Advertisement
Advertisement
Wire-actuated encoder SG5
Miniature wire-actuated encoder with 600 mm measurement length
Profile
■
■
■
■
■
■
Very small design
Universally applicable thanks to standardized interfaces
Easy mounting
Measurement lengths up to max. 600 mm
Potentiometer, voltage or power output
Housing made of reinforced plastic measurement
path
4.3
19
2x M3 max. screw-in depth 6mm cable output
16 28.6
Mechanical data
Feature
Housing
Wire design
Extension force
Absolute accuracy
Cable length
Weight
Technical data reinforced plastic
ø0.36 mm
≥3 N
±0.35 % (potentiometer)
≤15 m
≤30 m
≤20 m
~0.06 kg
Electrical data
■
Encoder potentiometer
Feature
Power rating
Resistance
Resistance tolerance
Linearity tolerance
31.07.2008
Technical data
2 W at 70 °C
10 kΩ
±5 %
±0.25 %
40.7
Additional information steel wire (stainless), plastic coated relating to measuring length (mm)
P10 encoder type
MWI encoder type
MWU encoder type
Additional information
3 LinearLine | 3.1 Wire-actuated Encoder
Ar tikel-Nr .
200647 www.siko-global.com
1
Wire-actuated encoder SG5
Miniature wire-actuated encoder with 600 mm measurement length
■
Transducer, power output
Feature
Operating voltage
Output current
Technical data
24 V DC ±20 %
4 … 20 mA
■
Transducer, voltage output
Feature
Operating voltage
Output voltage
Load
Technical data
15 … 28 V DC
0 … 10 V DC
≤10 mA
*Measurement transducers permit optimum adjustment of the output current and output voltage to the measuring range. The measurement transducer is pre-set at the works so that an output signal of 4 … 20 mA (MWI) or 0 … 10 V DC (MWU) is available.
Additional information at ≤500 Ω load
Additional information at 3 mA, no load
I
Load
≤10 mA
System data
Feature
Repeat accuracy
Travel speed
Technical data
±0.15 mm
≤800 mm/s
Additional information
Ambient conditions
Feature
Ambient temperature
Relative humidity
Protection category
Technical data
-10 … 80 °C
IP50 (encoder part)
Additional information condensation inadmissible
EN 600529; with cable connected in the factory
2
3 LinearLine | 3.1 Wire-actuated Encoder www.siko-global.com
Wire-actuated encoder SG5
Miniature wire-actuated encoder with 600 mm measurement length
Pin assignment
■
Potentiometric outputs P10
Signal
Po
Pe
S
E1 (terminal) brown white green
■
MWI transducer
Signal
I+
I-
Cable color brown white
■
MWU transducer
Signal
+24 V DC
GND
U out
Cable color brown white green potentiometric outputs P01, P05, P10
Pe
... kΩ
S
Po transducer MWI
10 kΩ
I+
I-
R/I transformer transducer MWU
10 kΩ
+UB
Uout
GND
R/U transformer
Hint for mounting
When securing the wire it must be ensured that the wire is straight and vertical in relation to the wire outlet.
Recommendation: Only select the starting position after an unwound length of approx. 5 mm. This prevents the wire hitting the end stop when it is rewound. initial position final position symbolic depiction
~5 mm measuring range
≤ extension length
3
3 LinearLine | 3.1 Wire-actuated Encoder www.siko-global.com
Wire-actuated encoder SG5
Miniature wire-actuated encoder with 600 mm measurement length
Order
■
Ordering table
Feature
Measuring range
Encoder type
Cable length
■
Order key
SG5 -
A
-
B
-
C
Ordering data
300M
600
A
Specification
300 mm
600 mm
P10
MWI
MWU
B potentiometer with 10 kΩ transducer 4 … 20 mA transducer 0 … 10 V others on request
OK
0.5
...
C without cable
0.5 m
1 ... 15 m, in steps of 1 m
Additional information
Transducer setting, only with MWI or MWU encoder types
4
Scope of delivery: SG5
Accessories:
Electronic display MA50
Guide roller UR
3 LinearLine | 3.1 Wire-actuated Encoder www.siko-global.com
www.siko-global.com
www.siko-global.com
Advertisement