1
GET TO KNOW
LUXEPORT
WALLSTATION
2
Turn off power to eliminate risk of shock during installation.
6) .5 ft/15 cm USB A -
USB C Cable
3
4 7) Lock Tool & Hardware
5
2
1) WallStation
2) Wall Box
3) iPort PoE Splitter (inside)
4) Charge Pins
5) Retention Ring
Tools Required:
• 2 3/4” (70mm) Hole Saw
• Electric Drill
• Phillips Screw Driver
INSTALLATION OVERVIEW
Provided in this manual are details on the 4 most common install scenarios in North America.
For a more detailed install matrix including Europe and the United Kingdom please visit
www.iportproducts.com/luxeport-support
3
4
NEW CONSTRUCTION
INSTALLATION OVERVIEW
Details: Page 12
Before After
Stud Bay
CAT5/6
WHAT YOU NEED
Required Components:
• LuxePort WallStation
71003 - Black
71004 - Silver
71005 - White
Power Requirements:
• POE Splitter (Included)
• POE Switch (802.3af) or POE Injector (if not using a
POE Switch) - 70719 (Sold Separately)
Wire Requirements:
• Cat5/6
5
6
RETROFIT
INSTALLATION OVERVIEW
Details: Page 14
Before After
Existing Wall
2 3/4”(70mm)
Hole Saw
WHAT YOU NEED
Required Components:
• LuxePort WallStation
71003 - Black
71004 - Silver
71005 - White
Power Requirements:
• POE Splitter (Included)
• POE Switch (802.3af) or POE Injector (if not using a
POE Switch) - 70719 (Sold Separately)
Wire Requirements:
• Cat5/6
7
8
SINGLE GANG
INSTALLATION OVERVIEW
Details: Page 22
Before After
1G
Wall Box
CAT5/6
WHAT YOU NEED
Required Components:
• LuxePort WallStation
71003 - Black
71004 - Silver
71005 - White
Wire Requirements:
1) Cat5/6
• LuxePort Wall Adapter Kit (Sold Separately)
71006 - Black
71007 - Silver
71008 - White
Power Requirements:
• POE Splitter (Included)
• POE Switch (802.3af) or POE Injector (if not using a
POE Switch) - 70719 (Sold Separately)
9
10
LAUNCHPORT WALLSTATION
UPGRADE OVERVIEW
Details: Page 29
Before After
WHAT YOU NEED
Required Components:
• LuxePort WallStation
71003 - Black
71004 - Silver
71005 - White
Wire Requirements:
• Existing 2 Conductor wire
OR
• CAT5/6 (if using PoE)
• LuxePort Wall Adapter Kit (Sold Separately)
71006 - Black
71007 - Silver
71008 - White
Power Requirements:
• POE Splitter (Included)
• 24V 1A Power Supply with 5.5 mm x 2.5mm barrel connector (Sold Separately)
OR
• 802.3af PoE Switch or iPort Injector (70719)
11
12
NEW CONSTRUCTION
INSTALLATION DETAILS
Step 1
Run new cat5/6 to the location the Luxeport
Wallstation will be installed when the wall is completed.
Loosely secure the Cat5/6 wire to the stud for easy retrieval.
CAT5/6
Prior to drywall, make sure to leave enough wire to work with when the wall is complete.
Step 2
Measure and note the location of the stud bay the cat5/6 wire is secured to for easy retrieval after drywall is installed.
Continue to the next page for installation of the
LuxePort Wall Box.
13
INSTALLING LUXEPORT
WALL BOX / RETROFIT INSTALL
Step 1
Use a Stud Finder to determine an unobstructed location to mount LuxePort
WallStation. Use a 2-3/4”
(70mm) Hole Saw and cut a hole in the desired location on the Wall.
14
The next steps are for drywall installation only. Discard the Retention Ring if installing in a solid surface such as wood or concrete.
Step 2
Use a wire fishing tool and run new CAT5/6 cable to power source location. Or pull wire through the wall from a previous run prior to drywall.
Step 3
Insert the LuxePort
Retention Ring in the wall as shown. Starting with the split end, insert one side of the ring into the 2-3/4” hole and rotate counter clockwise until the ring is all the way behind the drywall.
15
INSTALLING LUXEPORT
WALL BOX / RETROFIT INSTALL
Step 4
Position fins horizontally and bend out and around the wall.
Fins
16
CAUTION: Hold onto ring so it does not fall into the wall until secured by the tabs bent around the drywall.
CAT5/6
INSTALLING LUXEPORT
WALL BOX & RETENTION RING
Step 5
Insert the LuxePort Wall
Box and align the notches of the Wall Box with the tabs of the Retention Ring.
Level the Wall Box and rotate the Retention Ring as needed to level.
Step 6
Insert two fingers through the Wall Box to support the
Retention Ring in each corner and drive in the provided mounting screws until the Wall Box and
Retention Ring are both snug against the wall.
Hold
* Inside of wall
CAUTION: watch fingers when drilling.
17
18
INSTALLING LUXEPORT
WALL BOX & RETENTION RING
Step 7
Repeat drilling of the screws for the remaining 3 corners of the Wall Box.
Step 8
Once mounting is complete, bend the two exposed
Retention Ring Tabs until they brake off cleanly.
Note: Tabs must not protrude beyond the legnth of the Wall
Box for the LuxePort Wall
Station to sit flush on the wall.
Trim the tabs as needed.
19
INSTALLING PoE SPLITTER
AND WALLSTATION
Step 9
Connect the Cat5/6 cable to the RJ45 jack on the splitter.
Connect the USB cable to the splitter and the other end to the WallStation. Place the
Splitter into the Wall Box.
Step 10
20
Place WallStation against wall.
Orient Charge Pins downward.
Use the provided lock tool to attach the WallStation to the
Wall Box and secure all four mounting screws making sure to turn COUNTER CLOCKWISE until completely snug.
POWERING LUXEPORT
WALLSTATION
Option 1 | PoE
LuxePort WallStation can be powered by any
802.3af PoE Switch.
(Sold Separately)
Switch
Option 2 | Injector
LuxePort WallStation can be powered by the iPort PoE Injector.
(Sold Separately)
Part Number: 70719
21
22
SINGLE GANG
INSTALLATION DETAILS
Step 1
Remove 1G box from drywall.
Step 2
Run CAT5/6 Cable to power source location.
1 G Box
Step 3
Place the metal mounting plate on the wall. Using a pen or pencil, mark the anchor location on each of the four corners of the mounting plate.
Step 4
Drive the four provided wall anchors into the wall in the marked locations.
23
24
SINGLE GANG
INSTALLATION DETAILS
Step 5
Attach black metal mounting plate to the installed anchors using the provided mounting screws.
Step 6
Insert the LuxePort Wall Box into the Cover Plate.
Step 7
Place both the Wall Box and Cover Plate onto the
Mounting Plate and secure using the provided four M4 x 5.5 mm machine screws.
Continue to the next page for power information.
25
INSTALLING PoE SPLITTER
AND WALLSTATION
Step 8
Connect the Cat5/6 cable to the RJ45 jack on the splitter.
Connect the USB cable to the splitter and the other end to the WallStation. Place the
Splitter into the Wall Box.
Step 9
26
Place WallStation against wall.
Orient Charge Pins downward.
Use the provided lock tool to attach the WallStation to the
Wall Box and secure all four mounting screws making sure to turn COUNTER CLOCKWISE until completely snug.
POWERING LUXEPORT
WALLSTATION
Option 1 | PoE
LuxePort WallStation can be powered by any 802.3af PoE
Switch. (Sold Separately)
Switch
Option 2 | Injector
LuxePort WallStation can be powered by the iPort PoE Injector.
(Sold Separately)
Part Number: 70719
27
28
UPGRADING LAUNCHPORT
TO LUXEPORT
Step 1
Remove LaunchPort Cover
Plate and unscrew
LaunchPort WallStation.
Step 2
Leave existing drywall anchors installed.
Remove WallStation and secure 2 conductor wire from falling into the wall.
Remove old green connector using a 1.5 mm slotted screw driver.
29
30
LAUNCHPORT UPGRADE
OPTION 1 | 24V
110/220V Input
24V 1A Output
Using existing 2-wire used by LaunchPort to power a
LuxePort WallStation:
Source a 24V 1A DC power supply (not provided).
Connect the Power Supply to the receptacle and the cable to the existing
LaunchPort Power Wall Plate.
24V
1A
DC Connector:
2.5mm x 5.5mm
Terminate the 2-wire into the
Blue 2-pin connector on the
PoE Splitter using a precision slotted screwdriver.
LAUNCHPORT UPGRADE
POWER OPTION 2 | PoE
LuxePort can be powered by any 802.3af PoE Switch or iPort PoE injector
(sold separately).
iPort PoE
Injector
PN: 70719
Run new CAT 5/6 cable to power the LuxePort
WallStation. Connect the
CAT 5/6 cable into the
RJ-45 Jack on the
PoE Splitter.
31
32
UPGRADING LAUNCHPORT
TO LUXEPORT
Step 3
Attach black metal mounting plate to the installed anchors.
Step 5
Place both the Wall Box and Cover Plate onto the
Mounting Plate and secure using provided four M4 x
5.5 mm machine screws.
Step 4
Insert the LuxePort Wall Box into the Cover Plate.
33
34
INSTALLING PoE SPLITTER
AND WALLSTATION
Step 6
Connect the 2 conductor wire to the blue 2 pin connector (fig. 1) or connect the CAT5/6 cable to the RJ45 Jack
(fig. 2) on the splitter.
Connect the USB cable to the Splitter and the other end to the WallStation.
Place the Splitter into the Wall Box.
Figure 1
24V Power Option
Figure 2
PoE Option
35
36
Step 7
Place WallStation against wall.
Orient Charge Pins downward.
Use the provided lock tool to attach the WallStation to the
Wall Box and secure all four mounting screws making sure to turn COUNTER CLOCKWISE until completely snug.
ATTACHING LUXEPORT CASE
TO WALLSTATION
Place the Case in Portrait or
Landscape. Align the square recess of the case with the
WallStation and ensure the
Case is properly seated for secure mounting and charging.
Case can be charged in portrait or landscape on both the WallStation and BaseStation.
Dismount Case by pulling from left or right side.
37
For more help and info please visit: iportproducts.com/luxeport
CAUTION:
This product contains magnets. Do not place in direct proximity with magnetically sensitive objects such as credit cards or exposed hard drives. Persons with pace makers are not recommended to use this product.
iPort
991 Calle Amanacer
San Clemente, CA 92673
United States of America
+1 949 226 5222
CAUTION:
Use products as directed.
Unspecified use could result in injury.
Warranty can be found at iportproducts.com/warranty