Siko GP04/1 Geared potentiometer Data Sheet
Advertisement
Advertisement
Geared potentiometer GP04/1
With solid or blind hole shaft
Profile
■
■
■
■
■
■
Extremely resistant to external influences
Solid or blind-hole hollow shaft, max. Ø 20 mm
Adaptation to various measurement distances owing to a wide range of gear ratios
Integrated slip clutch to protect the potentiometer
Potentiometer, power or voltage output
IP65 protection category e sense of rotation
10° i
6.6
.5
19
87.5
100
15
4 max. allowable shaft load radial 1000N axial 1700N
15
V/16
119
PG9
17
55
20
28
4 max. 30 feather key groove
DIN 6885/1
H/16
Mechanical data
Feature
Shaft
Housing
Gear ratio
Speed
Shaft load rating
Potentiometer service life
080/08 05.03.2008
Technical data aluminum black-finished steel aluminum
0.2 … 256
≤500 rpm
≤1000 N
≤1700 N
1 x 10
6
revolution(s)
Additional information
IP52
IP65 depending on the transmission radial axial
2 RotoLine | 2.3 geared potentiometer
Ar tikel-Nr.
203562 www.siko-global.com
1
Geared potentiometer GP04/1
With solid or blind hole shaft
Electrical data
■
Encoder potentiometer type 01,1 helix
Feature
Power rating
Resistance
Resistance tolerance
Standard terminal resistance
Linearity tolerance
Design
Technical data
1 W at 70 °C
5, 10 kΩ
±10 %
0.5 %
±1 % hybride
■
Encoder potentiometer type 02,10 helices
Feature
Power rating
Resistance
Resistance tolerance
Standard terminal resistance
Linearity tolerance
Design
Technical data
2 W at 70 °C
1, 5, 10 kΩ
±5 %
0.5 %
±0.25 % wire
■
Encoder potentiometer type 03, 10 helices
Feature
Power rating
Resistance
Resistance tolerance
Standard terminal resistance
Linearity tolerance
Design
Technical data
2 W at 70 °C
1, 5 W, 10 kΩ
±5 %
0.5 %
±0.25 % hybride
■
Transducer, power output
Feature
Operating voltage
Output current
Technical data
24 V DC ±20 %
4 … 20 mA
■
Transducer, voltage output
Feature
Operating voltage
Output voltage
Technical data
24 V DC ±20 %
0 … 10 V
System data
Feature
Measuring range
Technical data
340° ±5° (mechanical full-length)
3600° +10°
Ambient conditions
Feature
Ambient temperature
Relative humidity
EMC
Protection category
Technical data
-20 … 80 °C
EN 61000-6-2
EN 61000-6-4
IP52, IP65
Additional information
≤30 V
Additional information
≤30 V
Additional information
≤30 V
Additional information at ≤500 Ω load
Additional information
Additional information potentiometer type 01 potentiometer types 02, 03
Additional information condensation inadmissible interference resistance / immission emitted interference / emission
EN 60529
2 RotoLine | 2.3 geared potentiometer www.siko-global.com
2
Geared potentiometer GP04/1
With solid or blind hole shaft
Pin assignment
■
Without transducer
Signal
Po
Pe
S
■
MWI transducer
Signal
I+
Inc
■
MWU transducer
Signal
+24 V DC
GND
Uout
Terminal
1
2
3
Terminal
1
2
3
2
3
Terminal
1 potentiometric outputs P01, P05, P10
Pe
... kΩ
S
Po transducer MWI
10 kΩ transducer MWU
10 kΩ
I+
I-
R/I transformer
R/U transformer
+UB
Uout
GND
3
2 RotoLine | 2.3 geared potentiometer www.siko-global.com
Geared potentiometer GP04/1
With solid or blind hole shaft
Order
■
Gear ratio calculation
Formula: i1 = n x 360°
α n = number of revolutions on the driving shaft
α = potentiometer angle of rotation
340° with 1-coil potentiometer
3600° with 10-coil potentiometer i1 = order feature for gear ratio
If the calculated ratio”i1” is the same as a value in the ordering table for the
“ratio” feature, but this is not availab- le, select the next highest ratio.
■
Ordering table
Feature
Gear ratio
Drive shaft
Potentiometer type
Analog output
Sense of rotation
Protection category
■
Order key
GP04/1 -
A
-
B
i e
52
65
Ordering data
...
A
Specification
0.1, 0.166, 0.25, 0.333, 0.5, 1, 2, 3, 4, 5, 6, 10,
12, 15, 20, 24, 30, 40, 55 others on request
Additional information
01
02
03
H/20
H/16
V/20
V/16
MWI
MWU
P01
P05
P10
B
C
D hollow shaft ø20 mm hollow shaft ø16 mm solid shaft ø20 mm solid shaft ø16 mm
1 helix, hybrid
10 helices, wire
10 helices, hybrid transducer 4 … 20 mA transducer 0 … 10 V potentiometer 1 kΩ potentiometer 5 kΩ potentiometer 10 kΩ only for P05 or P10 analog output
E no information required counter-clockwise ascending values clockwise ascending values
F IP52
IP65 only for P01, P05, or P10 analog output only for MWI or MWU analog output only for MWI or MWU analog output
C
-
D
-
E
-
F
4
Scope of delivery: GP04/1, Mounting instructions
Accessories:
Electronic display MA50
2 RotoLine | 2.3 geared potentiometer www.siko-global.com
www.siko-global.com

Public link updated