Advertisement
Advertisement
Installation & Operating Manual Installation and Appliance Setup - Care and Operation INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. Call your dealer for questions on Installation, Operation, or Service. NOTICE: SAVE THESE INSTRUCTIONS SDDVT Series Stardance® Direct Vent Gas Heater Models: SDDVTCBSB, SDDVTBSSB, SDDVTBDSB, SDDVTBMSB, SDVTSCCB, SDVTSCBS, SDVTSCBD, SDVTSCBM ! WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. 'RQRWVWRUHRUXVHJDVROLQHRURWKHUÀDPPDEOH vapors and liquids in the vicinity of this or any other appliance. • WHAT TO DO IF YOU SMELL GAS – Do not try to light any appliance. – Do not touch any electrical switch; do not use any phone in your building. – Leave the building immediately. – Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. – If you cannot reach your gas supplier, call the ¿UHGHSDUWPHQW • Installation and service must be performed E\ D TXDOL¿HG LQVWDOOHU VHUYLFH DJHQF\ RU WKH gas supplier. DANGER HOT GLASS WILL CAUSE BURNS. CERTIFIED SAFETY BARRIER DO NOT TOUCH GLASS UNTIL COOLED. Installation and service of this appliance should be performed by TXDOL¿HGSHUVRQQHO+HDUWK +RPH7HFKQRORJLHVUHFRPPHQGV ++7)DFWRU\7UDLQHGRU1),FHUWL¿HGSURIHVVLRQDOV NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed. 1 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. 7KDQN\RXDQGFRQJUDWXODWLRQVRQ\RXUSXUFKDVHRID9HUPRQW&DVWLQJVVWRYH IMPORTANT:5HDGDOOLQVWUXFWLRQVDQGZDUQLQJVFDUHIXOO\EHIRUHVWDUWLQJLQVWDOODWLRQ)DLOXUHWRIROORZWKHVHLQVWUXFWLRQVPD\UHVXOWLQD SRVVLEOH¿UHKD]DUGDQGZLOOYRLGWKHZDUUDQW\ Table of Contents Important Safety Information 3 Operating Instructions 31 Massachusetts Safety Information4 California Safety Information4 <RXU)LUVW)LUH31 Pilot and Burner Inspection31 )ODPH 7HPSHUDWXUH$GMXVWPHQW31 )ODPH&KDUDFWHULVWLFV31 /LJKWLQJDQG2SHUDWLQJ,QVWUXFWLRQV32 7URXEOHVKRRWLQJ33 5HDG%HIRUH/LJKWLQJ34 Pre-Installation 5 Stove Dimensions5 Installation Requirements6 Clearance Requirements6 Parallel Installation7 Corner Installation7 :DOODQG&HLOLQJ&OHDUDQFHV7 +HDUWK5HTXLUHPHQWV7 *DV6SHFL¿FDWLRQV8 *DV,QOHWDQG0DQLIROG3UHVVXUHV8 +LJK(OHYDWLRQV8 +RUL]RQWDO7HUPLQDWLRQ8 Vertical Termination9 5HVWULFWRU3ODWH$GMXVWPHQWIRU([WHQGHG3LSH5XQV 9 Vent Termination Clearances10 *HQHUDO9HQWLQJ,QIRUPDWLRQ±7HUPLQDWLRQ/RFDWLRQ 11 7HUPLQDWLRQ&OHDUDQFHV12 Assembly & Installation 13 9HQWLQJ5HTXLUHPHQWVDQG2SWLRQV13 $VVHPEOLQJWKH6WRYH14 ,QVWDOOWKH2SWLRQDO)DQ±6''970RGHOV(Millivolt Only) ............ 14 9HQWLQJ6\VWHP$VVHPEO\16 Important Safety Information16 Before You Start16 ,QVWDOOWKH9HQW$GDSWHU3LSH17 $VVHPEOH6OLS6HFWLRQV18 Secure the Vent Sections18 Disassemble Vent Sections19 +RUL]RQWDO7HUPLQDWLRQ&DS19 Divert Roof Run-off20 Vertical Side Wall Installation20 9HQW7HUPLQDWLRQ%HORZ*UDGH21 9HUWLFDO7KURXJK7KH5RRI$SSOLFDWLRQLQVWDOODWLRQ 22 9HQWLQJ6\VWHP$VVHPEO\1DWXUDO9HQW23 ,QVWDOO/RJ6HW24 ,QVWDOO212))6ZLWFK±6''970RGHOV(Millivolt Only) 26 Thermostat Connection (optional)26 6LJQDWXUH&RPPDQG6\VWHP 6& 26 -XQFWLRQ%R[:LULQJ27 Command Center Wall Installation27 Wall Switch Installation 27 &RQQHFWWKH*DV6XSSO\/LQH28 Burner Information28 6LJQDWXUH&RPPDQG:LULQJ'LDJUDP29 Install the Safety Barrier30 ,QVWDOOWKH0HVKDQG*ULOO30 2 Signature Command Operating Instructions 36 )HDWXUHV36 Battery Installation36 6\VWHP&RQ¿JXUDWLRQ6HWXS36 Operating instructions 38 7XUQLQJRQWKHVWRYH38 &RPPDQG&HQWHU2SHUDWLRQV38 ,QLWLDOL]DWLRQDQG6HWWLQJXS39 )XQFWLRQVDQG2SHUDWLRQV40 6DIHW\)HDWXUHV43 Troubleshooting 44 7URXEOHVKRRWLQJ±6,*1$785(&200$1'6<67(0 44 Fuel Conversion 46 Cleaning & Maintenance 51 $QQXDO6\VWHP,QVSHFWLRQ51 /RJVHWDQG%XUQHU&OHDQLQJDQG,QVSHFWLRQ51 Care of Cast Iron51 &OHDQLQJWKH*ODVV51 *DVNHW5HSODFHPHQW52 ,QVSHFWWKH9HQW6\VWHP$QQXDOO\52 &KHFNWKH*DV)ODPH5HJXODUO\52 *ODVV5HSODFHPHQW52 Wiring Diagrams 53 Service Parts List 55 Optional Accessories 59 Limited Lifetime Warranty 60 Î = Contains updated information Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Massachusetts safety information 7KH6WDUGDQFH'LUHFW9HQW5RRPKHDWHU0RGHO1RV6''97&%6% SDDV TBSSB, SDDV TBDSB, SDDV TBMSB, SDV TSCCB, 6'976&%66'976&%'6'976&%0LVDYHQWHGJDVDSSOLDQFH OLVWHGWRWKH$16,6WDQGDUG=DQG&6$IRU 9HQWHG5RRPKHDWHUVDQG&6$0*DV)LUHG$SSOLDQFHV )RU8VHDW+LJK$OWLWXGHV The installation of the Stardance Direct Vent Room heater must conform with local codes, or in the absence of local codes, with 1DWLRQDO)XHO*DV&RGH$16,=1)3$²ODWHVWHGLWLRQDQG &6$%,QVWDOODWLRQ&RGH (;&(37,21'RQRWGHUDWHWKLV DSSOLDQFHIRUDOWLWXGH0DLQWDLQWKHPDQLIROGSUHVVXUHDWLQFKHV ZFIRU1DWXUDO*DVDQGLQFKHVZFIRU/3JDVDWPD[LPXP LQSXW 7KLVDSSOLDQFHLVRQO\IRUXVHZLWKWKHW\SHRIJDVLQGLFDWHGRQWKH UDWLQJ SODWH 7KLV DSSOLDQFH LV QRW FRQYHUWLEOH IRU XVH ZLWK RWKHU JDVHVXQOHVVDFHUWL¿HGNLWLVXVHG Installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equipment VKDOOEHSHUIRUPHGRQO\E\DTXDOL¿HGDJHQF\SUHIHUDEO\1),RU :(77 &DQDGD FHUWL¿HG7KHWHUP³TXDOL¿HGDJHQF\PHDQVDQ\ LQGLYLGXDO¿UPFRUSRUDWLRQRUFRPSDQ\WKDWHLWKHULQSHUVRQ or through a representative is engaged in and is responsible for (a) installation or replacement of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction. The Stardance Direct Vent Room heater should be inspected EHIRUHXVHDQGDWOHDVWDQQXDOO\E\DTXDOL¿HGVHUYLFHDJHQF\,WLV imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. The Stardance Direct Vent Room heater and its individual shut-off YDOYHPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\SLSLQJGXULQJDQ\ SUHVVXUHWHVWLQJRIWKDWV\VWHPDWWHVWSUHVVXUHVLQH[FHVVRI SVLJ N3D The Stardance Direct Vent Room heater must be isolated from the JDVVXSSO\SLSLQJV\VWHPE\FORVLQJLWVLQGLYLGXDOPDQXDOVKXWRII YDOYHGXULQJDQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\SLSLQJV\VWHP DWWHVWSUHVVXUHVHTXDOWRRUOHVVWKDQSVLJ $QDFFHVVLEOHWDSLVORFDWHGDERYHWKHSLORW2Q2IINQREIRUFKHFNLQJ WKHLQOHWSUHVVXUH ‘Direct Vent’ describes a sealed combustion system in which LQFRPLQJ RXWVLGH DLU IRU FRPEXVWLRQ DQG RXWJRLQJ H[KDXVW HQWHU DQGH[LWWKURXJKWZRVHSDUDWHFRQFHQWULFSDVVDJHVZLWKLQWKHVDPH VHDOHGYHQWV\VWHP7KHV\VWHPGRHVQRWXVHURRPDLUWRVXSSRUW FRPEXVWLRQ7KH'LUHFW9HQWV\VWHPSHUPLWVWKHJDVDSSOLDQFHWR EHYHQWHGGLUHFWO\WRWKHRXWVLGHDWPRVSKHUHWKURXJKWKHVLGHRIWKH KRXVHRUYHUWLFDOO\WKURXJKWKHURRI&RQYHQWLRQDOYHQWLQJV\VWHPV 1DWXUDO9HQW WDNHDLUIURPWKHURRPIRUFRPEXVWLRQDQGYHQWWKH H[KDXVWYHUWLFDOO\WKURXJKWKHURRIWRWKHDWPRVSKHUH The Stardance Direct Vent Room heater, when installed, must EHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFHZLWKORFDOFRGHVRULQWKH DEVHQFHRIORFDOFRGHVZLWKWKH1DWLRQDO(OHFWULFDO&RGH$16,1)3$ ODWHVWHGLWLRQ RURIWKHFXUUHQW&DQDGLDQ(OHFWULFDO&RGH& Due to high temperatures this appliance should be located out RIWUDI¿FDQGDZD\IURPIXUQLWXUHDQGGUDSHULHV WARNING: This appliance is hot while in operation. Keep children, clothing, and furniture away. Contact may cause burns or ignition of combustible materials. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a stove or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces. &ORWKLQJRURWKHUÀDPPDEOHPDWHULDOVVKRXOGQRWEHSODFHG on or near the appliance. Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appliance. The appliance area must be kept clear and free from combustible PDWHULDOVJDVROLQHDQGRWKHUÀDPPDEOHYDSRUVDQGOLTXLGV 7KH ÀRZ RI FRPEXVWLRQ DQG YHQWLODWLRQ DLU PXVW QRW EH obstructed. The installation must include adequate accessibility and clearance for servicing and proper operation. WARNING: Do not operate the Room heater with the glass panel removed, cracked or broken. Replacement of the panel should EHGRQHE\DOLFHQVHGRUTXDOL¿HGVHUYLFHSHUVRQ Do not use this appliance if any part has been under water. ,PPHGLDWHO\FDOODTXDOL¿HGVHUYLFHWHFKQLFLDQWRLQVSHFWWKH appliance and to replace any part of the control system and any gas control which has been under water. Do not burn wood, trash or any other material for which this appliance was not designed. This appliance is designed to burn either natural gas or propane only. 7KLVJDVDSSOLDQFHPXVWQRWEHFRQQHFWHGWRDFKLPQH\ÀXH serving a separate solid-fuel burning appliance. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. * Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer. 7KLV DSSOLDQFH LV DSSURYHG IRU EHGURRP LQVWDOODWLRQV LQ WKH 86 DQG&DQDGD This appliance may be installed in an aftermarket* manufactured PRELOH KRPHZKHUHQRWSURKLELWHGE\VWDWHRUORFDOFRGHV WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. 3 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Requirements for the Commonwealth of Massachusetts $OOJDV¿WWLQJDQGLQVWDOODWLRQRIWKLVKHDWHUVKDOORQO\EHGRQH E\DOLFHQVHGJDV¿WWHURUOLFHQVHGSOXPEHU )RUDOOVLGHZDOOKRUL]RQWDOO\YHQWHGJDVIXHOHGHTXLSPHQW LQVWDOOHGLQHYHU\GZHOOLQJEXLOGLQJRUVWUXFWXUHXVHGLQZKROH RULQSDUWIRUUHVLGHQWLDOSXUSRVHVLQFOXGLQJWKRVHRZQHGRU operated by the Commonwealth and where the side wall H[KDXVWYHQWWHUPLQDWLRQLVOHVVWKDQVHYHQ IHHWDERYH ¿QLVKHGJUDGHLQWKHDUHDRIWKHYHQWLQJLQFOXGLQJEXWQRW OLPLWHG WR GHFNV DQG SRUFKHV WKH IROORZLQJ UHTXLUHPHQWV VKDOOEHVDWLV¿HG Installation of Carbon Monoxide Detectors $WWKHWLPHRILQVWDOODWLRQRIWKHVLGHZDOOKRUL]RQWDOYHQWHG JDVIXHOHGHTXLSPHQWWKHLQVWDOOLQJSOXPEHURUJDV¿WWHUVKDOO REVHUYHWKDWDKDUGZLUHGFDUERQPRQR[LGHGHWHFWRUZLWKDQ DODUPLVLQVWDOOHGRQHDFKDGGLWLRQDOOHYHORIWKHGZHOOLQJ EXLOGLQJ RU VWUXFWXUH VHUYHG E\ WKH VLGH ZDOO KRUL]RQWDO YHQWHGJDVIXHOHGHTXLSPHQW,WVKDOOEHWKHUHVSRQVLELOLW\ RI WKH SURSHUW\ RZQHU WR VHFXUH WKH VHUYLFHV RI TXDOL¿HG licensed professionals for the installation of hard wired carbon PRQR[LGHGHWHFWRUV ,QWKHHYHQWWKDWWKHVLGHZDOOKRUL]RQWDOO\YHQWHGJDVIXHOHG equipment is installed in a crawl space or an attic, the hard ZLUHG FDUERQ PRQR[LGH GHWHFWRU ZLWK DODUP DQG EDWWHU\ EDFNXSPD\EHLQVWDOOHGRQWKHQH[WDGMDFHQWÀRRUOHYHO In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above UHTXLUHPHQWVSURYLGHGKRZHYHUWKDWGXULQJVDLGWKLUW\ GD\SHULRGDEDWWHU\RSHUDWHGFDUERQPRQR[LGHGHWHFWRUZLWK DQDODUPVKDOOEHLQVWDOOHG Approved Carbon Monoxide Detectors (DFKFDUERQPRQR[LGHGHWHFWRUDVUHTXLUHGLQDFFRUGDQFH ZLWKWKHDERYHSURYLVLRQVVKDOOFRPSO\ZLWK1)3$DQG $16,8/OLVWHGDQG,$6FHUWL¿HG Signage $PHWDORUSODVWLFLGHQWL¿FDWLRQSODWHVKDOOEHSHUPDQHQWO\ mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, ³*$69(17',5(&7/<%(/2:.((3&/($52)$// 2%6758&7,216 Stardance Direct Vent &HUWL¿HGWR$16,=&6$9HQWHG Gas Heaters Exemptions 7KHIROORZLQJHTXLSPHQWLVH[HPSWIURP&05 D WKURXJK • 7KH HTXLSPHQW OLVWHG LQ &KDSWHU HQWLWOHG ³(TXLSPHQW 1RW5HTXLUHG7R%H9HQWHGLQWKHPRVWFXUUHQWHGLWLRQRI 1)3$DVDGRSWHGE\WKH%RDUGDQG • 3URGXFW$SSURYHGVLGHZDOOKRUL]RQWDOO\YHQWHGJDVIXHOHG equipment installed in a room or structure separate from WKHGZHOOLQJEXLOGLQJRUVWUXFWXUHXVHGLQZKROHRULQSDUW IRUUHVLGHQWLDOSXUSRVHV Manufacturer Requirements Gas Equipment Venting System Provided :KHQ WKH PDQXIDFWXUHU RI 3URGXFW $SSURYHG VLGH ZDOO KRUL]RQWDOO\YHQWHGJDVHTXLSPHQWSURYLGHVDYHQWLQJV\VWHP GHVLJQRUYHQWLQJV\VWHPFRPSRQHQWVZLWKWKHHTXLSPHQW the instructions provided by the manufacturer for installation RIWKHHTXLSPHQWDQGWKHYHQWLQJV\VWHPVKDOOLQFOXGH • 'HWDLOHG LQVWUXFWLRQV IRU WKH LQVWDOODWLRQ RI WKH YHQWLQJ V\VWHPGHVLJQRUWKHYHQWLQJV\VWHPFRPSRQHQWVDQG • $ FRPSOHWH SDUWV OLVW IRU WKH YHQWLQJ V\VWHP GHVLJQ RU YHQWLQJV\VWHP Gas Equipment Venting System NOT Provided :KHQ WKH PDQXIDFWXUHU RI D 3URGXFW$SSURYHG VLGH ZDOO KRUL]RQWDOO\YHQWHGJDVIXHOHGHTXLSPHQWGRHVQRWSURYLGH WKHSDUWVIRUYHQWLQJWKHÀXHJDVHVEXWLGHQWL¿HV³VSHFLDO YHQWLQJ V\VWHPV WKH IROORZLQJ UHTXLUHPHQWV VKDOO EH VDWLV¿HGE\WKHPDQXIDFWXUHU • 7KHUHIHUHQFHG³VSHFLDOYHQWLQJV\VWHPLQVWUXFWLRQVVKDOO be included with the appliance or equipment installation instructions; and • 7KH³VSHFLDOYHQWLQJV\VWHPVVKDOOEH3URGXFW$SSURYHG by the Board, and the instructions for that system shall LQFOXGHDSDUWVOLVWDQGGHWDLOHGLQVWDOODWLRQLQVWUXFWLRQV $FRS\RIDOOLQVWDOODWLRQLQVWUXFWLRQVIRUDOO3URGXFW$SSURYHG VLGHZDOOKRUL]RQWDOO\YHQWHGJDVIXHOHGHTXLSPHQWDOOYHQWLQJ LQVWUXFWLRQVDOOSDUWVOLVWVIRUYHQWLQJLQVWUXFWLRQVDQGRUDOO YHQWLQJGHVLJQLQVWUXFWLRQVVKDOOUHPDLQZLWKWKHDSSOLDQFH RUHTXLSPHQWDWWKHFRPSOHWLRQRIWKHLQVWDOODWLRQ California safety information ! WARNING This product and the fuels used to operate this product OLTXLG SURSDQH RU QDWXUDO JDV DQG WKH SURGXFWV RI FRPEXVWLRQ RI VXFK IXHOV FDQ H[SRVH \RX WR FKHPLFDOV LQFOXGLQJ EHQ]HQH ZKLFK LV NQRZQ WR WKH 6WDWH RI &DOLIRUQLD WR FDXVH FDQFHU DQG UHSURGXFWLYH KDUP )RU PRUHLQIRUPDWLRQJRWRZZZ3:DUQLQJVFDJRY Inspection 7KHVWDWHRUORFDOJDVLQVSHFWRURIWKHVLGHZDOOKRUL]RQWDOO\ YHQWHGJDVIXHOHGHTXLSPHQWVKDOOQRWDSSURYHWKHLQVWDOODWLRQ unless, upon inspection, the inspector observes carbon PRQR[LGHGHWHFWRUVDQGVLJQDJHLQVWDOOHGLQDFFRUGDQFHZLWK WKHSURYLVLRQVRI&05 D WKURXJK 4 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Stardance Direct Vent Stove Dimensions :HLJKW)XOO\DVVHPEOHGOEV 6HH)LJXUH IRU)OXH&ROODU&HQWHUOLQH'LPHQVLRQV 7" Outer Dia. (178 mm) 12-5/8” (321 mm) Flue Collar C L 2-7/8” (73 mm) 26-3/4" (680 mm) Supply Inlet CL 25-1/2" (648 mm) 3" (76 mm) 14-1/2" (355 mm) Figure 1 - Stardance dimensions. 5 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Installation Requirements Direct Vent System Only The installation must conform with local codes or, in the DEVHQFHRIORFDOFRGHVZLWKWKH1DWLRQDO)XHO*DV&RGH $16,=1)3$±ODWHVWHGLWLRQ (;&(37,21'R QRWGHUDWHWKLVDSSOLDQFHIRUDOWLWXGH0DLQWDLQWKHPDQLIROG SUHVVXUH DW ZF IRU 1DWXUDO *DV DQG ZF IRU 3URSDQH A D B C In Canada, installation must be in accordance with the current &6$%,QVWDOODWLRQ&RGHVDQGRUORFDOFRGHV 7KHLQVWDOODWLRQVKRXOGEHGRQHE\DTXDOL¿HGVHUYLFHSHUVRQ ZKR LV IDPLOLDU ZLWK WKH EXLOGLQJ FRGHV DQG LQVWDOODWLRQ techniques appropriate for your area to accomplish a safe DQGHIIHFWLYHLQVWDOODWLRQ <RXUGHDOHURU\RXUORFDOJDVVXSSOLHUZLOOEHDEOHWRUHIHUD TXDOL¿HGVHUYLFHSHUVRQ ! WARNING 'XHWRKLJKWHPSHUDWXUHVWKHKHDWHUVKRXOGEHORFDWHG RXWRIWUDI¿FDQGDZD\IURPIXUQLWXUHDQGGUDSHULHV 7KHVXUIDFHRIWKH+HDWHU,VKRWZKHQLWLVLQXVH<RXQJ children should be watched carefully when they are in the VDPHURRPZKHQWKH+HDWHULVLQXVHDQGWKH\VKRXOG EHWDXJKWWRDYRLGWKHKRWVXUIDFH.HHSDQ\REMHFWVWKDW FDQ EXUQ ZHOO DZD\ IURP WKH +HDWHU DQG REVHUYH WKH UHFRPPHQGHGFOHDUDQFHVWKDWIROORZ DANGER HOT GLASS WILL CAUSE BURNS. E $)ODWRQFRUQHUZDOO '&URVV&RUQHU %5RRP'LYLGHU ()ODWRQZDOO &,VODQG Figure 2 - Possible stove locations. Clearance Requirements Minimum Clearances to Combustible Materials 0HDVXUH VLGH FOHDUDQFHV DV VKRZQ LQ )LJXUHV DQG IURPWKHRXWHUHGJHRIWKHFDVWLURQVWRYHWRS0HDVXUHUHDU FOHDUDQFHVIURPWKHRXWHUPRVWVXUIDFHRIWKHVWHHOUHDUVNLUW The Stardance heater is approved for installation into an alcove constructed of combustible materials to the GLPHQVLRQVDQGFOHDUDQFHVVKRZQRQWKHQH[WSDJH 7KHVDPHFOHDUDQFHVDSSO\LQDVWDQGDUGSDUDOOHOLQVWDOODWLRQ ! • DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed. • WARNING $OZD\VPDLQWDLQUHTXLUHGFOHDUDQFHV DLUVSDFHV WR QHDUE\ FRPEXVWLEOHV WR SUHYHQW ¿UH KD]DUG 'R QRW ¿OODLUVSDFHVZLWKLQVXODWLRQ$OOYHQWLQJFRPSRQHQWV PXVWPDLQWDLQD PP FOHDUDQFHWRFRPEXVWLEOH PDWHULDOV7KH JDV DSSOLDQFH DQG YHQW V\VWHP PXVW EH YHQWHG GLUHFWO\ WR WKH RXWVLGH RI WKH EXLOGLQJ DQG QHYHU EH DWWDFKHG WR D FKLPQH\ VHUYLQJ D VHSDUDWH VROLGIXHORUJDVEXUQLQJDSSOLDQFH Refer to the manufacturer’s instructions included ZLWK WKH YHQWLQJ V\VWHP IRU FRPSOHWH LQVWDOODWLRQ SURFHGXUHV In choosing a location for the stove, consider: • The location of outside walls; • :KHUHDGGLWLRQDOKHDWLVQHHGHG • :KHUHIDPLO\PHPEHUVJDWKHUPRVWRIWHQ • 7KHYHQWV\VWHPUHTXLUHPHQWV NOTE::HGRQRWUHFRPPHQGWKHXVHRIZDOOSDSHUQH[WWR WKLVVWRYH2YHUWLPHUDGLDQWKHDWPD\FDXVHWKHZDOOSDSHU to shrink, or may adversely affect the binders in the wallpaper DGKHVLYH 6 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Parallel Installation Wall Centerline from Floor Minimum Clearance and Flue Centerline Direct Vent Only C L C A D A C L B (IIHFWLYH0LQLPXP Stove Clearances $ PP Wall Thimble PP ++73LSH B PP Centerline PP 'XUD9HQW3LSH C PP Pipe Centerlines D PP Figure 5 - Minimum wall centerline. Wall & Ceiling Clearances )LJXUH 3DUDOOHO LQVWDOODWLRQ PLQLPXP EDFN DQG VLGH FOHDUDQFHVDQGÀXHFHQWHUOLQHV Direct Vent Only D Corner Installation B Minimum Clearance and Flue Centerline B C A A B A Stove Clearances $ PP Pipe Centerlines B PP )LJXUH &RUQHU LQVWDOODWLRQ PLQLPXP FRUQHU FOHDUDQFHV DQGÀXHFHQWHUOLQH 7 $ Rear Wall PP B Minimum Clearance PP C 0LQLPXP$OFRYH+HLJKW PP D 0D[LPXP$OFRYH'HSWK PP Sidewall Clearance PP *QHHGHGIRULQVWDOOLQJ'XUD9HQW0LQLPXP9HQW.LWRU++70LQLPXP9HQW.LW6/3)66. Figure 6 - Dimensions and clearances to ceiling or alcove. Hearth Requirements 7KH 6WDUGDQFH KHDWHU PXVW EH LQVWDOOHG RQ ULJLG ÀRRULQJ When the heater is installed directly on any combustible VXUIDFH RWKHU WKDQ ZRRG ÀRRULQJ D PHWDO RU ZRRG SDQHO H[WHQGLQJWKHIXOOZLGWKDQGGHSWKRIWKHXQLWPXVWEHXVHG DVWKHKHDUWK7KHUHDUHQRRWKHUKHDUWKUHTXLUHPHQWV Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Horizontal Termination *DV6SHFL¿FDWLRQV Model Fuel Control SDDVT 1DW Millivolt Manual 28,000 20,000 7KHYHQWPXVWULVHYHUWLFDOO\DPLQLPXPRI PP RII WKHWRSRIWKHXQLWEHIRUHWKH¿UVWHOERZ7KHKRUL]RQWDOUXQ PD\H[WHQGXSWR¶ P DQGLQFOXGHDYHUWLFDOULVHRIXSWR ¶ P )LJXUH +RUL]RQWDOWHUPLQDWLRQPXVWDOVRPHHW WKHFULWHULDVKRZQLQ)LJXUHVWKURXJK SDDVT LP Millivolt Manual 25,000 21,000 • $SSURYHG YHQW V\VWHPV PXVW WHUPLQDWH DERYH DQG LQFOXGLQJWKHKHDY\OLQHLQ)LJXUH SDVTSC 1DW 6LJQDWXUH Command 28,000 20,000 • SDVTSC LP 6LJQDWXUH Command 7ZRHOERZVPD\EHVXEVWLWXWHGIRUHDFKVLQJOH HOERZ 25,000 21,000 • :LWKDULVHEHWZHHQ¶±¶RQHRUWZRHOERZV PD\EHXVHG Max. Input BTU/h Min. Input BTU/h Gas Inlet and Manifold Pressures Inlet Minimum ZF ZF ,QOHW0D[LPXP ZF ZF Manifold Pressure ZF ZF $LU6KXWWHU6HWWLQJ RSHQ ´RSHQ The installation of your Vermont Castings stove must conform with local codes, or in the absence of local FRGHVZLWKWKH1DWLRQDO)XHO*DV&RGH$16,= 1)3$ ODWHVW HGLWLRQ RU &6$ % ,QVWDOODWLRQ code. (EXCEPTION: Do not derate this appliance IRU DOWLWXGH XS WR P IRU QDWXUDO JDV DQG IHHW P IRU/3*DV0DLQWDLQWKHPDQLIROG SUHVVXUHDWZFIRU1DWXUDO*DVDQGZF for LP Gas. HIGH ELEVATIONS Input ratings are shown in BTU per hour and are FHUWL¿HGZLWKRXWGHUDWLRQIRUHOHYDWLRQVXSWR IHHW P IRUQDWXUDOJDVDQGIHHW P for LP gas above sea level. ,QWKH86$LQVWDOODWLRQVZLWKHOHYDWLRQVDERYH IHHW P IRUQDWXUDOJDVDQGIHHW P IRU LP gas must be in accordance with the current ANSI =1)3$DQGRUORFDOFRGHVKDYLQJMXULVGLFWLRQ 40 39 38 37 36 Vertical Run (in feet) Liquid Propane (Measured from the appliance flue collar to the top of the vent pipe.) Natural 35 34 33 32 31 30 29 28 27 May use up to WKUHH(OERZV 26 25 24 23 1R5HVWULFWRU3ODWH Required 22 21 20 19 18 16 15 14 13 12 11 10 9 8 7 6 5 In Canada, please consult provincial and/or local authorities having jurisdiction for installations at HOHYDWLRQV DERYH IHHW P IRU QDWXUDO JDV DQGIHHW P IRU/3JDV 4 3 2QH (OERZ 1 0 1 2 ! WARNING 8QDFFHSWDEOH 9HQWLQJ&RQ¿JXUDWLRQ 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Horizontal Run (in feet) )LJXUH+RUL]RQWDOYHQWWHUPLQDWLRQZLQGRZ ,PSURSHU LQVWDOODWLRQ DGMXVWPHQW DOWHUDWLRQ VHUYLFH RU PDLQWHQDQFHFDQFDXVHLQMXU\RUSURSHUW\GDPDJH5HIHU to this manual for correct installation and operational proFHGXUHV)RUDVVLVWDQFHRUDGGLWLRQDOLQIRUPDWLRQFRQVXOW DTXDOL¿HGLQVWDOOHUVHUYLFHDJHQF\RUWKHJDVVXSSOLHU 8 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Vertical Termination $YHUWLFDOYHQWV\VWHPPXVWWHUPLQDWHQROHVVWKDQ¶ P DQGQRPRUHWKDQ¶ P DERYHWKHDSSOLDQFHÀXHFROODU$ UHVWULFWRUSODWH VXSSOLHG PXVWEHXVHGZKHUHVSHFL¿HGLQDOO YHUWLFDOO\WHUPLQDWHGYHQWV\VWHPV 5HIHUWR)LJXUH 127( The restrictor plate supplied with the vertical termination VKRXOGEHGLVFDUGHG$GMXVWWKHUHVWULFWRUSODWHDFFRUGLQJWR UHFRPPHQGDWLRQVLQ)LJXUH$YHUWLFDOO\WHUPLQDWHGYHQW V\VWHPPXVWDOVRFRQIRUPWRWKHIROORZLQJFULWHULD Restrictor Plate Adjustment for Extended Pipe Runs The Stardance stove is shipped with a restrictor plate in WKH3DUWV%DJ$GMXVWPHQWVFDQEHPDGHE\ORRVHQLQJWKH DGMXVWPHQWVFUHZWRDOORZWKHUHVWULFWRUSODWHWRVOLGHXSRU GRZQ )LJXUH $JXLGHIRUXVDJHLVVKRZQLQ)LJXUH • 1RPRUHWKDQWKUHHHOERZVPD\EHXVHG 127(6RPHLQVWDOODWLRQVPD\UHTXLUHVRPHDGMXVWPHQW E\WKHLQVWDOOHUIRURSWLPXPÀDPHDSSHDUDQFH2SWLPXP ÀDPHDSSHDUDQFHLVDÀDPHWKDWLVQRWVXEMHFWWRWDOOGLUW\ \HOORZ ÀDPHV SURGXFLQJ VRRW RU ÀDPHV OLIWLQJ RII RI WKH HPEHUEHGSRUWV • 7ZRHOERZVPD\EHVXEVWLWXWHGIRURQHHOERZ 1RPRUHWKDQVL[HOERZVPD\EHXVHG Restrictor Plate Adjustment • 5HPRYHWKHVFUHZLQWKHEDFNZDOORIWKH¿UHER[ • Vent must rise a minimum of 2 feet (305 mm) before RIIVHWLVXVHG • ,QVWDOOUHVWULFWRUSODWHDVVKRZQLQ)LJXUHZLWKFXWRXW RQOHIWVLGH6HFXUHZLWKDGMXVWPHQWVFUHZ • 7HUPLQDWLRQ KHLJKW PXVW FRQIRUP WR URRI FOHDUDQFH DV VSHFL¿HGLQ)LJXUH • 0HDVXUHIURPFHQWHURIVFUHZWRWRSHGJHRIGLYHUWHU )LJXUH WR DGMXVW SODWH DFFRUGLQJ WR JXLGHOLQHV LQ )LJXUH • 7LJKWHQDWWDFKPHQWVFUHZ • ,QVWDOOORJVIROORZLQJORJLQVWDOODWLRQLQVWUXFWLRQV {ä Î În ÎÇ Vertical Run (in feet) (Measure from the appliance flue collar to the top of the vent pipe.) ÎÈ Îx Î{ ÎÎ ÎÓ Î£ $OO9HUWLFDO Terminations in this area Require use of the Restrictor Plate* Restrictor Plate Îä Ó Ón ÓÇ ÓÈ Óx Ó{ ÓÎ Vertical terminations must be within this area ÓÓ Ó£ Óä £ £n £È 8QDFFHSWDEOH 9HQWLQJ&RQ¿JXUDWLRQ £x £{ )LJXUH/RRVHQVFUHZWRDGMXVWUHVWULFWRUSODWH £Î £Ó ££ Examples for Extended Run/Restrictor Plate Settings £ä Vertical 20’ (6 m), 90° elbow, out 8’ P n Ç È x Vertical 11’ P elbow, out 2’ (610 mm) Vertical 40’ (12 m) Vertical 5’ P elbow, out 5’ P ÊÊ{ ** ÊÊÎ Ó Restrictor plate measurement from top of plate to center of screw: £ ä £ Ó 1R5HVWULFWRU3ODWH Î { x È Ç n £ä ££ £Ó £Î £{ £x £È £Ç £n £ Horizontal Run (in feet) Figure 8 - Vertical vent termination window. Óä 23»4´ PP Plate down from center to top of slot of screw to WRSHGJHRI plate Plate down to top of slot 23»8´ PP from center of screw to WRSHGJHRI plate )LJXUH 9 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Vent Termination Clearances :KHQSODQQLQJWKHLQVWDOODWLRQFRQVLGHUWKHORFDWLRQRIWKH YHQW WHUPLQDO DQG FOHDUDQFHV 6RPH RI WKH PRVW FRPPRQ FOHDUDQFHVWRNHHSLQPLQGDUHVKRZQLQ)LJXUH <RXUVWRYHLVDSSURYHGWREHYHQWHGHLWKHUWKURXJKWKHVLGH ZDOORUYHUWLFDOWKURXJKWKHURRI • ++7GRHVQRWUHTXLUHDQ\RSHQLQJIRULQVSHFWLRQRIYHQW SLSH Important: All vent clearances must be maintained. Check your vent termination clearances against Figures 11 and 12. • QO\ ++7 6/3 FRPSRQHQWV RU 'XUD9HQW YHQWLQJ 2 FRPSRQHQWV VSHFL¿FDOO\ DSSURYHG DQG ODEHOHG IRU WKLV VWRYHPD\EHXVHG The vent should be placed so that people cannot be burned E\DFFLGHQWDOO\WRXFKLQJWKHYHQWVXUIDFHVZKHQWKHVWRYH LVRSHUDWLQJ • Minimum clearances between vent pipes and FRPEXVWLEOHPDWHULDOVLVRQH LQFK PP H[FHSW ZKHUHVWDWHGRWKHUZLVH The vent termination should be located where it cannot be GDPDJHGE\VXFKWKLQJVDVDXWRPRELOHGRRUVODZQPRZHUV or snowblowers and it should be located away from areas ZKHUHLWFRXOGEHFRPHEORFNHGE\VQRZHWF • 9HQWLQJ WHUPLQDOV VKDOO QRW EH UHFHVVHG LQWR D ZDOO RU VLGLQJ • +RUL]RQWDO YHQWLQJ PXVW EH LQVWDOOHG RQ D OHYHO SODQH ZLWKRXWDQLQFOLQLQJRUGHFOLQLQJVORSH 6RPHFRQVLGHUDWLRQVDUH • 2EVWUXFWLRQVRULPSHGLPHQWVWRYHQWLQJ • 1HDUE\ FRPEXVWLEOH PDWHULDOV WKDW FRXOG FRPH LQWR FRQWDFWZLWKFRPEXVWLRQH[KDXVWJDVHV • 2WKHU QHDUE\ RSHQLQJV ^ZLWKLQ PP ` WKURXJK ZKLFKH[KDXVWJDVFRXOGUHHQWHUWKHEXLOGLQJ • $OOYHJHWDWLRQZLWKLQ¶ PP WKDWPD\LQWHUIHUHZLWK WKHGUDIW 2WKHU IDFWRUV WKDW LQÀXHQFH ZKHUH WKH LQVWDOODWLRQ ZLOO EH sited include the location of outside walls, where additional heat may be desired in the home, where the family members JDWKHU PRVW UHJXODUO\ DQG SHUKDSV PRVW LPSRUWDQWO\ WKH GLVWDQFHOLPLWDWLRQVRIWKHYHQWLQJV\VWHP There must not be anyREVWUXFWLRQVXFKDVEXVKHVJDUGHQ VKHGVIHQFHVGHFNVRUXWLOLW\EXLOGLQJVZLWKLQIURPWKH IURQWRIWKHWHUPLQDWLRQKRRG 'RQRWORFDWHWHUPLQDWLRQKRRGZKHUHH[FHVVLYHVQRZRULFH EXLOGXSPD\RFFXU%HVXUHWRFKHFNYHQWWHUPLQDWLRQDUHD DIWHUVQRZIDOOVDQGFOHDUWRSUHYHQWDFFLGHQWDOEORFNDJHRI YHQWLQJV\VWHP:KHQXVLQJVQRZEORZHUVPDNHVXUHVQRZ LVQRWGLUHFWHGWRZDUGVYHQWWHUPLQDWLRQDUHD Location of Vent Termination ,WLVLPSHUDWLYHWKHYHQWWHUPLQDWLRQEHORFDWHGREVHUYLQJWKH PLQLPXPFOHDUDQFHVDVVKRZQLQWKLVPDQXDO IMPORTANT The horizontal termination must not be recessed into the exterior wall or siding. Horizontal vent runs must be level toward the vent termination. Clearances around the vent termination must be maintained. For installations using DuraVent pipe, parallel installations with minimum wall clearance have restricted access for connecting the Horizontal Vent Cap straps to the vent pipe. See the maker’s instructions for recommended installation procedures. 10 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H A D V E L C B V F B Fixed Closed V B V Ope rable Operable V Fixed Closed B B B V J I A CFM145a V VENT TERMINATION X AIR SUPPLY INLET M X X K V AREA WHERE TERMINAL IS NOT PERMITTED CANADIAN INSTALLATIONS1 US INSTALLATIONS2 $ &OHDUDQFHDERYHJUDGHYHUDQGDSRUFKGHFN FP or balcony FP % &OHDUDQFHWRZLQGRZRUGRRUWKDWPD\EH opened FP IRUDSSOLDQFHV%78K N: FP IRUDSSOLDQFHV%78K N: FP IRUDSSOLDQFHV!%78K N: DQG%78K N: FP IRUDSSOLDQFHV!%78K N: DQG %78K N: FP IRUDSSOLDQFHV!%78K N: FP IRUDSSOLDQFHV!%78K N: & &OHDUDQFHWRSHUPDQHQWO\FORVHGZLQGRZ PP UHFRPPHQGHGWRSUHYHQWZLQGRZ condensation PP UHFRPPHQGHGWRSUHYHQWZLQGRZ condensation ' 9HUWLFDOFOHDUDQFHWRYHQWLODWHGVRI¿WORFDWHG PP DERYHWKHWHUPLQDOZLWKLQDKRUL]RQWDOGLVWDQFH of 2' (610 mm) from the center line of the terminal PP ( &OHDUDQFHWRXQYHQWLODWHGVRI¿W PP PP ) &OHDUDQFHWRRXWVLGHFRUQHU VHHQH[WSDJH VHHQH[WSDJH * &OHDUDQFHWRLQVLGHFRUQHU VHHQH[WSDJH VHHQH[WSDJH + &OHDUDQFHWRHDFKLQVLGHRIFHQWHUOLQH H[WHQGHGDERYHPHWHUUHJXODWRUDVVHPEO\ FP ZLWKLQDKHLJKWRI P DERYHWKH PHWHUUHJXODWRUDVVHPEO\ FP ZLWKLQDKHLJKWRI P DERYHWKH PHWHUUHJXODWRUDVVHPEO\ , &OHDUDQFHWRVHUYLFHUHJXODWRUYHQWRXWOHW 3' (91cm) 3' (91cm) - &OHDUDQFHWRQRQPHFKDQLFDODLUVXSSO\LQOHW WREXLOGLQJRUWKHFRPEXVWLRQDLULQOHWWRDQ\ other appliance FP IRUDSSOLDQFHV%78K N: FP IRUDSSOLDQFHV%78K N: FP IRUDSSOLDQFHV!%78K N: DQG%78K N: FP IRUDSSOLDQFHV!%78K N: DQG %78K N: FP IRUDSSOLDQFHV!%78K N: FP IRUDSSOLDQFHV!%78K N: . &OHDUDQFHWRPHFKDQLFDODLUVXSSO\LQOHW P FP DERYHLIZLWKLQ P KRUL]RQWDOO\ / &OHDUDQFHDERYHSDYHGVLGHZDONRUSDYHG driveway located on public property P 0 &OHDUDQFHXQGHUYHUDQGDSRUFKGHFNRU balcony FP P † ‡ † FP ‡ 1 &OHDUDQFHDERYHDURRIVKDOOH[WHQGDPLQLPXPRI´ PP DERYHWKHKLJKHVWSRLQWZKHQLWSDVVHVWKURXJKWKHURRIVXUIDFHDQGDQ\RWKHUREVWUXFWLRQ ZLWKLQDKRUL]RQWDOGLVWDQFHRI´ PP Figure 11 - Vent termination clearances. ,QDFFRUGDQFHZLWKWKHFXUUHQW&6$%,QVWDOODWLRQ Codes ,QDFFRUGDQFHZLWKWKHFXUUHQW$16,=1)3$ 1DWLRQDO)XHO*DV&RGHV $YHQWVKDOOQRWWHUPLQDWHGLUHFWO\DERYHDVLGHZDONRU SDYHGGULYHZD\ZKLFKLVORFDWHGEHWZHHQWZRVLQJOH IDPLO\GZHOOLQJVDQGVHUYHVERWKGZHOOLQJV ‡2QO\SHUPLWWHGLIYHUDQGDSRUFKGHFNRUEDOFRQ\LVIXOO\ RSHQRQDPLQLPXPVLGHVEHQHDWKWKHÀRRU 11 NOTE: /RFDO FRGHV RU UHJXODWLRQV PD\ UHTXLUH GLIIHUHQW FOHDUDQFHV 7KHVSHFLDOYHQWLQJV\VWHPXVHGRQ'LUHFW9HQW)LUHSODFHV DUH FHUWL¿HG DV SDUW RI WKH DSSOLDQFH ZLWK FOHDUDQFHV WHVWHGDQGDSSURYHGE\WKHOLVWLQJDJHQF\ ++7 DVVXPHV QR UHVSRQVLELOLW\ IRU WKH LPSURSHU SHUIRUPDQFHRIWKHDSSOLDQFHZKHQWKHYHQWLQJV\VWHP GRHVQRWPHHWWKHVHUHTXLUHPHQWV Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Alcove Applications* Inside Corner Outside Corner D C G= Combustible 6" (152 mm) G V Noncombustible 2" (51 mm) V V O F Balcony with perpendicular side wall Balcony with no side wall C F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) E E = Min. 2” (51 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min. M M V V P M= Combustible & Noncombustible 12" (305 mm) Combustible & Noncombustible M = 12" (305 mm) P = 6” (152 mm) RI Caps D0LQ C0D[ 1 3’ (914 mm) ;'$FWXDO 2 ¶ P ;'$FWXDO 3 ¶ P ;'$FWXDO 4 ¶ P ;'$FWXDO D0LQ RI7HUPLQDWLRQFDSV[ C0D[ WHUPLQDWLRQFDSV ['$FWXDO *NOTE:7HUPLQDWLRQLQDQDOFRYHVSDFH VSDFHVRSHQRQO\RQRQHVLGHDQGZLWKDQRYHUKDQJ LVSHUPLWWHGZLWKWKHGLPHQVLRQVVSHFL¿HGIRUYLQ\ORU QRQYLQ\OVLGLQJDQGVRI¿WV7KHUHPXVWEHD¶ PP PLQLPXPEHWZHHQWHUPLQDWLRQFDSV$OOPHFKDQLFDODLULQWDNHVZLWKLQ¶ P RID WHUPLQDWLRQFDSPXVWEHDPLQLPXPRI¶ PP EHORZWKHWHUPLQDWLRQFDS$OOJUDYLW\DLULQWDNHVZLWKLQ¶ PP RIDWHUPLQDWLRQFDSPXVW EHDPLQLPXPRI¶ PP EHORZWKHWHUPLQDWLRQFDS Figure 12 - Termination clearances. 12 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Approved Vent System Components 7KH6WDUGDQFHKHDWHUPXVWEHYHQWHGWRWKHRXWGRRUVWKURXJK DQ DGMDFHQW H[WHULRU ZDOO RU WKURXJK WKH URRI7KH YHQWLQJ V\VWHPPXVWEHFRPSULVHGRIWKHDSSURSULDWHOLVWHGYHQWLQJ FRPSRQHQWVVSHFL¿HGRQWKLVSDJH7KHVHSDUWVDUHDYDLODEOH IURP'XUD9HQW&RUSRUDWLRQRU\RXU9HUPRQW&DVWLQJV'HDOHU 6HH )LJXUH IRU GLPHQVLRQV UHOHYDQW WR WKH VWDQGDUG PLQLPXPYHQWNLWV HHT Components* DuraVent Components 6WDUWHU 3LSH $VVHPEO\ LQFO LQQHU RXWHU sections) (OERZ%ON (OERZ*DO 6WUDLJKW%ON 6WUDLJKW%ON ± »8$GMXVWDEOH6WUDLJKW6HFWLRQ 5 6WUDLJKW 6WUDLJKW '9$$'3 '9$(% '9$( '9$% '9$% '9$$% '9$ '9$% 6/3+RUL]RQWDO7HUPLQDWLRQ.LW 7HUPLQDWLRQ &DS6/3%.6/3%.6/3$%. 6/3%.6/3:7%. &&6/3 6/36.%. 6WRYH$GDSWHU.LW ,QFOXGHV RI)OH[ DGDSWHUVZDOOWKLPEOHPDVRQU\DQG=& ÀDVKLQJ'$&DSDQG)DVWHQHUV /,1.6729( 7UDSH]RLG7HUPLQDWLRQ.LW ´´ 6/375$3 9LQ\O6LGLQJ6KLHOG 7UDSH]RLG7HUPLQDWLRQ.LW ´´ 6/375$3 6QRUNHO7HUPLQDWLRQ± '9$61. 5HDU9HQW7HUPLQDWLRQ.LW 6/3597. 6QRUNHO7HUPLQDWLRQ± '9$61. 9HUWLFDO7HUPLQDWLRQFDS+LJK:LQG (includes storm collar) 6/379+: Wall Strap '9$:6 &DWKHGUDO&HLOLQJ6XSSRUW%R[ '9$&6 Decorative Wall Thimble Cover 6/3:7%. Storm Collar '9$6& 'HFRUDWLYHFHLOLQJ¿UHVWRSEODFN 6/3'&)%. )LUHVWRS6SDFHU '9$)6 &DWKHGUDOFHLOLQJVXSSRUWEODFN 6/3&&6%. )ODVKLQJ '9$) PP SLSHOHQJWKEODFN 6/3%. )ODVKLQJ '9$) PP SLSHOHQJWKEODFN 6/3%. Wall Thimble 3LSHOHQJWKEODFN 6/3%. Wall Thimble '9$:7 3LSHOHQJWKEODFN 6/3%. Wall Thimble Cover (Brass) 3937.9 PP SLSHOHQJWKEODFN 6/3%. :DOO)LUHVWRS '9$:)6 3LSHOHQJWKEODFN 6/3%. $WWLF,QVXODWLRQ6KLHOG '9$,6 PP WHOHVFRSLQJSLSH H[WHQVLRQEODFN 6/3$%. &R/LQHDU9HQW$GDSWHU '9$*&/ WHOHVFRSLQJSLSHH[WHQVLRQEODFN 6/3$%. GHJUHHHOERZEODFN 6/3%. GHJUHHHOERZEODFN 6/3%. 5DGLDQFH6WDUGDQFH2[IRUG6/3DGDSWHU CCSLP )UHHVWDQGLQJ'UDIW+RRG$GDSWHU )6'+$*6/3 6/6QRUNHO&DS ,QFOXGHVSDLURI¿UHVWRSV 6/.61.' 6WUDLJKW '9$% 6WUDLJKW '9$ +RUL]RQWDO9HQW&DS Wall Plate &&6/3DGDSWHULVUHTXLUHGZKHQXVLQJ++7FRPSRQHQWV Wall Thimble Cover (Brass) :DOO)LUHVWRS $WWLF,QVWDOODWLRQ6KLHOG '9$+& '9$'& '9$966 '9$:7 3937.9 '9$:)6 '9$,6 &R/LQHDU9HQW$GDSWHU '9$*&/ 6WHHO&KLPQH\&RQY.LW$ '9$.&$ 6WHHO&KLPQH\&RQY.LW% '9$.&% 6WHHO&KLPQH\&RQY.LW& ± '9$.&& 0DVRQU\&KLPQH\&RQYHUVLRQ.LW '9$.0& 9HUWLFDO7HUPLQDWLRQ&DS +LJK:LQG '9$9&+ 9HUWLFDO7HUPLQDWLRQ&DS /RZ3UR¿OH '9$9& $OO'XUD9HQW6WUDLJKWYHQWSLSHVHFWLRQVKDYHDQHWOHQJWK PP OHVV WKDQ WKH QRPLQDO GLPHQVLRQ LH D PP 6WUDLJKWSLSHVHFWLRQKDVDQHIIHFWLYHOHQJWKRI PP 13 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Assembly & Installation Tools Required • Phillips screwdriver (stub) • 8WLOLW\NQLIH • 0HWDOGULOOELWVL]H PP • )ODWEODGHVFUHZGULYHU • Power drill • 5HFLSURFDWLQJVDZ • :UHQFK • :UHQFK Parts Bag Contents: • /3&RQYHUVLRQ.LW • Three (3) Vent Screws • Two (2) Switch bracket screws • :RRGKDQGOHZLQVHUWOLIWHU KDQGOHIRURSHUDEOHGRRU • Restrictor Plate • 6WDUWHUSLSH • 2Q2IIVZLWFKKRXVLQJDQGZLULQJKDUQHVV • 7KUHH 3KLOOLSVURXQGKHDGEROWV±[ • 2QH 7XEHRI9HQW*DVNHW&HPHQW • +RPHRZQHU¶V,QVWDOODWLRQDQG2SHUDWLQJ0DQXDO Unpack Stove 8VLQJ WKH ZUHQFK UHPRYH WKH ODJ EROWV LQVWDOOHG WKURXJKWKHVKLSSLQJEUDFNHWVDQGLQWRWKHVNLG2QFHWKH ODJEROWVDUHUHPRYHGUHPRYHWKHVKLSSLQJEUDFNHWVIURP WKHVWRYHXVLQJZUHQFKRUVRFNHWDQGLQVWDOOOHJOHYHOOHUV ORFDWHGLQWKHPDQXDOEDJRQWRWKHOHJV ! WARNING 7KLVDSSOLDQFHLVHTXLSSHGZLWKDWKUHHSURQJ JURXQGHG SOXJIRU\RXUSURWHFWLRQDJDLQVWVKRFNKD]DUGDQGVKRXOG EHSOXJJHGGLUHFWO\LQWRDSURSHUO\JURXQGHGWKUHHSURQJ UHFHSWDFOH 'R QRW FXW RU UHPRYH WKH JURXQGLQJ SURQJ IURPWKLVSOXJ Install the Optional Fan – SDDVT models (Millivolt Only See page 27 for SC Models) ,I\RXDUHLQVWDOOLQJWKHRSWLRQDOFRQYHFWLRQ)DQ.LW ). FRQWLQXHKHUH,WLVHDVLHVWWRLQVWDOOIDQNLWEHIRUH FRQQHFWLQJJDVOLQH Snapstat Bracket 6QDSVWDW ([WHQVLRQ $VVHPEO\ 1RW8VHG2Q Stardance Rheostat $VVHPEO\ Blower $VVHPEO\ Figure 15)DQNLWFRPSRQHQWV 5HPRYHWKHUHDUVNLUWLQVHUWSDQHODWWKHERWWRPRIWKH 5HDU6NLUW )LJXUH DQGIDVWHQWKHEORZHU DVVHPEO\ WRWKH¿UHER[EDFNZLWKWKHWZR3KLOOLSVSDQKHDGEROWV RULJLQDOO\LQVWDOOHGLQWKH¿UHER[EDFN µ¶)LJXUH $WWDFK WKH VQDSVWDW DVVHPEO\ WR WKH VQDSVWDW EUDFNHW ZLWK WZR VKHHWPHWDO VFUHZV µ¶ )LJXUH $WWDFK WKH VQDSVWDW EUDFNHW WR WKH VWRYH ZLWK D KH[KHDG EROW SDVVLQJWKURXJKWKHEUDFNHWDQGLQWRWKHVWRYHEDVH µ¶ )LJXUH 7KHUKHRVWDWFRQWUROVZLWFKDWWDFKHVWRWKHOHIWVLGHRIWKH YDOYHEUDFNHWDWWKHIURQWRIWKHVWRYH )LJXUH Rear Skirt Sheet Metal Screws Rear Skirt Insert Figure 16 - Remove rear shroud. 7KHIDQNLWLQFOXGHVD%ORZHU$VVHPEO\DQGD5KHRVWDW $VVHPEO\FRQQHFWHGE\DFDEOH )LJXUH 7KH%ORZHU $VVHPEO\PRXQWVWRWKHERWWRPUHDURIWKHVWRYHDQGWKH 5KHRVWDWPRXQWVWRWKHYDOYHFRYHUSODWH7KHDVVHPEO\ includes a ‘snapstat’ which automatically turns the fan 2Q RU 2II DERYH RU EHORZ DSSUR[LPDWHO\ 7KH 5KHRVWDW DOVR SURYLGHV D UDQJH RI IDQ VSHHG VHWWLQJV IURP2II ZKLFKRYHUULGHVWKHVQDSVWDWIXQFWLRQ WR+LJK 8QSDFNDQGLQVSHFWWKH%ORZHUDVVHPEO\&RQ¿UPWKDW WKHIDQVSLQVIUHHO\ 14 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Star Washer Sheet Metal Screws 2 1 Phillips 3DQ+HDG Bolts Snapstat ´± +H[%ROW Star Washer 3 Snapstat Bracket NOTE:6KRZQZLWKRXWVKHOOIRUFODUL¿FDWLRQ )LJXUH$WWDFKEORZHUDVVHPEO\DQGVQDSVWDW Rheostat Rheostat 5HWDLQLQJ&ROODU 5KHRVWDW.QRE Figure 18$WWDFKWKHIDQUKHRVWDW 5HPRYH UHWDLQLQJ QXW IURP VKDIW RI UKHRVWDW LI preinstalled) ,QVHUWWKHUKHRVWDWWKURXJKWKHKROHLQWKHEDFNRIWKHOHIW VLGHRIWKHYDOYHEUDFNHWDOLJQLQJWKHORFDWRUSLQZLWKWKH VPDOOHUKROHLQWKDWEUDFNHW 7KUHDGWKHUHWDLQLQJQXWRQWRWKHVKDIWRIWKHUKHRVWDW WLJKWHQLQJZLWKDZUHQFK'RQRWRYHUWLJKWHQ $WWDFKWKHFRQWURONQREWRWKHUKHRVWDWVKDIW 8VH WKH ZLUH WLH WR VHFXUH WKH IDQ DQG UKHRVWDW ZLUH KDUQHVVHVWRJHWKHU 15 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Venting System Assembly ! WARNING $OZD\V PDLQWDLQ PLQLPXP FOHDUDQFHV DURXQG YHQW V\VWHPV 5HDU7RS 9HQW 9HUWLFDO 6LGH ZDOO +RUL]RQWDO VHFWLRQVRIWKLVYHQWV\VWHPUHTXLUHDPLQLPXPRI´ PP FOHDUDQFHVWRFRPEXVWLEOHVDWWKHWRSRIWKHÀXHDQG ´ PP FOHDUDQFHDWWKHVLGHVDQGERWWRPXQWLOWKHÀXH SHQHWUDWHVWKHRXWVLGHZDOO$PLQLPXP´FOHDUDQFHDOO DURXQGWKHÀXHLVDFFHSWDEOHDWWKLVSRLQWRISHQHWUDWLRQ,I YHUWLFDOULVHLV»IHHW P RUKLJKHUZKHQWRSYHQWLQJ WKH FOHDUDQFH WR FRPEXVWLEOHV LV ´ RQ DOO VLGHV RI WKH KRUL]RQWDOUXQ)259(57,&$/581621/<PDLQWDLQD ´ PP PLQLPXPFOHDUDQFHWRDOOVLGHV'RQRWSDFN WKHRSHQDLUVSDFHVDURXQGWKHVWRYHRUÀXHZLWKLQVXODWLRQ RURWKHUPDWHULDOV$Q\KRUL]RQWDOUXQPXVWKDYHD´ULVH IRUHYHU\RQH IRRWRIUXQWRZDUGVWKHYHQWWHUPLQDWLRQ 1HYHUUXQWKHYHQWOHYHORUGRZQ ! WARNING )DLOXUHWRIROORZWKHVHLQVWUXFWLRQVPD\FUHDWHDSRVVLEOH ¿UHKD]DUGDQGZLOOYRLGWKHZDUUDQW\ ! 7KHVHPRGHOVDUHDSSURYHGWRXVH++7GLUHFWYHQWSLSH FRPSRQHQWV DQG ++7 WHUPLQDWLRQ NLWV DQG 'XUD9HQW FRPSRQHQWV1RRWKHUYHQWLQJV\VWHPFRPSRQHQWVPD\ EHXVHG • +RUL]RQWDOUXQVPXVWEHVXSSRUWHGHYHU\IHHW PP XVLQJZDOOVWUDSV9HUWLFDOUXQVPXVWEHVXSSRUWHGHYHU\ IHHW P XVLQJZDOOVWUDSV6OLSZDOOVWUDSVORRVHO\ RQWRSLSH$WWDFKVWUDSVWRIUDPLQJPHPEHUVXVLQJQDLOV RUVFUHZV7LJKWHQQXWEROWWRVHFXUHSLSH • 7KH VWRYH DQG YHQWLQJ V\VWHP VKRXOG EH LQVSHFWHG EHIRUH LQLWLDO XVH DQG DW OHDVW DQQXDOO\ E\ D TXDOL¿HG ¿HOGVHUYLFHSHUVRQ,QVSHFWWKHH[WHUQDOYHQWFDSRQD UHJXODU EDVLV WR PDNH VXUH WKDW QR GHEULV LV LQWHUIHULQJ ZLWKWKHDLUÀRZ,QVSHFWHQWLUHYHQWLQJV\VWHPWRHQVXUH SURSHUIXQFWLRQ CAUTION $OO ++7 'LUHFW 9HQW 6WRYHV KDYH EHHQ WHVWHG DQG DSSURYHGWR$16,&6$6WDQGDUGVDQGZLOORSHUDWHVDIHO\ ZKHQLQVWDOOHGLQDFFRUGDQFHZLWKWKLVLQVWUXFWLRQPDQXDO 5HDGDOOLQVWUXFWLRQVEHIRUHVWDUWLQJLQVWDOODWLRQWKHQIROORZ WKHVHLQVWUXFWLRQVFDUHIXOO\WRPD[LPL]HVWRYHSHUIRUPDQFH DQGVDIHW\5HSRUWGDPDJHGSDUWVWR\RXUGHDOHU ! • WARNING $Q\FRPPRQYHQWLQJRIWKLVJDVDSSOLDQFHZLWKRWKHUJDV DSSOLDQFHVLVQRWDOORZHG Outside Wall Finishing Material (Vinyl Siding, etc.) )LJXUH7HUPLQDWLRQFDSRQZDOO Before You Start 3ODQ\RXULQVWDOODWLRQ6HWWKHVWRYHLQSODFHDQGVXUYH\KRZ WREHVWYHQWWKHXQLW6HOHFWWKHDSSURSULDWHWHUPLQDWLRQNLW DQGYHQWSLSHIRUWKHLQVWDOODWLRQ5HDGWKHVHLQVWUXFWLRQVDQG WKHVWRYH+RPHRZQHU¶V0DQXDOEHIRUHEHJLQQLQJLQVWDOODWLRQ $IWHUYHQWFRQ¿JXUDWLRQKDVEHHQGHFLGHGEHJLQDWWDFKLQJ SLSHWRXQLW ,WHPVUHTXLUHGIRULQVWDOODWLRQ Important Safety Information 7KHWHUPLQDWLRQFDS0867EHYHQWHGGLUHFWO\WRWKHRXWVLGH 7KHWHUPLQDWLRQNLW08671(9(5EHFRQQHFWHGWRDFKLPQH\ ÀXH V VHUYLFLQJDVHSDUDWHVROLGIXHOEXUQLQJDSSOLDQFHRU DQ\RWKHUDSSOLDQFHV • • 16 7HUPLQDWLRQFDS0867127EHUHFHVVHGLQWRDZDOO VHH )LJXUH The installation must conform with local codes or in the DEVHQFHRIORFDOFRGHVZLWKWKH1DWLRQDO)XHO*DV&RGH $16, = LQ WKH 8QLWHG 6WDWHV RU ZLWK WKH FXUUHQW LQVWDOODWLRQFRGH&6$% LQ&DQDGD Tools: 3KLOOLSVVFUHZGULYHU 6DZDQGRUVDEHUVDZ 0HDVXULQJ7DSH Pliers +DPPHU /HYHO (OHFWULFGULOODQGELWV Square Building Supplies: )UDPLQJPDWHULDOV :DOO¿QLVKLQJPDWHULDOV &DXONLQJ0DWHULDO QRQFRPEXVWLEOH Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 ! WARNING 5HIHUWRSDJHVDQGRIWKLVPDQXDOIRUWKHPLQLPXP DQG PD[LPXP YHQWLQJ UHTXLUHPHQWV RI \RXU VWRYH DQG IRU DSSURYHG KRUL]RQWDO YHQW WHUPLQDWLRQ ORFDWLRQV SULRU WRLQVWDOODWLRQ)DLOXUHWRGRVRPD\FDXVH¿UHKD]DUG ENT CEM ! WARNING $Q\KRUL]RQWDOUXQPXVWKDYHD´ULVHIRUHYHU\RQH IRRWRIUXQWRZDUGVWKHYHQWWHUPLQDWLRQ1HYHUDOORZWKH YHQWSLSHWRUXQGRZQ7KLVFRXOGFDXVHKLJKWHPSHUDWXUHV DQGPD\SUHVHQWD¿UHKD]DUG ! WARNING Termination cap must be positioned so the embossed DUURZLVSRLQWHGXS General Information The Stardance is approved for installation only with the YHQW FRPSRQHQWV OLVWHG LQ WKH Approved Vent System &RPSRQHQWV VHFWLRQ LQ WKLV PDQXDO )ROORZ WKH YHQW FRPSRQHQWLQVWUXFWLRQVH[DFWO\ )LJXUH&RQQHFWWKHLQQHUVWDUWHUZLWKWKHQH[WVHFWLRQRI inner vent pipe. $WWDFKWKH,QQHU9HQW$VVHPEO\WRWKHVWRYH 3ODFHDEHDGRIPLOOSDFNFDXONDURXQGWKHLQVLGHRI WKHFDVWVWDUWHUFROODU,QVHUWWKHRXWHUDGDSWHULQWR WKHFDVWRXWHUVWDUWLQJFROODUDQGSUHVVGRZQ¿UPO\ ,QVWDOOWKH&&6/32XWHU$GDSWHU3LSH 3ODFH D EHDG RI PLOOSDFN FDXON DURXQG WKH FULPSHGHQGRIWKHVWDUWHUFROODURQWKHVWRYH$WWDFKWKH 6/3SLSHWRWKHDGDSWHUDQGVHFXUHE\DOLJQLQJDGDSWHU DQGSLSHVHDPVSUHVVLQJGRZQ¿UPO\XQWLOSLSHVWRSV DQGWZLVWLQJWRORFNLQWRSODFH )LJXUH )RU86LQVWDOODWLRQV7KHYHQWLQJV\VWHPPXVWFRQIRUPZLWK ORFDOFRGHVDQGRUWKHFXUUHQW1DWLRQDO)XHO*DV&RGH$16, =1)3$ )RU&DQDGLDQLQVWDOODWLRQV7KHYHQWLQJV\VWHPPXVWFRQIRUP WRWKHFXUUHQW&6$%LQVWDOODWLRQFRGH Install the Vent Adapter Pipe (HHT SLP Vent Components) $WWDFK,QQHU6WDUWHU3LSH IRXQGLQWKH3DUWV%DJ WRWKH QH[WVHFWLRQRILQQHUSLSH 5XQDEHDGRIVHDODQWDERXWIURPWKHXSSHUHQGRI WKH,QQHUVWDUWHUSLSHDQGMRLQWKHWZRVHFWLRQVWRJHWKHU Drill three pilot holes into the Inner Starter and secure WKHDVVHPEO\ZLWKWKUHHVKHHWPHWDOVFUHZV )LJXUH 'U\ ¿W WKH ,QQHU 3LSH DVVHPEO\ WR WKH VWRYH IRU WKH SXUSRVHRIGHWHUPLQLQJWKHFHQWHUOLQHRIWKHSLSHRQWKH ZDOO )LJXUH$WWDFKLQQHUDVVHPEO\WRÀXHFROODU 6LGH:DOO7HUPLQDWLRQV'U\¿WWKHRXWHUHOERZZLWKWKH YHUWLFDORXWHUYHQWDQGFRQ¿UPWKHFHQWHUOLQHDOLJQPHQW ZLWKWKHZDOOWKLPEOHRSHQLQJ 17 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Assemble Slip Sections 7KHRXWHUÀXHRIWKHVOLSVHFWLRQVKRXOGVOLGHRYHUWKHRXWHU ÀXH RI WKH SLSH VHFWLRQ DQG LQWR LQQHU ÀXH WKH ODVW SLSH VHFWLRQ )LJXUH 6OLGHWRJHWKHUWRWKHGHVLUHGOHQJWKPDNLQJVXUHWKDWD RXWHU ÀXH RYHUODS LV PDLQWDLQHG EHWZHHQ WKH SLSH VHFWLRQ DQGVOLSVHFWLRQ 7KHSLSHDQGVOLSVHFWLRQQHHGWREHVHFXUHGE\GULYLQJWZR LQVFUHZVWKURXJKWKHRYHUODSSLQJSRUWLRQVRIWKHRXWHU ÀXHVXVLQJWKHSLORWKROHV )LJXUH 7KLV ZLOO VHFXUH WKH VOLS VHFWLRQ WR WKH GHVLUHG OHQJWK DQG SUHYHQW LW IURP VHSDUDWLQJ 7KH VOLS VHFWLRQ FDQ WKHQ EH DWWDFKHGWRWKHQH[WSLSHVHFWLRQ ,IWKHVOLSVHFWLRQLVWRRORQJWKHLQQHUDQGRXWHUÀXHVRIWKH VOLSVHFWLRQFDQEHFXWWRWKHGHVLUHGOHQJWK ! WARNING 5LVNRI)LUH([SORVLRQDO NOT break seals on slip secWLRQV8VHFDUHZKHQUHPRYLQJWHUPLQDWLRQFDSIURPVOLS SLSH,IVOLSVHFWLRQVHDOVDUHEURNHQGXULQJUHPRYDORIWKH WHUPLQDWLRQFDSYHQWPD\OHDN )LJXUH6FUHZVLQWR6OLS6HFWLRQ Secure the Vent Sections 9HUWLFDOVHFWLRQVRI6/3SLSHPXVWEHVXSSRUWHGHYHU\IW 7KH6/3¿UHVWRSLQFOXGHVWDEVWKDWPD\EHXVHGWRVHFXUH YHUWLFDOVHFWLRQV The vent support or plumber’s strap (spaced 120° apart) may be used to secure the vertical sections of pipe (see )LJXUH +RUL]RQWDOVHFWLRQVRIYHQWPXVWEHVXSSRUWHGHYHU\IWZLWK DYHQWVXSSRUWRUSOXPEHU¶VVWUDS VHH)LJXUH ! CORRECT INCORRECT WARNING 5LVN RI )LUH([SORVLRQ$VSK\[LDWLRQ ,PSURSHU VXSSRUW PD\DOORZYHQWWRVDJDQGVHSDUDWH8VHYHQWUXQVXSSRUWV DQGFRQQHFWYHQWVHFWLRQVSHULQVWDOODWLRQLQVWUXFWLRQV'2 127DOORZYHQWWRVDJEHORZFRQQHFWLRQSRLQWWRDSSOLDQFH Figure 22 - Make sure the seams are not aligned to prevent unintentional disconnection. )LJXUH6OLS6HFWLRQ3LORW+ROHV 18 Figure 25 - Securing Vertical Pipe Sections Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Horizontal Termination Cap ! WARNING 5LVNRI)LUH7KHWHOHVFRSLQJÀXHVHFWLRQRIWKHWHUPLQDWLRQ FDS0867EHXVHGZKHQFRQQHFWLQJYHQW • ´ PP PLQLPXP RYHUODS RI YHQW DQG WHOHVFRSLQJÀXHVHFWLRQLVUHTXLUHG )DLOXUHWRPDLQWDLQRYHUODSPD\FDXVHRYHUKHDWLQJDQG ¿UH Figure 26 - Securing Horizontal Pipe Sections Disassemble Vent Sections To disassemble any two pieces of pipe, rotate either section )LJXUH VR WKDW WKH VHDPV RQ ERWK SLSH VHFWLRQV DUH DOLJQHG )LJXUH 7KH\FDQWKHQEHFDUHIXOO\SXOOHGDSDUW Note: For horizontal vent runs through a combustible wall and framing dimensions, refer to appliance installation manual. Install the Horizontal Termination Cap $WWDFKVOLSVHFWLRQRIFDSWRODVWYHQWVHFWLRQ0DLQWDLQ1»2 RYHUODSEHWZHHQVOLSDQGYHQWVHFWLRQV Note: For installations using black pipe, slide the decorative wall thimble over the last vent pipe before connecting the termination to the pipe. When this connection has been made, slide the wall thimble up to the interior wall surface and attach with screws provided. 6HFXUHWHUPLQDWLRQFDSWRH[WHULRUZDOOXVLQJSURYLGHGKROHV DQGIDVWHQHUV 9HQW WHUPLQDWLRQ PXVW QRW EH UHFHVVHG LQ WKH ZDOO 6LGLQJ PD\EHEURXJKWWRWKHHGJHRIWKHFDSEDVH )LJXUH5RWDWH6HDPVIRU'LVDVVHPEO\ ! CAUTION Risk of Burns! Local codes may require installation of a WHUPLQDWLRQ JXDUG WR SUHYHQW DQ\WKLQJ RU DQ\RQH IURP WRXFKLQJWKHKRWFDS )ODVKDQGVHDODVDSSURSULDWHIRUVLGLQJPDWHULDODWRXWVLGH HGJHVRIFDS :KHQLQVWDOOLQJDKRUL]RQWDOWHUPLQDWLRQFDSIROORZWKHFDS ORFDWLRQ JXLGHOLQHV DV SUHVFULEHG E\ FXUUHQW$16,= DQG&$1&*$%LQVWDOODWLRQFRGHV Figure 28 - Align and Disassemble Vent Sections 19 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Divert Roof Run-off ++7UHFRPPHQGVZKHUHH[FHVVLYHZDWHUUXQRIILVSRVVLEOH XVHRIRQHRIWKHWZRRSWLRQVVKRZQLQ)LJXUHWRSUHYHQW ZDWHU UXQQLQJ RII WKH URRI DQG RQWRLQWR WKH KRUL]RQWDO WHUPLQDWLRQFDS Vent Opening for Combustible Walls (244 mm) (244 mm) 6WRYH+HDUWK )UDPLQJ'HWDLO Opening for Noncombustible Wall Install gutter (190 mm) 6WRYH+HDUWK )LJXUH/RFDWH9HQW2SHQLQJRQ:DOO 6HFXUH¿UHVWRSWRWKHLQVLGHIUDPHFHQWHULQWKH[ YHQWRSHQLQJ 3ODFHVWRYHLQWRSRVLWLRQ0HDVXUHWKHYHUWLFDOKHLJKW ; UHTXLUHGIURPWKHEDVHRIWKHÀXHFROODUVWRWKHFHQWHURI WKHZDOORSHQLQJ)LJXUH Install L-shaped diverter )LJXUH/RFDWH9HQW2SHQLQJRQ:DOO X Vertical Side Wall Installation: 127( 5HIHU WR )LJXUHV WKUX IRU UHVWULFWRU SODWH adjustments for vertical vent runs. /RFDWH YHQW RSHQLQJ RQ WKH ZDOO ,W PD\ EH QHFHVVDU\ WR ¿UVW SRVLWLRQ WKH VWRYH DQG PHDVXUH WR REWDLQ KROH ORFDWLRQ'HSHQGLQJRQZKHWKHUWKHZDOOLVFRPEXVWLEOH RU QRQFRPEXVWLEOH FXW RSHQLQJ WR VL]H )LJXUH )RU FRPEXVWLEOH ZDOOV ¿UVW IUDPH LQ RSHQLQJ &RPEXVWLEOH:DOOV&XWD+[: [PP KROH WKURXJKWKHH[WHULRUZDOODQGIUDPHDVVKRZQ)LJXUH 1RQFRPEXVWLEOH :DOOV +ROH RSHQLQJ PXVW EH PP LQGLDPHWHU 127(:KHQXVLQJÀH[YHQWWKHRSHQLQJZLOOKDYHWR EHPHDVXUHGDFFRUGLQJWRWKH´ PP ULVHLQ´ PP YHQWUXQ )LJXUH9HUWLFDO+HLJKW5HTXLUHPHQWV 8VLQJ DSSURSULDWH OHQJWK RI SLSH VHFWLRQ V DWWDFK WR VWRYHE\WZLVWLQJFROODU 0HDVXUHWKHKRUL]RQWDOOHQJWKUHTXLUHPHQWLQFOXGLQJD´ PP RYHUODSLHIURPWKHHOERZWRWKHRXWVLGHZDOO IDFHSOXV´ PP RUWKHGLVWDQFHUHTXLUHGLILQVWDOOLQJ DVHFRQGHOERZ )LJXUH NOTE: Always install vertical side wall horizontal venting ZLWKD´ULVHIRUHYHU\´RIUXQ 20 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 8VHDSSURSULDWHOHQJWKRISLSHVHFWLRQV±WHOHVFRSLFRU ¿[HG ± DQG LQVWDOO 7KH VHFWLRQV ZKLFK JR WKURXJK WKH ZDOODUHSDFNDJHGZLWKWKHVWDUWHUNLWDQGFDQEHFXWWR VXLWLIQHFHVVDU\ *XLGH WKH YHQW WHUPLQDWLRQV DQG FROODUV LQWR WKHLUUHVSHFWLYHYHQWSLSHV'RXEOHFKHFNWKDWWKHYHQW SLSHV RYHUODS WKH FROODUV E\ PP 6HFXUH WKH termination to the wall with screws provided and caulk DURXQGWKHZDOOSODWHWRZHDWKHUSURRI$VDQDOWHUQDWLYH WR VFUHZLQJ WKH WHUPLQDWLRQ GLUHFWO\ WR WKH ZDOO \RX PD\DOVRXVHH[SDQGLQJSOXJVRUDQDSSURYHGH[WHULRU FRQVWUXFWLRQDGKHVLYH X Vent Termination Below Grade ,QVWDOO6QRUNHO.LW6/36125.ZKHQLWLVQRWSRVVLEOHWR PHHWWKHUHTXLUHGYHQWWHUPLQDWLRQFOHDUDQFHVRI PP DERYHJUDGHOHYHO7KHVQRUNHONLWZLOODOORZLQVWDOODWLRQ GHSWKRIGRZQWR PP EHORZJUDGHOHYHO7KHVHYHQ LQFKHV LV PHDVXUHG IURP WKH FHQWHU RI WKH KRUL]RQWDO YHQW SLSH DV LW SHQHWUDWHV WKH ZDOO If the venting system is installed below grade, a window well must be installed with adequate and proper drainage. )LJXUH NOTE: Be sure to maintain side wall clearances and vent UXQUHVWULFWLRQV)LJXUHV (VWDEOLVKWKHYHQWKROHWKURXJKWKHZDOO 5HPRYHVRLOWRDGHSWKRIDSSUR[LPDWHO\ PP EHORZWKHEDVHRIWKHVQRUNHO,QVWDOODZLQGRZZHOO QRW VXSSOLHG 5H¿OO WKH KROH ZLWK PP RI FRDUVH JUDYHODQGPDLQWDLQDFOHDUDQFHRIDWOHDVW PP EHORZWKHVQRUNHO )LJXUH ,QVWDOOWKHYHQWV\VWHPDVGHVFULEHGRQ3DJHV %HVXUHWRPDNHDZDWHUWLJKWMRLQWDURXQGWKHYHQWSLSH MRLQWDWWKHLQVLGHDQGRXWVLGHZDOOMRLQWV $SSO\ KLJK WHPSHUDWXUH VHDODQW DURXQG WKH LQQHU DQG RXWHU VQRUNHO FROODUV -RLQ WKH SLSHV DQG IDVWHQ WKH VQRUNHOWHUPLQDWLRQWRWKHZDOOZLWKWKHVFUHZVSURYLGHG /HYHO WKH VRLO WR PDLQWDLQ D FOHDUDQFH EHORZ WKH VQRUNHO )LJXUH+RUL]RQWDO/HQJWK5HTXLUHPHQW NOTE: Support horizontal pipes every 5' (152 cm) with metal pipe straps. ,I WKH IRXQGDWLRQ LV UHFHVVHG XVH H[WHQVLRQ EUDFNHWV QRWVXSSOLHG WRIDVWHQWKHORZHUSRUWLRQRIWKHVQRUNHO )DVWHQWKHEUDFNHWVWRWKHZDOO¿UVWDQGWKHQIDVWHQWRWKH VQRUNHOZLWKVHOIWDSSLQJ[VKHHWPHWDOVFUHZV ([WHQGWKHYHQWSLSHVRXWDVIDUDVWKHSURWUXGLQJZDOO IDFH )LJXUH Recessed Wall &XWRXW2Q9LQ\O )LUHVWRS Sheet Metal Screws and Bracket )LQLVKLQJ Collar Wall Screws DQG$QFKRUV Waterproof Seal $URXQG3LSH 3LSH 9LQ\O6LGLQJ:DOO Wall Plate )LJXUH8VHH[WHQVLRQEUDFNHWVWRPRXQWVQRUNHODJDLQVW recessed wall. Termination Cap )LJXUH+RUL]RQWDO7HUPLQDWLRQ&DSRQD9LQ\O6LGLQJ:DOO 21 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Wall Screws DQG$QFKRUV Waterproof Seal $URXQG3LSH )LUHVWRS Snorkel Termination Cap 6/3+96 VXSSRUWV RIIVHWV7KLV DSSOLFDWLRQ ZLOO UHTXLUH WKDW \RX ¿UVW GHWHUPLQH WKH URRI SLWFK DQG XVH WKH DSSURSULDWH VWDUWHU NLW 5HIHU WR 9HQWLQJ &RPSRQHQWV OLVW 7KHPD[LPXPDQJXODUYDULDWLRQDOORZHGLQWKHV\VWHPLV )LJXUH )RU WKH PLQLPXP KHLJKW RI WKH YHQW DERYH WKH KLJKHVW SRLQWRISHQHWUDWLRQWKURXJKWKHURRIUHIHUWR)LJXUH &OHDUDQFH *UDYHO Drain Window Well RADIANCE )LJXUH6QRUNHONLWLQVWDOODWLRQ Vertical Through-The-Roof Application/installation Note:5HIHUWR¿JXUHVWKUXIRUUHVWULFWRUSODWHDGMXVWPHQWV IRUYHUWLFDOYHQWUXQV 7KLVJDVVWRYHKDVEHHQDSSURYHGIRU 9HUWLFDOLQVWDOODWLRQVXSWR P LQKHLJKW8SWRD P KRUL]RQWDOYHQWUXQFDQEHLQVWDOOHGZLWKLQWKH YHQWV\VWHPXVLQJDPD[LPXPRIWZRHOERZVFigure 38 8SWRWZRHOERZVPD\EHXVHGZLWKLQWKHKRUL]RQWDO UXQ )RU HDFK HOERZ XVHG RQ WKH KRUL]RQWDO SODQH WKHPD[LPXPKRUL]RQWDOOHQJWKPXVWEHUHGXFHGE\ PP Example:0D[LPXPKRUL]RQWDOOHQJWK 1RHOERZV P [HOERZ P [HOERZV P $ PLQLPXP RI DQ P YHUWLFDO ULVH LV UHTXLUHG )LJXUH • 22 Two sets of 45° elbow offsets may be used within the YHUWLFDOVHFWLRQV)URPWRDPD[LPXPRI P RI YHQWSLSHFDQEHXVHGEHWZHHQHOERZV)LJXUH Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Vertical Termination Horizontal overhang 20 in. (508 mm) 24 in. min. (610 mm) Vertical wall Lowest Discharge Opening Storm Collar Termination Cap )ODVKLQJ X Storm Collar 12 Roof Flashing Roof Pitch is X / 12 H (min.) - Minimum height from roof to lowest discharge opening. 2IIVHW Support Collar Roof Pitch )LUHVWRS Spacer H (Min.) Ft. Roof Pitch H (Min.) Ft. )ODWWR 2YHUWR 2YHUWR 2YHUWR 2YHUWR 2YHUWR 2YHUWR 2YHUWR 2YHUWR 2YHUWR 2YHUWR 2YHUWR )W0LQLPXPLQ6QRZ5HJLRQV )LJXUH0LQLPXP+HLJKWIURP5RRIWR/RZHVW'LVFKDUJH Opening Venting System Assembly - Natural Vent The heater is shipped from the factory as a Direct Vent +HDWHU ,W PD\ EH FRQYHUWHG WR D 1DWXUDO 9HQW KHDWHU E\ LQVWDOOLQJWKH0RGHO)6'+$*6/3'UDIW+RRG$GDSWHU &HLOLQJ Support Plate &HLOLQJ6XSSRUW&ROODU 7KH KHDWHU LV DSSURYHG IRU LQVWDOODWLRQ DV D 1DWXUDO 9HQW +HDUWKDQG+RPH7HFKQRORJLHV'LUHFW9HQWSLSHFRXOGEH XVHGGLUHFWO\DIWHUWKH'UDIW+RRG$GDSWHUXSWRWKHFHLOLQJ WKHQ%YHQWSLSHPXVWEHXVHG'RQRWPL[W\SHVRI%YHQW SLSHXVHFRPSRQHQWVIURPRQHPDNHURUWKHRWKHU)ROORZ WKH YHQW FRPSRQHQW PDNHU¶V LQVWUXFWLRQV H[DFWO\ 7KH KHDWHUZLOODOVRDFFHSWVWDQGDUGRUHQDPHOHG´ PP GLDPHWHU SLSH DURXQG WKH 7\SH % YHQWLQJ IRU GHFRUDWLYH SXUSRVHVRQO\ )LJXUH NOTE: The restrictor plate supplied with the stove is not used for Natural Vent applications. Trim Plate )LJXUH7\SLFDO9HUWLFDO9HQWLQJ&RQ¿JXUDWLRQ 23 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Decorative ´3LSH ´%YHQW Pipe ++7'LUHFW9HQW System may be used IURP'UDIW+RRGXS WRWKHFHLOLQJ 'UDIW+RRG $GDSWHU ENT CEM )LJXUH 'HFRUDWLYH ´ SLSH PD\ EH ¿WWHG DURXQG WKH %YHQW SLSH 7KHVWRYHZKHQLQVWDOOHGDVD1DWXUDOYHQWKHDWHULQFOXGHV D YHQW VDIHW\ VZLWFK 2SHUDWLQJ WKH VWRYH ZKHQ LW LV QRW FRQQHFWHG WR D SURSHUO\ LQVWDOOHG DQG PDLQWDLQHG YHQWLQJ V\VWHPRUWDPSHULQJZLWKRUGLVFRQQHFWLQJWKHYHQWVDIHW\ VZLWFKFDQUHVXOWLQFDUERQPRQR[LGH &2 SRLVRQLQJDQG SRVVLEOHGHDWK For U.S. installations:7KHYHQWLQJV\VWHPPXVWFRQIRUP ZLWKORFDOFRGHVDQGRUWKHFXUUHQW1DWLRQDO)XHO*DV&RGH $16,= )LJXUH,QVWDOOGUDIWKRRGDGDSWHU Install Log Set: %HIRUH EHJLQQLQJ ORJ LQVWDOODWLRQ UHPRYH VWRYH IURQW DQG JODVVIUDPH5HIHUWR)LJXUHVDQG Note: Remove the safety barrier before you remove the glass frame. To remove the barrier, simply lift up and pull out until the tabs are clear of their corresponding slots RQWKH¿UHER[7KHQSURFHHGWRUHPRYHWKHJODVVIUDPH by following the steps below. For Canadian installations: 7KH YHQWLQJ V\VWHP PXVW FRQIRUPWRWKHFXUUHQW&6$%LQVWDOODWLRQFRGH $SSO\DEHDGRIVHDODQWDURXQGERWWRPHQGRILQQHUVWDUWHU SLSH IRXQGLQEDJZLWKORJVHW DQGDWWDFKWRVWRYH$SSO\D bead of sealant around top of inner starter pipe and install WKH )6'+$*6/3 'UDIW +RRG DFFRUGLQJ WR 'UDIW +RRG LQVWUXFWLRQV )LJXUH $WWDFK WKH ¿UVW VHFWLRQ RI YHQWLQJ WR WKH GUDIW KRRG 'HSHQGLQJRQWKHOHQJWKRIWKHLQGLYLGXDOYHQWLQJVHFWLRQV DQGWKHOHQJWKVRIWKHGHFRUDWLYHSLSH LILQVWDOOHG \RXPD\ QHHG WR VOLS WKH GHFRUDWLYH SLSH RYHU WKH YHQWLQJ VHFWLRQV EHIRUHDWWDFKLQJXSSHUVHFWLRQVWRORZHURQHV7KHVHFWLRQV of decorative pipe should be oriented with their seams (if any) toward the wall; sections usually do not need to be IDVWHQHGDWHDFKMRLQWRWKHUWKDQVOLSVHFWLRQV,IWKHOD\RXW includes a slip section, this should be the last section of SLSHYLVLEOHLQWKHURRPDWWKHFHLOLQJ&RPSOHWHWKHYHQWLQJ DFFRUGLQJWRWKHYHQWPDNHU¶VLQVWUXFWLRQV )LJXUH5HPRYHWKHVDIHW\EDUULHUDQGVWRYHIURQW )LJXUH5HOHDVHWKHODWFKHVWRUHPRYHWKHJODVVIUDPH 24 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed. ,QVWDOOWKHOHIWORJE\PDWLQJWKHKROHRQWKHERWWRPRIWKH ORJ ZLWK WKH SLQ LQ WKH HPEHU EHG )LJXUH 3RVLWLRQ WKHORJRYHUDLUKROHLQHPEHUEHG ,QVWDOOWKHULJKWORJE\PDWLQJWKHQRWFKRQWKHERWWRPRI WKHORJZLWKWKHUDLVHGQRWFKRQWKHHPEHUEHG )LJXUH 3RVLWLRQWKHORJRYHUDLUKROHLQHPEHUEHG ,QVWDOO WRS ORJ E\ PDWLQJ KROH RQ ERWWRP RI ORJ ZLWK ORFDWLQJ SLQ RQ WRS ULJKW VLGH RI UHDU ORJ )LJXUH 3RVLWLRQORJVRLWLVDQJOHGGRZQWRZDUGWKHDUHDZKHUH WKHIURQWWZRORJVPHHW /HIW/RJ 5LJKW/RJ Install Log Set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aised 1RWFK Pin (PEHU%HG )LJXUH - Completed Installation )LJXUH5HDU/RJ 5HDU/RJ Pilot $VVHPEO\ )LJXUH5LEVIRU/RJV 25 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Install ON/OFF Switch – SDDVT models 7KHVZLWFKDVVHPEO\SDUWVDUHIRXQGLQWKHSDUWVEDJ $WWDFKVZLWFKDVVHPEO\WROHIWUHDUVLGHRIVWRYHVKURXG ZKHQ IDFLQJ VKURXG XVLQJ WZR VFUHZV DQG H[LVWLQJ KROHVLQVKURXG )LJXUH Run wires down back of stove, under bottom of rear VKURXGWRYDOYH $WWDFKZLUHVWRYDOYHWHUPLQDOV )LJXUH Signature Command® System - General: 6'976&PRGHOVDUHHTXLSSHGZLWKWKH6LJQDWXUH&RPPDQG FRQWUROYDOYH )LJXUH ZKLFKRSHUDWHVRQYROWV7KH$& PRGXOHSOXJVLQWRWKHVWRYHMXQFWLRQER[$&SRZHUVXSSO\ )RXU ³$$´EDWWHULHVDUHXVHGIRUEDFNXSGXULQJSRZHU RXWDJHV 7KH 6LJQDWXUH &RPPDQG 6\VWHP FDQ DOVR EH RSHUDWHG ZLWKRXW$& SRZHU 7KH V\VWHP FDQ UXQ RQ IRXU ³$$´ EDWWHULHVIRUDSSUR[LPDWHO\VL[ PRQWKVXQGHUQRUPDOXVH $& SRZHU PXVW EH XVHG WR SRZHU WKH$& PRGXOH DQG EORZHUV Switch $VVHPEO\ ([LVWLQJ +ROHV Pressure Inlet Screws )LJXUH$WWDFKVZLWFKDVVHPEO\WRUHDUVKURXG SIT VALVE 3LORW$GMXVWPHQW Screw 3UHVVXUH2XWOHW Valve TPTH )LJXUH6LJQDWXUH&RPPDQG9DOYH Thermopile TP ! TH PI LO T ON/OFF Switch or Millivolt Thermostat )LJXUH,QVWDOOZLULQJWRVZLWFKEHIRUHFRQQHFWLQJWRYDOYH Thermostat or wall switch Connection (optional): 8VHRQO\DWKHUPRVWDWUDWHGIRUPLOOLYROWV &KHFNWKHWDEOHEHORZIRUWKHDSSURSULDWHJDXJHWKHUPRVWDW ZLUHWRXVHIRUWKHOHQJWKRIOHDGUHTXLUHGLQ\RXULQVWDOODWLRQ Thermostat Wire / Gauge Maximum Run 18 )HHW 16 )HHW 14 XSWR)HHW WARNING (OHFWULFDO FRQQHFWLRQV VKRXOG RQO\ EH SHUIRUPHG E\ D TXDOL¿HG OLFHQVHG HOHFWULFLDQ 0DLQ SRZHU PXVW EH RII ZKHQ FRQQHFWLQJ WR PDLQ HOHFWULFDO SRZHU VXSSO\ RU SHUIRUPLQJ VHUYLFH $OO ZLULQJ VKDOO EH LQ FRPSOLDQFH ZLWKDOOORFDOFLW\DQGVWDWHFRGHV7KHDSSOLDQFHZKHQ LQVWDOOHG PXVW EH HOHFWULFDOO\ JURXQGHG LQ DFFRUGDQFH with local codes or in the absence of local codes, with the 1DWLRQDO(OHFWULFDO&RGH$16,1)3$ ODWHVWHGLWLRQ DQG &DQDGLDQ(OHFWULFDO&RGH&6$& ! CAUTION /DEHO DOO ZLUHV EHIRUH GLVFRQQHFWLQJ ZKHQ VHUYLFLQJ FRQWUROV:LULQJHUURUVFDQFDXVHLPSURSHUDQGGDQJHURXV RSHUDWLRQ ,QVWDOOWKHZDOOWKHUPRVWDWRUVZLWFKLQWKHGHVLUHGORFDWLRQ DQGUXQWKHZLUHVWRWKHVWRYHORFDWLRQ7HUPLQDWHWKHVH OHDGVZLWKIHPDOHFRQQHFWRUV &RQQHFWWKHWKHUPRVWDWZLUHVWRWKHYDOYH )LJXUH 26 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Junction Box Wiring 7KLV VKRXOG EH GRQH EHIRUH IUDPLQJ WKH VWRYH :LUH WKH UHFHSWDFOHLQWRDQHOHFWULFDOFLUFXLW:LUHZLWKPLQLPXP &ZLUHLQDFFRUGDQFHZLWKSUHYDLOLQJFRGHV ! (OHFWULFDO FRQQHFWLRQV VKRXOG RQO\ EH SHUIRUPHG E\ D TXDOL¿HG OLFHQVHG HOHFWULFLDQ 0DLQ SRZHU VXSSO\ PXVW EHWXUQHGRIIEHIRUHFRQQHFWLQJIDQVWRWKHPDLQHOHFWULFDO SRZHUVXSSO\RUSHUIRUPLQJVHUYLFH 5HPRYH WKH H[WHUQDO MXQFWLRQ ER[ FRYHU E\ UHPRYLQJ WKH VFUHZIURPWKHVLGHRIWKHRXWVLGH¿UHER[ZDOO-XQFWLRQER[ ZDVLQVWDOOHGDWWKHIDFWRU\ 7KHMXQFWLRQER[FRYHUKDVDIDFWRU\LQVWDOOHG³URPH[´VW\OH VWUDLQUHOLHIFRQQHFWRU$IWHUFRQQHFWLQJWKHZLUHVURXWHWKH ZLUHOHDGVWKURXJKWKLVFRQQHFWRU5HIHUWRWKHZLULQJGLDJUDP LQ)LJXUH 9$& +] )DFWRU\6XSSOLHG 1RW6XSSOLHG ! Command Center Wall Installation The command center may be mounted on the wall with the XVHRIWKH6&6:(..LW IWFDEOHMXQFWLRQER[ZDOOFRYHU WARNING (OHFWULFDO *URXQGLQJ ,QVWUXFWLRQV 7KLV DSSOLDQFH LV HTXLSSHG ZLWK D WKUHHSURQJ JURXQGLQJ SOXJ IRU \RXU SURWHFWLRQDJDLQVWVKRFNKD]DUGDQGVKRXOGEHSOXJJHG GLUHFWO\LQWRDSURSHUO\JURXQGHGWKUHHSURQJUHFHSWDFOH Install the Fan – SDVTSC Models ,WLVHDVLHVWWRLQVWDOOWKHIDQNLWEHIRUHFRQQHFWLQJDJDVOLQH • 8QSDFNDQGLQVSHFWWKHEORZHUDVVHPEO\&RQ¿UPWKDW WKHIDQVSLQVIUHHO\ • 8QIDVWHQ WKH WZR PDFKLQH EROWV DWWDFKHG WR WKH ORZHU EDFNRIWKHVWRYH )LJXUH • 8VLQJWKHWZREROWVVHFXUHWKHEORZHUDVVHPEO\WRWKH UHDURIWKHVWRYH )LJXUH •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all Switch Installation 7KHZDOOVZLWFKZLUHFRQQHFWLRQLVORFDWHGRIIWKHIWZLUH KDUQHVVIURPWKHFRQWUROER[WRWKHFRPPDQGFHQWHU)LJXUH 7KHFRQQHFWLRQLVODEHOHG³:DOO6ZLWFK´8QSOXJWKHPDOH DQGIHPDOHFRQQHFWRUVDQGFRQQHFWWKHWZR ORZYROWDJH ZLUHVSURYLGHG5XQZLUHWRGHVLUHGORFDWLRQRQZDOO8SWR IWRIJDZLUHPD\EHXVHGLIQHFHVVDU\$WWDFKZLUHV WRZDOOVZLWFK0RXQWWKHZDOOVZLWFKLQWRMXQFWLRQER[DQG VFUHZRQFRYHU ! WARNING 'RQRWFRQQHFWZDOOVZLWFKWR9FLUFXLW Figure 51 - 6HFXUH%ORZHUDVVHPEO\WRORZHUEDFNRIWKHVWRYH 27 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Connect the Gas Supply Line &KHFN WKH 5DWLQJ 3ODWH DWWDFKHG E\ D VWHHO FDEOH WR WKH ¿UHER[ WR FRQ¿UP WKDW \RX KDYH WKH DSSURSULDWH ¿UHER[ IRU WKH W\SH RI IXHO WR EH XVHG 7KH 6WDUGDQFH PD\ EH FRQYHUWHGIURPRQHJDVWRDQRWKHUXVLQJWKHDSSURSULDWH)XHO &RQYHUVLRQ.LWOLVWHGLQWKLVPDQXDOXQGHU5HSODFHPHQW3DUWV In the U.S.;*DVFRQQHFWLRQVKRXOGEHPDGHLQDFFRUGDQFH ZLWKFXUUHQW1DWLRQDO)XHO*DV&RGH$16,=1)3$ Since some municipalities have additional local codes, be VXUHWRFRQVXOW\RXUORFDODXWKRULW\ In Canada; FRQVXOW WKH ORFDO DXWKRULW\ DQG &6$% LQVWDOODWLRQFRGH NOTE: Always check for gas leaks with a mild soap and ZDWHUVROXWLRQ'RQRWXVHDQRSHQÀDPHIRUOHDNWHVWLQJ /LJKWWKHSLORWDFFRUGLQJWRWKHGLUHFWLRQVLQWKH2SHUDWLRQ VHFWLRQRIWKLVPDQXDO Burner Information 7KHDSSOLDQFHPXVWRQO\XVHWKHJDVVSHFL¿HGRQWKHUDWLQJ SODWH XQOHVV FRQYHUWHG XVLQJ D 9HUPRQW &DVWLQJV )XHO &RQYHUVLRQ.LW7RFRQYHUWIURP1DWXUDO*DVWR/3XVH.LW RU7RFRQYHUWIURP/3WR1DWXUDO*DV XVH.LWRU Conversion instructions are provided with each kit and in WKLVPDQXDO ! CAUTION 7KLVDSSOLDQFHVKRXOGRQO\EHFRQQHFWHGE\DTXDOL¿HG JDV WHFKQLFLDQ 7HVW WR FRQ¿UP PDQLIROG SUHVVXUHV DV VSHFL¿HGEHORZ 7KH6WDUGDQFH+HDWHUDQGLWVLQGLYLGXDOVKXWRIIYDOYHPXVW EHGLVFRQQHFWHGIURPWKHJDVVXSSO\SLSLQJGXULQJDQ\ SUHVVXUHWHVWLQJRIWKDWV\VWHPDWWHVWSUHVVXUHVLQH[FHVV RISVLJ N3D 7KH 6WDUGDQFH +HDWHU PXVW EH LVRODWHG IURP WKH JDV VXSSO\ SLSLQJ V\VWHP E\ FORVLQJ LWV LQGLYLGXDO PDQXDO VKXWRIIYDOYHGXULQJDQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\ SLSLQJV\VWHPDWWHVWSUHVVXUHHTXDOWRRUOHVVWKDQ SVLJ 7KHUHPXVWEHDJDVVKXWRIIEHWZHHQWKHVWRYHDQGWKH VXSSO\ ,QRUGHUWRFRQQHFW1DWXUDO*DVXVHD¿WWLQJZLWK137 RQ WKH YDOYH VLGH DQG QDWXUDO JDV VXSSO\ OLQH ZLWK DQLQSXWRI%78VDWDPDQLIROGSUHVVXUHRI EHWZHHQPLQLPXPLQOHWVXSSO\RIZFDQGPD[LPXP RIZF ,QRUGHUWRFRQQHFW3URSDQHXVHD¿WWLQJZLWK137 RQWKHYDOYHVLGHDQGSURSDQHJDVVXSSO\OLQHZLWK DQLQSXWRI%78VDWDPDQLIROGSUHVVXUHRI EHWZHHQDPLQLPXPLQOHWVXSSO\RIZFDQGPD[LPXPRIZF THIS APPLIANCE SHOULD BE CONNECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN. FOLLOW ALL LOCAL CODES. THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY. 28 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Signature Command Wiring Diagram Pilot A/C MODULE Opt. Blower Opt. Aux. WHITE BLACK BLACK WHITE PLUG-IN CONNECTOR TO JUNCTION BOX IN FIREPLACE RF Receiver ON/OFF Button GREEN 300 Watt Max. Control Board Black / Thermopile Red / Thermopile Sensor Conversion NG/LP Ignitor / Sparker Plug-in Connector Control Board to Command Center NOTE: Wall switch wires must be connected together if a wall switch is not being used. OFF/LO Ground Plug-in Connector Stepper Motor to Control Board LED ON/HI Master Switch Command Center Optional Wall Switch DC Power/Green Plug-in Connector Control Board to Solenoid Gas Out Gas In Pilot Gas Tubing Valve Figure 526LJQDWXUH&RPPDQG:LULQJ'LDJUDP To Junction Box In Fireplace Light { WHITE BLACK Optional AUX { WHITE BLACK BLACK WHITE GREEN Connector Pin To Control Box )LJXUH%ORZHU:LULQJ'LDJUDP 29 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Install the Safety Barrier CERTIFIED SAFETY BARRIER NOTE: A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer's barrier for this appliance.* Any safety screen, guard, or barrier removed for servicing the appliance must be replaced prior to operating the appliance. %RWWRP+RRNV )LJXUH,QVWDOOVDIHW\EDUULHUVFUHHQ * See parts list for model number. 7KHVDIHW\EDUULHUKDVEHHQGHVLJQHGWRZRUNZLWKWKH GRRUVRSHQRUFORVHG 5HPRYHVFUHHQIURPSDFNDJLQJ 3ODFHWKHWZRERWWRPKRRNVRYHUWKHERWWRPHGJHRIWKH VWRYHRSHQLQJ)LJXUH 3UHVV WKH VFUHHQ DJDLQVW WKH VWRYH VQDSSLQJ WKH WZR VSULQJ¿QJHUVXQWLOWKHVFUHHQ¿WVVHFXUHO\LQSODFH NOTE: It is the responsibility of the installer to ensure the EDUULHULVDI¿[HGWRWKHVWRYHDWWKHWLPHRILQVWDOODWLRQ ! WARNING 7KHVDIHW\VFUHHQEDUULHUPXVWEHLQVWDOOHGDIWHUWKHJODVV IURQWLVLQSODFH,WLVQRWDUHSODFHPHQWIRUWKHJODVVDQG WKHXQLWPXVWQRWEHRSHUDWHGZLWKRXWWKHJODVVLQSODFH Install the Mesh and Grille 3ODFHWKHPHVKDQGJULOOHRQWKHWRSRIWKH5DGLDQFHVWRYH WRFRPSOHWHDVVHPEO\ DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed. 30 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Operating instructions Operation The Stardance is operated with the front plate in place with WKHGRRUVRSHQRUFORVHGDQGWKHVDIHW\EDUULHULQSODFH7R RSHQWKHIURQWGRRUVSXOOIRUZDUGWRVHSDUDWHWKHPDJQHWLF FDWFK Flame Characteristics It is important to periodically perform a visual check of the SLORWDQGWKHEXUQHUÀDPHV&RPSDUHWKHPWR)LJXUH,I DQ\RIWKHÀDPHVDSSHDUDEQRUPDOFDOODVHUYLFHSHUVRQ Your First Fire 5HDGWKHVHLQVWUXFWLRQVFDUHIXOO\DQGIDPLOLDUL]H\RXUVHOIZLWK WKHEXUQHUFRQWUROVVKRZQRQ3DJH 6''97PRGHOV RU SDJH 6'976&PRGHOV /RFDWHWKHSLORWDVVHPEO\)LJXUH )ROORZWKHOLJKWLQJLQVWUXFWLRQVLQWKLVPDQXDOH[DFWO\ 'XULQJ WKH ¿UVW ¿UH LW LV QRW XQXVXDO WR VPHOO VRPH RGRU DVVRFLDWHG ZLWK QHZ ORJV SDLQW DQG PHWDO EHLQJ KHDWHG 2GRUV VKRXOG GLVVLSDWH ZLWKLQ WKH ¿UVW HLJKW WR WHQ KRXUV however, you can open a window to provide fresh air to DOOHYLDWHWKHFRQGLWLRQ Pilot and Burner Inspection (DFKWLPH\RXOLJKW\RXUKHDWHUFKHFNWKDWWKHSLORWÀDPHDQG EXUQHUÀDPHSDWWHUQVDUHDVVKRZQLQ)LJXUH,IÀDPH SDWWHUQVDUHLQFRUUHFWWXUQWKHKHDWHURII&RQWDFW\RXUGHDOHU RUDTXDOL¿HGJDVWHFKQLFLDQIRUDVVLVWDQFH'RQRWRSHUDWH WKHKHDWHUXQWLOWKHSLORWÀDPHLVFRUUHFW SDDVT MODELS )ROORZUHJXODUPDLQWHQDQFHSURFHGXUHVDVGHVFULEHGLQWKH &OHDQLQJDQG0DLQWHQDQFHVHFWLRQRIWKLVPDQXDO Sensor SDVTSC MODELS Thermopile 3LORW$VVHPEO\ Figure 553LORW$VVHPEO\ORFDWLRQ Figure 56&RUUHFWSLORWDQGEXUQHUÀDPHDSSHDUDQFH Turn counterclockwise to increase flame height HI Flame & Temperature Adjustment )RU6''97PRGHOVZKLFKDUHHTXLSSHGZLWK+,/2YDOYHV ÀDPH DGMXVWPHQW LV DFFRPSOLVKHG E\ URWDWLQJ WKH +,/2 DGMXVWPHQWNQREORFDWHGQHDUWKHFHQWHURIWKHJDVFRQWURO YDOYH )LJXUH LO Turn clockwise to decrease flame height )LJXUH)ODPHDGMXVWPHQWNQREIRU6,7YDOYH 31 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 LIGHTING AND OPERATING INSTRUCTIONS FOR RADVT MODELS (MILLIVOLT ONLY) FOR YOUR SAFETY READ BEFORE LIGHTING :$51,1*,I\RXGRQRWIROORZWKHVHLQVWUXFWLRQVH[DFWO\D¿UHRUH[SORVLRQ may result causing property damage, personal injury or loss of life. $ 7KLVKHDWHUKDVDSLORWZKLFKPXVWEHOLWPDQXDOO\:KHQ OLJKWLQJWKHSLORWIROORZWKHVHLQVWUXFWLRQVH[DFWO\ % %()25(/,*+7,1*VPHOODOODURXQGWKHKHDWHUDUHD IRUJDV%HVXUHWRVPHOOQH[WWRWKHÀRRUEHFDXVHVRPH JDVLVKHDYLHUWKDQDLUDQGZLOOVHWWOHRQWKHÀRRU WHAT TO DO IF YOU SMELL GAS 'RQRWWU\WROLJKWDQ\VWRYH • Do not touch any electric switch 'RQRWXVHDQ\SKRQHLQ\RXUEXLOGLQJ ,PPHGLDWHO\FDOO\RXUJDVVXSSOLHUIURPDQHLJKERU¶V SKRQH)ROORZWKHJDVVXSSOLHU¶VLQVWUXFWLRQV ,I\RXFDQQRWUHDFK\RXUJDVVXSSOLHUFDOOWKH)LUH Department &8VHRQO\\RXUKDQGWRSXVKLQRUWXUQWKHJDVFRQWURO NQRE1HYHUXVHWRROV,IWKHNQREZLOOQRWSXVKLQRUWXUQ E\KDQGGRQRWWU\WRUHSDLULWFDOODTXDOL¿HGVHUYLFH WHFKQLFLDQ$SSO\LQJIRUFHRUDQ\DWWHPSWHGUHSDLUPD\ UHVXOWLQD¿UHRUH[SORVLRQ ''RQRWXVHWKLVVWRYHLIDQ\SDUWKDVEHHQXQGHUZDWHU ,PPHGLDWHO\FDOODTXDOL¿HGVHUYLFHWHFKQLFLDQWRLQVSHFW the heater and to replace any part of the control system DQGDQ\JDVFRQWUROZKLFKKDVEHHQXQGHUZDWHU Lighting Instructions STOP!5HDGWKHVDIHW\LQIRUPDWLRQDERYH 7XUQRIIDOOHOHFWULFDOSRZHUWRWKHVWRYH 7XUQWKH2Q2IIVZLWFKWR³2))SRVLWLRQVHWWKHUHPRWH WR2))RUVHWWKHUPRVWDWWRORZHVWOHYHO 2SHQFRQWURODFFHVVSDQHO 3XVKWKHFRQWURONQREDOOWKHZD\LQDQGKROG,PPHGLDWHO\ OLJKWWKHSLORWE\UHSHDWHGO\GHSUHVVLQJWKHSLH]RVSDUN LJQLWRU XQWLO D ÀDPH DSSHDUV &RQWLQXH WR KROG WKH control knob in for about one (1) minute after the pilot LVOLW5HOHDVHNQREDQGLWZLOOSRSEDFNXS3LORWVKRXOG UHPDLQOLW,ILWJRHVRXWUHSHDWVWHSVWKURXJK 3XVK LQ JDV FRQWURO NQRE VOLJKWO\ DQG WXUQ FORFNZLVH WR³2)) ON OFF PILOT OFF • SIT NOVA :DLW¿YH PLQXWHVWRFOHDURXWDQ\JDV7KHQVPHOO IRUJDVLQFOXGLQJQHDUWKHÀRRU,I\RXVPHOOJDV6723 )ROORZ³%LQWKHVDIHW\LQIRUPDWLRQDERYH,I\RXGRQRW VPHOOJDVJRWRWKHQH[WVWHS If knob does not pop up when released, stop and LPPHGLDWHO\FDOO\RXUVHUYLFHWHFKQLFLDQRUJDVVXSSOLHU ,IDIWHUVHYHUDOWULHVWKHSLORWZLOOQRWVWD\OLWWXUQWKHJDV FRQWURONQREWR³2))DQGFDOO\RXUVHUYLFHWHFKQLFLDQ RUJDVVXSSOLHU 5HPRYH JODVV GRRU EHIRUH OLJKWLQJ SLORW 6HH *ODVV )UDPH5HPRYDOVHFWLRQ 5HSODFHJODVVGRRU 9LVLEO\ORFDWHSLORWE\WKHPDLQEXUQHU 7XUQ WKH 2Q2II VZLWFK WR ³21 SRVLWLRQ RU VHW WKHUPRVWDWWRGHVLUHGVHWWLQJ 7XUQ NQRE RQ JDV FRQWURO FRXQWHUFORFNZLVH ³3,/27 to 7XUQJDVFRQWURONQREWR³21SRVLWLRQ 7XUQRQDOOHOHFWULFDOSRZHUWRWKHVWRYH To Turn Off Gas To Heater 7XUQWKH2Q2IIVZLWFKWR2IISRVLWLRQRUVHWWKHWKHUPRVWDW WRORZHVWVHWWLQJ 7XUQRIIDOOHOHFWULFSRZHUWRWKHVWRYHLIVHUYLFHLVWREH SHUIRUPHG 32 2SHQFRQWURODFFHVVSDQHO 3XVK LQ JDV FRQWURO NQRE VOLJKWO\ DQG WXUQ FORFNZLVH WR³2))'RQRWIRUFH &ORVHFRQWURODFFHVVSDQHO Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 TROUBLESHOOTING THE GAS CONTROL SYSTEM (SDDVT SERIES) 6,7129$0,//,92/79$/9( 127(%HIRUHWURXEOHVKRRWLQJWKHJDVFRQWUROV\VWHPEHVXUHH[WHUQDOJDVVKXWRIILVLQWKH³2QSRVLWLRQ Symptom Possible Causes 6SDUN,JQLWRUZLOOQRW 'HIHFWLYHRUPLVDOLJQHG OLJKW electrode at pilot Pilot will not stay lit after carefully IROORZLQJOLJKWLQJ instructions 3LORWEXUQLQJQR JDVWRPDLQEXUQHU )UHTXHQWSLORW RXWDJHSUREOHP 8VLQJDPDWFKOLJKWSLORW,ISLORWOLJKWVWXUQRIISLORWDQGSXVKWKHUHGEXWWRQ DJDLQ,ISLORWZLOOQRWOLJKFKHFNJDSDWHOHFWURGHDQGSLORWVKRXOGEH´WR KDYHDVWURQJVSDUN 'HIHFWLYHLJQLWRU SXVK button) :LWKWKHFRQWURONQRELQWKHSLORWSRVLWLRQSXVKWKHFRQWURONQREDOOWKHZD\DQG KROG&KHFNIRUVSDUNDWHOHFWURGHDQGSLORW,IQRVSDUNWRSLORWDQGHOHFWURGH ZLUHLVSURSHUO\FRQQHFWHGUHSODFHWKHEDWWHU\LQWKHLJQLWRUPRGXOHDQGWU\ DJDLQ5HIHUWR0DLQWHQDQFH6HFWLRQ,IWKHSUREOHPVWLOOH[LVWVUHSODFHWKH LJQLWRUPRGXOHER[ 'HIHFWLYHSLORWJHQHUDWRU (thermocouple), remote wall switch &KHFN SLORW ÀDPH 0XVW LPSLQJH RQ WKHUPRFRXSOHWKHUPRSLOH 127( 7KLV SLORW EXUQHU DVVHPEO\ XWLOL]HV ERWK D WKHUPRFRXSOH DQG D WKHUPRSLOH 7KH WKHUPRFRXSOHRSHUDWHVWKHPDLQYDOYHRSHUDWLRQ 2QDQG2II &OHDQDQGRU DGMXVWSLORWIRUPD[LPXPÀDPHLPSLQJHPHQWRQWKHUPRSLOHDQGWKHUPRFRXSOH 'HIHFWLYHDXWRPDWLFYDOYH 7XUQYDOYHNQREWR³3LORW´0DLQWDLQÀRZWRSLORWPLOOLYROWPHWHUVKRXOGUHDG JUHDWHUWKDQP9,IWKHUHDGLQJLVRND\DQGWKHSLORWGRHVQRWVWD\RQUHSODFH WKH JDV YDOYH 127($Q LQWHUUXSWHU EORFN QRW VXSSOLHG PXVW EH XVHG WR FRQGXFWWKLVWHVW :DOOVZLWFKRUZLUHV defective &KHFN ZDOO VZLWFK DQG ZLUHV IRU SURSHU FRQQHFWLRQV -XPSHU ZLUH DFURVV WHUPLQDOVDWZDOOVZLWFKLIEXUQHUFRPHVRQUHSODFHGHIHFWLYHZDOOVZLWFK,I RND\MXPSHUZLUHVDFURVVZDOOVZLWFKZLUHVDWYDOYHLIEXUQHUFRPHVRQZLUHV DUHIDXOW\RUFRQQHFWLRQVDUHEDG 7KHUPRSLOHPD\QRWEH JHQHUDWLQJVXI¿FLHQW PLOOLYROWDJH • %HVXUHZLUHFRQQHFWLRQVIRUPWKHUPRSLOHDWJDVYDOYHWHUPLQDOVDUHWLJKW DQGWKHUPRSLOHLVIXOO\LQVHUWHGLQWRSLORWEUDFNHW • 2QHRIWKHZDOOVZLWFKZLUHVPD\EHJURXQGHG5HPRYHZDOOVZLWFKZLUHV IRUPYDOYHWHUPLQDOVLISLORWQRZVWD\VOLWWUDFHZDOOVZLWFKZLULQJIRUJURXQG 0D\EHJURXQGHGWRVWRYHRUJDVVXSSO\ • &KHFNWKHUPRSLOHZLWKPLOOLYROWPHWHU7DNHUHDGLQJDWWKHUPRSLOHWHUPLQDOV RIJDVYDOYH6KRXOGUHDGPLOOLYROWV PLQLPXP ZKLOHKROGLQJ YDOYHNQREGHSUHVVHGLQSLORWSRVLWLRQDQGZDOOVZLWFK³2II´5HSODFHIDXOW\ WKHUPRSLOHLIUHDGLQJLVEHORZVSHFL¿HGPLQLPXP 3OXJJHGEXUQHURUL¿FH &KHFNEXUQHURUL¿FHVIRUGHEULVDQGUHPRYH 'HIHFWLYHDXWRPDWLFYDOYH operator 7XUQYDOYHNQREWR³2Q´SODFHZDOOVZLWFKWR³2Q´PLOOLYROWPHWHUVKRXOGUHDG JUHDWHUWKDQP9,IWKHUHDGLQJLVRND\DQGWKHEXUQHUGRHVQRWFRPHRQ UHSODFHWKHJDVYDOYH 3LORWÀDPHPD\EHWRRORZ &OHDQDQGRUDGMXVWSLORWÀDPHIRUPD[LPXPÀDPHLPSLQJHPHQWRQWKHUPRSLOH RUEORZLQJ KLJK FDXVLQJ DQGWKHUPRFRXSOH the pilot safety to drop out 3RVVLEOHEORFNDJHRIWKH vent terminal 33 Corrective Action &KHFNWKHYHQWWHUPLQDOIRUEORFNDJH UHF\FOLQJWKHÀXHJDVHV Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 FOR YOUR SAFETY READ BEFORE LIGHTING ! WARNING ,I \RX GR QRW IROORZ WKHVH LQVWUXFWLRQ H[DFWO\ D ¿UH RU H[SORVLRQ PD\ UHVXOW FDXVLQJ SURSHUW\ GDPDJH personal injury or loss of life. A. 7KLVDSSOLDQFHLVHTXLSSHGZLWKDQLJQLWLRQGHYLFHZKLFKDXWRPDWLFDOO\OLJKWVWKHSLORW5HIHUWRWKHLQVWUXFWLRQV B. %()25(23(5$7,1*VPHOODOODURXQGWKHDSSOLDQFHDUHDIRUJDV%HVXUHWRVPHOOQH[WWRWKHÀRRUEHFDXVHVRPH JDVLVKHDYLHUWKDQDLUDQGZLOOVHWWOHRQWKHÀRRU WHAT TO DO IF YOU SMELL GAS: 'RQRWDWWHPSWWROLJKWDQ\DSSOLDQFH 'RQRWWRXFKDQ\HOHFWULFVZLWFKGRQRWXVHDQ\SKRQHLQ\RXUEXLOGLQJ ,PPHGLDWHO\FDOO\RXUJDVVXSSOLHUIURPDQHLJKERU VSKRQH)ROORZWKHJDVVXSSOLHU VLQVWUXFWLRQV ,I\RXFDQQRWUHDFK\RXUJDVVXSSOLHUFDOOWKH¿UHGHSDUWPHQW C. 8VHRQO\\RXU¿QJHUWRSXVKLQWKHPDVWHUVZLWFK1HYHUXVHWRROV,IWKHVZLWFKZLOOQRWIXQFWLRQE\KDQGGRQRWWU\ WRUHSDLULW&DOODTXDOL¿HGVHUYLFHWHFKQLFLDQ)RUFHRUDWWHPSWHGUHSDLUPD\UHVXOWLQD¿UHRUH[SORVLRQ D. 'RQRWXVHWKLVDSSOLDQFHLIDQ\SDUWRILWKDVEHHQXQGHUZDWHU,PPHGLDWHO\FDOODTXDOL¿HGVHUYLFHWHFKQLFLDQWR LQVSHFWWKHDSSOLDQFHDQGWRUHSODFHDQ\SDUWRIWKHFRQWUROV\VWHPDQGDQ\JDVFRQWUROWKDWKDVEHHQXQGHUZDWHU 34 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 LIGHTING AND OPERATING INSTRUCTIONS FOR RADVTSC MODELS 67235HDGWKHVDIHW\LQIRUPDWLRQDERYH 7KLVDSSOLDQFHLVHTXLSSHGZLWKDQLJQLWLRQGHYLFHZKLFKDXWRPDWLFDOO\OLJKWVWKHEXUQHU'RQRWWU\WROLJKWWKH EXUQHUE\KDQG :LWK¿YH PLQXWHVWRFOHDURXWDQ\JDV7KHQVPHOOIRUJDVLQFOXGLQJQHDUWKHÀRRU,I\RXVPHOOJDV6723 )ROORZ%LQWKHVDIHW\LQIRUPDWLRQRQ3DJH,I\RXGRQRWVPHOOJDVJRWRQH[WVWHS 3UHVVWKHPDVWHUVZLWFKWRWKH21 SRVLWLRQ:LWKLQHLJKW VHFRQGVLWZLOOEHHSRQFH7KLVLQGLFDWHVWKH V\VWHPLVUHDG\ 3UHVV21EXWWRQ6SDUNHUZLOOVSDUNDQGSLORWÀDPHZLOOOLJKW 2QFHSLORWÀDPHLVHVWDEOLVKHGWKHPDLQEXUQHUÀDPHZLOOOLJKWDXWRPDWLFDOO\ ,IWKHSLORWZLOOQRWVWD\OLWDIWHUVHYHUDOWULHVWXUQWKHPDVWHUVZLWFKWR2))DQGFDOO\RXUVHUYLFHWHFKQLFLDQRUJDV VXSSOLHU 2)) OFF ON Master Switch 21 Command Center TO TURN OFF GAS TO APPLIANCE 7XUQPDVWHUVZLWFKWR2)) 7XUQRIIDOOHOHFWULFDOSRZHUWRWKHDSSOLDQFHLIVHUYLFHLVWREHSHUIRUPHG 35 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Signature command operating instructions Features - Command Center (Figure 58) (DV\$FFHVV)XQFWLRQ2SHUDWLRQDQG6\VWHP&RQ¿JXUDWLRQ 2SHUDWLRQ&RQ¿UPDWLRQ)DXOW'LDJQRVWLF,QGLFDWLRQV /(' %X]]HU 212))+,0HG/RZ2SHUDWLRQ 2SWLRQDO:DOO0RXQWLQJ Control Board (OHFWURQLF,JQLWLRQ • Pilot Lockout safety feature (OHFWULF 3RZHU 5HJHQHUDWLRQ IURP 7KHUPRSLOH WR VDYH battery KRXU$XWRPDWLF6KXW'RZQ2SWLRQ &RQYHQLHQW1*/3*DV7\SH&RQYHUVLRQ 6WDQGLQJ3LORW,QWHUPLWWHQWSLORW&RQYHUVLRQ 3UHYLRXVVHWWLQJV5HVWRUDWLRQ$ELOLW\ 0HPRU\2II 8QLQWHUUXSWHG2SHUDWLRQ'XULQJ3RZHU2XWDJH $XWRPDWLF Battery Backup) 212))5)5HPRWH5HFHLYHU 2SWLRQDO7UDQVPLWWHU/HDUQ&DSDELOLW\ AC Module (Requires TSFSC Remote) (DV\6QDSRQ'HVLJQ (PEHGGHG &RPSDFW 9$&$GDSWHU ZLWK$XWR %DWWHU\ %DFNXS)HDWXUH 5HPRWH &RQWUROOHG VWHS %ORZHU /LJKWLQJ DQG 2Q2II $X[LOLDU\$&2XWSXWV Transmitter (TSFSC) 7KUHH)ODPH+HLJKW6HWWLQJV • Low battery Indication for Transmitter • Child Proof Lock-out /&'%DFNOLJKW • Security Codes (16) • Countdown 6 hr Timer • Standard Thermostatic Control Mode 6PDUW 0RGH 7KHUPRVWDW $XWR )ODPH Modulation) 7KUHH%ULJKWQHVV6HWWLQJVIRU/LJKWV • Three Speed Control for Blower 2Q2II$X[LOLDU\ 3URJUDPPDEOH7LPHUWRWXUQEORZHURQDQGRII 36 5)5HFHLYHU 212)) To Thermopile To Sensor To Sparker 1*/3 Conversion To Command Center Control Board 21 /(' To Stepper Motor To Valve Master Switch 2)) $&0RGXOH Battery Door Command Center Figure 58 - Signature Command System Components Battery Installation 7KH&RPPDQG&HQWHUXVHVIRXU $$EDWWHULHVDVEDFNXS IRUSRZHURXWDJHV7KHV\VWHPFDQRSHUDWHIRUDSSUR[LPDWHO\ VL[ PRQWKVRQEDWWHU\SRZHU 7R,QVWDOO%DWWHULHV QRWLQFOXGHG 3UHVVGRZQWKHEDWWHU\GRRUWDEVDQGSXOORXWWRUHPRYH EDWWHU\GRRU ,QVWDOOWKHEDWWHULHVDVLQGLFDWHGRQ&RPPDQG&HQWHU &ORVHEDWWHU\GRRUE\VQDSSLQJLQSODFH %ORZHU :KHQWKHIRXU EDWWHULHVDUHLQVWDOOHGWKHV\VWHPZLOO RSHUDWHZLWKRXWSRZHU 7KHEDWWHULHVVKRXOGEHUHSODFHGZKHQWKH/('LQGLFDWHV ORZEDWWHU\RUDWOHDVWRQFHD\HDU Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 6\VWHP&RQ¿JXUDWLRQ6HWXS $OO 6\VWHP FRQ¿JXUDWLRQVHWXS LV GRQH RQ WKH &RPPDQG &HQWHU&KRRVHWKHPRGHWKDWEHVWVXLWV\RXUQHHGV NOTE: When using On/Off wall switch, the switch must EH LQ WKH 21 SRVLWLRQ WR SHUIRUP DOO FRQ¿JXUDWLRQ VHW ups at the command center. Cold Climate Option 7KH6LJQDWXUH&RPPDQG6\VWHPLVGHVLJQHGWRRSHUDWHLQ HLWKHU6WDQGLQJ3LORWRU,QWHUPLWWHQW3LORWPRGH 7KH 6WDQGLQJ 3LORW 0RGH LV EHVW IRU FROGHU FOLPDWHV when the pilot must remain on continuously to prevent FRQGHQVDWLRQDQGHQVXUHUHOLDEOHRSHUDWLRQ 7KH ,QWHUPLWWHQW 3LORW 0RGH LV LGHDO IRU PD[LPXP HI¿FLHQF\ LJQLWLQJ WKH SLORW RQO\ ZKHQ QHHGHG WR VWDUW \RXUVWRYHORZHULQJIXHOFRQVXPSWLRQDQGUHGXFLQJ\RXU FDUERQIRRWSULQW (LWKHUPRGHEHQH¿WVIURPWKHLQVWDQWDQHRXVEDWWHU\EDFNXS VR\RXQHYHUKDYHWRZRUU\DERXWDSRZHURXWDJH NOTE: The Signature Command System comes standard in the Intermittent Pilot mode, so you must follow the instructions below to switch to Standing Pilot Mode if needed. :KHQWKHPDVWHUVZLWFKLVLQWKH21SRVLWLRQ ³´ SUHVVLQJ WKH21EXWWRQDQGWKH2))EXWWRQRQWKH&RPPDQG&HQWHU VLPXOWDQHRXVO\ZLOOWRJJOHEHWZHHQHQDEOLQJDQGGLVDEOLQJ WKHVL[KRXUVKXWGRZQRSWLRQ $IWHUWKHDERYHRSHUDWLRQRQHEHHS IRUHQDEOLQJWKHVL[KRXU VKXWGRZQ RSWLRQ RU WZR EHHSV IRU GLVDEOLQJ WKH VL[KRXU VKXWGRZQRSWLRQ ZLOOEHJLYHQDVFRQ¿UPDWLRQ Remote Transmitter Learn Function (Default OFF) 7KH5)UHFHLYHUEXWWRQORFDWHGRQWKH&RQWURO%RDUGPXVW EHLQWKHRQSRVLWLRQEHIRUHWKHOHDUQIXQFWLRQFDQEHJLQ8VH SDSHUFOLSWRGHSUHVVEXWWRQ2QHEHHSIRU5)UHFHLYHU21RU WZREHHSVIRU5)UHFHLYHU2))ZLOOEHJLYHQDVFRQ¿UPDWLRQ 5HIHUWR)LJXUHIRUORFDWLRQ $IWHUWKH5)UHFHLYHULVRQKROGLQJWKH2))EXWWRQRQWKH &RPPDQG &HQWHU ZKLOH WXUQLQJ RQ WKH PDVWHU VZLWFK ZLOO DFWLYDWHWKHOHDUQIXQFWLRQIRUWKHWUDQVPLWWHU $IWHUWKHDERYHRSHUDWLRQWZREHHSVZLOOEHJLYHQDQGWKH JUHHQ/('RQWKH&RPPDQG&HQWHUZLOOÀDVKIRUVHFRQGV 'XULQJWKHVHFRQGVSUHVVWKH2))EXWWRQRQDWUDQVPLWWHU WR OHDUQ $QRWKHU WZR EHHSV ZLOO EH JLYHQ WR FRQILUP D VXFFHVVIXO OHDUQLQJ 5HIHU WR WUDQVPLWWHU LQVWUXFWLRQV IRU UHPRWHRSHUDWLRQV Intermittent/Standing Pilot Setup (Default intermittent) +ROGLQJWKH21EXWWRQRQWKH&RPPDQG&HQWHUZKLOHWXUQLQJ RQWKHPDVWHUVZLWFKZLOOWRJJOHEHWZHHQVWDQGLQJSLORWDQG LQWHUPLWWHQWSLORW Shutting Off the Standing Pilot (Temporary Shut Off) 7RVKXWRIIWKHVWDQGLQJSLORWIRUVHUYLFHRUVXPPHUVKXWGRZQ SUHVVDQGKROGWKH21EXWWRQRQWKH&RPPDQG&HQWHUIRU VHFRQGVZKHQWKHPDVWHUVZLWFKLVLQWKH21SRVLWLRQ ³´ DQGWKHPDLQEXUQHULVRII $IWHUWKHDERYHRSHUDWLRQRQHEHHS IRUVWDQGLQJSLORW RU WZREHHSV IRULQWHUPLWWHQWSLORW ZLOOEHJLYHQDVFRQ¿UPDWLRQ 1RWH3LORWZLOOUHVXPHWKHQH[WWLPHV\VWHPLVWXUQHGRQ Six-hour Safety Shutdown Option (Default ON) 7KHV\VWHPFRPHVSUHVHWIURPWKHIDFWRU\ZLWKDVL[ KRXU VKXWGRZQIURPLWVODVWFRPPDQGRIRSHUDWLRQ7KLVLVGRQHWR SUHYHQWWKHVWRYHIURPFRQWLQXLQJWRRSHUDWHLIXQDWWHQGHG <RXPD\GLVDEOHWKLVIHDWXUHLI\RXZLVK .H\&RPELQDWLRQVIRU6\VWHP6HWWLQJV NOTE: When On/Off wall switch is used, it must be in the On position to perform all system setups. NOTE: By disabling this feature, your stove may continue to operate unattended. Function Operation Default Setting ,QWHUPLWWHQW6WDQGLQJ3LORW6HWXS +ROG WKH 21 S EXWWRQ ZKLOH WXUQLQJ RQ WKH PDVWHU VZLWFK %HHSRQFHIRUVWDQGLQJSLORWWZLFHIRULQWHUPLWWHQWSLORW Intermittent Pilot 6WDQGLQJ3LORW7HPSHUDWXUH6KXWRII +ROGWKH21SEXWWRQVHFRQGV ZKHQWKHPDVWHUVZLWFKRQ the main burner is off) 5)5HPRWH5HFLHYHU2Q2II 3XVK WKH 5) UHFHLYHU 2Q2II EXWWRQ RQ WKH FRQWURO ERDUG %HHSRQFHIRU21DQGEHHSWZLFHIRU2)) Learn Remote Transmitter +ROG WKH 2)) T EXWWRQ ZKLOH WXUQLQJ RQ WKH PDVWHU VZLWFK (Beep twice then press any handheld remote button) +RXU6DIHW\6KXWGRZQ6HWXS 3UHVV WKH 21 S EXWWRQ DQG 2)) T EXWWRQ VLPXOWDQHRXVO\ %HHSRQFHIRU21WZLFHIRU2)) 37 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 5)2)) 21 3-90-20306760 Operating instructions Turning on the stove 7XUQRQWKHPDVWHUVZLWFKDQGZDLWIRUDEHHS3UHVVWKH21 EXWWRQRQWKH&RPPDQG&HQWHURUWXUQRQZDOOVZLWFK3LORW ZLOOOLJKWDQGEXUQHUZLOOFRPHRQ+LJKVHWWLQJRUODVWPHPRU\ VHWWLQJ 6HH7XUQLQJ2II6WRYHEHORZ )RUPHPRU\IHDWXUH Pilot Safety Lockout Function ,IWKHSLORWGRHVQ¶WOLJKWDIWHUVSDUNLQJIRUVHFRQGVSLORWWULDO ORFNRXWKDSSHQV7KH/('RQWKH&RPPDQG&HQWHUÀDVKHV *UHHQRQFHHYHU\VHFRQGVXQWLOUHVHW Command Center Operations 7KH IROORZLQJ IXQFWLRQV DUH DYDLODEOH RQ WKH &RPPDQG &HQWHU Self Diagnostics Chart 7KH&RPPDQG&HQWHUKDVDVHOIGLDJQRVWLF/('HQDEOLQJ you to troubleshoot problems and potentially avoid a service FDOO3OHDVHUHIHUWRWKHFKDUWVEHORZIRULQGLFDWRUUHIHUHQFH ,IWKHSLORWÀDPHLVORVWGXULQJQRUPDORSHUDWLRQWKHV\VWHP ZLOOWU\WKUHH WLPHVWRUHOLJKWDIWHUWKUHH IDLOXUHVÀDPH ORVV ORFNRXW KDSSHQV 7KH /(' RQ WKH &RPPDQG &HQWHU ÀDVKHV5HG*UHHQRQFHHYHU\VHFRQGVXQWLOUHVHW Fault LED Indication &RQYHUVLRQ&RYHU0LVVLQJ 2QH5('HYHU\VHFRQGV 6SDUN)DLO 7ZR5('HYHU\VHFRQGV )ODPH(UURU6HQVRU6LJQDO 7KUHH5('HYHU\VHFRQGV Pilot Lockout - Trial )RXU5('HYHU\VHFRQGV 3LORW/RFNRXW)ODPH/RVV )LYH5('HYHU\VHFRQGV 7XUQLQJWKHPDVWHUVZLWFKRQWKH&RPPDQG&HQWHUWRWKHRII SRVLWLRQWKHQ21DJDLQZLOOUHVHWWKHV\VWHP Low Battery 2QH5('HYHU\VHFRQGV 1RRU/RZ7KHUPRSLOH3RZHU 7ZR5('HYHU\VHFRQGV Flame Height Control 3UHVVWKH21EXWWRQ RQWKH&RPPDQG&HQWHU RQFHWRWXUQ RQWKHPDLQEXUQHUZLWKPD[LPXPÀDPHKHLJKW 9DFFXP6ZLWFK)DLOHG 3RZHU 2QH5('HYHU\VHFRQGVXQWLO 9HQW2QO\ reset 3UHVV WKH 2)) EXWWRQ WR GHFUHDVH ÀDPH KHLJKW 7KH ¿UVW WZRSUHVVHVZLOOGHFUHDVHWKHÀDPHKHLJKWWRPHGLXPDQG ORZ7KHWKLUGSUHVVRQ2))ZLOOWXUQRIIWKHPDLQEXUQHU,Q VWDQGLQJSLORWFRQ¿JXUDWLRQWKHSLORWZLOOVWD\LQLQWHUPLWWHQW SLORWFRQ¿JXUDWLRQWKHSLORWZLOOEHVKXWRII Function Operation 3RZHU8S )OLS WKH PDVWHU VZLWFK WR WKH 21 ± position to power up the system 6WRYH21 3UHVVWKH21VEXWWRQRQWKH&RPPDQG Center or turn on wall switch to turn the stove on 6WRYH2)) /HDUQLQJ *5((1ÀDVKHVHYHU\VHFRQG (for 10 seconds) $&3RZHU2Q *5((1VROLG NOTE: Due to the sensitive temperature monitoring components in the transmitter, it is necessary to allow the transmitter to stabilize to room temperature before accurate room temperatures are displayed. If the transmitter is activated from a severe cold condition, allow 15 minutes for accurate temperature readings to appear on the LCD display. ! )OLS WKH PDVWHU VZLWFK WR WKH 2)) R SRVLWLRQ25SUHVVWKH2))WEXWWRQWLPHV 25IRU0HPRU\2IIKROGWKH2))WEXWWRQ 3 seconds, or turn off wall switch WARNING 7XUQDSSOLDQFH2)) DWWKH0DVWHU6ZLWFK LI\RXDUHDZD\ IURP\RXUKRXVHIRUDQH[WHQGHGSHULRGRIWLPH1HYHUOHDYH DQ\WKLQJRQWRSRIWKHVXUIDFHRIWKHWUDQVPLWWHU )ODPH +HLJKW 3UHVVWKH21VEXWWRQRQFHWRWXUQRQWKH 8S VWRYHZLWKPD[LPXPÀDPHKHLJKW Function Areas of the LCD Display )LJXUHVKRZVWKHGLVSOD\RIWKH76)6&/&' )ODPH+HLJKW 3UHVVWKH2))WEXWWRQWRORZHUWKHÀDPH Down KHLJKWWR0HGLXPDQG/RZ Information Bar The information bar shows the room temperature, the ³VHQGLQJVLJQDO´UDGLRLFRQWKHORZEDWWHU\LQGLFDWLRQLFRQ WKHFKLOGSURRILFRQDQGWKHÀDPHLFRQ7KLVDUHDGRHVQ¶W KDYHWRXFKEXWWRQV Turning the Stove Off 7KHUHDUHWKUHHZD\VWRWXUQWKHVWRYHRII )OLSWKHPDVWHUVZLWFKWRWKHRII ³2´ SRVLWLRQ 7KLVZLOO WXUQWKHHQWLUHV\VWHP2)) 3UHVVWKH2))EXWWRQWR0HGLXP/RZWKHQ2II +ROG WKH 2)) EXWWRQ DQ\WLPH IRU WKUHH VHFRQGV RU E\ WXUQLQJ RII WKH ZDOO VZLWFK 7KHVH WZR FRPPDQGV RI 2))DUH 0HPRU\2II WKHV\VWHPZLOOUHPHPEHUDOOODVW VHWWLQJV EHIRUH WXUQLQJ RII 7KH QH[W WLPH WKH VWRYH LV WXUQHG RQ DOO VHWWLQJV ZLOO UHVXPH7R UHVHW FKDQJH WR WKH GHVLUHG VHWWLQJV DQG VKXW RII E\ XVLQJ WKH 0HPRU\ 2IIFRPPDQGVDQGWKHV\VWHPZLOOEHUHVHWWRWKRVHQHZ VHWWLQJV 38 • The room temperature will always be shown after SRZHUXS,WGLVSOD\VWKHURRPWHPSHUDWXUHIURP) WR)³/R´DQG³+,´ZLOOEHGLVSOD\HGZKHQWKHURRP WHPSHUDWXUH LV ORZHU WKDQ ) RU KLJKHU WKDQ ) UHVSHFWLYHO\ Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 • The radio icon will be shown when the transmitter is VHQGLQJDVLJQDO Initialization and Setting up / Installing Batteries )LJXUH 60) • The low battery indication icon will be shown when the EDWWHU\YROWDJHLVORZ • The child-proof icon will be shown when the child-proof PRGHLVDFWLYDWHG The remote transmitter has two battery compartments, one RQHDFKHQGRIWKHWUDQVPLWWHU$OZD\VFKDQJHDOOIRXU batteries at the same time. To install batteries, 7KHÀDPHLFRQLQGLFDWHVWKHFXUUHQWÀDPHKHLJKW±2II /RZ0HGLXPDQG+LJK 3UHVVGRZQWKHEDWWHU\GRRUWDEDQGSXOORXWWRUHPRYH WKHEDWWHU\GRRU Touch Area The touch area contains all touch buttons to control the WUDQVPLWWHU ,W FRQVLVWV RI WZR FDWHJRULHV PHQXV DQG DGMXVWPHQWDUURZV7KHEOXH/('EDFNOLJKWOLJKWVXSIRU VHFRQGVZKHQDQ\RIWKHWRXFKEXWWRQVLVSUHVVHG ,QVWDOO WKH EDWWHULHV DV LQGLFDWHG LQVLGH WKH EDWWHU\ FRPSDUWPHQWV 7KHPHQXVLQFOXGH7,0(57+(502/,*+7)$1DQG $8; 7KH DGMXVWPHQW DUURZV LQFOXGH 21XS DQG 2))GRZQ 7KHLUGHIDXOWIXQFWLRQLVWRDGMXVWWKHÀDPHKHLJKW:KHQ D EXWWRQ IURP WKH PHQX LV SUHVVHG WKH 21XS DQG 2))GRZQ EXWWRQV ZLOO WHPSRUDULO\ EHFRPH DGMXVWPHQW FRQWUROV IRU WKH VHOHFWHG LWHP :KHQ WKH DGMXVWPHQW LV GRQH WKH 21XS DQG 2))GRZQ EXWWRQV JR EDFN WR ÀDPHKHLJKWFRQWUROOHUDJDLQ &ORVHWKHEDWWHU\GRRUE\VQDSSLQJLQSODFH :KHQDOOfour batteries are installed, the transmitter will LQLWLDOL]HIRUVHFRQGVDQGWKHQLVUHDG\IRUXVH 7KH EDWWHULHV VKRXOG EH UHSODFHG HYHU\ PRQWKV RU ZKHQWKHORZEDWWHU\LFRQLQGLFDWRULVGLVSOD\HG Battery Door Tabs Logo Bar 7KH/RJR%DUFRQWDLQVWKHEUDQGORJR6LJQDWXUH&RPPDQG 6\VWHP Information Bar )LJXUH5HSODFLQJWKHEDWWHU\ Menus Changing Temperature Unit When batteries are installed in the transmitter, all available LFRQVRQWKH/&'ZLOOEHWXUQHGRQWKHQEHFOHDUHG $GMXVWPHQW Controls 7RXFK$UHD 7KH/&'ZLOOGLVSOD\WHPSHUDWXUHXQLW)8VH21¨WRWRJJOH WKHXQLWVEHWZHHQ)DQG&ZLWKLQWKH¿UVWVHFRQGV The transmitter enters Manual Mode 7KH/&'GLVSOD\VURRPWHPSHUDWXUHZLWKWKHFKRVHQXQLW /RJR Bar )LJXUH)XQFWLRQDODUHDVRI/&''LVSOD\ 39 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Setting Privacy Code on Transmitter )LJXUH 7KHUHPRWHWUDQVPLWWHUSULYDF\FRGHLVSUHVHWLQIDFWRU\,Q the event of activation or interference from other nearby WUDQVPLVVLRQV FKDQJH WKH FRGH XVLQJ WKH IROORZLQJ SURFHGXUHV OHDUQIXQFWLRQPXVWEHSHUIRUPHGDIWHUFKDQJLQJ WKHFRGH • 3UHVVWKH21DUURZEXWWRQDQGWKH 7,0(5 EXWWRQ DW WKH VDPH WLPH WR HQWHUSULYDF\FRGHVHWXSPRGH • The setup display is shown in the ¿JXUH 7KH IRXU GLJLWV RQ WKH WRS stand for the privacy code (as the DFWXDO ',3 VZLWFKHV RQ $PELHQW¶V SUHYLRXV UHPRWHV 7KH GHIDXOW YDOXHV RI WKH IRXU GLJLWV ZLOO EH DOO ³´ 21 • 7KH ¿UVW GLJLW ZLOO EH ÀDVKLQJ XSRQ HQWHULQJ WKH VHWXS PRGH 3XVK Figure 61 WKH 21 EXWWRQ WR WRJJOH LWV YDOXH EHWZHHQ ³´ 2)) DQG ³´ 21 DQG SXVK WKH ³2))´ EXWWRQWRMXPSWRWKHQH[WGLJLW7KHQH[WGLJLWZLOOWKHQ VWDUWÀDVKLQJDQGWKH¿UVWRQHVWRSVÀDVKLQJ6HWXSWKH IRXUGLJLWVWR\RXUFKRLFH • $IWHUVHWWLQJXSDOOWKHIRXUGLJLWVSXVK³2))´WR¿QLVKWKH SURFHVVDQGUHWXUQWRWKHSUHYLRXVPRGH • 7KH 6LJQDWXUH &RPPDQG FRQWURO ERDUG WKHQ QHHGV WR UHOHDUQWKHQHZVHWWLQJ Performing Learn Function • 7KH5)UHFHLYHUEXWWRQRQWKHFRQWUROERDUGLQWKHVWRYH PXVWEHLQWKH21SRVLWLRQEHIRUHWKHOHDUQIXQFWLRQFDQ EHJLQ:LWKWKH&RPPDQG&HQWHUPDVWHUVZLWFKLQWKH21 position, use paper clip to depress the recessed button on &RQWURO%RDUGRQHEHHSIRU5)UHFHLYHU21RUWZREHHSV IRU5)UHFHLYHU2)))LJXUH • +ROGLQJ WKH 2)) EXWWRQ RQ WKH &RPPDQG &HQWHU ZKLOH WXUQLQJRQWKHPDVWHUVZLWFKZLOODFWLYDWHWKHOHDUQIXQFWLRQ IRUWKHWUDQVPLWWHU)LJXUH • $IWHU WKH DERYH RSHUDWLRQ WZR EHHSV ZLOO EH JLYHQ DQG WKHJUHHQ/('RQWKH&RPPDQG&HQWHUZLOOÀDVKIRU VHFRQGV • 'XULQJ WKH VHFRQGV SUHVV WKH 2)) EXWWRQ RQ WKH WUDQVPLWWHU WR OHDUQ$QRWKHU WZR EHHSV ZLOO EH JLYHQ WR FRQ¿UPDVXFFHVVIXOOHDUQLQJ)LJXUH Resetting the Transmitter ,IWKHWUDQVPLWWHULVQRWZRUNLQJSURSHUO\UHLQVWDOOWKHEDWWHULHV WRUHVHWWKHWUDQVPLWWHU • 3XOORXWDWOHDVWRQHRIWKHEDWWHULHV • 3UHVVDQ\NH\RQWKHVFUHHQWRGLVFKDUJH • :DLWIRUVHFRQGVDQGUHLQVWDOOWKHEDWWHULHV 3XVKLQJDQGKROGLQJDQ\NH\IRUPRUHWKDQVHFRQGVXQWLO WKHGLVSOD\UHIUHVKHVZLOODOVRUHVHWWKHWUDQVPLWWHU 40 21 /(' Master Switch 2)) Battery Door 5)5HFHLYHU 212)) )URQW3DQHO %H]HO2SWLRQDO CONTROL BOARD Figure 62 - Command center and control board ! WARNING Do not use two (2) or more remote control systems in the same area with the same privacy code setting, as they will communicate with each other. This may cause the appliances to malfunction. Functions and Operations General 7KH76)6&5HPRWH&RQWUROKDVIRXU RSHUDWLQJPRGHV 0DQXDO7LPHU7KHUPRVWDWLFDQG6PDUW0RGHWKHUPRVWDW 7KHFRQWUROV\VWHPFDQEHVHWWRWHPSHUDWXUHUDQJHEHWZHHQ )DQG)7KHEORZHUVSHHGDQGÀDPHKHLJKWFDQEH DGMXVWHGLQWKHPDQXDOWLPHUDQGWKHUPRVWDWLFPRGH7KH 6PDUW 0RGH WKHUPRVWDW ZLOO DXWRPDWLFDOO\ DGMXVW ÀDPH KHLJKWDQGEORZHUVSHHGDFFRUGLQJWRWKHGLIIHUHQFHEHWZHHQ 6HWDQG5RRPWHPSHUDWXUHV The transmitter will operate the remote receiver from 1 foot WR D PD[LPXP RI IHHW 7KH GLVWDQFH LV UHGXFHG ZKHQ EDWWHULHVDUHORZ Manual Mode )LJXUH ,QWKLVPRGHWKH7,0(5EXWWRQDQGWKH7+(502EXWWRQZLOO RQO\GLVSOD\³7,0(5´DQG³7+(502´UHVSHFWLYHO\ZLWKRXW VKRZLQJ WKH WLPH DQG WKH 6(7 WHPSHUDWXUH 3UHVVLQJ WKH 21XSDQG2))GRZQEXWWRQVZLOOFKDQJHWKHÀDPHKHLJKW LIQRQHRIWKHPHQXEXWWRQV 7,0(57+(502/,*+7)$1 $8; DUHSUHVVHGDQGÀDVKLQJ • 3UHVVWKH21XSEXWWRQWRWXUQRQWKHVWRYH7KHÀDPH LFRQRQWKH/&'GLVSOD\V+LJK Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 • 3UHVV WKH 2))GRZQ EXWWRQ WR GHFUHDVH WKH ÀDPH KHLJKW DQG WXUQRIIWKHVWRYH:KHQWKH2)) down button is pressed for three WLPHV WKH ÀDPH LFRQ FKDQJHV IRUP +LJK WR 0HGLXP WR /RZ WKHQWR2II • ,IWKH2))EXWWRQLVKHOGIRUPRUH WKDQ VHFRQGV DW DQ\ ÀDPH KHLJKWWKHVWRYHZLOOEHWXUQHGRII DQGWKHÀDPHLFRQGLVDSSHDUV • 6OLGLQJXSDQGGRZQRQWKHDUURZ buttons can also turn on or turn )LJXUH RIIWKHVWRYH • ,I WKH VWRYH LV VKXW RII XVLQJ WKH DERYH PHWKRGV LQ DQG DOO WKH VHWWLQJV ZLOO EH UHPHPEHUHG DQG ZLOO EH UHVXPHGQH[WWLPHWKHVWRYHLVWXUQHGRQ 0HPRU\2II Timer Mode ()LJXUH 3UHVVWKH7,0(5EXWWRQWRHQWHUWLPHUPRGH7KHVWRYHZLOO VWD\ RQ IRU D SHULRG RI WLPH DV VSHFL¿HG E\ WKH WLPHU DQG then be shut off by the transmitter when the timer counts GRZQWR]HUR Thermostat Mode )LJXUH NOTE: The Command Center buttons will disable when thermostat is being used. 3UHVVWKH7+(502EXWWRQWRVHWWKH WUDQVPLWWHULQWKHUPRVWDWPRGH7KH transmitter will automatically turn on the stove when the room temperature is below the set temperature and turn off the appliance when the room temperature is above the set WHPSHUDWXUHZLWKLQRQHGHJUHH :KHQ WKH 7+(502 EXWWRQ LV pressed, the Set temperature appears in the frame of the button DQGÀDVKHV 8VH 21XS DQG 2))GRZQ to increase or decrease the Figure 65 6HW WHPSHUDWXUH LQ GHJUHH LQFUHPHQWV EHWZHHQ GHJUHHV DQG GHJUHHV Slide up and down on the arrow buttons will increase or GHFUHDVHWKH6HW7HPSHUDWXUHLQGHJUHHVLQFUHPHQWV 3UHVV WKH 7+(502 EXWWRQ DJDLQ WR FRQ¿UP WKH 6HW 7HPSHUDWXUH7KHWUDQVPLWWHUZLOOVHQGRXWDQ2QVLJQDO RUDQ2IIVLJQDOGHSHQGLQJRQWKHUHODWLRQVKLSEHWZHHQ WKH6HWWHPSHUDWXUHDQGWKH5RRPWHPSHUDWXUH • :KHQ WKH 7,0(5 EXWWRQ LV SUHVVHG WKH 6HW 7LPH appears in the frame of the button DQGÀDVKHV • 8VH 21XS DQG 2))GRZQ WR increase or decrease the Set 7LPH LQ PLQ LQFUHPHQWV EHWZHHQWR6OLGLQJXS and down on the arrow buttons will increase or decrease the Set 7LPHLQKRXULQFUHPHQWV 7KHÀDVKLQJVWRSVDQGWKH21XSDQG2))GRZQEXWWRQV EHFRPHÀDPHKHLJKWFRQWUROOHUDJDLQ7KHÀDPHKHLJKW ZLOO WKHQ VWD\ DV VHW XS E\ WKH 21XS DQG 2))GRZQ EXWWRQV 3XVK WKH 7,0(5 EXWWRQ DJDLQ WR FRQ¿UP WKH 6HW 7LPH WKH WUDQVPLWWHUVHQGVDQ21VLJQDOWR WXUQRQWKHVWRYH or • • • 7KHÀDVKLQJVWRSVDQGWKH21XS )LJXUH DQG 2))GRZQ EXWWRQV EHFRPH ÀDPH KHLJKW FRQWUROOHU DJDLQ7KHÀDPHKHLJKWZLOOWKHQVWD\DVVHWXSE\WKH 21XSDQG2))GRZQEXWWRQV 7KH7,0(5EXWWRQFDQEHXVHGZKHQWKHWUDQVPLWWHULV LQ0DQXDO0RGHRULQ7KHUPRVWDW0RGH,QERWKPRGHV the stove will be shut down completely when the timer FRXQWVGRZQWR]HUR 7RH[LW7LPHU0RGH\RXFDQGRRQHRIWKHIROORZLQJ • 3XVKDQGKROGWKH7,0(5EXWWRQIRUVHFRQGV • 8VHWKH2))GRZQEXWWRQVWRGHFUHDVHWKH6HW7LPHWR ]HUR • 6OLGH GRZQ RQ WKH DUURZ EXWWRQV WR H[LW 7,0(5 PRGH DQGVKXWRIIWKHVWRYH 41 7RH[LW7KHUPRVWDW0RGH D SXVKDQGKROGWKH7+(502EXWWRQVIRUVHFRQGV E VOLGHGRZQRQWKHDUURZEXWWRQVWRH[LW7KHUPRVWDW PRGHDQGVKXWRIIWKHVWRYH Smart Mode® Thermostat Option for Thermostat Mode )LJXUH 3UHVV DQG KROG WKH 7+(502 EXWWRQ DQG WKH 2183 EXWWRQ at the same time for 3 seconds WRWRJJOHEHWZHHQ6PDUW0RGH WKHUPRVWDW DQG WKH UHJXODU 7KHUPRVWDW 0RGH 7KH LFRQ ³6PDUW0RGH´ZLOODSSHDUXQGHU WKH 6HW 7HPSHUDWXUH 7KH transmitter will automatically DGMXVW WKH ÀDPH KHLJKW DFFRUGLQJ WR WKH GLIIHUHQFH between the set temperature DQG WKH URRP WHPSHUDWXUH 7KHUHLVQRPDQXDOÀDPHKHLJKW Figure 66 DGMXVWPHQW7KHIDQVSHHGZLOO DOVRDXWRPDWLFDOO\DGMXVWLIWXUQHGRQ Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 Smart Mode Icon 3-90-20306760 127( WKHUH ZLOO D VHFRQG GHOD\ IRU WKH IODPH adjustment when the stove is turned on. :KHQ 6HW 7HPS LV ) RU KLJKHU WKDQ 5RRP 7HPS ÀDPHKHLJKWZLOOEHRQ+LJK ,IWKHEORZHULVWXUQHGRQXVLQJWKH)$1EXWWRQWKHEORZHU VSHHGZLOODGMXVWDXWRPDWLFDOO\ZKHQXVLQJ6PDUW0RGH thermostat (See Smart ModeWKHUPRVWDWVHFWLRQ :KHQ6HW7HPSLV)KLJKHUWKDQ5RRP7HPSÀDPH KHLJKWZLOOEHRQ0HGLXP )LJXUH Blower On Delay Time and Off Delay Time Setup :KHQ6HW7HPSLV)KLJKHUWKDQ5RRP7HPSÀDPH KHLJKWZLOOEHRQ/RZ +ROG WKH )$1 EXWWRQ IRU VHFRQGV XQWLO WZR QXPEHUV DSSHDURQWKH/&'VFUHHQ7KHOHIWQXPEHULVEORZHU2Q 'HOD\DQGWKHULJKWQXPEHULVEORZHU2II'HOD\7LPH :KHQ6HW7HPSLVHTXDOWR5RRP7HPSÀDPHKHLJKW GRHVQRWFKDQJH VWD\VRQORZ :KHQWKH¿UVWQXPEHULVÀDVKLQJXVHWKH21XSEXWWRQWR VHWWKHGHVLUHG2Q'HOD\7LPHIURPWRPLQ :KHQ 6HW7HPS LV ORZHU WKDQ 5RRP7HPS WKH VWRYH ZLOOEHVKXWRII 3UHVVWKH2))GRZQEXWWRQWRMXPSWRWKH2II'HOD\7LPH VHWXS :KHQ6HW7HPSLV)KLJKHUWKDQ5RRP7HPSDJDLQ WKHÀDPHKHLJKWZLOOEHRQ/RZ :KHQ WKH VHFRQG QXPEHU LV ÀDVKLQJ XVH WKH 21XS EXWWRQDJDLQWRVHWWKHGHVLUHG2II'HOD\7LPHIURPWR PLQ 7KH IDQ VSHHG IROORZV WKH ÀDPH KHLJKW LI WKH IDQ LV WXUQHGRQ To exit Smart Mode® thermostat and shut off the stove; 3XVKDQGKROGWKH7+(502EXWWRQVIRUVHFRQGV2U 3UHVVWKH2))EXWWRQ2U 3UHVVWKH2))GRZQEXWWRQDJDLQWR¿QLVKWKHVHWXSDQG WKHQHZVHWWLQJVZLOOEHWUDQVPLWWHGWRWKHUHFHLYHU 7KHGHIDXOWVHWWLQJVDUHPLQXWHVIRUWKH2Q'HOD\7LPH DQGPLQXWHVIRUWKH2II'HOD\7LPHDVVKRZQ 6OLGHGRZQRQWKHDUURZEXWWRQV To shut off the Smart Mode thermostat option and return WRUHJXODUWKHUPRVWDWPRGHSUHVVDQGKROGWKH7+(502 EXWWRQDQGWKH2183EXWWRQDWWKHVDPHWLPHIRUVHFRQGV DJDLQ Blower Speed Control )LJXUH 127(%ORZHUZLOORQO\ZRUNZLWKÀDPHRQ The blower speed control function LV XVHG WR DGMXVW WKH VSHHG RI WKH EORZHU FRQQHFWHG WR WKH 6LJQDWXUH &RPPDQG 6\VWHP 7KHUH DUH IRXU VSHHG OHYHOV 2II /RZ 0HGLXP +LJK Figure 68 3UHVV WKH )$1 EXWWRQ WR HQWHU WKHEORZHUVSHHGFRQWUROPRGH 7KHIDQLFRQZLOOVWDUWÀDVKLQJ 3UHVVWKH21XSDQG2))GRZQ EXWWRQWRLQFUHDVHGHFUHDVHWKH EORZHUVSHHG 3UHVV WKH IDQ EXWWRQ DJDLQ WR )LJXUH FRQ¿UPWKHVSHHGVHWWLQJ,IWKH VWRYHLVRQWKHEORZHUVSHHGZLOOWDNHHIIHFWULJKWDZD\ LIWKHVWRYHLVRIIWKHUHFHLYHUZLOOUHPHPEHUWKLVVHWWLQJ DQGWKHEORZHULVVWLOORII VHHEORZHU2Q'HOD\DQG2II 'HOD\LQWKHQH[WVHFWLRQ $IWHUWKHVLJQDOLVVHQWWKH21XSDQG2))GRZQEXWWRQV EHFRPHÀDPHKHLJKWFRQWUROOHUDJDLQ :KHQ WKH IDQ EXWWRQ LV ÀDVKLQJ VOLGH XS DQG GRZQ RQ WKH DUURZ EXWWRQV ZLOO WXUQ WKH EORZHU VSHHG WR +LJK RU 2II GLUHFWO\ ZLWKRXW SUHVVLQJ WKH IDQ EXWWRQ DJDLQ WR FRQ¿UP 42 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Setting up Blank Screen or Constant Display in Idle )LJXUH There is an option to set up how the LCD displays and IXQFWLRQV ZKHQ WKH WUDQVPLWWHU LV LQ LGOH 7KHUH DUH WZR FKRLFHV $ 0RGH:KHQWKHWUDQVPLWWHULVLQLGOHWKHLFRQVLQWKH ³WRXFK DUHD´ WLPHU WKHUPRVWDW EORZHU OLJKW DQG$8; ZLOOGLVDSSHDUDVVKRZQLQWKH¿JXUHRQWKHOHIW:KHQ any of the touch buttons is pressed, those icons will DSSHDUDQGDUHUHDG\WRRSHUDWH GHIDXOW % 0RGH 7KH WUDQVPLWWHU DOZD\V GLVSOD\V DOO DYDLODEOH LFRQVVKRZLQJFXUUHQWVWDWXVRIWLPHUWKHUPRVWDWEORZHU OLJKWDQG$8;DVVKRZQLQWKH¿JXUHRQWKHULJKW 3UHVV7,0(5DQG7+(502EXWWRQVDWWKHVDPHWLPHIRU VHFRQGVWRWRJJOHEHWZHHQ$ DQG% :KHQ WKH FXUUHQW VHWWLQJ LV$ WRXFK DQ\ SODFH LQ WKH WRXFKDUHDWREULQJXSWKHLFRQVWKHQSUHVV7,0(5EXWWRQ DQG 7+(502 EXWWRQ DW WKH VDPH WLPH IRU VHFRQGV 7KHEDFNOLJKWZLOOÀDVKRQFHWRLQGLFDWHWKDWWKHVHWWLQJ KDVFKDQJHGWR% :KHQ WKH FXUUHQW VHWWLQJ LV % SUHVVLQJ7,0(5 EXWWRQ DQG7+(502EXWWRQDWWKHVDPHWLPHIRUVHFRQGVZLOO VZLWFKWR$ 0RGH7KHWRXFKDUHDLFRQVZLOOGLVDSSHDU Thermal Shutdown :KHQ WKH DPELHQW WHPSHUDWXUH LV PRUH WKDQ ) WKH WUDQVPLWWHUZLOOWXUQRIIWKHVWRYH • 7KH/&'ZLOOGLVSOD\³+,´ • The Transmitter will not function until the room WHPSHUDWXUHKDVGURSSHGEHORZGHJUHH)DKUHQKHLW Low Temperature Condition :KHQ WKH DPELHQW WHPSHUDWXUH LV OHVV WKDQ GHJUHHV )DKUHQKHLWWKH/&'ZLOOGLVSOD\³/2´DQG126,*1$/ZLOO EHVHQWWRWXUQRQWKHDSSOLDQFH $OOIXQFWLRQVVWLOOUHPDLQWKHVDPHIRUERWK0DQXDO Mode and Thermostat Mode Child-proof Protection The child-proof icon will be shown when the FKLOGSURRI PRGH LV DFWLYDWHG E\ SUHVVLQJ WKH 21EXWWRQDQGWKH2))EXWWRQDWWKHVDPHWLPH IRUWKUHHVHFRQGV • (QWHU FKLOGSURRI PRGH E\ SUHVVLQJ DQG KROGLQJ ERWK WKH 21 EXWWRQ DQG WKH 2)) EXWWRQ VLPXOWDQHRXVO\ IRU VHFRQGV 7KH Childproof indicator will be shown on the /&' • 'HDFWLYDWHFKLOGSURRIPRGHE\SUHVVLQJDQG KROGLQJ WKH 21 EXWWRQ DQG WKH 2)) EXWWRQ VLPXOWDQHRXVO\ IRU VHFRQGV DJDLQ 7KH &KLOGSURRI LQGLFDWRUGLVDSSHDUVRQWKH/&' • 7KHWUDQVPLWWHUFDQQRWEHRSHUDWHGLQFKLOGSURRIPRGH Using the Mounting Base )LJXUH 7KHWUDQVPLWWHUFRPHVZLWKDPRXQWLQJEDVHZKLFKDOORZV \RXWRKDQJWKHWUDQVPLWWHURQWKHZDOO 6HFXUHWKHPRXQWLQJEDVHRQWKHZDOOZLWKVXSSOLHGVFUHZV )RUEHVWYLHZLQJDQJOHPDNHLWWKHVDPHKHLJKWDV\RXUH\HV +DQJWKHWUDQVPLWWHURQWKHKRRNRIWKHPRXQWLQJEDVHWKHQ SXVKGRZQVRWKHWUDQVPLWWHULVÀXVKWRWKHPRXQWLQJEDVH )LJXUH Safety Features Low Battery Detection When low battery condition occurs, the transmitter will WXUQRIIWKHVWRYH %DWWHU\YROWDJHLVFKHFNHGHYHU\RQHPLQXWH:KHQWKH EDWWHU\YROWDJHLVORZWKH/&'GLVSOD\VDORZEDWWHU\LFRQ ZKLFKZLOOH[LVWLQDOOPRGHV • 7KHWUDQVPLWWHUZLOOQRWRSHUDWHZLWKORZEDWWHU\YROWDJH &KDQJH WKH EDWWHULHV EHIRUH WKH EDWWHULHV EHFRPH WRR ZHDNIRUQRUPDORSHUDWLRQV )LJXUH8VLQJWKH0RXQWLQJ%DVH Power On Initialization $IWHUWKHSRZHURQLQLWLDOL]DWLRQWKHWUDQVPLWWHUVHQGVDVLJQDO WRWXUQRIIWKHVWRYH 43 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Troubleshooting Signature Command System - Troubleshooting the Transmitter Symptom Causes Action Battery icon on LCD on transmitter Low Battery 5HSODFHEDWWHULHV&KDQJHEDWWHULHVHYHU\ PRQWKV LCD display is blank Low Battery Check battery installation or replace batteries /&'GLVSOD\VKRZV³IXQQ\´GLVSOD\ Low Battery 5HVHWWKHWUDQVPLWWHU VHH³5HVHWWLQJWKH 7UDQVPLWWHU´VHWWLQJ $SSOLDQFHGRHVQRWFRPHRQ The transmitter did not match with the UHFHLYHU Make sure the transmitter has learned to the UHFHLYHU Transmitter measures temperature H[FHHGLQJ)DQGVKRZV³+,´RQ/&' Move transmitter to a cooler place and wait XQWLOWHPSHUDWXUHGURSVEHORZ) Distance between the transmitter and receiver is more than 30 feet 0DNHVXUHWKHRSHQLQJGLVWDQFHLVOHVVWKDQ IHHW Blower is not on after the stove is turned on %ORZHUVHWWLQJLVRII 3UHVV)$1NH\WRVHOHFWIDQVSHHGGHVLUHG %ORZHUGHOD\VHWWLQJLVVHWWRRKLJK 3UHVVDQGKROG)$1NH\WRVHWGHVLUHG21 2))GHOD\V7KLVLVGRQHLQPLQXWHV General Troubleshooting OPERATION Install batteries and/or plug in the AC board FAULT No beep in about 8 seconds A Using battery? Make sure Command Center and the control board are connected by a 2 feet or 15 feet cable After the beep Flip the master switch (rocker switch) to the ON position Press the ON button on the Command Center No beep or no sound from the valve indicating pilot solenoid open C Sparking doesn’t continue D Main burner doesn’t light 44 B No sparking on the pilot Pilot doesn’t light ACTION DIAGNOSIS E F Check NG/LP conversion cap and control board connections Check pilot connections Battery polarity wrong? Re-install batteries Battery voltage low? Change batteries AC plug is plugged to AC mains? Plug the AC plug to AC mains The 5-pin connector on the AC board broken or bent? Repair or replace the AC Board LED on the Command Center does not show solid green? Replace the AC Board Check valve connections Check grounding Check power supply (go through A ) Replace the Control Board or Command Center Go through B Sparking is happening elsewhere (under the pilot), re-install/replace the pilot The Control Board is having interference from the surrounding metal (Ground) Check gas supply Go through E Go through C The sensor on the pilot is not in the flame (pilot flame too small)? Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 Re-install the Control Board, move it around or change the Control Board Sparking is not in the path of gas flow, adjust sparker position or replace the pilot Adjust sensor position or replace the pilot 3-90-20306760 Burner, Pilot and Control Compartment ! WARNING 7XUQRIIJDVEHIRUHVHUYLFLQJVWRYH,WLVUHFRPPHQGHGWKDW DTXDOL¿HGVHUYLFHWHFKQLFLDQSHUIRUPWKHVHFKHFNXSVDW WKHEHJLQQLQJRIHDFKKHDWLQJVHDVRQ .HHS WKH FRQWURO FRPSDUWPHQW VWRQHV DQG EXUQHU DUHDV VXUURXQGLQJWKHVWRQHVFOHDQE\YDFXXPLQJRUEUXVKLQJDW OHDVWWZLFHD\HDU0DNHVXUHWKHEXUQHUSRUWLQJSLORWDLU RSHQLQJDQGEXUQHUDLURSHQLQJDUHIUHHRIREVWUXFWLRQVDW DOOWLPHV Pilot Flame 7KH ÀDPHV IURP WKH SLORW VKRXOG EH YLVXDOO\ FKHFNHG DV VRRQDVWKHKHDWHULVLQVWDOOHGDQGSHULRGLFDOO\GXULQJQRUPDO RSHUDWLRQ7KHSLORWÀDPHPXVWDOZD\VEHSUHVHQWZKHQWKH VWRYHLVLQRSHUDWLRQ)LJXUH7KHSLORWÀDPHKDVWKUHH GLVWLQFWÀDPHVRQHHQJXO¿QJWKHVHQVRURQHHQJXO¿QJWKH WKHUPRSLOHDQGWKHRWKHUUHDFKLQJWRWKHPDLQEXUQHU Burner ,QVSHFWDUHDDURXQGWKHLQMHFWRU5HPRYHDQ\OLQWRUIRUHLJQ PDWHULDOZLWKDEUXVKRUYDFXXP Burner Flame 7KHÀDPHVIURPWKHEXUQHUVKRXOGEHYLVXDOO\FKHFNHGDV VRRQDVWKHKHDWHULVLQVWDOOHGDQGSHULRGLFDOO\GXULQJQRUPDO RSHUDWLRQ,QQRUPDORSHUDWLRQDWIXOOUDWHDQGDIWHURSHUDWLQJ IRUDERXWWRPLQXWHVWKHÀDPHVKRXOGEH\HOORZ ,I WKH ÀDPH LV EOXH DQG FDQGOHOLNH LQ DSSHDUDQFH DGMXVW JODVVRUDGGPRUHJODVVRYHUSRUWV 127(7KHW\SHRILQVWDOODWLRQYHQWV\VWHPFRQ¿JXUDWLRQ DQGZLQGHIIHFWVPD\FDXVHWKHÀDPHSDWWHUQVWRYDU\ Sensor Thermopile )LJXUH3LORW)ODPH 45 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Valve Conversion - SDDVT Series Models 7XUQFRQWURONQREWRWKH2))SRVLWLRQDQGVKXWRIIWKH JDVVXSSO\WRWKHYDOYH Fuel conversion WARNING $OORZWKHYDOYHWRFRROWRURRPWHPSHUDWXUH 5HPRYHWKHEODFNSURWHFWLRQFDSE\KDQG )LJXUH ,/ () 7KLVFRQYHUVLRQNLWVKDOOEHLQVWDOOHGE\DTXDOL¿HGVHUYLFH DJHQF\LQDFFRUGDQFHZLWKWKHPDQXIDFWXUHU¶VLQVWUXFWLRQV and all applicable codes and requirements of the authority KDYLQJMXULVGLFWLRQ,IWKHLQIRUPDWLRQLQWKHVHLQVWUXFWLRQV LVQRWIROORZHGH[DFWO\D¿UHH[SORVLRQRUSURGXFWLRQRI FDUERQPRQR[LGHPD\UHVXOWFDXVLQJSURSHUW\GDPDJH SHUVRQDOLQMXU\RUORVVRIOLIH7KHTXDOL¿HGVHUYLFHDJHQF\ LV UHVSRQVLEOH IRU WKH SURSHU LQVWDOODWLRQ RI WKLV NLW7KH installation is not proper and complete until the operation RIWKHFRQYHUWHGDSSOLDQFHLVFKHFNHGDVVSHFL¿HGLQWKH PDQXIDFWXUHU¶VLQVWUXFWLRQVVXSSOLHGZLWKWKHNLW () ! ,/ ! CAUTION 7KHJDVVXSSO\VKDOOEHVKXWRIISULRUWRGLVFRQQHFWLQJWKH HOHFWULFDOSRZHUEHIRUHSURFHHGLQJZLWKWKHFRQYHUVLRQ )LJXUH )LJXUH )LJXUH ,QVHUWDRUPP$OOHQZUHQFKLQWRWKHKH[DJRQDONH\ ZD\RIWKHVFUHZ )LJXUH URWDWHLWFRXQWHUFORFNZLVH XQWLOLWLVIUHHDQGH[WUDFWLW • Check that the screw is clean and if necessary remove GLUW)OLSWKHVFUHZ )LJXUH OFF ON P IL NOTE: Do not over-tighten the screw. Recommended to grip the wrench by the short side. O H PILOT ADJ L I O T 8VLQJWKH$OOHQZUHQFKDVVKRZQLQ)LJXUHURWDWHWKH VFUHZFORFNZLVHDQGWLJKWHQXQWLOVQXJ *DV6XSSO\,QOHW Main *DV Line Shut off Valve )LJXUH$WWDFKWKHJDVOLQHWRWKHULJKWVLGHRIWKHYDOYH () Conversion Precautions %HIRUHSURFHHGLQJWXUQFRQWURONQRERQYDOYHWR2))DQG WXUQJDVVXSSO\2))7XUQ2))DQ\HOHFWULFLW\WKDWPD\EH JRLQJWRWKHDSSOLDQFH () ,/ Conversion Procedure 5HPRYHVWRYHIURQW/LIWVWRYHIURQWXSDQGWKHQVZLQJ ERWWRPRXWDQGDZD\WRGLVHQJDJHIURPWKHVWRYHERG\ 8QGR WKH ULJKW DQG OHIW ODWFKHV DW WKH WRS RI WKH JODVV IUDPH ,/ )LJXUH )LJXUH 3XOOWKHWRSHGJHRIWKHJODVVDQGIUDPHDVVHPEO\DZD\ IURPWKH¿UHER[IDFH3ODFHWKHDVVHPEO\RXWRIWKHZD\ RQDÀDWSDGGHGVXUIDFHVXFKDVDFRXQWHUSURWHFWHGE\ DWRZHO 5HPRYHWKHORJVHWIURPWKH¿UHER[ 46 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 9HULI\WKDWLIWKHFRQYHUVLRQLVIURP1*WR/3WKHVFUHZ PXVWEHUHDVVHPEOHGZLWKWKHUHGRULQJYLVLEOH )LJXUH 77) 5HSODFHWKHEODFNSURWHFWLRQFDS $OOHQZUHQFK () Natural Gas Configuration () LP Configuration ,QGH[WDE ,/ ,/ 6QDSULQJ 5HG2ULQJ9LVLEOH 5HG2ULQJ1279LVLEOH )LJXUH )LJXUH5HPRYHSLORWRUL¿FH NOTE: Check that also the pilot and main burner injectors are appropriate for the gas type. %XUQHU2UL¿FH&RQYHUVLRQ 3LORW2UL¿FH&RQYHUVLRQ /RFDWHSLORW )LJXUH 5HPRYH WKUHH QXWV RQ ERWWRP VLGH RI EXUQHU SDQ )LJXUH &DUHIXOO\UHPRYHHPEHUEHGE\WLOWLQJWKHULJKWVLGHXS DQGOLIWLQJRXWWRZDUGWKHULJKWVLGHRIWKHXQLW )LJXUH 5HSODFHSLORWRUL¿FH 5HPRYH SLORW KRRG E\ OLIWLQJ XS )LJXUH 'R QRW UHPRYHWKHVQDSULQJWRUHPRYHWKHSLORWKRRG Bottom View 5HPRYH1XW NOTE: It is not necessary to remove the pilot tube for conversion. 5HPRYHSLORWRUL¿FHZLWKDDOOHQZUHQFK )LJXUH ,QVWDOOWKHFRQYHUVLRQRUL¿FH 5HLQVWDOOSLORWKRRG%HVXUHWRDOLJQKRRGZLWKLQGH[WDE Pilot 5HPRYH1XWV Figure 815HPRYHWKUHH QXWVVHFXULQJHPEHUEHGLQSODFH 2UL¿FH Bracket Venturi Bracket )LJXUH/RFDWHSLORW Pilot hood Pilot bracket Pem Studs Figure 827LOWHPEHUEHGVOLJKWO\WRFRUUHFWO\SODFHRQYHQWXULDQG DLUVKXWWHU )LJXUH5HPRYHSLORWKRRG 47 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 5HPRYH LQMHFWRU RUL¿FH IURP OHIW EXUQHU EUDFNHW ZLWK D ZUHQFK8VHDEDFNXSZUHQFKWRSUHYHQWGDPDJH WRWKHPDQLIROG )LJXUH ,QVWDOOFRQYHUVLRQRUL¿FH 5HIHUWR7DEOH 7KH DLU VKXWWHU LV IDFWRU\ VHW DFFRUGLQJ WR 7DEOH DQG VKRXOG QRW QHHG DGMXVWPHQW 7KH DLU VKXWWHU RSHQLQJ PD\EHYHUL¿HGE\PHDVXULQJDVVKRZQLQ)LJXUH )LJXUH8VHWZRZUHQFKHVWRDYRLGGDPDJHWRPDQLIROG 2UL¿FH Bracket 2UL¿FH $LU6KXWWHU )LJXUH7KHDLUVKXWWHUVHWWLQJLV PP IURPWKHRUL¿FH EUDFNHWWRWKHHGJHRIWKHDLUVKXWWHU 48 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 SDVTSC Models 8VLQJ7RU[7GULYHURUVORWWHGVFUHZGULYHUUHPRYHDQG GLVFDUGWKHUHJXODWRUDQGUXEEHUJDVNHWLQWKHIDFHRIWKH YDOYH )LJXUH ,QVWDOO WKH QHZ UHJXODWRU ZLWK UXEEHU JDVNHW IURP WKH FRQYHUVLRQNLW0DNHVXUHWKHJDVNHWLVVHDWHGSURSHUO\ /RRVHQ WKH SLORH ¿WWLQJ DW WKH EDVH RI WKH SLORWH XVLQJ D ZUHQFK 5HPRYH WKH H[LVWLQJ SLORW RUL¿FH DQG UHSODFH ZLWK WKH SLORW RUL¿FH VKLSSHG ZLWK VWRYH XVLQJ D ÀDW KHDG VFUHZ GULYHU :KHQ UHSODFLQJ WKH SLORW IRU VHUYLFHSXUSRVHUHSODFHWKHHQWLUHSLORW &RQYHUW WKH FRQWURO ER[ E\ XVLQJ D VPDOO ÀDW KHDG VFUHZGULYHU/LIWWKHFRQYHUVLRQFDSIURPWKHFRQWUROER[ DQGUHSODFHZLWKQHZRQHPDUNHG/3%HVXUHWRSODFH FRUUHFWO\)LJXUH All Models 5HSODFH EXUQHU PDNLQJ VXUH YHQWXUL RQ ERWWRP RI HPEHU EHGDOLJQVZLWKRUL¿FHDQGLVVHDWHGSURSHUO\RQDLUVKXWWHU DVVHPEO\0DNHVXUHEXUQHULVVOLGLQWRSODFHDWDVOLJKWDQJOH DQGRSSRVLWHWRKRZLWZDVUHPRYHG:KHQEXUQHULVVOLGLQWR SODFH WKH WKUHH SHP VWXGV VKRXOG VOLGH GRZQ WKURXJK FOHDUDQFHKROHVLQWRWKHERWWRPRIWKHFRQWUROSDQHO 7KUHDG DQG WLJKWHQ ´ QXWV EDFN RQWR SHP VWXGV RQ XQGHUQHDWK VLGH RI FRQWURO SDQHO UHYHUVLQJ 6WHS VKRZQ LQ)LJXUH 5HIHUWR/RJ,QVWDOODWLRQVHFWLRQRIWKLVPDQXDOWRUHLQVWDOO ORJV 3ODFHFRQYHUVLRQODEHOVXSSOLHGZLWKNLWRQUDWLQJSODWH 5HSODFHJODVVDQGVWRYHIURQW 5HVWRUH JDV WR V\VWHP DQG UHOLJKW DSSOLDQFH DFFRUGLQJ WR /LJKWLQJ,QVWUXFWLRQVRQSDJH 6''97PRGHOV RUSDJH 6'976&PRGHOV /HDNFKHFNWKHV\VWHPXVLQJDJDVOHDNGHWHFWRUVROXWLRQ 5HJXODWRU 5HOLJKWWKHPDLQEXUQHULQERWKWKH³+,´DQG³/2´SRVLWLRQV WRYHULI\SURSHUEXUQHULJQLWLRQDQGRSHUDWLRQ &RQYHUVLRQLVFRPSOHWH 5XEEHUJDVNHW Figure 859DOYH5HJXODWRU Figure 86&RQYHUW&RQWURO%R[ 49 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 7DEOH,QMHFWRU2UL¿FH6L]H0DWUL[ Conversion to LP* Input (BTU/h) Model .LW SDDVT . SDVTSC 4604-011 2UL¿FH 3DUW Minimum 0D[LPXP PP 20308650 21,000 25,000 Conversion to Natural Gas Input (BTU/h) .LW Model SDDVT 4604-012 SDVTSC 4604-013 2UL¿FH 3DUW Minimum 0D[LPXP PP 4604-316 20,000 28,000 7DEOH$LU6KXWWHU$GMXVWPHQW Model 1DWXUDO*DV 1DWXUDO*DV +LJK$OWLWXGH LP 6''976'976& 2SHQ ´2SHQ ´2SHQ /3PRGHOVGRQRWQHHGUHRUL¿FHGXSWR¶ P DERYHVHDOHYHO 50 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Cleaning & Maintenance <RXU6WDUGDQFH*DVKHDWHUZLOOSURYLGH\HDUVRIVHUYLFHZLWK PLQLPDOXSNHHS7KHIROORZLQJSURFHGXUHVZLOOKHOSHQVXUH WKDW\RXUVWRYHFRQWLQXHVWRIXQFWLRQSURSHUO\ Annual System Inspection +DYHWKHHQWLUHKHDWHUDQGYHQWLQJV\VWHPLQVSHFWHGDQQXDOO\ E\DTXDOL¿HGJDVWHFKQLFLDQ5HSODFHDQ\ZRUQRUEURNHQ SDUWV Logset and Burner / Cleaning and Inspection &OHDQOLQHVV LV FULWLFDO WR WKH SURSHU IXQFWLRQ RI WKH KHDWHU 7KH ORJVHW DQG EXUQHU PXVW DOO EH NHSW IUHH RI GXVW DQG XQREVWUXFWHGE\GHEULV,QVSHFWWKHVHDUHDVEHIRUHHDFKXVH DQGFOHDQDVQHFHVVDU\ 7XUQWKHEXUQHU2))DQGOHWWKHKHDWHUFRROFRPSOHWHO\ EHIRUHFOHDQLQJ Remove the safety barrier and lift the stove front up and WKHQVZLQJWKHERWWRPRXWWRGLVHQJDJHLWIURPWKHKHDWHU VKHOO )LJXUH &DUHIXOO\ UHPRYH WKH JODVV DQG IUDPH DVVHPEO\ DQG SODFHLWRXWRIWKHZD\RQDÀDWSDGGHGVXUIDFHVXFKDV DFRXQWHUSURWHFWHGE\DWRZHO Cleaning the Glass ,WZLOOEHQHFHVVDU\WRFOHDQWKHJODVVSHULRGLFDOO\'XULQJ start-up, condensation, which is normal, forms on the inside of WKHJODVVDQGFDXVHVOLQWGXVWDQGRWKHUDLUERUQHSDUWLFOHVWR FOLQJWRWKHJODVVVXUIDFH$OVRLQLWLDOSDLQWFXULQJPD\GHSRVLW DVOLJKW¿OPRQWKHJODVV,WLVWKHUHIRUHUHFRPPHQGHGWKDW WKHJODVVEHFOHDQHGWZRRUWKUHHWLPHVZLWKDQRQDPPRQLD KRXVHKROG FOHDQHU DQG ZDUP ZDWHU ZH UHFRPPHQG JDV VWRYHJODVVFOHDQHU $IWHUWKDWWKHJODVVVKRXOGEHFOHDQHG WZRRUWKUHHWLPHVGXULQJHDFKKHDWLQJVHDVRQGHSHQGLQJ RQWKHFLUFXPVWDQFHVSUHVHQW 127(&OHDQJODVVDIWHU¿UVWWZRZHHNVRIRSHUDWLRQ ! WARNING $OORZWKHJODVVWRFRROFRPSOHWHO\EHIRUHDWWHPSWLQJWR FOHDQ DANGER &DUHIXOO\ LQVSHFW WKH /RJV IRU GDPDJH &RQWDFW \RXU ORFDOGHDOHULIDQ\GDPDJHLVHYLGHQW HOT GLASS WILL CAUSE BURNS. 8VHDVRIWEULVWOHGEUXVKWRVZHHSGXVWRUGHEULVIURPWKH /RJV3LORWDQG%XUQHU8VHFDUHDVWKHORJVDUHIUDJLOH DQGVXVFHSWLEOHWRGDPDJH DO NOT TOUCH GLASS UNTIL COOLED. 5HSODFHWKHJODVVSDQHODQGIUDPHDVVHPEO\ 5HSODFHWKHVWRYHIURQWDQGVDIHW\EDUULHU Care of Cast Iron $QRFFDVLRQDOGXVWLQJZLWKDGU\UDJZLOOKHOSNHHSWKHSDLQWHG VXUIDFHV ORRNLQJ QHZ 8VH KLJKWHPSHUDWXUH VWRYH SDLQWV DYDLODEOH WKURXJK \RXU ORFDO GHDOHU WR WRXFKXS DUHDV DV QHHGHG&OHDQDUHDVWREHSDLQWHGZLWKDZLUHEUXVKDQGEH VXUHWRFRYHUWKHORJVEXUQHUDQGYDOYHDVVHPEO\JODVVDQG IUDPHDVVHPEO\$SSO\WKHSDLQWVSDULQJO\WZROLJKWFRDWVRI SDLQWZLOOJLYHEHWWHUUHVXOWVWKDQDVLQJOHKHDY\FRDW NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed. &OHDQ SRUFHODLQ HQDPHO VXUIDFHV ZLWK D VRIW GDPS FORWK 'RQRWXVHDEUDVLYHFOHDQLQJDJHQWV,IQHFHVVDU\XVHRQO\ DFOHDQLQJDJHQWIRUPXODWHGHVSHFLDOO\IRUXVHRQSRUFHODLQ HQDPHOVXUIDFHV ! CAUTION 7XUQWKHSLORWRIIEHIRUHSDLQWLQJ$OORZWKHKHDWHUWRFRRO FRPSOHWHO\EHIRUHSDLQWLQJ 51 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Glass Replacement 5HSODFH JODVV RQO\ ZLWK ++7 DSSURYHG SDUWV 5HIHU WR 5HSODFHPHQW3DUWVVHFWLRQIRUFRUUHFWJODVV5HIHUWR)LJXUHV 87 and 88 and previous instructions for removal of the GDPDJHGJODVVIUDPH 6WDUWLQJRQDORQJHGJHUHPRYHDERXWRIWKHSURWHFWLYH SDSHUVWULSDQGDSSO\WKHÀDWDGKHVLYHIDFHRIWKHJDVNHW DURXQG WKH RXWVLGHIDFLQJ HGJH RI WKH SDQHO &RQWLQXH DURXQGWKHSDQHODSSO\LQJDERXWDWDWLPHDQGEHLQJ FDUHIXO WR QRW VWUHWFK WKH PDWHULDO 'R QRW RYHUODS WKH JDVNHWHQGV )LJXUH $SSO\ D WKLQ EHDG RI KLJK WHPSHUDWXUH VLOLFRQH UXEEHU VHDODQW DORQJ WKH LQVLGH FRUQHU RI WKH JODVV IUDPH DOO DURXQGWKHSHULPHWHU3ODFHWKHÀDWJDVNHWHGVLGHRIWKH JODVVSDQHOEDFNLQWRWKHVWHHOIUDPH3LQFKWKHURXQGHG LQVLGHIDFLQJJDVNHWPDWHULDOWREXONLWXS 5HSODFH WKH JODVV IUDPH DQG IURQW SDQHO DV SUHYLRXVO\ GHVFULEHG )LJXUH5HPRYHWKHVWRYHIURQW )LJXUH:UDSWKHJDVNHWPDWHULDODURXQGWKHRXWVLGHHGJHRIWKHJODVV Inspect the Vent System Annually +DYH WKH YHQW V\VWHP LQVSHFWHG DQQXDOO\ E\ D TXDOL¿HG WHFKQLFLDQ6KXWRIIWKHPDLQJDVVXSSO\EHIRUHLQVSHFWLQJ WKH V\VWHP %RWK WKH LQQHU H[KDXVW SLSH DQG WKH RXWHU FRPEXVWLRQ VXSSO\ SLSH PXVW EH FKHFNHG WR FRQ¿UP WKDW WKH\DUHXQEORFNHGDQGLQJRRGFRQGLWLRQ Check the Gas Flame Regularly 7R HQVXUH WKDW WKH VWRYH LV RSHUDWLQJ SURSHUO\ FKHFN WKH ÀDPHV SHULRGLFDOO\ WR FRQ¿UP WKH\ PDWFK )LJXUH 7KH ÀDPHVZLOOEHEOXHGXULQJWKH¿UVWPLQXWHVRIRSHUDWLRQ DQGZLOOJUDGXDOO\WXUQWR\HOORZDIWHUWKDW )LJXUH5HOHDVHWKHODWFKHVWRUHPRYHWKHJODVVIUDPH Gasket Replacement 7KH6WDUGDQFH*DVKHDWHUXVHVDµWDGSROH¶W\SHJDVNHWWR VHDO EHWZHHQ WKH JODVV SDQHO DQG WKH IUDPH ,Q WLPH WKLV JDVNHWFDQEHFRPHEULWWOHDQGFRPSUHVVHGDQGVKRXOGEH UHSODFHG1HZJDVNHWLVDYDLODEOHIURP\RXUGHDOHU 'RQRWXVH\RXUVWRYHLIWKHÀDPHSDWWHUQGLIIHUVIURPWKDW VKRZQ KHUH &RQWDFW \RXU 9HUPRQW &DVWLQJV GHDOHU RU D TXDOL¿HGWHFKQLFLDQIRUKHOS 6KXWRIIWKHJDVVXSSO\DQGDOORZWKHVWRYHWRFRRO:HDU VDIHW\JRJJOHVDQGDGXVWPDVN 5HPRYH WKH )URQW *ODVV )UDPH DQG *ODVV 3DQHO )LJXUHV 5HPRYHWKHROGJDVNHW8VHDUD]RU EODGHWRVHSDUDWHWKHJODVVDQGJDVNHWIURPWKHIUDPH DQGWRFOHDQWKHJODVVRIDQ\UHPDLQLQJFHPHQWRUELWVRI JDVNHW8VHDFROGFKLVHOLIQHFHVVDU\ 'HWHUPLQH WKH FRUUHFW OHQJWK RI JDVNHW E\ OD\LQJ LW RXW DURXQGWKHHGJHRIWKHJODVV$OORZDQH[WUD± PP 0DUNWKHVSRWWREHFXW8VHDXWLOLW\NQLIH 52 )LJXUH3URSHUÀDPHDSSHDUDQFH Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Wiring Diagrams – SDDVT Optional Blower Kit Wiring Diagram OFF On/Off Switch Wiring ON FAN TP/TH Thermopile Black POWER CORD BLK WHT BL TP K Black TH Chassis Ground Thermostat (Optional) BL K BLK FAN JUNCTION BOX Thermopile Black Optional Thermostat Wiring TP/TH GRN Strain Relief ON / OFF Rheostat TP TH Black Snapstat )LJXUH2QRIIVZLWFKDQGRSWLRQDOWKHUPRVWDWFLUFXLW WHT LK NOTE: If any of the original wire, as supplied with the appliance, must be replaced, it must be replaced with W\SH6)&ZLUHRULWVHTXLYDOHQW B BLK GRN Chassis Ground RHEOSTAT / SNAPSTAT BOX Optional Blower Kit Schematic Diagram BLK BLK MOTOR BLK WHT GRN WHT BLK SNAPSTAT ON/OFF RHEOSTAT )LJXUH)DQFLUFXLW 53 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Pilot A/C MODULE Opt. Blower Opt. Aux. WHITE BLACK BLACK WHITE PLUG-IN CONNECTOR TO JUNCTION BOX IN FIREPLACE RF Receiver ON/OFF Button GREEN 300 Watt Max. Control Board Black / Thermopile Red / Thermopile Sensor Conversion NG/LP Ignitor / Sparker Plug-in Connector Control Board to Command Center NOTE: Wall switch wires must be connected together if a wall switch is not being used. OFF/LO Plug-in Connector Stepper Motor to Control Board Ground LED ON/HI Master Switch Command Center Optional Wall Switch DC Power/Green Plug-in Connector Control Board to Solenoid Gas Out Gas In Pilot Gas Tubing Valve )LJXUH6LJQDWXUH&RPPDQG:LULQJ'LDJUDP To Junction Box In Fireplace Light { WHITE BLACK Optional AUX { WHITE BLACK BLACK WHITE GREEN Connector Pin To Control Box )LJXUH%ORZHU:LULQJ'LDJUDP 54 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Service Parts List STARDANCE Service Parts Beginning Manufacturing Date: NA Ending Manufacturing Date: Active Direct Vent Gas Heater Active Skus Retired Skus SDVTSCCB (Classic Black) SDDVTCBSB (Classic Black) SDDVTCSCBSB (Classic Black) - End Manufacturing Date: October 2015 SDVTSCBS (Biscuit) SDDVTBSSB (Biscuit) SDDVTCSBSSB (Biscuit) - End Manufacturing Date: October 2015 SDVTSCBM (Majolica Brown) SDDVTBMSB (Majolica Brown) SDDVTCSBMSB (Majolica Brown) - End Manufacturing Date: October 2015 SDVTSCBD (Bordeaux) SDDVTBDSB (Bordeaux) SDDVTCSBDSB (Bordeaux) - End Manufacturing Date: October 2015 2 1 6 5 1.1 4 1.3 1.4 3 1.2 14 11 12 10 8 7 15 16 13 9 17 18 24 25 36 31 27 26 33 35 28 30 34 32 41 37 29 20 21 19 22 40 39 38 42 23 Part number list on following page. 55 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 11/18 3-90-20306760 STARDANCE Service Parts Beginning Manufacturing Date: NA Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. ITEM DESCRIPTION COMMENTS Stocked at Depot PART NUMBER Log Set, Complete 20012551 1.1 Log, Rear 20012546 1.2 Log, Right 20012548 1.3 Log, Left 20012547 1.4 Log, Top 20012915 Ember Bed Assembly 20012492 1 2 3 4 5 6 7 8 Top Front, Operable Door Door, Right (Use Magnet) (Pre 7/2007 units must order Left and Rigth together) Door, Left (Use Magnet) (Pre 7/2007 units must order Left and Rigth together) End, Left End, Right Classic Black 30001276A Biscuit 30003305 Bordeaux 30006752 Brown Majolica 30004897 Classic Black 30001496A Biscuit 30003302 Bordeaux 30006753 Brown Majolica 30004899 Classic Black 30004081A Biscuit 30004089 Bordeaux 30006754 Brown Majolica 30004901 Classic Black 30004082A Biscuit 30004090 Bordeaux 30006755 Brown Majolica 30004900 Classic Black 30001280A Biscuit 30003300 Bordeaux 30006750 Brown Majolica 30004895 Classic Black 30001279A Biscuit 30003301 Bordeaux 30006751 Brown Majolica 30004896 Y Y 9 Door, Control 1301087A 10 Glass Frame Assembly 30000127 Y 11 Glass 1601691 Y 12 Gasket, Glass (Medium Knit) 1203702K 13 Nut, Hex Jam 3/8-16 TOPLK-Z 14 Pawl Assembly, Ash Door 30002362 15 Front Steel Handle/Shaft - NI/VER 30002717 Pkg of 10 1203290-10 Y Additional service parts on following page 56 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 STARDANCE Service Parts Beginning Manufacturing Date: NA Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. ITEM DESCRIPTION 16 Restrictor Plate 17 Fan Blower 18 Valve, Nova SIT 820.852 RN 19 Pilot Assembly 3 Way (SDDVT) COMMENTS Stocked at Depot PART NUMBER 20013026 SDVTSC Series Only 20308374 SDDVT Series Only FK26 SDDVT Series Only 20012218 Y N/DV RN 0.199.706 SRV10002264 Y N/DV RP 0.199.703 SRV10002265 Y Y 20 Thermocouple, 24” SRV24D0808 21 Electrode Ignitor w/Cable SIT24 10001297 22 Thermopile, 18” RS SRV26D0566 Y 23 Tubing Pilot w/Fittings 1/8 x 24” 26D0665 Y 24 Pilot Ori¿ce, Top Convertible 25 Ori¿ce Hood 26 Ignitor Piezo w/Nut SIT Bracket, Piezo Ignitor Control 27 Manifold Assembly 28 Air Shutter Assembly 29 30 SDDVT NG, #62 37D0022 SDDVT LP, #35 SRV200-2630 NG, 2.4 mm 4604-316 LP, 1.45 mm 20308650 SDDVT Series Only SDVTSC Series Only 057958A Y Y 20300111K 20012553 Y 20012517 Trim On/Off Switch SDDVT Series Only 30000874 Y Sensor1450 CMG-8184-0032 Only for FSDHAG 10002013 Y 31 Wiring Harness SDDVT Series Only 10002582 Y 32 Gasket, Base Pan 20002282 Y 33 Gasket HE Door 1203687A Y 34 Tie Bracket Assembly 20012514 35 Safety Screen Barrier 30007254 36 Right Burner Support Assembly 20012512 37 Remote Transmitter (Full function) SDVTSC Series Only TSFSC 38 Command Center SDVTSC Series Only SRV80D0005 Y 39 Gas Valve Assembly, SDVTSC Series Only NG SRV80D0001 Y 40 Control Box, SDVTSC Series Only Y LP SRV80D0002 Y NG SRV80D0018 Y LP SRV80D0019 Y 41 AC Module SCS w/8’ Power Cord SDVTSC Series Only 3007360 42 Pilot Assembly SDVTSC Series Only 20308981 Y 30004175K Y Handle Package w/Screw Switch Bracket Wood 53821K Additional service parts on following page 57 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 STARDANCE Service Parts Beginning Manufacturing Date: NA Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. ITEM DESCRIPTION COMMENTS Starter Pipe Stocked at Depot PART NUMBER 20307738K Rear Shroud SDVT, SC/SDDVT Rear Shroud Assembly SDDVTCS Fiberglass Gasket, 1/4” 20003802 20300122 1-00-1203560 Use super glue/Silicone to attach Magnet, Door Touch-Up Paint Y 30004112 Classic Black 3-42-19905 Bordeaux 0001341 Biscuit 0001277 Majolica 0001270 Wire Valve/Control SDVTSC Series Only SRV80D0010 Wire AC Module SDVTSC Series Only SRV80D0009 Wire Command Center SDVTSC Series Only 80D0008 Cover, Vanity Control 20308405K Control Plate Assembly (Burner, Valve, Pilot, Comm. Center) 20308376K Control Plate Assembly (Burner, Valve, Pilot) 20012493 Y Y Conversion Kits Conversion Kit, NG to LP Conversion Kit, LP to NG Conversion Kit, NG to LP Conversion Kit, LP to NG 58 SDDVT SDVTSC 20012735K Y 4604-012 Y 4604-011 Y 4604-013 Y Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Optional Accessories FK26 Fan Kits – SDDVT Series 7KH).IDQKHOSVGLVWULEXWHKHDWHGDLUIURPZLWKLQWKH¿UHER[ RXWLQWRWKHURRP7KHIDQLVFRQWUROOHGE\DVQDSVWDWWKDW WXUQVSRZHURQDQGRIIDVWKH¿UHER[WHPSHUDWXUHULVHVDERYH DQGIDOOVEHORZDSUHVHWWHPSHUDWXUH$UKHRVWDWSURYLGHVIRU YDULDEOHIDQVSHHGV8VHGZLWKVWDQGDUGPLOOLYROWPRGHOV 6SHFL¿FDWLRQV 9ROW+]$PSV Maintenance 7KHIDQLWVHOIGRHVQRWUHTXLUHUHJXODUPDLQWHQDQFHKRZHYHU SHULRGLF FOHDQLQJ RI WKH IDQ DQG WKH VXUURXQGLQJ DUHD LV UHTXLUHG Remote Controls – SDDVT The remote control allows you to turn the heater on or off IURP DQ\ZKHUH LQ WKH URRP 5HIHU WR 3DJH IRU ZLULQJ GLDJUDPV7KHVHUHPRWHFRQWUROVDUHIRUXVHZLWKVWDQGDUG PLOOLYROWPRGHOV ON/OFF Remotes RCB,RCMT 59 Warming Shelf :DUPLQJVKHOYHVDGGYHUVDWLOLW\WR\RXUVWRYHWKH\FDQEH XVHGWRNHHSIRRGVZDUPDWPHDOWLPH Model 2702 2684 Color Classic Black %URZQ0DMROLFD Biscuit %RUGHDX[ Shelf Installation $WWDFKWKHVKHOIORRVHO\WRWKHVWRYHOHDYLQJWKHVFUHZV ORRVHHQRXJKWRDOORZ¿QDODGMXVWPHQWV 3RVLWLRQWKHVKHOIDQGDGMXVWWKHEUDFNHWVVRWKHVKHOI¿WV FRUUHFWO\ 7LJKWHQWKHVFUHZV 5HIHUWRWKHLQVWUXFWLRQVLQFOXGHGZLWKHDFKZDUPLQJVKHOI IRUFRPSOHWHLQVWDOODWLRQSURFHGXUHV ON/OFF Thermostat Remote TSST, RCST Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 Hearth & Home Technologies LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (“HHT”), extends the following warranty for HHT gas, wood, pellet and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: ,,dǁĂƌƌĂŶƚƐƚŽƚŚĞŽƌŝŐŝŶĂůŽǁŶĞƌŽĨƚŚĞ,,dĂƉƉůŝĂŶĐĞĂƚƚŚĞƐŝƚĞŽĨŝŶƐƚĂůůĂƟŽŶ͕ĂŶĚƚŽĂŶLJƚƌĂŶƐĨĞƌĞĞƚĂŬŝŶŐŽǁŶĞƌƐŚŝƉŽĨƚŚĞ ĂƉƉůŝĂŶĐĞĂƚƚŚĞƐŝƚĞŽĨŝŶƐƚĂůůĂƟŽŶǁŝƚŚŝŶƚǁŽLJĞĂƌƐĨŽůůŽǁŝŶŐƚŚĞĚĂƚĞŽĨŽƌŝŐŝŶĂůƉƵƌĐŚĂƐĞ͕ƚŚĂƚƚŚĞ,,dĂƉƉůŝĂŶĐĞǁŝůůďĞĨƌĞĞĨƌŽŵ ĚĞĨĞĐƚƐŝŶŵĂƚĞƌŝĂůƐĂŶĚǁŽƌŬŵĂŶƐŚŝƉĂƚƚŚĞƟŵĞŽĨŵĂŶƵĨĂĐƚƵƌĞ͘ŌĞƌŝŶƐƚĂůůĂƟŽŶ͕ŝĨĐŽǀĞƌĞĚĐŽŵƉŽŶĞŶƚƐŵĂŶƵĨĂĐƚƵƌĞĚďLJ,,d ĂƌĞĨŽƵŶĚƚŽďĞĚĞĨĞĐƟǀĞŝŶŵĂƚĞƌŝĂůƐŽƌǁŽƌŬŵĂŶƐŚŝƉĚƵƌŝŶŐƚŚĞĂƉƉůŝĐĂďůĞǁĂƌƌĂŶƚLJƉĞƌŝŽĚ͕,,dǁŝůů͕ĂƚŝƚƐŽƉƟŽŶ͕ƌĞƉĂŝƌŽƌƌĞƉůĂĐĞ ƚŚĞĐŽǀĞƌĞĚĐŽŵƉŽŶĞŶƚƐ͘,,d͕ĂƚŝƚƐŽǁŶĚŝƐĐƌĞƟŽŶ͕ŵĂLJĨƵůůLJĚŝƐĐŚĂƌŐĞĂůůŽĨŝƚƐŽďůŝŐĂƟŽŶƐƵŶĚĞƌƐƵĐŚǁĂƌƌĂŶƟĞƐďLJƌĞƉůĂĐŝŶŐƚŚĞ ƉƌŽĚƵĐƚŝƚƐĞůĨŽƌƌĞĨƵŶĚŝŶŐƚŚĞǀĞƌŝĮĞĚƉƵƌĐŚĂƐĞƉƌŝĐĞŽĨƚŚĞƉƌŽĚƵĐƚŝƚƐĞůĨ͘dŚĞŵĂdžŝŵƵŵĂŵŽƵŶƚƌĞĐŽǀĞƌĂďůĞƵŶĚĞƌƚŚŝƐǁĂƌƌĂŶƚLJ ŝƐůŝŵŝƚĞĚƚŽƚŚĞƉƵƌĐŚĂƐĞƉƌŝĐĞŽĨƚŚĞƉƌŽĚƵĐƚ͘dŚŝƐǁĂƌƌĂŶƚLJŝƐƐƵďũĞĐƚƚŽĐŽŶĚŝƟŽŶƐ͕ĞdžĐůƵƐŝŽŶƐĂŶĚůŝŵŝƚĂƟŽŶƐĂƐĚĞƐĐƌŝďĞĚďĞůŽǁ͘ WARRANTY PERIOD: tĂƌƌĂŶƚLJĐŽǀĞƌĂŐĞĨŽƌĐŽŶƐƵŵĞƌƐďĞŐŝŶƐĂƚƚŚĞĚĂƚĞŽĨŝŶƐƚĂůůĂƟŽŶ͘/ŶƚŚĞĐĂƐĞŽĨŶĞǁŚŽŵĞĐŽŶƐƚƌƵĐƟŽŶ͕ǁĂƌƌĂŶƚLJĐŽǀĞƌĂŐĞďĞŐŝŶƐ ŽŶƚŚĞĚĂƚĞŽĨĮƌƐƚŽĐĐƵƉĂŶĐLJŽĨƚŚĞĚǁĞůůŝŶŐŽƌƐŝdžŵŽŶƚŚƐĂŌĞƌƚŚĞƐĂůĞŽĨƚŚĞƉƌŽĚƵĐƚďLJĂŶŝŶĚĞƉĞŶĚĞŶƚ͕ĂƵƚŚŽƌŝnjĞĚ,,dĚĞĂůĞƌͬ ĚŝƐƚƌŝďƵƚŽƌ͕ǁŚŝĐŚĞǀĞƌŽĐĐƵƌƐĞĂƌůŝĞƌ͘,ŽǁĞǀĞƌ͕ƚŚĞǁĂƌƌĂŶƚLJƐŚĂůůĐŽŵŵĞŶĐĞŶŽůĂƚĞƌƚŚĂŶϮϰŵŽŶƚŚƐĨŽůůŽǁŝŶŐƚŚĞĚĂƚĞŽĨƉƌŽĚƵĐƚ ƐŚŝƉŵĞŶƚĨƌŽŵ,,d͕ƌĞŐĂƌĚůĞƐƐŽĨƚŚĞŝŶƐƚĂůůĂƟŽŶŽƌŽĐĐƵƉĂŶĐLJĚĂƚĞ͘dŚĞǁĂƌƌĂŶƚLJƉĞƌŝŽĚĨŽƌƉĂƌƚƐĂŶĚůĂďŽƌĨŽƌĐŽǀĞƌĞĚĐŽŵƉŽŶĞŶƚƐ is produced in the following table. dŚĞƚĞƌŵ͞>ŝŵŝƚĞĚ>ŝĨĞƟŵĞ͟ŝŶƚŚĞƚĂďůĞďĞůŽǁŝƐĚĞĮŶĞĚĂƐ͗ϮϬLJĞĂƌƐĨƌŽŵƚŚĞďĞŐŝŶŶŝŶŐĚĂƚĞŽĨǁĂƌƌĂŶƚLJĐŽǀĞƌĂŐĞĨŽƌŐĂƐĂƉƉůŝĂŶĐĞƐ͕ ĂŶĚϭϬLJĞĂƌƐĨƌŽŵƚŚĞďĞŐŝŶŶŝŶŐĚĂƚĞŽĨǁĂƌƌĂŶƚLJĐŽǀĞƌĂŐĞĨŽƌǁŽŽĚĂŶĚƉĞůůĞƚĂƉƉůŝĂŶĐĞƐ͘dŚĞƐĞƟŵĞƉĞƌŝŽĚƐƌĞŇĞĐƚƚŚĞŵŝŶŝŵƵŵ ĞdžƉĞĐƚĞĚƵƐĞĨƵůůŝǀĞƐŽĨƚŚĞĚĞƐŝŐŶĂƚĞĚĐŽŵƉŽŶĞŶƚƐƵŶĚĞƌŶŽƌŵĂůŽƉĞƌĂƟŶŐĐŽŶĚŝƟŽŶƐ͘ Warranty Period Parts Labor 1 Year 2 years HHT Manufactured Appliances and Venting Gas Pellet Wood Electric Venting Components Covered X X X X x All parts and material except as covered by Conditions, Exclusions, and Limitations listed X X Igniters, auger motors, electronic components, and glass X X Factory-installed blowers X Molded refractory panels X Ignition Modules X 3 years Firepots, burnpots, mechanical feeders/auger assemblies X Vent Free burners, Vent Free ceramic fiber logs, Aluminized Burners X 5 years 1 year X X Castings and Baffles X Catalyst - limitations listed X Manifold tubes, HHT chimney and termination 6 years 3 years 7 years 3 years 10 years 1 year X Limited Lifetime 3 years X X X X X X 90 Days X Burners, logs and refractory Firebox and heat exchanger, Grate and Stainless Steel Burners, FlexBurnΠ System (engine, inner cover,access cover and fireback) X X All replacement parts beyond warranty period WARRANTY CONDITIONS: ͻ dŚŝƐ ǁĂƌƌĂŶƚLJ ŽŶůLJ ĐŽǀĞƌƐ ,,d ĂƉƉůŝĂŶĐĞƐ ƚŚĂƚ ĂƌĞ ƉƵƌĐŚĂƐĞĚ ƚŚƌŽƵŐŚ ĂŶ ,,d ĂƵƚŚŽƌŝnjĞĚ ĚĞĂůĞƌ Žƌ ĚŝƐƚƌŝďƵƚŽƌ͘ ůŝƐƚ ŽĨ ,,d ĂƵƚŚŽƌŝnjĞĚĚĞĂůĞƌƐŝƐĂǀĂŝůĂďůĞŽŶƚŚĞ,,dďƌĂŶĚĞĚǁĞďƐŝƚĞƐ͘ ͻ dŚŝƐǁĂƌƌĂŶƚLJŝƐŽŶůLJǀĂůŝĚǁŚŝůĞƚŚĞ,,dĂƉƉůŝĂŶĐĞƌĞŵĂŝŶƐĂƚƚŚĞƐŝƚĞŽĨŽƌŝŐŝŶĂůŝŶƐƚĂůůĂƟŽŶ͘ ͻ dŚŝƐǁĂƌƌĂŶƚLJŝƐŽŶůLJǀĂůŝĚŝŶƚŚĞĐŽƵŶƚƌLJŝŶǁŚŝĐŚƚŚĞ,,dĂƵƚŚŽƌŝnjĞĚĚĞĂůĞƌŽƌĚŝƐƚƌŝďƵƚŽƌƚŚĂƚƐŽůĚƚŚĞĂƉƉůŝĂŶĐĞƌĞƐŝĚĞƐ͘ ͻ ŽŶƚĂĐƚLJŽƵƌŝŶƐƚĂůůŝŶŐĚĞĂůĞƌĨŽƌǁĂƌƌĂŶƚLJƐĞƌǀŝĐĞ͘/ĨƚŚĞŝŶƐƚĂůůŝŶŐĚĞĂůĞƌŽƌĚŝƐƚƌŝďƵƚŽƌŝƐƵŶĂďůĞƚŽƉƌŽǀŝĚĞŶĞĐĞƐƐĂƌLJƉĂƌƚƐ͕ĐŽŶƚĂĐƚ ƚŚĞŶĞĂƌĞƐƚ,,dĂƵƚŚŽƌŝnjĞĚĚĞĂůĞƌŽƌƐƵƉƉůŝĞƌ͘ĚĚŝƟŽŶĂůƐĞƌǀŝĐĞĨĞĞƐŵĂLJĂƉƉůLJŝĨLJŽƵĂƌĞƐĞĞŬŝŶŐǁĂƌƌĂŶƚLJƐĞƌǀŝĐĞĨƌŽŵĂĚĞĂůĞƌ other than the dealer from whom you originally purchased the product. ͻ ŚĞĐŬǁŝƚŚLJŽƵƌĚĞĂůĞƌŝŶĂĚǀĂŶĐĞĨŽƌĂŶLJĐŽƐƚƐƚŽLJŽƵǁŚĞŶĂƌƌĂŶŐŝŶŐĂǁĂƌƌĂŶƚLJĐĂůů͘dƌĂǀĞůĂŶĚƐŚŝƉƉŝŶŐĐŚĂƌŐĞƐĨŽƌƉĂƌƚƐĂƌĞŶŽƚ ĐŽǀĞƌĞĚďLJƚŚŝƐǁĂƌƌĂŶƚLJ͘ • Limited Catalyst Warranty Ž &ŽƌǁŽŽĚďƵƌŶŝŶŐƉƌŽĚƵĐƚƐĐŽŶƚĂŝŶŝŶŐĂĐĂƚĂůLJƐƚ͕ƚŚĞĐĂƚĂůLJƐƚǁŝůůďĞǁĂƌƌĂŶƚĞĚĨŽƌĂƐŝdžͲLJĞĂƌƉĞƌŝŽĚĂƐĨŽůůŽǁƐ͗ŝĨƚŚĞŽƌŝŐŝŶĂů ĐĂƚĂůLJƐƚŽƌĂƌĞƉůĂĐĞŵĞŶƚĐĂƚĂůLJƐƚƉƌŽǀĞƐĚĞĨĞĐƟǀĞŽƌĐĞĂƐĞƐƚŽŵĂŝŶƚĂŝŶϳϬйŽĨŝƚƐƉĂƌƟĐƵůĂƚĞĞŵŝƐƐŝŽŶƌĞĚƵĐƟŽŶĂĐƟǀŝƚLJ;ĂƐ ŵĞĂƐƵƌĞĚďLJĂŶĂƉƉƌŽǀĞĚƚĞƐƟŶŐƉƌŽĐĞĚƵƌĞͿǁŝƚŚŝŶϯϲŵŽŶƚŚƐĨƌŽŵƚŚĞƉƵƌĐŚĂƐĞĚĂƚĞ͕ƚŚĞĐĂƚĂůLJƐƚǁŝůůďĞƌĞƉůĂĐĞĚĨŽƌĨƌĞĞ͘ Ž &ƌŽŵϯϳƚŽϳϮŵŽŶƚŚƐĂƉƌŽͲƌĂƚĞĚĐƌĞĚŝƚǁŝůůďĞĂůůŽǁĞĚĂŐĂŝŶƐƚĂƌĞƉůĂĐĞŵĞŶƚĐĂƚĂůLJƐƚĂŶĚůĂďŽƌĐƌĞĚŝƚŶĞĐĞƐƐĂƌLJƚŽŝŶƐƚĂůů ƚŚĞƌĞƉůĂĐĞŵĞŶƚĐĂƚĂůLJƐƚ͘dŚĞƉƌŽƌĂƟŽŶƌĂƚĞŝƐĂƐĨŽůůŽǁƐ͗ Amount of Time Since Purchase ϬͲϯϲDŽŶƚŚƐ ϯϳͲϰϴDŽŶƚŚƐ ϰϵͲϲϬDŽŶƚŚƐ ϲϭͲϳϮDŽŶƚŚƐ Credit Towards Replacement Cost ϭϬϬй ϯϬй ϮϬй ϭϬй Ž ŶLJƌĞƉůĂĐĞŵĞŶƚĐĂƚĂůLJƐƚǁŝůůďĞǁĂƌƌĂŶƚĞĚƵŶĚĞƌƚŚĞƚĞƌŵƐŽĨƚŚĞĐĂƚĂůLJƐƚǁĂƌƌĂŶƚLJĨŽƌƚŚĞƌĞŵĂŝŶŝŶŐƚĞƌŵŽĨƚŚĞŽƌŝŐŝŶĂů ǁĂƌƌĂŶƚLJ͘ dŚĞ ƉƵƌĐŚĂƐĞƌ ŵƵƐƚ ƉƌŽǀŝĚĞ ƚŚĞ ŶĂŵĞ͕ ĂĚĚƌĞƐƐ͕ ĂŶĚ ƚĞůĞƉŚŽŶĞ ŶƵŵďĞƌ ŽĨ ƚŚĞ ůŽĐĂƟŽŶ ǁŚĞƌĞ ƚŚĞ ƉƌŽĚƵĐƚ ŝƐ ŝŶƐƚĂůůĞĚ͕ƉƌŽŽĨŽĨŽƌŝŐŝŶĂůƉƵƌĐŚĂƐĞĚĂƚĞ͕ĚĂƚĞŽĨĨĂŝůƵƌĞ͕ĂŶĚĂŶLJƌĞůĞǀĂŶƚŝŶĨŽƌŵĂƟŽŶƌĞŐĂƌĚŝŶŐƚŚĞĨĂŝůƵƌĞŽĨƚŚĞĐĂƚĂůLJƐƚ͘ WARRANTY EXCLUSIONS: dŚŝƐǁĂƌƌĂŶƚLJĚŽĞƐŶŽƚĐŽǀĞƌƚŚĞĨŽůůŽǁŝŶŐ͗ ͻ ŚĂŶŐĞƐŝŶƐƵƌĨĂĐĞĮŶŝƐŚĞƐĂƐĂƌĞƐƵůƚŽĨŶŽƌŵĂůƵƐĞ͘ƐĂŚĞĂƟŶŐĂƉƉůŝĂŶĐĞ͕ƐŽŵĞĐŚĂŶŐĞƐŝŶĐŽůŽƌŽĨŝŶƚĞƌŝŽƌĂŶĚĞdžƚĞƌŝŽƌƐƵƌĨĂĐĞ ĮŶŝƐŚĞƐŵĂLJŽĐĐƵƌ͘dŚŝƐŝƐŶŽƚĂŇĂǁĂŶĚŝƐŶŽƚĐŽǀĞƌĞĚƵŶĚĞƌǁĂƌƌĂŶƚLJ͘ ͻ ĂŵĂŐĞ ƚŽ ƉƌŝŶƚĞĚ͕ ƉůĂƚĞĚ͕ Žƌ ĞŶĂŵĞůĞĚ ƐƵƌĨĂĐĞƐ ĐĂƵƐĞĚ ďLJ ĮŶŐĞƌƉƌŝŶƚƐ͕ ĂĐĐŝĚĞŶƚƐ͕ ŵŝƐƵƐĞ͕ ƐĐƌĂƚĐŚĞƐ͕ ŵĞůƚĞĚ ŝƚĞŵƐ͕ Žƌ ŽƚŚĞƌ ĞdžƚĞƌŶĂůƐŽƵƌĐĞƐĂŶĚƌĞƐŝĚƵĞƐůĞŌŽŶƚŚĞƉůĂƚĞĚƐƵƌĨĂĐĞƐĨƌŽŵƚŚĞƵƐĞŽĨĂďƌĂƐŝǀĞĐůĞĂŶĞƌƐŽƌƉŽůŝƐŚĞƐ͘ ͻ ZĞƉĂŝƌŽƌƌĞƉůĂĐĞŵĞŶƚŽĨƉĂƌƚƐƚŚĂƚĂƌĞƐƵďũĞĐƚƚŽŶŽƌŵĂůǁĞĂƌĂŶĚƚĞĂƌĚƵƌŝŶŐƚŚĞǁĂƌƌĂŶƚLJƉĞƌŝŽĚĂƌĞŶŽƚĐŽǀĞƌĞĚ͘dŚĞƐĞƉĂƌƚƐ ŝŶĐůƵĚĞ͗ƉĂŝŶƚ͕ǁŽŽĚĂŶĚƉĞůůĞƚŐĂƐŬĞƚƐ͕ĮƌĞďƌŝĐŬƐ͕ŐƌĂƚĞƐ͕ŇĂŵĞŐƵŝĚĞƐ͕ďĂƩĞƌŝĞƐĂŶĚƚŚĞĚŝƐĐŽůŽƌĂƟŽŶŽĨŐůĂƐƐ͘ ͻ DŝŶŽƌĞdžƉĂŶƐŝŽŶ͕ĐŽŶƚƌĂĐƟŽŶ͕ŽƌŵŽǀĞŵĞŶƚŽĨĐĞƌƚĂŝŶƉĂƌƚƐĐĂƵƐŝŶŐŶŽŝƐĞ͘dŚĞƐĞĐŽŶĚŝƟŽŶƐĂƌĞŶŽƌŵĂůĂŶĚĐŽŵƉůĂŝŶƚƐƌĞůĂƚĞĚƚŽ ƚŚŝƐŶŽŝƐĞĂƌĞŶŽƚĐŽǀĞƌĞĚďLJƚŚŝƐǁĂƌƌĂŶƚLJ͘ ͻ ĂŵĂŐĞƐƌĞƐƵůƟŶŐĨƌŽŵ͗;ϭͿĨĂŝůƵƌĞƚŽŝŶƐƚĂůů͕ŽƉĞƌĂƚĞ͕ŽƌŵĂŝŶƚĂŝŶƚŚĞĂƉƉůŝĂŶĐĞŝŶĂĐĐŽƌĚĂŶĐĞǁŝƚŚƚŚĞŝŶƐƚĂůůĂƟŽŶŝŶƐƚƌƵĐƟŽŶƐ͕ ŽƉĞƌĂƟŶŐ ŝŶƐƚƌƵĐƟŽŶƐ͕ ĂŶĚ ůŝƐƟŶŐ ĂŐĞŶƚ ŝĚĞŶƟĮĐĂƟŽŶ ůĂďĞů ĨƵƌŶŝƐŚĞĚ ǁŝƚŚ ƚŚĞ ĂƉƉůŝĂŶĐĞ͖ ;ϮͿ ĨĂŝůƵƌĞ ƚŽ ŝŶƐƚĂůů ƚŚĞ ĂƉƉůŝĂŶĐĞ ŝŶ ĂĐĐŽƌĚĂŶĐĞǁŝƚŚůŽĐĂůďƵŝůĚŝŶŐĐŽĚĞƐ͖;ϯͿƐŚŝƉƉŝŶŐŽƌŝŵƉƌŽƉĞƌŚĂŶĚůŝŶŐ͖;ϰͿŝŵƉƌŽƉĞƌŽƉĞƌĂƟŽŶ͕ĂďƵƐĞ͕ŵŝƐƵƐĞ͕ĐŽŶƟŶƵĞĚŽƉĞƌĂƟŽŶ ǁŝƚŚĚĂŵĂŐĞĚ͕ĐŽƌƌŽĚĞĚŽƌĨĂŝůĞĚĐŽŵƉŽŶĞŶƚƐ͕ĂĐĐŝĚĞŶƚ͕ŽƌŝŵƉƌŽƉĞƌůLJͬŝŶĐŽƌƌĞĐƚůLJƉĞƌĨŽƌŵĞĚƌĞƉĂŝƌƐ;ϱͿĞŶǀŝƌŽŶŵĞŶƚĂůĐŽŶĚŝƟŽŶƐ͕ ŝŶĂĚĞƋƵĂƚĞǀĞŶƟůĂƟŽŶ͕ŶĞŐĂƟǀĞƉƌĞƐƐƵƌĞ͕ŽƌĚƌĂŌŝŶŐĐĂƵƐĞĚďLJƟŐŚƚůLJƐĞĂůĞĚĐŽŶƐƚƌƵĐƟŽŶƐ͕ŝŶƐƵĸĐŝĞŶƚŵĂŬĞͲƵƉĂŝƌƐƵƉƉůLJ͕Žƌ ŚĂŶĚůŝŶŐĚĞǀŝĐĞƐƐƵĐŚĂƐĞdžŚĂƵƐƚĨĂŶƐŽƌĨŽƌĐĞĚĂŝƌĨƵƌŶĂĐĞƐŽƌŽƚŚĞƌƐƵĐŚĐĂƵƐĞƐ͖;ϲͿƵƐĞŽĨĨƵĞůƐŽƚŚĞƌƚŚĂŶƚŚŽƐĞƐƉĞĐŝĮĞĚŝŶ ƚŚĞŽƉĞƌĂƟŽŶŝŶƐƚƌƵĐƟŽŶƐ͖;ϳͿŝŶƐƚĂůůĂƟŽŶŽƌƵƐĞŽĨĐŽŵƉŽŶĞŶƚƐŶŽƚƐƵƉƉůŝĞĚǁŝƚŚƚŚĞĂƉƉůŝĂŶĐĞŽƌĂŶLJŽƚŚĞƌĐŽŵƉŽŶĞŶƚƐŶŽƚ ĞdžƉƌĞƐƐůLJĂƵƚŚŽƌŝnjĞĚĂŶĚĂƉƉƌŽǀĞĚďLJ,,d͖;ϴͿŵŽĚŝĮĐĂƟŽŶŽĨƚŚĞĂƉƉůŝĂŶĐĞŶŽƚĞdžƉƌĞƐƐůLJĂƵƚŚŽƌŝnjĞĚĂŶĚĂƉƉƌŽǀĞĚďLJ,,dŝŶ ǁƌŝƟŶŐ͖ĂŶĚͬŽƌ;ϵͿŝŶƚĞƌƌƵƉƟŽŶƐŽƌŇƵĐƚƵĂƟŽŶƐŽĨĞůĞĐƚƌŝĐĂůƉŽǁĞƌƐƵƉƉůLJƚŽƚŚĞĂƉƉůŝĂŶĐĞ͘ ͻ EŽŶͲ,,dǀĞŶƟŶŐĐŽŵƉŽŶĞŶƚƐ͕ŚĞĂƌƚŚĐŽŶŶĞĐƟŽŶƐŽƌŽƚŚĞƌĂĐĐĞƐƐŽƌŝĞƐƵƐĞĚŝŶĐŽŶũƵŶĐƟŽŶǁŝƚŚƚŚĞĂƉƉůŝĂŶĐĞ͘ ͻ ŶLJƉĂƌƚŽĨĂƉƌĞͲĞdžŝƐƟŶŐĮƌĞƉůĂĐĞƐLJƐƚĞŵŝŶǁŚŝĐŚĂŶŝŶƐĞƌƚŽƌĂĚĞĐŽƌĂƟǀĞŐĂƐĂƉƉůŝĂŶĐĞŝƐŝŶƐƚĂůůĞĚ͘ ͻ ,,d͛ƐŽďůŝŐĂƟŽŶƵŶĚĞƌƚŚŝƐǁĂƌƌĂŶƚLJĚŽĞƐŶŽƚĞdžƚĞŶĚƚŽƚŚĞĂƉƉůŝĂŶĐĞ͛ƐĐĂƉĂďŝůŝƚLJƚŽŚĞĂƚƚŚĞĚĞƐŝƌĞĚƐƉĂĐĞ͘/ŶĨŽƌŵĂƟŽŶŝƐƉƌŽǀŝĚĞĚ ƚŽĂƐƐŝƐƚƚŚĞĐŽŶƐƵŵĞƌĂŶĚƚŚĞĚĞĂůĞƌŝŶƐĞůĞĐƟŶŐƚŚĞƉƌŽƉĞƌĂƉƉůŝĂŶĐĞĨŽƌƚŚĞĂƉƉůŝĐĂƟŽŶ͘ŽŶƐŝĚĞƌĂƟŽŶŵƵƐƚďĞŐŝǀĞŶƚŽƚŚĞ ĂƉƉůŝĂŶĐĞůŽĐĂƟŽŶĂŶĚĐŽŶĮŐƵƌĂƟŽŶ͕ĞŶǀŝƌŽŶŵĞŶƚĂůĐŽŶĚŝƟŽŶƐ͕ŝŶƐƵůĂƟŽŶĂŶĚĂŝƌƟŐŚƚŶĞƐƐŽĨƚŚĞƐƚƌƵĐƚƵƌĞ͘ This warranty is void if: ͻ dŚĞ ĂƉƉůŝĂŶĐĞ ŚĂƐ ďĞĞŶ ŽǀĞƌͲĮƌĞĚ͕ ŽƉĞƌĂƚĞĚ ŝŶ ĂƚŵŽƐƉŚĞƌĞƐ ĐŽŶƚĂŵŝŶĂƚĞĚ ďLJ ĐŚůŽƌŝŶĞ͕ ŇƵŽƌŝŶĞ͕ Žƌ ŽƚŚĞƌ ĚĂŵĂŐŝŶŐ ĐŚĞŵŝĐĂůƐ͘ KǀĞƌͲĮƌŝŶŐĐĂŶďĞŝĚĞŶƟĮĞĚďLJ͕ďƵƚŶŽƚůŝŵŝƚĞĚƚŽ͕ǁĂƌƉĞĚƉůĂƚĞƐŽƌƚƵďĞƐ͕ĚĞĨŽƌŵĂƟŽŶͬǁĂƌƉŝŶŐŽĨŝŶƚĞƌŝŽƌĐĂƐƚŝƌŽŶƐƚƌƵĐƚƵƌĞŽƌ ĐŽŵƉŽŶĞŶƚƐ͕ƌƵƐƚĐŽůŽƌĞĚĐĂƐƚŝƌŽŶ͕ďƵďďůŝŶŐ͕ĐƌĂĐŬŝŶŐĂŶĚĚŝƐĐŽůŽƌĂƟŽŶŽĨƐƚĞĞůŽƌĞŶĂŵĞůĮŶŝƐŚĞƐ͘ ͻ dŚĞĂƉƉůŝĂŶĐĞŝƐƐƵďũĞĐƚĞĚƚŽƉƌŽůŽŶŐĞĚƉĞƌŝŽĚƐŽĨĚĂŵƉŶĞƐƐŽƌĐŽŶĚĞŶƐĂƟŽŶ͘ • There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited ƚŽ͕ŝŵƉƌŽƉĞƌĐŚŝŵŶĞLJŽƌǀĞŶƟŶŐŝŶƐƚĂůůĂƟŽŶ͘ LIMITATIONS OF LIABILITY ͻ dŚĞŽǁŶĞƌ͛ƐĞdžĐůƵƐŝǀĞƌĞŵĞĚLJĂŶĚ,,d͛ƐƐŽůĞŽďůŝŐĂƟŽŶƵŶĚĞƌƚŚŝƐǁĂƌƌĂŶƚLJ͕ƵŶĚĞƌĂŶLJŽƚŚĞƌǁĂƌƌĂŶƚLJ͕ĞdžƉƌĞƐƐŽƌŝŵƉůŝĞĚ͕ŽƌŝŶ ĐŽŶƚƌĂĐƚ͕ƚŽƌƚŽƌŽƚŚĞƌǁŝƐĞ͕ƐŚĂůůďĞůŝŵŝƚĞĚƚŽƌĞƉůĂĐĞŵĞŶƚ͕ƌĞƉĂŝƌ͕ŽƌƌĞĨƵŶĚ͕ĂƐƐƉĞĐŝĮĞĚĂďŽǀĞ͘/ŶŶŽĞǀĞŶƚǁŝůů,,dďĞůŝĂďůĞĨŽƌ ĂŶLJŝŶĐŝĚĞŶƚĂůŽƌĐŽŶƐĞƋƵĞŶƟĂůĚĂŵĂŐĞƐĐĂƵƐĞĚďLJĚĞĨĞĐƚƐŝŶƚŚĞĂƉƉůŝĂŶĐĞ͘^ŽŵĞƐƚĂƚĞƐĚŽŶŽƚĂůůŽǁĞdžĐůƵƐŝŽŶƐŽƌůŝŵŝƚĂƟŽŶŽĨ ŝŶĐŝĚĞŶƚĂůŽƌĐŽŶƐĞƋƵĞŶƟĂůĚĂŵĂŐĞƐ͕ƐŽƚŚĞƐĞůŝŵŝƚĂƟŽŶƐŵĂLJŶŽƚĂƉƉůLJƚŽLJŽƵ͘dŚŝƐǁĂƌƌĂŶƚLJŐŝǀĞƐLJŽƵƐƉĞĐŝĮĐƌŝŐŚƚƐ͖LJŽƵŵĂLJĂůƐŽ ŚĂǀĞŽƚŚĞƌƌŝŐŚƚƐ͕ǁŚŝĐŚǀĂƌLJĨƌŽŵƐƚĂƚĞƚŽƐƚĂƚĞ͘yWddKd,ydEdWZKs/z>t͕,,dD<^EKyWZ^^tZZEd/^ Kd,Zd,Ed,tZZEdz^W/&/,Z/E͘d,hZd/KEK&Ez/DW>/tZZEdz/^>/D/ddKhZd/KEK&d, yWZ^^tZZEdz^W/&/Ks͘ Based on CSA P.4.1-2015 EFFICIENCY RATINGS MODEL ENERGUIDE RATINGS STOVE EFFICIENCY PERCENTAGE (AFUE PERCENTAGE) SDDVT Series SDVTSC Series D.O.E. 0RXQWDLQ+RXVH5RDG+DOLID[3$ ZZZYHUPRQWFDVWLQJVFRP 64 Vermont Castings • Stardance SDDVTSB Installation Manual_R18 • 11/18 3-90-20306760 ">
Advertisement