Wire-actuated encoder SGP/1 robust design with analog output and 6000 mm measurement length
Profile
■
■
■
■
■
■
Robust design
Measurement lengths up to max. 6000 mm
Potentiometer, voltage or power output
Housing made of aluminum and plastic
Potentiometer/resistance range adapted to actual measurement length via an integrated gear
Various wire types
85
45
5
220° 45°
18
5
35
25 type of connection E1
55
41 type of connection EX
M 12 x1 rotatable
Rotating changes the readings!
13 wire type
S, SK, P rope fixture
GW
8.5
4.5
wire type
S, SK, P rope fixture
HK wire type
S/FLEX, SK/FLEX rope fixture
GW
11
M6 wire type
S/FLEX, SK/FLEX rope fixture
HK
11
~8
10 158/19
04.07.2008
19.06.2019
Weißer
Kreutzmann
Katalogzeichnung
SGP/1
3 LinearLine | 3.1 Wire-actuated Encoder
203627 www.siko-global.com
1
Wire-actuated encoder SGP/1 robust design with analog output and 6000 mm measurement length
Mechanical data
Feature
Housing
Wire design
Extension force
Measured distance/ rope drum revolution
Acceleration
Weight
Technical data aluminum/plastic
ø0.54 mm
ø0.87 mm
ø1.05 mm
≥8 N
200 mm
≤23.5 m/s
2
~0.7 kg
■ max. travel speed
Measuring range [mm]
Travel speed [mm/s]
Additional information steel wire (stainless) steel wire (stainless), plastic coated
Paraleine
750
≤200
1000
≤300
1250
≤300
1500
≤400
1750
≤490
2000
≤500
2250
≤600
2500
≤700
2750
≤800
3000
≤800
3250
≤900
3500 6000
≤1000 ≤1000
Electrical data
■
Encoder potentiometer
Feature
Power rating
Resistance
Resistance tolerance
Linearity tolerance
Technical data
2 W at 70 °C
1 kΩ
2 kΩ
5 kΩ
10 kΩ
±5 %
±0.25 %
■
Transducer, power output
Feature
Operating voltage
Output current
Technical data
10 … 30 V DC
4 … 20 mA
Additional information
P01
P02
P05
P10
Additional information between I+ and I-, load ≤500 Ω
■
Transducer, voltage output
Feature
Operating voltage
Output voltage
Resistance
Load
Technical data
15 … 28 V DC
0 … 10 V DC
2 … 10 kΩ
≤15 mA
Additional information at 3 mA without load against GND
* Measurement transducers permit optimum adjustment of the output current and output voltage to the measuring range. The measurement transducer is pre-set at the works so that an output signal of 4 … 20 mA
(MWI) or 0 … 10 V DC (MWU) is available.
System data
Feature
Repeat accuracy
Travel speed
Technical data
~0.5 mm see table
Ambient conditions
Feature
Ambient temperature
Protection category
Technical data
-20 … 80 °C
-40 … 80 °C
IP65 (potentiometer part)
Additional information per direction of approach
Additional information
T1
T2 (draw-in speed ≤800 mm/s)
EN 60529
2
3 LinearLine | 3.1 Wire-actuated Encoder www.siko-global.com
Wire-actuated encoder SGP/1 robust design with analog output and 6000 mm measurement length
Pin assignment
■
Potentiometric outputs P10
Signal
Po
Pe
S nc
E1 (terminal )
3
1
2
■
MWI transducer
Signal
I+
Inc nc
2
3
E1 (terminal)
1
■
MWU transducer
Signal
+24 V DC
GND
U out nc
E1 (terminal)
1
2
3
3
4
EX (connector pin)
1
2
2
3
4
EX (connector pin)
1
3
4
EX (connector pin)
1
2 potentiometric outputs P01, P05, P10
Pe
... kΩ
S
Po transducer MWI
10 kΩ
R/I transformer
I+
Itransducer MWU
10 kΩ
+UB
Uout
GND
R/U transformer
Hint for mounting
When securing the wire it must be ensured that the wire is straight and vertical in relation to the wire outlet.
Recommendation: Only select the starting position after an unwound length of approx. 5 mm. This prevents the wire hitting the end stop when it is rewound. initial position final position symbolic depiction
~5 mm measuring range
≤ extension length
3
3 LinearLine | 3.1 Wire-actuated Encoder www.siko-global.com
Wire-actuated encoder SGP/1 robust design with analog output and 6000 mm measurement length
Order
■
Ordering table
Feature
Measuring range
Rope fixture
Wire design
Ordering data
...
A
Specification
750 ... 6000 mm, in steps of 250 mm
GW
HK
B wire suspension with thread wire suspension with hook
S
SK
P
S/FLEX
SK/FLEX
C stainless steel rope stainless steel rope, plastic-coated para-line, non-conducting, signal color stainless steel rope, flexible rope outlet stainless steel rope, plastic-coated, flexible rope outlet
Additional information measuring range ≤ 6000 mm measuring range ≤ 4000 mm measuring range ≤ 2800 mm measuring range ≤ 6000 mm measuring range ≤ 4000 mm cable ø 3-6.5 mm Type of connection
Potentiometer type
Analog output
Operating temperature
E1
EX
02
03
MWI
MWU
P01
P05
P10
T1
T2
■
Order key
SGP/1 -
A
-
B
-
C
-
D cable gland PG7 for M12 connector
E 10 helices/wire
10 helices/hybride
F 4 … 20 mA transducer
0 … 10 V transducer potentiometer 1 kΩ potentiometer 5 kΩ potentiometer 10 kΩ
G -20 … +80 °C
-40 … +80 °C
D
-
E
-
F
-
G
(P01, P05, P10)
(P01, P05, P10)
≤ feed speed 800 mm/s
4
Scope of delivery: SGP/1, Mounting instructions
Accessories:
Electronic display MA50
Guide roller UR
Wire extension piece SV
Mating Connector Overview
Mating connector, EX, 4-pole, socket
3 LinearLine | 3.1 Wire-actuated Encoder www.siko-global.com
www.siko-global.com
www.siko-global.com
www.siko-global.com
Order key 83419 www.siko-global.com
Advertisement