Doc. No.VQC5000V-OMU0002
Solenoid Valve
PRODUCT NAME
VQC5000Series
MODEL / Series / Product Number
Contents
Safety Instructions ---------------------------------------------------------------------------- 2,3
Design / Selection ---------------------------------------------------------------------------- 4 to 6
Mounting ---------------------------------------------------------------------------------------- 6
Piping -------------------------------------------------------------------------------------------- 6,7
Wiring -------------------------------------------------------------------------------------------- 7
Lubrication -------------------------------------------------------------------------------------- 7
Air Supply --------------------------------------------------------------------------------------- 8
Operating Environment ---------------------------------------------------------------------- 8
Maintenance ------------------------------------------------------------------------------------ 9
Specific Product Precautions --------------------------------------------------------------- 10,11
Manifold option / Assembly Part No.--------------------------------------------------------- 12
Construction ------------------------------------------------------------------------------------- 13
List of valves,options,and Mounting Bolts-------------------------------------------------- 14
Electrical Wiring Specifications---------------------------------------------------------------- 15 to 19
F kit --------------------------------------------------------------------------------------- 15
P kit --------------------------------------------------------------------------------------- 16
T kit --------------------------------------------------------------------------------------- 17
L kit --------------------------------------------------------------------------------------- 18
M kit --------------------------------------------------------------------------------------- 19
Trouble shooting ------------------------------------------------------------------------------- 20,21
-1-
No.VQC5000V-OMU0002
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
hazard with the labels of “Caution,” “Warning” or “Danger.”
They are all important notes for safety and must be followed in addition to International Standards
(ISO/IEC)
*1)
, and other safety regulations
*1) ISO 4414: Pneumatic fluid power -- General
General rules relating to systems.
IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)
ISO 10218-1992: Manipulating industrial robots
etc.
Manipulating industrial robots -Safety.
General requirements)
Caution
Warning
Danger
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or
Warning result in death or serious injury.
Danger indicates a hazard with a medium level of risk which, if not avoided, could indicates a hazard with a high level of risk which, if not avoided, in death or
Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific designs the equipment or decides its specifications based on
The expected performance and safety assurance of the equipment will be the responsibility of the person who
This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.
with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly.
The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.
When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions
of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to
direct sunlight.
navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.
An application which could have negative effects on people, property, or animals requiring special safety analysis.
requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.
- 2 -
No.VQC5000V-OMU0002
Safety Instructions
Caution
1.The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in or a contract if necessary.
If anything is unclear, contact your nearest sales branch.
Limited warranty and Disclaimer/Compliance Requirements
The product used is subject to the follow
Requirements”.
Read and accept them before using the product.
1.The warranty period of the product is 1 year in service or 1.5 years after the product is delivered,whichever is first.
∗∗∗∗
2)
Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.
damage reported within the warranty period which is clearly our responsibility,
a replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage
incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products.
Prior to using SMC products, please read and understand the warranty terms and disclaimers
∗∗∗∗
2) Vacuum pads are excluded from this 1 year warranty.
a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited
warranty.
Compliance Requirements
The use of SMC products with production equipment for the manufacture of weapons of mass or technology from one country to another are govemed by the security laws and regulation of the countries involved in the transaction. Prior to the product to another country, assure that all local rules goveming that export are known and f ollowed.
- 3 -
No.VQC5000V-OMU0002
VQC5000 Series
Precautions for 5 Port Solenoid Valve 1111
Be sure to read before handling. Refer to main text for detailed precautions on every series.
Design / Selection
Warning
1. Confirm the specifications
Products represented in this catalog are designed only for use in compressed air systems (including vacuum).
Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to the specifications.)
Please contact SMC when using a fluid other than compressed air (including vacuum).
We do not guarantee against any damage if the product is used outside of the specification range.
2. Actuator drive
When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures (cover
installation or approach prohibition) to prevent potential danger caused by actuato r operation.
3. Intermediate stops
For 3-position closed center or double check valve type, it is difficult to make a piston stop at the required position accurately due to the compressibility of air.
Furthermore, since valves and cylinders are not guaranteed for zero air leakage, it may not be possible to hold a stopped position for an extended period of time. Please contact SMC if it is necessary to hold a stopped position for an extended period of time.
4. Effect of back pressure when using a manifold.
Use caution when valves are used on a manifold, because an actuator may malfunction due to back-pressure. For 3-position exhaust center valve of single acting cylinder, take appropriate measures to prevent the malfunction by using it with an individual exhaust manifold .
5. Holding pressure (including vacuum).
Since the valve are subject to air leakage, they cannot be used for applications such as holding pressure
(including vacuum) in a pressure vessel.
6. Not suitable for use as an emergency shut-off valve, etc.
The valves listed in this instruction manual are not designed for safety applications such as an emergency shutoff valve. If the valves are used for the mentioned applications, additional safety measures should be adopted.
7. Release of residual pressure
For maintenance purposes install a system for
releasing residual pressure. Especially in the case of
3-position closed center valve or double check valve type, ensure that the residual pressure between the valve and the cylinder is released.
8. Ventilation
Provide ventilation when using a valve in a confined area, such as in a closed control panel. For example, install a ventilation opening, etc. in order to prevent pressure from increasing inside of the confined area and to release the heat generated by the valve.
9.Regarding a vacuum switch valve
For maintenance purposes install a system for releasing residual pressure.
10. Double solenoid type
When using the double solenoid type for the first time, actuators may travel in an unexpected direction depending on the switching position of the valve.
Implement measures to prevent any danger from occurring when operating the actuator.
11. Ventilation
Provide ventilation when using a valve in a confined area, such as in a closed control panel. For example, install a ventilation opening, etc. in order to prevent pressure from increasing inside of the confined area and to release the heat generated by the valve.
12.Extended periods of continuous energization
・
If a valve will be continuously energized for an extended period of time, the temperature of the valve will increase due to the heat generated by the coil.
This will likely adversely affect the performance of the solenoid valve and any nearby peripheral equipment.
Therefore, when it is continuously energized or the energized period per day is longer than the de-energized period use either: DC specification, power-saving type. Also, please contact SMC because depending on the application, there may be additional valves not mentioned above that may be used.
・
For applications such as mounting a valve on a control panel, incorporate measure to limit the heat radiation so that it is within the operation temperature range. For example, the temperature will be high when a 3 station manifold.
13.Do not disassemble the product of make any modifications, including
additional machining.
It may cause human injury and/or an accident.
Caution
1. Precautions on 2-position double solenoid valve
If a double solenoid valve is operated with momentary energization, it should be energized for at least 0.1 second. However, depending on the piping conditions, cylinder may malfunction even when the double solenoid valve is energized for 0.1 second or longer. In this case, energize the double solenoid valve until the cylinder is exhausted completely.
2. Leakage voltage
Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a
C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit.
The suppressor residual leakage voltage should be as follows. Should be3% or less of rated voltage.
- 4 -
No.VQC5000V-OMU0002
VQC5000 Series
Design / Selection
Caution
3. Surge voltage suppressor
1) A surge voltage suppressor built into the valve is intended to protect the output contacts so that the surge generated inside valve does not adversely affect the output contacts. Therefore, if an overvoltage or overcurrent is received from an external peripheral device, the surge voltage protection element inside the valve is overloaded, causing the element to break. In the worst case, the electric circuit enters the short-circuit status by the breakage. If the energizing continues in this status, a large current flows. This may cause secondary damage to the output circuit, external peripheral device, or valve, and may also cause fire accident. So, take appropriate protective measures, such as installation of an overcurrent protection circuit in the power supply or drive circuit to maintain the sufficient safety.
2) If a surge protection circuit contains nonstandard diodes, such as Zener diodes or varistor, a residual voltage that is in proportion to the protective circuit and the rated voltage will remain. Therefore, take into consideration the surge voltage protection of the controller.In the case of diodes, the residual voltage is approximately 1 V.
4. Surge voltage intrusion
With non-polar type solenoid valves, at times of sudden interruption of the loading power supply, such as emergency shutdown, surge voltage intrusion may be generated from loading equipment with a large capacity (power consumption), and the solenoid valve in a deenergized state may switch over (see
Figure 1). When installing a breaker circuit for the loading power supply, consider using a solenoid valve with polarity (with polarity protection diode), or install a surge absorption diode between the loading equipment COM line and the output equipment COM line (see Figure 2).
- 5 -
Precautions for 5 Port Solenoid Valve 2222
Be sure to read before handling. Refer to main text for detailed precautions on every series.
No.VQC5000V-OMU0002
VQC5000 Series
Precautions for 5 Port Solenoid Valve 3333
Design / Selection
Caution
5. Operation in a low temperature condition
It is possible to operate a valve in extreme temperature, as low as -5 o
C. Take appropriate measures to avoid freezing of drainage, moisture etc. in low temperature.
6. Operation for air blowing
When using a solenoid valve for air blowing, use an external pilot type. Use caution because the pressure drop caused by the air blowing can have an affect on the internal pilot type valve when the internal pilot type valves and external pilot type valves are used on the same manifold.
Additionally, when compressed air within the pressure range of the established specifications is supplied to the external pilot type valve’s port, and a double solenoid valve is used for air blowing, the solenoids should normally be energized when air is being blown.
7. Mounting orientation
Rubber seal : Mounting orientation is free.
Metal seal : Mounting orientation of a single solenoid is universal.No specific orientation is necessary. When installing a double solenoid or a 3-position configuration, mount the valve so that spool valve is horizontal.
8. Initial lubrication of main valve
The following initial lubricant has already been applied to the main valve.
Rubber seal, spool valve: Grease Please consult with SMC, as there are some standard valve products that use fluorine grease for food processing equipment (NSF H-1).
Metal seal, spool valve: Turbine oil
Turbine oil is applied to the spool valve of a metal seal type. Therefore, turbine oil may seep out when a new product is delivered, or while the valve is stored.
Mounting
Warning
1. Operation manual
Install the products and operate them only after reading the operation manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary.
2. Ensure sufficient space for maintenance activities.
When installing the products, allow access for maintenance.
3. Tighten threads with the proper tightening torque.
When installing the products, follow the listed torque specifications.
Be sure to read before handling. Refer to main text for detailed precautions on every series.
Mounting
4. If air leakage increases or equipment does not operated properly, stop
operation.
Check mounting conditions when air and power supplies are connected. Initial function and leakage tests should be performed after installation.
5. Painting and coating
Warnings or specifications printed or affixed to the product should not be erased, removed or covered up.
Please consult with SMC before applying paint to resinous parts, as this may have an adverse effect due to the solvent in the paint.
Piping
Caution
1. Refer to the Fittings and Tubing
Precautions for handling one-touch fittings.
2. Preparation before piping
Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.
3. Wrapping of pipe tape
When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not enter the piping. Also, if pipe tape is used, leave 1 thread ridges exposed at the end of the threads
.
4. Closed center
For closed center, check the piping to prevent air leakage from the piping between the valve and the cylinder.
5. Connection of fittings
When screwing fittings into valves, tighten as follows.
When using a fitting other than SMC fitting, follow the instructions given by relevant fitting manufacturer.
1) For the fitting with sealant R or NPT, first, tighten it by hand, then use a wrench appropriate for the hexagon flats of the body to tighten it a further two or three turns.
For a tightening torque guide, refer to the table below.
Connection thread size (R,NPT)
1/8
1/4
3/8
1/2
3/4
Proper tightening torque
(N
・ m)
3 to 5
8 to 12
15 to 20
20 to 25
28 to 30
- 6 -
No.VQC5000V-OMU0002
VQC5000 Series
Precautions for 5 Port Solenoid Valve 4444
Be sure to read before handling. Refer to main text for detailed precautions on every series.
Piping
Caution
3) If the fitting is tightened with excessive torque, a large amount of sealant will seep out. Remove the excess sealant.
4) Insufficient tightening may cause seal failure, or loosen the threads.
5) Reuse
(1) Normally, fittings with a sealant can be reused 2 to
3 times.
(2) To prevent air leakage through the sealant, remove any loose sealant stuck to the fitting by blowing air over the threaded portion.
(3) If the sealant no longer provides effective sealing, wrap sealing tape over the sealant before reusing.
Do not use the sealant in any form other than a tape type.
(4) Once the fitting has been tightened, backing it out to its original position often causes the sealant to become defective. Air leakage will occur.
6. Uni thread fittings
1) First, tighten the threaded portion by hand, then use a proper wrench, which could be suitable for the width across flats of the hexagon body, to tighten it further at a wrench tightening angle shown below.
As a reference value for the tightening torque, refer to the table below.
Connection Female Thread: Rc, NPT, NPTF
Uni thread size
1/8
Wrench tightening angle after tightened by hand
(deg)
30 to 60
Tightening torque
(N
・ m)
3 to 5
1/4 30 to 60 8 to 12
3/8
1/2
15 to 45
Connection Female Thread : G
Uni thread size
Wrench tightening angle after tightened by hand
(deg)
1/8
15 to 30
30 to 45
14 to 16
20 to 22
Tightening torque
(N
・ m)
3 to 4
4 to 5 1/4 15 to 30
3/8 15 to 30 8 to 9
1/2 15 to 30 14 to 15
2) The gasket can be recycled up to 6 to 10 times. It can be replaced easily when it has sustained damage. A broken gasket can be removed by holding it and then turning it in the same direction as loosening the thread.
If gasket is difficult to remove, cut it with nippers, etc. In such a case, use caution not to scratch the seat face because the seat face of 45° gasket of fitting is t he sealing face.
7. Piping to products
When piping to a product, refer to the operation manual to avoid mistakes regarding the supply port, etc.
Wiring
Warning
1. The solenoid valve is an electrical product. For safety, install an appropriate fuse and circuit breaker before use.
Caution
1. Applied voltage
When electric power is connected to a solenoid valve, be careful to apply the proper voltage. Improper voltage may cause malfunction or coil damage.
2. Check the connections.
Check if the connections are correct after completing all wiring.
3. External force applied to lead wire
If an excessive force is applied to the lead wire, this may cause faulty wiring. Take appropriate measures so that a force of 30 N or more is not applied to the lead wire.
When instructions are given to the Specific Product
Precautions, follow these specifications.
Lubrication
Warning
1. Lubrication
[Rubber seal]
1) The valve has been lubricated for life by the factory and does not require any further.
2) If a lubricant is used in the system, use class 1 turbine oil (no additive), ISO VG32. For details about lubricant manufacturers’ brands, refer to SMC website. Additionally, please contact SMC for details about class 2 turbine oil (with additives) ISO VG32.
Once lubricant is utilized within the system, since the original lubricant applied within the product during manufacturing will be washed away, please continue to supply lubrication to the system. Without continued lubrication, malfunctions could occur.
[Metal seal]
1) These valves can be used without lubrication.
2) If a lubricant is used in the system, use class 1 turbine oil (no additive), ISO VG32. For details about lubricant manufacturers’ brands, refer to SMC website. Additionally, please contact SMC for details about class 2 turbine oil (with additives) ISO
VG32.
2. Lubrication amount
If the lubrication amount is excessive, the oil may accumulate inside the pilot valve, causing malfunction or response delay. So, do not apply a large amount of oil. When a large amount of oil needs to be applied, use an external pilot type to put the supply air on the pilot valve side in the non-lube state. This prevents accumulation of oil inside the pilot valve.
- 7 -
No.VQC5000V-OMU0002
VQC5000 Series
Precautions for 5 Port Solenoid Valve 5555
Be sure to read before handling. Refer to main text for detailed precautions on every series.
Air Supply
Warning
1. Type of fluids
Please consult with SMC when using the product in applications other than compressed air.
2.
When there is a large amount of drainage.
Compressed air containing a large amount of drainage can cause malfunction of pneumatic equipment. An air dryer or water separator should be installed upstream from filters.
3.
Drain flushing
If condensation in the drain bowl is not emptied on a regular basis, the bowl will overflow and allow the condensation to enter the compressed air lines. It causes malfunction of pneumatic equipment. If the drain bowl is difficult to check and remove, installation of a drain bowl with an auto drain option is recommended.
For compressed air quality, refer to SMC’s Best
Pneumatics catalog.
4. Use clean air
Do not use compressed air that contains chemicals, synthetic oils including organic solvents, salt or corrosive gasses, etc., as it can cause damage or malfunction.
Caution
1. When extremely dry air is used as the fluid, degradation of the lubrication properties in side the equipment may occur, resulting in reduced reliability (or reduced service life) of the equipment.
Please consult with SMC.
2. Install an air filter.
Install an air filter upstream near the valve. Select an air filter with a filtration size of 5
µ m or smaller.
3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator.
Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment such as valves. Therefore, take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer, or water separator.
4. If excessive carbon powder is seen, install a mist separator on the upstream side of the valve.
If excessive carbon dust is generated by the compressor, it may adhere to the inside of a valve and cause it to malfunction.
For compressed air quality, refer to SMC’s Best
Pneumatics catalog.
- 8 -
Operating Environment
Warning
1. Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these .
2. Products with IP65 and IP67 enclosures (based on
IEC60529) are protected against dust and water, however, these products cannot be used in water.
3. Products compliant to IP65 and IP67 satisfy the specifications through mounting. Be sure to read the Precautions for each product.
4. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction.
5. Do not use in a place subject to heavy vibration and/or shock.
6. The valve should not be exposed to prolonged sunlight. Use a protective cover.
7. Remove any sources of excessive heat.
8. If it is used in an environment where there is possible contact with oil, weld spatter, etc., exercise preventive measures.
9. When the valve is mounted in a control panel or its energized for a long time, make sure ambient temperatures is within the specification of the valve.
Caution
1. Temperature of ambient environment
Use the valve within the range of the ambient temperature specification of each valve. In addition, pay attention when using the valve in environments where the temperature changes drastically.
2. Humidity of ambient environment
When using the valve in environments with low humidity, take measures to prevent static.
If the humidity rises, take measures to prevent the adhesion of water droplets on the valve.
No.VQC5000V-OMU0002
VQC5000 Series
Precautions for 5 Port Solenoid Valve 6666
Be sure to read before handling. Refer to main text for detailed precautions on every series.
Maintenance
Warning
1. Perform maintenance inspection according to the procedures indicated in the operation manual.
If handled improperly, malfunction and damage of machinery or equipment may occur.
2. Removal of equipment, and supply/exhaust of compressed air
When components are removed, first confirm that measures are in place to prevent workpieces from dropping, run-away equipment, etc. Then, cut off the supply pressure and electric power, and exhaust all compressed air from the system using the residual pressure release function.
For 3-position closed center type, exhaust the residual pressure between the valve and the cylinder.
When the equipment is operated after remounting or replacement, first confirm that measures are in place to prevent lurching of actuators, etc. Then, confirm that the equipment is operating normally.
3. Low frequency operation
Valves should be operated at least once every 30 days to prevent malfunction. (Use caution regarding the air supply.)
4. Manual override operation
When the manual override is operated, connected equipment will be actuated.
Operate after safety is confirmed.
5. If the volume of air leakage increases or the valve does not operate normally, do not use the valve.
Perform periodic maintenance of the valve to confirm the operating condition,
and if there is any air leakage.
Caution
1. Drain flushing
Remove drainage from the air filters regularly.
2. Lubrication
In the case of rubber seals, once lubrication has been started, it must be continued.
Use class 1 turbine oil (with no additive), VG32 because if other lubricant oil is used, it may cause malfunction. Please contact SMC for suggested class
2 turbine oil (with additive), VG32.
3. Manual override operation
When switching a double solenoid valve by the manual override operation, instantaneous operation may cause a malfunction of the cylinder.
It is recommended that the manual override be held until the cylinder reaches the stroke end position.
- 9 -
No.VQC5000V-OMU0002
VQC5000 series
Specific Product Precautions 1
Be sure to read this before handling
Continuous Duty
When the product is continuously energized for a
Valve Mounting correctly, securely tighten the mounting screws long period of time (10 minutes or longer), select
After confirming that the gasket is installed according to the tightening torque shown the low wattage type (DC specification). The AC below. type cannot be continuously energized for 10
Proper tightening torque [N.m] minutes or longer. If anything is unclear, please
1 to 1.8 contact SMC.
Manual Override
Since connected equipment will operate when the manual override is activated, confirm that conditions are safe prior to activation.
Push type(Tool required)
Push down the manual override button with a small screwdriver, etc., until it stops. The manual override will return when released.
Locking type (Tool required)
Lead Wire Connection
Plug-in sub-plate (With terminal block)
• If the junction cover ① of the sub-plate is removed, you can see the plug-in type terminal block ② mounted inside the sub-plate.
Push down the manual override button with a small flat head screwdriver until it stops, and turn it clockwise 90° to lock it. Turn it counterclockwise to release it.
Locking type (Manual)
• The terminal block is marked as follows.
Connect wiring to each of the power supply terminals.
Push down the manual override button with a small flat head screwdriver or with your finger until it stops, and turn it clockwise 90° to lock it. Turn it countercl ockwise to release it.
Note 1) There is no polarity. It can also be used as –COM.
Note 2) The sub-plate is double wired even for the VQC510
0
1
.
Applicable terminal: 1.25-3s, 1.25Y-3, 1.25Y-3N,
Do not apply excessive torque when turning the manual override.[0.1 N·m or less]
1.25Y-3.5
- 10 -
VQC5000V-OMU0002
VQC5000 series
Specific Product Precautions 2
Be sure to read this before handling
Installation and Removal of Light Cover
Installation / Removal of light cover
Internal Wiring Specifications
■ Removal
. To remove the pilot cover pull it straight off. If it is pulled off at an angle, the pilot valve may be damaged or the protective O-ring may be scratched.
■ Installation
Place the cover straight over the pilot assembly so that the pilot valve is not touched, and push it until the cover hook locks without twisting the protective O-ring. (When pushed in, the hook opens and locks automatically.)
T
• Removal
Replacement of Pilot Valve
1) Remove the mounting screw that holds the pilot valve using a small screwdriver.
• Installation
1) After confirming the gasket is correctly placed under the valve, securely tighten the bolts with the proper torque shown in the table below.
Proper tightening torque [N.m]
0.1 to 0.13
Plug Lead Type
Attaching and detaching connectors
• To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever’s pawl is pushed into the groove and locks.
• To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out.
Note) Do not pull on the lead wires with excessive force.
This can cause faulty and/or broken contacts.
・
How to Calculate the Flow Rate
For obtaining the flow rate, refer to the WEB catalog or the Best Pneumatics No. 1.
- 11 -
VQC5000V-OMU0002
Manifold Options
Manifold Assembly Part No.
D-Side end plate assembly Manifold block assembly
D-side end plate assembly part No. Manifold block assembly part No.
U-side end plate assembly
U-side end plate assembly part No.
Replacement Parts
Tie-rod assembly part No. (2 units)
- 12 -
VQC5000V-OMU0002
Construction
- 13 -
VQC5000V-OMU0002
- 14 -
VQC5000V-OMU0002
- 15 -
VQC5000V-OMU0002
- 16 -
VQC5000V-OMU0002
- 17 -
VQC5000V-OMU0002
- 18 -
VQC5000V-OMU0002
- 19 -
VQC5000V-OMU0002
Trouble
Operating failure
The air supply does not switch the valve
.
Response failure
The operation of the valve is delay.
When the valve is failing, use this flow chart to clarify the cause of the failure and take countermeasures appropriate for the cause.
Can manual override move the valve
NO
YES
Does the indicator light keep turning on during energization?
YES
NO
Possible cause Countermeasures
1) Sliding failure or stick of main valve.
A foreign material included in supplied air is caught by main valve and makes the main valve unable to slide smoothly or sticky.
2) Pressure drop.
The pressure of supplied air lowers the valve which can operate the valve (min. operating pressure).
1) Failure of electrical system
•
Incorrect wiring
•
Blow of fuse and breakage of lead wire.
•
Poor contact at contactor wire or connection part
•
Failure of sequencer
•
Lack of supply voltage
1) Voltage drop
Even if the indicator light keeps turning on, the valve can’t be operated due to the voltage drop.
2) Leakage current
When the power turns off, the valve can’t be switched due to residual voltage.
•
Replace with new valve.
•
Clean the supplied air.
Raise the pressure of supplied air up to operating pressure of the valve.
Check these items and replace part and re-wire positively.
•
Check the voltage and if it is not enough to operate the valve, take appropriate measures.
•
Confirm the residual voltage is follows.
•
DC is 3% or less of rated voltage.
3) Failure of pilot valve
•
Foreign matter caught in
core of pilot valve.
•
Disconnection coil
wire of pilot valve
• Swelled out poppet
of pilot valve
•
Burnt coil of pilot valve
(Higher voltage or wrong coil used, Coil splashed by water)
1) Current leakage
When the power turns off, the valve can be switched late due to residual voltage.
2) Clogging of filter element of manifold.
3) Sliding failure or stick of main valve.
A foreign material included in supplied air is caught by main valve and makes the main valve unable to slide smoothly or sticky.
•
Replace part or re-wire positively.
•
Check voltage. Replace valve.
(Pilot valve)
•
Replace valve (pilot valve). Protect the valve so that water does not splash the coil.
•
Confirm the residual voltage is follows.
•
DC is 3% or less of rated voltage.
•
Clean the element or replace with new element.
•
Replace with new valve.
•
Clean the supplied air.
- 20 -
No.VQC5000V-OMU0002
Trouble
Air leakage
When the valve is failing, use this flow chart to clarify the cause of the failure and take countermeasures appropriate for the cause.
Confirm there is air leakage.
1. Between valve and base
2. Air leaks through One-touch fitting
3. Air leaks through exhaust port (R port)
Note) The valve with metal seal allows air leakage from main valve approx. 200Ncc for each port ( at 0.5MPa). The air leakage within the range should not be considered abnormal.
4. Air leaks through manifold.
Possible cause Countermeasures
1-1) Looseness of clamp screw or mounting bolt.
Give more torque to clamp screw.
・
VQC5000 : 1.0
~
1.8N
・ m
If the damage is seen on the gasket, replace with new gasket.
1-2) Caught gasket Replace with new gasket.
1-3) Intrusion of foreign matter To remove foreign matter by air blow of piping and when a gasket damaged, replace with new gasket.
2-1) Tube is not inserted
enough deeply.
2-2) Tube has a flaw.
Check these items and replace part and re-wire positively.
2-3) Tube is cut diagonally.
2-4) Packing of one touch fitting is damaged.
3-1) Looseness of clamp screw or mounting bolt.
Replace with one-touch fitting.
Give more torque to clamp screw.
Tightening torque
・
VQC5000 : 1.0
~
1.8N
・ m
If the damage is seen on the gasket, replace with new gasket.
3-2) A foreign material included into supplied air is caught by the main valve and increases internal air leakage.
•
•
Replace with new valve.
Clean the supplied air.
Insufficient bolt tightening After stopping air and re-tighten the bolts.
- 21 -
No.VQC5000V-OMU0002
S
Revision history
1st printing : UT
4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN
Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362
URL http://www.smcworld.com
Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
© 2011 SMC Corporation All Rights Reserved
No.VQC5000V-OMU0002