Doc. No.SYJ300-OMV0001
Solenoid Valve
PRODUCT NAME
SYJ Series
MODEL/ Series
Contents
Safety Instructions ---------------------------------------------------------------------------- 2,3
Design / Selection ---------------------------------------------------------------------------- 4,5,6
Mounting ---------------------------------------------------------------------------------------- 6
Piping -------------------------------------------------------------------------------------------- 6
Wiring -------------------------------------------------------------------------------------------- 7
Lubrication -------------------------------------------------------------------------------------- 7
Air Supply --------------------------------------------------------------------------------------- 7
Operating Environment ---------------------------------------------------------------------- 7,8
Maintenance ------------------------------------------------------------------------------------ 8
Specific Product Precautions --------------------------------------------------------------- 9 ~16
Construction and optional parts ------------------------------------------------------------ 17~23
Trouble shooting ------------------------------------------------------------------------------- 24,25
-1-
No.SYJ300-OMV0001
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”
They are all important notes for safety and must be followed in addition to International Standards
(ISO/IEC)
*1)
, and other safety regulations.
*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.
ISO 4413: Hydraulic fluid power -- General rules relating to systems.
IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)
ISO 10218: Manipulating industrial robots -Safety.
etc.
Caution
Warning
Warning
indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
Danger
Caution
indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Danger
indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results.
The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product.
This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly.
The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
1.The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.
2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented
and the power from any appropriate source is cut, and read and understand the specific product precautions
of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to
direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,
vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or
other applications unsuitable for the standard specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special safety analysis.
4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.
- 2 -
No.SYJ300-OMV0001
Safety Instructions
Caution
1. The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary.
If anything is unclear, contact your nearest sales branch.
Limited warranty and Disclaimer/Compliance Requirements
The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance
Requirements”.
Read and accept them before using the product.
Limited warranty and Disclaimer
1.The warranty period of the product is 1 year in service or 1.5 years after the product is delivered,whichever is first.
∗
2)
Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility,
a replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage
incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products.
∗
2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited
warranty.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction(WMD) or any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulation of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and f ollowed.
Caution
SMC products are not intended for use as instruments for legal metrology.
Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country.
Therefore, SMC products cannot be used for business or certification ordained by the metrology
(measurement) laws of each country.
- 3 -
No.SYJ300-OMV0001
SYJ Series
3-Port Solenoid Valves Precautions 1
Be sure to read this before handling products.
Design/Selection
1. Confirm the specifications.
Products represented in this catalog are designed only for use in compressed air systems (including vacuum).
Do not operate at pressures, temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction.
(Refer to the specifications.)
Please contact SMC when using a fluid other than compressed air (including vacuum).
We do not guarantee against any damage if the product is used outside of the specification range.
2. Actuator drive
When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures (such as the installation of a cover or the restricting of access to the product) to prevent potential danger caused by actuator operation.
3. Effects of back pressure when using a manifold
Use caution when valves are used on a manifold because actuators may malfunction due to back pressure.
For the single acting cylinder, take appropriate measures to prevent malfunction by using it with an individual EXH spacer assembly, a back pressure check valve, or an individual exhaust manifold.
4. Holding pressure (including vacuum)
Since valves are subject to air leakage, they cannot be used for applications such as holding pressure (including vacuum) in a pressure vessel.
5. Not suitable for use as an emergency shutoff valve, etc.
The valves listed in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in such applications, additional safety measures should be adopted.
6. Release of residual pressure
For maintenance and inspection purposes install a system for releasing residual pressure.
7. Operation in a vacuum condition
When a valve is used for switching a vacuum, take measures to install a suction filter or similar to prevent external dust or other foreign matter from entering inside the valve.
In addition, at the time of vacuum adsorption, be sure to supply a constant supply of vacuum. Failure to do so may result in foreign matter sticking to the adsorption pad or air leakage, causing the workpiece to drop.
8. Regarding vacuum switch valves and vacuum release valves
If a non-vacuum valve is installed in the middle of a piping system that contains a vacuum, the vacuum condition will not be maintained. Use a valve designed for use under vacuum conditions.
9. Ventilation
Provide ventilation when using a valve in a confined area, such as in a closed control panel. For example, install a ventilation opening, etc., in order to prevent pressure from increasing inside of the confined area and to release the heat generated by the valve.
- 4 -
10. Extended periods of continuous energization
If a valve will be continuously energized for an extended period of time, the temperature of the valve will increase due to the heat generated by the coil assembly. This will likely adversely affect the performance of the valve and any nearby peripheral equipment. Therefore, if the valve is to be energized for periods of longer than 30 minutes at a time or if during the hours of operation the energized period per day is longer than the de-energized period, we advise using a power-saving circuit valve.
11. Do not disassemble the product or make any modifications, including additional machining.
Doing so may cause human injury and/or an accident.
No.SYJ300-OMV0001
SYJ Series
3-Port Solenoid Valves Precautions 2
Be sure to read this before handling products.
Design/Selection
1. Leakage voltage
Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a
C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows.
DC coil 3% or less of the rated voltage
AC coil 8% or less of the rated voltage
2. Solenoid valve drive for AC with a solid state output
(SSR, TRIAC output, etc.)
1) Current leakage
When using a snubber circuit (C-R element) for surge protection of the output, a very small amount of electrical current will continue to flow even during the OFF state.
This results in the valve not returning. In a situation where the tolerance is exceeded, as in the above case, take measures to install a bleeder resistor.
2) Minimum allowable load amount (Min. load current)
When the consumption current of a valve is less than the output’s minimum allowable load volume or the margin is small, the output may not switch normally. Please contact
SMC.
3) Solenoid valve with full wave rectifier circuit
When the solenoid valve built-in full wave rectifier circuit with AC specifications is used, a return failure of the solenoid valve may occur depending on the kind of triac output circuit. Carefully check this point when selecting a
SSR or sequencer.
For details, contact the SSR or sequencer manufacturer.
3. Surge voltage suppressor
1) The surge voltage suppressor built into the valve is intended to protect the output contacts so that the surge generated inside valve does not adversely affect the output contacts. Therefore, if an overvoltage or overcurrent is received from an external peripheral device, the surge voltage protection element inside the valve is overloaded, causing the element to break. In the worst case, the breakage causes the electric circuit to enter short-circuit status. If energizing continues while in this state, a large current flows. This may cause secondary damage to the output circuit, external peripheral device, or valve, and may also cause a fire. So, take appropriate protective measures, such as the installation of an overcurrent protection circuit in the power supply or a drive circuit to maintain a sufficient level of safety.
2) If a surge protection circuit contains nonstandard diodes, such as Zener diodes or varistor, a residual voltage that is in proportion to the protective circuit and the rated voltage will remain. Therefore, take into consideration the surge voltage protection of the controller. In the case of diodes, the residual voltage is approximately 1 V.
4. Surge voltage intrusion
With non-polar type solenoid valves, at times of sudden interruption of the loading power supply, such as emergency shutdown, surge voltage intrusion may be generated from loading equipment with a large capacity (power consumption), and a solenoid valve in a de-energized state may switch over
(see Figure 1).
When installing a breaker circuit for the loading power supply, consider using a solenoid valve with polarity (with polarity protection diode), or install a surge absorption diode between the loading equipment COM line and the output equipment COM line
(see Figure 2).
- 5 -
No.SYJ300-OMV0001
SYJ Series
3-Port Solenoid Valves Precautions 3
Be sure to read this before handling products.
Design/Selection
5. Operation in low temperature conditions
It is possible to operate a valve in extreme temperatures, as low as –10°C. Take appropriate measures to avoid the freezing of drainage, moisture, etc., in low temperatures.
6. Operation for air blowing
When using a solenoid valve for air blowing, use an external pilot type. Use caution because the pressure drop caused by the air blowing can have an effect on the internal pilot type valve when internal pilot type valves and external pilot type valves are used on the same manifold.
Additionally, when compressed air within the pressure range of the established specifications is supplied to the external pilot type valve’s port, and a double solenoid valve is used for air blowing, the solenoids should be energized when air is being blown.
7. Mounting orientation
The mounting orientation is universal.
8. Initial lubrication of main valve
The following initial lubricant has already been applied to the main valve.
• Rubber seal, spool valve: Grease
Mounting
1. Operation manual
Install the products and operate them only after reading the operation manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary.
2. Ensure sufficient space for maintenance activities.
When installing the products, allow access for maintenance and inspection.
3. Tighten threads with the proper tightening torque.
When installing the products, follow the listed torque specifications.
4. If air leakage increases or equipment does not operate properly, stop operation.
Check mounting conditions when air and power supplies are connected. Initial function and leakage tests should be performed after installation.
5. Painting and coating
Warnings or specifications printed on or affixed to the product should not be erased, removed, or covered up.
Please consult with SMC before applying paint to resinous parts, as this may have an adverse effect due to the solvent in the paint.
Piping
1. Refer to the Fittings and Tubing Precautions for handling One-touch fittings
2. Preparation before piping
Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil, and other debris from inside the pipe.
3. Winding of sealant tape
When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not enter the piping. Also, if sealant tape is used, leave 1 thread ridge exposed at the end of the threads.
4. Connection of piping and fittings
When screwing piping or fittings into the valve, tighten them as follows.
1) When using SMC’s M5 fittings, follow the procedures below to tighten them.
• Connection thread: M3
First, tighten by hand, then use a suitable wrench to tighten the hexagonal portion of the body an additional
1/4 turn.
The reference value for the tightening torque is 0.4 to 0.5
N·m.
• Connection thread: M5
First, tighten by hand, then use a suitable wrench to tighten the hexagonal portion of the body an additional
1/6 to 1/4 turn.
The reference value for the tightening torque is 1 to 1.5
N·m.
• When using a fitting other than an SMC fitting, follow the instructions given by the fitting manufacturer.
2) For a fitting with sealant R or NPT, first, tighten it by hand, then use a suitable wrench to tighten the hexagonal portion of the body an additional two or three turns. For the tightening torque, refer to the table below.
Connection thread size (R, NPT)
1/8
1/4
Proper tightening torque (N·m)
3 to 5
8 to12
3) If the fitting is tightened with excessive torque, a large amount of sealant will seep out. Remove the excess sealant.
4) Insufficient tightening may cause seal failure or loosen the threads.
5) For reuse
(1) Normally, fittings with a sealant can be reused up to 2 to
3 times.
(2) To prevent air leakage through the sealant, remove any loose sealant stuck to the fitting by blowing air over the threaded portion.
(3) If the sealant no longer provides effective sealing, wind sealing tape over the sealant before reusing. Do not use any form of sealant other than the tape type of sealant.
(4) Once the fitting has been tightened, backing it out to its original position often causes the sealant to become defective. Air leakage will occur.
5. Piping to products
When piping to a product, refer to the operation manual to avoid mistakes regarding the supply port, etc
- 6 -
No.SYJ300-OMV0001
SYJ Series
3-Port Solenoid Valves Precautions 4
prevents the accumulation of oil inside the pilot valve.
Be sure to read this before handling products.
Air Supply Wiring
1. The solenoid valve is an electrical product. For safety, install an appropriate fuse and circuit breaker before use.
1. Polarity
1. Type of fluids
2.
Please consult with SMC when using the product in applications other than compressed air.
When there is a large amount of drainage
Compressed air containing a large amount of drainage can cause the malfunction of pneumatic equipment. An air dryer or water separator should be installed upstream from filters.
3. Drain flushing When connecting power to a solenoid valve with a DC
If condensation in the drain bowl is not emptied on a regular specification and a light or surge voltage suppressor, check for basis, the bowl will overflow. This may cause the malfunction of polarity. If there is polarity, take note of the following. pneumatic equipment. If the drain bowl is difficult to check and Without diode to protect polarity: remove, the installation of a drain bowl with an auto drain option If a mistake is made regarding the polarity, damage may occur to is recommended. the diode in the valve, the switching element in the control device,
For compressed air quality, refer to the SMC Best Pneumatics No. 6 power supply equipment, etc.
With diode to protect polarity: catalog.
4. Use clean air. If the polarity connection is wrong, the valve will not operate.
2. Applied voltage Do not use compressed air that contains chemicals, synthetic oils that include organic solvents, salt, corrosive gases, etc., as When electric power is connected to a solenoid valve, be careful to it can cause damage or malfunction. apply the proper voltage. Improper voltage may cause malfunction or coil damage.
3. Check the connections.
Check if the connections are correct after completing all wiring.
4. External force applied to the lead wire
If an excessive force is applied to the lead wire, this may cause faulty wiring. Take appropriate measures so that a force of 30 N or more is not applied to the lead wire.
Lubrication
1. Lubrication
1. When extremely dry air is used as the fluid, degradation of the lubrication properties inside the equipment may occur, resulting in reduced reliability
(or reduced service life) of the equipment. Please consult with SMC.
2. Install an air filter.
Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 μm or smaller.
3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator.
[Rubber seal]
Compressed air that contains a large amount of drainage can
1) All valves have been lubricated for life by the manufacturer and therefore do not require lubrication cause the malfunction of pneumatic equipment, such as valves.
Therefore, take appropriate measures to ensure air quality, such while in service.
2) If a lubricant is used in the system, use class 1 turbine oil
(no additives), ISO VG32. For details about lubricant manufacturers’ brands, refer to the SMC website. as by providing an aftercooler, air dryer, or water separator.
4. If an excessive amount of carbon powder is present, install a mist separator on the upstream side of the valve.
Additionally, please contact SMC for details about class 2
If excessive carbon dust is generated by the compressor, it may turbine oil (with additives) ISO VG32.Once lubricant is adhere to the inside of a valve and cause it to malfunction. utilized within the system, since the original lubricant
For compressed air quality, refer to the SMC Best Pneumatics No. 6 applied within the product during manufacturing will be catalog. washed away, please continue to supply lubrication to the system. Without continued lubrication, malfunctions could occur.If turbine oil is used, refer to the Safety Data Sheet
(MSDS) of the oil.
2. Lubrication amount
If the lubrication amount is excessive, the oil may accumulate
Operating Environment
1. Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, water steam, or inside the pilot valve, causing malfunction or response delay.
So, do not apply a large amount of oil. When a large amount of oil needs to be applied, use an external pilot type to put the supply air on the pilot valve side in the non-lube state. This where there is direct contact with any of these.
- 7 -
No.SYJ300-OMV0001
SYJ Series
3-Port Solenoid Valves Precautions 5
Be sure to read this before handling products.
Operating Environment
2. Products with IP65 and IP67 enclosures (based on
IEC60529) are protected against dust and water.
However, these products cannot be used in water.
3. Products compliant with IP65 and IP67 satisfy the product specifications when mounted properly. Be sure to read the precautions for each product.
4. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction.
5. Do not use in a place subject to heavy vibration and/or shock.
6. The valve should not be exposed to prolonged sunlight. Use a protective cover. Note that the valve is not for outdoor use.
7. Remove any sources of excessive heat.
8. If it is used in an environment where there is possible contact with oil, weld spatter, etc., exercise preventive measures.
9. When the solenoid valve is mounted in a control panel or it’s energized for a long period of time, make sure the ambient temperature is within the specifications of the valve.
1. Temperature of ambient environment
Use the valve within the range of the ambient temperature specification of each valve. In addition, pay attention when using the valve in environments where the temperature changes drastically.
2. Humidity of ambient environment
• When using the valve in environments with low humidity, take measures to prevent static.
• If the humidity rises, take measures to prevent the adhesion of water droplets on the valve.
Maintenance
1. Perform maintenance and inspection according to the procedures indicated in the operation manual.
If handled improperly, human injury and/or malfunction or damage of machinery and equipment may occur.
2. Removal of equipment, and supply/exhaust of compressed air
Before components are removed, first confirm that measures are in place to prevent workpieces from dropping, run-away equipment, etc. Then, cut off the supply air and electric power, and exhaust all air pressure from the system using the residual pressure release function.
When the equipment is operated after remounting or replacement, first confirm that measures are in place to prevent the lurching of actuators, etc. Then, confirm that the equipment is operating normally.
3. Low-frequency operation
Valves should be operated at least once every 30 days to prevent malfunction. (Use caution regarding the air supply.)
4. Manual override
When a manual override is operated, connected equipment will be actuated.
Operate only after safety is confirmed.
5. If the volume of air leakage increases or the valve does not operate normally, do not use the valve.
Perform periodic maintenance on the valve to confirm the operating condition and check for any air leakage.
1. Drain flushing
Remove drainage from the air filters regularly.
2. Lubrication
In the case of rubber seals, once lubrication has been started, it must be continued.
Use class 1 turbine oil (with no additives), VG32. If other lubricant oil is used, it may cause a malfunction. Please contact SMC for information on the suggested class 2 turbine oil (with additives), VG32.
- 8 -
No.SYJ300-OMV0001
SYJ Series
Specific Product Precautions 1
Be sure to read this before handling the products.
Manual Override Operation
When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.
■Non-locking push type [Standard]
Press in the direction of the arrow
Solenoid Valve for 200, 220 VAC Specifications
Solenoid valves with grommet and L/M type plug connector AC specifications have a built-in rectifier circuit in the pilot section to operate the DC coil.
With 200, 220 VAC specification pilot valves, this built-in rectifier generates heat when energized. The surface may become hot depending on the energized condition; therefore, do not touch the solenoid valves.
■
Push-turn slotted locking type [Type D]
While pressing, turn in the direction of the arrow.
If it is not turned, it can be operated the same way as the non-locking type.
Locked position
When operating the locking type D with a screw driver, turn it gently using a watchmakers screw driver.
[Torque: Less than 0.1 N.m]
■Push-turn locking lever type [Type E]
While pressing, turn in the direction of the arrow.
If it is not turned, it can be operated the same way as the non-locking type.
Common Exhaust Type for Main and Pilot Valve
Pilot air is exhausted through the main valve body rather than directly to atmosphere.
・ Suitable for applications where exhausting the pilot valve to atmosphere would be detrimental to the surrounding working environment.
・ For use in extremely dirty environments where there is the possibility that dust could enter the pilot exhaust and damage the valve.
Ensure that the piping of exhaust air is not too restrictive.
SYJ3000/5000/7000 series
Mixed Installation of 3 Port and 5 Port Valves on Same Manifold.
The SYJ3000/5000/7000 series and the SYJ300/500/700 series can be mounted on the same manifold. How to mount on the same manifold is shown on the following pages.
SYJ300………………………P.17
SYJ500………………………P.19
SYJ700………………………P.21
Locked position
When locking the manual override on the push-turn locking types (D, E), be sure to push it down before turning.
Turning without first pushing it down can cause damage to themanual override and trouble such as air leakage, etc.
- 9 -
No.SYJ300-OMV0001
SYJ Series
Specific Product Precautions 2
Be sure to read this before handling the products.
How to Use Plug Connector
1. Attaching and detaching connectors
・ To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever’s pawl is pushed into the groove and locks.
・ To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out.
2. Crimping of lead wires and sockets
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the ends of the core wires evenly into the sockets, and then crimp with a crimping tool. When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area.
Use an exclusive crimping tool for crimping.
(Contact SMC for special crimping tools.)
Plug Connector Lead Wire Length
Standard length is 300 mm, but the following lengths are also available.
How to Order Connector Assembly
3. Attaching and detaching sockets with lead wires
• Attaching
Insert the sockets into the square holes of the connector (+,
–indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector.
(When they are pushed in, their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires.
• Detaching
To detach a socket from a connector, pull out the lead wire while pressing the socket’s hook with a stick having a thin tip
(approx. 1 mm). If the socket will be used again, first spread the hook outward.
- 10 -
No.SYJ300-OMV0001
SYJ Series
Specific Product Precautions 3
Be sure to read this before handling the products.
Surge Voltage Suppressor DIN Terminal
<For DC>
Grommet, L/M Plug Connector
■ Standard type (with polarity)
Surge voltage suppressor ( S)
With light/surge voltage suppressor ( Z)
■ Non-polar type
With surge voltage suppressor ( R)
With light/surge voltage suppressor ( U)
With surge voltage suppressor (DS)
With light/surge voltage suppressor (DZ)
DIN terminal has no polarity.
M8 Connector
■ Standard type (with polarity)
■ Non-polar type
• Connect the standard type in accordance with the +, – polarity indication. (The non-polar type can be used with the connections made either way.)
• Since voltage specifications other than standard 24 and
12 VDC do not have diodes for polarity protection, be careful not to make errors in the polarity.
• When wiring is done at the factory, positive (+) is red and negative (–) is black.
Solenoid valve side pin wiring diagram
■ With power saving circuit
Power consumption is decreased • For the standard type, connect + to 1 and – to 3 for Type by 1/4 by reducing the wattage required to hold the valve in an energized
W according to polarity, while + to 4 and – to 3 for Type
WA.
• Please be careful not to reverse the polarity, since a state. (Effective energizing time is over 62 ms at 24
VDC.)
Operating Principle
With the above circuit, the current consumption when holding is reduced diode to prevent the reversed current is not provided for
DC voltages other than 24 and 12 VDC.
• The WA-type valve cannot be grounded. to save energy. Please refer to the electric wave data to the right.
• Please be careful not to reverse the polarity, since a diode to prevent the reversed current is not provided for the power saving circuit.
- 11 -
No.SYJ300-OMV0001
SYJ Series
Specific Product Precautions 4
Be sure to read this before handling the products.
Surge Voltage Suppressor
< For AC >
(There is no “S” type because the generation of surge voltage is prevented by a rectifier.)
Grommet, L/M Plug Connector
DIN Terminal
Note) Surge voltage suppressor of varistor has residual voltage corresponding to the protective element and rated voltage; therefore, protect the controller side from the surge. The residual voltage of the diode is approximately 1 V.
DIN Terminal Type Y
A type Y DIN connector is a DIN connector conforming to the
8-mm standard pitch between DIN terminals.
Changing the entry direction
After separating the terminal block and housing, the cord entry can be changed by attaching the housing in the desired direction
(4 directions at 90° intervals).
* When equipped with a light, be careful not to damage the light with the cord’s lead wires.
Precautions
Plug in and pull out the connector vertically without tilting to one side.
Compatible cable
Cord O.D.
: ø3.5 to ø7
( Reference ) 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306
DIN Connector Part No .
< Type D >
Without light
With light
Rated voltage
DC24V
SY100-61-3-05
Voltage symbol
24V
Part no.
SY100-61-3-05
• Since a type D DIN connector has a 9.4-mm pitch between DIN terminals, it is not interchangeable.
• Type D DIN connectors have the “N” indication at the end of rated voltage symbol. (For DIN connectors without lights, “N” is not indicated. Please refer to the name plate to distinguish.)
• Dimensions are the same as type D DIN connector.
• When replacing only the pilot valve assembly, V115 D is interchangeable with V115 Y. Do not replace V111 (G, H, L,
M, W) to V115 Y (DIN terminal), or vice versa.
How to Use DIN Terminal
Connection
1. Loosen the holding screw and pull the connector out of the solenoid valve terminal block.
2. After removing the holding screw, insert a flat head screwdriver, etc. into the notch on the bottom of the terminal block and pry it open, separating the terminal block and the housing.
3. Loosen the terminal screws (slotted screws) on the terminal block, insert the cores of the lead wires into the terminals according to the connection method, and fasten them securely with the terminal screws.
4. Secure the cord by fastening the ground nut.
DC12V
AC100V
AC200V
AC110V
AC220V
< Type Y >
Without light
With light
12V
100V
200V
110V
220V
SY100-82-1
Rated voltage
DC24V
DC12V
AC100V
AC200V
AC110V(AC115V)
Voltage symbol
24VN
12VN
100VN
200VN
110VN
AC220V(AC230V) 220VN
Circuit Diagram with Light
SY100-61-3-06
SY100-61-2-01
SY100-61-2-02
SY100-61-2-03
SY100-61-2-04
Part no.
SY100-82-3-05
SY100-82-3-06
SY100-82-2-01
SY100-82-2-02
SY100-82-2-03
SY100-82-2-04
- 12 -
No.SYJ300-OMV0001
SYJ Series
Specific Product Precautions 5
Be sure to read this before handling the products.
Connector Assembly with Cover
Connector assembly with dust proof protective cover.
• Effective to prevention of short circuit failure due to the entry of foreign matter into the connector.
• Chloroprene rubber for electrical use, which provides outstanding weather resistance and electrical insulation, is used for the cover material. However, do not allow contact with cutting oil, etc.
• Simple and unencumbered appearance by adopting round-shaped cord.
How to Order
SY100-68-A□
Lead wire length
Nil
6
10
15
20
25
300mm
600mm
1000mm
1500mm
2000mm
2500mm
M8 Connector
1. M8 connector types have an IP65 (enclosure) rating, offering protection from dust and water. However please note: these products are not intended for use in water.
Select a SMC connector cable (V100-49-1 ) or a FA sensor type connector, with M8 threaded 3 pin specifications conforming to Nippon Electric Control Equipment Association
Standard, NECA4202 (IEC60947-5-2). Make sure the connector O.D. is 10.5 mm or less when used with the SYJ300 series manifold. If more than 10.5 mm, it cannot be mounted due to the size.
2. Do not use a tool to mount the connector, as this may cause damage. Only tighten by hand. (0.4 to 0.6 N·m)
3. The excessive stress on the cable connector will not be able to satisfy the IP65 rating. Please use caution and do not apply a stress of 30 N or greater.
Failure to meet IP65 performance may result if using alternative connectors than those shown above, or when insufficiently tightened.
30
50
3000mm
5000mm
Connector Assembly with Cover : Dimensions
How to Order
Enter the part number for a plug connector solenoid valve without connector together with the part number for a connector assembly with cover.
〈 Ex1 〉 Lead wire length of 2000mm
SYJ312-5LOZ-M3
SY100-68-A-20
〈 Ex2 〉 Lead wire length of 300mm (standard)
SYJ312-5L P Z-M3
• Connector cable mounting
Note) Connector cable should be mounted in the correct direction. Make sure that the arrow symbol on the connector is facing the triangle symbol on the valve when using SMC connector cable (V100-49-1 ). Be careful not to squeeze it in the wrong direction, as problems such as pin damage may occur.
■
Connector cable
・
Connector cable for M8 can be ordered as follows:
How to Order
1.To order solenoid valve and connector cable at the same time.
(Connector cable will be included in the shipment of the solenoid valve.)
Symbol for connector assembly with cover
※
In this case, the part number for the connector assembly with cover is not required.
Ex. 1) Cable length: 300 mm
SYJ312-5W1ZE-M3
Symbol for electrical entry
- 13 -
No.SYJ300-OMV0001
SYJ Series
Specific Product Precautions 6
Be sure to read this before handling the products.
M8 Connector
1. To order connector cable only
Cable length(L)
300mm
500mm
1000mm
2000mm
5000mm
Part no.
V100-49-1-1
V100-49-1-2
V100-49-1-3
V100-49-1-4
V100-49-1-7
Flat Ribbon Cable Manifold
・ In the manifold valves, the wiring to the individual valves is provided on a printed circuit board, and the connection to the external wires is consolidated through the use of a flat ribbon cable.
・ A single MIL flat ribbon cable connects the entire manifold to your power source. This greatly reduces installation time.
Flat Ribbon Cable Manifold
Manifold Internal Wiring
・ For more than 10 stations, both poles of the common should be wired.
・ For single solenoid, connect to the B side solenoid.
・ The maximum number of stations that can be accommodated is
12. For more stations, contact SMC.
・ Only non-polar valves are available for the DC flat cable manifold, therefore negative COM or positive COM wiring of the manifold is possible. The valve does not switch with negative
COM if a Z type is used. Be sure to use a positive COM.
- 14 -
No.SYJ300-OMV0001
SYJ Series
Specific Product Precautions 7
Be sure to read this before handling the products.
EX510 Gateway-type Serial Transmission System
When ordering the housing only When ordering the connector assembly only
For single solenoids(SY3000-37-81A□ -N)
For double solenoids(SY3000-37-81A□ □ ) Bracket
For bracket attached types of SYJ3000 , do not use it without bracket.
Replacement of Pilot Valve
Connector Assembly Order No. Mount it so that there is no slippage or deformation in gaskets, and tighten with the tightening torque as shown below.
Series
SYJ300
Thread size
Tightening torque
M1.7 0.12N.m
(Can be used for the manifold without a specified layout (8 stations or less))
Model Part no.
SY3000-37-81A-2-N
Connector mounting position
Single : 1 to 4stations
SS5YJ3-
SS5YJ5-
20
SS5YJ7-
,
21
40
21
,
,
,
32
42
41
,
SA
43
SA
SA
SY3000-37-81A-2-5
SY3000-37-81A-1-N
SY3000-37-81A-1-4
SY3000-37-81A-2-N
SY3000-37-81A-2-5
SY3000-37-81A-3-N
SY3000-37-81A-3-6
SY3000-37-81A-3-7
Double/3 position : 1 to 4 stations
Single : 5 to 8 stations
Double/3 position : 5 to 8 stations
Single : 1 to 8stations
Double/3 position : 1 to 8 stations
Single : 1 to 8stations
Double/3 position : 1 to 4 stations
Double/3 position : 5 to 8 stations
SYJ500
SYJ700
M2.5
M3
0.45N.m
0.8N.m
Note) The above is for the station addition or maintenance. When ordering a connector assembly separately, a number would not be printed on the connector.
When ordering connector assembly (except housing)
Connector Assembly Order No.
(Can be used for the manifold with a specified layout)
Model Part no.
Connector mounting position
SS5YJ3-
SS5YJ5-
20
SS5YJ7-
21
,
40
,
21
,
,
32
42
41
,
SA
43
SA
SA
SY3000-37-80A-5
SY3000-37-80A-2
SY3000-37-80A-7
SY3000-37-80A-4
SY3000-37-80A-5
SY3000-37-80A-2
SY3000-37-80A-7
SY3000-37-80A-4
SY3000-37-80A-9
SY3000-37-80A-7
SY3000-37-80A-7
SY3000-37-80A-3
SY3000-37-80A-10
SY3000-37-80A-6
SY3000-37-80A-12
SY3000-37-80A-9
On A side
On B side
On A side
On B side
On A side
On B side
On A side
On B side
On A side
On B side
On A side
On B side
On A side
On B side
On A side
On B side
1 to 8stations
9 to 16stations
1 to 8stations
9 to 12stations
13to16stations
1 to 8stations
9 to 12stations
13to16stations
Note 1) The above is for station addition or maintenance. When ordering a connector assembly separately, a number will not be printed on the connector.
Note 2) After inserting the connector assembly into the housing, be sure to confirm that the lead wire will not come off by lightly pulling the wire. Furthermore, do not reuse the lead wire after it has been inserted and removed.
Note 3) Wiring is set longer than the actual wiring distance.
- 15 -
No.SYJ300-OMV0001
SYJ Series
Specific Product Precautions 8
Be sure to read this before handling the products.
Replacement of Pilot Valve
Pilot valves in this series are improved to provide excellent energy saving results. However following this improvement, these new valves are no longer compatible with the current pilot valve used at the interface. Consult with SMC when you need to exchange these pilot valves, in the case of manual override (marked in orange) of the adapter plate.
- 16 -
No.SYJ300-OMV0001
Construction
SYJ300 series
Component Parts Replacement Parts
No. Description Material Note No. Description
1
2
3
Body
Piston plate
End cover
Zinc die-casted
Resin
Resin
White
White
White
Part no.
6
7
Sub-plate Note1 )
Pilot valve
SYJ300-9-1(-Q)
V111(T)-
□□□
Note) Add suffix “-Q” for the CE-compliant product.
4
5
Piston
Spool valve assembly
Resin
Aluminum ・ HNBR
-
-
Mixed Installation of the SYJ300 and the SYJ3000 Valves on the Same Manifold
The SYJ300 series valves can be mounted on the
Manifolds for SYJ3000 series.
① SS5YJ3-20,SS5YJ3-21P,SS5YJ3-21SA
The 3 port valve can be used by simply sealing off the unused “R” port with rubber plug SYJ3000-33-1.
Applicable solenoid valves :
SYJ312,SYJ312M,SYJ322,SYJ322M series
② SS5YJ3-31,-S31,SS5YJ3-32,-S32,SS5YJ3-32SA
SS5YJ3-46,-S46,SS5YJ3-32P
The 3 port valve can be used without modifica- tion. The A port of the valve will flow out of the B port of the manifold.
Applicable solenoid valves :
SYJ314,SYJ314M,SYJ324,SYJ324M
③ SS5YJ3-41,-S41
The 3 port valve can be used on the 4 port
Manifold by simply sealing off the unused “R” port
With rubber plug SYJ3000-33-1.The A port of the
Valve will flow out of the B port of the manifold.
Applicable solenoid valves :
SYJ314,SYJ314M,SYJ324,SYJ324M
Mounting screw tightening torques
Note
Zinc die-casted
A port of the 3 port valve flows out of the manifold B port.
M1.7 : 0.12N.m
Use caution to the assembly orientation for solenoid valves, gasket ,and optional parts.
- 17 -
No.SYJ300-OMV0001
Combinations of Solenoid Valve, Manifold, Gasket and Manifold Base Blanking Plate Assembly
Body ported(Type SYJ3 □ 2(R)(-Q)) Base mounted(Type SYJ3 □ 4(R)(-Q)) Part no.
: SYJ300-10-7A(-Q)
Note ) Add suffix ”-Q” for the CE-compliant product.
Mounting screw tightening torques
M1.7 : 0.12N.m
Use caution to the assembly orientation for solenoid valves, gasket ,and optional parts.
- 18 -
No.SYJ300-OMV0001
Construction
SYJ500 Series
Component Parts Replacement Parts
No,
1
2
3
4
5
6
Description
Body
Piston plate
End cover
Piston
Spool valve assembly
Spool spring
Material
Aluminum die-cast
Resin
Aluminum die-cast
Resin
-
Stainless steel
Note
White
White
White
-
-
-
No. Description Part no,
7
8
-
Sub-plate
Pilot valve
Note )
Bracket assembly
SYJ500-9-1(-Q)
V111(T)-
□□□
SYJ5000-13-3A
Note) Add suffix”-Q” for the CE-compliant product.
Mix Installation of the SYJ500 and the SYJ5000Valves on the Same Manifold
Use of an adapter plate makes it possible to mount SYJ500 series on the manifold bases of the SYJ5000 series.
When mounting the SYJ500 valve on the SYJ5000 manifold, the SYJ500 solenoid must be positioned on the same side of the manifold as a single solenoid SYJ500.(Refer to the figure below.)
For base mounted type, the A port of the 3 port valve flows out the B port of manifold base.
Note
Aluminum die-cast
Adapter Plate Assembly
< Standard > < CE-compliant >
Mounting screw tightening torques
M2.5 : 0.45N.m
Use caution to the assembly orientation for solenoid valves, gasket ,and optional parts.
- 19 -
No.SYJ300-OMV0001
Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Blanking Plate Assembly
Body ported(Type SYJ5 □ 2(R)(-Q)) Base mounted(Type SYJ5 □ 4(R)(-Q)) Part no.
: SYJ500-10-3A(-Q)
Note ) Add suffix “-Q” for the CE-compliant product.
Mounting screw tightening torques
M2.5 : 0.45N.m
Use caution to the assembly orientation for solenoid valves(blanking plate) and manifold gasket.
- 20 -
No.SYJ300-OMV0001
Construction
SYJ700 Series
Component Parts Replacement Parts
No.
1
2
Description
Body
Piston plate
Material
Aluminum die-casted
Resin
Note
White
White
No.
7
Description
Sub-plate note )
3
4
5
6
End cover
Piston
Spool valve assembly
Spool spring
Aluminum die-casted
Resin
-
Stainless steel
White
-
-
-
Part no.
SYJ700-9-1(-Q)
8
-
Pilot valve
Bracket Ass’y
SYJ700-9-2(-Q)
V111(T)-
□□□
SYJ700-19-1A
Note) Add suffix “-Q” for the CE-compliant product.
Mix Installation of the SYJ700 and the SYJ7000 Valves on the Same Manifold
Use of an adapter plate makes it possible to mount the SYJ700 series on the manifold bases of the
SYJ7000 series.
When mounting the SYJ700 valve on the SYJ7000 manifold, the SYJ700 solenoid must be positioned on the same side of the manifold as a single solenoid SYJ700. (Refer to the figure below.)
For base mounted type, the A port of the 3 port valve flows out the B port of manifold base.
Adapter plate assembly
SYJ700-3-1A(-Q) SYJ700-3-2A(-Q)
SYJ700 Series Body ported SYJ700 Series Base mounted
Mounting screw tightening torques
M3 : 0.8N.m
Use caution to the assembly orientation for solenoid valves, gasket ,and optional parts.
1/8
1/4
Note
Aluminum die-casted
- 21 -
No.SYJ300-OMV0001
Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Blanking Plate Assembly
< Standard >
Body ported (Type SYJ7 □ 2(-Q)) Base mounted (SYJ7 □ 4(-Q) 形 ) Part no.:SYJ700-10-1A
Mounting screw tightening torques
M3 : 0.8N.m
Use caution to the assembly orientation for solenoid valves, gasket ,and optional parts.
<
CE-compliant
>
Part no.:SYJ700-10-2A-1-Q
- 22 -
No.SYJ300-OMV0001
How to Order Pilot Valve Assembly
∗ For type W□, DC voltage is only available.
∗ CE-compliant: For DC only.
∗ For connector cable of M8 connector, refer to page 13 and 14.
Note 1) Enter the cable length symbols in
*Please be sure to fill in the blank referring to page 13 and 14.
Note) Since V111 and V115 are CE-compliant as standard, the suffix "-Q” is not necessary.
- 23 -
No.SYJ300-OMV0001
TROUBLESHOOTING
Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective actio
Trouble phenomenon Cause expected Measures
Faulty operation Pilot valve is not operated Faulty wiring
Blown fuse or disconnection lead wire
Poor contact at contactor wire or connection part
Disconnection coil wire
Foreign matter caught in armature
①
②
③
④
Though pilot valve does shift, but main valve will not shift or will be sluggish.
Leakage
Burnt coil
Air leaks through exhaust port of main valve
Fall of pilot pressure
Swelled out " spool ass'y " ring
Excessive amount of lubricant
Higher voltage or wrong coil used
Coil splashed by water
Abrasion " spool ass'y" ring(in the case of rubber seal)
Poor operation or adherence
Intrusion of foreign matter
Spool has not completely shifted
⑫
⑦
⑧
⑤
⑥
⑨
Poor seal on actuator (cylinders, etc.) side
Foreign matter caught in air seat of pilot valve
Foreign matter caught in core of pilot valve
⑤
⑥
⑩
④
Air leaks through gasket Insufficient bolt tightening ⑪
- 24 -
No.SYJ300-OMV0001
Remedy
No.
①
②
③
④
⑤
Remedy
Re-wire correctly.
Replace part.
Replace part or re-wire positively.
Replace valve.
Regulate pressure so that pilot pressure will fall within operating pressure range furing operation.
・ If wrong oil is used, completely air blow to remove oil, and replace valve. After valve is replaced, use turbine oil class 1 (ISO VG32).
⑥
・ When a large quantity of drain is given and cannot carry out drain omission surely, install either an auto-drain or a dryer.The valve should be replaced.
⑦ Check voltage. Replace valve (pilot valve).
⑧ Protect the valve so that water does not splash the coil. Replace valve (pilot valve).
⑨
⑩
In case of intrusion of foreign matter, to remove foreign matter by air blow of piping and then replace valve.
Repair or replace actuators.
⑪ After stopping air and re-tighten the bolts.
⑫ Reduce the amount of lubricant to the degree that no oil splashes out of the air exhaust (E) port.
If no improvement is achieved in spite of the above countermeasure, inside of the valve may have some abnomality. In this case, stop using the valve immediately.
If any of followings are carried out, inside of the valve may have some failure. In this case, stop using the valve immediately.
① Voltage out of rated voltage has been used.
② Oil other than the specified one has been lubricated.
③ Lubrication has been stopped intermediately, or lubrication was suspended temporary.
④ Water splashed directely.
⑤ Strong impact was given.
⑥ Alien substance such as drain and particle got into. Drain or garbage invaded a valve.
⑦ Prohibited way of using the valve which is written at "Precautions" section in this operation manual
was carried out excluding above-mentioned.
In addition, in the case of trouble, please send it back to the supplier for repair or replacement.
- 25 -
No.SYJ300-OMV0001
S
Revision history
1st Printing :Wo
4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN
Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362
URL http://www.smcworld.com
Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
© 2017 SMC Corporation All Rights Reserved
No.SYJ300-OMV0001