Advertisement
Advertisement
*941030-00*
941030-00
Removable Mullion
1654
Installation Instructions
Note: Use lock washers on top and bottom mullion fittings except for counter sunk screws.
1.
Line up bottom mullion fitting with center of door opening and flush with closeddoors (Figure 1 or 2) and install.
2.
Line up top mullion fitting with center of door opening and flush with closed doors as shown in
Figure 3 and install. See Figures
5, 6, and 7 (reverse side) for optional frame conditions.
3.
Cut mullion body to length as shown in Figure 4.
4.
Insert mullion in top fitting and slide bottom of mullion into place. SeeFigure 8 (reverse side).
5.
Nest mullion into bottom fitting and secure set screw.
6.
Install top mullion clamp over mullion and fitting with mounting screws. See Figure 8 (reverse side).
2
3 15/32”
F-Flat sill fitting shown
Figure 1
If threshold is used, it must be cut to fit around the flat sill fitting
3/16” R. typ.
Door opening
1/4-20 x 5/8” P.P.H.M.S.
5/8
2
5/8
Figure 3
Top anchor
1”
2 7/8”
9/16”
Door opening
1/16” ref.
Door opening Cut off top end of mullion body so length is 1/16” less than this dimension
5/8”
Bottom set screw
Figure 2
Figure 4
Customer Service
1-877-671-7011 www.allegion.com/us
© Allegion 2014
Printed in U.S.A.
941030-00 Rev. 01/14-b
Reinforcement
Top clamp
1 7/16”
15/16”
Figure 5
1/4-20 x 5/8” P.P.H.M.S.
1/4-20 x 1 1/2” P.P.H.M.S.
Reinforcement
Note:
Reinforcement for all sheet metal frames is to be supplied by frame mfg.
Filler block is to be supplied by the frame mfg. for conditions similar to this
Angle plate
Figure 6
The use of this screw is optional depending on frame conditions
For narrow transoms
Reinforcement
1/4-20 x 5/8”
P.P.H.M.S.
Figure 7
2 1/2”
15/16” 15/16”
1 1/2”
Symmetrical about
C L
Adj. angle plate
7/8”
5/8”
1 1/4”
1/4”
1606 Strike
Bottom set screw
5/16 - 18 x 1 1/4
F.P.H.M.S.
Reinforcement
5/16 x 18” anchor
Figure 8