Read/Write Devices – Read/Write Antennas
5.5
SLG 75
Application area SLG 75
The SLG 75 ANT is a read/write device in the middle of the performance range. It can only be used with ANT 1, ANT 12, ANT 18 and ANT 30. The antennas can be very easily positioned for any application.
The cable between the antenna and evaluation unit is 3 m long. The length cannot be changed.
The antenna cable can be connected on the SLG side.
The SLG 75 can be used with the following interface modules:
ASM 400, ASM 410, ASM 424, ASM 450, ASM 452, ASM 454, ASM 470,
ASM 473 und ASM 475.
Areas of application of the antennas
Figure 5-16 Read/write device SLG 75
ANT 1
Figure 5-17 ANT 1 for SLG 75
The ANT 1 is an antenna in the middle of the performance range which is very useful in production plants and assembly lines because of its easily handled housing.
The antenna’s dimensions make it possible to read/write large volumes of data from/to the MDS during operation. The antenna cable can be connected on the SLG side.
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618 5-15
Read/Write Devices – Read/Write Antennas
ANT 12
Figure 5-18 ANT 12 for the SLG 75
The ANT12 is intended primarily for tool identification. The very small size of the antenna permits very accurate positioning using the plastic nuts included with it. The antenna cable can be connected on the SLG side. Data carrier communication is only possible with the MDS E623 (tool pill) in static mode.
ANT 18
Figure 5-19 ANT 18 for the SLG 75
The ANT 18 was designed primarily for use in small assembly lines. The small, compact dimensions of the antenna with its two plastic nuts (included with the product) make it easy to position for any application. The antenna cable can be connected on the SLG side. Data carrier communication is only possible with the MDS E624 in static mode.
ANT 30
5-16
Figure 5-20 ANT 30 for the SLG 75
The ANT 30 was designed primarily for use in small assembly lines. The maximum read/write range is approximately 60% greater than the ANT 18.
The compact dimensions of antenna with its two plastic nuts (included with the product) make it very easy to position for any application. The antenna cable can be connected on the SLG side. Data carrier communication is only possible with the MDS E624 in static mode.
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618
Read/Write Devices – Read/Write Antennas
Ordering data
Technical data
Table 5-11 Ordering data for the SLG 75 and ANT xx
SLG 75 write/read device with RS 422 serial interface
The antenna is not included with the
SLG 75 and must be ordered separately.
Antennas:
ANT 1 75 x 75 x 20 (L x W x H)
ANT 12 M12 x 1.0 x 40 (
∅
x wght x L)
ANT 18 M18 x 1.0 x 55 (
∅
x wght x L)
ANT 30 M30 x 1.5 x 58 (
∅
x wght x L)
SLG connector and plug-in line
6GT2 398-1AF00
6GT2 398-1CB00
6GT2 398-1CC00
6GT2 398-1CA00
6GT2 398-1CD00
See Section 3.7
Table 5-12 Technical data of the SLG 75
(read/write device)
Inductive interface to MDS
ANT-MDS read/write distances
Transmission frequency
Serial interface to ASM
Data transmission speed
Line length (ASM - SLG), max.
(for 24 VDC and a cross-section of
0.2 mm 2 )
Max. data cable length.
(See cable configuration in Table 3-13.)
MDS addressing command
SLG 75
See field data
13.56 MHz
RS 422
19200 Baud
120 m
1000 m
Direct access via addresses
Initialize MDS, read data from MDS, write data to MDS
Supply voltage (via serial interface)
Nominal value
Permissible range
24 VDC
20 to 30 VDC
Current consumption
Switch-on current (brief)
Operation (at 24 VDC)
MTBF (at +40 ° C)
Max. of 700 mA
180 mA (typical)
2.5 x 10 5 hours
Housing
Dimensions (in mm)
Electronics w/o connectors (L x W x H) 160 x 80 x 40
Color
Material
Connector
Data
Anthracite
Plastic (PA 12)
6-pin SLG connector in accordance with
DIN 43 651 (pin, device side)
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618 5-17
Read/Write Devices – Read/Write Antennas
Table 5-12 Technical data of the SLG 75
(read/write device)
Protection rating in accordance with
EN 60 529
Shock in accordance with
EN 60 721-3-7/class 7M2
Vibration in accordance with
EN 60 721-3-7/class 7M2
Mounting of SLG
Tightening torque at room temperature
Ambient temperature
During operation
During transportation and storage
Weight (approx.)
Certification
SLG 75
IP 65
30 g 1
1 g (3 to 200 Hz) 1
1.5 g (200 to 500 Hz) 1
2 M5 screws
3 Nm
–25 ° C to + 70 ° C
–40 ° C to + 85 ° C
520 g
CE, UL/CSA, FCC
1 Warning: The values for shock and vibration are maximum values and must not occur continuously.
5-18
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618
Read/Write Devices – Read/Write Antennas
Table 5-13 Technical data of the antennas
Antenna
Write/read distance, max. ANT-MDS (S g
)
Housing, dimensions in mm
Color
Material
Connector
ANT 1
100 mm
75 x 75 x 20
(L x W x H)
Anthracite
ANT 12
5 mm
M12 x 1.0 x 40
(
∅
x wght x L)
Pastel turquoise
Plastic (PA 12) Plastic
Crastin
4-pin pin, antenna side
3 m
IP 67 IP 67 (front)
ANT 18
15 mm
M18 x 1.0 x 55
(
∅
x wght x L)
ANT 30
24 mm
M30 x 1.5 x 58
(
∅
x wght x L)
Antenna line length
Protection rating in accordance with
EN 60 529
Shock in accordance with
EN 60 721-3-7/class 7M2
Vibration in accordance with
EN 60 721-3-7/class 7M2
Mounting of antenna
30 g
1 g
1
(3 to 200Hz)
2 M5 screws
1
1.5 g (200 to 500 Hz) 1
2 plastic nuts
M12 x 1.0
2 plastic nuts
M18 x 1.0
2 plastic nuts
M30 x 1.5
Ambient temperature
During operation
During transportation and storage
MTBF (at +40
°
C)
Weight (approx.)
–25
°
C to +70
°
C
–40
°
C to +85
°
C
2.5 x 10
5
hours
80 g 45 g 120 g 150 g
1 Warning: The values for shock and vibration are maximum values and must not occur continuously.
Field data
Table 5-14 Field data of the SLG 75 with antenna
SLG 75
Working distance (S a
)
Limit distance (S g
)
Diameter of the transmission window
(L d
)
Minimum distance from SLG to
SLG (D)
ANT 1
0 to 70 mm
100 mm
Depends on
MDS
800 mm
ANT 12
0 to 4 mm
5 mm
8 mm
80 mm
ANT 18
0 to 8 mm
15 mm
Depends on
MDS
125 mm
ANT 30
0 to 18 mm
24 mm
14 mm
200 mm
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618 5-19
Read/Write Devices – Read/Write Antennas
Transmission window
Transmission window:
The antenna of the MDS must be positioned inside this field to ensure reliable data communication.
MDS
Transmission window
S a
S g
Side view
Top view
L (S a,max
) = L d
L (S a,min
) 1
Figure 5-21 Transmission window of the ANT 1
1 The transmission window can be larger at S a, min
.
L d
Transmission window s a s g
L d
Top view
Side view
Figure 5-22 Transmission window of the ANT12
5-20
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618
Read/Write Devices – Read/Write Antennas
L d L (S a, min
) 1
L d s g s a
Top view
Side view 1 The transmission window can be larger when S a, min
Figure 5-23 Transmission window of the ANT18
L d
Transmission window
L d s a s g
Top view
Side view
Figure 5-24 Transmission window of the ANT 30
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618 5-21
Read/Write Devices – Read/Write Antennas
Metal-free space
Metal-free space with flush mounting a = 40 mm
Metal a
5-22 a a a h = 20 mm (non-metallic base)
Figure 5-25 Metal-free space for the ANT 1
MOBYE
ANT 12
Top view
Note:
Flush installation in metal reduces the limit and working distance.
Figure 5-26 Metal-free space for the ANT12
Side view a
MOBY E
ANT 18 a = 10 mm b = 10 mm
Metal-free space with flush installation
10
Note:
The limit and working distances are reduced when the metal-free space is not adhered to.
Figure 5-27 Metal-free space for the ANT 18
ANT 18
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618
Read/Write Devices – Read/Write Antennas
20
20
MOBYE
ANT 30
Side view
Top view
Figure 5-28 Metal-free space for the ANT 30
FCC information
Made in Germany
SIEMENS MOBY E SLG 75
FCC ID: NXWMOBYE-SLG75
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES: OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED; INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
Note
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment:
Such modifications could void the user’s authority to operate the equipment.
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618 5-23
Read/Write Devices – Read/Write Antennas
Definition of the distance D
ANT 1
ANT 1
Figure 5-29 Distance D: ANT 1
D a
D b
D a
ANT 1
D a
D b
> 800 mm
> 800 mm
D b
Figure 5-30 Distance D: ANT 12
D a
D b
80 mm
80 mm
The SLG electronics can be mounted directly next to each other.
5-24
D a
D b
D a
D b
125 mm
125 mm
The SLG electronics can be mounted directly next to each other.
Figure 5-31 Distance D: ANT 18
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618
Read/Write Devices – Read/Write Antennas
D a
D b
Figure 5-32 Distance D: ANT 30
D a
D b
200 mm
200 mm
The SLG electronics can be mounted directly next to each other.
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618 5-25
Read/Write Devices – Read/Write Antennas
Dimensions
(in mm)
5
80 40
5-26
160
5.5
25
5
Figure 5-33 Dimensioned drawing of SLG 75
Cable length 3 m
Minimum bending radius: 20 mm
ANT 1 can be connected on electronics side
Figure 5-34 Dimensioned drawing of the ANT 1
5
75
20
40
Cable length 3 m
Minimum bending radius: 20 mm
Antenna head
ANT 12 can be connected on electronics side
Figure 5-35 Dimensioned drawing of the ANT 12
Antenna side
MOBY E
ANT 12
17
Side view of the antenna head
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618
Read/Write Devices – Read/Write Antennas
55
Cable length 3 m
Minimum bending radius: 20 mm
Antenna head
ANT 18 can be connected on electronics side
Figure 5-36 Dimensioned drawing of the ANT 18
Antenna side
MOBY E
ANT 18
24
Side view of the antenna head
58
Cable length 3 m
Minimum bending radius: 20 mm
Antenna head
ANT 30 can be connected on electronics side
Figure 5-37 Dimensioned drawing of the ANT 30
Antenna side
MOBY E
ANT 30
43
Side view of the antenna head
Note
The length of the line between antenna and evaluation unit is 3 m. The length cannot be changed.
Caution
The antenna must not be removed in an energized state.
MOBY E Configuration, Installation and Service Manual
(4) J31069-D0105-U001-A5-7618 5-27