Williams Furnace 5008632 Forsaire Top Vent 4 Tons Gas 50000 BTU Furnace Owner's Manual
Add to My manuals40 Pages
advertisement
Owner’s Manual
S ave this manual for future reference.
Forsaire
Counterflow
Top-Vent Gas Wall
Furnaces
Model Numbers:
3508232; 3518232; 3538232; 3558232; 3508632; 3518632;
3538632; 3558632; 5008632; 5018632; 5038632; 5058632;
5508232; 5518232; 5538232; 5558232; 6508632; 6518632;
6538632; 6558632
FOR USE WITH NATURAL GAS ONLY
Model Numbers:
3508231; 3518231; 3538231; 3558231; 3508631; 3518631;
3538631; 3558631; 5008631; 5018631; 5038631; 5058631;
5508231; 5518231; 5538231; 5558231; 6508631; 6518631;
6538631; 6558631
FOR USE WITH PROPANE GAS ONLY
READ THIS OWNER’S MANUAL CAREFULLY BEFORE YOU
INSTALL YOUR NEW WILLIAMS WALL FURNACE.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing damage, personal injury or loss of life. property
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open all windows.
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone or cell phone in your
building.
Extinguish any open flame.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach the gas supplier,
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or for additional information consult a qualified installer, service agency or the gas supplier.
Williams Furnace Co. 250 West Laurel Street Colton, California 92324 U.S.A.
2
Warranty & Installation Record
– 2
Warranty
The manufacturer, Williams Furnace Co., warrants this wall furnace or heater to the original purchaser under the following conditions:
LIMITED ONE-YEAR WARRANTY
1. Any part thereof which proves to be defective in material or workmanship within one year from date of original purchase for use will be replaced at the Manufacturer’s option, FOB to its factory.
2. No liability is assumed by the Manufacturer for removal or installation labor costs, nor for freight or delivery charges.
LIMITED EXTENDED WARRANTY
1. In addition to the above limited one-year warranty on the complete unit, any combustion chamber which burns out or rusts under normal installation, use and service conditions during a period of nine years following expiration of the one-year warranty period will be exchanged for a like or functionally similar part.
2. No liability is assumed by the Manufacturer for removal or installation labor costs, nor for freight or delivery charges.
LIMITATIONS
1. THIS LIMITED WARRANTY IS THE ONLY WARRANTY MADE BY THE MANUFACTURER, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE ARE LIMITED TO THE SAME ONE YEAR TERM AS THE EXPRESS WARRANTY. UNDER NO CIRCUMSTANCES SHALL THE
MANUFACTURER BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT DAMAGES OR EXPENSES ARISING DIRECTLY OR INDIRECTLY
FROM ANY DEFECT IN THE PRODUCT OR ANY COMPONENT OR FROM THE USE THEREOF. THE REMEDIES SET FORTH HEREIN ARE THE EXCLUSIVE
REMEDIES AVAILABLE TO THE USER AND ARE IN LIEU OF ALL OTHER REMEDIES.
Some states do not allow limitation on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
2. This warranty does not include any charge for labor or installation.
3. This warranty does not extend to painted surfaces or to damage or defects resulting from accident, alteration, misuses or abuse or improper installation.
4. This warranty does not cover claims which do not involve defective workmanship or materials.
DUTIES OF THE CONSUMER
1. The heating equipment must be installed by a qualified installer and operated in accordance with the installation and homeown er’s instructions furnished with the equipment.
2. Any travel, diagnostic costs, service labor, and labor to repair the defective unit will be the responsibility of the owner.
3. A bill of sale, cancelled check, payment record or permit should be kept to verify purchase date to establish the warranty period.
4. Have the installer enter the requested information in the space below.
GENERAL
1. The manufacturer neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with said equipment.
2. Service under this warranty should be obtained by contacting your dealer. Provide the dealer with the model number, serial number, and purchase date verification.
3. If, within a reasonable time after contacting your dealer, satisfactory service has not been received, contact: Customer Service Department, 250 West Laurel Street,
Colton, CA 92324 for assistance.
4. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Installation Record
Model No. ______________________________________________________________ Serial No. ___________________________
Original Purchaser ____________________________________________________________________________________________
Address ____________________________________________________________________________________________________
City and State ___________________________________________________________ Zip ________________________________
Dealer _____________________________________________________________________________________________________
Address ____________________________________________________________________________________________________
City and State ___________________________________________________________ Zip ________________________________
Installation Date _______________ Name ________________________________ Signature_________________________________
(Dealer or authorized representative who certifies that this appliance is installed in accordance with M anufacturer’s instructions and local codes.)
Contents
Your Williams Warranty ................................................................. 2
Installation Record ......................................................................... 2
Table of Contents .......................................................................... 3
Safety Rules .................................................................................. 4
Introduction .................................................................................... 5
Basic Description ........................................................................... 5
Basic Tools Needed ...................................................................... 5
Basic Materials Needed................................................................. 5
Optional Accessories.....................................................................6
Installing Your Wall Furnace .......................................................... 7
Locating Wall Furnace and Thermostat ..................................... 7-8
Combustion and Ventilation Air ............................................... 8-11
Installation
Recessed Mount Installation ........................................ 11-13
Surface Mount Installation ........................................... 13-14
General Vent Installation .............................................. 14-16
Mounting Your Furnace ......................................................... 16-17
Gas Supply and Piping .......................................................... 18-19
Electrical Wiring ........................................................................... 19
Thermostat Installation ................................................................ 20
Start Up Procedure ...................................................................... 21
Operating Your Furnace ........................................................ 22-23
How To Care For Your Furnace ............................................ 24-25
Furnace Technical Information .................................................... 26
TROUBLESHOOTING CHART ............................................. 27-29
Wiring Diagrams .................................................................... 30-31
Repair Parts .......................................................................... 32-35
Repair Parts List .................................................................... 36-39
SERVICE HINTS .......................................................... Back Cover
How To Order Repair Parts .......................................... Back Cover
Quick Reference: Here’s how to…
Unpack the furnace ....................................................................... 6
Learn how to unpack the new Williams Furnace and verify that all its parts are in working order.
Install the furnace..................................................................... 7-21
Recessed Mount, Surface Mount, and Vent Installation is all explained starting on page 11.
Operate the furnace ............................................................... 22-23
Igniting the furnace for the first time.
Caring for Your Furnace ........................................................ 24-25
Learn how to keep your new Williams Furnace operating.
4
Safety Rules
WARNING: Read these rules and the instructions carefully. Failure to follow these rules and instructions could cause a malfunction of the furnace. This could result in death, serious bodily injury and/or property damage.
INSTALLATION MUST CONFORM TO LOCAL CODES. IN THE
ABSENCE OF LOCAL CODES, INSTALLATION MUST
CONFORM TO THE NATIONAL FUEL GAS CODE, ANSI Z223.1.
THE APPLIANCE, WHEN INSTALLED MUST BE
ELECTRICALLY CONNECTED AND GROUNDED IN
ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE
OF LOCAL CODES, WITH THE CURRENT NATIONAL
ELECTRICAL CODE ANSI/NFPA NO. 70.
In Canada :
1. Installation must conform to local codes or, in the absence of local codes, the current
CAN/CGA B149 installation code.
2. The appliance, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1
Canadian Electrical code.
3. Field conversions for high altitude are not permitted in Canada.
4. Reference is made in this manual regarding gas type as L.P.G. Be advised that L.P.G. is not available in Canada, refer to propane/L.P. Gas.
1. Use only manufacturer's replacement parts. Use of any other parts could cause injury or death.
2. DO NOT install the furnace in an alcove.
3. DO NOT install this furnace where it could be isolated by closing doors to the heated space.
4. DO NOT install this furnace in a travel trailer or recreational vehicle.
5. MAINTAIN all clearances specified in section "Locating
Wall Furnace and Thermostat" and "Vent Installation."
6. BE SURE this furnace is for type of gas to be used.
Check the rating plate by the gas valve in the lower cabinet. Do not change it to use other gases without the proper manufacturer’s Gas Conversion Kit.
7. For natural gas, the minimum inlet gas supply pressure for the purpose of input adjustment is 5" water column.
The maximum inlet gas supply pressure is 7" water column.
For L.P. Gas, the minimum inlet gas supply pressure for the purpose of input adjustment is 11" water column. The maximum inlet gas supply pressure is 13" water column.
8. Any safety screen, guard or parts removed for servicing this appliance must be replaced prior to operating the appliance to avoid property damage, bodily injury or death.
9. Install the furnace vent directly to the outdoors so that harmful combustible flue gases will not collect inside the building. Follow the venting instructions for your type of installation exactly. Use only the type and size of vent pipe and fittings specified.
10. BE SURE to provide for adequate combustion and ventilation air. The flow of this air to the furnace must not be blocked.
11. NEVER vent flue gases into another room, a fireplace or any space inside a building. This could cause property damage, bodily injury or death.
12. Never test for gas teaks with an open flame. Use a soap solution to check all gas connections. This will avoid the possibility of fire or explosion.
13. ALLOW the furnace to cool before servicing. Always shut off electricity and gas to furnace when working on it. This will prevent any electrical shocks or burns.
14. DUE TO HIGH TEMPERATURES, locate the furnace out of traffic and away from furniture and draperies.
15. ALERT children and adults to the hazards of high surface temperatures and warn them to keep away to avoid burns or clothing ignition.
16. CAREFULLY supervise young children when they are in the same room with the furnace.
17. DO NOT place clothing or other flammable material on or near furnace.
18. INSTALLATION and REPAIR must be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passages be kept clean.
19. BEFORE INSTALLING: To avoid electrical shock, tum off electrical circuits that pass through the wall where you are going to install the furnace.
20. BE AWARE of good safety practices by wearing personal protective equipment such as gloves and safety glasses to avoid being injured by sharp metal edges in or around furnace and while cutting or drilling holes in wood and/or sheet metal.
21. CAUTION: Label all wires prior to disconnection when servicing controls.
WARNING: Do not use this furnace if any part has been under water. Immediately call a certified service technician to inspect the furnace and to replace any part of the control system and any gas control which has been under water.
WARNING: Do not install any of these furnaces
(Natural or L.P. Gas) in mobile homes, trucks or recreational vehicles.
Introduction
– 5
Introduction
Basic Description
The following steps are all needed for proper installation and safe operation of your furnace. If you have any doubts as to any requirements, check with local authorities. Obtain professional help where needed. All of the checks and adjustments in the “Start-Up Procedures” are vital to the proper and safe operation of your furnace. Please read our instructions before you install and use your furnace. This will help you obtain the full value from this furnace. It could also help you avoid needless service costs if the answer to the problem is found within this instruction manual.
Always consult your local heating or plumbing inspector, building department or gas utility company regarding regulations, codes or ordinances which apply to the installation of a counterflow top vented wall furnace.
Check the furnace nameplate, located in the burner compartment, to make sure the furnace is equipped to operate on the type of gas available (either natural or L.P. gas).
Tools Needed
DO NOT convert the furnace from natural gas to L.P. gas or from
L.P. gas to natural gas without the proper manufacturer’s gas conversion kit.
Your Counterflow Top Vent Furnace draws air in at the top of the furnace by the fan and discharged through the grille near the floor.
It is shipped ready to install on the surface of a wall or recessed into a wall. Combustion air is drawn in from the room where the furnace is located and vented out the top of the furnace through listed vent piping to a roof top vent. Venting material is not supplied with this furnace.
This appliance is equipped with a vent safety shutoff system designed to protect against improper venting of combustion products. Operation of this wall furnace when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide
(CO) poisoning and possible death.
Hand drill or properly grounded electric drill
Expansion bit 1/2" to 1-5/8" or 1/2'' and 1-1/2" blade bits
1/8" and 3/16" drill bit (metal)
6 ft. folding rule or tape measure
Screwdriver (med. blade)
Screwdrivers (Phillips Head)
Pliers (wire cutting)
Hammers
Materials
Pipe and fittings to make connections to furnace (See page 18).
Caulking compound-silicone rubber with a temperature rating of
500
F.
DO NOT use caulking compound advertised as paintable or for bath tub use as most contain fillers and will not withstand high temperatures.
Pipe Joint Compound resistant to L.P. gases.
Electrical wiring supplied as needed (see page 19). Minimum wire size is #14 gauge copper.
Hole Saw - 2"
Hack Saw
Stud locator or small finishing nails.
Tin snips
8 and 12" adjustable wrenches
Keyhole or sabre saw
2 - 10" or 12" pipe wrenches
Gloves and safety glasses
Trim Accessory 4701 is recommended or 3/4” Quarter Round or other wood trim molding approximately 16’long.
Oval Vent Kit 9901 is recommended.
Vent Enclosure Kit 9812 or 9824 if furnace is to be surface mounted is recommended.
1 x 1 wood strips if Optional Side Outlet Grille Register
6701 is used.
Helpful Installation Information
The following booklets will help you in making the installation:
ANSI/NFPA 70-1990 or current edition "National Electrical Code". In Canada: CSA C22.1 Canadian Electrical Code.
American National Standard NFPAS4/ANSI Z223.1 1988 or current edition "National Fuel Gas Code".
Obtained from: American National Standards Institute, Inc., 1430 Broadway, New York, N Y 10018.
In Canada: CAN/CGA B149.
6
Introduction
Optional Accessories
DIFFUSER GRILLE KITS 6703 & 6704
Let’s you route some heated air in a two-way direction. Kit 6704 for one-way direction.
SIDE OUTLET GRILLE KIT 6702
REAR OUTLET KITS 6801 & 6802
Let’s you route some heated air into a second room behind the furnace. Finished wall of second room must be within 10 inches of furnace as shown on Page 8, Fig. D. Built-in damper lets you shut off air flow to second room if desired.
Unpack Your Furnace
OVAL VENT KIT 9901
This U.L. listed B/W vent kit contains 4 feet of oval double walled vent pipe, plate spacers and starter or hold-down plate that starts the venting from the top of the furnace. See page 16 for additional items you will need.
VENT ENCLOSURE KITS 9812 or 9824
Allows you to direct heated air from the side of furnace into the same room.
OUTLET GRILLE REGISTER 6701
Let’s you route some heated air into a second room. Mounts on the side wall of second room and must be within 10 inches of wall furnace.
These kits are used only when the furnace is surface mounted.
They enclose the vent pipe from the top of the surface to the ceiling.
TRIM STRIP KIT 4701
Provides finished edge at sides of wall furnace. Neutral beige enamel painted steel.
The furnace is shipped in one carton containing the furnace, installation instruction booklet and hardware bag.
1. Lay carton horizontally. Open carton and remove top trim cover from its packing. Remove thumb screw at top of furnace, raise top front panel ½ inch and remove panel from cabinet. This is so you can get to the electrical connections later.
2. Place these and other parts, as they are removed from furnace, where they cannot be lost or damaged before you need them.
3. Bottom front panel can be removed by grasping just below handle and pulling it outward and then upward. See Fig. 1.
NOTE
Check the burner rating plate, located in burner compartment, to make sure your furnace is equipped to operate on the type of gas available (either Natural or L.P. Gas). Do NOT convert unit from
Natural Gas to L.P. Gas or from L.P. Gas to Natural
4. Remove all literature and package containing thermostat, wire and metal anchors used for free standing installation.
5. Check the fan blade to be sure it spins freely.
FIGURE 1
Installing Your Furnace
The following steps are needed for proper installation and safe operation of your furnace. If you have any doubts as to any requirements, always consult your local Heating or Plumbing lnspector, Building Department or Gas Utility Company regarding regulations, codes, or ordinances which apply to the installation of a vented wall furnace. Obtain professional help where needed.
1. Locate the furnace properly within the space to be heated.
2. Install the furnace in accordance with local codes or ordinances and instructions provided. In the absence of local codes or ordinances, install the furnace to conform with the current edition of the National Fuel Gas Code, NFPA 54, ANSI
Z223.1/Canadian Installation Code, CAN/CGA B149.
The CHECK AND ADJUSTMENTS on page 24 are vital to the proper and safe operation of the furnace. Be sure they are done.
3. Maintain minimum clearance: Floor 0 inches or ceiling 2 inches, side wall 4 inches. For exception to minimum side wall clearance, as shown on Page 8, Fig. 3.
IMPORTANT 4. Provide enough combustion and ventilation air.
For satisfactory and trouble-free operation, be sure to:
Locating Wall Furnace & Thermostat
Consider the following points before attempting to install the furnace:
CAUTION: Do not make cut-outs in the wall or ceiling before checking in the attic for ceiling joist locations and proposed venting.
With standard furnace discharge outlet, do not install closer than 4 inches to intersecting wall. See figure as shown on Page 8, Fig.
3B.
When using optional kits 6703 or 6704 maintain clearances as shown on Page 8, Fig. 3A or 3C.
When using optional kit 6704 maintain clearance as shown in
Figs. 3A and 3F, page 8. Use only optional outlet and grille kits available from manufacturer.
The counterflow vented wall furnaces are shipped ready to install on the surface of the wall or recessed up to 9-1/4 inches into the wall, with studs 16 inches center-to-center or stud space can be framed to 16 inches, see page 11, Recessed Mounting.
Place the furnace near the center of the space to be heated for good air circulation. Do not put it behind a door or draperies.
Do not instatl the furnace in a closet, alcove, of small hallway where the furnace could be isolated by closing doors to the heater space.
FIGURE 2 Minimum Clearances
Do not install the furnace in a mobile home, trailer, or recreational vehicle.
The bottom of the furnace may rest directly on a wood or concrete floor, If floor is other than wood or concrete there must be a piece of wood or sheet metal under the furnace that is at teast the same size as the bottom of the furnace.
On recessed installations the recessed portion rnay have 0 inches clearance to combustible material.
To provide adequate clearance and service access the front of the furnace must face the open room. Be sure that gas piping and electrical wiring can be brought to the location. See sections covering piping and electrical wiring for your type of furnace mounting.
Furnace vent must be installed directly to the outdoors so that combustion gases will not collect inside the building.
Provide an adequate vent or flue in accordance with local codes or ordinances and instructions provided by the vent pipe manufacturer.
Check the minimum spacing needs as shown on Page 7, Fig. 2 and Page 8, Fig. 3.
The top of the furnace must be at least 4 inches from the ceiling.
See Fig. 2.
8
Installing Your Furnace
FIGURE 3 Minimum Clearances
With standard furnace discharge outlet, do not install closer than 4 inches to intersecting wall.
Choose a location for the thermostat about 5 feet above the floor on an inside wall. The thermostat wire supplied with your furnace is 20 feet long, which should be enough to run up through the attic so the thermostat can be a maximum of 16 feet from the furnace measured in a straight line, or approximately 12 feet from the furnace if the wire is run under the floor. The thermostat should be sensing average room temperature, avoid the following:
HOT SPOTS:
Concealed pipes or ducts
Fireplaces
Registers
TV sets
Radios
Lamps
Direct sunlight
Kitchen
COLDSPOTS:
Concealed pipes or ducts
Stairwells – drafts
Doors
– drafts
Unheated rooms on other side of wall
DEAD SPOTS
Behind doors
Corners, and alcoves
After picking a location that meets the requirements, check the walls, attic and roof to make sure there are no obstructions such as pipes, electric wiring, etc., which could interfere with the installation of the furnace or vent pipe. If required, move them or pick a new location.
WARNING: Danger of property damage, bodily injury or loss of life. Do not install furnace in any area where oxygen is in use.
Combustion & Ventilation Air
WARNING: Danger of property damage, bodily injury or loss of life. The furnace and any other fuel- burning appliances must be provided with enough fresh air for proper combustion and ventilation of flue gases. Most homes will require that outside air be supplied into the heated area.
The high cost of energy for home heating has brought about new materials and methods used to construct or remodel most current homes. The improved construction and additional insulation has reduced the heat loss and made these homes much tighter around windows and doors so that infiltrated air is minimal. This creates a problem to supply combustion and ventilation air for gas-fired or other fuel burning appliances. Any use of appliances that pull air out of the house (clothes dryers, exhaust fans, fireplaces, etc.) increases this problem and appliances could be starving for air.
In addition, these energy measures mean that your home will retain more water vapor or a higher relative humidity.
High humidity, especially during cold weather, may be damaging to buildings because condensation forms on windows and inside walls.
The combination of a tight energy efficient home with the use of exhaust fans, fireplaces, clothes dryers, and gas appliances result in more and more air being drawn from the house until fresh air may be sucked back into the house down a furnace flue or fireplace chimney. Carbon monoxide can be the result. Carbon monoxide (CO) is a colorless, odorless gas produced when fuel is not burned completely or when the flame does not receive sufficient oxygen. Automobiles, charcoal, wood fires and improperly vented or air-starved coal, oil and gas furnaces or other appliances can produce carbon monoxide.
Be aware of these air-starvation signals:
1. Headaches, nausea, dizziness.
2. Excessive humidity shown by heavily frosted windows or a moist "clammy" sensation.
3. Fireplace smoke fills the room or will not draw.
4. Furnace flue backs up.
Installing Your Furnace
AIR REQUIREMENTS
The requirements for providing air for combustion and ventilation are listed in the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in
Canada: CAN/CGA B149). Most homes will require that outside air be supplied to the heated area by means of ventilation grilles or ducts connecting directly to the outside or spaces open to the outdoors such as attic or crawl space. The only exception is when the furnace area meets the requirements and definitions for an unconfined space with adequate air infiltration.
WARNING: Danger of property damage, bodily injury or loss of life. The furnace and any other fuel- burning appliances must be provided with enough fresh air for proper combustion and ventilation of flue gases. Most homes will require that outside air be supplied into the heated area.
All air openings and connecting ducts must comply with the following:
If the furnace is installed in an area with another gas appliance(s), the total input rating of all appliances must be considered when determining the free area requirements for combustion and ventilation air openings.
Ducts must have the same cross-sectional area as the free area of the openings to which they connect. The minimum dimension of rectangular air ducts must not be less than 3-inches in length or height.
FIGURE 4 Draft Hood Spillage
2. Turn on all exhausting devices, such as:
kitchen and bathroom exhaust
dryers (gas and electric) fans
3. Turn on all vented gas appliances, such as:
heating equipment including any room heaters,
water heater/stoves.
4. Wait ten (10) minutes for drafts to stabilize.
5. Check for draft hood spillage at each appliance. (Hold a lighted match 2 inches from draft opening. See Fig. 4.)
B. No Spillage
If the match flame pulls toward draft hood - this indicates sufficient infiltration air:
1. Return exhausting devices and appliances to the condition you found them.
LOUVERS / GRILLES AND SCREENS COVERING
FREE AREA OPENINGS
If a screen is used to cover the opening(s), it must not be smaller than 1/4-inch mesh. Use the free area of a louver or grille to determine the size opening required to provide the free area specified. If the free area is not known, assume a 20% free area for wood and a 60% free area for metal louvers or grilles.
EXAMPLE 1
FURNACE LOCATED IN UNCONFINED SPACE.
An unconfined space must have a volume of a minimum 50 cubic feet per 1000 Btu/hr. of total of all appliances in area. Adjoining rooms may be included only if there are no doors between the rooms, or if special provisions are made such as ventilation grilles installed between connecting rooms.
C. Draft Hood Spills
If there is spillage at a draft hood (match goes out or flame wavers away from draft hood):
1. Check for plugged flue connectors and chimneys. Check and repair, stoppage and test again.
2. If you have a fireplace, open a window or door near the fireplace and then check for spillage. a) If spillage stops, do not use the fireplace without a nearby window or door open until you can supply fresh air by a permanent duct.
3. If you have kitchen and bathroom exhaust fans, turn them off and check for spillage. a) If spillage stops, do not use exhaust fans until you can supply fresh air by a permanent duct.
Page 10, Fig 6 shows the minimum area in square feet' based on
8 foot ceiling heights, required for different Btu/hr. input ratings.
A. If your furnace is in an open area (unconfined space*) the air that leaks through the cracks around doors and windows may be enough for combustion and ventilation air. The doors should not fit tight. The cracks around windows should not be caulked or weather stripped.
To determine if infiltration air is adequate, perform following checks:
1. Close all doors and windows. If you have a fireplace, start a fire and wait until flames are burning vigorously.
WARNING: Danger of property damage, bodily injury or loss of life. Draft hood spillage, with unobstructed vents, indicates that additional air must be brought into the structure from outside.
Keep a window open (minimum 2 inches) near the appliance until a permanent air duct is installed.
Installing Your Furnace
4. Spillage means air starvation and a fresh air duct or air intakes must be installed to provide air directly to the furnace or other gas appliance.
D. If spillage exists or when the furnace is in a building of tight construction where the windows and doors are weatherstripped, air for combustion and ventilation must be obtained from outdoors or space open to the outdoors. within 12 inches of the bottom of the room connecting directly to unconfined space. Each opening must have a free area of at least
100 square inches or 1 square inch per 1000 Btu/hr. combined input of appliances in one room if combined input exceeds
100,000 Btu/hr.
Provide an opening(s) having a total free area of 1-square inch per 4000 Btu/hr. for the total of all appliances. The required area is shown on page 11, Fig. 9.
FIGURE 5 Fresh Air duct
WARNING: Danger of property damage, bodily injury or loss of life. The adjoining unconfined space must have adequate air infiltration as defined in example 1.
FOR EXAMPLE: Your furnace is rated at 50,000 Btu/hr. The water heater is rated at 30,000 Btu/hr. The total is 80,000 Btu/hr. You need two grilles, each with 100 square inches of free opening.
Metal grilles have about 60% free area, so you need two metal grilles each with 160 square inches of louvered area.
4,000 Btu/hr. Per
Btu/hr.
Fig 5 shows a typical duct going into ventilated crawl space or attic.
1. Duct must terminate at a point not more than 1 foot above the floor.
2. Duct size must be at least 1 inch of free area for each
4000 Btu/hr. of input of all appliances in area.
EXAMPLE 2.
Refer to figure as shown on Page 11, Fig. 7, which shows grille installation. Using the previous example, the two connecting rooms plus the closet must equal at least 500 sq. feet to handle the combined input 50,000 plus 30,000.
B. All Air From Outdoors:
If confined space doesn't adjoin an unconfined space then air must be provided from outdoors or spaces open to outdoors such as attic or crawl space.
Provide two permanent openings, one within 12 inches of top, one within 12 inches of bottom of room connecting directly, or by using ducts, with the outdoors or areas open to outdoors.
FURNACE LOCATED IN CONFINED SPACE.
If furnace is installed in a confined space, it must be provided with free air for proper combustion and ventilation of flue gases by one of the following methods.
A. All Air From Inside Building:
If the confined space adjoins an unconfined space, provide two permanent openings, one within 12 inches of the top and one
If opening connects directly to, or within vertical ducts, the free area of each opening must be at least 1 square inch per 4,000
Btu/hr. combined input of appliances in area.
If horizontal ducts are used, the free area of each opening must be at least 1 square inch per 2,000 Btu/hr. combined input of appliances in area.
10
Installing Your Furnace
FIGURE 7 Grilles Connecting Rooms to
Make Unconfined space
FIGURE 8 Air from Outdoors or Crawl
Space
Openings for inlet or outlet air should not be made into attic area if attic is equipped with a thermostat controlled power vent.
FIGURE 9 Free Area
FOR EXAMPLE: Your furnace is rated at 50,000 Btu/hr. The water heater is rated at 30,000 Btu/hr. The total is 80,000 Btu/hr. You need two grilles, each with 20-square inches of free opening, unless connected by horizontal ducts which would require each grille or opening to have a free area of 40 square inches.
Btu/hr./Input
Btu/hr.
Recessed Mount Installation
FIND THE STUDS (See CAUTION on page 7)
Use a stud locator or small finishing nails. Repeatedly drive and remove a nail into the wall in the area of the stud until it is located.
Then find the inside edge of the stud. Leave the nail at this location.
The other stud should be about 14½-inches from the one found.
Drive finishing nails on the inside of this stud. Draw wall cutout to required size as shown on Page 13, Fig. 13. If wall studs are not on 16-inch centers see "CLOSE OFF STUD SPACE.
” (As shown on Page 13, Fig. 12).
CUT WALL OPENING
WARNING: BEFORE INSTALLING: To avoid electrical shock, turn off electrical circuits that pass through the wall where you are going to install the furnace.
ATTACH HEADER PLATE
MODELS: 5508231; 5508232; 6508631; 6508632
Locate header plate between wall studs at 88½-inches from finished floor and nail into position with end flanges pointing up.
Make sure header plate is level.
MODELS: 5008631; 5008632
Provide an opening as shown on Page 12, Fig. 10. Work from the top in the attic to cut away the ceiling plate.
Locate header plate between wall studs at 82½-inches from finished floor and nail into position with end flanges pointing up.
FIGURE 8 Air from outdoors or crawl space
Installing Your Furnace
MODELS: 3508231; 3508232; 3508631; 3508632
Locate header plate between wall studs at 74 inches from finished floor and nail into position with end flanges pointing up.
WARNING: Remove 4”x14” fiberglass gasket from bottom of header plate and discard. This gasket is not used when the furnace is recessed in the wall.
Locate and drill one (1) 1-1/2 inch hole at selected locations as shown on Page 12, Fig. 11 and Page 13, Fig. 13 or Page 14, Fig.
14.
Gas line can be run at this time or done after furnace is mounted, see section GAS SUPPLY AND PIPING, page 18.
FIGURE 11
FIGURE 10
GAS SUPPLY OPENING
A hole must be drilled for the gas line supply.
Decide whether the gas line will come through the floor or wall stud.
NOTE
If a pre-existing gas piping stub location is not compatible with hole or knock-out provided in furnace, you may make an alternate entry hole in the furnace back wall as shown on Page 14, Fig. 14.
CAUTION: Be careful not to damage any furnace components while making any alternate hole.
12
CLOSE OFF STUD SPACE (If Required)
If studs are not on 16 inch centers, cut the hole for the furnace next to an existing stud and frame in the other side using a 2 x 4 and spacer blocks as required. As shown on Page 13, Fig. 12.
ELECTRICAL SUPPLY ROUGH-IN
Run the electrical supply with the ground wire and thermostat cable into stud space next to furnace location.
Installing Your Furnace
FIGURE 12 Closed Off Stud Space (If
Required)
FIGURE 13 Knockout Dimensions
CAUTION: Do not run wire behind flanges of header plate or in any location where it might be damaged. Avoid splicing thermostat wire unless the spliced wires are properly cleaned, soldered and taped.
(1) MODELS : 5508231; 5508232
6508631; 6508632
(2) MODELS : 5008631; 5008632
(3) MODELS : 3508231; 3508232
3508631; 3508632
Surface Mount Installation
FIND THE STUDS AND CEILING JOISTS
(See CAUTION on page 7)
Find two studs at spot where furnace is to be placed. Use a stud indicator or small finishing nails. Repeatedly drive and remove a nail into the wall in the area of the stud until you find it. Then find one side. Leave the nail there. Drive another nail just on the other side of the same stud.
Inside edge of the other stud should be about 14-1/2 inches from the one found. Drive finishing nail on inside edge of this stud.
Using the nails as a guide, draw a line up both sides to the ceiling to locate hole cut out for vent pipe and electrical connections.
CUT CEILING OPENING
ELECTRICAL SUPPLY ROUGH-IN
The electrical supply openings must be made in the wall or floor below furnace to match holes in furnace bottom. See Fig. 13.
If desired, the power supply and thermostat cable can come into the wall stud space from a basement, crawl space or an adjoining stud space.
At selected location, drill a 1-inch hole for 115V power supply and a ½ inch hole for the thermostat cable.
Run wiring through the holes to the furnace leaving enough excess wire to make electrical connections after mounting furnace.
Mark off and cut 3-1/2 x 12 inch rectangular hole in ceiling, centered between wall studs. The back edge of the opening should be about 1/8 inch from the wall. As shown on Page 15, Fig.
16.
CAUTION: To avoid damage to wiring, be sure to route wire away from path of furnace vent.
GAS SUPPLY OPENING
A hole may need to be drilled for the gas line supply.
Decide whether the gas line will come through the floor or wall.
Installing Your Furnace
NOTE
If you decide to route gas line through right side of furnace, simply remove the knock-out provided in furnace side.
NOTES
If a pre-existing gas piping stub location is not compatible with hole or knock-out provided in furnace, you may make an alternate entry hole in furnace back wall per Fig. 14.
CAUTION: Be careful not to damage any furnace components while making any alternate hole.
Locate and drill one (1) 1-1/2 inch hole at selected location as shown on Page 12, Fig. 11; Page 13, Fig. 13, or Page 14, Fig 14.
Gas line can be run at this time or done after the furnace is mounted, see section CONNECTING GAS LINE.
General Vent Installation
The vent installation must comply with all local codes and ordinances. If in doubt, consult your local codes or inspector.
The furnace vent must be directed to the outdoors so that harmful combustion gases will not collect inside the building.
This furnace must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
Use U.L. listed B/W Vent Kit 9901. You must provide other items, not contained in the kit, necessary to complete your specific venting situation through the roof. Refer to typical venting system as shown on Page 16, Fig. 18.
Type B/W gas vent shall extend from the header plate of the vented wall furnace to a point above the highest ceiling plate within a stud space through which the vent passes, without any offsets or crossovers therein. After a type B/W gas vent passes through the highest ceiling plate within a stud space above the furnace which it serves, the vent system may be completed with a type B vent, of the same manufacturer, and offsets or break over, shall not be greater than 45 degrees from vertical. Maximum of two.
NOTE
The B/W vent must extend through the ceiling and roof terminating at least 12 feet above the finished floor on which the furnace rests.
First vent pipe offset (if required) is recommended not to be any closer than 2'-0" from header plate.
ATTACH HEADER & HOLD-DOWN PLATE
(SURFACE MOUNT)
Remove the fiberglass flue collar from the furnace flue extension.
This gasket is not used when the furnace is surface mounted.
Make sure that the 4 x 4 inch gasket is in position on the header plate.
Slide header plate over the furnace flue extension with the junction box entering the opening in top of furnace.
Refer to Fig. 15.
Fasten to matching holes in the furnace top through holes "A" in the header plate, using two (2) #8 x 3/8 inch screws provided.
Fasten the hold-down plate or starter plate to the top of the header plate using holes "B" in the header plate.
14
Installing Your Furnace
ALL MODELS
ATTACH HOLD-DOWN PLATE
(RECESSED MOUNT)
NOTE
Header plate should already be attached to wall studs. See
ATTACH HEADER PLATE, on Page 11 and 12.
Fasten hold-down plate to top of header plate using two (2) screws provided.
Nail the ceiling plate spacers either across or in between the cut out section of ceiling plate. If nailed between, ends must be bent at 90 degrees.
1/8” FROM WALL
INSTALL CEILING PLATE SPACERS
(SURFACE MOUNT)
Refer to Fig. 16.
Only one (1) plate spacer is required for surface mounting within a single story dwelling.
Cut 2 inches off each end of plate spacer.
Drill two (2) 3/16 inch holes in each end of plate spacer as shown in Fig. 16.
Fasten plate spacer to wall by nailing through one (1) drilled hole in each end, into the wall board and ceiling plate.
INSTALL CEILING PLATE SPACER
(RECESSED MOUNT)
Refer to Fig. 17.
Two ceiling plate spacers are in the B/W vent kit 9901. They must be fastened along each long edge of the ceiling hole to hold the oval vent pipe in the center of the hole.
INSTALL SURFACE VENT (SURFACE MOUNT)
NOTE
For surface mounting, it will be helpful to complete the gas piping supply to the furnace before installing the vent pipe. See section
GAS SUPPLY & PIPING, page 18.
Carefully move the furnace into position under the ceiling cutout.
Insert first lengths of oval, double wall vent pipe up through the ceiling cutout. Lower vent pipe to the hold-down plate. Push the vent pipe into the hold-down plate until it is completely seated.
(Hold-down cleats will engage the groove in the vent pipe.)
Secure hold-down plate to vent pipe using two (2) screws.
Using plumbers tape to secure vent to the plate spacer, nail through one (1) hole in each end of plate spacer, into the wall and ceiling plate.
INSTALL FURNACE VENT (RECESSED MOUNT)
Lower first lengths of oval, double wall vent pipe through the plate spacers to the hold-down plate.
Push the vent pipe into the hold-down plate until it is completely seated. (Hold-down cleat will engage the groove in the vent pipe.)
Secure hold-down plate to vent pipe using two (2) screws.
Installing Your Furnace
COMPLETE THE VENTING
Refer to Fig. 18.
Install oval to round adapter. Complete the piping extending it through the roof. Use 4" round, double wall (Type B) vent pipe, roof flashing, storm collar, and vent top as shown. The vent cap must be at least 2 feet higher than any point that is within 10 feet horizontally of the vent cap. There must be at least 1 inch clearance between the vent pipe and any combustible material.
IMPORTANT
Area above header within the stud space MUST be kept clear of any attic insulation to allow the free circulation of air around oval vent piping.
FIGURE 18 Typical Vent Installation
Mounting Your Furnace
To obtain adequate clearance for fastening furnace or to install gas supply fittings, it may be necessary to remove the burner and control assembly as follows:
Remove burner compartment door by pulling door top out and up.
Locate the air discharge shield. It is secured across the top of the burner control compartment. Remove two (2) screws and shield and set aside. Refer to the illustration on Page 32 #27A or 34 #21.
Disconnect wires to free control module from its mounting location. Mark or tag each wire removed for its exact reconnection. Refer to Page 17, Fig 19.
ALL OTHER MODELS
Disconnect two (2) 24 volt wires from the gas valve. Disconnect two (2) wire connectors from junction block midway on the thermocouple
DISCONNECT WIRING
MODELS: 3508231; 3508232; 5508231; 5508232
Remove the screws holding the ignition control unit and cover to the furnace casing.
REMOVE BURNER AND CONTROLS
MODELS: 3508231; 3508232; 3508631; 3508632
Locate the burner and screws that secure it. Remove the two (2) screws (one from each end). Lift one end of the burner at a time until free. Remove burner and controls from the compartment.
16
Installing Your Furnace
PART NUMBER P321900
ALL OTHER MODELS
Locate the burner and hex nuts that secure it. Remove the two (2) hex nuts (one from each end). Flip up the wire hinges. Lift one end of burner at a time until free. Remove burner and controls from the compartment.
POSITION FURNACE (RECESSED MOUNT ONLY)
NOTE
If your furnace is surface mounted, your mounting was started during VENT INSTALLATION, page 14. To complete furnace mounting, go on to FASTEN FURNACE BOTTOM on this page.
ALL MODELS
Make sure that the flue collar gasket, as shown on Page 16, Fig.
18, is in place over the flue extension. Check to see if header plate gaskets are in place.
Hold the furnace at a slight angle (top closer to the wall than bottom) with the flue extension centered under the oval hole in the header plate.
NOTE
Electrical wiring should already be routed to the header plate. If not, see sections on ELECTRICAL SUPPLY ROUGH-IN, page 12.
Place three (3) square gaskets over the junction box. See Page
16, Fig. 18.
ALL MODELS (RECESSED MOUNT)
Lift furnace up so that the flue extension enters the oval hole in the header plate. Straighten the furnace by pushing furnace bottom into the stud space.
IMPORTANT
AFTER FURNACE HAS BEEN PLACED IN POSITION, MAKE
SURE THE GASKETS ARE PRESSING AGAINST THE
FURNACE TOP TO ELIMINATE AIR LEAKS.
FASTEN FURNACE BOTTOM
(SURFACE AND RECESSED MOUNT)
NOTE
Fasteners are not furnished because of different requirements of various types of wall construction.
Fasten furnace to floor through holes provided in furnace bottom.
If you have concrete flooring, use an alternate fastening method.
See Fig. 20.
If burner and control assembly were removed, replace them by reversing "DISCONNECT WIRING" and "REMOVE BURNER
AND CONTROLS" sections on pages 16 and 17.
IMPORTANT
To prevent damage to wiring, make sure not to pinch the wires between furnace components. Keep them routed away from the burner.
Re-secure the air discharge shield across the top of the burner and controls compartment. Small leg of "L" shape must be positioned toward floor, pointing away from front of furnace. Refer to the illustration on Page 32 #27A or 34 #21.
FASTEN FURNACE TOP (SURFACE MOUNTING)
Fasten furnace top to wall using two (2) metal anchors (packed in plastic bag with thermostat) by placing them over the back flange of furnace top and screwing to wall. Refer to Page 17, Fig. 20.
FASTEN FURNACE TOP (RECESSED MOUNTING)
Fasten furnace top by drilling two (2) holes through the side flanges of furnace top and securing with two (2) screws or nails into the wall studs. Refer to Page 17, Fig. 20.
CAUTION: Be careful not to damage furnace components or wiring when drilling holes.
Installing Your Furnace
Gas Supply and Piping
Gas control valve, within the furnace, is shipped with a seal over the gas inlet tapping. Do not remove seal until ready to connect piping.
FIGURE 21
WARNING: Danger of property damage, bodily injury or death. Make sure the furnace is equipped to operate on the type of gas available. Models designated as natural gas are to be used with natural gas only. Furnace designated for use with liquefied petroleum (L.P.) gas rate orifices sized for commercially pure propane gas. They cannot be used with butane or a mixture of butane and propane.
GAS SUPPLY
For Natural gas, the minimum inlet gas supply pressure for the purpose of input adjustment is 5" water column. The Maximum inlet gas supply pressure is 7" water column.
For L.P. gas, the minimum inlet gas supply pressure for the purpose of input adjustment is 11" water column. The maximum inlet gas supply pressure is 13" water column.
Gas pressure and input to the burners must not exceed the rated input and pressure shown on the rating plate. On Natural Gas the manifold pressure should be 4 inches water column. The manifold pressure should be 10.5 inches water column for L.P. Gas. See page 21 for operation above 2,000 feet altitude. Orifice change may be required to suit gas supplied. Check with your local gas supplier.
ORIFICE SIZES
Furnace Technical Information, page 25, shows the correct orifice sizes for the different input ratings when using Natural or L.P. Gas.
GAS PIPING
The gas supply line must be of adequate size to handle the Btu/hr. requirements and length of the run for the unit being installed.
Determine the minimum pipe size from Page 19, Fig. 23, basing the length of the run from the gas meter or source to the unit.
FIGURE 22
– Proper Piping Practice
All piping must comply with local codes and ordinances or with the
National Fuel Gas Code (ANSI Z223.1), whichever applies. In
Canada: Follow CAN 1-B149 Installation Code.
Refer to Page 18, Fig. 21, for the general layout at the unit. It shows the basic fittings needed.
18
Installing Your Furnace
The following rules apply:
1. Use new, properly reamed pipe free from metal chips and debris such as steel or black iron pipe. Use fittings approved by local codes.
2. Do not thread pipe too far. Valve distortion or malfunction may result from excess pipe within control. Apply moderate amount of good quality dope to pipe only, leaving 2 end threads bare.
If LP Gas installation, use compound resistant to action of liquefied petroleum gases.
3. Use ground joint unions.
4. Install a drip leg to trap dirt and moisture before it can enter the gas valve. Drip leg must be a minimum of 3 inches long.
5. Install a manual shut-off valve.
6. Provide a 1/8" NPT test gauge connection immediately before the gas supply connection to the furnace. disconnected during testing. (SEE WARNING.) Apply soap solution to each joint. Bubbles forming indicate a leak. Correct even the slightest leak at once.
FIGURE 23 Gas Pipe Sizes
Btu/hr.
Btu/hr.
GAS CONNECTION
If installation is for L.P. Gas, have L.P. installer use two-stage regulation and make all connections from storage tank to furnace.
Use two pipe wrenches when making the connection to the valve to prevent turning or damage to gas valve.
Connections between the manual shutoff valve and burner control assembly can be made with an A.G.A./C.G.A. design certified flexible connector if allowed by local codes. Drip leg and ground joint unions are still required.
Tighten all joints securely.
CHECKING THE GAS PIPING
Test all piping for leaks. When checking gas piping to the furnace with gas pressure less than 1/2 PSI, shut off manual gas valve to the furnace. If gas piping is to be checked with the pressure at or above 1/2 PSI, the furnace and manual shut off valve must be
Electrical Wiring
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code (ANSI/NFPA 70) or Canadian
Electrical Code (CSA C22.1), if an external electrical source is utilized. This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
Do not cut or remove the grounding prong from this plug.
ELECTRICAL SUPPLY
Remove three-prong (grounding) service cord from the envelope parts package to install in the furnace. Remove 7/8" diameter
(22mm) knockout at the left or right bottom side panel to route the three-prong service cord to an electrical outlet.
1. Insert the nylon cap attached to the end of the three-prong service cord thru the 7/8" diameter (22mm) knockout into the burner control assembly area and insert it into the nylon plug attached to the outer casing bottom. If desired, you may route the thermostat wire alongside of the service cord and thru the same opening or choose another entry into the burner control assembly area.
2. Attach 7/8" diameter (22mm) strain relief around the threeprong (grounding) service cord and the thermostat wire (if thermostat wire is routed thru knock-out). Insert the 7/8"
(22mm) strain relief into the 7/8" (22mm) hole in the side panel of furnace.
WARNING: Danger of property damage, bodily injury or loss of life. Never use a match or open flame to test for leaks. Never exceed specified pressures for testing. High pressures may damage the gas valve and cause over-firing which may result in heat exchanger failure. Liquid petroleum
(L.P. Gas) is heavier than air and it will settle in any low area, including open depressions and it will remain there unless area is ventilated.
Never attempt startup of unit before thoroughly ventilating area.
WARNING: Do not insert the three-prong
(grounding) service cord inside the burner control assembly area more than 10 inches (245mm). This could cause damage to the electrical cord resulting in electrical shock hazard and/or fire.
LOW VOLTAGE CONNECTIONS
CAUTION: The Heat Anticipator will burnout if 24 volts are applied directly to thermostat by shorting out the gas valve or primary control during testing or by incorrect wiring.
WALL THEMOSTAT WIRING
Run thermostat wire to the furnace. Connect thermostat to two wires marked "Thermostat" extending from top of furnace, using two wire nuts provided. See Wiling Diagrams on pages 30 or 31.
Replace fan to original position on motor shaft, tightening securely. Replace fan shroud, making sure it is centered vertically on the fan.
Tighten screws securely.
Replace top front panel and secure with thumbscrew.
COMPLETE WIRING DIAGRAMS ON PAGES 30 AND 31.
20
Installing Your Furnace
Thermostat Installation
1. If an old thermostat is being replaced and is in a satisfactory location and the wiring appears to be in good condition, use existing wiring. If in doubt, use new wire.
FIGURE 24 Route Thermostat Cable
2. If a new location is chosen or if this is a new installation, thermostat cable must first be run to the location selected. All wiring must agree with local codes and ordinances. These instructions cover bringing the wire down from the attic but it can be run from a basement or crawl space using similar methods. Refer to Fig. 24.
3. Before drilling a hole in the wall at selected location, drive a small finishing nail through the ceiling in the corner of the wall and ceiling above the thermostat location. Pull the nail out and push a small stiff wire through the hole so it can be found in the attic. Drill a 1/2 inch hole through the ceiling wall plate.
4. Probe for obstructions in the partition. Then drill a 1/2 inch hole through wall at the selected location for thermostat.
5. From the attic, feed the thermostat cable or a stiff wire through wall until even with thermostat location.
6. Snag thermostat cable through hole and pull cable through hole in wall so that 6 inches of cable protrudes.
7. Route cable to wall furnace.
MOUNTING THE THERMOSTAT
1. To remove thermostat cover, squeeze both sides and lift.
Carefully remove and discard the packing tab protecting the switch contacts See. Fig 25.
2. Connect the thermostat wires to the terminal screws on the thermostat base.
3. Push any excess wire back through hole in wall and plug hole with insulation to prevent drafts from affecting thermostat operation.
4. Being sure to level the thermostat for best appearance, fasten the thermostat base to the wall through mounting holes with screws provided.
5. Replace the thermostat cover.
FIGURE 25 Thermostat
SQUEEZE FIRMLY
BOTH SIDES AND LIFT
TO REMOVE COVER
NOTE: Use heavier wire size if more than 20 ft. of wire is required.
Installing Your Furnace
Start-Up Procedure
Start the furnace using the procedures in section OPERATING
YOUR FURNACE.
WARNING: Danger of bodily injury or death.
Liquefied petroleum L.P. Gas is heavier than air and it will settle in any low area, including open depressions and it will remain there unless the area is ventilated.
Never attempt start-up of unit before thoroughly ventilating area.
Check the furnace operation as outlined in the following instructions. If any sparking, odors or unusual noises are encountered, shut off electric power immediately. Recheck for wiring errors or obstructions in or near fan motor.
WARNING: Natural gas heating value (Btu per cubic foot) can vary significantly. Therefore, it is the installer's responsibility to see that Btu/hr. input to the furnace is adjusted properly. Failure to do so could cause combustion chamber failure, asphyxiation, fire or explosion resulting in damage, bodily injury or death. Refer to the National Fuel
Gas Code (NFPA 54) to be sure the furnace is burning fuel at the proper rate.
Under firing could cause inadequate heat, excessive condensation or ignition problems. Over firing could cause sooting flame impingement or overheating of the heat exchanger.
Before starting natural gas input check, obtain heating value of gas (BTU per cubic foot) at standard conditions from your local supplier. This factor is used in "Check the Gas Input" section and procedure.
CHECK THE MANIFOLD GAS PRESSURE
A tapped opening is provided in the gas valve to facilitate measuring the manifold gas pressure. A "U Tube" manometer having a scale range from 0 to 12-inches of water should be used for this measurement. The manifold pressure must be measured with the burner and pilot operating. Any major changes in flow must be made by changing the size of the burner orifice.
Check with your local gas supplier for proper orifice sizing.
CHECK THE GAS INPUT (NATURAL GAS ONLY)
To measure the input, using the gas meter, proceed as follows:
1. Turn off gas supply to all other appliances except the furnace.
2. With the furnace operating, time the smallest dial on the meter for one complete revolution. If this is a 2-cubic-foot dial, divide the seconds by 2. If it is a 1-cubic-foot dial, use the time in seconds as is. This gives the seconds per cubic foot of gas being delivered to the furnace.
3. Assuming natural gas with a heating value of 1,000 Btu per cubic foot and 34-seconds per cubic foot used as determined by step (2), then:
Seconds per hour = 3,600
Input = 1,000 x 3,600 / 34 = 106,000 Btu/hr.
This measured input must not be greater than the input indicated on the nameplate of the furnace.
4. Relight all other appliances turned off in Step 1 above. Be sure all pilots are operating.
ADJUST PILOT BURNER (STANDING PILOT MODELS ONLY)
PiIot fIame should surround 3/8 inch to 1/2 inch of the thermocouple tip. To adjust, remove pilot adjustment screw on gas valve. Turn screw counterclockwise to increase flame, clockwise to decrease. Replace cap.
CHECK GAS INPUT AND PRESSURES
For furnaces located at elevations between sea level and 2,000 feet, the measured input must not be greater than the input shown on the rating plate of the furnace. For elevations above 2,000 feet, the measured input must not exceed the input on the rating plate reduced by 4 percent for each 1,000 feet that the furnace is above sea level.
Gas supply pressure and manifold pressure with the burners operating must also be as specified on the rating plate.
Type of Gas Manifold Pressure, In. W.C.
Natural 4.0
L.P. 10.0
Rated input will be obtained on a heating value of 2,500 Btu/hr. for propane at 10 inches manifold pressure with factory-sized orifices.
If L.P. Gas having a different heating value is supplied, orifices must be changed by a qualified service technician before the furnace is operated.
CHECK THERMOSTAT
Check thermostat operation. When set above room temperature shown on the thermostat, the main burner should light. Make certain the thermostat turns off the furnace when the room temperature reaches the selected setting and starts the furnace when room temperature falls a few degrees.
FIGURE 26 Thermostat
INDICATOR
LOWEST
SETTING
22
Operating Your Furnace
Operating Your Furnace
STANDING PILOT MODELS
3508631; 3508632; 5008631; 5008632; 6508631; 6508632
NOTE:
For models equipped with WILLIAMS gas valve P323209 or
P322042 refer to this page and page 23 for "SAFETY &
LIGHTING INSTRUCTION" and "TURN GAS OFF TO
APPLIANCE."
On new installations, the gas lines will be filled with air and it may take several minutes to establish the pilot flame.
Keep all access doors and panels in place except for inspection and maintenance.
WARNING: operation. Keep children, clothing, furniture, and flammable material away from it.
Do not store or use gasoline or other flammable liquids or vapors near the furnace.
SAFETY CONTROLS
These furnace are protected against unsafe operation by five automatic safety controls: (1) A safety pilot acts to shut OFF the gas valve in case of pilot failure; (2) A redundant gas valve; (3) A limit switch shuts down the main burner to prevent overheating the furnace cabinet; (4) A vent safety shutoff device shuts down the main burner to protect against improper venting of combustion products. These limit switches will reset when furnace cools; and
(5) A thermal overload protects the motor against burnout caused by current surges or if anything should block the flow of air through the furnace. This switch will reset itself when the motor cools down and it cannot be adjusted.
WARNING:
The surface of the furnace is hot during
Danger of ignition flash and eye injury or blindness.
Protect your eyes. Never attempt to light pilot with gas control valve knob in "on" position. Flashback could occur.
ELECTRONIC IGNITION MODELS*
3508231; 3508232; 5508231; 5508232
NOTE:
For models equipped with WILLIAMS gas valve P323209 or
P322042 refer to this page and page 23 for "SAFETY &
LIGHTING INSTRUCTION" and "TURN GAS OFF TO
APPLIANCE."
THE FURNACE WORKS LIKE THIS:
1. Thermostat turns on the control module.
2. Automatic relight system (in module) opens gas valve and electronically ignites pilot. After pilot flame has been established and proven by the control module, the main valve circuit opens and pilot lights main burners.
3. Heat builds up in the furnace and starts the fan. The heated air comes out the front bottom louvered panel at floor level.
4. When the thermostat setting is reached, it shuts off the main burner.
5. The fan runs until the heat is removed from furnace, then it turns off.
IMPORTANT
KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
SAFETY LIMIT CONTROL
These furnaces are protected against unsafe operation by three automatic safety controls: (1) The electronic ignition system; (2) A limit switch shuts down the main burner to prevent overheating the furnace cabinet; this limit switch will reset when furnace cools;
(3) A thermal overload protects the motor against burnout caused by current surges or if anything should block the flow of air through the furnace, the switch will turn the main burner off. When motor cools down, this switch will reset itself. This switch cannot be adjusted.
WARNING: Danger of ignition flash and eye injury or blindness. Protect your eyes. Never attempt to light pilot with gas control valve knob in "on" position. Flashback could occur.
NOTE:
Models 3508631; 3508632 are equipped with a single speed fan.
TWO-SPEED FAN OPERATION
MODELS: 5008631; 5008632; 6508631; 6508632
For models equipped with WILLIAMS gas valve P323209 or
P322042: Blower will first operate at low speed then shift to high speed as the furnace heats up.
IMPORTANT
KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
NOTE
Models 3508231; 3508232 are equipped with a single speed fan.
TWO-SPEED FAN OPERATION MODELS: 5508231; 5508232
Blower will first operate at low speed then shift to high speed as the furnace heats up.
WARNING: The surface of the furnace is hot during operation. Keep children, clothing, furniture, and flammable material away from it.
WARNING: Danger of property damage. Bodily injury or death
If the furnace overheats or fails to shut off, close manual gas valve for the furnace before turning off the electric power.
On new installations the gas lines will be filled with air and it may take several minutes to establish the pilot flame.
Keep all access doors and panels in place except for inspection and maintenance.
WARNING: Danger of property damage, bodily injury or death. If the furnace overheats or fails to shut off, close manual gas valve for the furnace before turning off electric power.
Care
– 23
Operating Your Furnace
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these Instructions exactly.
B. BEFORE LIGHTING smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance or strike a match.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
NOTE: FOR ADDITIONAL INFORMATION REFER TO THE
INSTALLATION AND OPERATION INSTRUCTION MANUAL
SUPPLIED WITH THIS APPLIANCE OR CONTACT THE
MANUFACTURER IDENTIFYING THE PRODUCT BY ITS MODEL
NUMBER LOCATED ON THE RATING PLATE, FOUND NEAR THE
GAS VALVE.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. Remove control access panel.
5. Turn gas control knob clockwise to "OFF".
9. Turn knob on gas control counterclockwise to
"PILOT."
6. Wait five (5) minutes to clear out any gas, then smell for gas, including near the floor. If you then smell gas, stop!
Follow "B" In the safety information above. If you don't smell gas, go to the next step.
7. Loosen wing nut and open pilot observation door (If equipped).
8. To find the pilot, follow the metal tube from gas control. The pilot is mounted on the side of the burner.
10. Push in the red reset button all the way and hold in.
Immediately light the pilot. Continue to hold the red reset button in for about (1) minute after the pilot is lit. Release button and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 10.
• If button does not pop up when released, stop and immediately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.
11. Close the pilot observation door and tighten wing nut (if equipped).
12. Turn gas control knob counterclockwise to "ON". The knob can be turned to "ON" only if red reset button is up.
13. Replace the control access panel.
14. Turn on all electric power to the appliance.
15. Set thermostat to the desired setting.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to be performed (if applicable).
3. Remove the control access panel.
4. Push in the gas control knob slightly and turn it clockwise to "OFF". Do not Force.
5. Replace the control access panel.
IMPORTANT: KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
WARNING: DUE TO HIGH SURFACE TEMPERATURES - KEEP CHILDREN, CLOTHING, FURNITURE
OR ANY COMBUSTIBLE MATERIAL AWAY FROM FURNACE.
FIGURE 39
Caring for Your Furnace
How To Care For Your Furnace
WARNING: Danger of bodily injury or death. Turn off electric power supply at the disconnect switch, fuse box or service panel before removing any doors or access or service panels from the unit.
CABINET FINISH
Clean the cabinet with damp rag. Never use abrasive cleaners.
Cabinets are finished in heat resistant powder coated finish - DO
NOT refinish with wall paint.
COMBUSTION AND VENTILATION AIR
The combustion and ventilation air supply must not be blocked.
Do not put anything in or on the furnace cabinet.
For better circulation and more effective heating, do not place obstructive furniture closer than four feet to the front of the cabinet or two feet to either side of the cabinet.
PILOT BURNER
Light pilot using instructions in OPERATING YOUR FURNACE
(on pages 22 and 23, depending on your model). Leave thermostat at lowest setting.
Pilot flame should surround 3/8 to 1/2 inch of the thermocouple tip. Refer to Fig. 28, Page 25. If flame needs adjusting, do it as follows:
ADJUST PILOT BURNER (Page 25 Fig 28)
1. Remove screw cover over pilot adjusting screw.
2. Insert small screwdriver, adjust flame as needed. Turn screw counterclockwise to increase flame, clockwise to decrease.
3. Turn thermostat to highest setting. Main burners should light quickly and smoothly. Turn thermostat to lowest setting. Main burners should go out. Pilot should remain lit except for electronic ignition models. See Page 23.
BURNER FLAME
FURNACE AREA
Keep the area near the furnace clear and free from combustible materials, gasoline, and other flammable liquids and vapors.
ANNUAL UPKEEP NEEDED
Start the furnace and let it operate about 10 minutes then look at the burner flame. Flames should be soft and blue, see Fig. 28. If flames appear abnormal, contact the gas company or a qualified service technician immediately.
It is recommended that a qualified service technician perform these checks at the beginning of each heating season.
CLEANING AND OILING
Shut off electricity, and then remove cabinet door and front panel.
Clean any lint or dirt from fan blades, fan motor, and exposed air passages. Use a brush.
Put 5 drops of SAE 20 oil in each of the two cups or oil tubes on the fan motor, See Fig. 36, below.
FIGURE 27
VENTING SYSTEM
Make sure that no parts of the vent air system are blocked or rusted. Clean or replace before using furnace.
24
Care
– 25
Caring for Your Furnace
How To Care For Your Furnace
BURNER CLEANING
Check burner. If cleaning is required, contact a qualified service technician to clean and service burner.
WARNING: Danger of bodily injury or death. Make sure electric power and gas supply are off before removing panels or doors, etc.
TO REMOVE BURNER(S)
Disconnect gas line inside cabinet.
Refer to "Mounting Your Furnace" section (pages 16 and 17).
FIGURE 28 Pilot Flame & Spark Gap
CLEANING BURNER COMPARTMENT
Because cold air is attracted to the flame during furnace operation, a build up of lint from bedding and dust, etc., in the burner area will occur each heating season. It is necessary to clean this area regularly. Use a vacuum cleaner with a narrow attachment to reach small areas. Be careful in and around the pilot. A change in its adjustment could be made if struck during cleaning.
WARNING: A BUILDUP OF ANY DUST, LINT OR
FOREIGN MATERIAL IN THE PRIMARY AIR
OPENING OF THE BURNER CAN INTERFERE
WITH THE PROPER AIR GAS MIXTURE AND
GAN RESULT IN A YELLOW FLAME WHICH CAN
PRODUCE CARBON MONOXIDE AND SOOT.
THIS CONDITION, IF ALLOWED TO DEVELOP,
CAN LEAD TO BODILY INJURY INCLUDING
DEATH. IT IS IMPERATIVE THAT THE
BURNER(S) BE KEPT GLEAN.
Check the spark gap. It must be carefully adjusted to specifications, as illustrated (Fig. 28), for the ignition device to function properly.
Caring for Your Furnace
Furnace Technical information
Model Number
Furnace Technical Information
Main Burner Orifice
Gas Type
Input**
Rating Btu/hr.
DRILL DEC. QTY.
3508632 NATURAL
35,000
#36 .106
1
3508631 L.P.
35,000
#50 .070
1
3508232 NATURAL
35,000
#36 .106
1
3508231 L.P.
35,000
#50 .070
1
5008632 NATURAL
50,000
#42 .093
2
5008631 L.P.
50,000 N/A
.060
2
5508232 NATURAL
55,000 N/A
.094
2
5508231
6508632
L.P.
NATURAL
55,000
65,000
N/A
#36
.062
.106
2
2
6508631 L.P.
65,000
#51 .067
2
The efficiency rating of these appliances is a product of a thermal efficiency rating system determined under continuous operating conditions and was determined independently of any installed system.
**For elevations above 2,000 feet reduce ratings 4% for each 1,000 feet above sea level.
**Btu/hr. = British Thermal Units per hour.
26
Care
– 27
Troubleshooting
FOR MODELS: 3508631; 3508632; 5008631; 5008632; 6508631; 6508632
*Also applicable to Models equipped with an electric intermittent pilot system. (Continued on next page)
SYMPTOM
1. Pilot will not stay lit after following lighting instructions.
2. Main burner will not come ON - pilot burning and thermostat set for heat.
3. Burner comes "ON" but goes OFF before blower turns ON.
POSSIBLE CAUSE CORRECTIVE ACTION
A. Thermocouple producing insufficient millivolts.
Check pilot flame
– it must impinge on thermocouple. Pilot flame may be low or blowing (high) causing safety to drop out. Pilot orifice or aerating hole may be plugged
(check for spiders, webs or other organic material). Be sure the thermocouple is fully inserted in its bracket.
Clean and/or tighten the thermocouple fitting at the connection to the valve. B. Loose or dirty thermocouple connection at gas valve.
C. Thermocouple defective. Check thermocouple with millivolt meter
– it should generate approximately 30 millivolts when not connected to a load. When connected to a load, it should generate approximately 14 millivolts. If below 7 millivolts, replace.
Replace gas valve after above is checked out. D. Thermomagnet pilot safety defective
E. Vent safety shutoff device.
A. Gas valve not turned ON after lighting the pilot.
Check wiring connections from valve to the vent safety shutoff device. Be sure all connections are tight. Check for blocked or incorrect venting.
Turn gas valve knob to 'ON" position - if no main gas flow, proceed to Step. "B".
B. Electric power to furnace turned OFF.
C. Low voltage transformer or limit switch defective.
Check for line voltage at furnace - if okay and no main gas flow, proceed to Step "C".
D. Wall thermostat defective.
E. Burner orifice plugged.
F. Gas valve defective.
Check for 24 volts at the low voltage terminals of the transformer. If no voltage, turn
OFF electric power to furnace. Remove one wire from limit switch and check for continuity across both terminals. No continuity – replace limit switch. With a good limit switch back in the circuit and the electric power turned ON - if no voltage, replace transformer. NOTE: Before replacing the transformer or limit switch, check wiring for loose connections or broken wires and repair as needed. If voltage is present at transformer, proceed to Step "D".
With thermostat set for heat (contacts closed) check for voltage at terminals on gas valve. If no voltage is present replace defective thermostat. NOTE: Before replacing thermostat, be sure to check the wiring from the furnace to thermostat for loose connections or broken wires and replace as needed.
Clean or replace orifice - if okay and still no gas flow to main burners, proceed to Step
"F".
Replace defective gas valve.
A. Defective wiring.
B. Defective limit switch.
C. Defective motor (2speed).
D. Defective motor (1speed).
E. Detective fan switch.
A. Furnace not operating at full rate.
Turn OFF electric power to furnace. Remove top front panel, fan shroud and blower wheel. Refer to Wiring Diagram and check all wiring inside junction box. Remove center front panel and check all wiring inside switch box containing fan, limit and selector switches. Correct if necessary. If correct, proceed to Step "B".
NOTE: Selector switch used only on Models 5008731; 5008732; 6508731; 6508732.
If burner goes OFF in less than five minutes from room temperature start, check limit control switch. If detective, replace. NOTE: Blower should turn "ON" within three minutes after burner is "ON" from a room temperature start. If not, proceed to Step
"C ”.
Jumper across the fan switch, turn electric power ON, the motor should rotate. If a 2speed motor is used - jumper from "brown" terminal on the fan switch to #2 (red) terminal on the selector switch, motor should rotate on "LOW" speed. Jumper from same "brown" terminal on the fan switch to #3 (black) terminal on the selector switch, motor should rotate on "HIGH" speed. Replace motor if defective.
Jumper across fan switch, turn electric power ON, motor should rotate. Replace motor if detective.
If, after checking above possibilities, problem still exists, replace fan switch.
Check for low gas pressure at gas valve - should be 4" W.C. for Natural Gas, 11" W.C. for L.P. Gas. Check burner orifice.
4. Burner comes "ON", blower comes "ON", but cycles "ON" and "OFF" while burner remains "ON".
5. Burner comes "ON",
blower comes "ON", but burner cycles
"OFF" and "ON" with blower "ON".
A. Furnace operating overrate.
B. Line voltage too low.
C. Recirculation.
Check for high gas pressure at gas valve - correct if necessary. See correct pressure above.
Check line voltage to motor, if below 115 volts motor will run too slow.
Heated air discharging against an object causing recirculation, such as a hall installation or a large piece of furniture within 4' of discharge.
Check header plate installation and proper use of gaskets. Repair as necessary. D. Loss of circulating air due to leakage.
A. Thermostat location. 6. Furnace operates but turns "OFF" before
Check location of thermostat. It should not be in the path of warm air discharge from the furnace, near a lamp, or above a TV set or stereo.
Troubleshooting
SYMPTOM room temperature is attained.
7. Furnace operates but will not shut "OFF" when room temperature is attained.
POSSIBLE CAUSE
B. Defective thermostat.
A. Thermostat wiring defective.
B. Thermostat location.
C. Improper thermostat anticipator setting.
CORRECTIVE ACTION
Check thermostat calibration or replace.
Check thermostat wiring from furnace to thermostat - may be shorted together by a nail or staple.
Check thermostat location - if on an outside wall or there is a hole in wall behind the thermostat causing cold air to contact thermostat, relocate the thermostat.
Set anticipator per THERMOSTAT ANTICIPATOR, page 20.
8. Abnormal operation. A. Blower noise. Check motor mounts - they may be loose. Blower wheel could be out of balance. Set screw may be loose on motor shaft. Blower may be rubbing on fan shroud. Motor may need oiling. Correct as needed.
B. Expansion noise ticking. Check installation - casing may be twisted or not level at time of installation causing combustion chamber to bind on its locating pins.
C. Burner resonance.
D. Selector switch defective
(2-speed).
Usually associated with L.P. Gas operation. Adjust primary air screw in throat of each cast iron burner after about 10 minutes of operation. Adjust to obtain a soft blue flame without streaming yellow tips.
During normal furnace operation the motor will be on "LOW" speed when operating on minimum input capacity and on "HIGH" speed when operating at maximum input capacity. If there is no change in motor speed, replace selector switch.
FOR MODELS: 3508231; 3508232; 5508231; 5508232
*Also applicable to Models equipped with an electric intermittent pilot system. (Continued on next page)
SYMPTOM
1. No spark – no pilot gas.
2. Spark – but no pilot gas.
3. Pilot gas – but no spark.
POSSIBLE CAUSE
A. No main power.
B. Faulty transformer.
C. Faulty thermostat.
D. Faulty limit switch.
E. Faulty ignition control.
F. Faulty wiring.
G. Vent safety shutoff device.
A. Faulty ignition.
B. No gas supplied to pilot valve.
C. Manual valves in OFF position.
D. Faulty pilot valve.
E. Faulty wiring.
F. Restricted pilot line or clogged pilot orifice.
A. Faulty ignition control.
CORRECTIVE ACTION
Perform normal system checks of main power, transformer, thermostat, limit switch, and replace faulty component.
With power ON, turn thermostat to the lowest setting, wait for 10 seconds and return to
HIGH setting. With power ON and thermostat set at its highest position, set voltmeter to 24V scale and attach probes to terminals "TR" and "TH" on the ignition control unit.
If you read 24V and there still is no spark or pilot gas, the ignition control is defective and must be replaced.
Test wiring. Repair or replace.
Check wiring connections from valve to vent safety shutoff device, be sure all connections are tight. Check for blocked vent.
See 1E.
Check for availability of gas at gas control. Make sure the manual valve (gas cock) on the gas control are in the full ON position.
No pilot gas could be caused by plugged pilot tubing. Also check the pilot adjustment at the gas control.
See 1F.
See 2B.
With power ON, turn the thermostat to the lowest setting, wait for 10 seconds and then return it to the high setting. With power ON and thermostat set at its highest position, set voltmeter to 24V scale and attach probes to terminals "24V" (*TH) and "GRD"
(*TR) on the ignition control unit. If you read 24V and there is still no spark or pilot gas, the ignition control is defective and must be replaced.
With thermostat turned to its highest setting, set test meter to 24V scale.
Touch probes to "PV/MV" and "P\/" terminals on Gas Valve. If you do not get a
24V reading, check wiring. If wiring tests okay, check ignition control.
Connect probes to "PV/MV" AND "PV" terminals on ignition control. If you do not read 24V, the ignition control must be replaced.
28
Care
– 29
Troubleshooting
SYMPTOM
4. Pilot lit, but main burner won't come
ON.
5. Pilot cycles OFF and
ON by itself.
6. Main burner shuts down before thermostat is satisfied.
POSSIBLE CAUSE
B. Broken or shorted electrode assembly.
A. Faulty ignition control.
B. Faulty wiring.
C. Low pilot flame.
D. Improper alignment of sensor in pilot flame.
E. Faulty flame sensor.
CORRECTIVE ACTION
Remove wire at "PV/MV" terminal at the ignition control, being careful not to touch any metal parts; disconnect the electrode wire at the ignition control. Connect one end of a jumper wire to terminal "GND". (DO NOT REMOVE EXISTING WIRE.) Attach the other end of the jumper wire to the metal blade of a small screwdriver. Position end of metal blade approx. 1/8" from terminal. Reconnect "PV/MV" terminal. Sparking should occur between screwdriver blade and terminal.
If no sparking occurs, the ignition control must be replaced.
Check the pilot and electrode assembly for proper electrode gap (3/32" to 1/8") or any possible shorting of electrode to surrounding metal surfaces. Make sure the spark igniter and electrode connections to the ignition control are tight. The ignition control and pilot burner must both be chassis ground. If there is still no spark, the pilot and electrode assembly must be replaced.
See 3A.
See 1F.
NOTE: Wait at least 90 seconds after pilot lights before doing the check out procedures for problem number 4.
With thermostat ON, be sure that the pilot and sensor are properly aligned so that the pilot flame impinges the top 3/4 inch of the sensor. Be sure that the sensor is pushed all the way into pilot bracket. Adjust pilot flame with pilot adjustment, if necessary. Also check inlet supply pressure and pilot orifice. If pilot hood or sensor is bent, the defective unit should be replaced.
If main burner still won't come ON, make sure the main burner orifices are clear. If orifices are clear, set voltmeter to 24V scale and touch probes to the terminals of the main gas operator on the gas valve. Attach to terminal "MV", "PV/MV" on Gas Valve. If you read 24V and the burner won't turn ON, replace entire gas valve.
When main burner comes ON, ensure that the pilot flame is strong, sensor is properly aligned, and pilot flame impinges the top 3/4 inch of the sensor. (See procedures for check for proper pilot flame and alignment in problem 4c.) Check the pilot and electrode assembly for proper electrode gap (3/32" to 1/8") or any possible shorting of electrode to surrounding metal surfaces. Make sure the spark igniter and electrode connections to the ignition control are tight. The ignition control and pilot burner must both be chassis ground. If there is still no spark, the pilot and electrode assembly must be replaced.
BE SURE POWER IS "OFF" BEFORE PERFORMING THIS TEST!! Set test meter to
"ohm" scale or use continuity checker. Touch one end of probes to top of flame sensor, the other to "SENSE" terminal on the ignition control. Ohmmeter should read
"0", continuity should be evident. If you don't obtain a reading, remove wiring from sensor and test both individually. If continuity is not evident, replace wiring and/or sensor.
There should be NO continuity between sensor and "GND" terminal on the ignition control. Testing wiring and sensor individually, determine which is shorted on ground.
Replace or repair. Turn ON power.
See 2B.
See 1F.
See 4c.
See 4d.
A. Faulty pilot valve.
B. Faulty wiring.
A. Low pilot flame.
B. Improper alignment of sensor in pilot flame.
C. Pilot flame being drawn away from sensor.
D. Improper heat anticipator setting.
E. Faulty limit.
When main burner comes ON, ensure that the pilot flame is strong, sensor is properly aligned and pilot flame impinges the top 3/4 inch of the sensor. (See procedures for checking for proper pilot flame and alignment in problem 4d.) If the pilot flame is drawn away from the sensor when the main burner comes "ON" the cause could be the manual valve is not in the full ON position or the inlet gas pressure with the main burner ON. NOTE: Low inlet gas pressure to the gas control can be caused by several problems and is not within the scope of the procedures outlined in this service guide.
Consult your local utility or gas supplier.
See 6c.
Check the setting of the heat anticipator in the wall thermostat. Set it to setting specified on the gas control.
The system may be cycling on a faulty limit. Using a test meter set to the 110 volt scale, check for a voltage reading across the limit when the main burner shuts OFF. If you get a 24 volt or 110 volt reading on shutdown, replace defective limit switch.
Wiring Diagrams
Wiring Diagrams
MODELS - 3508231/3508232 MODELS - 5508231/5508232
30
Wiring Diagrams
MODELS - 3508631/3508632 MODELS - 5508231/5508232
FOR 55M B.T.U. FAN TYPE VENTED WALL
Accessories
– 31
32
Replacement Parts
3508231; 3508232; 3508631; 3508632
USE ONLY MANUFACTURER’S AUTHORIZED PARTS
FOR PARTS LIST SEE PAGES 36 AND 37.
27A
Replacement Parts
36 & 37.
Replacement Parts
5008631; 5008632; 5508231; 5508232; 6508631; 6508632
USE ONLY MANUFACTURER’S AUTHORIZED PARTS
FOR PARTS LIST SEE PAGES 38 AND 39.
34
21
Replacement Parts
38 & 39.
36
Replacement Parts List
REPLACEMENT PARTS FOR MODELS 3508231; 3508232; 3508631 and 3508632
PART NO. FOR MODEL
Ref.
Number
Description
3508231 3508232 3508631
4
5
6
1
2
3
7
8
16
17
18
19
20
21
22
9
10
11
12
13
14
15
23
24
25
26
27
27A
28
29
28
29
30
31
32
33
34
35
35
30
31
32
33
34
**
Outer Casing, Less Front Panel
Inner Liner
Heating Element
Bottom Front Panel
Top Front Panel
Fan Shroud
Vent Cover
Opening Pan
Switch Box
Center Front Panel
Internal Wires (All Except Ign. Control)
Header Plate
Junction Box
Gasket-Element Base
Draft Hood Gasket
Flue Collar Gasket
Fan Blade
Motor
Motor Support (2 Req.)
Vibration Isolators (4 Req.)
Transformer 115V-24V
Limit Switch
Fan Switch
Switch Box Cover
Limit Switch
Deflector Baffle Handle
N/A
Lower Element Base Angle
* Vent Enclosure Side (2 Req.)
* Vent Enclosure Front
* Vent Enclosure Side (2 Req.)
* Vent Enclosure Front
* Rear Grille, Two-Way
* Plaster Ground
* Rear Inner Boot, 10-3/4 Inches Long
* Damper
* Rear Outer Boot, 10 Inches Long
* Rear Grille, Two-Way
* Plaster Ground
* Rear Inner Boot, 1-5/8 Inches Long
* Damper
* Rear Outer Boot, 7/8 Inches Long
* Diffusing Grille Kit - Two-Way
* Diffusing Grille Kit - One-Way
* Trip Strip Kit (Not Shown)
12C10
12B15
12C18
12B49
12B50
12B03-1
7B12
12B12
11B05
12C21
3508231
7B57
12B05
P026500
P107900
P027100
P300500
P322544
7B46
P022800
P024200
P309600
P200200
11C68
P323379
11C63
-
7A117
9812
9824
6801
6802
6703
6704
4701
12C10
12B15
12C18
12B49
12B50
12B03-1
7B12
12B12
11B05
12C21
3508232
7B57
12B05
P026500
P107900
P027100
P300500
P322544
7B46
P022800
P024200
P309600
P200200
11C68
P323379
11C63
-
7A117
9812
9824
6801
6802
6703
6704
4701
12C10
12B15
12C18
12B49
12B50
12B03-1
7B12
12B12
11B05
12C21
3508631
7B57
12B05
P026500
P107900
P027100
P300500
P322544
7B46
P022800
P024200
P309600
P200200
11C68
P323379
11C63
-
7A117
9812
9824
6801
6802
6703
6704
4701
**
36
37
38
39
* Oval B/W Vent Kit (Not Shown)
Valve, Natural Gas
9901
–––
Valve, Liquid Propane Gas P322044
Manifold 7B186
Orifice Fitting, Specify Model & Gas Type P090550
Pilot, Natural Gas
–––
Pilot, Liquid Propane Gas P323419
9901
P323210
–––
7B186
P090536
P323418
–––
9901
–––
P322042
7B186
P090550
–––
P323073
3508632
12C10
12B15
12C18
12B49
12B50
12B03-1
7B12
12B12
11B05
12C21
3508632
7B57
12B05
P026500
P107900
P027100
P300500
P322544
7B46
P022800
P024200
P309600
P200200
11C68
P323379
11C63
-
7A117
9812
9824
6801
6802
6703
6704
4701
9901
P323209
–––
7B186
P090536
P323074
–––
Replacement Parts List
–––
Thermocouple
40
Flame Sensor P271100
41 50mm BURNER 12B56
42
43
44
Thermostat
Ignition Control Unit
Wire Assembly
P322016
P321900
P321522
45
46
Wire Assembly (2 required)
Manifold Adapter
P321935/35A
P321887
47
48
49
50
51
52
Ignition Shield
Wire Assembly (2 required)
Front Burner Bracket
Manual Spark Igniter
Piezo Igniter Bracket
Pal Nut
11B139
–––
9B234
–––
–––
–––
31B036 ** Ignition Control Wires
* Not available separately, in kit form only.
** Not Shown.
For part illustration, see pages 32 and 33.
Note: Screws and bolts are standard hardware items, available locally.
–––
P271100
12B56
P322016
P321900
P321522
P321935/35A
P321887
11B139
–––
9B234
–––
–––
–––
31B036
P233100
–––
12B56
P322016
–––
–––
–––
P321888
–––
P321935/35A
9B234
P285500
7A189
P285501
–––
P233100
–––
12B56
P322016
–––
–––
–––
P321888
–––
P321935/35A
9B234
P285500
7A189
P285501
–––
38
Replacement Parts List
REPLACEMENT PARTS FOR MODELS 5008631; 5008632; 5508231; 5508232; 6508631 and 6508632
PART NO. FOR MODEL
Ref.
Number
Description
5008631 5008632 5508231 5508232 6508631
5
6
7
8
1
2
3
4
17
18
19
20
21
22
23
24
25
26
27
28
29
9
10
11
12
13
14
15
16
Outer Casing, Less Front Panel 7C55-4
Inner Liner
Heating Element
Relief Opening Pan
Top Front Panel
Center Front Panel
Switch Box
Limit Switch
Selector Switch
Fan Switch
Bottom Front Panel
Element Base Gasket
Fan Shroud
Relief Pan Gasket
Vent Cover
N/A
Flue Collar Gasket
Header
Limit Switch
Switch Box Cover
Lower Element Base Angle
Transformer, 115V/24V
Junction Box
Internal Wires (All Except Ign.
Motor Support (2 Req.)
Motor
Motor Fan Blade
Deflector Baffle Handle
11B46
7C116
7B108
7B126
11C60
11B103
7B106
7B12
-
7B29
5008631
7B46
11C63
7C55-4
11B46
7C116
7B108
7B126
11C60
11B05 11B05
P200300 P200300
P213400 P213400
P200200 P200200
11B103
P026500 P026500
7B106
P028300 P028300
7B12
-
P027100 P027100
7B114 7B114
P323379 P323379
11C68 11C68
7A117 7A117
P024200 P024200
7B29
5008632
P022800 P022800
7B46
P062101 P062101
P200600 P200600
11C63
7C55-3
7B79
7C68
7D10
7B126
11C59
11B05
P296001
P296201
P200200
11B103
P026500
7B106
P028300
7B12
-
P027100
7B57
P323379
11C68
7A117
P024200
7B29
5508231
P022800
7B46
P062101
P200600
11C63
7C55-3
7B79
7C68
7D10
7B126
11C59
11B05
P296001
P296201
P200200
11B103
P026500
7B106
P028300
7B12
-
P027100
7B57
P323379
11C68
7A117
P024200
7B29
5008232
P022800
7B46
P062101
P200600
11C63
7C55-3
7B79
7C117
7B108
7B126
11C59
11B05
P309600
P296201
P200200
11B103
P026500
7B106
P028300
7B12
-
P027100
7B57
P323379
11C68
7A117
P024200
7B29
6508631
P022800
7B46
P321601
P014300
11C63
30
31
* Vent Enclosure Side (2 Req.)
* Vent Enclosure Front
9812 9812 9812 9812 9812
30
31
* Vent Enclosure Side (2 Req.)
* Vent Enclosure Front
9824 9824
32
33
34
35
36
32
33
34
35
36
37
37
* Rear Grille, Two-Way
* Rear Outer Boot, 10" Long
* Plaster Ground
* Rear Inner Boot, 10-3/4" Long
* Damper
* Rear Grille, Two-Way
* Rear Outer Boot, 7/8" Long
* Plaster Ground
* Rear Inner Boot, 1-5/8" Long
* Damper
* Diffusing Grille Kit (Two-Way)
* Diffusing Grille Kit (One-Way)
6801
6802
6703
6704
6801
6802
6703
6704
38
39
40
41
38
41
* Side Inner Boot, 10-3/4" Long
* Side Outer Boot, 10" Long
* Side Plaster Ground
* Side Grille
* Side Inner Boot, 1" Long
* Side Grille
6701
6702
6701
6702
* * Trim Strip Kit (not shown) 4701 4701
* * Oval B/W Vent Kit (not shown)" 9901
42 Manifold P323656
9901
P323656
9824
6801
6802
6703
6704
6701
6702
4701
9901
P323656
9824
6801
6802
6703
6704
6701
6702
4701
9901
P323656
9824
6801
6802
6703
6704
6701
6702
4701
9901
P323656
6508632
7C55-3
7B79
7C117
7B108
7B126
11C59
11B05
P309600
P296201
P200200
11B103
P026500
7B106
P028300
7B12
-
P027100
7B57
P323379
11C68
7A117
P024200
7B29
6508632
P022800
7B46
P321601
P014300
11C63
9812
9824
6801
6802
6703
6704
6701
6702
4701
9901
P323656
Replacement Parts List
43
44
Orifice Fitting,
Specify Model and Gas (2 required)
Valve, Natural Gas
Valve, Liquid Propane Gas
P332619 P090542
–––
P322042
P323209
–––
P332620 P332622
–––
P322044
P323210
–––
45 Thermostat P322016 P322016 P322016 P322016
Thermocouple P233100 P233100
46
Flame Sensor
Pilot, Natural Gas
–––
–––
47
Pilot, Liquid Propane Gas P323073
48 50mm Burner (with pilot bracket) 12B56
–––
P323074
–––
12B56
49
50
51
52
53
54
55
56
50mm Burner (without pilot
Wire Assembly
Wire Assembly (2 required)
12B57
–––
–––
–––
12B57
–––
–––
–––
Wire Assembly (2 required) P322048/A P322048/A
Manifold Adapter
Ignition Shield
P321888
–––
P321888
–––
Burner Mounting R.H. Bracket 7B187 7B187
57
58 Piezo Igniter Bracket
P285500 P285500
7A303 7A303
59
**
Pal Nut
Ignition Control Wires
P285501 P285501
––– –––
* Not available separately, in kit form only.
** Not Shown.
For part illustration, see pages 34 and 35.
Note: Screws and bolts are standard hardware items, available locally.
––– –––
P271100
–––
P322680
12B56
P271100
P229300
–––
12B56
12B57
P321900
12B57
P321900
P321524 P321524
P322048/A P322048/A
––– –––
P321887 P321887
11B139
7B187
–––
–––
–––
31B036
11B139
7B187
–––
–––
–––
31B036
P090551
–––
P322042
P322016
P233100
–––
–––
P323073
12B56
12B57
–––
–––
–––
P322048/A
P321888
–––
7B187
P285500
7A303
P285501
–––
P090536
P323209
–––
P322016
P233100
–––
P323074
–––
12B56
12B57
–––
–––
–––
P322048/A
P321888
–––
7B187
P285500
7A303
P285501
–––
40
Hints and Information
Service
Hints
If your furnace fails to work correctly, you may avoid the inconvenience and cost of a service call by checking the troubleshooting section on pages 27 thru 29 before you call for service .
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity or this or any other appliance.
How to Order Repair Parts
When ordering repair parts, always give the following Information:
1. MODEL NUMBER
2. MFG. DATE CODE
3. PART NUMBER
4. PART DESCRIPTION
All parts listed herein may be ordered from your equipment supplier. The Model Number of your Williams wall furnace will be found on the nameplate near gas valve, inside control compartment.
WHAT TO DO IF YOU SMELL GAS
Open all of the windows.
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone or cell phone in your building.
Extinguish any open flame.
Immediately call your gas supplier from a neighbor’s phone. If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.