Installation and operating instructions

Under-counter chiller and wall-recessed chilled water systems

Model: CH103 Under-counter chiller

Model: CH104 Wall-recessed chiller

Affix model number label here

Page 1 of 12 Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

Contents

Safety information ......................................................................................................................................... Page 2

Technical data ............................................................................................................................................... Page 3

Spare parts and accessories .......................................................................................................................... Page 3

General installation instructions ..................................................................................................................... Page 4

CH103 ChillTap ® installation instructions ....................................................................................................... Page 5

CH103 and CH104 configuration diagram ...................................................................................................... Page 6

CH104 Wall Fountain installation instructions................................................................................................. Page 7

Commissioning .............................................................................................................................................. Page 9

Operation ....................................................................................................................................................... Page 9

Filter replacement .......................................................................................................................................... Page 9

Cleaning ...................................................................................................................................................... Page 10

Service ........................................................................................................................................................ Page 10

Warranty information and End of life disposal .............................................................................................. Page 11

Contact details ............................................................................................................................................. Page 12

Safety information

Please read all installation requirements, installation procedures and precautions before installing any Zip product.

Never attempt to install a Zip product without reading all of the applicable instructions.

Installation, commissioning and maintenance of this appliance must only be carried out by a competent installer who will then be responsible for adhering to all relevant standards and regulations.

Appliance to be wired to a double pole switched fused spur with a minimum breaking capacity of 13 amps and protected by a suitably rated RCD.

Installation must comply with current IEE regulations and any local authority requirements.

This appliance must be earthed.

Check that the power supply is switched off prior to electrical connection.

The appliance, its wiring and piping must not be modified in any way.

In case of malfunction isolate the electricity supply immediately. In case of leaks also isolate the incoming mains cold water supply. Repairs must only be carried out by Zip Heaters (UK) Ltd or an authorised Zip service engineer.

If the power supply cable is damaged it must be replaced by a Zip service engineer or a qualified electrician.

The power supply cable must be adequately secured.

Do not remove the appliance cover under any circumstances without first isolating the appliance from the electricity supply.

Page 2 of 12 Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

Safety information

continued

This appliance must not be used by any person (including children) with limited physical, sensorial or mental abilities or failing experience and / or knowledge unless they are supervised by a person responsible for their safety, or received instructions about how to use the appliance.

Children should be supervised in order to make sure that they do not play with the appliance.

The appliance must only be used when correctly functioning and installed.

This product is approved to the LVD and EMC directives and is CE marked.

This product has been examined, tested and found, when correctly fitted, to comply with the requirements of the United Kingdom Water

Regulations / Byelaws (Scotland).

The products are listed under the WRAS (Water Regulations Advisory Scheme)

Water Fittings and Materials Directory.

Zip Heaters (UK) Ltd cannot be held liable for any damages caused by failure to observe these instructions.

Leave these instructions with the end user after installation.

Technical data

Concealed filtered water chiller with heavy duty lever action tap.

Delivers 140 glasses per hour of chilled filtered water within the operating range of 5ºC to 10ºC.

15mm compression fitting connecting to mains water supply.

A potable water supply is required with minimum water pressure of 0.17 MPa (1.7 bar). If the incoming mains cold water supply pressure exceeds 0.7 MPa (7.0 bar) a pressure reducing valve is required to be fitted in the supply line. (See

Spare parts and accessories below).

Power Supply: 1/N/PE 230 V AC.

Power Rating: 450 W.

Chiller type: Fan cooled condenser with compressor.

Storage capacity: 1.8 Litres.

Refrigerant type: Non-toxic R134A.

Heavy duty ChillTap ® , chrome plated brass, self return lever action, vented with swivel head.

Filtration type: Submicron filtration.

Chiller unit dimensions: Height: 385mm, Width: 355mm, Depth: 290.

Weight: Full 24Kg, Empty 22.2Kg

Spare parts and accessories

Spare parts

Part No. Description

SP99249 Heavy duty ChillTap ®

ZT502 Sub micron filter

Page 3 of 12

Optional accessories

Part No. Description

HE45004** Water block (water shut down system)

ZI001

AQ3

Bubbler, non-vented system kit

Pressure reducer set at 0.35 MPa (3.5 bar)

Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

HE45004

Push fit fittings

Water block

** The recommended optional Water block is ideal for limiting potential leakage and resulting water damage from water chillers and their supply pipe work, which are subject to mains water pressure.

It is easily installed via standard 3/4” BSP water connection and can be pre-set from 5 to 50 litres. The Water block also incorporates a non-return valve.

General installation instructions

Precautions

The plumbing installation must be undertaken in accordance with local water authority regulations and these Installation instructions.

As the installer, it is your responsibility to supply (if necessary) and install all valves as required by local regulations and relevant standards.

The chiller and filtration systems are indoor units and must not be exposed to the elements.

Take care, when bending rigid plastic tubing, to prevent it from kinking or crushing around a bend. The plastic tubing contains water under mains pressure, be careful not to nick, scratch or damage it during installation.

Cut the tube squarely with a sharp knife or tube cutter. Shake out and remove any swarf and debris before connection.

Ensure there is adequate ventilation available through the chiller space. If there is inadequate ventilation, and the chiller space temperature rises to above 40°C, the chiller may become damaged and malfunction, which will void the product warranty.

For the CH103 there must be a minimum 168cm 2 of cross-flow ventilation. Suitable holes or vents will need to be cut into the cupboard and door.

If the incoming mains cold water supply pressure exceeds 0.7 MPa (7.0 bar) a pressure reducing valve is required to be fitted in the supply line, (see Spare parts and accessories, page 3).

Electrical

Electrical connection must be made by a Zip service engineer or a qualified electrician. (See Safety information, page 2).

This appliance must be earthed.

DO NOT turn the electricity supply on until the system has been purged. (See

Commissioning, page 9).

Page 4 of 12 Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

Page 5 of 12

CH103 ChillTap

®

installation instructions

Refer to the configuration diagram page 6.

Note It is important to install an isolating valve (not supplied) in the incoming mains cold water supply line before the connection to Zip chiller products.

Installing the chiller and filter head

Site the under counter chiller unit into the cupboard as close to the dispensing tap position as is possible, to minimise the length of tubing exposed between the chiller unit and the dispensing tap. Secure the filter head to the wall, cupboard side or back (with the 2off 3/4” self tap screws provided) in a convenient location between the incoming mains water supply and the chiller unit, again minimise tube lengths where possible. Allow 260mm minimum clearance between the underside of the filter head and any obstructions .

Allow an envelope of at least 50mm around the chiller unit to permit free airflow.

Both the top and the front of the chiller must remain accessible for servicing purposes.

Electrical connection

Electrical connection must be made by a Zip service engineer or a qualified electrician. (See Safety information page 2).

Connect to water supply

Install the isolation valve (not supplied) in the mains cold water supply line, in the under-counter cupboard space. Using the 15mm compression fitting supplied, connect the pressure limiting multifunction valve assembly to the incoming water supply line.

Note Before assembling the compression fitting to the valve, apply sufficient PTFE tape to the thread to ensure a water tight connection.

Do not turn the water on until the complete system has been connected.

Installing the tap

Install the Heavy duty ChillTap ® in a position where there is a Ø 45mm wide flat area within the draining area of the sink, ensuring that the selected position allows the water from the spout to safely drain away.

Use a 22mm sheet metal punch to create a neat hole without burrs.

Remove the plastic nut and lower rubber washer from the base of the tap, leaving the rubber-sealing ring in place, then fit the tap in place, oriented so that the lever is operated towards the user.

Slide the lower rubber washer and plastic nut over the tap connection tubes, (under the sink), and tighten the nut to secure the tap firmly into place.

Connecting the system together

Note Ensure that the plastic pipes from the chiller unit are insulated with the tube insulation provided, use any tube insulation left over to insulate pipes from the filter head.

The pressure limiting multifunction valve supplied must be fitted.

Ensure that all connections to push fit fittings are pushed in past the O-ring to full depth, at least 15-16mm (see diagrams opposite).

Connect the white tube from the tap to the outlet of the filter housing. (marked with arrow pointing away from filter head), trim to length before fitting.

Connect the red tube from the tap to the push fit fitting marked INLET on the top right rear of the chiller unit, trim to length before fitting.

Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

CH103 ChillTap

®

installation instructions

continued

Connect the blue tube from the tap to the push fit fitting marked OUTLET on the top left rear of the chiller unit, trim to length before fitting.

Connect the white tube (supplied in the tap kit) between the INLET connection on the filter head (marked with arrow pointing towards the filter head) to the pressure limiting multifunction valve, trim to length before fitting.

Use the 4off pipe clamps and 4off 1/2” self tap screws provided to secure tubes appropriately, to prevent applying stress to pipe connections.

CH103 and CH104 configuration diagram

Heavy Duty ChillTap

®

15mm compression fitting

Pressure limiting multifunctional valve

Mains cold water

Filter and head assembly

Outlet Inlet

Chiller unit

Note s

Ensure that the plastic pipes from the chiller unit are insulated with the tube insulation provided, use any tube insulation left over to insulate pipes from the filter head.

Cut pipes should not be overly long, but must allow sufficient length to avoid stress at connection points.

Page 6 of 12 Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

Page 7 of 12

40

CH104 Wall Fountain installation instructions

Zip Wall Fountain should only be installed by a competent installer in accordance with local water authority by-laws and these instructions.

Zip Wall Fountain is designed to be recess mounted within a wall. The bottom should sit on a supporting flat and level plinth at least 100mm above finished floor level. The plinth height determines the final height of the dispensing tap, as the tap base is fixed at 915mm above the bottom of the unit.

Check that there is enough free space within the wall to allow for completely recessing the Wall Fountain. The top half recesses 270mm and the bottom half requires a depth of 350mm to allow for the chiller unit and to provide adequate ventilation space.

Wall cut-out

The cut-out dimensions are 1630mm high by 555mm wide.

The Wall Fountain has a 40mm flange on both sides and the top, designed to cover gaps or rough edges to the recessed aperture. The bottom front edge has no flange, so the plinth must be finished level and neat as it will always remain visible.

Ensure the cut-out is square and even to allow the Wall Fountain to fit without distortion.

635

555 13

270

257

40

1670

1630

915

385 leave space for chiller

355 300 28

Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

CH104 Wall Fountain installation instructions

continued

Refer to the configuration diagram page 6.

Note It is important to install an isolating valve (not supplied) in the incoming mains cold water supply line before the connection to Zip chiller products.

Positioning and installing the Wall Fountain cabinet and chiller unit

Fit the Wall Fountain cabinet into the recessed aperture in the wall until the surrounding flange is flush with the front face of the wall. Anchor the Wall

Fountain securely to prevent movement. Secure the filter head to the wall in a convenient location (with the 2off 3/4” self tap screws provided) between the incoming mains water supply and the chiller unit, minimise tube lengths where possible.

The chiller unit sits on the base tray of the Wall Fountain cabinet.

Allow at least 50mm all around the chiller unit for free airflow ventilation.

Electrical connection

Electrical connection must be made by a Zip service engineer or a qualified electrician. (See Safety information page 2).

Connect to drainage piping

Connect the 40mm PVC drain pipe from the sink bowl to an appropriate waste in accordance with local by-laws.

Keep the drainage piping clear of the chiller space, approx. 380mm above the base tray.

Connect to water supply

Install an isolation valve in the incoming mains cold water supply line in the area behind the Wall Fountain so that it can be accessed through the front louvered panel.

Using the 15mm compression fitting supplied, connect the pressure limiting multifunction valve assembly to the incoming mains cold water supply line.

Note Before assembling the compression fitting to the valve, apply sufficient

PTFE tape to the thread to ensure a water tight connection.

Do not turn the water on until the complete system has been connected.

Installing the tap

Remove the plastic nut and lower rubber washer from the base of the tap, leaving the rubber-sealing ring in place.

Fit the tap in place in the hole provided on the front left hand edge of the basin, oriented so that the lever is operated towards the user.

Slide the lower rubber washer and plastic nut over the tap connection tubes,

(under the sink bowl), and tighten the nut to secure the tap firmly into place.

Connecting the system together

Use the same procedure as CH103 (see CH103 ChillTap ® installlation instructions page 5).

Page 8 of 12 Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

Commissioning

Commissioning

Ensure all pipes and cables are secure. After the system is correctly installed and connected, turn the incoming mains cold water supply on. Check all connections for leaks. Repair as necessary, again turn on the incoming mains cold water supply and then the electricity supply.

The chiller unit takes up to 20 minutes to chill its contents to the rated temperature, depending on the ambient temperature of the water.

Following installation, the chiller system will contain air, which needs to be purged. To purge the system of air follow the instruction in the Filter replacement section below.

CH104 remove the protective wrapping & clean the stainless steel surfaces.

Dispose of the packaging wisely.

Operation

Operation

Chilled water is obtained by pulling the lever on the tap forward. The water is chilled by a refrigeration unit fitted within the under counter chiller.

Using the Heavy Duty ChillTap ®

, you can obtain chilled water within the rated capacity for as long as you pull forward the lever. The lever will self return, and close the tap once finger pressure has been removed.

Pull

Filter replacement

CH103 and CH104

Remove filter

Page 9 of 12

Pull

Rotate

Insert filter

Insert

Rotate

Changing the filter

For safe operation, the filter cartridge should be replaced at least every 6-12 months, or earlier if you notice a persistent reduction in water pressure from the tap or an unpleasant taste or odour in the water.

For safe operation, thoroughly flush the water through after periods of non-use longer than 12 hours.

Not changing the filter cartridges when required may cause the water to become biologically unsafe.

Use only a Zip filter to match the one used in your chiller product (see Spare parts and accessories page 3). The filter cartridge can be obtained through plumbing suppliers or direct from Zip. The filter is located behind the front access panel on the CH104. The installation date should be written on the filter cartridge. No special tools or skills are required to install the filter cartridge.

• For the CH104, unlock the front louvre panel to locate the filter. For the

CH103, locate the filter in the under-sink cupboard.

• Grasp the filter cartridge firmly and twist it horizontally a quarter turn clockwise until it stops.

Some water will drip from the filter head during the replacement process so it is a good idea to have a bucket and cloth handy to catch and mop up any spills.

• Gently ease the cartridge downwards to detach it from the filter head, then pull it out and discard responsibly. Take care not to tip it up once

Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

Filter replacement

continued free as water may spill out.

• Write the date of replacement on the new filter cartridge label.

• Remove the protective plastic cap. The insertion method is the opposite to the removal method. Align the tabs of the replacement cartridge with the filter head and insert it up into the filter head.

• Turn the replacement cartridge a quarter turn anti-clockwise until it stops and locks into position.

• When the filter replacement has been completed, purge the system of trapped air by dispense water from the tap until it flows without any further spluttering. Run the water for at least 2 minutes more to complete the purge.

• For the CH104 refit the front louvred panel, clean any marks on the stainless steel surface, wipe dry any water spills.

Cleaning

Cleaning

Never use strong, corrosive or abrasive cleaning materials on the Zip ChillTap ®

,Wall Fountain or under counter chiller unit. Wipe clean the outer surfaces with a sponge or a soft cloth using a mild soap and water.

The louvres on the sides of the chiller unit and the Wall Fountain cabinet need to be kept free of dust and lint to permit free flow of air through the vents. They should be checked regularly, at least monthly, and dusted or vacuumed.

Service

Service

There are no user serviceable parts but there are dangerous voltages present within the under counter chiller unit. All service work must only be carried out by a suitably qualified and experienced trades-person.

Before calling for service, check that both the water and electricity supplies are turned on and functional.

Call Zip, a qualified electrician or plumber for assistance, service, spare parts, or enquiries.

Zip customer service 0845 6 005 005, 0345 6 005 005.

Page 10 of 12 Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

Warranty information

Certain warranties may be implied by law into your contract with Zip. The warranty provided below is additional to these implied warranties and nothing set out below shall limit your statutory rights or rights at law.

Zip Heaters UK Ltd warrants that, should any part fail within 12 calendar months of installation, that part will be repaired or replaced free of charge by

Zip or its Distributor or Service Provider, except as set out below, provided the appliance is installed and used strictly in accordance with the instructions supplied, and that failure is not due to accident, misuse, abuse, unsuitable water conditions, or to any alteration, modification or repair by any party not expressly nominated by Zip.

No costs are payable by the customer other than any mileage or travelling-time charges incurred by a Zip Service Provider or the cost of removal, cartage and re-installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor.

This warranty does not cover damage resulting from non-operation of the appliance, the use of non-authorised parts or consequential damage to any other goods, furnishings or property.

No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary according to water quality and the rate of water consumption.

Zip does not exclude, restrict or modify any liability that cannot be excluded, restricted or modified or which cannot, except to a limited extent, be excluded, restricted or modified as between the owner or user and Zip under the laws applicable.

Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance.

Registering Your Purchase

Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary to service the appliance under terms of the Zip warranty. To register your installation go to www.zipheaters.co.uk and look under the heading “Warranty” .

In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local council for collection centre details.

End of life disposal

The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste.

Within each of the European Union member countries, provisions have been made for the collection and recycling of unwanted electrical and electronic equipment.

In order to preserve our environment we ask that you dispose of this product correctly.

Please contact Zip customer service for advice on 0845 6 005 005, 0345 6 005 005.

Page 11 of 12 Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

Contact details

Zip Heaters (UK) Ltd,

14 Bertie Ward Way,

Dereham,

Norfolk,

NR19 1TE www.zipheaters.co.uk

Telephone: 0845 6 005 005

0345 6 005 005

Fax: 01362 692448

Web: www.zipheaters.co.uk

e-mail: [email protected]

Page 12 of 12

Registering Your Purchase

Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary to service the appliance under terms of the Zip warranty.

Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04