BFT THALIA P Installation Manual
Below you will find brief information for THALIA P, ELI 250 BT, PHOBOS BT, IGEA BT, LUX G BT, LUX BT and SUB BT. This manual provides instructions for installing the THALIA P control panel, including tube arrangement, connections for accessories such as photocells and safety devices, limit switch/encoder inputs, and power supply details. It covers quick installation steps and simplified menu options for various gate motor types and operational settings.
Advertisement
Advertisement
8
0 2 7 9 0 8 3 8 7 5 7 8
QUADRO COMANDO
CONTROL PANEL
CENTRALE DE COMMANDE
SELBSTÜBERWACHENDE STEUERUNg
CUADRO DE MANDOS
BEDIENINgSPANEEL
www.torautomatic.hr
Attenzione! Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur! Achtung! Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! Let op! Lees de “Waarschuwingen” aan de binnenkant zorgvuldig!
I
NSTALLAZIONE VELOCE-QUICK INSTALLATION-INSTALLATION RAPIDE
SCHNELLINSTALLATION-INSTALACIÓN RÁPIDA - SNELLE INSTALLATIE
PREDISPOSIZIONE TUBI, TUBE ARRANGEMENT,
PRÉDISPOSITION DES TUYAUX, VORBEREITUNG DER LEITUNGEN,
DISPOSICIÓN DE TUBOS, VOORBEREIDING LEIDINGEN.
A
220
B
2x0,75
mm
2
mm
2
5x0,75
3x2,5
mm
2 *
0,75
0,75
* Vedere specifica motore
See motor specifications
Consultez les caractéristiques du moteur
Siehe Motordaten
Véase especificaciones motor
Zie motorspecificatie
5x0,75
mm
2
3x2,5
mm
2 *
125
JP21
24V
8888
C
SHIELD
ANT
Antenna
Antenne
Antena
Antenne
Connettore programmatore palmare,
Palmtop programmer connector,
Connecteur programmateur de poche,
Steckverbinder Palmtop-Programmierer,
Conector del programador de bolsillo,
Connector programmeerbare palmtop.
24V
220
230V
(*)
70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85
* Altre tensioni disponibili a richiesta
Other voltages available on request
Autres tensions disponibles sur demande
Weitere Spannungen auf Anfrage erhältlich
Otras tensiones disponibles a petición
Andere spanningen op aanvraag beschikbaar
L N 10 11 14 15 20 21 22 23 24 25 26 27 28 29 40 41 42 43 44 45 50 51 52 60 61 62 63 64 65
Display + tasti programmazione
Display + programming keys
Display + Programmierungstasten
Pantalla + botones programación
Display + programmeringstoetsen
Optional board connector
Connecteur carte facultative
Steckverbinder Zusatzkarte
Connector optionele kaart
L N 10 11 14 15 20 21 22 23 24 25 26 27 28 29 40 41 42 43 44 45
220
230V
L N
*
M1
M2
Alimentazione
Power supply
Alimentation
Stromversorgung
Alimentación /Voeding
Motore / Motor moteur/Motor
Eindaanslag/Motor
AUX
12/24V Ingressi finecorsa/encoder
Encoder/limit switch inputs
Entrées des fins de course /encodeur
Eingänge Anschlag/Encoder
Entradas finales de carrera
Encoder/ingangen
50 51 52 60 61 62 63 64 65 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85
AUX 3 = 5
AUX 3 = 6
26 27 26 27
AUX 3 = 1
1
50 51
Collegamento di 1 coppia di fotocellule non verificate,
Connection of 1 pair of non-tested photocells,
Connexion 1 paire photocellules no vérifiées,
Anschluss von einem Paar nicht überprüften Fotozellen,
Conexión de 1 par fotocélulas no comprobadas,
Aansluiting van 1 paar fotocellen anders dan “trusted device”.
D
SAFE 1 = 0
50 51 70 72
1
2
TX1 RX1
1
2
3
4
5
2 THALIA P
inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
0 ( int )
ELI 250 BT tipo otore - type de oteur - otorentyp - otor type - tipo otor:
1 E
M2 M1 M1 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 ( ext )
M2
10 11 14 15
M1 M2
40 41 42 43 44 45
M1
M2
M1
M2 M2 M1 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
0 ( int )
PHOBOS BT tipo otore - type de oteur - otorentyp - otor type - tipo otor:
2
10 11 14 15 40 41 42 43 44 45
M2 M1 M1 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 ( ext )
M1 M2
M1
1 2 3
M2
1 2 3
M2 M2 M1 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
0 ( int )
IGEA BT tipo otore - type de oteur - otorentyp - otor type - tipo otor:
3
10 11 14 15 40 41 42 43 44 45
M2 M1 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 ( ext )
M1 M2
M1
1 2 3
M2
1 2 3
M1 M2
THALIA P 3
M2
M1
M2
M1 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
0 ( int
)
LUX BT tipo motore - type de moteur - motorentyp - motor type - tipo motor:
4
LUX G BT tipo motore - type de moteur - motorentyp - motor type - tipo motor:
5
E
10 11 14 15 40 41 42 43 44 45
M1 M1 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 ( ext )
M2
M1 M2
M1 M2 reg. fc. - l.sg adj - regl.fc - endsche inst
M2 M2 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
0 ( int )
M1
1 2
SUB BT tipo motore - type de moteur - motorentyp - motor type - tipo motor:
6
10 11 14 15 40 41 42 43 44 45
M1 M1 inv.direz. ap / open in other direct.
inv.sens.ouv / inv richt offnung inv.direcc.ap./ Omkering openingsrichting:
1 ( ext )
M2
M1 M2
M2 M2 M1
*Bianco
**Rosso
***Nero
*Bianco
White
Blanc
Weiß
Blanco
Wit
**Rosso
Red
Rouge
Rot
Rojo
Rood
***Nero
Black
Noir
Nero
Negro
Zwart
4 THALIA P
lang x1 tipo n. mot.
Dir preset
LUX BT / LUX G BT reg. fc.
autoset
MENU SEMPLIFICATO int
EXT
AR sr ac sc ind eli phob igea
.....
2
1
ITA fra deu eng esp
INT : apertura verso l’interno
EXT : apertura verso l’esterno ar : funzionamento automatico, residenziale sr : funzionamento semi-aut., residenziale ac : funzionamento automatico, condominiale
Sc : funzionamento semi-automatico, condominiale
Ind : funzionamento a uomo presente o
ELI BT / PHOBOS BT / IGEA BT / SUB BT
2
2
2
2 opm1
1
: regolazione finecorsa
di apertura motore 1 opm2 clm2 clm1 ersu o o
1
1
1
: regolazione finecorsa
di apertura motore 2
: regolazione finecorsa
di chiusura motore 2
-
: regolazione finecorsa
di chiusura motore 1 fine
. . . . . .
MIN 1 - MAX 3
AUTO OPEN AUTO CLOSE
o rilascia
tasto desiderato
O 01 mem.telec
fine tasto nascosto
THALIA P 5
6 THALIA P
PRESET
PARAMETRI
Tempo ritardo apertura motore 2 [s]
Tempo di ritardo chiusura motore 1 [s]
Tempo chiusura automatica [s]
Tempo sgombero zona semaforica [s]
Spazio di rallentamento in apertura [%]
Spazio di rallentamento in chiusura [%]
Spazio di decelerazione [%]
Forza anta/e in apertura [%]
Forza anta/e in chiusura [%]
Velocità in apertura [%]
Velocità in chiusura [%]
Velocità rallentamento [%]
LOGICHE
Tipo motore
Tempo Chiusura Automatica
Chiusura rapida
Movimento passo passo
Preallarme
Uomo presente
Blocca impulsi in apertura
Blocca impulsi in TCA
Blocca impulsi in chiusura
Colpo di ariete in apertura
Colpo di ariete in chiusura
Mantenimento blocco
Pressione finecorsa chiusura
ICE
1 motore attivo
Inversione direzione di apertura
SAFE 1
SAFE 2
SAFE 3
SAFE 4
SAFE 5
SAFE 6
IC 1
IC 2
IC 3
IC 4
AUX 1
AUX 2
AUX 3
Tipo serratura
Codice Fisso
Programmazione radiocomandi
Modo seriale
Indirizzo
EXPI1
EXPI2
EXPO1
EXPO2
Prelampeggio semaforo
Semaforo rosso fisso
DEFAULT
ar sr ac sc ind
0
1
0
0
0
0
1
0
3
3
4
2
6
0
2
4
0
9
9
1
0
0
0
0
6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
10
10
15
50
3
3
10
40
50
99
99
25
0
0
0
/
0
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
0
/
/
/
/
0
0
0
0
0
0
0
0
1
0
/
0
0
10
10
15
50
10
40
3
3
50
99
99
25
0
1
0
/
0
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
0
/
/
/
/
0
0
0
0
0
0
0
1
0
1
/
0
0
10
10
15
50
10
40
3
3
50
99
99
25
1
1
0
/
0
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
0
/
/
/
/
0
0
0
0
0
0
0
1
0
1
/
1
0
10
10
15
50
10
40
3
3
50
99
99
25
0
1
0
/
0
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
0
/
/
/
/
0
0
0
0
0
0
0
0
0
0
/
0
0
10
10
15
50
3
3
10
40
50
99
99
25
1
1
0
/
0
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
0
/
/
/
/
0
0
0
0
0
0
0
0
0
0
/
1
0
10
10
15
50
10
40
3
3
50
99
99
25
x1 language type n. mot.
Dir preset
LUX BT / LUX G BT l.sw adj autoset
SIMPLIFIED MENU eli phob igea
.....
2
1
ITA fra deu eng esp int
EXT
AR sr ac sc ind
Scroll up
Scroll down
Exit Menù
INT
: inward opening
EXT
: outward opening ar : automatic operation, residential sr : semiautomatic operation, residential ac : automatic operation, commercial
Sc : semiautomatic operation, commercial
Ind : dead man operation o
ELI BT / PHOBOS BT / IGEA BT / SUB BT
2
2
2
2 opm1
1
: motor 1 opening
limit switch adjustment opm2 clm2 clm1 ersu o o
1
1
1
: motor 2 opening
limit switch adjustment
: motor 2 closing
limit switch adjustment
-
: motor 1 closing
limit switch adjustment end
. . . . . .
MIN 1 - MAX 3
AUTO OPEN AUTO CLOSE
o release desidered button O 01 mem.remotes
end hidden button
THALIA P 7
8 THALIA P
PRESET
PARAMETERS
Motor 2 opening delay time [s]
Motor 1 closing delay time [s]
Automatic closing time [s]
Time-to-clear traffic light zone [s]
Slow-down distance during opening [%]
Slow-down distance during closing [%]
Deceleration distance [%]
Leaf force during opening [%]
Leaf force during closing [%]
Opening speed [%}
Closing speed [%]
Slow-down speed [%]
LOGIC
Motor type
Automatic Closing Time
Fast closing
Step-by-step movement
Pre-alarm
Deadman
Block pulses during opening
Block pulses during TCA
Block pulses during closing
Hammer during opening
Hammer during closing
Stop maintenance
Closing limit switch pressure
ICE feature
1 motor active
Open in other direction
SAFE 1
SAFE 2
SAFE 3
SAFE 4
SAFE 5
SAFE 6
IC 1
IC 2
IC 3
IC 4
AUX 1
AUX 2
AUX 3
Type of lock.
Fixed code
Transmitter programming
Serial mode
Address
EXPI1
EXPI2
EXPO1
EXPO2
Traffic light pre-flashing
Steadily lit red light ac
3
10
15
50
50
3
10
40
10
99
99
25
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
0
0
0
0
0
0
0
1
1
1
/
1
0
/
/
/
0
0
0
1
/
0
0 sr
3
10
15
50
50
3
10
40
10
99
99
25
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
0
0
0
0
0
0
0
0
0
0
/
0
0
/
/
/
0
0
0
1
/
0
0
DEFAULT
ar
3
10
15
50
50
3
10
40
10
99
99
25
3
10
15
50
50
3
10
40
10
99
99
25
0
0
3
1
2
3
0
4
0
6
2
4
0
0
6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
9
0
0
0
1
9
0
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
0
0
0
0
0
0
0
0
1
0
/
1
0
/
/
/
0
0
0
1
/
0
0 sc ind
3
10
15
50
50
3
10
40
10
99
99
25
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
0
0
0
0
0
0
0
1
0
1
/
0
0
/
/
/
0
0
0
1
/
0
0
3
10
15
50
50
3
10
40
10
99
99
25
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
0
0
0
0
0
0
1
0
0
0
/
0
0
/
/
/
0
0
0
0
/
0
0
lang x1 type n. mot.
Dir preset
LUX BT / LUX G BT regL. fc.
autoset
MENU SIMPLIFIÉ eli phob igea
.....
2
1
ITA fra deu eng esp int
EXT
AR sr ac sc ind
Monter
Descendre
Confirmation / allumage afficheur
Sortir du menu
INT : ouverture vers l’intérieur
EXT : ouverture vers l’extérieur ar : fonctionnement automatique, résidentiel sr : fonctionnement semi-automatique, résidentiel ac : fonctionnement automatique, collectif
Sc : fonctionnement semi-automatique, collectif
Ind : fonctionnement à homme présent o
ELI BT / PHOBOS BT / IGEA BT / SUB BT
2
2
2
2 opm1
1
: réglage fin de course d’ouverture moteur 1 opm2 clm2 clm1 ersu o o
1
1
1
: réglage fin de course d’ouverture moteur 2
: réglage fin de course de fermeture moteur 2
-
: réglage fin de course de fermeture moteur 1 fin
. . . . . .
MIN 1 - MAX 3
AUTO OPEN AUTO CLOSE
o relacher touche desiree O 01 mem.telec
fin touche cachee
THALIA P 9
10 THALIA P
PRESET
PARAMETRES
Temps retard ouverture moteur 2 [s]
Temps de retard fermeture moteur 1 [s]
Temps fermeture automatique [s]
Temps évacuation zone du sémaphore [s]
Espace de ralentissement à l'ouverture [%]
Espace de ralentissement à la fermeture [%]
Espace de décélération [%]
Force vantail/vantaux à l'ouverture [%]
Force vantail/vantaux à la fermeture [%]
Vitesse à l'ouverture [%]
Vitesse à la fermeture [%]
Vitesse ralentissement [%]
LOGIQUES
Type moteur
Temps fermeture automatique
Fermeture rapide
Mouvement pas à pas
Préalarme
Homme-présent
Verrouillage impulsions à l’ouverture
Verrouillage impulsions en TCA.
Verrouillage impulsions à la fermeture
Coup de bélier à l’ouverture
Coup de bélier à la fermeture
Maintien verrouillage
Pression fin de course fermeture
ICE
1 Moteur actif
Inversion direction de l’ouverture
SAFE 1
SAFE 2
SAFE 3
SAFE 4
SAFE 5
SAFE 6
IC 1
IC 2
IC 3
IC 4
AUX 1
AUX 2
AUX 3
Type de serrure
Code fixe
Programmation radiocommande
Mode série
Adresse
EXPI1
EXPI2
EXPO1
EXPO2
Pré-clignotement sémaphore
Sémaphore rouge fixe sr
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
0
0
0
0
/
0
0
DEFAULT
ar
10
10
15
50
10
40
3
3
50
99
99
25
0
0
1
0
2
3
3
0
4
0
6
2
4
0
6
9
0
0
9
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
0
1
0
0
/
1
0
10
10
15
50
3
3
10
40
50
99
99
25 ac
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
1
1
1
0
/
1
0 sc ind
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
1
0
1
0
/
0
0
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
0
0
/
/
0
0
0
0
0
0
1
0
0
0
0
/
0
0
lang x1 type n. mot.
Dir preset
LUX BT / LUX G BT endsch. eINST autoset
VEREINFACHTES MENÜ int
EXT
AR sr ac sc ind eli phob igea
.....
2
1
ITA fra deu eng esp
Aufwärts
Abwärts
Bestätigung/
Aufleuchten Display
Zurück zum
Hauptmenü
INT : Öffnung nach innen
EXT : Öffnung nach außen ar : Automatikbetrieb, Wohnbereich sr : Halbautomatikbetrieb, Wohnbereich ac : Automatikbetrieb, Hausbereich
Sc : Halbautomatikbetrieb, Hausbereich
Ind : Halbautomatikbetrieb, Hausbereich o
ELI BT / PHOBOS BT / IGEA BT / SUB BT
2
2
2
2 opm1
1
: Einstellung Endschalter
Öffnung Motor 1 opm2 clm2 clm1
1
1
1
: Einstellung Endschalter
Öffnung Motor 2
-
: Einstellung Endschalter
Schließung Motor2
-
: Einstellung Endschalter
Schließung Motor2 ersu o o ende
. . . . . .
MIN 1 - MAX 3
AUTO OPEN AUTO CLOSE
o loslassen gevue. taste O 01 speichern hs ende verst. taste
THALIA P 11
12 THALIA P
PRESET
PARAMETER
Verzögerungszeit Öffnung Motor 2 [s]
Verzögerungszeit Schließung Motor 1 [s]
Zeit automatische Schließung [s]
Räumungszeit Ampelbereich [s]
Verlangsamungsraum Öffnung [%]
Verlangsamungsraum Schließung [%]
Verlangsamungsraum [%]
Kraft Flügel bei Öffnung [%]
Kraft Flügel bei Schließung [%] geschwindigkeit Öffnung [%] geschwindigkeit Schließung [%] geschwindigkeit Verlangsamung [%]
LOGIK
Motortyp
Zeit automatische Schließung
Schnelle Schließung
Bewegung Schritt Schritt
Voralarm
Mann anwesend
Blockiert Öffnungsimpulse
Blockiert TCA-Impulse
Blockieren Impulse Schließen
Widderschlag Öffnung
Widderschlag Schließung
Halten Blockierung
Drücken Endschalter Schließung
ICE
1 Motor aktiv
Richtungsumkehrung Öffnung
SAFE 1
SAFE 2
SAFE 3
SAFE 4
SAFE 5
SAFE 6
IC 1
IC 2
IC 3
IC 4
AUX 1
AUX 2
AUX 3
Typ Schloss
Fester Code
Programmierung Fernbedienungen
Serieller Modus
Adresse
EXPI1
EXPI2
EXPO1
EXPO2
Vorblinken Ampel
Ampel dauerhaft rot sr
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
0
0
0
0
/
0
0
DEFAULT
ar
10
10
15
50
10
40
3
3
50
99
99
25
0
0
1
0
2
3
3
0
4
0
6
2
4
0
6
9
0
0
9
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
0
1
0
0
/
1
0
10
10
15
50
3
3
10
40
50
99
99
25 ac
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
1
1
1
0
/
1
0 sc ind
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
1
0
1
0
/
0
0
10
10
15
50
10
40
3
3
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
0
0
/
/
0
0
0
0
0
0
1
0
0
0
0
/
0
0
lang x1
TIPO n. mot.
Dir preset
LUX BT / LUX G BT reg. fc.
autoset
MENÚ SEMPLIFICADO eli phob igea
.....
2
1
ITA fra deu eng esp int
EXT
AR sr ac sc ind
LEYENDA
Desplazar hacia arriba
Desplazar hacia abajo
Confirmación/
Encendido pantalla
Retorno al menú principal
INT : apertura hacia dentro
EXT : apertura hacia afuera ar : funcionamiento automático, en viviendas sr : funcionamiento semi-aut, en viviendas ac : funcionamiento automático, en edificios
Sc : funcionamiento semi-aut, en edificios
Ind : funcionamiento con hombre presente o
ELI BT / PHOBOS BT / IGEA BT / SUB BT
2
2
2
2 opm1
1
: regulación final de carrera
de apertura motor 1 opm2 clm2 clm1 ersu o o
1
1
1
: regulación final de carrera
de apertura motor 2
-
: regulación final de carrera
de cierre motor 2
-
: regulación final de carrera
de cierre motor 1 fin
. . . . . .
MIN 1 - MAX 3
AUTO OPEN AUTO CLOSE
o
RADIOM
FIN anad start suelte tecla deseada O 01
THALIA P 13
14 THALIA P
PRESET
PARÁMETROS
Tiempo retardo apertura motor 2 [s]
Tiempo de retardo cierre motor 1 [s]
Tiempo cierre automático [s]
Tiempo de evacuación zona semáforos [s]
Espacio de deceleración en fase de apertura [%]
Espacio de deceleración en fase de cierre [%]
Espacio de deceleración [%]
Fuerza hoja/s en fase de apertura [%]
Fuerza hoja/s en fase de cierre [%]
Velocidad en fase de apertura [%]
Velocidad en fase de cierre [%]
Velocidad deceleración [%]
LÓGICA
Tipo motor
Tiempo de Cierre Automático
Cierre rápido
Movimiento paso a paso
Prealarma
Hombre presente
Bloqueo impulsos en fase de apertura
Bloqueo impulsos en TCA
Bloquea impulsos en fase de cierre golpe de ariete en fase de apertura golpe de ariete en fase de cierre
Mantenimiento bloqueo
Presión final de carrera de cierre
ICE
1 motor activo
Inversión dirección de apertura
SAFE 1
SAFE 2
SAFE 3
SAFE 4
SAFE 5
SAFE 6
IC 1
IC 2
IC 3
IC 4
AUX 1
AUX 2
AUX 3
Tipo cerradura
Código Fijo
Programación de los radiomandos
Modo serial
Dirección
EXPI1
EXPI2
EXPO1
EXPO2
Preparpadeo semáforo
Semáforo rojo fijo
DEFAULT
ar
10
10
15
50
10
40
3
3
50
99
99
25
0
0
1
0
2
3
3
0
4
0
6
2
4
0
6
9
0
0
9
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
0
1
0
0
/
1
0
10
10
15
50
3
3
10
40
50
99
99
25 sr
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
0
0
0
0
/
0
0 ac
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
1
1
1
0
/
1
0 sc ind
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
1
0
1
0
/
0
0
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
0
0
/
/
0
0
0
0
0
0
1
0
0
0
0
/
0
0
lang x1 type n. mot.
Dir preset
LUX BT / LUX G BT l.sw adj autoset
VEREENVOUDIGD MENU eli phob igea
.....
2
1
ITA fra deu eng esp int
EXT
AR sr ac sc ind
INT
: opening naar binnen
EXT
: opening naar buiten ar
: automatische werking, residentieel sr
: semi-automatische werking, residentieel ac
: automatische werking, gemeenschappelijk
Sc
: semi-automatische werking, gemeenschappelijk
Ind
: werking bij aanwezige persoon o
ELI BT / PHOBOS BT / IGEA BT / SUB BT opm1
2
2
2
2
1 opm2 clm2 clm1
1
1
1
: afstelling aanslag voor
opening motor 2
-
: afstelling aanslag voor
sluiting motor 2
-
: afstelling aanslag voor
sluiting motor 1 ersu o o end
. . . . . .
MIN 1 - MAX 3
AUTO OPEN AUTO CLOSE
o
Doorloop op
Doorloop neer
Bevestig /
Aanschakeling display
Terugkeer naar het hoofdmenu release desidered button O 01 mem.remotes
end hidden button
THALIA P 15
16 THALIA P
PRESET
PARAMETER
Vertragingstijd opening motor 2 [sec]
Vertragingstijd sluiting motor 1 [sec.]
Tijd automatische sluiting [sec.]
Ontruimingstijd verkeerslichtzone [sec.]
Vertragingsruimte bij opening [%]
Vertragingsruimte bij sluiting [%]
Ruimte afremming [%]
Maximumkracht vleugel(s) bij opening [%]
Maximumkracht vleugel(s) bij sluiting [%]
Snelheid bij opening [%]
Snelheid bij sluiting [%]
Vertragingssnelheid [%]
LOGICA’S
Type motor
Tijd Automatische Sluiting
Snelle sluiting
Stap voor stap beweging
Vooralarm
Persoon aanwezig
Blokkeert impulsen bij opening
Blokkeert impulsen in TCA
Blokkeert impulsen bij sluiting
Drukstoot bij opening
Drukstoot bij sluiting
Handhaving blokkering
Druk aanslag sluiting
ICE
1 motor actief
Omkering openingsrichting
SAFE 1
SAFE 2
SAFE 3
SAFE 4
SAFE 5
SAFE 6
IC 1
IC 2
IC 3
IC 4
AUX 1
AUX 2
AUX 3
Type slot.
Vaste Code
Programmering afstandsbedieningen
Seriële modus
Adres
EXPI1
EXPI2
EXPO1
EXPO2
Vooraf knipperen stoplicht
Continu rood stoplicht sr
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
0
0
0
0
/
0
0
DEFAULT
ar
10
10
15
50
10
40
3
3
50
99
99
25
0
0
1
0
2
3
3
0
4
0
6
2
4
0
6
9
0
0
9
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
0
1
0
0
/
1
0
10
10
15
50
3
3
10
40
50
99
99
25 ac
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
1
1
1
0
/
1
0 sc ind
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
1
0
/
/
0
0
0
0
0
0
0
1
0
1
0
/
0
0
10
10
15
50
3
3
10
40
50
99
99
25
/
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
0
/
/
0
0
/
0
0
/
/
0
0
0
0
0
0
1
0
0
0
0
/
0
0
51 52 72 76 77 78 79 80 81 82 83 84 85
F
1
2
51
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 1
3
1
2
1
2
1
2
3
1
2
3
51
50
70
72
5
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
1
2
3
1
2
3
51
50
70
73
72
2 PHOT / 2 PHOT OP / 2 PHOT CL
52
50
1
2
1
2
52
50
1
2
1
2
51
50
70
72
51
50
73
70
3
4
5
1
2
3
4
1
2
5
3
4
5
1
2
3
4
1
2
5
5
70
72
SAFETY EDGE
BAR 8K2
SAFETY EDGE
52
70
73
50
51
51
72
70
50
51
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
52
72
73
70
50
51
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
52
72
70
50
51
2 BAR
4
3
2
1
6
5
4
3
6
5
2
1
4
3
2
1
6
5
4
3
6
5
2
1
8,2Kohm 5%
1
2
51
50
SAFE 3
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
1
2
3
1
2
3
51
50
76
77
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
1
2
3
1
2
3
51
50
76
78
77
52
50
52
50
2 PHOT / 2 PHOT OP / 2 PHOT CL
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
51
50
76
77
51
50
78
76
3
4
51
77
76
50
51
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
52
76
78
50
51
52
77
78
76
50
51
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
52
77
76
50
51
2 BAR
4
3
2
1
6
5
4
3
6
5
2
1
4
3
2
1
6
5
4
3
6
5
2
1
1
2
51
50
SAFE 5
1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 5
1
2
1
2
1
2
3
1
2
3
51
50
81
82
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
1
2
3
1
2
3
51
50
81
83
82
4
3
2 PHOT / 2 PHOT OP / 2 PHOT CL
52
50
1
2
1
2
52
50
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
51
50
81
82
51
50
83
81
51
82
81
50
51
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
52
81
83
50
51
52
82
83
81
50
51
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
52
82
81
50
51
2 BAR
4
3
2
1
6
5
4
3
6
5
2
1
4
3
2
1
6
5
4
3
6
5
2
1
1
2
5
51
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
1
2
3
1
2
3
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
1
2
3
1
2
3
52
50
52
50
70
74
2 PHOT / 2 PHOT OP / 2 PHOT CL
1
2
1
2
SAFETY EDGE
51
50
70
74
51
50
75
70
3
4
5
1
2
3
4
1
2
5
3
4
5
1
2
3
4
1
2
5
51
50
70
75
74
51
50
70
74
3
4
BAR 8K2
SAFETY EDGE
52
74
75
70
50
51
51
74
70
50
51
52
74
70
50
51
52
70
75
50
51
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
4
3
2
1
6
5
4
3
6
5
2
1
2 BAR
4
3
2
1
6
5
4
3
6
5
2
1
8,2Kohm 5%
2
1
51
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 4
3
1
2
1
2
1
2
3
1
2
3
51
50
76
79
4
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
1
2
3
1
2
3
51
50
76
80
79
2 PHOT / 2 PHOT OP / 2 PHOT CL
52
50
1
2
1
2
52
50
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
51
50
76
79
51
50
80
76
52
79
80
76
50
51
51
79
76
50
51
52
76
80
50
51
52
79
76
50
51
4
3
2
1
6
5
4
3
6
5
2
1
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
2 BAR
4
3
2
1
6
5
4
3
6
5
2
1
1
2
51
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
SAFE 6
3
1
2
1
2
1
2
3
1
2
3
51
50
81
84
4
52
50
1 PHOT / 1 PHOT OP / 1 PHOT CL
1
2
1
2
1
2
3
1
2
3
51
50
81
85
84
2 PHOT / 2 PHOT OP / 2 PHOT CL
52
50
1
2
1
2
52
50
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
51
50
81
84
51
50
85
81
52
81
85
50
51
52
84
81
50
51
51
84
81
50
51
52
84
85
81
50
51
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
1 BAR
4
3
2
1
6
5
4
3
6
5
2
1
4
3
2
1
6
5
4
3
6
5
2
1
2 BAR
4
3
2
1
6
5
4
3
6
5
2
1
THALIA P 17
x 2
ACCESS MENUS Fig. 1
See PARAMETERS MENU
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù
See LOGIC MENU add. start
Add. 2ch erase 64 hidden butt hidden butt release desired button release desired button
See RADIO MENU language autoset l.sw adj stat password opm1
SET
2 1 opm2
2
2
2 clm2 clm1 ersu o
1
1
1
-
-
+ / -
ER2x * vers OK
Control unit software version bft . . .
+ / -
- + n. cycles
- + n. remotes
- + err
OK 0000
+ / -
No radio control devices memorised
OK 00
+ / -
List of last 30 errors
OK
01.33
02.01
........
30.15
+ / -
0--10--
ER3x *
ER4x *
ER5x *
ER61
ER7x *
ERF9
Ersw
ER01
ER02
ER03
ER04 er06
ER1x *
STRE
STRI
OPEN
CLS
PED
TIME
STOP
PHOT
PHOP
PHCL
BAR
SWC1
SWO1
SWC2
SWO2
35.40
Instantaneous force motor 2
Instantaneous force motor 1
DESCRIPTION
START E external start input activated
START I internal start input activated
OPEN input activated
CLOSE input activated
PED pedestrian input activated
TIMER input activated
STOP input activated
PHOT photocell input activated
PHOT OP opening photocell input activated
PHOT CL closing photocell input activated
BAR safety edge input activated
SWC1 motor 1 closing limit switch input activated
SWO1 motor 1 opening limit switch input activated
SWC2 motor 2 closing limit switch input activated
SWO2 motor 2 opening limit switch input activated
The board is standing by to perform a complete openingclosing cycle uninterrupted by intermediate stops in order to acquire the torque required for movement.
WARNINg! Obstacle detection not active
Photocell test failed
Safety edge test failed
Opening photocell test failed
Closing photocell test failed
8k2 safety edge test failed
Board hardware test error
Encoder error
Reverse due to obstacle - Amperostop
Thermal cutout
Communication error with remote devices
Running off battery
Internal system supervision control error.
Solenoid lock output overload
Error during limit switch adjustment
* X = 0, 1, .., 9, A, B, C, D, E, F
NOTES
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
- C h e c k c o n n e c t i o n s t o m o t o r
- Hardware problems with board (contact technical assistance)
- M o t o r p o w e r o r e n c o d e r s i g n a l c a b l e s i n v e r t e d / d i s c o n n e c t e d .
- Actuator movement is too slow or stopped with respect to programmed operation.
Check for obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory devices and/or expansion boards
--
Try switching the board off and back on again.
If the problem persists, contact the technical assistance department.
- C h e c k l o c k c o n n e c t i o n s
- Unsuitable lock
- Repeat the limit switch adjustment procedure.
- Try moving the maximum limits of both the opening and closing limit switches.
- Caution: the last centimetre of the piston’s stroke, during either opening or closing, cannot be used.
1501520 prg
THALIA P 29
INSTALLER WARNINGS
WARNING! Important safety instructions. Carefully read and comply with all the warnings and instructions that come with the product as incorrect installation can cause injury to people and animals and damage to property.
The warnings and instructions give important information regarding safety, installation, use and maintenance. Keep hold of instructions so that you can attach them to the technical file and keep them handy for future reference.
GENERAL SAFETY
This product has been designed and built solely for the purpose indicated herein.
Uses other than those indicated herein might cause damage to the product and create a hazard.
- The units making up the machine and its installation must meet the requirements of the following European Directives, where applicable: 2004/108/EC, 2006/95/
EC, 2006/42/EC, 89/106/EC, 99/05/EC and later amendments. For all countries outside the EEC, it is advisable to comply with the standards mentioned, in addition to any national standards in force, to achieve a good level of safety.
- The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims all responsibility resulting from improper use or any use other than that for which the product has been designed, as indicated herein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.) and for deformation that could occur during use.
- Before installing the product, make all structural changes required to produce safety gaps and to provide protection from or isolate all crushing, shearing and dragging hazard areas and danger zones in general in accordance with the provisions of standards EN 12604 and 12453 or any local installation standards.
Check that the existing structure meets the necessary strength and stability requirements.
- Before commencing installation, check the product for damage.
- The Firm is not responsible for failure to apply Good Practice in the construction and maintenance of the doors, gates, etc. to be motorized, or for deformation that might occur during use.
- Make sure the stated temperature range is compatible with the site in which the automated system is due to be installed.
- Do not install this product in an explosive atmosphere: the presence of flammable fumes or gas constitutes a serious safety hazard.
- Disconnect the electricity supply before performing any work on the system.
Also disconnect buffer batteries, if any are connected.
- Before connecting the power supply, make sure the product’s ratings match the mains ratings and that a suitable residual current circuit breaker and overcurrent protection device have been installed upline from the electrical system. Have the automated system’s mains power supply fitted with a switch or omnipolar thermal-magnetic circuit breaker with a contact separation that meets code requirements.
- Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at no more than 0.03A as well as any other equipment required by code.
- Make sure the earth system has been installed correctly: earth all the metal parts belonging to the entry system (doors, gates, etc.) and all parts of the system featuring an earth terminal.
- Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453.
- Impact forces can be reduced by using deformable edges.
- In the event impact forces exceed the values laid down by the relevant standards, apply electro-sensitive or pressure-sensitive devices.
- Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and shearing hazards. Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the operating logic of the system and forces generated by the automated system.
- Apply all signs required by current code to identify hazardous areas (residual risks). All installations must be visibly identified in compliance with the provisions
- of standard EN 13241-1.
Once installation is complete, apply a nameplate featuring the door/gate’s data.
- This product cannot be installed on leaves incorporating doors (unless the motor can be activated only when the door is closed).
- If the automated system is installed at a height of less than 2.5 m or is accessible, the electrical and mechanical parts must be suitably protected.
- Install any fixed controls in a position where they will not cause a hazard, away from moving parts. More specifically, hold-to-run controls must be positioned within direct sight of the part being controlled and, unless they are key operated, must be installed at a height of at least 1.5 m and in a place where they cannot be reached by the public.
- Apply at least one warning light (flashing light) in a visible position, and also attach a Warning sign to the structure.
- Attach a label near the operating device, in a permanent fashion, with information on how to operate the automated system’s manual release.
- Make sure that, during operation, mechanical risks are avoided or relevant protective measures taken and, more specifically, that nothing can be banged, crushed, caught or cut between the part being operated and surrounding parts.
- Once installation is complete, make sure the motor automation settings are correct and that the safety and release systems are working properly.
- Only use original spare parts for any maintenance or repair work. The Firm disclaims all responsibility for the correct operation and safety of the automated system if parts from other manufacturers are used.
- Do not make any modifications to the automated system’s components unless explicitly authorized by the Firm.
- Instruct the system’s user on what residual risks may be encountered, on the control systems that have been applied and on how to open the system manually in an emergency. give the user guide to the end user.
- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accordance with the provisions of the laws in force. Keep nylon bags and polystyrene out of reach of children.
WIRING
WARNING! For connection to the mains power supply, use: a multicore cable with a cross-sectional area of at least 5x1.5mm
2 or 4x1.5mm
2 when dealing with threephase power supplies or 3x1.5mm
2 for single-phase supplies (by way of example, type H05 VV-F cable can be used with a cross-sectional area of 4x1.5mm
2 ). To connect auxiliary equipment, use wires with a cross-sectional area of at least 0.5 mm 2 .
- Only use pushbuttons with a capacity of 10A-250V or more.
- Wires must be secured with additional fastening near the terminals (for example, using cable clamps) in order to keep live parts well separated from safety extra low voltage parts.
- During installation, the power cable must be stripped to allow the earth wire to be connected to the relevant terminal, while leaving the live wires as short as possible. The earth wire must be the last to be pulled taut in the event the cable’s fastening device comes loose.
WARNING! safety extra low voltage wires must be kept physically separate from low voltage wires.
Only qualified personnel (professional installer) should be allowed to access live parts.
CHECKING THE AUTOMATED SYSTEM AND MAINTENANCE
Before the automated system is finally put into operation, and during maintenance work, perform the following checks meticulously:
- Make sure all components are fastened securely.
- Check starting and stopping operations in the case of manual control.
- Check the logic for normal or personalized operation.
- For sliding gates only: check that the rack and pinion mesh correctly with 2 mm of play along the full length of the rack; keep the track the gate slides on clean
- and free of debris at all times.
For sliding gates and doors only: make sure the gate’s running track is straight and horizontal and that the wheels are strong enough to take the weight of the
- gate.
For cantilever sliding gates only: make sure there is no dipping or swinging during operation.
- For swing gates only: make sure the leaves’ axis of rotation is perfectly vertical.
- Check that all safety devices (photocells, safety edges, etc.) are working properly and that the anti-crush safety device is set correctly, making sure that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
- Impact forces can be reduced by using deformable edges.
- Make sure that the emergency operation works, where this feature is provided.
- Check opening and closing operations with the control devices applied.
- Check that electrical connections and cabling are intact, making extra sure that insulating sheaths and cable glands are undamaged.
- While performing maintenance, clean the photocells’ optics.
- When the automated system is out of service for any length of time, activate the emergency release (see “EMERGENCY OPERATION” section) so that the operated part is made idle, thus allowing the gate to be opened and closed manually.
- If the power cord is damaged, it must be replaced by the manufacturer or their technical assistance department or other such qualified person to avoid any risk .
- If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months
WARNING!
Remember that the drive is designed to make the gate/door easier to use and will not solve problems as a result of defective or poorly performed installation or lack of maintenance
SCRAPPING
Materials must be disposed of in accordance with the regulations in force. There are no particular hazards or risks involved in scrapping the automated system. For the purpose of recycling, it is best to separate dismantled parts into like materials
(electrical parts - copper - aluminium - plastic - etc.).
DISMANTLING
If the automated system is being dismantled in order to be reassembled at another site, you are required to:
- Cut off the power and disconnect the whole electrical system.
- Remove the actuator from the base it is mounted on.
- Remove all the installation’s components.
- See to the replacement of any components that cannot be removed or happen to be damaged.
Anything that is not explicitly provided for in the installation manual is not allowed. The operator’s proper operation can only be guaranteed if the information given is complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein.
While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly.
30 THALIA P AVVERTENZE PER L’INSTALLATORE D811766_06
INSTALLATION MANUAL
2) GENERAL INFORMATION
The THALIA P control panel comes with standard factory settings. Any change must be made using the programmer with built-in display or universal handheld programmer. The Control unit completely supports the EELINK protocol.
Its main features are:
- Control of 1 or 2 24V BT motors
Note: 2 motors of the same type must be used.
- Electronic torque control with obstacle detection
- Limit switch control inputs based on motor selected
- Separate inputs for safety devices
- Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance or replacement easier. It comes with a series of prewired jumpers to make the installer’s job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77, 76-79, 81-82,
81-84. If the above-mentioned terminals are being used, remove the relevant jumpers.
Maximum motor power
Accessories power supply
AUX 1
AUX 2
AUX 3
LOCK
180W + 180W (24V )
NO 220230V~ powered contact (max.5A)
NO contact (220-230V~/max.5A)
NO contact (24V~/max.1A)
Flashing light 24V~ max. 25W
Dimensions see Fig. B
Fuses
N° of combinations see Fig. C
4 billion
Max.n° of transmitters that can be memorized 63
(*other voltages to order)
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
TESTING
The THALIA P panel controls (checks) the start relays and safety devices (photocells) before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working properly and check the wiring.
3) TECHNICAL SPECIFICATIONS
Power supply
Low voltage/mains insulation
Operating temperature range
Thermal overload protection
Dielectric rigidity
Motor output current
Motor relay switching current
220-230V 50/60Hz(*)
> 2MOhm 500V
-10 / +55°C
Software mains/LV 3750V~ for 1 minute max. 7.5A+7.5A
10A
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. C
WARNINGS - When performing wiring and installation, refer to the standards in force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other, or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
26
27
28
29
41
42
43
44
45
42
43
Terminal Definition
L
N
LINE
NEUTRAL
JP5
JP7
Single-phase power supply 220-230V 50/60Hz(*)
TRANSF PRIM Transformer primary winding connection, 220-230V.
JP21 TRANSF SEC
Board power supply:
24V~ Transformer secondary winding
24V= Buffer battery power supply
10
11
14
15
20
21
MOT1 +
MOT1 -
MOT2 +
MOT2 -
LIgHT 24v
Connection motor 1. Time lag during closing.
Check connections shown in Fig.E
Connection motor 2. Time lag during opening.
Check connections shown in Fig.E
Flashing light 24V output max. 25W.
22
23
AUX 1 -
220-230V~
POWERED
CONTACT
(Max. 5A)
Description
AUX 1 configurable output - Default setting ZONE LIgHT Output.
2ND RADIO CHANNEL/ SCA gATE OPEN LIgHT/ COURTESY LIgHT/ ZONE LIgHT/ STAIR LIgHT/ gATE OPEN ALARM/ FLASHINg LIgHT/
SOLENOID LATCH/ MAgNETIC LOCK.
Refer to “AUX output configuration” table.
24
25
AUX 2 - FREE
CONTACT
(N.O.)
(Max. 220-230V
5A)
AUX 3 - FREE
CONTACT
(N.O.)
(Max. 24V 1A)
LOCK 12V/24
+ REF SWE
SWC 1
SWO 1
SWC 2
SWO 2
SW 1
SW 2
AUX 2 configurable output - Default setting SCA gATE OPEN LIgHT Output.
2ND RADIO CHANNEL/ SCA gATE OPEN LIgHT/ COURTESY LIgHT command/ ZONE LIgHT command/ STAIR LIgHT/ gATE OPEN
ALARM/ FLASHINg LIgHT/ SOLENOID LATCH/ MAgNETIC LOCK.
Refer to “AUX output configuration” table.
AUX 3 configurable output - Default setting 2ND RADIO CHANNEL Output.
2ND RADIO CHANNEL/ SCA gATE OPEN LIgHT/ COURTESY LIgHT command/ ZONE LIgHT command/ STAIR LIgHT/ gATE OPEN
ALARM/ FLASHINg LIgHT/ SOLENOID LATCH/ MAgNETIC LOCK.
Refer to “AUX output configuration” table.
Type of lock logic= 0 - 12V solenoid latch output (max. 30W). Output activated with a pulse each time gate is opened.
Type of lock logic= 1 - 12V magnetic lock output (max. 15W). Output activated when gate is closed.
Type of lock logic= 2 - 24V solenoid latch output (max. 30W). Output activated with a pulse each time gate is opened.
Type of lock logic= 3 - 24V magnetic lock output (max. 15W). Output activated when gate is closed.
Limit switch common
Motor 1 closing limit switch SWC1 (N.C.).
Motor 1 opening limit switch SWO1 (N.C.).
Motor 2 closing limit switch SWC2 (N.C.).
Motor 2 opening limit switch SWO2 (N.C.).
Limit switch control motor 1.
For actuators with single-wire limit switch control.
Limit switch control motor 2.
For actuators with single-wire limit switch control.
THALIA P 31
Terminal Definition
41 + REF SWE
42
43
SW 1
SW 2
INSTALLATION MANUAL
Limit switch common
Limit switch control motor 1.
Limit switch control motor 2.
Description
50
51
24V-
24V+
Accessories power supply output.
52 24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
60
61
62
63
64
65
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
Common
IC 1
IC 2
Common
IC 3
IC 4
Common
STOP
SAFE 1
FAULT 1
SAFE 2
FAULT 2
Common
SAFE 3
FAULT 3
SAFE 4
FAULT 4
Common
SAFE 5
FAULT 5
SAFE 6
FAULT 6
IC 1 and IC 2 inputs common
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
Configurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
IC 3 and IC 4 inputs common
Configurable command input 3 (N.O.) - Default OPEN.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
Configurable command input 4 (N.O.) - Default CLOSE.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
STOP, SAFE 1 and SAFE 2 inputs common
The command stops movement. (N.C.)
If not used, leave jumper inserted.
Configurable safety input 1 (N.C.) - Default PHOT.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 1.
Configurable safety input 2 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 2.
SAFE 3 and SAFE 4 inputs common
Configurable safety input 3 (N.C.) - Default PHOT OP.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 3.
Configurable safety input 4 (N.C.) - Default PHOT CL.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 4.
SAFE 5 and SAFE 6 inputs common
Configurable safety input 5 (N.C.) - Default PHOT.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 5.
Configurable safety input 6 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
Test input for safety devices connected to SAFE 6.
Y
#
ANTENNA
SHIELD
Antenna input.
Use an antenna tuned to 433MHz. Use Rg58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna can interfere with radio reception. If the transmitter’s range is limited, move the antenna to a more suitable position.
AUX output configuration
Aux logic= 0 - 2ND RADIO CHANNEL output.
Contact stays closed for 1s when 2nd radio channel is activated.
Aux logic= 1 - SCA gATE OPEN LIgHToutput.
Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
Aux logic= 2 - COURTESY LIgHT command output.
Contact stays on for 90 seconds after the last operation.
Aux logic= 3 - ZONE LIgHT command output.
Contact stays closed for the full duration of operation.
Aux logic= 4 - STAIR LIgHT output.
Contact stays closed for 1 second at start of operation.
Aux logic= 5 - gATE OPEN ALARM output.
Contact stays closed if the leaf stays open for double the set TCA time.
Aux logic= 6 - FLASHINg LIgHT output.
Contact stays closed while leaves are operating.
Aux logic= 7 - SOLENOID LATCH output.
Contact stays closed for 2 seconds each time gate is opened.
Aux logic= 8 - MAgNETIC LOCK output.
Contact stays closed while gate is closed.
Command input configuration
IC logic= 0 - Input configured as Start E. Operation according to STEP-BY-STEP MOV . logic. External start for traffic light control.
32 THALIA P
INSTALLATION MANUAL
IC logic= 1 - Input configured as Start I. Operation according to STEP-BY-STEP MOV . logic. Internal start for traffic light control.
IC logic= 2 - Input configured as Open.
The command causes the leaves to open. If the input stays closed, the leaves stay open until the contact is opened. When the contact is open, the automated device closes following the TCA time, where activated.
IC logic= 3 - Input configured as Closed.
The command causes the leaves to close.
IC logic= 4 - Input configured as Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to STEP-BY-STEP . logic
IC logic= 5 - Input configured as Timer.
Operation same as open except closing is guaranteed even after a mains power outage.
IC logic= 6 - Input configured as Timer Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. If the input stays closed, the leaf stays open until the contact is opened. If the input stays closed and a Start E,
Start I or Open command is activated, a complete opening-closing cycle is performed before returning to the pedestrian opening position. Closing is guaranteed even after a mains power outage.
Safety input configuration
SAFE logic= 0 - Input configured as Phot (photocell) non tested (*). (fig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared. If not used, leave jumper inserted.
SAFE logic= 1 - Input configured as Phot test (tested photocell). (fig.F, ref.2).
Switches photocell testing on at start of operation. When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared.
SAFE logic= 2 - Input configured as Phot op (photocell active during opening only) non tested (*). (fig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during closing. During opening, stops motion for as long as the photocell beam stays broken. If not used, leave jumper inserted.
SAFE logic= 3 - Input configured as Phot op test (tested photocell active during opening only (fig.F, ref.2).
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during closing. During opening, stops motion for as long as the photocell beam stays broken.
SAFE logic= 4 - Input configured as Phot cl (photocell active during closing only) non tested (*). (fig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately. If not used, leave jumper inserted.
SAFE logic= 5 - Input configured as Phot cl test (tested photocell active during closing only (fig.F, ref.2).
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately.
SAFE logic= 6 - Input configured as Bar (safety edge) non tested (*). (fig.F, ref.3).
Enables connection of devices not equipped with supplementary test contacts. The command reverses movement for 2 sec.. If not used, leave jumper inserted.
SAFE logic= 7 - Input configured as Bar (tested safety edge (fig.F, ref.4).
Switches safety edge testing on at start of operation. The command reverses movement for 2 sec.
SAFE logic= 8 - Input configured as Bar 8k2 (fig.F, ref.5). Input for resistive edge 8K2.
The command reverses movement for 2 sec.
(*) If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
6) MOTOR WIRING Fig. E
7) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
7.1) TESTED DEVICES Fig. F
7.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS FIG. D
8) CALLING UP MENUS: FIG. 1
8.1) PARAMETERS MENU (
8.2) LOGIC MENU ( LOGIC
PARA ) (PARAMETERS TABLE “A”)
) (LOGIC TABLE “B”)
8.3) RADIO MENU ( radio ) (RADIO TABLE “C”)
- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER’S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced features:
• Cloning of master transmitter (rolling code or fixed code).
• Cloning to replace transmitters already entered in receiver.
• Transmitter database management.
• Receiver community management.
2. Check the impact forces: if they fall within the limits (**) skip to point 10 of the procedure, otherwise table.
4. Check the impact forces again: if they fall within the limits (**) skip to point 10 of the procedure, otherwise
5. Apply a shock absorber profile
6. Check the impact forces again: if they fall within the limits (**) skip to point 10 of the procedure, otherwise
7. Apply pressure-sensitive or electro-sensitive protective devices (such as a safety edge)
(**)
8. Check the impact forces again: if they fall within the limits (**) skip to point 10 of the procedure, otherwise
9. Allow the drive to move only in “Deadman” mode
10. Make sure all devices designed to detect obstacles within the system’s operating range are working properly
(*) Before running the autoset function, make sure you have performed all the assembly and make-safe operations correctly, as set out in the installation warnings in the drive’s manual.
8.8) LIMIT SWITCH ADJUSTMENT MENU ( L.SW ADJ )
Used to adjust limit switches for motors featuring encoders.
The menu is enabled with the following motors: LUX BT, LUX g BT. In all other cases, the “ NOT AVAILABLE ” message is displayed.
NOTE: these operations must be performed in deadman mode at reduced speed messages relating to motor 1 will be displayed (“ OPm1
1 Mot. act
” and “ CLm1 ”).
” is set, only
8.4) DEFAULT MENU ( default )
Restores the controller’s DEFAULT factory settings. Following this reset, you will need to run the AUTOSET function again.
8.5) LANGUAGE MENU ( language )
Used to set the programmer’s language on the display.
8.6) AUTOSET MENU ( AUTOset )
• Launch an autoset operation by going to the relevant menu.
• As soon as you press the OK button, the “.... .... ....” message is displayed and the control unit commands the device to perform a full cycle (opening followed by closing), during which the minimum torque value required to move the leaf is set automatically.
The number of cycles required for the autoset function can range from 1 to 3.
to use the START and STOP commands or the display.
Once this operation is complete, the control unit will have automatically set the optimum torque values. Check them and, where necessary, edit them as described in the programming section.
WARNING!! Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
Impact forces can be reduced by using deformable edges.
8.9) STATISTICS MENU
Used to view the version of the board, the total number of operations (in hundreds), the number of transmitters memorized and the last 30 errors (the first 2 digits indicate the position, the last 2 give the error code). Error 01 is the most recent.
8.10) PASSWORD MENU
Used to set a password for the board’s wireless programming.
9) CLOSING LIMIT SWITCH PRESSURE Fig. G Ref. A-B
OPENING DIRECTION Fig. G Ref. C-D
10) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER VERSION> V1.40 (Fig. H) Refer to specific manual.
WARNING! Incorrect settings can result in damage to property and injury to people and animals.
WARNING: Check that the force of impact measured at the points by standard EN 12453.
Impact forces can be reduced by using deformable edges.
Warning!! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor the automated system’s movements and keep people and property out of range of the automated system.
8.7)INSTALLATION TEST PROCEDURE
1. Run the AUTOSET cycle (*)
11) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
THALIA P 33
INSTALLATION MANUAL
TABLE “A” - PARAMETERS MENU - ( PARA )
Parameter min. max. Default Personal
OPEN DELAY
TI E
0 10 3
CLS DELAY
TI E
0 25 3
TCA 0 120 10
TRF.LGHT.CLR.T
OP.DIST.SLOUD
CL.DIST.SLOUD
DIST.DECEL
OP.FORCE
CLS.FORCE
OP SPEED
CL SPEED
SLOW SPEED
1
0
0
0
1
1
15
15
15
180
50
50
50
99
99
99
99
99
40
10
10
15
50
50
99
99
25
Definition
Motor 2 opening delay time [s]
Motor 1 closing delay time [s]
Automatic closing time
[s]
Time-to-clear traffic light zone [s]
Description
Motor 2 opening delay time with respect to motor 1.
Motor 1 closing delay time with respect to motor 2.
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
Slow-down distance during opening [%]
Slow-down distance during closing [%]
Deceleration distance
[%]
Leaf force during opening [%]
Leaf force during closing [%]
Opening speed [%}
Closing speed [%]
Slow-down speed [%]
Slow-down distance for motor(s) during opening, given as a percentage of total travel. WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage of total travel. WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
Deceleration distance (switch from running speed to slow-down speed) for motor(s) both during opening and during closing, given as a percentage of total travel. WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
Force exerted by leaf/leaves during opening. This is the percentage of force delivered, beyond the force stored during the autoset cycle (and subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements are met with the set value (*). Install anticrush safety devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of force delivered, beyond the force stored during the autoset cycle (and subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements are met with the set value (*). Install anticrush safety devices where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during opening. WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required. WARNING: when the display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing. WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required. WARNING: when the display reads "SET", obstacle detection is not active.
Opening and closing speed of motor(s) during slow-down stage, given as a percentage of maximum running speed. WARNING: Once the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: When the display reads “”SET””, obstacle detection is not active.
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
34 THALIA P
INSTALLATION MANUAL
TABLE “B” - LOGIC MENU - ( logic
)
Logic
MOTOR TYPE
TCA
FAST CLS.
STEP-BY-STEP
MOVEMNT
PRE-ALARM
HOLD-TO-RUN
IBL OPEN
|IBL TCA
IBL CLOSE
RAM BLOW C.OP
RAM BLOW C.CL
BLOC PERSIST
Definition
Motor type
(Set the type of motor connected to the board).
Automatic Closing
Time
Fast closing
Step-by-step movement
Pre-alarm
Deadman
Block pulses during opening
Block pulses during
TCA
Block pulses during closing
Hammer during opening
Hammer during closing
Stop maintenance
Default
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
1
0
1
0
Cross out setting used
0
1
Motors not active
ELI 250 BT
6
0
1
0
4
5
2
3
PHOBOS BT
IgEA BT
LUX BT
LUX g BT
SUB BT
Logic not enabled
Switches automatic closing on
Logic not enabled
1
0
1
2
Optional extras
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I,
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse during closing reverses movement.
Inputs configured as Start E, Start I,
Ped operate with 2-step logic. Movement reverses with each pulse.
step-by-step mov.
2 STEP
CLOSED
DURINg
CLOSINg
OPEN
OPENS
DURINg
OPENINg
CLOSES
AFTER STOP OPENS
3 STEP
OPENS
CLOSES
4 STEP
OPENS
STOP + TCA STOP + TCA
OPENS
STOPS
CLOSES
OPENS
0
1
0
1
2
1
0
1
0
1
The flashing light comes on at the same time as the motor(s) start.
The flashing light comes on approx. 3 seconds before the motor(s) start.
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
Logic not enabled
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Logic not enabled
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Logic not enabled
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on in the direction of the stop for approx. 3 seconds. This operation is performed every hour.
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil due to a drop in temperature during extended pauses, such as during the night, or due to internal leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
THALIA P 35
Logic
PRESS SWC
ICE
1 MOT.ON
OPEN IN OTHER
DIRECT.
SAFE 1
SAFE 2
SAFE 3
SAFE 4
SAFE 5
SAFE 6
Definition
Closing limit switch pressure
Ice feature
1 motor active
Open in other direction
Configuration of safety input SAFE 1.
72
Configuration of safety input SAFE 2.
74
Configuration of safety input SAFE 3.
77
Configuration of safety input SAFE 4.
79
Configuration of safety input SAFE 4.
79
Configuration of safety input SAFE 6.
84
Default
0
0
0
0
0
6
2
4
0
6
1
2
3
4
5
6
7
5
6
7
8
0
0
1
2
3
4
0
1
0
1
INSTALLATION MANUAL
Cross out setting used
0
1
0
1
Optional extras
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing limit switch must be adjusted accurately (Fig.g Ref.B).
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop sensor interpreting this as an obstacle.
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as the mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the closing limit switches to trip slightly earlier (Fig.g Ref.A).
The Amperostop safety trip threshold stays at the same set value.
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
This feature is useful when dealing with installations running at low temperatures.
WARNINg: once this feature has been activated, you will need to perform an autoset opening and closing cycle.
Both motors active (2 leaves).
Only motor 1 active (1 leaf).
Standard operating mode (See Fig.g Ref. C).
Opens in other direction to standard operating mode (See Fig. g Ref.D)
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Bar 8k2.
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
0 Input configured as Start E.
IC 1
Configuration of command input IC 1.
61
0
1 Input configured as Start I.
IC 2
IC 3
Configuration of command input IC 2.
62
Configuration of command input IC 3.
64
4
2
4
5
2
3
Input configured as Open.
Input configured as Close.
Input configured as Ped.
Input configured as Timer.
IC 4
Configuration of command input IC 4.
65
3 6 Input configured as Timer Pedestrian.
36 THALIA P
INSTALLATION MANUAL
Logic
AUX 1
AUX 2
AUX 3
LOCK
FIXED CODE
RADIO PROG
SERIAL MODE
ADDRESS
EXPI1
Definition
Configuration of
AUX 1 output.
22-23
Configuration of
AUX 2 output.
24-25
Configuration of
AUX 3 output.
26-37
Type of lock.
28-29
Fixed code
Transmitter programming
Serial mode
(Identifies how board is configured in a BFT network connection).
Address
Configuration of
EXPI1 input on input-output expansion board.
1-2
Default
3
1
0
0
0
1
0
Cross out setting used
4
5
6
2
3
0
1
7
8
0
1
2
3
0
1
0
1
0
Optional extras
Output configured as 2nd Radio Channel.
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light
Output configured as Alarm
Output configured as Flashing light
Output configured as Latch
Output configured as Magnetic lock
Output configured as 12V solenoid latch.
Output configured as 12V magnetic lock.
Output configured as 24V solenoid latch.
Output configured as 24V magnetic lock.
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.
Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memorized in standard mode via the radio menu.
2- Press within 10s the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10s: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
0
1
[ ___ ]
0
1
2
5
6
3
4
7
8
9
10
11
12
13
14
Identifies board address from 0 to 127 in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as Phot test safety (tested photocell).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test input, EXPFAULT1.
Input configured as Phot op test safety (tested photocell active during opening only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test input, EXPFAULT1.
Input configured as Phot cl test safety (tested photocell active during closing only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test input, EXPFAULT1.
Input configured as Bar safety (tested safety edge).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test input, EXPFAULT1.
THALIA P 37
Logic
EXPI2
EXPO1
EXPO2
TRAFFIC LIGHT
PREFLASHING
Definition
Configuration of
EXPI2 input on input-output expansion board.
1-3
Configuration of
EXPO2 output on input-output expansion board
4-5
Configuration of
EXPO2 output on input-output expansion board
6-7
Traffic light preflashing
TRAFFIC LIGHT
RED LAMP
ALWAYS ON
Steadily lit red light
Default
0
9
9
0
0
Cross out setting used
7
8
9
0
1
0
3
4
1
2
5
6
0
9
10
0
1
2
3
6
7
4
5
8
Optional extras
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Output configured as 2 nd Radio Channel.
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light.
Output configured as Alarm.
Output configured as Flashing light.
Output configured as Latch.
Output configured as Magnetic lock.
Output configured as Traffic Light control with TLB board.
Pre-flashing switched off.
Red lights flash, for 3 seconds, at start of operation.
Red lights off when gate closed.
1 Red lights on when gate closed.
TABLE “C” – RADIO MENU ( RADIO )
Logic
Add start add 2ch erase 64
Description
Add Start Key associates the desired key with the Start command
Add 2ch Key associates the desired key with the 2nd radio channel command. Associates the desired key with the 2nd radio channel command. If no output is configured as 2nd Radio Channel Output, the 2nd radio channel controls the pedestrian opening.
Erase List
WARNING! Erases all memorized transmitters from the receiver’s memory.
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
TORAUTOMATIC
Put Lopaica
10020
23
ZAGREB www.torautomatic.hr
[email protected]
38 THALIA P
Download
Advertisement
Key features
Tube arrangement predispositions
Safety device connections
Limit switch/encoder input configurations
Simplified menu programming
Motor type selection
Automatic closing time adjustments
Safety input management
Frequently asked questions
Connect one pair of non-tested photocells according to the wiring diagram provided in the manual, ensuring proper connection to the safety input terminals.
Access the simplified menu on the control panel and follow the instructions for transmitter programming to add or erase remote controls.
Refer to the motor specifications section, which provides details on wiring and configuration for ELI 250 BT, PHOBOS BT, IGEA BT, LUX BT, LUX G BT and SUB BT motors.
Use the simplified menu to access the parameters and logic settings, where you can adjust the automatic closing time according to your needs.
The control panel supports various safety devices, including photocells, safety edges, and other safety inputs, which can be connected to the appropriate terminals as per the wiring diagrams.