
All data relevant to explosion protection from the EC-type examination certificate were copied into these operating instructions.
NOTICE
For the correct operation of all associated components please note, in addition to these operating instructions, all other operating instructions enclosed in this delivery as well as the operating instructions of the additional equipment to be connected !
DOCUMENTATION
Please note that all certificates of the HMI devices can be found in a separate document (CE_ET-xx7).
You can find this document in the internet at r-stahl.com
or request it from R. STAHL HMI Systems
GmbH.
2 Device function
The ET-xx7 units are explosion-protected equipment for installation in hazardous areas and can be operated in zones 1 and 21 with interfaces for zones 0/1/2 and 20/21/22.
The devices are connected to a communication system via the serial interfaces (RS-232,
Ethernet) located in their connection box at the rear. The connection box also contains the USB interfaces for the connection of various peripheral devices. Furthermore, the interfaces for keyboard, mouse, video and audio signals are also located here.
2.1 Image sticking
Continuous displaying fixed pattern may include image sticking. It’s recommended to use screen saver or moving content periodically if fixed pattern is displayed on the screen.
2.2 Processor types
All devices of 400 and 500 SERIES are fitted with modern, powerful processors. Depending on the type of application, different processor types are used for the HMI devices (see Technical
Data).
Starting in 2016, a new Intel® ATOM ™ processor type of the Bay Trail (BT) platform will gradually replace all previous processor types in the HMI devices, up from HW Revision
01.03.01. This new processor type processes data four times as fast as the previous processors.
In addition to the Bay Trail (BT) processor, the devices of 400 and 500 SERIES will be equipped with an AMD GX processor, up from HW Revision 01.03.04.
2.3 Activation pressure touchscreen
To prevent damage to the touchscreen, activation pressure on the screen with polyester foil must be very low (0.1 to max. 1 N) and on the screen with glass surface must be medium (1.8 to max. 2.5 N) !
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 7 of 92
Operating Instructions ET-xx7 Device function
2.4 ET-4x7 (SERIES 400 Panel PC)
The ET-4x7 HMI panel PCs are intelligent display and operating devices which can run any software and are thus easy to operate.
The devices are fitted with powerful processors and are thus able to process even large applications on-site. The devices have a back-up and recovery system which can be used to save complete images and load them onto new Panel PCs without requiring specific IT skills.
The X13 interface is provided for this purpose.
2.5 ET-5x7 (SERIES 500 Thin Clients)
The ET-5x7 devices of the 500 SERIES can be integrated into modern networks as Thin Clients or with a KVM box via KVM-over-IP. Digital Ethernet technology is used for the data transfer between KVM box and Remote System.
Up to four ET-5x7 devices can access one KVM box with one software license, thus costeffectively communicating with several PCs - for example, when monitoring the production process and simultaneously applying Condition Monitoring.
Multi-monitoring with several on-site terminals can as easily be implemented as the application as Thin Client in a server environment with virtual work stations.
2.6 ET-6x7 (SERIES 600 KVM Systems)
The KVM Classic transfer technology is used for the point-to-point connection between a PC and an ET-6x7 KVM device.
There are three versions (DVI1, DVI2 and DVI3) of this transfer technology that have slightly different functionality.
2.7 Overview hardware revision
HW-Rev. Device type
Changing date hardware
OI version
OI date
01.02.00 ET-xx7-*
01.03.00 ET-xx7-*
01.03.01
01.03.02
01.03.03
ET-4x7-*-BT-*
ET-5x7-*-BT-*
ET-4x7-*-BT-*
ET-5x7-*-BT-*
ET-4x7-*-BT-*
ET-5x7-*-BT-*
01.03.04
01.02.05
ET-4x7-*-P2-*
ET-5x7-*-P2-*
ET-4x7-*-BT-*
ET-5x7-*-BT-*
ET-4x7-*-BT-*
ET-5x7-*-BT-*
ET-6x7-*
Technical changing
Changing from T-Ex to ET-xx7
NEC / CEC approval
Bay Trail processor, quad core
SX with TX
M.2 memory
AMD processor
GX-222GC
BIOS update
BIOS-V1.63r4 no C6
Changing cable glands
01.01.2013
12.12.2014
01.07.2016
15.01.2018
14.06.2018
31.03.2019
29.06.2021
01.02.00 17.04.2013
01.03.00 08.01.2015
01.03.02 04.01.2016
01.03.09 21.12.2017
01.03.11 29.08.2018
01.03.21 27.09.2021
Page 8 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Type allocation Operating Instructions ET-xx7
3 Type allocation
Since the beginning of 2013, the T-series devices have been allocated new type names according to the following pattern:
To avoid having to re-write certifications, the names in the certificates remain the same, but the devices receive new names.
In the interest of a clear link between device type and certificate, both device names are listed on the type plate from 01.04.2013 onwards.
3.1 Type marking
Old (certificate)
T-Ex-##*-CAT7*-R2
T-Ex-##*-CAT7*-R2
New
ET-##7*-TX* / ET-##7-2TX*
ET-##7*-CAT*
T-Ex-##*-MM*-R2
T-Ex-##*-SM*-R2
ET-##7*-MM* / ET-##7-SX*
ET-##7*-SM* / ET-##7-LX*
* = alphanumeric or symbolic characters without relevance to explosion protection.
# = numeric character without relevance to explosion protection.
NOTICE
For the exact new device name and model please refer to the type code.
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 9 of 92
Operating Instructions ET-xx7 Technical data
4 Technical data
Function / Equipment
Display type
Display size
Resolution in pixels
Format
Viewing angle
Horizontal
Vertical
Display
Touchscreen (optional)
Backlight
Service life (MTBF) of backlight at
20 °C / 68 °F
Brightness
Contrast
Anti-reflective display
Touchscreen activation
Touchscreen input method
Touchscreen durability
Touchscreen scratch hardness MoHS
Touchscreen scratch hardness pencil hardness test ISO 15184
Touchscreen transmissivity / optics
Touchscreen surface contaminants
Touchscreen abrasive resistance
Additional keyboard (optional)
Power supply
Rated operational voltage AC
Voltage range AC
Frequency range
Rated operational voltage DC
Voltage range DC
Power
Current consumption AC
Current consumption DC
Connections
Recommended fuses
Max. operating voltage Um
ET-467
ET-567
ET-667
56 cm (22")
WSXGA+ 1680 x 1050
16:10 at CR ≥ 5
178°
170°
ET-477
ET-577
ET-677
TFT Color display
16.7 million colours
61 cm (24")
Full HD 1920 x 1080
16:9 at CR ≥ 5
178°
170°
Glass
Polyester foil or glass surface
5-wire analogue resistive
LED background lighting
Typically 50,000 h
ET-487
ET-587
ET-687
61 cm (24"WU)
WUXGA 1920 x 1200
16:10 at CR ≥ 10
178°
178°
250 cd/m² 300 cd/m²
1000 : 1
Devices without touchscreen: chemically coated
Devices with foil touchscreen: lightly anti-reflective (foil is abraded for slight milky effect)
Device with glass touchscreen: not anti-reflective, glass is too thin for chemical or mechanical treatment
Foil touch: low activation pressure (0.1 up to max. 1 N)
Glass touch: medium activation pressure (1.8 up to max. 2.5 N)
Finger, gloved finger or stylus
Foil touch: Polyester foil is easily scratched, with high pressure force the spacer dots could be damaged.
Glass touch: Quite good, but with high pressure force the spacer dots could be damaged.
Foil touch: -
Glass touch: >5
Foil touch: 3H
Glass touch: 9H
Foil touch: small milky effect due to the foil
Glass touch: very good
Unaffected
36 million times with a silicone rubber of R8 finger, hitting rate 250 g at 2 times per second
107 keys with integrated trackball / joystick / mouse pad or touch pad
Directly in the integrated Ex e connection box
230 V
100 - 240 V
50 - 60 Hz
24 V
20 - 30 V
Typically 50 W / 100 W at O30 / max. 150 W
(typically 170 BTU / 341 BTU at O30 / max. 510 BTU)
1 A
3 A via screw terminals, green
Flexible cable up to 2.5 mm² (AWG14)
Fixed cable up to 4 mm² (AWG12)
4 AT
250 VAC
Page 10 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Technical data Operating Instructions ET-xx7
Interfaces
Ethernet at ET-4x7 and ET-5x7
Optical fibre (SX)
Optical fibre (LX)
* Note optical fibre (SX and
LX) at ET-6x7
Copper (CAT)
Optical fibre (FO) (MM / SM)
USB
USB
Note on USB interfaces
Serial
Video in (optional)
Audio
Audio sound (optional)
Voltage output
** Note
Only for ET-4x7 and ET-5x7
Real-time clock
Data buffer
Battery
Capacitor
Cable type optical fibre
SX or MM
LX or SM
Data cable lengths
Optical fibre
SX or MM
LX or SM
Copper (TX)
Copper (CAT) for DVI1 for DVI2 for DVI3
Note CAT cable
Enclosure
Enclosure protection type
HMI Types
HMI Types comment
Cable glands
Type *
Number
Thread size
Cable diameter range
Width across flats
Mounting version keyboards
* Comment
* Comment a
Either copper or optical fibre * for information on copper, see sections 4.1 and 4.2
1000Base-SX, 1000 Mbit, multi-mode, intrinsically safe (Ex op is)
1000Base-LX, 1000 Mbit, single mode, intrinsically safe (Ex op is)
Up from HW-Rev. 01.03.02, all ET-4x7 and ET-5x7 devices with SX or LX Ethernet interface are fitted additional with an Ethernet 10/100/1000Base-TX interface !
Direct connection, Gigabit
Direct connection
2x Ex ia; 1x Ex e / USB 2.0, 480 Mbit/s for keyboard and mouse (Ex ia) / USB 2.0, 480 Mbit/s
The USB interfaces are based on USB 2.0. Due to explosion protection rules, the USB interface properties (such as speed or power supply) may be restricted.
RS-232, (Ex e)
FBAS (Ex e) (not AMD version)
Line out interface (Ex e) (Line in only at ET-6x7)
Audio amplifier (mono amplifier) 3.5 W, for 2x loudspeaker connection (Ex e)
(not AMD version)
12 VDC, max. 500 mA **
The voltage output has an internal fuse that cannot be replaced ! yes
Lithium battery and capacitor buffered, maintenance-free
> 5 years at least 4 days
Multi-mode optical fibre cable (50 µm core cross section and 125 µm external cross section)
Multi-mode optical fibre cable (62.5 µm core cross section and 125 µm external cross section)
Single mode optical fibre cable (9 µm core cross section and 125 µm external cross section) up to 550 m (1,804 ft) via 50/125 μm optical fibre cable up to 275 m (902 ft) via 62.5/125 μm optical fibre cable up to 10,000 m (33,000 ft) via 9/125 μm optical fibre cable up to 100 m (330 ft) via CAT7 installation cable AWG23 at 1x TX
2x up to 100 m (330 ft) via CAT7 installation cable AWG23 at 2TX up to 140 m (460 ft) via CAT7 installation cable AWG23 up to 500 m (1,640 ft) via CAT7 installation cable AWG23 up to 150 m (492 ft) via CAT7 installation cable AWG23
Minimum requirement is CAT5e, CAT7 recommended
Steel
Front IP66 / back IP65
PM = PanelMount = panel mount device
OS = Operator Station
Panel mount device (PM): devices without additional enclosure (HSG) and without additional accessories
Operator Station (OS): devices mounted inside additional enclosure (HSG)
HSK-M-Ex (Ex e)
2 x M16 / 1 x M20 / 3 x M25
M16 x 1.5 / M20 x 1.5 / M25 x 1.5
1x M16 = 4 … 8 mm / 1x M16 = 5 … 10 mm / M20 = 7 … 13 mm / M25 = 14 … 18 mm
M16 = SW20 / M20 = SW24 / M25 = SW30 when wiring KBDiUSB, use the cable glands 2x M16 4… 8 mm
(1x enclosed loose, exchange it for 1x M16 5… 10 mm) when wiring KB2, use the cable gland
1x M16 5… 10 mm (is pre-assembled)
Similar certified cable glands may be used.
Not used cable glands must be closed by certified screw plugs or stopping plugs !
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 11 of 92
Operating Instructions ET-xx7 Technical data
Permitted ambient temperature range
Operating temperature range
Cold start temperature *
Operation **
Operation with heater version O30 ***
Storage temperature range
* Note on cold start temperature
** Note on operation
*** Note on the O30 version
HMI Types comment OS
-30 °C … +60 °C / [-22 °F … +140 °F]
-10 °C / [+14 °F]
-20 °C … +60 °C / [-4 °F … +140 °F]
-30
°C … +60 °C / [-22 °F … +140 °F]
-30
°C … +70 °C / [-22 °F … +158 °F]
If the device is switched on in an ambient temperature of below -10 °C / [+14 °F], the display will require some time warming up before everything is clearly visible. Depending on how low the actual temperature is, this process may take up to 3 hours.
Operation at +60 °C / [+140 °F] for a maximum of 5 hours, at +50 °C / [+122 °F] for continuous operation (24/7)
The O30 version is only available for the AC version devices ! (not AMD version)
If the HMI device is installed in an additional enclosure (HSG), the upper temperature limit is reduced by 5 °C / [41 °F], due to the device's own heating and lower temperature dissipation in the additional enclosure !
Thus, the operator stations offers "only" an operation temperature range of
-20 °C … +55 °C / [-4 °F … +131 °F] !
Operating temperature range for DVI1
Cold start temperature
Operation
Storage temperature range
Heat dissipation
Relative humidity for DVI1
Environmental conditions
+5 °C [+41 °F]
+5
°C … +40 °C / [+41 °F … +104 °F]
-20
°C … +70 °C / [-4 °F … +158 °F]
About 40 % via the front plate and 60 % via the enclosure
10 to 90 % at +40 °C / [+104 °F], non-condensing
20 to 80 % at +40 °C / [+104 °F], non-condensing
Valid for all devices
Level Test specification
Damp heat (cyclic)
(only device with glass touch (TG))
Dry heat
+55 °C (±2 °C) ≥95 % IEC 60068-2-30 : 2005
+65 °C
IEC 60068-2-2 : 2007
IEC 60068-2-78 : 2012
Vibration (sinus) 5 up to 13.2 Hz: ±1 mm
13.2 up to 100 Hz: ±0.7 g
Sweep cycle 1 oct/min
Axis X, Y, Z
71.7 up to 79.2 Hz: ±0.7 g
120 min.
Sweep cycle 1 oct/min
Axis X
30 Hz: ±0.7 g
90 min.
Sweep cycle 1 oct/min
Axis Y, Z
IEC 60068-2-6 : 2008
IEC 60068-2-6 : 2008
Dwell test
Dimensions
Front (w x h)
Cut-out
(w x h) (+/-0.5 mm) (0.002")
Depth of cut-out
Wall thickness
Cut-out dimension for rear mount module
(w x h)
475.7 mm x 298.1 mm
660 mm x 475 mm (25.98” x 18.70”)
615 mm x 435 mm (24.21” x 17.13”)
110 mm (4.33")
≤5 mm (0.02")
523 mm x 295 mm
(18.73" x 11.74")
Mounting position
Weight
4.1 Additionally for ET-4x7 (Panel PC)
(20.59" x 11.61")
Vertical or horizontal
32.00 kg (70.55 lbs)
520.4 mm x 326 mm
(20.49" x 12.83")
4.1.1 All devices up to hardware revision 01.03.00
Processor
RAM
Data memory
Type of data memory
Operating system
Global language support
Interface copper (TX)
Intel ATOM N270; 1.6 GHz
1 or 2 GB
4 or 16 GB
128 GB MLC
128 GB SLC
Flash memory (SATA)
Windows XP Embedded / Windows XP Professional / Windows 7 Ultimate (32 bit)
Via Multi-Language interface of Windows XP Embedded (25 languages)
1x 10/100Base-TX, 10/100 Mbit (Ex e)
Page 12 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Technical data Operating Instructions ET-xx7
4.1.2 All devices starting from hardware revision 01.03.01
Processor
RAM
Data memory
Type of data memory
Graphics controller
Operating system
Global language support
Interface copper (TX)
Note copper
Intel Bay Trail (BT) ATOM E3845 Quad Core; 1.91 GHz
4 GB
Size
64 GB MLC
TBW
18.75
Test profile
JESD218 Client profile
128 GB MLC 37.5
Flash memory (Solid state drive - SSD) (internal via CF-Slot)
Integrated Intel Gen. 7 HD Graphics
Windows Embedded Standard 7 (64 bit) / Windows 7 Ultimate (64 bit)
Via Windows operating system
1x 10/100Base-TX, 10/100 Mbit (Ex e) or
2x 10/100Base-TX, 10/100 Mbit (Ex e)
If the customer installs an operation system, the driver for the "USB-SK-LAN-Adapter" must be installed. For this, please contact [email protected]
.
(Driver is part of STAHL images)
4.1.3 All devices starting from hardware revision 01.03.03
Type of data memory
Operating system
Flash memory M.2 (Solid State Drive - SSD) (internal via SATA)
Windows 10 IoT Enterprise (64 bit) (included in standard delivery)
Windows 10 IoT Enterprise (32 bit) (optional on USB stick)
4.1.4 ET-477 devices starting from hardware revision 01.03.04
Processor type
Processor details
Graphics controller
Interface copper (TX)
AMD GX-222GC
2.2 GHz; Dual Core, 10W TDP i ntegrated AMD Radeon R5E graphics
1x 10/100Base-TX, 10/100 Mbit (Ex e) or
2x 10/100Base-TX, 10/100 Mbit (Ex e)
4.2 Additionally for ET-5x7 (Thin Clients)
4.2.1 All devices up to hardware revision 01.03.00
Processor
RAM
Data memory
Operating system
Interface copper (TX)
NOTICE
AMD Geode LX 800; 266 MHz
512 MB
2 GB *
1 GB
16 GB *
Windows Embedded Standard 2009 and Remote Firmware
Windows Embedded Standard 7, Remote Firmware and Delta V *
1x 10/100Base-TX, 10/100 Mbit (Ex e)
* The combination of 2 GB RAM with 16 GB data memory is only available for the operating system with Delta V !
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 13 of 92
Operating Instructions ET-xx7 Technical data
4.2.2
Processor
RAM
Data memory
Type of data memory
Graphics controller
Operating system
Interface copper (TX)
Note copper
All devices starting from hardware revision 01.03.01
Size
Intel Bay Trail (BT) ATOM E3845 Quad Core; 1,91 GHz
4 GB
64 GB MLC
TBW
18.75
Test profile
JESD218 Client profile
128 GB MLC 37.5
Flash memory (SATA)
Integrated Intel Gen. 7 HD Graphics
Windows 10 IoT Enterprise and Remote Firmware
1x 10/100Base-TX, 10/100 Mbit (Ex e) or
2x 10/100Base-TX, 10/100 Mbit (Ex e)
If the customer installs an operation system, the driver for the "USB-SK-LAN-Adapter" must be installed. For this, please contact [email protected]
.
(Driver is part of STAHL images)
4.2.3 All devices starting from hardware revision 01.03.03
Type of data memory
4.2.4
Flash memory M.2 (Solid State Drive - SSD) (internal via SATA)
ET-577 devices starting from hardware revision 01.03.04
Processor type
Processor details
Graphics controller
Interface copper (TX)
AMD GX-222GC
2.2 GHz; Dual Core, 10W TDP i ntegrated AMD Radeon R5E graphics
1x 10/100Base-TX, 10/100 Mbit (Ex e) or
2x 10/100Base-TX, 10/100 Mbit (Ex e)
4.3 Resolution at ET-6x7 (KVM Systems) with DVI3
Function / Equipment
Resolution in pixels
ET-667
1680 x 1050
1280 x 1024
1280 x 960
1152 x 864
1024 x 768
800 x 600
ET-677
1920 x 1080
1600 x 1200
1600 x 1000
1400 x 1050
1360 x 768
1280 x 1024
1280 x 920
1280 x 800
1152 x 864
1024 x 768
800 x 600
ET-687
1920 x 1200
1920 x 1080
1680 x 1050
1600 x 1200
1280 x 1024
1280 x 960
1280 x 800
1152 x 864
1024 x 768
800 x 600
Page 14 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Conformity to standards Operating Instructions ET-xx7
5 Conformity to standards
The ET-xx7 devices comply with the following standards and directive:
Standard
2. Supplement
Classification
ATEX directive 2014/34/EU
EN 60079-0 : 2009
EN 60079-5 : 2007
EN 60079-7 : 2007
General requirements
Powder filling "q"
Increased safety "e"
EN 60079-11 : 2007
EN 60079-26 : 2007
EN 60079-28 : 2004
EN 60079-31 : 2009
Intrinsic safety "i"
Device protection (EPL) "Ga"
Optical radiation
Protected by enclosures "tD" (dust)
EN 61241-11 : 2006 Intrinsic safety "iD" (dust)
The product corresponds to requirements from:
EN 60079-0 : 2012 + A11 : 2013
EN IEC 60079-0 : 2018
EN 60079-5 : 2015
EN 60079-7 : 2015
EN IEC 60079-7 : 2015 + A1 : 2018
General requirements
Powder filling "q"
Increased safety "e"
EN 60079-11 : 2012
EN 60079-26 : 2015
EN 60079-28 : 2016
EN 60079-31 : 2014
Intrinsic safety "i"
Device protection (EPL) "Ga"
Optical radiation
Protected by enclosures "tD" (dust)
Electromagnetic compatibility
EMV directive
2014/30/EU
EN 61000-6-2 : 2006
EN 61000-6-4 : 2007
EN 61010-1 : 2001+
EN 62368-1 : 2016
IEC 62368-1 : 2014
Classification
Interference resistance
Interference emission
Low voltage directive
Directive 2014/35/EU
General requirements
Audio / video, information and communication technology equipment - Safety requirements
RoHS directive
2011/65/EU
EN IEC 63000 : 2018
Classification
Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 15 of 92
Operating Instructions ET-xx7 Conformity to standards
5.1 CEC / NEC / CSA
Standard
CAN/CSA-C22.2 No. 0-10
August 2011
CAN/CSA-C22.2 No. 61010-1-12
CAN/CSA-C22.2 No. 60079-0 : 11
(December 2011)
CAN/CSA-C22.2 No. 60079-5 : 11
(December 2011)
CAN/CSA-C22.2 No. 60079-7 : 12
(February 2012)
CAN/CSA-C22.2 No. 60079-11 : 11
(December 2011)
CAN/CSA-C22.2 No. 60529:05
(Reaffirmed 2010)
ANSI/UL 61010-1
(2012)
ANSI/UL 60079-0
(sixth edition July 2013)
ANSI/UL 60079-5
(third edition November 2013)
ANSI/UL 60079-7
(fourth edition May 2013)
ANSI/UL 60079-11
(sixth edition March 2014)
ANSI/IEC 60529-2004
Classification
General requirements
Canadian Electrical Code, Part II
Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory
Use - Part 1: General Requirements
(Third Edition)
Explosive atmospheres
– Part 0: Equipment
General requirements
Explosive atmospheres – Part 5: Equipment protection by powder filling “q”
Explosive atmospheres – Part 7: Equipment protection by increased safety “e”
Explosive atmospheres – Part 11: Equipment protection by intrinsic safety “i”
Degrees of protection provided by enclosures
(IP Code)
Electrical Equipment for Measurement,
Control, and Laboratory Use - Part 1: General
Requirements (Third Edition)
Explosive atmospheres –
Part 0: Equipment – General requirements
Explosive atmospheres –
Part 5: Equipment protection by powder filling “q”
Explosive atmospheres
–
Part 7: Equipment protection by increased safety “e”
Explosive atmospheres –
Part 11: Equipment protection by intrinsic s afety “i”
Degrees of protection provided by enclosures
(IP code)
5.2 Mounting inside enclosure
The ET-xx7 devices can be mounted in an enclosure with suitable cut-out using an mounting kit.
This mounting kit is approved for mounting in an Ex e, Ex p or Ex tb protected enclosure and consist of a sealing fixed at the HMI device and 24 nuts.
The assembly is shown in drawing “10410300 T-Ex - xx7 Mounting Assembly Overview”.
The sealing must be in correct position and must not be damaged.
The nuts must be mounted with a torque of 1.0 Nm ... 1.4 Nm.
Page 16 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Certificates Operating Instructions ET-xx7
6 Certificates
The ET-xx7 devices are certified for installation in the following areas:
Synonym Scope Certificate number
CE / ATEX Europe BVS 11 ATEX E 102 X
IECEx
EAC
NEC
CEC
Global
Russia
USA
Canada
IECEx BVS 11.0075X
TC RU C-DE.HA91.B.00166/20
CSA 70011698
PESO
CCE
India
A/P/HQ/TN/104/5768 (P438244)
P438244/1
KCC
KGS
CCC
CNEX
RCM
DNV / GL
Korea
China
Australia
Marine- / ship certification
12-GA4BO-0617X
2021312309000500
CNEx21.1938X
TAA00000BK
Comment see notice CEC
Identification number
Device restriction see notice
KCC
According to declaration of conformity
Device restriction see notice
DNV / GL
DOCUMENTATION
You can access all IECEx certificates on the official website of the IEC under their certificate number. http://iecex.iec.ch/iecex/iecexweb.nsf/welcome?openform
.
NOTICE
Note CEC:
The HMIs are certified according to Ex e q [ia] IIC T4 Gb.
According to the CEC Part 1 each device with these protection types may be operated in Class I, Division 2 areas.
For more details on this, please refer to the CEC.
NOTICE
Note KCC:
In order to be able to operate these HMI devices in Korea, each device type additionally requires a KCC certificate.
Actually the following devices has such a certificate:
T-Ex-22 (ET-x67), T-Ex-22-DVI3 (ET-667-DVI3), T-Ex-24T (ET-x77 with touch screen (foil))
NOTICE
Note DNV / GL:
Only the HMI devices type:
ET-667-DVI3-yM-FO-TFT-TG-AC-O30-AL
ET-677-DVI3-yM-FO-TFT-TG-AC-O30-AL
ET-687-DVI3-yM-FO-TFT-TG-AC-O30-AL have DNV / GL certification! with y: M = FO direct connection multi-mode
S = FO direct connection single mode
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 17 of 92
Operating Instructions ET-xx7 Marking
6.1 FSB notification
The FSB notification of the MANTA field systems can be reviewed under this link: https://portal.eaeunion.org/sites/odata/_layouts/15/Portal.EEC.Registry.Ui/DirectoryForm.aspx?ViewId=859e c98d-f4fe-423a-b6bc-d01b53fd4b7c&ListId=0e3ead06-5475-466a-a340-
6f69c01b5687&ItemId=232#f=STAHL
7 Marking
Manufacturer
Type code
CE classification:
Testing authority and certificate number:
Ex classification:
ATEX
IECEx
EAC
NEC
R. STAHL HMI Systems GmbH
ET-4x7 / ET-5x7 / ET-6x7 c
0158
BVS 11 ATEX E 102 X
CEC
PESO
KGS
CCC / CNEX e
II 2(1) G Ex eb q [ia op is Ga] IIC T4 Gb
II 2(1) D Ex tb IIIC [ia op is Da] IP65 T110°C Db
Ex eb q [ia op is Ga] IIC T4 Gb
Ex tb IIIC [ia op is Da] IP65 T110°C Db
1Ex e q [ia op is Ga] IIC T4 Gb X
Ex tb IIIC [ia op is Da] T110°C Db X
Class I, Zone 1 AEx e q [ia] IIC T4 Gb
Class I, Division 2, Groups A, B, C, D
(according to NEC 501.5)
Ex e q [ia] IIC T4 Gb
Class I, Division 2, Groups A, B, C, D
(according to CEC J18-150)
Ex eb q [ia op is Ga] IIC T4 Gb
Ex e q IIC T4
Ex tb IIIC IP64 T110°C
Ex ia IIC T4
Ex ia IIIB T110°C
Ex e q [ia op is Ga] IIC T4 Gb
Ex tD [iaD op is] A21 IP65 T110°C
Page 18 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Power supply Operating Instructions ET-xx7
8 Power supply
8.1 HMI devices
Power supply: 24 VDC or 100 – 240 VAC, 50 – 60 Hz max. power consumption: at 24 VDC at 100 - 240 VAC max. 3 A max. 1 A
9 Permitted maximum values
9.1 External, non-intrinsically safe circuits
Input voltage “PWR” (X10):
Nominal voltage:
Power consumption I max
Power P max
Max. operating voltage U m
Short-circuit current I
K
USB (X13):
Rated voltage
Max. operating voltage U m
12 V (X14):
Rated voltage
Power consumption Imax
Max. operating voltage U m
RS-232 "SER" (X97):
20 ...240 VAC/VDC (depending on type)
≤ 5 A
≤ 150 W
≤ 250 VAC
≤ 1500 A
5 VAC/VDC (±10 %)
≤ 250 VAC
12 VAC/VDC (±10 %)
≤ 400 mA
≤ 250 VAC
Rated voltage
Max. operating voltage U m
Video "CAM" (X101):
Rated voltage
Max. operating voltage U m
Audio "AUD" (X105):
15 VAC/VDC (±10 %)
≤ 250 VAC
5 VAC/VDC (±10 %)
≤ 250 VAC
Rated voltage
Max. operating voltage U m
Copper Ethernet (CAT7 1) (X16):
Rated voltage
Max. operating voltage U m
100 VAC/VDC (±10 %)
≤ 250 VAC
5 VAC/VDC (±10 %)
≤ 250 VAC
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 19 of 92
Operating Instructions ET-xx7 Permitted maximum values
9.2 External inherently safe optical interface
Ethernet optical fiber (FO 1) (X18)
Multi-mode
Wavelength
Radiant power max. radiant power:
850 nm
0.22 mW
35 mW
Single mode
Wavelength
Radiant power max. radiant power:
1310 nm
0.22 mW
35 mW
9.3 External intrinsically safe circuits
Keyboard (X11)
The maximum values are:
U
I i i
P i
C i
L i
=
=
=
5.5
3
2
= negligible
= negligible
V
A
W
µF mH
Pointer device (X12):
The maximum values are:
U i
I i
P i
C i
L i
=
=
=
5.5
3
2
= negligible
= negligible
V
A
W
µF mH
USB1i (X24):
The maximum values are:
U i
I i
P i
C i
L i
=
=
=
5.5
3
2
= negligible
= negligible
V
A
W
µF mH
USB2i (X25):
The maximum values are:
U i
= 5.5
I i
P i
=
=
3
2
C i
L i
V
A
W
= negligible µF
= negligible mH
U o
= 5.5 l o
= 309
P o
= 629
C o
= 50
L o
= 40
U o
= 5.5 l o
= 309
P o
= 629
C o
= 50
L o
= 40
U o
= 5.5 l o
= 309
P o
= 629
C o
= 50
L o
= 40
U o
= 5.5 l o
= 309
P o
= 629
C o
= 50
L o
= 40
V mA mW
µF
µH
V mA mW
µF
µH
V mA mW
µF
µH
V mA mW
µF
µH
Page 20 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Type code Operating Instructions ET-xx7
10 Type code
10.1 ET-4x7 (Panel PC)
NOTICE
These versions apply to all Panel PC's up to hardware revision
01.03.00, with ATOM N270 processor.
ET-4x7-aa-bb-cc-dd-ee-ff-gg-hh
Device variant:
Classification product key
ET-4x7SX -bb-cc-dd-ee-ff-gg-hh
ET-4x7TX
ET-4x7-aa-
-bb-cc-dd-ee-ff-gg-hh
TFT
ET-4x7-aa-bbT
-cc-dd-ee-ff-gg-hh
-dd-ee-ff-gg-hh
ET-4x7-aa-bbTG -dd-ee-ff-gg-hh
ET-4x7-aa-bb-ccR1 -ee-ff-gg-hh
ET-4x7-aa-bb-ccR2 -ee-ff-gg-hh
ET-4x7-aa-bb-cc-dd4GB -ff-gg-hh
ET-4x7-aa-bb-cc-dd16GB -ff-gg-hh
ET-4x7-aa-bb-cc-dd128GBM -ff-gg-hh
ET-4x7-aa-bb-cc-dd128GBS -ff-gg-hh
Front design
Outdoor option
Voltage supply
Data memory
RAM
Touch screen
Display type
Ethernet interface
467 / 477 / 487 middle digit = display size
6 = 56 cm / 22" display
7 = 61 cm / 24" display
8 = 61 cm / 24"WU display
Description
Type with
Optical fiber Ethernet interface 1000Base-SX
(Ex op is), multi-mode
Copper Ethernet interface 10/100Base-TX (Ex e)
TFT display (standard)
Touch screen (membrane)
Touch screen glass
1 GB RAM
2 GB RAM
4 GB Solid State Drive
16 GB Solid State Drive
128 GB Solid State Drive MLC
128 GB Solid State Drive SLC
100 GB hard disk (internal) ET-4x7-aa-bb-cc-dd100GB -ff-gg-hh
ET-4x7-aa-bb-cc-dd-eeAC -gg-hh
ET-4x7-aa-bb-cc-dd-eeDC -gg-hh
ET-4x7-aa-bb-cc-dd-ee-ffO30 -hh
ET-4x7-aa-bb-cc-dd-ee-ff-ggAL
ET-4x7-aa-bb-cc-dd-ee-ff-ggRM
Power supply 100 - 240 VAC, 50 - 60 Hz
Voltage supply 24 VDC
Outdoor installation -30 °C [-22 °F] *
Aluminium front plate
Rear mount module
NOTICE * The O30 option is only available for AC devices !
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 21 of 92
Operating Instructions ET-xx7 Type code
10.2 ET-4x7-*-BT (Panel PC)
NOTICE
These versions apply to all Panel PC's starting from hardware revision 01.03.01, with Bay Trail ATOM E3845 processor.
ET-4x7-aa-BT-bb-cc-dd-ee-ff-gg-hh-ii
Device variant:
Classification product key
ET-4x7SX -BT-bb-cc-dd-ee-ff-gg-hh-ii
Front design
Outdoor option
Voltage supply
Audio
Data memory
RAM
Touch screen
Display type
Processor type (fixed to BT = Bay Trail)
Ethernet interface
467 / 477 / 487 middle digit = display size
6 = 56 cm / 22" display
7 = 61 cm / 24" display
8 = 61 cm / 24"WU display
ET-4x7LX -BT-bb-cc-dd-ee-ff-gg-hh-ii
ET-4x7TX -BT-bb-cc-dd-ee-ff-gg-hh-ii
ET-4x72TX -BT-bb-cc-dd-ee-ff-gg-hh-ii
ET-4x7-aa-BTTFT -cc-dd-ee-ff-gg-hh-ii
ET-4x7-aa-BT-bbT -dd-ee-ff-gg-hh-ii
ET-4x7-aa-BT-bbTG -dd-ee-ff-gg-hh-ii
ET-4x7-aa-BT-bb-ccR3 -ee-ff-gg-hh-ii
ET-4x7-aa-BT-bb-cc-dd64GB -ff-gg-hh-ii
ET-4x7-aa-BT-bb-cc-dd128GB -ff-gg-hh-ii
ET-4x7-aa-BT-bb-cc-dd-eeSND -gg-hh-ii
ET-4x7-aa-BT-bb-cc-dd-ee-ffAC -hh-ii
ET-4x7-aa-BT-bb-cc-dd-ee-ffDC -hh-ii
ET-4x7-aa-BT-bb-cc-dd-ee-ff-ggO30 -ii
ET-4x7-aa-BT-bb-cc-dd-ee-ff-gg-hhAL
ET-4x7-aa-BT-bb-cc-dd-ee-ff-gg-hhRM
NOTICE
Description
Type with
Optical fiber Ethernet interface 1000Base-SX
(Ex op is), multi-mode
Additional with 1x copper Ethernet interface
10/100/1000Base-TX up from HW-Rev. 01.03.02
Optical fiber Ethernet interface 1000Base-LX
(Ex op is), single mode
Additional with 1x copper Ethernet interface
10/100/1000Base-TX up from HW-Rev. 01.03.02
Copper Ethernet interface 10/100Base-TX
(Ex e)
2x Copper Ethernet interface 10/100Base-TX
(Ex e)
TFT display (standard)
Touch screen (membrane)
Touch screen glass
4 GB RAM
64 GB Solid State Drive
128 GB Solid State Drive
Audio amplifier (mono amplifier) 3.5 W
Power supply 100 - 240 VAC, 50 - 60 Hz
Voltage supply 24 VDC
Outdoor installation -30 °C [-22 °F] *
Aluminium front plate
Rear mount module
* The O30 option is only available for AC devices !
Page 22 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Type code Operating Instructions ET-xx7
10.3 ET-477-*-P2 (Panel PC)
NOTICE
ET-477-aa-P2-bb-cc-dd-ee-ff-gg-hh-ii
Device variant:
Classification product key
ET-4772TX -P2-bb-cc-dd-ee-ff-gg-hh-ii
ET-477-
ET-477-
SX
LX
These versions apply to all Panel PC's starting from hardware revision 01.03.04, with AMD GX processor.
-P2-bb-cc-dd-ee-ff-gg-hh-ii
-P2-bb-cc-dd-ee-ff-gg-hh-ii
ET-477-aa-P2TFT
ET-477-aa-P2-bb-
ET-477-aa-P2-bb-
T
-cc-dd-ee-ff-gg-hh-ii
-dd-ee-ff-gg-hh-ii
TG -dd-ee-ff-gg-hh-ii
ET-477-aa-P2-bb-ccR3 -ee-ff-gg-hh-ii
ET-477-aa-P2-bb-cc-dd64GB -ff-gg-hh-ii
ET-477-aa-P2-bb-cc-dd128GB
ET-477-aa-P2-bb-cc-dd-ee-ff-
ET-477-aa-P2-bb-cc-dd-ee-ff-
-ff-gg-hh-ii
AC
DC
-hh-ii
-hh-ii
ET-477-aa-P2-bb-cc-dd-ee-ff-gg-hhAL
Front design
Outdoor option
Voltage supply
Audio
Processor type (P2 = AMD GX)
7
(unavailable)
Data memory
RAM
Touch screen
Display type middle digit
=
=
(unavailable)
Ethernet interface
display size
61 cm / 24" display
Description
Type with
2x Copper Ethernet interface 10/100Base-TX
(Ex e)
Optical fiber Ethernet interface 1000Base-SX
(Ex op is), multi-mode, additional 1x copper Ethernet interface
10/100/1000Base-TX
Optical fiber Ethernet interface 1000Base-LX
(Ex op is), single mode, additional 1x copper Ethernet interface
10/100/1000Base-TX
TFT display (standard)
Touch screen (membrane)
Touch screen glass
4 GB RAM
64 GB Solid State Drive
128 GB Solid State Drive
Power supply 100 - 240 VAC, 50 - 60 Hz
Voltage supply 24 VDC
Aluminium front plate
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 23 of 92
Operating Instructions ET-xx7 Type code
10.4 ET-5x7 (Thin Client)
NOTICE
These versions apply to all Thin Client's up to hardware revision
01.03.00, with AMD Geode LX processor.
ET-5x7-aa-bb-cc-dd-ee-ff
Device variant:
Classification product key
ET-5x7SX -bb-cc-dd-ee-ff
Front design
Outdoor option
Voltage supply
Touch screen
Display type
Ethernet interface
567 / 577 / 587 middle digit = display size
6 = 56 cm / 22" display
7
8
=
=
61 cm / 24" display
61 cm / 24"WU display
Description
Type with
Optical fiber Ethernet interface 1000Base-SX (Ex op is), multi-mode
Copper Ethernet interface 10/100Base-TX (Ex e)
TFT display (standard)
ET-5x7TX -bb-cc-dd-ee-ff
ET-5x7-aaTFT -cc-dd-ee-ff
ET-5x7-aa-bbT -dd-ee-ff
ET-5x7-aa-bbTG -dd-ee-ff
ET-5x7-aa-bb-ccAC -ee-ff
ET-5x7-aa-bb-ccDC -ee-ff
ET-5x7-aa-bb-cc-ddO30 -ff
ET-5x7-aa-bb-cc-dd-eeAL
ET-5x7-aa-bb-cc-dd-eeRM
Touch screen (membrane)
Touch screen glass
Power supply 100 - 240 VAC, 50 - 60 Hz
Voltage supply 24 VDC
Outdoor installation -30 °C [-22 °F] *
Aluminium front plate
Rear mount module
NOTICE * The O30 option is only available for AC devices !
Page 24 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Type code Operating Instructions ET-xx7
10.5 ET-5x7-*-BT (Thin Client)
NOTICE
These versions apply to all Thin Client's starting from hardware revision 01.03.01, with Bay Trail ATOM E3845 processor.
ET-5x7-aa-BT-bb-cc-dd-ee-ff-gg-hh-ii
Device variant:
Classification product key
ET-5x7SX -BT-bb-cc-dd-ee-ff-gg-hh-ii
Front design
Outdoor option
Voltage supply
Audio
Data memory
RAM
Touch screen
Display type
Processor type (fixed to BT = Bay Trail)
Ethernet interface
567 / 577 / 587 middle digit = display size
6 = 56 cm / 22" display
7 = 61 cm / 24" display
8 = 61 cm / 24"WU display
ET-5x7LX -BT-bb-cc-dd-ee-ff-gg-hh-ii
ET-5x7TX -BT-bb-cc-dd-ee-ff-gg-hh-ii
ET-5x72TX -BT-bb-cc-dd-ee-ff-gg-hh-ii
ET-5x7-aa-BTTFT -cc-dd-ee-ff-gg-hh-ii
ET-5x7-aa-BT-bbT -dd-ee-ff-gg-hh-ii
ET-5x7-aa-BT-bbTG -dd-ee-ff-gg-hh-ii
ET-5x7-aa-BT-bb-ccR3 -ee-ff-gg-hh-ii
ET-5x7-aa-BT-bb-cc-dd64GB -ff-gg-hh-ii
ET-5x7-aa-BT-bb-cc-dd128GB -ff-gg-hh-ii
ET-5x7-aa-BT-bb-cc-dd-eeSND -gg-hh-ii
ET-5x7-aa-BT-bb-cc-dd-ee-ffAC -hh-ii
ET-5x7-aa-BT-bb-cc-dd-ee-ffDC -hh-ii
ET-5x7-aa-BT-bb-cc-dd-ee-ff-ggO30 -ii
ET-5x7-aa-BT-bb-cc-dd-ee-ff-gg-hhAL
ET-5x7-aa-BT-bb-cc-dd-ee-ff-gg-hhRM
NOTICE
Description
Type with
Optical fiber Ethernet interface 1000Base-SX
(Ex op is), multi-mode
Additional with 1x copper Ethernet interface
10/100/1000Base-TX up from HW-Rev. 01.03.02
Optical fiber Ethernet interface 1000Base-LX
(Ex op is), single mode
Additional with 1x copper Ethernet interface
10/100/1000Base-TX up from HW-Rev. 01.03.02
Copper Ethernet interface 10/100Base-TX
(Ex e)
2x Copper Ethernet interface 10/100Base-TX
(Ex e)
TFT display (standard)
Touch screen (membrane)
Touch screen glass
4 GB RAM
64 GB Solid State Drive
128 GB Solid State Drive
Audio amplifier (mono amplifier) 3.5 W
Power supply 100 - 240 VAC, 50 - 60 Hz
Voltage supply 24 VDC
Outdoor installation -30 °C [-22 °F] *
Aluminium front plate
Rear mount module
* The O30 option is only available for AC devices !
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 25 of 92
Operating Instructions ET-xx7 Type code
10.6 ET-577-*-P2 (Thin Client)
NOTICE
ET-577-aa-P2-bb-cc-dd-ee-ff-gg-hh-ii
Device variant:
Classification product key
ET-5772TX -P2-bb-cc-dd-ee-ff-gg-hh-ii
ET-577-
ET-577-
SX
LX
These versions apply to all Thin Client's starting from hardware revision 01.03.04, with AMD GX processor.
-P2-bb-cc-dd-ee-ff-gg-hh-ii
-P2-bb-cc-dd-ee-ff-gg-hh-ii
ET-577-aa-P2TFT
ET-577-aa-P2-bb-
ET-577-aa-P2-bb-
T
-cc-dd-ee-ff-gg-hh-ii
-dd-ee-ff-gg-hh-ii
TG -dd-ee-ff-gg-hh-ii
ET-577-aa-P2-bb-ccR3 -ee-ff-gg-hh-ii
ET-577-aa-P2-bb-cc-dd64GB -ff-gg-hh-ii
ET-577-aa-P2-bb-cc-dd128GB -ff-gg-hh-ii
ET-577-aa-P2-bb-cc-dd-ee-ffAC -hh-ii
ET-577-aa-P2-bb-cc-dd-ee-ffDC -hh-ii
ET-577-aa-P2-bb-cc-dd-ee-ff-gg-hhAL
Front design
Outdoor option
Voltage supply
Audio
Processor type (P2 = AMD GX)
7
(unavailable)
Data memory
RAM
Touch screen
Display type middle digit
=
=
(unavailable)
Ethernet interface
display size
61 cm / 24" display
Description
Type with
2x Copper Ethernet interface 10/100Base-TX
(Ex e)
Optical fiber Ethernet interface 1000Base-SX
(Ex op is), multi-mode, additional 1x copper Ethernet interface
10/100/1000Base-TX
Optical fiber Ethernet interface 1000Base-LX
(Ex op is), single mode, additional 1x copper Ethernet interface
10/100/1000Base-TX
TFT display (standard)
Touch screen (membrane)
Touch screen glass
4 GB RAM
64 GB Solid State Drive
128 GB Solid State Drive
Power supply 100 - 240 VAC, 50 - 60 Hz
Voltage supply 24 VDC
Aluminium front plate
Page 26 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Type code Operating Instructions ET-xx7
10.7 ET-6x7 KVM System
ET-6x7-aa-bb-cc-dd-ee-ff-gg
Device variant:
Classification product key
ET-6x7DVI1-CAT -bb-cc-dd-ee-ff-gg
Front design
Outdoor option
Voltage supply
Audio
Touch screen
Display type
Transfer technology
667 / 677 / 687 middle digit = display size
6 = 56 cm / 22" display
7 = 61 cm / 24" display
8 = 61 cm / 24"WU display
ET-6x7DVI1-MM -bb-cc-dd-ee-ff-gg
ET-6x7DVI1-SM -bb-cc-dd-ee-ff-gg
ET-667DVI2-CAT -bb-cc-dd-ee-ff-gg
ET-6x7DVI3-CAT -bb-cc-dd-ee-ff-gg
ET-6x7DVI3-MM-FO -bb-cc-dd-ee-ff-gg
ET-6x7DVI3-SM-FO -bb-cc-dd-ee-ff-gg
ET-6x7-aaTFT -cc-dd-ee-ff-gg
ET-6x7-aa-bbT -dd-ee-ff-gg
ET-6x7-aa-bbTG -dd-ee-ff-gg
ET-6x7-aa-bb-ccSND -ee-ff-gg
ET-6x7-aa-bb-cc-ddAC -ff-gg
ET-6x7-aa-bb-cc-ddDC -ff-gg
ET-6x7-aa-bb-cc-dd-eeO30 -gg
ET-6x7-aa-bb-cc-dd-ee-ffAL
ET-6x7-aa-bb-cc-dd-ee-ffRM
NOTICE
Description
Type with
DVI1 KVM, with direct copper connection, Gigabit
(Ex e)
DVI1 KVM, with direct optical fibre connection
(Ex op is), multi-mode
DVI1 KVM, with direct optical fibre connection
(Ex op is), single mode
DVI2 ** KVM, with direct copper connection,
Gigabit (Ex e)
DVI3 KVM, with direct copper connection, Gigabit
(Ex e)
DVI3 KVM, with direct optical fibre connection
(Ex op is), multi-mode
DVI3 KVM, with direct optical fibre connection
(Ex op is), single mode
TFT display (standard)
Touch screen (membrane)
Touch screen glass
Audio amplifier (mono amplifier) 3.5 W
Power supply 100 - 240 VAC, 50 - 60 Hz
Voltage supply 24 VDC
Outdoor installation -30 °C [-22 °F] *
Aluminium front plate
Rear end module
* The O30 option is only available for AC devices !
* * The DVI2 KVM solution is only available together with the ET-667
HMI device !
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 27 of 92
Operating Instructions ET-xx7 Safety information
11 Safety information
CAUTION
The notes listed in section 11. must be heeded to avoid injury and damage to equipment !
11.1 General Safety Information
All relevant accident prevention regulations and the rules for electric installations have to be observed during installation, maintenance and operations. All persons involved in installation, commission, maintenance and repairs of this device and its accessories must be qualified accordingly and must have familiarised themselves with this manual and any associated documentation.
In case of non-compliance or contravention of the above explosion-protection is no longer guaranteed and all warranty claims shall be null and void.
National safety and accident prevention rules apply.
Use the device for its intended purpose only.
No changes to the device are permitted. The enclosure may only be opened by R. STAHL
HMI Systems GmbH.
ATTENTION
For reasons of explosion protection, there is, due to the design, a small gap between the touch surface and the cover. Therefore, the devices should not be used in high pollution environments !
Under conditions of high pollution the manufacturers understand areas in which solid particles, smaller than 100 μm, form sludge and incrustations and thus can clog the gap.
11.2 Cautionary note
ATTENTION
This is an EN 55022 Class A product.
In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
11.3 Installation safety information
The in each case valid national assembly and installation rules and the generally accepted technical rules must be observed. The device and its accessories must be connected and operated according to applicable standards, directives and installation guidelines. Only qualified personnel or personnel that has been instructed accordingly are allowed to install the device.
The HMI device has been certified as a fixed installed device. It must be fixed with a bracket or be secured in another way at a specified position.
The HMI device must be disconnected from the mains for a change of position. The EPL must be adhered to.
The HMI device's front should be protected by a canopy against permanent exposure to
UV light. This increases the front membrane's lifespan. The canopy MUST NOT be too close to the front plate and sufficient air circulation must be ensured.
Only appropriate tools must be used for the installation.
According to IEC 60950, a suitable, easily accessible circuit breaker must be installed outside of the xx7 (version AC) which can cut the power line.
The screws on the lid of the Ex e connection box must be fastened with a torque of 1 Nm.
Page 28 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Safety information Operating Instructions ET-xx7
The cable connections of the connection box must be in line with country-specific regulations and may have to be adapted accordingly. Potential changes to the ambient parameters such as temperature must be taken into account.
The cable entries in the connection box must have ingress protection IP66 or may have to be adapted to meet country-specific requirements. The pre-assembled cable entry threads are:
- 2x M16x1,5
- 1x M20x1,5
- 3x M25x1,5
The wall of the terminal box where the cable entries are mounted has a thickness of at least 4 mm.
The cable connections must be tightened fast according to regulations. Unused cable connections must be sealed with appropriate blind plugs. Only permanently laid cables may be connected to the pre-mounted ATEX cable connections.
The outer cable diameters must correspond to the cable connection specifications.
- Cable entry M16 for round cable, outside cable cross-section
4...8 mm (0.16"...0.31") or 5...10 mm (0.197"...0.39")
- Cable entry M20 for round cable, outside cable cross-section
6...12 mm (0.24"...0.47")
- Cable entry M25 for round cable, outside cable cross-section
14…18 mm (0.55"…0.71")
The HMI device must not be opened, maintained or repaired in hazardous atmospheres
(sole exception: the Ex e connection box).
Before opening the Ex e connection box, ensure that all Ex e and Ex i circuits are fully de-energised and isolated. You must also ensure that the power supply circuit is isolated.
The cable diameter must meet the terminal specifications. The Ex e connection box must be tightly sealed.
All Ex e and Ex i circuits must be completely de-energised before the HMI device is connected. After the Ex e and Ex i circuits have been de-energised, wait for at least seven minutes before opening the Ex e connection box. The Ex e connection box must not be opened if the HMI device is energised.
The earth / ground (equipotential bonding) connector at the back of the HMI's enclosure must be connected to the equipotential bonding conductor of the hazardous area. The earthing cable must have a minimum cross section of 4 mm² and be fitted properly. To prevent equalizing currents flowing to the earth / ground (equipotential bonding) system of the HMI device it is necessary to safely isolate any connected devices from earth or to integrate them into the earth / ground (equipotential bonding) system of the HMI device.
We recommend you use screened cables with the HMI device. Routing of the data cable may reduce performance. Cables for intrinsically safe wiring have to pass a test voltage of
AC 500 V / DC 750 V. Use the values 200 pF/m and 1 μH/m at unknown cable properties.
We recommend you use a PG fitting (e.g. UNI_Dicht_HF TM ) for the screen connection over a large surface of the data cable between the 6x7-KVM-DVI3 transmission unit and the HMI device. In this case, the data cable's scree must not be connected again inside the HMI device at the screen connection rail.
If display types ET-xx7-DVI1-MM or ET-xx7-DVI1-SM are used, terminal X16 remains unused.
To establish a secure earthed connection between HMI device and plant and to prevent inadvertent loosening of the cables, each cable with its screen must be connected to the corresponding earthing bracket located in the Ex e connection box close to the associated terminal.
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 29 of 92
Operating Instructions ET-xx7 Safety information
At the place of installation voltage must not exceed 250 V and short-circuit current must not exceed 1500 A.
A tick close to the X10 terminal indicates the voltage type (AC / DC). For the 24 VDC types the cable cross-sections depend on the cable length of the voltage supply cable, as follows:
Cable length in metres (ft) Cable cross-section in mm² (AWG) max. 55 m (180 ft) max. 90 m (295 ft) max. 150 m (492 ft) max. 225 m (738 ft) max. 375 m (1230 ft) max. 600 m (1968 ft)
1.5 mm² (AWG16)
2.5 mm² (AWG14)
4 mm² (AWG12)
6 mm² (AWG10)
10 mm² (AWG8)
16 mm² (AWG6)
If the cable's cross section is greater than the maximum possible for the terminals, the cable needs to be routed according to regulations via a smaller cable cross section before being inserted into the connection box (possibly using the Ex e terminal box).
When the interface of intrinsically safe devices / partial intrinsically safe devices was or is connected to not intrinsically safe interfaces, the license will become void and it must be operated as a not intrinsically safe device. If the device was operated on an intrinsically safe interface with a lower level of international protection (e.g. an Ex ia device on an
Ex ib interface), it must not be operated afterwards in applications for a higher level of international protection (e.g. Ex ia).
If the HMI device is being used in a dust atmosphere and must be replaced, the device or the enclosure in which it is mounted must be disconnected from the mains first and then, according to regulations, be left to cool down. Before opening the HMI device or its enclosure and whilst they are open, the environment must be kept dust-free so that no dust can intrude into the inside of the enclosure. When mounting new components please ensure that all seals are undamaged and fit tightly.
Before starting up the HMI device you must ensure that it has been installed according to regulations and that neither the device nor its cables are damaged.
ATTENTION
The audio Interface (X105) can handle high voltage up to 100 V. For installation and wiring the national standards must be observed and a properly insulation needed to prevent a hazard.
11.3.1 Only for HMI devices with DVI3
The USB interfaces of the ET-6x7-DVI3 devices are only certified for the connection of keyboards and pointer units from R. STAHL HMI Systems GmbH.
11.3.2 HMI installation in enclosures with degree of protection "e" or "t"
If the ET-xx7 HMI devices are mounted inside an enclosure with degree of protection Ex e or
Ex t, the mechanical impact protection and the IP of the enclosure (up to IP65) is retained even after the device has been installed. The internal separation requirements and the temperature conditions of the Ex e enclosure must adhere to the applicable directives. The distance between the terminals of the HMI devices and other, insulated, conductive parts (except earth) within the
Ex e enclosure must be at least 50 mm.
Page 30 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Safety information Operating Instructions ET-xx7
11.3.3 Conditions of safe use according to CEC / NEC / CSA
Application supporting devices connected to the intrinsically safe input / outputs of connection points X101, X105, X97, X13, X14, and X16 shall be installed in a nonhazardous location (see control drawing 11100024) or must be suitable protected by an explosionproof or Ex p enclosure.
Connection point X10 shall be connected to a Class 2 supply for the DC model.
All connections to the display unit shall be installed using a CSA certified or us ULc listed
Ex e cable gland suitable for the end installation and shall carry a minimum IP rating of
IP65.
Any non-metallic parts of the HMI device that can accumulate static electricity must be cleaned only with a damp cloth.
11.3.4 Tightening torque
11.3.4.1 Terminals
NOTICE
11.3.4.2 Cable glands
The stipulated tightening torques of the connection terminals must be observed and applied. Again, they must be checked and possibly adjusted before commissioning !
The tightening torques for the cable glands may vary depending on the cables and wires used. The users have to determine and apply the required torques themselves.
In the case of ex-factory systems, all components are installed correctly and in accordance with applicable standards. Since storage or temperature etc. can have an impact on the cables and cable glands, the pre-installed screw connections must be checked and possibly tightened before commissioning.
If they are too loose or too tight, the type of protection, sealing or strain relief might be negatively impacted.
Cable glands with cap nut and without strain relief clamp should only be used for permanently installed cables and electrical lines. Installation of the required strain relief is the responsibility of the system set-up engineer.
11.4 Industrial Security
Our products with Industrial Security functions support the secure operation of plants, systems and equipment. Protection against cyber threats requires an all-encompassing Industrial
Security concept. The key to a successful concept is integrated implementation, continuous maintenance and state-of-the-art technology. This is the responsibility of the plant operator.
The following are key issues for an effective Industrial Security concept:
Prevention of unauthorised access to plants, systems, equipment and networks
Systems, equipment and components should only be connected to the company intranet or the internet if and when required
Employ protective measures such as firewalls and network segmentation
Only use the latest software product versions
Carry out software updates as soon as new versions are available
Use standard user accounts for regular operation
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 31 of 92
Operating Instructions ET-xx7 Safety information
Use secure passwords
Appropriate safeguarding of administrator accounts
Application of security guidelines
Other measures to be taken as required
R. STAHL is constantly working on enhancing its products, thereby contributing to plant security and to minimizing the risk of cyber threats.
11.5 Safety information for operation
Operate the HMI device only if it is clean and undamaged. If the HMI device is in any way damaged, do not touch it to avoid injury. In the case of any damage that may compromise ingress protection (e.g. cracks, holes or broken components) the HMI device must be taken out of commission immediately. Before the device is recommissioned the damaged components must be replaced.
If you want to use the device in zone 20, 21 or 22 as EPL Da/Db/Dc, dust deposits of a thickness exceeding 5 mm must be removed and you have to ensure that no high-energy loading mechanisms at the operating surface of the unit (e.g. pneumatic particle transport) occur during operation. The HMI device may not be used in environments where propagating brush discharges may occur.
In general, and particularly when opening and closing enclosures, users must take care not to get injured by getting caught / trapped.
In case of non-compliance or contravention of the above explosion-protection is no longer guaranteed and all warranty claims shall be null and void.
11.6 Special conditions
Along the intrinsically safe circuits between the display unit and pointing device potential equalization must exist.
The pointing device shall not be used in areas where charging mechanism creating propagating brush discharges have to be regarded.
Page 32 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Assembly and disassembly Operating Instructions ET-xx7
12 Assembly and disassembly
12.1 General information
NOTICE
Assembly and disassembly are subject to general technical rules.
Additional, specific safety regulations apply to electronic and pneumatic installations.
12.2 Cut-out ET-xx7
Make a cut-out with the following dimensions:
Width Height
615 ± 0.5 435 ± 0.5
24.21" ± 0.002" 17.13" ± 0.002"
Depth of cutout
110
4.33"
12.3 Tightening torque
Material thickness up to 5 up to 0.02"
Unit of mesurement mm inch (")
NOTICE
The tightening torque of the nuts for the fixing bolts of the
ET-4x7/5x7/6x7 panel mount devices is 1.2 Nm (+- 0.2 Nm) !
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 33 of 92
Operating Instructions ET-xx7 Operation
13 Operation
13.1 General information
NOTICE
13.2 Connections
When operating the devices, particular care shall be taken that:
the HMI device has been properly installed according to instructions,
the HMI device is undamaged,
the terminal compartment is clean,
all screws are tightened fast,
before switching the HMI device on, its external equipotential bonding terminal is properly connected to the equipotential bonding system at its place of use,
the cover of the terminal compartment is completely closed.
Terminal Pin
X10
PWR
1
Definition / typical cable color
Power supply HMI device +24 VDC or 100 - 240 VAC
2 Power supply HMI device 0 VDC or 100 - 240 VAC
3 Earth connection
X11
KBi
X12
Mi
X13
1
2
3
4
1
2 D-
3 D+
4
1
2
3
4
+UB
D-
D+
GND
+UB
GND
+UB
D-
D+
GND
Red
White
Green
Black
Red
White
Green
Black
Red
White
Green
Black
Connection
Power supply of the HMI device.
Ex e
USB interface
Ex ia for
External keyboard
USB interface
Ex ia for
Mouse
USB Ex e
X14 1 +12 V
2 GND
Red
Black
12 VDC output
Ex e, max. 500 mA
X16 TX 2TX TX 2TX Ethernet copper
CAT7 / 1 TRD0+ TxD + 1 White / Orange White / Orange 1 connection *
CAT5
Data
2
3
TRD0-
TRD1+
TxD - 1
RxD + 1
Orange
White / Green
Orange 1
White / Green 1
Ex e either *
4
5
6
TRD1-
TRD2+
TRD2-
RxD - 1
TxD + 2
TxD - 2
Green
Blue / White
Blue
Green 1
White / Orange 2
Orange 2
TX or 2TX
7 TRD3+ RxD + 2 White / Brown White / Green 2
8 TRD3- RxD - 2 Brown Green 2
9 SHLD SHLD Screen Screen
(2TX not for
600 SERIES)
X18
FO 1
Data
Optical fibre connection type LC
Duplex connector
Ethernet optical fibre interface *
Ex op is
Page 34 of 92
Tx Rx
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
X105
AUD
X105
AUD
Operation
X24
USB1i
X25
USB2i
X97
SER
X101
CAM
1 +UB
2 D-
3 D+
4 GND
1 +UB
2 D-
3 D+
4 GND
1 TxD
2 RxD
3 RTS
4 CTS
5 GND
1 Signal FBAS
2 Screen (GND)
1 CH1 / line out left
2 CH2 / line out right
3 CH3 / line in left
4 CH4 / line in right
5 GND
1 LS1+
2 LS1-
3 LS2+
4 LS2-
5 GND
Red
Black
Red
Black
Black or
Red
Black
Red
Black
Black
Red
White
Green
Black
Red
White
Green
Black
Blue / White
Blue
White / Orange
Orange
Black
White
Black
Operating Instructions ET-xx7
USB interface
Ex ia
USB interface **
Ex ia
Serial
Ex e interface
RS-232
Video
Ex e interface
(optional) not for ET-x77-*-P2 devices
Audio
Ex e interface
(Line in only
600 SERIES)
Audio sound
Ex e interface
(optional) not for ET-x77-*-P2 devices
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 35 of 92
Operating Instructions ET-xx7
NOTICE
Operation
The following applies to all terminals:
0.2 - 2.5 mm² / AWG24 - AWG14 for flexible cable
0.2 - 4 mm² / AWG24 - AWG12 for rigid cable
Strip cable of 7 mm (0.28 in) insulation max. one cable per terminal
Recommended cable length for terminals X11, X12, X13, X14,
X24, X25: max. 3 m (10 ft)
* Please note that the Ethernet connection is either for an optical fibre connection (X18) or for a copper connection (X16), depending on the version ordered !
Up from HW-Rev. 01.03.02, all ET-4x7 and ET-5x7 devices with
SX and LX Ethernet interface are fitted additional with an
Ethernet TX interface !
The option 2TX is only possible at devices with Bay Trail (BT) and
AMD processor and NOT at 600 SERIES !
The device ET-x77-*-P2 has a second Ethernet TX (copper) interface in the TX version (1TX not available).
If display types ET-xx7-DVI1-MM or ET-xx7-DVI1-SM (optical fibre versions) are used, terminal X16 remains unused.
In the case of an optical fibre connection the following cable is recommended:
Multi-mode optical fibre cable:
50 µm core cross section and 125 µm external cross section
Single mode optical fibre cable:
9 µm core cross section and 125 µm external cross section
** The USBi2 connection (X25) is NOT available for devices with touch screen and may NOT be connected.
The unused wires of X16 at version 2TX must be isolated according to applicable regulations. This may be by means of double isolation and mechanical fixing by shrink sleeving or vulcanisation. The shrink sleeving or the vulcanisation must be suitable for at least 500 V and be within the temperature parameters of the device. The shrink sleeving / vulcanisation must NOT be light blue. When the data cables are shortened, this must also be kept in mind.
Page 36 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
General Information Operating Instructions ET-xx7
14 General Information
14.1 Touch driver
NOTICE
The UPDD touch driver is copyrighted licensed software supplied strictly for use with original R. STAHL HMI Systems GmbH touch systems and under no circumstances should this driver be downloaded or used on any other equipment !
14.2 ET-4x7 (Panel PC) and ET-5x7 (Thin Client)
14.2.1 Up to Windows 7 operating systems
14.2.1.1 Licensing issues
The HMI devices SERIES 400 and 500 which are pre-installed with a Windows operating system are equipped with a license sticker.
The license sticker is affixed on the back of the HMI device, next to the type plate.
Please note that according to the license issued for Windows the application of this system as an Office PC is not permitted.
DOCUMENTATION
Please also note the information on the licensing stipulations for Windows operating systems contained in the "TechNote Windows Operating Systems" file located on the CD / DVD / USB stick, which is part of the delivery.
14.2.1.2 Note on Windows Embedded operating systems
When using the Windows Embedded operating systems (XP or Windows Standard 2009 / 7) on the Panel PC devices SERIES 400, the C:\ system drive can be protected from unauthorised writing (EWF).
NOTICE This is NOT the case with other Windows operating systems !
ATTENTION
R. STAHL HMI Systems GmbH recommends you leave the write protection filter on at all times !
DOCUMENTATION
For further information regarding this Write Protection
(EWF), please refer to the OpenHMI_help_en.chm help file in the "STAHL" folder on the device or on the CD / DVD /
USB stick that is included in the delivery.
14.2.2 Windows® 10 IoT Enterprise 2019 LTSC operating system
The operating system is based on Windows 10 for PC platforms with 64 bit x86 processors. For the LTSC (Long Term Servicing Channel) versions, Microsoft guarantees 10 years of security updates and new builds with feature updates only every 2-3 years, with these being optional.
The LTSC versions are ideal for industrial applications and feature additional security components such as write filters (UWF) and HORM (start of a system snapshot from the RAM plus write protection).
From 2016 LTSB onwards, Microsoft has tied its licensing model to the processor performance:
ENTRY for AMD® GX and ATOM™
VALUE for Intel® Core i5™
HIGH for Intel® Core i7™
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 37 of 92
Operating Instructions ET-xx7 General Information
The Panel PC SERIES 400 HMI devices with Windows 10 IoT Enterprise 2019 LTSC operating systems have the license provided as part of the image, with the corresponding label affixed to the back of the device. When delivered, the devices have already been registered and activated.
The EOL (End of Life) date for Windows 10 IoT Enterprise 2019 LTSC for support and updates has been set by Microsoft to 09.01.2029.
14.2.2.1 Recovery
NOTICE
If a Panel PC is reset to the factory state (recovered) it will remain registered but will have to be reactivated !
This requires an active internet connection to a Microsoft server !
14.2.2.2 Company-specific Windows installations
NOTICE
The Windows 10 IoT license key is tied to STAHL images !
The installation of own Windows 10 IoT operating systems requires a separate license key !
All necessary drivers are provided by R.STAHL HMI Systems GmbH.
Please contact our Support department.
14.2.3 Initial start-up ET-4x7 (Panel PC)
When the device is started for the first time, the Windows installation assistant starts where users have to select certain settings.
Please follow the instructions of the installation assistant.
14.2.4 Recovery Stick
NOTICE
To restore your Panel PC device to its original state you will need a
Recovery Stick, which is part of the delivery. This recovery stick
(USB-drive) contains the factory image, with which the system can be restored to delivery status within a very short time.
Please note that you can restore the HMI devices to their original state only with the aid of the Recovery Stick
As an option, the recovery stick can also contain a backup software, with which you can back up your own device configuration.
The optionally available intrinsically safe recovery stick (USB i -drive) can not be used at the interfaces of the ET-xx7 devices !
14.2.5 Back-up
NOTICE
Please note that it is the sole responsibility of the operator to generate a back-up of the HMI devices and their overall function.
We strongly recommend such a back-up to be stored on an external storage medium or on the company network.
Page 38 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
General Information Operating Instructions ET-xx7
14.2.6 Switching off / closing down
NOTICE
The Microsoft Windows operating system stores key data in the main memory, regardless of the application, and has to store this data on the hard disk before the HMI device is switched off.
ATTENTION
It is therefore important for the safe and correct operation that the
HMI device is closed down properly (see illustration below) and NOT simply switched off.
Otherwise the existing image of the device may be damaged, rendering the HMI device non-functioning.
14.2.7 Data loss
NOTICE
In the case of applications that require constant writing into memory,
R. STAHL HMI systems recommends you use external storage media (USB sticks, network servers) for these write processes.
ATTENTION
Try and avoid cyclical writes (log files, databases, etc.) to the SSD !
The endurance of an SSD depends on the number of write cycles
(TBW / terabytes written).
Writing to the SSD with a simultaneous drop in voltage is most likely going to result in data loss !
14.3 Teaming function
NOTICE For SERIES 500 only
Processor
ATOM 3845
AMD
2TX
Yes
Yes
Teaming function
Interface
SX and TX
No
No
LX and TX
No
No
Providing redundancy due to automatic switch to a different network adapter.
Using the Ethernet adapters in the team as standby adapters, realising redundancy, making the system more fail-safe.
Bundling the speed of the Ethernet adapters in order to increase performance.
DOCUMENTATION
For a description of the function and its settings refer to the Remote HMI V6 software manual (industrial-grade
Thin Client firmware).
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 39 of 92
Operating Instructions ET-xx7 Maintenance, overhaul
15 Maintenance, overhaul
Because the transmission of the devices remains reliable and stable over long periods of time, regular adjustments are not required.
Keep the units clean so that the enclosure locks and screws remain accessible. Maintenance may be required for the enclosure seal.
System maintenance should focus on the following: a. Seal wear b. Display damage c. All screws are tightened fast d. All cables and lines are properly connected and undamaged
CAUTION
If the device in its factory state is damaged or altered in any way, decommission it immediately and contact the R. STAHL HMI
Systems GmbH !
If small glass beads (filling material) escape the device, immediately decommission the device !
15.1 Damaged sealing
NOTICE
If a defective seal is found on a device that has been returned to the manufacturer, an agreement is made with the customer as to whether it should be repaired (replaced).
If this exchange is not necessary, the option "No hazloc approved panel mount" is marked on the device by the manufacturer.
The device is only approved for installation inside an Ex e or Ex tb enclosure if no "No hazloc approved panel mount" option is indicated on the device !
16 Troubleshooting
Devices operated in hazardous areas must not be modified. Repairs may only be carried out by qualified, authorized staff specially trained for this purpose.
NOTICE
Repairs may only be carried out by specially trained staff who are familiar with all basic conditions of the applicable user regulations and – if requested – have been authorized by the manufacturer.
16.1 Repairs / hazardous substances
An error description must be enclosed with any units returned to R. STAHL HMI Systems GmbH for repairs.
Remove all material residues. Please pay particular attention to the seal grooves and slits where material residues may be lodged. We have to ask you not to return a unit if you are unable to completely remove any hazardous substances. We shall bill you for any costs arising from insufficiently cleaned units, such as disposal or damage to persons (chemical burns, etc.).
Page 40 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Disposal / Restricted substances Operating Instructions ET-xx7
17 Disposal / Restricted substances
Disposal of old electric and electronic devices, packaging and used parts is subject to regulations valid in whichever country the device has been installed.
For countries under the jurisdiction of the EU the corresponding WEEE directive applies.
The devices are classified according to the table below:
Directive
Valid
Category
WEEE II directive 2012/19/EU from 2018-08-15
SG2 screens, monitors, devices with monitors >100 cm²
R. STAHL HMI Systems GmbH meets the requirements of directive 2012/19/EU (WEEE) and is registered under the number DE 15180083.
We shall take back our devices according to our General Terms and Conditions.
17.1 Declaration of substances and restricted substances
The present declaration is based on the procedure described in the international standard and directives as listed in the table below:
IEC 62474 : 2018 (DIN EN IEC 62474 : 2019-09)
(EG) Nr. 1907/2006 (REACH)
Directive 2011/65/EU (RoHS)
Resolution MEPC.269(68) "International Maritime Organization" (IMO); particularly
"2015 Guidelines for the Development of the Inventory of the Hazardous Materials" (IHM)
17.1.1 Declarable substance groups
ECHA Legal Entity UUID of the R. STAHL HMI Systems GmbH:
ECHA-a4dd94d5-bcd2-405d-8fdd-010a535d7e87
SCIP number: c335aec6-42c1-4204-8edf-b5b8d26ee81e
Component Designation
Mass
(g)
Declarable Substance
Groups and Substances
(IEC 62474 database)
CAS Nr. Mass %
Exemption
(acc. to directive)
BR2032
Lithium coin cell
2.6
Ethylenglycoldimethylether
(1.2-Dimethoxyethan /
EGDME)
BR2330
Lithium coin cell
3.2
Ethylene glycol dimethyl ether
(1.2-Dimethoxyethan /
EGDME)
17.1.2 RoHS directive 2011/65/EC
110-71-4
110-71-4
The devices meet the requirements of RoHS Directive 2011/65/EU.
3.6104
3.8100
-
-
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 41 of 92
Operating Instructions ET-xx7 Defective pixels
17.1.3 IMO Resolution MEPC.269(68)
The devices meet the requirements of the MEPC.269(68) Resolution of the "International
Maritime Organization" (IMO), in particular the "2015 Guidelines for the Development of the
Inventory of the Hazardous Materials" (IHM).
18 Defective pixels
As a result of the manufacturing process (production tolerances and errors) for the displays they may be delivered with defective pixels. Provided they are within the range of the specification below these potential defective pixels are not a display or HMI error or defect.
18.1 Terminology
Defective pixels Pixels or sub-pixels that do not perform as expected and are either always on or always off
Pixel Image point on the display consisting of 3 sub-pixels in the basic colours red, green and blue
R G B
Dot
Bright
Sub-pixel in the basic colour red, green or blue
R or G or B
Sub-pixel (dot) to which light is passing through, creating a bright dot that is on
Dark Sub-pixel (dot) to which no light is passing through, creating a dark dot that is off adjacent dots dots positioned next to one another, horizontally, vertically or diagonally, bright or dark
(e.g. the following pattern and sub-pixels)
R G B R G B R G B R G B
R G B R G B R G B R G B
R G B R G B R G B R G B
Page 42 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Defective pixels Operating Instructions ET-xx7
Distance between
Dots
Definition of distance between two defective dots horizontal, vertical or diagonal, bright or dark
(e.g. the following pattern and sub-pixels)
R G B R G B R G B R G B
R G B R G B R G B R G B
R G B R G B R G B R G B
18.2 Display specification ET-x77
Type of defect / description
Linear defect (horizontal, vertical, diagonal)
Defective pixels bright dots dark dots total number of dots adjacent dots
2 bright dots more than 3 bright dots
2 dark dots more than 3 dark dots
Distance between the dots between 2 bright dots between 2 dark dots
between 1 bright and 1 dark dot
ND filter for mura effects, bright and dark dots max. number of permitted defects
24" display not permitted
≤ 2
≤ 5
≤ 5
≤ 1 pair not permitted
≤ 2 pairs not permitted
≥ 15 mm
≥ 15 mm
≥ 15 mm view with 8% filter
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 43 of 92
Operating Instructions ET-xx7
19 Control Drawing CEC / NEC / CSA
Control Drawing CEC / NEC / CSA
Page 44 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Control Drawing CEC / NEC / CSA Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 45 of 92
Operating Instructions ET-xx7 Mounting inside enclosure with ET-xx7 mounting-set
20 Mounting inside enclosure with ET-xx7 mounting-set
Page 46 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Mounting inside enclosure with ET-xx7 mounting-set Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 47 of 92
Operating Instructions ET-xx7
21 Declarations of conformity
21.1 EC
Declarations of conformity
Page 48 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 49 of 92
Operating Instructions ET-xx7
21.2 RCM
Declarations of conformity
Page 50 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 51 of 92
Operating Instructions ET-xx7
21.3 EAC
Declarations of conformity
Page 52 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 53 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 54 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 55 of 92
Operating Instructions ET-xx7
21.4 CCC
21.4.1 English version
Declarations of conformity
Page 56 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 57 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 58 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 59 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 60 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 61 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 62 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 63 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 64 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 65 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 66 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 67 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 68 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 69 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 70 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 71 of 92
Operating Instructions ET-xx7
21.4.2 Chinese version
Declarations of conformity
Page 72 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 73 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 74 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 75 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 76 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 77 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 78 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 79 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 80 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 81 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 82 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 83 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 84 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 85 of 92
Operating Instructions ET-xx7 Declarations of conformity
Page 86 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
Declarations of conformity Operating Instructions ET-xx7
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021 Page 87 of 92
Operating Instructions ET-xx7 Release notes
22 Release notes
The chapter entitled "Release Notes" contains all the changes made in every version of the operating instructions.
Version 01.03.21
Changing HW rev. at cover
Addition of table "Overview hardware revision"
Addition of "FSB notification"
Changing text (with and without lettering) according to documentation note in "Specific markings"
Addition of "cable glands" in "Technical Data"
Changing values according to "cable gland M16" in "Installation safety information"
Changing text in notice "No hazloc approved panel mount"
Addition of safety information "protection by a canopy" in "Installation safety information"
Adaption of data according to "optical fiber" in "Technical Data"
Moving information on "Interface copper" from chapter 4 "Technical Data" to subsection
4.1 "ET-4x7" and 4.2 "ET-5x7"
Adaptation of data for "Interface copper" in the subsections
Changing of P2 into AMD at "Video, Audio and O30 Option" in "Technical Data"
Addition of "USB standard 2.0" and "Note USB interfaces" in "Technical Data"
Addition of "Class I, Division 2 and according information" at "Marking" at NEC and CEC
Addition of CCC and CNEX certification
Formal changes
Version 01.03.22
Removal of previous release notes
Changing values "cable glands" in "Technical Data"
Changing values according to "cable gland M16" in "Installation safety information"
Page 88 of 92
R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_03_22.docx / 30.09.2021
R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Köln
T: (Sales Support)
(Technical Support)
F:
E: (Sales Support)
(Technical Support) r-stahl.com exicom.de
+49 221 768 06 - 1000
+49 221 768 06 - 5000
+49 221 768 06 - 4100 [email protected]
Advertisement
Key Features
- Designed for use in hazardous areas
- Available in a variety of configurations
- Meet the highest safety standards
- Backed by Stahl's commitment to quality and reliability
- Rugged construction
- Advanced features