Below you will find brief information for handheld computer 7530. The 7530 is a handheld computer with a wireless LAN radio that can be used to connect to a network. It is equipped with a touchscreen, a stylus, and a keyboard. It also has a battery that can last for up to 4 or 6 months. You can use this device to access the internet, upload data, and manage files.
Advertisement
Advertisement
Chapter 3: Getting To Know Your 753
0
Storing Batteries
3.9.1 Storing Batteries
Long term battery storage is not recommended. If storage is necessary:
• Always try to use a ‘first-in first-out’ approach to minimize storage time.
• Lithium-Ion batteries age much faster at elevated temperatures. Store batteries at temperatures between 0˚ C and 20˚C.
• Always charge batteries to 40 to 60% before storing them. Batteries can be damaged by an over-discharge phenomenon that occurs when an empty battery is stored for a long period of time such that the cell voltage drops below a lower limit.
• To minimize storage degradation, recharge stored batteries to 40 to 60% every 4 or 6 months to prevent over-discharge damage.
• A ‘never used’ Li-Ion battery that has been stored for 3 years may have limited or no useful life remaining once put into service. Think of batteries as perishable goods.
3.10 Monitoring The Network Connection
If your hand-held is equipped with a wireless LAN radio, it will typically associate with the nearest access point. The radio signal quality meter in the taskbar indicates the relative strength of the communication link.
To access the radio signal icon from the keyboard:
• Press <BLUE> <0> to display the Start Menu .
• Choose System Tray from the menu.
• Use the <LEFT> and <RIGHT> arrow keys to highlight the radio signal icon in the taskbar.
• Press <ENTER> to display the wireless statistics box dialogue box.
If you have a touchscreen:
• Tap on the radio icon in the taskbar to display the wireless statistics dialogue box.
Note: Moving in and out of the radio coverage area can have varying effects on a network session. At times, you may need to renew your connection by logging in again.
Psion Teklogix 753
0
Hand-Held Computer User Manual 55
Chapter 3: Getting To Know Your 753
0
Uploading Data In A Docking Station
3.11 Uploading Data In A Docking Station
The Combo Docking and Quad Docking peripherals allow the 7535 to link to an
Ethernet network. They are typically used to upload transaction data to a server computer when a radio link in not available. When a 7530 is properly inserted in a docking station, a dock icon is displayed in the taskbar at the bottom of the 7530 screen. The 7530 also detects the presence of the Ethernet network. Review the documentation provided with the user application installed in your 7530 before preforming data uploads.
3.12 General Maintenance
3.12.1 Caring For The Touchscreen
The top of the touchscreen is a thin, flexible polyester plastic sheet with a conductive coating on the inside. The polyester can be permanently damaged by harsh chemicals and is susceptible to abrasions and scratches. Using sharp objects on the touchscreen can scratch or cut the plastic, or crack the internal conductive coating.
The chemicals listed below must not come into contact with the touchscreen:
• mustard,
• sodium hydroxide,
• concentrated caustic solutions,
• benzyl alcohol, and
• concentrated miner acids.
If the touchscreen is used in harsh environments, consider applying a disposable screen protector (PN HU6110). These covers reduce the clarity of the display slightly but will dramatically extend the useful life of the touchscreen. When they become scratched and abraded, they are easily removed and replaced.
56 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 753
0
Cleaning The 753
0
3.12.2 Cleaning The 7530
Important: Do not immerse the unit in water. Dampen a soft cloth with mild detergent to wipe the unit clean.
• Use only mild detergent or soapy water to clean the hand-held unit.
• Avoid abrasive cleaners, solvents or strong chemicals for cleaning. The
7535 has a plastic case that is susceptible to harsh chemicals. The plastic is partially soluble in oils, mineral spirits and gasoline. The plastic slowly decomposes in strong alkaline solutions.
• To clean ink marks from the keypad and touchscreen, use isopropyl alcohol.
Psion Teklogix 753
0
Hand-Held Computer User Manual 57
W
ORKING
W
ITH
W
INDOWS
CE
4.1 Navigating In Windows CE And Applications . . . . . . . . . . . . . . . 61
4.1.1 Navigating Using A Touchscreen And Stylus . . . . . . . . . . . . 61
4.1.2 Navigating Using The Keyboard . . . . . . . . . . . . . . . . . . . 62
4.2 Working With Files, Folders And Programs . . . . . . . . . . . . . . . . 63
4.3 The Startup Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
4.3.1 The Desktop Icons . . . . . . . . . . . . . . . . . . . . . . . . . . 65
4.3.2 The Taskbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
4.3.2.1 Using The Taskbar . . . . . . . . . . . . . . . . . . . . . . 66
4.3.2.2 Customizing The Taskbar . . . . . . . . . . . . . . . . . . 67
4.4 The Start Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
4.4.1 The Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
4.4.2 Security Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
4.4.3 The System Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
4.4.4 The Task Manager . . . . . . . . . . . . . . . . . . . . . . . . . . 71
4.4.5 Cycle Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
4.4.6 Power Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
4.4.7 Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
4.4.8 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
4.4.9 Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
4.4.10 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
4.5 Using A Dialogue Box . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Psion Teklogix 753
0
Hand-Held Computer User Manual 59
Chapter 4: Working With Windows CE
Navigating In Windows CE And Applications
4.1 Navigating In Windows CE And Applications
Graphic user interfaces like Windows CE for portable devices and desktop Windows
(2000, XP, etc.) utilize ‘point and click’ navigation. An equivalent keyboard shortcut is also available for every ‘point and click’ action.
Windows CE supports the same ‘point and click’ user interface and keyboard shortcuts as desktop Windows with one difference – the ‘point and click’ action is accomplished using a touchscreen rather than a mouse. Actions can be performed using any combination of keyboard shortcuts or touchscreen tapping (provided your
7530 is equipped with a touchscreen).
4.1.1 Navigating Using A Touchscreen And Stylus
Note: If the touch screen is not registering your screen taps accurately, the touchscreen may need recalibration. Refer to “Calibrating The Touchscreen” on page 41.
A touchscreen is an optional feature. A 7530 equipped with a touchscreen has a
stylus – a pointing tool that looks like a pen – stored in a slot at the top of the 7530.
The stylus is used to select objects on the touchscreen.
Note: To prevent damage to the touchscreen, use only the stylus (pen) supplied with your 753 0 .
To open a file, launch an applet or open a folder:
• Double-tap the stylus on the appropriate icon.
Psion Teklogix 753
0
Hand-Held Computer User Manual 61
Chapter 4: Working With Windows CE
Navigating Using The Keyboard
4.1.2 Navigating Using The Keyboard
If your 7530 has a standard screen (rather than a touchscreen), choosing icons and navigating dialogue boxes, displaying the desktop, and so on requires keyboard input. If your unit has already been fully configured and your application is launched at startup, you’ll have little need for keyboard navigation.
Operation Key or Key Combination
Switch between active applications <ALT> <TAB>
Open task manager <ALT> <ESC>
Move the cursor
Open file, folder or icon
Arrow keys
<ENTER>
Exit & Save
Close/Exit & Do Not Save
<ENTER>
<ESC>
Navigate Dialogue Boxes
<TAB>
To move cursor up <SHIFT> <TAB>
To display the contents of the next ‘tab’ in a dialogue box <CTRL> <TAB>
<SPACE> Select Radio Button/Press Button
Go to Start Menu <BLUE><0>
Table 4.1 Keyboard Navigation
Keep in mind that unlike a desktop computer, the 7530 does not support key chording (pressing two keys at the same time). You must press one key followed by the next in sequence.
Refer to “Working With Files, Folders And Programs” on page 63 for additional details about keyboard navigation.
62 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Working With Files, Folders And Programs
4.2 Working With Files, Folders And Programs
Folder
Program Icon
File
Figure 4.1 Working With Windows Icons
• Use the arrow keys to highlight the icon you want to open or launch.
• Press <ENTER>.
If you have a touchscreen:
• Double-tap on the appropriate icon – either a folder icon, a program icon or a file icon – to open or launch your selection.
Psion Teklogix 753
0
Hand-Held Computer User Manual 63
Chapter 4: Working With Windows CE
The Startup Desktop
4.3 The Startup Desktop
When the 7530 boots up, the startup desktop (shell) is displayed. Any applications stored in the Startup folder start up immediately.
Note: The startup folder is located in \Windows\StartUp and
\Flash Disk\StartUp.
Figure 4.2 The 7530 Startup Desktop
To access desktop icons:
• Use the arrow keys to highlight the icon, and press <ENTER> to launch the highlighted icon.
Note: If the arrow keys do not highlight the desktop icons, the desktop may not be selected. Press <BLUE> 0 (zero) to display the
Start Menu
, and select
Desktop
. Now the desktop will be “in focus” and the arrow keys will highlight the icons.
If you have a touchscreen:
• Tap on the icon to open a window or, in the case of an application icon, launch an application.
64 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
The Desktop Icons
4.3.1 The Desktop Icons
The icons displayed in the startup desktop operate in much the same way as those displayed on any standard PC desktop that is running Windows®.
My Computer
Choosing this icon displays the contents of your 7530 computer. If you’re not sure how to work with the files, folders and programs displayed, refer to “Working With
Files, Folders And Programs” on page 63.
Recycle Bin
This option temporarily contains items that were deleted, allowing you to either permanently delete or restore these items.
Internet Explorer
Choosing this icon launches Internet Explorer – a standard Windows CE version.
Keep in mind that your supervisor will need to set up access using the
Internet Options
and the
Network and Dial-up Connections
icons in the
Control Panel
.
Remote Desktop Connection
This option allows your 7530 to communicate with a remote desktop PC. “Remote
Desktop Connection” on page 83 provides a website with step-by-step instructions.
Psion Teklogix 753
0
Hand-Held Computer User Manual 65
Chapter 4: Working With Windows CE
The Taskbar
4.3.2 The Taskbar
Figure 4.3 The Taskbar
The 7530 is equipped with a taskbar at the bottom of the screen. It displays icons through which you can view the battery capacity and radio signal quality of your unit. If the hand-held is attached to a charger, cradle, docking station or PDM, an associated icon is displayed. In addition, the taskbar displays the application(s) currently running on your unit and the security level assigned to your 7530.
The taskbar also displays active modifier keys – <SHIFT>, <ALT>, <CTRL>,
<BLUE> and <ORANGE>. Keys that have been locked “on” are displayed in
uppercase letters. For example, if you press the <CTRL> key twice to lock it “on”, it is displayed as CTRL KEY in the taskbar.
4.3.2.1
Using The Taskbar
• Press <BLUE> <0> to display the
Start Menu
.
• Type <Y> to choose System Tray from the menu.
• Use the arrow keys to highlight the icon in the taskbar about which you’d like more information.
• Press <ENTER> to display the appropriate dialogue box.
If you have a touchscreen:
• Using the stylus, tap on the indicator you want to view – the battery icon for example – to display a dialogue box listing the current battery capacity information.
66 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Customizing The Taskbar
4.3.2.2
Customizing The Taskbar
To customize the taskbar so that it displays only those icons you require:
• Press <BLUE> <0> (zero) to display the
Start Menu
.
• Highlight the Settings option, highlight
Taskbar...
in the sub-menu, and press <ENTER>.
The
Taskbar and Start Menu
dialogue box is displayed.
Figure 4.4 Taskbar And Start Menu Settings
• Under the
General
tab, highlight the options you want to activate, and press the <SPACE> key to select them. A check mark indicates active items.
If you have a touchscreen:
• Tap the stylus on the items you want to activate or deactivate. The check mark indicates active items.
Psion Teklogix 753
0
Hand-Held Computer User Manual 67
Chapter 4: Working With Windows CE
The Start Menu
4.4 The Start Menu
Note: Some of the Start Menu items may be disabled based on the 753 0 ’s current security settings.
The
Start Menu
lists the operations you can access and work with. It is available from the startup desktop or from within any application.
To display the menu:
• Press <BLUE> <0> (zero).
Figure 4.5 Start Menu
• Use the arrow keys to highlight a menu item, and press <ENTER>, or
If the menu item has an underlined character:
• Type the underlined alpha character – for example, to display the Power
Info dialogue box , type the letter p.
If you have a touchscreen:
• Tap on the Windows®
Start
button in the taskbar. Tap on the item in the menu with which you want to work.
4.4.1 The Desktop
Choosing the Desktop option from the
Start Menu
displays the 7530 desktop.
68 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Security Settings
4.4.2 Security Settings
Choosing the Security option from the
Start Menu
displays a dialogue box in which you can define the access level for the 7530 –
Teklogix
,
Supervisor
or
User
.
Figure 4.6 Security Levels
Security Level
These security levels define the options accessible to the operator in the
Start Menu
and the taskbar. When you change security levels, you’ll need to enter the appropriate password in the
Password
textbox. The security level is represented by an icon in the shape of a lock in the taskbar.
Changing A Password
Note: Keep in mind that this is the same password as that assigned through the
Password
control panel applet. Refer to “Control Panel Icons” on page 84.
To assign a password:
• Choose a security level, and enter the existing password in the
Password
field
• Choose the
Set Password
button.
A dialogue box labelled
Password Properties
is displayed.
• Type the new password in the
Password:
text box
• In the
Confirm Password:
text box, retype the new password.
Psion Teklogix 753
0
Hand-Held Computer User Manual 69
Chapter 4: Working With Windows CE
The System Tray
Configuring Security
Choosing the
Configure
button displays the
Configure Security
dialogue box.
Figure 4.7 Configuring Security
This dialogue box allows you to determine which security levels will have an associated icon displayed in the taskbar. By default, a security icon is not displayed for user-level security.
4.4.3 The System Tray
The System Tray option allows access to the icons in the taskbar at the bottom of the screen. The taskbar displays indicators such as a battery capacity gauge and the security level. These indicators are attached to dialogue boxes that provide additional information.
• Choose System Tray from the
Start Menu
.
When System Tray is chosen, the taskbar icons become accessible. To display the dialogue box attached to an icon:
• Use the arrow keys to highlight an icon – for example – the security icon.
• Press <ENTER> to display the security level dialogue box.
If you have a touchscreen:
• Tap on the icon with which you want to work. The associated dialogue box is displayed.
70 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
The Task Manager
4.4.4 The Task Manager
The Task Manager option allows you to switch to another task or to end an active task. To display the task manager window:
• Press <BLUE><0><T>, or
• Press <ALT> <ESC>.
Figure 4.8 Task Manager
4.4.5 Cycle Tasks
When Cycle Tasks is selected (and the Task Manager is not open), you can cycle through active applications. To choose this option:
• Press <BLUE><0>, and type <C>, or
• Press <ALT> <TAB>.
4.4.6 Power Info
Selecting Power Info from the
Start Menu
displays the
Power Properties
dialogue box.
This dialogue box indicates the remaining charge capacity of the battery.
Psion Teklogix 753
0
Hand-Held Computer User Manual 71
Chapter 4: Working With Windows CE
Programs
4.4.7 Programs
With Programs highlighted, press the <RIGHT> arrow key to display a sub-menu of options.
Figure 4.9 Program Sub-Menu
This sub-menu allows you to choose
ActiveSync
and
Command Prompt
, and you can access the
Internet Explorer,
installed applications (e.g.,
Open Tekterm
),
Remote Desktop Connection
or
Windows Explorer.
ActiveSync
®
This option allows you to connect to another device using ActiveSync.
Command Prompt
Command Prompt
is used to access the DOS command prompt. At the prompt, you can type DOS commands such as dir to display all the directories in the drive.
Internet Explorer
The 7530 is equipped with Microsoft® Internet Explorer consistent with all
Windows CE devices on the market. You can access the
Internet Options
icon through the
Start Menu
under Settings>Control Panel or by double-tapping on the desktop icon labelled
My Computer
and then, double-tapping on the
Control Panel
icon.
72 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Settings
Windows Explorer
Windows Explorer
installed on your 7530 is consistent with all Windows CE.NET 4.2 devices. You can access this option either from the
Start Menu
under
Programs>Windows Explorer .
Remote Desktop Connection
Remote Desktop Connection
is a 7530 application used to connect to a Windows Terminal
Server so that you can run a “session” on the Server machine using the 7530
(Windows CE device). “Remote Desktop Connection” on page 83 provides a website with details about this option.
4.4.8 Settings
With Settings highlighted, pressing the <RIGHT> arrow key displays a sub-menu of options, including
Control Panel, Network and Dial-up Connections
and
Taskbar and
Start Menu
settings.
Figure 4.10 Settings Sub-Menu
Control Panel
The
Control Panel
contains applets used to configure hardware, the operating system and the shell. If your 7530 is running with the Psion Teklogix Tekterm application or another application, additional configuration applets may appear in the
Control Panel.
Psion Teklogix 753
0
Hand-Held Computer User Manual 73
Chapter 4: Working With Windows CE
Run
Network And Dial-Up Connections
The
Network and Dial-up Connections
window allows you to configure the 7530 radio or execute an existing configuration. Refer to “Configuring An IEEE 802.11 Radio
Installed In The 7530” on page 18 for radio setup details.
Taskbar And Start Menu
The
Taskbar and Start Menu
option displays a dialogue box in which you can customize the taskbar, choosing which options will be displayed. Refer to
“Customizing The Taskbar” on page 67 for additional details about this option.
4.4.9 Run
Choosing the Run option from the
Start Menu
displays a dialogue box in which you can enter the name of the program, folder or document you want to open or launch.
Figure 4.11 Run Dialogue Box
74 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Shutdown
4.4.10 Shutdown
With Shutdown highlighted, pressing the <RIGHT> arrow key displays a sub-menu of options, including
Suspend, Warm Reset
and
Cold Reset.
Figure 4.12 Shutdown Sub-Menu
Note: This menu varies slightly depending on the security level chosen. When the 753 0 is set to User level, the
Shutdown
option is replaced by
Suspend
.
A sub-menu is not available.
At Teklogix security level, an additional option is available in the sub-menu –
Bootloader
. This option behaves like cold-reset, except that the 753 0 starts Bootloader rather than Windows CE.
Suspend
The
Suspend
option suspends the 7530 immediately – this is equivalent to turning the hand-held off.
Warm Reset
The
Warm Reset
option resets the 7530, leaving all saved files and (registry) settings intact. Any unsaved data is lost.
Cold Reset
The
Cold Reset
option resets the 7530. Any files not stored in permanent memory are lost. However, the registry settings are saved.
Psion Teklogix 753
0
Hand-Held Computer User Manual 75
Chapter 4: Working With Windows CE
Using A Dialogue Box
4.5 Using A Dialogue Box
A dialogue box (like the samples in Figure 4.13) appears when you need to make selections and enter further information.
You can move between dialogue items by tapping on them, or by pressing the arrow keys and the <TAB> key. (<SHIFT> <TAB> moves the cursor backwards.)
Tabs
Radio
Button
Textbox
Checkbox
Dropdown Menu
Button
Figure 4.13 Dialogue Boxes
Note: If your unit is equipped with a touchscreen, you can use the stylus to tap on an element in a dialogue box to select or deselect it, display dropdown menu items, save your selections, and so on.
Dialogue boxes contain one or more of the following elements:
Tab: A tab separates different elements of a dialogue box. Press the <TAB> key until a tab in the dialogue box is highlighted. To display adjoining tabs, press the
<RIGHT> or <LEFT> arrow key. To display the information in the next tab from anywhere in the window, press <CTRL> <TAB>.
Textbox: A textbox requires that you type information. Press the <TAB> key to highlight the textbox and then type the appropriate information.
Dropdown: This type of menu is identified by up and down arrows next to the dropdown menu to indicate that additional options are available. Press the <TAB> key to highlight the menu, and use the arrow keys on your keyboard to cycle through the options.
76 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Using A Dialogue Box
Checkbox: This box allows you to select or deselect an option. To select or deselect a checkbox, press the <TAB> key to highlight the checkbox, and press the
<SPACE> key to select (
√
) or deselect it.
Radio buttons: These buttons allow you to choose from a number of options. For example, in the sample screen in Figure 4.13 on page 76 you can choose to
‘Obtain an
IP address via DHCP’
or
‘Specify an IP address’
. Press the <TAB> key to highlight a radio button option, and then select a radio button by pressing the arrow keys to highlight the appropriate option.
Buttons: This type of button allows you to ‘Save’, ‘Delete’ and so on the options you’ve chosen in a dialogue box. Use the <TAB> key to highlight the button you want to use. Press the <ENTER> key to activate it.
Saving Your Choices: Once you’ve made all your changes, press the <ENTER> key to save your changes and exit the window.
Note: A dialogue box item that is displayed in grey text indicates that it is not currently available.
Psion Teklogix 753
0
Hand-Held Computer User Manual 77
C
ONFIGURATION
5.1 Remote Desktop Connection . . . . . . . . . . . . . . . . . . . . . . . . 83
5.2 Pocket PC Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . 83
5.3 The Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
5.4 Control Panel Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
5.5 Basic Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
5.5.1 Display Properties . . . . . . . . . . . . . . . . . . . . . . . . . . 88
5.5.1.1 Display Contrast . . . . . . . . . . . . . . . . . . . . . . . 88
5.5.1.2 Display Backlight . . . . . . . . . . . . . . . . . . . . . . 89
5.5.1.3 Display Appearance . . . . . . . . . . . . . . . . . . . . . 91
5.5.2 Keyboard Properties . . . . . . . . . . . . . . . . . . . . . . . . . 92
5.5.2.1 Key Repeat. . . . . . . . . . . . . . . . . . . . . . . . . . 92
5.5.2.2 Keyboard Backlight . . . . . . . . . . . . . . . . . . . . . 93
5.5.2.3 Keyboard One Shot Modes . . . . . . . . . . . . . . . . . 94
5.5.2.4 Keyboard Macro Keys . . . . . . . . . . . . . . . . . . . . 95
5.5.2.5 Unicode Mapping . . . . . . . . . . . . . . . . . . . . . . 97
5.5.3 Volume And Sound Properties . . . . . . . . . . . . . . . . . . . . 99
5.5.3.1 Volume Adjustments . . . . . . . . . . . . . . . . . . . . . 99
5.5.4 Power Management Properties . . . . . . . . . . . . . . . . . . . 100
5.5.4.1 Battery Capacity . . . . . . . . . . . . . . . . . . . . . . 100
5.5.4.2 Power Saving Schemes . . . . . . . . . . . . . . . . . . 101
5.5.4.3 Suspend Threshold. . . . . . . . . . . . . . . . . . . . . 102
5.5.4.4 Charger Details . . . . . . . . . . . . . . . . . . . . . . 103
5.5.5 Stylus Properties . . . . . . . . . . . . . . . . . . . . . . . . . . 103
5.5.5.1 Setting Double-Tap Sensitivity . . . . . . . . . . . . . . 104
5.5.5.2 Touchscreen Calibration . . . . . . . . . . . . . . . . . . 104
5.5.6 Certificate Assignment . . . . . . . . . . . . . . . . . . . . . . . 105
5.7 Scanner Properties Setup . . . . . . . . . . . . . . . . . . . . . . . . . 118
5.7.1 Scanner Options . . . . . . . . . . . . . . . . . . . . . . . . . . 118
5.7.2 Bar Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
5.7.2.1 Code 39 Settings . . . . . . . . . . . . . . . . . . . . . . 122
5.7.2.2 Code 128 Settings . . . . . . . . . . . . . . . . . . . . . 124
Psion Teklogix 753
0
Hand-Held Computer User Manual 79
Chapter 5: Configuration
5.7.2.3 EAN 13 Settings . . . . . . . . . . . . . . . . . . . . . . 125
5.7.2.4 EAN 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
5.7.2.5 UPC And EAN Settings . . . . . . . . . . . . . . . . . . 127
5.7.2.6 UPC A Settings. . . . . . . . . . . . . . . . . . . . . . . 127
5.7.2.7 UPC E Settings . . . . . . . . . . . . . . . . . . . . . . . 127
5.7.2.8 Codabar. . . . . . . . . . . . . . . . . . . . . . . . . . . 128
5.7.2.9 Code 93. . . . . . . . . . . . . . . . . . . . . . . . . . . 128
5.7.2.10 Code 11 . . . . . . . . . . . . . . . . . . . . . . . . . . 128
5.7.2.11 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . 129
5.7.2.12 MSI Plessey . . . . . . . . . . . . . . . . . . . . . . . . 129
5.7.2.13 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . 129
5.7.2.14 IATA 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . 130
5.7.2.15 Postal: Australian . . . . . . . . . . . . . . . . . . . . . 130
5.7.2.16 Postal: Japanese . . . . . . . . . . . . . . . . . . . . . . 130
5.7.2.17 Postal: Korean. . . . . . . . . . . . . . . . . . . . . . . 130
5.7.2.18 Postal: PlaNET . . . . . . . . . . . . . . . . . . . . . . 131
5.7.2.19 Postal: PostNET. . . . . . . . . . . . . . . . . . . . . . 131
5.7.2.20 Postal: Royal Mail . . . . . . . . . . . . . . . . . . . . 131
5.7.2.21 2D DataMatrix . . . . . . . . . . . . . . . . . . . . . . 131
5.7.2.22 2D Maxicode . . . . . . . . . . . . . . . . . . . . . . . 131
5.7.2.23 2D PDF-417. . . . . . . . . . . . . . . . . . . . . . . . 131
5.7.2.24 2D Micro PDF-417 . . . . . . . . . . . . . . . . . . . . 132
5.7.2.25 2D QR Code . . . . . . . . . . . . . . . . . . . . . . . 132
5.7.2.26 2D RSS Code . . . . . . . . . . . . . . . . . . . . . . . 132
5.7.2.27 Aztec . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
5.7.3 Translations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
5.8 SNMP (Simple Network Management Protocol) Setup. . . . . . . . . . 134
5.8.1 Contact Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
5.8.2 Communities Tab . . . . . . . . . . . . . . . . . . . . . . . . . . 136
5.8.2.1 Adding A Community . . . . . . . . . . . . . . . . . . . 137
5.8.2.2 Modifying A Community Setting . . . . . . . . . . . . . 138
5.8.2.3 Removing An Existing Community . . . . . . . . . . . . 138
5.8.3 Trap Destination Tab . . . . . . . . . . . . . . . . . . . . . . . . 139
5.8.3.1 Enabling Authentication TRAPS. . . . . . . . . . . . . . 139
5.8.3.2 Adding A Destination . . . . . . . . . . . . . . . . . . . 139
5.8.3.3 Changing A Destination . . . . . . . . . . . . . . . . . . 140
5.8.3.4 Removing A Trap Destination . . . . . . . . . . . . . . . 140
80 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
5.8.4 Permitted Hosts Tab . . . . . . . . . . . . . . . . . . . . . . . . 141
5.8.4.1 Adding A Host . . . . . . . . . . . . . . . . . . . . . . . 141
5.8.4.2 Changing A Host. . . . . . . . . . . . . . . . . . . . . . 142
Psion Teklogix 753
0
Hand-Held Computer User Manual 81
Chapter 5: Configuration
Remote Desktop Connection
5.1 Remote Desktop Connection
Remote Desktop Connection
is a 7530 application used to connect to a Windows Terminal
Server so that you can run a “session” on the Server machine, using the 7530
(Windows CE device).
Refer to the following website for step-by-step information about setting up this connection: http://www.microsoft.com/WindowsXP/pro/using/howto/gomobile/remotedesktop/default.asp
5.2 Pocket PC Compatibility
The 7530 supports the AYGShell API set that allows PocketPC-compatible applications to run on the hand-held. Microsoft® Windows® CE.NET 4.2 is designed to include application programming interface (API) compatibility support for the Microsoft Windows Powered Pocket PC 2002 shell in 7530s running
Windows® CE.NET 4.2.
The website listed below describes the APIs exposed through AYGShell and the application compatibility between Windows Powered Pocket PC 2002-based applications and Windows CE.NET 4.2-based devices: http://msdn.microsoft.com/library/default.asp?url=/library/en-us/dncenet /html/WINCENET_CEPCC_App.asp
5.3 The Control Panel
The Windows CE
Control Panel
provides a group of icons through which you can set a variety of system-wide properties, such as mouse sensitivity, network configuration and the desktop color scheme.
Note: If you are uncertain how to move around a dialogue box and make selections, review “Using A Dialogue Box” on page 76.
When the 7530 boots up, the startup desktop (shell) is displayed, and any applications stored in the Startup folder start up immediately.
To access the Windows CE
Control Panel
:
• Press BLUE> <0> to display the
Start Menu
.
• Highlight Settings in
Start Menu
, and press the <RIGHT > arrow key to highlight the
Control Panel
option .
• Press the <ENTER> key to display the contents of the
Control Panel
window.
Psion Teklogix 753
0
Hand-Held Computer User Manual 83
Chapter 5: Configuration
Control Panel Icons
If you have a touchscreen:
• Use the stylus to tap on the Windows
Start
button in the taskbar to display the
Start Menu
. Tap on Settings>
Control Panel
.
The
Control Panel
folder contains icons used in the setup of your 7530.
Figure 5.1 Control Panel
5.4 Control Panel Icons
The Windows CE
Control Panel
provides a group of icons that allow you to customize and adjust settings on your 7530.
Date/Time
Allows you to set the current Month, Date, Time and Time Zone on your unit.
Display
Changes the appearance (window colour scheme) on the unit desktop.
Keyboard
Toggles character repeat on and off and specifies delay and rate for repeated characters. It also allows you to adjust the keyboard backlight threshold and intensity.
84 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Control Panel Icons
Volume & Sound
Allows you to adjust the volume of the beep that is emitted to indicate events like warnings, key clicks and, if your unit is equipped with a touchscreen, screen taps.
Sounds (wave files) cannot be reproduced on 7530 units. The beeper volume and the conditions under which it sounds are tailored from within the application installed on your unit.
Mouse Properties
For units equipped with touchscreens, this icon allows you to customize the sensitivity and speed of the stylus double-tap.
Owner
Provides fields in which you can specify owner information. A ‘
Notes
’ tab allows additional information to be entered and displayed when the unit is powered up. ‘
Network ID
’ tab information is used to access network resources.
(This information should be provided by your System Administrator.)
Password
Allows you to assign a password to restrict access to elements of the unit.
Once assigned, password access cannot be circumvented so it is important that you write down your password and keep it in a safe place. Refer to
“Security Settings” on page 69 for details.
Power
Displays battery pack power status. (Alternately, battery status can be accessed through the taskbar.) The
‘Power Scheme’
tab allows you to determine a suspend states, and the
‘Charger’
tab determines whether or not a battery that requires it, can be recalibrated. (Refer to “Power Saving
Schemes” on page 101 for details.)
Psion Teklogix 753
0
Hand-Held Computer User Manual 85
Chapter 5: Configuration
Control Panel Icons
Regional Settings
Allows you to specify the local language the display text will use along with the format of numbers, currency, time and date for your region.
Remove Programs
Lists the programs that can be removed from your unit. To remove a program, select it and then click on the
Remove
button.
S tylus
Adjusts how Windows CE recognizes your double-tap (as slow or rapid successive taps).
Under the ‘
Calibration
’ tab, you can recalibrate your touchscreen by tapping on the ‘Recalibrate’ button and following the directions on the calibration screen.
System
Displays system and memory properties. Under the
Memory
tab, you can allocate memory between storage memory and program memory.
Dialing
Specifies dialing settings, including area code, country code, dial type and the code to disable call waiting. You can store multiple patterns – for example, ‘Work’, ‘Home’, and so on using this dialogue box.
Certificates
A public key is transmitted as part of a certificate. The certificate assigned through this icon is used to ensure that the submitted public key is, in fact, the public key that belongs to the submitter. The client checks that the certificate has been digitally signed by a certification authority that the client explicitly trusts. “Certificate Assignment” on page 105 directs you to the appropriate setup information.
86 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Control Panel Icons
PC Connection
Enables direct connections to a desktop computer. Selecting the ‘
Change Connection
’ button allows you to change the type of direct connect to your PC.
Teklogix Scanners
Used to set up scanner parameters and choose the bar code symbologies that the 7530 scanner will successfully read.
Network And Dial-up Connections
Displays a network window from which the 7530 radio can be configured and an existing configuration can be executed. Refer to “Configuring An
IEEE 802.11 Radio Installed In The 7530” on page 18 for details.
Internet Options
Used to configure your Internet browser including options such as identifying the default and search page that the browser applies when connecting to the Internet, setting the cache size, specifying the Internet connection options, and defining the security level that is applied when browsing.
SNMP
SNMP (Simple Network Management Protocol) is the protocol used to monitor and manage devices attached to a TCP/IP network.
Input Panel
The 7535 is equipped with the framework for a Soft Input Panel (SIP) should you need to design your own SIP.
Psion Teklogix 7535 Hand-Held Computer User Manual 87
Chapter 5: Configuration
Basic Setup
5.5 Basic Setup
5.5.1 Display Properties
• In the
Control Panel
, choose the
Display
icon.
Figure 5.2 Choosing The Display Icon
5.5.1.1
Display Contrast
The
Contrast
tab allows you to adjust the 7530 display contrast to suit the environment in which you are using the hand-held.
88 Psion Teklogix 753
0
Hand-Held Computer User Manual
• In the Display Properties dialogue box, open the Contrast tab.
Chapter 5: Configuration
Display Backlight
Figure 5.3 Display Contrast Properties
Sliding bar in the
Contrast
tab to the left decreases or darkens the display contrast.
Sliding the bar to the right to increases or lightens the display contrast.
5.5.1.2
Display Backlight
The backlight is activated for a configurable amount of time if the ambient light is below a specified threshold and if the 7530 is in use (key press, scanner trigger or data received from the host). The
Display Properties
dialogue box in the
Control Panel
allows you to specify the intensity of the backlight along with how the backlight behaves in low-light conditions and when the unit is not in use.
Note: Keep in mind that this option may be restricted to supervisory use only.
Psion Teklogix 753
0
Hand-Held Computer User Manual 89
Chapter 5: Configuration
Display Backlight
• In the Display Properties dialogue box, open the Backlight tab.
Figure 5.4 Display Backlight Properties
Note: Backlight changes take affect immediately. You do not need to reset the 753 0 .
ON Threshold
The 7530 is equipped with an ambient light sensor. This sliding bar allows you to determine how dark the ambient light needs to be before the backlight turns on.
Intensity
This parameter is used to adjust the light intensity of the 7530 backlight. Sliding the bar to the left lowers the light intensity, and sliding it to the right raises the intensity.
Bright For
The value chosen from this dropdown menu determines the duration of time that the backlight stays on at the configured intensity when a unit is not in use.
Dim For
The value chosen from this dropdown menu determines the duration of time that the backlight stays on at half the configured intensity (dimmed backlight) when a unit is not in use.
90 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Display Appearance
External Power Checkbox
When you select (
√
) the checkbox next to
‘When using external power keep the backlight always ON.
’, the backlight remains ON at the configured intensity when the 753 0 is
operating with external power (not battery power). If the 7530 is drawing power from its battery, this option is ignored and the other parameters defined in
Display
Properties
dialogue box take affect.
5.5.1.3
Display Appearance
• In the Display Properties dialogue box, open the Appearance tab.
Figure 5.5 Display Appearance Properties
This dialogue box allows you to customize the display colour scheme.
Psion Teklogix 753
0
Hand-Held Computer User Manual 91
Chapter 5: Configuration
Keyboard Properties
5.5.2 Keyboard Properties
This icon displays the Keyboard Properties dialogue box in which you can adjust the repeat rate of the keys, the intensity of the keyboard backlight and the behaviour of the <BLUE> and <ORANGE> modifier keys. This dialogue box also allows you to define macro keys and Unicode characters.
• In the
Control Panel
, choose the
Keyboard
icon.
Figure 5.6 Choosing The Keyboard Icon
5.5.2.1
Key Repeat
• In the Keyboard Properties dialogue box, open the Repeat tab.
Figure 5.7 Key Repeat Properties
92 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Keyboard Backlight
Repeat Delay
The value assigned for this parameter determines the delay in milliseconds between repeat characters. Sliding the
Repeat Delay
bar to the left increases the delay between key repeats while sliding the bar to the right shortens the repeat delay time.
Repeat Rate
The value assigned for the
Repeat Rate
parameter determines how quickly the key you press repeats and is measured in characters per second (cps). Sliding the bar to the left slows the repeat rate, and sliding the bar to the right increases the repeat rate.
Note: Use the field at the bottom of this dialogue box to test the repeat delay and rate settings you’ve chosen.
5.5.2.2
Keyboard Backlight
• In the Keyboard Properties dialogue box, open the Backlight tab.
Figure 5.8 Keyboard Backlight Properties
ON Threshold
The
ON Threshold
sliding bar allows you to determine how dark the ambient light needs to be before the keyboard backlight turns on.
Intensity
This parameter is used to adjust the light intensity of the 7530 keyboard backlight.
Sliding the bar to the left darkens the keyboard backlight intensity, and sliding it to the right lightens the intensity.
Psion Teklogix 753
0
Hand-Held Computer User Manual 93
Chapter 5: Configuration
Keyboard One Shot Modes
ON Time
The value chosen from this dropdown menu determines the duration of time that the keyboard backlight stays on when a unit is not in use.
5.5.2.3
Keyboard One Shot Modes
• In the Keyboard Properties dialogue box, open the One Shots tab.
Figure 5.9 Keyboard One Shot Properties
When these options are enabled (
√
), the <ORANGE> and <BLUE> keys only remain active until the next key is pressed. If the ‘One Shots’ options are disabled
(the checkbox is left blank), the <ORANGE> and <BLUE> keys are locked ‘on’ when pressed only once; they remain ‘on’ until they are pressed a second time to unlock them.
Note: Keep in mind that checking the taskbar lets you know whether or not these keys are locked on. When the <ORANGE> and <BLUE> keys are locked ‘on’, the taskbar at the bottom of the screen displays them in uppercase characters –
BLUE KEY
and
ORANGE KEY. If
these keys are displayed in lowercase characters in the taskbar, you’ll know that the
Blue Key
and the
Orange Key
are not locked. They will become inactive following a key press.
94 Psion Teklogix 753
0
Hand-Held Computer User Manual
5.5.2.4
Keyboard Macro Keys
• In the Keyboard Properties dialogue box, open the Macros tab.
Chapter 5: Configuration
Keyboard Macro Keys
Figure 5.10 Macro Dialogue Box
A macro has 20 programmable characters (or “positions”). The macro keys can be programmed to replace frequently used keystrokes, along with the function of executable keys including <ENTER>, <BKSP> and <DEL> (<BLUE>-<BKSP>), function keys and arrow keys.
Recording And Saving A Macro
You can program up to 12 macro keys on a 58-key keyboard and 6 macro keys on a
36-key keyboard.
• In the Macro: menu, highlight a macro key number – for example, macro 1 to assign a macro to macro key <M1> .
Press the <TAB> key twice to highlight the
Record Macro
button, and press <ENTER>.
Psion Teklogix 753
0
Hand-Held Computer User Manual 95
Chapter 5: Configuration
Keyboard Macro Keys
A message screen is displayed instructing you to ‘Please Enter Key Strokes’.
Figure 5.11 Recording A Macro
• Type the macro sequence you want to assign to the Macro key. You can type text and numbers, and you can program the function of special keys into a macro.
• When you’ve finished recording your macro sequence, press the key sequence – <CTRL> <ALT> <ENTER>.
A new screen displays the macro sequence you created. The
Save Macro
button is highlighted.
• Press <ENTER> to save your macro.
Note: If you want to discard the macro you’ve just created, press the <TAB> key to highlight the
Discard Macro
button and press <ENTER>.
Executing A Macro
To execute a macro:
• Press the macro key to which you’ve assigned the macro. For example, if you created a macro for macro key ‘1’, press <M1> to execute the macro.
96 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Unicode Mapping
Deleting A Macro
To delete a macro:
• In the
Macros
tab, use the arrow keys to highlight the macro number you want to delete.
• Press <TAB> to highlight the
Delete Macro
button, and press <ENTER>.
5.5.2.5
Unicode Mapping
• In the Keyboard Properties dialogue box, open the Unicode Mapping tab.
Figure 5.12 Unicode Mapping
The
Unicode Mapping
tab is used to map combinations of virtual key values and
<CTRL> and <SHIFT> states to Unicode™ values. This tab shows the configured
Unicode character along with the Unicode value. For example, the sample screen above shows “a (U+0061)” indicating that the character “a” is represented by the
Unicode value “0061”, and so on. Keep in mind that Unicode configurations are represented as hexidecimal rather than decimal values.
All user-defined Unicode mappings are listed in the
Unicode Mapping
tab in order of virtual key value, and then by order of the shift state. If a Unicode mapping is not listed, the Unicode mapping is mapped to the default Unicode value.
Psion Teklogix 753
0
Hand-Held Computer User Manual 97
Chapter 5: Configuration
Unicode Mapping
Adding And Changing Unicode Values
Important: Changes to Unicode mappings are not saved until you exit the
Keyboard Properties
dialogue box.
• Press <TAB> to highlight the
Add/Change
button, and press <ENTER>.
Figure 5.13 Adding And Change Unicode Values
• Highlight the a value in the Unicode mapping list – in the sample screen above, a value will be assigned to virtual key 0 (VK 0).
• Press <TAB> to position the cursor in the ‘Unicode Mapping’ field and type a Unicode value for the highlighted key.
Note: To add a shifted state – <SHIFT> and/or <CTRL>, press <TAB> to position the cursor in the checkbox next to ‘SHIFT Pressed’ and/or ‘CTRL
Pressed’. Press <SPACE> to select (
√
) the shift state you want to assign.
Removing Unicode Values
• In the ‘Unicode Mapping’ tab, highlight the item you want to delete, and press <TAB> to highlight the
Remove
button.
• Press <ENTER> to delete the value.
98 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Volume And Sound Properties
5.5.3 Volume And Sound Properties
Note: Sounds (wave files) cannot be reproduced on 753 0 units. The conditions under which 753 0 s emit sounds are tailored from within the application installed on your unit.
• In the
Control Panel
, choose the
Volume & Sounds
icon.
Figure 5.14 Choosing The Volume Icon
5.5.3.1
Volume Adjustments
Figure 5.15 Volume Settings
• Slide the volume button to the left to lower the beeper volume or to the right to increase the beeper volume.
• Under the heading
‘Enable sounds for:’
, enable (
√
) the conditions under which you want the 7530 to emit a beep.
Psion Teklogix 753
0
Hand-Held Computer User Manual 99
Chapter 5: Configuration
Power Management Properties
5.5.4 Power Management Properties
This icon displays a Power Properties dialogue box that indicates the unit’s battery capacity and allows you to manage battery use.
• In the
Control Panel
, choose the
Power
icon.
Figure 5.16 Choosing The Power Icon
5.5.4.1
Battery Capacity
• In the Power Properties dialogue box, open the Battery tab.
Figure 5.17 Power Battery Properties
The
Battery
tab details information about the battery installed in your 7530.
100 Psion Teklogix 753
0
Hand-Held Computer User Manual
5.5.4.2
Power Saving Schemes
• In the Power Properties dialogue box, open the Schemes tab.
Chapter 5: Configuration
Power Saving Schemes
Figure 5.18 Power Scheme Properties
Power Scheme
This dropdown menu allows you to specify whether the unit is using
AC Power
or
Battery Power
.
Switch State To Suspend
Important: Psion Teklogix recommends setting the Suspend value to 10 minutes. Setting ‘Switch State To Suspend’ to ‘Never’ will adversely affect the battery run time.
To further reduce power consumption, carefully consider the duration of time that the display backlight is ‘on’ (see “Display
Backlight” on page 89).
When the 7530 is idle – not receiving any user input (a key touch, a scan, and so on) or system activity (serial data, an activity initiated by an application, and so on), the hand-held uses the value assigned in the
Switch State To Suspend
field to determine when the unit will go to sleep (appear to be off).
When the time in the
Suspend
field elapses without any activity, the unit enters
Suspend
state. In
Suspend
state, the 7530 CPU enters a sleep state, and the radio is shut off. The state of the device (RAM contents) is preserved. Pressing <ENTER> wakes the system from suspend state. When the 7530 is in suspend state, the network connection will not be broken immediately. If the connection is dropped, you must re-establish the network connection.
Psion Teklogix 753
0
Hand-Held Computer User Manual 101
Chapter 5: Configuration
Suspend Threshold
5.5.4.3
Suspend Threshold
• In the Power Properties dialogue box, open the Suspend Threshold tab.
Figure 5.19 Suspend Threshold Properties
Suspend Threshold
The sliding bar in this tab is used to set the battery capacity (as a percentage value) at which the hand-held will be forced into a suspend state. For example, if you slide the bar in the
Suspend Threshold
tab to the right to the 10% level, when the battery capacity falls to 10%, the 7530 will enter suspend state. You will not be able to resume until the battery is charged, or you operate the 7530 using AC power. The allowable threshold ranges from 0 to 50%. The default value is 0%.
Note: The753 0 hand-held does not enter suspend state when it is using
AC power.
Main Battery Status
This field indicates the status of the main battery.
Estimated Operating Time
This field estimates the length of time the 7530 can remain ‘on’ (operating) before reaching the configured
Suspend Threshold
.
Estimated Battery Backup Time
This field displays the amount of time the state of the 7530 will be maintained in
suspend at the currently configured
Suspend Threshold
.
102 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Charger Details
5.5.4.4
Charger Details
• In the Power Properties dialogue box, open the Charger tab.
When the 7530 is in a Combo Dock, enabling (
√
)
Allow Battery Calibration
in this tab allows a battery requiring recalibration to be fully discharged and recharged.
Recalibration occasionally extends the battery charge time. If you prefer that the battery always be charged in the shortest time possible, do not check this box.
5.5.5 Stylus Properties
Note: Touchscreen calibration may not be enabled on your unit. If your screen appears to require recalibration, contact your supervisor.
• In the Control Panel , choose the Stylus icon.
Figure 5.20 Stylus Icon
Psion Teklogix 753
0
Hand-Held Computer User Manual 103
Chapter 5: Configuration
Setting Double-Tap Sensitivity
5.5.5.1
Setting Double-Tap Sensitivity
• In the
Double-Tap
tab, follow the directions to tailor the sensitivity of the stylus when you tap on the touchscreen.
Figure 5.21 Setting Stylus Sensitivity
5.5.5.2
Touchscreen Calibration
Touchscreens rarely require recalibration. However, if your touchscreen has never been calibrated or if you find that the stylus pointer is not accurate when you tap on an item, follow the directions below.
• Choose the Calibration tab and then tap on the Recalibrate button.
Figure 5.22 Calibrating The Touchscreen
• Follow the directions in the
Calibration
tab to recalibrate the screen.
104 Psion Teklogix 753
0
Hand-Held Computer User Manual
5.5.6 Certificate Assignment
• In the Control Panel , choose the Certificate icon.
Chapter 5: Configuration
Certificate Assignment
The dialogue box is used in conjunction with 802.1x authentication to enhance 7530 security.
Figure 5.23 Certificates Dialogue Box
For a detailed description about
Certificate
setup for both the server and client-side devices (7530s), refer to the following website:
www.microsoft.com/windows2000/techinfo/planning/walkthroughs/default.asp - "Security Services"
Note: When importing certificates, the 753 0 only recognizes .cer files.
Psion Teklogix 753
0
Hand-Held Computer User Manual 105
5.7 Scanner Properties Setup
The
Teklogix Scanners
icon in the
Control Panel
provides dialogue boxes in which you can tailor bar code options and choose the bar codes your scanner will recognize.
5.7.1 Scanner Options
Figure 5.45 Bar Code Options
To display the sub-menus available in the
Options
tab:
• Highlight the option you want to work with, and press the right
<ARROW> key.
To change a parameter:
• Highlight the parameter and press the <RIGHT> arrow key, or press the
<SPACE> key.
If a field requires text entry, a text field is displayed in which you can type the appropriate value.
Display Parameters
Scan Result
When this parameter is enabled (set to ‘ON’), the type of bar code and the result of the scan appear on the screen. Note that this information is only displayed after a successful decode and is visible only while the scanner trigger is pressed. When the trigger is released, this information is cleared from the screen.
Chapter 5: Configuration
Scanner Options
Scan Indicator
When this parameter is enabled (set to ‘ON’), the laser warning logo appears on the display whenever the scanner is activated.
Scan Result Time (sec)
The value assigned to the “Scan Result Time (sec)” parameter determines how long the scan results of a successful scan are displayed on the screen. Time is measured in seconds, and a value of “0” (zero) disables the parameter.
Note: To remove the scan result from the screen before the “Result Time” has expired, point the scanner away from the bar code and press the trigger.
Scan Beep
This parameter determines whether or not the 7530 emits an audible scanner ‘beep’ when a scan is performed. Set this parameter to either ‘ON’ to enable the beeper or
‘OFF’ to disable it.
Scan Log File
If this parameter is enabled, the input barcode and the modified/translated output bar code are logged in the file \Flash Disk\ScanLog.txt. Keep in mind that if the ‘Scan
Log File’ is enabled, there is a slight performance effect when performing multiple scans since the log file is written to persistent storage.
Double Click Parameters
Click Time (msec)
This parameter controls the maximum gap time (in milliseconds) for a double-click.
If the time between the first and second clicks of the scanner trigger is within this time, it is considered a double-click. The allowable range is 0 to 1000 . A value of zero disables this feature.
A double-click produces different results depending on whether or not a value is assigned in the “Click Data” parameter. When a value is not assigned for the “Click
Data”, double-clicking the scanner trigger overrides the target dot delay set in the
“Dot Time” parameter and initiates a normal scan sweep. If a value is assigned for the “Click Data” parameter, double-clicking the scanner trigger inserts the “Click
Data” value rather than initiating a scan.
Psion Teklogix 753
0
Hand-Held Computer User Manual 119
Chapter 5: Configuration
Scanner Options
Click Data
For both integrated and external scanners, this parameter determines which character is sent to the application installed in your 7530 following a double-click.
A dialogue box appears, asking that you press the key you want to insert. The
ASCII/Unicode key value of the keypress is displayed.
Pressing the <ESC> key in this dialogue box resets the data to zero.
Options
Dot Time (msec)
The value selected for “Dot Time (msec)” determines (in milliseconds) how long the targeting dot remains on before the scanner switches to a normal scan sweep. The allowable values are: 0, 0.1, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 seconds. A value of 0 (zero) disables the target dot.
Short Code
When enabled (set to ‘ON’), this parameter allows scanning of short I 2 of 5 bar codes (2 characters). When disabled, these short bar codes are rejected.
Enabling “Short Code” may reduce the robustness of the decoding since the
7530 must decode more potential bar codes; it is therefore not recommended for general-purpose bar codes with 4 or more characters.
Verify
The value entered for this parameter determines the number of correct additional decodes required after the initial decode before a bar code is accepted. Higher values significantly increase the time it takes to decode a bar code but also improve the reliability of the decoded bar code.
Security
This parameter controls the tolerance for decoding edge-to-edge bar codes
(Code 93, Code 128, UPC/EAN). Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the bar code. The default value of
30 is generally a good compromise setting.
120 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Bar Codes
5.7.2 Bar Codes
Figure 5.46 Bar Code Selection
All the available bar code symbologies can be selected from this menu.
Important: To improve the decode speed and performance, enable (set to
‘ON’) only those codes that are required by the application.
Keep in mind that some bar code types are only available when an internal imaging scanner is installed. The bar code settings do not affect the operation of internal or external decoded scanners. These scanners must be configured by scanning special configuration bar codes. These configuration bar codes affect the communication speed or data format between the scanner and the 7530 and must not be changed.
The scanner manufacturer provides programming manuals for configuration purposes.
• For Symbol, refer to “Programming Guide P300”.
• For PSC, refer to “Powerscan Programing guide (PSC)”.
Psion Teklogix 753
0
Hand-Held Computer User Manual 121
Chapter 5: Configuration
Code 39 Settings
Figure 5.47 Code 39 Bar Code Settings
A ‘plus’ sign (+) to the left of the each bar code listed in this
Barcodes
tab indicate that that a sub-menu of parameters is attached. To work with a sub-menu:
• Highlight the bar code you want to work with, and press the <RIGHT> arrow key to display the sub-menu.
• Use the <UP> and <DOWN> arrow keys to highlight a parameter.
• To change a parameter value, press <SPACE> or the <RIGHT> arrow key.
If a field requires text entry, a text box is displayed in which you can enter the appropriate value.
5.7.2.1
Code 39 Settings
Full Ascii
If this parameter is enabled (set to ‘ON’), the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character.
Include Check
If this parameter is enabled (set to ‘ON’), the check digit is included with the decoded bar code data.
122 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Code 39 Settings
AIAG Strip
If this parameter is enabled (set to ‘ON’), the AIAG data identifier is removed from each decoded Code 39 label. The data identifier occurs in the first position next to the Code 39 start character. It can be a single alphabetic character or a series of numeric digits followed by an alphabetic character. This identifier defines the general category or specific use of the data contained in the rest of the bar code.
Note: If your unit is operating with the Psion Teklogix TESS application, this parameter should not be used in conjunction with the TESS AIAG feature.
This is because the 753 0 hand-held performs the strip function before it processes the data through the AIAG feature; if the prefix is stripped, the data is not identified as AIAG.
Error Accept
If the “Err Accept” and “AIAG Strip” parameters are enabled (set to ‘ON’), all label data without an AIAG identifier character is accepted. If the “Err Accept” parameter is disabled and the “AIAG Strip” parameter is enabled (set to ‘ON’), the label data is not accepted.
Mod Checks
Mod 43 Check
If this parameter is enabled (set to ‘ON’), the Mod 43 check digit is calculated.
Mod 10 Check
If this parameter is enabled (set to ‘ON’), the Mod 10 check digit is calculated.
None
If you choose ‘None’, a check is not executed.
Field Size/Chars
Field Size
The field size is the length of the field after the first character is stripped and the prefix and suffix characters are added. If the field size is non-zero, only bar codes of that length are passed through.
Psion Teklogix 753
0
Hand-Held Computer User Manual 123
Chapter 5: Configuration
Code 128 Settings
Prefix Char
This character, if non-zero, is added before a successfully decoded bar code. Press the key you want to insert in the dialogue box attached to this parameter. The
ASCII/Unicode key value of the keypress is displayed.
Pressing the <ESC> key in this dialogue box resets the data to zero.
Suffix Char
Note: The appended character is treated as any other keyboard character.
For example, if <BKSP> is pressed, the usual action for that key is performed. If your unit is operating with the Psion Teklogix ANSI emulation application, the 753 0 transmits the escape sequence associated with the function immediately after the bar code data.
This character, if non-zero, is added after a successfully decoded bar code. Press the key you want to insert in the dialogue box attached to this parameter. The
ASCII/Unicode key value of the keypress is displayed.
Pressing the <ESC> key in this dialogue box resets the data to zero.
Strip Leading
This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added.
Note: For Code 39 bar codes, the “AIAG Strip” is performed before the
“Strip Leading”.
Strip Trailing
The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.
5.7.2.2
Code 128 Settings
Include Sym
Setting “Include Sym” to ‘ON’ causes the group separator(s) and start code contained in this type of bar code to be displayed on the screen.
Note: This option is available only when ‘EAN/UCC 128’ is selected.
124 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
EAN 13 Settings
Variations
When using Code 128, you can choose the variation or type of bar code variation the scanner will recognize. The options available are Standard , UCC and EAN/UCC .
These options are described below.
Standard
Enable (set to ‘ON’) “Standard” if Code 128 is desired.
UCC 128
“UCC” is a variation of Code 128.
EAN/UCC 128
To successfully scan this type of bar code, “EAN/UCC” must be enabled (set to
‘ON’). “EAN/UCC” bar codes include group separators and start codes.
Field Size/Chars
Refer to the description beginning on page 123 for details.
5.7.2.3
EAN 13 Settings
Include Country
If this parameter is enabled (set to ‘ON’), the country code is included with the decoded bar code data.
Include Check
If this parameter is enabled (set to ‘ON’), the check digit is included with the decoded bar code data.
Addendum
Important: Before “Addendum” can take effect, the “Short Code” parameter
in the Options menu (see page 120) must be enabled (set to ‘ON’).
An addendum is a separate bar code, supplementary to the main bar code.
This parameter provides three options: Disabled, Optional and Required .
Depending on the value chosen for this parameter, an addendum is recognized or ignored.
Psion Teklogix 753
0
Hand-Held Computer User Manual 125
Chapter 5: Configuration
EAN 8
When “Addendum” is set to Disabled, the scanner does not recognize an addendum. If this parameter is set to Optional, the scanner searches for an addendum and if one exists, appends it to the main bar code. When the parameter is set to Required, the scanner does not accept the main bar code without an addendum.
Prefix/Suffix
Prefix Char
This character, if non-zero, is added before a successfully decoded bar code. Press the key you want to insert in the dialogue box attached to this parameter. The
ASCII/Unicode key value of the keypress is displayed.
Pressing the <ESC> key in this dialogue box resets the data to zero.
Suffix Char
This character, if non-zero, is added after a successfully decoded bar code. Press the key you want to insert in the dialogue box attached to this parameter. The
ASCII/Unicode key value of the keypress is displayed.
Pressing the <ESC> key in this dialogue box resets the data to zero.
Strip Leading
This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added.
Note: The appended character is treated as any other keyboard character. For example, if <BKSP> is pressed, the usual action for that key is performed. If your 753 0 is operating with the Psion Teklogix ANSI emulation application, the hand-held transmits the escape sequence associated with the function immediately after the bar code data.
Strip Trailing
The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.
5.7.2.4
EAN 8
Include Check
If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
126 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
UPC And EAN Settings
Addendum
Important: Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 120) must be enabled (set to ‘ON’).
Refer to “Addendum” on page 125.
Prefix/Suffix
See “Size/Chars” beginning on page 126.
5.7.2.5
UPC And EAN Settings
Field Size/Char
Refer to page 123 for details.
5.7.2.6
UPC A Settings
Include Number Sys
If this parameter is enabled (set to ‘ON’), the number system digit is included with the decoded bar code data.
Include Check
If this parameter is enabled (set to ‘ON’), the check digit will be included with the decoded bar code data.
Addendum
Important: Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 120) must be enabled (set to ‘ON’).
Refer to “Addendum” on page 125.
Prefix/Suffix
Refer to page 126 for details.
5.7.2.7
UPC E Settings
Convert to UPC-A
Setting this parameter to ‘ON’ results in a non-standard decoding that returns 12 digits from the 6 digit UPC E bar code.
Psion Teklogix 753
0
Hand-Held Computer User Manual 127
Chapter 5: Configuration
Codabar
Include Number Sys
If this parameter is enabled (set to ‘ON’), the number system digit is included with the decoded bar code data.
Include Check
When enabled (set to ‘ON’), the check digit is included with the decoded bar code data.
Addendum
Important: Before “Addendum” can take effect, the “Short Code” parameter
in the Options menu (see page 120) must be enabled (set to ‘ON’).
Refer to “Addendum” on page 125.
Prefix/Suffix
Refer to page 126 for details.
5.7.2.8
Codabar
Field Size/Char
Refer to page 123 for details.
5.7.2.9
Code 93
Field Size/Char
Refer to page 123 for details.
5.7.2.10
Code 11
Include Check
If “Include Chk” is enabled (set to ‘ON’), the check digit is included with the decoded bar code data.
Check Digit
This parameter can be set to None , One Check Digits or Two Check Digits .
If this parameter set to One Check Digits , it is assumed that the last digit is a check digit.
If this parameter is set to Two Check Digits , it is assumed that the last two digits are check digits.
128 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Interleaved 2 of 5
Field Size/Chars
Refer to page 123 for details.
5.7.2.11
Interleaved 2 of 5
Mod 10 Chk
If this parameter is enabled (set to ‘ON’), the Mod 10 check digit is calculated. This calculation is the same as the Code 39 Mod 10 check digit.
ITF Chk
If this parameter is enabled (set to ‘ON’), the ITF-14/16 Mod10 check digit is calculated.
Include Check
If this parameter is enabled (set to ‘ON’), the check digit is included with the decoded bar code data.
Field Size/Chars
Refer to page 123 for details.
5.7.2.12
MSI Plessey
One Check Digit
If this parameter is enabled (set to ‘ON’), it is assumed that the last digit is a check digit.
Include Check
If this parameter is enabled (set to ‘ON’), the check digit is included with the decoded bar code data.
Field Size/Chars
Refer to page 123 for details.
5.7.2.13
Discrete 2 of 5
Mod 10 Check
If this parameter is enabled (set to ‘ON’), the Mod 10 check digit is calculated. This calculation is the same as the Code 39 Mod 10 check digit.
Psion Teklogix 753
0
Hand-Held Computer User Manual 129
Chapter 5: Configuration
IATA 2 of 5
ITF Check
If this parameter is enabled (set to ‘ON’), the ITF-14/16 Mod10 check digit is calculated.
Include Check
If this parameter is enabled (set to ‘ON’), the check digit is included with the decoded bar code data.
Field Size/Chars
Refer to page 123 for details.
5.7.2.14
IATA 2 of 5
Mod 10 Check
If this parameter is enabled (set to ‘ON’), the Mod 10 check digit is calculated.
ITF Check
If this parameter is enabled (set to ‘ON’), the ITF-14/16 Mod10 check digit is calculated.
Include Check
If this parameter is enabled (set to ‘ON’), the check digit is included with the decoded bar code data.
Field Size/Chars
Refer to page 123 for details.
5.7.2.15
Postal: Australian
Size/Chars
Refer to page 123 for details.
5.7.2.16
Postal: Japanese
Size/Chars
Refer to page 123 for details.
5.7.2.17
Postal: Korean
Size/Chars
Refer to page 123 for details.
130 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Postal: PlaNET
5.7.2.18
Postal: PlaNET
Size/Chars
Refer to page 123 for details.
5.7.2.19
Postal: PostNET
Size/Chars
Refer to page 123 for details.
5.7.2.20
Postal: Royal Mail
Size/Chars
Refer to page 123 for details.
5.7.2.21
2D DataMatrix
Inverse Video
If enabled (set to ‘ON’), this parameter allows symbols that contain light cells on a dark background to be decoded.
Rectangular Symbols
When enabled (set to ‘ON’), this parameter allows rectangular DataMatrix symbols to be decoded.
Small Symbols
If enabled (set to ‘ON’), DataMatrix symbols of small physical size can be successfully decoded.
Field Size/Chars
Refer to page 123 for details.
5.7.2.22
2D Maxicode
Field Size/Chars
Refer to page 123 for details.
5.7.2.23
2D PDF-417
Field Size/Chars
Refer to page 123 for details.
Psion Teklogix 753
0
Hand-Held Computer User Manual 131
Chapter 5: Configuration
2D Micro PDF-417
5.7.2.24
2D Micro PDF-417
Field Size/Chars
Refer to page 123 for details.
5.7.2.25
2D QR Code
Inverse Video
If enabled (set to ‘ON’), this parameter allows symbols that contain light cells on a dark background to be decoded.
Field Size/Chars
Refer to page 123 for details.
5.7.2.26
2D RSS Code
Field Size/Chars
Refer to page 123 for details.
5.7.2.27
Aztec
Field Size/Chars
Refer to page 123 for details.
5.7.3 Translations
Figure 5.48 Translation Tab
• In the
Translation
tab, choose the
Add
button.
132 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Translations
Figure 5.49 Translation Dialogue Box
Input
This value is compared with the decoded bar code reading. If there is a match, the
“Output” string is translated into the decoded bar code.
Output
If there is a match between the decoded bar code and the corresponding “Input” string, the decoded bar code will be translated into the “Output” string. This string entry parameter can be null, or it may contain any combination of standard and special characters (e.g., function keys, <ENTER>, etc.).
Type
The value chosen from this dropdown menu determines what is compared with the decoded bar code reading – the beginning of decoded bar code, the end of decoded bar code, the entire decoded bar code or anywhere within the decoded bar code
(default).
Psion Teklogix 753
0
Hand-Held Computer User Manual 133
Chapter 5: Configuration
SNMP (Simple Network Management Protocol) Setup
5.8 SNMP (Simple Network Management Protocol) Setup
Simple Network Management Protocol (SNMP) is the protocol used to monitor and manage devices attached to a TCP/IP network (providing they support SNMP).
SNMP uses Management Information Bases (MIBs) that define the variables an
SNMP Network Management Station can access. Each product has a defined set of
MIBs that determine how SNMP operates, the type of access allowed and so on.
All Teklogix products support the TEKLOGIX-GENERIC-MIB – a MIB that defines some common features across Teklogix products. All devices also support
MIB-II, a management information base that defines the common features of
TCP/IP networks. The SNMP Agent software embedded in the 7530 product supports SNMPv1 (RFC 1157).
• In the
Control Panel
, choose the
SNMP
icon.
Figure 5.50 SNMP Icon
134 Psion Teklogix 753
0
Hand-Held Computer User Manual
5.8.1 Contact Tab
The
SNMP
dialogue box is displayed.
Chapter 5: Configuration
Contact Tab
Figure 5.51 Contact Tab
Contact
This field identifies the contact person for this managed node along with information about how to get in touch with this person. The content of this parameter is accessible through MIB-II’s sysContact object.
Location
This parameter is used to identify the physical location of this node (e.g., Warehouse
A: Pillar 32B). The content of this parameter is accessible through MIB-II’s sysLocation object.
Psion Teklogix 753
0
Hand-Held Computer User Manual 135
Chapter 5: Configuration
Communities Tab
5.8.2 Communities Tab
Figure 5.52 Community Settings
The “Communities” tab provides a means of limiting access to SNMP managed devices to those SNMP Managers with matching “community names”, as specified by RFC 1157.
Enable SNMP
Enabling (
√
) ‘
Enable SNMP
’ allows the device to respond to SNMP queries and to send
Traps. After enabling this option and rebooting the device, the SNMP Agent will automatically start up. To disable this feature, remove the check mark from the check box.
136 Psion Teklogix 753
0
Hand-Held Computer User Manual
5.8.2.1
Adding A Community
• Choose the
Add
button to add a new ‘community’.
Chapter 5: Configuration
Adding A Community
Figure 5.53 Adding A Community
Name
The value assigned here is the name assigned by the network administrator to the set of devices to which this managed node belongs.
Rights
This menu allows you to specify access – that is, ‘Read-Only’ or Read-Write’
Psion Teklogix 753
0
Hand-Held Computer User Manual 137
Chapter 5: Configuration
Modifying A Community Setting
5.8.2.2
Modifying A Community Setting
To modify an existing community:
• Highlight the community you want to alter.
• Choose the
Change
button.
Figure 5.54 Changing Or Removing A Community
A
Modify Community
dialogue box is displayed, listing the community you highlighted.
• Edit the
Name
and/or
Rights
, and press <ENTER> to save your changes.
5.8.2.3
Removing An Existing Community
To remove an item:
• Highlight the community you want to remove in the
Communities
tab and then choose the
Remove
button.
A
Delete Confirmation
screen is displayed.
• To remove a community, choose the
Yes
button.
• If you decide not to remove the community, choose the
No
button.
138 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Trap Destination Tab
5.8.3 Trap Destination Tab
A trap is an unsolicited report sent to SNMP Managers by the SNMP Agent running on the managed node. This option allows you to define where the report will be sent.
Figure 5.55 Trap Destination Tab
5.8.3.1
Enabling Authentication TRAPS
Enabling (
√
)
‘Enable Authentication TRAPS’
allows authorization traps to be sent when a failure is detected (e.g., an SNMP message received with a bad community name).
5.8.3.2
Adding A Destination
To add a new destination:
• Choose the
Add
button.
Figure 5.56 Adding A Trap Destination
• Type a destination in the text box provided, and press <ENTER>.
Psion Teklogix 753
0
Hand-Held Computer User Manual 139
Chapter 5: Configuration
Changing A Destination
5.8.3.3
Changing A Destination
To change an existing trap destination:
• Highlight the destination you want to alter in the
Trap Destination
tab, and then choose the
Change
button.
A dialogue box like the one displayed when you add a destination is displayed.
Figure 5.57 Changing A Destination
• Make the changes to the destination, and press <ENTER> to save the changes.
5.8.3.4
Removing A Trap Destination
To remove a trap destination:
• In the
Trap Destination
tab, highlight the destination you want to delete.
• Choose the
Remove
button.
A
Delete Confirmation
screen is displayed.
• To remove a destination, choose the
Yes
button.
• If you decide not to remove the destination, choose the
No
button.
140 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 5: Configuration
Permitted Hosts Tab
5.8.4 Permitted Hosts Tab
For security reasons, the Network Administrator may want to restrict SNMP-node access to a known sub-set of SNMP Managers. This tab lists the IP addresses of all the SNMP Managers which are allowed to monitor and manage this device. If no entries are listed, the device will accept SNMP queries from any host.
Figure 5.58 Permitted Hosts Tab
5.8.4.1
Adding A Host
To add a new host:
• Highlight the
Add
button, and press <ENTER>.
Figure 5.59 Adding A Host
• Type a new host IP address in the text box provided, and press <ENTER>.
Psion Teklogix 753
0
Hand-Held Computer User Manual 141
Chapter 5: Configuration
Changing A Host
5.8.4.2
Changing A Host
To change an existing host IP address:
• Highlight the IP address you want to alter in the
Permitted Hosts
tab, and then choose the
Change
button.
A dialogue box like the one displayed when you add a host is displayed.
• Make the necessary changes, and press <ENTER>.
142 Psion Teklogix 753
0
Hand-Held Computer User Manual
T
EKTERM
A
PPLICATION
6.1 The Tekterm Application . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
6.2 Additional Keyboard Functions . . . . . . . . . . . . . . . . . . . . . . . 147
6.2.1 Function Keys And Softkeys. . . . . . . . . . . . . . . . . . . . . . 147
6.2.1.1 Function Keys . . . . . . . . . . . . . . . . . . . . . . . . .147
6.2.1.2 Softkey Function Keys . . . . . . . . . . . . . . . . . . . . .148
6.2.2 Macro Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
6.3 Keyboard Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
6.3.1 View Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
6.3.1.1 Changing Font Sizes . . . . . . . . . . . . . . . . . . . . . .150
6.3.1.2 Panning The Screen Contents . . . . . . . . . . . . . . . . .150
6.3.1.3 Exiting View Mode . . . . . . . . . . . . . . . . . . . . . . .151
6.3.2 Using The Task Manager To Switch Between Applications. . . . . . 152
6.4 The Tekterm Status Area . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
6.5 TESS Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
6.5.1 Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
6.5.2 Working With Multiple Sessions. . . . . . . . . . . . . . . . . . . . 154
6.5.3 The Field Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
6.5.4 IBM 5250 Emulation Keys . . . . . . . . . . . . . . . . . . . . . . 155
6.5.5 Data Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
6.5.5.1 TESS Edit Modes And Cursor Movement . . . . . . . . . . .156
6.5.5.2 <DEL> Key Behaviour In TESS . . . . . . . . . . . . . . . .157
6.5.5.3 <BKSP> Key Behaviour In TESS . . . . . . . . . . . . . . .158
6.5.6 TESS Status Message . . . . . . . . . . . . . . . . . . . . . . . . . 159
6.5.7 Lock Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
6.5.8 Control Commands . . . . . . . . . . . . . . . . . . . . . . . . . . 160
6.5.9 Resetting A TESS Session . . . . . . . . . . . . . . . . . . . . . . . 160
6.5.10 The Local Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
6.5.11 Selecting Another Host Computer . . . . . . . . . . . . . . . . . . 161
6.5.12 Queuing Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
6.6 ANSI Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
6.6.1 Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
6.6.2 Sending Data To The Host . . . . . . . . . . . . . . . . . . . . . . . 163
6.6.3 Psion Teklogix Keyboard And VT220 Equivalent Keys . . . . . . . . 163
Psion Teklogix 753
0
Hand-Held Computer User Manual 143
6.6.4 Block Mode (Local Editing) . . . . . . . . . . . . . . . . . . . . . .164
6.6.5 Working With Sessions . . . . . . . . . . . . . . . . . . . . . . . . .165
6.6.5.1 Establishing A New Session . . . . . . . . . . . . . . . . . 165
6.6.5.2 Listing Sessions And Moving To Other Sessions. . . . . . . 165
6.6.5.3 Closing A Session . . . . . . . . . . . . . . . . . . . . . . . 165
6.6.5.4 Printing A Screen . . . . . . . . . . . . . . . . . . . . . . . 166
6.6.5.5 Smart Echo – Disabling . . . . . . . . . . . . . . . . . . . . 166
6.8 The Tekterm Startup Display Menu. . . . . . . . . . . . . . . . . . . . . .168
6.9 Working With Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
6.9.1 Using The Keyboard To Navigate Through Menus . . . . . . . . . .170
6.9.1.1 Sub-Menus . . . . . . . . . . . . . . . . . . . . . . . . . . 170
6.9.1.2 Numeric Parameters. . . . . . . . . . . . . . . . . . . . . . 170
6.9.1.3 Y/N Parameters . . . . . . . . . . . . . . . . . . . . . . . . 171
6.9.1.4 Alpha Parameters . . . . . . . . . . . . . . . . . . . . . . . 171
6.9.1.5 String Entry Parameters . . . . . . . . . . . . . . . . . . . . 171
6.9.2 Using The Touchscreen To Navigate Through Menus . . . . . . . . .173
6.9.2.1 Sub-Menus . . . . . . . . . . . . . . . . . . . . . . . . . . 173
6.9.2.2 Numeric Parameters. . . . . . . . . . . . . . . . . . . . . . 174
6.9.2.3 Y/N Parameters . . . . . . . . . . . . . . . . . . . . . . . . 174
6.9.2.4 Alpha Parameters . . . . . . . . . . . . . . . . . . . . . . . 174
6.9.2.5 String Entry Parameters . . . . . . . . . . . . . . . . . . . . 174
6.9.3 Saving Changes To Parameters . . . . . . . . . . . . . . . . . . . . .175
6.9.4 Retrieving Default Parameter Values . . . . . . . . . . . . . . . . . .175
6.10 Resetting The 7530 Hand-Held Computer . . . . . . . . . . . . . . . . .175
6.11 The Parameters Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
6.11.1 Security Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . .176
6.12 Display Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
6.13 More Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
6.14 Radio Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179
6.15 System Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
6.15.1 Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
6.15.1.1 Macro Control Panel. . . . . . . . . . . . . . . . . . . . . 181
6.15.1.2 Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . 182
6.15.1.3 Softkeys . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
6.15.1.4 Ctrl Panel . . . . . . . . . . . . . . . . . . . . . . . . . . 182
6.15.2 Audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
6.15.3 Power Mgmt Ctrl Panel . . . . . . . . . . . . . . . . . . . . . . . .184
6.15.4 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
6.15.4.1 Default Mode . . . . . . . . . . . . . . . . . . . . . . . . 185
6.15.4.2 User Level Options . . . . . . . . . . . . . . . . . . . . . 185
6.15.4.3 Sup. Password . . . . . . . . . . . . . . . . . . . . . . . . 186
6.15.4.4 Allow Teklogix. . . . . . . . . . . . . . . . . . . . . . . . 186
144 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 6: Tekterm Application
6.16 Scanner Control Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
6.17 View Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
6.17.1 Split Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
6.17.1.1 Splitting And Displaying Screens. . . . . . . . . . . . . . .189
6.17.1.2 Moving Between Split Screens . . . . . . . . . . . . . . . .190
6.17.1.3 Toggling Between Full & Split Screens . . . . . . . . . . .190
6.17.1.4 Using The Asterisk As A Wild Card . . . . . . . . . . . . .190
6.17.2 Custom Characters (Unicode™) . . . . . . . . . . . . . . . . . . . 191
6.17.2.1 Creating A Unicode™ Character . . . . . . . . . . . . . . .191
6.17.2.2 Displaying The Unicode™ Pop-up Window . . . . . . . . .192
6.18 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
6.18.1 ANSI Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
6.18.1.1 Host Conn . . . . . . . . . . . . . . . . . . . . . . . . . . .196
6.18.1.2 Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199
6.18.1.3 Xmit Modes . . . . . . . . . . . . . . . . . . . . . . . . . .202
6.18.1.4 Kbd Modes . . . . . . . . . . . . . . . . . . . . . . . . . .206
6.18.1.5 Edit Modes . . . . . . . . . . . . . . . . . . . . . . . . . .209
6.18.1.6 Serial . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210
6.18.1.7 Host Char Set . . . . . . . . . . . . . . . . . . . . . . . . .210
6.18.1.8 Anchor View . . . . . . . . . . . . . . . . . . . . . . . . .211
6.18.2 TESS Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
6.18.2.1 Host Conn. . . . . . . . . . . . . . . . . . . . . . . . . . .213
6.18.2.2 Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214
6.18.2.3 Characters . . . . . . . . . . . . . . . . . . . . . . . . . . .216
6.18.2.4 Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218
6.18.2.5 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . .219
6.18.2.6 Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . .223
6.18.2.7 Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224
6.18.2.8 Anchor View . . . . . . . . . . . . . . . . . . . . . . . . .227
6.18.2.9 Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . .227
6.19 Ports– Tether And Console . . . . . . . . . . . . . . . . . . . . . . . . . 235
6.19.1 Tether And Console Port Peripheral Options . . . . . . . . . . . . . 235
6.19.2 Tether And Console Port Parameter Settings . . . . . . . . . . . . . 236
6.19.3 Tether And Console Port Scan-See Parameters. . . . . . . . . . . . 239
6.19.3.1 Scan-See Sub-Menu – Mapping The Viewport . . . . . . . .239
6.19.3.2 Scan-See Keyboard Mapping . . . . . . . . . . . . . . . . .244
6.20 Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
6.20.1 Network Ctrl Panel Settings . . . . . . . . . . . . . . . . . . . . . 245
6.20.2 802.IQ v2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Psion Teklogix 753
0
Hand-Held Computer User Manual 145
Chapter 6: Tekterm Application
The Tekterm Application
6.1 The Tekterm Application
Tekterm is a powerful emulation application ideally suited for real time data transaction applications associated with mainframes and servers. The 7530 includes unique features that support Tekterm – a Psion Teklogix application that has the ability to maintain multiple simultaneous sessions with a variety of host computers.
6.2 Additional Keyboard Functions
In addition to the standard keyboard functions (see “The Keyboard” on page 35),
Tekterm supports function keys, softkeys and macro keys.
6.2.1 Function Keys And Softkeys
6.2.1.1 Function Keys
The 7530 is equipped with a series of function keys each of which is defined in the application software. Depending on the type of keyboard your 7530 has – 58-key or
36-key – the number and location of the function keys on the keyboard varies slightly.
58-Key Keyboard Function Keys
The 58-key keyboard is equipped with thirty function keys. Function keys <F1> to
<F6> are located across the top of the keyboard and are directly accessible – a key combination is not required. Function keys <F7> to <F30> are colour coded in blue print above the alpha keys and are accessed using a key combination – <BLUE> followed by the appropriate alpha key.
To access function keys <F7> to <F30>:
• Press the <BLUE> key followed by the alpha key to which the function key you want to use is mapped. For example:
To access function key <F7>, press <BLUE> <C>.
To access function key <F8>, press <BLUE> <D>, and so on.
36-Key Keyboard Function Keys
The 36-key keyboard is equipped with thirty function keys. Function keys <F1> to
<F4> are located across the top of the keyboard and function keys <F5> to <F10> are located at the bottom of the keyboard.
Psion Teklogix 753
0
Hand-Held Computer User Manual 147
Chapter 6: Tekterm Application
Softkey Function Keys
Additional function keys – <F11> to <F20> – are colour coded in orange print above function keys <F1> to <F10>.
To access function keys <F11> to <F20>:
• Press the <ORANGE> key followed by the appropriate function key.
For example:
To access function key <F11>, press the <ORANGE> key followed by <F1>.
To access function key <F12>, press <ORANGE> followed by <F2>, and so on.
To access function keys <F21> to <F30>, you’ll need to press <SHIFT> <F1> to
<F10>.
To access function keys <F21> to <F30>:
• Press the <SHIFT> key followed by the appropriate function key.
For example:
To access function key <F21>, press the <SHIFT> key followed by <F1>.
To access function key <F22>, press <SHIFT> followed by <F2>, and so on.
6.2.1.2 Softkey Function Keys
To speed the process of moving through menus and changing parameters, function keys <F1> to <F5> have been programmed to perform specific actions in the
Tekterm menus. Table 6.1 describes these function keys.
These softkeys can be reprogrammed to perform different functions within TESS and ANSI applications.
Important: If your 753 0 is equipped with a touchscreen, tapping the stylus on the appropriate softkey label executes the function of the softkey providing that the labels are visible at the bottom of the 753 0 screen. See “Softkeys” on page 182 if they are not visible.
Function Key
<F1>
<F2>
<F3>
Softkey Function
NEXT – Displays the next sub-menu
PREV – Displays the previous menu.
DEFLT – Restores parameters to default settings – even after pressing <F4> to save the changes.
148 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 6: Tekterm Application
Macro Keys
<F4>
<F5>
SAVE – Saves a change to a parameter value.
LITRL – Literal mode allows special characters to be entered in a string parameter such as macro key strings.
Table 6.1 Softkeys
Note: The SAVE onscreen label only appears when a parameter value has been changed and has not yet been saved.
6.2.2 Macro Keys
Important: Refer to “Keyboard Macro Keys” on page 95 for details about creating macros.
7530 hand-helds are equipped with a series of macro keys that can be programmed to replace frequently used keystrokes, along with the function of executable keys like the <ENTER> key, the <BKSP> key, any function key and arrow key, and so on.
58-Key Keyboard Macro Keys
7530s with 58-key keyboards have twelve macro keys – <M1> to <M12>. These keys are colour coded in orange print above alpha keys <O> to <Z>.
To access a macro key:
• Press the <ORANGE> key followed by the appropriate alpha key from
O to Z. For example:
To access macro key <M1>, press <ORANGE> <O>.
To access macro key <M2>, press <ORANGE> <P>, and so on.
36-Key Keyboard Macro Keys
36-key keyboards are equipped with six macro keys – <M1> to <M6>. Macro keys
<M1> to <M2> are directly accessible in the bottom row of the keyboard – a key combination is not required.
Macro keys <M3> and <M4> are colour coded in orange print above macro keys
<M1> and <M2>.
• To access <M3>, press the <ORANGE> key followed by <M1>
• To access <M4>, press <ORANGE> <M2>.
Psion Teklogix 753
0
Hand-Held Computer User Manual 149
Chapter 6: Tekterm Application
Keyboard Modes
Macro keys <M5> to <M6> are colour coded in blue print above macro keys <M1> and <M2>.
• To access <M5>, press the <BLUE> key followed by <M1>.
• To access <M6>, press <BLUE> <M2>.
6.3 Keyboard Modes
6.3.1 View Mode
Placing the 7530 keyboard in View mode allows you to choose another screen font and to pan the contents of the screen.
To place the computer keyboard in View mode:
• Press <CTRL> <ALT> <V>.
When the hand-held is in View mode, the onscreen message – View – is displayed in the status area at the bottom of the screen.
Keep in mind that this is a toggle key combination – pressing <CTRL> <ALT> <V> a second time turns View mode off.
6.3.1.1 Changing Font Sizes
To cycle through the available fonts (with the unit in View mode):
• Press the <F> key.
Each time you press the <F> key, the font on the screen changes. Once you’ve displayed the appropriate font:
• Press <CTRL> <ALT> <V> to exit View mode.
6.3.1.2 Panning The Screen Contents
If the content of a screen is too large to fit in the margins of the 7530 display, the content can be panned or shifted to bring the information outside the margins into view. Normally, the Arrow keys move the cursor around the screen in the direction of the arrow pressed. However, if the 7530 is operating in View mode, the <LEFT>,
<RIGHT>, <UP> and <DOWN> arrow keys pan the entire content of the screen rather than the cursor.
• Press <CTRL> <ALT> <V> to place the 7530 in View mode. An onscreen message – View – is displayed in the status area of the screen.
150 Psion Teklogix 753
0
Hand-Held Computer User Manual
Chapter 6: Tekterm Application
Exiting View Mode
Panning relies on the values set in the “Use Increment”, “X Increment” and
“Y Increment” parameters to determine the number of columns (spaces) and rows
(lines) the screen contents shift.
• In the “More Parameters” menu, position the cursor on “View Manager” and press <F1>.
• First, enable the “Use Increment” parameter – set it to “Y”.
“X Increment” determines the number of columns (spaces) the screen pans when the <LEFT> or <RIGHT> arrow key is pressed in View mode.
“Y Increment” determines the number of rows (lines) the screen pans when the
<UP> or <DOWN> arrow key is pressed in View mode.
• Assign a value to the “X Increment” and “Y Increment” parameters.
To pan the screen contents:
• Press the <RIGHT>, <LEFT>, <UP> or <DOWN> arrow key.
Note: Pressing the <LEFT> arrow pans the screen to the right, pressing the
<RIGHT> arrow pans the screen to the left, and so on.
6.3.1.3 Exiting View Mode
To exit View mode and resume normal operation:
• Press <CTRL> <ALT> <V> again.
Note: You can press the <BLUE> key followed by the appropriate arrow key each time you want to pan the contents one increment at a time in the direction of the arrow key without placing the 753 0 in View mode.
Psion Teklogix 753
0
Hand-Held Computer User Manual 151
Chapter 6: Tekterm Application
Using The Task Manager To Switch Between Applications
6.3.2 Using The Task Manager To Switch Between Applications
To display the Task Manager screen:
• Press <BLUE> <0> to display the Start Menu .
• Highlight Task Manager , and press <ENTER>, or
• Just type the underlined alpha character – in this case, the letter ‘t’.
Figure 6.1 Task Manager Screen
Note: A shortcut – to bypass the Start Menu and go directly to the
‘Task Manager’ screen, press <ALT> <ESC>.
To switch between applications:
• Highlight the application you want to work with, and press <ENTER>.
To end or close an application:
• Highlight the application you want to end, press <TAB> to highlight the
<End Task> button, and press <ENTER>.
152 Psion Teklogix 753
0
Hand-Held Computer User Manual
Download
Advertisement
Key features
Wireless LAN radio
Touchscreen
Stylus
Keyboard
Battery life up to 4 or 6 months
Frequently asked questions
The 7530 has a battery that can last for up to 4 or 6 months.
The 7530 has a wireless LAN radio that can be used to connect to a network.