EasyPro EX8800, EX11200, EX13200 water pump Installation and service manual
Below you will find brief information for water pump EX8800, water pump EX11200, water pump EX13200. These pumps are designed to provide dependable, trouble-free service for your pond. The EX8800/EX11200/EX13200 can be used for various applications around your pond, such as providing water to a waterfall, fountain, or filter system.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
EX8800 • EX11200 • EX13200
Installation and Service Manual
EasyPro
EX8800
S/N: XXXX-XXXXXX
Model
Inlet
Discharge
Max Flow (gph)
Max Head (feet)
Max Power (watts)
EX8800 EX11200 EX13200
2"
2"
8220
22.3'
2"
2"
11160
80.8'
2"
2"
13200
81.7'
450 2162 2595
Max Current (amps) 4.0 @ 115v 9.6@230v 11.5@230v
Volts
Motor HP
Motor Enclosure
Impeller
115/230
1/2
TEFC
8
230
3
TEFC
6
230
3
TEFC
7
Please fi ll in for future reference:
MODEL: ________________________________________
SERIAL NUMBER: _______________________________
DATE PURCHASED: _____________________________
* Please fi ll out the warranty registration card in this manual
MOTOR: NEMA C FACE, 56J
HORSEPOWER: 1/2 (1750 RPM), 3 (3450 RPM)
INLET: 2" FNPT AND BUTTRESS THREAD PORTS
DISCHARGE: 2" FNPT AND BUTTRESS THREAD PORTS
MATERIAL: 40% GLASS-FILLED POLYPROPYLENE
STAINLESS
OPTIONS:
ACCESORIES: 90 CUBIC INCH STRAINER BASKETS (1.5" & 2")
SWING CHECK VALVES (1.5", 2", 3")
500 CUBIC INCH STRAINER BASKETS
(1.5", 2", 3")
WARNING: Please read completely before you install or operate your new pump! This is an external “out-of-pond” pump!
It is NOT submersible! Do NOT allow this pump to become submerged! Never run dry! Max. case pressure.- 65 PSI!
Reliability You Can Count On!
© 2010 EasyPro, Inc
Pg. 1
EX8800 • EX11200 • EX13200
We congratulate you on your choice of the EX8800/EX11200/EX13200 Centrifugal Pump! It has been carefully designed using the advantages of today’s technology and carefully constructed to give you the dependability of yesterday. To insure proper performance, we urge you to carefully follow the instructions in this manual. If you have any questions, call your nearest distributor or EasyPro for assistance.
INSTALLATION
Please read carefully! When properly installed the EX8800/EX11200/EX13200 will provide dependable trouble-free service.
1. Locate the pump as near the water source as possible. A fl ooded suction situation is preferred. The pump is not self-priming, therefore, if the fl uid level is below the pump, a swing check valve must be installed and the pump primed prior to start-up. (Figure 2)
2. Mount motor base to a secure, immobile foundation.
3. Use only plastic fi ttings on both the intake and discharge ports. Seal pipe connections with Tefl on™ paste. These fi ttings should be selfsupported and in neutral alignment with each port. (i.e. Fittings must not be forced into alignment which may cause premature line failure or damage to the pump volute.) For non-fl ooded installations, a strainer basket and check valve are recommended.
4. Never restrict the intake. Keep both input and discharge lines as free of elbows and valves as possible. Always use pipe of adequate diameter. This will reduce friction losses and maximize output.
5. The EX8800 is not self-priming! It must not be run dry! We recommend a fl ooded suction installation. Please read carefully! When properly installed, the EX8800 will provide dependable, trouble-free service.
6. For additional plumbing tips, review EasyPro’s website: www.EasyProPondProducts.com for pond plumbing and pump installation hints.
BALL
VALVE
FLOODED SUCTION
SUCTION LIFT
PUMP
SWING
CHECK VALVE
WARNING: DO NOT RUN DRY!
(FIGURE 2)
WARNING: ALWAYS SHUT OFF ELECTRICAL POWER BEFORE INSTALLATION AND / OR SERVICING THIS PUMP! ALL ELECTRICAL WIRING
SHOULD MEET STATE AND LOCAL ORDINANCES. IMPROPER WIRING MAY NOT ONLY BE A SAFETY HAZARD BUT MAY PERMANENTLY
DAMAGE THE MOTOR AND/OR PUMP! 230V 50 HZ MOTORS AVAILABLE - CONTACT YOUR SUPPLIER FOR INFORMATION.
ELECTRICAL HOOK-UP
1. Check that supply voltages match the motor’s requirements.
2. Check motor wiring and connect, according to instructions on motor, to match supply voltage.
3. Power cord should be protected by conduit or by cable and be of proper gauge. It should be no longer than necessary.
4. Power should be drawn directly from a box with circuit breaker protection or with a fused disconnect switch.
Reliability You Can Count On!
© 2010 EasyPro, Inc
Pg. 2
EX8800 • EX11200 • EX13200
PUMP END ASSEMBLY
1. Clean and inspect all pump parts (O-ring, seal seats, motor shaft, etc.).
2. Apply sealant to the bracket bore ID wall and around the seal case - follow sealant manufacturer instructions. We recommend using
Gasgacinch ® . Silicone sealant can also be used.
3. Press carbon graphite seal into bracket while taking care not to damage carbon graphite face.
4. Place slinger (rubber washer) over motor shaft and mount bracket to motor.
5. Carefully, lubricate the seal seat elastomer OD and impeller hub ID with water. Press the seal seat into the impeller hub making certain that the ceramic is in evenly - the sealing surface should be parallel with the impeller hub.
6. Carefully lubricate carbon-graphite and ceramic sealing surfaces with CLEAN water. Do not use silicon lubricants or grease!
7. Assemble bracket to motor with four m-bolts
8. Thread impeller onto shaft and tighten! If required, remove motor end-cap and use a screwdriver on the back of motor shaft to prevent shaft rotation while tightening. Replace motor end cap.
9. Seat large O-ring in volute slot and assemble volute to bracket with seven 1/4-20 x 2 3/4" hex cap screws, washers and nuts. Tighten in a cross pattern (30 in-lbf).
10. Install drain plug with its O-ring in volute drain hole.
11. Before operating pump, allow a proper cure time for the sealant used in step 2.
DRAIN PLUG
& O-RING
VOLUTE
IMPELLER
SEAL
BRACKET
WASHER &
LOCK NUT
2.75
SLINGER
M-BOLT
DESCRIPTION
DRAIN PLUG
O-RING, DRAIN
PLUG
VOLUTE
LARGE O-RING
IMPELLER
SEAL - BRASS
SEAL - SS316
BRACKET
SLINGER
HARDWARE KIT
EASYPRO ®
P/N
1000.110
E014B70
4000.070
1000.061
4000.05__*
1000.0415
1000.0414
1000.030P
1000.010V
1000.502
Note: These part numbers are only for the standard model of EX8800. Reference page one for impeller number.
14.75
LARGE
O-RING
4.22
P-BOLT
& WASHER
3.50
*Motor illustration is for reference only.
DISASSEMBLY
1. Shut off power to motor before disconnecting any electrical wiring from the back of the motor.
2. Disassemble volute from bracket by removing the seven 1 /
4
" - 20 threads per inch x 2 3 /
4
" hex cap screws.
3. Remove cap covering shaft at back of motor and with a large screwdriver, prevent shaft rotation while unscrewing impeller.
4. Remove ceramic piece from impeller. (If you are replacing the seal)
5. Detach bracket from motor.
6. Remove carbon-graphite seal from bracket by pressing out from the back. Do not dig out from the front! (If you are replacing the seal)
Reliability You Can Count On!
© 2010 EasyPro, Inc
Pg. 3
EX8800 • EX11200 • EX13200
MAINTENANCE
Lubrication
Motor - permanently lubricated ball bearings - no service required.
Rotary Seal - requires no lubrication after assembly.
*The pump must be drained before servicing or if stored below freezing temperatures. Periodic replacement of seals may be required due to normal carbon wear.
Symptom
No Flow
Low Flow
Sporadic Operation
Problem
Insuffi cient Prime
Insuffi cient Power
Flow Restriction
Air leak
System Incompatibility
Air leak
System Incompatibility
Insuffi cient Power
Flow Restriction
Insuffi cient Prime
Cavitation
Insuffi cient Power
Resolution
Prime system with water and purge all air from suction piping.
Install check valve.
Verify power supply and connection from panel to pump.
Verify proper voltage. Some models are dual voltage (115/230).
Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted fl ow.
Clean out leaves or other debris from basket strainer (if applicable).
Fix air leaks at fi ttings, connections, strainer basket etc. This typically occurs on the intake side.
Verify hydraulic compatibility: i.e. pump & pipe are sized for the system.
Fix air leaks at fi ttings, connections, strainer basket etc. This typically occurs on the intake side.
Verify hydraulic compatibility: i.e. pump & pipe are sized for the system.
Verify power supply and connection from panel to pump.
Verify proper voltage. Some models are dual voltage (115/230).
Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Clean out leaves or other debris from basket strainer (if applicable).
Prime system with water and purge all air from suction piping.
Verify airtight plumbing on the suction plumbing especially fi ttings!
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.
Verify power supply and connection from panel to pump.
Verify proper voltage. Some models are dual voltage (115/230).
Poor Ventilation
Excessive Noise
Cavitation
Insuffi cient Power
Flow Restriction
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.
Verify power supply and connection from panel to pump.
Verify proper voltage. Some models are dual voltage (115/230).
Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted fl ow.
EASYPRO LIMITED WARRANTY
This product is warranted to the initial purchaser to be free of defects in materials and workmanship at the time of initial purchase and for a period of three years. In the event this product malfunctions within three years from the date of purchase, the sole obligation of EasyPro, Incorporated (hereinafter referred to as EP) will be to repair the unit or replace with an equivalent new or factory refurbished unit at EP’s discretion, subject to the following conditions:
1. You MUST call EP for a return authorization (RA#) number prior to returning, pumps returned without an RA# will be refused.
2. The malfunction is proved attributable to a defect in materials or workmanship, including repairs performed under this warranty. Malfunction for any other reason — including but not limited to misuse, negligence, accident, tampering with parts, incorrect wiring, improper installation — will not be remedied under this warranty.
3. EP specifi cally does not guarantee chemical compatibility, and expressly does not warrant units from any problems caused by chemical attack or failure due to incompatibility of fl uid being pumped with pump materials of construction.
4. All warranty repairs must be performed by EP or an EP authorized company. Purchaser must retain the purchase receipt and present it with this certifi cate as proof of ownership and entitlement to warranty repairs. Unauthorized repairs will not be compensated by EP, are not the responsibility of EP, and if such repairs damage the product, such damages are not remedied under this warranty.
5. Purchaser shall bear all shipping, packing and insurance costs and all other costs, excluding labor and parts necessary to effectuate repairs under this warranty.
6. Periodic check-ups are not covered by this warranty.
7. This warranty is in lieu of all other express warranties which now or hereafter might otherwise arise with respect to this product. Any and all limited warranties, including the warranties of merchantability and fi tness for particular purpose, shall have no greater duration than the duration period of the express written warranty applicable to this product, and shall terminate automatically the expiration of such duration period. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. No action shall be brought for breach of any implied or express warranty after one year subsequent to the expiration of the duration period of the express written warranty.
8. Incidental and consequential damages caused by malfunction, defect, or otherwise, and with respect to breach of any express or implied warranty, are not the responsibility of EP, and, to the extent permitted by law, are hereby excluded both for property damage and, to the extent not unconscionable, for personal injury damage. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
9. This warranty does not apply to any malfunction arising out of any application of this product other than normal use, unless such application is upon request specifi cally approved in writing by EP.
10. The provisions of this warranty are severable and if any provision shall be deemed invalid, the remaining provisions shall remain in full force and effect.
11. Rights under this warranty are not assignable without the express prior consent in writing by EP and, regardless of the terms of such consent in writing, such assignee shall have no greater rights than his assignor had against EP.
Name: ________________________________________
Address: ______________________________________
City: _______________ State: _____ Zip: __________
Model: _______ Serial Number: __________________
Date purchased: ______Where purchased: ________
Activate your warranty by fi lling out this form and mailing to EasyPro Pond Products
EasyPro Pond Products
4385 East 110th, Grant, MI 49327
800-448-3873 • 231-834-5537 fax www.EasyProPondProducts.com
Gasgacinch ® is a registered trademark of Porter Manufacturing. Noryl ® is a registered trademark of the
General Electric Company. Tefl on ® is a registered trademark of DuPont Company.
11-10
Reliability You Can Count On!
© 2010 EasyPro, Inc
Pg. 4
advertisement
Key Features
- Max Flow (gph)
- Max Head (feet)
- Max Power (watts)
- Max Current (amps)
- Motor HP
- Motor Enclosure
- Impeller