Cino FuzzyScan F600BT Series, Fuzzyscan, HB2110 Reference Manual
Advertisement
Advertisement
WIRELESS IMAGER
Reference Manual
International Edition, Rev. A
5
Appendix
Revision History
Rev. No.
Rev.A
Rev.A1
Rev.A2
Rev.A3
Rev.A4
Rev.A5
Released Date Description
Oct. 16, 2009 First Release
Oct. 22, 2009 Page 6 Revise “Clone” function operation method.
Page 68 Add “Save Configuration” and “Master Default” quick set commands.
Nov. 27, 2009 Page 53 Bluetooth Device Name – Modify user define characters from 1 – 14 characters to
1 – 16 characters.
Page 69 Add scanner and cradle indications.
Mar. 05, 2010 Page 25 Modify UPC-E/EAN-8 expansion and UPC-A standardization.
Page 43 Rename “Time Out Control” to “ Serial Response Time-out ”.
Page 45 Rename “Presentation Scanning Mode” to “ Presentation Control ”.
Page 48 Rename “Auto Power Off Duration” to “ Light Source On Time ”.
Add “Extremely short” option to Good Read Duration.
Page 49 Rename “Presentation Scanning Auto-sense” to “ Presentation Auto-sense ”.
Add “Presentation Sensitivity”
Apr. 27, 2010 Page 38 Hands Free Time out – Add “ Disable ”.
Page 43 Baud Rate – Add 57.6K BPS and 115.2K BPS.
June 28, 2010 Page 27 Add “UPC/EAN Security Level”.
Page 49 Add “Time Delay to Low Power Trigger”
© Copyright Cino Group
© Copyright PC Worth Int’l Co., Ltd
Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied, reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written permission of Cino. All product information and specifications shown in this document may be changed without prior notice.
Warranty
Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino’s control, such as, but not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA procedures to return Cino for inspection.
Regulatory
FCC part 15B, FCC part 15C
EN55022, EN55024, EN60950-1, EN301 489-1 & 489-17, EN300 328
CNS13438, CNS14336
LP0002
MIC T401
LED Eye Safety IEC60825-1, EN60825-1
Table of Contents
Getting Started
Getting Familiar with Your FuzzyScan
Preparation before Using
Decide Your Radio Link Mode
Using FuzzyScan in PAIR Mode
Using FuzzyScan in PICO Mode
Using FuzzyScan in HID Mode
Using FuzzyScan in SPP Mode
Out-of-range Scanning/Presentation Scanning/Paging Function
Batch Scanning (Inventory Mode)
Configure Your FuzzyScan
Bar Code Programming Manual
Programming Procedures
Host Interface Selection
Symbology Reading Control
Keyboard Interface Control
Serial Interface Control
Wand/Laser Emulation Control
Operation Control
Condensed DataWizard
Appendix
Symbology ID Table
Keyboard Function Code Table
ASCII Input Shortcut
Link Mode Quick Set/Operation Mode Quick Set
Host Interface Quick Set
Option Codes
System Commands
Indications
13
14
18
19
38
42
45
46
56
5
7
8
10
11
1
2
3
4
67
68
69
70
63
64
65
66
Getting Started
Getting Familiar with Your FuzzyScan
Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination of cutting-edge
FuzzyScan 2.0 Imaging Technology and Bluetooth 2.1 EDR wireless technology, it not only provides outstanding reading performance, but also delivers the convenience and freedom of mobility. This document provides a quick reference for installation and operation purposes. The complete documentation is available at www.cino.com.tw
.
F700BT Series Scanner HB2110 Smart Cradle (Base)
Center Indicator
Side Indicators
Paging/Reset Button
Host Interface Port
DC Power Jack
F600BT Series Scanner
Link Indicator
Status Indicator
Beeper
Scan Window
Trigger
Reset Button
Battery Cavity
End Cap
HB2100 Charging Cradle (Base)
Power Indicator
Reserved
Reserved
DC Power Jack
1
Getting Started
Preparation before Using
Install the Battery
Charging the Battery
Ensure the battery contacts of the battery pack are facing the charging contacts inside the battery cavity.
Slide the battery pack into the battery cavity until hearing a click sound before locking it with the end cap. The scanner will give 4 beeps when the battery pack is installed properly if the battery pack still has power.
Secure the end cap with the screw provided, and make sure the end cap is secured properly before using the scanner.
There are 4 different power plugs in your power supply kit. Choose the appropriate local plug and slot it onto the power adapter cavity until it is locked.
Plug the AC power plug into the appropriate AC wall socket.
Plug the DC power cord of the power supply unit into the DC power jack of the cradle.
The smart cradle will issue the power on beeps and the center indicator will give one blue blink . If you use the charging cradle, please check the power indicator of the charging cradle turns steady blue .
Place the scanner on the cradle. The status indicator of scanner will turn steady red if the battery is not fully charged. When the battery is fully charged, the status indicator of scanner will flash green at regular interval.
Please charge the new battery pack for 8 hours prior to the first use.
2
Getting Started
Decide Your Radio Link Mode
The FuzzyScan Bluetooth image scanner provides several radio link modes to communicate with most host devices. When the Bluetooth-enabled host device is not available, it can work with the smart cradle in PAIR mode (one to one connection) or
PICO mode (multiple connections) to provide a plug-and-play cordless migration of your existing non-Bluetooth-enabled IT assets. Moreover, you are also able to use the scanner to work with Bluetooth-enabled host devices via SPP master/slave modes and HID mode.
After losing the radio link, the scanner is capable of resuming the radio connection automatically while it returns to the communication coverage. But please note that this feature is not available in SPP slave mode. If you would like to change the radio link mode, you have to scan the “Uninstall” command to revert the scanner to uninstall state.
PAIR Mode
If the Bluetooth device is not available in your existing system, this is the simplest plug-and-play solution. In this mode, one scanner can only work with one smart cradle. The smart cradle not only provides the Bluetooth radio link with the scanner, but also offers the legacy cabled interfaces to the host device, including USB HID, USB COM, PS/2(DOS/V) Keyboard
Wedge and RS232 Serial.
PICO Mode
For the requirement of multiple connections, up to 7 scanners can be connected to one smart cradle concurrently. If you would like to un-pair all paired scanners and smart cradle, you can simply press and hold the paging/reset button of the smart cradle for over 3 seconds. If you just want to un-pair part of the paired scanners, please take those paired scanners to scan the “Uninstall” command one by one.
HID Mode
Through the most helpful HID service, the scanner can work like a Bluetooth keyboard. In this mode, the scanner is discoverable by the radio connection request issued by a remote host device. For security purpose, you will be requested to input the PIN Code to establish the Bluetooth connection in most time.
SPP Master/Slave Mode
Through the standard SPP service, the scanner can work like a serial input device. In SPP master mode, the scanner initiates the radio connection request to a remote slave device. In SPP slave mode, the scanner is discoverable by the radio connection request issued by a remote master device.
3
Getting Started
Using FuzzyScan in PAIR Mode
Ensure the battery is fully charged. You may refer to the section of Preparations before Using for details.
Please choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device.
USB PS/2
Turn on the power of your host device.
RS232
Please note that the scanner has been pre-paired already, if the scanner is shipped together with the smart cradle. You will see the link indicator of scanner gives 1 blue blink per 2.5 seconds and the middle indicator of smart cradle turns steady blue. If the scanner and smart cradle just give alternating red and green blinks (in “ Uninstall ” state), please follow steps 5-6 to establish the connection between the scanner and the smart cradle.
Scan “PAIR mode” command. The status indicator of scanner will turn steady red.
Uninstall PAIR Mode
Place the scanner on the smart cradle, then you will hear one short beep to indicate the pairing process is activated. The scanner will give continuous short clicks and the link indicator of scanner will flash blue quickly during the pairing process.
When you hear 4 beeps in ascending tone, the pairing process is completed. You will see the link indicator of scanner giving 1 blue blink per 2.5 seconds and the center indicator of the smart cradle turning steady blue .
If the scanner pairing process failed or it’s not placed on the smart cradle within 20 seconds, you will hear 2 “Di-do Di-do” beeps to indicate pair failure, the scanner will return to uninstall state automatically.
Scan the corresponding host interface quick set command to complete the installation.
The default host interface of smart cradle is preset to USB HID. If you want to set the host interface to USB COM, you have to install the USB virtual COM driver into your host device before using the scanner. Please visit the CINO website to download the software driver.
4
Getting Started
Using FuzzyScan in PICO Mode
Ensure the battery is fully charged and choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device.
USB PS/2
Turn on the power of your host device.
RS232
Ensure the side indicators of the smart cradle give alternative red and green blinks (in “ Uninstall ” state). If the smart cradle is paired with other scanners, you can press and hold the paging/reset button for over 3 seconds to un-pair all paired scanners. Then the smart cradle will return to uninstall state automatically.
Prepare the scanners you desire to pair with smart cradle. Ensure the status indicator of each scanner give alternative red and green blinks (in “ Uninstall ” state). If the scanner is not in uninstall state, please scan the “Uninstall” command to un-pair the scanner. Then scan the “PICO mode” command, and the status indicator of scanner will turn steady red.
Uninstall PICO Mode
Place the scanner on the smart cradle, then you will hear one short beep to indicate the pairing process is activated. The scanner will give continuous short clicks and the link indicator of scanner will flash blue quickly during the pairing process.
When you hear 4 beeps in ascending tone, the pairing process is completed. You will see the link indicator of scanner giving 1 blue blink per 2.5 seconds , the center indicator of the smart cradle turning steady blue and its side indicators turning steady green .
If the scanner pairing process failed or it’s not placed on the smart cradle within 20 seconds, you will hear 2 “Di-do Di-do” beeps to indicate pair failure, the scanner will return to uninstall state automatically.
Scan the corresponding host interface quick set command to complete the installation.
Please follow the same procedures to pair the other scanners with the smart cradle.
For user’s convenience, the smart cradle will automatically assign the ID numbers to each scanner. After completed all pairing processes, you can scan the “System Information” command to check the assigned ID number of each scanner.
5
Getting Started
Clone Function
For the user’s convenience, the clone function will help you to clone the host interface related parameters (please refer to following table for details) from one of the paired scanners to the rest of paired scanners under PICO mode. You can use one of the paired scanners to set the host interface related parameters first and then scan “Save Configuration” command.
After that, please take the other paired scanners to scan “Clone” command one by one to clone the host interface related parameters.
Please ensure to keep those paired scanners in connected status when you use the “Clone” function. Because the host interface related parameters can’t be cloned to the paired scanner in disconnected status.
Clone Save Configuration
The below host interface related parameters will be impacted by clone function:
Data Transmission Parameter
Field Delimiter
Data Transmission Format
Host Interface Control
Host interface Selection
Keyboard Interface Control
Keyboard Layout
Intermessage Delay
Interfunction Delay
Intercharacter Delay
Caps Lock Control
Caps Lock Release Control
Function Key Emulation
Key Pad Emulation
Upper/Lower Case
Serial Interface Control
Handshaking Protocol
Intermessage Delay
Interfunction Delay
Intercharacter Delay
Baud Rate
Data Frame
Time Out Control
Wand Emulation Control
Output Polarity
Initial Signal State
Margin Time
Module Time
Narrow/Wide Ratio
Code39 Emulation
6
Getting Started
Using FuzzyScan in HID Mode
Ensure the battery is fully charged. Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “ Uninstall ” state). If the scanner is not in uninstall state, please scan the
“Uninstall” command first. Then scan the “HID Mode” command, and the link indicator of scanner will give 3 blue blinks per 2 seconds.
Uninstall HID Mode
Execute the Bluetooth Discovery procedure to find all available Bluetooth devices in your remote host. You will see ‘’CINO
FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already.
Double click the “CINO FxxxBT-xxxx” in the discovered Bluetooth device list. If the PIN Code or Passkey is requested for security connection, please enter “ 00000000 ” (default setting). You will see “Keyboard on CINO FxxxBT-xxxx”, and double click this HID service to establish the connection between the scanner and the remote host device.
The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state.
Please note that if the scanner is not connected to the host device within 1 minute after scanning the “HID Mode” command, the scanner will go to sleep automatically. You just need to press the trigger to wake up the scanner to continue the installation.
1. The installation procedures vary on different remote host devices, operation systems and the Bluetooth software driver.
Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the installation processes.
2. While using HID mode, beware of potential error in the data transmitted at the same time when radio link quality is poor.
You are suggested to use the scanner under the communication coverage all the times.
7
Getting Started
Using FuzzyScan in SPP Mode
Establish SPP Master Connection
Ensure the battery is fully charged. Please go to the folder of “ Hardware ” located in Bluetooth Advanced Setting of the remote host device to check its device MAC address. Then prepare a 12-character Code 128 barcode of the remote host device MAC address, or follow the step 4 to input MAC address by scanning 12 option codes.
Ensure a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder of
“ Local Services ” located in Bluetooth Advanced Setting. Click the “ Add Serial Services ” to add one more Bluetooth
COM port.
Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “ Uninstall ” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “SPP Master Mode” command, and the status indicator of scanner will turn steady red.
Uninstall SPP Master Mode
Scan a 12-character MAC address barcode, or scan 12 option codes and “FIN” command to confirm your inputs. The scanner will give continuous short clicks and the link indicator of the scanner will flash blue quickly during the radio connecting process. If the PIN Code or Passkey is requested for security connection, please enter “ 00000000 ” (default setting).
The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state.
Please note that if the scanner failed to connect to the host device within 30 seconds, the link indicator will give 3 blue blinks per 2 seconds. But the scanner is still continuing to discover the host device for another 30 seconds before go to sleep. In the interim, you still can scan “Uninstall” command to revert the scanner to uninstall state. If the scanner goes to sleep already, you just need to press the trigger to wake up the scanner to continue the installation.
The installation procedures vary on different remote host devices, operating systems and the Bluetooth software driver.
Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the installation processes.
8
Getting Started
Establish SPP Slave Connection
Ensure the battery is fully charged and a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder of “ Client Applications ” located in Bluetooth Advanced Setting. Click the “ Add COM Port ” to add one more Bluetooth COM port.
Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “ Uninstall ” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “SPP Slave Mode” command, and the link indicator of scanner will give 3 blue blinks per 2 seconds.
Uninstall SPP Slave Mode
Execute the Bluetooth Discovery procedure to find all available Bluetooth device list in your remote host. You will see
‘’CINO FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already.
Double click the “CINO FxxxBT-xxxx” on the discovered Bluetooth devices. If the PIN Code or Passkey is requested for security connection, please enter “ 00000000 ” (default setting). You will see “Serial Port on CINO FxxxBT-xxxx”, and double click this SPP service to establish the connection between the scanner and the remote host device.
The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state.
Please note that if the scanner is not connected to the host device within 1 minute, the scanner will go to sleep. You can press the trigger to wake up the scanner to continue the installation.
The installation procedures vary on different remote host devices, operating systems and the Bluetooth software drivers.
Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the installation processes.
9
Getting Started
Out-of-range Scanning
When the radio is connected between the scanner and the remote host device, the scanner will transmit each scanned data right after scanning the barcode. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection with the remote host device.
If you enable the out-of-range scanning function, the scanner is able to continue scanning barcode data while it is out of working range. All scanned data will be temporarily stored into the memory buffer until radio link resumed.
Enable Out-of-range Scannning Disable Out-of-range Scanning ◆
In case of the scanner is out of working range, you will hear 4 beeps in descending tone to indicate the radio connection lost.
The link indicator of scanner will give 3 blue blinks per 2 seconds. Once the scanner is back to working range, you will hear 4 beeps in ascending tone to indicate the radio connection rebuilt and the scanner will give 1 blue blink per 2.5 seconds. At the same time, all stored scanned data will be transmitted automatically right after the radio link is resumed.
Presentation Scanning
The Presentation Scanning is designed for hand-free applications for user’s convenience. If the “Presentation Scanning
Auto-sense” function is enabled, the scanner is capable of automatically switching to presentation mode when you place it onto the SmartStand or cradle.
Enable Presentation Scanning Auto-sense
Disable Presentation Scanning Auto-sense ◆
Paging Function
The paging function is helpful for you to locate the paired smart cradle or scanner. If you would like to page the paired smart cradle, you can scan “Paging” command. If you would like to page the paired scanner, you can press the paging/rest button of the smart cradle no longer than 3 seconds.
Paging
Paging/Reset Button
10
Getting Started
Batch Scanning (Inventory Mode)
Thanks to the specially designed Batch Scanning function, the scanner is capable of storing the barcode data up to 20,000
EAN-13 labels. It is an ideal cost-saving solution for inventory applications.
Once you scan the “Enter Batch Scanning” command to activate this function, all scanned barcode data will be stored into the memory storage, and the status indicator of scanner will give green blink at regular interval during batch scanning. You can scan and store the barcode data till the memory storage is full. If the storage is full, you will hear 2 long beeps and the status indicator will give 2 red blinks to indicate out of storage. To terminate the batch scanning, please scan the “Exit Batch
Scanning” command.
Enter Batch Scanning
How to Transmit Stored Data
Exit Batching Scanning
The scanner is preset to scan the “Transmit Stored Data” command to transmit all stored data. During the transmission process, the scanner will give continuous short clicks and blue blinks. Then the scanner will give two short beeps after data transmission is completed.
Transmit Stored Data
But you are still able to set the scanner to transmit the stored data by placing the scanner onto the cradle as well.
Transmit Stored Data by Scanning
Barcode Command ◆
Transmit Stored Data by Scanning Barcode or Placing Scanner onto Cradle
Transmit Stored Data by
Placing Scanner onto Cradle
The scanner is preset to keep all the stored data until you scan the “Clear All Stored Data” command. But you are still able to change the setting to “Auto Delete Stored Data after Transmission” as well.
Clear All Stored Data
11
Getting Started
Auto Delete Stored Data after Transmission
Keep Stored Data after
Transmission ◆
If you scanned a wrong barcode, the “Delete Last Scanned Data’’ command is helpful to recover mistake. By scanning the
‘’Delete Last Scanned Data’’ command, the last stored data can be deleted.
Delete Last Scanned Data
Using Quantity Feature
If you want to input the quantity information of barcode data, you can enter the quantity from 1 to 9999 by scanning the quantity barcodes right after you scanned the barcode data. The quantity information will be stored into the memory storage together with the barcode data.
Quantity 0 Quantity 5
Quantity 3 Quantity 8
Quantity 1 Quantity 6
Quantity 4 Quantity 9
Quantity 2 Quantity 7
There are two ways to output the stored barcode data and quantity information. Please refer to following for details:
Stored data is transmitted as many times as the quantity indicated.
Stored data is transmitted together with quantity information in two fields. Please scan “Enable Quantity Field
Transmission” command to enable this function. The preset delimiter is “ , “, but you are able to choose your desired one from FuzzyScan Wireless Reference Manual for details.
Disable Quantity Field Transmission ◆ Enable Quantity Field Transmission
12
Bar Code Programming Menu
Configure Your FuzzyScan
The FuzzyScan bar code commands are specially designed
Proprietary bar code labels which allow you to set the
FuzzyScan internal programming parameters. There are
System Command , Family Code and Option Code for programming purpose.
Each programmable family and bar code command label is listed on the same page with major system commands. The detailed explanations and special programming flowchart are printed on facing or following pages. You can read the explanation and set the FuzzyScan concurrently.
A supplemental bar code command menu incorporates the bar code command labels of System Command and Option
Code. As you set the FuzzyScan, open the bar code command menu to find the option code page. You may scan the desired family code and option code to set FuzzyScan. If you want to change the programming family for multiple settings, you need only turn over the programming page to find next desired programming family.
The System Command is the highest level bar code command which directs FuzzyScan to perform immediate operations, such as entering programming mode
( PROGRAM ), exiting programming mode ( EXIT ), listing system information ( SYSLIST ), recovering to factory preset configurations ( M_DEFAULT ), and so on. Please note that all system commands will take a few seconds to complete the operations. User must wait for the completion beeps before scanning another bar code.
The Family Code is scanned to select the user desired programming family. FuzzyScan has already provided more than one hundred programming families to meet any specific requirements.
The Option Codes is a set of bar code commands represented by “ 0–9 ”, “ A–F ” and finishing selection ( FIN ).
For most setting, you must select at least one option code following the family code selection to set the desired parameter for the selected programming family.
13
As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the
FuzzyScan’s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options. You need not re-program the FuzzyScan if you want to keep the existing configurations in the next power on.
The programming procedures of FuzzyScan are designed as simple as possible for ease of setting. Most programming families take the Single Scan Selection programming procedure. But several programming families have more complex and flexible programmable options, and you must take Multiple Scans Selection, Cycling
Scan Selection or Dual Level Selection to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference.
Please give careful attention to become familiar with each programming procedure.
Configure Your FuzzyScan
If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of
Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details.
Before setting the FuzzyScan, please also refer to the
“Beeping Indications” listed in Appendix to understand the details of programming beeping indications. It will be very helpful for you to know the existing status while you are programming the FuzzyScan.
Conventions
P.C.
( )
[ ]
Descriptions
Factory Default Value
Programming Category
SS : Signle scan selection
MS : Multiple scans selection
CS : Cycling scan selection
DS : Dual level scan selection
Necessary Option Code
Selectable Option Code
14
Configure Your FuzzyScan
Scan
“ PROGRAM ”
FuzzyScan will enter programming mode, and inhibit all non-programming functions.
Scan
“ END ”
FuzzyScan will exit programming mode, and store all parameters in Flash Memory ASIC or non-volatile memory, then issue the completion beeping.
Please note that the FuzzyScan will take 3-4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the “ END ”. Please don’t turn off the power before the completion beeping. It may destroy all configured parameters.
Scan
“ SYSLIST ”
FuzzyScan will list the product information and revision number to host via selected host interface, then issue the completion beeping.
Scan
“ M_DEFAULT ”
FuzzyScan will recover all programmable parameters into factory preset configurations, then issue the completion beeping.
15
“
Scan
PROGRAM ”
Scan
One of Family Codes
Scan
One of Option Codes
Yes
Repeat
Selection
No
Scan
“ END ”
Enter programming mode.
Select one of desired programming families.
Select one option code of desired parameter.
Want to select another programming family?
Exit programming mode.
Configure Your FuzzyScan
Yes
“
Scan
PROGRAM”
Scan
One of Family Codes
Scan One or
Several Option Codes
Repeat
Selection
No
Scan
“ END ”
Enter programming mode.
Select one of desired programming families.
1. Select one or several option codes to select desired parameters.
2. If it’s necessary, scan
“FIN” to terminate option code selection.
Want to select another programming family?
Exit programming mode.
16
Yes
Scan
“PROGRAM”
One of
Scan
Family
Repeat
Selection
Codes
Scan
One of Option Codes
Scan “ FIN ”
Scan
“ END ”
No
Enter programming mode.
Select one of desired programming families.
Cycling select one or several option codes of desired parameters as
“Single” or “Multiple” scans selection.
Finish cycling selection.
(If necessary)
Want to select another programming family?
Exit programming mode.
Configure Your FuzzyScan
Yes
“
Scan
PROGRAM
One of
Repeat
Selection
No
Scan
“ END ”
”
( 1st ) Scan
Several Option Codes
( 2nd
Scan
Family Codes
) Scan One or
Several Option Codes
Enter programming mode.
Select one of desired programming families.
Select several option codes of desired parameters.
1. Select one or several option codes of desired parameters.
2. If it’s necessary, scan
“FIN” to terminate option code selection.
Want to select another programming family?
Exit programming mode.
17
Configure Your FuzzyScan
Host Interface Selection
PROGRAM
Family Code Selection
Host Interface Selection
P.C
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
Parameter Selection
IBM PS/2, 25-30 series keyboard wedge interface
Standard/TTL RS-232 peer-to-peer serial
Wand emulation
USB Com Port Emulation
PS/2 (DOS/V) direct link (keyboard replacement)
PS/2 (DOS/V) keyboard wedge turbo mode
PS/2 (DOS/V) keyboard wedge standard mode
Laser emulation
USB HID standard mode
USB HID turbo mode
F_DEFAULT
Option Code
02
06
08
09
10
13
14
17
18
19
18
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Symbol ID : 1 character
Symbology Reading Control
♦
User Defined Symbol ID
♦
P.C Parameter Selection
DS Code 128 (default= B )
UCC/EAN-128 (default= C )
UPC-A (default= A )
EAN-13 (default= F )
Codabar/NW-7 (default= D )
Code 39/Code 32 (default= G )
Code 93 (default= H )
Standard/Industrial 2 of 5 (default= I )
Interleaved 2 of 5 (default= J )
Matrix 2 of 5 (default= K )
China Postal Code (default= L )
German Postal Code (default= M )
IATA (default= O )
Code 11 (default= P )
MSI/Plessey (default= R )
UK/Plessey (default= S )
Telepen (default= T )
GS1 DataBar (default= X )
UPC-E (default= E )
EAN-8 (default= N )
Trioptic Code 39 (Default= W )
UCC Coupon Extended Code (Default= Z )
PDF417/Micro PDF417 (default= V )
Codablock F (default= Y )
Korea Post Code (default = a )
Option Code
10
11
12
13
14
06
07
08
09
00
01
02
03
04
05
19
20
21
22
15
16
17
18
23
26
F_DEFAULT
2nd Option Code
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
19
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Symbology ID Transmission
Symbology Reading Control
♦
Symbology ID Transmission
♦
P.C
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable symbology ID transmission
Enable prefix CINO symbology ID transmission
Enable suffix CINO symbology ID transmission
Enable both prefix and suffix CINO symbology ID transmission
Enable prefix AIM symbology ID transmission
Enable suffix AIM symbology ID transmission
Enable both prefix and suffix AIM symbology ID transmission
F_DEFAULT
Option Code
5
6
3
4
0
1
2
20
Configure Your FuzzyScan
Symbology Reading Control
♦
Readable Bar Code Setting
♦
PROGRAM F_DEFAULT
Family Code Selection
Readable Symbology Setting
Remember to scan “FIN” to terminate this selection. But if you select the
“ Auto ” , FuzzyScan will terminate this selection automatically .
P.C
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
SS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
Auto
Code 128 *
UPC-A *
UPC-E *
EAN-13 *
EAN-8 *
Codabar/NW-7 *
Code 39 *
Trioptic Code 39
Standard/Industrial 2 of 5
Matrix 2 of 5
Interleaved 2 of 5 *
China Postal Code
German Postal Code
Code 93 *
Code 11
MSI/Plessey
UK/Plessey
Telepen
GS1 DataBar (RSS-14) *
IATA
PDF417/Micro PDF417
Codablock F
Korea Post Code
Parameter Selection Option Code
48
58
68
09
07
47
08
38
00
01
02
03
04
05
06
14
15
17
18
21
10
11
12
13
If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add the “ Symbology ID ” into the transmitted data is also helpful to identify the specific symbology.
Above symbologies marketed with * are enable as default. When you select “Auto”, the scanner only read those symbologies marked with *
When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.
21
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Code 39 Family Setting
Symbology Reading Control
♦
Code 39/Code 32 Setting
♦
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable Code 39
Enable Code 39
Select Standard Code 39 as primary format
Select Full ASCII Code 39 as primary format
Select Code 32 (PARAF, Italian Pharmaceutical) as primary format
Disable start/stop symbol transmission
Enable start/stop symbol transmission
Disable Code 32 leading A transmission
Enable Code 32 leading A transmission
Disable MOD 43 check digit verification
Enable MOD 43 check digit verification
Disable check digit transmission
Enable check digit transmission
Disable Code 39 buffering
Enable Code 39 buffering
Disable Trioptic Code 39
Enable Trioptic Code 39
Trioptic Code 39 Setting
Code 39 Min. Length
SS
MS
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Code 39 Max. Length
SS
MS
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
22
F_DEFAULT
Option Code
C
D
E
7
8
9
A
B
5
6
3
4
0
1
2
0
1
FIN
(2 digits)
FIN
(2 digits)
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Codabar Setting
Codabar Min. Length
Codabar Max. Length
Symbology Reading Control
♦
Codabar/NW-7 Setting
♦
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
MS
SS
MS
Parameter Selection
Disable Codabar
Enable Codabar
Select Codabar standard format
Select Codabar ABC format
Select Codabar CLSI format
Select Codabar CX format
Disable start/stop symbol transmission
Enable ABCD/ABCD start/stop symbol transmission
Enable abcd/abcd start/stop symbol transmission
Enable ABCD/TN*E start/stop symbol transmission
Enable abcd/tn*e start/stop symbol transmission
Disable check digit verification
Enable check digit verification
Disable check digit transmission
Enable check digit transmission
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
9
A
B
C
D
E
7
8
5
6
2
3
0
1
4
FIN
(2 digits)
FIN
(2 digits)
23
Configure Your FuzzyScan
Symbology Reading Control
♦
UPC-A & UPC-E Setting
♦
PROGRAM F_DEFAULT
Family Code Selection
UPC Family Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable UPC-A
Enable UPC-A
Disable UPC-E
Enable UPC-E
Disable UPC-E expansion
Enable UPC-E expansion
Disable UPC standardization
Enable UPC standardization
Disable UPC numeric system
Enable UPC numeric system
Disable UPC-A check digit transmission
Enable UPC-A check digit transmission
Disable UPC-E check digit transmission
Enable UPC-E check digit transmission
Disable UPC “leading 1” portion
Enable UPC “leading 1” portion
Option Code
C
D
E
F
7
8
9
A
B
5
6
3
4
0
1
2
When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric system, UPC-A check digit transmission.
24
Configure Your FuzzyScan
Symbology Reading Control
♦
UPC-A & UPC-E Setting
♦
PROGRAM F_DEFAULT
Family Code Selection
UPC Supplement Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Select UPC without supplement digits
Select UPC with only 2 supplement digits
Select UPC with only 5 supplement digits
Select UPC with 2/5 supplement digits
Disable force supplement digits output
Enable force supplement digits output
UPC Family Addenda Separator Off
UPC Family Addenda Separator On
UPC-E & EAN-8 Expansion
UPC-A/E Standardization
UPC Lead 1 Numeric System
WPC Selection
(UPC/EAN/CAN)
UPC-A
UPC-E
EAN-13
EAN-8
12
8
13
8
:
: Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.
: Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.
Enable to read UPC leading with the 1 numeric system, you must enable this option.
Basic Length
Disable
Check Digit
- 1
- 1
- 1
- 1
Disable
Numeric System
- 1
- 1
NC
NC
With 2-digit
Addendum
+ 2
+ 2
+ 2
+ 2
With 5-digit
Addendum
+ 5
+ 5
+ 5
+ 5
Enable
Standardization
+ 1
+ 1
NC
NC
Option Code
5
6
3
4
7
0
1
2
Enable
Expansion
0
+ 4
0
+ 5
25
Configure Your FuzzyScan
PROGRAM
Family Code Selection
EAN Setting
EAN Supplement Setting
Symbology Reading Control
♦
EAN Setting
♦
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable EAN-13
Enable EAN-13
Disable EAN-8
Enable EAN-8
Disable EAN-8 expansion
Enable EAN-8 expansion
Disable EAN-13 check digit transmission
Enable EAN-13 check digit transmission
Disable EAN-8 check digit transmission
Enable EAN-8 check digit transmission
Disable ISBN/ISSN Conversion reading check
Enable ISBN/ISSN Conversion reading check
Select EAN without supplement digits
Select EAN with only 2 supplement digits
Select EAN with only 5 supplement digits
Select EAN with 2/5 supplement digits
Disable force supplement digits output
Enable force supplement digits output
EAN Addenda Separator Off
EAN Addenda Separator On
F_DEFAULT
Option Code
5
6
3
4
0
1
2
7
8
9
A
B
5
6
3
4
7
0
1
2
26
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Family Code Selection
UPC/EAN Security Level
♦
UPC/EAN Security Level Setting
♦
P.C
SS
SS
SS
Parameter Selection
Level 0
Level 1
Level 2
Only available for UPC-A & EAN-13
F_DEFAULT
Option Code
0
1
2
UPC/EAN Security Level
The scanner offers three levels of decode security for UPC/EAN bar codes:
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may significantly impair the decoding ability of the scanner.
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may increase the misread.
27
Configure Your FuzzyScan
PROGRAM
Family Code Selection
UCC Coupon Extended Code
♦
Symbology Reading Control
UCC Coupon Extended Code Setting
P.C
SS
SS
Parameter Selection
Disable UCC Coupon Extended Code
Enable UCC Coupon Extended Code
♦
F_DEFAULT
Option Code
0
1
UCC Coupon Extended Code
When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and UCC/EAN-128
Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.
28
Configure Your FuzzyScan
PROGRAM
Family Code Selection
IATA Setting
Interleaved 2 of 5 Setting
♦
Symbology Reading Control
IATA & Interleaved 2 of 5 Setting
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable IATA
Enable IATA
Select 15-digit fixed length IATA checking
Select variable length IATA
Disable check digit verification
Enable check digit automatic verification
Enable S/N checking digit verification only
Enable CPN checking digit verification only
Enable CPN, Airline and S/N check digit verification
Disable check digit transmission
Enable check digit transmission
Disable start/stop symbol transmission
Enable start/stop symbol transmission
Disable Interleaved 2 of 5
Enable Interleaved 2 of 5
Select Interleaved 2 of 5 as primary format
Select German Postal Code as primary format
No check character
Validate USS check digit
Validate OPCC check digit
Disable check digit transmission
Enable check digit transmission
♦
F_DEFAULT
Option Code
7
8
9
A
B
C
5
6
3
4
0
1
2
6
7
4
5
8
0
1
2
3
29
Configure Your FuzzyScan
Symbology Reading Control
PROGRAM
Code 25 Setting
Family Code Selection P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
♦
Code 25 Family Setting
♦
Parameter Selection
Disable Standard/Industrial 2 of 5
Enable Standard/Industrial 2 of 5
Disable Matrix 2 of 5
Enable Matrix 2 of 5
Disable China Postal Code
Enable China Postal Code
Disable check digit verification
Enable check digit verification
Disable check digit transmission
Enable check digit transmission
F_DEFAULT
Option Code
5
6
3
4
0
1
2
7
8
9
Code 25 Family Min. Length
SS
MS
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
Code 25 Family Max. Length
SS
MS
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
For Code25 setting, we recommend you to select only one type of Code 25 or set the maximum/minimum bar code length.
To decode all types of Code 25 or to variable length of Code 25 will increase the possibility of reading error.
30
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Code 11 Setting
Code 11 Min. Length
Code 11 Max. Length
Code 93 Setting
Code 93 Min. Length
Code 93 Max. Length
Symbology Reading Control
♦
Code 11 & Code 93 Setting
♦
P.C
SS
SS
SS
SS
SS
SS
SS
SS
MS
Parameter Selection
Disable Code 11
Enable Code 11
Disable check digit verification
Select 1-check digit verification
Select 2-check digit verification
Disable check digit transmission
Enable check digit transmission
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
SS
MS
SS
SS
SS
SS
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Disable Code 93
Enable Code 93
Disable check digit transmission
Enable check digit transmission
SS
MS
SS
MS
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
31
F_DEFAULT
Option Code
4
5
6
2
3
0
1
FIN
(2 digits)
FIN
(2 digits)
2
3
0
1
FIN
(2 digits)
FIN
(2 digits)
Configure Your FuzzyScan
PROGRAM
Family Code Selection
MSI/Plessey Setting
MSI/Plessey Min. Length
MSI/Plessey Max. Length
Symbology Reading Control
♦
MSI/Plessey Setting
♦
P.C
SS
SS
SS
SS
SS
SS
SS
SS
MS
Parameter Selection
Disable MSI/Plessy
Enable MSI/Plessy
Select MOD 10 check digit
Select MOD 10-10 check digit
Select MOD 11-10 check digit
Disable check digit transmission
Enable check digit transmission
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
SS
MS
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
4
5
6
2
3
0
1
FIN
(2 digits)
FIN
(2 digits)
32
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Code 128/EAN-128 Setting
Code 128/EAN-128 Min. Length
Code 128/EAN-128 Max. Length
♦
Symbology Reading Control
Code 128 & UCC/EAN 128 Setting
♦
P.C
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable Code 128 and UCC/EAN-128
Enable Code 128 and UCC/EAN-128
Disable function code conversion
Enable function code conversion
ISBT Concatenation Off
ISBT Concatenation On
SS
MS
SS
MS
Default (01)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
2
3
0
1
4
5
FIN
(2 digits)
FIN
(2 digits)
33
Configure Your FuzzyScan
PROGRAM
Family Code Selection
UK/Plessey Setting
UK/Plessey Min. Length
UK/Plessey Max. Length
Symbology Reading Control
♦
UK/Plessey Setting
♦
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
MS
Parameter Selection
Disable UK/Plessey
Enable UK/Plessey
Select UK/Plessey Standard Format
Select UK/Plessey CLSI Format
Disable Convert X to A-F
Enable Convert X to A-F
Disable check digit transmission
Enable check digit transmission
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
SS
MS
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
5
6
3
4
7
0
1
2
FIN
(2 digits)
FIN
(2 digits)
34
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Telepen Setting
Telepen Min. Length
Telepen Max. Length
Symbology Reading Control
♦
Telepen Setting
♦
P.C
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable Telepen
Enable Telepen
Select Telepen Numeric mode
Select Telepen Full ASCII mode
Disable check digit transmission
Enable check digit transmission
SS
MS
SS
MS
Default (04)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (98)
98-Minimum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
3
4
5
0
1
2
FIN
(2 digits)
FIN
(2 digits)
35
Configure Your FuzzyScan
PROGRAM
Family Code Selection
GS1 DataBar Setting
GS1 DataBar Min. Length
GS1 DataBar Max. Length
Symbology Reading Control
♦
GS1 DataBar Setting
♦
P.C
SS
SS
SS
SS
SS
SS
Parameter Selection
Disable GS1 DataBar (RSS-14)
Enable GS1 DataBar (RSS-14)
Disable GS1 DataBar Limited
Enable GS1 DataBar Limited
Disable GS1 DataBar Expanded
Enable GS1 DataBar Expanded
SS
MS
SS
MS
Default (04)
01-Maximum
Only available for Expanded GS1 Databar.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Default (74)
74-Minimum
Only available for Expanded GS1 Databar.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
3
4
5
0
1
2
FIN
(2 digits)
FIN
(2 digits)
36
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Composite Codes Setting
PDF417/MicroPDF417 Setting
P.C
SS
SS
SS
SS
♦
Symbology Reading Control
Linear-stacked & Korea Post Code Setting
Parameter Selection
Disable composite codes
Enable composite codes
UPC Composite Mode: UPC never linked
UPC Composite Mode: UPC always linked
♦
SS
SS
SS
SS
Disable PDF417
Enable PDF417
Disable MicroPDF417
Enable MicroPDF417
Codablock F Setting
SS
SS
Disable
Enable
Korea Post Code Setting
SS
SS
Disable
Enable
Length fixed in 6 characters.
Composite Codes Setting
If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected.
If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.
F_DEFAULT
Option Code
0
1
2
3
0
1
2
3
0
1
0
1
37
Configure Your FuzzyScan
Keyboard Interface Control
PROGRAM
Family Code Selection
Keyboard Layout
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
♦
Keyboard Layout (Language) Setting
Parameter Selection
USA (QWERTY)
France (AZERTY)
Germany (QWERTZ)
United Kingdom - UK (QWERTY)
Canadian French (QWERTY)
Spain (QWERTY)
Sweden/Finland (QWERTY)
Portugal (QWERTY)
Norway (QWERTY)
Latin America (QWERTY)
Italy (QWERTY)
Netherlands (QWERTY)
Denmark (QWERTY)
Belgium (AZERTY)
Switzerland-Germany (QWERTY)
Iceland (QWERTY)
Japan (DOS/V)
Universal * (see note)
♦
F_DEFAULT
Option Code
04
05
06
07
08
09
00
01
02
03
10
11
12
13
14
15
16
99
The “ Universal Selection ” is only for PC/AT, PS/VP, PS/2 and compatible ones in DOS or Windows environment which can perform unique output without Caps Lock on/off (Output Style) concern. All transmitted data will follow the original full ASCII form. You also need not worry about the upper/lower case control.
Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as premble or postamble.
To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first.
Keyboard Interface Message String :
Preamble
1-15 characters
Data Length
2-3 digits
Prefix Symbol ID
1 or 2 characters
Scanned Data
Variable length
Suffix Symbol ID
1 or 2 characters
Postamble
1-15 characters
Record Suffix
1 character
38
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Record Suffix
Preamble
Postamble
Caps Lock Control
♦
Keyboard Interface Control
Record Suffix, Preamble, Postamble & Caps Lock
♦
P.C
SS
SS
SS
SS
SS
SS
Parameter Selection
None
RETURN
TAB
SPACE
ENTER (Numeric Key Pad)
User defined character (1 character)
SS
MS
SS
MS
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
SS
SS
SS
“Caps Lock Off” State
“Caps Lock On” State
Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)
F_DEFAULT
Option Code
2
3
0
1
4
5, (00-7F)
FIN
[00-7F], [FIN]
FIN
[00-7F], [FIN]
0
1
2
Caps Lock Release Control
SS
SS
“Caps Lock On, Caps Off”
“Caps Lock On, Shift Off”
0
1
The function of “ Caps Lock Control ” and “ Key Pad Emulation ” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines.
While selecting the other host interfaces, these selections don’t perform the above functions for you.
Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “ Caps Lock Off ” state, then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select “ Caps Lock On ” state. Select “ Auto Detect ”, FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch.
39
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Intermessage Delay
Keyboard Interface Control
♦
Delay Setting
♦
P.C
SS
MS
Parameter Selection
None
1-99 (x10) msec .
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
FIN
(2 digits)
Intercharacter Delay
SS
MS
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
Interfunction Delay
SS
MS
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters.
Interfunction Delay is a time delay between the transmission of each segment of the message string.
Intermessage Delay, Intercharacter Delay and Interfunction Delay cannot be only worked under SPP and HID modes.
40
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Function Key Emulation
Key Pad Emulation
♦
Keyboard Interface Control
Emulation Setting & Upper/Lower Case Setting
P.C
SS
SS
Parameter Selection
Enable ASCII 00-31 code as keyboard function code output
Ctrl-Output
Refer to Appendix – Keyboard Function Code Table for details.
SS
SS
Disable key pad emulation
Enable numeric output as key pad (Num Lock On) output
♦
Upper/Lower Case
SS
SS
SS
SS
Normal case (neglect the upper/lower case control)
Inverse case (change all characters output to inverse case)
Upper case (force all characters output as upper case)
Lower case (force all characters output as lower case)
F_DEFAULT
Option Code
0
1
0
1
2
3
0
1
41
Configure Your FuzzyScan
PROGRAM
Family Code Selection
STX/ETX Control
Record Suffix
Preamble
♦
Serial Interface Control
Record Suffix, Preamble ,Postamble Setting
♦
SS
SS
SS
SS
SS
SS
MS
SS
MS
P.C
SS
SS
Parameter Selection
Disable STX/ETX transmission
Enable STX/ETX transmission
STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
None
CR (0DH)
LF (0AH)
CRLF (0D0AH)
TAB (09H)
SPACE (20H)
User defined character (1 character)
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
Postamble
SS
MS
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
Serial Interface Message String (RS232, USB COM) :
STX Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID
1 character 1-15 characters 2-3 digits
Postamble
1 or 2 characters Variable length 1 or 2 characters 1-15 characters
ETX
1 character
F_DEFAULT
Option Code
0
1
0
1
2
3
4
5
6, (00-7F)
FIN
[00-7F], [FIN]
FIN
[00-7F], [FIN]
Record Suffix
1 character
42
Configure Your FuzzyScan
Serial Interface Control
♦
Delay Setting
♦
PROGRAM
Family Code Selection
Intermessage Delay
P.C
SS
MS
Parameter Selection
None
1-99 (x10) msec .
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT
Option Code
FIN
(2 digits)
Intercharacter Delay
SS
MS
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
Interfunction Delay
SS
MS
None
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN
(2 digits)
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters.
Interfunction Delay is a time delay between the transmission of each segment of the message string.
Intermessage Delay , Intercharacter Delay and Interfunction Delay cannot be only worked under SPP and HID modes.
43
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Handshaking Protocol
♦
Serial Interface Control
Protocol, Baud Rate, Data Frame & Time Out Setting
♦
P.C
SS
SS
SS
SS
Parameter Selection
None (free running mode)
RTS/CTS (hardware handshaking)
ACK/NAK (software handshaking)
Xon/Xoff (software handshaking)
F_DEFAULT
Option Code
0
1
2
3
Baud Rate (BPS)
Data Frame
Serial Response Time-out
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
MS
38.4K BPS
19.2K BPS
9600 BPS
4800 BPS
2400 BPS
8, None, 1
8, Odd, 1
8, Even, 1
8, Space, 1
8, Mark, 1
8, None, 2
7, Odd, 1
7, Even, 1
None
200 mseconds
500 mseconds
1200 BPS
600 BPS
300 BPS
57.6K BPS
115.2K BPS
7, Space, 1
7, Mark, 1
7, None, 2
7, Odd, 2
7, Even, 2
7, Space, 2
7, Mark, 2
1 second
2 seconds
5 seconds
User defined value (seconds)
0
1
2
3
4
6
7
4
5
2
3
0
1
0
1
2
C
D
E
8
9
A
B
7
8
5
6
9
3
4
5
6, (2 digits)
When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication.
When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.
The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.
44
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Output Polarity
Initial Signal State
Margin Time
Module Time
Narrow/Wide Ratio
Wand/Laser Emulation Control
♦
Output Polarity, Signal State, Margin/Module Time, etc.
♦
P.C
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
High level (5Vdc) on Bar (low level on Space)
Low level (0Vdc) on Bar (high level on Space)
Determine the output voltage level for both bar and space.
High Level (5Vdc)
Low Level (0Vdc)
Determine the initial state of output voltage level.
10 msec.
15 msec.
20 msec.
25 msec.
30 msec.
50 msec.
100 msec.
Delay time before data transmission
SS
SS
SS
Extremely short
Short
Medium
Long
Time base of minimum narrow bar
SS
SS
SS
1:2
1:2.5
1:3
0
1
2
0
1
2
3
F_DEFAULT
Option Code
0
1
0
1
2
0
1
4
5
6
3
Code 39/Code 128 Emulation
SS
SS
SS
SS
SS
Disable standard Code 39 emulation
Enable Full ASCII Code 39 emulation
Enable Code 128 emulation
Enable standard Code 39 skip emulation
Enable standard Code 39 replace emulation
0
1
2
3
4
[ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped .
[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space.
45
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Operation Mode
P.C
SS
SS
Trigger mode
Presentation mode
Operation Control
♦
Operation Mode
♦
Parameter Selection
F_DEFAULT
Option Code
1
2
Trigger Mode (Low Power Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner before scanning the bar code.
Presentation Mode (Auto Detection) Presentation mode uses ambient light to detect the bar codes. The light source is off until the scanner detects an image which is similar to a barcode. Then the light source turns on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work properly. You can choose different level of “Presentation Sensitivity” to meet your application (Please refer to the setting of “ Presentation Sensitivity ”).
46
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Buzzer Tone Adjust
Power On Indicator
Vibrator Control
Inverse Reading
Operation Control
♦
Buzzer, Indicator, Vibrator, Inverse Reading, Dollar Sign
♦
P.C
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Parameter Selection
Buzzer tone – mute
Buzzer tone – low
Buzzer tone – medium
Buzzer tone – high
Buzzer tone - extremely high
Power-on beep
No power-on beep
Disable (LED off)
LED steady on
LED flash
Disable
Enable
Optional function, only available for vibrator model.
SS
SS
Disable
Enable
Dollar Sign Control
SS
SS
SS
SS
SS
Dollar sign output as “ $ “
Dollar sign output as “
¥
“
Dollar sign output as “ € “
Dollar sign output as “ £ “
Dollar sign output as “ ¢ “
F_DEFAULT
Option Code
4
5
6
2
3
0
1
0
1
2
0
1
2
3
4
0
1
0
1
47
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Flash Duty Cycle
♦
Operation Control
Flash Duty Cycle, Redundancy, Delay Setting
♦
P.C
SS
SS
SS
SS
1/2 duty cycle
2/3 duty cycle
3/4 duty cycle
4/5 duty cycle
Parameter Selection
F_DEFAULT
Option Code
0
1
2
3
Redundancy (Scan Voting)
Reread Delay
(Double Scan Verification)
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
None
Level 1
Level 2
Level 3
Level 4
Level 5
To prevent potential miss reading.
Disable
Immediate time out
Short time out
Medium time out
Long time out
Force verification
2
3
0
1
4
5
2
3
0
1
4
5
Good Read Delay SS
SS
SS
SS
SS
SS
SS
None
200 msec.
500 msec.
1 sec.
1.5 sec.
2 sec.
3 sec.
4
5
6
2
3
0
1
The Flash Duty Cycle is designed to control the flashing frequency of the light source.
The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.
The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification will not allow reading of the same bar code twice.
This Good Read Delay is the minimum amount of time before the scanner can read another bar code.
48
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Light Source On Time
♦
Operation Control
Time-out Setting, Good Read Beep Duration ♦
P.C
SS
SS
SS
SS
Short
Medium
Long
Extremely long
Parameter Selection
F_DEFAULT
Option Code
0
1
2
3
Hands Free Time-out
Good Read Duration SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Short
Medium
Long
Extremely long
Disable
Short
Medium
Long
Extremely long
Extremely short
2
3
0
1
4
2
3
0
1
4
Time Delay to Low Power Trigger SS
SS
SS
SS
SS
SS
1 sec
3 secs
5 secs
7 secs
9 secs
Immediate
3
4
5
0
1
2
The Light Source On Time is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on till the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.
The Presentation Mode is referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode when you press the trigger. You can remain the scanner in manual trigger mode by setting the Hands Free Time-Out . Once the time-out duration is up (if there’s no any trigger operation), the imager will revert to the original hands free mode.
The Time Delay to Low Power Trigger sets the time for scanner to enter low power trigger mode after any scanning activity.
49
Configure Your FuzzyScan
PROGRAM
Family Code Selection
SmartStand Power Off Timeout
Presentation Auto-sense
Operation Control
♦
Presentation Scanning Setting & Scan Rate Adjustment
♦
P.C
SS
SS
SS
Parameter Selection
3 mins
5 mins
10 mins
Only available for FuuzzyScan Laser model
SS
SS
Disable
Enable
F_DEFAULT
Option Code
0
1
2
0
1
Presentation Sensitivity
SS
SS
SS
SS
SS
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
0
1
2
3
4
5
6
The SmartStand Power Off Timeout is a pre-defined duration for scanner’s light source on time when the scanner is placed on SmartStand. While the scanner is placed on SmartStand, the scanner’s will be switched from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will be off when the pre-defined duration is up.
When enable the Presentation Auto-sense, the scanner can be switched between hands free scanning and hand-held scanning automatically when working with the
SmartStand or cradle
The Presentation Sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting the barcode.
50
Configure Your FuzzyScan
Operation Control
♦
Out-of-range Scanning, Sleep Time-out Control
♦
PROGRAM
Family Code Selection
Out-of-range Scanning
P.C
SS
SS
Disable
Enable
Parameter Selection
F_DEFAULT
Option Code
0
1
Link Supervision Time-out
SS
SS
SS
SS
SS
1 sec
3 secs
5 secs
7 secs
9 secs
Only available in PAIR & PICO modes
2
3
0
1
4
Sleep Time-out of Connect State
SS
MS
6 (x5) minutes
0-99 (x5) minutes
If you don’t want the scanner to enter sleep mode, please set time-out to “ 0 ”
FIN
(2 digits)
Sleep Time-out of Disconnect State
SS
MS
1 minute
0-99 minutes
If you don’t want the scanner to enter sleep mode, please set time-out to “ 0 ”
FIN
(2 digits)
Out-of-range Scanning When radio link is built between the scanner and remote host device, the scanner will transmit each scanned data right after scanning the barcode data. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection. You can enable the Out-of-range Scanning function to continue scanning barcode data into memory buffer until radio link resumed.
The Link Supervision Time-out is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status every preset seconds.
The Sleep Time-out Control can be set under radio connection or disconnection state. If the scanner is not used within the preset time-out duration, it will automatically enter “Sleep State” for power saving purpose. You are able to disable this function by setting the time-out duration to “0”.
51
Configure Your FuzzyScan
Operation Control
♦
Batch Scanning Setting
♦
PROGRAM
Family Code Selection
Batch Scanning Link Control
P.C
SS
SS
Radio disable
Radio enable
Parameter Selection
F_DEFAULT
Option Code
0
1
Stored Data Transmission
SS
SS
SS
All
On cradle
Scan barcode
0
1
2
Delete Stored Data after
Transmission
SS
SS
Disable
Enable
0
1
The Batch Scanning Link Control is a pre-defined radio option to control the radio-on or radio-off status under batch scanning operation. Please note that if the radio disable is activated, the radio link will be disconnected once you enter batching scanning. The radio link will be resumed when you transmit the stored data or exit batch scanning.
The Stored Data Transmission is a pre-defined approach when you want to transmit the scanned data under batch scanning operation. You can transmit the scanned data by placing the scanner onto the cradle or scanning “Transmit Stored Data” command, or by either one of both methods.
In batching scanning, the default setting of Delete Stored Data after Transmission is disable. The scanner will keep all stored data after transmission until you scan the
“Clear All Stored Data” command. You are also able to delete all stored data after transmission automatically by enabling this function.
52
Configure Your FuzzyScan
Operation Control
♦
Batch Scanning Data Transmission Setting
♦
PROGRAM
Family Code Selection
Field Delimiter
Batch Data Quantity Output Format
P.C
SS
SS
SS
SS
SS
SS
None
,
SPACE
–
.
User define
SS
SS
Parameter Selection
As many times as the quantity indicates
<Quantity><Field Delimiter><Scanned Data>
F_DEFAULT
Option Code
2
3
0
1
4
5, [00-7F]
0
1
Data Transmission Format
SS
SS
SS
Disable (scanned data only)
Leading with MAC address (MAC address and scanned data)
Leading with ID No. (scanner ID and scanned data)
Only available for RS232, USB HID and USB COM interface in PAIR & PICO modes
0
1
2
The Field Delimiter is used to separate the specific information and scanned data into two fields. You can choose desired delimiter format.
The Batch Data Quantity Output Format If you want to input the quantity information of barcode data, you can enter the quantity from 1 to 9999 by scanning the quantity barcodes right after you scanned the barcode data. The quantity information will be stored into the memory storage together with the barcode data. There are two ways to output the stored barcode data and quantity information.
In PICO mode, up to 7 scanners can be connected with one smart cradle. The Data Transmission Format can help user to identify the source of the transmitted data.
You can choose to transmit the scanned data leading with MAC address or pre-assigned ID.
Example format: <MAC address><Field Delimiter><Data> or <ID><Field Delimiter><Data>.
53
Configure Your FuzzyScan
Operation Control
♦
Bluetooth Device Name & Security Setting
♦
PROGRAM
Family Code Selection
Bluetooth Device Name
P.C
SS
MS
Parameter Selection
Default device name
User define, 1-16 characters
F_DEFAULT
Option Code
FIN
[00-7F], FIN
Bluetooth PIN Code
SS
MS
Default Bluetooth PIN Code
User define, 1-8 numbers
FIN
[30-39], FIN
Bluetooth Authentication
SS
SS
Disable
Enable
0
1
The default Bluetooth Device Name is “CINO FxxxBT-xxxx”, you will be able to change the device name by scanning HEX values (1-16 characters).
The default Bluetooth PIN Code is “00000000”, you will be able to change the PIN Code by scanning HEX values (1-8 numbers).
The Bluetooth Authentication You can enable or disable the Bluetooth Authentication between the scanner and remote host device. If this function is enabled, when the scanner wants to connect itself and sends the data to the host device, the host device has to return a link key shared between the scanner and the host device.
54
PROGRAM
Family Code Selection
HID Link Quality Setting
P.C
SS
SS
Disable
Enable
Configure Your FuzzyScan
Operation Control
♦
Bluetooth Other Settings
♦
Parameter Selection
F_DEFAULT
Option Code
0
1
Bluetooth Power Saving Mode
SS
SS
Disable
Enable
0
1
The HID Link Quality Setting While using the HID radio link mode, some errors may occur during the data transmission when the radio link is disconnected. You can enable this function to prevent such error from occurring.
The Bluetooth Power Saving Mode Bluetooth module will enter low consumption mode when you enable this function.
55
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Preamble
♦
Condensed DataWizard
Preamble, Postamble, Data Length & Symbol ID Trans.
♦
Postamble
Data Length Transmission
P.C
SS
MS
Parameter Selection
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
SS
MS
SS
SS
None
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
Disable
Enable 2 digits data length transmission
If data length exceeds 99, 3-digit data length will be transmitted.
F_DEFAULT
Option Code
FIN
[00-7F], [FIN]
FIN
[00-7F], [FIN]
0
1
Symbology ID Transmission
SS
SS
SS
SS
SS
SS
SS
Disable symbology ID transmission
Enable prefix symbology ID transmission
Enable suffix symbology ID transmission
Enable both prefix and suffix symbology ID transmission
Enable prefix AIM symbology ID transmission
Enable suffix AIM symbology ID transmission
Enable both prefix and suffix AIM symbology ID transmission
4
5
6
2
3
0
1
DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard, you can process the scanned data prior the transmissions in many ways as: Insert , Delete , Match , Verify , Replace , Reorganize , and Repeat Transmission . It will help you to arrange the transmission of scanned data to any specific format without software modification.
Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool . Through the PowerTool, all settings and configurations can be done on-screen, under Windows 95/98/NT/2000/XP environment.
A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with ease.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.
56
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Formatter Control
P.C
SS
MS
MS
Condensed DataWizard
♦
Data Formatter Setting
♦
Parameter Selection
Disable
Select one bar code symbology
Select all bar code symbologies
F_DEFAULT
Option Code 2nd Option Code
FIN
(2 digits)
00 automatic termination automatic termination
1st Insertion
2nd Insertion
SS
DS
SS
DS
Disable
Enable
2-digits identified position; max. 3 insertion characters
Disable
Enable
2-digits identified position; max. 3 insertion characters
Disable
Enable
2-digits identified position; max. 3 insertion characters
FIN
(2 digits) position
FIN
(2 digits) position
[1-3 characters], [FIN]
[1-3 characters], [FIN]
3rd Insertion
SS
DS
FIN
(2 digits) position
[1-3 characters], [FIN]
4th Insertion
SS
DS
Disable
Enable
2-digits identified position; max. 3 insertion characters
FIN
(2 digits) position
[1-3 characters], [FIN]
The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.
While the Data Formatter is enabled, it arranges only scanned data without Preamble , Postamble , STX , ETX , Data Length , Prefix/Suffix Symbolology ID or Record
Suffix . All of the above programmable parameters perform the same function depending on your setting.
Regarding the “ Bar Code Selection ” and “ Position Calculation ” of data formatter, please refer to page 60 for details.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
57
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Verifier Control
P.C
SS
MS
MS
Condensed DataWizard
♦
Data Verifier Setting
♦
Parameter Selection
Disable
Select one bar code symbology
Select all bar code symbologies
F_DEFAULT
Option Code 2nd Option Code
FIN
(2 digits)
00 automatic termination automatic termination
Identified Data Length
1st Identified Character
SS
MS
SS
DS
Disable
Enable
Determine the identified data length for verification.
Disable
Enable
2-digits checking position; 1 identified character
Disable
Enable
2-digits checking position; 1 identified character
FIN
(2 digits)
FIN
(2 digits) position
[00-7F]
2nd Identified Character
SS
DS
FIN
(2 digits) position
[00-7F]
3rd Identified Character
SS
DS
Disable
Enable
2-digits checking position; 1 identified character
FIN
(2 digits) position
[00-7F]
The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter .
All data must conform to the Identified Bar Code Symbologies , Identified Data Length , and one to three Identified Characters in the checking position. Otherwise, the
FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.
The Data Verifier checks only scanned data without Preamble , Postamble , STX , ETX , Data Length , Prefix/Suffix Symbology ID or Record Suffix .
Regarding the “ Bar Code Selection ” and “ Position Calculation ” of Data Verifier , please refer to page 60 for details.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
58
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Replacer Control
P.C
SS
MS
MS
Condensed DataWizard
♦
Data Replacer Setting
♦
Parameter Selection
Disable
Select one bar code symbology
Select all bar code symbologies
F_DEFAULT
Option Code 2nd Option Code
FIN
(2 digits)
00 automatic termination automatic termination
1st Replacement
2nd Replacement
SS
DS
SS
DS
Disable
Enable
2-digits identified position; 1 replacement character
Disable
Enable
2-digits identified position; 1 replacement character
FIN
(2 digits) position
FIN
(2 digits) position
[00-7F]
[00-7F]
3rd Replacement
SS
DS
Disable
Enable
2-digits identified position; 1 replacement character
FIN
(2 digits) position
[00-7F]
The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for replacer control, and provides Multiple Position Replcement in the identified position.
All data must conform to the Identified Bar Code Symbologies , and one to three Identified Characters in the identified position While the Data Replacer is enabled, it arranges only scanned data without Preamble , Postamble , STX , ETX , Data Length , Prefix/Suffix Symbology ID or Record Suffix .
Regarding the “ Bar Code Selection ” and “ Position Calculation ” of Data Replacer, please refer to page 60 for details.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table listed in Appendix to find mathced HEX value.
59
Configure Your FuzzyScan
PROGRAM
Family Code Selection
Organizer Control
Condensed DataWizard
♦
Data Organizer Setting
♦
P.C
SS
MS
MS
Parameter Selection
Disable
Select one bar code symbology
Select all bar code symbologies
F_DEFAULT
Option Code 2nd Option Code
FIN
(2 digits)
00 automatic termination automatic termination
1st Organization
Include/Exclude Control
2nd Organization
SS
DS
SS
DS
SS
DS
Disable
Enable
2-digits identified position;
Forward/backward data transmission setting
Disable
Enable
2-digits identified position;
Forward/backward data transmission setting
Transmitted data excluded the data of identified position
Transmitted data included the data of identified position
FIN
(2 digits) position direction
FIN
(2 digits) position direction
0
1
0 (Forward)
1 (Backward)
0 (Forward)
1 (Backward)
The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward . It also allows you to control the transmitted data including or excluding the data of identification position. Please refer to the application example listed in page 60 for details.
While the Data Organizer is enabled, it arranges only scanned data without Preamble , Postamble , STX , ETX , Data Length , Prefix/Suffix Symbology ID or Record
Suffix .
Regarding the “ Bar Code Selection ” and “ Position Calculation ” of Data Organizer, please refer to page 60 for details.
Please note that all “ Character ” input should be referred to the ASCII/HEX Table .
60
Configure Your FuzzyScan
You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the
FuzzyScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below.
Code 128 : 01
UCC/EAN 128 : 31
UPC-A : 02
UPC-A with 2 supple.: 32
UPC-A with 5 supple.: 42
UPC-E : 03
UPC-E with 2 supple.: 33
UPC-E with 5 supple.: 43
EAN-13 : 04
EAN-13 with 2 supple. : 34
EAN-13 with 5 supple. : 44
EAN-8 : 05
EAN-8 with 2 supple : 35
EAN-8 with 5 supple.: 45
Codabar/NW-7 : 06
Code 39 : 07
Code 32 : 37
Trioptic Code 39: 47
Matrix 2 of 5 : 38
Interleaved 2 of 5 : 48
China Postal Code : 58
German Postal Code : 68
Code 93 : 09
Code 11 : 10
MSI/Plessey : 11
UK/Plessey : 12
Telepen : 13
GS1 Data Bar : 14
IATA : 15
Coupon Code : 16
PDF417/MicroPDF417: 22
Codablock: 23
Korea Post Code: 26
[Data Formatter]
If there is a 5-character input data string, refer to the following to calculate the actual position for insertion:
00
X X X
01 02 03
X X
04 05
[Data Verifier, Data Replacer, Data Organizer]
If there is a 11-character data string, please refer to the following to calculate the actual position for identification.
X X X X X X X X X X X
00 01 02 03 04 05 06 07 08 09 10
If your bar code label is a 16-digit Interleaved 2 of 5 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price, you want the FuzzyScan do the following for you without software modification:
Apply only Interleaved 2 of 5 to the condensed
DataWizard.
Check bar code is actually with 16-digit length.
Allow bar code output whose date code is leading with
“9”.
Three outputs with “TAB” suffix.
The date code output should skip “9” and replaced it by
“A”.
The serial number output should be led with “SN”.
The unit price output should be skipped the first 2 digits.
Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6
Actual Output : A81025[TAB]SN123456[TAB]76[TAB]
61
[Data Verifier]
Scan “Program” to enter the programming mode.
Scan “Verifier Control” and set bar code symbology to “ 48 ”
(Interleaved 2 of 5).
Scan “Identified Data Length” and set the length to “ 16 ”.
Scan “1st Identified Character” and set the identified position to “ 00 ”, then set the identified character to “ 39 ”
(Hex Code of 9).
[Data Formatter]
Scan “Formatter Control” and set bar code symbology to
“ 48 ”.
Scan 1st Insertion” and set the identified position to “ 06 ”, then inserted characters to “ 09 ” (Hex Code of TAB), “ 53 ”
(Hex Code of S), “ 4E ” (Hex Code of N).
Scan “2nd Insertion” and set the identified position to “ 12 ”, then inserted character to “ 09 ”. In the final, you must scan
“ FIN ” (Finish) code to terminate this selection.
Scan “3rd Insertion” and set the identified position to “ 16 ”, then inserted character to “ 09 ”. In the final, you must scan
“ FIN ” (Finish) code to terminate this selection.
Configure Your FuzzyScan
[Data Replacer]
Scan “Replacer Control” and set bar code symbology to “ 48 ”.
Scan “1st Replacement” and set the identified position to “ 00 ”, then replaced character to “ 41 ” (Hex Code of
A).
[Data Organizer]
Scan “Organizer Control” and set bar code symbology to “ 48 ”.
Scan “1st Organization” and set the identified position to “ 16 ”, then set the data transmission to “ 0 ” (forward).
Scan “2nd Organization” and set the identified position to “ 17 ”, then set the data transmission to “ 1 ”
(backward).
Scan “ END ” (Exit) to terminate the programming.
[Important Notice]
Please note that Condensed DataWizard will follow the preset working flow as below:
Verifier Formatter Replacer Organizer
So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter.
62
Appendix
Symbology ID Table
Each AIM Code Identifier contains the three-character string ]cm where:
] = Flag Character c = Code Character m = Modifier Character
Cino ID AIM ID
Code Family
UPC
Code 128
Codabar
Primary Format
Code
Character
Code
Character
Modified
Character
UPC-A
UPC-A with 2 supple.
UPC-A with 5 supple.
UPC-E
A
E
UPC-E with 2 supple.
UPC-E with 5 supple.
E
Example: A UPC-A bar code 012345678950 with 2 supplement 12 is transmitted as ]E0 012345678950 ]E1 12
Code 128 B m
C
UCC/EAN-128
Codabar/NW-7
C
D F
1 m
1
2 m
1
2 m
Standard/Industrial 2 of 5
Matrix 2 of 5
Interleaved 2 of 5
I
K
J
S
X
I
0
0 m
Code 25
China Postal Code L X 0
IATA
German Postal Code
IATA
M
O
I
R
3 m
UCC Coupon Code Z
UCC Coupon
Example : A UPC-A 512345678900 + UCC/EAN-128 81010123451297 bar code is transmitted as ]E0 512345678900 ]C1 81010123451297
Example: A EAN-13 9923456789019 + UCC/EAN-128 81010123451297 bar code is transmitted as ]E0 9923456789019 ]C1 81010123451297
Cino ID AIM ID
Code Family Primary Format
EAN/JAN-8
EAN/JAN-8 with 2 supple.
EAN/JAN-8 with 5 supple.
EAN/JAN-13
Code
Character
N
Code
Character
E
EAN/JAN
EAN/JAN-13 with 2 supple.
EAN/JAN-13 with 5 supple.
F E 1
2
Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is transmitted as ]E4 49123562 ]E2 12345
Code 93 H G m Code 93
Code 11 Code 11
MSI/Plessey MSI/Plessey
P
R
H
M m m
S
T
P
B
0 m
UK/Plessey
Telepen
Code 39
UK/Plessey
Telepen
GS1 DataBar GS1 Databar
Compsoite Composite Code
Code 39
Code 39 Trioptic
PDF417
Codablock
Korea Post
Code 32
PDF417/Micro PDF417
Codablock F
Korea Post Code
X
G
W
G
V
Y a e
A
X
A
L
O
X
0 m
0
0
0
0
0
Modified
Character
4
1
2 m
Remark: Above examples are given for the transmission of AIM ID.
63
Appendix
Keyboard Function Code Table
03
04
05
06
No.
00
01
02
07
08
09
10
11
12
13
14
15
LF
VT
FF
CR
SO
SI
ANSI ASCII
NUL 00H
SOH
STX
01H
RESERVED
CTRL (Left)
02H ALT (Left)
Key Function
ETX
EOT
ENQ
ACK
03H
04H
05H
06H
SHIFT
CAPS LOCK
NUM LOCK
ESC
BEL
BS
HT
07H F1
08H BACK SPACE
09H TAB
0AH F2
0BH F3
0CH F4
0DH ENTER (CR)
0EH F5
0FH F6
29
30
31
25
26
27
28
19
20
21
22
No.
16
17
18
23
24
EM
SUB
ESC
FS
GS
RS
US
ANSI ASCII
DLE 10H F7
DC1
DC2
11H
12H
F8
F9
DC3
DC4
NAK
SYN
ETB
CAN
13H F10
14H F11
15H
16H
17H
18H
F12
Key Function
INS (Insert) (Edit)
DEL (Delete) (Edit)
HOME (Edit)
19H
1AH
1BH
1CH
1DH
1EH
1FH
END (Edit)
PAGE UP (Edit)
PAGE DOWN (Edit)
UP (Edit)
DOWN (Edit)
LEFT (Edit)
RIGHT (Edit)
To emulate the keyboard function key input for user definable parameters, user must configure actual content using the
Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP,
COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.
64
ASCII Input Shortcut
Appendix
To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the
“ HEX/ASCII Table ” for details.
Example:
If you want the scanned data output leading with a Dollar
Sign, you have to set the “Preamble” to “$”. The configuration procedure is listed below for reference.
Scan the system command – PROGRAM listed on page
3-24 to enter programming mode.
Scan family code – PREAMBLE to select this family.
Refer to the Hex/ASCII Table , you will find the HEX value of “ $ ” is 24 .
Scan the option code – 2 listed on the fold out back cover.
Scan the option code – 4 listed on the fold out back cover.
Scan the system command – FIN (Finish) to terminate
Preamble setting.
Scan the system command – End to exit the programming mode for normal operation.
HEX/ASCII Reference Table
9
A
B
6
7
8
H
L
0
1
2
3
4
5
C
D
E
F
0 1 2 3
FF
CR
SO
SI
NUL DLE SPACE 0
SOH DC1 ! 1
STX DC2
ETX DC3
EOT DC4
ENQ NAK
"
#
$
%
4
5
2
3
ACK SYN
BEL ETB
BS CAN
HT
LF
EM
SUB
VT ESC
&
'
(
)
*
+
9
:
;
6
7
8
FS
GS
RS
US
,
-
.
/
<
=
>
?
4
I
J
K
F
G
H
@
A
D
E
B
C
L
M
N
O
5 6
Example : ASCII “A”
→
HEX “41”; ASCII “a”
→
“61”
Y
Z
[
V
W
X
T
U
R
S
P
Q
\
]
^
_ i j k f g h d e b c
` a l m n o
7 y z
{ v w x t u r s p q
|
}
~
DEL
: High Byte of HEX Value
: Low Byte of HEX Value
65
Appendix
Link Mode Quick Set
Uninstall
HID Mode
Operation Mode Quick Set
Trigger Mode
PAIR Mode
PICO Mode
SPP Slave Mode
SPP Master Mode
Presentation Mode
66
Appendix
Host Interface Quick Set
(Work with Smart Cradle only)
RS232 Serial
USB HID Standard Mode
Keyboard Replacement
USB HID Turbo Mode
USB Com Port Emulation
PS/2 (DOS/V) KBW Standard Mode
PS/2 (DOS/V) KBW Turbo Mode
67
Option Codes
0
1
2
3
FIN (Finish)
7
6
5
4
Appendix
9
8
A
B
END (Exit)
F
E
D
C
68
Appendix
System Commands
PROGRAM
(Enter Programming Mode)
FIN (Finish)
Sleep
Paging
Save Configuration
Clone
END
(Exit Programming Mode)
PowerTool Host Link
Factory Default
System Information List
(SYSLIST)
Master Default
Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value (The radio link will be disconnected and the scanner will revert to uninstall state).
Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection , Keyboard Interface
Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), Wand/Laser Emulation Control ,
Bluetooth Device Name , Bluetooth PIN Code , and Out-of-range Scanning , the rest of parameters will be returned to default value (The radio link is still keep on).
Save User Default User Default
69
Appendix
Indications
Descriptions
Radio connected
Radio disconnected
During connection
Radio connection built
Radio connection lost
Data Transmission
Descriptions
Under charging (on cradle)
Fully charged (on cradle)
Under batch scanning
Pair failure
Out of memory
Battery power low
Battery power extremely low
Good read
Under Configuration
Uninstall state
Upgrade state
Time out warning
Paged by smart cradle
Sleep state / Battery no power
Link Indicator
Status Indicator
Link Indicator
1 blue blink per 2.5 sec.
3 blue blinks per 2 sec.
Quick blue blinks
1 blue blink per 2.5 sec.
3 blue blinks per 2 sec.
Quick blue blink
Steady red
Status Indicator
1 green blink at regular interval
1 green blink per 2.5 sec.
Steady red
2 red blinks
1 red blink at regular interval
8 red blinks
1 green blink
Steady red
Alternative red and green blinks
Steady red
Off
Off
Off
Beeper
Off
Off
Short clicks
4 beeps in ascending tone
4 beeps in descending tone
Short clicks
Beeper
Off
Off
Off
2 Di-do Di-do beeps
2 long beeps
1 beep at regular interval
8 beeps
1 good read beep
Off
Off
Short click
3 long beeps
6 page beeps
Off
70
Appendix
Center Indicator
Side Indicators
HB2100 Charging Cradle Indication
Descriptions
Power on Steady blue
Power
Off
Beeper
HB2110 Smart Cradle Indications
Power on
Smart Cradle Upgrade State
Uninstall state
PICO Mode
Descriptions
Center
1 blue blink
Off
Off
Radio Connected Steady blue
Radio Disconnected Off
PAIR Mode
Smart cradle paged by scanner
Radio Connected Steady blue
Radio Disconnected Off
PICO Mode
PAIR Mode
Steady blue
Steady blue
Indicators
Side
Off
Beeper
Steady red
Power on beeps
Short clicks
Alternative red-green blinks Off
Steady Green
Steady red
Off
Off
Off
Steady red
Steady green
Off
Off
Off
6 page beeps
6 page beeps
71
FuzzyScan Wireless Reference Manual
CINO GROUP
PC WORTH INT’L CO., LTD.
www.cino.com.tw

Public link updated
The public link to your chat has been updated.