Frico 85 701 60, ICSR20 Manual

Add to My manuals
14 Pages

advertisement

Frico 85 701 60, ICSR20 Manual | Manualzz

ICSR

SE .

... 6

NL .

... 46

GB .

... 14

ES .

... 54

NO .

... 22

IT .

... 62

DE .

... 30

PL .

... 70

FR .

...38

ICSR

A

ICSR

Type

ICSR20

ICSR30

A

854

1070

238

2

Accessories

ICSR

ICPP20

ICPB

ICAP

ICUB

ICAB

Type

ICPP20

ICPB

ICAP15

ICAP20

ICUB

ICAB

E-nr [SE]

85 701 55

85 701 56

85 701 57

85 701 58

EL-nr [NO]

L: 2 m

L: 1,5 m

L: 2 m

3

Wiring diagrams

ICSR

ICSR

4

ICSR

Technical specifications | Carboninfra ICSR with directed heat distribution, remote, installation height 1,8 – 3,5 m 3

Type

ICSR20

ICSR30

E-nr (SE)

85 701 59

85 701 60

EL-nr (NO) Heat output

[W]

2000

3000

Voltage

[V]

230V~

230V~

Amperage

[A]

8,7

13

Max. filament temperature

[°C]

1200 +/-100

1200 +/-100

Weight

[kg]

6,2

7,1

Protection class IC, horizontal position: (IP44), splash-proof design.

CE compliant.

5

GB ICSR

Assembly and operating instructions

General Instructions

Read these instructions carefully before installation and use. Keep this manual for future reference.

The product may only be used as set out in the assembly and operating instructions. The guarantee is only valid if the product is used in the manner intended and in accordance with the instructions.

Application

Carboninfra IC provides a smooth and direct heat that fits well on terraces and balconies.

IC is also ideal for spot heating, both indoors and in more protected areas outdoors. The heat lamps in the IC have a very long service life, the operating time is up to 10 000 h.

ICSR has a focused heat spread and is intended for higher installation height. ICSR can be controlled using a remote control or the control panel on the heater.

All models can be installed vertically as well as horizontally and have an integrated output selector and thermostat.

Protection class, horizontal position: IP44

14

Control

Remote control

LED Red

L1

Red

L2

Red

L3

ICSR

Yellow

L4

Yellow

L5

Display Green

L6

GB

LED

Red L1

Red L2

Red L3

Red L2 + red L3

Yellow L4

Red L5

Green L6 Indication

Blinking

Description

Standby

Lower heating element ON

Upper heating element ON

Both elements ON

Timer active

Temperature in °C

Automatic mode

Manual mode

2

3

4

5

Remote control

1

Description

Decrease temperature and time

Increase temperature and time

Choose timer mode

Choose manual or automatic mode

On/off

Battery (AAA) 1,5V x 2

Open lid

15

GB ICSR

Start up

1. Connect the plug (standby mode).

The heater can be controlled using the remote control or the control panel on the heater.

2. Push the O/I- to activate the heater.

Manual mode

In manual mode the electronic thermostat is not used. Select manually if upper element, lower element or both elements should be switched on.

The prevailing temperature is shown in the display (room temperature).

To switch on the heater the elements must be activated by the output selector or a setpoint must be registered.

Timer

The timer allows the desired operating time

0-20 hours to be set.

1. Push TIMER.

2. Select desired time with + and –.

LED L4 is lit when the timer is active.

SET

Activate manual or automatic mode.

When LED L6 is lit the heater is in automatic mode. To switch to manual mode, push SET repeatedly until L6 starts to blink. To choose the heating power, push SET repeatedly in manual mode (upper element element ON, lower element ON, both elements ON).

To choose automatic mode push the SETbutton when both elements are ON in manual mode.

Constituent parts

Automatic mode

When the heater is on and in automatic mode, press the + or - to set the desired set point.

When the room temperature (actual value) is less than 1 °C below the set point both elements are on. When the actual value is

1 °C below the set point one element switches off, when the actual value is equal to the set point both elements switch off.

When the actual value falls below 1 °C the set point two elements switch on.

Example:

• Set point: 22 °C, Room temperature

(actual value): 15 °C => Both elements

ON.

• The room temperature increases to 21 °C

=> one element OFF.

• The room temperature increases to 22 °C

=> both elements OFF.

• The room temperature decreases to below

21 °C => both elements ON.

ICSR

Bracket

Temperature setting: +10 – +40 °C (+/- 1 °C).

Reflector

Spot angle

50°

Double

IR-carbonelement

Medium wave

Ventilating body

Front grid metal

Universal holder

Horizontal or vertical mounting

Radiant angle

30° – 0° – 30°

Connection box

16

ICSR

Bracket

Rotating to horizontal or vertical position on wall or stand

Rip for horizontal position

Rip for vertical position

GB

Rotating from horizontal to vertical position, 90°.

Note: Only clockwise.

The heater must be off and the plug pulled from the socket. When rotating the heater, the metal body should be carefully touched by hand.

Rotating from vertical to horizontal position, 90°.

Note: Only anticlockwise.

17

GB

Mounting

Wall or ceiling mounting with the bracket

74 mm

ICSR

ø8 mm

Screw DIN 7505 D 5 x 60

Plug D 8 PE 8 x 40

Wall or ceiling mounting with the bracket and aluminium profile ICAP

Max

250 mm

After assembly and after the radiation angle is set, tighten the screws.

Screw DIN 7505 D 5 x 60

Plug max 250 mm D 8 PE 8 x 40

Mounting of bracket on post ICPP with stand foot ICPB

After assembly and after the radiation angle is set, tighten the screws.

Note: Please observe minimum mounting distance in the manual.

18

Electric installation

Cable and plug

Cover must be used.

ICSR GB

Fixed installation

ICSR20: 3x1,0 mm 2

ICSR30: 3x1,5 mm 2

Should only be replaced by a qualified electrician.

The installation, which should be preceded by an omnipolar switch with a contact separation of at least 3 mm, should only be wired by a competent electrician and in accordance with the latest edition of IEE wiring regulations.

Cable holder

Terminal block

Cover must be used.

A Built-in

B On surface

19

GB

Minimum mounting distance

Wall mounting

ICSR20: min 30 cm,

ICSR30: min 50 cm

Min

40 cm

ICSR

Adjustable radiant angle

Min 10 cm

Min

50 cm

Ceiling mounting

Min 1,8 m from floor

Horizontal mounting min 1,8 m

Vertical mounting

Min

40 cm

Min

50 cm

Adjustable radiant angle

Mounting on stand

Min 2,2 m from floor

Possible to turn vertically

Radiant angle

30°

Min 1,5 m to textiles and furniture.

Min 1,8 m from floor

20

Maintenance

Note! When using for the first time or when starting up after a long period of disuse, a small amount of smoke and a slight odour may occur temporarily, which is completely normal.

The power supply to the unit must be disconnected during all service, repair and maintenance work.

The unit has no moving parts so the maintenance requirement is small, but it must be kept clean and free from dust and dirt. If the reflector is not clean the thermal radiation from the unit will decrease and the heater will become hotter. A large amount of dirt can cause overheating.

The surface of the reflector is sensitive and must be cleaned with care. If the reflector is dirty it must be cleaned or replaced by a specialist.

ICSR GB

Safety

• During operation the surfaces of the unit are hot!

• The unit must not be fully or partially covered with inflammable materials, as overheating can result in a fire risk!

• This product is not designed to be used by children or persons with reduced physical or mental ability or a lack of experience and knowledge, unless instruction regarding the product's use has been given by a person with responsibility for their safety or that this person supervises operation. Children must be kept under supervision to ensure they do not play with the product.

• The heater is equipped with a protective grille to prevent contact or to prevent large objects from touching the hot lamp.

The unit must not be used without this protective grille.

• Ensure that there are no inflammable materials gathered on or close to the heater.

• The free space to the inflammable material in the direction of radiation must be at least 1,5 meter.

• Do not place the heater directly under the electrical socket.

• The cable and plug must not be exposed to the heat from this appliance.

• Do not use timer that switches the heater on automatically since a fire risk exists if the heater is covered or positioned incorrectly.

Assembly and disassembly of the front grid

21

Main offi ce

Frico AB

Box 102

SE-433 22 Partille

Sweden

Tel: +46 31 336 86 00

Fax: +46 31 26 28 25 [email protected]

www.frico.se

For latest updated information and information about your local contact: www.frico.se