SOLAREG II VISION solar-thermal system controllers Installation and Service Manual
SOLAREG II VISION is a powerful microprocessor-controlled control appliance for the function-control of solar thermal systems. It regulates perfectly thermal solar systems with up to 2 collectors or 2 storage tanks and may be used for five system types.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
32
INSTALLATION AND SERVICE MANUAL microprocessor-controlled system controller for solar-thermal systems: SOLAREG II VISION IMPORTANT! PLEASE, READ CAREFULLY THIS MANUAL BEFORE INSTALLATION AND USE OF THE APPLIANCE! NON-COMPLIANCE CAN RESULT IN GUARANTEE EXCLUSION! KEEP THE MANUAL SAFE! The described appliance has been made and tested in compliance with CE-guidelines. 1 2 Symbols and short descriptions.......................................................................................3 Range of application / characteristic features.................................................................4 2.1 2.2 2.3 3 4 Range of application ............................................................................................................. 4 Appliance characteristic features ........................................................................................ 4 System types for SOLAREG II VISION ................................................................................. 5 Safety instructions .............................................................................................................6 Appliance installation ........................................................................................................7 4.1 4.2 5 Opening of the appliance ..................................................................................................... 7 Wall installation..................................................................................................................... 7 Electrical connection - overview.......................................................................................8 5.1 230V-connections ......................................................................................................... 9 5.1.1 5.2 5.2.1 5.2.2 6 Overview: 230V-connections for SOLAREG II.....................................................................................10 Connection temperature sensor ........................................................................................ 10 Overview: sensor connections for SOLAREG II...................................................................................11 Overvoltage protector module..............................................................................................................11 Operation / Display...........................................................................................................12 6.1 6.2 6.3 6.4 6.5 7 Overview of display and operating elements.................................................................... 12 Display – maximal display .................................................................................................. 13 Explanation of graphic symbols ........................................................................................ 13 Button function ................................................................................................................... 15 Exemplary appliance operation.......................................................................................... 16 Operating menu................................................................................................................17 7.1 Overview: Construction of menu structure....................................................................... 18 7.2 Menu „Info“ 7.3 Menu „Programming“ 7.4 Menu „Manual operation“ ............................................................................................ 20 7.5 Menu „Basic adjustment“ ............................................................................................ 21 8 ................................................................................................................... 19 .................................................................................................. 20 Controller functions .........................................................................................................22 8.1 General controller functions .............................................................................................. 22 8.1.1 8.1.2 8.1.3 8.1.4 8.1.5 8.1.6 8.2 System monitoring.............................................................................................................. 25 8.2.1 8.2.2 8.2.3 8.2.4 8.3 Sensor monitoring ................................................................................................................................25 Flow monitoring....................................................................................................................................25 Collector protection function / recooling ...............................................................................................26 System protection function...................................................................................................................26 Additional functions............................................................................................................ 27 8.3.1 8.3.2 9 Storage tank charge.............................................................................................................................22 Rotational speed regulation..................................................................................................................23 Cooling function ...................................................................................................................................23 Thermostat function (reheating)...........................................................................................................24 nd 2 temperature differential regulation..................................................................................................24 Tube collector function .........................................................................................................................25 Energy productivity measurement........................................................................................................27 Operating hours meter .........................................................................................................................27 Failure repair ....................................................................................................................28 9.1 9.2 10 11 12 13 14 Failures with error message............................................................................................... 28 Failures without error message ......................................................................................... 29 Technical data SOLAREG II .........................................................................................30 Resistance table PT1000..............................................................................................30 Table typical - current adjustments ............................................................................31 Terms of guarantee ......................................................................................................32 Declaration of conformity ............................................................................................32 1 SYMBOLS AN D S H O R T D E S C R I P T I O N S Explanation of graphic symbols used in the service manual: Attention! Symbol points out possible dangers and mistakes Attention 230V-voltage! Symbol points out the dangers through highly dangerous voltages. • Enumeration Please, pay attention! i Information for operation / characteristic features Realisation / procedure ? Testing / checking Often used abbreviations In the following descriptions and in the controller display abbreviations or short symbols are partly used for simplification rea- sons. Their meaning is presented in the following table. Abbr. Tcoll Tst 1/2 Tret Tth Meaning Temperature collector [°C] Temperature storage tank [°C] Collector return temperature [°C] Temperature for thermostat [°C] Abbr. min max > K Tfr xxx h Temperature antifreeze Any display value Operating hours °C dT kWh Meaning Minimal value Maximal value bigger than Kelvin Grade, corresponds to 1 grade temperature difference Celsius Grade Temperature difference Energy productivity in kWh Tip: Put the enclosed with the appliance „Quick-Info“ into the pocket provided on the back of the appliance to have always at hand an overview of all most important functions. SOLAREG II VISION Installation and service manual 2 R AN G E O F AP P L I C AT I O N F E AT U R E S / C H AR AC T E R I S T I C 2.1 Range of application The solar thermal controllers SOLAREG II VISION are powerful microprocessorcontrolled control appliances for functioncontrol of solar thermal systems. SOLAREG II VISION regulates perfectly thermal solar systems with up to 2 collectors or 2 storage tanks and may be used for five system types. Controllers are planned for use in dry spaces, in residential, business and industrial areas. Wrong use has to be checked before starting by means of valid regulations. 2.2 Appliance characteristic features The series SOLAREG II is provided with the following outfit features: • Intuitive, menu-conducted operation with graphic symbols and four operating keys. • Temperature differential regulation digitally adjustable regulation values • Rotational speed control or switch control of solar circulation pump. tivity measuring set (accessories) measures the energy obtained by a solar system. • Storing of all adjusted values even in the case of any longer mains voltage breakdown. • Various protective functions, as e.g. system protection, collector protection, recooling and antifreeze • Special function for systems with tube collectors • The third switch output for alternative nd choice of cooling function, heating or 2 temperature differential regulation • Integrated operating hour meter for storage tank charging • Large wiring space • Extensive functions for system monitoring with error and failure display through symbols Available accessories: • Integrated energy productivity measurement which by means of the produc- • Flow transmitter for productivity measurement Service manual for SOLAREG II VISION 4 • Temperature sensor PT1000 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 2.3 System types for SOLAREG II VISION Tip: the following system plans are no complete hydraulic wiring diagrams TYPE 0: 1 collector, 1 storage tank TYPE 1: 1 collector, 2 storage tanks pump-valve TYPE 2: 1 collector, 2 storage tanks with 2 pumps TYPE 3: 2 collectors, 1 storage tank pump-valve TYPE 4: 2 collectors, 1 storage tank with 2 pumps Tcoll P Temperature measuring collector Temperature measuring thermostat Temperature measuring collector return Temperature measuring storage tank Pump FM Flow meter Tth Tret Tst Service manual for SOLAREG II VISION 5 point point point point 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 3 S AF E T Y INSTRUCTIONS All installation and wiring work at the controller must be carried out only in an idle condition. The connection and starting of SOLAREG II must be carried out only by a competent staff. While doing this you have to keep to valid safety regulations, above all VDE 0100. Disconnect the appliance from operating voltage completely before any installation or wiring work at the electrical operating material. Never mix-up the connections of protective low voltage area (sensor, flow transmitter) with 230V-connections. Destruction and extremely dangerous voltage on the appliance and on the connected sensors and other appliances is possible. Solar systems can absorb high temperatures. There is a danger of burning! Be careful during installation of the temperature sensor! Mount SOLAREG II so that not to cause inadmissible operating temperatures (>50°C) for the appliance e.g. through sources of heat. Service manual for SOLAREG II VISION 6 SOLAREG II is neither splash-proof nor drip-proof. And so mount it in a dry place. For safety’s sake the system can remain in a hand mode only for test purposes. In this operating mode neither maximal temperatures nor sensor functions are monitored. If any damage on the controller, the cable or connected pumps and valves have been detected, the system must not be started. Check if the materials used for tubing, insulation as well as the pumps and valves are suitable for existing temperatures in the system. 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 4 A P P L I AN C E I N S T AL L AT I O N The controller must be installed only in dry, no explosion-dangered places. Installation on the combustible ground is not permissible. 4.1 Opening of the appliance You do not need any tools to open the appliance. Upper part of the appliance housing is bolted by means of two raster with a lower part. In can be unlocked and opened upwards through light pulling at the side parts (straps) of the upper part of the appliance housing (see picture). Keep opening the housing upper part so far upwards until it is latched. Now you can freely install and wire the controller. Before starting shut the cover, please, until it is latched! 4.2 Wall installation In the case of the wall installation proceed in the following way: • Drill installation holes accordingly to the enclosed drilling jig • Screw in two upper screws up to 6 mm distance • Open the appliance as it is described and hang it onto two screws. Now two lower screws can be mounted. • 126mm 84mm Tighten all screws as firmly only as it is really necessary in order to avoid damages in the housing lower part! 118mm Service manual for SOLAREG II VISION 7 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 5 E L E C T R I C AL CONNECTION - OVERVIEW Please, absolutely follow safety instructions in chapter 2 The appliance may be opened only when mains voltage has been safely cut off and it is protected against restarting The connection of all electrical wires takes place on the compo entry in the housing lower part. On the right compo entry side there are (low voltage) connections for sen- sors and flow transmitters. On the left side there are 230V-connections. The following picture shows the connection field of SOLAREG II VISION. FUSE PE - PE A3 A2 A1 L1 S1 S2 S3 S4 S5 S6 S7 MMMMM MM PE - PE N N N N PE Earthed wire S7 Flow transmitter L Phase of mains S1 Temp.- sensor collector 1 N Zero wire of mains S2 Temp.- sensor storage tank 1 A1 Phase switch output 1 S3 Temp.- sensor collector 2 / storage tank 2 N Zero wire switch output 1 S4 Temp.- sensor collector- return A2 Phase switch output 2 S5 Temp.- sensor thermostat or for 2nd temperature differential controller N Zero wire switch output 2 S6 Temp.- sensor antifreeze or for 2nd temperature differential controller A3 Phase switch output 3 N Zero wire switch output 3 Service manual for SOLAREG II VISION 8 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual General connection rules: In the case of all connecting wires skin a cable covering ca. 6 - 8 cm long and the ends of veins ca. 10 mm long. In the case of flexible wires you must have outside or inside the appliance a pull-relief. The vein ends must be equipped with wire end ferrules. In the bushing nipples on the 230V-side you can mount PG9 screwed connections if necessary. Cables are inserted in the appliance through provided holes... All earthed wires must be fixed in binders marked with „PE“ (potential earth). 5.1 230V-connections For 230V-connections you must follow the following points: i In the case of solid electric mains the mains voltage for the controller outside the controller must be able to be switched off by a switch. In the case of electric mains with the help of cables and shock-proof plug this switch may be left out. Controllers are intended for the operation in 230V /50Hz mains. The pumps to be connected and valves must be laid for this voltage! i All switch outputs (A1/A2/A3) are 230V~ closers. If potential-free contacts are needed, appropriate accessories are available i Output A1 is operated, according to an adjustment, as a closer (rotational speed = 100%) or in the case of the function „Rotational speed regulation“(rotational speed < 100%) with block-modulated output signal for the pump P1. i Output A2 behaves as A1 for pump P2 in system types Type 2 and Type 4. In system types Type 1 and Type 3 a valve V1 switched over. i Output A3 is planned for cooling, thermostat or for 2nd temperature differential controller function. All earthed wires must be connected to binders marked with PE. Zero wire binders (N) are electrically connected and are not switched! Service manual for SOLAREG II VISION 9 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 5.1.1 Overview: 230V-connections for SOLAREG II In the following table an assignment of switch outputs for various controller types is presented. Grey fields are absolutely nec- essary for basic function of the system. White fields are intended for optional additional functions. System type Type Description A1 0 1 collector – 1 storage tank P1 1 1 collector – 2 storage tank (pump valve) P1 2 1 collector – 2 storage tank (pump pump) P1 3 2 collector – 1 storage tank (pump valve) P1 4 2 collector – 1 storage tank (pump pump) P1 Switch outputs A2 A3 cooling or thermostat nd or 2 diff. regulation cooling or thermostat V1 or 2nd diff. regulation cooling or thermostat P2 or 2nd diff. regulation cooling or thermostat V1 or 2nd diff. regulation cooling or thermostat P2 or 2nd diff. regulation 5.2 Connection temperature sensor The appliances SOLAREG II work with precise platinum-temperature sensors type PT1000. According to the controller type and function range you need from 2 to 4 sensors. Installation / cabling of temperature sensors: Mount the sensors in the provided places in the collector and storage tank. Pay attention to a good temperature crossing and use, if necessary, heat conducting paste. The wires of the temperature sensor can be lengthened. Up to 15 m long you need a 2 x 0,5mm² cross-section, up to 50 m 2 x 0,75 mm². In the case of long connec- Service manual for SOLAREG II VISION 10 tions (collector) shielded extension lead must be used. On the sensor side do not pinch the shield but cut off and isolate it! Temperature sensors are connected according to the layout plan. Polarity of both veins may be ignored in the case of temperature sensors. Sensor wires must be laid separately from 230V-wires. 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 5.2.1 Overview: sensor connections for SOLAREG II used for antifreeze or 2nd temperature differential controller, it may be used as a universal temperature sensor input. In this case no sensor monitoring takes place. In the following table the assignment of sensor inputs is presented. Grey fields are absolutely necessary for basic function of the system. White fields are intended for optional additional functions. If T6 is not System type Inscription on controller Type Description 0 1 2 3 4 1 collector - 1 storage tank (pump) 1 collector - 2 storage tank (pump valve) 1 collector - 2 storage tank (pump pump) 2 collector - 1 storage tank (pump valve) 2 collector - 1 storage tank (pump pump) 1 2 3 4 Tcoll1 Tst1 - Tret Tcoll1 Tst1 Tst2 Tret Tcoll1 Tst1 Tst2 Tret Tcoll1 Tst1 Tcoll2 Tret Tcoll1 Tst1 Tcoll2 Tret 5 Tth TDiff1 Tth TDiff1 Tth TDiff1 Tth TDiff1 Tth TDiff1 6 Tfr TDiff2 Tfr TDiff2 Tfr TDiff2 Tfr TDiff2 Tfr TDiff2 Before starting shut the cover until it is latched! 5.2.2 Over voltage protector module SOLAREG II is equipped with an over voltage fine protector on all sensor inputs. Additional protection measures are not necessary as a rule for internal sensors. For collector sensor an additional protection (PROZEDA sensor connecting box with over voltage protection) is recommended. External protection elements must not contain any additional capacitors because they may distort measurement result. Service manual for SOLAREG II VISION 11 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 6 O P E R AT I O N / D I S P L AY 6.1 Overview of display and operating elements Number 1 2 3 4 5 Description Display with graphic symbols Control button scroll upwards / + Control button exit / break-off Control button scroll downwards / Control button choice / confirmation Service manual for SOLAREG II VISION 12 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 6.2 Display – maximal display In the following graphics there are all symbols which may appear during work on display, simultaneously presented. During a real work, according to menu position, only some of these symbols appear. Main menu Display values Measuring points assignment Status indication 6.3 Explanation of graphic symbols In the following table the meaning of each symbol is described. Graphic symbole Description Main menu Indication in operation Menu „Info“ Menu „Programming“ Symbol flashes, if possible to be chosen Menu „Manual operation“ Menu „Basic adjustment“ During selection the active symbol flashes. If the menu is chosen by means of the ton, a corresponding symbol is statically presented. All others fade out. Service manual for SOLAREG II VISION 13 but- 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual Graphic symbole dT Description Indication value Temperature difference Indication in operation min Min value appears when minimal values are indicated max Max value appears when maximal values are indicated 5 x 7 segment display Presentation of figures 00000 to 99999 Issue of all figure values, display flashes when a value is changed Temperature in Celsius Temperature difference in Kelvin h Operating hours Productivity indication in kWh Measuring points assignment Temperature measuring point collector1 Temperature measuring point collector2 Temperature measuring point storage tank 1 below (storage tank charging) Temperature measuring point storage tank below (storage tank charging) Temperature measuring point collector-return Temperature measuring point storage tank above (thermostat function) Antifreeze sensor or universal temperature measuring point (T6) (no sensor monitoring) 2nd temperature differential controller Operating hours, energy productivity measurement Service manual for SOLAREG II VISION 14 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual Status indication Solar circulation pump symbol goes round when solar circulation pump is on Switch output 1 is active appears when switch output 1 active (on) Switch output 2 is active appears when switch output 2 active (on) Switch output 3 is active appears when switch output 3 active (on) Reference to system fault display flashes when a fault occurs in the system Safety query for value changes which are stored Input value can be 3 ! ok? rejected or accepted 6.4 Button function Operation of the controller SOLAREG II takes place comfortably and simply by means of 4 operating buttons. By means of operating buttons you can: Graphic symbols of the display lead you in a simple way through the operating structure and show clearly the current menu points, display values or parameters. • recall display values • carry out appliance adjustment Operating buttons have the following functions: Button Function „Up“ „+“ „Call“ „Down“ „-“ „Scroll left“ „Exit“ „Break-off“ „Scroll right“ „Choice“ „Confirmation“ Service manual for SOLAREG II VISION Description • Menu points upwards • Value change: increase of the indicated value by 1 at longer pressing the values raise constantly • Call up of main menu, menu points downwards • Value change: decrease of the indicated value by 1 at longer pressing the values decrease constantly • In main menu scroll to the left • Exit menu • Exit menu point • Break-off value change without storing • In main menu scroll to the right • Choosing one menu point • Confirmation of value change with storing 15 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 6.5 Exemplary appliance operation When you have read the descriptions of the menu in chapter „Operating menu“, you can practise operating steps. Below an operation example is presented. The current col- White: Grey: Button lector temperature is the starting position in menu „Info“. Target: change of the parameter „Storage tank dToff“ from 3K to 4K in menu „Programming“ Symbol static Symbol flashes Graphic indication after Function operation step Description „Exit“ Exit menu’s „Info“ „Scroll right“ Choosing menu „Programming“ „Call“ max 65°C „Down“ dT min 3K Call up menu „Programming“, the first menu point appears Repeated pressing up to menu point „S1 dTmin„ appears. „Choice“ dT min 3K Choosing presented parameter „Up“ dT min 4K Increase of the parameter value from 3K to 4K „Confirm“ „Confirm“ dT min 4K ok? dT min 4K Confirmation of the parameter Storing of the parameter „Exit“ Exit menu „Programming“ „Scroll left“ Choosing menu „Info“ „Call“ Service manual for SOLAREG II VISION Call up menu „Info“ 60°C 16 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 7 O P E R AT I N G To make the operation of the appliance clear, the appliance, operating and display functions are divided into 4 groups (= main menus). Four menus • Info • Programming Menu Info Programming MENU • Manual operation • Basic adjustment give you the information about your solar system. Each active menu is presented in the upper line of the display through corresponding graphic symbol. Overview of contained functions Main menu for automatic regulation of solar system. • Indication of current measuring values • Indication of system condition • Indication of error messages • Indication of operating hours and energy productivity (if available) Change and adjustment of programmable desired values (parameters) Hint: changes can affect system functions Manual operation Switching on and off connected pumps / valves by hand Basic adjustment Information about basic adjustment for system function. Please, pay attention: adjustments and changes must be carried out only by a specialist! Service manual for SOLAREG II VISION 17 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 7.1 Overview: Construction of menu structure The overview shows the whole menu structure. According to basic adjustment and system type some menu points may be left out or shown alternatively („/“). Info Programming Manual operation Basic adjustment I Current temperature Collector / Collector1 Minimal temperature Collector / Collector1 Maximal temperature Collector / Collector1 I Maximal temperature storage tank1 storage tank1 dTmax (dTon) storage tank1 dTmin (dToff) I pump1 on / off I Collector protect. function on / off Collector protection temperature Recooling function Current temperature Maximal temperature Storage tank1 below / Collector2 storage tank2 Minimal temperature storage tank2 Storage tank1 below / Collector2 dTmax (dTon) Maximal temperature storage tank2 Storage tank1 below / Collector2 dTmin (dToff) Current temperature Minimal Storage tank2 below / Stor. tank pump rotational speed in % Minimal temperature Thermostat function Storage tank2 below / Stor. tank Ton Maximal temperature Thermostat function Storage tank2 below / Stor. tank dT nd Current 2 temp.-diff. controller Collector-return-temperature Maximal temperature of heat consumer Tmax nd Current storage temperature 2 temp.-differential con(Storage tank above) troller / Switching hysterisis nd 2 temp. differential controller dTmax Temperature heat generator Antifreeze sensor / nd 2 temp. differential controller Temperature heat generator / Universal measuring point T6 Operating hours pump1 Energy productivity storage tank Operating hours pump2 Energy productivity storage tank Service manual for SOLAREG II VISION 18 pump1 / valve1 on / off heating / cooling / nd 2 diffcontr on /off Recooling temperature Tube collector function Energy productivity measure on/off Choosing used glycol types Mixture ratio Glycol / water in % Litres pro impulse of flow meter Switching on or off function antifreeze Antifreeze function temperature Choice: cooling function, thermostat function, nd 2 temperature differential controller System type 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 7.2 Menu „Info“ In this operational mode all measuring values and operating states are shown. i Only controller-specific values, as well as those needed for activated additional functions are shown! If the values are marked as „reset able“, they may be reseted in the following way: Choice of the value by means of buttons and Resetting of the value by means of the button Message „OK?“ confirm with = no or Indication = yes Reset possible Meaning e.g. Indication of current collector temperature (1/2) no Indication of minimal collector temperature (1/2) Reset able to current temperature yes Indication of maximal collector temperature (1/2) Reset able to current temperature yes Indication of current temperature storage tank (1/2) no Indication of minimal temperature storage tank (1/2) Reset able to current temperature yes Indication of maximal temperature storage tank (1/2) Reset able to current temperature yes Antifreeze sensor Indication of universal temperature measuring points (T6) no Indication of current temperature storage tank thermostat no 60 °C Indication of current temperature collector return no 60 °C 2nd temperature differential controller Temperature of heat generator no 35 °C 2nd temperature differential controller Temperature of heat consumer no 1234 h Operating hours for charging storage tank Reset able to 0 h yes Energy productivity for storage tank Reset able to 0 kWh yes 75 °C min 12 °C max 105 °C 52 °C min 40 °C max 67 °C 25 °C 55 °C 927 kWh Service manual for SOLAREG II VISION 19 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 7.3 Menu „Programming“ All changeable parameters can be checked in this menu and, if necessary, changed. In the factory-set-up usual values, which as a rule guarantee problem-free function of the system, are placed. Indication e.g. The number of indicated values depends on the controller type and the adjusted additional functions. Only the needed values are shown at a time: Value range Typical adjustment 15..95°C 65°C Storage tank: switch-on difference (dTon) 3..40K 7K Storage tank: switch-off difference (dToff) 2..35K 3K Adjustment of minimal pump power at rotational speed regulation 100% = rotational speed regulation off 30%..100 % 100% Switch-on temperature of thermostat function 20..90°C 40°C 1..30K 10K 15..95°C 65°C 3..40K 7K Meaning Storage tank: Permissible maximal temperature max 65 °C dT max 7K dT min 3K min 100 2 40 °C dT Hysteresis of thermostat function 10 K Max 65 °C dT max 7K nd 2 temperature difference controller: maximal temperature of heat consumer Tmax 2nd temperature difference controller: Hysteresis dTmax 7.4 Menu „Manual operation“ For service and test purposes the solar system can be operated by hand. For this purpose 230V switch outputs may be disconnected or connected. During manual operation there is no automatic regulation of the system. To avoid inadmissible operating states this mode of operation changes into „Indication“ after ca. 8 hours and the automatic regulation is activated again. Value range Meaning Indication Switching on / off switch output A1 (solar circulation pump) by hand Service manual for SOLAREG II VISION 20 0 = off 1 = on 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual Switching on / off switch output A2 (pump2 / valve1) by hand 3 Switching on / off switch output A3 (cooling, thermostat or 2 perature difference controller function) by hand nd 0 = off 1 = on tem- 0 = off 1 = on 7.5 Menu „Basic adjustment“ Adjustments and changes in this menu must be carried out only by an installator or competent staff. False adjustments may affect the function of controller and solar system. To avoid accidental changes in menu „Basic adjustment“, it is not editable in normal functioning but has only display function. To be able to carry out any changes, you must choose this menu within the first minute after switching on the appliance. Indication Then the possibility of time-unlimited editing is given. The basic adjustment menu „is blocked“ automatically within one minute after leaving or one minute after switching on the appliance. Meaning Value range 0 = off 1 = on 110..150°C Line / value 4 -- 0 5 -- 0 6 -7 -- 0 100 Switching on or off function collector protection Temperature at which the collector protection function is active Switching on or off function recooling (only when the collector protection is on) Temperature to which the storage tank is recooled after active collector protection function Special function for time-controlled circulation in operation with tube collectors Switching on or off function energy productivity measurement Choosing used glycol types Mixture ratio of coolants 8 -- 10,0 Litres pro impulse of flowmeter 9 -- 0 Switching on or off function antifreezing 10 -- -1 °C 11 -- 0 Temperature at which antifreezing function is active Alternative choice of cooling function, thermostat function or the 2nd temperature difference controller 12 -- 0 System type 0 -- 0 1 -- 120 °C 2 -3 -- 0 40 °C Service manual for SOLAREG II VISION 21 Factory set-up 0 = off 120°C 0 = off 1 = on 30..90°C 0 = off 0 = off 1 = on 0 = off 1 = on 0...9 0 ... 100% 5% - steps 0,5 … 25 l/I 0,5l - steps 0 = off 1 = on -20 °C ... +7 °C 0 = off 0 = off 1 = cooling function 2 = thermostat function 3 = 2nd temperature difference controller 0...4 0 40°C 0 = off 0 50 10,0 0 0 0 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual Glycol types corresponding to menu point 6: 0 1 2 3 4 Anro Ilexan E, Glythermin Antifrogen L Antifrogen N Ilexan E 8 5 6 7 8 9 Ilexan P Tyfocor L5.5 Dowcal 10 Dowcal 20 Dowcal N CONTROLLER The controllers SOLAREG II contain many functions to regulate and monitor solar system. Basically you can distinguish FUNCTIONS • functions for system protection and system monitoring • additional functions. • controller functions for charging a storage tank 8.1 General controller functions The controller collects the temperatures of various measuring points and determines the right time to charge the storage tank on account of programmed (additional) functions and controller parameters. 8.1.1 Storage tank charge Corresponding values in menu „Basic adjustment“: „Programming“ --Maximal temperature --dT max (dTon) Switch-on temperature difference --dT min (dToff) Switch-off temperature difference The storage tank is being charged through the pump on output A1 (A2) up to adjusted maximal temperature so long as the collector temperature becomes higher by a cer. Service manual for SOLAREG II VISION 22 tain amount than the storage tank temperature. Switching action can be adjusted through dTmax (dTon) and dTmin (dToff), but dTon cannot get lower than dToff + 1K 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual Storage tank charge T[°C] max 65 °C dTmin Tst dTmax A1 On Off pump on (A1) 8.1.2 Rotational speed regulation Corresponding values in menu „Basic adjustment“: „Programming“ --Rotational speed min <100% The solar circulation pumps on 230Voutputs A1 and A2 can be operated either in switch-mode (two-point controller) or in a rotational speed regulated way. If the rotational speed regulation is activated the pump power is adjusted by a controller so that switch-on temperature differ- ence „Storage tank dTmax“ is kept constant as much as possible. At lower deviation of „Storage tank dTmax“the pump is operated with the lowest power till the switch-off wave is reached. 8.1.3 Cooling function Corresponding values in menu „Basic adjustment“: „Programming“ 11 -1 --To increase the energy productivity of solar system it may be useful to „by-pass“the solar energy at reaching a certain storage tank temperature or to take it from the storage tank. If the temperature of the storage tank (Tst) goes over the temperature barrier Tstmax – 5K (adjusted maximal storage tank temperature – 5K), the switch output A3 is switched on. Switching off takes place at lower deviation of this temperature. 23 1316BED002_11B-E,Release 11/2008 Service manual for SOLAREG II VISION SOLAREG II VISION Installation and service manual 8.1.4 Thermostat function (reheating) Corresponding values in menu „Basic adjustment“: „Programming“ 11 -2 Thermostat Ton (Tth) --- Thermostat dT The thermostat function is a control circuit dependant of storage charge. In this way e.g. the reheating of the upper stand-by part of the storage tank independent of solar circulation function is enabled. T[°C] Switch output A3 is • switched on when the adjusted temperature „Thermostat Ton“ (Tth) remains under • switched off when the adjusted temperature „Tth + dT“remains over. Thermostat (Storage tank above) dT 10 K Tth 40 °C t on A2 off 8.1.5 2nd temperature differential regulation Corresponding values in menu „Basic adjustment“: „Programming“ 11 -3 Tmax (R2 max) dTmax (R2 dT max) nd The 2 temperature difference regulation enables you, independently of all other control functions, to control an output according to an adjustable temperature difference criterion. TDiff1 is the temperature of a heat generator and TDiff2 of a heat consumer. The output is switched on when TDiff1 >= TDiff2 + Diff.dTmax and simultaneously TDiff2 < Diff.Tmax. It is switched off when TDiff1 < TDiff2 + Diff.dTmax/2 or TDiff2 > Diff.Tmax. For this controller function you need temperature sensor inputs for antifreezing and thermostat function or the 3rd switch output A3. For this reason the controller functions can be only alternatively chosen. Service manual for SOLAREG II VISION 24 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 8.1.6 Tube collector function Corresponding values in menu „Basic adjustment“: „Programming“ 4 -1 --The function „Tube collector“is switched on or off in menu Basic adjustments. If the function is activated a circulation of heat carrying medium through the collector takes place for 30 seconds every 30 minutes. It is necessary to be able to measure a temperature change in the collector when no regulation-conditioned circulation has taken place for a longer time. Indication Meaning Short circuit on temperature sensor of the current measuring point Break on temperature sensor of the current measuring point, Circulation error at activated energy productivity measurement 8.2 System monitoring In the case of an error the flashing symbol ! is shown as a rule. 8.2.1 Sensor monitoring The sensors necessary for control functions and their connecting cables are monitored regarding break and short circuit. If a faulty sensor is recognised by Software, the symbol shown. By scrolling up and down you can find an error source. ! is Usage of false temperature sensors can lead to error message, too. 8.2.2 Flow monitoring Indication Meaning + ! Missing circulation in solar circuit If the option energy productivity measurement is disactivated, the temperature difference between collector and storage tank is Service manual for SOLAREG II VISION 25 checked. If it exceeds the amount of (60K + dTmax), 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual it is then interpreted as an error because in the case of normal system dimensioning and a pump switched on such big differences cannot take place. If the option energy productivity measurement is activated, the flow amount at the pump switched on is checked. If for 15 minutes no flow is recognised it is evaluated as an error. Error message is automatically reseted after eliminating the failure. 8.2.3 Collector protection function / recooling Corresponding values in menu „Basic adjustment“: „Programming“ 0 -1 --1 -- 120 °C 2 -1 3 -- 40 °C (see 7.5) The function is in menu basic adjustments switched on or off. Glycol mixtures can decompose in certain conditions at high temperatures. Therefore the maximal temperature should be limited if possible in the collector circuit. If all storage tanks are charged up to Tmax., the solar circulation pump is cut off. If the collector temperature exceeds the adjusted value „T Kollektor max.“, the solar circulation pump is being switched on until the collector temperature is reduced by 10K. A part of energy is given away through pipelines as a waste, the rest is charged in the storage tank which leads to the increase of . the storage tank temperature over the adjusted maximal temperature. For safety reasons the function is finished when the storage tank has achieved 95°C. If the collector temperature falls by 2K under Tst, the recooling function becomes active. The excess storage tank energy is given away again through the collector so that at the next charging cycle new reserves are available again. The recooling is finished when Tst falls under the adjusted value Tst max. The recooling function can be switched on only when the collector protection function is on. 8.2.4 System protection function The system protection function switches off the system at the temperature exceed „T collector max.“ (see 8.2.3) + 10 K. This function comes into effect no matter if the Service manual for SOLAREG II VISION 26 collector protection is activated or not. As soon as the temperature falls below this value the system is started again. 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 8.3 Additional functions 8.3.1 Energy productivity measurement Corresponding values in menu „Programming“ --- „Basic adjustment“: 5 -1 For energy productivity measurement you need additionally a flow meter and a PT1000-sensor to measure the collector return temperature Tret. Energy productivity of the solar system is calculated on the basis of the temperature „Info“ xxxx kWh difference between collector and collector return temperature and the measured flow quantity. The function is switched on or off in menu „Basic adjustments“. 8.3.2 Operating hours meter Corresponding values in menu „Programming“ --- „Info“ xxxx h So long as the storage tank is charged by a pump, the operating hours meter runs along for each separate pump. The number of operating hours can be read in menu „Info“and for each pump separately reseted to 0. 27 1316BED002_11B-E,Release 11/2008 Service manual for SOLAREG II VISION SOLAREG II VISION Installation and service manual 9 F AI L U R E R E P AI R In the case of system failures you must basically distinguish two categories: • failures which can be recognised by the controller itself and therefore can be indicated • failures which cannot be indicated by the controller 9.1 Failures with error message Error representation on display ! possible reasons Measures • sensor wire broken • sensor defect check wire check sensor resistance, if necessary exchange sensor flashing • short circuit in sensor wire • sensor defect check wire • error in pump connection • pump defect • air in the system • flow meter defect check cabling ! flashing Circulation error: no flow + ! flashing Additionally at energy productivity measurement: Service manual for SOLAREG II VISION • connection with flow meter defect • sensor wire broken • sensor defect 28 check sensor resistance, if necessary exchange sensor exchange pump deaerate the system check if an impeller of the meter moves when the system runs (if visible) check wire check wire check sensor resistance, if necessary exchange sensor 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 9.2 Failures without error message You can check failures and malfunctioning, which are not indicated, and find their error sources according to the following table. If failure repair is not possible on the basis of the description you must ask the deliverers or installer. Error presentation No display function Possible reasons Measures • 230V-mains voltage not switch on or connect the collector check house safety fuse for the existing connection check safety fuse, replace it by a • appliance-internal new one, type 2A/T, if necessary. safety fuse defect check 230V components on short circuit consult with the deliverers • appliance defect Controller does not work • controller is in manual exit menu „Manual operation“. operation • switch-on condition not wait until the switch-on condition is fulfilled fulfilled. Symbol „Pump“ rotates, check cable to pump • pump connection brobut pump does not work ken. make the pump run well • pump is fixed. consult with the deliverers. • no voltage on switch output. Temperature display var- • sensor wires laid near lay sensor wires differently ies strong in short time shield sensor wires 230V-wires intervals • long sensor wires shield sensor wires lengthened without shielding • appliance defect consult with the deliverers Service manual for SOLAREG II VISION 29 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 10 T E C H N I C AL D AT A SOLAREG II Housing Material 100% recyclable ABS-housing for wall installation Measures L x W x D in mm, 175 x 134 x 56; ca. 360 g weight System of protection IP20 according to VDE 0470 Electrical values Operating voltage AC 230 Volt, 50 Hz, -10...+15% Interference grade N according to VDE 0875 Max. conductor cross-section 230V-connections 2,5 mm² fine-strand/single-wire Temperature sensor / temperature range PTF6 - 25°C - 200°C PT1000, 1,000 kΩ at 0°C Testing voltage Switching voltage Capability per one switch output Total capability of all outputs 4 kV 1 min according to VDE 0631 230V∼ / 1A / ca. 230VA for cos ϕ = 0,7-1,0 2A / ca. 460VA maximal Fuse protection fine-wire fuse 5 x 20mm, 2A/T (2 amperes, slow) Others Recommended flow transmitter PVM 1,5/90 1500l/h, Tmax >=90°C, 10l/impuls Operating temperature 0 ... + 50°C Storing temperature -10 ... + 65°C Changes for technical purposes reserved! 11 R E S I S T AN C E T AB L E PT1000 The correct function of temperature sensors can be checked on the basis of the following temperature resistance table with a resistance measuring instrument: Temperature in °C -30 -20 -10 0 10 20 30 40 50 Service manual for SOLAREG II VISION Resistance in Ohm 882 921 960 1000 1039 1077 1116 1155 1194 Temperature in °C 60 70 80 90 100 120 140 200 30 Resistance in Ohm 1232 1271 1309 1347 1385 1461 1535 1758 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 12 T AB L E T Y P I C AL - C U R R E N T AD J U S T M E N T S Adjustments in menu „Programming“ Storage tank1: permissible maximal temperature Storage tank1: switch-on difference (dTon) Storage tank1: switch-off difference (dToff) Storage tank2: permissible maximal temperature Storage tank2: switch-on difference (dTon) Storage tank2: switch-off difference (dToff) Minimal pump power at rotational speed regulation Switch-on temperature of thermostat function Hysteresis of thermostat function 2nd temperature differential controller maximal temperature Tmax 2nd temperature differential controller hysteresis dTmax Adjustments in menu „Basic adjustment“ Switching on or off the function collector protection Temperature at which the collector protection function is active Switching on or off the function recooling (only when the collector protection is on) Temperature to which the storage tank is recooled after the active collector protection function Special function for time-controlled circulation in operation with tube collectors Switching on or off the function energy productivity measurement Alternative choice of the cooling function or the thermostat function Choice of glycol types used Typical adjustment 65 °C 7K 3K 90 °C 7K 3K 100 % 40 °C 10 K 65 °C 7K Typical adjustment Current adjustment 0 = off 120 °C 0 = off 40 °C 0 = off 0 = off 0 = off 0 = Anro Mixture ration of coolants 50 % Litres pro impulse of the flowmeter 10,0 L/I Switching on or off the function antifreezing 0 = off Temperature at which the antifreezing is active -1 °C Alternative choice of the cooling, thermostat function or the 2nd temperature differential controller System type Service manual for SOLAREG II VISION Current adjustment 0 = none type 0 31 1316BED002_11B-E,Release 11/2008 SOLAREG II VISION Installation and service manual 13 T E R M S O F G U AR AN T E E The controlling appliances SOLAREG II are carefully produced and checked at an automatic test place. Should any failures occur, check first if there are any operation / adjustment or system error. Furthermore the pump and temperature sensor connections are to be checked. PROZEDA GmbH provides a guarantee according to the following terms for 24 months beginning from the purchase date. a) The guarantee takes place in the case of existing material defect of the purchased good. If this defect is due to an operating error, exceeding the permissible technical data, false wiring, not permissible technical changes in the appliance made by the customer or other company than ROZEDA GmbH, no guarantee is provided. b) The guarantee requires a notification in writing which describes the defect in detail and a copy of a customer´s invoice. The guarantee takes place according to the free choice of PROZEDA GmbH through - repair (improvement) or – delivery of functioning spare part The maximum repair period is 1 month with effect from receipt of the appliance by PROZEDA GmbH. If two repair attempts go wrong, the customer has the right to the claim to the delivery of functioning spare part. In the case of delivery of a spare part a new guarantee meeting these terms comes into effect. c) Any further warranty (exchange, price reduction) is excluded. Guarantee claims are entitled only to the customer and are not transferable. In the case of defects within the guarantee time communicate first with the deliverers / installators. In the case of returns you always have to enclose error description, if possible the appliance plan and wiring plan. 14 D E C L AR AT I O N OF CONFORMITY The described appliance has been made and tested in compliance with CE-guidelines. Service manual for SOLAREG II VISION 32 1316BED002_11B-E,Release 11/2008
advertisement
Key Features
- Intuitive, menu-conducted operation
- Temperature differential regulation
- Rotational speed control
- Integrated energy productivity measurement
- Storing of all adjusted values
- Various protective functions
Frequently Answers and Questions
How does the SOLAREG II VISION control the solar thermal system?
The SOLAREG II VISION collects temperature data from multiple measuring points in the system and then uses programmed functions and controller parameters to determine the optimal time to charge the storage tank.
What types of systems can the SOLAREG II VISION be used with?
This device is compatible with up to 2 collectors or 2 storage tanks and can be used for five different system types. Refer to the manual for the specific system types.
What are some of the protective functions of the SOLAREG II VISION?
The SOLAREG II VISION includes protective functions such as system protection, collector protection, recooling, and antifreeze to safeguard the system from potential issues.