Secure CentaurPlus C17-ZW User And Installation Instructions Manual

Add to My manuals
16 Pages

Secure CentaurPlus C17-ZW is a timeswitch with a Z-Wave RF interface, allowing control by a 3rd party controller. It features a simple user interface for local programming, with up to 3 ON/OFF periods per day and different timings for each day of the week. The boost function provides a 1-hour temporary override, while the advance function brings forward the next ON/OFF operation. Override facilities include AUTO (follows programmed times), ALL DAY (operates from 1st ON to 3rd OFF, ignoring intermediate times), 24HRS (constantly ON), and OFF (constantly OFF with boost still available).

advertisement

Secure CentaurPlus C17-ZW User And Installation Instructions Manual | Manualzz

CentaurPlus ZW Timeswitch

User and Installation Instructions

The Secure CentaurPlus C17-ZW has the functionality of a timeswitch with the addition of a Zwave RF interface, providing the additional capability of being controlled by a 3rd party controller.

CentaurPlus C17-ZW allows the schedule to be locally programmed and maintained, providing the user with up to 3on /offs per day with different timings possible for each day of the week.

While CentaurPlus C17-ZW remains in an off period all remote commands will be ignored, providing the user with full control of the schedule through an already well established user interface

1

User Instructions

The CentaurPlus C17-ZW Timeswitch

The simple instructions contained in this user guide are designed to help with the programming and operation of the unit.

1 14 15 2 16

10

17

3

11

12

13

9

2

4 5 6 7 8

1 SET indicator - RUN is the normal position

2 Time of day

3 Switch period symbol

4 SET button

5 BOOST or adjust (-) button

6 ADVANCE or adjust (+) button

7 ENTER button

8 SELECT or COPY button

9 System ON indicator

10 SETTING positions

11 PROGRAMME settings

12 BOOST symbol

13 ADVANCE symbol

14 AM/PM symbol

15 Day of week indicator

16 PROGRAMME indicator

17 RF signal indications

The indicator against the radio mast symbol on the

CentaurPlus ZW shows that the radio link is established.

A flashing indicator means that the wireless connection

has been temporarily lost.

• If no indicator is present next to the radio mast symbol

then this would suggest that the CentaurPlus ZW has

not been paired correctly on installation.

Manual Overrides

BOOST FUNCTION - 1 hOUr TeMPOrary OverrIde

The boost facility will allow the user to boost the system which is currently ‘OFF’ for 1 hour.

To indicate the boost being activated BOOST will be shown on the display for the duration of the boost period. The system ON indicator will also be illuminated.

Press BOOST button: your system will be boosted for

1 hour

 at any time during a BOOST period press

BOOST again to return to normal programming

RUN

CLOCK

PROG

PM

6:35

BOOST

AUTO

ALL DAY

24 HRS

OFF advaNCe FUNCTION – BrINgS FOrWard The NexT ON Or OFF OPeraTION

The advance facility will allow the user to advance the system to ‘ON’ when currently ‘OFF’ or switch the system ‘OFF’ when currently ‘ON’. To indicate the advance feature being activated ADVANCE will be shown on the display until the next programme switching time.

The system ON indicator will also be illuminated.

Press advaNCe button once to move to the next ON/OFF time

To cancel the advance press the advaNCe button again. This will return the unit to its normal programme

RUN

CLOCK

PROG

PM

6:35

ADVANCE

AUTO

ALL DAY

24 HRS

OFF

3

Programme Override Facilities

With the CentaurPlus C17-ZW timeswitch operating in the normal running mode it is possible to alter the functionality of the programme by means of the SELECT button.

The options include: aUTO

24hrs

-

-

Timeswitch follows all programmed ‘ON’ and ‘OFF’ times.

all day - Timeswitch operates from 1st ‘ON’ time until 3rd ’OFF’, ignoring all switching times in between.

Timeswitch will be constantly ‘ON’.

OFF - Timeswitch will be constantly ‘OFF’, there is the ability to turn off the heating during the summer without altering the programme times.

Boost is still available.

All of the settings above will be permanent, i.e. unaffected by programme times, until alteration by the user.

The diagram below illustrates how to alter the setting, it assumes that the programme is in the AUTO mode to begin with.

Press SeleCT once.

Programme goes from aUTO to all day

Press SeleCT again.

Programme goes from all day to

24 hrS

Press SeleCT again.

Programme goes from

24 hrS to OFF

Press SeleCT again.

Programme goes from

OFF to aUTO

4

Timeswitch will operate from 1st ON until 3rd OFF period

Timeswitch will be continuously

ON

Timeswitch will be continuously

OFF

Programme will return to normal

ON and OFF times

PM

6:35 AUTO

ALL DAY

24 HRS

OFF

PM

6:35 AUTO

ALL DAY

24 HRS

OFF

PM

6:35 AUTO

ALL DAY

24 HRS

OFF

PM

6:35 AUTO

ALL DAY

24 HRS

OFF

resetting the Timeswitch

Electronic equipment can in some circumstances be affected by electrical interference.

If the timeswitch display becomes frozen or scrambled; or if you wish to revert back to the default time settings please reset by pressing the SET and SELECT buttons together as shown below.

After initial installation it is advisable, before programming the CentaurPlus ZW for the first time, to reset the unit. Resetting can only be achieved with the power ‘ON’ by pressing the SET and SELECT buttons together. This will return the timeswitch to the factory set default times.

SELECT

Press the SeT and SeleCT buttons together then release the buttons and the timeswitch will return to preset factory settings

SET

Setting Time of day and date

The CentaurPlus C17-ZW timeswitch has a built in clock and calendar. This will mean that you will need to enter the date as well as the time on initial set up or if the factory re-set has been used. Having done this, the clock will automatically adjust for BST/GMT time changes throughout the year.

Press the set button until the set indicator is next to the ‘clock’ position

Use the

+ and –

 buttons to adjust

 the hour and press eNTer

Use the

+ and – buttons to adjust the minutes and press eNTer

Use the

+ and – buttons to set the date and press eNTer

Use the

+ and –

 buttons to set the month

 and press eNTer

Use the

+ and – buttons to set the year and press eNTer

Once the year is set and the eNTer button is pressed the process is complete and the display will return to the run position

Check that the correct time and day are showing in the display. If the wrong day is showing in the display that would indicate that the date has not been set correctly and the above process should be repeated

5

Setting the On and Off Times

To alter these settings please proceed as follows:-

Press the

SeT button until SeT indicator is next to PrOg position

Use PlUS and

MINUS buttons to adjust day

 Press eNTer

Use PlUS and

MINUS buttons to adjust

1st ON time

Use PlUS and

 Press eNTer

MINUS buttons to adjust

1st OFF time

Press eNTer

 repeat this process for

2nd and 3rd settings

 enter the 3rd

OFF time and the word COPy is displayed

To follow the copy route and repeat all programmed times for another day go to 1

To set independent times for other days go to 2

1

Use the PlUS and MINUS buttons to select day required and press COPy.

‘IN’ is displayed to confirm the copy. repeat for other days as required

To transfer to independent times for other days go to 2 or to finish programming press the SeT button until the SeT indicator is in the rUN position

2

Press eNTer. Use the plus and minus buttons to select the day required and press eNTer. Set 1st, 2nd and

3rd times as before. To repeat for other days go to 2, to copy go to 1

To finish programming press the SeT button until the SeT indicator is in the rUN position deFaUlT TIMe SeTTINgS

1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF

6.30AM 8.30AM 12.00PM 12.00PM 4.30PM 10.30PM

The default time settings shown above are preset at the factory

6

NB. The factory default settings for the 2nd ON/OFF times are both set at 12:00pm

(midday) which cancels this ‘ON’ period giving 2 ON/OFF periods for the day. If a midday

‘ON’ period is required set the 2nd ON and OFF times accordingly. If not press ENTER twice.

relay Operation:

The relay of CENTAURPLUS C17-ZW will operate only when it is operating in an ON schedule and it has received an ON command from the controller (Basic Set or Binary Switch Set).

If CENTAURPLUS C17-ZW is operating in an OFF schedule or it has received an OFF command from the controller CENTAURPLUS C17-ZW will turn OFF the relay.

7

8

For the installer

Installation and connection should only be carried out by a suitably qualified person and in accordance with the current edition of the IEE wiring regulations.

WARNING: Isolate mains supply before commencing installation.

An example circuit diagram for a typical combi boiler installation is shown below. This diagram is schematic and should be used for guidance only.

CONTROLLER

Wireless link

N

CentaurPlus ZW

L 1 2 3 4

TERMINALS L-2

SHOULD NOT

BE LINKED

E

MaINS

SUPPly

N

L

For precise terminal connection information please refer to boiler manufacturer's instructions

REMOVE LINK

IF REQUIRED

E N L cOMBINATION BOILER TERMINALS

Fitting the backplate

Once the backplate has been removed from the packaging please ensure the timeswitch is re-sealed to prevent damage from dust, debris.

The backplate should be fitted with the wiring terminals located at the top and in a position that allows a total clearance of at least 50mm around the unit.

direct wall mounting

Offer the backplate to the wall in the position where the timeswitch is to be mounted, remembering that the backplate fits to the left hand end of the control. Mark the fixing positions through the slots on the backplate (fixing centres of 60.3mm), drill and plug the wall, then secure the plate in position. The slots in the backplate will compensate for any misalignments of the fixings.

Wiring box mounting

The backplate may be fitted directly onto a single gang steel flush wiring box complying with BS4662, using two M3.5 screws. CentaurPlus controls are suitable for mounting on a flat surface only; they must not be positioned on a surface mounted wall box or on unearthed metal surfaces.

9

10

electrical Connections

All necessary electrical connections should now be made. Flush wiring can enter from the rear through the aperture in the backplate. Surface wiring can only enter from beneath the timeswitch and must be securely clamped. The mains supply terminals are intended to be connected to the supply by means of fixed wiring. Recommended cable sizes are

1.00 or 1.5mm.

CentaurPlus timers are double insulted and do not require an earth connection but an earth connection is provided on the backplate for terminating and cable earth connectors.

Earth continuity must be maintained and all bare earth connectors must be sleeved.

Ensure no earth conductors are left protruding outside the central space enclosed by the backplate.

Internal diagram - C17-ZW

The CentaurPlus ZW has voltage free contacts.

A link L-2 is required for mains voltage applications

N L 1 2 3 4

230V 50V COMM OFF ON

rear view of CentaurPlus timeswitch

1 - RATINGS LABEL

2 - BATTERY

3 - CONNECTOR PINS

4 - PRODUCTION DATE LABEL

1 4

3

2

+

Battery reserve

The battery must be commissioned prior to fitting the timeswitch to the backplate. This is achieved by the means of a commissioning strip situated in the back of the unit. Pull out the battery commissioning strip at the back of the timeswitch and re-insert the battery; the reserve is now activated. When the timeswitch is running the battery reserve clock display will disappear. This is to prolong the life of the battery.

Fitting the timeswitch

end view of CentaurPlus timer

If surface wiring has been used, remove the knockout/insert from the bottom of the timeswitch to accommodate it.

Loosen the two ‘captive’ retaining screws on the bottom of the backplate. Now fit the timeswitch to the backplate, ensuring the lugs on the backplate engage with the switch.

Swing the bottom of the timeswitch into position ensuring that the connection pins on the back of the unit locate into the terminal slots in the backplate.

Tighten the two captive retaining screws to fix the unit securely.

Then switch on the mains supply.

On completion of the installation please reset the timeswitch as detailed next;

resetting the timeswitch

On the CentaurPlus press the SET and SELECT buttons together. Then release the buttons and the timer will return to preset factory settings

The preset factory settings are illustrated on page 6.

SELECT

SET

The unit is now ready to be signed on to a Zwave network.

11

12

Instructions for pairing CentaurPlus ZW

This devices use the latest Z-Wave wireless communication technology to give a reliable wireless link that should not suffer from interference from other nearby devices.

Follow these steps to ensure that the CentaurPlus C17-ZW will communicate satisfactorily with its controller.

Inclusion/exclusion

If the display against the radio aerial symbol is not present it means the device is not included in any network.

For inclusion, put the controller in inclusion mode and press and hold the ‘Boost’ and

‘Enter’ buttons on the front of the CENTAURPLUS C17-ZW . Once included the indictor next to the radio symbol will appear (solid)

Now check the CentaurPlus ZW is receiving signals from the controller by turning

CentaurPlus ZW to an ‘On’ setting with the red indicator light lit. Now send an on/off command from the controller.

N.B. There is a half second delay in switching On and Off on receipt of the commands.

There will be an audible ‘click’ from the CentaurPlus ZW when the relay toggles.

For exclusion put the controller in exclusion mode and

Press and hold the ‘Boost’ and ‘Enter’ buttons on the front of the CENTAURPLUS C17-ZW until an indicator disappears in its display against the radio aerial symbol.

If the Icon next to the RF symbol is flashing, then the unit has lost communication with the controller, try to move the controller closer.

Press and hold ‘BOOST’ and ‘ENTER’ buttons to ‘SIGN ON’ or ‘PAIR’ the

HRT4 ZW thermostat

The device classes supported are given below.

Z-Wave device Classes

Generic

Specific

Basic

Command Classes

Manufacturer Specific

Version

Binary Switch

Basic

Application Status

Implemented device Class

BINARY SWITCH

SPECIFIC TYPE NOT USED

ROUTING SLAVE.

description

SECURE CONTROLS UK LTD

Provides the version number of the software

Supports SET and GET to control the relay

The Basic Command Class has been mapped to the Binary switch Command

Class as follows:

Basic SET

Basic GET

Basic REPORT

Set the Relay Status.

Relay State GET.

Relay State REPORT

Application Busy Command has been Implemented for the

SET command. While CentaurPlus C17-ZW is in a scheduled off period the SET command will be queued and executed when the unit is entering an active state.

Application Reject Request Command – Not implemented

Note: All command classes are version 1 unless otherwise stated.

Note: The CENTAURPLUS C17-ZW is mains operating device and a routing slave so it will route the RF messages in network.

13

14

general Information

BaTTery

The timeswitch is fitted with a non-rechargeable, long life battery, which will maintain the programmed time settings for a minimum of ten months with the supply disconnected.

THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT.

During power interruptions the display will be blank, after 3 days the current time of day will be lost. These measures are to prolong the battery life.

ServICe aNd rePaIr

This timeswitch is NOT user serviceable. Please do not dismantle the unit.

In the unlikely event of a fault developing please refer to the RESETTING THE TIMESWITCH section of this user guide shown above. If this fails to resolve the problem please contact your installer, a local heating engineer or a qualified electrician.

Timeswitch specification CentaurPlus ZW

Contact Rating 3 (1) Amps 230V AC

Contact Type Micro-disconnection changeover

Supply 230V AC 50Hz only

Class A Software Type 1 Control

Case Material Thermoplastic, flame retardant

Auto BST/GMT changeover

Display Back lit liquid crystal

Battery Life 10 months continuous operation (minimum)

Displayed Time adjustments 1 minute steps

Operating periods per day - 3 per day

(Separate programmers possible for each day of the week)

10 minute steps

Override 1 hour boost, 1 hour extension to On period, instant advance

Mounting Industry standard 6 terminal plug in wall plate

Design Standard EN60730-2-7

IP30

EN300-220 R & TTE Directive

EN301-489

Transmitter Frequency 868MHz

Voltage free

Pollution Degree 2

Operating Temperature Range 0°C to +40°C

Dimensions 84mm x 150mm x 29mm

Clock 12 hour AM/PM

For further replacement timeswitch exchange information, please see the ‘Programmer

Wiring and Replacement Guide’ at www.horstmann.co.uk

Use the categories shown under CentaurPlus C11 and C17.

15

16

Secure Controls UK Limited

South Bristol Business Park, Roman Farm Road, Bristol BS4 1UP England

Tel: +44 (0) 117 978 8700 / Fax: +44 (0) 117 978 8701 / e-mail: [email protected]

www.securetogether.com

Leaflet number P84365 Issue 1

advertisement

Related manuals

Frequently Answers and Questions

What does the BOOST function do?
The BOOST function temporarily overrides the current OFF schedule for 1 hour, turning the system ON.
How do I activate the BOOST function?
To activate the BOOST function, simply press the BOOST button.
How do I cancel the BOOST function?
To cancel the BOOST function, press the BOOST button again during the boost period.
What is the ADVANCE function?
The ADVANCE function allows you to manually bring forward the next ON or OFF operation.
How do I activate the ADVANCE function?
To activate the ADVANCE function, press the ADVANCE button once.
How do I cancel the ADVANCE function?
To cancel the ADVANCE function, press the ADVANCE button again.
What are the different program override facilities?
The program override facilities allow you to alter the functionality of the program, including AUTO (follows all programmed times), ALL DAY (operates from 1st ON until 3rd OFF), 24HRS (constantly ON), and OFF (constantly OFF).
How do I change the program override setting?
To change the program override setting, press the SELECT button repeatedly until the desired setting is displayed.
How do I reset the timeswitch?
To reset the timeswitch, press and hold the SET and SELECT buttons simultaneously.
How do I set the time of day and date?
To set the time of day and date, press the SET button until the SET indicator is next to the 'clock' position, then use the + and - buttons to adjust the hour, minutes, date, month, and year.
Download PDF