Hydrotech Fleck FAF 2750 Owner's Manual
The Hydrotech Fleck FAF 2750, a commercial-grade water softener, delivers high-quality soft water for various applications. It features a 2750 control valve with a 3200 7- or 12-day timer, enabling customizable regeneration schedules. With a minimum water pressure requirement of 25 pounds per square inch (psi) and a continuous 110-volt, 60 Hertz power supply, this unit ensures efficient operation. It includes a drain line flow controller and injector for optimal water flow management.
Advertisement
Advertisement
MODEL 2750 DOWNFLOW
CONTROL VALVE
Service Manual
IMPORTANT: Fill in pertinent information on page 2 for future reference.
MODEL 2750 DOWNFLOW
Job Specification Sheet
* JOB NO. _________________________________________________________
* MODEL NO. ______________________________________________________
* WATER TEST_____________________________________________________
* CAPACITY PER UNIT ___________________________
* MINERAL TANK SIZE DIA. ______ HEIGHT_________
* BRINE TANK SIZE & SALT SETTING PER REGENERATION:
_________________________________________________________________
* 2750 CONTROL VALVE SPECIFICATIONS
1) Type of Timer (see pages 16,17, & 18)
A) 7 day or 12 day
B) *310 to 5,270 gallon meter or
*1,550 to 26,350 gallon meter
* Other _______________________________________________________
C) Meter Wiring Package
1) System #4 - 1 tank; 1 meter; immediate or delayed regeneration
2) System #5 - 2 tanks; 2 meters; interlock
3) System #6 - 2 tanks; 1 meter; series regeneration
4) System #7 - 2 tanks; 1 meter; alternator
2) Timer Program Settings (see pages 18 and 19)
A) Backwash _______________________ min.
B) Brine & Slow Rinse ________________ min.
C) Rapid Rinse _____________________ min.
D) Brine Tank Refill___________________ min.
3) Drain Line Flow Controller ______________ gpm
4) Brine Line Flow Controller ______________ gpm
5) Injector Size # _______________________
6) Service Valve Operation Units (SVO)
Size of Service Valve _______________________________________________ .
Page 2
Printed in U.S.A.
MODEL 2750 DOWNFLOW
General Commercial Pre-Installation Check List
WATER PRESSURE: A minimum of 25 pounds of water pressure is required for regeneration valve to operate effectively.
ELECTRICAL FACILITIES: A continuous 110 volt, 60 Hertz current supply is required. Make certain the current supply is always hot and cannot be turned off with another switch. (Other voltages available.)
EXISTING PLUMBING: Condition of existing plumbing should be free from lime and iron buildup. Piping that is built up heavily with lime and/or iron should be replaced. If piping is clogged with iron, a separate iron filter unit should be installed ahead of the water softener.
LOCATION OF SOFTENER AND DRAIN: The softener should be located close to a drain.
BY-PASS VALVES: Always provide for the installation of a by-pass valve.
CAUTION: Water pressure is not to exceed 120 p.s.i., water temperature is not to exceed 100˚ F, and the unit cannot be subjected to freezing conditions.
INSTALLATION INSTRUCTIONS
1. Place the softener tank where you want to install the unit making sure the unit is level and on a firm base.
(Maximum 4 feet apart for twin units.)
2. All plumbing should be done in accordance with local plumbing codes. The pipe size for the drain line should be the same size as the drain line flow control female connection. Water meters are to be installed on soft water outlets.
Twin units with (1) one meter shall be installed on common soft water outlet of units.
3. Solder joints near the drain must be done prior to connecting the Drain Line Flow Control fitting. Leave at least 6
″ between the DLFC and solder joints when soldering when the pipes are connected on the DLFC. Failure to do this could cause interior damage to the DLFC.
4. Teflon tape is the only sealant to be used on the drain fitting. The drain from twin units may be run through a common line.
5. Make sure that the floor is clean beneath the salt storage tank and that it is level.
6. Place approximately 1
″ of water above the grid plate (if used) in your salt tank. Salt may be placed in the unit at this time.
7. On units with a by-pass, place in by-pass position. Turn on the main water supply. Open a cold soft water tap nearby and let run a few minutes or until the system is free from foreign material (usually solder) that may have resulted from the installation.
8. Place the by-pass in service position.
9. Manually index the softener control into “service” position and let water flow into the mineral tank. When water flow stops, open a cold water tap nearby and let run until air pressure is relieved.
10. Electrical: All electrical connections must be connected according to codes. Use electrical conduit if applicable.
Remote meter systems and Twin meter system wiring diagrams are on page 25. Plug into power supply.
Page 3
Printed in U.S.A.
MODEL 2750 DOWNFLOW
Water Conditioners Flow Diagrams
1
SERVICE POSITION
BRINE VALVE
FLOW CONTROL
INLET
MINERAL TANK
BRINE TANK
Hard water enters unit at valve inlet and flows down thru the mineral in the mineral tank.
Conditioned water enters center tube thru the bottom distributor center tube
around the piston and out the top outlet of the valve.
then flows up thru the
2
BACKWASH POSITION
3
BRINE POSITION
BRINE VALVE
FLOW CONTROL
BRINE VALVE
FLOW
CONTROL
INLET
INLET
BRINE
TANK
MINERAL
TANK
BRINE
TANK
MINERAL
TANK
Hard water enters unit at valve inlet center tube
flows thru piston
down
thru bottom distributor and up thru the mineral
around the piston and out the drain line.
Hard water enters unit at valve inlet
flows up into injector housing and down thru nozzle and orifice to draw brine from the brine tank
brine flows down thru mineral and enters the center tube thru bottom distributor and out thru the drain line.
Page 4
Printed in U.S.A.
MODEL 2750 DOWNFLOW
Water Conditioners Flow Diagrams (Cont’d.)
4
SLOW RINSE POSITION
BRINE VALVE
FLOW CONTROL
INLET
MINERAL TANK
BRINE TANK
Hard water enters unit at valve inlet and orifice distributor
around the piston
flows up into injector housing and down thru nozzle down thru mineral
enters center tube thru bottom
flows up thru center tube
around piston and out thru drain line.
5
RAPID RINSE
6
BRINE TANK FILL POSITION
BRINE TANK
FLOW
CONTROL
BRINE TANK
FLOW
CONTROL
INLET
INLET
BRINE
TANK
MINERAL
TANK
BRINE
TANK
MINERAL
TANK
Hard water flows directly from inlet down thru mineral into center tube bottom distributor and up thru center tube
around piston and out thru the drain line.
Hard water enters unit at valve inlet housing
flows up thru the injector
thru the brine valve to fill the brine tank.
Page 5
Printed in U.S.A.
MODEL 2750 DOWNFLOW
Control Drive Assembly
(see opposite page for parts list)
3 4
25
24
5
1
Page 6
22
23
18
7
2
7
20
11
12
13
14
10
21
Printed in U.S.A.
19
18
17
16
15
MODEL 2750 DOWNFLOW
Control Drive Assembly
Parts List
Item No.
Quantity Part No.
Description
1 . . . . . . . . . 1 . . . . . . . . . . 14884 . . . . . . . . . . . . . Back Plate
1 . . . . . . . . . . 11209 . . . . . . . . . . . . . Back Plate - Slant Front (not shown)
1 . . . . . . . . . . 15156 . . . . . . . . . . . . . Back Plate - SVO (not shown)
2 . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer - 3200 7 Day
- 3200 12 Day
- 3210 Meter
3 . . . . . . . . . 1 . . . . . . . . . . 11838 . . . . . . . . . . . . . Power Cord
4 . . . . . . . . . 1 . . . . . . . . . . 13547 . . . . . . . . . . . . . Strain Relief
5 . . . . . . . . . 1 . . . . . . . . . . 11667 . . . . . . . . . . . . . Wire Harness
7 . . . . . . . . . 5 . . . . . . . . . . 10872 . . . . . . . . . . . . . Screw - Motor Mounting
8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Assigned
9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Assigned
10 . . . . . . . . . 1 . . . . . . . . . . 10774 . . . . . . . . . . . . . Bracket - Motor Mounting
11 . . . . . . . . . 2 . . . . . . . . . . 10231 . . . . . . . . . . . . . Screw - Drive Mounting
12 . . . . . . . . . 2 . . . . . . . . . . 10302 . . . . . . . . . . . . . Insulator
13 . . . . . . . . . 2 . . . . . . . . . . 10218 . . . . . . . . . . . . . Switch
14 . . . . . . . . . 1 . . . . . . . . . . 10909 . . . . . . . . . . . . . Connecting Link Pin
15 . . . . . . . . . 3 . . . . . . . . . . 10250 . . . . . . . . . . . . . Retaining Ring
16 . . . . . . . . . 1 . . . . . . . . . . 10621 . . . . . . . . . . . . . Connecting Link
17 . . . . . . . . . 1 . . . . . . . . . . 12102 . . . . . . . . . . . . . Drive Cam - RR
1 . . . . . . . . . . 12576 . . . . . . . . . . . . . Drive Cam - STF
18 . . . . . . . . . 2 . . . . . . . . . . 10338 . . . . . . . . . . . . . Roll Pin
19 . . . . . . . . . 1 . . . . . . . . . . 13366 . . . . . . . . . . . . . Drive Bearing
20 . . . . . . . . . 2 . . . . . . . . . . 14923 . . . . . . . . . . . . . Screw - Switch Mounting
21 . . . . . . . . . 1 . . . . . . . . . . 10769 . . . . . . . . . . . . . Motor
22 . . . . . . . . . 1 . . . . . . . . . . 11826 . . . . . . . . . . . . . Bracket - Brine Valve Side
23 . . . . . . . . . 1 . . . . . . . . . . 12777 . . . . . . . . . . . . . Brine Valve Cam - STF
1 . . . . . . . . . . 10815 . . . . . . . . . . . . . Brine Valve Cam - RR (not shown)
1 . . . . . . . . . . 12472 . . . . . . . . . . . . . Brine Valve Cam - SVO (not shown) - TRI
24 . . . . . . . . . 1 . . . . . . . . . . 15441 . . . . . . . . . . . . . Meter Cable Guide Assembly
25 . . . . . . . . . 1 . . . . . . . . . . 15513 . . . . . . . . . . . . . Meter Cable Assembly
26 . . . . . . . . . 2 . . . . . . . . . . 10300 . . . . . . . . . . . . . Screw - Timer Mounting (not shown)
27 . . . . . . . . . 2 . . . . . . . . . . 15742 . . . . . . . . . . . . . Screw (not shown)
28 . . . . . . . . . 2 . . . . . . . . . . 15833 . . . . . . . . . . . . . Spacer, Cover (not shown)
29 . . . . . . . . . 1 . . . . . . . . . . 19291-020. . . . . . . . . . Cover, 1 Piece, Black (not shown)
30 . . . . . . . . . 2 . . . . . . . . . . 19367 . . . . . . . . . . . . . Screw, Cover (not shown)
Page 7
Printed in U.S.A.
MODEL 2750 DOWNFLOW
Control Valve with 1700 Injector
(see opposite page for parts list)
13
16
15
14
12
11
10 24 17 18
28
9
1
30
2
3
19
20
21
22
19
Page 8
4
5
6
7
8
Printed in U.S.A.
27
26
25
29
15
14
MODEL 2750 DOWNFLOW
Control Valve
Parts List
Item No.
Quantity Part No.
Description
1 . . . . . . . . . 1 . . . . . . . . . . 14749 . . . . . . . . . . . . . Valve Body
2 . . . . . . . . . 6 . . . . . . . . . . 10545 . . . . . . . . . . . . . Seal
3 . . . . . . . . . 5 . . . . . . . . . . 11451 . . . . . . . . . . . . . Spacer
16589 . . . . . . . . . . . . . Spacer, Hot Water
4 . . . . . . . . . 1 . . . . . . . . . . 14451 . . . . . . . . . . . . . Piston
5 . . . . . . . . . 1 . . . . . . . . . . 14452 . . . . . . . . . . . . . Piston Rod
6 . . . . . . . . . 1 . . . . . . . . . . 10234 . . . . . . . . . . . . . O-Ring - End Plug
7 . . . . . . . . . 1 . . . . . . . . . . 10209 . . . . . . . . . . . . . Quad Ring - Piston Rod
8 . . . . . . . . . 1 . . . . . . . . . . 10598 . . . . . . . . . . . . . End Plug Assembly
10598-01 . . . . . . . . . . End Plug Assembly, Hot Water
9 . . . . . . . . . 1 . . . . . . . . . . 14805 . . . . . . . . . . . . . Injector Body Gasket
10 . . . . . . . . . 1 . . . . . . . . . . 14802 . . . . . . . . . . . . . Injector Throat
11 . . . . . . . . . 1 . . . . . . . . . . 17777 . . . . . . . . . . . . . Injector Body
12 . . . . . . . . . 1 . . . . . . . . . . 14801 . . . . . . . . . . . . . Injector Nozzle
13 . . . . . . . . . 1 . . . . . . . . . . 14803 . . . . . . . . . . . . . Injector Screen
14 . . . . . . . . . 1 . . . . . . . . . . 10229 . . . . . . . . . . . . . Injector Cover Gasket
15 . . . . . . . . . 1 . . . . . . . . . . 11893 . . . . . . . . . . . . . Injector Cover
10228 . . . . . . . . . . . . . Injector Cover, Hot Water
16 . . . . . . . . . 2 . . . . . . . . . . 14804 . . . . . . . . . . . . . Screw - Injector Body
17 . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Washer - Flow Control (specify size)
18 . . . . . . . . . 1 . . . . . . . . . . 15177 . . . . . . . . . . . . . Flow Control Housing
19 . . . . . . . . . 2 . . . . . . . . . . 11710 . . . . . . . . . . . . . O-Ring Base
20 . . . . . . . . . 1 . . . . . . . . . . 11208 . . . . . . . . . . . . . O-Ring Base
21 . . . . . . . . . 1 . . . . . . . . . . 12461 . . . . . . . . . . . . . Adapter Base 2-1/2-8 Thd
22 . . . . . . . . . 1 . . . . . . . . . . 10381 . . . . . . . . . . . . . O-Ring - Top of Tank
24 . . . . . . . . . 2 . . . . . . . . . . 11224 . . . . . . . . . . . . . Screw - Valve Mounting
25 . . . . . . . . . 1 . . . . . . . . . . 17776 . . . . . . . . . . . . . Injector Body
26 . . . . . . . . . 1 . . . . . . . . . . 10914 . . . . . . . . . . . . . Injector Throat
27 . . . . . . . . . 1 . . . . . . . . . . 10913 . . . . . . . . . . . . . Injector Nozzle
28 . . . . . . . . . 1 . . . . . . . . . . 10227 . . . . . . . . . . . . . Injector Screen
29 . . . . . . . . . 2 . . . . . . . . . . 10692 . . . . . . . . . . . . . Screw - Injector Body
30 . . . . . . . . . 1 . . . . . . . . . . 10757 . . . . . . . . . . . . . End Spacer
10757B . . . . . . . . . . . . End Spacer, Hot Water
31 . . . . . . . . . 1 . . . . . . . . . . 16221 . . . . . . . . . . . . . Air Disperser - 1600 Injector (not shown)
Page 9
Printed in U.S.A.
MODEL 2750 DOWNFLOW
1600 Series Brine System Assembly
7
3 2 1
4
5
6
4
5
20
19
18
17
16
15
14
5
3
10
11
4
8
9
PARTS LIST
Item No.
Quantity Part No.
Description
1 . . . . . . . . . . . 1. . . . . . . . . . . . 10328. . . . . . . . . . . . . . . . 90
°
Elbow - 1/4
″
Pipe Thd. to 3/8
″
Tube
2 . . . . . . . . . . . 1. . . . . . . . . . . . 12767. . . . . . . . . . . . . . . . Brine Line Screen
3 . . . . . . . . . . . 2. . . . . . . . . . . . 10332. . . . . . . . . . . . . . . . Insert Sleeve (3/8
″
Tube)
4 . . . . . . . . . . . 3. . . . . . . . . . . . 10329. . . . . . . . . . . . . . . . Fitting Nut (3/8
″
Tube)
5 . . . . . . . . . . . 3. . . . . . . . . . . . 10330. . . . . . . . . . . . . . . . Derlin Sleeve (3/8
″
Tube)
6 . . . . . . . . . . . 1. . . . . . . . . . . . 15221. . . . . . . . . . . . . . . . Brine Valve Tube
7 . . . . . . . . . . . 1. . . . . . . . . . . . 60002. . . . . . . . . . . . . . . . #500 Air Check Assembly
60003. . . . . . . . . . . . . . . . #500 Air Check Assembly, Hot Water
8 . . . . . . . . . . . 1. . . . . . . . . . . . 12794. . . . . . . . . . . . . . . . 90˚ Elbow - 3/8
″
Tube to 3/8
″
Tube
9 . . . . . . . . . . . 1. . . . . . . . . . . . Not Supplied . . . . . . . . . . Brine Line Tube (3/8
″
Flexible Tube)
10. . . . . . . . . . . 1. . . . . . . . . . . . 10250. . . . . . . . . . . . . . . . Retaining Ring
11. . . . . . . . . . . 1. . . . . . . . . . . . 11749. . . . . . . . . . . . . . . . Stem Guide
12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Assigned
13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Assigned
14. . . . . . . . . . . 1. . . . . . . . . . . . 10249. . . . . . . . . . . . . . . . Brine Valve Spring
15. . . . . . . . . . . 1. . . . . . . . . . . . 12550. . . . . . . . . . . . . . . . Quad Ring
16. . . . . . . . . . . 1. . . . . . . . . . . . 12748. . . . . . . . . . . . . . . . Brine Valve Body
17. . . . . . . . . . . 1. . . . . . . . . . . . 12552. . . . . . . . . . . . . . . . Brine Valve Stem
18. . . . . . . . . . . 1. . . . . . . . . . . . 12626. . . . . . . . . . . . . . . . Brine Valve Seat
19. . . . . . . . . . . 1. . . . . . . . . . . . 11982. . . . . . . . . . . . . . . . O-Ring
20. . . . . . . . . . . 1. . . . . . . . . . . . 60020-25 . . . . . . . . . . . . . BLFC .25 GPM
60020-50 . . . . . . . . . . . . . BLFC .50 GPM
60020-100 . . . . . . . . . . . . BLFC 1.0 GPM
Page 10
Printed in U.S.A.
MODEL 2750
1700 Series Brine System
17 15 16
1
2
3
16
4
5
20
21
14
6
7
8
18 14
20
21
9
10
11
12
13
15
19
PARTS LIST
Item No.
Quantity Part No.
Description
1. . . . . . . . 1 . . . . . . 14792 . . . . . . . End Plug
2. . . . . . . . 1 . . . . . . 13201 . . . . . . . O-Ring - End Plug
3. . . . . . . . 1 . . . . . . . . . . . . . . . . . . . Washer Flow Control (specify size)
4. . . . . . . . 1 . . . . . . 14785 . . . . . . . Flow Control Retainer
5. . . . . . . . 2 . . . . . . 14811 . . . . . . . Piston Seals
6. . . . . . . . 1 . . . . . . 14798 . . . . . . . Spacer
7. . . . . . . . 1 . . . . . . 14795 . . . . . . . Brine Valve Piston
8. . . . . . . . 1 . . . . . . 14797 . . . . . . . Brine Valve Stem
9. . . . . . . . 1 . . . . . . .14790 . . . . . . . Brine Valve Body
10. . . . . . . . 1 . . . . . . .12550 . . . . . . . Quad Ring - Brine Stem
11. . . . . . . . 1 . . . . . . .15310 . . . . . . . Spring - Brine Valve
12. . . . . . . . 1 . . . . . . .10250 . . . . . . . Retaining Ring
13. . . . . . . . 1 . . . . . . .15517 . . . . . . . Stem Guide
14. . . . . . . . 2 . . . . . . .15415 . . . . . . . Insert
15. . . . . . . . 2 . . . . . . .15414 . . . . . . . Nut & Sleeve
16. . . . . . . . 2 . . . . . . .15413 . . . . . . . Elbow
17. . . . . . . . 1 . . . . . . .15416 . . . . . . . Brine Tube
18. . . . . . . . 1 . . . . . . .16977 . . . . . . . Reducer Coupling, 1/2
″
NPT to 1/8
″
NPT
19. . . . . . . . 1 . . . . . . .60009 . . . . . . . #900 Air Check Assembly
60009-01 . . . . #900 Air Check Assembly, Hot Water
20. . . . . . . . 2 . . . . . . .16123 . . . . . . . Nut
21. . . . . . . . 2 . . . . . . .16124 . . . . . . . Sleeve
Page 11
Printed in U.S.A.
MODEL 2750 DOWNFLOW
Service Valve Operator
10 9 8
13
10
9
8
13
12
10
9
8
11
12
10
9
8
7
6
9
8
10
5
4
3
2
1
PARTS LIST
Item No.
Quantity Part No.
Description
1 . . . . . . . . . . . 1. . . . . . . . . . . . 11749. . . . . . . . . . . . . . . . Guide, Brine Valve Stem
2 . . . . . . . . . . . 1. . . . . . . . . . . . 10250. . . . . . . . . . . . . . . . Retaining Ring
3 . . . . . . . . . . . 1. . . . . . . . . . . . 10249. . . . . . . . . . . . . . . . Spring, Brine Valve
4 . . . . . . . . . . . 1. . . . . . . . . . . . 12550. . . . . . . . . . . . . . . . Quad Ring
5 . . . . . . . . . . . 1. . . . . . . . . . . . 10785. . . . . . . . . . . . . . . . Service Actuator Assembly - .25 gpm
6 . . . . . . . . . . . 1. . . . . . . . . . . . 12552. . . . . . . . . . . . . . . . Brine Valve Stem, 1600
7 . . . . . . . . . . . 1. . . . . . . . . . . . 12626. . . . . . . . . . . . . . . . Seat, Brine Valve
8 . . . . . . . . . . . 5. . . . . . . . . . . . 10332. . . . . . . . . . . . . . . . Insert,
9 . . . . . . . . . . . 5. . . . . . . . . . . . 10330. . . . . . . . . . . . . . . . Sleeve, 3/8
″
Delrin
10. . . . . . . . . . . 5. . . . . . . . . . . . 10329. . . . . . . . . . . . . . . . Nut, 3/8
″
Brass
11. . . . . . . . . . . 1. . . . . . . . . . . . 10328. . . . . . . . . . . . . . . . Elbow, 90˚ 1/4
″
NPT x 3/8
″
12. . . . . . . . . . . 2. . . . . . . . . . . . 12897. . . . . . . . . . . . . . . . Tube
13. . . . . . . . . . . 2. . . . . . . . . . . . 16730. . . . . . . . . . . . . . . . Connector, Male 1/8
″
NPT to 3/8
″
T
Page 12
Printed in U.S.A.
MODEL 2750 ECONOMINDER
1
″
Meter Assembly
5A
4
3
2
1
6
6
4
5B
7
8
9
10
PARTS LIST
Item No.
Quantity Part No.
Description
1 . . . . . . . . . . . 1 . . . . . . . . . . . 14959 . . . . . . . . . . . . . . . Meter Body
2 . . . . . . . . . . . 1 . . . . . . . . . . . 13882 . . . . . . . . . . . . . . . Post, Meter Impeller
3 . . . . . . . . . . . 1 . . . . . . . . . . . 13509 . . . . . . . . . . . . . . . Impeller
4 . . . . . . . . . . . 1 . . . . . . . . . . . 13847 . . . . . . . . . . . . . . . O-Ring - Meter Cover
5A . . . . . . . . . . 1 . . . . . . . . . . . 15218 . . . . . . . . . . . . . . . Meter Cover Assembly (Std.)
5B . . . . . . . . . . 1 . . . . . . . . . . . 15237 . . . . . . . . . . . . . . . Meter Cover Assembly (Extended Range)
6 . . . . . . . . . . . 4 . . . . . . . . . . . 12112 . . . . . . . . . . . . . . . Screw - Meter Cover
7 . . . . . . . . . . . 1 . . . . . . . . . . . 14960 . . . . . . . . . . . . . . . Flow Straightener
8 . . . . . . . . . . . 1 . . . . . . . . . . . 13287 . . . . . . . . . . . . . . . O-Ring - Quick Connect
9 . . . . . . . . . . . 1 . . . . . . . . . . . 14961 . . . . . . . . . . . . . . . Nipple - Quick Connect
10 . . . . . . . . . . 1 . . . . . . . . . . . 14962 . . . . . . . . . . . . . . . Nut - Quick Connect
11 . . . . . . . . . . 1 . . . . . . . . . . . 15308 . . . . . . . . . . . . . . . Brass 1
″
Coupling (not shown)
Page 13
Printed in U.S.A.
MODEL 2750 ECONOMINDER
Timer Assembly
(see opposite page for parts list)
1
38
2
3
5
6
7
Page 14
37
8
9
10
18
19
20
7
11
12
13
14
15
16
6
23
26
27
28
31
32
33
34
35
36
29
21
24
25
Printed in U.S.A.
MODEL 2750 ECONOMINDER
Timer Assembly
Parts List
Item No.
Quantity Part No.
Description
1 . . . . . . . . . . . 1 . . . . . . . . . . . 13708-01 . . . . . . . . . . . . . Timer Housing Assembly
2 . . . . . . . . . 1 . . . . . . . . . . 13802 . . . . . . . . . . . . . Cycle Actuator Gear
3 . . . . . . . . . 1 . . . . . . . . . . 40096-24. . . . . . . . . . . 24 Hour Gear Assembly, 12 Midnight
40096-02. . . . . . . . . . . 24 Hour Gear Assembly, 2 AM
5 . . . . . . . . . 1 . . . . . . . . . . 13886-01. . . . . . . . . . . Knob
6 . . . . . . . . . 4 . . . . . . . . . . 13296 . . . . . . . . . . . . . Screw - Timer Knob & Motor Plate Mtg.
7 . . . . . . . . . 2 . . . . . . . . . . 11999 . . . . . . . . . . . . . Button Decal
8 . . . . . . . . . 1 . . . . . . . . . . 60405-30. . . . . . . . . . . Program Wheel Assembly
9 . . . . . . . . . 1 . . . . . . . . . . 13806 . . . . . . . . . . . . . Program Wheel Retainer
10 . . . . . . . . . 1 . . . . . . . . . . 13748 . . . . . . . . . . . . . Screw - Program Wheel Mtg.
11 . . . . . . . . . 1 . . . . . . . . . . 14265 . . . . . . . . . . . . . Spring Clip
12 . . . . . . . . . 1 . . . . . . . . . . 15424 . . . . . . . . . . . . . Spring - Detent
13 . . . . . . . . . 1 . . . . . . . . . . 15066 . . . . . . . . . . . . . Ball -1/4 in.dia.
14 . . . . . . . . . 1 . . . . . . . . . . 13911 . . . . . . . . . . . . . Main Drive Gear
15 . . . . . . . . . 1 . . . . . . . . . . 19210 . . . . . . . . . . . . . Program Wheel
16 . . . . . . . . . 21 . . . . . . . . . 15493 . . . . . . . . . . . . . Roll Pin
18 . . . . . . . . . 1 . . . . . . . . . . 13018 . . . . . . . . . . . . . Idler Shaft
19 . . . . . . . . . 1 . . . . . . . . . . 13312 . . . . . . . . . . . . . Spring - Idler
20 . . . . . . . . . 1 . . . . . . . . . . 13017 . . . . . . . . . . . . . Idler Gear
21 . . . . . . . . . 1 . . . . . . . . . . 13164 . . . . . . . . . . . . . Drive Gear
23 . . . . . . . . . 1 . . . . . . . . . . 13887 . . . . . . . . . . . . . Motor Mounting Plate
24 . . . . . . . . . 1 . . . . . . . . . . 18743 . . . . . . . . . . . . . Motor - 110 V., 60Hz.
19659 . . . . . . . . . . . . . Motor -
-
24V., 60 Hz.
25 . . . . . . . . . 3 . . . . . . . . . . 13278 . . . . . . . . . . . . . Screw - Motor Mounting & Ground Wire
26 . . . . . . . . . 1 . . . . . . . . . . 13830 . . . . . . . . . . . . . Drive Pinion - Program Wheel
27 . . . . . . . . . 1 . . . . . . . . . . 13831 . . . . . . . . . . . . . Clutch - Drive Pinion
28 . . . . . . . . . 1 . . . . . . . . . . 14276 . . . . . . . . . . . . . Spring
29 . . . . . . . . . 1 . . . . . . . . . . 14253 . . . . . . . . . . . . . Spring Retainer
30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Assigned
31 . . . . . . . . . 2 . . . . . . . . . . 11384 . . . . . . . . . . . . . Screw-Timer Hinge
32 . . . . . . . . . 1 . . . . . . . . . . 13881 . . . . . . . . . . . . . Hinge Bracket
33 . . . . . . . . . 3 . . . . . . . . . . 14087 . . . . . . . . . . . . . Insulator
34 . . . . . . . . . 1 . . . . . . . . . . 10896 . . . . . . . . . . . . . Switch
35 . . . . . . . . . 1 . . . . . . . . . . 15320 . . . . . . . . . . . . . Switch
36 . . . . . . . . . 2 . . . . . . . . . . 11413 . . . . . . . . . . . . . Screw - Switch Mounting
37 . . . . . . . . . 1 . . . . . . . . . . 14007 . . . . . . . . . . . . . Decal - Time of Day
38 . . . . . . . . . 1 . . . . . . . . . . 14045 . . . . . . . . . . . . . Decal - Instructions
39 . . . . . . . . . 1 . . . . . . . . . . 13902 . . . . . . . . . . . . . Harness - Not Shown
40 . . . . . . . . . 2 . . . . . . . . . . 12681 . . . . . . . . . . . . . Wire Connector - Not Shown
41 . . . . . . . . . 1 . . . . . . . . . . 15354-01. . . . . . . . . . . Ground Wire - Not Shown
Page 15
Printed in U.S.A.
MODEL 2750 ECONOMINDER
1
″
Commercial Demand Regeneration Control
Timer Settings
Typical Programming Procedure
Calculate the gallon capacity of the system, subtract the necessary reserve requirement and set the appropriate gallons available opposite the small white dot on the program wheel gear. Note, drawing shows 10,000 gallons setting. The capacity (gallons) arrow denotes remaining gallons exclusive of calculated reserve.
How To Set The Time Of Day:
Press and hold the red button in to disengage the drive gear.
Turn the large gear until the actual time of day is opposite the time of day pointer.
Release the red button to again engage the drive gear.
* 24 HOUR
GEAR
How To Manually Regenerate Your Water Conditioner
At Any Time.
Turn the manual regeneration knob clockwise.
This slight movement of the manual regeneration knob engages the program wheel and starts the regeneration program.
The black center knob will make one revolution in the following approximately three hours and stop in the position shown in the drawing.
Even though it takes three hours for this center knob to complete one revolution, the regeneration cycle of your unit might be set for only one half of this time.
In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain line.
Immediate Regeneration Timers:
These timers do not have a 24 hour gear. Setting the gallons on the program wheel and manual regeneration procedure are the same as previous instructions.
MANUAL
REGENERATION
KNOB
SERVICE
POSITION
INDICATOR
PROGRAM
WHEEL
Page 16
RED TIME
SET BUTTON
WHITE DOT
GALLONS LABEL
* Immediate regeneration times do not have 24 hour gear. No time of day can be set.
Printed in U.S.A.
MODEL 3200 TIMER
Timer Setting Procedure
How To Set Days On Which Water Conditioner
Is To Regenerate:
Rotate the skipper wheel until the number “1” is at the red pointer. Set the days that regeneration is to occur by sliding tabs on the skipper wheel outward to expose trip fingers. Each tab is one day. Finger at red pointer is tonight.
Moving clockwise from the red pointer, extend or retract fingers to obtain the desired regeneration schedule.
How To Set The Time of Day:
Press and hold the red button in to disengage the drive gear.
Turn the large gear until the actual time of day is at the time of day pointer.
Release the red button to again engage the drive gear.
How To Manually Regenerate Your Water Conditioner
At Any Time:
Turn the manual regeneration knob clockwise.
This slight movement of the manual regeneration knob engages the program wheel and starts the regeneration program.
The black center knob will make one revolution in the following approximately three hours and stop in the position shown in the drawing.
Even thought it takes three hours for this center knob to complete one revolution, the regeneration cycle of your unit might be set only one half of this time.
In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain line.
How to Adjust Regeneration Time:
1. Disconnect the power source.
2. Locate the three screws behind the manual regeneration knob by pushing the red button in and rotating the 24 hour dial until each screw appears in the cut out portion of the manual regeneration knob.
3. Loosen each screw slightly to release the pressure on the time plate from the 24 hour gear.
4. Locate the regeneration time pointer on the inside of the 24 hour dial in the cut out.
5. Turn the time plate so the desired regeneration time aligns next to the raised arrow.
6. Push the red button in and rotate the 24 hour dial.
Tighten each of the three screws.
7. Push the red button and locate the pointer one more time to ensure the desired regeneration time is correct.
8. Reset the time of day and restore power to the unit.
SERVICE
POSITION
INDICATOR
24 HR. GEAR
MANUAL REGENERATION
KNOB
RED TIME
SET BUTTON
SKIPPER WHEEL, 12 DAY
(SHOWS EVERY OTHER
DAY REGENERATION)
Printed in U.S.A.
3200 ADJUSTABLE REGENERATION TIMER
IMPORTANT!
SALT LEVEL MUST ALWAYS BE ABOVE WATER
LEVEL IN BRINE TANK.
Page 17
MODEL 3200 & 3210 Timer Series
Regenerating Cycle Program Setting Procedure
(Brine Tank Refill Separate from Rapid Rinse)
How To Set The Regeneration Cycle Program:
The regeneration cycle program on your water conditioner has been factory preset, however, portions of the cycle or program may be lengthened or shortened in time to suit local conditions.
3200 & 3210 Series Timers (Figure to Right)
To expose cycle program wheel, grasp timer in upper lefthand corner and pull, releasing snap retainer and swinging timer to the right.
To change the regeneration cycle program, the program wheel must be removed. Grasp program wheel and squeeze protruding lugs toward center, lift program wheel off timer. (Switch arms may require movement to facilitate removal.)
Return timer to closed position engaging snap retainer in back plate. Make certain all electrical wires locate above snap retainer post.
BRINE & RINSE
SECTION
(2 MIN. PER HOLE)
PIN STORAGE
Timer Setting Procedure for 3200 & 3210 Timer
PROGRAM
WHEEL FOR
CONTROL OF
REGENERATION
CYCLE
RAPID
RINSE
SECTION
(2 MIN.
PER PIN)
BRINE TANK
How To Change The Length Of The Backwash Time:
The program wheel as shown in the drawing is in the service position. As you look at the numbered side of the program wheel, the group of pins starting at zero determines the length of time your unit will backwash.
FOR EXAMPLE: If there are six pins in this section, the time of backwash will be 12 min. (2min. per pin). To change the length of backwash time, add or remove pins as required. The number of pins times two equals the backwash time in minutes.
How To Change The Length Of Brine And Rinse Time:
The group of holes between the last pin in the backwash section and the second group of pins determines the length of time that your unit will brine and rinse (2 min. per hole.)
To change the length of brine and rinse time, move the rapid rinse group of pins to give more or fewer holes in the brine and rinse section. Number of holes time two equals brine and rinse time in minutes.
How To Change The Length Of Rapid Rinse:
The second group of pins on the program wheel determines the length of time that your water conditioner will rapid rinse. (2 min. per pin.)
BACKWASH
SECTION
(2 MIN. PER PIN)
To change the length of rapid time, add or remove pins at the higher numbered end of this section as required. The number of pins times two equals the rapid rinse time in minutes.
How To Change The Length Of Brine Tank Refill Time:
The second group of holes in the program wheel determines the length of time that your water conditioner will refill the brine tank. (2 min. per hole.)
To change the length of refill time, move the two pins at the end of the second group of holes as required.
The regeneration cycle is complete when the outer microswitch is tripped by the two pin set at end of the brine tank refill section. The program wheel, however, will continue to rotate until the inner micro-switch drops into the notch on the program wheel.
Page 18
Printed in U.S.A.
MODEL 2750 DOWNFLOW
Flow Data & Injector Draw Rates
Printed in U.S.A.
Page 19
2750 System #4
Valve Wiring
Page 20
Printed in U.S.A.
2750 System #4 With Remote Meter
Valve Wiring
Printed in U.S.A.
Page 21
2750 System #5
Valve Wiring
Page 22
Printed in U.S.A.
2750 System #6
Valve Wiring
Printed in U.S.A.
Page 23
2750 24V/120V System #7
Valve Wiring
Page 24
Printed in U.S.A.
2750 230V System #7
Valve Wiring
Printed in U.S.A.
Page 25
MODEL 2750 DOWNFLOW
Service Instructions
PROBLEM CAUSE CORRECTION
1.
2.
7.
Softener fails to regenerate.
Hard water.
Excessive water in brine tank.
A.
Electrical service to unit has been interrupted.
B.
Timer is defective.
C.
Power failure.
A.
B.
C.
F.
A.
B.
By-pass valve is open.
No salt in brine tank.
Injectors or screen plugged.
D.
Insufficient water flowing into brine tank.
E.
Hot water tank hardness.
Leak at distributor tube.
G. Internal valve leak
Plugged drain line flow control.
Plugged injector system.
C.
Timer not cycling.
D.
Foreign material in brine valve.
E.
Foreign material in brine line flow control.
A.
Assure permanent electrical service (check fuse, plug, pull chain or switch).
B.
C.
Replace timer.
Reset time of day.
A.
Close by-pass valve.
B.
Add salt to brine tank and maintain salt level above water level.
C.
Clean injector screen.
D.
Check brine tank fill time and clean brine line flow if plugged.
E.
Repeated flushings of the hot water tank is required.
F.
Make sure distributor tube is not cracked. Check O-Ring and tube pilot.
G. Replace seals and spacers and/or piston.
A.
Check salt usage and salt setting.
B.
See problem No. 7.
A.
Clean line to water conditioner.
3.
4.
6.
Unit used too much salt.
Loss of water pressure.
Iron in conditioned water.
A.
Improper salt setting.
B.
Excessive water in brine tank.
A.
Iron buildup in line to water conditioner.
B.
Iron buildup in water conditioner.
C.
Inlet of control plugged due to foreign material broken loose from pipes by recent work done on plumbing system.
5.
Loss of mineral through drain line.
A.
Air in water system.
B.
Clean control and add mineral bed.
Increase frequency of regeneration.
C.
Remove piston and clean control.
A.
Assure that well system has proper air eliminator control check for dry well condition.
B.
Check for proper drain rate.
B.
Improper sized drain line flow control.
A.
Fouled mineral bed.
A.
Check backwash, brine draw and brine tank fill. Increase frequency of regeneration. Increase backwash time.
A.
Clean flow control.
B.
Clean injector and screen.
C.
Replace timer.
D.
Replace brine valve seat and clean valve.
E.
Clean brine line flow control.
Page 26
Printed in U.S.A.
MODEL 2750 DOWNFLOW
Service Instructions (Cont’d.)
PROBLEM
8.
Softener fails to draw brine
9.
Control cycles continuously.
10. Drain flows continuously.
CAUSE CORRECTION
A.
Drain line flow control is plugged.
B.
Injector is plugged.
C.
Injector screen plugged.
D.
Line pressure is too low.
A.
Clean injector and replace screen.
B.
Clean injector.
C.
Clean screen.
D.
Increase line pressure to 20 P.S.I.
E.
Internal control leak.
E.
Change seals, spacers and piston assembly.
F.
Check drive motor and switches.
F.
Service adapter did not cycle.
A.
Missadjusted, broken or shorted switch.
A.
Determine if switch or timer is faulty and replace it, or replace complete power head.
A.
Valve is not programming correctly.
B.
C.
Foreign material in control.
Internal control leak.
A.
Check timer program and positioning of control. Replace power head assembly if not positioning properly.
B.
Remove power head assembly and inspect bore, remove foreign material and check control in various regeneration positions.
C.
Replace seals and piston assembly.
General Service Hints For Meter Control
Problem: Softener Delivers Hard Water.
Cause could be that. . . Reserve Capacity Has Been Exceeded.
Correction: Check salt dosage requirements and reset program wheel to provide additional reserve.
Cause could be that. . . Program Wheel Is Not Rotating With Meter Output
Correction: Pull cable out of meter cover and rotate manually. Program wheel must move without binding and clutch must give positive “clicks” when program wheel strikes regeneration stop. If it does not, replace timer.
Cause could be that. . . Meter Is Not Measuring Flow.
Correction: Check meter with meter checker.
Page 27
Printed in U.S.A.
MODEL 2750
System #4 - Typical Single Tank Installation with Optional Meter
MANUAL
SHUTOFF
3-WIRE
SERVICE
CORD
DRAIN
OPTIONAL
2750
METER
BRINE
LINE
RESIN
TANK
BRINE
TANK
Page 28
Printed in U.S.A.
MODEL 2750
System #5 Interlock - Typical Twin Tank Installation with
Optional 2 Meter Interlock and No Hard Water Bypass
DIAPHRAGM OPERATED VALVE
MANUAL SHUTOFF VALVE
ELECTRICAL
INTERLOCK
CORD
UNIT 2
2 tanks, 2 meters; interlock system. Both units in service at the same time. When one of the meters zero out, that unit starts into a regeneration. The other unit remains in service, even if it zeros out during this time.
PLUG
DRAIN
LINE
BRINE LINE
PRESSURE
SUPPLY
TO
S.V.O.
RESIN
TANK
LEAD
UNIT
BRINE TANK
Page 29
Printed in U.S.A.
MODEL 2750
System #6 - Twin Series Regeneration
Installation with a Remote Meter
DRAIN
LINE
METER
MANUAL SHUTOFF VALVE
UNIT 2
ELECTRICAL
INTERLOCK
CORD
PLUG
DRAIN
LINE
BRINE LINE
2 tanks, 1 meter, series regeneration system. Both units in service at the same time. When the meter zeroes out; the “lead” unit regenerates. Once the lead unit has returned to the service position, the
“lag” unit will regenerate.
RESIN TANK
LEAD UNIT
BRINE TANK
Page 30
Printed in U.S.A.
MODEL 2750
System #7 - Twin Alternator Installation
With a Remote Meter
MANUAL
SHUTOFF
VALVES
METER
3-WIRE
SERVICE
CORD
DRAIN
4-WAY
SOLENOID
VALVE
BRINE
VALVE
RESIN
TANK
BRINE
TANK
(OPTIONAL)
BRINE
TANK
ELECTRICAL
INTERLOCK
CORD
RESIN
TANK
DIAPHRAGM
OPERATED
VALVE
2 tanks, 1 meter; alternator system. One unit in service, the other is on standby. When the meter zero out; the unit in service goes into a regeneration cycle, the stand-by unit, goes into service.
Page 31
Printed in U.S.A.
MODEL 2750 DOWNFLOW
Service Assemblies
60029 1600 Brine Valve
For Illustration, See Page 12
1 . . . . . 10249 . . . . . . Brine Valve Spring
1 . . . . . 10250 . . . . . . Retaining Ring
2 . . . . . 10329 . . . . . . 3/8
″
Brass Nu
2 . . . . . 10330 . . . . . . 3/8
″
Ferrule
2 . . . . . 10332 . . . . . . 3/8
″
Sleeve
1 . . . . . 11749 . . . . . . B/V Stem Guide
1 . . . . . 11982 . . . . . . O-Ring Brine Valve
1 . . . . . 12552 . . . . . . 1600 Brine Valve Stem
1 . . . . . 12626 . . . . . . Shut-0ff Valve Seat
1 . . . . . 12748 . . . . . . Brine Valve Body
1 . . . . . 12550 . . . . . . Quad Ring
60034-XX 1700 Brine Valve,
Specify Refill Rate
For Illustration, See Page 11
1 . . . . . 10250 . . . . . . Brine Valve Spring
1 . . . . . 12550 . . . . . . Quad Ring
1 . . . . . 13201 . . . . . . Quad Ring
1 . . . . . 14785 . . . . . . Flow Control Retainer
1 . . . . . 14790 . . . . . . Brine Valve Body
1 . . . . . 14792 . . . . . . Brine Valve End Plug
1 . . . . . 14795 . . . . . . Brine Valve Piston
1 . . . . . 14797 . . . . . . Brine Valve Stem
1 . . . . . 14798 . . . . . . Spacer
2 . . . . . 14811 . . . . . . Piston Seal
1 . . . . . 15310 . . . . . . Brine Valve Spring
1 . . . . . 15517 . . . . . . Stem Guide
1 . . . . . 15414 . . . . . . Nut Ferrule 1/2
″
1 . . . . . 16123 . . . . . . Nut 1/2
″
1 . . . . . 16124 . . . . . . Ferrule 1/2
″
60080-XX 1600 Injector Assembly,
Specify Injector Size
For Illustration, See Page 8
1 . . . . . 10227 . . . . . . Injector Screen
1 . . . . . 11893 . . . . . . Injector Cap
1 . . . . . 10229 . . . . . . Injector Cover Gasket
1 . . . . . 10328 . . . . . . 90
°
Elbow 1/4
″
NPT x 3/8
″
Tube
2 . . . . . 10692 . . . . . . Screw
1 . . . . . 10913 . . . . . . Injector Nozzle
1 . . . . . 10914 . . . . . . Injector Throat
1 . . . . . 11475 . . . . . . Injector Body Gasket
1 . . . . . 17776 . . . . . . Injector Body
60381-XX 1700 Injector Assembly,
Specify Injector Size
For Illustration, See Page 8
1 . . . . . 11893 . . . . . . Injector Cap
1 . . . . . 10229 . . . . . . Injector Cover Gasket
1 . . . . . 17777 . . . . . . Injector Body
1 . . . . . 14801 . . . . . . Injector Nozzle
1 . . . . . 14802 . . . . . . Injector Throat
1 . . . . . 14803 . . . . . . Injector Screen
2 . . . . . 14804 . . . . . . Screw
1 . . . . . 14805 . . . . . . Injector Body Gasket
60090-HF 2750 Piston Assembly
For Illustration, See Page 8
1 . . . . . 10209 . . . . . . Quad Ring, -010
1 . . . . . 10234 . . . . . . O-Ring, -024
1 . . . . . 10598 . . . . . . End Plug Assembly
1 . . . . . 10909 . . . . . . Pin, Link
1 . . . . . 14451 . . . . . . Piston, 2750
1 . . . . . 14452 . . . . . . Piston Rod
60090-HF 2750 Piston Assembly
1 . . . . . 10598 . . . . . . End Plug Assy.
1 . . . . . 10909 . . . . . . Pin, Link
1 . . . . . 14451 . . . . . . Piston, 2750
1 . . . . . 14452 . . . . . . Piston Rod
60091-HF 2750 Piston Assy., Hot Water
1 . . . . . 10598-01 . . . End Plug Assy., Hot Water
1 . . . . . 14451 . . . . . . Piston 2750
1 . . . . . 14452 . . . . . . Piston Rod
1 . . . . . 10909 . . . . . . Pin, Link
60121 Seal & Spacer Kit, 2750
6 . . . . . 10545 . . . . . . Seal, Piston
1 . . . . . 10757 . . . . . . End Spacer
5 . . . . . 11451 . . . . . . Spacer,12 Hole
60122 Seal & Spacer Kit, 2750
Hot Water
6 . . . . . 10545 . . . . . . Seal, Piston
1 . . . . . 10757B . . . . . End Spacer
5 . . . . . 16589 . . . . . . Spacer, HW
Page 32
Printed in U.S.A.
MODEL 2750
Service Assemblies (Cont’d.)
60050-21 2750 Drive Assy., 120V
2 . . . . . .10218 . . . . . . Micro Switch
1 . . . . . .10250 . . . . . . Retaining Ring
2 . . . . . .10302 . . . . . . Insulator
2 . . . . . .10338 . . . . . . Pin, Roll 3/32 x 7/8
1 . . . . . .10621 . . . . . . Link
1 . . . . . .10769 . . . . . . Motor, Drive 1 20V
1 . . . . . .10774 . . . . . . Bracket, Motor Drive Side
5 . . . . . .10872 . . . . . . Screw, Hex Washer 8-32 x 5/16
1 . . . . . .11667 . . . . . . Wire Harness, Drive Motor
1 . . . . . .11826 . . . . . . Bracket, Sensor Motor
1 . . . . . .12576 . . . . . . Cam, Drive STF
1 . . . . . .12777 . . . . . . Cam, Shut-Off Valve
1 . . . . . .13366 . . . . . . Bearing, Drive
2 . . . . . .14923 . . . . . . Screw, Pan HD Mach 4-40 x 1
1 . . . . . .17904 . . . . . . Bushing, Heyco
60365-XX Brass DLFC 3/4
″
NPT
Specify Flow Rate
Range 1.2 - 7.0 GPM
6071 0-XX
60391
60392
60301
60303
60306
60307
BLFC, 1
″
Specify Flow Rate
Range 8.0 - 25.0 GPM
2750 Meter Assy., STD
2750 Meter Assy., EXT
3000 12 Day Timer, Specify
Voltage
3200 Clock Timer, Specify
Voltage
3210 Delay Timer, Specify
Voltage
3220 Immed Timer, Specify
Voltage
Printed in U.S.A.
Page 33
P/N 15512 Rev. 2 3/00 Printed XX/00
Advertisement