xpr B100-SA User Manual
The xpr B100-SA is a standalone biometric reader that offers secure and convenient access control using fingerprint recognition. With a capacity to store up to 97 finger templates, it is ideal for small offices, homes, or any application requiring basic access control. The B100-SA features one relay output for door control and one exit button input for request-to-exit functionality.
Advertisement
Advertisement
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with
RoHS directive EN50581:2012
Visual Plus Corporation, s.a.
Drève Richelle 161
WOP G - Bte 34
1410 Waterloo - Belgium www.xprgroup.com
20
B100-SA
Standalone Biometric Reader
RTT
1 Relay Remote Unit and request-to-exit Bu on
B100-SA-KIT
Standalone Biometric Kit
User Manual www.xprgroup.com
v.a3
EN
Contents
1.0 INTRODUCTION
2.0 MOUNTING
..............................................................
..................................................
3.0 SPECIFICATIONS
4.0 A PPLICATION D IAGRAM
..............................................................
.....................................................
2
3
3
4
5.0 WIRING .........................................................................
6.0 R S T ...........................................
6.1 Tapping the sensor ............................................................
6.2 Scrolling the sensor up and down .................................................
7.0 INDICATION ....................................................................
4
5
5
5
5
8.0 Q P ....................................................
8.1
Adding Master Finger and delete all users .........................................
8.2
Add User In Group 1
8.3
Add User In Group 2
...........................................................
...........................................................
6
6
7
7
8.4 Delete user ...............................................................
8.5
Delete All Users in Group 1 .......................................................
8.6
Delete All Users in Group 2 .......................................................
7
7
7
9.0
P AIRING - B IOMETRIC R EA R R U NIT ..............................
9.1
Pairing B100-SA with DINRTT
9.2
Pairing B100-SA with RTT
...................................................
.........................................................
8
8
8
10.0 K D U NLOCK ...........................................................
11.
0 B100-SA P ROGRAMMING M ENU .................................................
8
11.1
Adding Users
11.2 Delete User
11.3 Delete All users
.....................................................................
9
.....................................................................
10
...................................................................
10
11.4
Delete Group of Users
9
.............................................................
11
11.5
Add Administrator
11.6
Delete Administrator
11.7
Settings
...............................................................
12
.............................................................
13
.........................................................................
14
11.7.1
Entry Mode and Backlight .....................................................
15
11.7.2
Buzzer Sound and Remote Relay Touch Function
11.8
Set Door Relay Time ...........................................................
17
1.0 INTRODUCTION
B100-SA is a simple one-door standalone biometric system. The reader can store up to 97 finger templates, it has one relay output and one exit button input. If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also plays the role of request-to-exit push button. Complete setup and programming can be done by scrolling and tapping on the sensor.
The sensor incorporates dedicated sensing hardware to facilitate the detection of “spoofing” attacks based on fake fingers. This data is embedded into the image data stream, and is processed on the processor. The system is capable of detecting and defeating well-known fake finger mechanisms, such as molded “gummy” fingers.
RTT is remote relay control unit for B100-SA(DINB100-SA) biometric reader. If secure installation is needed, the biometric reader can be connected to remote relay unit at secured area, which also plays the role of exit push button. It has one relay output and one exit button input.
www.xprgroup.com
2 www.xprgroup.com
19
www.xprgroup.com
18
2.0 MOUNTING
1.
Ø6.0(3NoS)
Cable
2.
3.
4.
MC-MINI
3 (3 x 30mm)
1 (M3 x 6mm)
5mm
Do not install the device and cabling close to a source of strong electro-magnec fields like radio-transmi ng antenna.
Do not place the device near or above heang equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered.
If the biometric reader is installed and used outdoor, the reader MUST be fi ed with the MC-MINI metal cover available in our accessories in order to protect the sensor from direct rainfall. The operang temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a third party sealed wall mount box (fi ed with addional heater if very low temperature) to keep a constant sensor level performance. XPR™ cannot guarantee the funconality of the product if measures and advice before are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use different readers depending on users.
3.0 SPECIFICATIONS
S PECIFICATIONS DINB100-SA
Fingerprint Capacity:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
Programming:
Master/Admin Fingers:
Image resolution:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
Mounting:
IP Factor:
Storage/Operating Temperature:
Storage/Operating Humidity:
Dimensions(mm):
97 templates
1 x Relay ( 1 A /24V AC/DC )
Yes
Pulse (1, 3, 5, 10, 20, 30, 60sec) or Toggle(ON/OFF)
Finger
By scrolling and tapping on the sensor or by keypad
1 Master and 2 Admin Fingers
Up to 508 DPI
Yes
Yes via converter and windows application
100 mA max.
9-14 V DC
Flush mount
IP65
-20°C to +50°C
5% to 93% RH without condensation
92 x 51 x 25
B100-SA
S PECIFICATIONS DINRTT
Output:
Push Bu on Input:
Door Time:
Backlight ON/OFF:
Buzzer ON/OFF:
Current Consumpon:
Mounng:
IP Factor:
Operang Temperature:
Dimensions: www.xprgroup.com
1 x Relay (2A/24V AC/DC)
1
Pulse (1 to 60sec) or Toggle (ON/OFF)
Yes
Yes
60 mA surface mount
IP40 (indoor use only)
-20°C to +50°C
92 x 51 x 25
3
RTT
4.0 A PPLICATION D IAGRAM 11.0 B100-SA P ROGRAMMING M ENU
11.8 Set Door Relay Time
RTT (Oponal)
1 Relay Remote Unit and request-to-exit Bu on ea
Secur ed Ar
Outside
B100-SA
Standalone Biometric Reader
5.0 WIRING
B100-SA
Standalone Biometric Reader
Red
Black
Pink
Violet
Blue
Green
Orange
Gray
Yellow
White
12V DC
GND
A
B
Tamp
PB
NC
COM
NO
Push Button
Relay
(2A)
RTT
1 Relay Remote Unit and request-to-exit Bu on
Wiring B100-SA
+
12VDC
_ POWER SUPPLY
Red
Black
Pink
Violet
Blue
Green
Orange
Gray
Yellow
White
+
_
PB
NC
COM
GND (PB)
1N4001
Diode
_
+
Electro Magnetic Lock
Wiring B100-SA + RTT (Remote Relay Unit)
12 VDC
+
-
Black
Red
Pink
Violet
Red
Yellow COM
GND Black
Brown 12V out
Pink A (RS485)
Violet
B (RS485)
White NO
+
-
Red
Black
White
Yellow
Gray
Blue
Green
Orange
Pink
Violet
Brown
+12V
GND
NO
COM
NC
TAMP
TAMP
Power Supply
Relay
(2A)
A
B
+12V Out
RS 485
B100-SA www.xprgroup.com
4
RTT
Relay1 time
(for Relay 1 in B100-SA, RTT and DINRTT )
Swipe the Master/Admin finger 8 times x 8
Tap sensor
Blinking row >
BL
BL
BL
BL
Select relay open time
Scroll down to select:
1 sec
3 sec
5 sec
10 sec
BL
BL
BL
BL
20 sec
30 sec
60 sec
Toggle
Tap sensor
OK Beep
Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU
Example:
Task: Put Relay1 to stay acvated 10 seconds.
Scroll Master Finger 8 mes, tap, scroll 3 mes, tap, swipe UP to exit.
www.xprgroup.com
17
Relay2 time
(for Relay 2 in DINRTT Remote Relay Unit)
Swipe the Master/Admin finger 9 mes x 9
Tap sensor
Blinking row >
BL
BL
BL
BL
Select relay open time
Scroll down to select:
1 sec
3 sec
5 sec
10 sec
BL
BL
BL
BL
20 sec
30 sec
60 sec
Toggle
Tap sensor
OK Beep
Back to MAIN MENU
11.0 B100-SA P ROGRAMMING M ENU
11.7 Se ngs
11.7.2 Buzzer Sound and Remote Relay Touch Funcon
Buzzer sound
Remote Relay Touch Function
Buzzer ON/OFF
Scroll down to select:
Remote OFF
Reader OFF
All ON
All OFF
Tap sensor
OK Beep
Touch Button ON/OFF
Scroll down to select:
1 ON
2 OFF
Tap sensor
OK Beep
Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU
Example:
Task: Put the Buzzer OFF.
Scroll Master Finger 10 mes, tap, scroll 4 mes, tap, scroll ones, tap,, swipe UP to exit.
www.xprgroup.com
16
Back to MAIN MENU
6.0 R S T
Follow the below instructions for correct finger swiping
Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep
( 3 short beeps)
6.1 Taping the sensor
Tap the sensor to enter Submenu or to confirm a command
Enter and confirm
6.2 Scrolling the sensor up and down
Scroll the sensor DOWN to navigate the programming menu
Navigate the Programming Menu
Scroll the sensor UP to exit the programming menu
Exit the Programming Menu
7.0 INDICATION
Tricolor Status LED
Green - Access Granted
Red - Access denied
Orange - Idle Mode www.xprgroup.com
4 x Tricolor Programming LEDs
(red, green, orange)
5
OK Beep - short + long beep
Error Beep - 3 short beeps
Swipe Again - 2 short beeps
8.0 Q
8.1 Adding Master Finger and delete all users
11.0 B100-SA P ROGRAMMING M ENU
11.7 Se ngs
11.7.1 Entry Mode and Backlight
Entry MODE
1.Push dip switch no.2 in position ON.
ON
1 2
No.2
2.Reset the Power of the device.
3.Wait for One long + mulple short beeps
4.Put the dip switch in position OFF.
(short beeps will stop)
5.Wait for the bo om row LEDs to blink in Orange.
ON
1 2
No.2
Blinking> <Blinking
6.Swipe the Master finger min.6 mes . (Unl Ok Beep) x 6
Note: Aer enrolling the Master finger the device will auto-Reset (wait for 7 seconds and the OK beep).
Note: This procedure also deletes all the users and administrators previously enrolled.
BL
BL
BL
BL
By swiping finger select entry mode
Finger
Scroll down to select:
Finger AND Card
BL
Finger OR PIN Finger ON Card
BL
Finger AND PIN
Finger OR Card
Tap sensor
OK Beep
1. There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs. The Master finger can be changed ONLY with the jumper.
2. There are 2 Administrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master.
3. The User can be assigned to one of the 8 available User Groups. With the Quick programming feature, the Users are assigned in Group 1 or Group 2. For most of the installaons 2 groups are enough and can be used as: Group
1 for permanent residents, Group 2 for guest and visitors.
4. The user can be deleted by swiping its user finger or by deleng the group in which that user is enrolled. Once the Group of users is deleted, all the users within that group will be deleted.
5. The Groups are not limited by the number of users. (ex. Group 1 can contain 20 users, Group 2 can contain 70 users, but the total number must remain bellow 97...) www.xprgroup.com
6
Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU
Example:
Task: Set the Reader to work in “Finger and Card” mode
Scroll Master Finger 10 mes, tap, scroll twice, tap, scroll 4 mes, tap, swipe UP to exit.
www.xprgroup.com
15
Backlight
Backlight ON/OFF
Scroll down to select:
Remote OFF
Reader OFF
All ON
All OFF
Tap sensor
OK Beep
Back to MAIN MENU
11.0 B100-SA P ROGRAMMING M ENU
11.7 Se ngs
Swipe the Master/Admin finger 10 mes unl the light pa ern on figure.7 is shown
Figure.7
x 10
Tap sensor
Blinking row >
BL
BL
BL
By swiping finger select appropriate light pa ern
Swipe the finger to select:
Sensor sensitivity
BL
Sensor security
BL
Entry mode
BL
BL
Remote Relay
Touch Function
Buzzer
Backlight
Reserved
Tap sensor
Continues on the next 2 pages
NOTE:
Swipe UPWARDS to exit the MENU
Entry Mode - used when addional proximity or keypad reader is connected
Remote Relay Touch Funcon - Enabling/Disabling the Touch Bu on Funcon in the remote relay Unit
Buzzer - Enabling/Disabling the Buzzer
Backlight - Enabling/Disabling the Backlight go to next page www.xprgroup.com
14
8.2 Add User In Group 1
Figure.1
1. Swipe the Master or Admin Finger
2. Swipe the user finger min.
6 mes (unl Ok Beep)
Master Finger x 1
User Finger x 6
8.3 Add User In Group 2
Figure.2
1. Swipe the Master or Admin Finger twice
2. Swipe the user finger min.
6 mes (unl Ok Beep)
Master Finger x 2
User Finger x 6
8.4 Delete User
Figure.1
1. Swipe the Master or Admin Finger
2. Swipe the user finger (already enrolled)
Master Finger x 1
User Finger x 1
8.5 Delete All Users in Group 1
6 sec.
Figure.4
1. Swipe the Master or Admin finger 3 mes ,
2. Wait 6 seconds for the light pa ern on figure.4
3. Swipe the Master or Admin finger once more
Note: All fingers that are enrolled in Group 1 will be deleted.
8.6 Delete All Users in Group 2
6 sec.
Figure.6
1. Swipe the Master or Admin finger 4 mes ,
2. Wait 6 seconds for the light pa ern on figure.6
3. Swipe the Master or Admin finger once more
Note: All fingers that are enrolled in Group 2 will be deleted.
Master Finger x 3 wait 6 seconds
Master Finger x 1
Master Finger x 4 wait 6 seconds
Master Finger x 1
If you make any mistake or you just simply want to exit Quick Programming, wait for the meout of 10 seconds .
With this, the quick programming is completed. The system is now operaonal with default value for Door Open Time of 3 seconds.
For more comprehensive programming, refer to the “ B100-SA Programming ” secon.
www.xprgroup.com
7
9.0 P AIRING - B IOMETRIC R EA DER AND R EMOTE R ELAY U NIT
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also plays the role of request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote
Relay’s Manual.
9.1 Pairing B100-SA with DINRTT
12 VDC
+
-
DINRTT
+
-
1 2
Black
Red
Pink
Violet
Exit Button
(NO)
GND
P
B
1
GND
B
1
GND
B
2
GND
+12V
B
(RS485)
A (RS485)
485
485
TAMP
TAMP
-
+
12 VDC
1. Close the Jumper. DINRTT beeps connuously and the red led blinks.
2. Open the Jumper
3. Wait for Beep + OK Beep (short + short + long beep)
Aer the OK beep, the coupling is done.
9.2 Pairing B100-SA with RTT
12 VDC
+
Black
Red
Pink
Violet
Red
Yellow
Black
COM
GND
Brown 12V out
Pink A (RS485)
Violet
B (RS485)
White NO
+
-
ON
1 2
11.0 B100-SA P ROGRAMMING M ENU
11.6 Delete Administrator
Swipe the Master/Admin finger 13 mes unl the light pa ern on figure.11 is shown
BL
BL
BL
Figure.11
Tap sensor
Select Admin nr.
Scroll down to select:
Admin 1
Admin 2
Tap sensor deleting..
x 13
B100-SA RTT
1. Put Dipswitch No.1 to posion ON. RTT beeps connuously and the red led blinks.
2. Put Dipswitch No.1 to posion OFF.
3. Wait for Beep + OK Beep (short + short + long beep)
Aer the OK beep, the coupling is done.
10.0 K EEP THE D OOR U NLOCKED
Swipe ANY enrolled finger twice (within 7 seconds) and the Door will stay unlocked, unl valid finger is swiped.
While the door is unlocked the tricolor status LED stays green.
www.xprgroup.com
8
User Finger x 2
OK Beep
Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU
- There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs.
- The Master finger can be changed ONLY with the jumper.
- There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master.
www.xprgroup.com
13
11.0 B100-SA P ROGRAMMING
11.5 Add Administrator
M ENU 11.0 B100-SA P ROGRAMMING M ENU
11.1 Adding Users
Swipe the Master/Admin finger 5 mes unl the light pa ern on figure.9 is shown
BL
Figure.9
x 5
Swipe the Master/Admin finger 12 mes unl the light pa ern on figure.10 is shown
BL
Figure.10
x 12
Tap sensor
BL
BL
Select Admin nr.
Scroll down to select:
Admin 1
Admin 2
Tap sensor
(Orange Blinking)
Swipe the Admin finger min.6 mes.
(Unl Ok beep) x 6
Tap sensor
BL
BL
BL
BL
BL
Select User Group
Swipe the finger to select:
Group 1
Group 2
Group 3
Group 4
BL
BL
BL
BL
Group 5
Group 6
Group 7
Group 8
Tap sensor
BL
BL
Assign Relay Output
Swipe the finger to select:
Relay 1
Relay 2
BL
BL
Both
None
NOTE:
Swipe UPWARDS to exit the MENU
Tap sensor
(Orange Blinking)
Swipe the user finger for Finger mode min.6 mes.
Back to MAIN MENU
(to Add User menu)
NOTE:
Swipe UPWARDS to exit the MENU
- There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs.
- The Master finger can be changed ONLY with the jumper.
- There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master.
www.xprgroup.com
12
Example:
Task: Add a user in Group2, that will acvate Relay1.
Scroll Master Finger 5 mes, tap, scroll ones, tap, tap, swipe user finger 6 mes, swipe UP to exit.
www.xprgroup.com
9 x 6
11.0 B100-SA P ROGRAMMING M ENU
11.2 Delete User
Swipe the Master/Admin finger 7 mes unl the light pa ern on figure.12 is shown
Figure.12
x 7
Tap sensor
Blinking row >
Swipe finger
NOTE:
Swipe UPWARDS to exit the MENU
11.3 Delete All Users
OK Beep Back to MAIN MENU
Swipe the Master/Admin finger 11 mes unl the light pa ern on figure.14 is shown
Figure.14
x 11
NOTE:
Swipe UPWARDS to exit the MENU www.xprgroup.com
11.0 B100-SA P ROGRAMMING M ENU
11.4 Delete Group of Users
Swipe the Master/Admin finger 6 mes unl the light pa ern on figure.13 is shown
Figure.13
x 6
Tap sensor
BL
BL
BL
BL
Select User Group to Delete
Swipe the finger to select:
Group 1
Group 2
Group 3
Group 4
BL
BL
BL
BL
Group 5
Group 6
Group 7
Group 8
Tap sensor
Tap sensor
OK Beep
Blinking row >
Tap sensor to confirm or swipe UP to Cance l deleting...
OK Beep
10
Note: The Master and the Administrators will not be deleted
Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU
Example:
Task: Delete all users in Group3
Scroll Master Finger 6 mes, tap, scroll twice, tap, swipe UP to exit.
www.xprgroup.com
Back to MAIN MENU
Note: All fingers that are enrolled in the Group will be deleted.
11

Public link updated
The public link to your chat has been updated.
Advertisement