NOTES
1. Handing of device cannot be changed.
2. Crossbar length equals the distance between the housing vertical center lines minus 1-3/4”.
© Allegion 2014
Printed in U.S.A.
4270101872 Rev. 01/14-d
2
INSTALLATION
1. Check “Series 2090 Parts List” (see page 4).
2. Prepare door for device (see page 3).
NOTE
Dimensions on lock and lock screw holes will function with the following 5-pin tumbler rim cylinders: Corbin,
Lockwood, Schlage, Welch, Yale.
For other brands, refer to lock maker’s template.
3. Aluminum and hollow metal doors: Install housing mounting studs in door.
Wood door: Install assembly plates in door cutouts.
4. Install cylinder if used. If required, cut tailpiece (Figure 1).
Cylinder screw heads must be flush with door surface.
5. If cylinder is used, set pinion cam on back of active housing for hold-back (HB) or night latch (NL) operation (Figure 2).
Hold-back (HB): Turning key one complete rotation retracts latch bolt. If key is removed in this position, latch bolt stays retracted. Returning key to original position before removing allows latch bolt to extend.
To set for hold-back: Turn pinion cam until latch bolt starts to retract, then turn pinion cam the other way as far as it will go.
Leave pinion cam in this position.
Night latch (NL): Turning key as far as it will go retracts latch bolt. Key must be returned to original position to be removed, leaving the door locked.
To set for night latch: Turn pinion cam until latch bolt starts to retract. Leave pinion cam in this position.
6. Install active housing over mounting studs and tighten set screws (Figure 3).
7. Check lever arm operation to ensure that all parts move freely.
If cylinder is used, check that the cylinder functions correctly for either hold-back or night latch.
8. Install crossbar and inactive housing (Figure 4). Tighten inactive housing set screws and fasten crossbar with Taptite screws (item No. 16 in “Series 2090 Parts List,” page 4).
9. Prepare frame for strike and install strike (see bottom of page 4).
Figure 2
Figure 3
Tailpiece
3/16"
Figure 1
Pinion cam
Latch bolt
Figure 4
Aluminum or
Hollow Metal Door
Reinforcing for hollow metal door to be supplied by door manufacturer
LHR shown
RHR opposite
5/64"
5/16" dia.
8 2˚ c'sink
Detail A
METAL DOOR PREPARATION
1/2" ref. typ.
6-1/4"
Face of door
1/8" min.
1/8" min.
stop
13/16"
13/32"
1/4" latch bolt and strike
See strike application
(page 4) for backset device
Inside (exit device side) of lock stile
3/4" min.; for medium and wide stile doors housing may be centered on stile
Surface mounting:
#9 (0.196") drill for aluminum door,
#7 (0.201") drill for hollow metal door, this side, 1/4-20 tap
2 places each stile
Thru bolting:
1/4" dia. this side
13/32" dia. opposite side
2 places each stile tailpiece and device
15/64" dia., 2 places c'sink with 5/16" dia.
drill (see Detail A)
1-3/16" dia.
opposite side
(for rim cylinder)
42" to finished floor
9/16" dia. ream this side
Reinforcing for hollow metal door to be supplied by door manufacturer device
Inside (exit device side) of hinge stile
Face of door stop
6-1/4"
1/2" ref. typ.
Face of door stop
1/8"
WOOD DOOR PREPARATION
See strike application (page
4) for backset
3/4" min.; for medium and wide stile doors housing may be centered on stile device
Reinforcing for hollow metal door to be supplied by door manufacturer device
5/8" dia. x 3/8" deep this side
1/4" dia., 2 places
13/16"
13/32"
1/4"
1-11/16"
42" to finished floor
Inside (exit device side) of lock stile
1-3/16" dia.
opposite side
(for rim cylinder) latch bolt and strike
6 "
Inside (exit device side) of hinge stile
Surface mounting:
No holes needed
Thru bolting:
13/32" dia. thru
2 places each stile
Face of door stop
LHR shown
RHR opposite
Cylinder mounting screws
1/2"
1 "
1/8" deep mortise for assembly plate 1/2"
1 "
Assembly plate
3
4
SERIES 2090 PARTS LIST
17 8
LHR shown
RHR opposite
18
20
19
21
17
Rim cylinder optional, sold separately
5
6
3 8
7
8
18
1
14
4
10
16
19
9
5
6
13 3
4
7
10
11
8
2
14
12
15
16
Item Qty. Description
1
4
5
2
3
6
7
1 Housing, active (RHR or LHR)
1 Housing, inactive (RHR or LHR)
4
2
2
4
4
Tension spring
Spring retainer
Axle pin
Retaining ring
Axle bushing
Item Qty. Description
8
9
10
11
12
13
14
6 1/4-20 x 3/8" socket head set screw
1 1/8" Allen wrench
2
1
1
1
2
7/16-14 x 3/4" socket head set screw
Dogging key
Lever arm, LH
Lever arm, RH
Spring pin
Item Qty. Description
15
16
17
18
10
20
21
1 Crossbar
2 1/4-20 x 1" Taptite
4
2
8
1
2
Housing mounting stud (metal doors)
Assembly plate (for wood doors)
#10 x 1" FPHSMS (for wood doors)
Rim cylinder
Rim cylinder screws
SD36 Strike (standard)
1-3/4"
1-1/4"
5/8"
Reinforcing in frame for strike is 3/16" min.
SD35 Strike (optional)
1-3/4"
1-1/4"
5/8"
Double Doors with STK45 Strike
opening
1-1/4" 2-1/8"
1-3/4"
mounting holes
Surface Mounted Strike
1-1/4" backset active housing
1-3/4" mounting holes
Mortised Strike
1-1/4" backset active housing rim panic device concealed vertical rod panic device
Double Doors with RM70 Mullion
1-1/4" opening
1-1/4"
7/8" 7/8"
Rim panic device rim panic device
Strike mounted on face of stop
Strike mortised into stop