INSTALLATION INSTRUCTIONS
HL6T-7500 PULL LATCH
NOTE: DOOR AND FRAME SHOULD BE PREPPED FOR VON DUPRIN 7500 SERIES LOCK.
1
A. INSTALL DOOR.
B. MARK HORIZONTAL CENTERLINE OF MORTISE LOCK CUTOUT ON FACE AND EDGE OF DOOR.
C. PREPARE DOOR AS INDICATED ON TEMPLATE.
LOW EDGE
OF BEVEL
TEMPLATE
CENTERLINE OF MORTISE LOCK CUTOUT
2
INSTALL 7500 SERIES STRIKE PER VON DUPRIN INSTALLATION INSTRUCTIONS.
3
FOR WOOD DOORS ONLY, INSTALL STUD ASSEMBLY (EITHER THRU THE TOP 2 MOUNTING HOLES
FOR VERTICAL PADDLE MOUNTING OR THRU THE FRONT 2 MOUNTING HOLES FOR HORIZONTAL
PADDLE MOUNTING).
4
INSTALL 7500 SERIES LOCK PER VON DUPRIN INSTALLATION INSTRUCTIONS.
5 REMOVE COVER SCREWS AND REMOVE COVER FROM PULL HANDLE ASSEMBLY.
CAM SHOULD BE POSITIONED AS SHOWN BELOW.
ACTUATOR PIN
CAM
LOCK SHAFT
© Allegion 2018
Printed in U.S.A.
829363 Rev. 04/18-c
6
INSTALL PULL HANDLE ASSEMBLY WITH LOCK SHAFT IN KNOB HUB.
7
SECURE PULL HANDLE ASSEMBLY. FOR THE WOOD DOORS USE 4 OF THE #10-32 KEPS NUTS
AND 2 OF THE #10-32 X 2 3/4" FPHMS. FOR METAL DOORS USE 4 OF THE #10-32 X 3/8" TRPHMS.
8
INSTALL LOCK CYLINDERS AS NECESSARY AND SECURE. PADDLES ON KEY SIDE
MUST BE MOUNTED IN DOWN OR HORIZONTAL POSITIONS.
9 INSTALL COVER.
#10-32 KEPS NUT
STUD ASSEMBLY
COVER
#10-32 X 3/8" TRPHMS
COVER
WOOD DOOR APPLICATION
#10-32 X 2 3/4" FPHMS
HOLLOW METAL DOOR APPLICATION
APPLICATION
HANDLE ASSEMBLY
HANDLE ASSEMBLY
HANDLE ASSEMBLY
HANDLE ASSEMBLY
HANDLE ASSEMBLY
COVER
4
4
4
1
QTY
2
2
FASTENER DETAIL
#10-32 X 2 3/4" FPHMS
#10-32 X 2 3/4 TRPHMS
#10-32 KEPS NUT
STUD ASSEMBLY
#10-32 X 3/8" TRPHMS
#6-32 X 3/8" UPHMS