Imani

7” IP video intercom with touch screen

Thank you for choosing our equipment

User manual

1

Attention

!

!

As a result of continuous upgrades and functionality improvements, technical characteristics of the device can be changed without any preliminary declaration.

This manual can contain some inaccuracy or misprint. The owner reserves the right to make corrections to the information described in the user manual and device package.

The last revision of this manual is available on www.slinex.com

Safety instructions

Please read and keep that manual.

The device installation process should be carried out by the qualified specialists.

Use the device from the –40 ˚C to +50 ˚C (–40 ˚F to 122 ˚F), always keep it within that temperature range.

Installation surface should be free from vibration and impact influence.

Keep this device far from open sources of heat, such as radiators, heaters, and ovens.

The device can be installed near other electronic equipment in case if the temperature of the environment does not exceed previously mentioned range.

The device should be protected from the direct influence of the natural phenomena, such as direct sunlight, rain or snow.

Don’t use aggressive or abradant detergent for the device surface cleaning.

Use soft wet cloth or tissues to remove strong dirt.

Nature protection

Don’t throw away the device with other industrial or nutritive trash if you see that symbol. Some regions have separation and recycling systems for the electronic equipment. Connect with local authorities to receive information about recycling of electronic equipment for your region.

Rights and limitation of liability

All rights reserved. Any part of that document can not be published in any form, translated into other languages or reproduced in any way including electronic or mechanical.

Document recording and copying are strictly forbidden without owner permission.

Imani

Table of contents

1. Package ...................................................................................................................................................................................... 3

2. Specification ............................................................................................................................................................................. 3

3. Description................................................................................................................................................................................ 4

4. Installation................................................................................................................................................................................. 5

4.1 Schematic diagrams................................................................................................................................................ 5

4.2 Unit mount ................................................................................................................................................................. 7

5. Software setup......................................................................................................................................................................... 8

5.1. Security....................................................................................................................................................................... 8

5.2. Intercom ..................................................................................................................................................................... 12

5.3. Message...................................................................................................................................................................... 14

5.4. Setup............................................................................................................................................................................ 14

6. Web interface ........................................................................................................................................................................... 17

6.1. «Main» bookmark.................................................................................................................................................... 17

6.2. «Network» bookmark ............................................................................................................................................ 17

6.3. «Address» bookmark.............................................................................................................................................. 18

6.4. «SIP Settings» bookmark ...................................................................................................................................... 18

6.5. «Others» bookmark ................................................................................................................................................ 19

6.6. «Logout» bookmark ............................................................................................................................................... 19

7. Limited warranty..................................................................................................................................................................... 20

REV. 1.0

2

1. Package

Imani IP video intercom – 1 pc.

Surface mount bracket– 1pc.

Connection wires kit – 1 pkg.

Mounting screws – 1 pkg.

User manual – 1 pc.

2. Specification

205 mm (8.07")

20 mm (0.79")

3

SCREEN

7”, color TFT with touch screen, 800×480 px.

HARDWARE

1.2GHz, ARM Cortex-A7,

64MB DDR2 SDRAM

128MB NAND FLASH

OPERATION SYSTEM

Linux

NETWORK

Ethernet(10/100Base-T) RJ-45

IP CAMERA SUPPORT

8 cameras

26 mm (1.02")

POWER

DC 12 V or PoE (802.3af standard)

STANDBY MODE POWER CONSUMPTION

1.5 W

WORKING MODE POWER CONSUMPTION

5 W

MOUNTING TYPE

Surface mount

DIMENSIONS

205×129×26 mm (8.07×5.07×1.02")

WORKING TEMPERATURE

–10 ... +55 ˚C (+14...+131 ˚F)

Imani

3. Description

1

2

Wire connectors pinout

Power supply

GND

+12V

RS 485 interface

+12V

GND

485+

485-

Siren/

Alarm inputs

V+

GND

AL1

AL2

AL3

3

4

1

2

Display with touch screen

Microphone

Speaker

Ethernet connector RJ-45

AL4

AL5

AL6

AL7

AL8

Alarm inputs

4

3

4

Diagram 2. Basic network connection

Imani indoor monitor Tabo outdoor station

Imani

4. Installation

4.1 Schematic diagrams

Diagram 1. Alarm sensors and siren connection

Power supply

12V, 2A

+12V GND

5

V+ GND AL1 AL2 AL3 AL4 AL5 AL6 AL7 AL8

Siren

GND +12V

2.2 kOm

NO sensor

Normlly-opened sensor connection

2.2 kOm

NC sensor

Normlly-closed sensor connection

Power supply

12V, 2A

+12V GND

Router with PoE

WAN 1 2 3 4

Internet connection

CAT5 twisted pair cable

CAT5 twisted pair cable with PoE

Note:

Imani monitor can be powered by 12V power supply or by PoE (802.3af) through LAN connector.

Total network cable length between devices must not exceed 80 meters for PoE connection (red) and 100 meters for ordinary connection (without PoE).

6

4.2 Unit mount

1) Take a bracket from the kit and place it 150-160 cm (4.9-5.2 ft.) from the floor line.

2) Mark and drill four halls and prepare space in the wall that should be used for wires setup.

3) Take four wall anchors from the kit and hammer them into the drilled halls.

4) Fix the bracket on the wall by the screws from the kit.

6) Connect all communication wires and fix the outdoor station on the mounting bracket.

7

5. Software setup

Below you can see monitor main screen:

14:37

Security Intercom Message Setup

There four main menues here:

Security – alarm settings;

Intercom – call other monitors, view image from outdoor panels and records playback;

Message – view messages history;

Setup – monitor settings.

5.1. Security

Security

ON/OFF Camera

Zone Scene Setup

Imani

8

This menu contains alarm setup options, such as sensors type, delays, sensors schedule, scenarios, etc.

ON/OFF: alarm scenarios activation, four options are available, active scenario highlighted by the circle;

Out – enable this scenario when you are out of home;

Home – enable this scenario when you are at home;

Sleep – enable this scenario in a night time;

OFF – disable alarm functions.

Default alarm password is: 1234

Security

Out Home Sleep OFF

ON/OFF

Camera: IP cameras monitoring, press or button to select camera for monitoring then press to start monitoring. Press button to stop monitoring.

Security

9

Camera

Imani

For adding and deleting IP cameras from the list refer to devece web interface settings (page).

Zone: alarm zones setup defines types of sensors and working delays for each zone. Default password for entering zone setup is: 1234. Zones setup can only be performed if alarm is off;

NO. – zone input number;

Type – «Normal» enables current zone only in armed mode, «Emergency» or «24 Hour» makes current zone always active;

Mode – input trigerring type «3C», «NO», «NC» or «BELL» options are available;

Delay – delay before alarm activation in seconds, can be set as 0s, 5s, 15s, 20s, 25s, 40s, 60s;

Sensor – sensor type is used for information purpose while alarming, «Smoke», «Gas», «Pir», «Door»,

«Window», «Panic» or «Flood» options are available;

Security

Zone

NO. Type

1

2

24 Hour

24 Hour

3 Normal

4 Normal

5 Emerg.

6

7

8

24 Hour

24 Hour

24 Hour

Mode

3C

NO

NO

NC

3C

BELL

NO

3C

Delay

0s

0s

15s

60s

0s

0s

0s

0s

OK

Sensor

Smoke

Gas

Window

Door

Panic

Panic

Flood

PIR

10

Imani

Scene: alarm scene setup defines which number of sensors must be monitored in every scenario. Default password for entering scene setup is: 1234.

sign means that currrent zone is enabled for corresponding scenario.

Activation time is the time alarming is in progress, can be set as None, 30s, 40s, 60s, 100s or 300s.

Security

Activation Time: 30s

Mode 1 2 3 4 5 6 7 8

Out

Home

Sleep

Scene

OK

Setup: Here you can change alarm function password. Default password is: 1234. Enter old password then enter new one and then confirm a new password and press «OK» button to apply it.

Password

Old:

New:

Confirm:

Security

Setup

OK

11

5.2. Intercom

Intercom

Call Out Monitor Records

Call Out: input 1-3 digit building number + «Building» button + 2 digit unit number + «Unit» button + 4 digit room number, then press to start call.

Press «Center» button to call management center, the system will call management center from1 to 5. If the management center can not be reached or the call failed, the system calls next management center.

Device

Device 02

Intercom

Call Out

1 2 3

4 5 6

7 8 9

0 C

Building

Unit

Center

12

5.3. Message

Message

NO. Сontent

1

2

3

4

Announcements

Today’s top headlines

News service

Visual reporting

Date

19-8-14 8:26:30

19-8-14 11:35:44

19-8-18 10:17:57

19-8-19 13:22:01

Imani

Monitor: press icon to switch outdoor panel and flat camera mode. Press or icon to switch video inputs then press icon to start monitoring. Press icon to stop monitoring or press icon to open lock.

Intercom

Call Out Monitor Records

Door 1

Monitor

Records: first column icon indicates type of the call: – outgoing call icon, – incoming call icon,

– missed call icon. Use and icons to switch between the records, press icon to call current record or press icon to delete it. Also you can view snapshot by pressing icon if it is taken during the call.

Intercom

NO. Number

1

2

3

4

5

6

10001

10001010017

1019901

10001010017

10001010017

1019901

Date Length

19-8-14 8:26:30

19-8-14 11:35:44

19-8-15 13:22:57

19-8-16 6:55:01

19-8-16 12:44:44

19-8-16 14:31:15

3s

4s

1s

11s

5s

15s

Records

13

Use and icons to switch pages up and down. Press icon to delete current record.

Message box can handle up to 64 messages.

Note:

Imani indoor monitor can only receive meassges from PC if management software on guard station is installed.

5.4. Setup

Normal

Room

Network

Password

Version

Volume:

Intercom:

Language: English

TimeZone: +08:00

Auto answer:

Setup

OK

14

Normal: general indoor monitor settings;

Volume – monitor speaker voulume;

Intercom – talking volume;

Language – interface language;

TimeZone – current geo position time zone;

Auto answer – enable/disable automatic answering function.

Setup

Normal

Room

Network

Password

Version

Building: 1

Unit: 1

Room: 17

Device: 0

Sync: 123456

Room

OK

Room: monitor logical address settings (default password: 123456);

Building – building number (2 figures);

Unit – unit number (2 figures);

Room – room (apartment) number (4 figures);

Device – if there are several monitors then use different device number for each device (0-8);

Sync – synchronization password must be the same for all devices with the same room number.

Setup

Normal

Room

Network

Password

Version

IP address: 192.168.1.253

Net Mask: 255.255.255.0

Gateway: 192.168.1.1

DNS Serv: 8.8.8.8

Server: 192.168.68.1

15

Network

OK

Imani

Network: monitor logical address settings (default password: 123456);

IP address – device IP address;

Net Mask – device subnet mask;

Gateway – network gateway;

DNS Serv – DNS serever IP address;

Server – server IP address.

Setup

Normal

Room

Network

Password

Version

Old:

New:

Confirm:

Password

OK

Password: Here you can change administrator password. Default password is: 123456. Enter old password then enter new one and then confirm a new password and press «OK» button to apply it.

Setup

Normal

Room

Network

Password

Version

Firmware: 1.5.4 20180620

UI version: 1.0.0 20180517

IP address: 192.168.1.253

MAC: BC:F8:11:04:94:72

Version

Version: Here you can find system firmware version, current monitor IP and MAC addresses.

16

6. Web interface

Enter indoor monitor IP adress into PC’s browser address line to enter web interface. Note that your PC must be in the same segment of local network.

Enter to the web interface using next parameters (by default):

Login: admin

Password: 123456

Then press “SIGN IN” button.

6.1. «Main» bookmark

Below you can see web interface main screen:

Imani

6.3. «Address» bookmark

Press «Address» bookmark on the left side of the screen to enter monitor logical address settings:

Build – building number (2 figures);

Unit – unit number (2 figures);

Floor – floor number (2 figures);

Room – room number (2 figures);

Device – if there are several indoor monitors then use different device numbers for each device (0-8);

Sync – synchronization password must be the same for all devices with the same room number.

Server – management server IP address;

Password – management server password.

Here you can find current door station firmware version and SIP status.

6.2. «Network» bookmark

Press «Network» bookmark on the left side of the screen to enter monitor network settings:

DHCP – disable to enter IP address manually or enable to receive IP address automatically from network device (like router);

IP – device IP address;

Mask – device subnet mask;

6.4. «SIP Settings» bookmark

Press «IP Settings» bookmark on the left side of the screen to enter monitor SIP settings:

Enable/Disable – enable/disable SIP function;

Proxy – proxy server name (default value – sip:pbx.slinex.com );

Realm – authentication host (default value – pbx.slinex.com);

User – SIP account user name;

Password – SIP account password;

H.264 – H.264 profile (default value – 102);

STUN IP – STUN server name (default value – stun.I.google.com);

STUN port – STUN port number (default value – 19302);

Timeout – SIP call timeout in seconds.

17 18

6.4. «Others» bookmark

Press «Others» bookmark on the left side of the screen to enter monitor other settings:

Reboot – press to restart indoor monitor.

6.5. «Logout» bookmark

Press «Logout» bookmark on the left side of the screen to enter logout menu:

Submit – press to logout from indoor monitor web interface.

19

Imani

7. Limited warranty

Manufacturer guarantees product normal functioning during the warranty period if the user keeps all safety instructions described in that manual.

Warranty period is 12 months from the moment of the product purchasing (warranty period could be extended up to 24 months or more, depending on the local regulations).

Warranty period allows user to make guarantee repair in cases when normal functioning of the product was violated by the fault of manufacturer and the user haven’t offend transporting, installation and working conditions.

This limited warranty does not cover any damage to the product that results from improper installation, accident, abuse, misuse, natural disaster, insufficient or excessive electrical supply, abnormal mechanical or environmental conditions, or any unauthorized disassembly, repair or modification.

Warranty void in such cases:

• the product was damaged by the fault of the customer;

• the product wasn’t properly installed according reccomendations from the manual;

• the sticker on the backside of the product was broken;

• the product was not used for its intended function.

This limited warranty covers only repair, replacement, refund or credit for defective products, as provided above. Manufacturer is not liable for, and does not cover under warranty, any damages or losses of any kind whatsoever resulting from loss of, damage to, or corruption of, content or data or any costs associated with determining the source of system problems or removing, servicing or installing products.

This warranty excludes third party software, connected equipment or stored data. Manufacturer is therefore not liable for any losses or damage attributable to third party software, connected equipment or stored data.

In the event a product has been discontinued, manufacturer shall either repair the product, offer to replace it with a comparable product or provide a refund at the lesser of the purchase price or the product’s current value.

Repaired or replacement products will continue to be covered by this limited warranty for the remainder of the original warranty term.

20

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Questions and Answers

What is the maximum distance between the Imani monitor and the outdoor station?
The maximum distance is 80 meters for PoE connection and 100 meters for ordinary connection.
How many IP cameras can the Imani monitor support?
The Imani monitor can support up to 8 IP cameras.
What is the default alarm password?
The default alarm password is 1234.
How many alarm scenarios are available?
There are four alarm scenarios available: Out, Home, Sleep, and OFF.
What types of sensors can be connected to the Imani monitor?
The Imani monitor supports various types of sensors, including smoke, gas, PIR, door, window, panic, and flood sensors.

Related manuals