Sinclair Nordic Inverter ASH-09AIN PT, ASH-12AIN PT split-system air conditioner SERVICE MANUAL
The Sinclair Nordic Inverter ASH-09AIN PT and ASH-12AIN PT are part of the Nordic Inverter Series. They are designed to provide efficient and reliable cooling and heating in a variety of applications.
PDF
Download
Document
Advertisement
Advertisement
SERVICE MANUAL NORDIC INVERTER SERIES ASH-09AIN PT, ASH-12AIN PT 1 Summary and features Model ASH-09AIN PT ASH-12AIN PT Remark 2. Specifications and Technical Parameters ASH-09AIN(PT) Model Function Rated Voltage Rated Frequency Total Capacity (W/Btu/h) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m3/h) (H/M/L)** Dehumidifying Volume (l/h) EER / C.O.P (W/W) Energy Class Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (w) Input of Heater (w) Fan Motor Capacitor (uF) Fan Motor RLA(A) Fan Type-Piece Diameter-Length (mm) Evaporator Pipe Diameter (mm) Row-Fin Gap(mm) Indoor Coil length (l) x height (H) x unit coil width (L) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level dB (A) (H/M/L) Sound Power Level dB (A) (H/M/L)*** Dimension (W/H/D) ( mm) Dimension of Package (L/W/H) ( mm) Net Weight /Gross Weight (kg) COOLING HEATING 1Ph – 220-240V~ 50Hz 3000/2500 3200/2750 1350/780 1400/760 1400 1450 6.2 6.3 490 1.2 2.2/3.21 2.3 /3.61 / ASH-09AIN PT 1160 / 1010 / 890 14 None 1 0.14 Cross flow fan – 1 φ97---583 Aluminum fin-copper tube 7 2-1.4 580X228.6X25.4 MP28VA 2 PCB 3.15A Transformer 0.2A 42 / 39 / 36 49 / 45/ 42 770X190X250 855X272X330 8.5/12.5 Model of Outdoor Unit Compressor Manufacturer/trademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range (℃) Condenser Pipe Diameter (mm) Rows-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Fan Motor Speed (rpm) Output of Fan Motor (W) Outdoor Fan Motor RLA(A) unit Fan Motor Capacitor (uF) Air Flow Volume of Outdoor Unit Fan Type-Piece Fan Diameter (mm) Defrosting Method Climate Type Isolation Moisture Protection Permissible Excessive Operating Pressure for the Discharge Side(MPa) Permissible Excessive Operating Pressure for the Suction Side(MPa) Sound Pressure Level dB (A) (H/M/L) Sound Power Level dB (A) (H/M/L) Dimension (W/H/D) ( mm) Dimension of Package (L/W/H)( mm) Net Weight /Gross Weight (kg) Refrigerant Charge (kg) Length (m) Gas additional charge(g/m) Connec Outer Liquid Pipe (mm) tion Diameter Gas Pipe (mm) Pipe Max Height (m) Distance Length (m) ASH - 09AIN (PT) MITSUBISHI KNB092FHBMC rotary 25 3.89 895 None Capillary throttling Transducer starting -10℃≤T≤43℃ Aluminum fin-copper tube 9.52 1-1.6 The above data is subject to change without prior notice. 608X508X22 830±20 30 0.3 2.5 / Axial fan –1 400 Auto defrost T1 I IP24 3.8 1.2 53 63 848X260X540 878X360X590 35/40 R410A / 0.78 4 15 Φ6(1/4”) Φ9.52(3/8”) 5 10 Model Function Rated Voltage Rated Frequency Total Capacity (W/Btu/h) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m3/h) (H/M/L)** Dehumidifying Volume (l/h) EER / C.O.P (W/W) Energy Class Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (w) Input of Heater (w) Fan Motor Capacitor (uF) Fan Motor RLA(A) Fan Type-Piece Diameter-Length (mm) Evaporator Pipe Diameter (mm) Row-Fin Gap(mm) Indoor Coil length (l) x height (H) x unit coil width (L) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level dB (A) (H/M/L) Sound Power Level dB (A) (H/M/L)*** Dimension (W/H/D) ( mm) Dimension of Package (L/W/H) ( mm) Net Weight /Gross Weight (kg) ASH - 12AIN (PT) COOLING HEATING 1Ph – 220-240V~ 50Hz 4000/3500 4300/4000 1500/1090 1420/1108 1600 1650 7 7.2 550 1.6 2.67/3.21 3.01/3.61 A/A ASH-12AIN PT 1250/1100/1050 20 None 1 0.152 Cross flow fan φ92.1—616 Aluminum fin-copper tube 7 2-1.4 681×324.3×38.1 MP28EA 2 Controller3.15 transformer0.2 42 / 39 / 38 52 / 49 / 48 830×285×189 906×385×265 11/14 Model of Outdoor Unit Compressor Manufacturer/trademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range (℃) Condenser Pipe Diameter (mm) Rows-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Fan Motor Speed (rpm) Output of Fan Motor (W) Outdoor Fan Motor RLA(A) unit Fan Motor Capacitor (uF) Air Flow Volume of Outdoor Unit Fan Type-Piece Fan Diameter (mm) Defrosting Method Climate Type Isolation Moisture Protection Permissible Excessive Operating Pressure for the Discharge Side(MPa) Permissible Excessive Operating Pressure for the Suction Side(MPa) Sound Pressure Level dB (A) (H/M/L) Sound Power Level dB (A) (H/M/L) Dimension (W/H/D) ( mm) Dimension of Package (L/W/H)( mm) Net Weight /Gross Weight (kg) Refrigerant Charge (kg) Length (m) Gas additional charge(g/m) Connec Outer Liquid Pipe (mm) tion Diameter Gas Pipe (mm) Pipe Max Height (m) Distance Length (m) ASH - 12AIN (PT) MITSUBISHI KNB092FHBMC Double-rotor 33 3.92 960 Int11l-3979 Capillary throttling Transducer starting -10℃≤T≤43℃ Aluminum fin-copper tube 7 2-1.4 The above data is subject to change without prior notice. 608/498/22 880±20 30 0.3 2 / Axial fan-1 400 Auto defrost T1 I IP24 3.8 1.2 ≤55 ≤65 848X260X540 878X360X590 39/43 R410A / 1.17 4 15 Φ6(1/4”) Φ12(1/2”) 5 10 3 Component Name Air in Panel Display Indoor unit Louver Air out Zoom in the display Remote controller Heat Cool Auto Power/Run Fan Outdoor unit Power plug Drain hose Dehumidify Air in Connection pipe and connecting wire Air out 4 Overall and Installing Dimension Overall and Installing Dimension of Indoor Unit(9K) Air inlet grill Left Tube-exit hole Top View Rear View U U rear panel Right Tube-exit hole Unit: mm Overall and Installing Dimension of Indoor Unit(12K) Air inlet grill Left Tube-exit hole Top View Rear View U U rear panel Right Tube-exit hole Unit: mm Overall and Installing Dimension of Outdoor Unit Unit: Bolt Nut Wrench mm 5. Electrical Diagram ASH-09AIN PT ASH-12AIN PT 1 1 ,1'22581,7 287'22581,7 6 Manual of functions of remote controller and operation method Manual of functions of remote controller 6.1.1 Temperature parameter The room setting temperature(Tpreset) The room ambient temperature (Tamb) 6.1.2Basic Functions It will delay 3 minutes for restarting unit after compressor is stoped . Cooling Mode Cooling Conditions and Process When T amb.≥Tpreset , the unit will run under cooling mode, in which case the compressor \ indoor fan and outdoor fan will start , the indoor fan will run at setting speed. When T amb.≤Tpreset -2℃, the compressor will stop, the outdoor fan will atop running after 30 seconds,the indoor fan will run at setting speed. When Tpreset -2℃<T amb.< Tpreset +1℃, the unit will maintain its original operating status. Under this mode, the switchover valve will not be powered on, and the setting temperature range is16 ~30 . The air conditioner will adjust the running frequency of the compressor automatically according to the change of ambient temperature. Tpreset Tamb Start cooling Original operating status Tpreset -2℃ Stop cooling ≥3 min. Compressor Outdoor fan Indoor fan 6.1.2.1.2 Protection Antifreeze Protection Preset speed Stop Run When the antifreezing pretection is detected,the compressor will stop,the outdoor fan will stop after 30s , the indoor fan motor and swing fan motor will run at original run conditions under the cool mode.Indoor fan motor will run at low speed and indoor fan motor will run at oroginal conditions under the dehumidify mode.When ant -ifreezing protection is eliminated and the compressor has stopped for 3 minutes,the whole unit will run in the oroginal mode. During antifreeze protection Compressor 3 min. Outdoor fan Indoor fan Stop Run Overcurrent protection If total current is high,the compressor wil run in limited frequency.If total current is over the stop-running current,then the compressor will stop,the outdoor will delay 30 seconds to stop. 6.1.2.2 DRY Modes 6.1.2.2 .1 The conditions and process of DRY When T amb. > T preset, the ℃ unit will run under DRY mode, in which case the compressor \indoor fan and outdoor fan will be started and the indoor fan will run at low speed. When Tpreset -2<T amb<Tpreset , the unit will run with original setting. When Tamb.< Tpreset-2℃, the compressor will be stopped, and outdoor fan will be stopped after 30 seconds,the indoor fan will run at low speed. Under this mode, the switchover valve will not be powered on, and the setting temperature range is16 ~30 . The air conditioner will adjust the running frequency of the compressor automatically according to the change of ambient temperature. Tamb Dry Tpreset Original condition Tpreset -2℃ Stop Compressor Outdoor fan Indoor fan low speed Protection Run Protection function is the same with cool mode HEAT Mode Stop The conditions and process of heating When Tamb Tset +2 ,the system enters heating running, in this case, the reversal valve, compressor, out fan enter simultaneously running.The indoor fan will run with setting fan speed and anti-coolwind will be runned. When Tamb Tset +5 ,the compressor will stop, and outdoor fan will be stopped in 30 seconds,the indoor unit will run at setting fan speed for 60s then will stop .The switchover valve will be powered off after compressor is stopped for 2 minutes under heating-off mode or the condition that heat is changed to other modes When Tset+2 <Tamb<Tset+5 ,unit will keep the original operation status. Under this mode, the switchover valve will be powered on, and the setting temperature range is16 ~30 . The air conditioner will adjust the running frequency of the compressor automatically according to the change of ambient temperature. When the unit is turned off in HEAT mode, or switched to other mode from HEAT mode, the four-way valve will be powered off after the compressor stops. Stop running set set Original running state ambient a Start heating 3min Compressor Outdoor fan Indoor fan 2 min 2 min Reversal vavle Run Conditions and processes of defrost Stop When frost is detected in the condenser, the system will enter into defrosting state. When defrosting starts, the compressor and indoor fan will stop, and the outdoor fan and four-way valve will delay 30 seconds to stop. The compressor will start after 30 seconds and then defrosting will be started. When the compressor has run for 8 minutes , the compressor will stop After 30 seconds the four-way valve opens and afteranother 60 seconds, the compressor and outdoor fan resume running. The indoor fan will delay 2 minutes to run at the latest. Protection Overcurrent protection If total current is high,the compressor wil run in limited frequency.If total current is over the stop-running current,then the compressor will stop,the outdoor will delay 30 seconds to stop. Fan mode Under FAN mode,the indoor fan motor can choose high\middle\low\auto mode to run,compressor\outdoor fan motor and 4-way vavle will stop running. Under this mode, the range of setting tem. is 16-30 The air conditioner will adjust the running frequency of the compressor automatically according to the change of ambient temperature. Auto Mode Under this mode, the system will automatically select its run mode (cool, dehumidify, heat or fan) with the change of ambient temperature. For protection function, same as under cooling and heating mode.When the ambient temp. is changed, it prior to change mode. The air conditioner will adjust the running frequency of the compressor automatically according to the change of ambient temperature. Protection function in each mode Overload protection When tube temp. is detected high,the compressor runs in limited frequency or slow-frequency.When the temp. is over standard,then compressor stop running.In auto HEAT or HEAT mode,the indoor fan will blow for 60 seconds and then stop. In other modes,the indoor fan will run at the setting speed. Compressor discharge tempreture protection When the temp. is over the standard,then compressor stop running.When the discharge temp. resume the original conditions and compressorhas stop running for 3 minutes,the compressor will resume running. Communication mulfunction There have communication mulfunction when unit don't receive the correct signal for 3 minutes,the unit will stop running. Module protection When module is in protection,the compressor will stop.It will resume running after stopping for 3 minutes.During the period of module protection,there will display mulfunction in indoor unit,and the total unit will stop running. Other control ON/OFF The switch status is changed one time when pressing the ON/OFF key. Mode function Unit will choose and disolay the below mode when pressing mode key:AUTO,COOL DRY,FAN,HEAT,AUTO. TEMP. setting button Each time TEMP or TEMP button is pressed, the set temperature will be increased or decreased by 1℃ . Adjusting range is 16--30℃ . In AUTO mode, this button does not function. Auto key If controller is turned on,it will be stoped when pressing this key.If controller is turned off,unit will run with auto and swing is running when pressing this key. Timer control The unit is turned on or off according to the timer set by the remote controller. Sleep function When the air conditioner is in COOL or DRY mode, after Sleep mode has been set properly, the preset Tset will be increased by 1 after the sleep program has run for 1 hour, and Tset will be increased by another 1 after 2 hours. Tset has been increased by 2 totally in two hours. Then the unit will run at this set temperature and at the set speed. Tpreset Setting temp. Tpreset Tpreset 1hr. 2hrs. 2hrs. above When the air conditioner is in HEAT mode, after Sleep mode has been set properly, the preset Tset will be decreased by 1 after the sleep program has run for 1 hour, and Tset will be decreased by another 1 after 2 hours. Tset has been increased by 2 totally in two hours. Then the unit will run at this set temperature and at the set speed. 2hrs. 1hr. 2hrs. above Tpreset Tpreset Tpreset In FAN and AUTO mode, the set temperature is fixed. Setting temp. Tpreset Indoor fan control Use the remote controller to set the indoor fan running at HIGH, MED or LOW speed.At this time the fan will run at high, medium or low speed. It can also be set to AUTO. During switch in each fan speed, there should be 30s at least delay. (8) Power supply for outdoor unit The power supply for outdoor unit is turned on in AUTO, COOL, HEAT and DRY mode under turn-on state. The power supply for outdoor unit will delay 3 minutes to turn off under turn-off state or in the FAN mode under turn-on state. Swing control Use the SWING button of the wireless remote controller to controller SWING On and Off. Swing will only act when indoor fan is running.After power on, the stepping motor turns back to 0 position and closes the air outlet vent; after the unit is in cool mode,it will turn back to the max. air outlet D1 position,then swing back to L position for the next order;When unit is in Heat mode,quide louver stop at D1 position;If the unit is under swing mode,it will swing betewwn L1 and D1 position.When unit is turned off,it will turn back to Buzzer The controller is powered on and detect the signal received, the buzzer will beep. Memory function Memory contents of power off: Mode, Swing, Set temp., Set fan speed, Timer ect; when unit is turned On, when repowered on, there should be 3 minutes above then can supply power to outdoor unit; when unit is off, when repowered on, the indoor unit can supply power to outdoor unit at once. Compressor delay protection In Cool, Dry, Heat modes, every start of compressor there should be 3 minutes delay. Outdoor unit malfunction display Malfunction Compressor opened 5 6 7 8 9 10 11 12 13 14 15 16 17 Red Yellow Green Blink once Defrosting Blink twice Anti-freezing protection Blink three times IPM protection Over current protection Overload unit stop protection Air exhaust unit stop protection Blink 4 times Blink 5 times Blink 6 times Blink 7 times Compressor overload Blink 8 times protection Limit requency (currency) Blink once Frequency declined Blink twice (Air exhasut) Frequency limit Blink 3 times (Overload) Frequency declined Blink 4 times (anti-freezing) Outdoor tube temp Blink 5 times sensor malfunction Outdoor ambient temp Blink 6 times sensor malfunction Blink 7 times Outdoor air exhaust temp sensor malfunction Arrive at temp. of Blink 8 times unit on Communication is normal Normal 7 Disassembly procedures Disassembly procedures for indoor unit of unit 9KK Operation procedures/pictures Disassembling the front panel and filters Unloose the clasps on both sides and lift the panel upward. Unplug the two connecting terminals of the display and slide out the rear clasp from the groove to take off the front panel.Push the filter upward,loosen the clasps,then you can pull out the filters Panel Filter Disassemble Guide Louver Manually bend the guide louver to loose the clasp at the guide louver. Remove the guide louver. Guide Louver Disassemble Front Case Open the three screw covers at the front case, unscrew the three screws, pull open the clasp at the front case, and remove the front case. Screw cover Screw Screws Connecting terminal Operating Procedures / Photos Disassemble Electric Box Cover Lossen three clasos, then remove the electric box cover Electric Box Cover Disassemble Water Tray Pull open the holding clasp on the left side of the water tray, disconnect the terminal of the stepping motor, lift and pull out the drainage pipe, and remove the water tray. Water Tray Clasp Terminal Disassembling the electric box Screw off the two pieces of screws that fix the electric box and unloose the clasp. Pull out the tube sensor, unloose the grounding nut and unplug the motor connecting terminal take out the electric box. Tube sensor Screw Grounding nut Motor connecting terminal Clasp Operating Procedures / Photos Disassemble Evaporator Unscrew the screw to remove the rear pipe clamp. Remove the left and right screws at the evaporator, manually move the evaporator to loosen the clasp of its side plate from the groove. Carefully take out the evaporator and pay attention to protect the connecting pipe. Screw Screw Disassemble Motor Unscrew the three screws fixing the motor clamp, Screw and remove the motor clamp. Motor Clamp Loosen the holding nut at the shaft sleeve on the right side of the cross flow fan. Slightly lift and then pull out the motor. Tighten nut Disassembling the cross flow fan Refer to the above steps to take out the cross flow fan from the base plate after taking out the motor. Fixing nut Disassembly procedures for indoor unit of unit 12k Operation procedures/pictures Disassembling the front panel and electric box cover Unloose the clasps on both sides and lift the panel upward. Unplug the two connecting terminals of the display and slide out the rear clasp from the groove to take off the front panel. Screw off the fixing screws of the electric box cover and open the electric box top cover to take it off. Panel Connecting Screws Cover of electric box terminal Disassemble Filter Push the filter upward,loosen the clasps,then can remove two pieces of filters Filter Disassemble Guide Louver Manually bend the guide louver to loose the clasp at the guide louver. Remove the guide louver. Guide Louver 8.1.4 4.Disassembling the front panel body Unclench the 3 screw covers and screw off the 4 pieces of screws that fix the panel body. Unloose the front and rear clasp to take off the panel body. Screw 8.1.5 5.Disassembling the electric box cover Unloose the 3 clasps to take off the electric box cover. 8.1.6 Clasp 6.Disassembling the water-tray assy Unloose the clasp on the left side and unplug the connecting terminal of the stepping motor. Be careful because the drainage pipe is placed here. Screw Disassemble Electric Box Remove the screw fixing the electric box, Tube sensor Grounding screw disconnect the terminal of connecting line, loosen the clasps and grounding screws, remove the tube sensor,then take out the electric box. Terminal Screw Disassemble Evaporator Unscrew the screw to remove the rear pipe clamp. Rear pipe Remove the left and right screws at the evaporator, clamp manually move the evaporator to loosen the clasp of its side plate from the groove. Carefully take out the evaporator Screw and pay attention to protect the connecting pipe. Screw Screw Operating Procedures / Photos Disassemble Motor Unscrew the 4 screws fixing the motor clamp, and remove the motor clamp. Right motor Clamp Bearing seat Loosen the holding nut at the shaft sleeve on the right side of the cross flow fan. Slightly lift and then pull out the motor. Screw Screw Left motor Clamp Motor Holding Screw Screw Disassembling the cross flow fan Refer to the above steps to take out the cross flow fan from the base plate after taking out the motor. Disassembly Procedure of Outdoor Unit 1.Disassemble Big Handle Unscrew the screw fixing the big handle,and then remove it downwards to take it out. Screw 2.Disassemble Top Cover Unscrew the 2 screws fixing left side of top cover and the 1 screw fixing the right side to remove the Screw top cover. 3.Disassemble Rear Grill Unscrew the 4 screws fixing the rear grill to Rear Grill remove it. Screw Big Handle Operating Procedures / Photos 4.Disassemble Front Panel Unscrew the 5 screws fixing the panel and dextrorotate the front panel to pull it out from groove. Screws 5.Disassemble Right Side Plate Unscrew the 2 screws fixing electric box ,and then unscrew the 5 screws fixing the right side plate to remove it. Screws Right Side Plate Screws 6.Disassemble Electric Box Unscrew the screws fixing the electric box, and then Screw pull out the inset block of lead-out wire of compressor and fan motor to take out the electric box. Electric Box 24 Operating Procedures / Photos 7.Disassemble Axial Flow Fan Loosen the fastening nut fixing the axial flow fan with Axial Flow Fan a spanner ,and then take out the nut,spring gasket and flap gasket in turn. Nut 8.Disassemble Motor and Motor Support Unscrew the 4 screws fixing the motor to take out the motor,and then unscrew the 2 screws fixing the motor support to take it out. Screws Motor Screw 9.Disassemble Four-way Valve Unscrew the fastening nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. (Note:Refrigerant should be discharged firstly.) Welding process should be as quick as possible and Four-way valve Four-way valve coil keep wrapping cotton wet all the time. Be sure not to burn out the lead-out wire of compressor. Weld spots 25 Operating Procedures / Photos 10. Disassemble Capillary Respectively unsolder the weld spots of main capillary and auxiliary capillary to take off the capillary. Capillary 11.Disassemble Gas and Liquid Valves Unscrew the two bolts fixing gas valve and liquid valve.Unsolder weld spots between gas valve and and air-return pipe to remove the gas valve. Unscrew the two bolts fixing liquid valve. Unsolder weld spots between liquid valve and capillary to Liquid Valve remove the liquid valve. (Note:During unsoldering ,wrap the valves with wet cloth to avoid damage for high temperature.) Bolts Gas Valve 12.Disassemble Compressor Unscrew the three foot-nuts at the foot of the compressor. Unsolder the suction and the discharge pipes of the compressor,and then carefully remove the pipes to take out the compressor. Weld spots Nuts with washers 26 8 Exploded View of Components and Parts of Indoor Unit ASH-09AIN PT No Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Wall-Mounting Frame Rear Case Evaporator Assy Cross Flow Fan Ring of Bearing Fan Bearing Drainage Pipe Water Tray Swing Louver Swing Linkage 1 Swing Linkage 2 Front Case Screw Cover Filter Remote Control Y612C-B Decorate Piece Receiver Board Front Panel Guide Louver 2 Guide Louver 1 Motor MP28VA Motor Clamp A Motor FN14A Electric Box Cover Terminal Board T4B3A Covering Plate Electric Box Main PCB 9M82 Transformer 48X26G Wire Clamp Rear Clamp Connecting Cable Power Cord Room Sensor 15K Tube Sensor 20K swing louver clamp swing louver swing louver(up) swing louver(down) Part Code ASH-09AIN 01252220 222020016 0100209319 10352001 76512203 / 0523001401 201820272 10512080 10582002 10582003 200022105 242520062 11122002 30511005 68012019 30545702 200022092 105120342 105120332 15212110 26112014 150121081 22242030 42011233 201220061 20102178 30039046 43110233 71010103 24242001 400205235 400204643 390000451 390000591 10582409 10582408 10542004 10542005 The above data is subject to change without prior notice. Qty 1 1 1 1 1 1 1 1 1 1 1 1 3 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Exploded View of Components and Parts of Indoor Unit ASH-12AIN PT No Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Wall-Mounting Frame Rear Case Evaporator Assy Cross Flow Fan Ring of Bearing Fan Bearing Drainage Pipe Water Tray Swing Louver Swing Linkage Front Case Screw Cover Filter Remote Control YB1B4 Front Panel Decorate Piece Receiver Board Guide Louver Guide Louver Motor MP28VA Motor Left Clamp Motor Right Clamp Motor FN20G Electric Box Cover Terminal Board T4B3A Covering Plate Electric Box Main PCB 9H82 Transformer 57X25C Wire Clamp Rear Clamp Connecting Cable Power Cord Room Sensor 15K Tube Sensor 20K Part Code ASH-12AIN PT 01252384 22202050 010020212 10352005 76712015 76512210 0523001401 201820394 105120413 10582439 200022956 24252007 11122440 30511005 200022921 68012019 30545558 261120432 261120422 15212105 261124281 26112429 15012058 22242017 42011233 20102123 20102108 30039085 43110237 71010003 26112425 40020538 400204643 390000451 390000591 The above data is subject to change without prior notice. Qty 1 1 1 1 1 1 1 1 1 1 1 3 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Components and Parts List of Outdoor Unit(2) ASH-09AIN PT and ASH-12AIN PT No Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Front Panel Clap Board Heating cable (chassis) Reactor Box PFC Inductance 0.8mH/20A Drainage Connecter Reactor Support Overload Protector Compressor Heating cable Compressor Gasket Bolt Nut Valve Support Right Side Plate Valve Valve Capillary Assy One Way Valve 4-Way Valve 4-way Rever-sing Valve Component Big Handle 4-way Valve Coil Wire Clap Insulation Piece D Terminal Board A Electric Box 2 Electric Box PCB Temperature Sensor Sensor 20K Exhaust Gas Temperature Sensor 50K Electric Box Cover Rectifier S25VB60 Sensor Insert Radiator Rear Grill Condenser Assy Top Cover Assy Motor Support Motor Axial Flow Fan Nut Front Grill 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 Part Code ASH-09AION PT ASH-12AIN PT Qty 01533005 01233012 / 01403617 / 06123401 01203682P / 00120228 76513004 / 70210108 70310011 01713041 0130200401 07100003 07100005 0310333305 / 430004022 01533005 01233012 76510004 01413504 99070120 06123401 0120352402 00183003 00120228 76513004 76710236 70210108 70310013 01713041 01303048 07100006 07100003 031030716 071301025 430004032 1 1 1 1 1 1 1 1 1 1 3 3 3 1 1 1 1 1 1 1 03123042 03123013 1 26233433 430004002 71010003 70410525 42011113 01403998 20113005 301380021 39000208 390001921 26233433 430004002 71010003 70410525 42011113 01413116 20113005 30039155 39000208 39000071 1 1 1 1 1 1 1 1 1 1 39000016 39000016 1 01413048 / 42020063 49010065 01473023 0110359012 01253261 01705002 150130671 10333414 70310131 22413431 01413048 46010602 42020063 49010213 01473030 0111308202 01253261 017030531 15013067 10333004 70310131 22413431 1 1 1 1 1 1 1 1 1 1 1 1 9 Failure and analysis Analysis in this section is used for Linge Wind D.C. Inverter Series. Before analysis, you can diagnose according to the indicator display on outdoor unit. The breaker trips at once when it Measure insulation resistance to ground to see if there is any leakage. is set to "ON". Trip of breaker or blow of fuse The circuit or the part of the air conditioner has malfunction. They heat and break the insulation The breaker trips in few minutes when it is set to "ON" and lead to short circuit or creepage. Measure the insulation resistance or eliminate the malfunction one by one. If the breaker itself has Air conditioner can not start up malfunction, then replace the breaker. No power Check power supply circuit. Power plug is not well plugged in and poor connection Check if the plug is properly plugged in and make the loose contact firm. The air conditioner does not react after it is powered ( after Fuse of controller burnt out Change controller fuse the plug is inserted, the buzzer does The transformer connection is loose or has bad not sound and the contact or the transformer has malfunction Fasten the wiring; measure the output voltage of the transformer, if it is incorrect, change the transformer remote startup has no response) The remote controller Controller is broken Check remote controller Remote controller is short of power Change batteries Remote controller malfunction First, press the manual switch button AUTO, does not receive signals (after it is if there is no response,check based on the powered, the buzzer above methods. If it runs normally after will sound, unless it has Receiver loose or poor connection pressing the button,check again whether the installation position and the connection wire malfunction) of the reception head is correct. If it is correct,then replace the receiver or the re- Receiver is broken mote controller. heck the voltage. If it is lower than 10£¥ of the rated voltage, check the Power voltage is too low cause, improve the power supply condition and add the stabilized voltage power supply. Controller malfunction (IC2003 broken, creepage of parallel capacitor of relay loop, relay is broken etc.) In cool, heat mode,the outdoor unit and compressor will not run. Change controller Wire loose or wrong connection Correctly wire according to the drawing Improper setting of temperature Adjust setting temp. Improper set of temperature Adjust set temperature If cooling (heating) load is proper Check the forecasted load of cooling (heating) The refrigerant has leakage or is insufficient Malfunction of refrigerant flow Leakage between the high pressure and the low pressure inside the compressor Malfunction of four-way valve Poor COOL(HEAT) operation Local block of capillary Blockage of cooling system Heat insulation for the connection pipes of the indoor unit and the outdoor unit is bad. heck and fill the leakage, then vacuumize it and supplement the refrigerant as required Replace the compressor Replace the four-way valve Replace the capillary Judge whether the system is blocked by observing the condensation of evaporator and the pressure value of the high pressure manometer and take measures to deal with the system. Make sure that heat insulation for the thick and thin pipes is good. Heat insulation must also be provided for the joint andthe exposed part of the copper pipe . Block of outdoor heat exchanger Clean the dust accumulated on the surface of the heat exchanger. Air filter were blocked Clean the filter Fan speed was set too slow Air circulation is insufficient Fan rotation speed becomes low The installation position of the outdoor unit is not appropriate. The outdoor temperature is too high. The air tightness is not enough. People come in and out too frequently. There are heating devices indoors. To set the fan speed to high or middle speed Capacitor damage Replace the capacitor Motor damage Replace the motor Good ventilation must be provided for the installation position of the outdoor unit. Properly install the rainproof plate or the sunproof plate. If the maximum cool air still can not meet the requirement, it is suggested to replace the air conditioner. Keep certain air tightness indoors, try not to use electricalappliance with large quantity of heat The indoor fan motor is burned or breaks or has the heat protector malfunction. The fan does not run when it is set to supply air. In the cooling and heating mode, the compressor runs, but the outdoor fan does not run. The compressor is too hot and leads to the action of the protector. The built-in heat protector of the motor breaks frequently because the motor is abnormal. Replace the fan motor Wrong connection Make the correction connection based on the circuit drawing. The fan capacitor has open circuit or is damaged. Replace the fan capacitor of the same type and same specification. The outdoor fan motor is damaged. Replace the fan motor Wrong connection Make the correct connection based on the circuit drawing The outdoor fan capacitor is damaged. Replace the fan capacitor Malfunction of compressor Replace the compressor Breakage of running capacitor of compressor Replace the capacitor The voltage is too low or too high. Manostat is recommended. Wrong wire connection Connect the circuit diagram correctly The protector itself has malfunction. The refrigerant is not enough or is too much. The compressor is too hot and leads to the action of the protector. Replace the fan motor or the defective part. The capillary is blocked and the temperature rises. The compressor does not run smoothly or is stuck. The air discharge valve is damaged The protector itself has malfunction. Use the multimeter to check whether the contact of the compressor is on when it is not overheated. If it is not on, then replace the protector Adjust the volume of the refrigerant Replace the capillary Replace the compressor Replace the protector The torque of the swing motor is not enough The swing fan does not run. Wrong connection The controller is damaged(IC2003 is damaged, the swing relay can not close, etc) First, check whether the connection is wrong. If no, replace the parts Drainage pipe blocked or broken Change drainage pipe Water leakage Wrap of refrigerant pipe joint is not close enough. Re-wrap and make it tight. Fan of indoor unit contacts other parts. Adjust fan location. Foreign object in indoor unit Take out the foreign object. Compressor shakes too much. Adjust support washer of compressor, and tighten loosen screws. Touch of pipeline of outdoor unit Separate the touching pipeline. Touch of inner plates 1. Tighten connect screw. Abnormal sound and shake 2. Stick absorbing clay between plates. Louver of outdoor unit touched outer case. Adjust location of louver. Abnormal sound inside compressor Change compressor Abnormal solenoid sound from 4-way valve when heating Circuit-short inside solenoid of the valve and change the solenoid valve. There are no heating malfunctions in the above for the cooling only unit. Note: 1. When maintaining, before detecting the voltage between the modular PN is less than 50V, please never touch any of the terminals, in order to avoid electric shock. 2. When replacing the batteries, commutating bridge, both of them should be coated with the coolant. Malfunction display section Trendy D.C. Inverter Series When malfunction or protection occurs in the air conditioner,the indicator of outdoor unit will blink accordingly as well. When protection or malfunction is eliminated, display will be back to normal Indicator display of outdoor unit Yellow light blinks 1 time Yellow light blinks 2 times Yellow light blinks 3 times Indicator display of outdoor unit Compressor is running (this is normal condition and the display of indoor unit is normal) Defrosting (Normal display) Antifreezing protection (display of indoor unit is normal Yellow light blinks 4 times IPM module protection Yellow light blinks 5 times Overcurrent protection Yellow light blinks 6 times Overload protection Yellow light blinks 7 times Discharge protection Yellow light blinks 8 times Compressor overload protection Red light blinks 1 time Limit frequency (currency) Red light blinks 2 times Frequency declined (air exhaust) Red light blinks 3 times Limit frequency (overload) Red light blinks 4 times Frequency declined (air exhaust) Red light blinks 5 times Malfunction of outdoor condenser sensor Red light blinks 6 times Malfunction of outdoor environmental sensor Red light blinks 7 times Malfunction of outdoor discharge sensor Red light blinks 8 times Starting temperature is reached Green light does not blink Communication malfunction Analysis or handling of some of the malfunction display: Compressor discharge protection Possible reasons: shortage of refrigerant; blockage of air filter; poor ventilation or air flow short pass for condenser; the system has noncondensing gas (such as air, water etc.); blockage of capillary assy (including filter); leakage inside four-way valve causes incorrect operation; malfunction of compressor; malfunction of protection relay; malfunction of discharge sensor; outdoor temperature too high. Handling method: refer to the malfunction analysis in the above section. Low voltage overcurrent protection Possible reason: Sudden drop of supply voltage. Communication malfunction Handling method: Check if communication signal cable is connected reliably Sensor open or short circuit Handling method: Check whether sensor is normal, connected with the corresponding position on the controller and if damage of lead wire is found Compressor overload protectio Possible reasons: shortage of refrigerant; blockage of capillary and increase of suction temperature; improper running of compressor, burning in or stuck of bearing, damage of discharge valve; malfunction of protector. Handling method: adjust refrigerant amount; replace the capillary; replace the compressor; use universal meter to check if the contactor of compressor is fine when it is not overheated, if not replace the protector. System malfunction i.e. overload protection. When tube temperature (Check the temperature of outdoor heat exchanger when cooling and check the temperature of indoor heat exchanger when heating) is too high,protection will be activated. Possible reasons: Outdoor temperature is too high when cooling; insufficient outdoor air circulation; please refer to the malfunction analysis in the previous section for handling method for refrigerant flow. IPM module protection Processing method:Once the module malfunction happens,if it persists for a long time and can not be self- canceled, cut off the power and turn off the unit,and then re-energize the unit again after about 10 min.After repeating the procedure for sever times, if the malfunction still exists,replace the module.(refer to the next page) Check if the voltage between power module P and N is too low, if the current is too high.In normal condition, voltage between P and N should be 310V. Check power supply circuit of outdoor unit Check if radiating paste is spread evenly or radiating sticker is stuck well; if screws of power module is tightened Temperature of power module is too high, which causes overheating protection Protection is still displayed Reinstall power module and re-spread radiating paste or stick radiating sticker on the radiator of power module. Confirm the setting status of outdoor unit (cooling) Normal Poor radiation, heat exchanger is dirty Remove obstructions and clean Confirm if outdoor fan motor is running; unplug the three connecting wires between U, V, W of Outdoor fan Confirm if there is voltage output and balance of compressor and power module. Turn on the unit to see runs voltage between any two phases of U, V and W. if outdoor fan runs normally (more than 3 minutes) Outdoor fan stops No Yes Measure the voltage of outdoor fan connector No voltage Replace the mainboard of outdoor unit Whether module type is correct Normal voltage Replace the fan motor Replace module Measure the three-phase resistance of compressor Normal Whether cylinder of compressor is stuck If the unit runs normally after connected with the new compressor for trial run, the cylinder of original compressor is stuck — — power Normal Abnormal Replace the module with correct type the Abnormal Replace the compressor Name of malfunction Display of indoor unit ERROR CODE State of the lamps on the outdoor unit PCB GREEN-LED2 RED-LED3 YELLOW-LED4 blink 4 times Reasons Stop for anti-freezing protection of indoor unit E2 blink 3 times refrigerant leakage, indoor unit airflow blocked up, filter duty Stop for exhaust protection E4 blink 7 times less refrigerant, capillary blocked up, ambient temperature is unsuitable Stop for low voltage protection E5 blink 5 times low voltage, ambient temperature is unsuitable Stop for communication malfunction E6 Stop for compressor overload protection H3 blink 8 times compressor shell oer heat, less refrigerant, capillary blocked up Overload protection H4 blink 6 times ambient temperature is unsuitable, heat exhanger blocked up Stop for IPM module protection H5 blink 4 times IPM modul over heat, low voltage, silica gel Indoor ambient temperature sensor malfunction F1 terminal connect not reliable, temperature sensor malfunction Indoor tube temperature sensor malfunction F2 terminal connect not reliable, temperature sensor malfunction Outdoor ambient temperature sensor malfunction F3 blink 6 times terminal connect not reliable, temperature sensor malfunction Outdoor tube temperature sensor malfunction F4 blink 5 times terminal connect not reliable, temperature sensor malfunction Outdoor exhaust temperature sensor malfunction F5 blink 7 times Automatic defrosting H1 REMARK: don´t blink communication line failure, main PCB failure, interfere source, connect line wrong terminal connect not reliable, temperature sensor malfunction blink 2 times H1 isn´t an error code, it´s a normal operation. Just heat pump has this function. 1. Error codes can only be seen in the type which has the temperature display PCB. If some type hasn´t this function, the lamps on the outdoor PCB are available then. 2. Normally, the communication between indoor unit and outdoor unit is successful, the green lamp (Led2) of outdoor PCB blinks 1sec. on, 1sec. off. 3. The red and yellow lamp blinks 0.5 sec. on, 0.5 sec. off, between two error display cycle, it will be 2 sec. off. 4. Led1 (red) is power lamp. Led3 (red) blinks 8 times which means temperature be up to machine run. When compressor starts, Led4 (yellow) blinks 1 times. ">
Advertisement
Key Features
- Inverter technology
- Cooling and heating modes
- Multiple fan speeds
- Auto mode
- Dehumidifying function
- Remote control
- Sleep mode
- Timer function
Frequently Answers and Questions
What are the cooling capacities of the ASH-09AIN PT and ASH-12AIN PT models?
The ASH-09AIN PT has a cooling capacity of 3000W (2500 Btu/h) while the ASH-12AIN PT has a capacity of 4000W (3500 Btu/h).
What is the operating voltage and frequency of the ASH-09AIN PT and ASH-12AIN PT models?
The ASH-09AIN PT and ASH-12AIN PT models operate on a single-phase 220-240V~ supply and have a rated frequency of 50Hz.
What types of compressors are used in the ASH-09AIN PT and ASH-12AIN PT models?
Both models use a rotary compressor manufactured by Mitsubishi.
What is the refrigerant used in the ASH-09AIN PT and ASH-12AIN PT models?
The ASH-09AIN PT and ASH-12AIN PT models use R410A refrigerant.