Stahl ET-/MT-xx7 Operating instructions
Stahl ET-/MT-xx7 is a state-of-the-art device platform MANTA (SERIES 400 / 500 / 600) that has been developed specially for process automation and for GMP and cleanroom applications. Suitable for hazardous areas zone 1, 21, 2 and 22 (depending on type), these devices are ideal for a great number of applications. It features a touch screen with multi-touch functions, Ethernet interface X16 for TX or 2TX with SERIES 400 / 500 and TX with SERIES 600. Furthermore, the device has an Ethernet optical fibre interface and can be mounted on a stand, ceiling, elbow or wall.
Advertisement
Advertisement
Installation Manual
SERIES 400 Panel PC
SERIES 500
Thin
Clients
SERIES 600 KVM Systems
Device platform MANTA
ET-xx7 / MT-xx7
HW-Rev. ET-4x7-*-BT:
HW-Rev. ET-5x7-*-BT:
HW-Rev. ET-5x7-*-P2:
HW-Rev. ET-6x7:
HW-Rev. MT-4x7-*-BT:
HW-Rev. MT-5x7-*-BT:
HW-Rev. MT-5x7-*-P2:
HW-Rev. MT-6x7:
Installation Manual version:
Issue date:
01.03.03
01.03.03
01.03.04
01.03.00
01.01.03
01.01.03
01.01.04
01.01.00
01.00.02
06.05.2019
Installation Manual ET-/MT-xx7 Publisher
Publisher
Publisher and copyright holder:
R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Cologne
Phone: (switchboard)
(hotline)
Fax:
E-mail: (switchboard)
(hotline)
+49 (0) 221 76 806 - 1000 [email protected]
- 5000
- 4100 [email protected]
All rights reserved.
This document may not be reproduced in whole or in part except with the written consent of the publisher.
This document may be subject to change (dates, dimensions, weight, constructions, drawings, images).
Any warranty claims are limited to the right to demand amendments. Liability for any damage that might result from the contents of these instructions or all other documentation is limited to clear cases of premeditation.
We reserve the right to change our products and their specifications at any time, provided it is in the interest of technical progress. The information in the current manual (online or on CD / DVD /
USB stick) or in the operating instructions included in the delivery applies.
Trademark
The terms and names used in this document are registered trademarks and / or products of the companies in question.
Copyright © 2019 by R. STAHL HMI Systems GmbH. Subject to alterations.
Page 2 of 24
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7
Table of contents
Description
Versions mounted on stand or elbow
Connection of the X10 power supply
TX or 2TX with SERIES 400 / 500
Ethernet optical fibre interface
Table of contents
Page
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019 Page 3 of 24
Installation Manual ET-/MT-xx7 Intended use and location
1 Intended use and location
The ET-/MT-xx7 devices, device platform MANTA (SERIES 400 / 500 / 600) have been developed specially for process automation and for GMP and cleanroom applications. Suitable for hazardous areas zone 1, 21, 2 and 22 (depending on type), these devices are ideal for a great number of applications.
2 Warning
2.1 Touch operation
Incorrect / phantom operation:
Incorrect operation of the touch screen may result in accidental functions and errors. The device will then be unable to execute functions, may execute them incorrectly or in a way not intended.
- Do not realise safety-relevant functions via the touch screen
- Avoid accidental multi-touches
- Do not touch the touch screen across a large area
- Use a touch pen only for the capacitive touch screen
- Before operating the device, thoroughly acquaint yourself with the multi-touch functions of the operating system and the application
- Switch off the device for cleaning and maintenance
Conductive liquids on the touch screen can result in incorrect or phantom operations. This applies in particular to salt water.
- Avoid contamination of the touch screen surface with salt water
Protect the device against rain, snow and splashes, since excessive amounts of standing or running water will disrupt operation and may cause erratic cursor movement.
This protection can be achieved by using a canopy or some other protective roof-type construction. Offshore, strong winds, saltwater and rain will have to also be taken into consideration.
Touch screen damage:
Only touch the touch screen with your finger or a suitable pen.
- Do not touch the screen with pointed or sharp instruments as this may damage the touch screen, substantially reduce its service life or result in total black-out
Foil membrane blistering / air-pockets:
Extreme ambient conditions (high humidity, temperature) may, in rare cases, result in blistering or air-pockets underneath the foil touch screen. This does not impede functionality and is a purely optical phenomenon.
Page 4 of 24
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7
3 Enclosure types
HSG-xx7-VxA-FR with front door as standard
Enclosure types
HSG-xx7-VxA-CFR with front door for cleanroom
HSG-xx7-VxA-BD with rear door (Backdoor)
HSG-xx7-VxA-FR / HSG-xx7-VxA-CFR for wall mounting
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019 Page 5 of 24
Installation Manual ET-/MT-xx7 Versions mounted on stand or elbow
4 Versions mounted on stand or elbow
mounted upright on elbow mounted hanging from elbow
MPFL stand
Page 6 of 24
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7 Mounting
5 Mounting
In regards of different applications and ambient conditions we recommend following installation types:
5.1 Mounting options
Mounted on stand Ceiling mounting
Elbow upright mounting Mounted hanging from elbow
Wall mounting
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019 Page 7 of 24
Installation Manual ET-/MT-xx7 Mounting
5.2 Recommended mounting type
The following recommended mounting types are the result of trying out many different types over the years. Please follow these recommendations to ensure the optimum mounting type for your device.
Before deciding on how to mount the device you need to check the vibration and shock conditions.
We cannot accept any responsibility if you select an unsuitable mounting type that results in damage or failure of the device.
Conditions present at the point of installation
Mounting / installation type Recommendation
Mounting on MPFL stand, with / without external keyboard
No restriction
No vibration and no shocks
Ceiling mounting with
MPFL stand with / without external keyboard
Mounted on elbow standing with / without external keyboard
Mounted on elbow hanging with / without external keyboard
Wall mounting with / without external keyboard
No restriction
No restriction
No restriction
No restriction
Mounting on stand with / without external keyboard
Not recommended
Vibration sinusoidal acc. to IEC 60068-2-6
5 … 13.2 Hz: ±1 mm
13.2 … 100 Hz: ±0.7 g
Change cycle 1 oct/min
X, Y, Z axes
Dwell Test:
71.7 to 79.2 Hz: ±0.7 g
120 min.
Change cycle 1 oct/min
X axis
30 Hz: ±0.7 g
90 min.
Change cycle 1 oct/min
Y, Z axes
Page 8 of 24
Ceiling mounting with
MPFL stand, with / without external keyboard
Mounted on elbow standing with / without external keyboard
Mounted on elbow hanging, with / without external keyboard
Wall mounting with / without external keyboard
Not recommended
Not recommended
Not recommended
No restriction
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7 Tools
5.3 Assembly notes
The tightening torques for the cable glands depend on the cables and wires used. This means the user has to determine the required torques.
The stand / wall bracket must be mounted with at least 4 fastening points. The type of wall fixing used must be suitable for the wall material.
6 Tools
1x side cutter
1x wire stripping knife
1x wire stripper
1x spanner AF 10
1x spanner AF 13
1x spanner AF 14
1x spanner AF 24
1x spanner AF 30
1x Phillips screwdriver size 1
1x Phillips screwdriver size 2
1x flat-bladed screwdriver 2.5 mm
1x Allen key 5 mm
NOTE
Mounting the stand or wall-mounting will require additional tools not mentioned here.
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019 Page 9 of 24
Installation Manual ET-/MT-xx7 Mechanical Installation
7 Mechanical Installation
CAUTION
7.1 Dimensions
Dimensions in mm.
Mount the devices all the time with 2 persons together !
HSG-xx7-VxA-FR
A
740
B
568
C
190
D
720
E
304
F
400
G
78
HSG-xx7-VxA-CFR
H
34°
I
270
A
720
Page 10 of 24
B
627
C
190
D
720
E
304
F
406
G
78
H
34°
I
270
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7
HSG-xx7-VxA-BD
Mechanical Installation
A
740
B
568
C
195
D
720
E
304
F
442
HSG-xx7-VxA-*-W
G
78
H
34°
I
270
X
*a
NOTICE
Mounting tongues for wall mounting
Alternative mounting position of the mounting tongues
Enclosure types FR and CFR are used for wall mounting. The dimensions of these enclosures are listed in the above tables.
Choose suitable mounting screws, rawlplugs and bolts depending on the actual local requirements and possibilities.
Dimensions mounting tongue
A
30
B
55
C
35
D
10,5
E
10,5
F
18
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019 Page 11 of 24
Installation Manual ET-/MT-xx7
7.2 Mounted on stand
7.2.1 View
7.2.2 MPFL Stand
Mechanical Installation
All dimensions in mm.
A B C D
Stand
E
1216 265 200 135 20
Gl1
Cable glands
Gl2 Gl3
M25 x 1.5 M25 x 1.5 M20 x 1.5
F
101
G H
Ø 60.3 Ø 88.9
Page 12 of 24
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Mechanical Installation
7.2.3
1
Mounting – Step by step
NOTE
Choose suitable mounting screws, rawlplugs and bolts depending on the actual local requirements and possibilities.
2
8x Ø16 see dimensions "stand"
Earth of the stand
(see 8.1 Connection power supply)
Page 13 of 24
Installation Manual ET-/MT-xx7 Mechanical Installation
3
A mounting holes, hanging mounting
B mounting holes, standing mounting
3 Operator interface enclosure
Coupling (pre-mounted)
D Mounting holes in the enclosure of the operator interface
Page 14 of 24
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7
4
5
C
E
F
M6 allen screw
Mounting coupling
Stand / wall bracket or
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Mechanical Installation
Page 15 of 24
Installation Manual ET-/MT-xx7
6
7 tighten all 4 screws with a torque of 10 Nm
Mechanical Installation
Page 16 of 24
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7 Mechanical Installation
8
*1
Connection bolt for equipotential bonding. Already wired to the multiple connection (*2) in operator stations (OS).
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019 Page 17 of 24
Installation Manual ET-/MT-xx7
8 Electrical Installation
8.1 Connection of the X10 power supply
9
Electrical Installation
Label AC/DC version
Version Pin Signal
DC
1
2
Power supply +24 VDC
Power supply 0 VDC
3 Equipotential bonding / enclosure
AC
1 Phase conductor (L) 100 - 240 VAC
2 Neutral conductor (N) 100 - 240 VAC
3 Protective conductor / enclosure
WARNING
Connect only AC devices (look at device label) to 100 - 240 VAC mains !
8.2 Earthing of stand
10
1 = Stand mounting plate
2 = Washer 2x
3 = Toothed washer
4 = Hexagon screw M6x16
5 = Split washer
6 = Cable lug with eyelet
Page 18 of 24
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7 Electrical Installation
8.3 Ethernet interface X16
8.3.1
11
TX or 2TX with SERIES 400 / 500
Pin Signal Colour
1 TRD0+ White / Orange
2 TRD0- Orange
3 TRD1+ White / Green
4 TRD1- Green
5 TRD2+ White / Orange
6 TRD2- Orange
7 TRD3+ White / Green
8 TDR3- Green
9 SHLD Screen
Note twist
Connection
100Base-TX interface
2nd 100Base-TX interface
(only for option 2TX)
Connect screen separately to the screen connection rail
(see diagram)
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019 Page 19 of 24
Installation Manual ET-/MT-xx7
8.3.2
12
TX with SERIES 600
Electrical Installation
Wrong
Pin Signal Colour
1 TRD0+ White / Orange
2 TRD0- Orange
3 TRD1+ White / Green
4 TRD1- Green
5 TRD2+ White / Blue
6 TRD2- Blue
7 TRD3+ White / Brown
8 TDR3- Brown
9 SHLD Screen
8.3.2.1 Cable adaptation
Right
Note twist
Connection
Ethernet interface
Connect screen to the screen connection rail (see diagram)
Page 20 of 24
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Installation Manual ET-/MT-xx7
8.4 Ethernet optical fibre interface
13
Rx Tx
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
Electrical Installation
Page 21 of 24
Installation Manual ET-/MT-xx7 Release notes
9 Release notes
The chapter entitled "Release Notes" contains all the changes made in every version of the
Instructions.
Version 01.00.00
First edition
Version 01.00.01
Correction of version number in section "Release Notes"
Changing HW-Rev. at xT-4x7-*-BT and xT-5x7-*-BT at cover
Changing picture at cover
Correction data and content according to enclosure for wall mounting
Text-, layout- and formal corrections
Version 01.00.02
Changing HW-Rev. at xT-4x7-*-BT and xT-5x7-*-BT at cover
Addition of HW-Rev. for xT-5x7-*-P2 devices at cover
Correction pin colours 4 - 8 for "TX with SERIES 600"
Formal changes
Page 22 of 24
R. STAHL HMI Systems GmbH / IM_ET_MT-xx7_en_V_01_00_02.docx / 06.05.2019
R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Köln
T:
F:
E: r-stahl.com stahl-hmi.de
(switchboard) +49 221 76 806 - 1000
(Hotline) +49 221 76 806 - 5000
+49 221 76 806 - 4100
(switchboard) [email protected]
(hotline) [email protected]
Advertisement